System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family

Table Of Contents

System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family

AAA Messages

AAA-1

AAA-2

AAA-3

AAA-6

AAM Messages

AAM-2

AAM-3

ACLLOG Messages

ACLLOG-4

ACLLOG-6

ACLMGR Messages

ACLMGR-2

ACLMGR-3

ACLMGR-4

ACLMGR-6

ACLQOS Messages

ACLQOS-SLOT#-2

ACLQOS-SLOT#-3

ACLQOS-SLOT#-4

ACLQOS-SLOT#-5

ACLTCAM Messages

ACLTCAM-2

ACLTCAM-3

ACLTCAM-4

ACLTCAM-6

ACL Messages

ACL-2

ACL-4

ACL-5

ACL-6

ASCII-CFG Messages

ASCII-CFG-2

ASCII-CFG-3

ASCII-CFG-6

BIOS DAEMON Messages

BIOS DAEMON-2

BIOS_DAEMON-SLOT#-2

BOOTUP TEST Messages

BOOTUP TEST-2

BOOTVAR Messages

BOOTVAR-2

BOOTVAR-3

BOOTVAR-5

BOOTVAR-6

CALLHOME Messages

CALLHOME-2

CALLHOME-3

CALLHOME-6

CDP Messages

CDP-2

CDP-3

CDP-4

CDP-5

CDP-6

CERT_ENROLL Messages

CERT_ENROLL-2

CERT_ENROLL-3

CERT_ENROLL-6

CFS Messages

CFS-2

CFS-3

CFS-4

CFS-6

CIMSRVPROV Messages

CIMSRVPROV-2

CIMSRVPROV-3

CIMSRVPROV-6

CLIS Messages

CLIS-5

CLOUD Messages

CLOUD-2

CLOUD-3

CLOUD-6

CLUSTER Messages

CLUSTER-2

CMPPROXY Messages

CMPPROXY-2

CMPPROXY-5

CMPPROXY-6

COPP Messages

COPP-2

COPP-3

COPP-5

COPP-6

CORE-DMON Messages

CORE-DMON-2

CORE-DMON-3

CPPA_MGR Messages

CPPA_MGR-3

CPPA_MGR-5

CREDITMON Messages

CREDITMON-SLOT#-2

CTS Messages

CTS-2

CTS-3

CTS-5

DEBUGPROXY Messages

DEBUGPROXY-6

DEVICE-ALIAS Messages

DEVICE-ALIAS-2

DEVICE-ALIAS-3

DEVICE-ALIAS-6

DEVICE_TEST Messages

DEVICE_TEST-2

DEVICE_TEST-3

DEVICE_TEST-4

DEVICE_TEST-5

DEVICE_TEST-6

DEV_LOG Messages

DEV_LOG-3

DEV_LOG-SLOT#-4

DFTM Messages

DFTM-3

DHCP_SNOOP Messages

DHCP_SNOOP-2

DHCP_SNOOP-3

DHCP_SNOOP-4

DHCP_SNOOP-6

DIAGCLIENT Messages

DIAGCLIENT-2

DIAGCLIENT-3

DIAGCLIENT-4

DIAGCLIENT-5

DIAGMGR Messages

DIAGMGR-2

DIAGMGR-3

DIAGMGR-4

DIAGMGR-5

DIAGMGR-6

DIAG_PORT_LB Messages

DIAG_PORT_LB-2

DIAG_PORT_LB-3

DIAG_PORT_LB-5

DMM Messages

DMM-SLOT#-5

DOT1X Messages

DOT1X-2

DOT1X-3

DOT1X-4

DOT1X-5

DPP_DEBUG Messages

DPP_DEBUG-2

DPVM Messages

DPVM-2

DPVM-3

DPVM-4

DPVM-6

DSTATS Messages

DSTATS-2

DSTATS-3

ELTMC Messages

ELTMC-SLOT#-2

ELTM Messages

ELTM-2

ELTM-6

EOU Messages

EOU-2

EOU-5

EOU-6

EOU-7

EPP Messages

EPP-5

ETH-PORT-SEC Messages

ETH-PORT-SEC-2

ETH-PORT-SEC-3

ETH-PORT-SEC-5

ETHPORT Messages

ETHPORT-2

ETHPORT-3

ETHPORT-4

ETHPORT-5

ETH_PORT_CHANNEL Messages

ETH_PORT_CHANNEL-1

ETH_PORT_CHANNEL-2

ETH_PORT_CHANNEL-3

ETH_PORT_CHANNEL-4

ETH_PORT_CHANNEL-5

ETH_PORT_CHANNEL-6

ETH_PORT_CHANNEL-7

EUREKA_USD Messages

EUREKA_USD-3

EVMC Messages

EVMC-5

EVMS Messages

EVMS-2

EVMS-4

EXCEPTIONLOG Messages

EXCEPTIONLOG-SLOT#-2

FC-TUNNEL Messages

FC-TUNNEL-3

FC-TUNNEL-5

FCC_LC Messages

FCC_LC-2

FCC_LC-5

FCC-5

FCC-6

FCDDH Messages

FCDDH-SLOT#-3

FCDDH-SLOT#-4

FCDDH-SLOT#-5

FCDD Messages

FCDD-SLOT#-3

FCDD-SLOT#-4

FCDD-SLOT#-5

FCDD-SLOT#-7

FCDOMAIN Messages

FCDOMAIN-2

FCDOMAIN-3

FCDOMAIN-4

FCDOMAIN-5

FCDOMAIN-6

FCDOMAIN-7

FCFWD Messages

FCFWD-3

FCFWD-4

No action is required.

FCNS Messages

FCNS-2

FCNS-3

FCNS-4

FCNS-6

FCSP-MGR Messages

FCSP-MGR-2

FCS Messages

FCS-2

FCS-3

FCS-4

FCS-5

FCS-6

FDMI Messages

FDMI-2

FDMI-3

FDMI-4

FDMI-6

FEATURE-MGR Messages

FEATURE-MGR-2

FICON Messages

FICON-2

FICON-3

FICON-5

FICON-6

FLOGI Messages

FLOGI-1

FLOGI-2

FLOGI-4

FLOGI-5

FS-DAEMON Messages

FS-DAEMON-2

FS-DAEMON-6

FSCM Messages

FSCM-2

FSPF Messages

FSPF-2

FSPF-3

FSPF-4

FSPF-5

FSPF-6

FSPF-7

FWM Messages

FWM-0

FWM-1

FWM-2

FWM-3

FWM-4

FWM-6

GLBP Messages

GLBP-2

GLBP-3

GLBP-4

GLBP-5

HSRP_ENGINE Messages

HSRP_ENGINE-3

HSRP_ENGINE-4

HSRP_ENGINE-6

IKE Messages

IKE-3

IKE-4

IKE-6

ILC-SPAN Messages

ILC-SPAN-3

ILC_HELPER Messages

ILC_HELPER-2

ILC_HELPER-3

ILC_HELPER-6

IMAGE_DNLD Messages

IMAGE_DNLD-SLOT#-2

IMAGE_DNLD-SLOT#-4

IMAGE_DNLD-SLOT#-5

IMAGE_UPGRADE Messages

IMAGE_UPGRADE-SLOT#-2

IMAGE_UPGRADE-SLOT#-4

IM Messages

IM-3

IM-5

INTERFACE_VLAN Messages

INTERFACE_VLAN-5

IOA_LC Messages

IOA_LC-5

IPACL Messages

IPACL-0

IPACL-1

IPACL-2

IPACL-4

IPACL-5

IPACL-6

IPFC Messages

IPFC-2

IPFC-3

IPFC-5

IPFC-6

IPPOOL Messages

IPPOOL-3

IPPOOL-5

IPQOSMGR Messages

IPQOSMGR-2

IPQOSMGR-3

IPQOSMGR-4

IPQOSMGR-6

IPQOSMGR-SLOT#-3

IPSEC Messages

IPSEC-2

IPSEC-3

IPSEC-5

IPS_SB_MGR Messages

IPS_SB_MGR-SLOT#-2

IPS_SB_MGR-SLOT#-3

IPS_SB_MGR-SLOT#-4

IPS_SB_MGR-SLOT#-6

IPS Messages

IPS-2

IPS-3

IPS-4

IPS-5

IPS-7

IPV6 Messages

IPV6-2

IPV6-3

IPV6-4

IPV6-6

IP Messages

IP-2

IP-3

IP-4

IP-6

ISAPI Messages

ISAPI-SLOT#-0

ISAPI-SLOT#-1

ISAPI-SLOT#-2

ISAPI-SLOT#-3

ISAPI-SLOT#-4

ISAPI-SLOT#-5

ISAPI-SLOT#-6

ISAPI-SLOT#-7

ISNS Messages

ISNS-2

IVR Messages

IVR-2

IVR-3

IVR-4

IVR-5

IVR-6

IVR-7

L2FMC Messages

L2FMC-SLOT#-0

L2FMC-SLOT#-2

L2FMC-SLOT#-5

L2FMC-SLOT#-6

L2FM Messages

L2FM-0

L2FM-1

L2FM-2

L2FM-6

L2MCAST Messages

L2MCAST-SLOT#-0

L2MCAST-SLOT#-2

L2MCAST-SLOT#-6

LACP Messages

LACP-3

LACP-5

LC-FCFWD Messages

LC-FCFWD-3

LC-SPAN Messages

LC-SPAN-3

LC_CFG Messages

LC_CFG-SLOT#-2

LC_PORT_CHANNEL Messages

LC_PORT_CHANNEL-SLOT#-0

LC_PORT_CHANNEL-SLOT#-3

LC_PORT_MGR Messages

LC_PORT_MGR-SLOT#-2

LC_RDL Messages

LC_RDL-3

LC_RDL-6

LIBBASE_SVC Messages

LIBBASE_SVC-2

LIBBASE_SVC-5

LIBGD Messages

LIBGD-2

LIBGD-3

LIBGD-5

LIBGD-6

LICMGR Messages

LICMGR-2

LICMGR-3

LICMGR-4

LICMGR-6

LLDP Messages

LLDP-3

LLDP-5

LLDP-6

MAC Messages

MAC-SLOT#-2

MCAST Messages

MCAST-2

MCAST-4

MCAST-5

MCECTEST Messages

MCECTEST-3

MCECTEST-5

MCECTEST-6

MCM Messages

MCM-5

MFDM Messages

MFDM-2

MODULE Messages

MODULE-2

MODULE-3

MODULE-4

MODULE-5

MODULE-6

MONITOR Messages

MONITOR-3

MONITOR-5

MONITOR-6

NFM Messages

NFM-2

NFM-3

NFM-4

NFM-5

NFM-6

NFM-7

NFP Messages

NFP-SLOT#-2

NPC Messages

NPC-SLOT#-3

NPC-SLOT#-4

NPC-SLOT#-5

NPV Messages

NPV-2

NPV-3

NPV-4

NPV-5

NPV-6

NPV-7

NTP Messages

NTP-2

NTP-3

NTP-6

NVP Messages

NVP-6

NVP-SLOT#-2

OC_USD Messages

OC_USD-2

ORI_MAC Messages

ORI_MAC-6

OTM Messages

OTM-2

OTM-3

OTM-5

OTM-6

PHY_USD Messages

PHY_USD-SLOT#-4

PIXM Messages

PIXM-2

PIXM-3

PIXM-4

PLATFORM Messages

PLATFORM-0

PLATFORM-1

PLATFORM-2

PLATFORM-3

PLATFORM-4

PLATFORM-5

PLATFORM-6

PLATFORM-7

PLOG_SUP Messages

PLOG_SUP-4

PLOG Messages

PLOG-4

POLICY_ENGINE Messages

POLICY_ENGINE-5

POLICY_ENGINE-6

PORT-CHANNEL Messages

PORT-CHANNEL-1

PORT-CHANNEL-2

PORT-CHANNEL-3

PORT-CHANNEL-4

PORT-CHANNEL-5

PORT-CHANNEL-6

PORT-CHANNEL-7

PORT-PROFILE Messages

PORT-PROFILE-2

PORT-PROFILE-3

PORT-PROFILE-6

PORT-RESOURCES Messages

PORT-RESOURCES-3

PORT-RESOURCES-5

PORT-SECURITY Messages

PORT-SECURITY-2

PORT-SECURITY-3

PORT-SECURITY-4

PORT-SECURITY-6

PORT Messages

PORT-2

PORT-3

PORT-4

PORT-5

PRIVATE_VLAN Messages

PRIVATE_VLAN-3

PRIVATE_VLAN-5

PROC_MGR Messages

PROC_MGR-SLOT#-2

PROC_MGR-SLOT#-3

PROC_MGR-SLOT#-4

PROC_MGR-SLOT#-6

PSS Messages

PSS-0

PSS-1

PSS-2

PSS-4

PSS-5

QOS Messages

QOS-2

QOS-3

QOS-4

QOS-6

RADIUS Messages

RADIUS-2

RADIUS-3

RADIUS-5

RADIUS-6

RDL Messages

RDL-2

RDL-3

RDL-6

RES_MGR Messages

RES_MGR-1

RES_MGR-2

RES_MGR-3

RES_MGR-4

RES_MGR-5

RES_MGR-6

RIB Messages

RIB-0

RIB-1

RIB-2

RIB-3

RIB-4

RIB-5

RIB-6

RLIR Messages

RLIR-2

RLIR-6

RM Messages

RM-6

RM-SLOT#-2

RM-SLOT#-4

RSCN Messages

RSCN-2

RSCN-4

RSCN-6

SAL Messages

SAL-5

SAN_EXT_TUNER Messages

SAN_EXT_TUNER-3

SCHEDULER Messages

SCHEDULER-2

SCHEDULER-3

SCHEDULER-4

SCHEDULER-6

SCSI-TARGET Messages

SCSI-TARGET-2

SCSI-TARGET-3

SCSI-TARGET-7

SDV Messages

SDV-2

SDV-3

SDV-4

SDV-6

SDV-7

SECURITYD Messages

SECURITYD-2

SECURITYD-3

SECURITYD-5

SECURITYD-6

SENSOR_USD Messages

SENSOR_USD-2

SENSOR_USD-3

SENSOR_USD-5

SENSOR_MGR Messages

SENSOR_MGR-2

SENSOR_MGR-3

SENSOR_MGR-4

SFC Messages

SFC-3

SFM Messages

SFM-2

SFM-6

SKSD Messages

SKSD-5

SKT_USD Messages

SKT_USD-3

SME_CPP Messages

SME_CPP-2

SME_CPP-3

SME_CPP-5

SME_CPP-SLOT#-2

SME_CPP-SLOT#-3

SME_CPP-SLOT#-4

SNMPD Messages

SNMPD-1

SNMPD-2

SNMPD-3

SNMPD-4

SNMPD-5

SNMPD-6

SNMPD-7

SPAN Messages

SPAN-2

SPAN-3

SPAN-5

SPAN-6

SPI Messages

SPI-SLOT#-2

STP Messages

STP-2

STP-3

STP-4

STP-6

SVC_BATTERY Messages

SVC_BATTERY-SLOT#-2

SVC_BATTERY-SLOT#-4

SVC_BATTERY-SLOT#-6

SVC Messages

SVC-0

SVC-1

SVC-2

SVC-3

SVC-4

SVC-5

SVC-6

SVC-7

SYSMGR Messages

SYSMGR-2

SYSMGR-3

SYSMGR-4

SYSMGR-5

SYSMGR-6

SYSMGR-7

SYSTEMHEALTH Messages

SYSTEMHEALTH-2

SYSTEMHEALTH-4

SYSTEMHEALTH-5

SYSTEMHEALTH-6

TACACS Messages

TACACS-2

TACACS-3

TACACS-5

TACACS-6

TCAP Messages

TCAP-2

TLPORT Messages

TLPORT-2

TLPORT-3

TLPORT-4

TLPORT-6

TPC Messages

TPC-SLOT#-5

TTYD Messages

TTYD-2

TTYD-3

TTYD-6

TUNNEL Messages

TUNNEL-3

TUNNEL-4

TUNNEL-5

TUNNEL-7

UDLD Messages

UDLD-3

UDLD-4

UDLD-5

UFDM Messages

UFDM-2

VDC_MGR Messages

VDC_MGR-2

VDC_MGR-3

VDC_MGR-6

VEC Messages

VEC-SLOT#-3

VEC-SLOT#-4

VEC-SLOT#-5

VEDB_MGR Messages

VEDB_MGR-2

VEDB_MGR-6

VEM_MGR Messages

VEM_MGR-2

VEM_MGR-3

VEM_MGR-5

VEM_MGR-6

VES Messages

VES-SLOT#-4

VES-SLOT#-5

VFC Messages

VFC-3

VFC-6

VIM Messages

VIM-5

VLAN_MGR Messages

VLAN_MGR-2

VLAN_MGR-6

VMM Messages

VMM-2

VMS Messages

VMS-2

VMS-3

VMS-5

VNI Messages

VNI-2

VNI-3

VNI-6

VNS_AGENT Messages

VNS_AGENT-2

VNS_AGENT-3

VNS_AGENT-5

VNS_AGENT-6

VNS_AGENT-7

VPC Messages

VPC-2

VPC-3

VPC-4

VPC-5

VPC-6

VPM Messages

VPM-2

VPM-3

VPM-4

VPM-6

VPM-SLOT#-2

VRRP-CFG Messages

VRRP-CFG-2

VRRP-CFG-3

VRRP-CFG-5

VRRP-ENG Messages

VRRP-ENG-2

VRRP-ENG-3

VRRP-ENG-4

VRRP-ENG-5

VRRP-ENG-6

VSAN Messages

VSAN-2

VSAN-3

VSAN-6

VSD Messages

VSD-SLOT#-2

VSHD Messages

VSHD-2

VSHD-3

VSHD-4

VSHD-5

VSHD-7

WWN Messages

WWN-1

WWN-2

WWN-3

WWN-4

WWN-5

WWN-6

WWN-7

XBAR_CLIENT Messages

XBAR_CLIENT-2

XBAR_CLIENT-3

XBAR_CLIENT-SLOT#-2

XBAR_CLIENT-SLOT#-3

XBAR Messages

XBAR-2

XBAR-3

XBAR-5

XMLMA Messages

XMLMA-2

XMLMA-3

XMLMA-5

XMLMA-6

XMLSA Messages

XMLSA-2

XMLSA-5

XMLSA-6

ZONE Messages

ZONE-2

ZONE-3

ZONE-4

ZONE-5

ZONE-6


System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family


This chapter includes system messages for the Cisco NX-OS Nexus1000 and Nexus 1010 families of switches. The messages are listed in alphabetical order by the system facility that produces them. Within each system facility section, messages are listed alphabetically by severity and mnemonics. Each error message is followed by an explanation and a recommended action.

AAA Messages

This section contains the AAA messages.

AAA-1

Error Message    AAA-1-AAA_SESSION_LIMIT_REJECT: aaa request rejected as maximum aaa 
sessions are in progress 

Explanation    Aaa request rejected as the limit for maximum concurrent aaa sessions is reached

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-2

Error Message     AAA-2-AAA_NVRAM_UPGRADE_FAILURE: upgrading of accounting log failed. 
[chars] 

Explanation    Upgrading of accounting log failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     AAA-2-AAA_PROGRAM_EXIT: aaa daemon exiting: [chars] 

Explanation    Aaa daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-3

Error Message     AAA-3-AAA_NVRAMFAILURE: nvram failure 

Explanation    Nvram can not be read/written to. Hence accounting log can not be stored there

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-6

Error Message     AAA-6-AAA_ACCOUNTING_MESSAGE: [chars] 

Explanation    Accounting Message

Recommended Action    No action is required.

AAM Messages

This section contains the AAM messages.

AAM-2

Error Message    AAM-2-ELS_FC2_GL_SINDEX_LOOKUP_FAILED: Failed to lookup global port 
index for interface [[chars]] 

Explanation    Failed to lookup global port index for interface [chars]

Recommended Action    No action is required.

AAM-3

Error Message     AAM-3-ALLOC_FAILED: Failed in File:[chars] Line:[dec] for type [dec] 
size [dec] 

Explanation    AAM process could not allocate heap memory in File:[chars], at line:[dec], for memory-type:[dec] of Size:[dec]

Recommended Action    No action is required.

Error Message     AAM-3-ASSERTION_FAILED: Failed in File:[chars] Line:[dec] 

Explanation    AAM Process assertion failed in File:[chars], at line:[dec]

Recommended Action    No action is required.

ACLLOG Messages

This section contains the ACLLOG messages.

ACLLOG-4

Error Message    ACLLOG-4-ACLLOG_MAXFLOW_REACHED: [chars] 

Explanation    Max flow reached in current interval: [chars]

Recommended Action    No action is required.

Error Message     ACLLOG-4-ACLLOG_THRESHOLD: [chars] 

Explanation    Threshold Reached for Flow: [chars]

Recommended Action    No action is required.

ACLLOG-6

Error Message     ACLLOG-6-ACLLOG_FLOW_INTERVAL: [chars] 

Explanation    Flow info in current alert interval: [chars]

Recommended Action    No action is required.

Error Message     ACLLOG-6-ACLLOG_NEW_FLOW: [chars] 

Explanation    New Acllog Flow: [chars]

Recommended Action    No action is required.

ACLMGR Messages

This section contains the ACLMGR messages.

ACLMGR-2

Error Message     ACLMGR-2-ACLMGR_COMMIT_FAIL: Commit failed: client %llX, [chars] 

Explanation    The PPF commit failed

Recommended Action    No action is required.

Error Message     ACLMGR-2-ACLMGR_NO_ERRDISABLED: [chars] event on interface [chars] 
([hex]) allowed to succeed in spite of access-list failure 

Explanation    Although an access-list operation failed during a port event, the port event still finished successfully because errdisable is disallowed

Recommended Action    No action is required.

Error Message     ACLMGR-2-EXITING: Exit reason: [chars] 

Explanation    The ACLMGR service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     ACLMGR-2-INITFAIL: ACLMGR Service Init failed: [chars] 

Explanation    ACLMGR Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     ACLMGR-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The ACLMGR service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     ACLMGR-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The ACLMGR service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

ACLMGR-3

Error Message    ACLMGR-3-ACLMGR_ACL_ON_FAB_INACTIVE: ACL on FEX fabric interface not 
activated 

Explanation    ACL applied to a FEX fabric port or port-channel is not activated

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_ACL_OVER_FAB_CHANNEL: ACL on FEX fabric port-channel 
bound interface not activated 

Explanation    ACL applied to a FEX interface is not activated if the interface is bound to a FEX-fabric portchannel

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_PPF_ERROR: PPF error: [chars] 

Explanation    The PPF generated error

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The ACLMGR service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_STAT_CONSOLIDATION_FAILURE: ACL statistic parsing or 
consolidation failed 

Explanation    A statistic update failed during the parsing or consolidation step; statistics may have been lost

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_VACL_REDIRECTION_DISABLED_REMOVAL: VACL redirection 
to interface [chars] ([hex]) disabled: the port has been removed 

Explanation    A VACL redirection to the port has been deactivated because the port has been removed

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_VERIFY_FAIL: Verify failed: client %llX, [chars] 

Explanation    The PPF Verify failed

Recommended Action    No action is required.

Error Message     ACLMGR-3-MTSERROR: [chars] 

Explanation    ACLMGR Service encountered an MTS error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

ACLMGR-4

Error Message     ACLMGR-4-ACLMGR_PPF_WARNING: PPF warning: [chars] 

Explanation    The PPF generated warning

Recommended Action    No action is required.

Error Message     ACLMGR-4-ACLMGR_VACL_REDIRECTION_DISABLED_PCM: VACL redirection to 
interface [chars] ([hex]) disabled: the port became a portchannel member 

Explanation    A VACL redirection to the port has been temporarily deactivated because it is now a member in a port channel

Recommended Action    No action is required.

Error Message     ACLMGR-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the ACLMGR service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

ACLMGR-6

Error Message     ACLMGR-6-ACLMGR_PPF_NOTIF: PPF notification: [chars] 

Explanation    The PPF generated notification

Recommended Action    No action is required.

Error Message     ACLMGR-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The ACLMGR service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     ACLMGR-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The ACLMGR service became standby from active mode.

Recommended Action    No action is required.

Error Message     ACLMGR-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The ACLMGR service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     ACLMGR-6-SERVICE_UP: Initialized [chars] 

Explanation    The ACLMGR service is up and ready The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     ACLMGR-6-SRVEXIT: ACLMGR Service shutting down gracefully 

Explanation    ACLMGR Service is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     ACLMGR-6-SWITCHOVER: Switching Over to other Sup. 

Explanation    The ACLMGR service has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

ACLQOS Messages

This section contains the ACLQOS messages.

ACLQOS-SLOT#-2

Error Message    ACLQOS-SLOT#-2-ACLQOS_FAILED: ACLQOS failure: [chars] 

Explanation    ACLQOS operation failed in the aclqos client

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_INBAND_INTERFACE_FAILURE: Inband interface lif 
lookup failed ([chars]) 

Explanation    Inband interface lif lookup failed

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_MALLOC_FAILED: Memory allocation failed. 
[chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_OOTR: Tcam resource exhausted: [chars] 

Explanation    Tcam resources to program acls exhausted

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-PPF_FAILED: Database failure: [chars] 

Explanation    Database operation failed in the aclqos client

Recommended Action    No DDTS.

ACLQOS-SLOT#-3

Error Message     ACLQOS-SLOT#-3-ACLQOS_CC_INVALID: Invalid Congestion Control 
parameters 

Explanation    Invalid Congestion Control parameters

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-3-ACLQOS_PAUSE_INVALID: Invalid Pause parameters 

Explanation    Invalid Pause parameters

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-3-ACLQOS_QUEUING_ERROR: ACL/QoS queuing error: [chars] 

Explanation    Internal error in ACL/QoS queuing config

Recommended Action    No DDTS.

ACLQOS-SLOT#-4

Error Message     ACLQOS-SLOT#-4-ACLQOS_ATOMIC_ERR: [chars] 

Explanation    Tcam will be overused, please turn off atomic update

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_MATCH_ALL_MERGE_UPDATE: Warning (match_all 
merging): [chars] 

Explanation    Warning (match_all merging)

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_OVER_THRESHOLD: Tcam [dec] Bank [dec]'s usage 
has reached its threshold 

Explanation    Tcam is almost full

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_QUEUING_COS2Q_INVALID: ACL/QoS invalid queuing 
policy because of cos map change: [chars] queue [chars], interface [chars] 

Explanation    Attemped to configure an invalid queuing policy

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_QUEUING_INVALID: ACL/QoS invalid queuing 
policy: [chars] 

Explanation    Attemped to configure an invalid queuing policy

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_UNDER_THRESHOLD: Tcam [dec] Bank [dec]'s usage 
is below the threshold now 

Explanation    Tcam's usage is below the threshold

Recommended Action    No DDTS.

ACLQOS-SLOT#-5

Error Message     ACLQOS-SLOT#-5-ACLQOS_DISRUPTIVE_IPv6_UPDATE: Disruptive update of 
IPv6 compression entries 

Explanation    Disruptive IPv6 compression entries update

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-5-ACLQOS_NON_ATOMIC: Non atomic ACL/QoS policy update 
done for [chars] 

Explanation    Non atomic ACL/QoS policy update was done

Recommended Action    No DDTS.

ACLTCAM Messages

This section contains the ACLTCAM messages.

ACLTCAM-2

Error Message    ACLTCAM-2-ACL_TCAM_ADJ_EXHAUSTED: ACLTCAM failed to program route for 
VSAN: [dec], SID: [chars] DID: [chars], error: [chars].

Explanation    ACLTCAM process experienced a failure while programming route for VSAN [dec] SID [chars] DID [chars] due to resource exhaustion. [chars] is the error code.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_ALMOST_FULL: TCAM close to FULL. [chars] TCAM 
Usage ([dec]/[dec]) exceeded [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_CONFIG_READ_FROM_DRIVER_FAILED: [chars] [dec], 
Error: [hex]. 

Explanation    Unable to read configuration from forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_CONFIG_WRITE_TO_DRIVER_FAILED: [chars] [dec], 
Error: [hex]. 

Explanation    Unable to write configuration to forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INCONSISTENT_DATABASE: Database found 
inconsistent. 

Explanation    Database found inconsistent.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INCONSISTENT_TCAM_CONTENTS: TCAM contents found 
inconsistent. 

Explanation    TCAM contents are found inconsistent.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INIT_FAILED: Initialization failed for forwarding 
engine ASIC: [dec], [chars] TCAM. 

Explanation    Initialization failed for forwarding engine ASIC [dec], in [chars] TCAM.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INIT_REGIONS_FAILED: Initialization failed for 
forwarding engine ASIC: [dec], [chars] TCAM, [chars] Region. 

Explanation    Initialization of regions failed for forwarding engine ASIC [dec], in [chars] TCAM, for [chars] Region.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_MALLOC_FAILURE: Memory allocation failed for size 
[dec]. 

Explanation    Memory allocation is failed for size [dec] bytes.

Recommended Action    Restart the process.

Error Message     ACLTCAM-2-ACL_TCAM_MTS_FAILURE: MTS operation failed: [chars]. 

Explanation    MTS operation failed. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_MTS_REGISTRATION_FAILED: MTS registration failed 
for opCode: [dec]. 

Explanation    MTS registration failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_NO_ROUTE: ACLTCAM failed to get route for VSAN: 
[dec], Rewrite: [chars] DID: [chars] DID MASK: [chars], error: [hex].

Explanation    ACLTCAM process experienced a failure while getting route for VSAN [dec] Rewrite [chars] DID [chars] DID Mask [chars]. [hex] is the error code.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_NO_TCAM_LEFT: ACLTCAM resource exhausted for 
interface : [chars] 

Explanation    ACLTCAM hardware resource is completely used.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_FAILED: [chars] read from hardware 
TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: 
[chars]).

Explanation    [chars] read from hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_INVALID: Invalid([chars], value: 
[dec]) TCAM entry read from hardware TCAM (FWD-Engine: [dec], [chars] TCAM, 
Address: [dec]), Ignoring this entry.

Explanation    Invalid([chars], value: [dec]) TCAM entry from hardware TCAM(FWD-Engine: [dec], [chars] TCAM, Address: [dec]) Ignoring this entry

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_WRITE_FAILED: [chars] write to hardware 
TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: 
[chars]).

Explanation    [chars] write to hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PSS_FAILURE: Failed to do PSS operation: [chars], 
reason: [hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-PSS_OPEN_FAILED: PSS open failed - [hex]. 

Explanation    Persistent database handle could not obtained for ACLTCAM. [hex] is the error.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-RECONS_FAILED: Reconstruction of TCAM contents failed 
during upgrade - [hex]. 

Explanation    During non-disruptive upgrade, the ACLTCAM contents are not properly reconstructed. [hex] is the error.

Recommended Action    No action is required.

ACLTCAM-3

Error Message     ACLTCAM-3-REGISTER_FAILED: Could not register to MTS opcode [chars] 
- error [hex]. 

Explanation    ACLTCAM process could not register to the notifications mentioned by [chars]. [hex] is the error.

Recommended Action    No action is required.

ACLTCAM-4

Error Message     ACLTCAM-4-ACL_TCAM_BELOW_THRESHOLD: [chars] TCAM usage ([dec]/[dec]) 
fell below [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] fell below [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_BEYOND_THRESHOLD: [chars] TCAM usage ([dec]/[dec]) 
exceeded [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_INVALIDATED: Flow counter for flow: 
vsan: [dec], sid: [hex], did: [hex] with statistics: frames = %llu & bytes = %llu 
was invalidated due to: [chars]

Explanation    ACLTCAM process invalidated the flow counter for flow VSAN [dec] SID [hex] DID [hex] with collected stats of [dec] frames and [dev] bytes was invalidated because of reason [[chars]].

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_VALIDATED: Flow counter for flow: 
vsan: [dec], sid: [hex], did: [hex] is now valid

Explanation    ACLTCAM process validated the flow counter for flow VSAN [dec] SID [hex] DID [hex].

Recommended Action    No action is required.

ACLTCAM-6

Error Message     ACLTCAM-6-ACL_TCAM_STATUS: Status: [chars]. 

Explanation    ACLTCAM status is reported as: [chars].

Recommended Action    No action is required.

ACL Messages

This section contains the ACL messages.

ACL-2

Error Message    ACL-2-ACL_HA_FAILURE: Failed to do high availability operation: 
[chars]. 

Explanation    Failed to do high availability operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_INIT_FAILED: Initialization failed for ACL: [chars], 
reason: [hex]. 

Explanation    Initialization failed for ACL due to [chars], reason: [hex].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_LINECARD_STATUS: Status from linecard: [dec], for module: 
[chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], 
restart count: [dec].

Explanation    Status from linecard: [dec], for module: [chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], restart count: [dec].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_MTS_FAILURE: Failed to do MTS operation: [chars]. 

Explanation    Failed to do MTS operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_MTS_REGISTRATION_FAILED: MTS options setting to [hex] 
failed for opCode: [dec]. 

Explanation    MTS options setting to [hex] failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PENDING_MSG_ARR_FULL: ACL Upgrade Pending Messages Array is 
Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]

Explanation    ACL Upgrade Pending Messages Array is Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PSS_FAILURE: Failed to do PSS operation: [chars], reason: 
[hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec]. 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_RUNTIME_FAILURE: [chars] [dec], Error: [hex] 

Explanation    ACL runtime failure is reported as [chars] [dec], reason: [hex].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_TCAM_FAILURE: Failed to do TCAM operation: [chars]. 

Explanation    Failed to do TCAM operation. [chars] is the reason.

Recommended Action    No action is required.

ACL-4

Error Message     ACL-4-ACL_WARNING: [chars] [dec] 

Explanation    ACL warning messages is reported as [chars] [dec].

Recommended Action    No action is required.

ACL-5

Error Message     ACL-5-ACL_ADJ_SHARING_STATUS: Successfully completed [chars] on 
Generation 2 linecards. 

Explanation    Successfully completed the command \[chars]\ on Generation 2 linecards.

Recommended Action    No action is required.

ACL-6

Error Message     ACL-6-ACL_DIAG_EVENT_STATUS: [chars] [hex]. 

Explanation    ACL system health management event status is reported as [chars] [hex].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_E_PORT_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL xEport event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_FCC_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL FCC event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_LINECARD_EVENT_STATUS: [chars] [hex]. 

Explanation    ACL linecard event status is reported as [chars] [dec].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_MCAST_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL multicast event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_NX_PORT_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL Nx Port event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_PORT_MODE_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL portmode event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_RUNTIME_STATUS: [chars] [dec] 

Explanation    ACL runtime status is reported as [chars] [dec].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_SPAN_DEST_CONFIG_STATUS: [chars] [chars]. 

Explanation    ACL SPAN destination config event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_SPAN_SRC_CONFIG_STATUS: [chars] [chars]. 

Explanation    ACL SPAN source config event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_STATUS: ACL Status: [chars]. 

Explanation    ACL status is reported as [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_UPDATE_SSRAM_QOS_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL update SSRAM for QoS event status is reported as [chars] [chars].

Recommended Action    No action is required.

ASCII-CFG Messages

This section contains the ASCII-CFG messages.

ASCII-CFG-2

Error Message    ASCII-CFG-2-ACFG_CONFIGURATION_APPLY_ERROR: Error encountered while 
Ascii configuration was being applied. Please use show startup-config log to view 
details

Explanation    At least one command failed while Ascii configuration was being applied

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_LIB_INVOKE_ERR: Ascii config library invocation 
error: [chars] 

Explanation    Error encountered while library function was being invoked to display Ascii configuration

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_OPER_FAIL: Operation failed because of [chars] 

Explanation    Operation failed

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_ROLLBACK_FAILED: Rollback to checkpoint [chars] 
Failed, Going to undo the changes (atomic option) 

Explanation    Rollback operation failed for atomic option

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_ROLLBACK_UNDO_FAILED: Undo failed for atomic 
Rollback, Please correct the error manually and retry rollback 

Explanation    Undoing the rollback changes (for atomic behavior) Failed

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_SYSLOG_INIT_FAILED: Ascii config Syslog Init Error 

Explanation    Error encountered while Initializing Syslog for Ascii Config

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

ASCII-CFG-3

Error Message     ASCII-CFG-3-ACFG_MTSERROR: [chars] 

Explanation    Ascii-cfg-server (rollback process) encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

ASCII-CFG-6

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_CLEAR_DATABASE: cleared all the 
configuration checkpoints 

Explanation    Cleared all the configuration checkpoints

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_CREATED: Created configuration 
checkpoint [chars] 

Explanation    Created configuration checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_DELETED: Deleted configuration 
checkpoint [chars] 

Explanation    Deleted configuration checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_MAX_CHECKPOINTS: Maximum no of checpoints reached, 
Removing the oldest checkpoint 

Explanation    Maximum no.of checkpoints reached, removing the oldest checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_ATOMIC: Performing configuration rollback 
to checkpoint [chars] (with atomic option) 

Explanation    Performing configuration rollback with atomic option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_BEST: Performing configuration rollback to 
checkpoint [chars] (with best-effort option) 

Explanation    Performing configuration rollback with best-effort option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_FIRST_ERR: Performing configuration 
rollback to checkpoint [chars] (with stop-at-first failure option) 

Explanation    Performing configuration rollback with stop-at-first-failure option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-INFORMATION: [chars] 

Explanation    An event happend that affects Acfg-Rollback. [chars] indicates the event

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-PSS_ERR: [chars] 

Explanation    An error occurred during an Acfg PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BIOS DAEMON Messages

This section contains the BIOS DAEMON messages.

BIOS DAEMON-2

Error Message    BIOS_DAEMON-2-BIOS_DAEMON_FLASH_WARNING: Flash chip not supported by 
running image. Skipping bios upgrade. 

Explanation    BIOS CHIP NOT SUPPORTED

Recommended Action    No action is required.

Error Message     BIOS_DAEMON-2-BIOS_DAEMON_PRI_BOOT_FAIL: Primary BIOS is corrupted or 
un-bootable 

Explanation    PRIMARY BIOS CORRUPTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     BIOS_DAEMON-2-BIOS_DAEMON_SUP_ERROR: BIOS Sector ([dec]) is write 
protected 

Explanation    BIOS WRITE PROTECTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BIOS_DAEMON-SLOT#-2

Error Message     BIOS_DAEMON-SLOT#-2-BIOS_DAEMON_LC_ERROR: BIOS Sector ([dec]) is 
write protected 

Explanation    BIOS WRITE PROTECTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     BIOS_DAEMON-SLOT#-2-BIOS_DAEMON_LC_PRI_BOOT_FAIL: Primary BIOS is 
corrupted or un-bootable 

Explanation    PRIMARY BIOS CORRUPTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BOOTUP TEST Messages

This section contains the BOOTUP TEST messages.

BOOTUP TEST-2

Error Message    BOOTUP_TEST-2-EOBC_FAIL: Module [dec] has failed test [chars] on EOBC 
due to error [chars] 

Explanation    Online diagnostics EOBC test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-EOBC_SKIP: Module [dec] has failed test [chars] on EOBC 
due to error [chars] 

Explanation    Online diagnostics ManagementPort test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-MGMT_PORT_FAIL: Module [dec] has failed test [chars] on 
Management Port due to error [chars] 

Explanation    Online diagnostics ManagementPort test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-MGMT_PORT_SKIP: Module [dec] has skipped test [chars] 
on Management Port due to error [chars] 

Explanation    Online diagnostics ManagementPort test is skipped

Recommended Action    No action is required.

BOOTVAR Messages

This section contains the BOOTVAR messages.

BOOTVAR-2

Error Message    BOOTVAR-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate memory.

Recommended Action    Check if the system is low on memory, if so reset the switch.

Error Message     BOOTVAR-2-AUTOCOPY_FAILED: Autocopy of file [chars] to standby 
failed. [chars] (Error-id: [hex]) 

Explanation    The image deemed to be copied to standby via the auto-copy feature failed.

Recommended Action    Check error id for specified reason.

Error Message     BOOTVAR-2-AUTOSYNC_FAILED: Image autosync failed. Reason: [chars] 
([hex]) 

Explanation    Image synchronization failed.

Recommended Action    Check that there is enough space on the flash, as well as system high availability status.

Error Message     BOOTVAR-2-CONFIG_ERROR: Failed to update boot configuration 

Explanation    An error has occurred during the update of the boot configuration files

Recommended Action    Check that there is enough space on the flash, show boot to check the configured image names, show loader internal configuration to compare them with the current bootloader configuration, if they are not coherent do write erase and retry to save the configuration.

Error Message     BOOTVAR-2-IMAGE_NOT_COMPATIBLE: Warning: image [chars] is not 
compatible with the current platform in SUP [dec] 

Explanation    The input image name is not compatible with the current platform.

Recommended Action    Make sure a right image is specified before reboot.

BOOTVAR-3

Error Message     BOOTVAR-3-AUTOCOPY_FAILED_STANDBY_FULL: Autocopy of file [chars] to 
standby failed due to not enough disk space on standby

Explanation    There is not enough disk space on the standby for the file to be copied.

Recommended Action    Clear space on the standby disk.

Error Message     BOOTVAR-3-INIT_FAILED: Initialization failed: Component [chars] 

Explanation    The service failed to start The failure occurs during initialization of the component [chars].

Recommended Action    Show processes to check the status of the other processes, pay attention to the specified component.

Error Message     BOOTVAR-3-LOAD_VERIFY_LIB_FAILED: Fetching library [chars] failed, 
reason=[chars] 

Explanation    Failed to load bootvar specified verification library.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-MODULE_LOCK_FAIL: Unable to get module lock, please don't 
reload <error-id:[hex]> 

Explanation    Unable to acquire modlock to prevent user to reload during auto-sync.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-NEIGHBOR_REJECT_AUTOCOPY: auto-copy failed - not supported 
by neighbor supervisor. 

Explanation    Standby supervisor does not support auto-copy, thus failed.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-VERIFY_FAILED: Image [chars] for bootvar [chars] 
verification failed, reason=[chars] 

Explanation    The image set for this bootvar has failed the verification process, this is just a warning.

Recommended Action    Check reason to determine actions.

BOOTVAR-5

Error Message     BOOTVAR-5-AUTOCOPY_SUCCEED: auto-copy of file [chars] to standby 
supervisor succeed 

Explanation    Auto copy of the file succeed, image integrity verified by standby.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-AUTOCOPY_VERIFY_SEND_FAILED: Unable to ask standby to 
verify file [chars], error = [hex] 

Explanation    Upon copied the image to standby, failed to send message to ask standby to verify integrity.

Recommended Action    Turn auto-copy off and back on.

Error Message     BOOTVAR-5-AUTOSYNC_DONE: Image autosync done 

Explanation    The image synchronization done successfully.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-AUTOSYNC_REBOOT: Rebooting standby after successful 
autosync 

Explanation    Image autosync has been successful, resetting the standby supervisor to load the new image.

Recommended Action    Check that the standby sup reloads correctly.

Error Message     BOOTVAR-5-AUTOSYNC_START: Starting image autosync. Please wait until 
completion... 

Explanation    The standby-sup has requested the sync of the current image.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-IMAGE_NOTEXISTS: Warning: image [chars] doesn't exist on 
sup[dec] 

Explanation    The input image name doesn't exist on the specified supervisor.

Recommended Action    Check whether the input image name you entered exists and make sure that you have the image on the flash before reboot.

Error Message     BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor 
supervisor, starting... 

Explanation    Info log reporting standby's support of auto-copy. Auto-copy is being started.

Recommended Action    No action is required.

BOOTVAR-6

Error Message     BOOTVAR-6-ALREADY_IN_SYNC: Image already in sync 

Explanation    No need to update the image on the standby-sup.

Recommended Action    No action is required.

Error Message     BOOTVAR-6-AUTOCOPY_DID_NOT_START: Autocopy of file [chars] to standby 
did not start. [chars] (Error-id: [hex])

Explanation    Autocopy of the file did not start as the remote copy location does not exist

Recommended Action    No action is required.

Error Message     BOOTVAR-6-CONFIG_UPDATED: Boot configuration updated 

Explanation    The boot-loader configuration files have been successfully updated.

Recommended Action    No action is required.

Error Message     BOOTVAR-6-STARTING: Boot configuration initialized 

Explanation    The service has successfully started.

Recommended Action    No action is required.

CALLHOME Messages

This section contains the CALLHOME messages.

CALLHOME-2

Error Message    CALLHOME-2-EVENT: [chars] 

Explanation    Callhome event [chars] occurred.

Recommended Action    If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error

Error Message     CALLHOME-2-PROGRAM_EXIT: callhome process ending: [chars] 

Explanation    Callhome process is exiting with reason [chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CALLHOME-3

Error Message     CALLHOME-3-CALLHOME_CFS_MERGE_OPERATION_FAILED: [chars] 

Explanation    [chars1]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CALLHOME-3-CALLHOME_CFS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CALLHOME-3-CALLHOME_MAX_ALERT_MSG: [chars] 

Explanation    [chars]

Recommended Action    Please check the reason for the generation of the callhome messages and rectify the problem

Error Message     CALLHOME-3-EVENT_PROCESS_ERROR: error in processing callhome event 
[chars] reason:[chars] 

Explanation    Error in processing callhome event [chars] reason:[chars]

Recommended Action    Please check your callhome configuration for proper configuration. Please check SMTP server address, email addresses for destination profiles and enable status of callhome. Use show callhome commands for displaying configuration.

Error Message     CALLHOME-3-MESSAGE_SIZE_EXCEED: message size for callhome 
alert:[chars] exceeds maximum limit for destination profile:[chars]

Explanation    Message size for callhome alert:[chars] exceeds maximum limit for destination profile:[chars]

Recommended Action    Please check the maximum message size for the destination profile under question. Increase it if possible to match the maximum limit allowed by your email destinations.

CALLHOME-6

Error Message     CALLHOME-6-NONCRIT_EVENT: [chars] 

Explanation    Non-critical Callhome event [chars] occurred.

Recommended Action    If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error.

CDP Messages

This section contains the CDP messages.

CDP-2

Error Message    CDP-2-INITFAIL: CDP Daemon Initialization failed: [chars] 

Explanation    CDP Daemon Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

CDP-3

Error Message     CDP-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    CDP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     CDP-3-GENERROR: [chars] 

Explanation    CDP Daemon encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     CDP-3-MCASTBINDFAIL: Failed to bind for CDP multicast address on 
interface [hex] - [chars]

Explanation    An attempt to register for packets destined to the CDP multicast address failed. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-MTSERROR: [chars] 

Explanation    CDP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     CDP-3-PKTRECVFAIL: Failed to receive packet - [chars] 

Explanation    Failed to receive packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-PKTSENDFAIL: Failed to send packet, interface [hex] - [chars] 

Explanation    Failed to send packet. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-PSSERROR: [chars] 

Explanation    CDP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     CDP-3-SOCKBINDFAIL: Failed to bind to raw socket, interface [hex] - 
[chars] 

Explanation    Failed to bind to raw socket. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-SOCKOPENFAIL: Failed to open socket for receiving raw 802_2 
packets - [chars] 

Explanation    An attempt to open a socket for receiving raw 802_2 packets failed. [char] identifies the reason.

Recommended Action    No action is required.

CDP-4

Error Message     CDP-4-DUPLEX_MISMATCH: Duplex mismatch discovered on [chars], with 
[chars] 

Explanation    Duplex mismatch discovered from the received cdp packet This is a warning message.

Recommended Action    No action is required.

Error Message     CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on 
[chars]([dec]), with [chars]([dec]) 

Explanation    Native VLAN mismatch discovered This is a warning message.

Recommended Action    No action is required.

CDP-5

Error Message     CDP-5-DISABLED: CDP is disabled 

Explanation    CDP is disabled on the device.

Recommended Action    No action is required.

Error Message     CDP-5-ENABLED: CDP is enabled 

Explanation    CDP is enabled on the device.

Recommended Action    No action is required.

CDP-6

Error Message     CDP-6-CDPDUP: CDP Daemon Up. 

Explanation    CDP Daemon was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-CDPEXIT: CDP Daemon shutting down gracefully. 

Explanation    CDP Daemon is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-NEIGHBOR_ADDED: Device [chars] discovered of type [chars] with 
port [chars] on incoming port [chars] with ip addr [chars] and mgmt ip [chars]

Explanation    Discovered a neighbor device. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-NEIGHBOR_REMOVED: CDP Neighbor [chars] on port [chars] has been 
removed 

Explanation    Deleted a neighbor device. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTDISABLE: CDP disabled on port [chars] 

Explanation    CDP was disabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTDOWN: A CDP enabled port [chars] went down. 

Explanation    A CDP enabled port became un-operational. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTENABLE: CDP enabled on port [chars] 

Explanation    CDP was enabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTUP: A CDP enabled port [chars] came up. 

Explanation    A CDP enabled port became operational. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

CERT_ENROLL Messages

This section contains the CERT_ENROLL messages.

CERT_ENROLL-2

Error Message    CERT_ENROLL-2-CERT_EN_PROGRAM_EXIT: cert_enroll daemon exiting: 
[chars] 

Explanation    Cert_enroll daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CERT_ENROLL-3

Error Message     CERT_ENROLL-3-CERT_EN_ERROR_MESSAGE: [chars] 

Explanation    CERT_ENROLL Error Message

Recommended Action    No action is required.

Error Message     CERT_ENROLL-3-CERT_EN_FIPS_MODE_INIT_ERROR: Could not initialize FIPS 
mode : [chars] 

Explanation    FIPS mode initialization error

Recommended Action    No action is required.

CERT_ENROLL-6

Error Message     CERT_ENROLL-6-CERT_EN_MESSAGE: [chars] 

Explanation    CERT_ENROLL Message

Recommended Action    No action is required.

CFS Messages

This section contains the CFS messages.

CFS-2

Error Message    CFS-2-CFS_REJECT: CFS reject: [chars]: Switch WWN [chars], ip [chars], 
reason [chars] 

Explanation    CFS reject: [chars] Switch WWN [chars], ip [chars], reason [chars]

Recommended Action    No action is required.

Error Message     CFS-2-EXITING: Exit reason: [chars] 

Explanation    The CFS service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     CFS-2-GENERAL_ERROR: [chars] 

Explanation    The CFS service has encountered an critical error. The description of error is [str.]

Recommended Action    No action is required.

Error Message     CFS-2-INITFAIL: CFS Service Init failed: [chars] 

Explanation    CFS Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     CFS-2-LOCK_FAILED: lock failed for sap [dec] due to internal error. 

Explanation    Lock failed due to Unrestricted uncoordinated count is out of sync for sap [dec]

Recommended Action    To recover from this state run command 'cfs internal decrement-unrestricted <app-sap>'

Error Message     CFS-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The CFS service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     CFS-2-MTS_REJECT: Verification failed reject MTS message SAP 
[dec]:RR-token [hex] 

Explanation    This MTS message could have been posted by the previous active running pre 3.x; MTS structure has changed since then hence ignore the MTS message, Source SAP [dec]; RR-token [hex]

Recommended Action    No action is required.

Error Message     CFS-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The CFS service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     CFS-2-VDC_MGR_FAIL: Failed to get a valid switch mac from VDC Manager: 
[chars] 

Explanation    VDC manager did not respond with a proper MAC address. It could have been because of a timeout in MTS received

Recommended Action    No action is required.

CFS-3

Error Message     CFS-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    CFS Service is out of dynamic memory. [chars] specifies the context where the failure occured

Recommended Action    No action is required.

Error Message     CFS-3-APP_MERGE_FAILED: Merge failed for app [chars], local switch 
wwn [chars], remote switch wwn [chars].Please check 'show cfs merge status name 
[chars]' for more information

Explanation    The CFS service has detected a merge failure.

Recommended Action    No action is required.

Error Message     CFS-3-CFS_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The CFS service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     CFS-3-DBERROR: [chars] 

Explanation    CFS Service encountered a database error. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-FAILURE_RESPONSE: [chars] [hex] 

Explanation    CFS Service failed to get response [chars][hex] specify the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-FIPS_TEST_FAILED: FIPS compliance test failed 

Explanation    FIPS compliance test failed

Recommended Action    No action is required.

Error Message     CFS-3-GENERROR: [chars] 

Explanation    CFS Service encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     CFS-3-LICERR: [chars] 

Explanation    CFS Service failed to get license.

Recommended Action    No action is required.

Error Message     CFS-3-MERGE_FAILED: Merge failed for app [chars], local switch wwn 
[chars],ip [chars], remote switch wwn [chars], ip [chars]

Explanation    The CFS service has detected a merge failure.

Recommended Action    No action is required.

Error Message     CFS-3-MTSERROR: [chars] 

Explanation    CFS Service encountered an MTS error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

Error Message     CFS-3-PSSERROR: [chars] 

Explanation    CFS Service encountered a PSS error. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-TIMEOUT_ERROR: [chars] [hex] 

Explanation    CFS Service encountered a timeout [chars][hex] specify the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-UNKNOWN_MSG: Recvd. from Node=[dec] SAP=[dec] 

Explanation    The CFS service has received an unknown message from [dec]].[dec]. This information is for debugging only.

Recommended Action    No action is required.

CFS-4

Error Message     CFS-4-LICEXP: [chars] 

Explanation    CFS Service license is going to expire. [chars] gives the expected time of expiry

Recommended Action    No action is required.

Error Message     CFS-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the CFS service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

CFS-6

Error Message     CFS-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The CFS service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     CFS-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The CFS service became standby from active mode.

Recommended Action    No action is required.

Error Message     CFS-6-EXCESSIVE_DELAY: [chars] 

Explanation    Excessive time taken for a processing event. The description of the event is [str.]

Recommended Action    No action is required.

Error Message     CFS-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The CFS service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     CFS-6-GENERAL_EVENT: [chars] 

Explanation    The CFS service has generated an important event. The description of the event is [str.]

Recommended Action    No action is required.

Error Message     CFS-6-INVALID_CHECKSUM: Received packet from peer on if-index([hex]) 
with corrupted checksum 

Explanation    This could be because of errors in the link

Recommended Action    No action is required.

Error Message     CFS-6-INVALID_IF_INDEX: Received packet on if-index([hex]) which is 
not recognized by CFS 

Explanation    The if-index does not match with the if-index used in discovery or we might have already recieved an adjacency cleanup message for this if-index. Check if the if-index is that of the port-channel or a physical if-index

Recommended Action    No action is required.

Error Message     CFS-6-LOGICAL_DISTRIBUTION_INFO: vsan [dec], source wwn [chars], ip 
[chars] app-id [dec], session-id [dec], user [chars], [chars] 

Explanation    Vsan [dec], source wwn [chars], ip [chars], app-id [dec], user [chars], event [chars]

Recommended Action    No action is required.

Error Message     CFS-6-PHY_DISTRIBUTION_INFO: source wwn [chars], ip [chars], app-id 
[dec], session-id [dec], user [chars], [chars] 

Explanation    Source wwn [chars], ip [chars], app-id [dec], session-id [dec], user [chars], event [chars]

Recommended Action    No action is required.

Error Message     CFS-6-PSS_CREATED: [chars] PSS Created 

Explanation    One of the persistent information database of CFS service has been recreated

Recommended Action    No action is required.

Error Message     CFS-6-PSS_DESTROYED: [chars] PSS Destroyed 

Explanation    One of the persistent information databases of CFS Service has been intentionally destroyed and would be recreated.

Recommended Action    No action is required.

Error Message     CFS-6-REGION_CTX_REMOVED: Region info is deleted for [chars] 

Explanation    [chars] is in logical scope. Regions are supported only physical scope applications

Recommended Action    No action is required.

Error Message     CFS-6-SERVICE_UP: Initialized [chars] 

Explanation    The CFS service is up and ready to accept client requests The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     CFS-6-SRVCREATED: CFS Service created 

Explanation    CFS Service was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     CFS-6-SRVEXIT: CFS Service shutting down gracefully 

Explanation    CFS Service is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     CFS-6-SWITCHOVER: Switching Over to other Sup. 

Explanation    The CFS service has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

CIMSRVPROV Messages

This section contains the CIMSRVPROV messages.

CIMSRVPROV-2

Error Message    CIMSRVPROV-2-CIM_SYSLOG_EXIT: Message:[chars] errcode:[dec] 

Explanation    Exit due to critical error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-2-CIM_SYSLOG_PSS_SNAPSHOT_ERR: Source URI:[chars] 
Destination URI:[chars] errcode:[dec] 

Explanation    PSS snapshot error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-2-CIM_SYSLOG_SDWRAP_ERR: Description:[chars] 
errcode:[dec] 

Explanation    Debug infrastructure error

Recommended Action    No action is required.

CIMSRVPROV-3

Error Message     CIMSRVPROV-3-CIM_SYSLOG_COPY_CONFIG_ERR: Message:[chars] URI:[chars] 
errcode:[dec] 

Explanation    Copy running startup error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_FILE_ERR: Purpose:[chars] Filename:[chars] 
errcode:[dec] 

Explanation    File handling error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_MTS_ERR: message [chars] 

Explanation    MTS message handling error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_PSS_ERR: Purpose:[chars] URI:[chars] 
errcode:[dec] 

Explanation    PSS handling error

Recommended Action    No action is required.

CIMSRVPROV-6

Error Message     CIMSRVPROV-6-LOG_CIM_CERTIFICATE_CLEARED: Cleared certificate 
[chars] 

Explanation    Cleared a certificate named [chars].

Recommended Action    No action is required.

Error Message     CIMSRVPROV-6-LOG_CIM_CERTIFICATE_INSTALLED: Installed certificate 
[chars] 

Explanation    Installed a certificate named [chars].

Recommended Action    No action is required.

CLIS Messages

This section contains the CLIS messages.

CLIS-5

Error Message    CLIS-5-CLIS_SYSLOG_CMD_REMOVED: Command deleted from the NVDB: [chars] 

Explanation    Command removal due to configuration change

Recommended Action    No action is required.

CLOUD Messages

This section contains the CLOUD messages.

CLOUD-2

Error Message    CLOUD-2-PROGRAM_EXIT: cloud-discovery process ending: [chars] 

Explanation    Cloud-discovery process is exiting with reason [chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CLOUD-3

Error Message     CLOUD-3-CLOUD_CFS_MERGE_OPERATION_FAILED: [chars] 

Explanation    [chars1]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CLOUD-3-CLOUD_CFS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CLOUD-3-CLOUD_FEATURE_MANAGER_ERROR: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for error using feature manager and rectify the problem

Error Message     CLOUD-3-CLOUD_PSS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the pss operation and rectify the problem

CLOUD-6

Error Message     CLOUD-6-CLOUD_DISCOVERY_DONE: discovery over 

Explanation    Cloud-discovery started

Recommended Action    Check cloud membership

Error Message     CLOUD-6-CLOUD_DISCOVERY_STARTED: [chars] discovery started 

Explanation    Cloud-discovery started

Recommended Action    Check cloud-discovery status after sometime

CLUSTER Messages

This section contains the CLUSTER messages.

CLUSTER-2

Error Message    CLUSTER-2-CLUSTER_CAP_ADD_FAIL: Failed to add cluster capability [dec] 

Explanation    Cluster capability addition failed

Recommended Action    No action is required.

Error Message     CLUSTER-2-CLUSTER_CAP_DEL_FAIL: Failed to delete cluster capability 
[dec] 

Explanation    Cluster capability deletion failed

Recommended Action    No action is required.

CMPPROXY Messages

This section contains the CMPPROXY messages.

CMPPROXY-2

Error Message    CMPPROXY-2-LOG_CMP_IS_NOT_UP: Connectivity Management processor (on 
module [dec]) did not come up 

Explanation    Connectivity Management processor is not sending heartbeats on this module

Recommended Action    No action is required.

Error Message     CMPPROXY-2-LOG_CMP_UP: Connectivity Management processor(on module 
[dec]) is now UP 

Explanation    Connectivity Management processor has come up and is exchanging heartbeats with CP on this SUP slot

Recommended Action    No action is required.

Error Message     CMPPROXY-2-LOG_CMP_WENT_DOWN: Connectivity Management processor (on 
module [dec]) went DOWN 

Explanation    Connectivity Management processor has either gone down or is not sending heartbeats for a long time

Recommended Action    No action is required.

CMPPROXY-5

Error Message     CMPPROXY-5-LOG_CMP_AAA_FAILURE: Authentication failed for a login 
from CMP (on module [dec]) 

Explanation    A login attempt has been denied access from Connectivity management processor (CMP) as authentication did not succeed

Recommended Action    No action is required.

Error Message     CMPPROXY-5-MALLOC_FAILURE: Memory allocation failure 

Explanation    Memory allocation in a call to malloc/calloc has failed.

Recommended Action    No action is required.

CMPPROXY-6

Error Message     CMPPROXY-6-LOG_CMP_AAA_SUCCESS: Authentication succeeded for a login 
from CMP (on module [dec]) 

Explanation    A login attempt has succeeded from Connectivity management processor (CMP) in getting access as AAA succeeded

Recommended Action    No action is required.

COPP Messages

This section contains the COPP messages.

COPP-2

Error Message    COPP-2-COPP_INIT_FAIL: CoPP Initialization failed: [chars] 

Explanation    CoPP Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-2-COPP_MTS_FAIL: Failed to do MTS operation: [chars] 

Explanation    Failed to do MTS operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

COPP-3

Error Message     COPP-3-COPP_ALLOC_FAIL: Memory allocation failure: [chars] 

Explanation    Failed to alloc required memory. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-3-COPP_PPF_FAIL: Error during PPF operation: [chars] 

Explanation    Failed to do PPF operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-3-COPP_PSS_FAIL: Error during PSS operation: [chars] 

Explanation    Failed to do PSS operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

COPP-5

Error Message     COPP-5-COPP_DISABLED: COPP Disabled 

Explanation    COPP Service Disabled

Recommended Action    No action is required.

Error Message     COPP-5-COPP_ENABLED: COPP Enabled 

Explanation    COPP Service nabled

Recommended Action    No action is required.

Error Message     COPP-5-COPP_INIT: COPP initialized 

Explanation    COPP Service Initialized

Recommended Action    No action is required.

COPP-6

Error Message     COPP-6-COPP_POLICY_ATTACHED: CoPP policy has been attached to control 
plane interface. 

Explanation    CoPP policy has been attached to control plane interface.

Recommended Action    No action is required.

Error Message     COPP-6-COPP_POLICY_DETACHED: CoPP policy has been detached from 
control plane interface. 

Explanation    CoPP policy has been detached from control plane interface.

Recommended Action    No action is required.

CORE-DMON Messages

This section contains the CORE-DMON messages.

CORE-DMON-2

Error Message     CORE-DMON-2-MODULE_COREDUMP_DONE: kernel coredump completed on 
module:[dec] 

Explanation    Kernel coredump finishing on a module

Recommended Action    No action is required.

Error Message     CORE-DMON-2-MODULE_COREDUMP_STARTED: kernel coredump started on 
module:[dec] 

Explanation    Kernel coredump starting on a module

Recommended Action    No action is required.

CORE-DMON-3

Error Message     CORE-DMON-3-NO_SPACE: Failed to save core file [chars]. Try removing 
existing core files. 

Explanation    Not enough space to save new core files

Recommended Action    No action is required.

CPPA_MGR Messages

This section contains the CPPA_MGR messages.

CPPA_MGR-3

Error Message    CPPA_MGR-3-ENABLE_VB_FAILURE: Virtual service blade [dec] could not be 
[chars]. Error: [chars] 

Explanation    The requested virtual blade operation could not be completed

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-NO_HB_REBOOT: No heartbeat from agent service. Nexus1010 
is rebooted 

Explanation    No heartbeat from agent service. Nexus1010 is rebooted

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-REMOTE_ILO_REBOOT: Remote mgmt feature rebooted other 
Nexus1010 using ILO 

Explanation    Remote mgmt feature rebooted other Nexus1010 using ILO

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-RESTORE_FAILURE: Agent version could not be restored to 
make versions match 

Explanation    The previous agent version could not be restored. System needs to be reinstalled to recover

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-SOME_PNIC_FAILURE: Not all the Nexus1010 physical NICs are 
detected. Check for failure 

Explanation    Not all the physical NICs are detected. Check for failure

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-UNDO_WRITE_ERASE: Undo Write Erase: [chars] 

Explanation    The software undo write erase result:

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-UPGRADE_FAILED: Upgrade failed: [chars] 

Explanation    The software upgrade could not complete because of errors

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-VERSION_MISMATCH: Agent version mismatch detected. System 
will be reloaded 

Explanation    The cppa_mgr and the underlying agent are not running the same software version

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-WRITE_ERASE: Write Erase: [chars] 

Explanation    The software write erase result:

Recommended Action    No action is required.

CPPA_MGR-5

Error Message     CPPA_MGR-5-REMOTE_VB_HA_FAILURE: Operation failed in standby for 
virtual service blade [dec]: [chars] 

Explanation    An error occurred while processing a command from active at standby

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-REMOTE_VB_IMG_FAILURE: Could not verify image in standby 
for virtual service blade [dec] creation: [chars] 

Explanation    An error occurred while processing image required for vb creation at standby

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-UPGRADE_COMPLETE: Upgrade completed successfully 

Explanation    The software upgrade completed with no errors

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-UPGRADE_START: Upgrade started. Image: [chars] 

Explanation    A software upgrade has been initiated by the user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_DEPLOYED: Virtual service blade [chars] deployed 

Explanation    Virtual service blade deployed on nexus1010 successfully

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_REMOVED: Virtual service blade [chars] removed 

Explanation    Virtual service blade removed by user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_RESTARTED: Virtual service blade [chars] restarted 

Explanation    Virtual service blade restarted by user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_SHUT: Virtual service blade [chars] moved into shut 
state 

Explanation    Virtual service blade shut by user

Recommended Action    No action is required.

CREDITMON Messages

This section contains the CREDITMON messages.

CREDITMON-SLOT#-2

Error Message    CREDITMON-SLOT#-2-SYSERR_CREDITMON_APP_EXITED: [chars] 

Explanation    Credit Monitor application exited

Recommended Action    No action is required.

Error Message     CREDITMON-SLOT#-2-SYSERR_CREDITMON_MTS_INIT_ERR: [chars] 

Explanation    Credit Monitor error binding to MTS

Recommended Action    No action is required.

CTS Messages

This section contains the CTS messages.

CTS-2

Error Message     CTS-2-CTS_AUTHENT_FAILURE: CTS Authentication failure on Port [chars] 
(CTS Failure Reason: [chars] [chars]) 

Explanation    Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port

Recommended Action    No action is required.

Error Message     CTS-2-DBG_INIT_FAILED: Debug Infrastructure Initialization failed ( 
[chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an E_Port 
failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the FC-2 E-Port infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an F_Port 
failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the FC-2 F-Port infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown FC-2 
frame on [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-FSMU_INIT_FAILED: State Machine Infrastructure Initialization 
failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-IPC_INIT_FAILED: IPC (Inter Process Communication) 
Initialization failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the IPC infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service 
exiting 

Explanation    License of [chars] is unavailable. Service will exit now

Recommended Action    Please install the license file to continue using the feature.

Error Message     CTS-2-MEM_FAILED: Memory operations failed File: [chars] Line [dec] 
for size [hex] bytes 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-POST_INIT_FAILED: Post-Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed ( 
[chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_ENFORCEMENT_FAILED: RBACL enforcement failed on [chars] 
[dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_LC_INSERT_FAILED: RBACL programming failed for inserted 
module [dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_TCAM_SPACE_NOT_ENOUGH: Not enough free space left on TCAM 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_UNABLE_PARSE_ACE: Unable to parse RBACL ACE substring: 
[chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_UPDATE_FAILED: Failed to [chars] RBACL [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

CTS-3

Error Message     CTS-3-DOT1X_AUTHC_FAILED: DOT1X authentication failed on port: 
[chars] 

Explanation    DOT1X authentication failed on the port

Recommended Action    No action is required.

CTS-5

Error Message     CTS-5-CTS_IP_SGT_MAP_UPDATE: [chars] assigned SGT [dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

DEBUGPROXY Messages

This section contains the DEBUGPROXY messages.

DEBUGPROXY-6

Error Message    DEBUGPROXY-6-SSM_DEBUG_PROXY_COMMON: SSM debug proxy [chars] [dec] 

Explanation    General SSM debug proxy information

Recommended Action    No action is required.

DEVICE-ALIAS Messages

This section contains the DEVICE-ALIAS messages.

DEVICE-ALIAS-2

Error Message    DEVICE-ALIAS-2-ALLOC_FAILED: Memory allocation failed for size:[dec] 
type:[dec] 

Explanation    Memory allocation failed for size [dec] type [dec]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-2-INIT_FAILED: [chars] 

Explanation    An error occurred during initialization. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DEVICE-ALIAS-3

Error Message     DEVICE-ALIAS-3-CFS_OPER_FAILED: [chars] 

Explanation    An error occurred while performing a CFS operation. [chars] indicates the CFS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the session. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-COMMIT_FAILED: [chars] 

Explanation    An error occurred while committing the database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-COMMIT_REJECTED: [chars] 

Explanation    Commit request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-LOCK_REJECTED: [chars] 

Explanation    Lock request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    An error occurred while activating the merged database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_ACTIVATION_REJECTED: [chars] 

Explanation    Merge activation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_FAILED: [chars] 

Explanation    An error occurred during merge operation. [chars] indicates the reason for failure.

Recommended Action    Compare device-alias configuration with the other switches in the fabric, resolve the conflicts if any and commit the changes.

Error Message     DEVICE-ALIAS-3-MERGE_MREQ_REJECTED: [chars] 

Explanation    MREQ received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_MRESP_REJECTED: [chars] 

Explanation    MRESP received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_VALIDATION_FAILED: [chars] 

Explanation    An error occurred while validating the merged database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_VALIDATION_REJECTED: [chars] 

Explanation    Merge validation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MTS_OPER_FAILED: [chars] 

Explanation    An error occurred during MTS operation. [chars] indicates the MTS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-PSS_OPER_FAILED: [chars] 

Explanation    An error occurred during PSS operation. [chars] indicates the PSS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the lock. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-UNLOCK_REJECTED: [chars] 

Explanation    Unlock request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-VALIDATION_FAILED: [chars] 

Explanation    An error occurred while validating the database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-VALIDATION_REJECTED: [chars] 

Explanation    Validation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DEVICE-ALIAS-6

Error Message     DEVICE-ALIAS-6-CLEAR_FAILED_INFO: [chars] 

Explanation    An error occurred while clearing the session. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-COMMIT_FAILED_INFO: [chars] 

Explanation    An error occurred while committing the database. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-IMPORT_DEFINITION_CONFLICT: Fcalias [chars] could not 
be imported due to definition conflict

Explanation    Fcalias [chars] could not be imported due to definition conflict. Either there is already a device-alias configuration present with the same definition OR another VSAN specified in the import VSAN range has an fcalias with the same definition.

Recommended Action    Resolve the conflict and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_MEMBER_TYPE_CONFLICT: Fcalias [chars] could not 
be imported due to having unsupported member type

Explanation    Fcalias [chars] could not be imported due to having unsupported member types. Fcalias can be imported only if it has Port WWN based members..

Recommended Action    Make sure that the fcalias has Port WWN based members and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_NAME_CONFLICT: Fcalias [chars] could not be 
imported due to name conflict 

Explanation    Fcalias [chars] could not be imported due to name conflict. Either there is already a device-alias configuration present with the same name OR another VSAN specified in the import VSAN range has an fcalias with the same name.

Recommended Action    Resolve the conflict and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_NUM_MEMBERS_CONFLICT: Fcalias [chars] could not 
be imported due to having unsupported number of members

Explanation    Fcalias [chars] could not be imported due to having unsupported number of members. Fcalias can be imported only if it has exactly one member..

Recommended Action    Make sure that the fcalias has exactly one member and issue the import command again.

Error Message     DEVICE-ALIAS-6-LOCK_FAILED_INFO: [chars] 

Explanation    An error occurred while acquiring the lock. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-MERGE_ACTIVATION_FAILED_INFO: [chars] 

Explanation    An error occurred while activating the merged database. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-MERGE_VALIDATION_FAILED_BUSY: [chars] 

Explanation    Merged database could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.

Recommended Action    No DDTS.

Error Message     DEVICE-ALIAS-6-MERGE_VALIDATION_REJECTED_BUSY: [chars] 

Explanation    Merged database received from the remote switch could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.

Recommended Action    No DDTS.

Error Message     DEVICE-ALIAS-6-UNLOCK_FAILED_INFO: [chars] 

Explanation    An error occurred while releasing the lock. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-VALIDATION_ABORTED: [chars] 

Explanation    Local validation is aborted. [chars] indicates the reason why validation is aborted.

Recommended Action    No DDTS.

DEVICE_TEST Messages

This section contains the DEVICE_TEST messages.

DEVICE_TEST-2

Error Message    DEVICE_TEST-2-ASIC_REG_CHECK_FAIL: Module [dec] has failed test 
[chars] [dec] times on device [chars] [chars] [dec] frontpanel ports affected 
[chars] due to error [chars] 

Explanation    Online diagnostics ASICRegisterCheck test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-COMPACT_FLASH_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Compact Flash due to error [chars] 

Explanation    Online diagnostics CompactFlash test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-CRYPTO_DEVICE_FAIL: Module [dec] has failed test 
[chars] [dec] times on Crypto device due to error [chars] 

Explanation    Online diagnostics CryptoDevice test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-FAN_MOD_FAIL: Module [dec] has failed test [chars] 
[dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error 
[chars] error number [hex] 

Explanation    Online diagnostics SystemMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-MALLOC_FAILURE: Memory allocation failed 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-NVRAM_FAIL: Module [dec] has failed test [chars] [dec] 
times on device NVRAM due to error [chars] 

Explanation    Online diagnostics NVRAM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-POWER_SUPPLY_FAIL: Module [dec] has failed test [chars] 
[dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error 
[chars] error number [hex] 

Explanation    Online diagnostics SystemMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-PRIMARY_BOOTROM_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Primary BootROM due to error [chars] 

Explanation    Online diagnostics PrimaryBootROM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-PWR_MGMT_BUS_FAIL: Module [dec] has failed test [chars] 
[dec] times on device Power Mgmt Bus on slot [dec] due to error [chars] error 
number [hex] 

Explanation    Online diagnostics PwrMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-RTC_FAIL: Module [dec] has failed test [chars] [dec] 
times on device RealTimeClock due to error [chars] 

Explanation    Online diagnostics RealTimeClock test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-SECONDARY_BOOTROM_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Secondary BootROM due to error [chars] 

Explanation    Online diagnostics SecondaryBootROM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-SPINE_CONTROL_BUS_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Spine Control Bus on slot [dec] due to error [chars] 
error number [hex] 

Explanation    Online diagnostics SpineControlBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-STANDBY_LOOPBACK_TEST_FAIL: Module [dec] has failed 
test [chars] [dec] times on [chars] [dec] due to error [chars] 

Explanation    Online diagnostics StandbyFabricLoopback test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-TWOWIRE_STW_FAIL: Module [dec] has failed test [chars] 
[dec] times on Status Bus on slot [dec] due to error [chars] 

Explanation    Online diagnostics Status bus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-USB_FAIL: Module [dec] has failed test [chars] [dec] 
times on device USB due to error [chars] 

Explanation    Online diagnostics USB test has failed

Recommended Action    No action is required.

DEVICE_TEST-3

Error Message     DEVICE_TEST-3-STANDBY_TEST_GET_DIAG_VQI_FAIL: Standby test get diag 
vqi failed due to error [hex] 

Explanation    Device Test StandbyLoopback Test failed get vqi

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_GET_SPINE_FAIL: Standby test get spines 
failed due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test get spine failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_INIT_FAIL: Init for standby test failed 
due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test failed init process

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_MTS_FAIL: Mts Init for standby test failed 
due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test failed mts init

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_SOCKET_FAIL: Standby test socket error 
[chars]: [hex] 

Explanation    Device Test StandbyFabricLoopback Test Socket error

Recommended Action    No action is required.

DEVICE_TEST-4

Error Message     DEVICE_TEST-4-THREAD_CREATE_FAIL: Thread creation failed 

Explanation    Device Test process could not create threads

Recommended Action    No action is required.

Error Message     DEVICE_TEST-4-TIMER_CREATE_FAIL: Timer creation failed 

Explanation    Device Test process could not create timer

Recommended Action    No action is required.

Error Message     DEVICE_TEST-4-TIMER_START_FAIL: Timer start failed 

Explanation    Device Test process could not start timer

Recommended Action    No action is required.

DEVICE_TEST-5

Error Message     DEVICE_TEST-5-NOTICE_TEST: Memory allocation failed notice 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

DEVICE_TEST-6

Error Message     DEVICE_TEST-6-INFO_TEST: Memory allocation failed info 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

DEV_LOG Messages

This section contains the DEV_LOG messages.

DEV_LOG-3

Error Message    DEV_LOG-3-ERROR: [chars] 

Explanation    Dev_log_lc encountered an error

Recommended Action    No action is required.

DEV_LOG-SLOT#-4

Error Message     DEV_LOG-SLOT#-4-DEV_LOG_LC_ERROR: [chars] 

Explanation    Dev_log_lc encountered an error

Recommended Action    No action is required.

DFTM Messages

This section contains the DFTM messages.

DFTM-3

Error Message    DFTM-3-DFTM_BDDB_PROG_FAILED: DFTM failed to program BDDB Entry: 
[chars] 

Explanation    DFTM failed to program BDDB Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_BDT_PROG_FAILED: DFTM failed to program BD Table Entry: 
[chars] 

Explanation    DFTM failed to program BD Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_L2L3CT_PROG_FAILED: DFTM failed to program L2L3 
Consistency Table Entry: [chars] 

Explanation    DFTM failed to program L2L3 Consistency Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_MFT_PROG_FAILED: DFTM failed to program Multicast FTag 
Table Entry: [chars] 

Explanation    DFTM failed to program Multicast Ftag Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_SDT_PROG_FAILED: DFTM failed to program SGT DGT Table 
Entry: [chars] 

Explanation    DFTM failed to program SGT DGT Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_VTT_PROG_FAILED: DFTM failed to program VLAN Translation 
Table Entry: [chars] 

Explanation    DFTM failed to program VLAN Translation Table

Recommended Action    No action is required.

DHCP_SNOOP Messages

This section contains the DHCP_SNOOP messages.

DHCP_SNOOP-2

Error Message    DHCP_SNOOP-2-DHCP_SNOOP_PROGRAM_EXIT: [chars] 

Explanation    DHCP snoop process did an abnormal exit

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-INITFAIL: DHCP Daemon Initialization failed: [chars] 

Explanation    DHCP Daemon Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-PSSERROR: [chars] 

Explanation    DHCP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-REGPARTREE: Unable to register par tree: [chars] 

Explanation    Could not register par tree. [chars] explains the reason for the failure.

Recommended Action    No action is required.

DHCP_SNOOP-3

Error Message     DHCP_SNOOP-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    DHCP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-DHCPDENIEDARP: ARP frame denied due to DHCP snooping 
binding on interface [chars] vlan [dec] sender mac [chars] sender ip [chars] target 
mac [chars] target ip [chars].

Explanation    [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been denied. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-DHCPRATELIMIT: Interface [chars] has been error disabled 
due to excessive ingress rate [dec] of DHCP packets.

Explanation    [chars] identifies the interface which has been error disabled due to excessive ingress rate [dec].

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-HWPGMFAILURE: Hardware programming has failed: [chars] 

Explanation    Hardware programming has failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-INVDHCPPKTS: Validation errors while processing DHCP 
packet received on interface [chars] vlan [dec] Reason:[chars]. Dropping the 
packet

Explanation    Validation errors DHCP packet receieved on the interface [chars] vlan [[dec]]. Reason:[chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-MTSERROR: [chars] 

Explanation    DHCP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-PKTRECVFAIL: Failed to receive packet - [chars] 

Explanation    Failed to receive packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-PKTSENDFAIL: Failed to send packet, - [chars] 

Explanation    Failed to send packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-SOCKBINDFAIL: Failed to bind to raw socket - [chars] 

Explanation    Failed to bind to socket. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-SOCKOPENFAIL: Failed to open socket for receiving DHCP 
packets - [chars] 

Explanation    An attempt to open a socket for receiving DHCP packets failed. [char] identifies the reason.

Recommended Action    No action is required.

DHCP_SNOOP-4

Error Message     DHCP_SNOOP-4-ACL_DENY: [dec] Invalid ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-ACL_PERMIT: [dec] ARP messages ([chars]) on [chars], 
vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]]) 

Explanation    Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-DHCP_SNOOPING_DENY: [dec] Invalid ARP messages ([chars]) 
on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-DHCP_SNOOPING_PERMIT: [dec] ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]]) 

Explanation    Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-ERROR_DISABLED: Interface [chars] has moved to error 
disabled state due to excessive rate [dec] of ingress ARP packets

Explanation    Interface [chars] has moved to error disabled state due to excessive rate [dec] of ingress ARP packets

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-INVALID_ARP: [dec] Invalid ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

DHCP_SNOOP-6

Error Message     DHCP_SNOOP-6-DAIVLANDISABLE: DAI disabled on vlan [dec] 

Explanation    Dynamic ARP Inspection was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DAIVLANENABLE: DAI enabled on vlan [dec] 

Explanation    Dynamic ARP Inspection was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPEXIT: DHCP Daemon shutting down gracefully. 

Explanation    DHCP Daemon is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPHOSTADD: A new Host is [chars] connected to interface 
[chars] in VLAN [dec] and is allocated IP address [chars] for [dec] secs.

Explanation    A Host identified by [chars] has been added. [chars] identifies the interface. [dec] identifies the VLAN. [chars] identifies IP address. [dec] identifies the lease time in secs. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPLEASEEXPIRE: Lease expired for host [chars] having 
IP address [chars] connected to interface [chars] in VLAN [dec] for lease [dec] 
secs.

Explanation    The lease for host identified by [chars] with IP address [chars] connected to interface [chars] in VLAN [dec] with lease [dec] has expired.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPPERMITTEDARP: ARP frame permitted due to DHCP 
snooping binding on interface [chars] vlan [dec] sender mac [chars] sender ip 
[chars] target mac [chars] target ip [chars].

Explanation    [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been permitted. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPPKTFWD: Gracefully forwarding DHCP packet. 
reason:[chars] 

Explanation    Gracefully forwarding DHCP packet. reason [chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPUP: DHCP Daemon Up. 

Explanation    DHCP Daemon was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INFO: [chars] 

Explanation    An event during switchover. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INTFDISABLE: IP Src Guard disabled on intf [chars] 

Explanation    IP Src Guard was disabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INTFENABLE: IP Src Guard enabled on intf [chars] 

Explanation    IP Src Guard was enabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-NONDHCPPKTFWD: Non DHCP packet with src port:[dec] dst 
port:[dec] on intf:[chars] vlan:[dec]. Forwarding on [chars]

Explanation    Non DHCP packet arrived with UDP src/dst ports [dec], [dec] on interface [chars], vlan [dec]. Forwarding the packet on [chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-VLANDISABLE: DHCP Snooping disabled on vlan [dec] 

Explanation    DHCP Snooping was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-VLANENABLE: DHCP Snooping enabled on vlan [dec] 

Explanation    DHCP Snooping was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

DIAGCLIENT Messages

This section contains the DIAGCLIENT messages.

DIAGCLIENT-2

Error Message    DIAGCLIENT-2-DIAG_BOOTUP_COMPLETE: Module <[dec]> Bootup Test 
<[chars]> has reported <[chars]>

Explanation    Bootup Test completed

Recommended Action    Nothing to be done if the test reports SUCCESS otherwise copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information

Error Message     DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <[chars]> has been disabled 
as a part of default EEM action 

Explanation    Informational Syslog

Recommended Action    No action is required.

Error Message     DIAGCLIENT-2-PSS_READ_FAILURE: Read from PSS failed on Module <[dec]>

Explanation    Read operation from PSS store failed

Recommended Action    No action is required.

Error Message     DIAGCLIENT-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]>

Explanation    Write operation on PSS store failed

Recommended Action    No action is required.

DIAGCLIENT-3

Error Message     DIAGCLIENT-3-DIAG_HM_FAIL: Module <[dec]> Health Monitoring Test 
<[chars]> has failed. Please use 'show diagnostic result <target>' to see test 
results

Explanation    A Health Monitoring Test has reported failure

Recommended Action    Ensure the line card is firmly in the slot, reseat if necessary, and attempt to run the test again if the line card is not seated properly in the slot. If the line card was properly seated in the slot, copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information.

Error Message     DIAGCLIENT-3-ONDEMAND_FAIL_EXCESS: Module <[dec]> Test <[chars]> has 
failed more than <[dec]> number of times 

Explanation    Ondemand test has failed more than configured number of times

Recommended Action    Copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information

Error Message     DIAGCLIENT-3-PER_PORT_TEST_FAIL: Module <[dec]> Test <[chars]> has 
failed on Ports <[chars]> Please use 'show diagnostic result <target>' to see test 
results

Explanation    Per Port Test has failed on the above all ports

Recommended Action    No action is required.

DIAGCLIENT-4

Error Message     DIAGCLIENT-4-LC_OFFLINE_FOR_CURR_SLOT: Received LC offline event for 
the current slot:[dec]. Ignoring it 

Explanation    Informational Syslog

Recommended Action    No action is required.

Error Message     DIAGCLIENT-4-MTS_SEND_FAILURE: MTS send failed, mts_opc: [chars], 
dest slot: [dec], dest SAP: [dec], error-id: [hex] 

Explanation    MTS send reports failure

Recommended Action    No action is required.

DIAGCLIENT-5

Error Message     DIAGCLIENT-5-CALLOC_FAILURE: Memory allocation failed 

Explanation    DiagClient process could not allocate memory

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-DIAG_SCHED_COMPLETE: Module <[dec]> Test <[chars]> has 
completed Scheduled Testing 

Explanation    A scheduled Test was completed

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-ONDEMAND_FAIL: Module <[dec]> Test <[chars]> has failed 
in Test_Iteration <[dec]> 

Explanation    The specified test has reported FAILURE in this Iteration

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-ONDEMAND_SUCCESS: Module <[dec]> Test <[chars]> has 
completed successfully in Test_Iteration <[dec]> 

Explanation    The specified test has reported SUCCESS in this Iteration

Recommended Action    No action is required.

DIAGMGR Messages

This section contains the DIAGMGR messages.

DIAGMGR-2

Error Message    DIAGMGR-2-MTS_SEND_FAILURE: MTS send failed, mts_opc: [chars], dest 
slot: [dec], dest SAP: [dec], error-id: [hex] 

Explanation    MTS send reports failure

Recommended Action    No action is required.

Error Message     DIAGMGR-2-PSS_DELETE_FAILURE: Read from PSS failed on Module <[dec]> 

Explanation    Read operation from PSS store failed

Recommended Action    No action is required.

Error Message     DIAGMGR-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]> 

Explanation    Write operation on PSS store failed

Recommended Action    No action is required.

DIAGMGR-3

Error Message     DIAGMGR-3-DIAG_MAJOR_DEFECT: Module <[dec]> Test <[chars]> detected 
a Major Error Please use 'show diagnostic result <target>' to see test results

Explanation    A major error was detected during diagnostic testing

Recommended Action    Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.

Error Message     DIAGMGR-3-DIAG_MINOR_DEFECT: Module <[dec]> Test <[chars]> detected 
a Minor Error Please use 'show diagnostic result <target>' to see test results

Explanation    A minor error was detected during diagnostic testing

Recommended Action    Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information

Error Message     DIAGMGR-3-GET_CURR_SLOT_FAIL: Failed to get the current slot for the 
process. Error:[chars] 

Explanation    The process initialization failed to get the current slot.

Recommended Action    This is an informational message stating that a process initialization failure.

DIAGMGR-4

Error Message     DIAGMGR-4-CURR_SLOT_OFFLINE: Recevied an LC offline event for the 
current slot:[dec]. Ignoring it 

Explanation    The process received an offline event for the slot it is running. Ignoring it.

Recommended Action    This is an informational message stating that an unexpected event has been encountered.

Error Message     DIAGMGR-4-DISRPT_TST_START: Starting Test <[chars]> on Module <[dec]> 
is Disruptive 

Explanation    Starting a Disruptive Test can disturb the system's normal functionality

Recommended Action    Reset target module

Error Message     DIAGMGR-4-FIXED_INTRVL_CHANGED: The users are not allowed to change 
monitoring interval of Test <[chars]>

Explanation    The specified health monitoring test interval is not user-configurable and therefore cannot be changed

Recommended Action    Nothing. The specific health monitoring interval is not user- configurable by design so nothing can be done to change the interval.

DIAGMGR-5

Error Message     DIAGMGR-5-BOOTUP_CONF: Diagnostic Bootup Level: <[chars]>

Explanation    Current Diagnostic BootUp Level being configure or changed

Recommended Action    No action is required.

Error Message     DIAGMGR-5-CALLOC_FAILURE: Memory allocation failure 

Explanation    Memory allocation in a call to malloc/calloc has failed

Recommended Action    No action is required.

Error Message     DIAGMGR-5-CHANGE_ALWAYS_HM: Health Monitoring test <[chars]> in 
Module <[dec]> is a must run and cannot be modified

Explanation    The specified health monitoring test must be run and cannot be disabled

Recommended Action    Nothing. The specific health monitoring test cannot be disabled by design. The system is working properly.

Error Message     DIAGMGR-5-HM_START: Health monitoring test <[chars]> for Module 
<[dec]> 

Explanation    Health Monitoring Test started

Recommended Action    No action is required.

Error Message     DIAGMGR-5-HM_STOP: Disabling health monitoring test <[chars]> for 
Module <[dec]> 

Explanation    Health Monitoring Test has been stopped It can be enabled through the diagnostic monitor..... command

Recommended Action    No action is required.

Error Message     DIAGMGR-5-INTRVL_INCORRECT: Monitoring Interval is less than minimum 
of [dec] seconds required for Module <[dec]> test <[chars]>

Explanation    Health Monitoring cannot be enabled for the specified test because the interval for the test has been incorrectly set

Recommended Action    The system is working properly and no action is required. If you want to specify a smaller testing interval, the error message text provides the lowest possible configurable interval for the specified monitoring interval

Error Message     DIAGMGR-5-MODULE_MISSING: Diagnostic command issued on non-existing 
Module <[dec]> 

Explanation    A line card could not be located in a slot where a diagnostic action was requested

Recommended Action    Ensure the targeted line card is properly seated in the specified slot. If the line card is properly seated, ensure the correct slot was indicated in the command-line interface. If the line card is well-seated and the correct slot was specified, copy the error message exactly as it appears on the screen as well as the output of show tech-support and paste the output into a separate file. Contact your technical support representative with the gathered information

Error Message     DIAGMGR-5-NONHM_AS_HM: The Test <[chars]> cannot be used as health 
monitoring test 

Explanation    Non-HM test cannot be scheduled to run as a Health Monitoring test

Recommended Action    No action is required.

DIAGMGR-6

Error Message     DIAGMGR-6-BOOTUP_DIAG_OK: Module <[dec]>: Passed Online Diagnostics

Explanation    The diagnostic tests did not detect any error on the card.

Recommended Action    This is an informational message stating that the line card passed the diagnostic tests.

Error Message     DIAGMGR-6-BOOTUP_TEST_STARTED: Module <[dec]>: Running [chars] 
Diagnostics

Explanation    Starting bootup testing for above module

Recommended Action    No action is required.

DIAG_PORT_LB Messages

This section contains the DIAG_PORT_LB messages.

DIAG_PORT_LB-2

Error Message    DIAG_PORT_LB-2-LCM_RESP_SEND_FAILURE: LC Inserted request response 
send to Module Manager failed . Error:[chars]

Explanation    Failed to send the response for LC insertion to Module Manager.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-LIF_GET_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed to get Diagnostic LIF id

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-MALLOC_FAILURE: [chars]([dec]) Memory allocation 
failed. 

Explanation    Port Loopback test process could not allocate memory

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-PORTLOOPBACK_TEST_FAIL: Module:[dec] 
Test:PortLoopback failed [dec] consecutive times. Faulty module:[chars] affected 
ports:[chars] Error:[chars]

Explanation    PortLoopback test failed on the module consecutively

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-PROC_INIT_FAILURE: [chars]([dec]) [chars] 
Error:[chars] 

Explanation    Port Loopback test process failed in process initialization

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-REWRITE_ENGINE_LOOPBACK_TEST_FAIL: Module:[dec] 
Test:RewriteEngine Loopback failed [dec] consecutive times. Faulty module:[chars] 
affected ports:[chars] Error:[chars]

Explanation    Rewrite Engine Loopback test failed on the module consecutively

Recommended Action    No action is required.

DIAG_PORT_LB-3

Error Message     DIAG_PORT_LB-3-DIAG_FWD_PATH_SETUP_FAILURE: [chars]. Module:[dec] 
Error:[chars]. 

Explanation    Forwarding path setup for port loopback tests failed

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-DIAG_PKT_SEND_FAILURE: [chars]([dec]) [chars]. 
Error:[chars] 

Explanation    Port Loopback test process failed to send loopback packets.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-FSM_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars] 

Explanation    Port Loopback test process failed in MTS API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-GET_DIAG_BD_FAIL: [chars]([dec]) Failed to get the BD 
for Diag VLAN:[dec]. Error:[chars]. 

Explanation    Failed to get the BD corresponding to the Diag VLAN

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-IFINDEX_LIB_FAILURE: [chars]([dec]) [chars] 
[chars]:[hex] [chars] [chars] 

Explanation    Port Loopback test process failed in if_index library API

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-INVALID_TEST_REQUEST: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to get test request info.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-INVALID_TEST_RUN: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to get the current test run information

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-MTS_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars] 

Explanation    Port Loopback test process failed in MTS API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PDB_LIB_API_ERROR: Failed to [chars]. Error:[dec]. 

Explanation    The port loopback test was not able to get chassis info

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PIXM_LIB_ERROR: [chars]([dec]) Failed to convert 
[chars]:[hex] to [chars]. Error:[chars] 

Explanation    Port Loopback test process failed to convert port ifindex <-> port index.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PORT_CFG_REQ_SEND: [chars]([dec]) Failed to send 
request to configure port ifindex:[dec] for port loopback test

Explanation    Failed to configure/restore the port to do/cleanup port loopback testing

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PORT_CLIENT_LIB_ERROR: [chars]([dec]) [chars]. 
Error:[chars] 

Explanation    Port Loopback test process failed in Port Client API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RESULT_ADD_FAILURE: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to add the port test result

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RESULT_SEND_FAILURE: [chars]([dec]) [chars] 

Explanation    Port Loopback test process failed to send the test results

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RW_ENGINE_LOOPBACK_TEST_SPINE_PATH_FAIL: Module:[dec] 
Test:RewriteEngine Loopback Spine path:[dec] failed [dec] consecutive times. 
Error:[chars]

Explanation    Rewrite Engine Loopback test failed on the spine path consecutively

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-SOCKET_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed in socket operations

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-STATS_LIB_ERROR: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed in stats infra lib API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-TEST_RES_SEND_FAIL: Failed to send [chars] test 
results back to Diagnostics Infrastucture. Error:[chars].

Explanation    The port loopback test was not able to send the test results

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-TIMER_LIB_ERROR: [chars]([dec]) [chars] 

Explanation    Port Loopback test process timer handling failure.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-VLAN_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed to get Diagnostic VLAN info

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-VQI_GET_FAIL: Failed to get the Diag VQi from XBM. 
Error:[chars] 

Explanation    Rewrite Engine Loopback test failed to get the Diag VQi from XBAR Mgr

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-XBM_CFG_REQ_FAIL: Failed to conigure the XBAR mask 
while running the RewriteEngineLoopback test. Error:[chars]. Module:[dec] could 
have gone offline

Explanation    Rewrite Engine Loopback test failed to set the XBAR mask while running the test. The target module could have gone offline

Recommended Action    No action is required.

DIAG_PORT_LB-5

Error Message     DIAG_PORT_LB-5-DIAG_PORT_LB_DISABLED: DIAG_PORT_LB Disabled 

Explanation    DIAG_PORT_LB Service Disabled

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-5-DIAG_PORT_LB_ENABLED: DIAG_PORT_LB Enabled 

Explanation    DIAG_PORT_LB Service nabled

Recommended Action    No action is required.

DMM Messages

This section contains the DMM messages.

DMM-SLOT#-5

Error Message    DMM-SLOT#-5-LOG_ERR_DMM_NEW_NPORT_SRVR_ZONE: Job Id:%Ld VSAN :[dec] 
New N-Port FCID :[hex] Server FCID:[hex] are in the same zone. ALERT!!

Explanation    A New N-Port has come up which is zoned in the same zone as the Server

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_NEW_NPORT_STG_ZONE: Job Id:%Ld VSAN :[dec] 
New N-Port FCID :[hex] Storage FCID:[hex] are in the same zone. ALERT!!

Explanation    A New N-Port has come up which is zoned in the same zone as the Storage

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_SRVR_RSCN: Job Id:%Ld Server N-Port 
pWWN:0x%Lx [chars] 

Explanation    An RSCN event was received for the Server associated with a Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_STG_RSCN: Job Id:%Ld N-Port pWWN:0x%Lx 
Storage:[chars] [chars]

Explanation    An RSCN event was received for the Storage associated with a Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_COMPLETE: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the completion of a Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR_LOST_SSM_PEER_CONNECTION: Job 
Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job due to loss in ip connectivity to peer ssm

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_FINISH: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating Finish-request for a Method-2 Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_START: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the start of a Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_STOP: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating that the Data Migration Job was stopped by Administrator

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_TCP_CONNECTION_DOWN: Job Id:%Ld lost 
connection to peer [chars]. Job may be RESET 

Explanation    Event indicating IP Connectivity loss to peer SSM. Affected Job maybe be RESET

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_COMPLETE: Job Id:%Ld 
NumSession:[dec] 

Explanation    Event indicating the completion of a Data Migration Job Verification

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_ERROR: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job Verification due to an error

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_START: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the start of a Data Migration Job Verification

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_STOP: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job Verification by the user

Recommended Action    No action is required.

DOT1X Messages

This section contains the DOT1X messages.

DOT1X-2

Error Message    DOT1X-2-DOT1X_INIT: Dot1x unable to start 

Explanation    The system failed to create the Dot1x process

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DOT1X-3

Error Message     DOT1X-3-ERR_SPANDST: It is configured as a SPAN Dest port. 

Explanation    Dot1x and SPAN Dest ports are mutually exclusive features.

Recommended Action    Disable SPAN destination port configuration first before reconfiguring Dot1x on the port.

Error Message     DOT1X-3-INVALID_INPUT: Invalid on interface [chars]. 

Explanation    The Dot1x interface parameter is out of the specified range or is invalid.

Recommended Action    Refer to the CLI help documentation to determine the valid 802.1x parameters.

Error Message     DOT1X-3-MEM_UNAVAIL: perform the 802.1X action. 

Explanation    Insufficient system memory is available to perform the Dot1x Authentication.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     DOT1X-3-NOT_DOT1X_CAPABLE: interface [chars] because it is not a 
physical Ethernet interface. 

Explanation    Dot1x Authentication can only be enabled on physical Ethernet interfaces.

Recommended Action    Enable Dot1x Authentication on physical Ethernet interfaces only.

Error Message     DOT1X-3-SM_INIT: Internal error while initializing state machine 
[chars], state [chars]: [chars] 

Explanation    An attempt was made to initialize an invalid state machine.

Recommended Action    Initialize dot1x state machine.

DOT1X-4

Error Message     DOT1X-4-BADEVENT: Event [chars] is invalid for the current state 
[chars]: [chars] [chars] 

Explanation    An attempt was made to post an event to a state machine that is invalid for the current state.

Recommended Action    Initialize dot1x state machine

Error Message     DOT1X-4-MAB_DISABLED_ON_PCM: Interface [chars] is a member of 
portchannel, MAB is not supported on this port 

Explanation    MAB is not supported on portchannel member port

Recommended Action    To enable MAB make sure that port is not member of portchannel

Error Message     DOT1X-4-MAB_DISABLED: Interface [chars] is in Trunk mode, MAB is not 
supported on this port 

Explanation    MAB is not supported on Trunk port

Recommended Action    To enable MAB make sure that port is not in trunk mode

Error Message     DOT1X-4-MULTIHOST_ON_PCM: Interface [chars] is a member of 
portchannel, dot1x host mode will be multi-host and changing it to single-host 
mode won't be supported

Explanation    Current Port is a member of portchannel, so dot1x host mode has to be in multi-host mode.

Recommended Action    To change host mode, ensure that port is not a member of portchannel

Error Message     DOT1X-4-STOPPED: Event [chars] ignored because the state machine is 
stopped: [chars] [chars] 

Explanation    An attempted was made to post an event to a state machine that has already been stopped.

Recommended Action    An internal error has occurred with the state machine. The traceback should indicate the guilty party.

Error Message     DOT1X-4-TO_MULTIHOST: Interface [chars] is in trunk mode, dot1x host 
mode will be multi-host and changing it to single-host mode won't be supported

Explanation    Current Port is in trunk mode, so dot1x host mode has to be in multi-host mode.

Recommended Action    To change host mode, ensure that port is not in trunk mode.

DOT1X-5

Error Message     DOT1X-5-DOT1X_DISABLED: dot1x Disabled 

Explanation    Dot1x Service Disabled

Recommended Action    No action is required.

Error Message     DOT1X-5-DOT1X_ENABLED: dot1x Enabled 

Explanation    Dot1x Service Enabled

Recommended Action    No action is required.

Error Message     DOT1X-5-INVALID_MAC: broadcast or multicast mac address) [chars] is 
trying to authenticate. 

Explanation    Authentication using 802.1x is not allowed for zero, broadcast, and multicast source MAC addresses.

Recommended Action    Connect a Dot1x supported Host to the Dot1x enabled port.

Error Message     DOT1X-5-SECURITY_VIOLATION: New MAC address [chars] is seen on 
interface [chars] in [chars] mode 

Explanation    The port on the interface specified in the error message is configured in single host mode. Any new host that is detected on the interface is treated as a security violation. The port has been Error disabled.

Recommended Action    Ensure that the port is configured to use only one host. Enter the <Cmd>shutdown<Cmd> followed by <CmdBold>no shutdown<CmdBold> command to restart the port.

Error Message     DOT1X-5-SESSION_CREATION: Dot1x authentication session initiated in 
interface [chars] using authentication method [chars]

Explanation    Dot1x authentication session has been created after successful authentication of supplicant

Recommended Action    No action is required.

Error Message     DOT1X-5-SESSION_TERMINATION: Dot1x authentication session in 
interface [chars] using authentication method [chars] is terminated because of 
[chars] and port moved to [chars] state

Explanation    Dot1x authentication session has been terminated

Recommended Action    No action is required.

Error Message     DOT1X-5-STATUS: Dot1x interface [chars] status changed from [chars] 
to [chars] 

Explanation    Dot1x authenticator has changed its internal state

Recommended Action    No action is required.

DPP_DEBUG Messages

This section contains the DPP_DEBUG messages.

DPP_DEBUG-2

Error Message    DPP_DEBUG-2-DPP_CRIT: [DPP[dec]] [chars] 

Explanation    A DPP generated a critical message

Recommended Action    No action is required.

DPVM Messages

This section contains the DPVM messages.

DPVM-2

Error Message    DPVM-2-ALLOC_FAILED: Memory allocation failed for size:[dec] for 
[chars] 

Explanation    Memory allocation failed for size [dec] for [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-2-DPVM_DUPL_REJECT: [chars] 

Explanation    Rejected duplicate pwwn query

Recommended Action    Dpvm overwrite-duplicate-pwwn

DPVM-3

Error Message     DPVM-3-DB_ERR: [chars] 

Explanation    An error occured during an DPVM database operation. [chars] indicates the reason for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message    DPVM-3-DDAS_MODE_INVALID: [chars] 

Explanation    DDAS mode Invalid. [chars]

Recommended Action    Flip DDAS mode

Error Message     DPVM-3-INIT_FAIL: [chars] 

Explanation    An error happened during DPVM Initialization. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-3-MTS_ERR: [chars] 

Explanation    An error occured in processing of an MTS message. [chars] indicates the error that occured

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-3-PSS_ERR: [chars] 

Explanation    An error occured during an DPVM PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DPVM-4

Error Message     DPVM-4-ACTIVATION_FAIL: [chars] 

Explanation    Activation of DPVM device mappings failed due to [chars]

Recommended Action    Correct the error and reactivate database again

Error Message     DPVM-4-FEATURE_DISABLED: [chars] 

Explanation    DPVM is unavailable and disabled now

Recommended Action    No action is required.

DPVM-6

Error Message     DPVM-6-FEATURE_ENABLED: [chars] 

Explanation    DPVM is available and enabled now

Recommended Action    No action is required.

Error Message     DPVM-6-INFO: [chars] 

Explanation    An event happened that affects DPVM. [chars] indicates the event

Recommended Action    No action is required.

DSTATS Messages

This section contains the DSTATS messages.

DSTATS-2

Error Message    DSTATS-2-PSS_INIT_FAIL: pss initialization failed due to error: [hex] 

Explanation    Dstats process pss initialization failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

DSTATS-3

Error Message    DSTATS-3-PSS_CREATE_FAIL: pss create runtime database failed due to 
error: [hex] 

Explanation    Dstats process pss create runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed 
due to error: [hex] 

Explanation    Dstats process pss delete runtime entry key [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to 
error: [hex] 

Explanation    Dstats process pss set runtime max key failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed due to 
error: [hex] 

Explanation    Dstats process pss set runtime max value failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_OPEN_FAIL: pss open runtime database failed due to error: 
[hex] 

Explanation    Dstats process pss open runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_RELOAD_FAIL: pss reload runtime database failed due to 
error: [hex] 

Explanation    Dstats process pss reload runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_SNAPSHOT_DEBUG_FAIL: pss snapshot runtime debug to 
uri:[chars] failed due to error: [hex] 

Explanation    Dstats process pss snapshot of runtime debug to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_SNAPSHOT_FAIL: pss snapshot runtime to uri:[chars] 
failed due to error: [hex] 

Explanation    Dstats process pss snapshot of runtime to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_STORE_FAIL: pss store runtime entry key:[hex] val:[hex] 
failed due to error: [hex] 

Explanation    Dstats process pss store runtime entry key [hex] value [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

ELTMC Messages

This section contains the ELTMC messages.

ELTMC-SLOT#-2

Error Message    ELTMC-SLOT#-2-ELTMC_INTERFACE_INTERNAL_ERROR: Internal error: 
[chars]:[chars], collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTERNAL_ERROR: Internal error: [chars], collect 
output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_NOT_FOUND: Interface [chars] not found in 
ELTM database [chars] 

Explanation    ELTM database doesn't have the interface.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_NOT_SUPP: Interface [chars] not supported by 
ELTM [chars] 

Explanation    ELTM doesn't support the interface for the specified operation

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_TO_LTL: Failed to get LTL for interface 
[chars] return status [chars] 

Explanation    ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_TO_SLOT: Failed to get slot for interface 
[chars] return status [chars] 

Explanation    ELTM Failed to get Slot for interface. Port-channels and L2 Learning might be effected

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_INTF: Failed to allocate L2 LIF 
entries in forwarding engine for interfac [chars] 

Explanation    ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding for the interface

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_VDC: Failed to allocate L2 LIF 
entries in forwarding engine 

Explanation    ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding in this VDC

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L3_INGRESS_LIF_ALLOC_FAIL_INTF: Failed to 
allocate L3 Ingress LIF entries in forwarding engine for interfac [chars] 

Explanation    ELTM Failed to allocate L3 Ingress LIF entries in forwarding engine. This will effect Layer 3 forwarding for the interface

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_RSVD_VLAN: Failed to get the reserved vlans. 
Failed with error [chars] 

Explanation    ELTM Failed to get the reserved vlan's. This will effect multicast forwarding on SVI interfaces

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_VLAN_INTERNAL_ERROR: Internal error: VLAN 
[dec]:[chars], collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

ELTM Messages

This section contains the ELTM messages.

ELTM-2

Error Message    ELTM-2-INTERFACE_INTERNAL_ERROR: Internal error: [chars]:[chars], 
collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTM-2-INTERNAL_ERROR: Internal error: [chars], collect output of 
show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_NOT_FOUND: Interface [chars] not found in ELTM database 
[chars] 

Explanation    ELTM database doesn't have the interface.

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_NOT_SUPP: Interface [chars] not supported by ELTM [chars] 

Explanation    ELTM doesn't support the interface for the specified operation

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_TO_LTL: Failed to get LTL for interface [chars] return 
status [chars] 

Explanation    ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine

Recommended Action    No action is required.

ELTM-6

Error Message     ELTM-6-ELTM_MTS_SEND_FAILED: Failed to send MTS message errno [hex] 
opcode [dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

EOU Messages

This section contains the EOU messages.

EOU-2

Error Message    EOU-2-PBACL_APPLICATION_FAILURE: [chars] of host [chars] to/from pbacl 
group [chars] failed. Error : [chars] 

Explanation    Failure of host addition/deletion to/from pbacl group

Recommended Action    Please verify the addition/deletion of the host using the cli show object-group. If it was a delete request that failed, manual deletion of the host from the group is recommended

EOU-5

Error Message     EOU-5-L2NAC_DISABLED: EOU Disabled 

Explanation    Service EOU Disabled

Recommended Action    No action is required.

Error Message     EOU-5-L2NAC_ENABLED: EOU Enabled 

Explanation    Service EOU enabled

Recommended Action    No action is required.

EOU-6

Error Message     EOU-6-AAA_DOWN: Default Policy ip: [chars]:retained 

Explanation    Policy retained

Recommended Action    No action is required.

Error Message     EOU-6-AUTHTYPE: Authtype: ip: [chars] Authtype:[chars] 

Explanation    Authentication type

Recommended Action    No action is required.

Error Message     EOU-6-BAD_PKT: Bad Packet: ip: [chars] Why: [chars] 

Explanation    Bad Packet because of reason specified

Recommended Action    No action is required.

Error Message     EOU-6-CTA: CTA: ip: [chars] status(detected/not detected): [chars] 

Explanation    CTA detected or not

Recommended Action    No action is required.

Error Message     EOU-6-IDENTITY_MATCH: Identity Match: ip: [chars] Policy: [chars] 

Explanation    Identity Matched or not

Recommended Action    No action is required.

Error Message     EOU-6-PBACL_APPLICATION_STATUS: [chars] of host [chars] to/from pbacl 
group [chars] succeeded 

Explanation    Status of host addition/deletion to pbacl group

Recommended Action    No action is required.

Error Message     EOU-6-POLICY: Policy on ip: [chars]: [chars]: [chars] 

Explanation    Policy applied

Recommended Action    No action is required.

Error Message     EOU-6-POSTURE: Posture:ip: [chars] Status: [chars], Interface: 
[chars] 

Explanation    Posture of host

Recommended Action    No action is required.

Error Message     EOU-6-SESSION: Session ip: [chars] Action:[chars] , Interface: 
[chars] 

Explanation    Session detected

Recommended Action    No action is required.

Error Message     EOU-6-SOCKET: Service eou on port: [dec] 

Explanation    Eou using above port

Recommended Action    No action is required.

Error Message     EOU-6-SQ_EAP_MSG: Status Query: ip: [chars] status: [chars] 

Explanation    Status query state

Recommended Action    No action is required.

Error Message     EOU-6-UNKN_EVENT_ERR: Unknow Event Err: ip: [chars] Message: [chars] 

Explanation    Error due to unknown event

Recommended Action    No action is required.

Error Message     EOU-6-VERSION_MISMATCH: Eou version mismatch ip: [chars] and version 
[dec] 

Explanation    Eou version mismatch

Recommended Action    No action is required.

EOU-7

Error Message     EOU-7-EOU_DISABLED_INTF: eou disabled on interface [chars] 

Explanation    Eou service disabled on interface

Recommended Action    No action is required.

Error Message     EOU-7-EOU_ENABLED_INTF: eou enabled on interface [chars] 

Explanation    Eou service enabled on interface

Recommended Action    No action is required.

EPP Messages

This section contains the EPP messages.

EPP-5

Error Message    EPP-5-EPP_FAILURE: Interface [chars] EPP Failure 

Explanation    Trunk protocol failed

Recommended Action    'show epp internal event-history err' will indicate the errors encountered

Error Message     EPP-5-EPP_LOOPBACK: Interface [chars] is looped back to the same 
switch 

Explanation    The interface is looped back to another interface on the same switch

Recommended Action    Check the connectivity of this interface and ensure that it is connected to another switch

ETH-PORT-SEC Messages

This section contains the ETH-PORT-SEC messages.

ETH-PORT-SEC-2

Error Message    ETH-PORT-SEC-2-ETH_PORT_SEC_SECURITY_VIOLATION_ANOTHER_PORT: Host 
[chars] bound to Port [chars] in Vlan [dec] is trying to access Port [chars] in 
Vlan [dec] 

Explanation    Moved the port to violation state due to a mac address seen on one port being seen on another

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-2-ETH_PORT_SEC_SECURITY_VIOLATION_MAX_MAC_VLAN: Port 
[chars] moved to [chars] state as host [chars] is trying to access the port in 
vlan [dec] 

Explanation    Moved the port to violation state due to exceeding address count

Recommended Action    No action is required.

ETH-PORT-SEC-3

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_CONFIG_MAC_FAILED: Failed to configure 
MACs 

Explanation    Failed to configure MACs

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_INVALID_VLAN: Invalid VLAN configuration 

Explanation    Invalid VLAN configuration

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_DISABLE: Unable to disable 
eth_port_sec [chars]. 

Explanation    Unable to disable eth_port_sec Service

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_ENABLE: Unable to enable 
eth_port_sec [chars]. 

Explanation    Unable to enable eth_port_sec Service

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_VIOL_UPDATE_FAILED: Failed to update 
violation mode 

Explanation    Failed to update violation mode

Recommended Action    No action is required.

ETH-PORT-SEC-5

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_AGE_TIME_EXPIRY: Age Time expired for 
host [chars] in VLAN [dec] in port [chars] 

Explanation    Age time expired for host

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_DISABLED: eth_port_sec Disabled on port 
[chars] 

Explanation    Eth_port_sec Service Disabled

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_DYNAMIC_MAC_ADDRESS_CLEARED: Dynamic MAC 
addresses for port [chars] cleared 

Explanation    Dynamic MAC address for port cleared

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_ENABLED: eth_port_sec Enabled on port 
[chars] 

Explanation    Eth_port_sec Service Enabled

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_ADDITION: A new Host [chars] learnt 
on Port [chars] in Vlan [dec] 

Explanation    A new host is learnt on a port

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_DELETION: Host [chars] bound to 
secure port [chars] in Vlan [dec] has been removed 

Explanation    A host has been removed

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_MAX_LIMIT_EXCEED: Max Addr per port 
config cannot be accepted as it will violate the System Max limit. [chars] 

Explanation    System wide Max Limit Exceeds

Recommended Action    No action is required.

ETHPORT Messages

This section contains the ETHPORT messages.

ETHPORT-2

Error Message    ETHPORT-2-IF_CRITICAL_FAILURE: (Debug syslog)Critical failure: 
[chars], [chars] 

Explanation    There was a critical failure in the component.

Recommended Action    Please follow instructions on the syslog.

Error Message     ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error 
disabled. Reason:[chars]) 

Explanation    The interface encountered an error while configuring it

Recommended Action    Collect more information about failed interface using command 'show port internal all interface [char]'. In most cases, you can recover using a 'shutdown' followed a 'no shutdown' on the interface or removing and re-inserting the fibre optic cable.

Error Message     ETHPORT-2-IF_ERROR_SHUT_LAN_NO_DCX: Shutting lan on interface [chars] 
that doesn't connect to a DCBX capable adaptor. 

Explanation    Shutting lan on interface that doesn't connect to a DCBX capable adaptor.

Recommended Action    No action is required.

Error Message     ETHPORT-2-IF_SEQ_ERROR: Error ([chars]) while communicating with 
component [chars] for opcode [chars] ([chars]) 

Explanation    Some component returned system error as a response to one of the port event sequence.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETHPORT-2-SEQ_TIMEOUT: Component [chars] timed out on response to 
opcode [chars] ([chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETHPORT-2-SYSLOG_ETHPM_CRITICAL: Critical failure: [chars] 

Explanation    There was a critical failure in the component.

Recommended Action    Please collect system tech-support

ETHPORT-3

Error Message     ETHPORT-3-IF_DOWN_CHANNEL_ERR_DISABLED: Interface [chars] is down 
(Channel error disabled) 

Explanation    This interface belongs to a PortChannel and the PortChannel is error disabled

Recommended Action    Perform 'shut' and 'no shutdown' on the PortChannel interface that it belongs to

Error Message     ETHPORT-3-IF_ERROR_VLANS_REMOVED: VLANs [chars] on Interface [chars] 
are removed from suspended state. 

Explanation    The VLANs on an interface are being removed from the suspended state

Recommended Action    No action is required.

Error Message     ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs [chars] on Interface 
[chars] are being suspended. (Reason: [chars]) 

Explanation    The VLANs on an interface are being suspended due to some protocol action

Recommended Action    No action is required.

Error Message     ETHPORT-3-IF_SFP_ALARM: Interface [chars], [chars] 

Explanation    There was an alarm on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     ETHPORT-3-IF_SFP_ERROR: Interface [chars], [chars] 

Explanation    There was an error on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER_VENDOR: Transceiver vendor 
([hex] [hex] [hex]) for interface [chars] is not supported 

Explanation    The transceiver vendor for the interface specified in the error message is not supported

Recommended Action    Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced

Error Message     ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver on interface 
[chars] is not supported 

Explanation    The transceiver for the interface specified in the error message is not a Cisco supported module

Recommended Action    Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced

ETHPORT-4

Error Message     ETHPORT-4-IF_SFP_WARNING: Interface [chars], [chars] 

Explanation    There was an warning on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

ETHPORT-5

Error Message     ETHPORT-5-IF_BANDWIDTH_CHANGE: Interface [chars],bandwidth changed to 
[chars] Kbit 

Explanation    Bandwidth of the interface (port channel) has changed and this change is updated

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is down 
(Administratively down) 

Explanation    Interface has been configured to be administratively down

Recommended Action    Perform 'no shutdown'

Error Message     ETHPORT-5-IF_DOWN_CFG_CHANGE: Interface [chars] is down(Config 
change) 

Explanation    FCIP interface temporarily down due to reconfiguration

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_CHANNEL_ADMIN_DOWN: Interface [chars] is down 
(Channel admin down) 

Explanation    This interface belongs to a PortChannel and the PortChannel is configured to be administratively down

Recommended Action    Perform 'no shutdown' on the PortChannel interface that it belongs to

Error Message     ETHPORT-5-IF_DOWN_CHANNEL_MEMBERSHIP_UPDATE_IN_PROGRESS: Interface 
[chars] is down (Channel membership update in progress) 

Explanation    The interface belongs to a PortChannel and a configuration is being attempted on the interface while there is a configuration in progress on the PortChannel

Recommended Action    Retry the configuration again

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_ADDR_ASSIGN_FAILURE_ISOLATION: Interface 
[chars] is down (Isolation due to domain id assignment failure) 

Explanation    Isolated due to a failure while assigning a domain

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_INVALID_RCF_RECEIVED: Interface [chars] is 
down (Isolation due to invalid fabric reconfiguration) 

Explanation    Invalid RCF received

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED: Interface [chars] is down 
(Isolation due to domain manager disabled) 

Explanation    Isolated due to domain manager being disabled

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE: Interface 
[chars] is down (Isolation due to domain manager other side not responding) 

Explanation    Remote end domain manager not responding

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED: Interface 
[chars] is down (Isolation due to domain other side eport isolated) 

Explanation    Isolating this interface due to the remote end being isolated

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION: Interface [chars] is down 
(Isolation due to domain overlap) 

Explanation    Isolated due to domain overlap

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ELP_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ELP failure) 

Explanation    ELP failed on the interface

Recommended Action    Check the output of 'show port internal info' in the 'ELP failure reason' field

Error Message     ETHPORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error 
Disabled - EPP Failure) 

Explanation    Trunk protocol failed

Recommended Action    'show port internal event-history msgs' will indicate the trunk protocol exchanges to determine why it failed

Error Message     ETHPORT-5-IF_DOWN_ESC_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ESC failure) 

Explanation    ESC failed on the interface

Recommended Action    Check the output of 'show port internal event-history' to determine the ESC protocol exchanges to determine how it failed

Error Message     ETHPORT-5-IF_DOWN_ETH_IF_DOWN: Interface [chars] is down(Tunnel port 
src interface down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected, the interface is administratively enabled

Error Message     ETHPORT-5-IF_DOWN_ETH_LINK_DOWN: Interface [chars] is down(Tunnel 
port src interface link down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected and the remote end is also active

Error Message     ETHPORT-5-IF_DOWN_FCOT_NOT_PRESENT: Interface [chars] is down (FCOT 
not present) 

Explanation    The FCOT has been removed

Recommended Action    Insert an FCOT

Error Message     ETHPORT-5-IF_DOWN_FCOT_VENDOR_NOT_SUPPORTED: Interface [chars] is 
down (Error disabled - Fcot vendor not supported) 

Explanation    Fcot inserted is not a supported one

Recommended Action    Please contact customer support for a list of authorized transceiver vendors

Error Message     ETHPORT-5-IF_DOWN_HW_FAILURE: Interface [chars] is down (Hardware 
Failure) 

Explanation    The module's hardware has failed

Recommended Action    Collect more information about failed module using command 'show module internal all module'

Error Message     ETHPORT-5-IF_DOWN_INACTIVE: Interface [chars] is down (Inactive) 

Explanation    The port VSAN has been suspended or deleted

Recommended Action    Assign a new active port VSAN to the interface

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_MODE: Interface [chars] is down 
(Error disabled - Incompatible admin port mode) 

Explanation    The configured mode is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the list of modes supported on this interface

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBBCREDIT: Interface [chars] 
is down (Error disabled - Incompatible admin port rxbbcredit) 

Explanation    The configured receive B2B credit size is not supported

Recommended Action    Get the allowed receive B2B credit size from 'show port internal info'

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBUFSIZE: Interface [chars] is 
down (Error disabled - Incompatible admin port rxbufsize) 

Explanation    The configured receive buffer size is not supported

Recommended Action    Get the allowed receive buffer size from 'show port internal info'

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_SPEED: Interface [chars] is down 
(Error disabled - Incompatible admin port speed) 

Explanation    The configured speed is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the range of speed supported on this interface

Error Message     ETHPORT-5-IF_DOWN_INITIALIZING: Interface [chars] is down 
(Initializing) 

Explanation    The interface is in the process of coming up

Recommended Action    If the interface is stuck in this state for a while, check the output of 'show port internal event-history' to determine what it is waiting for

Error Message     ETHPORT-5-IF_DOWN_INTERFACE_REMOVED: Interface [chars] is down 
(Interface removed) 

Explanation    Interface removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface [chars] is down (Link 
failure) 

Explanation    The physical link has gone down

Recommended Action    Ensure that the cable is connected and the remote end is not shut down

Error Message     ETHPORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE: Interface [chars] is down 
(Diag failure) 

Explanation    Diag failed on the interface

Recommended Action    Collect more information about failed interface using command 'attach module' to connect to module

Error Message     ETHPORT-5-IF_DOWN_LOOPBACK_ISOLATION: Interface [chars] is down 
(Isolation due to port loopback to same switch) 

Explanation    The interface is looped back to another interface on the same switch

Recommended Action    Check the connectivity of this interface and ensure that it is connected to another switch

Error Message     ETHPORT-5-IF_DOWN_MODULE_REMOVED: Interface [chars] is down (module 
removed) 

Explanation    Interface is down because the module was removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_NONE: Interface [chars] is down (None) 

Explanation    There is no apparent reason the interface is down

Recommended Action    Collect more information about port using command 'show port internal info/event-history' to determine why it went down

Error Message     ETHPORT-5-IF_DOWN_NON_PARTICIPATING: Interface [chars] is down (Non 
participating) 

Explanation    The loop port has been put into non participating mode

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_OFFLINE: Interface [chars] is down (Offline) 

Explanation    The interface has been placed into the offline state

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PARENT_ADMIN_DOWN: Interface [chars] is down 
(Parent interface down) 

Explanation    Parent interface is down

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PEER_CLOSE: Interface [chars] is down(TCP conn. 
closed by peer) 

Explanation    The FCIP peer connected to this interface closed the TCP connection

Recommended Action    This command will provide the peer IP address of this FCIP interface: show interface. Check to see why the peer closed the TCP connection

Error Message     ETHPORT-5-IF_DOWN_PEER_RESET: Interface [chars] is down(TCP conn. 
reset by peer) 

Explanation    TCP connection to the FCIP peer got reset

Recommended Action    The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Check to see why the peer reset the TCP connection

Error Message     ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface [chars] is 
down (No operational members) 

Explanation    This is a PortChannel interface and all its members are operationally down

Recommended Action    Enable at least one of the PortChannel's members

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_DEINHERIT_ERR: Interface [chars] is 
down (port-profile de-inherit error) 

Explanation    Interface is down because the existing port-profile on the interface failed to de-inherit properly

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_INHERIT_ERR: Interface [chars] is down 
(port-profile inherit error) 

Explanation    Interface is down because the associated port-profile failed to inherit properly

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_NOT_FOUND: Interface [chars] is down 
(port-profile not found) 

Explanation    Interface is down because there is no associated port-profile

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_VSAN_MISMATCH_ISOLATION: Interface [chars] is 
down (Isolation due to port vsan mismatch) 

Explanation    Isolated due to a mismatch in the configured port VSAN of the local and remote ends

Recommended Action    Configure the port VSAN of the local and remote interfaces to be the same and perform a 'shutdown' and a 'no shutdown'

Error Message     ETHPORT-5-IF_DOWN_RCF_IN_PROGRESS: Interface [chars] is down (RCF in 
progress) 

Explanation    There is an RCF in progress

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface [chars] is down (Port 
software failure) 

Explanation    The software servicing the data path on the port has failed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SRC_MOD_NOT_ONLINE: Interface [chars] is 
down(Tunnel source module not online) 

Explanation    Module that has the tunnel source port of this FCIP interface is not fully online

Recommended Action    The module that has the tunnel src port is coming online. Please use show mod to find module status

Error Message     ETHPORT-5-IF_DOWN_SRC_PORT_NOT_BOUND: Interface [chars] is down 
(Tunnel port src interface unbound) 

Explanation    Tunnel port source interface unbound

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SRC_PORT_REMOVED: Interface [chars] is down(Tunnel 
src port removed) 

Explanation    Tunnel source port of this FCIP interface has been removed

Recommended Action    The src interface with ip address that matches the ip address of the bound entity is removed. This happens normally due to the module on which the src interface exists is removed

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down 
(Suspended due to incompatible mode) 

Explanation    This interface belongs to a PortChannel and operational mode of the interface is different from that of the PortChannel

Recommended Action    Change the mode and the trunking mode of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down 
(Suspended due to incompatible speed) 

Explanation    This interface belongs to a PortChannel and operational speedode of the interface is different from that of the PortChannel

Recommended Action    Change the speed of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_WWN: Interface [chars] is down 
(Suspended due to incompatible remote switch WWN) 

Explanation    This interface belongs to a PortChannel and remote switch WWN of the interface is different from that of the PortChannel

Recommended Action    Ensure that this interface is connected to the same remote switch as all the other interfaces in the PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED: Interface [chars] is down (Suspended) 

Explanation    This interface belongs to a PortChannel and has been suspended due to an error while bringing it up

Recommended Action    Perform a 'shutdown' and a 'no shutdown'. If this happens again obtain output of 'show port internal info/event-history' on the interface

Error Message     ETHPORT-5-IF_DOWN_TCP_KEEP_ALIVE_EXPIRED: Interface [chars] is 
down(TCP conn. closed - Keep alive expired) 

Explanation    TCP session to the FCIP peer got closed due to loss of TCP keep alive

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_TCP_MAX_RETRANSMIT: Interface [chars] is down(TCP 
conn. closed - retransmit failure) 

Explanation    Interface is down due to maximum retransmission failure

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_TCP_PERSIST_TIMER_EXPIRED: Interface [chars] is 
down(TCP conn. closed - Persist timer expired) 

Explanation    TCP session to the FCIP peer closed because TCP persist timer expired

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_UPGRADE_IN_PROGRESS: Interface [chars] is down 
(Linecard upgrade in progress) 

Explanation    Upgrade of the linecard software is in progress

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VEM_UNLICENSED: Interface [chars] is down (VEM 
unlicensed) 

Explanation    Interface is down because VEM is unlicensed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VRF_UNUSABLE: Interface [chars] is down (Vrf down) 

Explanation    The vrf for which this interface is a member is removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION: Interface [chars] is down 
(Isolation due to vsan mismatch) 

Explanation    This is a trunking interface and the VSANs configured do not match with the VSANs configured on the remote end

Recommended Action    Check the VSANs configured on the local end with the remote end

Error Message     ETHPORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION: Interface [chars] is 
down (Isolation due to zone merge failure) 

Explanation    Isolated due to a failure during zone merge

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION: Interface [chars] 
is down (Isolation due to remote zone server not responding) 

Explanation    Isolated due to remote zone server not responding

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DUPLEX: Interface [chars], operational duplex mode 
changed to [chars] 

Explanation    Operational duplex mode has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_HARDWARE: Interface [chars], hardware type changed to 
[chars] 

Explanation    There was a change in the hardware characteristic of an interface, such as a transceiver module plugged in or removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_RX_FLOW_CONTROL: Interface [chars], operational Receive 
Flow Control state changed to [chars] 

Explanation    Operational receive flow control has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_TRUNK_DOWN: Interface [chars], vlan [chars] down 

Explanation    Interface [chars] is trunking, VLANs [chars] are down

Recommended Action    The following commands will help determine why this VSAN is down on this interface: show interface, show port internal info interface VSAN, show port internal event-history interface vsan

Error Message     ETHPORT-5-IF_TRUNK_UP: Interface [chars], vlan [chars] up 

Explanation    Interface [chars] is trunking, VLANs [chars] are up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_TX_FLOW_CONTROL: Interface [chars], operational Transmit 
Flow Control state changed to [chars] 

Explanation    Operational transmit flow control has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_UP: Interface [chars] is up [chars] 

Explanation    Interface is up in mode specified, if applicable

Recommended Action    No action is required.

Error Message     ETHPORT-5-SPEED: Interface [chars], operational speed changed to 
[chars] 

Explanation    Operational speed has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-STORM_CONTROL_ABOVE_THRESHOLD: Traffic in port [chars] 
exceeds the configured threshold [chars] 

Explanation    Traffic on specified port is beyond the configured storm-control threshold, and the excess traffic is being dropped

Recommended Action    Identify source of traffic storm

Error Message     ETHPORT-5-STORM_CONTROL_BELOW_THRESHOLD: Traffic in port [chars] has 
fallen below the configured threshold [chars] 

Explanation    Traffic on specified port has returned to within configured storm-control threshold

Recommended Action    No action is required.

ETH_PORT_CHANNEL Messages

This section contains the ETH_PORT_CHANNEL messages.

ETH_PORT_CHANNEL-1

Error Message    ETH_PORT_CHANNEL-1-LC_CFG_FAILURE: configuring module [dec] failed 
[[chars]] 

Explanation    Module configuration failed

Recommended Action    Module will be automatically reset

Error Message     ETH_PORT_CHANNEL-1-MALLOC_FAILED: cannot allocate memory (size [dec]) 

Explanation    No enough memory

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-1-MAP_PARAM_FAILURE: mapping parameter failed for 
[chars] [[chars]] 

Explanation    Parameter mapping failed

Recommended Action    Specified service is misbehaving; check its status

Error Message     ETH_PORT_CHANNEL-1-MCAST_SEND_FAILURE: failed to send multicast 
[chars]: [chars] 

Explanation    Failed to send a multicast message to all modules, usually because some module went down

Recommended Action    Run show port-channel consistency to check consistency

ETH_PORT_CHANNEL-2

Error Message     ETH_PORT_CHANNEL-2-RESET_MODULE: reset module [dec] for not 
responding or returning error 

Explanation    A module is reset for not responding or returning error

Recommended Action    No action is required.

ETH_PORT_CHANNEL-3

Error Message     ETH_PORT_CHANNEL-3-ALL_DROP_TIMEOUT: Some component(s) timed out on 
dropping notif:[chars] (for:[chars]); Please collect <show system internal mts 
buffers details> 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-COMPAT_CHECK_FAILURE: [chars] is not compatible 

Explanation    Compatibility check failed when adding ports to port-channel

Recommended Action    Make sure the compatibility parameters are consistent while adding ports to port-channel, or use force option

Error Message     ETH_PORT_CHANNEL-3-GENERAL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-LACP_ERROR: [chars] [chars] 

Explanation    LACP error

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send [chars] to sap 
[dec]: [chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-NUM_ACTIVE_PORTS_ERROR: Port-channel:[chars] 
active_nports [dec]; No member is active; Please collect <show tech-support 
port-channel/ethpm> 

Explanation    Port-channel num active ports error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_HWCFG_FAIL_ERROR: Port-channel:[chars] 
mbr:[chars] SAP [dec] returned error [chars] for opc [chars]; if lacp port-channel 
please collect <show tech-support lacp all> or please collect <show tech-support 
port-channel/ethpm>

Explanation    Port-channel hwcfg fail error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_INTERNAL_ERROR: Port-channel:[chars] 
mbr:[chars]; if lacp port-channel please collect <show tech-support lacp all> or 
please collect <show tech-support port-channel/ethpm>

Explanation    Port-channel internal error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_PORT_DOWN_IN_PC_UP_ERROR: 
Port-channel:[chars] mbr:[chars]; if lacp port-channel please collect <show 
tech-support lacp all> or please collect <show tech-support port-channel/ethpm>

Explanation    Port-channel port down in pc_up. No bundle member down

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PORT_CHANNEL_NOT_FOUND: [chars] is not found 

Explanation    Cannot find port-channel in its database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-RSP_TIMEOUT: Component [chars] timed out on 
response to opcode:[chars] (for:[chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-TIMEOUT: timed out after [dec] seconds [type 
[chars], state [chars]] 

Explanation    Some operation timed out

Recommended Action    Run show port-channel consistency to check all module connectivity and consistency

ETH_PORT_CHANNEL-4

Error Message     ETH_PORT_CHANNEL-4-PORT_CFG_DELETED: [chars] removed from [chars] 
(different module inserted) 

Explanation    Port is removed from a port-channel because a different module was inserted to the same slot

Recommended Action    You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.

Error Message     ETH_PORT_CHANNEL-4-PORT_INDIVIDUAL: port [chars] is operationally 
individual 

Explanation    The port is operating as an individual link even though it is locally or remotely configured to be part of a port channel

Recommended Action    Check the configuration of the port locally and remotely to ensure that it can operate as part of a port channel

Error Message     ETH_PORT_CHANNEL-4-PORT_NOT_FOUND: port [chars] is not part of 
port-channel 

Explanation    Cannot find the port in port-channel database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-4-RACE_WARN: [chars] 

Explanation    Warning of possible race condition

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-4-UNEXPECTED_RESPONSE: unexpected response [chars] 
from [chars] 

Explanation    Received an unexpected response and discarded

Recommended Action    No action is required.

ETH_PORT_CHANNEL-5

Error Message     ETH_PORT_CHANNEL-5-AUTO_CREATE_FAILURE: [chars] [chars] 

Explanation    Auto create process on the port failed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-CREATED: [chars] created 

Explanation    A port-channel is created

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-DELETED: [chars] deleted 

Explanation    A port-channel is deleted

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-FOP_CHANGED: [chars]: first operational port 
changed from [chars] to [chars] 

Explanation    The first operational port in a port-channel is changed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is 
down (Suspended due to incompatible mode 

Explanation    Compatibility check failed when adding ports to port-channel

Recommended Action    Make sure the compatibility parameters are consistent between the ports and the port-channel

Error Message     ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is 
down (Suspended due to incompatible speed 

Explanation    Operational compatibility check failed on the port in a port-channel

Recommended Action    Make sure the compatibility parameters are consistent between the ports and the port-channel

Error Message     ETH_PORT_CHANNEL-5-MAX_CHANNEL_DISALLOWED: Module failed to come 
online because port channel interface <port-channel number> greater than [dec] is 
present 

Explanation    The port-channel number configured on the switch is larger than 128

Recommended Action    Delete the set of port channel interface <port-channel interface> which is greater than 128

Error Message     ETH_PORT_CHANNEL-5-OPINPROGRESS_TIMEOUT: [chars] operation in 
progress has timed out 

Explanation    Port-channel operation in progress has timed out

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PCM_CHANNEL_GRP_ID_DEPRECATED: channel-group <id> 
command is deprecated. Please configure channel through port-profile using 
channel-group auto command. 

Explanation    Channel-group <id> command is deprecated. Please configure channel through port-profile using \channel-group auto\ command.

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PCM_ROLLBACK_MAX_PORTS_EXCEEDED: Max ports per 
channel exceeded while trying to create port-channel [dec]. Rollback will be 
performed. 

Explanation    No action is required.

Recommended Action    Port-channel

Error Message     ETH_PORT_CHANNEL-5-PCM_ROLLBACK: Rollback for Port Channel [dec], 
module [dec] 

Explanation    Channel creation failed. Rollback has been performed.

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_ADDED: [chars] added to [chars] 

Explanation    Ports are added to a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_DOWN: [chars]: [chars] is down 

Explanation    Port goes down in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY_DOWN: [chars]: hot-standby port 
[chars] is down 

Explanation    Port-channel hot-standby member goes down

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY: [chars]: [chars] goes to 
hot-standby 

Explanation    Port goes to hot-standby in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_INDIVIDUAL_DOWN: individual port [chars] is 
down 

Explanation    Port-channel member operating in individual mode goes down

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_REMOVED: [chars] removed from [chars] 

Explanation    Ports are removed from a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_SUSPENDED: [chars]: [chars] is suspended 

Explanation    Port is suspended in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_UP: [chars]: [chars] is up 

Explanation    Port comes up in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_CHANGE: Interface [chars] in 
port-channel[dec] subgroup-id changed from [dec] to [dec] 

Explanation    The port's subgroup-id got changed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_ADDED: Interface [chars] is added 
to port-channel[dec] with subgroup id [dec] 

Explanation    The port is added to port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_REMOVED: Interface [chars] is 
removed from port-channel[dec] with subgroup id [dec] 

Explanation    The port is removed from port-channel

Recommended Action    No action is required.

ETH_PORT_CHANNEL-6

Error Message     ETH_PORT_CHANNEL-6-RESYNC: resyncing [chars] with all modules 

Explanation    Resync modules with sup after an error or switchover

Recommended Action    No action is required.

ETH_PORT_CHANNEL-7

Error Message     ETH_PORT_CHANNEL-7-GSYNC_DONE: global synchronization is done 

Explanation    Port-channel manager finished global synchronization

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-GSYNC_REQ: requesting global synchronization 

Explanation    Port-channel manager requested a global synchronization from active sup

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_ACTIVE: started in active mode 

Explanation    Port-channel manager started in active mode

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_DEFAULT: started with default configuration 

Explanation    Port-channel manager started with default configuration

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STANDBY: started in standby mode 

Explanation    Port-channel manager started in standby mode

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STATEFUL: started statefully 

Explanation    Port-channel manager started with running configuration

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STATELESS: started statelessly 

Explanation    Port-channel manager started with startup configuration

Recommended Action    No action is required.

EUREKA_USD Messages

This section contains the EUREKA_USD messages.

EUREKA_USD-3

Error Message    EUREKA_USD-3-MSG1: [chars] 

Explanation    Eureka log message

Recommended Action    No action is required.

EVMC Messages

This section contains the EVMC messages.

EVMC-5

Error Message    EVMC-5-AVL_CREATE_FAIL: [chars]([dec]): AVL Tree creation failure 

Explanation    Event Manager could not initialize local policy store

Recommended Action    No action is required.

Error Message     EVMC-5-MALLOC_FAILURE: [chars]([dec]): Memory allocation failure 

Explanation    Event Manager Client process could not allocate memory

Recommended Action    No action is required.

Error Message     EVMC-5-RT_PSS_OP_FAILURE: [chars]([dec]): Failed to [chars]. 
Error:[chars] 

Explanation    Event Manager Client could access HA store

Recommended Action    No action is required.

EVMS Messages

This section contains the EVMS messages.

EVMS-2

Error Message    EVMS-2-EVMS_PSS_DELETE_FAILURE: Delete from PSS failed 

Explanation    Delete from PSS failed

Recommended Action    No action is required.

Error Message     EVMS-2-EVMS_PSS_WRITE_FAILURE: Write to PSS failed 

Explanation    Write to PSS failed

Recommended Action    No action is required.

Error Message     EVMS-2-EVMS_SHOW_POLICY_ALLOC_FAILURE: Insufficient memory: policy 
information shown will be incomplete 

Explanation    Memory allocation failed. so complete requested information is not being shown

Recommended Action    No action is required.

EVMS-4

Error Message     EVMS-4-EVMS_APPLET_NO_ACTION_DEFAULT: WARNING: The default system 
policy actions are being skipped 

Explanation    The default system policy actions are being skipped

Recommended Action    No action is required.

EXCEPTIONLOG Messages

This section contains the EXCEPTIONLOG messages.

EXCEPTIONLOG-SLOT#-2

Error Message    EXCEPTIONLOG-SLOT#-2-LC_EXP_MSG: Linecard exception: [chars] is the 
affected Port bit map. [dec] Additional information - [chars] 

Explanation    LC Exception event.

Recommended Action    No action is required.

FC-TUNNEL Messages

This section contains the FC-TUNNEL messages.

FC-TUNNEL-3

Error Message    FC-TUNNEL-3-INTERNAL_ERROR: Internal error: [chars] 

Explanation    FCMPLS tunnel process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-IPFC_ERROR: IPFC API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked IPFC API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-MTS_ERROR: MTS message transmission failed with error 
[dec] 

Explanation    FCMPLS tunnel process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-NS_ERROR: FCNS API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PM_ERROR: Port Manager API, [chars], failed with error 
[hex] 

Explanation    FCMPLS tunnel invoked Port Manager API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for 
[chars] failed with error [hex] 

Explanation    FCMPLS tunnel read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system error code

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_ERROR: PSS operation [chars] returned error: [hex] 

Explanation    [chars] specifies the context where the failure occurred and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    FCMPLS tunnel read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-RIB_ERROR: RIB API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-RSVP_PROTO_ERROR: RSVP protocol error: [chars] 

Explanation    RSVP-TE protocol error is encountered. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], 
is received 

Explanation    FCMPLS tunnel process received unexpected MTS event. MTS opcode is specified in [dec]

Recommended Action    No action is required.

FC-TUNNEL-5

Error Message     FC-TUNNEL-5-MSG_INTERFACE_DOWN: Interface [chars] is down 

Explanation    The logical fc tunnel interface is down. This may be due to a reconfiguration on the fc tunnel, or issues on the underlying physical interface

Recommended Action    If this is not due to a known reconfiguration, you should verify connectivity at the physical port level, and then on then on the fc tunnel interface. Furthermore, verify the physical ports along the fc tunnel path operate in the TE mode

Error Message     FC-TUNNEL-5-MSG_INTERFACE_UP: Interface [chars] is up 

Explanation    The fc interface is up

Recommended Action    No action is required.

FCC_LC Messages

This section contains the FCC_LC messages.

FCC_LC-2

Error Message    FCC_LC-2-ERROR_SENDING_HEART_BEAT: Error sending heart beat [dec] 

Explanation    FCC_LC has error sending heart beat

Recommended Action    No action is required.

Error Message     FCC_LC-2-EXITING: Exiting fcc_lc: [chars] 

Explanation    FCC_LC exiting

Recommended Action    No action is required.

Error Message     FCC_LC-2-HEART_BEAT_NOT_SENT: Heart beat not sent for [dec] millisecs 

Explanation    FCC_LC has not sent heart beat

Recommended Action    No action is required.

Error Message     FCC_LC-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    FCC_LC Process is shutting down

Recommended Action    No action is required.

Error Message     FCC_LC-2-UNABLE_READ_DATA: Unable to read fcc data ([chars]) 

Explanation    FCC is unable to read and process relevant FCC data

Recommended Action    No action is required.

FCC_LC-5

Error Message     FCC_LC-5-BAD_MSG: Received bad message: [chars] 

Explanation    FCC_LC has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     FCC_LC-5-DISABLE: FCC_LC has been disabled 

Explanation    FCC_LC has been disabled

Recommended Action    No action is required.

Error Message     FCC_LC-5-ENABLE: FCC_LC has been enabled 

Explanation    FCC_LC has been enabled

Recommended Action    No action is required.

Error Message     FCC_LC-5-STARTING: FCC_LC process started 

Explanation    Process started successfully

Recommended Action    No action is required.

Error Message     FCC_LC-6-PRIO_UPDATE: Updated enable priority to [dec] 

Explanation    FCC_LC is active for packets with priority <= [threshold]

Recommended Action    No action is required.

Error Message     FCC-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    FCC Process is shutting down

Recommended Action    No action is required.

FCC-5

Error Message     FCC-5-BAD_MSG: Received bad message: [chars] 

Explanation    FCC has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     FCC-5-CONGESTION_STATE_CHANGE_NOTIF: Received Congestion State Change 
notification to state: [dec] 

Explanation    FCC has received a Contestion State Change Notification

Recommended Action    No action is required.

Error Message     FCC-5-DISABLE: FCC has been disabled 

Explanation    FCC has been disabled

Recommended Action    No action is required.

Error Message     FCC-5-ENABLE: FCC has been enabled 

Explanation    FCC has been enabled

Recommended Action    No action is required.

Error Message     FCC-5-RATE_LIMIT_END_NOTIF: Received Rate Limit End notification 

Explanation    FCC has received a Rate Limit End Notification

Recommended Action    No action is required.

Error Message     FCC-5-RATE_LIMIT_START_NOTIF: Received Rate Limit Start notification 

Explanation    FCC has received a Rate Limit Start Notification

Recommended Action    No action is required.

Error Message     FCC-5-STARTING: FCC process started 

Explanation    Process started successfully

Recommended Action    No action is required.

FCC-6

Error Message     FCC-6-PRIO_UPDATE: Updated enable priority to [dec] 

Explanation    FCC is active for packets with priority <= [threshold]

Recommended Action    No action is required.

FCDDH Messages

This section contains the FCDDH messages.

FCDDH-SLOT#-3

Error Message    FCDDH-SLOT#-3-LOG_FCDDH_ERR: Nonrecoverable error - exiting: [chars] 

Explanation    Errors which cause program to exit occurred

Recommended Action    No action is required.

FCDDH-SLOT#-4

Error Message     FCDDH-SLOT#-4-LOG_FCDDH_WARNING: Serious error: [chars] 

Explanation    Serious errors which affect all normal operations occurred

Recommended Action    No action is required.

FCDDH-SLOT#-5

Error Message     FCDDH-SLOT#-5-LOG_FCDDH_DEBUG: Unexpected error: [chars] 

Explanation    Unexpected errors which affect some normal operations occurred

Recommended Action    No action is required.

Error Message     FCDDH-SLOT#-5-LOG_FCDDH_NOTICE: [chars] 

Explanation    Major configuration changes

Recommended Action    No action is required.

FCDD Messages

This section contains the FCDD messages.

FCDD-SLOT#-3

Error Message    FCDD-SLOT#-3-LOG_FCDD_ERR: Nonrecoverable error - exiting: [chars] 

Explanation    Errors which cause program to exit occurred

Recommended Action    No action is required.

FCDD-SLOT#-4

Error Message     FCDD-SLOT#-4-LOG_FCDD_WARNING: Warning!: [chars] 

Explanation    Serious errors which affect all normal operations occurred

Recommended Action    No action is required.

FCDD-SLOT#-5

Error Message     FCDD-SLOT#-5-LOG_FCDD_GCONF_FSM: [chars] 

Explanation    Illegal event received in Global Configuration FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_NOTICE: [chars] 

Explanation    Major configuration changes

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_RESCAN_FSM: [chars] 

Explanation    Illegal event received in Rescan FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_TZONE_FSM: [chars] 

Explanation    Illegal event received in Twilight Zone Remover FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_VCONF_FSM: [chars] 

Explanation    Illegal event received in VSAN Configuration FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_VNO_FSM: [chars] 

Explanation    Illegal event received in VSAN Normal Operation FSM

Recommended Action    No action is required.

FCDD-SLOT#-7

Error Message     FCDD-SLOT#-7-LOG_FCDD_DEBUG: [chars] 

Explanation    Unexpected errors which affect some normal operations occurred

Recommended Action    No action is required.

FCDOMAIN Messages

This section contains the FCDOMAIN messages.

FCDOMAIN-2

Error Message    FCDOMAIN-2-DOMS_CONFLICT: Conflict detected: ([dec]) domain ID [dec] 
WWN [chars] 

Explanation    Conflict detected ([dec]) domain ID [dec] with WWN [chars].

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-EPORT_ISOLATED: Isolation of interface [chars] (reason: 
[chars]) 

Explanation    Fcdomain has isolated interface [chars] (reason: [chars].) Perform a show interface. Based on the reason specified, you might have to ensure domains are adequate and unique in the VSAN and perform a disruptive restart [fcdomain restart disruptive vsan <vsan-id>] or to reinitialize the port.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2BIND_FAILED: Bind to FC2 Service failed 

Explanation    Fcdomain has not been able to contact the FC2 module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2_INITIALIZATION_FAILED: FC initialization sequence 
failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the Fibre Channel subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2_SET_SOCKOPT_DM_SOCK_FAILED: set sockopt to FC2 Service 
failed 

Explanation    Fcdomain has not been able to setsockopt to the FC2 module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FCID_PERSISTENT_TBL_COMPLETELY_FULL: FCID persistent 
table is completely full 

Explanation    The FCID persistent table is full. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table. No more entries can be saved as persistent FCIDs across reboots.

Recommended Action    Purge stale entries [purge fcdomain fcid] to obtain more free entries OR disable the feature on certain VSANs which are not critical enough [no fcdomain fcid persistent].

Error Message     FCDOMAIN-2-HIGH_PRIORITY_MTSBIND_FAILED: Bind for high priority IPC 
failed 

Explanation    Fcdomain has not been able to contact the Inter Process Communication (IPC) module for its high priority queue.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-INITIALIZATION_FAILED: Initialization sequence failed 

Explanation    The fcdomain has not been able to complete the initialization sequence. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTSBIND_FAILED: Bind to IPC failed 

Explanation    Fcdomain has not been able to contact the Inter Process Communication (IPC) module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTSREGISTRATION_FAILED: Registration of opcodes with IPC 
Service failed 

Explanation    Fcdomain has not been able to register its messages with the Inter Process Communication (IPC) module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTS_INITIALIZATION_FAILED: IPC initialization sequence 
failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the IPC (Inter Process Communication) subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MY_NON_VIRTUAL_DOM_CONFLICTS: During VSAN merge detected 
that the local switch has the same domain ID [dec] and WWN [chars] of another 
switch 

Explanation    It has been detected that the local switch has the same domain ID [dec] and WWN [chars] of another switch.

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-NON_VIRTUAL_DOMS_CONFLICTS: During VSAN merge detected 
conflict between two switches having the same non-virtual domain ID [dec] and the 
same WWN [chars] 

Explanation    It has been detected that two switches have the same non-virtual domain ID [dec] and the same WWN [chars].

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-PSSBIND_FAILED: Bind to Persistent Storage Service failed 

Explanation    Fcdomain has not been able to contact the Persistent Storage Service (PSS).

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-RDIRJT: Rejected request for domain ID [dec], WWN requestor 
[chars] (reason code [dec]) 

Explanation    An invalid request for domain IDs has been rejected by fcdomain.

Recommended Action    Perform [show fcdomain vsan <vsan-id>] for all the switches in the affected VSAN; if a switch does not have a valid current domain ID, configure preferred domain ID zero, then perform [fcdomain restart vsan <vsan-id>] in the affected VSAN.

Error Message     FCDOMAIN-2-SYSBIND_FAILED: Bind to System Manager service failed 

Explanation    Fcdomain has not been able to contact the System Manager.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-SYSMGR_INITIALIZATION_FAILED: System Manager 
initialization sequence failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the System Manager. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

FCDOMAIN-3

Error Message     FCDOMAIN-3-COMMITERRORLOCALINVALIDALLOWEDDOMS: A remote switch 
attempted to locally apply an illicit allowed domains configuration 

Explanation    A remote switch attempted to locally apply an allowed domains configuration that doesn't include all currently assigned domains or the locally configured domain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-COMMITERRORREMOTEINVALIDALLOWEDDOMS: A remote switch 
(domain ID [dec], WWN [chars]) refuses to locally apply the proposed allowed 
domains 

Explanation    The remote switch with domain ID [dec] and WWN [chars] refuses to locally apply the proposed allowed domains probably due to incompatibility with its local configured domain or the domain ID list.

Recommended Action    Check the configuration on the remote switch, and make sure that the proposed allowed domains include it. Also, make sure that the the proposed allowed domains include all the domains in the domain ID list.

Error Message     FCDOMAIN-3-MTSOPENTRX_FAILED: IPC failure (opening of a transaction 
failed) 

Explanation    Fcdomain was not able to open a transaction( HA Purposes.)

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-MTSRECV_FAILED: IPC failure (receiving of a message 
failed) 

Explanation    Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-MTSRESP_FAILED: IPC failure replying to a request message 
(error [hex]) 

Explanation    Fcdomain has not been able to reply to a request coming from the Inter Process Communication (IPC) module (error [hex]).

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive).

Error Message     FCDOMAIN-3-MTSSENDREQ_FAILED: IPC failure (sending of a request 
failed) 

Explanation    Fcdomain was not able to send a request using the Inter Process Communication module.

Recommended Action    Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-MTSSEND_FAILED: IPC failure (sending of a message (syserr 
[hex], opc [dec], mtsq [dec], sap.node [hex], sap_addr [dec]) failed) 

Explanation    Fcdomain has not been able to send a message to the Message Transactional Service (MTS).

Recommended Action    Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive).

Error Message     FCDOMAIN-3-MTS_H_RECV_FAILED: IPC failure (receiving of a message 
failed) 

Explanation    Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-NVRAMFAILURE: NVRAM open failed 

Explanation    Reading the last assigned runtime domain IDs from Non Volatile RAM (NVRAM) failed.

Recommended Action    Fcdomain is able to continue without access to the Non Volatile RAM (NVRAM.)

Error Message     FCDOMAIN-3-PORT_SUSPENDED: Response (Cmd Code [hex]) for SWILS [hex] 
intended for [chars] is received on [chars] 

Explanation    An FC2 response frame (Command Code [hex]) for SWILS [hex] that was intended for interface [chars] has been received on [chars] instead.

Recommended Action    Check the configuration of both interfaces on the local switch and the interfaces on the other side of their corresponding links. In particular, check whether they should all belong to the same port-channel.

Error Message     FCDOMAIN-3-SDWRAPBIND_FAILED: Bind to debug server failed 

Explanation    Fcdomain feature has not been able to contact the debug service. Any problems occurring in the fcdomain feature will not be logged.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-SDWRAPHISTINIT_FAILED: Initialization of history message 
list failed. 

Explanation    Fcdomain feature has not been able to contact the debug history service. Any problems occurring in the fcdomain feature will not be logged to this debug history.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-VSAN_MERGE_DETECTED: Merge detected with VSAN [dec] 
(Common Fabric Name [chars]) 

Explanation    The local VSAN and VSAN [dec] have the same principal switch [chars], hence are connected in the same logical fabric.

Recommended Action    No action is required.

FCDOMAIN-4

Error Message     FCDOMAIN-4-DM_ALLOWED_DM_LIST_MOD_ON_SUBORDINATE: Allowed domain 
list for vsan [dec] modified on subordinate switch with fcdomain distribution 
enabled 

Explanation    When distribution is enabled, it is recommended to modify the allow domain list on the principal switch only.

Recommended Action    Abort the current session on the local switch and start a new one on the principal switch.

Error Message     FCDOMAIN-4-FABRICCONFSTARTRCF: Disruptive reconfiguration started 

Explanation    A disruptive reconfiguration (RCF phase) of the VSAN has started. This can happen when two or more fabrics merge disruptively, or when the user manually triggers a diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-4-FC2_CORRUPTED: Received malformed FC2 [chars] frame 

Explanation    Fcdomain received a malformed FC2-SWILS frame.

Recommended Action    No action is required.

Error Message     FCDOMAIN-4-FCID_PERSISTENT_TBL_ALMOST_FULL: FCID persistent table is 
almost full 

Explanation    Fcdomain has 80% or more of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.

Recommended Action    Purge stale entries [purge fcdomain fcid] to obtain more free entries.

FCDOMAIN-5

Error Message     FCDOMAIN-5-DOMAIN_TYPE_IS_PREFERRED: The domain ID type is currently 
configured as preferred in all the existing VSANs 

Explanation    All the currently existing VSANs have the domain ID type configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link.

Recommended Action    Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.

Error Message     FCDOMAIN-5-FCIDP_DISABLED: FCID persistency feature is currently not 
enabled in any of the existing VSANs 

Explanation    All the currently existing VSANs have the FCID persistency feature disabled.

Recommended Action    Type [fcdomain fcid persistent vsan <vsan-id>] to enable FCID persistency in an existing VSAN. Type [fcdomain fcid persistent global-enable] to automatically enable the FCID persistency feature on all newly created VSANs.

Error Message     FCDOMAIN-5-FCID_PERSISTENT_TBL_HALF_FULL: FCID persistent table is 
half full 

Explanation    Fcdomain has 50% of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.

Recommended Action    You may want to purge stale entries [purge fcdomain fcid] to obtain more free entries.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSDATAREQUEST: Received CFS Data request 
from unknown domain [dec]. 

Explanation    A CFS Data request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSLOCKREQUEST: Received CFS Lock request 
from unknown domain [dec]. 

Explanation    A CFS Lock request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSRELEASEREQUEST: Received CFS Release 
request from unknown domain [dec]. 

Explanation    A CFS Release request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININUNKNOWNCFSREQUEST: Received CFS request 
from unknown domain [dec]. 

Explanation    A CFS request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

FCDOMAIN-6

Error Message     FCDOMAIN-6-BF_STARTED: BF started by [chars] 

Explanation    Build Fabric has been started in this VSAN

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-CANNOTFREESINGLEFCID: Impossible to free single FCIDs 

Explanation    Impossible to free single FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-CLEARLOCKNOTIFICATIONRECEIVED: Implict lock release. 

Explanation    Lock has been implicitly released due to a clear session operation.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOMAINID_INVALID: Local domain ID invalid 

Explanation    The local domain ID is invalid.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOMAINID_VALID: Local domain ID [dec] available 

Explanation    The domain ID [dec] is available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOWNSTREAM_SWITCHED: Downstream interface has been 
fast-switched from [chars] to [chars] 

Explanation    Because of a link failure the downstream interface has been fast-switched from [dec] to [dec].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_ALREADY_CREATED: Interface [chars] already created 

Explanation    Interface [chars] already created.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_ALREADY_DOWN: Interface [chars] is already down 

Explanation    Interface [chars] already down.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_CLEANUP: Interface [chars] received cleanup request 

Explanation    Fcdomain on interface [chars] has received a cleanup request.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_CREATED: Creation of interface [chars] 

Explanation    Fcdomain is going to create interface [chars].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_DOWN: Interface [chars] is down 

Explanation    Fcdomain is going to remove interface [chars] from its database.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICCONFSTARTBF: Non disruptive reconfiguration started 

Explanation    A non disruptive reconfiguration (BF phase) of the VSAN has started. This can happen when two or more fabrics merge, or when the user manually triggers a non diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICNAME_INVALID: Fabric name not available 

Explanation    Fabric name not available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICNAME_VALID: Fabric name [chars] available 

Explanation    Fabric name [chars] available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDALREADYFREE: FCIDs already free 

Explanation    FCIDs already free.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDNOTSTORED: FCIDs not stored 

Explanation    FCIDs not stored.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDP_ENABLED_DOM_TYPE_PREFERRED: FCID persistency is 
enabled, but the domain ID type is configured as preferred 

Explanation    The FCID persistency feature is enabled, but the domain ID type is configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link. Should the domain ID change, all the FCIDs associated with it would be invalidated.

Recommended Action    Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.

Error Message     FCDOMAIN-6-FCIDS_ASSIGNED: Assigned a sequence of 256 contiguous 
FCIDs starting from FCID [hex]:[hex]:[hex] 

Explanation    Assigned a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDS_FREED: Freed a sequence of 256 contiguous FCIDs 
starting from FCID [hex]:[hex]:[hex] 

Explanation    Freed a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCID_ASSIGNED: Assigned single FCID [hex]:[hex]:[hex] 

Explanation    Assigned single FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCID_FREED: Freed single FCID [hex]:[hex]:[hex] 

Explanation    Freed single FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INCORRECTDOMAINRANGE: Requested FCIDs with domain field 
not in expected range 

Explanation    Requested FCIDs with domain field not in expected range.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INCORRECTDOMAIN: Requested FCIDs with domain field 
different from local domain 

Explanation    Requested FCIDs with domain field different from local domain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INVALIDARG: Requested FCID of type 00.00.YY, but 
specifying an entire area 

Explanation    Requested FCID of type 00.00.YY, but specifying an entire area.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-MY_SAME_WWN_DIFFERENT_DOMS_CONFLICTS: During VSAN merge 
detected local WWN [chars] is already in use by another switch (the two switches 
have different domain IDs: [dec] (local) and [dec]) 

Explanation    It has been detected that the local switch has the same WWN [chars] of another switch, and that they have different domain IDs: [dec] (local) and [dec].

Recommended Action    Check which switches have the same WWN and change either one.

Error Message     FCDOMAIN-6-NODOMAIN: Local domain not available 

Explanation    The local domain is not available yet.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-NOFREEFCID: No free FCIDs 

Explanation    No free FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-NOTOWNER: Feature [dec] cannot free FCID [dec]:[dec]:[dec] 
(feature [dec] is the actual owner) 

Explanation    Feature UUID [dec] cannot free FCID [dec]:[dec]:[dec] because it is not its owner (UUID actual owner is [dec]).

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-OTHER_SIDE_VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN 
merge detected overlap with virtual IVR domain ID [dec] from across the link 

Explanation    It has been detected an overlap with the virtual IVR domain ID [dec] from across the link during an attempt to merge the local VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-PSWSSTARTED: Principal Switch Selection started 

Explanation    Fcdomain started a principal switch selection phase to elect a principal switch in this VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-RCF_STARTED: RCF started by [chars] 

Explanation    Reconfigure Fabric has been started in this VSAN

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQSINGLEFCIDWITHINRESERVEDRANGE: Requested single FCIDs 
in area [dec] within the reserved range 

Explanation    Requested single FCIDs in area [dec] within the reserved range.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDFCIDNOTFREE: Requested FCIDs not free 

Explanation    Requested FCIDs not free.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDFCIDRESERVED: Requested reserved FCIDs 

Explanation    Requested reserved FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDRESERVEDFCIDMISMATCH: Requested persistent 
FCIDs, but there is a mismatch 

Explanation    Requested persistent FCIDs, but there is a mismatch.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-SAME_WWNS_DIFFERENT_DOMS_CONFLICTS: During VSAN merge 
detected two switches with same WWN [chars] and different non-virtual domain IDs 
[dec] and [dec] 

Explanation    It has been detected that two switches have the same WWN [chars], but different non-virtual domain IDs: [dec] and [dec].

Recommended Action    Check which switches have the same WWN and change either one.

Error Message     FCDOMAIN-6-TIMER_UNKNOWN: fcdomain has received a notification for an 
unknown timer expiration

Explanation    A timer unknown to fcdomain has expired.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UPSTREAM_SWITCHED: Upstream interface has been 
fast-switched from [chars] to [chars] 

Explanation    Because of a link failure the upstream interface has been fast-switched from [dec] to [dec].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UUIDNOSPACEFOUND: No available space to store the identity 
of the requestor the FCIDs 

Explanation    No available space to store the identity of the requestor the FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UUIDNOTFOUND: Universal Unique ID (UUID) not found 

Explanation    Universal Unique ID (UUID) not found.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN merge detected 
overlap with local virtual IVR domain ID [dec] 

Explanation    It has been detected an overlap with the local virtual IVR domain ID [dec] during an attempt to merge the local VSAN.

Recommended Action    No action is required

FCDOMAIN-7

Error Message     FCDOMAIN-7-EPORT_ALREADY_ISOLATED: Interface [chars] is already 
isolated or down 

Explanation    Fcdomain was going to isolate interface [chars], but the interface is already isolated.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FABRICCONFCOMPLETEDBF: Non disruptive reconfiguration 
completed 

Explanation    A non disruptive reconfiguration (BF phase) completed. This can happen when two or more fabrics merged, or when the user manually triggered a non diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FABRICCONFCOMPLETEDRCF: Disruptive reconfiguration 
completed 

Explanation    A disruptive reconfiguration (RCF phase) of the VSAN has completed. This can happen when two or more fabrics merged disruptively, or when the user manually triggered a diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FC2_RETRY: Retransmission of FC2 frame on interface 
[chars] (Cmd Code: [hex]) 

Explanation    Fcdomain is retrying an FC2 frame on interface [chars] due to loss/no response. The Command Code of the frame is [hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FCID_IN_USE_PURGING_FOR_FICON_MGR: FICON needs to purge 
the persistent FCID table, but at least one FCID is still in use, preventing this 
purge from completely remove all entries belonging to the VSAN.

Explanation    There may be a problem in the sequence that shuts down all interfaces before fcdomain receives a request from FICON Manager to purge the persistent FCID table.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FSM_FAILED: FSM transition failed on interface [chars] 
(current state [chars]) 

Explanation    Fcdomain state machine generated an invalid event on interface [chars], for which no proper action was defined (current state [chars].)

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FSM_FORBIDDEN_TRANSITION: fcdomain state machine has hit 
a forbidden transition 

Explanation    Fcdomain state machine has tried to execute a forbidden transition.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-INTERFACERDY: Interface [chars] ready 

Explanation    Interface [chars] is ready.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-PREACTIONTYPE_UNKNOWN: fcdomain state machine has hit an 
unknown pre-action type 

Explanation    An undefined pre-action type has been used.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-PSWSCOMPLETED: Principal Switch Selection completed 

Explanation    A Principal Switch Selection (PSwS phase) completed.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-RDIACC: Assigned domain ID [dec], WWN of requestor [chars] 
(requested domain ID [dec]) 

Explanation    Domain ID [dec] has been received by VSAN with WWN [chars] (requested domain ID was [dec].)

Recommended Action    No action is required.

Error Message     FCD-7-SB3_ABTS_EXCHANGE: sb3 aborted exchange [hex] from vsan:[dec] 
ch:[hex] chi:[hex] ccw:[hex] token:[hex] cmd:[hex] reason:[chars] 
state:[chars]:[dec] 

Explanation    SB3 aborted exchange due to reason given. Aborts are caused by either the channel or control unit detecting a device protocol error. Recovery actions are performed to restore communication. In certain circumstances aborts occur in normal operations.

Recommended Action    No action is required if communication with CUP device is still operational.

Error Message     FCD-7-SB3_UCS_PER_FILE_FN: VSAN:[dec] Unit Check for perform file 
function, reason: [chars] 

Explanation    SB3 failed perform file function. Failure is caused by error in the file main frame sent to director.

Recommended Action    No action is required if communication with CUP device is still operational.

FCFWD Messages

This section contains the FCFWD messages.

FCFWD-3

Error Message    FCFWD-3-ERROR: [chars] 

Explanation    Fcfwd encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FCFWD-4

Error Message     FCFWD-4-WARNING: [chars] 

Explanation    Fcfwd is generating a relevant notification

No action is required.

Error Message    FCFWD-6
Error Message     FCFWD-6-INFO: [chars] 

Explanation    An fcfwd event occurred

Recommended Action    No action is required.

FCNS Messages

This section contains the FCNS messages.

FCNS-2

Error Message    FCNS-2-DB_FULL: the database; max entries [dec] exceeded 

Explanation    Name server database is full. The max number of entries, [dec], of ports is already present in the database

Recommended Action    No action is required.

Error Message     FCNS-2-INIT_FAILURE: : [chars] 

Explanation    Fcns initialisation has failed due to [chars].

Recommended Action    No action is required.

Error Message     FCNS-2-NO_RESPONSE: for query [chars] from domain [dec] 

Explanation    No response for query [chars] from domain [dec].

Recommended Action    No action is required.

Error Message     FCNS-2-PSS_VERSION_MISMATCH: : for [chars] 

Explanation    Version mismatch for pss of type [chars].

Recommended Action    No action is required.

Error Message     FCNS-2-RELOAD_FAILURE: : [chars] 

Explanation    Failed to reload information from PSS: [chars].

Recommended Action    No action is required.

FCNS-3

Error Message     FCNS-3-BAD_FRAME: : [chars] 

Explanation    Received a bad frame from the network: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-CFG_FAILURE: : [chars] 

Explanation    A failure related to fcns configuration: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-CHUNK_FAILURE: : [chars] 

Explanation    Chunk memory failure: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-DB_FAILURE: : [chars] 

Explanation    A failure occured in fcns database: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-MALLOC_FAILURE: : [chars] 

Explanation    Malloc failed: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-MTS_FAILURE: : [chars] [chars] 

Explanation    Failure occured trying to do an MTS operation: [chars] [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-PSS_FAILURE: : [chars] 

Explanation    Pss failure: [chars].

Recommended Action    No action is required.

FCNS-4

Error Message     FCNS-4-QUERY_NO_RESPONSE: for query [chars] from domain [dec] 

Explanation    No response for query [chars] from domain [dec].

Recommended Action    No action is required.

FCNS-6

Error Message     FCNS-6-DB_INFO: : [chars] [hex] 

Explanation    Database modification:[chars] for entry [hex].

Recommended Action    No action is required.

Error Message     FCNS-6-STATUS_INFO: : [chars] 

Explanation    A change in fcns status: [chars].

Recommended Action    No action is required.

FCSP-MGR Messages

This section contains the FCSP-MGR messages.

FCSP-MGR-2

Error Message    FCSP-MGR-2-DBG_INIT_FAILED: Debug Infrastructure Initialization 
failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an 
E_Port failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the FC-2 E-Port infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an 
F_Port failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the FC-2 F-Port infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown 
FC-2 frame on [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FCSP_AUTHENT_FAILURE: FC-SP Authentication failure on Port 
[chars] (FC-SP Failure Reason: [chars] [chars]) 

Explanation    Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FCSP_ESP_MISMATCH: ESP parameters mismatch failure on Port 
[chars] (reason:[chars]) 

Explanation    Fibre-Channel ESP parameters mismatch with the peer on Port [chars].(Reason: [chars]). Please check ESP configurations on both side of the link and ensure appropriate ESP mode on this port as well as peer port

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FSMU_INIT_FAILED: State Machine Infrastructure 
Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-IPC_INIT_FAILED: IPC (Inter Process Communication) 
Initialization failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the IPC infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service 
exiting 

Explanation    License of [chars] is unavailable. Service will exit now

Recommended Action    Please install the license file to continue using the feature.

Error Message     FCSP-MGR-2-MEM_FAILED: Memory operations failed File: [chars] Line 
[dec] for size [hex] bytes 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-POST_INIT_FAILED: Post-Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed 
( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

FCS Messages

This section contains the FCS messages.

FCS-2

Error Message    FCS-2-ALLOC_FAILED: Memory allocation failed for size:[dec] 

Explanation    Memory allocation failed for size [dec]

Recommended Action    Restart the process

Error Message     FCS-2-CHUNK_ALLOC_FAILED: Chunk memory allocation failed for [chars] 
chunk 

Explanation    Chunk memory allocation failed. [chars] indicates the chunk name

Recommended Action    Restart the process

Error Message     FCS-2-NO_RESPONSE: Retried maximum number of times for [chars] to 
domain [dec] in VSAN [dec] 

Explanation    Maximum number of retires completed for [chars] form domain [dec] in VSAN [dec].

Recommended Action    No action is required.

Error Message     FCS-2-PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], 
expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-2-RANDNUM_FAIL: [chars] 

Explanation    There was a critical error during random number generation. [chars] indicates details of the error

Recommended Action    No action is required.

FCS-3

Error Message     FCS-3-DB_ERR: [chars] 

Explanation    An error occurred during an FCS database operation. [chars] indicates the reason for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-INIT_FAIL: [chars] 

Explanation    An error happened during FCS Initialization. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-MTS_ERR: [chars] 

Explanation    An error occurred in processing of an MTS message. [chars] indicates the error that occurred

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-NO_MTS_RESP: [chars] 

Explanation    There was no response to an MTS request. [chars] indicates details of the MTS message

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-NO_REMOTE_RESP: No response for request [chars] from domain 
[dec] in VSAN [dec] 

Explanation    There was no response to an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-OTHER_ERR: [chars] 

Explanation    An FCS generic error occurred. [chars] indicates the description of the error

Recommended Action    No action is required.

Error Message     FCS-3-PSS_ERR: [chars] 

Explanation    An error occurred during an FCS PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-SOCK_ERR: sd: [dec], [chars] 

Explanation    An FC-2 Socket error occurred on socket-ID [dec]. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FCS-4

Error Message     FCS-4-BAD_CT_FRAME: Invalid FCS frame: [chars] received from [hex] 

Explanation    An invalid FCS FC-CT frame with [chars] received from FC-ID [hex].

Recommended Action    No action is required.

FCS-5

Error Message     FCS-5-API_FAIL: [chars]: [chars] 

Explanation    An API called by FCS failed. [chars] indicates the API name failed and [chars] the reason for failure

Recommended Action    If this message is seen during a cold boot, it means that the queried module came up after FCS and this case can be ignored

Error Message     FCS-5-DB_NOTICE: [chars] 

Explanation    An error occurred during an FCS database operation. [chars] indicates the reason for the error

Recommended Action    No action is required.

FCS-6

Error Message     FCS-6-INFORMATION: [chars] 

Explanation    An event happend that affects FCS. [chars] indicates the event

Recommended Action    No action is required.

Error Message     FCS-6-REXMIT_PKT: Retransmitting request [chars] to domain [dec] in 
VSAN [dec] 

Explanation    There was a retransmission of an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID

Recommended Action    No action is required.

FDMI Messages

This section contains the FDMI messages.

FDMI-2

Error Message    FDMI-2-MTS_ERROR: MTS message transmission failed with error [dec] 

Explanation    Fdmi process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]

Recommended Action    No action is required.

Error Message     FDMI-2-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] 
failed with error [hex] for key type [dec]

Explanation    Fdmi read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code

Recommended Action    No action is required.

Error Message     FDMI-2-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    Fdmi read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system err code

Recommended Action    No action is required.

FDMI-3

Error Message     FDMI-3-BAD_FRAME: Malformed frame received: [chars] 

Explanation    Fdmi process received malformed frame. [chars] describes the malformation

Recommended Action    No action is required.

Error Message     FDMI-3-BAD_RESPONSE: response with command code: [hex] 

Explanation    Fdmi process received bad payload in response

Recommended Action    No action is required.

Error Message     FDMI-3-INTERNAL_ERROR: Internal err: [chars] 

Explanation    Fdmi process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FDMI-3-MTS_API_ERROR: API, [chars] returned [hex] 

Explanation    Fdmi invoked API [chars], received the error code specified in 0x[hex]

Recommended Action    No action is required.

Error Message     FDMI-3-MTS_FORMAT_ERROR: Unknown MTS message format in opcode [dec] 
from module [chars] 

Explanation    Fdmi received message from module [chars] which contains unknown message format. MTS opcode is specified in [dec]

Recommended Action    No action is required.

Error Message     FDMI-3-NO_RESPONSE: No response from switch whose domain id is [dec] 

Explanation    Fdmi process sents a inter-switch packets to switches and has not received the response

Recommended Action    No action is required.

Error Message     FDMI-3-PSS_ERROR: PSS operation [chars] returned err: [hex] 

Explanation    [chars] specifies the context where the failure occured and 0x[hex] specifies the err

Recommended Action    No action is required.

Error Message     FDMI-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is 
received 

Explanation    Fdmi process received unexpected MTS event. MTS opcode is specified in [dec]

Recommended Action    No action is required.

FDMI-4

Error Message     FDMI-4-SW_REJ_RESPONSE: Reject response [chars] from switch whose 
domain id is [dec] 

Explanation    Fdmi process sents a inter-switch packets to switches and has received the reject response with reason code in [chars]

Recommended Action    No action is required.

FDMI-6

Error Message     FDMI-6-DEBUG_INFO: [chars] 

Explanation    Fdmi process debug info

Recommended Action    No action is required.

FEATURE-MGR Messages

This section contains the FEATURE-MGR messages.

FEATURE-MGR-2

Error Message    FEATURE-MGR-2-MODULE_FM_DONE: feature manager completed 

Explanation    Feature manager completed

Recommended Action    No action is required.

Error Message     FEATURE-MGR-2-MODULE_FM_STARTED: feature manager started 

Explanation    Feature manager started

Recommended Action    No action is required.

FICON Messages

This section contains the FICON messages.

FICON-2

Error Message    FICON-2-E_DUPLICATE_PN_BRINGUP_FAIL: [chars] 

Explanation    This port has the same port number assigned to other port in the same FICON VSAN. No more than one port with duplicate port number can be up in each FICON VSAN

Recommended Action    Avoid duplicate number assignment in each FICON VSAN\n

Error Message     FICON-2-E_PN_PA_NOT_IN_BOUND: [chars] 

Explanation    Port number or port address in startup-configure is out of bound.

Recommended Action    Change ficon port number assign configuration and save to startup-configure.\n

Error Message     FICON-2-E_SAVE_FILE: [chars] 

Explanation    Failed to save file. Possibly due to asymmetric pdcm matrix. Look for retval for actual reason.

Recommended Action    Configure port prohibits in symmetrically.\n

Error Message     FICON-2-SHUTDOWN: FICON Manager process shutting down: [chars] 

Explanation    FICON Manager shutting down

Recommended Action    This is a severe error. Provide the reason given in the message\n

FICON-3

Error Message     FICON-3-E_ASSIGN_BINDING_PN_FAIL: [chars] 

Explanation    Port number has fcip or port channle binding can not be removed nor changed.

Recommended Action    Remove port number binding of the logical interface first.\n

Error Message     FICON-3-E_ASSIGN_INVALID_PN_PARAM: [chars] 

Explanation    Invalid port number parameters in command.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_ASSIGN_OVERLAP_PN_FAIL: [chars] 

Explanation    Port number assigned to physical and logical can not overlap.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_ASSIGN_PN_NOT_DOWN_FAIL: [chars] 

Explanation    Only port number assigned to a port in down state can be removed or changed.

Recommended Action    Bring down the port first.\n

Error Message     FICON-3-E_ASSIGN_PROHIBIT_PN_FAIL: [chars] 

Explanation    Logical port address can not be prohibited.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_DUPLICATE_PN_ASSIGN_WARNING: [chars] 

Explanation    This port has the same port number assigned to other port in the same FICON VSAN. No more than one port should have the same port number in each FICON VSAN

Recommended Action    Avoid duplicate number assignment in each FICON VSAN\n

Error Message     FICON-3-E_INVALID_PA_BRINGUP_FAIL: [chars] 

Explanation    This port either has an invalid port address assigned or has no port address assigned.

Recommended Action    Assign a valid ficon port number to the port.\n

Error Message     FICON-3-E_PORT_PROHIBIT_BRINGUP_FAIL: [chars] 

Explanation    This port has been prohibited. Prohibiting E or TE ports is not allowed. This port can not be configured in E mode or TE mode until the prohibit mask configuration is changed

Recommended Action    Correct the prohibit mask (PDCM) for this port if you wish to bring it up as an E or TE port in a FICON VSAN\n

Error Message     FICON-3-E_UNASSIGN_NO_PN_FAIL: [chars] 

Explanation    Only port number already assigned can be removed.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-PDCM_CHANGE_REJ_E_PORT: [chars] 

Explanation    The FICON Prohibit Dynamic Connectivity Mask(PDCM) change rejected because an E or TE port is being prohibited. Prohibiting an E or TE port in not allowed

Recommended Action    Correct the prohibit mask (PDCM) for this port if you wish to bring the port up as an E or TE port in a FICON VSAN\n

FICON-5

Error Message     FICON-5-STARTING: FICON Manager process starting 

Explanation    FICON Manager process is being started

Recommended Action    No action is required.

FICON-6

Error Message     FICON-6-PDCM_CHANGE: VSAN [dec] port-address [dec] prohibit mask set 
to [chars] 

Explanation    The FICON Prohibit Dynamic Connectivity Mask (PDCM) for this port has changed. VSAN [dec], port address [dec] prohibit mask (PDCM) is now set to [chars]

Recommended Action    No action is required.

Error Message     FICON-6-PORT_SWAP: port number [dec] [dec] swapped 

Explanation    FICON portnumbers swapped

Recommended Action    No action is required.

Error Message     FICON-6-VSAN_DISABLED: FICON disabled on VSAN [dec] 

Explanation    FICON has been disabled on the given VSAN

Recommended Action    No action is required.

Error Message     FICON-6-VSAN_ENABLED: FICON enabled on VSAN [dec] 

Explanation    FICON has been enabled on the given VSAN

Recommended Action    No action is required.

FLOGI Messages

This section contains the FLOGI messages.

FLOGI-1

Error Message    FLOGI-1-MSG_FDISC_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface 
[chars]] FDISC rejected - this interface has reached the max num of N-Ports ([dec]) 

Explanation    An FDISC was rejected because the F-Port has reached the maximum allowed number of devices.

Recommended Action    Check the configuration of the NPIV device connected to the port.

Error Message     FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: [VSAN [dec], Interface [chars]] 
FLOGI rejected - FCID allocation failed. 

Explanation    An FLOGI was rejected because the FCID allocation failed.

Recommended Action    Check the fcid-interop configuration, purge the persistency table and check the output of show flogi database details and see if any of the A area FCID allocation entries can be turned to single fcid allocation as per Configuration Guide

Error Message     FLOGI-1-MSG_FLOGI_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface 
[chars]] FLOGI rejected - this interface has reached the max num of NL-Ports 
([dec]) 

Explanation    An FLOGI was rejected because the FL-Port has reached the maximum allowed number of devices.

Recommended Action    Reduce the number of devices on the loop

Error Message     FLOGI-1-MSG_NPIV_NOT_SUPPORTED_WITH_TRUNKING: [VSAN [dec], Interface 
[chars]] NPIV not supported - on this platform, NPIV is not supported on trunking 
interfaces 

Explanation    The N_Port requested NPIV, but this platform does not support NPIV on trunking F_Ports.

Recommended Action    Disable NPIV, or move the N_Port to a switch that supports NPIV on trunking F_Ports

FLOGI-2

Error Message     FLOGI-2-MSG_FLOGI_REJECT_NO_ACL_TCAM_AVAILABLE: [VSAN [dec], 
Interface [chars]] FLOGI rejected - ACLTCAM resource exausted 

Explanation    An FLOGI was rejected because the ACLTCAM hardware resource is completely used.

Recommended Action    Reduce the number of nodes.

FLOGI-4

Error Message     FLOGI-4-MSG_VF_FLOGI_FROM_NON_CISCO_OUI: [VSAN [dec], Interface 
[chars]] FLOGI with VF bit set from OUI [hex]:[hex]:[hex] (nwwn: [chars]) 

Explanation    This interface received an FLOGI with VF bit set from a non CISCO OUI; in this release Virtual Fabrics are not supported on interfaces connected to third-party devices

Recommended Action    Set the trunk mode of this interface to off

FLOGI-5

Error Message     FLOGI-5-MSG_FLOGI_DROP_DUE_TO_SUSPENDED_VSAN: [VSAN [dec], Interface 
[chars]] FLOGI (pwwn: [chars]) has been dropped because the VSAN is suspended on 
this trunking interface 

Explanation    The switch received an FLOGI from a trunking interface on a VSAN which has been suspended; the FLOGI frame has been dropped.

Recommended Action    To bring up the VSAN again on the trunking port, remove it from the allowed VSAN list and add it again

Error Message     FLOGI-5-MSG_IF_REINIT_ALPA_CONFLICT: [VSAN [dec], Interface [chars]] 
FL/TL interface [chars] re-initialized as ALPA - PWWN map conflict occurred. 

Explanation    The FL/TL interface is re-initialized as ALPA used by device conflicts with an existing FLOGI session after the Loop Initialization Protocol (LIP). All the devices will re-login with new ALPA and PWWN mapping

Recommended Action    No action is required.

Error Message     FLOGI-5-MSG_PORT_LOGGED_IN: [VSAN [dec], Interface [chars]] Nx Port 
[chars] with FCID [chars] logged IN. 

Explanation    Nx port logged in with the specified information.

Recommended Action    No action is required.

Error Message     FLOGI-5-MSG_PORT_LOGGED_OUT: [VSAN [dec], Interface [chars]] Nx Port 
[chars] logged OUT. 

Explanation    Nx port logged out. The following commands will help determine why this Nx port logged out: 'show interface, show VSAN, show module'

Recommended Action    No action is required.

FS-DAEMON Messages

This section contains the FS-DAEMON messages.

FS-DAEMON-2

Error Message    FS-DAEMON-2-FSD_ENOSPC_BOOTFLASH: Due to insufficient space, [chars] 
image could not be copied to standby bootflash. [chars] image is not present on 
standby. Please copy \[chars]\'manually.'

Explanation    Move system images from RAM to bootflash to free up some memory

Recommended Action    Please remove some unnecessary files on bootflash using \delete\'CLIcommandandcopyimagesfromactivesupervisororfromremotelocation'

FS-DAEMON-6

Error Message     FS-DAEMON-6-FSD_ENOSPC_LOGFLASH: System logflash usage has reached 
[dec]%. You may delete some old files on logflash to free up space 

Explanation    System logflash space is almost full

Recommended Action    Use 'clear core archived' or 'delete' CLI to free up space on logflash

Error Message     FS-DAEMON-6-FSD_ENOSPC_ROOT: System root usage has reached [dec]%. 
You may delete some old files from root or /var/log to free up space 

Explanation    System root space is almost full

Recommended Action    Use 'clear core archived' or 'delete' CLI to free up space on root dir or /var/log

Error Message     FS-DAEMON-6-FSD_ENOSPC_TMP: System temporary directory usage has 
reached [dec]%. 

Explanation    System /tmp space usage.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FSCM Messages

This section contains the FSCM messages.

FSCM-2

Error Message    FSCM-2-FABRIC_START_CFG_MGR_PROGRAM_EXIT: Fabric Start Cfg Mgr daemon 
exiting: [chars] 

Explanation    FABRIC_START_CFG_MGR daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FSPF Messages

This section contains the FSPF messages.

FSPF-2

Error Message    FSPF-2-SHUTDOWN: Routing daemon shutting down : [chars] 

Explanation    FSPF routing daemon is shutting down because of [chars] reason.

Recommended Action    This is a severe bug. Provide the reason provided and the log files for FSPF.

FSPF-3

Error Message     FSPF-3-BAD_FC2_PKT: Received bad FC2 packet on interface [chars] : 
[chars] 

Explanation    FSPF received a bad FC2 packet on [chars] interface , error description is [chars].

Recommended Action    FSPF daemon has received a bad FC frame. Provide the output of 'debug fc2 pkt '.

Error Message     FSPF-3-CHECKSUM_FAIL: Checksum test failed for LSR domain [dec] 

Explanation    Periodic database checksum test failed for LSR for domain [dec]

Recommended Action    This indicates that the internal database got corrupted because of some memory corruption bug. Provide output of 'show fspf database '. May need to power cycle the switch

Error Message     FSPF-3-FC2_PROC_ERR: Error in processing [chars] packet on interface 
[chars], Error = [chars] 

Explanation    An error occurred in processing a [chars] FC2 packet on [chars] interface. The internal error code is [chars].

Recommended Action    Turn on 'debug fspf error' to get more information. Make sure there is no misconfiguration of FSPF parameters on the two ends of the interface. Provide output of 'show fspf vsan x' 'show fspf vsan x interface' and 'debug fspf fc pkt ' for the specific interface

Error Message     FSPF-3-FLOOD_ERR: Error in flooding the local LSR , Error = [chars] 

Explanation    FSPF had an error in flooding the local LSR , error description is [chars].

Recommended Action    Provide output of 'debug fspf flood' , 'debug fspf error'. If error is reported in transmitting packet check if interface is up and turn on 'debug fc2 error'

Error Message     FSPF-3-HELLO_MISMATCH: Mismatch in [chars] in the Hello packet on 
interface [chars] 

Explanation    There is a mismatch in the [chars] entry in the hello packet received on interface [chars]. The packet will be dropped.

Recommended Action    Check the configuration of hello or dead interval on the switches on the two ends of the interface to see if there is a mismatch.

Error Message     FSPF-3-INTF_TIMER_ERR: Error in processing interface timer event 
[chars] for interface [chars] , error = [chars] 

Explanation    FSPF had an error in processing timer event for interface chars, error is [chars].

Recommended Action    Provide output of 'debug fspf error'

Error Message     FSPF-3-IPC_PROC_ERR: Error in processing IPC message : Opcode = [dec], 
Error code = [hex] 

Explanation    FSPF had an error in processing message of [dec] opcode , the internal error code is [dec].

Recommended Action    Possibly some wrong IPC message is received by FSPF . Provide output of 'debug fspf mts pkt' and 'debug fspf error ' trace.

Error Message     FSPF-3-LOCK_FAIL: FSPF failure in gaining lock 

Explanation    There is a software failure in gaining lock of the shared resource between FSPF threads.

Recommended Action    Provide output of 'debug fspf all '

Error Message     FSPF-3-MTS_MSG_BEFORE_GSYNC: FSPF in standby received MTS message 
opcode = [hex] before GSYNC 

Explanation    FSPF in standby received an MTS message of opcode [dec] before receiving the GSYNC message.

Recommended Action    Provide output of 'debug fspf mts pkt '

Error Message     FSPF-3-RIB_ERR: Error in RIB : [chars] 

Explanation    FSPF had an error in interacting with RIB, error description is [chars].

Recommended Action    Check if rib application is running using 'show processes'. Provide output of 'debug fspf route' and RIB debug traces.

Error Message     FSPF-3-ROUTE_COMPUTE_ERR: Error in computing or sending routes : Error 
= [chars] 

Explanation    FSPF had an error in computing routes , error description is [chars].

Recommended Action    Provide the error code and output of 'debug fspf error' and 'debug fspf route' if problem is reproducible

Error Message     FSPF-3-UNLOCK_FAIL: FSPF failure in releasing lock 

Explanation    There is a software failure in releasing lock of the shared resource between FSPF threads.

Recommended Action    Provide output of 'debug fspf all '

Error Message     FSPF-3-VSAN_TIMER_ERR: Error in processing VSAN timer event [chars], 
error description = [chars] 

Explanation    FSPF had an internal error in processing timer event , error description is [chars].

Recommended Action    Provide output of 'debug fspf error'

FSPF-4

Error Message     FSPF-4-FC2_DOWN_INTF: Received FC2 packet on DOWN interface [chars] 

Explanation    FSPF received a FC2 packet on inactive interface [chars] .

Recommended Action    This message may be printed for the first FSPF packet when an interface is brought up. If the message is seen continuously check if FSPF is disabled on one end for the interface or the VSAN. Otherwise check 'show interface ' output to see if interface is physically up only on one side. Also check if there is any error message printed for IPC_PROC_ERR

Error Message     FSPF-4-FC2_DOWN_VSAN: Received FC2 packet on inactive vsan 

Explanation    FSPF received a FC2 packet on inactive vsan.

Recommended Action    If message seen continuously check if FSPF is disabled on the VSAN Investigate if VSAN is active and valid domain has been assigned on the switch Also check if IPC_PROC_ERR message is printed in the syslog

Error Message     FSPF-4-ILLEGAL_FSM_EVENT: Illegal FSM event for state [chars] in 
interface [chars] 

Explanation    An illegal protocol event has occurred for the FSPF state machine. The old state was [chars] for the interface [chars].

Recommended Action    It is possible to get this message if some protocol packet gets dropped but the it should recover and move back to FULL state. Do 'show fspf interface' to check the state of the interface. If it is stuck in state other than FULL provide output of 'debug fspf event' and 'debug fspf fc pkt ' for the interfaces involved.

Error Message     FSPF-4-LSR_DROPPED: [chars], Dropping LSR [dec] received on interface 
[chars] 

Explanation    A LSR packet is dropped due to [chars] reason. LSR belonged to domain [dec] and was received on interface [chars].

Recommended Action    Provide the reason given for dropping the LSR and output of 'debug fspf fc pkt' If the reason is checksum failure investigate possible packet corruption or truncation

Error Message     FSPF-4-LSR_MIN_LS_ARRIVAL: Packet arrived before MIN_LS_ARRIVAL, 
Dropping LSR [dec] on interface [chars] 

Explanation    A LSR packet is dropped as it arrived before MIN_LS_ARRIVAL. LSR belonged to domain [dec] and was received on interface [chars].

Recommended Action    This can occur in transient situation and protocol recovers by retransmitting the LSR. If the message is seen continuously provide output of 'debug fspf flood ' , 'debug fspf retrans' and 'debug fspf error '. The message may be seen more often when interoperating with other vendors

Error Message     FSPF-4-LSU_RX_INIT: Dropping LSU received in state INIT on interface 
[chars] 

Explanation    A LSU packet is dropped as interface [char] is in INIT state when it received the LSU.

Recommended Action    This can occur in some transient situation. If the problem persists provide output of 'show fspf vsan x interface' and 'debug fspf fc pkt ' and 'debug fspf event vsan x'

FSPF-5

Error Message     FSPF-5-STARTING: Routing daemon started 

Explanation    FSPF routing daemon has been started.

Recommended Action    No action is required.

FSPF-6

Error Message     FSPF-6-ADD_LSR: New LSR added for domain [dec] 

Explanation    A new LSR is added to the database for domain [dec] .

Recommended Action    No action is required.

Error Message     FSPF-6-DELETE_LSR: LSR deleted for domain [dec] 

Explanation    The LSR for domain [dec] is deleted from the database.

Recommended Action    No action is required.

Error Message     FSPF-6-INTF_OPER_DOWN: Down on interface [chars] 

Explanation    FSPF has become operationally down on interface [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-INTF_OPER_UP: Up on interface [chars] 

Explanation    FSPF has become operational on interface [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-MAX_AGE: LSR [dec] reached Maxage 

Explanation    The LSR for domain [dec] reached the maximum age and will be deleted from all the connected switches .

Recommended Action    No action is required.

Error Message     FSPF-6-ROLLOVER: Rolling over the incarnation number of Local LSR 

Explanation    The incarnation number of local LSR reached the maximum value and is rolling over.

Recommended Action    No action is required.

Error Message     FSPF-6-SELF_ORIGINATED: Received local LSR with higher incarnation 
number 

Explanation    A LSR for the local domain was received with incarnation number higher than the one in database. This situation should only occur initially on a topology change. If this situation persists the domain assignment of switches may not be unique

Recommended Action    If this message is received continuously check if domain assignment is unique in the fabric.

Error Message     FSPF-6-STATE_CREATED: Internal state created [chars] 

Explanation    FSPF has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-VSAN_OPER_DOWN: Down on vsan 

Explanation    FSPF has become operationally down on VSAN.

Recommended Action    No action is required.

Error Message     FSPF-6-VSAN_OPER_UP: Up with local domain [dec] 

Explanation    FSPF has started with local domain [dec].

Recommended Action    No action is required.

FSPF-7

Error Message     FSPF-7-ROUTE_THREAD_STARTED: Thread number [dec] started 

Explanation    Route computation thread number [dec] has been started for FSPF.

Recommended Action    No action is required.

FWM Messages

This section contains the FWM messages.

FWM-0

Error Message    FWM-0-FCFIB_EMERG: [chars] 

Explanation    Fcfib caused a system failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-1

Error Message     FWM-1-FCFIB_ALERT: [chars] 

Explanation    Fcfib caused failures in other services

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-1-FCFIB_HW_NO_VSAN_DOM: No hardware [chars] resources for route 
creation to VSAN [dec] Domain [dec] 

Explanation    Hardware does not have sufficient resources to create this route.

Recommended Action    Please delete unused VSANs or assign common Domain numbers to existing VSANs.

Error Message     FWM-1-FCFIB_HW_NO_VSAN: No hardware [chars] resources for route 
creation to VSAN [dec] 

Explanation    Hardware does not have sufficient resources to create this route.

Recommended Action    Please delete unused VSANs.

Error Message     FWM-1-FCFIB_HW_PC_LIMIT: Failed to create [chars], hardware limit of 
[dec] would be exceeded 

Explanation    The number of hardware SAN Port Channels is limited by the platform.

Recommended Action    Please configure fewer SAN Port Channels.

Error Message     FWM-1-FCFIB_LICENSE_UNAVAILABLE: License: [chars] is not installed. 
System will not provide FC switching. 

Explanation    Fibre Channel license is unavailable. System will not provide FC switching.

Recommended Action    Please install the license file to continue using the feature.

FWM-2

Error Message     FWM-2-FCFIB_CRIT: [chars] 

Explanation    Fcfib encountered a catastrophic error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-FWM_ASSERT_FAILURE: stack [[chars]] 

Explanation    Critical assertion failed in forwarding manager

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-FWM_CONFIG_ERROR: Wrong configuration. Ignoring configuration. 

Explanation    Configuration specified by the user is wrong. Configuration will be ignored.

Recommended Action    No action is required.

Error Message     FWM-2-FWM_OIFL_MCAST_IDX_LIMIT_REACHED: [chars] 

Explanation    The number of of multicast indices in the system have been exhausted. Cannot learn any more new multicast groups or create new vlans.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_LEARNING_RE_ENABLE: Re enabling dynamic learning on all 
interfaces 

Explanation    Re enabling learning on all interfaces after disable period expired

Recommended Action    No action is required.

Error Message     FWM-2-STM_LIMIT_REACHED: [chars] 

Explanation    System station table reached its capacity - no further MAC addresses could be programmed - administration intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_LOOP_DETECT: [chars] 

Explanation    System detected loops in the network - administration intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_MCAST_PROG_RE_ENABLE: Re enabling programming multicast 
entries 

Explanation    Re enabling programming new multicast entries because number of entries reached below threshold

Recommended Action    No action is required.

Error Message     FWM-2-STM_RAPID_MOVES: [chars] 

Explanation    System detected rapid mac moves in the network - administrator intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-3

Error Message     FWM-3-FCFIB_ERR: [chars] 

Explanation    Fcfib encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-3-FCFIB_NO_MEM: Out of memory 

Explanation    Fcfib does not have enough memory to continue proper operation.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-4

Error Message     FWM-4-FCFIB_CPU_HOG: Inactive or busy 

Explanation    Either fcfib was not scheduled to run, or fcfib was busy, and fcfib did not service the message or timer queue for an extended period.

Recommended Action    Please perform 'debug fwm error', then recreate the operation scenario, to find out more details.

Error Message     FWM-4-FWM_DUPLICATE_UNICAST_MAC_REGISTRATION: Unicast MAC address 
[chars] vlan [dec] registered on interface [chars] before deregistering on 
interface [chars]

Explanation    Duplicat unicast MAC registration observed

Recommended Action    No action is required.

Error Message     FWM-4-STM_LEARNING_OVERLOAD: [chars] 

Explanation    System getting overloaded due to learning processes

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-6

Error Message     FWM-6-MAC_MOVE_NOTIFICATION: Host [chars] in vlan [dec] is flapping 
between port [chars] and port [chars] 

Explanation    Notification of a MAC address moving as per configuration

Recommended Action    No action is required.

Error Message     FWM-6-STM_THRESHOLD_NOTIFICATION: Station table reached [dec]% of the 
total capacity (total entries [dec]) 

Explanation    Station table capacity utilization message as per configured threshold values

Recommended Action    No action is required.

GLBP Messages

This section contains the GLBP messages.

GLBP-2

Error Message    GLBP-2-GLBP_URIB_INIT_ERROR: [chars] 

Explanation    Unicast routing initialization failed and the GLBP process terminated

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

GLBP-3

Error Message     GLBP-3-GLBP_ARP_ADD_FAILED: failed to add [chars]/[chars] in arp 
table 

Explanation    The system was unable to add the GLBP vIP into the arp table

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

Error Message     GLBP-3-GLBP_ARP_DEL_FAILED: failed to delete [chars]/[chars] in arp 
table 

Explanation    The system was unable to delete the GLBP vIP from the arp table

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

Error Message     GLBP-3-GLBP_FEATURE_MANAGER_ERROR: [chars]: [chars] 

Explanation    There was a problem in GLBP interaction with feature manager.

Recommended Action    Please check the reason for error using feature manager and rectify the problem

Error Message     GLBP-3-GLBP_IP_JOIN_GROUP_FAILED: [chars]: failed to join glbp 
multicast address group 

Explanation    The system was unable to peform a join to start receiving GLBP protocol packets.

Recommended Action    Please check syslog messages for IP failures and rectify the problem

Error Message     GLBP-3-GLBP_IP_LEAVE_GROUP_FAILED: [chars]: failed to leave glbp 
multicast address group 

Explanation    The system was unable to peform a leave to stop receiving GLBP protocol packets.

Recommended Action    Please check syslog messages for IP failures and rectify the problem

Error Message     GLBP-3-GLBP_MAC_ADD_FAILED: fwd [dec] failed to add [chars] in mac 
table (error [hex]) 

Explanation    The system was unable to add the GLBP mac address into the mac addresss table

Recommended Action    Please check syslog messages for L2FM failures and rectify the problem

Error Message     GLBP-3-GLBP_MAC_DEL_FAILED: fwd [dec] failed to delete [chars] in mac 
table (error [hex]) 

Explanation    The system was unable to delete the GLBP mac address from the mac addresss table

Recommended Action    Please check syslog messages for L2FM failures and rectify the problem

Error Message     GLBP-3-GLBP_ROUTE_ADD_FAILED: failed to add [chars] in routing table 

Explanation    The system was unable to add the GLBP vIP address into the unicast routing table

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

Error Message     GLBP-3-GLBP_ROUTE_DEL_FAILED: failed to delete [chars] in routing 
table 

Explanation    The system was unable to delete the GLBP vIP address from the unicast routing table

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

GLBP-4

Error Message     GLBP-4-BADAUTH: Bad authentication received from [chars] 

Explanation    Two routers participating in a Gateway Load Balancing Protocol group have a valid authentication string that does not match.

Recommended Action    Use the glbp authentication interface command to repair the Gateway Load Balancing Protocol authentication discrepancy between the local system and the one whose IP address is reported

Error Message     GLBP-4-BADVIP1: address [chars] is in the wrong subnet for this 
interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address is not within the subnet configured on this interface.

Recommended Action    Configure the virtual IP address of Gateway Load Balancing Protocol to be within the subnet configured on this interface.

Error Message     GLBP-4-BADVIP2: address [chars] in the wrong subnet for this interface 
is not learned 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is not within the subnet configured on this interface.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-BADVIP3: address [chars] is the broadcast address for this 
interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address is a broadcast address for this interface.

Recommended Action    Configure the virtual IP address of Gateway Load Balancing Protocol to be a non broadcast address.

Error Message     GLBP-4-DIFFVIP1: active router virtual IP address [chars] is different 
from the locally configured virtual IP address [chars]

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the Hello message from the Active router is different to that configured locally.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers

Error Message     GLBP-4-DUPADDR: Duplicate address on [chars] 

Explanation    The IP address in a Gateway Load Balancing Protocol message received on the interface is the same as the IP address of its own router. This condition may be caused by a misconfiguration or because of a malfunctioning switch.

Recommended Action    Check the configurations on all the Gateway Load Balancing Protocol routers, and ensure that any switches are functioning properly

Error Message     GLBP-4-DUPVIP1: address [chars] already assigned to interface [chars] 
grp [dec] 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to a different Gateway Load Balancing Protocol group.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers

Error Message     GLBP-4-DUPVIP2: address [chars] already assigned to this interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to this interface.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-DUPVIP3: address [chars] already assigned to another interface 
[chars] 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to, or overlaps with, an address on another interface or application.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-GLBP_ARP_RESP_FAILED: failed to send arp response 
[chars]/[chars] 

Explanation    The system was unable to send the arp response for vIP

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

GLBP-5

Error Message     GLBP-5-ACTIVE_CHANGE: Active gateway is [chars] 

Explanation    The Gateway Load Balancing Protocol has changed active gateway.

Recommended Action    No action is required

Error Message     GLBP-5-FWDSTATECHANGE: fwd [dec] state changed from [chars] to [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed state.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_CREATE: fwd [dec] created 

Explanation    The Gateway Load Balancing Protocol forwarder has been created.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_DELETE: fwd [dec] deleted 

Explanation    The Gateway Load Balancing Protocol forwarder has been removed.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_OWNER: fwd [dec] owner mac is [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the owner MAC address.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_VMAC: fwd [dec] virtual mac is [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the virtual MAC address.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_WEIGHTING: fwd [dec] weighting is [dec] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the weighting.

Recommended Action    No action is required

Error Message     GLBP-5-GRPSTATECHANGE: state changed from [chars] to [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has changed state.

Recommended Action    No action is required

Error Message     GLBP-5-MEMBER_ADD: member [chars] [chars] added 

Explanation    The Gateway Load Balancing Protocol gateway has added a member.

Recommended Action    No action is required

Error Message     GLBP-5-MEMBER_REMOVE: member [chars] [chars] removed 

Explanation    The Gateway Load Balancing Protocol gateway has removed a member.

Recommended Action    No action is required

Error Message     GLBP-5-PRIORITY: [chars] gateway priority changed to [dec] 

Explanation    The Gateway Load Balancing Protocol gateway has changed priority.

Recommended Action    No action is required

Error Message     GLBP-5-STANDBY_CHANGE: Standby gateway is [chars] 

Explanation    The Gateway Load Balancing Protocol has changed standby gateway.

Recommended Action    No action is required

Error Message     GLBP-5-TIMER: [chars] timer changed to [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has learnt timers.

Recommended Action    No action is required

Error Message     GLBP-5-VIPLEARN: learnt virtual ip address [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has learnt virtual IP address.

Recommended Action    No action is required

Error Message     GLBP-5-VIPUNLEARN: unlearnt virtual ip address [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has unlearnt virtual IP address.

Recommended Action    No action is required

Error Message     GLBP-5-WEIGHTING: weighting changed to [dec] 

Explanation    The Gateway Load Balancing Protocol gateway has changed the weighting.

Recommended Action    No action is required

HSRP_ENGINE Messages

This section contains the HSRP_ENGINE messages.

HSRP_ENGINE-3

Error Message    HSRP_ENGINE-3-NOSOCKET: Unable to open socket 

Explanation    The system was unable to initialize an IP connection for the Hot Standby protocol.

Recommended Action    Make sure that there is at least one interface configured to run IP.

HSRP_ENGINE-4

Error Message     HSRP_ENGINE-4-BADAUTH2: Bad authentication from [chars] 

Explanation    Two routers participating in HSRP disagree on the valid authentication string.

Recommended Action    Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.

Error Message     HSRP_ENGINE-4-BADAUTH: Bad authentication from [chars], group [dec], 
remote state [chars] 

Explanation    Two routers participating in HSRP disagree on the valid authentication string.

Recommended Action    Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.

Error Message     HSRP_ENGINE-4-DIFFVIP1: [chars] Grp [dec] active routers virtual IP 
address [chars] is different to the locally configured address [chars]

Explanation    The HSRP virtual IP address contained in the Hello message from the Active router is different to that configured locally.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPADDR: Duplicate address %i on [chars], sourced by %e 

Explanation    The IP address in an HSRP message received on the interface is the same as the router's own IP address. This may be because of misconfiugration, or because of a malfunctioning switch

Recommended Action    Check the configurations on all the HSRP routers, and make sure that any switches you have are functioning properly.

Error Message     HSRP_ENGINE-4-DUPVIP1: [chars] Grp [dec] address [chars] is already 
assigned to a HSRP group on this interface

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different HSRP group.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPVIP2: [chars] Grp [dec] address [chars] is already 
assigned on this interface

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPVIP3: [chars] Grp [dec] address [chars] is already 
assigned to, or overlaps with, an address on another interface or application

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with, an address on another interface or application.

Recommended Action    Check the configuration on all HSRP routers.

HSRP_ENGINE-6

Error Message     HSRP_ENGINE-6-ACTIVEROUTERPRIORITY: Interface [chars] [chars] Grp 
[dec] Active router priority changed to [dec] 

Explanation    The priority of the Active router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-ACTIVE_CHANGE: Interface [chars] [chars] Grp [dec] 
Active router is [chars] 

Explanation    The Active router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-GRPSTATECHANGE: Interface [chars] [chars] Grp [dec] 
state changed from [chars] to [chars] reason [chars] 

Explanation    The HSRP router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-MACADDRESS_CHANGE: Interface [chars] [chars] Grp [dec] 
mac-address changed to [chars] 

Explanation    The mac address of the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-PRIORITY: Interface [chars] [chars] Grp [dec] priority 
changed to [dec] 

Explanation    The current priority of the HSRP group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STANDBYROUTERPRIORITYCHANGE: Interface [chars] [chars] 
Grp [dec] Standby router priority changed to [dec] 

Explanation    The priority of the Standby router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STANDBY_CHANGE: Interface [chars] [chars] Grp [dec] 
Standby router is [chars] 

Explanation    The Standby router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STATECHANGE2: [chars] Grp [dec] state moving from 
[chars] 

Explanation    The router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STATECHANGE: [chars] Grp [dec] state move to [chars] 

Explanation    The router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-TIMER: Interface [chars] [chars] Grp [dec] [chars] 
timer changed to [dec] [chars] 

Explanation    The hello/hold timer value for the HSRP group has changed

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-VIPLEARN: Interface [chars] [chars] Grp [dec] learnt 
virtual ip address [chars] 

Explanation    The local router has learnt virtual ip address from the incoming HSRP packet.

Recommended Action    No action is required.

IKE Messages

This section contains the IKE messages.

IKE-3

Error Message    IKE-3-CRYPTO_INIT_ERROR: IKEv2 crypto init error: [chars] 

Explanation    Crypto initialization error

Recommended Action    No action is required.

Error Message     IKE-3-ENABLE_ERROR: Unable to store enable flag in configuration 
(error-id [hex]).

Explanation    Service failed to store the enable flag in configuration. As a result, it will exit

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IKE-3-FIPS_MODE_ERROR: Could not set FIPS mode 

Explanation    The FIPS mode could not be set by IKE

Recommended Action    No action is required.

Error Message     IKE-3-IKE_PROGRAM_EXIT: [chars] 

Explanation    IKE process did an abnormal exit

Recommended Action    No action is required.

Error Message     IKE-3-MAX_HALF_CONN_LIMIT_REACHED: IKEv1 : Exceeded the limit for 
number of half open Phase 1 connections 

Explanation    The number of half open connections has exceeded the maximum limit

Recommended Action    No action is required.

Error Message     IKE-3-PHASE1_NEGOTIATION_FAILED: IKEv1: Phase 1 negotiation failed 
for peer [chars] 

Explanation    IKE policy negotiation failed for peer [chars].

Recommended Action    No action is required.

Error Message     IKE-3-PHASE1_PROPOSAL_MISMATCH: IKEv1: No matching phase 1 proposal 
found for peer [chars] 

Explanation    There is a IKE policy mismatch for the peer.

Recommended Action    No action is required.

Error Message     IKE-3-PHASE2_NEGOTIATION_FAILED: IKEv1: Phase 2 negotiation failed 
for peer [chars] 

Explanation    IPsec policy negotiation failed for peer [chars].

Recommended Action    No action is required.

Error Message     IKE-3-PHASE2_PROPOSAL_MISMATCH: IKEv1: No matching phase 2 proposal 
found for peer [chars] 

Explanation    There is a IPsec policy mismatch for the peer.

Recommended Action    No action is required.

Error Message     IKE-3-UNSUPPORTED_EXCHANGE: IKEv1: Unsupported exchange [dec] 
received from [chars] 

Explanation    A unsupported IKE exchange type [digits] was received from [chars]

Recommended Action    No action is required.

IKE-4

Error Message     IKE-4-INVALID_PAYLOAD_APPEAR: IKEv2 received message (from [chars]) 
with payload ([chars]) appeared in [chars]([chars]) 

Explanation    Received a payload in an inappropriate exchange

Recommended Action    No action is required.

Error Message     IKE-4-MESSAGE_ERROR: IKEv2 message (from [chars]) message error: 
[chars] 

Explanation    Received a malformed message which doesn't adhere to the protocol

Recommended Action    No action is required.

Error Message     IKE-4-PARSING_ERROR: IKEv2 message (from [chars]) parsing error: 
[chars] 

Explanation    Received a malformed message which can not be parsed appropriately

Recommended Action    No action is required.

Error Message     IKE-4-UNKNOWN_PAYLOAD: IKEv2 received message (from [chars]) with 
un-recognized payload ([chars]) 

Explanation    Received an invalid payload

Recommended Action    No action is required.

Error Message     IKE-4-UNSUPPORT: [chars] is not supported (message from [chars]) 

Explanation    Received something unsupported

Recommended Action    No action is required.

IKE-6

Error Message     IKE-6-POLL_START_DONE: IKE is exiting since it is not enabled 

Explanation    IKE is exiting since it is not enabled in the configuration

Recommended Action    No action is required.

ILC-SPAN Messages

This section contains the ILC-SPAN messages.

ILC-SPAN-3

Error Message    ILC-SPAN-3-ERROR: [chars] 

Explanation    Ilc_span_mgr encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

ILC_HELPER Messages

This section contains the ILC-HELPER messages.

ILC_HELPER-2

Error Message    ILC_HELPER-2-NO_LICENSE_REBOOT: Linecard [dec] will reboot now. 

Explanation    SSE License has expired, hence the linecard will be rebooted.

Recommended Action    Install appropriate SSE license to be able to use SSM features normally

ILC_HELPER-3

Error Message     ILC_HELPER-3-INVALID_SSI: [chars] 

Explanation    The ssi boot variable is configured to an invalid image. So, the linecard will be bought online in basic mode instead of advanced SSI mode

Recommended Action    Configure a proper image for the ssi boot variable

ILC_HELPER-6

Error Message     ILC_HELPER-6-LICENSE_VALID: A valid license for linecard [dec] has 
been obtained 

Explanation    A valid license has been obtained for the SSM

Recommended Action    No action is required.

Error Message     ILC_HELPER-6-UPGRADE_DELAY: The SSI upgrade on slot [dec] is delayed 
by [dec] secs. 

Explanation    The SSI upgrade is delayed due to the configured ssm upgrade delay command

Recommended Action    No action is required.

IMAGE_DNLD Messages

This section contains the IMAGE_DNLD messages.

IMAGE_DNLD-SLOT#-2

Error Message    IMAGE_DNLD-SLOT#-2-ADDON_IMG_DNLD_FAILED: Module image download 
process failed. [chars] 

Explanation    Addon image download to module failed. This module is not operational until an addon image has been successfully installed.

Recommended Action    Verify the location and version of your module image. Use the install module cli command to download a new module image.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_COMPLETE: Module image download process. 
[chars] 

Explanation    Image download completed. Module image is being installed.

Recommended Action    No action is required.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_FAILED: Module image download process. 
[chars] 

Explanation    Image download failed. Module may be inoperable.

Recommended Action    Use show module cli command to verify the state of this module. Retry image download with install module cli command.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_FILE_SYSTEM_CHECK_ERROR: File System 
check failed: [chars] 

Explanation    File system consistency check failed

Recommended Action    File-system repair is needed using fsck

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_STARTED: Module image download process. 
[chars] 

Explanation    Image download started. Module image downloads are non-disruptive to module operation.

Recommended Action    No action is required.

IMAGE_DNLD-SLOT#-4

Error Message     IMAGE_DNLD-SLOT#-4-IMG_DNLD_FILE_SYSTEM_RECREATION: [chars]. 
Partition was erased and successfully recreated. 

Explanation    File system checking and recreation if necessary for \/images\.

Recommended Action    No action is required.

IMAGE_DNLD-SLOT#-5

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_COMPLETE: Addon module image 
download process completed. [chars] 

Explanation    Addon image download to module has completed.The module should now be installing this new image.

Recommended Action    This message is informational only.

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_STARTED: Addon module image 
download process started. [chars] 

Explanation    Addon image download to module has started. This is a disruptive download and this module will be inoperable until this download process is complete.

Recommended Action    This message is informational only.

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_SUCCESSFUL: Addon module image 
download and install process successful. [chars] 

Explanation    Addon image download and install to module is successful.

Recommended Action    Use the show module cli command to verify the module's operational status.

IMAGE_UPGRADE Messages

This section contains the IMAGE_UPGRADE messages.

IMAGE_UPGRADE-SLOT#-2

Error Message    IMAGE_UPGRADE-SLOT#-2-IMAGE_UPGRADE_ERROR: [chars] 

Explanation    Image Upgrade Error

Recommended Action    No action is required.

IMAGE_UPGRADE-SLOT#-4

Error Message     IMAGE_UPGRADE-SLOT#-4-IMAGE_UPGRADE_INFO: [chars] 

Explanation    Image Upgrade Info

Recommended Action    No action is required.

IM Messages

This section contains the IM messages.

IM-3

Error Message    IM-3-IM_LC_OFFLINE_ERROR: LC Offline could not be sent to vdc:[dec] 

Explanation    LC Offline was not relayed to some vdc, so applications may not behave correctly.

Recommended Action    No action is required.

Error Message     IM-3-IM_RESP_ERROR: Component [chars] opcode:[chars] in vdc:[dec] 
returned error:[chars] 

Explanation    Some component returned an error.

Recommended Action    No action is required.

Error Message     IM-3-IM_SEQ_ERROR: Error ([chars]) while communicating with component 
[chars] opcode:[chars] (for:[chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    No action is required.

IM-5

Error Message     IM-5-IM_DEMUX_ERROR: [chars] 

Explanation    Demux function returned error

Recommended Action    No action is required.

Error Message     IM-5-IM_INTERNAL_ERROR: [chars] 

Explanation    Internal error occurred

Recommended Action    No action is required.

Error Message     IM-5-IM_INTF_STATE: [chars] [chars] in vdc [dec] 

Explanation    Management interface state changed.

Recommended Action    No action is required.

Error Message     IM-5-IM_UNKNOWN_INTERFACE: [chars] 

Explanation    Interface is not supported or not found

Recommended Action    No action is required.

INTERFACE_VLAN Messages

This section contains the INTERFACE_VLAN messages.

INTERFACE_VLAN-5

Error Message    INTERFACE_VLAN-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is 
down(Administratively Down) 

Explanation    Interface has been configured to be administratively down

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-IF_DOWN_ERROR_DISABLED: Interface [chars] is down. 
Reason [dec] 

Explanation    The interface encountered an error while configuring it

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-IF_DOWN_INACTIVE: Interface [chars] is down 
(Inactive) 

Explanation    Interface VLAN has been suspended or deleted

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_DISABLED: SVI Disabled 

Explanation    SVI Service Disabled

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_ENABLED: SVI Enabled 

Explanation    SVI Service Enabled

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_GET_MAC_FAILED: Failed to acquire MAC address 
for SVI [hex] 

Explanation    SVI failed to acquire MAC address

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_INIT: SVI intialization failed with error [hex] 

Explanation    SVI initialziation error

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_MTS_SEND_FAILURE: MTS send failure for opcode 
[dec], error [hex] 

Explanation    SVI encountered an error in with MTS message

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_MTS_TIME_OUT: MTS send timed out 

Explanation    SVI did not recieve response for mts message

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_RSRVD_VLAN_FAILED: Failed to get list of 
reserved vlans [hex] 

Explanation    SVI failed to get the list reserved vlans

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_SDB_UPDATE_FAILED: sdb update failed with 
ret_val [dec] 

Explanation    SDB updated failed for SVI

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_SEC_VLAN_FAILED: Failed to get list of secondary 
vlans [hex] 

Explanation    SVI failed to get the list of secondary vlans

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-UPDOWN: Line Protocol on Interface [chars], changed 
state to [chars] 

Explanation    Line protocol status changed for an interface

Recommended Action    No action is required.

IOA_LC Messages

This section contains the IOA_LC messages.

IOA_LC-5

Error Message    IOA_LC-5-IOA_DISABLED: IOA Disabled 

Explanation    IOA Service Disabled

Recommended Action    No action is required.

Error Message     IOA_LC-5-IOA_ENABLED: IOA Enabled 

Explanation    IOA Service nabled

Recommended Action    No action is required.

IPACL Messages

This section contains the IPACL messages.

IPACL-0

Error Message    IPACL-0-EMERG: [chars] 

Explanation    Ipacl caused a system failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-1

Error Message     IPACL-1-ALERT: [chars] 

Explanation    Ipacl caused failures in other services

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-2

Error Message     IPACL-2-CRIT: [chars] 

Explanation    Ipacl encountered a catastrophic error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPACL-3-ERR: [chars] 

Explanation    Ipacl encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-4

Error Message     IPACL-4-WARN: [chars] 

Explanation    Ipacl ignored the unexpected condition

Recommended Action    Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.

IPACL-5

Error Message     IPACL-5-NOTE: [chars] 

Explanation    Ipacl does not support this operation

Recommended Action    Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.

IPACL-6

Error Message     IPACL-6-INFO: [chars] 

Explanation    Ipacl event occurred

Recommended Action    No action is required.

IPFC Messages

This section contains the IPFC messages.

IPFC-2

Error Message    IPFC-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IPFC-3

Error Message     IPFC-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

Error Message     IPFC-3-IOCTL_FAILED: IOCTL failed 

Explanation    An IOCTL to the character device failed.

Recommended Action    Show IPFC internal interface VSAN <number> for all the configured VSAN interfaces to check the internal status, show IPFC internal MIP to check the internal status.

Error Message     IPFC-3-PSSERROR: [chars] 

Explanation    IPFC manager encountered a PSS error.

Recommended Action    No action is required.

IPFC-5

Error Message     IPFC-5-CONFIG_EVENT: VSAN interface [dec] [chars] 

Explanation    The specified VSAN Interface has been successfully [chars].

Recommended Action    No action is required.

Error Message     IPFC-5-STATE_CHANGE: VSAN interface [dec] [chars] 

Explanation    The specified VSAN Interface is [chars].

Recommended Action    No action is required.

IPFC-6

Error Message     IPFC-6-STARTING: IP Over Fiber Channel service started 

Explanation    The service has successfully started.

Recommended Action    No action is required.

IPPOOL Messages

This section contains the IPPOOL messages.

IPPOOL-3

Error Message    IPPOOL-3-NO_VC_CONNECTIVITY: Please check if you are connected to 
vCenter Server 

Explanation    Please check if you are connected to vCenter Server

Recommended Action    No action is required.

IPPOOL-5

Error Message     IPPOOL-5-IPPOOL_DISABLED: IPPOOL Disabled 

Explanation    IPPOOL Service Disabled

Recommended Action    No action is required.

Error Message     IPPOOL-5-IPPOOL_ENABLED: IPPOOL Enabled 

Explanation    IPPOOL Service enabled

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_CREATED: Vmknic Created for module [dec] 

Explanation    Vmknic created

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_DELETED: Vmknic Deleted for module [dec] 

Explanation    Vmknic deleted

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_UPDATED: Vmknic updated for module [dec] 

Explanation    Vmknic updated

Recommended Action    No action is required.

IPQOSMGR Messages

This section contains the IPQOSMGR messages.

IPQOSMGR-2

Error Message    IPQOSMGR-2-QOSMGR_HA_FAILURE: Failed to do high availability 
operation: [chars]. 

Explanation    Failed to do high availability operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_INIT_FAILED: Initialization failed for QoS Manager: 
[chars], reason: [hex]. 

Explanation    Initialization failed for QoS Manager due to [chars], reason: [hex].

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_MTS_FAILURE: Failed to do MTS operation: [chars]. 

Explanation    Failed to do MTS operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_MTS_REGISTRATION_FAILED: MTS options setting to 
[hex] failed for opCode: [dec]. 

Explanation    MTS options setting to [hex] failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_PSS_FAILURE: Failed to do PSS operation: [chars], 
reason: [hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec]. 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.

Recommended Action    No action is required.

IPQOSMGR-3

Error Message     IPQOSMGR-3-QOSMGR_CONFIG_ERROR: Configuration error: [chars]. 

Explanation    Configuration error. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-3-QOSMGR_PPF_ERROR: PPF library error: [chars]. 

Explanation    PPF library errors. [chars] is the reason.

Recommended Action    No action is required.

IPQOSMGR-4

Error Message     IPQOSMGR-4-QOSMGR_LC_ERROR_MSG: Linecard [dec] returned an error: 
[chars] 

Explanation    Linecard [dec] returned an error message which is reported as [chars].

Recommended Action    No action is required.

Error Message     IPQOSMGR-4-QOSMGR_PPF_WARNING: PPF library warning: [chars]. 

Explanation    PPF library warning. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-4-QOSMGR_WARNING_MSG: [chars] [dec] 

Explanation    QOSMGR warning messages is reported as [chars] [dec].

Recommended Action    No action is required.

IPQOSMGR-6

Error Message     IPQOSMGR-6-QOSMGR_STATUS: QOSMGR Status: [chars]. 

Explanation    QOSMGR status is reported as [chars].

Recommended Action    No action is required.

IPQOSMGR-SLOT#-3

Error Message     IPQOSMGR-SLOT#-3-QOSMGR_DPA_MSG: DPA returned error message - [chars] 

Explanation    An error occured in the DPA [string] is the error message.

Recommended Action    No action is required.

IPSEC Messages

This section contains the IPSEC messages.

IPSEC-2

Error Message    IPSEC-2-IPSEC_INIT: IPSec initialization of [chars] [chars] 

Explanation    IPSec initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPSEC-2-IPSEC_SPD_OVERFLOW_DUE_TO_ACL: SPD Overflow on interface due 
to IP ACL [chars] bound to crypto map [chars] [dec]

Explanation    Modifying IP ACL caused Security Policy Database on the interface to overflow, IP ACL filter not applied to security policy database

Recommended Action    Undo IP ACL change

IPSEC-3

Error Message     IPSEC-3-14_2_MODULE_PACKETS_DROPPED: [chars]: packets were dropped in 
the module 

Explanation    Packets dropped in the 14/2 module. Please collect drop statistics using \show ipsec internal crypto-acc interface gigabit <slot/port> stats\

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPSEC-3-IPSEC_FIPS_TEST_FAILED: IPSEC FIPS compliance test failed 

Explanation    IPSEC FIPS compliance test failed

Recommended Action    No action is required.

Error Message     IPSEC-3-IPSEC_MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: 
[chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

IPSEC-5

Error Message     IPSEC-5-IPSEC_CMS_IF_ACL_UPDATED: IP ACL [chars] updated while Crypto 
map [chars] [dec] bound to interface(s)

Explanation    IP ACL updated while it is mapped to a crypto map that is bound to interface(s)

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_DISABLED_LIC_EXPIRED: IPSec Disabled due to License 
Expiry 

Explanation    IPSec Disabled due to License Expiry

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_DISABLED: IPSec Disabled 

Explanation    IPSec Disabled

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_ENABLED: IPSec Enabled 

Explanation    IPSec Enabled

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_CREATED: [chars]: IPSec SA created: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]) 

Explanation    IPSec SA created

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_DELETED: [chars]: IPSec SA deleted: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]), reason: [chars] 

Explanation    IPSec SA deleted

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_REKEYED: [chars]: IPSec SA rekeyed: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]) 

Explanation    IPSec SA rekeyed

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_CREATED: [chars]: IPSec tunnel created: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: 
local: [chars]/[chars], port: [chars], remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel created

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_DELETED: [chars]: IPSec tunnel deleted: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: 
local: [chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel deleted

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_REKEYED: [chars]: IPSec tunnel rekeyed: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars] traffic:: local: 
[chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel rekeyed

Recommended Action    No action is required.

IPS_SB_MGR Messages

This section contains the IP_SB_MGR messages.

IPS_SB_MGR-SLOT#-2

Error Message    IPS_SB_MGR-SLOT#-2-NODE_CORE_NOT_RESPONDING: [Node [dec], Core 
[dec]]: Not responding to heartbeats, state=[hex] 

Explanation    Node is not incrementing heartbeats periodically

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-NODE_NOT_RESPONDING: [Node [dec], Core [dec]] : 
Not responding to heartbeats 

Explanation    Node manager is not receiving heartbeat responses from the node

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-NODE_REIMAGE_PREPARE_FAIL: [Node [dec]]: Disk 
formatting failed during node install 

Explanation    There was a problem during the partitioning of disk and creation of file systems during node install.

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-PORT_SOFTWARE_FAILURE: Port software failure, 
module [dec] port [dec] 

Explanation    The software servicing the data path on the port has failed

Recommended Action    No action is required.

IPS_SB_MGR-SLOT#-3

Error Message     IPS_SB_MGR-SLOT#-3-COMP_FAILURE: Heartbeat failure in compression 
engine (error [hex]) 

Explanation    The compression engine did not respond to heartbeats, due to some failure. SAN-OS will restart the compression engine to clear the problem.

Recommended Action    No action is required.

Error Message     IPS_SB_MGR-SLOT#-3-CRYPTO_FAILURE: Heartbeat failure in encryption 
engine (error [hex]) 

Explanation    The encryption engine did not respond to heartbeats, due to some failure. SAN-OS will restart the encryption engine to clear the problem.

Recommended Action    No action is required.

IPS_SB_MGR-SLOT#-4

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_ADD_ON: svc-node[dec] image 
is not compatible with svclc image 

Explanation    The svc image on the node is not compatible with the add on image running on the linecard.

Recommended Action    Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_CURRENT: svc-node[dec] image 
is not compatible with current node image 

Explanation    The new svc image is not compatible with the svc image currently running on the node

Recommended Action    Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_SUP: svc-node[dec] image is 
not compatible with system image 

Explanation    The svc image on the node is not compatible with the supervisor image.

Recommended Action    Please contact your support representative

IPS_SB_MGR-SLOT#-6

Error Message     IPS_SB_MGR-SLOT#-6-SBMGR_EVENT: Sbmgr event: [chars] 

Explanation    This is an event log of sb_mgr relating to a port/node

Recommended Action    No action is required.

IPS Messages

This section contains the IPS messages.

IPS-2

Error Message    IPS-2-ISCSI_IPS_INIT: IPS initialization of [chars] [chars] 

Explanation    IPS initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPS-3

Error Message     IPS-3-FCIP_FTA_ACCEL_CHAIN_ABORTED: Exch Aborted FC oxid [hex] My 
oxid [hex] State [chars] Event [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] 
CUI: [hex] DA [hex] VSAN: [dec] (Internal [hex]:[hex])

Explanation    FTA Exch being aborted

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_DATA_SENSE: Sense data with ERA [hex] sent to CH FCID: 
[hex] CHI: [hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Sense data with ERA sent

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_ERA_35: ERA [hex] presented to CH FCID: [hex] CHI: 
[hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP got an ERA 35

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_ERA_38: ERA 0x38 received CH FCID: [hex] CHI: [hex] 
from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] at tape capacity: [dec] MB

Explanation    FCIP got an ERA 38

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_LOCATE_RBID_MISMATCH: Permanent Error due to Locate 
RBID Mismatch, CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: 
[dec]

Explanation    FCIP-FTA got a Permanent Error

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_PERM_ERR: Permanent Error, ERA [hex] rcvd CH FCID: 
[hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] sense_byte[2,6]: 
[[hex], [hex]]

Explanation    FCIP-FTA got a Permanent Error

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_RETRY_ERROR: [chars] retries [dec] FC oxid [hex] My 
oxid [hex] State [chars] Event [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] 
CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FTA Command timed out

Recommended Action    Informational no action required

Error Message     IPS-3-IPS_CRYPTO_FIPS_FAILED: IPS module [dec] has failed FIPS tests. 
FIPS info - [chars] 

Explanation    FIPS error occurred in the IPS module.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-IPS_EGRESS_PERR: Parity error on dma-bridge egress. Count: 
[dec] 

Explanation    Parity error occured in dma-bridge egress direction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-IPS_FIPS_TEST_FAILED: IPS FIPS compliance test failed 

Explanation    IPS FIPS compliance test failed

Recommended Action    No action is required.

Error Message     IPS-3-IPS_INGRESS_PERR: Parity error on dma-bridge ingress. Count: 
[dec] 

Explanation    Parity error occured in dma-bridge ingress direction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_COMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while commiting the cfs config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_CONFIG_FAILED: [chars]; [chars] 

Explanation    An error occurred while distributing the CFS config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_ACTIVATION_FAILED: [chars]; [chars] 

Explanation    An error occurred while activating merged configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_CLEARED: [chars] 

Explanation    Merge cleared, reason: [chars]

Recommended Action    No action is required.

Error Message     IPS-3-ISLB_CFS_MERGE_COMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while commiting the cfs merge config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_CONFIG_FAILED: [chars]; [chars] 

Explanation    An error occurred while distributing the CFS merge config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_FAILED: [chars]; [chars] 

Explanation    An error occurred while merging the iSLB CFS fabrics. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_PRECOMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while precommiting merge data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_REQ_REJECTED: [chars] 

Explanation    Merge requested rejected, reason: [chars]

Recommended Action    No action is required.

Error Message     IPS-3-ISLB_CFS_MERGING_CONFIG_DB_FAILED: [chars]; [chars] 

Explanation    An error occurred while merging the config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PRECOMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while precommiting data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PWWN_RESV_CLAIM_FAILED: [chars] 

Explanation    PWWN reservation claim failed. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PWWN_RESV_RELEASE_FAILED: [chars] 

Explanation    PWWN reservation release failed. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_VRRP_DIST_FAILED: [chars] 

Explanation    An error occurred while distributing the VRRP CFS runtime data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_ZONE_ACTIVATION_FAILED: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_ZONE_ACTIVATION_RETRY: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed. Zone server busy.

Recommended Action    Retry the iSLB zonest activation.

Error Message     IPS-3-ISLB_ZONE_NO_ACTIVE_ZONESET: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed. No active zoneset.

Recommended Action    Activate a zoneset in the specified VSAN and retry

IPS-4

Error Message     IPS-4-FCIP_FTA_CFG_MISMATCH: [chars]: Mismatch in FCIP Ficon Tape 
Acceleration configuration with peer

Explanation    The FCIP Ficon Tape Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Ficon Tape Acceleration configuration to be consistent with the peer

Error Message     IPS-4-FCIP_FTA_VSAN_UPDATE_WARNING: FCIP FICON tape acceleration VSAN 
update had an error ([chars]) on interface [chars] causing a flap of the interface

Explanation    The FCIP FICON tape acceleration VSAN configuration experienced an error when disabling and enabling the VSAN over the FCIP tunnel. The FCIP tunnel was disabled and re-enabled as a result of this error to ensure data integrity.

Recommended Action    No action is required.

Error Message     IPS-4-FCIP_LICENSE_BIND_FAILED: Bind failed for [chars] due to 
[chars] for license failure; configuration accepted but bind failed

Explanation    The FCIP configuration was accepted, but the FCIP interface did not bind to a physical interface because the appropriate license was not available. If a license becomes available in the future, this FCIP interface will bind to a physical interface automatically.

Recommended Action    Check the license state with show license usage and acquire the necessary FCIP license

Error Message     IPS-4-FCIP_XRCE_LICENSE_FAILED: XRC Acceleration deactivated due to 
license failure 

Explanation    The XRC Acceleration configuration was accepted, but will remain inactive until a valid license is available. When the appropriate license is installed, XRC accelaration will be activated.

Recommended Action    Check the license state with show license usage and acquire the necessary XRC_ACCL license

Error Message     IPS-4-FCIP_XRCE_LICENSE_INSTALLED: XRC Acceleration activated due to 
valid license 

Explanation    The XRC Acceleration configuration is activated as a valid license has been installed.

Recommended Action    No action is required.

IPS-5

Error Message     IPS-5-FCIP_BIND_FAILED: Bind failed for [chars] due to [chars] for 
[chars] 

Explanation    FCIP/ISCSI Interface bind to Ethernet port failed

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_BPORT_KEEPALIVES_NOT_SUPPORTED: Bport Keepalives not 
supported for FCIP [chars] 

Explanation    Bport Keepalives not supported in this release

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_BPORT_NOT_SUPPORTED: Bport not supported for FCIP [chars] 

Explanation    Bport not supported in this releas

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ACCEL_STARTED: Acceleration started for CH FCID: [hex] 
CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP-FTA Acceleration started

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ACCEL_STOPPED: Acceleration stopped for CH FCID: [hex] 
CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] due to [chars] after [dec] 
MB writes

Explanation    FCIP-FTA Acceleration stopped

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ALREADY_OFF: FTA Already Off, [chars] VSAN: [dec] 

Explanation    FTA Already Off

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ALREADY_ON: FTA Already ON, [chars] VSAN: [dec] 

Explanation    FTA Already ON

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_CB_DOWN: FTA [chars] is DOWN 

Explanation    FTA is DOWN

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_CB_UP: FTA [chars], is UP 

Explanation    FTA is UP

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_DISBAND_GRP_CMD: Disband Group message processed PGID: 
[chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP Disbanded a Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_EST_GRP_CMD: Path Group establised for PGID: [chars] 
CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP established a Path Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS1: RSCN Cleanup Pass1 
[chars] FCID1: [hex] FCID2: [hex] VSAN: [dec] 

Explanation    Doing RSCN Cleanup, Pass 1

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS2: RSCN Cleanup Pass2 
[chars] FCID1: [hex] FCID2: [hex] VSAN: [dec] 

Explanation    Doing RSCN Cleanup, Pass 2

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESIGN_GRP_CMD: Resign group processed for PGID: 
[chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP Resigned a Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_3490: 3490 device discovered by FCIP CH FCID: 
[hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Device type discovered is 3490

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_3590: 3590 device discovered by FCIP CH FCID: 
[hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Device type discovered is 3590

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_NOT_TAPE: Non-tape device discovered by FCIP CH 
FCID: [hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP discovered a non-tape device

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_OFF_LAST_VSAN: FTA turned off for the Last VSAN, 
[chars] VSAN: [dec] 

Explanation    FTA turned off for the Last Vsan

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_OFF_NONLAST_VSAN: FTA turned off for the Non-Last 
VSAN, [chars] VSAN: [dec] 

Explanation    FTA turned off for the Non-Last Vsan

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_ON: Turn ON FTA, [chars] VSAN: [dec] 

Explanation    FTA turned ON

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_WARNING: FTA Warning :[chars] 

Explanation    Generic FTA Warning

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_IF_CR_DEL: Interface [chars] [chars] 

Explanation    FCIP Interface was Created or Deleted

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_MODE1_CHANGED_TO_MODE2: Changing mode1 compression to 
mode2 for [chars], on a MSM/SSN-16 linecard 

Explanation    Change mode1 compression to mode2 on a MSM/SSN-16 linecard

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_NUM_TCP_CONNS_MISMATCH: [chars]: configured for 2 tcp 
connections but currently operating with 1 connection

Explanation    Number of configured tcp connections don't match number of connections currently up

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_PEER_CAVIUM: Peer FCIP [chars] is a MSM/SSN-16 linecard 

Explanation    Peer linecard is a MSM/SSN-16

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_PEER_NON_CAVIUM: Peer FCIP [chars] is a non MSM/SSN-16 
linecard 

Explanation    Peer linecard is non MSM/SSN-16

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_RA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape Read 
Acceleration capability with peer

Explanation    The FCIP Tape Read Acceleration capability does not match with peer's configuration

Recommended Action    Fix the FCIP Tape Read Acceleration capability to be consistent with the peer

Error Message     IPS-5-FCIP_SF_NOT_SUPPORTED: Special-Frame not supported for FCIP 
[chars] 

Explanation    Spl-Frame not supported in this release

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_TA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape 
Acceleration configuration with peer

Explanation    The FCIP Tape Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Tape Acceleration configuration to be consistent with the peer

Error Message     IPS-5-FCIP_TA_ITL_MISMATCH: [chars]: Mismatch in FCIP Write/Tape 
Acceleration software capability with peer

Explanation    The FCIP Write/Tape Acceleration software capability does not match with peer's software capability

Recommended Action    Fix the FCIP software to be consistent with the peer

Error Message     IPS-5-FCIP_TSTAMP_CHK_FAILED: [chars]: Timestamp check failed on 
ingressing frames 

Explanation    Timestamp between local and remote side exceeds the configured tolerance

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_UNBIND_FAILED: UNBIND failed for [chars] due to [chars] 
for [chars] 

Explanation    FCIP/ISCSI Interface UNBIND from Ethernet port failed

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_WA_CFG_MISMATCH: [chars]: Mismatch in FCIP Write 
Acceleration configuration with peer

Explanation    The FCIP Write Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Write Acceleration configuration to be consistent with the peer

Error Message     IPS-5-FCIP_WA_XFER_RDY_ERR: [chars]: FCIP Write Acceleration received 
XFER-RDY after exhcange cleanup. Host [hex] Target [hex]

Explanation    FCIP Write/Tape Acceleration received XFER-RDY after exchange cleanup

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_XRCE_CFG_MISMATCH: [chars]: Mismatch in FCIP XRC Emulator 
configuration with peer

Explanation    The FCIP XRC Emulator configuration does not match with peer's configuration

Recommended Action    Fix the FCIP XRC Emulator configuration to be consistent with the peer

Error Message     IPS-5-IPS_IPACL_LOG_MSG: [chars] 

Explanation    Details of the packet dropped due to ACLs

Recommended Action    No action is required.

Error Message     IPS-5-IPS_MGR_FEATURE_ENABLE: ips:[dec] iscsi:[dec] fcip:[dec] 
iscsi-intf-vsan:[dec] ips-lc:[dec] 

Explanation    IPS Manager feature enabled/disabled

Recommended Action    No action is required.

Error Message     IPS-5-IPS_TCP_PORT_IN_USE: Cannot bringup interface [chars], local 
port already in use 

Explanation    FCIP and iSCSI interface are trying to use the same local port, please use different ports

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_BAD_DATA_DIGEST_CRC: iSCSI ingress data digest error from 
initiator [chars] alias [chars] S_ID [hex] to D_ID [hex]

Explanation    ISCSI Ingress Data Digest CRC failed

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_DOWN_BATCH: [chars]: [dec] iSCSI sessions failed in 
last [chars], reason: [chars] 

Explanation    Number of iSCSI session down during the last time interval

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_DOWN: [chars]: iSCSI session down from initiator 
[chars] alias [chars] ip [chars] to target [chars], reason: [chars]

Explanation    ISCSI session goes down

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_UP: [chars]: iSCSI session up from initiator [chars] 
alias [chars] ip [chars] to target [chars]

Explanation    ISCSI session comes up and reaches Full-Feature phase

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_PORT_FAILOVER: [chars]: iSCSI initiator [chars] alias 
[chars] ip [chars] target [chars]. FC session failed over to port [chars]

Explanation    FC session for the iSCSI session failed over to newly active port

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SB_GET_TGT: iSCSI SB get [dec] targets, initiator [chars] 
alias [chars] ip [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_CREATE_FAILURE: [chars]: iSCSI Session initiator 
[chars] target [chars] create failed. [chars] 

Explanation    ISCSI Session Create failed

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_CREATE_REDIRECT: [chars]: iSCSI Session initiator 
[chars] target [chars] redirected to [chars]/[chars] 

Explanation    ISCSI Session Create redirected

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_REDIRECT_TIMEOUT: iSCSI Session initiator [chars] 
to [chars] redirected to [chars] timeout 

Explanation    ISCSI Session Redirect timeout

Recommended Action    No action is required.

Error Message     IPS-5-ISLB_CFS_SESSION_CLEARED: CFS Session Cleared 

Explanation    CFS Session Cleared by user

Recommended Action    No action is required.

Error Message     IPS-5-PORT_IPCFG_FAILED: Cannot configure IP address for interface 
[chars] 

Explanation    Cannot configure IPS port IP address

Recommended Action    No action is required.

Error Message     IPS-5-SB_MGR_CORE_FAILED: Ethernet Processing core [chars] failed due 
to [chars] 

Explanation    Ethernet Processing Core failed

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_ENTITY_ID_MISMATCH: [chars]: special frame profile ID 
mismatch 

Explanation    Special frame received and destination profile ID does not match local profile ID

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_FABRIC_WWN_MISMATCH: [chars]: special frame fabric wwn 
mismatch 

Explanation    Special frame received and source/destination fabric wwn does not match local destination/ source fabric wwn

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_IF_ADMIN_DOWN: [chars]: special frame received if down 

Explanation    Special frame received and interface is admin down

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_IF_NOT_ENABLED: [chars]: special frame not enabled 

Explanation    Special frame received and interface special frame configuration is disabled

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_INVALID_NONCE: [chars]: special frame response has 
invalid nonce for FCIP

Explanation    Special frame response has a different nonce than was originally sent in the special frame

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_NOT_RECV: [chars]: special frame was not received by 
passive-side FCIP 

Explanation    Special frame was not received by the passive-side of the FCIP TCP tunnel within given time period

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_RESP_MISMATCH: [chars]: special frame response has byte 
mismatch for FCIP

Explanation    Special frame response has a mismiatch in one of the bytes from what was sent from the FCIP special frame sender

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_RESP_NOT_RECV: [chars]: special frame response was not 
received by active-side FCIP

Explanation    Special frame response was not received by the active-side of the FCIP TCP tunnel within given time period

Recommended Action    No action is required.

IPS-7

Error Message     IPS-7-ISCSI_FCNS_QUERY_REQ: return [hex], wait [dec], VSAN [dec], 
Init: [chars] 

Explanation    ISCSI FCNS query

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_FCNS_QUERY_RESP: result [hex], [dec] targets, wait [dec], 
Init: [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_NEW_FCNS_QUERY_REQ: return [hex], VSANs [chars], Init: 
[chars] 

Explanation    ISCSI FCNS query

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_NEW_FCNS_QUERY_RESP: result [hex], [dec] entries, [dec] 
targets, [dec] total targets Init: [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-7-ISNS_SVR_ERR_RESPONSE: iSNS server returned following error 
code on iSNS request for interface [chars] : [dec]

Explanation    ISNS server returned an error for register/deregister request. For select error codes iSNS client would retry and re-register all target nodes corresponding to the interface

Recommended Action    No action is required.

IPV6 Messages

This section contains the IPV6 messages.

IPV6-2

Error Message    IPV6-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The IP Configuration Manager failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IPV6-3

Error Message     IPV6-3-FILE_WRITE_FAILED: Writing to file [chars] failed - error: 
[chars] 

Explanation    Writing to a file failed probably due to no space.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     IPV6-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

IPV6-4

Error Message     IPV6-4-DAD_FAILED_EVENT: Duplicate address detection failed for 
[chars] on [chars] 

Explanation    Duplicate address detection for IP address failed.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

IPV6-6

Error Message     IPV6-6-CONFIG_EVENT: IP Configuration Msg: [chars] 

Explanation    Configuration message that needs to be logged.

Recommended Action    No action is required.

Error Message     IPV6-6-INTERFACE_DELETED: The interface [chars] has been deleted 

Explanation    The specified interface has been deleted. The service will delete all the configuration on that interface.

Recommended Action    No action is required.

Error Message     IPV6-6-INTERFACE_EVENT: IP address [chars] [chars] on interface 
[chars] 

Explanation    The IP address [chars] has been successfully [chars] on the interface [chars].

Recommended Action    No action is required.

Error Message     IPV6-6-ROUTE_NOT_ACTIVE: The [chars] is not active 

Explanation    The specified route is successfully configured but currently is not active.

Recommended Action    Check that the route is correct and the outgoing interface is operationally up.

Error Message     IPV6-6-STARTING: IP configuration Manager started 

Explanation    The IP Configuration Manager service has successfully started.

Recommended Action    No action is required.

IP Messages

This section contains the IP messages.

IP-2

Error Message    IP-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The IP Configuration Manager failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IP-3

Error Message     IP-3-FILE_WRITE_FAILED: Writing to file [chars] failed - error: 
[chars] 

Explanation    Writing to a file failed probably due to no space.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     IP-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

IP-4

Error Message     IP-4-DAD_FAILED_EVENT: Duplicate address detected for [chars] on 
[chars] 

Explanation    Duplicate address detected for IP address.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

IP-6

Error Message     IP-6-CONFIG_EVENT: IP Configuration Msg: [chars] 

Explanation    Configuration message that needs to be logged.

Recommended Action    No action is required.

Error Message     IP-6-INTERFACE_DELETED: The interface [chars] has been deleted 

Explanation    The specified interface has been deleted. The service will delete all the configuration on that interface.

Recommended Action    No action is required.

Error Message     IP-6-INTERFACE_EVENT: IP address [chars] [chars] on interface [chars] 

Explanation    The IP address [chars] has been successfully [chars] on the interface [chars].

Recommended Action    No action is required.

Error Message     IP-6-ROUTE_NOT_ACTIVE: The [chars] is not active 

Explanation    The specified route is successfully configured but currently is not active.

Recommended Action    Check that the route is correct and the outgoing interface is operationally up.

Error Message     IP-6-STARTING: IP configuration Manager started 

Explanation    The IP Configuration Manager service has successfully started.

Recommended Action    No action is required.

ISAPI Messages

This section contains the ISAPI messages.

ISAPI-SLOT#-0

Error Message    ISAPI-SLOT#-0-INVISTA_EMERG: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-MSM_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-NSP_EMERG: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-SSM_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-SSN_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-1

Error Message     ISAPI-SLOT#-1-INVISTA_ALERT: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-MSM_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-NSP_ALERT: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-SSM_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-SSN_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-2

Error Message     ISAPI-SLOT#-2-INVISTA_CRIT: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-MSM_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-NSP_CRIT: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-SSM_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-SSN_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-3

Error Message     ISAPI-SLOT#-3-INVISTA_ERROR: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-MSM_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-NSP_ERROR: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-SSM_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-SSN_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-4

Error Message     ISAPI-SLOT#-4-INVISTA_WARN: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-MSM_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-NSP_WARN: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-SSM_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-SSN_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-5

Error Message     ISAPI-SLOT#-5-INVISTA_NOTICE: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-MSM_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-NSP_NOTICE: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-SSM_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-SSN_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-6

Error Message     ISAPI-SLOT#-6-INVISTA_INFO: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-MSM_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-NSP_INFO: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-SSM_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-SSN_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-7

Error Message     ISAPI-SLOT#-7-INVISTA_DEBUG: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-MSM_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-NSP_DEBUG: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-SSM_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-SSN_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISNS Messages

This section contains the ISNS messages.

ISNS-2

Error Message    ISNS-2-ISNS_CFS_OPERATION_FAILED: iSNS CFS [chars] failed 

Explanation    ISNS CFS operation failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     ISNS-2-ISNS_INIT: iSNS initialization of [chars] [chars] 

Explanation    ISNS initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IVR Messages

This section contains the IVR messages.

IVR-2

Error Message    IVR-2-AUTOLEARN_ACTION_FAIL: failure happens during constructing 
virtual dynamic pfcid table

Explanation    This can happen if failure happens during building, distributing or committing the virtual dynamic pfcid table

Recommended Action    Please 1. check the fabric connection or 2. check current virtual user-configured pfcid entries and internally assigned virtual fcid entries for possible conflict

Error Message     IVR-2-AUTOLEARN_FEATURE_NOT_SUPPORT: some switches:[chars] don't 
support autolearn 

Explanation    This can happen if some switches doesn't support the virtual pfcid autolearn feature

Recommended Action    Please upgrade the unsupported switches

Error Message     IVR-2-CFS_PEER_LOST_WITHIN_SESSION: CFS peer with switch wwn [chars] 
was lost in the middle of an active CFS session. Abort the CFS session and re-enter 
the configuration changes

Explanation    Due to port flaps, link outages, switch restart etc. a CFS peer switch of IVR was lost. The current configuration changes would not be applied to this peer until the peer merges with this switch. The CFS merge may fail if the configuration at the lost peer conflicts with the changes made in this session. Also, IVR auto topology could be out of sync. with this peer. It is recommended that the user abort this CFS session using ivr abort command and then re-enter the configuration changes.

Recommended Action    No action is required.

Error Message     IVR-2-DEVICE_FCID_REWRITE_FAILURE: Failure while programming FCID 
rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able 
to communicate with its peer devices, failure reason code: [hex]

Explanation    Failed to program FCID rewrite entries probably because the hardware ran out of FCID rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology

Recommended Action    Reduce the number of devices involved in IVR in the active IVR zoneset. Also, reduce the number of redundant transit VSANs, if any

Error Message     IVR-2-DEVICE_STATE_INCOMPATIBLE_WITH_NAT_MODE: State for device with 
port WWN [chars] could not be restored because it was incompatible with the current 
NAT mode([dec]). This probably happened because NAT mode was modified without 
completely deactivating the active IVR zoneset

Explanation    This probably happened because NAT mode was modified without completely deactivating the active IVR zoneset

Recommended Action    The switch needs to be rebooted

Error Message     IVR-2-DEVICE_VSAN_REWRITE_FAILURE: Failure while programming VSAN 
rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able 
to communicate with its peer devices

Explanation    Failed to program VSAN rewrite entries probably because the hardware ran out of VSAN rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology

Recommended Action    Reduce the number of domains involved in IVR by moving the members of active IVR zoneset to fewer switches. Also, reduce the number of redundant transit VSANs, if any

Error Message     IVR-2-INTEROP_MODE_2_OR_3_BF_FAILED: [chars] VSAN [dec] Virtual 
Domain [chars] 

Explanation    Build Fabric (BF) failed in VSAN [dec]. The BF was initiated in order to remove an unused virtual domain [dec] from the fcdomain list in that VSAN. The virtual domain still remains in the fcdomain list and hence it would not be available in that VSAN for assignment.

Recommended Action    Perform a manual build fabric using fcdomain's interface if you would like to remove the unused virtual domain(s) from the fcdomain list.

Error Message     IVR-2-INTEROP_MODE_2_OR_3_RDI_FAILED: VSAN [dec], requested domain 
[chars], received domain [chars] sWWN [chars]. Return Code [chars]

Explanation    Request Domain Identifier (RDI) command to allocate virtual domain [dec] failed in VSAN [dec]. Received another domain [chars] instead. IVR-members connected to third-party switch may not participate in IVR communications. It is likely that the domain requested in the RDI command is already in use.

Recommended Action    Reassign the domains so that the domain requested via RDI does not overlap with any existing domain in that VSAN.

Error Message     IVR-2-IVR_DISABLE_FAILED: Inter-VSAN Routing disable failed for 
reason: [chars] 

Explanation    Inter-VSAN Routing disable failed for reason: [chars]. Cleanup might not have completed

Recommended Action    Deactivate ivr zoneset and disable ivr again. If that fails, then the ivr process would terminate itself in 5 minutes

Error Message     IVR-2-IVZS_ACTIVATION_FAILED_RETRYING: Inter-VSAN zoneset activation 
failed in VSAN [dec] : [chars]. retrying after [dec] seconds

Explanation    Inter-VSAN zoneset activation failed in VSAN [dec] : [chars]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.

Recommended Action    No action is required.

Error Message     IVR-2-NO_LICENSE_SHUTDOWN: Inter-VSAN Routing is shutting down. 

Explanation    License required for continued IVR operation is not available. Hence IVR is shutting down

Recommended Action    Install appropriate license for IVR services and then enable IVR again.

Error Message     IVR-2-NO_LICENSE_WARNING: Inter-VSAN Routing would shutdown in [dec] 
seconds. 

Explanation    License required for continued IVR operation is not available. Unless the required license is installed IVR would shutdown in [dec] seconds. IVR configurations would be lost.

Recommended Action    Install appropriate license for IVR services to continute to operate uninterrupted within [dec] seconds

Error Message     IVR-2-PERSISTENT_VIRTUAL_FCID_CONFLICT_WITH_AUTOLEARN: Persistent 
virtual fcid and dynamic pfcid entries 

Explanation    This can happen if conflict happens during persistent virtual domain, or virtual fcid entry configuration.

Recommended Action    Please assign a non-conflict persistent virtual domain or fcid entry with current dynamic entries

Error Message     IVR-2-PERSISTENT_VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the 
configured persistent virtual domain/fcid could not be assigned

Explanation    This can happen if the virtual domain/fcid configured by the user is - a) Already in use (either by IVR or a real switch) b) Not allowed due to interop mode or allowed domain list

Recommended Action    Please make sure that the configured virtual domain/fcid is allowed and available for use

Error Message     IVR-2-VIRTUAL_DOMAIN_CONFLICT: In VSAN [dec] virtual domain [dec] 
from native VSAN [dec] conflicts with native VSAN [dec] for the same virtual domain

Explanation    Currently advertised virtual domain [dec] in VSAN [dec] is native to VSAN [dec]. This switch has learned of a device that is member of active IVR zone and has the same domain ID, but belongs to a different native VSAN. This device would not be advertised in that VSAN until the domain conflict is resolved.

Recommended Action    No action is required.

Error Message     IVR-2-VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the internally 
generated FCID conflicts with fcid assigned to WWN [chars]. Please configure fcid 
for WWN [chars] too

Explanation    This can happen if the virtual domain/fcid internally configured is already in use by another active device

Recommended Action    Please assign a different persistent virtual fcid by CLI command

IVR-3

Error Message     IVR-3-AAM_MODE_CANNOT_CHANGE: AAM mode cannot be changed. Might cause 
the fabric NAT mode inconsistency

Explanation    Could be caused by ivr NAT is not enable

Recommended Action    No action is required.

Error Message     IVR-3-ACL_ERROR: ACL API, [chars], failed with error [chars] 

Explanation    IVR invoked ACL API and received the error code. [chars] describes the API and [chars] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-ACL_PERMIT_ENTRY_ERROR: ACL permit entry update on interface 
[chars] failed for reason: [chars] 

Explanation    ACL could not program permit entries for IVR traffic. [chars] describes the interface named and [chars] describes the system error message from ACL. IVR traffic coming from the interface may be dropped.

Recommended Action    If the problem persists, please contact TAC, or your reseller for support.

Error Message     IVR-3-ACL_PLOGI_ENTRY_ERROR: PLOGI capture entry update in slot [dec] 
failed for reason: [chars] 

Explanation    ACL could not program IVR PLOGI could not be programmed. slot[dec] describes the line card slot number and [chars] describes the system error message. PLOGI and its response may be dropped because ivr process cannot capture those frames.

Recommended Action    No action is required.

Error Message     IVR-3-AFID_CONFLICT: [chars] 

Explanation    AFID configuration is different at different ivr-enabled switches in the same VSAN. Change AFID configuration (auto mode) or vsan topology configuration (user mode) to make it consistent

Recommended Action    No action is required.

Error Message     IVR-3-CFS_INVALID_PAYLOAD_RECEIVED: Inter-VSAN process received 
invalid payload from CFS 

Explanation    Inter-VSAN process received invalid payload from CFS.

Recommended Action    No action is required.

Error Message     IVR-3-CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_FAILED: [chars] 

Explanation    An error occurred while committing configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_PARTIALLY_FAILED: [chars] 

Explanation    An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_REJECTED: [chars] 

Explanation    Commit request received from remote switch is rejected. The reason for the failure: [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-DDAS_LOCK_TIMER_EXPIRED: IVR database lock is released, as 
device-alias commit/abort notification is not received in the expected time frame.

Explanation    When device-alias sends the validation request, IVR database is locked and a timer is started. For any reason, if device-alias commit/abort notification is not received within the expected time frame, the lock timer gets expired and the lock is released. If device-alias commmit notification is received after the lock is released, the changes are not applied and this could cause inconsistency between IVR and device-alias.

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_NOT_PREENT_IN_FB_DB_FICON: Device with port WWN [chars] 
could not be exported to VSANs [chars] because its native switch is not present 
in the current active fabric binding database of those VSANs.

Explanation    This happens if ficon is enabled on VSANs [chars] and native switch of device with port WWN [chars] is not present in the current active fabric binding database of those VSANs. This is a requirement for ficon compliance.

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_ON_WRONG_NATIVE_AFID_VSAN: Device with port WWN [chars] 
(FCID:[chars], native VSAN [dec] native AFID [dec]) may not be exported to other 
VSANs (for Inter-VSAN zoning) because it has come online in VSAN [dec] AFID [dec]

Explanation    Device has come online on a AFID/VSAN different from the configured native AFID/VSAN

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_ON_WRONG_NATIVE_VSAN: Device with port WWN [chars] 
(FCID:[chars], native VSAN [dec]) may not be exported to other VSANs (for 
Inter-VSAN zoning) because domain [hex] exists in VSAN [dec]

Explanation    Device has come online on a VSAN different from the configured native VSAN or the device does not satisfy unique domain criteria.

Recommended Action    No action is required.

Error Message     IVR-3-DM_ERROR: Domain Manager API, [chars], failed with error [hex] 

Explanation    IVR invoked DM API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-DOMAIN_DISALLOWED_IN_INTEROP: Device with port WWN [chars] and 
FCID [chars] may not be able to participate in Inter-VSAN zone since domain [dec] 
is disallowed in the interop mode for VSAN [dec]

Explanation    VSAN interop modes place restrictions on what domain ranges are allowed. This domain is out of the range allowed for this interop mode. See the Cisco MDS 9000 Family Configuration Guide for details on the domain range limitations.

Recommended Action    Change the domain of the switch to which this IVR zone member is connected to so that it is within the allowed domain list for the interop mode. The domain identifier can be statically assigned using fcdomain interface. You can also configure a range of domains allowed in a VSAN using the fcdomain's 'allowed-domains' interface.

Error Message     IVR-3-DOMAIN_UNAVAILABLE: Device with port WWN [chars] and FCID 
[chars] may not be able to participate in Inter-VSAN zone since domain [dec] is 
already assigned in VSAN [dec]

Explanation    Device with port WWN [chars] and FCID [dec] may not be able to participate in Inter-VSAN zone since domain [dec] is already assigned in VSAN [dec].

Recommended Action    No action is required.

Error Message     IVR-3-FC2_ERROR: FC2 API [chars] failed with error [hex] for [chars] 

Explanation    IVR invoked FC2 API for [chars] socket and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-FCID_NAT_MODE_CANNOT_CHANGE: IVR NAT mode cannot be changed. 
Might cause the fabric NAT mode inconsistency

Explanation    Could be caused by active zoneset, pending activation /deactivation or non-empty device list

Recommended Action    No action is required.

Error Message     IVR-3-FCID_REWRITE_REQUEST_TO_ACL_FAILED: fcid rewrite [chars] 
request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]). 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-INTERNAL_ERROR: Internal error: [chars] 

Explanation    IVR process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     IVR-3-INVALID_ZONE_MEMBER_PROP_INTEROP_MODE_2_3: unsupported 
member/zone properties in interop mode 2 or 3 [chars] 

Explanation    Inter-VSAN member properties incompatible with interop mode vsan

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_ACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] 
activation failed in VSAN [dec] 

Explanation    Inter-VSAN zoneset activation failed failed in VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_ACTIVATION_FAILED: Inter-VSAN zoneset [chars] activation 
failed 

Explanation    Inter-VSAN zoneset activation failed.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_DEACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] 
deactivation failed in VSAN [dec] 

Explanation    Inter-VSAN zoneset deactivation failed in VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_DEACTIVATION_FAILED: Inter-VSAN zoneset [chars] 
deactivation failed 

Explanation    Inter-VSAN zoneset deactivation failed.

Recommended Action    No action is required.

Error Message     IVR-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    An error occurred while activating merged configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MERGE_FAILED: reason is [chars] 

Explanation    An error occurred while merging configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MTS_ERROR: MTS message transmission failed with error [dec] 

Explanation    IVR process unsuccessfully tried to send a MTS message. MTS error number is specified in [dec].

Recommended Action    No action is required.

Error Message     IVR-3-NS_ERROR: FCNS API, [chars], failed with error [hex] 

Explanation    IVR invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] 
failed with error [hex] 

Explanation    IVR read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_ERROR: PSS operation [chars] returned error: [hex] 

Explanation    [chars] specifies the context where the failure occurred and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    IVR read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code.

Recommended Action    No action is required.

Error Message     IVR-3-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED: qos iod undrop request 
vsan [dec] did [chars] failed:[chars]. 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-RIB_ERROR: RIB API, [chars], failed with error [hex] 

Explanation    IVR invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-ROUTE_REQUEST_TO_ACL_FAILED: route [chars] request vsan [dec] 
domain [dec] failed:[chars]. 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-TOPOLOGY_COMPUTATION_FAILED: Inter-VSAN Topology computation 
has failed due to: [chars] 

Explanation    Inter-VSAN Topology has failed due to [chars]. Possible reasons are (a) Number of AFID/VSAN combination is more than te maximum supported value of 128, or (b) Number of ivr-enabled switches is more than the maximum supported value of 128

Recommended Action    No action is required.

Error Message     IVR-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is 
received 

Explanation    IVR process received unexpected MTS event. MTS opcode is specified in [dec].

Recommended Action    No action is required.

Error Message     IVR-3-UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-VSAN_SEGMENTED: [chars] 

Explanation    VSAN is segmented. VSAN is removed from the topology graph and hence no Inter-VSAN traffic can flow through this VSAN.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-ZS_POLICY_IS_DENY_NO_ACTIVE_ZS: Default zone behavior policy is 
deny on VSAN [dec] and there is no active zoneset

Explanation    Default zone behavior is deny and there is no active zoneset. Inter-VSAN zone members may not be able communicate in this VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-ZS_POLICY_IS_PERMIT_NO_FORCE: Default zone behavior policy is 
permit on VSAN [dec] and the force option is off

Explanation    Default zone behavior is permit and the force option is off. Inter-VSAN zoneset activation on this VSAN has failed.

Recommended Action    No action is required.

Error Message     IVR-3-ZS_POLICY_IS_PERMIT_ZS_DEACTIVATED: Default zone behavior 
policy is permit on VSAN [dec] and regular zoneset deactivated

Explanation    Default zone behavior is permit and regular zoneset is deactivated. Inter-VSAN zone members may not be able to communicate.

Recommended Action    No action is required.

IVR-4

Error Message     IVR-4-AUTO_TOPOLOGY_UPDATE_DISCARDED: [chars] 

Explanation    Received auto topology update is discarded due to conflicts

Recommended Action    No action is required.

Error Message     IVR-4-FCID_REWRITE_REQUEST_TO_ACL_FAILED_AND_RETRYING: fcid rewrite 
[chars] request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]). Retrying 
the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-PERSISTENT_VIRTUAL_DOMAIN_MERGE_CONFLICT: [chars] 

Explanation    Merge failed due to conflict in the persistent virtual domain configuration

Recommended Action    No action is required.

Error Message     IVR-4-PERSISTENT_VIRTUAL_FCID_MERGE_CONFLICT: [chars] 

Explanation    Merge failed due to conflict in the persistent virtual fcid configuration

Recommended Action    No action is required.

Error Message     IVR-4-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED_AND_RETRYING: qos iod 
undrop request vsan [dec] did [chars] failed:[chars]. Retrying the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-ROUTE_REQUEST_TO_ACL_FAILED_AND_RETRYING: route [chars] 
request vsan [dec] domain [dec] failed:[chars]. Retrying the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-UNKNOWN_NATIVE_VSAN: Unknown native VSAN for the virtual domain 
[dec] in VSAN [dec] local native VSAN for the same virtual domain is [dec]

Explanation    Could not determine native VSAN of the currently advertised virtual domain [dec] in VSAN [dec]. This switch has learned of a device that is member of active IVR zone has the same domain ID, and belongs to native VSAN [dec]. This device would not be advertised in that VSAN until the native VSAN information is resolved.

Recommended Action    No action is required.

IVR-5

Error Message     IVR-5-AAM_MODE_DEREGISTERED_FAILED: Abstract ACL Manager (AAM) mode 
deregister failed 

Explanation    Abstract ACL Manager (AAM) mode deregister failed

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_DEREGISTERED: Abstract ACL Manager (AAM) mode has been 
deregistered 

Explanation    Abstract ACL Manager (AAM) mode has been deregistered

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_REGISTERED_FAILED: Abstract ACL Manager (AAM) register 
failed 

Explanation    Abstract ACL Manager (AAM) register failed

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_REGISTERED: Abstract ACL Manager (AAM) mode has been 
registered 

Explanation    Abstract ACL Manager (AAM) mode has been registered

Recommended Action    No action is required.

Error Message     IVR-5-FCID_NAT_MODE_ACTIVATED: FCID network address translation (NAT) 
mode has been activated 

Explanation    FCID network address translation (NAT) mode has been activated

Recommended Action    No action is required.

Error Message     IVR-5-FCID_NAT_MODE_DEACTIVATED: FCID network address translation 
(NAT) mode has been deactivated 

Explanation    FCID network address translation (NAT) mode has been deactivated

Recommended Action    No action is required.

Error Message     IVR-5-IVR_ASSERTION_FAILED: Unexpected assertion failure in File 
[chars] at Line [dec] 

Explanation    An assertion failed in IVR code

Recommended Action    No action is required.

Error Message     IVR-5-IVZS_ACTIVATION_RETRYING: Inter-VSAN zoneset activation did not 
go through because of [chars], retrying in VSAN [dec] after [dec] seconds

Explanation    Inter-VSAN zoneset activation failed because of [chars] in VSAN [dec]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.

Recommended Action    No action is required.

Error Message     IVR-5-IVZS_WAITING_FOR_LOWEST_SWWN: Waiting for lowest switch WWN 
Inter-VSAN enabled switch in VSAN [dec] 

Explanation    Only lowest switch WWN Inter-VSAN enabled switch adds the Inter-VSAN zones to the regular active zoneset in a VSAN. This local switch is not the lowest sWWN switch in VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_ACTIVATED_VSAN: Inter-VSAN zoneset [chars] activated in 
VSAN [dec] 

Explanation    Inter-VSAN zoneset activated in VSAN[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_ACTIVATED: Inter-VSAN zoneset [chars] activated 

Explanation    Inter-VSAN zoneset activated[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_CLEANUP_DONE_BY_TIMER: Inter-VSAN clean-up is not done 
after waiting for 5 minutes 

Explanation    Inter-VSAN related configuration might not be cleaned up before the ivr process is terminated

Recommended Action    If the problem persists, you may have to reboot your switch to clean up the old IVR configuration

Error Message     IVR-5-IVZ_CLEANUP_DONE: Inter-VSAN clean-up is done 

Explanation    Inter-VSAN related configuration is cleaned up before exiting.

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_DEACTIVATED_VSAN: Inter-VSAN zoneset [chars] deactivated in 
VSAN [dec] 

Explanation    Inter-VSAN zoneset deactivated in VSAN[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_DEACTIVATED: Inter-VSAN zoneset [chars] deactivated 

Explanation    Inter-VSAN zoneset deactivated[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_PARTIALLY_ACTIVATED: Inter-VSAN zoneset [chars] partially 
activated 

Explanation    Inter-VSAN zoneset activated[dec].

Recommended Action    Check if it is successful in all VSANs by doing show IVR zoneset status.

Error Message     IVR-5-IVZ_PARTIALLY_DEACTIVATED: Inter-VSAN zoneset [chars] partially 
deactivated 

Explanation    Inter-VSAN zoneset deactivated[dec].

Recommended Action    Check if it is successful in all VSANs by doing show IVR zoneset status.

Error Message     IVR-5-LICENSE_CHECKIN_FAILED: Failed to checkin [chars] license: 
Err=[chars] 

Explanation    Failed to checkin [chars] license

Recommended Action    No action is required.

Error Message     IVR-5-SERVICE_GROUP_ACTIVATED: Inter-VSAN Service Group has been 
activated 

Explanation    Inter-VSAN Service Group has been activated.

Recommended Action    No action is required.

Error Message     IVR-5-SERVICE_GROUP_DEACTIVATED: Inter-VSAN Service Group has been 
deactivated 

Explanation    Inter-VSAN Service Group has been deactivated.

Recommended Action    No action is required.

Error Message     IVR-5-VSAN_NO_LONGER_SEGMENTED: [chars] 

Explanation    VSAN is no longer segmented. VSAN is added back to the topology graph and hence Inter-VSAN traffic can now flow through this VSAN.

Recommended Action    No action is required.

Error Message     IVR-5-VSAN_TOPOLOGY_ACTIVATED: Inter-VSAN Topology has been activated 

Explanation    Inter-VSAN Topology has been activated.

Recommended Action    No action is required.

IVR-6

Error Message     IVR-6-DRAV_ASYNC_DOMAIN_RELEASE: [chars] 

Explanation    DRAV FSM has unconditionally released a domain due to conflict after a fabric merge. The details are in [chars]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_CRITICAL_RETRY_EXCEED: [chars] 

Explanation    DRAV FSM frames are attempted to be resent. The details are in [chars]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_DOMAIN_ALLOC: Virtual domain [dec] for Native AFID: [dec] 
Native VSAN [dec] 

Explanation    A virtual domain indicated by [dec] has been reserved for a device with native AFID [dec] and native VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_DOMAIN_RELEASE: Virtual domain [dec] for Native AFID: 
[dec] Native VSAN [dec] 

Explanation    A virtual domain indicated by [dec] has been released used by devices with native AFID [dec] and native VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_TOPO_UPDATE: [chars] 

Explanation    DRAV FSM Topology has been updated as indicated by [chars]

Recommended Action    No action is required.

Error Message     IVR-6-LICENSE_VALID: A valid license for Inter-VSAN Routing has been 
obtained 

Explanation    A valid license for Inter-VSAN Routing has been obtained

Recommended Action    No action is required.

IVR-7

Error Message     IVR-7-CFS_REQ_RCVD: [chars] 

Explanation    CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.

Recommended Action    No action is required.

Error Message     IVR-7-CFS_RESP_SENT: [chars] 

Explanation    CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message

Recommended Action    No action is required.

L2FMC Messages

This section contains the L2FMC messages.

L2FMC-SLOT#-0

Error Message    L2FMC-SLOT#-0-L2FMC_CLI_INIT_FAILED: CLI library initialization 
failed! 

Explanation    L2FMC failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-0-L2FMC_TIMER_INIT_FAILED: Timer subsystem 
initialization failed! 

Explanation    L2FMC failed to initialize timer library. This is a fatal error.

Recommended Action    No action is required.

L2FMC-SLOT#-2

Error Message     L2FMC-SLOT#-2-L2FMC_MEM_ALLOC: Memory allocation failed. [chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-2-L2FMC_VLAN_NOT_FOUND: VLAN [dec] not found in L2FMC 
database! 

Explanation    L2FMC failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.

Recommended Action    No action is required.

L2FMC-SLOT#-5

Error Message     L2FMC-SLOT#-5-L2FMC_GLBL_AGE_CONFIG_FAIL: Global age value 
configuration to [dec] seconds failed! 

Explanation    L2FMC failed to configure global default age to [dec] seconds.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-5-L2FMC_VLAN_AGE_CONFIG_FAIL: VLAN Age configuration to 
[dec] seconds failed! 

Explanation    L2FMC failed to configure age for VLAN [dec] to [dec] seconds.

Recommended Action    No action is required.

L2FMC-SLOT#-6

Error Message     L2FMC-SLOT#-6-L2FMC_GLBL_AGE_CONFIGURED: Global age value configured 
to [dec] seconds. 

Explanation    L2FMC has successfully configured global default age to [dec] seconds.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_INITIALIZED: Internal state created [chars] 

Explanation    L2FMC has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_CREATED: VDC [dec] created 

Explanation    Request to create VDC [dec] in L2FMC was successful.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_REMOVED: VDC [dec] Removed 

Explanation    L2FMC has successfully removed VDC [dec] from its databases.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_VLAN_CREATED: VLAN [dec] created 

Explanation    L2FMC has added VLAN [dec].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC 
[dec] 

Explanation    L2FMC has successfully removed VLAN [dec] from VDC [dec].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VLAN_AGE_CONFIGURED: Age configured for VLAN 
[dec] to [dec] seconds. 

Explanation    L2FMC has successfully configured age for VLAN [dec] to [dec] seconds.

Recommended Action    No action is required.

L2FM Messages

This section contains the L2FM messages.

L2FM-0

Error Message    L2FM-0-L2FM_CLI_INITIALIZATION_FAILED: CLI library initialization 
failed! 

Explanation    Failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2FM-0-L2FM_VDC_GWMAC_GET_FAILED: Failed to get gwmac for VDC 

Explanation    Failed to get gwmac for VDC.

Recommended Action    No action is required.

Error Message     L2FM-0-L2FM_WRITE_TO_PSS_FAILED_IN_PREVIOUS_INCARNATION: PSS Write 
Failed in pervious incarnation. Stateful restart not possible 

Explanation    PSS Write Failed in pervious incarnation. Stateful restart not possible

Recommended Action    No action is required.

L2FM-1

Error Message     L2FM-1-L2FM_SMAC_DUP_FOUND: Duplicate static mac found in secondary 
vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars] 

Explanation    Duplicate static mac found in secondary vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars]

Recommended Action    No action is required.

Error Message     L2FM-1-L2FM_WRITE_TO_PSS_FAILED: Failed to write to PSS err [chars] 

Explanation    Failed to write to PSS err [chars]

Recommended Action    No action is required.

L2FM-2

Error Message     L2FM-2-L2FM_AGING_TIME_SET_FAILED: Failed to set age time [dec] for 
vlan [dec] 

Explanation    Failed to set age time [dec] for vlan [dec].

Recommended Action    No action is required.

Error Message     L2FM-2-L2FM_GLBL_AGING_TIME_SET_FAILED: Failed to set global age time 
[dec] 

Explanation    Failed to set global age time [dec]

Recommended Action    No action is required.

Error Message     L2FM-2-L2FM_SMAC_INS_FAILED: Failed to insert static mac for 
VLAN:[dec] MAC:[chars] IfIndex:[hex] Slot:[dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

L2FM-6

Error Message     L2FM-6-L2FM_MTS_SEND_FAILED: Failed to send MTS message errno [hex] 
opcode [dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

L2MCAST Messages

This section contains the L2MCAST messages.

L2MCAST-SLOT#-0

Error Message    L2MCAST-SLOT#-0-L2MCAST_CLI_INIT_FAILED: CLI library initialization 
failed! 

Explanation    L2MCAST failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-0-L2MCAST_TIMER_INIT_FAILED: Timer subsystem 
initialization failed! 

Explanation    L2MCAST failed to initialize timer library. This is a fatal error.

Recommended Action    No action is required.

L2MCAST-SLOT#-2

Error Message     L2MCAST-SLOT#-2-L2MCAST_VLAN_NOT_FOUND: VLAN [dec] not found in 
L2MCAST database! 

Explanation    L2MCAST failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-2-L2MCAST: Memory allocation failed. [chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No action is required.

L2MCAST-SLOT#-6

Error Message     L2MCAST-SLOT#-6-L2MCAST_HW_INSTALL_FAIL: Hw install failed for vlan 
[dec] ([dec], [chars], [chars]) entry! 

Explanation    L2MCAST failed to insert bd, g, s entry in hardware. Igmp snooping may not be effective on vlan for that group and source

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_INITIALIZED: Internal state created [chars] 

Explanation    L2MCAST has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_CREATED: VDC [dec] created 

Explanation    Request to create VDC [dec] in L2MCAST was successful.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_REMOVED: VDC [dec] Removed 

Explanation    L2MCAST has successfully removed VDC [dec] from its databases.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_CREATED: VLAN [dec] created 

Explanation    L2MCAST has added VLAN [dec].

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC 
[dec] 

Explanation    L2MCAST has successfully removed VLAN [dec] from VDC [dec].

Recommended Action    No action is required.

LACP Messages

This section contains the LACP messages.

LACP-3

Error Message    LACP-3-GENERAL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     LACP-3-LACP_MEM_PC_MISCFG: LACP misconfiguration detected on [chars]: 
([chars] [dec]-[dec][chars] [dec]-[dec]) 

Explanation    There was an LACP misconfiguration

Recommended Action    No action is required.

Error Message     LACP-3-LACP_MISCFG: LACP misconfiguration detected on [chars]: 
([chars]) 

Explanation    There was an LACP misconfiguration

Recommended Action    No action is required.

Error Message     LACP-3-LACP_SUSPEND_HALF_DUPLEX_PORT: Port [chars] is in half duplex 
mode. suspend port 

Explanation    LACP is not supported in half duplex mode. Suspend port

Recommended Action    No action is required.

Error Message     LACP-3-LACP_UPGRADE_READY_FAILED: Upgrade ready was returned failure. 

Explanation    Upgrade ready event was returned failure since one of the ports in port channels were found to be in intermediate state.

Recommended Action    No action is required.

Error Message     LACP-3-PACKET_TRANSMIT_ERR: [chars]: Could not send LACP packet 
err=[dec] 

Explanation    There was an error in sending LACP packet

Recommended Action    No action is required.

Error Message     LACP-3-SYN_COLL_DIS_EN: [chars] [[chars]]: SYNC, COLLECT and 
DISTRIBUTE flags enabled too early by partner 

Explanation    Potential interop issue. Partner system seems to have enabled sync as well collecting or distributing flags too early even before actor has selected an aggregator

Recommended Action    No action is required.

Error Message     LACP-3-SYSTEM_MAC_ERR: [chars]: Could not get system mac[[chars]] 

Explanation    There was an error in acquiring system mac from VDC Mgr

Recommended Action    No action is required.

LACP-5

Error Message     LACP-5-LACP_DISABLED: LACP Disabled 

Explanation    LACP Service Disabled

Recommended Action    No action is required.

Error Message     LACP-5-LACP_ENABLED: LACP Enabled 

Explanation    LACP Service Enabled

Recommended Action    No action is required.

Error Message     LACP-5-LACP_REMOTE_NOTIFY_SUCCESS: Remote notify event. 

Explanation    Remote notify event was returned success.

Recommended Action    No action is required.

Error Message     LACP-5-LACP_SUSPEND_INDIVIDUAL: LACP port [chars] of port-channel 
[chars] not receiving any LACP BPDUs suspending (individual) port 

Explanation    LACP suspend individual ports

Recommended Action    No action is required.

Error Message     LACP-5-LACP_UPGRADE_READY_SUCCESS: Upgrade ready was returned 
success. 

Explanation    Upgrade ready event was returned success since all ports in port channels were found in steady state.

Recommended Action    No action is required.

Error Message     LACP-5-PORT_PRIORITY_CHANGED: [chars]: LACP port priority changed 
from [dec] to [dec] 

Explanation    LACP port priority has been changed

Recommended Action    No action is required.

Error Message     LACP-5-SYSTEM_PRIORITY_CHANGED: LACP system priority changed from 
[hex] to [hex] 

Explanation    LACP system priority has been changed

Recommended Action    No action is required.

LC-FCFWD Messages

This section contains the LC-FCFWD messages.

LC-FCFWD-3

Error Message    LC-FCFWD-3-ERROR: [chars] 

Explanation    Lc_fcfwd encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC-SPAN Messages

This section contains the LC-SPAN messages.

LC-SPAN-3

Error Message    LC-SPAN-3-ERROR: [chars] 

Explanation    Lc_span_mgr encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC_CFG Messages

This section contains the L2_CFG messages.

LC_CFG-SLOT#-2

Error Message    LC_CFG-SLOT#-2-LC2_CPU_ERRORS: [chars], Total IC [dec], DC [dec], Tag 
[dec], MBit [dec], SBit [dec], I30 [dec] 

Explanation    LC CPU Cache errors.

Recommended Action    No action is required.

Error Message     LC_CFG-SLOT#-2-LC_CFG_ABORT: registration aborted with code [dec] 

Explanation    Process lc_cfg_mgr aborted registration

Recommended Action    No action is required.

Error Message     LC_CFG-SLOT#-2-LC_CFG_EXITED: exited with code [dec] 

Explanation    Process lc_cfg_mgr exited

Recommended Action    No action is required.

LC_PORT_CHANNEL Messages

This section contains the LC_PORT_CHANNEL messages.

LC_PORT_CHANNEL-SLOT#-0

Error Message    LC_PORT_CHANNEL-SLOT#-0-HW_FAILURE: fatal error in configureing 
[chars]: [chars] 

Explanation    Fatal hardware error in port-channel configuration

Recommended Action    Reset the module

Error Message     LC_PORT_CHANNEL-SLOT#-0-IDX_FULL: D_IDX table full (current [dec], 
new [dec], total [dec]) 

Explanation    Programming error in port-channel configuration

Recommended Action    Reset the module

LC_PORT_CHANNEL-SLOT#-3

Error Message     LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_IDXMAP_FAILURE: could not 
lookup port index for interface [chars] 

Explanation    Could not look up port index

Recommended Action    No action is required.

LC_PORT_MGR Messages

This section contains the LC_PORT_MGR messages.

LC_PORT_MGR-SLOT#-2

Error Message    LC_PORT_MGR-SLOT#-2-LC_MTS_ERROR: An MTS error has occurred in 
([chars]) with the following conditions: opc=[dec] ssap=[hex] dsap=[hex] 
syserr=[hex] 

Explanation    This is a software error in message communication between two applications.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC_RDL Messages

This section contains the LC_RDL messages.

LC_RDL-3

Error Message    LC_RDL-3-SYSLOG_ALLOC_FAIL: : [chars] 

Explanation    RDL malloc failed : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_CONTEXT_ERR: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_ERR: : [chars] 

Explanation    RDL syslog errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_EXIT: : [chars] 

Explanation    RDL exiting on errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_INIT_FAIL: : [chars] [chars] 

Explanation    RDL Init Failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_MTS_ERR: : [chars] 

Explanation    RDL MTS errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_MTS_REG_FAILED: : [dec] [dec] 

Explanation    RDL context error: [dec] [dec]

Recommended Action    No action is required.

LC_RDL-6

Error Message     LC_RDL-6-SYSLOG_DEBUG_1: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_DEBUG_2: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_INFO: : [chars] 

Explanation    RDL Debug logs: [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_RESP_RCVD: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec]

Recommended Action    No action is required.

LIBBASE_SVC Messages

This section contains the LIBBASE_SVC messages.

LIBBASE_SVC-2

Error Message    LIBBASE_SVC-2-IT_NEXUS_MAX_INTERFACE_LIMIT_REACHED: [chars] cannot be 
bound for site [chars], as the interfaces reached the maximum flow limit

Explanation    IT Load Balancing failed

Recommended Action    No action is required.

LIBBASE_SVC-5

Error Message     LIBBASE_SVC-5-FLOW_NOT_ALLOWED: Flow [chars] <-> [chars] disallowed 
in multiple clusters 

Explanation    Flow creation failed

Recommended Action    No action is required.

Error Message     LIBBASE_SVC-5-IT_NEXUS_FAILURE: [chars]. [chars] bind failure. 
Reason: [chars]: [hex] 

Explanation    IT Nexus bind failed

Recommended Action    No action is required.

Error Message     LIBBASE_SVC-5-IT_NEXUS_OPTIMUM_INTERFACE_LIMIT_REACHED: Interface 
[chars] exceeded the optimum flow limit 

Explanation    Iterface Flow Limit

Recommended Action    No action is required.

LIBGD Messages

This section contains the LIBGD messages.

LIBGD-2

Error Message    LIBGD-2-GD_ACCESS_FAILED: Guardian Failed to access reg for [chars] 

Explanation    Guardian Access failed

Recommended Action    No action is required.

Error Message     LIBGD-2-GD_CATASTROPHIC: Guardian catastrophic failure: [chars] 

Explanation    Guardian catastrophic error

Recommended Action    No action is required.

Error Message     LIBGD-2-GD_INTR: Guardian Interrupt occurred: [chars] 

Explanation    Interrupt occurred on the Guardian

Recommended Action    No action is required.

Error Message     LIBGD-2-SHUTDOWN: Guardian software process exiting: [chars] 

Explanation    Guardian shutting down

Recommended Action    No action is required.

LIBGD-3

Error Message     LIBGD-3-EN_DATA_FAILED: Guardian enable port failed for inst:[dec] 
port:[dec] 

Explanation    Guardian Enable port failed for the guardian

Recommended Action    No action is required.

LIBGD-5

Error Message     LIBGD-5-STARTING: Guardian process starting 

Explanation    Guardian process is being started

Recommended Action    No action is required.

LIBGD-6

Error Message     LIBGD-6-DIS_DATA: Guardian disable port done for inst:[dec] 
port:[dec] 

Explanation    Disabled port successfully for guardian

Recommended Action    No action is required.

Error Message     LIBGD-6-EN_PORT: Guardian enable port done for inst:[dec] port:[dec] 

Explanation    Enabled port for the Guardian

Recommended Action    No action is required.

Error Message     LIBGD-6-HW_INIT: GuardianHW initialization has been done for inst: 
[dec] port: [dec] 

Explanation    Guardian HW initializtion has been called[dec]

Recommended Action    No action is required.

LICMGR Messages

This section contains the LICMGR messages.

LICMGR-2

Error Message    LICMGR-2-LOG_LIC_EXIT: License manager exiting: [chars] 

Explanation    License manager exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_GRACE_EXPIRED: Grace period expired for feature 
[chars]. 

Explanation    Unlicensed feature [chars] has exceeded it's grace time period. Applications using will be shut down immediately.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-2-LOG_LIC_INVALID_SERVER_LINE: License file [chars] contains 
invalid SERVER line. Contact TAC 

Explanation    Invalid SERVER line in license file.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_N1K_DEFAULT_LICENSE_EXPIRED: Default Evaluation 
license expired for feature [chars]. 

Explanation    Default Evaluation license expired for feature [chars].

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-2-LOG_LIC_NVRAM_DISABLED: Licensing NVRAM is not available. 
Grace period will be disabled: [chars]

Explanation    The Supervisor NVRAM block may have a hardware problem and may need to be replaced

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_USAGE: Feature [chars] is using [dec] licenses, only 
[dec] licenses are installed. Please make sure enough licenses are installed for 
the VEMs

Explanation    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Recommended Action    Licensing

Error Message     LICMGR-2-LOG_LIC_VENDOR_DOWN: License file contains invalid SERVER 
line. Vendor daemon down 

Explanation    Vendor daemon is down

Recommended Action    Licensing

LICMGR-3

Error Message     LICMGR-3-LOG_LICAPP_NO_LIC: Application [chars] running without 
[chars] license, shut down in [dec] days.

Explanation    Application [chars1] has not been licensed. The application will work for a grace period of [dec] days after which it will be shut down unless a license file for feature [chars2] is installed.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_CHECKOUT_FAIL_BAD_CLOCK: License checkout failed for 
feature [chars]([chars]) because system clock has been set back. Please set the 
clock to the correct value.

Explanation    License checkout failed for feature [chars]([chars]) because system clock has been set back. Please set the clock to the correct value.

Recommended Action    No action is required.

Error Message     LICMGR-3-LOG_LIC_FILE_MISSING: License file(s) missing for feature 
[chars]. 

Explanation    One or more license files for feature [chars] are missing and must be reinstalled.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_INVALID_HOSTID: Invalid license hostid VDH=[chars] 
for feature [chars]. 

Explanation    Feature [chars2] has a license with an invalid license hostid VDH=[chars1]. This can occur if a supervisor card with licensed features for one switch is installed on another switch.

Recommended Action    No action is required.

Error Message     LICMGR-3-LOG_LIC_LICENSE_EXPIRED: Evaluation license expired for 
feature [chars]. 

Explanation    The named feature has exceeded it's evaluation time period. Applications using the license will be shut down after a grace period.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_MESSAGE_ERROR: could not handle message: [chars] of 
type [dec] from addr [dec]:[dec]. 

Explanation    Could not handle a IPC message [chars] of type [dec1] sent by a component running on node [dec2] with sap [dec3].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-3-LOG_LIC_NO_LIC: No license(s) present for feature [chars]. 
Application(s) shut down in [dec] days.

Explanation    Feature [chars] has not been licensed. The feature will work for a grace period of [dec] days after which application(s) using the feature will be shut down.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_SERVER_DOWN: License Server Down [dec] 

Explanation    A connection to the license server was lost.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-3-LOG_LIC_SPROM_LIC: Feature [chars] issued [dec] licenses 
without a valid license file. 

Explanation    Feature [chars] has been licensed [dec] times without a valid license file. This means one or more license files are missing for feature [chars] and must be reinstalled.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_TOO_MANY_LIC: Only [dec] licenses are supported for 
[chars] feature, where as [dec] licenses are installed.

Explanation    More licenses are installed than allowed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LICMGR-4

Error Message     LICMGR-4-LOG_LICAPP_EXPIRY_WARNING: Application [chars] evaluation 
license [chars] expiry in [dec] days. 

Explanation    Application [chars1] will exceed it's evaluation time period in [dec] days and will be shut down after a grace period unless a permanent license for feature [chars2] is installed.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_LICENSE_EXPIRY_WARNING: Evaluation license for 
feature [chars] will expire in [dec] days. 

Explanation    Feature [chars] will exceed it's evaluation time period in [dec] days and will be shut down.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_N1K_DEFAULT_EXPIRY_WARNING: Default Evaluation 
license for feature [chars] will expire in [dec] days. Please make sure to install 
enough permanent licenses so as to avoid any disruption in traffic.

Explanation    Feature [chars] will exceed it's default evaluation time period in [dec] days. Please make sure to install enough permanent licenses so as to avoid any disruption in traffic.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_N1K_EXPIRY_WARNING: Evaluation license for feature 
[chars] will expire in [dec] days. Please make sure to install enough permanent 
licenses so as to avoid any disruption in traffic.

Explanation    Feature [chars] will exceed it's evaluation time period in [dec] days. Please make sure to install enough permanent licenses so as to avoid any disruption in traffic.

Recommended Action    Please install the license file to continue using the feature.

LICMGR-6

Error Message     LICMGR-6-LOG_CHECKPOINT_CREATED: created during license expiry. 

Explanation    When a license expires, auto checkpoint is created to prevent configuration loss.

Recommended Action    Rollback can be done to the created checkpoint when a new license is installed.

Error Message     LICMGR-6-LOG_LIC_FEATURE_CLEARED: Cleared [dec] license(s) for 
feature [chars]. 

Explanation    Uninstalled [dec] license(s) for feature [chars].

Recommended Action    Use the 'show license usage' command to verify this license feature removal.

Error Message     LICMGR-6-LOG_LIC_FEATURE_INSTALLED: Installed [dec] license(s) for 
feature [chars]. 

Explanation    Installed [dec] license(s) for feature [chars].

Recommended Action    Use the 'show license usage' command to verify this license feature installation.

Error Message     LICMGR-6-LOG_LIC_LICENSE_CLEARED_ALL: Cleared all licenses. 

Explanation    Cleared all license files.

Recommended Action    No action is required.

Error Message     LICMGR-6-LOG_LIC_LICENSE_CLEARED: Cleared license file [chars]. 

Explanation    Uninstalled the named license file.

Recommended Action    Use the 'show license' command to verify this license removal.

Error Message     LICMGR-6-LOG_LIC_LICENSE_INSTALLED: Installed license file [chars]. 

Explanation    Installed the named license file.

Recommended Action    Use the 'show license' command to verify this license installation.

LLDP Messages

This section contains the LLDP messages.

LLDP-3

Error Message    LLDP-3-DETECT_MULTIPLE_PEERS: Multiple peers detected on [chars] 

Explanation    Multiple peers detected on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-INVALID_DCBXP_RECEIVED: Received an invalid DCBXP on [chars] 

Explanation    Received an invalid DCBXP on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-INVALID_LLDP_RECEIVED: Received an invalid LLDP on [chars] 

Explanation    Received an invalid LLDP on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-LLDP_INTERNAL_ERROR: LLDP internal error: [chars] 

Explanation    Internal error is encountered

Recommended Action    No action is required.

LLDP-5

Error Message     LLDP-5-LLDP_DISABLED: LLDP Disabled 

Explanation    LLDP Service Disabled

Recommended Action    No action is required.

Error Message     LLDP-5-LLDP_ENABLED: LLDP Enabled 

Explanation    LLDP Service Enabled

Recommended Action    No action is required.

Error Message     LLDP-5-SERVER_ADDED: Server with Chassis ID [chars] Port ID [chars] 
management address [chars] discovered on local port [chars] in vlan [dec] 

Explanation    A new peer is discovered

Recommended Action    No action is required.

Error Message     LLDP-5-SERVER_REMOVED: Server with Chassis ID [chars] Port ID [chars] 
on local port [chars] has been removed 

Explanation    A peer is removed

Recommended Action    No action is required.

LLDP-6

Error Message     LLDP-6-DETECT_REMOTE_CHANGE: Remote change detected on [chars] 

Explanation    Remote change detected on an interface

Recommended Action    No action is required.

Error Message     LLDP-6-DETECT_REMOTE_DCBXP_CHANGE: Remote DCBXP change detected on 
[chars] 

Explanation    Remote DCBXP change detected on an interface

Recommended Action    No action is required.

MAC Messages

This section contains the MAC messages.

MAC-SLOT#-2

Error Message    MAC-SLOT#-2-MAC_INFO: [chars] 

Explanation    MAC Informational message

Recommended Action    No action is required.

MCAST Messages

This section contains the MCAST messages.

MCAST-2

Error Message    MCAST-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    Mcast is shutting down

Recommended Action    The action depends on the situation. The multicast process can shut down gracefully because of a system restart (in which case no action needs to take place) or because of a failure. The message associated with the syslog should be self explanatory to understand the reason for the shutdown. If the process is able to restart properly, there is no immediate harm for the system stability and the suggested action is to report the syslog event together with an explanation of the operations most recently performed on the system.

MCAST-4

Error Message     MCAST-4-ERROR: [chars] 

Explanation    Mcast encountered a generic error

Recommended Action    No action is required.

MCAST-5

Error Message     MCAST-5-BAD_MSG: Received bad message: [chars] 

Explanation    Mcast has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     MCAST-5-START: Process has been started 

Explanation    Mcast has been started

Recommended Action    No action is required.

MCECTEST Messages

This section contains the MCECTEST messages.

MCECTEST-3

Error Message    MCECTEST-3-ASSERTION_FAILED: [chars] 

Explanation    MCECTEST has hit an assert condition at file [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-INIT_FAIL: [chars] 

Explanation    MCECTEST Initialization failed. due to [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-INTERNAL_ERR: [chars] 

Explanation    MCECTEST encountered an internal error due to [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-MTS_ERR: [chars] 

Explanation    MCECTEST encountered an MTS error due to [chars]

Recommended Action    No action is required.

MCECTEST-5

Error Message     MCECTEST-5-MCECTEST_DISABLED: MCECTEST Disabled 

Explanation    MCECTEST Service Disabled

Recommended Action    No action is required.

Error Message     MCECTEST-5-MCECTEST_ENABLED: MCECTEST Enabled 

Explanation    MCECTEST Service enabled

Recommended Action    No action is required.

MCECTEST-6

Error Message     MCECTEST-6-INTERNAL_INFO: [chars] 

Explanation    MCECTEST got an internal info [chars]

Recommended Action    No action is required.

MCM Messages

This section contains the MCM messages.

MCM-5

Error Message    MCM-5-MCM_SDB_UPDATE_FAILED: sdb update failed with ret_val [dec] 

Explanation    SDB updated failed for MCM

Recommended Action    No action is required.

MFDM Messages

This section contains the MFDM messages.

MFDM-2

Error Message    MFDM-2-INTERNAL_ERROR: MFDM-[chars] Internal error : show system 
internal mfdm errors for more information

Explanation    MFDM PD hit a internal error. show system internal mfdm errors for futher analysis.

Recommended Action    No action is required.

MODULE Messages

This section contains the MODULE messages.

MODULE-2

Error Message    MODULE-2-LCM_PRE_UPGRADE_GENERAL_FAIL: Pre upgrade message fails seq 
[dec] 

Explanation    Pre upgrade message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_DONE_GENERAL_FAIL: Upgrade done message fails 
SAP [chars] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_OVER_FAIL: Upgrade over message returned [dec] 
[hex] for SAP [dec] 

Explanation    Upgrade done message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_READY_FAIL: Upgrade ready message returned [dec] 
[hex] for SAP [dec] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_READY_GENERAL_FAIL: Upgrade ready message fails 
SAP [chars] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-MOD_DIAG_FAIL: Module [dec] (serial: [chars]) reported 
failure [chars] due to [chars] in device [dec] (device error [hex])

Explanation    The module in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_DNLD_FAIL: Image download failed for module [dec] 
(serial: [chars]) 

Explanation    Module [decimal digit] failed to download a new image from the supervisor.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_FAIL: Initialization of module [dec] (serial: [chars]) 
failed 

Explanation    Module [decimal digit] reported a failure during the initialization phase and will be powered down.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all module <module number>'.

Error Message     MODULE-2-MOD_MAJORSWFAIL: Module [dec] (serial: [chars]) reported a 
critical failure in service [chars] 

Explanation    A critical failure in service [string] happened at module [decimal digit] is going to reset the module [decimal digit].

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_MINORSWFAIL: Module [dec] (serial: [chars]) reported a 
failure in service [chars] 

Explanation    A non-critical failure in service [string] happened at module [decimal digit] is not going to reset the module [decimal digit].

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_NOT_ALIVE: Module [dec] not responding... resetting 
(serial: [chars]) 

Explanation    Module [decimal digit] is not replying to the hello message: module manager is then going to reset the module.

Recommended Action    No action is required.

Error Message     MODULE-2-MOD_REGFAILED: Registration failed for module [dec] 

Explanation    Module [decimal digit] sent the registration message notifying a failure.

Recommended Action    Collect module internal information by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_SOMEPORTS_FAILED: Module [dec] (serial: [chars]) 
reported failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in 
device [dec] (error [hex])

Explanation    Module [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_UNKNOWN: Module type [[dec]] in slot [dec] is not 
supported 

Explanation    The software card id of module [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the commands 'show module internal all module [decimal digit]'

Error Message     MODULE-2-XBAR_DIAG_FAIL: Xbar [dec] (serial: [chars]) reported 
failure [chars] due to [chars] in device [dec] (device error [hex])

Explanation    The xbar in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

Error Message     MODULE-2-XBAR_FAIL: Initialization of xbar [dec] (serial: [chars]) 
failed 

Explanation    Xbar [decimal digit] reported a failure during the initialization phase and will be powered down.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.

Error Message     MODULE-2-XBAR_SOMEPORTS_FAILED: Xbar [dec] (serial: [chars]) reported 
failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] 
(error [hex])

Explanation    Xbar [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

Error Message     MODULE-2-XBAR_UNKNOWN: Xbar type [[dec]] in slot [dec] is not 
supported 

Explanation    The software card id of xbar [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the commands 'show module internal all xbar [decimal digit]'

MODULE-3

Error Message     MODULE-3-MOD_SRG_NOT_COMPATIBLE: Module [dec] (serial: [chars]) 
firmware is not compatible with supervisor, downloading new image

Explanation    The software version of module [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

MODULE-4

Error Message     MODULE-4-MOD_WARNING: Module [dec] (serial: [chars]) reported warning 
[chars] due to [chars] in device [dec] (device error [hex])

Explanation    Module [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-4-XBAR_WARNING: Xbar [dec] (serial: [chars]) reported warnings 
on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (device 
error [hex])

Explanation    Xbar [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

MODULE-5

Error Message     MODULE-5-ACTIVE_SUP_OK: Supervisor [dec] is active (serial: [chars]) 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module [dec] ended 

Explanation    Upgrade of the module has ended.

Recommended Action    No action is required.

Error Message     MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module [dec] started 

Explanation    Upgrade of the module has been started by installer

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_OK: Module [dec] is online (serial: [chars]) 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_REINIT: Re-initializing module [dec] (serial: [chars]) 

Explanation    Module [decimal digit] reported a failure during the initialization phase and will be rebooted.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all module <module number>'.

Error Message     MODULE-5-MOD_RESTART: Module [dec] is restarting after image download 

Explanation    Module [decimal digit] completed image download and is restarting.

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_STARTUP_CFG_MISMATCH: The startup configuration cannot 
be applied to a different module type for module [dec] (serial: [chars]). [chars] 
module is replacing [chars].

Explanation    The startup configuration for module [decimal digit] contains information about a different type of module instead of containing information about the current one.

Recommended Action    No action is required.

Error Message     MODULE-5-STANDBY_SUP_OK: Supervisor [dec] is standby 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-XBAR_OK: Xbar [dec] is online (serial: [chars]) 

Explanation    Xbar [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-XBAR_REINIT: Re-initializing xbar [dec] (serial: [chars]) 

Explanation    Xbar [decimal digit] reported a failure during the initialization phase and will be rebooted.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.

MODULE-6

Error Message     MODULE-6-MOD_PURGE_CONFIG: Purging the configuration for module [dec] 

Explanation    Notification is being sent to remove the module configurations.

Recommended Action    No action is required.

Error Message     MODULE-6-MOD_REG_OK: Registration succeeded for module [dec] 

Explanation    Module [decimal digit] sent a successful registration message.

Recommended Action    No action is required.

MONITOR Messages

This section contains the MONITOR messages.

MONITOR-3

Error Message    MONITOR-3-ETH_SPAN_CFG_DEST_IF_MEMBER_SRC_PROFILE: ERROR: Interface 
[[chars]] configured in session [[dec]] and being inherited by port profile 
[[chars]] in another session

Explanation    An interface is configured as destination and source at the same time (one as being inherited by a port-profile and the other as being directly configured as a source/destination of a session. This may result of monitor traffic loss in the interface. Please remove the interface from the port profile or from the monitor session.

Recommended Action    No action is required.

MONITOR-5

Error Message     MONITOR-5-ETH_SPAN_SESSION_DOWN: Session [dec] is down. Reason 
[chars] 

Explanation    Session is down, no further traffic will be spanned.

Recommended Action    No action is required.

Error Message     MONITOR-5-ETH_SPAN_SESSION_ERROR: Session [dec] is having error. 
Reason [chars] 

Explanation    The session is experiencing a problem.

Recommended Action    Delete the session and try to reconfigure it

Error Message     MONITOR-5-ETH_SPAN_SESSION_UP: Session [dec] is up. 

Explanation    Session is up now. You can monitor Spanned traffic at the destination ports

Recommended Action    No action is required.

MONITOR-6

Error Message     MONITOR-6-ETH_SPAN_SESSION_CREATED: Session [dec] created 

Explanation    A new span session has been created.

Recommended Action    No action is required.

Error Message     MONITOR-6-ETH_SPAN_SESSION_DELETED: Session [dec] deleted 

Explanation    Session has been deleted.

Recommended Action    No action is required.

NFM Messages

This section contains the NFM messages.

NFM-2

Error Message    NFM-2-COMMIT_FAIL: Commit failed: client [hex], [chars] 

Explanation    The DDB commit failed

Recommended Action    No action is required.

Error Message     NFM-2-DDB_FAILURE: DDB failure: [chars] 

Explanation    A DDB generated failure

Recommended Action    No action is required.

Error Message     NFM-2-EXITING: Exit reason: [chars] 

Explanation    The NFM service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     NFM-2-INIT_FAIL: NFM Service Init failed: [chars] 

Explanation    NFM Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     NFM-2-MALLOC_ERROR: Function [chars]: Size [dec] bytes 

Explanation    The NFM service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NFM-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The NFM service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-2-VERIFY_FAIL: Verify failed - Client [hex], Reason: [chars], 
Interface: [chars] 

Explanation    The DDB Verify failed

Recommended Action    No action is required.

NFM-3

Error Message     NFM-3-DDB_ERROR: DDB error: [chars] 

Explanation    The DDB generated error

Recommended Action    No action is required.

Error Message     NFM-3-FEATURE_MANAGER_ERROR: [chars]: An error occurred processing a 
Feature Manager msg - error [chars] 

Explanation    An error occurred while processing a message from FEATURE Manager

Recommended Action    No action is required.

Error Message     NFM-3-HANDLE_IN_USE: [chars]: name: [chars] 

Explanation    The NFM service encountered a handle that was in use while reading a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-3-INVALID_HANDLE: [chars]: handle =[hex] 

Explanation    The NFM service encountered an invalid handle in a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-3-MONITOR_NOT_FOUND: Monitor with handle [hex] from source [hex] 

Explanation    An Export Msg from a Linecard contained an invalid Monitor handle

Recommended Action    No action is required.

Error Message     NFM-3-MTS_ERROR: NFM encountered the following MTS error: [chars] 

Explanation    NFM Service encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     NFM-3-NFM_DDB_ERROR: DDB error: [chars] 

Explanation    The DDB generated error

Recommended Action    No action is required.

Error Message     NFM-3-PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The NFM service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     NFM-3-VLAN_PARSE_ERROR: [chars]: An error occurred processing a VLAN 
Mgr Parse msg [hex] 

Explanation    An error occurred while processing a message from VLAN Manager

Recommended Action    No action is required.

NFM-4

Error Message     NFM-4-DDB_WARNING: DDB warning: [chars] 

Explanation    The DDB generated warning

Recommended Action    No action is required.

Error Message     NFM-4-LICENSE_EXPIRED: The License has expired. 

Explanation    The NFM service requires a License to run and exits when the License expires.

Recommended Action    No action is required.

Error Message     NFM-4-NFM_DDB_WARNING: DDB warning: [chars] 

Explanation    The DDB generated warning

Recommended Action    No action is required.

Error Message     NFM-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the NFM service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

NFM-5

Error Message     NFM-5-FEATURE_DISABLED: NetFlow Disabled. 

Explanation    NetFlow Feature Disabled.

Recommended Action    No action is required.

Error Message     NFM-5-FEATURE_ENABLED: NetFlow Enabled. 

Explanation    NetFlow Feature Enabled.

Recommended Action    No action is required.

NFM-6

Error Message     NFM-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The NFM service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     NFM-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The NFM service became standby from active mode.

Recommended Action    No action is required.

Error Message     NFM-6-DDB_NOTIF: DDB notification: [chars] 

Explanation    The DDB generated notification

Recommended Action    No action is required.

Error Message     NFM-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The NFM service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     NFM-6-NFM_DDB_NOTIF: DDB notification: [chars] 

Explanation    The DDB generated notification

Recommended Action    No action is required.

Error Message     NFM-6-SERVICE_UP: Initialized [chars] 

Explanation    The NFM service is up and ready The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     NFM-6-SRV_EXIT: NFM Service shutting down gracefully 

Explanation    NFM Service is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     NFM-6-SWITCH_OVER: Switching Over to other Sup. 

Explanation    The NFM service has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

NFM-7

Error Message     NFM-7-DEBUG: [chars] 

Explanation    Debug information is being sent to syslog

Recommended Action    No action is required.

NFP Messages

This section contains the NFP messages.

NFP-SLOT#-2

Error Message    NFP-SLOT#-2-NF_ACL_ERR: [chars]([dec]): acl error. [chars] 

Explanation    Acl error

Recommended Action    No DDTS.

Error Message     NFP-SLOT#-2-NF_DDB_ERR: [chars]([dec]): ddb error. [chars] 

Explanation    Ddb error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NFP-SLOT#-2-NF_ERR: [chars]([dec]): nfp error. [chars] 

Explanation    Nfp error occured

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NFP-SLOT#-2-NF_FIB_ERR: [chars]([dec]): fib error. [chars] 

Explanation    Fib error

Recommended Action    No DDTS.

Error Message     NFP-SLOT#-2-NF_NDE_ERR: [chars]([dec]): nde error. [chars] 

Explanation    Nde error

Recommended Action    No DDTS.

Error Message     NFP-SLOT#-2-NF_NFM_ERR: [chars]([dec]): nfm error. [chars] 

Explanation    Nfm error

Recommended Action    No DDTS.

Error Message     NFP-SLOT#-2-NF_QOS_ERR: [chars]([dec]): qos error. [chars] 

Explanation    Qos error

Recommended Action    No DDTS.

NPC Messages

This section contains the NPC messages.

NPC-SLOT#-3

Error Message    NPC-SLOT#-3-LOG_NPC_ERR: Nonrecoverable error: [chars] 

Explanation    Errors which cause program to exit occurred

Recommended Action    No action is required.

NPC-SLOT#-4

Error Message     NPC-SLOT#-4-LOG_NPC_WARNING: Serious error: [chars] 

Explanation    Serious errors which affect all normal operations occurred

Recommended Action    No action is required.

NPC-SLOT#-5

Error Message     NPC-SLOT#-5-LOG_NPC_DEBUG: Unexpected error: [chars] 

Explanation    Unexpected errors which affect some normal operations occurred

Recommended Action    No action is required.

Error Message     NPC-SLOT#-5-LOG_NPC_NVP_FSM: Illegal event received: [chars] 

Explanation    Illegal event received in NPC_NVP FSM

Recommended Action    No action is required.

Error Message     NPC-SLOT#-5-LOG_NPC_VSAN_FSM: Illegal event received: [chars] 

Explanation    Illegal event received in NPC_VSAN FSM

Recommended Action    No action is required.

NPV Messages

This section contains the NPV messages.

NPV-2

Error Message    NPV-2-CFS_PEER_LOST_WITHIN_SESSION: CFS peer with switch wwn [chars] 
was lost in the middle of an active CFS session. Abort the CFS session and re-enter 
the configuration changes

Explanation    Due to port flaps, link outages, switch restart etc. a CFS peer switch of NPV was lost. The current configuration changes would not be applied to this peer until the peer merges with this switch. The CFS merge may fail if the configuration at the lost peer conflicts with the changes made in this session. It is recommended that the user abort this CFS session using ivr abort command and then re-enter the configuration changes.

Recommended Action    No action is required.

Error Message     NPV-2-NPV_DISABLE_FAILED: NPV could not disabled : [chars] [chars] 

Explanation    NPM could not disabled due to the reason specified. Please try again.

Recommended Action    No action is required.

Error Message     NPV-2-NPV_ENABLE_FAILED: NPV could not enabled : [chars] [chars] 

Explanation    NPM could not enabled due to the reason specified. Please try again.

Recommended Action    No action is required.

Error Message     NPV-2-NPV_EXITED: NPV process exited in file [chars] at Line 
[chars]:[chars] 

Explanation    NPM process encountered a critical error as specified, and so NPV process cannot continue.

Recommended Action    No action is required.

NPV-3

Error Message     NPV-3-ACL_UPDATE_FAILED: [chars] 

Explanation    ACL update request initiated by the NPV process has failed

Recommended Action    No action is required.

Error Message     NPV-3-CFS_INVALID_PAYLOAD_RECEIVED: NPV received invalid payload from 
CFS 

Explanation    NPV process received invalid payload from CFS.

Recommended Action    No action is required.

Error Message     NPV-3-CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-COMMIT_FAILED: [chars] 

Explanation    An error occurred while committing configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-COMMIT_PARTIALLY_FAILED: [chars] 

Explanation    An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-COMMIT_REJECTED: [chars] 

Explanation    Commit request received from remote switch is rejected. The reason for the failure: [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-FC2_SEND_FAILED: [chars] 

Explanation    NPV process could send an FC2 message.

Recommended Action    No action is required.

Error Message     NPV-3-F_RJT_SENT: [chars] 

Explanation    NPV process sent an F_RJT frame.

Recommended Action    No action is required.

Error Message     NPV-3-INTERNAL_ERROR: Internal error: [chars] 

Explanation    NPV process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     NPV-3-LCP_PROGRAMMING_FAILED: [chars] 

Explanation    LCP programming request initiated by the NPV process has failed

Recommended Action    No action is required.

Error Message     NPV-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-LS_RJT_RCVD: [chars] 

Explanation    NPV process received an LS_RJT frame.

Recommended Action    No action is required.

Error Message     NPV-3-LS_RJT_SENT: [chars] 

Explanation    NPV process sent an LS_RJT frame.

Recommended Action    No action is required.

Error Message     NPV-3-MALLOC_FAILED: [chars] 

Explanation    NPV process could not allocate memory

Recommended Action    No action is required.

Error Message     NPV-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    An error occurred while activating merged configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-MERGE_FAILED: [chars] 

Explanation    An error occurred while merging configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NPV-3-MTS_SEND_FAILED: [chars] 

Explanation    NPV process could not send an MTS message.

Recommended Action    No action is required.

Error Message     NPV-3-NPIV_DISABLE_FAILED: [chars] 

Explanation    NPIV feature could not be disabled.

Recommended Action    No action is required.

Error Message     NPV-3-NPV_CFS_IPV4_ENABLE_FAILED: CFS IPv4 distribution enable failed 
because [chars] 

Explanation    NPV CFS distribution might not work. Try enabling it again on the command line. Make sure cfs distribution is enabled.

Recommended Action    No action is required.

Error Message     NPV-3-PORT_BRINGUP_FAILED: [chars] 

Explanation    NPV process has failed to bringup the port

Recommended Action    No action is required.

Error Message     NPV-3-PORT_REINIT_FAILED: [chars] 

Explanation    Port reinit request initiated by the NPV process has failed

Recommended Action    No action is required.

Error Message     NPV-3-UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

NPV-4

Error Message     NPV-4-NPV_NPIV_NOT_ENABLED_ON_UPSTREAM_SWITCH: [chars] 

Explanation    This syslog is printed when the external interface fails to come up due to NPIV feature not enabled on the upstream switch.

Recommended Action    Verify and enable NPIV feature in upstream switch.

Error Message     NPV-4-NPV_PORT_VSAN_MISMATCH_ON_UPSTREAM_LINK: [chars] 

Explanation    This syslog is printed when the external interface fails to come up due to upstream port VSAN mis-match with the upstream switch.

Recommended Action    Make sure port VSAN is same on both sides of this external link

NPV-5

Error Message     NPV-5-ASSERTION_FAILED: Unexpected assertion failure in File [chars] 
at Line [dec] 

Explanation    An assertion failed in NPV code

Recommended Action    No action is required.

Error Message     NPV-5-FLEXATTACH_VPWWN_AUTO_ASSIGNED: A virtual port WWN [chars] has 
been automatically assigned to interface [chars] 

Explanation    The virtual port WWN will be used as port WWN for devices logging in on this interface.

Recommended Action    No action is required.

Error Message     NPV-5-FLEXATTACH_VPWWN_MANUALLY_ASSIGNED: A virtual port WWN [chars] 
has been manually assigned to interface [chars] 

Explanation    The virtual port WWN will be used as port WWN for devices logging in on this interface.

Recommended Action    No action is required.

Error Message     NPV-5-FLEXATTACH_VPWWN_UNASSIGNED: The virtual port WWN has been 
unassigned from interface [chars] 

Explanation    The physical port WWN will be used as port WWN for devices logging in on this interface.

Recommended Action    No action is required.

Error Message     NPV-5-FRAME_DISCARDED: [chars] 

Explanation    NPV process discarded an FC2 frame.

Recommended Action    No action is required.

Error Message     NPV-5-NPV_LOAD_BALANCE_REINIT: Server ports reinitialized : [chars] 

Explanation    Server ports are reinitialized to balance the loads on the external interfaces.

Recommended Action    No action is required.

Error Message     NPV-5-UNEXPECTED_EVENT: [chars] 

Explanation    NPV process has received an unexpected event in the current state.

Recommended Action    No action is required.

NPV-6

Error Message     NPV-6-ABTS_SENT: [chars] 

Explanation    NPV process sent an ABTS frame.

Recommended Action    No action is required.

Error Message     NPV-6-ELS_CMD_SENT_TO_CORE: [chars] 

Explanation    NPV process sent an ELS frame to the core switch.

Recommended Action    No action is required.

Error Message     NPV-6-ELS_CMD_SENT_TO_SRV: [chars] 

Explanation    NPV process sent an ELS frame to the server.

Recommended Action    No action is required.

Error Message     NPV-6-EXT_IF_SELECTED: [chars] 

Explanation    NPV process has selected an external interface to forward either all frames received on a server interface or frames received from a specific port WWN.

Recommended Action    No action is required.

Error Message     NPV-6-FABRIC_PROXY_LOGO_SENT: [chars] 

Explanation    NPV process sent a LOGO frame to the device as the corresponding external interface went down.

Recommended Action    No action is required.

Error Message     NPV-6-FDISC_RCVD: [chars] 

Explanation    NPV process received an FDISC frame.

Recommended Action    No action is required.

Error Message     NPV-6-FDISC_SENT: [chars] 

Explanation    NPV process sent an FDISC frame to the core switch.

Recommended Action    No action is required.

Error Message     NPV-6-FLOGI_RCVD: [chars] 

Explanation    NPV process received an FLOGI frame.

Recommended Action    No action is required.

Error Message     NPV-6-INTERNAL_FLOGI_SENT: [chars] 

Explanation    NPV process sent an internal FLOGI frame to the core switch on an external interface.

Recommended Action    No action is required.

Error Message     NPV-6-LOGO_RCVD: [chars] 

Explanation    NPV process received a LOGO frame.

Recommended Action    No action is required.

Error Message     NPV-6-LOGO_SENT: [chars] 

Explanation    NPV process sent a LOGO frame.

Recommended Action    No action is required.

Error Message     NPV-6-LS_ACC_RCVD: [chars] 

Explanation    NPV process received an LS_ACC frame.

Recommended Action    No action is required.

Error Message     NPV-6-LS_ACC_SENT: [chars] 

Explanation    NPV process sent an LS_ACC frame.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_NOTIF_RCVD: [chars] 

Explanation    NPV process received an MTS notification.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_NOTIF_SENT: [chars] 

Explanation    NPV process sent an MTS notification.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_REQ_RCVD: [chars] 

Explanation    NPV process received an MTS request.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_REQ_SENT: [chars] 

Explanation    NPV process sent an MTS request.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_RESP_RCVD: [chars] 

Explanation    NPV process received an MTS response.

Recommended Action    No action is required.

Error Message     NPV-6-MTS_RESP_SENT: [chars] 

Explanation    NPV process sent an MTS response.

Recommended Action    No action is required.

Error Message     NPV-6-NPIV_DISABLED: [chars] 

Explanation    NPIV feature has been disabled.

Recommended Action    No action is required.

Error Message     NPV-6-NPIV_ENABLED: [chars] 

Explanation    NPIV feature has been enabled.

Recommended Action    No action is required.

Error Message     NPV-6-NPV_ENABLE_DISABLE_IN_PROGRESS: [chars] 

Explanation    NPV feature enable/disable is in progress. This syslog is printed at the beginning of various significant phases.

Recommended Action    No action is required.

Error Message     NPV-6-NPV_LOAD_BALANCE_TIMER_START: (Re)starting automatic load 
balancing timer for [dec] seconds 

Explanation    Timer started for upon external interface up or server interface down. When the timer goes off some of the server interfaces may be reinitialized to evenly distribute the server interfaces amongst the eligible external interfaces.

Recommended Action    No action is required.

Error Message     NPV-6-SERVER_PROXY_LOGO_SENT: [chars] 

Explanation    NPV process sent a LOGO frame to the core switch as the server interface went down.

Recommended Action    No action is required.

NPV-7

Error Message     NPV-7-CFS_REQ_RCVD: [chars] 

Explanation    CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.

Recommended Action    No action is required.

Error Message     NPV-7-CFS_RESP_SENT: [chars] 

Explanation    CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message

Recommended Action    No action is required.

NTP Messages

This section contains the NTP messages.

NTP-2

Error Message    NTP-2-NTP_SYSLOG_CRIT_ERR: : [chars] 

Explanation    NTP syslog Critial Error : [chars].

Recommended Action    No action is required.

Error Message     NTP-2-NTP_SYSLOG_INIT_FAIL: : [chars] [chars] 

Explanation    NTP Initialization Failed: [chars] [chars].

Recommended Action    No action is required.

Error Message     NTP-2-NTP_SYSLOG_NO_RESP_FROM_LC: from LC[dec] for [chars] 

Explanation    NTP did not receive response from the linecard for the request sent.

Recommended Action    No action is required.

NTP-3

Error Message     NTP-3-NTP_SYSLOG_ALLOC_FAIL: : [chars] 

Explanation    NTP syslog allocation failed : [chars].

Recommended Action    No action is required.

Error Message     NTP-3-NTP_SYSLOG_ERR_EXT: : [chars] [chars] 

Explanation    NTP syslog Error Exit : [chars] [dec].

Recommended Action    No action is required.

Error Message     NTP-3-NTP_SYSLOG_ERR: : [chars] 

Explanation    NTP syslog Error : [chars].

Recommended Action    No action is required.

Error Message     NTP-3-NTP_SYSLOG_MTS_ERR: : [chars] 

Explanation    NTP MTS Error : [chars].

Recommended Action    No action is required.

NTP-6

Error Message     NTP-6-NTP_SYSLOG_CREATED: : [chars]; Slot No: [dec] 

Explanation    NTP syslog created : [chars] [chars].

Recommended Action    No action is required.

Error Message     NTP-6-NTP_SYSLOG_EXIT: : [chars] 

Explanation    NTP syslog Exit : [chars].

Recommended Action    No action is required.

Error Message     NTP-6-NTP_SYSLOG_LOGGING: : [chars] 

Explanation    NTP logging : [chars].

Recommended Action    No action is required.

Error Message     NTP-6-NTP_SYSLOG_WARN: : [chars] 

Explanation    NTP syslog Warning : [chars].

Recommended Action    No action is required.

NVP Messages

This section contains the NVP messages.

NVP-6

Error Message    NVP-6-NVP_INFO: [chars] 

Explanation    NVP daemon informational message

Recommended Action    No action is required.

Error Message     NVP-6-STARTING: deamon started 

Explanation    The NVP daemon successfully started

Recommended Action    No action is required.

NVP-SLOT#-2

Error Message     NVP-SLOT#-2-CPP_CATASTROPHIC_ERROR: ERROR: Component ([chars]) caused 
critical error please reboot SSM 

Explanation    Component caused critical error

Recommended Action    Restart the linecard

OC_USD Messages

This section contains the OC_USD messages.

OC_USD-2

Error Message    OC_USD-2-RF_CRC: [chars] 

Explanation    Octopus received packets with CRC error from fabric

Recommended Action    No action is required.

ORI_MAC Messages

This section contains the ORI_MAC messages.

ORI_MAC-6

Error Message    ORI_MAC-6-ORI_MAC_DEBUG_MSG: [chars] 

Explanation    Debug log message

Recommended Action    No action is required.

OTM Messages

This section contains the OTM messages.

OTM-2

Error Message    OTM-2-OTM_EEM_FAIL: OTM failed to register with EEM 

Explanation    OTM process failed to register with eem, exiting now

Recommended Action    No action is required.

OTM-3

Error Message     OTM-3-OTM_ERROR: [chars] [chars] 

Explanation    [chars1][chars2]

Recommended Action    No action is required.

OTM-5

Error Message     OTM-5-OTM_OBJECT_STATUS: Status of tracking object [dec] changed to 
[chars] 

Explanation    Status of tracking object [dec] changed to [chars]

Recommended Action    No action is required.

OTM-6

Error Message     OTM-6-OTM_EXITED: OTM process exited 

Explanation    OTM process is terminated

Recommended Action    No action is required.

Error Message     OTM-6-OTM_OBJ_ADD: : Tracking object [dec] configured, status of the 
object [chars] 

Explanation    Tracking Object [dec] configured, status of the object [chars]

Recommended Action    No action is required.

Error Message     OTM-6-OTM_OBJ_REM: : Tracking object [dec] removed 

Explanation    Tracking Object [dec] removed

Recommended Action    No action is required.

Error Message     OTM-6-OTM_STARTED: OTM process started 

Explanation    OTM process is up and running

Recommended Action    No action is required.

Error Message     OTM-6-OTM_TRACK_START: Client started tracking object [dec] 

Explanation    Client has started tracking object [dec]

Recommended Action    No action is required.

Error Message     OTM-6-OTM_TRACK_STOP: Client stopped tracking object [dec] 

Explanation    Client has stopped tracking object [dec]

Recommended Action    No action is required.

PHY_USD Messages

This section contains the PHY_USD messages.

PHY_USD-SLOT#-4

Error Message    PHY_USD-SLOT#-4-LOG_PHY_ISSU_LINK_ST_CHNG: Port [dec]: link state 
during ISSU 

Explanation    Port Link status changed while perfoming an In Service System Upgrade. Disabling the port.

Recommended Action    No action is required.

PIXM Messages

This section contains the PIXM messages.

PIXM-2

Error Message    PIXM-2-PIXM_CRIT: [chars] 

Explanation    PIXM or other application had critical error

Recommended Action    No action is required.

PIXM-3

Error Message     PIXM-3-PIXM_ERR: [chars] 

Explanation    PIXM or other application had some error

Recommended Action    No action is required.

Error Message     PIXM-3-PIXM_FAILURE: PIXM / PIXMC ERROR, [chars] 

Explanation    PIXMC or other application did not respond with a timelimit or something bad happened

Recommended Action    No action is required.

Error Message     PIXM-3-PIXM_SYSLOG_UPGRADE_OVER: [chars] 

Explanation    PIXM received UPGRADE_OVER before receiving UPGRADE_READY for slot:[dec]

Recommended Action    No action is required.

PIXM-4

Error Message     PIXM-4-PIXM_SEND_FAILURE: PIXM SEND FAILURE, [chars] 

Explanation    PIXM was not able to send to PIXMC or other application

Recommended Action    No action is required.

Error Message     PIXM-4-PIXM_VDC_CLEANUP: VDC Cleanup, [chars] 

Explanation    Application like PC, MD, Mcast should have cleaned up the LTL for VDC Graceful cleanup

Recommended Action    No action is required.

Error Message     PIXM-4-PIXM_WARN: [chars] 

Explanation    PIXM or other application had some minor issues

Recommended Action    No action is required.

PLATFORM Messages

This section contains the PLATFORM messages.

PLATFORM-0

Error Message    PLATFORM-0-CHASSIS_CLKSWITCH: Hardware clock switched to redundant 
clock-[dec] 

Explanation    Clock module on chassis deteted a failure and switched to redundant clock module.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-0-CHASSIS_CLKSWRESET: Switch reset due to clock switch 

Explanation    Chassis clock source has failed and system will be reset. System will automatically start using redundant clock module.

Recommended Action    Please refer to the platform document on clock modules.

Error Message     PLATFORM-0-CHASSIS_CLKSW_MODULE_RESET: Modules reset due to clock 
switch 

Explanation    Chassis clock source has switched and all Vegas line cards will be reset. System will automatically continue using redundant clock module.

Recommended Action    Please refer to the platform document on clock modules.

Error Message     PLATFORM-0-FAIL_REMOVED: Fan module removed. Fan[dec] has been absent 
for [dec] seconds 

Explanation    Fan module is removed. This could lead to temperature alarms.

Recommended Action    Replace the fan module ASAP.

Error Message     PLATFORM-0-MOD_TEMPMAJALRM: [chars] reported Major temperature alarm. 
Sensor=[dec] Temperature=[dec] MajThreshold=[dec] 

Explanation    Module in slot [decimal digit] exceeded major temperature threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-0-MOD_TEMPSHUTDOWN: [chars] powered down due to major 
temperature alarm for Sensor [dec]. 

Explanation    Module in slot [decimal digit] shutdown due to temperature exceeding major threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-0-PFM_EMERGENCY: [chars] 

Explanation    Platform Emergency

Recommended Action    No action is required.

Error Message     PLATFORM-0-SUP_SPROM_ERROR: Unable to read SPROM for Sup in slot [dec] 

Explanation    The supervisor in slot [decimal digit] was not able to read its SPROM.

Recommended Action    No action is required.

Error Message     PLATFORM-0-SUP_WRONGSLOTNUM: Supervisor powered up in WRONG 
SLOT:[dec] (Serial number [chars]) 

Explanation    The supervisor is comming up in wrong slot [decimal digit].

Recommended Action    No action is required.

Error Message     PLATFORM-0-SYS_LC_DRIVER_LOAD_FAILED: Failed to load linecard module 
drivers 

Explanation    Failed to load drivers.

Recommended Action    Image is possibly corrupt. Try to load a different image.

Error Message     PLATFORM-0-SYS_RESET: [chars] System shutdown in [dec] seconds 

Explanation    System shutdown in [decimal digit] seconds.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-0-SYS_SHUTDOWN_FAN_REMOVAL: System shutdown in [dec] seconds 
due to fan removal 

Explanation    System shutdown in [decimal digit] seconds due to removal of fan module.

Recommended Action    Please perform a 'show env fan' to collect more information.

Error Message     PLATFORM-0-SYS_SHUTDOWN_MDS9124_FAN_FAIL: System shutdown in [dec] 
seconds due to less than 4 fans operating. 

Explanation    System shutdown in [decimal digit] seconds due to less than 4 fans operating.

Recommended Action    Please perform a 'show env fan' to collect more information.

Error Message     PLATFORM-0-SYS_SHUTDOWN: System shutdown in [dec] seconds due to major 
temperature alarm 

Explanation    System shutdown in [decimal digit] seconds due to temperature exceeding major threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-0-SYS_SUP_DRIVER_LOAD_FAILED: Failed to load supervisor 
module drivers 

Explanation    Failed to load drivers.

Recommended Action    Image is possibly corrupt. Try to load a different image

Error Message     PLATFORM-0-XBAR_CARD_CLK_FAIL: Xbar card in slot:[dec] (Serial number 
[chars]) encountered clock failure 

Explanation    The xbar in slot [decimal digit] encountered clock failure.

Recommended Action    No action is required.

Error Message     PLATFORM-0-XBAR_CARD_INCOMPAT_CHASSIS: Xbar card in slot:[dec] (Part 
number [chars]) Incompatible with backplane chassis Part Num:[chars] 

Explanation    The xbar in slot [decimal digit] is incompatible with backplane chassis.

Recommended Action    No action is required.

Error Message     PLATFORM-0-XBAR_WRONGSLOTNUM: Xbar powered up in WRONG SLOT:[dec] 
(Serial number [chars]) 

Explanation    The xbar in slot [decimal digit] powered up in wrong slot.

Recommended Action    No action is required.

PLATFORM-1

Error Message     PLATFORM-1-FABRIC_SWITCH_FAN_FAIL: Less than 4 required fans 
operating. 

Explanation    Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-1-FAN_FAIL: Fan module Failed 

Explanation    Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-1-PFM_ALERT: [chars] 

Explanation    Platform Alert

Recommended Action    No action is required.

Error Message     PLATFORM-1-PS_SINGLE_INPUT: Both power inputs are connected for Power 
supplies, remove single-input configuration for optimal power usage 

Explanation    Current power supply redundancy mode may not be optimal

Recommended Action    Please perform a 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-1-XBAR_PWRDENY: Xbar [dec] can not be powered up due to 
insufficient power (Serial number [chars]) 

Explanation    Available power in power supplies is not sufficient to power up the xbar

Recommended Action    You can verify available power and current usage using command 'show env power'. Please refer to power supply document on how to increase power supply capacity.

PLATFORM-2

Error Message     PLATFORM-2-9134_FAN_FAIL: Fan module [dec] Failed 

Explanation    Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-9134_FAN_OK: Fan module [dec] ok 

Explanation    Fan module is ok

Recommended Action    No action is required.

Error Message     PLATFORM-2-CASA_FAN_FAIL: Fan module [dec] Failed 

Explanation    Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-CASA_FAN_OK: Fan module [dec] ok 

Explanation    Fan module is ok

Recommended Action    No action is required.

Error Message     PLATFORM-2-CHASSIS_CLKMODFAULTY: Chassis clock module [dec] faulty 

Explanation    Clock module on chassis is faulty or has been removed.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-CHASSIS_CLKMODOK: Chassis clock module [dec] ok 

Explanation    Clock module on chassis is functioning properly.

Recommended Action    No action is required.

Error Message     PLATFORM-2-CHASSIS_CLKSRC: Current chassis clock source is 
clock-[dec] 

Explanation    The current chassis clock source is [decimal digit].

Recommended Action    No action is required.

Error Message     PLATFORM-2-FANLET_FAN_FAIL: Failed Fanlets for Fan [dec] ([chars] 
fan) : [chars] 

Explanation    The specified fanlets have failed. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-FANMOD_FAN_FAIL: Fan module [dec] ([chars] fan) 
Failed/Removed 

Explanation    Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.

Recommended Action    Please perform a 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-FANMOD_FAN_OK: Fan module [dec] ([chars] fan) ok 

Explanation    Fan module is ok

Recommended Action    No action is required.

Error Message     PLATFORM-2-FAN_OK: Fan module ok 

Explanation    Fan module is ok

Recommended Action    No action is required.

Error Message     PLATFORM-2-FAN_REMOVED: Fan module [dec] (Serial number [chars]) 
[chars] removed 

Explanation    Fan module is removed

Recommended Action    No action is required.

Error Message     PLATFORM-2-MEMORY_ALERT: Memory Status Alert : [chars] 

Explanation    Memory alert event received

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-MOD_ALL_PWRDN_NOXBAR: All modules powered down due to 
non-availability of xbar modules 

Explanation    All modules in switch are powered down because all xbar modules are offline

Recommended Action    Please perform a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors. Atleast one xbar module has to be for modules to function

Error Message     PLATFORM-2-MOD_DETECT: Module [dec] detected (Serial number [chars]) 
Module-Type [chars] Model [chars] 

Explanation    A new module in slot [decimal digit] is detected.

Recommended Action    No action is required.

Error Message     PLATFORM-2-MOD_PWRDENY: Module [dec] can not be powered up due to 
insufficient power (Serial number [chars]) 

Explanation    Available power in power supplies is not sufficient to power up the module

Recommended Action    You can verify available power and current usage using command 'show env power'. Please refer to power supply document on how to increase power supply capacity.

Error Message     PLATFORM-2-MOD_PWRDN: Module [dec] powered down (Serial number 
[chars]) 

Explanation    The module in slot [decimal digit] is powered down.

Recommended Action    Please perform a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors.

Error Message     PLATFORM-2-MOD_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Module 
[dec] will not be powered up (Serial number [chars]) 

Explanation    The module can not be powered up because both ejectors are open

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-2-MOD_PWRFAIL: Module [dec] failed to power up (Serial number 
[chars]) 

Explanation    The module in slot [decimal digit] failed to power up

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and to collect more information.

Error Message     PLATFORM-2-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to 
IDPROM read error 

Explanation    The module can not be powered up due to IDPROM read error

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-2-MOD_PWRIDPROM_SW_CARD_ID_UNKNOWN: Module [dec] failed to 
power up. (Unknown card. Could not get software-card-id) 

Explanation    The module can not be powered up due to missing SWID in core-plugin for this CARDID

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-2-MOD_PWRUP_XBAR: Modules powered up due to xbar 
availability 

Explanation    Modules powered up because atleast one xbar module is online

Recommended Action    No action needed

Error Message     PLATFORM-2-MOD_PWRUP: Module [dec] powered up (Serial number [chars]) 

Explanation    The module in slot [decimal digit] is powered up.

Recommended Action    No action is required.

Error Message     PLATFORM-2-MOD_REMOVE: Module [dec] removed (Serial number [chars]) 

Explanation    The module in slot [decimal digit] has been removed.

Recommended Action    No action is required.

Error Message     PLATFORM-2-MOD_TEMPMAJOR_OK: [chars] recovered from major temperature 
alarm. Sensor=[dec] Temperature=[dec] MajThreshold=[dec] 

Explanation    Module in slot [decimal digit] major temperature threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-2-MOD_TEMPMINALRM: [chars] reported minor temperature alarm. 
Sensor=[dec] Temperature=[dec] MinThreshold=[dec] 

Explanation    Module in slot [decimal digit] has exceeded minor temperature threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-2-MOD_TEMPOK: [chars] recovered from minor temperature 
alarm. Sensor=[dec] Temperature=[dec] MinThreshold=[dec] 

Explanation    Module in slot [decimal digit] minor temperature threshold.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-2-MOD_TEMPRECOVER: [chars] recovered from major temperature 
alarm. Minor temperature alarm pending. Sensor=[dec] Temperature=[dec] 
MajThreshold=[dec] MinThresh=[dec] 

Explanation    Module in slot [decimal digit] recovered from major temperature threshold. Minor threshold still exceeded.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-2-PFM_CRITICAL: [chars] 

Explanation    Platform Critical

Recommended Action    No action is required.

Error Message     PLATFORM-2-PFM_FATW_BUS_SWITCH_FAIL: Backplane two wire [chars] bus 
connection fault detected but failed to perform bus switchover(BUS_A to BUS_B) 

Explanation    Could not access some modules using BUS_A, but can access using BUS_B

Recommended Action    Please perform a 'show platform internal err'

Error Message     PLATFORM-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus 
connection or device fault caused bus switchover(BUS_A to BUS_B) 

Explanation    Could not access some modules using BUS_A, but can access using BUS_B

Recommended Action    Please perform a 'show platform internal err'

Error Message     PLATFORM-2-PFM_IMG_CMPT_FAIL: Image version is not supported in this 
chassis. 

Explanation    This image version is not supported in this chassis.

Recommended Action    Sup-platform

Error Message     PLATFORM-2-PFM_LC_BOOT_DEV_ABSENT: No bootflash found in Module [dec] 

Explanation    No bootflash found.

Recommended Action    Try to put in a bootflash in the module and try again.

Error Message     PLATFORM-2-PFM_LC_BOOT_DEV_FAIL: Bootflash access error in Module 
[dec] 

Explanation    Bad bootflash/corrupted filesystem.

Recommended Action    Try to put in a known good bootflash in the module and try again.

Error Message     PLATFORM-2-PFM_LC_MOD_POWERED_DOWN: Module [dec] Powered Down. Module 
is not supported in this chassis. (Chassis Incompatible card) 

Explanation    Module Powered Down, because Module is not supported in this chassis. (Chassis Incompatible card)

Recommended Action    Please perform a 'show module' to see the Power Down reason.

Error Message     PLATFORM-2-PFM_LC_NETBOOT_FAIL: Netboot for Module [dec] failed 

Explanation    Netboot failed.

Recommended Action    Try to replace the BIOS in the module.

Error Message     PLATFORM-2-PFM_LC_REGISTRATION_FAIL: Could not register with Module 
[dec] 

Explanation    Module registration failed.

Recommended Action    Try to replace the module.

Error Message     PLATFORM-2-PFM_LC_STATUS: Module [dec] powered up with [dec] status 

Explanation    Status for the module that failed registration.

Recommended Action    Try to replace the module.

Error Message     PLATFORM-2-PFM_LOW_MEMORY_CONDITION: Module [dec] is running low on 
memory. %ld percent used 

Explanation    Supervisor is running low on memory

Recommended Action    Switchover

Error Message     PLATFORM-2-PFM_MODULE_POWER_OFF_TRIGGER: Power-off [chars] due to 
[chars] policy trigger 

Explanation    Policy trigger initiated a module poweroff

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_MODULE_POWER_OFF: Manual power-off of [chars] from 
Command Line Interface 

Explanation    User initiated a module power-off from the CLI

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_MODULE_POWER_ON: Manual power-on of [chars] from 
Command Line Interface 

Explanation    User initiated a module power-on from the CLI

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_MODULE_RESET: Manual restart of Module [dec] from 
Command Line Interface 

Explanation    User initiated a module reload from the CLI

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_NETBOOT_DISABLE: Netboot for supervisor module in slot 
[dec] is disabled due to incompatible platform 

Explanation    Standby supervisor failed to powerup.

Recommended Action    Try to replace the standby supervisor.

Error Message     PLATFORM-2-PFM_PWR_MGMT_EPLD_VER_MISMATCH: Module [dec] Pwr Mgmt Epld 
(Version-[dec]) needs to be upgraded 

Explanation    Using a wrong version of Epld version can result in unexplainable behaviour

Recommended Action    Upgrade Power Managment EPLD

Error Message     PLATFORM-2-PFM_STDBY_POWERUP_FAIL: standby supervisor failed to 
powerup 

Explanation    Standby supervisor failed to powerup.

Recommended Action    Try to replace the standby supervisor.

Error Message     PLATFORM-2-PFM_SYSTEM_RESET_TRIGGER: System restart due to [chars] 
policy trigger 

Explanation    Policy/trigger initiated a system reload

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_SYSTEM_RESET: Manual system restart from Command Line 
Interface 

Explanation    User initiated a system reload from the CLI

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_SYSTEM_SHUTDOWN_TRIGGER: System shutdown due to 
[chars] policy trigger 

Explanation    Policy/trigger initiated a system shutdown

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PFM_XBAR_RESET: Manual restart of Xbar [dec] from Command 
Line Interface 

Explanation    User initiated a xbar reload from the CLI

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-2-PLUGIN_ABSENT: Module in slot[dec] (sw_card_id=[dec]) has 
missing plugin 

Explanation    Plugin not loaded, The LC cannot be poweredup

Recommended Action    Load the associated plugin

Error Message     PLATFORM-2-PS_ABSENT: Power supply [dec] is absent/shutdown, 
ps-redundancy might be affected 

Explanation    Power Supply is absent.

Recommended Action    No action is required.

Error Message     PLATFORM-2-PS_AC_IN_MISSING: Power supply [dec] present but all AC 
inputs are not connected, ac-redundancy might be affected

Explanation    Power Supply is present but not at full capacity.

Recommended Action    No action is required.

Error Message     PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its 
capacity. possibly due to power cable removal/insertion (Serial number [chars]) 

Explanation    Detected power supply capacity change.

Recommended Action    Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing 
capacity. It is recommended to have same capacity for both powersupplies otherwise 
it may cause service disruptions 

Explanation    Detected a power supply that has differing capacity than an the otherpower supply.

Recommended Action    Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_DETECT: Power supply [dec] detected but shutdown 
(Serial number [chars]) 

Explanation    Power Supply is detected but shutdown.

Recommended Action    Please perform a 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_FAIL: Power supply [dec] failed or shut down (Serial 
number [chars]) 

Explanation    Power Supply has failed or has been shutdown

Recommended Action    Please perform a 'show environment power' and 'show platform internal info' to collect more information. Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.

Error Message     PLATFORM-2-PS_FANFAIL: Fan in Power supply [dec] failed 

Explanation    Fan module in the Power Supply has failed

Recommended Action    Please perform a 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_FANOK: Fan in Power supply [dec] ok 

Explanation    Fan module in the Power Supply is ok.

Recommended Action    No action is required.

Error Message     PLATFORM-2-PS_MISMATCH: Detected power supply [chars]. This reduces 
the redundant power available to the system and can cause service disruptions 
(Serial number [chars]) 

Explanation    Detected a new power supply that has reduced capacity than an existing power supply.

Recommended Action    Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_OK: Power supply [dec] ok (Serial number [chars]) 

Explanation    Power Supply is ok.

Recommended Action    No action is required.

Error Message     PLATFORM-2-PS_RED_MODE_CHG: Power supply redundancy mode changed to 
[chars] 

Explanation    Power supply redundancy mode changed notification

Recommended Action    Please perform a 'show environment power' and 'show platform internal info' to collect more information.

Error Message     PLATFORM-2-PS_REMOVE_LAST: Unexpected removal of last power supply 
[dec]. (Serial number [chars]) 

Explanation    Unexpected removal the only power supply in the system.

Recommended Action    Power supply unit may be faulty. Contact CISCO to replace the unit.

Error Message     PLATFORM-2-PS_REMOVE: Power supply [dec] removed (Serial number 
[chars]) 

Explanation    Power Supply is removed.

Recommended Action    No action is required.

Error Message     PLATFORM-2-PS_UNKNOWN: Detected an unknown power supply [dec] for 
CISCO Multilayer Switch (Serial number [chars]) 

Explanation    Unable to determine power supply type. Default power supply types will be assumed.

Recommended Action    Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.

Error Message     PLATFORM-2-PS_UNSUPPORTED: Detected an unsupported power supply [dec] 
[chars] for CISCO Multilayer Switch (Serial number [chars]) 

Explanation    This power supply is not supported for the CISCO Multilayer Switches.

Recommended Action    Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.

Error Message     PLATFORM-2-SYS_IDPROMBAD_RECOVER_FAIL: Chassis IDPROM [dec] data 
re-initialization Un-successful. Data is invalid 

Explanation    Chassis IDPROM [decimal digit] re-initialization was unsuccessful. Data is invalid.

Recommended Action    Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and collect more information.

Error Message     PLATFORM-2-SYS_IDPROMBAD_RECOVER_PASS: Chassis IDPROM [dec] data 
re-initialized successfully 

Explanation    Chassis IDPROM [decimal digit] invalid data was succesfully re-initialized to valid.

Recommended Action    Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and verify the information.

Error Message     PLATFORM-2-SYS_IDPROMBAD: Chassis IDPROM [dec] data invalid 

Explanation    Chassis IDPROM [decimal digit] contains invalid data.

Recommended Action    Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and collect more information.

Error Message     PLATFORM-2-XBAR_DETECT: Xbar [dec] detected (Serial number [chars]) 

Explanation    A new xbar in slot [decimal digit] is detected.

Recommended Action    No action is required.

Error Message     PLATFORM-2-XBAR_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Xbar [dec] 
will not be powered up (Serial number [chars]) 

Explanation    The xbar can not be powered up because both ejectors are open

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-2-XBAR_REMOVE: Xbar [dec] removed (Serial number [chars]) 

Explanation    The xbar in slot [decimal digit] has been removed.

Recommended Action    No action is required.

PLATFORM-3

Error Message     PLATFORM-3-EJECTOR_STAT_CHANGED: Ejectors' status in slot [dec] has 
changed, [chars] Ejector is [chars], [chars] Ejector is [chars]

Explanation    Ejector status has changed

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     PLATFORM-3-MOD_BRINGUP_MULTI_LIMIT: Giving up after multiple attempts 
were made to bring up the Module [dec], (Serial number [chars]) 

Explanation    The module can not be powered up even after three attempts

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-3-MOD_PWRFAIL_MULTI: Module [dec] failed to power up 
multiple times (Serial number [chars]) 

Explanation    The module can not be powered up even after three attempts

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-3-PFM_ERROR: [chars] 

Explanation    Platform Error

Recommended Action    No action is required.

Error Message     PLATFORM-3-XBAR_BRINGUP_MULTI_LIMIT: Giving up after multiple 
attempts were made to bring up the Xbar [dec], (Serial number [chars]) 

Explanation    The module can not be powered up even after three attempts

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contXBA ents to collect more information.

Error Message     PLATFORM-3-XBAR_PWRFAIL_MULTI: Xbar [dec] failed to power up multiple 
times (Serial number [chars]) 

Explanation    The xbar can not be powered up even after three attempts

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-3-XBAR_PWRFAIL: Xbar [dec] failed to power up (Serial number 
[chars]) 

Explanation    The xbar in slot [decimal digit] failed to power up

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and to collect more information.

Error Message     PLATFORM-3-XBAR_PWRIDPROMFAIL: Xbar [dec] failed to power up due to 
IDPROM read error 

Explanation    The xbar can not be powered up due to IDPROM read error

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

Error Message     PLATFORM-3-XBAR_PWRIDPROM_SW_CARD_ID_UNKNOWN: Xbar [dec] failed to 
power up. (Unknown card. Could not get software-card-id) 

Explanation    The xbar can not be powered up due to missing SWID in core-plugin for this CARDID

Recommended Action    Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.

PLATFORM-4

Error Message     PLATFORM-4-MOD_TEMPFAIL: [chars] temperature sensor [dec] failed 

Explanation    Module in slot [decimal digit] contains a faulty temperature sensor.

Recommended Action    Please perform a 'show env temperature' to collect more information.

Error Message     PLATFORM-4-PFM_FAN_FLTR_STATUS: Fan Filter status: [chars] 

Explanation    Fan Filter status: Present/Absent

Recommended Action    Please perform a 'show platform internal info.

Error Message     PLATFORM-4-PFM_PS_RED_MODE_CHG: Power redundancy mode changed to 
[chars] 

Explanation    Power redundancy mode changed

Recommended Action    Please perform a 'show platform internal info.

Error Message     PLATFORM-4-PFM_WARNING: [chars] 

Explanation    Platform Warning

Recommended Action    No action is required.

PLATFORM-5

Error Message     PLATFORM-5-FAN_DETECT: Fan module [dec] (Serial number [chars]) 
[chars] detected 

Explanation    Fan module is detected

Recommended Action    No action is required.

Error Message     PLATFORM-5-FAN_STATUS: Fan module [dec] (Serial number [chars]) 
[chars] current-status is [chars] 

Explanation    Fan module changed status

Recommended Action    No action is required.

Error Message     PLATFORM-5-MOD_STATUS: [chars] current-status is [chars] 

Explanation    Module in slot [decimal digit] changed status.

Recommended Action    No action is required.

Error Message     PLATFORM-5-PFM_NOTICE: [chars] 

Explanation    Platform Notice

Recommended Action    No action is required.

Error Message     PLATFORM-5-PS_FOUND: Power supply [dec] found (Serial number [chars]) 

Explanation    Power Supply is detected.

Recommended Action    No action is required.

Error Message     PLATFORM-5-PS_STATUS: PowerSupply [dec] current-status is [chars] 
[chars] 

Explanation    Module in slot [decimal digit] changed status.

Recommended Action    No action is required.

Error Message     PLATFORM-5-XBAR_PWRDN: Xbar [dec] powered down (Serial number 
[chars]) 

Explanation    The xbar in slot [decimal digit] is powered down.

Recommended Action    Please perform a 'show module xbar', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors.

Error Message     PLATFORM-5-XBAR_PWRUP: Xbar [dec] powered up (Serial number [chars]) 

Explanation    The xbar in slot [decimal digit] is powered up.

Recommended Action    No action is required.

PLATFORM-6

Error Message     PLATFORM-6-PFM_INFO: [chars] 

Explanation    Platform Info

Recommended Action    No action is required.

PLATFORM-7

Error Message     PLATFORM-7-PFM_CLOCK_UPD_FAIL: Clock update failed due to 
context-switch delay of [dec] msec 

Explanation    System shutdown in [decimal digit] seconds.

Recommended Action    Please perform a 'show env temperature' to collect more information.

PLOG_SUP Messages

This section contains the PLOG_SUP messages.

PLOG_SUP-4

Error Message    PLOG_SUP-4-PLOG_SUP_EXIT: Persistent Logger encountered an error 
[dec]. 

Explanation    Persistent Logger encountered an error

Recommended Action    No action is required.

PLOG Messages

This section contains the PLOG messages.

PLOG-4

Error Message    PLOG-4-PLOG_LC_EXIT: Persistent Logger encountered an error [dec] 

Explanation    Persistent Logger encountered an error

Recommended Action    No action is required.

POLICY_ENGINE Messages

This section contains the POLICY_ENGINE messages.

POLICY_ENGINE-5

Error Message    POLICY_ENGINE-5-POLICY_ACTIVATE_EVENT: [chars] 

Explanation    Policy is activated first time by a security-profile

Recommended Action    No action is required.

Error Message     POLICY_ENGINE-5-POLICY_COMMIT_EVENT: [chars] 

Explanation    Policy-Engine updated with up-to-date policy configuration

Recommended Action    No action is required.

Error Message     POLICY_ENGINE-5-POLICY_DEACTIVATE_EVENT: [chars] 

Explanation    Policy is de-activated, as it is no longer referenced by any security-profile

Recommended Action    No action is required.

POLICY_ENGINE-6

Error Message     POLICY_ENGINE-6-POLICY_LOOKUP_EVENT: [chars] 

Explanation    Policy Lookup event, Policy Evaluation information

Recommended Action    No action is required.

PORT-CHANNEL Messages

This section contains the PORT-CHANNEL messages.

PORT-CHANNEL-1

Error Message    PORT-CHANNEL-1-LC_CFG_FAILURE: configuring module [dec] failed 
[[chars]] 

Explanation    Module configuration failed

Recommended Action    Module will be automatically reset

Error Message     PORT-CHANNEL-1-MALLOC_FAILED: cannot allocate memory (size [dec]) 

Explanation    No enough memory

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-1-MAP_PARAM_FAILURE: mapping parameter failed for 
[chars] [[chars]] 

Explanation    Parameter mapping failed

Recommended Action    Specified service is misbehaving; check its status

Error Message     PORT-CHANNEL-1-MCAST_SEND_FAILURE: failed to send multicast [chars]: 
[chars] 

Explanation    Failed to send a multicast message to all modules, usually because some module went down

Recommended Action    Run show port-channel consistency to check consistency

PORT-CHANNEL-2

Error Message     PORT-CHANNEL-2-AUTO_CREATE_DISABLED: [chars] has been deprecated; 
[chars] [chars] 

Explanation    Auto create port-channel is deprecated and disabled

Recommended Action    Convert the auto created channel to presistent by doing port-channel <n> persistent

Error Message     PORT-CHANNEL-2-RESET_MODULE: reset module [dec] for not responding or 
returning error 

Explanation    A module is reset for not responding or returning error

Recommended Action    No action is required.

PORT-CHANNEL-3

Error Message     PORT-CHANNEL-3-COMPAT_CHECK_FAILURE: [chars] is not compatible 

Explanation    Compatibility check failed when adding ports to port-channel

Recommended Action    Make sure the compatibility parameters are consistent while adding ports to port-channel, or use force option

Error Message     PORT-CHANNEL-3-GENERAL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-LACP_ERROR: [chars] 

Explanation    LACP error

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-LC_CFG_TIMEOUT_ENTRY_PORT_ERR_DISABLE: Failed to send 
LC config due to timeout, Port [chars] Err disabled 

Explanation    Failed to send a lc_config message

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-LC_CFG_UCAST_FAILED_PORT_ERR_DISABLE: Failed to send 
LC config unicast msg, Port [chars] Err disabled 

Explanation    Failed to send a lc_config unicast message

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-LC_CFG_UCAST_SEND_FAILURE: Failed to send LC config 
Unicast msg to slot [dec] node [hex] sap [dec]: [chars]. Resetting LineCard 

Explanation    Failed to send a lc_config unicast message

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: 
[chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-PORT_CHANNEL_NOT_FOUND: [chars] is not found 

Explanation    Cannot find port-channel in its database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-3-TIMEOUT: timed out after [dec] seconds [type [chars], 
state [chars]] 

Explanation    Some operation timed out

Recommended Action    Run show port-channel consistency to check all module connectivity and consistency

PORT-CHANNEL-4

Error Message     PORT-CHANNEL-4-PORT_CFG_DELETED: [chars] removed from [chars] 

Explanation    Port is removed from a port-channel because different module was inserted or module config purged

Recommended Action    You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.

Error Message     PORT-CHANNEL-4-PORT_INDIVIDUAL: port [chars] is operationally 
individual 

Explanation    The port is operating as an individual link even though it is locally or remotely configured to be part of a port channel

Recommended Action    Check the configuration of the port locally and remotely to ensure that it can operate as part of a port channel

Error Message     PORT-CHANNEL-4-PORT_NOT_FOUND: port [chars] is not part of 
port-channel 

Explanation    Cannot find the port in port-channel database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-4-RACE_WARN: [chars] 

Explanation    Warning of possible race condition

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-4-UNEXPECTED_RESPONSE: unexpected response [chars] from 
[chars] 

Explanation    Received an unexpected response and discarded

Recommended Action    No action is required.

PORT-CHANNEL-5

Error Message     PORT-CHANNEL-5-AUTO_CREATE_FAILURE: [chars] [chars] 

Explanation    Auto create process on the port failed

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-CREATED: [chars] created 

Explanation    A port-channel is created

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-DELETED: [chars] deleted 

Explanation    A port-channel is deleted

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-FOP_CHANGED: [chars]: first operational port changed 
from [chars] to [chars] 

Explanation    The first operational port in a port-channel is changed

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-MAX_CHANNEL_DISALLOWED: Module failed to come online 
because port channel interface <port-channel number> greater than [dec] is present 

Explanation    The port-channel number configured on the switch is larger than 128

Recommended Action    Delete the set of port channel interface <port-channel interface> which is greater than 128

Error Message     PORT-CHANNEL-5-PORT_ADDED: [chars] added to [chars] 

Explanation    Ports are added to a port-channel

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-PORT_DOWN: [chars]: [chars] is down 

Explanation    Port goes down in a port-channel

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-PORT_REMOVED: [chars] removed from [chars] 

Explanation    Ports are removed from a port-channel

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-5-PORT_UP: [chars]: [chars] is up 

Explanation    Port comes up in a port-channel

Recommended Action    No action is required.

PORT-CHANNEL-6

Error Message     PORT-CHANNEL-6-RESYNC: resyncing [chars] with all modules 

Explanation    Resync modules with sup after an error or switchover

Recommended Action    No action is required.

PORT-CHANNEL-7

Error Message     PORT-CHANNEL-7-GSYNC_DONE: global synchronization is done 

Explanation    Port-channel manager finished global synchronization

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-GSYNC_REQ: requesting global synchronization 

Explanation    Port-channel manager requested a global synchronization from active sup

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-START_ACTIVE: started in active mode 

Explanation    Port-channel manager started in active mode

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-START_DEFAULT: started with default configuration 

Explanation    Port-channel manager started with default configuration

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-START_STANDBY: started in standby mode 

Explanation    Port-channel manager started in standby mode

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-START_STATEFUL: started statefully 

Explanation    Port-channel manager started with running configuration

Recommended Action    No action is required.

Error Message     PORT-CHANNEL-7-START_STATELESS: started statelessly 

Explanation    Port-channel manager started with startup configuration

Recommended Action    No action is required.

PORT-PROFILE Messages

This section contains the PORT-PROFILE messages.

PORT-PROFILE-2

Error Message    PORT-PROFILE-2-IF_REFRESH_FAILED: Interface Database Refresh failed 
for [chars] 

Explanation    Interface Database Refresh failed

Recommended Action    No action is required.

Error Message     PORT-PROFILE-2-INTERFACE_CMD_FAILURE: Inherit of port-profile [chars] 
on [chars] has failed with reason: [chars] 

Explanation    Executing specific cmd on interface failed

Recommended Action    No action is required.

Error Message     PORT-PROFILE-2-INTERFACE_QUARANTINED: Interface [chars] has been 
quarantined due to [chars] 

Explanation    Interface has been quarantined

Recommended Action    No action is required.

PORT-PROFILE-3

Error Message     PORT-PROFILE-3-ALLOC_FAILED: Failed in File:[chars] Line:[dec] for 
type [dec] size [dec] 

Explanation    SDM process could not allocate heap memory in File:[chars], at line:[dec], for memory-type:[dec] of Size:[dec]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-ASSERTION_FAILED: Failed in File:[chars] Line:[dec] 

Explanation    PPM Process assertion failed in File:[chars], at line:[dec]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-CREATE_IF_FAILED: Running-config collection Failed for 
intf range [chars] 

Explanation    Running-config collection failed for :[chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-IF_APPLY_FAILED: Config Apply Failed 

Explanation    Config Apply Failed

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-INTERFACE_NO_SHUTDOWN_FAILED: Interface no shutdown 
failed for [chars] after profile re-inherit 

Explanation    Interface could not be unshut after profile re-inherit

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-INTERFACE_SHUTDOWN_FAILED: Interface shutdown failed 
for [chars] after failure to apply commands 

Explanation    Interface could not be shutdown after failure to apply commands

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_CREATE_FAILED: Port-profile [chars] creattion 
failed with error [chars] 

Explanation    Port-profile:[chars] creation failed with [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_DEINHERIT_FAILED: Port-profile [chars] 
de-inherit failed with error [chars] on [chars]

Explanation    Port-profile:[chars] de-inherit failed with [:chars] on [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_DELETE_FAILED: Port-profile [chars] is 
deletion failed with error [chars] 

Explanation    Port-profile:[chars] deletion failed with [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_DISABLE_FAILED: Port-profile [chars] disable 
failed with error [chars] 

Explanation    Port-profile:[chars] disable failed with [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_ENABLE_FAILED: Port-profile [chars] enable 
failed with error [chars] 

Explanation    Port-profile:[chars] enable failed with [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-3-PROFILE_INHERIT_FAILED: Port-profile [chars] inherit 
failed with error [chars] on [chars]

Explanation    Port-profile:[chars] inherit failed with [:chars] on [:chars]

Recommended Action    No action is required.

PORT-PROFILE-6

Error Message     PORT-PROFILE-6-PROFILE_CREATED: Port-profile [chars] is created 
successfully 

Explanation    Port-profile:[chars] is created

Recommended Action    No action is required.

Error Message     PORT-PROFILE-6-PROFILE_DEINHERITED: Port-profile [chars] is 
de-inherited successfully on [chars]

Explanation    Port-profile:[chars] is de-inherited on [:chars]

Recommended Action    No action is required.

Error Message     PORT-PROFILE-6-PROFILE_DELETED: Port-profile [chars] is deleted 
successfully 

Explanation    Port-profile:[chars] is deleted

Recommended Action    No action is required.

Error Message     PORT-PROFILE-6-PROFILE_DISABLED: Port-profile [chars] is disabled 
successfully 

Explanation    Port-profile:[chars] is disabled

Recommended Action    No action is required.

Error Message     PORT-PROFILE-6-PROFILE_ENABLED: Port-profile [chars] is enabled 
successfully 

Explanation    Port-profile:[chars] is enabled

Recommended Action    No action is required.

Error Message     PORT-PROFILE-6-PROFILE_INHERITED: Port-profile [chars] is inherited 
successfully on [chars]

Explanation    Port-profile:[chars] is inherited on [:chars]

Recommended Action    No action is required.

PORT-RESOURCES Messages

This section contains the PORT-RESOURCES messages.

PORT-RESOURCES-3

Error Message    PORT-RESOURCES-3-PRM_MSG_SEND_FAILURE: failed to send [chars] to sap 
[dec]: [chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

PORT-RESOURCES-5

Error Message     PORT-RESOURCES-5-INVALID_PORT_ACTIV_PKG_LICENSE_FILE_INSTALLED: 
Invalid on demand port activation license file is installed for module [dec] 
(number of port licenses = [dec]) 

Explanation    Interfaces may not acquire port activation licenes during installation

Recommended Action    Install a valid port activation license file

PORT-SECURITY Messages

This section contains the PORT-SECURITY messages.

PORT-SECURITY-2

Error Message    PORT-SECURITY-2-ALLOC_FAILED: Memory allocation failed for size:[dec] 
for [chars] 

Explanation    Memory allocation failed for size [dec] for [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-2-FEATURE_DISABLED: Feature [chars] disabled due to 
[chars] 

Explanation    Feature [chars] is unavailable and will be disabled now

Recommended Action    Please install the correct license and reenable

PORT-SECURITY-3

Error Message     PORT-SECURITY-3-BINDING_CONFLICT: [chars] 

Explanation    An already logged in device is in conflict with the PSM active binding configurations. [chars] indicates the WWN of the login entity, interface

Recommended Action    For port-security, the auto-learn feature can be used with activation to prevent this. This violating device or switch will be logged out

Error Message     PORT-SECURITY-3-BINDING_VIOLATION: [chars] 

Explanation    A login happend that violates PSM binding configurations [chars] indicates the WWN of the login entity

Recommended Action    Only entries in the activated database of PSM can login. Change the config and activate it again

Error Message     PORT-SECURITY-3-CFS_NOTIF_ERR: [chars] 

Explanation    An error occurred during the processing of a CFS notification. [chars] indicates the actual cause for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-DB_ERR: [chars] 

Explanation    An error occurred during an PSM database operation. [chars] indicates the reason for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-EFMD_FC2_OPER_FAILED: [chars] 

Explanation    EFMD fc2 operation failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-EFMD_INIT_FAILED: [chars] 

Explanation    EFMD init failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-EFMD_MERGE_UNKNOWN_FORMAT: [chars] 

Explanation    Received a corrupted EFMD Request Packet

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-INIT_FAIL: [chars] 

Explanation    An error happened during PSM Initialization. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-LEARNT_BINDING_CONFLICT: [chars] 

Explanation    An already logged in device that is learnt during activation is in conflict with the PSM active binding configurations. [chars] indicates the WWN of the login entity, interface

Recommended Action    Copy the active-db to config-db and reactivate. Not doing so could result in unexpected login rejects later on that interface.

Error Message     PORT-SECURITY-3-MTS_ERR: [chars] 

Explanation    An error occurred in processing of an MTS message. [chars] indicates the error that occurred

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-PSS_ERR: [chars] 

Explanation    An error occurred during an PSM PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PORT-SECURITY-3-PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

PORT-SECURITY-4

Error Message     PORT-SECURITY-4-ACTIVATION_FAIL: [chars] 

Explanation    Activation of bindings failed due to [chars]

Recommended Action    Correct the error and reactivate it again

PORT-SECURITY-6

Error Message     PORT-SECURITY-6-INFO: [chars] 

Explanation    An event happend that affects PSM. [chars] indicates the event

Recommended Action    No action is required.

PORT Messages

This section contains the PORT messages.

PORT-2

Error Message    PORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error 
disabled) 

Explanation    The interface encountered an error while configuring it

Recommended Action    Collect more information about failed interface using command 'show port internal all interface [char]'. In most cases, you can recover using following commands 'config terminal', 'interface [char]', 'shutdown', 'no shutdown' on the interface or removing and re-inserting the fibre optic cable

Error Message     PORT-2-IF_DOWN_LINK_FAILURE: Interface [chars] is down (Link failure) 

Explanation    The physical link has gone down

Recommended Action    Ensure that the cable is connected and the remote end is not shut down

PORT-3

Error Message     PORT-3-IF_SFP_ALARM: Interface [chars], [chars] 

Explanation    There was an alarm on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     PORT-3-IF_TRANSCEIVER_READ_ERROR: Transceiver read error for 
interface [chars] 

Explanation    Transceiver eeprom read failed

Recommended Action    Remove and insert the SFP back again. If the problem persists check if the transceiver is supported using the command: show interface transceiver. Please contact customer support to resolve the condition

Error Message     PORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver for interface [chars] 
is not supported 

Explanation    Transceiver is not from an authorized vendor

Recommended Action    This command will determine the transceiver being used: show interface transceiver. Please contact customer support for a list of authorized transceiver vendors

PORT-4

Error Message     PORT-4-IF_SFP_CLK_RATE_ERROR: SFP clock rate error for interface 
[chars] 

Explanation    SFP clock rate mismatch/failed

Recommended Action    Remove the SFP and insert a new one with a different frequency type. If the problem persists check if the transceiver is supported using the command: show interface transceiver. Please contact customer support to resolve the condition

Error Message     PORT-4-IF_SFP_WARNING: Interface [chars], [chars] 

Explanation    There was an warning on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     PORT-4-IF_TRUSTSEC_VIOLATION: Interface [chars] encountered port 
security violation 

Explanation    The port has detected port security violation

Recommended Action    Check port security configs on interface

PORT-5

Error Message     PORT-5-EC_DISABLED_AS_LICENSE_NOT_PRESENT: Extended credit feature 
has been disabled as Enterprise Package license could not be checked out 

Explanation    The Enterprise Package license is not available, so the extened credit feature has been disabled even though it was present in startup config

Recommended Action    Install the Enterprise Package license and re-enable the extended credit feature

Error Message     PORT-5-IF_BRINGUP_ALLOWED_FCOT_CHECKSUM_ERR: Interface [chars] is 
allowed to come up even with SFP checksum error 

Explanation    SFP checksum on this interface failed

Recommended Action    Try to replace the SFP on this interface

Error Message     PORT-5-IF_BRINGUP_FAILED_ALL_ZERO_PEER_WWN_RCVD: Interface [chars], 
is not allowed to come up (received as all zeros wwn from peer 

Explanation    Check peer interface configuration

Recommended Action    No action is required.

Error Message     PORT-5-IF_BRINGUP_NOT_ALLOWED_PORT_CONFIG_FAILURE: Interface [chars] 
is not allowed to be operational due to port config failure for reason: [chars] 
([hex]) 

Explanation    Check interface configuration

Recommended Action    Try to change the configuration on the interface with the current available hardware capability

Error Message     PORT-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is down 
(Administratively down) 

Explanation    Interface has been configured to be administratively down

Recommended Action    Perform the following commands to bring up the interface: 'config terminal', 'interface [char]', 'no shutdown'

Error Message     PORT-5-IF_DOWN_BIT_ERR_RT_THRES_EXCEEDED: Interface [chars] is down 
(Error disabled - bit error rate too high) 

Explanation    The port has detected too high bit error rate in frames received from attached device

Recommended Action    Check the attached device; replace it if needed

Error Message     PORT-5-IF_DOWN_BUNDLE_MISCFG: Interface [chars] is down (Isolation 
due to channel mis-configuration on local or remote switch) 

Explanation    One port across a link is part of a PortChannel while the other is not.

Recommended Action    While adding or deleting a member port from a PortChannel, both ports across the link should be added/deleted. No operation should be performed on either ports until they are both added/deleted.

Error Message     PORT-5-IF_DOWN_CFG_CHANGE: Interface [chars] is down(Config change) 

Explanation    FCIP interface temporarily down due to reconfiguration

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_CHANNEL_ADMIN_DOWN: Interface [chars] is down (Channel 
admin down) 

Explanation    This interface belongs to a PortChannel and the PortChannel is configured to be administratively down

Recommended Action    Perform the following commands on the PortChannel interface to which it belongs to bring the interface up: 'config terminal', 'interface [char]', 'shutdown', 'no shutdown'

Error Message     PORT-5-IF_DOWN_CHANNEL_MEMBERSHIP_UPDATE_IN_PROGRESS: Interface 
[chars] is down (Channel membership update in progress) 

Explanation    The interface belongs to a PortChannel and a configuration is being attempted on the interface while there is a configuration in progress on the PortChannel

Recommended Action    Retry the configuration again

Error Message     PORT-5-IF_DOWN_DENIED_DUE_TO_PORT_BINDING: Interface [chars] is 
down(Suspended due to port binding) 

Explanation    The F port is suspended due to being denied by port binding.

Recommended Action    Please check the port binding database to allow the host port to log in.

Error Message     PORT-5-IF_DOWN_DOMAIN_ADDR_ASSIGN_FAILURE_ISOLATION: Interface 
[chars] is down (Isolation due to domain id assignment failure) 

Explanation    Isolated due to a failure while assigning a domain

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DOMAIN_INVALID_RCF_RECEIVED: Interface [chars] is down 
(Isolation due to invalid fabric reconfiguration) 

Explanation    Invalid RCF received

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED: Interface [chars] is down 
(Isolation due to domain manager disabled) 

Explanation    Isolated due to domain manager being disabled

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE: Interface [chars] 
is down (Isolation due to domain manager other side not responding) 

Explanation    Remote end domain manager not responding

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DOMAIN_NOT_ALLOWED_ISOLATION: Interface [chars] is 
isolated (domain not allowed) 

Explanation    There aren't enough allowed domains to merge the VSANs across the link.

Recommended Action    Ensure that all assigned domain id's are in the configured allowed domains on both sides of the link.

Error Message     PORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED: Interface [chars] 
is down (Isolation due to domain other side eport isolated) 

Explanation    Isolating this interface due to the remote end being isolated

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION: Interface [chars] is down 
(Isolation due to domain overlap) 

Explanation    Isolated due to domain overlap

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_DPVM_VSAN_NOT_FOUND: Interface [chars] is down 
(dynamic vsan not present) 

Explanation    The specified dynamic vsan is not configured on this switch

Recommended Action    Configure the dynamic vsan.

Error Message     PORT-5-IF_DOWN_DPVM_VSAN_SUSPENDED: Interface [chars] is down 
(dynamic vsan in suspended state) 

Explanation    The specified dynamic vsan is in suspended state

Recommended Action    Un-suspend the dynamic vsan.

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_CLASSF_PARAM_ERR: Interface 
[chars] is down (Isolation due to ELP failure: class F param error) 

Explanation    ELP failed on the interface due to class F param error

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_CLASSN_PARAM_ERR: Interface 
[chars] is down (Isolation due to ELP failure: class N param error) 

Explanation    ELP failed on the interface due to class N param error

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_PAYLOAD_SIZE: Interface 
[chars] is down (Isolation due to ELP failure: invalid payload size) 

Explanation    ELP failed on the interface due to invalid payload size

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_PORT_NAME: Interface 
[chars] is down (Isolation due to ELP failure: invalid port name) 

Explanation    ELP failed on the interface due to invalid port name

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_SWITCH_NAME: Interface 
[chars] is down (Isolation due to ELP failure: invalid switch name) 

Explanation    ELP failed on the interface due to invalid switch name

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_TX_BBCREDIT: Interface 
[chars] is down (Isolation due to ELP failure: loopback detected) 

Explanation    ELP failed on the interface due to loopback connection detected

Recommended Action    Connect to a port on another switch and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_LOOPBACK_DETECTED: Interface 
[chars] is down (Isolation due to ELP failure: invalid transmit B2B credit) 

Explanation    ELP failed on the interface due to invalid transmit B2B credit

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_RATOV_EDTOV_MISMATCH: Interface 
[chars] is down (Isolation due to ELP failure: R_A_TOV or E_D_TOV mismatch) 

Explanation    ELP failed on the interface due to R_A_TOV or E_D_TOV mismatch

Recommended Action    Configure R_A_TOV and E_D_TOV values correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_REVISION_MISMATCH: Interface 
[chars] is down (Isolation due to ELP failure: revision mismatch) 

Explanation    ELP failed on the interface due to revision mismatch

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_CODE: 
Interface [chars] is down (Isolation due to ELP failure: invalid flow control code) 

Explanation    ELP failed on the interface due to invalid flow control code

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_PARAM: 
Interface [chars] is down (Isolation due to ELP failure: invalid flow control 
param) 

Explanation    ELP failed on the interface due to invalid flow control param

Recommended Action    Configure the attached switchport correctly and try again

Error Message     PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ELP failure) 

Explanation    ELP failed on the interface

Recommended Action    Check the output of 'show port internal info' in the 'ELP failure reason' field

Error Message     PORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error Disabled 
- EPP Failure) 

Explanation    Trunk protocol failed

Recommended Action    'show port internal event-history msgs' will indicate the trunk protocol exchanges to determine why it failed

Error Message     PORT-5-IF_DOWN_ESC_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ESC failure) 

Explanation    ESC failed on the interface

Recommended Action    Check the output of 'show port internal event-history' to determine the ESC protocol exchanges to determine how it failed

Error Message     PORT-5-IF_DOWN_ETH_IF_DOWN: Interface [chars] is down(Tunnel port src 
interface down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected, the interface is administratively enabled

Error Message     PORT-5-IF_DOWN_ETH_LINK_DOWN: Interface [chars] is down(Tunnel port 
src interface link down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected and the remote end is also active

Error Message     PORT-5-IF_DOWN_FABRIC_BIND_FAILURE: Interface [chars] is 
down(Isolation due to fabric bind failure) 

Explanation    Fabric binding failed on this port.

Recommended Action    Please check the fabric binding database to ensure that the remote port is allowed to connect to this port

Error Message     PORT-5-IF_DOWN_FCOT_NOT_PRESENT: Interface [chars] is down (FCOT not 
present) 

Explanation    The FCOT has been removed

Recommended Action    Insert an FCOT

Error Message     PORT-5-IF_DOWN_FCOT_VENDOR_NOT_SUPPORTED: Interface [chars] is down 
(Error disabled - FCOT vendor not supported) 

Explanation    FCOT inserted is not a supported one

Recommended Action    Please contact customer support for a list of authorized transceiver vendors

Error Message     PORT-5-IF_DOWN_FCSP_AUTHENT_FAILURE: Interface [chars] is down (FC-SP 
authentication failure) 

Explanation    The port failed FC-SP authentication with its peer.

Recommended Action    Please check the FC-SP configuration.

Error Message     PORT-5-IF_DOWN_FICON_BEING_ENABLED: Interface [chars] is down(FICON 
being enabled) 

Explanation    FICON is being enabled on the port

Recommended Action    Please wait. This might take a while

Error Message     PORT-5-IF_DOWN_FICON_NOT_ENABLED: Interface [chars] is down(Error 
disabled - FICON not enabled) 

Explanation    FICON not enabled on port

Recommended Action    Please enable FICON on port

Error Message     PORT-5-IF_DOWN_FICON_VSAN_DOWN: Interface [chars] is down(FICON vsan 
down) 

Explanation    FICON is being enabled on the port VSAN of this port

Recommended Action    This is an intermediary state, whereby the port VSAN of the port is being enabled to be a FICON VSAN.

Error Message     PORT-5-IF_DOWN_HW_FAILURE: Interface [chars] is down (Hardware 
Failure) 

Explanation    The module's hardware has failed

Recommended Action    Collect more information about failed module using command 'show module internal all module'

Error Message     PORT-5-IF_DOWN_INACTIVE: Interface [chars] is down (Inactive) 

Explanation    The port VSAN has been suspended or deleted

Recommended Action    Assign a new active port VSAN to the interface

Error Message     PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_MODE: Interface [chars] is down 
(Error disabled - Incompatible admin port mode) 

Explanation    The configured mode is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the list of modes supported on this interface

Error Message     PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBBCREDIT: Interface [chars] is 
down (Error disabled - Incompatible admin port rxbbcredit) 

Explanation    The configured receive B2B credit size is not supported

Recommended Action    Get the allowed receive B2B credit size from 'show port internal info'

Error Message     PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBUFSIZE: Interface [chars] is 
down (Error disabled - Incompatible admin port rxbufsize) 

Explanation    The configured receive buffer size is not supported

Recommended Action    Get the allowed receive buffer size from 'show port internal info'

Error Message     PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_SPEED: Interface [chars] is down 
(Error disabled - Incompatible admin port speed) 

Explanation    The configured speed is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the range of speed supported on this interface

Error Message     PORT-5-IF_DOWN_INITIALIZING: Interface [chars] is down (Initializing) 

Explanation    The interface is in the process of coming up

Recommended Action    If the interface is stuck in this state for a while, check the output of 'show port internal event-history' to determine what it is waiting for

Error Message     PORT-5-IF_DOWN_INTERFACE_REMOVED: Interface [chars] is down 
(Interface removed) 

Explanation    Interface removed

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_INVALID_ATTACHMENT: Interface [chars] is down(Invalid 
attachment) 

Explanation    The peer port does not have the compatible security attributes.

Recommended Action    Please ensure that the peer port has compatible security attributes as the local port.

Error Message     PORT-5-IF_DOWN_INVALID_CONFIG: Interface [chars] is down(Error 
disabled - Possible PortChannel misconfiguration) 

Explanation    The local and peer port have a PortChannel membership misconfiguration

Recommended Action    Ensure that both the local and peer ports are either both members of the same PortChannel or are not both part of PortChannel

Error Message     PORT-5-IF_DOWN_INVALID_FABRIC_BINDING: Interface [chars] is 
down(Invalid fabric binding exchange) 

Explanation    Fabric binding failed

Recommended Action    Please check fabric binding database

Error Message     PORT-5-IF_DOWN_LOCALLY_DISRUPTIVE_RECONFIGURATION: Interface [chars] 
is down (fcdomain applied a locally disruptive reconfiguration) 

Explanation    Fcdomain applied a locally disruptive reconfiguration (local domain became invalid

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE: Interface [chars] is down (Diag 
failure) 

Explanation    Diag failed on the interface

Recommended Action    Collect more information about failed interface using command 'attach module' to connect to module

Error Message     PORT-5-IF_DOWN_LOOPBACK_ISOLATION: Interface [chars] is down 
(Isolation due to port loopback to same switch) 

Explanation    The interface is looped back to another interface on the same switch

Recommended Action    Check the connectivity of this interface and ensure that it is connected to another switch

Error Message     PORT-5-IF_DOWN_MODULE_REMOVED: Interface [chars] is down (module 
removed) 

Explanation    Interface is down because the module was removed

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_NONE: Interface [chars] is down (None) 

Explanation    There is no apparent reason the interface is down

Recommended Action    Collect more information about port using command 'show port internal all interface [char]' to determine why it went down

Error Message     PORT-5-IF_DOWN_NON_PARTICIPATING: Interface [chars] is down (Non 
participating) 

Explanation    The loop port has been put into non participating mode

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_NOS_RCVD: Interface [chars] is down (NOS received) 

Explanation    The physical link has gone down

Recommended Action    Ensure that the cable is connected and the remote end is not shut down

Error Message     PORT-5-IF_DOWN_NO_TRUNK_OPER_VSANS_ISOLATION: Interface [chars] is 
down(Isolation due to no common vsans with peer on trunk) 

Explanation    The trunk port is isolated as there are no common VSANs to be brought up with the peer port.

Recommended Action    Please check that there are common VSANs configured and allowed to come up between the ports.

Error Message     PORT-5-IF_DOWN_OFFLINE: Interface [chars] is down (Offline) 

Explanation    The interface has been placed into the offline state

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_OHMS_EXTERNAL_LB_TEST: Interface [chars] is 
down(Loopback test) 

Explanation    Loopback tests

Recommended Action    Please wait. This might take a while

Error Message     PORT-5-IF_DOWN_OLS_RCVD: Interface [chars] is down (OLS received) 

Explanation    The physical link has gone down

Recommended Action    Ensure that the cable is connected and the remote end is not shut down

Error Message     PORT-5-IF_DOWN_PARENT_ADMIN_DOWN: Interface [chars] is down (Parent 
interface down) 

Explanation    Parent interface is down

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_PEER_CLOSE: Interface [chars] is down(TCP conn. closed 
by peer) 

Explanation    The FCIP peer connected to this interface closed the TCP connection

Recommended Action    This command will provide the peer IP address of this FCIP interface: show interface. Check to see why the peer closed the TCP connection

Error Message     PORT-5-IF_DOWN_PEER_RESET: Interface [chars] is down(TCP conn. reset 
by peer) 

Explanation    TCP connection to the FCIP peer got reset

Recommended Action    The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Check to see why the peer reset the TCP connection

Error Message     PORT-5-IF_DOWN_PORT_ACT_LICENSE_NOT_AVAILABLE: Interface [chars] is 
not allowed to come up (port activation license not available 

Explanation    Assign a port activation license to this port or install additional port activation licenses as needed

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_PORT_BIND_FAILURE: Interface [chars] is down(Isolation 
due to port bind failure) 

Explanation    Port binding failed on this port.

Recommended Action    Please check the port binding database to ensure that the remote port is allowed to connect to this port

Error Message     PORT-5-IF_DOWN_PORT_BLOCKED: Interface [chars] is down(Port blocked 
due to FICON) 

Explanation    The port has been blocked by FICON configuration.

Recommended Action    Please unblock the port in FICON configuration.

Error Message     PORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface [chars] is down 
(No operational members) 

Explanation    This is a PortChannel interface and all its members are operationally down

Recommended Action    Enable at least one of the PortChannel's members

Error Message     PORT-5-IF_DOWN_PORT_VSAN_MISMATCH_ISOLATION: Interface [chars] is 
down (Isolation due to port VSAN mismatch) 

Explanation    Isolated due to a mismatch in the configured port VSAN of the local and remote ends

Recommended Action    Configure the port VSAN of the local and remote interfaces to be the same and perform a 'shutdown' and a 'no shutdown'

Error Message     PORT-5-IF_DOWN_RCF_IN_PROGRESS: Interface [chars] is down (RCF in 
progress) 

Explanation    There is an RCF in progress

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface [chars] is down (Port 
software failure) 

Explanation    The software servicing the data path on the port has failed

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_SRC_MOD_NOT_ONLINE: Interface [chars] is down(Tunnel 
source module not online) 

Explanation    Module that has the tunnel source port of this FCIP interface is not fully online

Recommended Action    The module that has the tunnel src port is coming online. Please use show mod to find module status

Error Message     PORT-5-IF_DOWN_SRC_PORT_NOT_BOUND: Interface [chars] is down (Tunnel 
port src interface unbound) 

Explanation    Tunnel port source interface unbound

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_SRC_PORT_REMOVED: Interface [chars] is down(Tunnel src 
port removed) 

Explanation    Tunnel source port of this FCIP interface has been removed

Recommended Action    The src interface with ip address that matches the ip address of the bound entity is removed. This happens normally due to the module on which the src interface exists is removed

Error Message     PORT-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down 
(Suspended due to incompatible mode) 

Explanation    This interface belongs to a PortChannel and operational mode of the interface is different from that of the PortChannel

Recommended Action    Change the mode and the trunking mode of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     PORT-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down 
(Suspended due to incompatible speed) 

Explanation    This interface belongs to a PortChannel and operational speedode of the interface is different from that of the PortChannel

Recommended Action    Change the speed of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     PORT-5-IF_DOWN_SUSPENDED_BY_WWN: Interface [chars] is down (Suspended 
due to incompatible remote switch WWN) 

Explanation    This interface belongs to a PortChannel and remote switch WWN of the interface is different from that of the PortChannel

Recommended Action    Ensure that this interface is connected to the same remote switch as all the other interfaces in the PortChannel

Error Message     PORT-5-IF_DOWN_SUSPENDED: Interface [chars] is down (Suspended) 

Explanation    This interface belongs to a PortChannel and has been suspended to to an error while bringing it up

Recommended Action    In most cases, you can recover using following commands 'config terminal', 'interface [char]', 'shutdown', 'no shutdown' on the interface. If this happens again obtain output of 'show port internal all interface [char]' on the interface

Error Message     PORT-5-IF_DOWN_TCP_KEEP_ALIVE_EXPIRED: Interface [chars] is down(TCP 
conn. closed - Keep alive expired) 

Explanation    TCP session to the FCIP peer got closed due to loss of TCP keep alive

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     PORT-5-IF_DOWN_TCP_MAX_RETRANSMIT: Interface [chars] is down(TCP 
conn. closed - retransmit failure) 

Explanation    Interface is down due to maximum retransmission failure

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     PORT-5-IF_DOWN_TCP_PERSIST_TIMER_EXPIRED: Interface [chars] is 
down(TCP conn. closed - Persist timer expired) 

Explanation    TCP session to the FCIP peer closed because TCP persist timer expired

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     PORT-5-IF_DOWN_TOO_MANY_INTR: Interface [chars] is down (Error 
disabled - too many interrupts) 

Explanation    The port has received too many interrupts in the hardware

Recommended Action    Check the attached device; replace it if needed

Error Message     PORT-5-IF_DOWN_TOO_MANY_INVALID_FLOGIS: Interface [chars] is 
down(Suspended due to too many invalid flogis 

Explanation    The port is suspended due to receiving a large number of invalid FLOGI's.

Recommended Action    Please check the HBA and perform a shut, followed by no shut on the port.

Error Message     PORT-5-IF_DOWN_UPGRADE_IN_PROGRESS: Interface [chars] is down 
(Linecard upgrade in progress) 

Explanation    Upgrade of the linecard software is in progress

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_VIRTUAL_IVR_DOMAIN_OVERLAP_ISOLATION: Interface 
[chars] is down (Isolation due to virtual IVR domain overlap) 

Explanation    Isolated due to virtual IVR domain overlap

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION: Interface [chars] is down 
(Isolation due to vsan mismatch) 

Explanation    This is a trunking interface and the VSANs configured do not match with the VSANs configured on the remote end

Recommended Action    Check the VSANs configured on the local end with the remote end

Error Message     PORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION: Interface [chars] is 
down (Isolation due to zone merge failure) 

Explanation    Isolated due to a failure during zone merge

Recommended Action    No action is required.

Error Message     PORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION: Interface [chars] is 
down (Isolation due to remote zone server not responding) 

Explanation    Isolated due to remote zone server not responding

Recommended Action    No action is required.

Error Message     PORT-5-IF_PORT_GUARD_DOWN: Interface [chars] is down ([chars]) 

Explanation    The interface is down due to port guard configuration

Recommended Action    Perform a shut followed by no shut to bring up the interface

Error Message     PORT-5-IF_PORT_QUIESCE_FAILED: Interface [chars] port quiesce failed 
due to failure reason: [chars] ([hex]) 

Explanation    There may be few packet drops due to this failure

Recommended Action    No action is required.

Error Message     PORT-5-IF_TRUNK_DOWN: Interface [chars], vsan [chars] is down 
([chars]) 

Explanation    Interface [chars] is trunking, VSAN [chars] is down with reason in ()

Recommended Action    The following commands will help determine why this VSAN is down on this interface: show interface, show port internal info interface VSAN, show port internal event-history interface VSAN

Error Message     PORT-5-IF_TRUNK_UP: Interface [chars], vsan [chars] is up 

Explanation    Interface [chars] is trunking, VSAN [chars] is up

Recommended Action    No action is required.

Error Message     PORT-5-IF_UP: Interface [chars] is up [chars] 

Explanation    Interface is up in mode specified, if applicable

Recommended Action    No action is required.

Error Message     PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module [dec] to come 
up for reason: [chars] ([hex]) 

Explanation    Module is not allowed to be operational due to the current system state

Recommended Action    Use command show module <x> recovery-steps and follow the steps described

Error Message     PORT-5-MODULE_INDEX_RESTORE_ERROR: Error in restoring indices for 
module [dec]: reason [chars] ([hex]) 

Explanation    Restore of module index may fail due to overlap of indices

Recommended Action    No action is required.

Error Message     PORT-5-MODULE_UNLIMITED_OSM_SEQ_FAILED: Enable/Disable of unlimited 
oversubscription failed for module [dec] 

Explanation    Interfaces of the module may be in indeterminate state

Recommended Action    Reload the module

PRIVATE_VLAN Messages

This section contains the PRIVATE_VLAN messages.

PRIVATE_VLAN-3

Error Message    PRIVATE_VLAN-3-PVLAN_IN_USE: PVLAN [dec] in use by interface [chars], 
please do no switchport access vlan or no switchport private-vlan host-association 

Explanation    PVLAN in used

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-3-PVLAN_PORT_CONFIG_FAILED: PVLAN Configuratio failed, 
using PVLAN primary vlan [dec] in access port 

Explanation    PVLAN Configuration failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-3-PVLAN_PPM_PORT_CONFIG_FAILED: PVLAN PPM Configuration 
failed, PVLAN vlan error 

Explanation    PVLAN PPM Configuration failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-3-PVLAN_TRUNK_EXCEEDED: Number of mappings on 
private-vlan trunk port limited is [dec] 

Explanation    PVLAN Trunk Exceeded

Recommended Action    No action is required.

PRIVATE_VLAN-5

Error Message     PRIVATE_VLAN-5-PVLAN_ASSOC_DOWN_FAILED: Failed to bring down the 
association between [dec] & [dec] 

Explanation    Association bringdown failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_ASSOC_UP_FAILED: Failed to bring up the 
association between [dec] & [dec] 

Explanation    Association bringup failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_DISABLED: PVLAN Disabled 

Explanation    PVLAN Service Disabled

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_DISABLE_FAILED: Disabling of private-vlan 
failed. Either shutdown these ports or remove them from private-vlan mode: [chars] 

Explanation    Disabling of private-vlan failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_ELTM_MTS_SEND_FAILED: MTS send failed while 
communicating with ELTM. 

Explanation    ELTM MTS send failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_ELTM_TIMED_OUT: ELTM timed out while configuring 
hardware. 

Explanation    ELTM timed out

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_ENABLED: PVLAN Enabled 

Explanation    PVLAN Service Enabled

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_HW_ERROR: Error [hex] occurred for ifindex [hex] 
while programming hardware: [chars] 

Explanation    Hardware Configuration Error

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_PIXM_MTS_SEND_FAILED: MTS send failed while 
communicating with PIXM 

Explanation    PIXM MTS send failed

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_PIXM_TIMED_OUT: PIXM timed out while configuring 
hardware. 

Explanation    PIXM timed out

Recommended Action    No action is required.

Error Message     PRIVATE_VLAN-5-PVLAN_VLANMGR_FAILURE: Cannot restore association 
operational state. Failed to communicate with VLAN manager 

Explanation    Restoring association operational status failed

Recommended Action    No action is required.

PROC_MGR Messages

This section contains the PORC_MGR messages.

PROC_MGR-SLOT#-2

Error Message    PROC_MGR-SLOT#-2-ERR_MSG: [chars] 

Explanation    Process manager error.

Recommended Action    No action is required.

Error Message     PROC_MGR-SLOT#-2-MESG: [chars] 

Explanation    Process manager information.

Recommended Action    Process manager information.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_APP_CRIT_ERROR: ERROR: Critical error 
determined for app ([chars]) status=[dec] signal=[dec] 

Explanation    Application caused critical error.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_APP_EXITED: ERROR: Application ([chars]) 
exited with status=[dec] signal=[dec] 

Explanation    Application exited.

Recommended Action    Check the application.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_COMP_CATASTROPHIC_ERROR: ERROR: Component 
([chars]) caused critical error and linecard will be rebooted 

Explanation    Component caused critical error.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_COMP_CRIT_ERROR: ERROR: Critical error 
determined for component ([chars]) errno=[dec] 

Explanation    Critical error for component.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_COMP_DEP_FAIL: ERROR: Dependency failure - 
Component ([chars]) depends on ([chars]) 

Explanation    Component dependency failure.

Recommended Action    Check whether the component exists.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_COMP_NOT_INSTALLED: ERROR: Component 
([chars]) could not be installed errno=[dec] 

Explanation    Component not installed.

Recommended Action    Check whether the component exists.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_COMP_TIMEOUT: ERROR: Component ([chars]) 
did not exit and time out occurred 

Explanation    Component initialization timed out.

Recommended Action    Check the component.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_MTS_CORE_CLIENT_FAIL: ERROR: MTS message to 
core_client FAILED errno=[dec] 

Explanation    Message to core client failed.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_QUIT: Process manager quitting because: 
[chars] 

Explanation    Process manager quitting.

Recommended Action    No action is required.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_RM_KLM_SCRIPT: Removed: KLM/Script 
[[chars]] in [dec] sec [dec] usec ... 

Explanation    Removed KLM/Script.

Recommended Action    No action is required.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_STOP_PROC: Process [[chars]] exited in 
[dec] sec [dec] usec ... 

Explanation    Process stopped.

Recommended Action    No action is required.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_TERM_TIME: * Termination took [dec] sec 
[dec] usec * 

Explanation    Process manager termination time.

Recommended Action    No action is required.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_UT_PEEK_FAIL: ERROR: Unable to peek on 
utaker queue 

Explanation    Peek at utaker queue failed.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_UT_SEM_ALLOC_FAIL: ERROR:Failed to 
allocate utaker semaphore: [dec] 

Explanation    Utaker semaphore allocation failed.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_UT_SEM_GET_FAIL: ERROR:[chars] [dec]: 
Failed to get utaker semaphore: [dec] 

Explanation    Utaker semaphore get failed.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_UT_SEM_GIVE_FAIL: ERROR:[chars] [dec]: 
Failed to give utaker semaphore: [dec] 

Explanation    Utaker semaphore give failed.

Recommended Action    Restart the linecard.

Error Message     PROC_MGR-SLOT#-2-PROC_MGR_UT_SEM_TAKE_FAIL: ERROR:[chars] [dec]: 
Failed to take utaker semaphore: [dec] 

Explanation    Utaker semaphore take failed.

Recommended Action    Restart the linecard.

PROC_MGR-SLOT#-3

Error Message     PROC_MGR-SLOT#-3-PROC_MGR_ERROR_MSG: [chars] 

Explanation    Process manager error message

Recommended Action    No action is required.

PROC_MGR-SLOT#-4

Error Message     PROC_MGR-SLOT#-4-PROC_MGR_APP_NOT_RESP: ERROR: Process ([chars]) is 
not responding, it will be terminated 

Explanation    Application not sending heartbeat.

Recommended Action    Check the application.

PROC_MGR-SLOT#-6

Error Message     PROC_MGR-SLOT#-6-PROC_MGR_INFO_MSG: [chars] 

Explanation    Process manager info message

Recommended Action    No action is required.

PSS Messages

This section contains the PSS messages.

PSS-0

Error Message    PSS-0-PSS_NO_MORE_PAGES: [chars]: needs more working pages 

Explanation    Service needs more working page buffers

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     PSS-0-PSS_READ_DATA_FAILURE: [chars]: failed to read data to [chars] 
block [dec]: [chars] 

Explanation    PSS cannot read data

Recommended Action    No action is required.

Error Message     PSS-0-PSS_SYNC_DATA_FAILURE: [chars]: failed to sync data to [chars]: 
[chars] 

Explanation    PSS cannot sync data due to filesystem or disk error

Recommended Action    No action is required.

Error Message     PSS-0-PSS_SYNC_LOG_FAILURE: [chars]: failed to sync log: [chars] 

Explanation    PSS cannot sync log due to filesystem or disk error

Recommended Action    No action is required.

Error Message     PSS-0-PSS_UNKNOWN_LOG: [chars]: unknown log type [hex] at offset [dec] 

Explanation    Unknown logging entry found

Recommended Action    No action is required.

Error Message     PSS-0-PSS_WRITE_DATA_FAILURE: [chars]: failed to write data to 
[chars] block [dec]: [chars] 

Explanation    PSS cannot write data due to filesystem or disk error

Recommended Action    No action is required.

Error Message     PSS-0-PSS_WRITE_LOG_FAILURE: [chars]: failed to write log: [chars] 

Explanation    PSS cannot write log due to filesystem or disk error

Recommended Action    No action is required.

PSS-1

Error Message     PSS-1-PSS_INVALID_MAGIC: [chars]: database [chars] has invalid magic 
number [hex] 

Explanation    PSS found a corrupted database with invalid magic number

Recommended Action    No action is required.

Error Message     PSS-1-PSS_META_READ_ERROR: [chars]: cannot read meta page from 
[chars]: [chars] 

Explanation    PSS cannot read meta page of a database

Recommended Action    No action is required.

Error Message     PSS-1-PSS_STAT_ERROR: [chars]: cannot stat [chars]: [chars] 

Explanation    PSS cannot do fstat on a database

Recommended Action    No action is required.

Error Message     PSS-1-PSS_VERSION_MISMATCH: [chars]: found version mismatch in 
[chars] 

Explanation    PSS found a database whose format it cannot interpret due to version mismatch

Recommended Action    The image upgrade was not done properly; write erase shold cure it as a last step

PSS-2

Error Message     PSS-2-PSS_INVALID_SIZE: [chars]: database [chars] ([chars]) has 
invalid size %ld (block size [dec]) 

Explanation    PSS found a database with invalid size - probably due to a crash

Recommended Action    No action is required.

Error Message     PSS-2-PSS_MISSING_FILE: [chars]: database [chars] missing [chars] 
file 

Explanation    PSS database is incomplete; probably due to a crash

Recommended Action    No action is required.

Error Message     PSS-2-PSS_RECOVERY_FAILED: [chars]: failed to recover [chars] 

Explanation    PSS recovery failed

Recommended Action    No action is required.

PSS-4

Error Message     PSS-4-PSS_CLEANUP: [chars]: cleaning up [chars] 

Explanation    PSS removed a leftover or corrupted file

Recommended Action    No action is required.

Error Message     PSS-4-PSS_RECOVERY_ENDED: [chars]: recovered [chars] successfully 

Explanation    PSS recovery finished

Recommended Action    No action is required.

Error Message     PSS-4-PSS_RECOVERY_STARTED: [chars]: recovering [chars]: [dec] valid 
transactional records 

Explanation    PSS started recovery of previous aborted transaction

Recommended Action    No action is required.

PSS-5

Error Message     PSS-5-PSS_CONVERT_FORMAT: [chars]: converting pss format: [chars] 

Explanation    PSS format is being converted

Recommended Action    No action is required.

Error Message     PSS-5-PSS_CONVERT_LAYOUT: [chars]: converting pss layout: [chars] 
(params [dec]/[dec]/[dec] -> [dec]/[dec]/[dec]) 

Explanation    PSS layout is being converted

Recommended Action    No action is required.

Error Message     PSS-5-PSS_SHRINK: [chars]: shrinking pss: [chars] 

Explanation    PSS is being shrunk to remove free space

Recommended Action    No action is required.

Error Message     PSS-5-SDB_CLOSED_AT_COMMIT: [chars]: sdb [chars] is closed: token 
[dec] is not committed 

Explanation    Publisher received SDB commit but sdb was already closed

Recommended Action    No action is required.

QOS Messages

This section contains the QOS messages.

QOS-2

Error Message    QOS-2-EXITING: Exit reason: [chars] 

Explanation    The QOS Manager process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     QOS-2-GENERAL_ERROR: [chars] 

Explanation    The QOS Manager has encountered an critical error. The description of error is [str.].

Recommended Action    No action is required.

Error Message     QOS-2-INITFAIL: QoS Manager Initialization failed: [chars] 

Explanation    QoS Manager initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     QOS-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The QOS Manager could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     QOS-2-PSS_ERROR: [chars]: PSS returned value=[dec] 

Explanation    The QOS Manager encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     QOS-2-STDOUT_ROTATE_FAILURE: Failed to rotate stdout file: [chars] 

Explanation    The QOS Manager has failed to rotate its current stdout file with filename [str.]. The file size could grow beyond its maximum limit.

Recommended Action    No action is required.

QOS-3

Error Message     QOS-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    QoS Manager is out of dynamic memory. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     QOS-3-DBERROR: [chars] 

Explanation    QoS Manager encountered a database error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     QOS-3-E_PORT_ACL_FAILURE: Failed to [chars] QOS ACL for interface 
[chars] (ACL return code=[hex]) 

Explanation    The QOS Manager has failed to program or erase QoS related ACL when an E-Port came up or went down for interface [str.]. The error code returned by ACL module is [int.].

Recommended Action    No action is required.

Error Message     QOS-3-FAILURE_RESPONSE: [chars] [hex] 

Explanation    QoS Manager failed to get response [chars][hex] specify the context where the failure occurred.

Recommended Action    No action is required.

Error Message     QOS-3-GENERROR: [chars] 

Explanation    QoS Manager encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     QOS-3-LICERR: [chars] 

Explanation    QoS Manager failed to get license.

Recommended Action    No action is required.

Error Message     QOS-3-MTSERROR: [chars] 

Explanation    QoS Manager encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     QOS-3-PSSERROR: [chars] 

Explanation    QoS Manager encountered a PSS error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     QOS-3-QOS_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The QOS Manager has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     QOS-3-TIMEOUT_ERROR: [chars] [hex] 

Explanation    QoS Manager encountered a timeout [chars][hex] specify the context where the failure occurred.

Recommended Action    No action is required.

Error Message     QOS-3-UNKNOWN_MSG: Received from Node=[dec] SAP=[dec] 

Explanation    The QOS Manager has received an unknown message from [dec]].[dec]. This information is for debugging only.

Recommended Action    No action is required.

QOS-4

Error Message     QOS-4-LICEXP: [chars] 

Explanation    QoS Manager license is going to expire. [chars] gives the expected time of expiry.

Recommended Action    No action is required.

Error Message     QOS-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the QOS Manager and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

QOS-6

Error Message     QOS-6-BECAME_ACTIVE: Became ACTIVE from standby mode. 

Explanation    The QOS Manager on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     QOS-6-BECAME_STDBY: Became STANDBY from active mode. 

Explanation    The QOS Manager became standby from active mode.

Recommended Action    No action is required.

Error Message     QOS-6-DISABLED_UP_MARKING: [chars] 

Explanation    The QoS Manager has disabled marking of time-critical control traffic as high-priority traffic. Priority of such traffic is now not altered by QoS Manager.

Recommended Action    No action is required.

Error Message     QOS-6-ENABLED_UP_MARKING: [chars] 

Explanation    The QoS Manager has enabled marking of time-critical control traffic as high-priority traffic.

Recommended Action    No action is required.

Error Message     QOS-6-EXCESSIVE_DELAY: [chars] 

Explanation    Excessive time taken for a processing event. The description of the event is [str.].

Recommended Action    No action is required.

Error Message     QOS-6-E_PORT_ACL_SUCCESS: Successfully [chars] QOS ACL for interface 
[chars] 

Explanation    The QOS Manager has successfully programmed or erased QoS related ACL when an E-Port came up or went down for interface [str.].

Recommended Action    No action is required.

Error Message     QOS-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The QOS Manager was unable to send heartbeat to the system manager.

Recommended Action    No action is required.

Error Message     QOS-6-GENERAL_EVENT: [chars] 

Explanation    The QOS Manager has generated an important event. The description of the event is [str.].

Recommended Action    No action is required.

Error Message     QOS-6-MGRCREATED: QoS Manager created 

Explanation    QoS Manager was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     QOS-6-MGREXIT: QoS Manager shutting down gracefully 

Explanation    QoS Manager is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     QOS-6-PSS_CREATED: [chars] PSS Created 

Explanation    One of the persistent information database of QOS Manager has been recreated.

Recommended Action    No action is required.

Error Message     QOS-6-PSS_DESTROYED: [chars] PSS Destroyed 

Explanation    One of the persistent information databases of QoS Manager has been intentionally destroyed and would be recreated.

Recommended Action    No action is required.

Error Message     QOS-6-SERVICE_UP: Initialized [chars] 

Explanation    The QOS Manager is up and ready to accept client requests The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     QOS-6-SWITCHOVER: Switching Over to other Supervisor. 

Explanation    The QOS Manager has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

Error Message     QOS-6-UNKNOWNMTS: QoS Manager received an unexpected message 

Explanation    QoS Manager received an unexpected message.

Recommended Action    No action is required.

RADIUS Messages

This section contains the RADIUS messages.

RADIUS-2

Error Message    RADIUS-2-RADIUS_NO_AUTHEN_INFO: ASCII authentication not supported 

Explanation    ASCII authentication not supported.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RADIUS-2-RADIUS_PROGRAM_EXIT: RADIUS daemon exiting: [chars] 

Explanation    RADIUS daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RADIUS-3

Error Message     RADIUS-3-RADIUS_ERROR_MESSAGE: [chars] 

Explanation    RADIUS Error Message

Recommended Action    No action is required.

RADIUS-5

Error Message     RADIUS-5-RADIUS_MONITOR_STATUS: [chars] [chars] 

Explanation    Notifying Radius server monitor status change

Recommended Action    No action is required.

Error Message     RADIUS-5-RADIUS_NOTIFICATION: [chars] 

Explanation    RADIUS Notification

Recommended Action    No action is required.

Error Message     RADIUS-5-RADIUS_SERVER_STATUS: [chars] server [chars] with auth-port 
[dec] and acct-port [dec] status has changed from [chars] to [chars]. Server was 
in previous-state for [chars], and total dead time of the server is [chars] 

Explanation    Notifying Radius server status change

Recommended Action    No action is required.

RADIUS-6

Error Message     RADIUS-6-RADIUS_ACCOUNTING_MESSAGE: [chars] 

Explanation    Accounting Message

Recommended Action    No action is required.

Error Message     RADIUS-6-RADIUS_MESSAGE: [chars] 

Explanation    RADIUS Message

Recommended Action    No action is required.

RDL Messages

This section contains the RDL messages.

RDL-2

Error Message    RDL-2-PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], 
expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RDL-3

Error Message     RDL-3-SYSLOG_ALLOC_FAIL: : [chars] 

Explanation    RDL memory allocation failed : [chars].

Recommended Action    No action is required.

Error Message     RDL-3-SYSLOG_CONTEXT_ERR: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec].

Recommended Action    No action is required.

Error Message     RDL-3-SYSLOG_ERR: : [chars] 

Explanation    RDL syslog errors : [chars].

Recommended Action    No action is required.

Error Message     RDL-3-SYSLOG_EXIT: : [chars] 

Explanation    RDL exiting on errors : [chars].

Recommended Action    No action is required.

Error Message     RDL-3-SYSLOG_INIT_FAIL: : [chars] [chars] 

Explanation    RDL Initialization Failed: [chars] [chars].

Recommended Action    No action is required.

Error Message     RDL-3-SYSLOG_MTS_ERR: : [chars] 

Explanation    RDL MTS errors : [chars].

Recommended Action    No action is required.

RDL-6

Error Message     RDL-6-INFORMATION: [chars] 

Explanation    An event happend that affects RDL. [chars] indicates the event

Recommended Action    No action is required.

Error Message     RDL-6-PSS_ERR: [chars] 

Explanation    An error occurred during an RDL PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RDL-6-SYSLOG_DEBUG_1: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec].

Recommended Action    No action is required.

Error Message     RDL-6-SYSLOG_DEBUG_2: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec].

Recommended Action    No action is required.

Error Message     RDL-6-SYSLOG_INFO: : [chars] 

Explanation    RDL Debug logs: [chars].

Recommended Action    No action is required.

Error Message     RDL-6-SYSLOG_RESP_RCVD: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec].

Recommended Action    No action is required.

RES_MGR Messages

This section contains the RES_MGR messages.

RES_MGR-1

Error Message    RES_MGR-1-RES_MGR_HA_ERR: HA sync message received for resource [dec] 
which does not exist 

Explanation    RES_MGR Received HA msg for resource which does not exist Please check standby status and restart standby to recover

Recommended Action    No action is required.

RES_MGR-2

Error Message     RES_MGR-2-RES_MGR_CRIT: RES_MGR Critical: [chars] 

Explanation    RES_MGR generic critical condition

Recommended Action    No action is required.

Error Message     RES_MGR-2-RES_MGR_HA_PSS_ERR: HA sync message received for resource 
[dec] with wrong pss type [dec] 

Explanation    RES_MGR Received HA msg for resource which does not exist Please check standby status and restart standby to recover

Recommended Action    No action is required.

RES_MGR-3

Error Message     RES_MGR-3-RES_MGR_RES_ALREADY_EXCEEDED: The VDC [dec] is currently 
already using more [chars] resources than the desired new maximum limit 

Explanation    A \limit-resource\ command was issued such that a VDC would be a forbidden state if we obeyed, having already allocated more resources than the new maximum limit

Recommended Action    No action is required.

Error Message     RES_MGR-3-RES_MGR_RES_MAX_LOWER_THAN_MIN: The maximum limit for 
[chars] resources is not allowed to be less than the minimum limit 

Explanation    A \limit-resource\ command was issued such that the desired maximum limit was lower than the desired minimum limit

Recommended Action    No action is required.

Error Message     RES_MGR-3-RES_MGR_RES_TOO_HIGH: Limits for [chars] resources are not 
allowed to be set as high 

Explanation    A \limit-resource\ command was issued such that a desired limit couldn't be satisfied because of static policies

Recommended Action    No action is required.

Error Message     RES_MGR-3-RES_MGR_RES_UNAVAIL: Missing [dec] [chars] resources 
currently available to satisfy the minimum limit requested for vdc [dec] 

Explanation    A \limit-resource\ command was issued such that the desired minimum limit couldn't be satisfied with the currently available resources

Recommended Action    No action is required.

RES_MGR-4

Error Message     RES_MGR-4-RES_MGR_MAX_ALLOWED_VDCS_HAS_DECREASED: The maximum number 
of allowed VDCs has decreased from [dec] to [dec] since binary config was saved. 

Explanation    When startup config was saved, more VDCs were allowed in the system.

Recommended Action    No action is required.

Error Message     RES_MGR-4-RES_MGR_RES_ALREADY_EXCEEDED_BUT_NOT_ENFORCED: The VDC 
[dec] is currently already using more [chars] resources than the desired new 
maximum limit. You may experience some route loss upon switchover, when the new 
limits will actually take effect.

Explanation    A \limit-resource\ command was issued such that a VDC may not have enough memory for holding the current amount of routing entries when the new limits will be enforced upon switchover

Recommended Action    No action is required.

Error Message     RES_MGR-4-RES_MGR_SC_PSS_PCW_NETADMIN: Performing partial config 
write for resource [chars] in vdc [dec] 

Explanation    A \copy running-config startup-config\ command was issued from a local admin resource limits for the specified resource in the specified vdc had to be saved as a side-effect of it

Recommended Action    No action is required.

Error Message     RES_MGR-4-RES_MGR_SC_PSS_PCW: Performing partial config write for 
resource [chars] 

Explanation    A \copy running-config startup-config\ command was issued from another VDC resource limits for the specified resource had to be saved as part of it

Recommended Action    No action is required.

RES_MGR-5

Error Message     RES_MGR-5-RES_MGR_DISABLED: RES_MGR Disabled 

Explanation    RES_MGR Service Disabled

Recommended Action    No action is required.

Error Message     RES_MGR-5-RES_MGR_ENABLED: RES_MGR Enabled 

Explanation    RES_MGR Service Enabled

Recommended Action    No action is required.

RES_MGR-6

Error Message     RES_MGR-6-RES_MGR_CONDITION_VERIFIED: error [hex] [[chars]] during 
sysmgrcb_vdc_handshake_done() for vdc [dec] 

Explanation    RES_MGR is spotting some issue when VDC got created

Recommended Action    No action is required.

RIB Messages

This section contains the RIB messages.

RIB-0

Error Message    RIB-0-EMERG: [chars] 

Explanation    Rib caused a system failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RIB-1

Error Message     RIB-1-ALERT: [chars] 

Explanation    Rib caused failures in other services

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RIB-2

Error Message     RIB-2-CRIT: [chars] 

Explanation    Rib encountered a catastrophic error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RIB-3

Error Message     RIB-3-ERR: [chars] 

Explanation    Rib encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RIB-3-FIB_EXIT: fib exited 

Explanation    Fib had exited and may not continue operation

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RIB-3-MISS_APPS: Missing response from service 

Explanation    Service not responding to rib

Recommended Action    Please perform 'debug rib error', then recreate the operation scenario, to find out more details.

Error Message     RIB-3-NO_MEM: Out of memory 

Explanation    Rib does not have enough memory to continue proper operation.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RIB-3-SEND_FIB: Cannot talk to fib 

Explanation    Rib to fib IPC failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RIB-3-SEND_SNMP: Cannot respond to snmp 

Explanation    Rib to snmp IPC failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     RIB-3-SEND_STANDBY: Cannot talk to standby rib 

Explanation    Lost a rib-fib transaction log due to IPC failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

RIB-4

Error Message     RIB-4-CPU_HOG: Inactive or busy 

Explanation    Either rib was not scheduled to run, or rib was busy, and rib did not service the message or timer queue for an extended period.

Recommended Action    Please perform 'debug rib error', then recreate the operation scenario, to find out more details.

Error Message     RIB-4-DUP_FIB: Duplicate response from fib 

Explanation    Rib ignored duplicate response from fib

Recommended Action    Please perform 'debug rib error', then recreate the operation scenario, to find out more details.

Error Message     RIB-4-LATE_FIB: Late response from fib 

Explanation    Rib ignored late response from fib

Recommended Action    Please perform 'debug rib error', then recreate the operation scenario, to find out more details.

Error Message     RIB-4-PC_LIMIT: PC number greater than 128 (ignored by RIB) 

Explanation    Rib ignored pc > 128 for multicast

Recommended Action    Please use PC number < 128

Error Message     RIB-4-WARN: [chars] 

Explanation    Rib ignored the unexpected condition

Recommended Action    Please perform 'debug rib all', then recreate the operation scenario, to find out more details.

RIB-5

Error Message     RIB-5-NOTE: [chars] 

Explanation    Rib does not support this operation

Recommended Action    Please perform 'debug rib all', then recreate the operation scenario, to find out more details.

RIB-6

Error Message     RIB-6-INFO: [chars] 

Explanation    Rib event occurred

Recommended Action    No action is required.

RLIR Messages

This section contains the RLIR messages.

RLIR-2

Error Message    RLIR-2-DRLIR_REJECT: DRLIR rejected: [chars]: fcid [chars], reason 
code [dec] 

Explanation    DRLIR rejected: [chars] fcid [chars] reason code [dec]

Recommended Action    No action is required.

Error Message     RLIR-2-FC2_FAILED: RLIR FC2 operation failed: [chars]: [chars] 

Explanation    RLIR FC2 operation failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     RLIR-2-INIT_FAILED: RLIR Init failed: [chars] 

Explanation    RLIR Init failed: [chars]

Recommended Action    No action is required.

Error Message     RLIR-2-LINK_INCIDENT: Interface [chars] [Port [hex]], Link Status: 
[chars], Link Status Reason: [chars]

Explanation    RLIR module detected an unintentional Link Incident

Recommended Action    No action is required.

Error Message     RLIR-2-MALLOC_FAILED: RLIR Malloc failed: [chars] 

Explanation    RLIR Malloc failed: [chars]

Recommended Action    No action is required.

Error Message     RLIR-2-MTS_FAILED: RLIR MTS operation failed: [chars]: [chars] 

Explanation    RLIR MTS operation failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     RLIR-2-PSS_FAILED: RLIR PSS operation failed: [chars]: [chars] 

Explanation    RLIR PSS operation failed: [chars] [chars]

Recommended Action    No action is required.

RLIR-6

Error Message     RLIR-6-SYSLOG_INFO: RLIR Syslog info: [chars] 

Explanation    RLIR Syslog info: [chars]

Recommended Action    No action is required.

Error Message     RLIR-6-SYSLOG_STATUS: RLIR Syslog status: [chars]: [chars] 

Explanation    RLIR Syslog status: [chars] [chars]

Recommended Action    No action is required.

RM Messages

This section contains the RM messages.

RM-6

Error Message    RM-6-RMGR_INFO: [chars] 

Explanation    RMGR daemon informational message

Recommended Action    No action is required.

Error Message     RM-6-STARTING: deamon started 

Explanation    The RMGR daemon successfully started

Recommended Action    No action is required.

RM-SLOT#-2

Error Message     RM-SLOT#-2-CPP_CATASTROPHIC_ERROR: ERROR: Component ([chars]) caused 
critical error. Service Module will be rebooted 

Explanation    Component caused critical error

Recommended Action    Restart the linecard

Error Message     RM-SLOT#-2-RM_CPP_RELOAD_TMOUT: ERROR: Component ([chars]) timed out 
for critical error response. Reloading Service Module 

Explanation    Component critical error timeout

Recommended Action    No action is required.

Error Message     RM-SLOT#-2-RM_CRITICAL_ALERT: [chars] 

Explanation    Critical Alert

Recommended Action    Restart the linecard

Error Message     RM-SLOT#-2-RM_PROCESS_FAILED: ERROR: [chars] failed 

Explanation    Process failed

Recommended Action    No action is required.

Error Message     RM-SLOT#-2-RM_PROCESS_TMOUT: ERROR: [chars] did not complete. 
Reloading Service Module 

Explanation    Component critical error timeout

Recommended Action    No action is required.

Error Message     RM-SLOT#-2-RM_VICPP_RECREATE_ERROR: All the fast path resources are 
down VICPP connectivity lost 

Explanation    Component caused critical error

Recommended Action    Restart the linecard

RM-SLOT#-4

Error Message     RM-SLOT#-4-RM_WARNING: [chars] 

Explanation    Warning

Recommended Action    No action is required.

RSCN Messages

This section contains the RSCN messages.

RSCN-2

Error Message    RSCN-2-FC2_FAILED: RSCN FC2 operation failed: [chars]: [chars] 

Explanation    RSCN FC2 operation failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     RSCN-2-INIT_FAILED: RSCN Init failed: [chars] 

Explanation    RSCN Init failed: [chars]

Recommended Action    No action is required.

Error Message     RSCN-2-MALLOC_FAILED: RSCN Malloc failed: [chars] 

Explanation    RSCN Malloc failed: [chars]

Recommended Action    No action is required.

Error Message     RSCN-2-MTS_FAILED: RSCN MTS operation failed: [chars]: [chars] 

Explanation    RSCN MTS operation failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     RSCN-2-PSS_FAILED: RSCN PSS operation failed: [chars]: [chars] 

Explanation    RSCN PSS operation failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     RSCN-2-SCR_REJECT: SCR rejected: [chars]: fcid [chars], Reason 
code-[chars], Reason code expl-[chars]

Explanation    SCR rejected: [chars] fcid [chars] Reason code [chars] Reason code expl [chars]

Recommended Action    No action is required.

RSCN-4

Error Message     RSCN-4-RSCN_REJECT: RSCN rejected: [chars]: fcid [chars], Reason 
code-[chars], Reason code expl-[chars]

Explanation    RSCN rejected: [chars] fcid [chars] Reason code [chars] Reason code expl [chars]

Recommended Action    No action is required.

Error Message     RSCN-4-SWRSCN_REJECT: SW-RSCN rejected: [chars]: fcid [chars], Reason 
code-[chars], Reason code expl-[chars]

Explanation    SW-RSCN rejected: [chars] fcid [chars] Reason code [chars] Reason code expl [chars]

Recommended Action    No action is required.

RSCN-6

Error Message     RSCN-6-SYSLOG_INFO: RSCN Syslog info: [chars] 

Explanation    RSCN Syslog info: [chars]

Recommended Action    No action is required.

Error Message     RSCN-6-SYSLOG_STATUS: RSCN Syslog status: [chars]: [chars] 

Explanation    RSCN Syslog status: [chars] [chars]

Recommended Action    No action is required.

SAL Messages

This section contains the SAL messages.

SAL-5

Error Message    SAL-5-SAL_DISABLED: SAL Disabled 

Explanation    SAL Service Disabled

Recommended Action    No action is required.

Error Message     SAL-5-SAL_ENABLED: SAL Enabled 

Explanation    SAL Service nabled

Recommended Action    No action is required.

SAN_EXT_TUNER Messages

This section contains the SAN_EXT_TUNER messages.

SAN_EXT_TUNER-3

Error Message    SAN_EXT_TUNER-3-SAN_EXT_TUNER_LICENSE_EXPIRED: SAN Extension Licence 
expired - Disabling SAN Extension Tuner 

Explanation    SAN Extension Licence expired/not present - Disabling SAN Extension Tuner

Recommended Action    No action is required.

SCHEDULER Messages

This section contains the SCHEDULER messages.

SCHEDULER-2

Error Message    SCHEDULER-2-SCH_SYSLOG_MALLOC_ERR: Out of memory: [chars] 

Explanation    Process memory exhausted. Possible memory leak.

Recommended Action    Contact TAC

Error Message     SCHEDULER-2-SCH_SYSLOG_MTS_ERR: MTS error: [chars] 

Explanation    MTS operation failure

Recommended Action    Contact TAC

Error Message     SCHEDULER-2-SCH_SYSLOG_PSS_SNAPSHOT_ERR: Source URI:[chars] 
Destination URI:[chars] errcode:[dec] 

Explanation    Error while performing snapshot I/O to PSS

Recommended Action    Contact TAC

Error Message     SCHEDULER-2-SCH_SYSLOG_SDWRAP_ERR: Debug infrastructure 
initialization failed: [chars] 

Explanation    Debug infrastructure failed to initialize

Recommended Action    Contact TAC

SCHEDULER-3

Error Message     SCHEDULER-3-SCH_ERR: [chars] 

Explanation    Scheduler error

Recommended Action    No action is required.

Error Message     SCHEDULER-3-SCH_SYSLOG_FILE_ERR: [chars] Error:[chars] 

Explanation    File handling error

Recommended Action    No action is required.

Error Message     SCHEDULER-3-SCH_SYSLOG_PSS_ERR: Purpose:[chars] URI:[chars] 
Error:[dec] 

Explanation    Error while performing I/O to PSS

Recommended Action    Contact TAC

Error Message     SCHEDULER-3-SCH_SYSLOG_USER_ERR: Description: Failed to execute job 
for user id [chars] Error:[dec] 

Explanation    Error while attempting to execute job for user. Possibly, the user is removed from the system.

Recommended Action    Ensure the user exists. Make sure he is not a remotely authenticated user.

SCHEDULER-4

Error Message     SCHEDULER-4-SCH_WARN: [chars] 

Explanation    Scheduler warning

Recommended Action    No action is required.

SCHEDULER-6

Error Message     SCHEDULER-6-SCH_MSG: [chars] 

Explanation    Scheduler Message

Recommended Action    No action is required.

SCSI-TARGET Messages

This section contains the SCSI-TARGET messages.

SCSI-TARGET-2

Error Message    SCSI-TARGET-2-PROC_ADD_NPORT_FAIL: Failed to set local nport with 
SCSI-target driver error: [hex] 

Explanation    SCSI-target process add nport with it's peer kernel driver [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show scsi-target internal driver'.

Error Message     SCSI-TARGET-2-PROC_OPEN_VHBA_DEVICE_FAIL: Failed to communicate with 
SCSI-target driver error: [hex] 

Explanation    SCSI-target process failed to communicate with it's peer kernel driver [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show scsi-target internal driver'.

Error Message     SCSI-TARGET-2-PROC_SET_SCSI_INDEX_FAIL: Failed to set SCSI index 
SCSI-target driver error: [hex] 

Explanation    SCSI-target process failed to set SCSI index with it's peer kernel driver [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show scsi-target internal driver'.

Error Message     SCSI-TARGET-2-PROC_WWNM_GET_WWN_FAIL: Failed to get local controller 
pwwn from WWN Manager error: [hex] response: [hex] 

Explanation    SCSI-target process used wwnm_bwt_get_local_controller_wwn() api for the port wwn and it failed due to error [hex], response code [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using commands 'show process cpu' and 'show system internal sysmgr service all'. See WWN Manager system error codes for reason.

Error Message     SCSI-TARGET-2-PSS_INIT_FAIL: pss initialization failed due to error: 
[hex] 

Explanation    SCSI-target process pss initialization failure due to error [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

SCSI-TARGET-3

Error Message     SCSI-TARGET-3-PROC_VSAN_GET_RATOV_FAIL: Failed to get vsan attribute 
RATOV from VSAN Manager, error: [hex] 

Explanation    SCSI-target process used the vsan_get_global_value() api for RATOV and it failed due to error [hex].

Recommended Action    This is a non-fatal error. The default value for RATOV is used. Collect more information using commands 'show process cpu' and 'show system internal sysmgr service all'. See Vsan Manager system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_CREATE_FAIL: pss create runtime database failed due 
to error: [hex] 

Explanation    SCSI-target process pss create runtime database failure due to error [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] 
failed due to error: [hex] 

Explanation    SCSI-target process pss delete runtime entry key [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to 
error: [hex] 

Explanation    SCSI-target process pss set runtime max key failure due to error [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed 
due to error: [hex] 

Explanation    SCSI-target process pss set runtime max value failure due to error [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_OPEN_FAIL: pss open runtime database failed due to 
error: [hex] 

Explanation    SCSI-target process pss open runtime database failure due to error [hex]. No SCSI discovery can be performed.

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_RELOAD_FAIL: pss reload runtime database failed due 
to error: [hex] 

Explanation    SCSI-target process pss reload runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_SNAPSHOT_DEBUG_FAIL: pss snapshot runtime debug to 
uri:[chars] failed due to error: [hex] 

Explanation    SCSI-target process pss snapshot of runtime debug to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_SNAPSHOT_FAIL: pss snapshot runtime to uri:[chars] 
failed due to error: [hex] 

Explanation    SCSI-target process pss snapshot of runtime to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     SCSI-TARGET-3-PSS_STORE_FAIL: pss store runtime entry key:[hex] 
val:[hex] failed due to error: [hex] 

Explanation    SCSI-target process pss store runtime entry key [hex] value [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

SCSI-TARGET-7

Error Message     SCSI-TARGET-7-SCSI_TARGET_DISCOVERED: SCSI-target discovered 
VSAN:[dec] FCID:[hex] prlisparm:[hex] 

Explanation    SCSI-target process discovered VSAN [dec] FCID [hex] prli service parameter [hex].

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

SDV Messages

This section contains the SDV messages.

SDV-2

Error Message    SDV-2-RANDNUM_FAIL: Random number generation failed 

Explanation    Random number generation failed. Process has to exit due to FIPS compliance

Recommended Action    No action is required.

SDV-3

Error Message     SDV-3-ACL_CACHE_ERROR: ACL CACHE ERR, Trying to prog with no interface 
list 

Explanation    A Null interface list was generated for a ACL entry

Recommended Action    No action is required.

Error Message     SDV-3-ACL_ERROR: ACL API, [chars], failed with error [hex] 

Explanation    SDV invoked ACL API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     SDV-3-ALLOC_FAILED: Failed for type [dec] size [dec] 

Explanation    SDM process could not allocate heap memory. [dec] is the memory type and [dec] is the size of memory

Recommended Action    No action is required.

Error Message     SDV-3-ASSERTION_FAILED: [chars]:[dec] 

Explanation    SDM process has hit an assert condition at file [chars] line number [dec]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SDV-3-AUTO_FAILOVER_ERROR: [chars] 

Explanation    SDV Virtual-device failed to auto-failover due to [chars]

Recommended Action    No action is required.

Error Message     SDV-3-BCAST_NOT_SUPPORTED: Broadcast attribute will be ignored for 
SDV devices 

Explanation    Broadcast attribute will be ignored for SDV devices

Recommended Action    No action is required.

Error Message     SDV-3-ENQUEUE_EVENT_FAIL: Unable to enqueue event into state machine 

Explanation    Unable to enqueue event into state machine

Recommended Action    No action is required.

Error Message     SDV-3-FCID_REWRITE_REQUEST_TO_ACL_FAILED: fcid rewrite [chars] 
request vsan [dec] vdev_id [dec] failed:[chars]. 

Explanation    This happens when either after SDV retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     SDV-3-INIT_FAIL: [chars] 

Explanation    SDM process init has failed due to [chars]

Recommended Action    No action is required.

Error Message     SDV-3-INTERNAL_ERR: [chars] 

Explanation    SDM process encountered an internal error due to [chars]

Recommended Action    No action is required.

Error Message     SDV-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. The reason for the failure : [chars]

Recommended Action    No action is required.

Error Message     SDV-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    Error while activating the merged SDV database due to [chars]

Recommended Action    No action is required.

Error Message     SDV-3-MERGE_CAP_FAILED: [chars] 

Explanation    SDV fabric merge failed because of incomaptible capabilities [chars]

Recommended Action    Compare SDV configuration in both fabrics and resolve the conflicts if any and commit the changes.

Error Message     SDV-3-MERGE_FAILED: [chars] 

Explanation    SDV fabric merge failed due to [chars]

Recommended Action    Check the error using show sdv merge staus vsan <vsan-id> command. Compare SDV configuration in both fabrics and resolve the conflicts if any and commit the changes.

Error Message     SDV-3-MTS_ERR: [chars] 

Explanation    SDM process encountered an MTS error due to [chars]

Recommended Action    No action is required.

SDV-4

Error Message     SDV-4-FCID_REWRITE_REQUEST_TO_ACL_FAILED_AND_RETRYING: 
failed:[chars]. Retrying the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

SDV-6

Error Message     SDV-6-INTERNAL_ERR_INFO: [chars] 

Explanation    SDM process encountered ignorable error due to [chars]

Recommended Action    No action is required.

SDV-7

Error Message     SDV-7-SRVCREATED: SDM Process started 

Explanation    SDM process has started

Recommended Action    No action is required.

SECURITYD Messages

This section contains the SECURITYD messages.

SECURITYD-2

Error Message    SECURITYD-2-FIPS_BYPASS_SELF_TEST_STATUS: FIPS Bypass self-test 
status : [chars] 

Explanation    Status of FIPS self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_CRNG_SELF_TEST_STATUS: FIPS CRNG self-test status : 
[chars] 

Explanation    Status of FIPS self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_CRYPTO_SELF_TEST_STATUS: FIPS [chars] Crypto 
self-test status : [chars] 

Explanation    Status of FIPS [chars] self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_IMAGE_INTEGRITY_SELF_TEST_STATUS: FIPS Image 
Integrity self-test status : [chars] 

Explanation    Status of FIPS [chars] self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_POWERUP_SELF_TESTS_STATUS: FIPS power-up self-test 
status: [chars] 

Explanation    Status FIPS self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_POWERUP_SELF_TEST_STATUS: FIPS [chars] power-up 
self-test status : [chars] 

Explanation    Status of FIPS [chars] power-up self-test [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-FIPS_SELF_TEST_FAILED: FIPS self-test failure : [chars] 
: [chars] 

Explanation    FIPS self-test failed [chars] for service [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-2-HTTP_ERR_DISABLED: HTTP service '[chars]' re-started more 
than 4 times in last 60 sec and hence err-disabled. Use 'feature http-server' to 
re-enable the feature 

Explanation    HTTP service is in err-disabled state as the process failed to re-start more than 4 times in last 60 sec.

Recommended Action    Use 'feature http-server' command to re-enable the feature

Error Message     SECURITYD-2-PROGRAM_EXIT: security/accounting daemon exiting: [chars] 

Explanation    Security/accounting daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

SECURITYD-3

Error Message     SECURITYD-3-NVRAMFAILURE: nvram failure 

Explanation    Nvram can not be read/written to. Hence accounting log can not be stored there

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

SECURITYD-5

Error Message     SECURITYD-5-HTTP_DISABLED: HTTP service '[chars]' is disabled 

Explanation    HTTP service is disabled

Recommended Action    No action is required.

Error Message     SECURITYD-5-HTTP_ENABLED: HTTP service '[chars]' is enabled 

Explanation    HTTP service is enabled

Recommended Action    No action is required.

SECURITYD-6

Error Message     SECURITYD-6-ACCOUNTING_MESSAGE: [chars] 

Explanation    Accounting Message

Recommended Action    No action is required.

Error Message     SECURITYD-6-CHANGE_PASSWD: changing passwd for [chars] 

Explanation    Changing passwd for [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-6-DELETE_STALE_USER_ACCOUNT: deleting expired user 
account:[chars] 

Explanation    Deleting expired user account of [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-6-FIPS_MODE_SET_FAILED: Error when setting FIPS mode : 
[chars] 

Explanation    FIPS mode failed [chars]

Recommended Action    No action is required.

Error Message     SECURITYD-6-FIPS_MODE_SET: FIPS mode is [chars] for service [chars] 

Explanation    FIPS mode is changed [chars] [chars]

Recommended Action    No action is required.

SENSOR_USD Messages

This section contains the SENSOR_USD messages.

SENSOR_USD-2

Error Message    SENSOR_USD-2-SNSM_SYSLOG_INIT_FAILED: Sensor Mgr Initialization 
failed. Component [chars] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-2-SNSM_SYSLOG_SHUTDOWN: Sensor Mgr process shutting down: 
[chars] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-2-SNSM_SYSYLOG_ALLOC_MEMORY: Sensor Mgr Memory allocation 
failed 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

SENSOR_USD-3

Error Message     SENSOR_USD-3-MSG_SNSM_SYS_MEM_ALOC_FAILURE: Sensor Mgr Error in 
allocing mem: [dec], Error code = [dec] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-3-SNSM_SYSLOG_BAD_MTS_MSG: Sensor Mgr Received bad MTS 
message: [dec] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-3-SNSM_SYSLOG_MTS_PROCESS_ERROR: Sensor Mgr Error in 
processing MTS message: [dec], Error code = [hex] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-3-SNSM_SYS_DEQUE_PENDING_QUE_FAILURE: Sensor Mgr Error in 
Dequing pend Que: %p, Error code = [hex] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-3-SNSM_SYS_ENQUE_PENDING_QUE_FAILED: Sensor Mgr Error in 
queuing to pending queue: %p, Error code = [hex] 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

Error Message     SENSOR_USD-3-SNSM_SYS_MTS_RECV_FAILURE: Sensor Mgr Error in receving 
MTS mesg 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

SENSOR_USD-5

Error Message     SENSOR_USD-5-SNSM_SYSLOG_STARTING: Sensor Mgr process started 

Explanation    Sensor Manager syslog message

Recommended Action    No action is required.

SENSOR_MGR Messages

This section contains the SENSOR_MGR messages.

SENSOR_MGR-2

Error Message    SESSION-MGR-2-DB_UNLOCK_FAILED: Failed to unlock the database for 
session:[chars] 

Explanation    Session-Manager failed to unlock the database for session: [chars]

Recommended Action    No action is required.

SENSOR_MGR-3

Error Message     SESSION-MGR-3-ALLOC_FAILED: Failed in File:[chars] Line:[dec] for 
type [dec] size [dec] 

Explanation    Session-mgr process could not allocate heap memory in File:[chars], at line:[dec], for memory-type:[dec] of Size:[dec]

Recommended Action    No action is required.

SENSOR_MGR-4

Error Message     SESSION-MGR-4-ISSU_FAILED: [chars] :[hex] 

Explanation    Session manager failed ISSU because of:[string] and error: [hex]

Recommended Action    No action is required.

SFC Messages

This section contains the SFC messages.

SFC-3

Error Message    SFC-3-ERROR: [chars] 

Explanation    SCSI Flow Client encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

SFM Messages

This section contains the SFM messages.

SFM-2

Error Message    SFM-2-NO_LICENSE_WARNING: SCSI Flow Manager is shutting down as no 
license is available. 

Explanation    License required for continued SCSI Flow Manager operation is not available.

Recommended Action    No action is required.

SFM-6

Error Message     SFM-6-LICENSE_VALID: A valid license for SCSI FLow Manager has been 
obtained 

Explanation    A valid license for SCSI Flow Manager has been obtained

Recommended Action    No action is required.

SKSD Messages

This section contains the SKSD messages.

SKSD-5

Error Message    SKSD-5-SKSD_EXIT: Keystore Application Exiting: [chars] 

Explanation    Keystore Program exiting

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_FUNC: Keystore Operation: [chars] 

Explanation    Keystore Event upon a receiving a request

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_HW_INIT: Hardware Keystore Init done 

Explanation    Hardware Keystore Init completed

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_HW_RESET: Hardware Reset :[chars] 

Explanation    Hardware Reset

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_HW: Smartcard :[chars] 

Explanation    Smartcard Presence

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_INIT: Keystore Application Init: [chars] 

Explanation    Keystore Program Init

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_KEY_ADD: Key added 

Explanation    Key added to keystore

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_KEY_DELETE: Key deleted 

Explanation    Key deleted from keystore

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_MKEY_INSTALL: Installing a Master Key on the smartcard(s) 

Explanation    Installing a new Master Key on the smartcard(s)

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_SUP_STATE: Supervisor card new state: [dec] 

Explanation    Supervisor state change

Recommended Action    No action is required.

Error Message     SKSD-5-SKSD_SW_INIT: Software Keystore Init done 

Explanation    Software Keystore Init completed

Recommended Action    No action is required.

SKT_USD Messages

This section contains the SKT_USD messages.

SKT_USD-3

Error Message    SKT_USD-6-SKT_DEBUG_MSG: [chars] 

Explanation    Debug log message

Recommended Action    No action is required.

SME_CPP Messages

This section contains the SME_CPP messages.

SME_CPP-2

Error Message    SME_CPP-2-IT_NEXUS_MAX_INTERFACE_LIMIT_REACHED: [chars] cannot be 
bound as the interfaces reached the maximum IT Nexus limit

Explanation    IT Load Balancing failed

Recommended Action    No action is required.

Error Message     SME_CPP-2-LOG_ERR_SME_CTRL_LUN_PATH_MISCONFIG: Control LUN [chars] 
behind Host PWWN [chars] Tgt PWWN [chars] LUN Id [chars] has some lun paths that 
are not configured. 

Explanation    A single lun with multiple paths has some non configured paths. Please configure all lun paths.

Recommended Action    No action is required.

Error Message     SME_CPP-2-LOG_ERR_SME_DIFF_LUN_MISCONFIG: Lun [chars] and [chars] 
behind Host PWWN [chars] Tgt PWWN [chars] LUN Id [chars] configured as one device. 

Explanation    Two different luns configured as one device. Please fix configuration.

Recommended Action    No action is required.

Error Message     SME_CPP-2-LOG_ERR_SME_LICENSE_EXPIRED: SME License expired - 
Disabling [chars] 

Explanation    SAN Media Encryption License expired/not present - Disabling SME

Recommended Action    No action is required.

Error Message     SME_CPP-2-LOG_ERR_SME_TAPE_LUN_PATH_MISCONFIG: Tape Drive [chars] 
behind Host PWWN [chars] Tgt PWWN [chars] LUN Id [chars] has some lun paths that 
are not configured. 

Explanation    A single lun with multiple paths has some non configured paths. Please configure all lun paths.

Recommended Action    No action is required.

Error Message     SME_CPP-2-LOG_WARN_SME_LICENSE_GRACE: No SME License. Feature will be 
shut down after a grace period of approximately [dec] days 

Explanation    SAN Media Encryption feature on grace period. Please acquire actual license.

Recommended Action    No action is required.

Error Message     SME_CPP-2-SME_INIT_FAILED: Initialization failed for SME: [chars], 
Reason: [hex] 

Explanation    Initialization failed for SME

Recommended Action    No action is required.

SME_CPP-3

Error Message     SME_CPP-3-LOG_ERR_SME_DBSYBC_REJECT: SME Database Synchronization 
[chars] for a New Cluster (Id 0x%llx) Rejected; Reason - [chars].

Explanation    A switch can be part of only one SME cluster

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_ERR_SME_INTF_MISMATCH_CLUSTER_PARAMS: SME interface 
[chars] part of cluster [chars] with ID [chars] and security mode [dec], but the 
DPP has state from a previous instance of a cluster [chars] with ID [chars] and 
security mode [dec]. 

Explanation    DPP has persistent state about a previous cluster membership incarnation, but the interface is part of a different cluster.

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_ERR_SME_INTF_MISMATCH_CRYPTO_NODE_CERTIFICATE2: but 
the DPP has a different certificate (len [dec] fingerprint [chars]). 

Explanation    DPP has persistent state about a previous cluster membership with a different crypto node identity.

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_ERR_SME_INTF_MISMATCH_CRYPTO_NODE_CERTIFICATE: SME 
interface [chars] part of cluster [chars] with ID [chars] as a crypto node [chars] 
with certificate (len [dec] fingerprint [chars]), ..

Explanation    DPP has persistent state about a previous cluster membership with a different crypto node identity.

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_ERR_SME_INTF_MISMATCH_CRYPTO_NODE_PARAMS: SME 
interface [chars] part of cluster [chars] with ID [chars] as a crypto node [chars], 
but the DPP is identified as [chars]. 

Explanation    DPP has persistent state about a previous cluster membershipon a different switch or module.

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KEY_CREATE_FAILED: Key creation ([chars]) failed 
with error ([chars]), SME cluster (name [chars], id %llx)

Explanation    SME key creation failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KMC_DELETE_ALL_KEYS_FAILED: Delete all keys in 
cluster failed to KMC server failed with error ([chars]), SME cluster (name 
[chars], id %llx)

Explanation    SME KMC delete keys failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KMC_DELETE_KEYS_FAILED: Delete keys for [chars] 
failed to KMC server failed with error ([chars]), SME cluster (name [chars], id 
%llx)

Explanation    SME KMC delete keys failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KMC_KEEPALIVE_FAILED: Keepalive to KMC server 
failed with error ([chars]), SME cluster (name [chars], id %llx)

Explanation    SME KMC keepalive failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KMC_KEY_LOOKUP_FAILED: Key ([chars]) lookup from 
KMC server failed with error ([chars]), SME cluster (name [chars], id %llx)

Explanation    SME KMC key lookup failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_KMC_KEY_UPDATE_FAILED: Key updates ([chars]) to KMC 
server failed with error ([chars]), SME cluster (name [chars], id %llx)

Explanation    SME KMC key updates failed

Recommended Action    No action is required.

Error Message     SME_CPP-3-LOG_SME_REPLACE_SMARTCARD_ABORT: Replace smartcard process 
(type [chars]) aborted [chars] with reason ([chars]) in SME cluster (name [chars], 
id %llx)

Explanation    SME KMC connection up

Recommended Action    No action is required.

SME_CPP-5

Error Message     SME_CPP-5-IT_NEXUS_OPTIMUM_INTERFACE_LIMIT_REACHED: Interface 
[chars] exceeded the optimum IT Nexus limit 

Explanation    Iterface Flow Limit

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_ERR_SME_INTF_MISMATCH_NOT_PART_OF_ANY_CLUSTER: SME 
interface [chars] not part of any cluster, but the DPP has state from a previous 
instance of a cluster [chars] with ID [chars]. 

Explanation    DPP has persistent state about a previous cluster membership incarnation, but the interface is not part of any cluster.

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_ERR_SME_INTF_MISMATCH_NOT_PROVISIONED: SME is not 
provisioned on slot [dec], but the DPP has state from a previous instance as a 
crypto node [chars] of a cluster [chars] with ID [chars].

Explanation    DPP has persistent state about a previous cluster membership incarnation, but the switch has not provisioned the interface for SME.

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_CLUSTER_INTF_ADDED: SME interface now part of 
cluster [chars] with ID [chars] as a crypto node [chars] and certificate (len [dec] 
fingerprint [chars]).

Explanation    Interface added to cluster successfully

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_CLUSTER_INTF_REMOVED: SME interface now removed 
from cluster [chars] with ID [chars] as a crypto node [chars] and certificate (len 
[dec] fingerprint [chars]).

Explanation    Interface removed from cluster successfully

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_INTERFACE_DOWN: SME Interface ([chars]) DOWN 

Explanation    SAN Interface was brought down

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_INTERFACE_UP: SME Interface ([chars]) is UP 

Explanation    SAN Interface was brought up

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_IT_NEXUS_FAILURE: [chars]. [chars] bind failure. 
Reason: [chars]: [hex] 

Explanation    SME IT Nexus bind failed

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KEY_CREATE_SUCCESS: Key created ([chars]) 
successfully in SME cluster (name [chars], id %llx)

Explanation    SME key creation succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_CONNECTION_DOWN: Connection to KMC server 
[chars] is down with reason ([chars]) from local switch in SME cluster (name 
[chars], id %llx)

Explanation    SME KMC connection down

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_CONNECTION_INIT_FAIL: Connection 
initialization to KMC server [chars] from local switch in SME cluster (name 
[chars], id %llx) failed with error ([chars])

Explanation    SME KMC connection initialization failed

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_CONNECTION_INIT_PASS: Connection 
initialization to KMC server [chars] from local switch in SME cluster (name 
[chars], id %llx) succeeded

Explanation    SME KMC connection initialization succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_CONNECTION_UP: Connection to KMC server [chars] 
is up from local switch in SME cluster (name [chars], id %llx)

Explanation    SME KMC connection up

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_DELETE_ALL_KEYS_SUCCESS: Delete all keys in 
cluster to KMC server succeeded, SME cluster (name [chars], id %llx)

Explanation    SME KMC delete keys succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_DELETE_KEYS_SUCCESS: Delete keys for [chars] to 
KMC server succeeded, SME cluster (name [chars], id %llx)

Explanation    SME KMC delete keys succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_KEY_LOOKUP_SUCCESS: Key ([chars]) lookup from 
KMC server succeeded, SME cluster (name [chars], id %llx)

Explanation    SME KMC key lookup succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_KMC_KEY_UPDATE_SUCCESS: Key updates ([chars]) to 
KMC server succeeded, SME cluster (name [chars], id %llx)

Explanation    SME KMC key updates succeeded

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_MASTER_KEY_REKEYED: Master Key rekeyed successfully 
in SME cluster (name [chars], id %llx)

Explanation    SME Master Key rekeyed

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_REPLACE_SMARTCARD_COMMIT: Replace smartcard 
process (type [chars]) committed [chars] in SME cluster (name [chars], id %llx)

Explanation    SME KMC connection up

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_REPLACE_SMARTCARD_START: Replace smartcard process 
(type [chars]) initiated [chars] in SME cluster (name [chars], id %llx)

Explanation    SME KMC connection up

Recommended Action    No action is required.

Error Message     SME_CPP-5-LOG_SME_TAPE_VOLUME_GROUP_REKEYED: Tape volume group 
([chars]) rekeyed successfully in SME cluster (name [chars], id %llx)

Explanation    SME Master Key rekeyed

Recommended Action    No action is required.

Error Message     SME_CPP-5-SME_DISABLED: SME Disabled 

Explanation    SME Service Disabled

Recommended Action    No action is required.

Error Message     SME_CPP-5-SME_ENABLED: SME Enabled 

Explanation    SME Service nabled

Recommended Action    No action is required.

SME_CPP-SLOT#-2

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_DEVICE_MISCONFIG: Different configured 
Devices under same physical LUN - Old Cluster Name:[chars] New Cluster 
Name:[chars] Old Group Name:[chars] New Group Name:[chars] Old Device Name:[chars] 
New Device Name:[chars] 

Explanation    Different configured devices under same physical LUN

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_ITL_MISCONFIG: Different physical LUNs 
under same Tape Device - Device Name:[chars] Host PWWN:[chars] Tgt PWWN:[chars] 
LUN Id:[chars] Serial Num:[chars] Serial Num:[chars] 

Explanation    Different physical LUNs under same Tape Device

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_LUN_MISCONFIG: Different physical LUNs 
under same ITL - Old Serial Num:[chars] New Serial Num:[chars] 

Explanation    Different physical LUNs under same ITL

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_TAPE_BYPASS_ENC: Bypassing encryption 
for partly written tape - Cluster:[chars] Tape Device:[chars] Serial Num:[chars] 

Explanation    This tape is currently not being encrypted

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_TAPE_CTH_FAIL: Bypassing encryption for 
current tape on failed CTH verification - Cluster:[chars] Tape Device:[chars] 
Serial Num:[chars] 

Explanation    This tape is currently not being encrypted because CTH verification has failed in DPP

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-2-LOG_ERR_SME_TAPE_KEY_ERR: Getting tape keys from SUP 
failed - Cluster:[chars] Tape Device:[chars] Serial Num:[chars] 

Explanation    There was a failure retrieving keys from SUP for this tape

Recommended Action    No action is required.

SME_CPP-SLOT#-3

Error Message     SME_CPP-SLOT#-3-LOG_ERR_SME_DISC_TIMEOUT: Module:[dec] 
Host-Target:[chars] 

Explanation    Discovery on this IT Nexus is taking too long, please check status

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-3-LOG_ERR_SME_ITL_CPP_ERR: Module:[dec] Host-Target 
[chars] LunID:[chars] 

Explanation    ITL failure seen on CPP, please check status

Recommended Action    No action is required.

Error Message     SME_CPP-SLOT#-3-LOG_ERR_SME_NON_TAPE_MISCONFIG: A non-tape device 
misconfigured under tape config - Device Name:[chars] Host PWWN:[chars] Tgt 
PWWN:[chars] LUN Id:%Ld 

Explanation    A disk misconfigured under tape config

Recommended Action    No action is required.

SME_CPP-SLOT#-4

Error Message     SME_CPP-SLOT#-4-LOG_WARN_SME_MAX_BLOCK_LEN: Maximum block length 
[dec] of tape drive is 256K or less - [chars] LunID:[chars] VendorID:[chars] 
ProdID:[chars] Serial Num:[chars] Cluster:[chars] Tape Device:[chars] 

Explanation    This tape drive may not operate correctly with SME

Recommended Action    No action is required.

SNMPD Messages

This section contains the SNMPD messages.

SNMPD-1

Error Message    SNMPD-1-ALERT: SNMP log alert : [chars] 

Explanation    SNMP log alert message.

Recommended Action    No action is required.

SNMPD-2

Error Message     SNMPD-2-CRITICAL: SNMP log critical : [chars] 

Explanation    SNMP log critical message.

Recommended Action    No action is required.

SNMPD-3

Error Message     SNMPD-3-ERROR: SNMP log error : [chars] 

Explanation    SNMP log error message.

Recommended Action    No action is required.

SNMPD-4

Error Message     SNMPD-4-WARNING: SNMP log warning : [chars] 

Explanation    SNMP log warning message.

Recommended Action    No action is required.

SNMPD-5

Error Message     SNMPD-5-NOTIFICATION: SNMP log notification : [chars] 

Explanation    SNMP log notification message.

Recommended Action    No action is required.

SNMPD-6

Error Message     SNMPD-6-INFO: SNMP log informational : [chars] 

Explanation    SNMP log info message.

Recommended Action    No action is required.

SNMPD-7

Error Message     SNMPD-7-DEBUG: SNMP log debugging : [chars] 

Explanation    SNMP log debug message.

Recommended Action    No action is required.

SPAN Messages

This section contains the SPAN messages.

SPAN-2

Error Message    SPAN-2-MEM_FULL: Memory allocation failed 

Explanation    Memory allocation failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

SPAN-3

Error Message     SPAN-3-IPC_FAIL: IPC Error 

Explanation    Internal IPC error

Recommended Action    No action is required.

Error Message     SPAN-3-SYSINFO_TIMEOUT: Span timed out waiting for response from port 
manager for sys info 

Explanation    Span request for critical system information from port manager timed out. So, span on the new active is exiting and system manager will restart Span.

Recommended Action    No action is required.

SPAN-5

Error Message     SPAN-5-ATL_VSAN_DEFAULT_ALL: Default to all VSANs for SPAN egress 
session 

Explanation    Generation 2 fabric switches support only one VSAN filter for egress SPAN session. If no or more than one VSANs are specified, SPAN will default to use all VSANs for the egress SPAN session

Recommended Action    No action is required.

Error Message     SPAN-5-SPAN_CFG_REJECT_SRC_VSAN_FILTER_NOT_SUPPORTED: Source 
interface [[chars]] in dir [[chars]] removed from session [[dec]]. 

Explanation    Interface level VSAN filters is not supported

Recommended Action    No action is required.

Error Message     SPAN-5-SPAN_CFG_REJECT_VSAN_SRC_PRESENT: Source VSAN [[dec]] removed 
from session [[dec]]. 

Explanation    Source VSANs are removed from the session as mixing of interface and VSANs is not supported.

Recommended Action    No action is required.

Error Message     SPAN-5-SPAN_PSS_CORRUPTION: Span is starting stateless due to PSS 
corruption 

Explanation    Due to unrecoverable PSS corruption error, SPAN starts stateless without any configuration

Recommended Action    No action is required.

Error Message     SPAN-5-STATELESS_RESTART_ON_ACTIVE: Span is restarting as Span on 
active sup was restarted stateless. 

Explanation    Due to unrecoverable error, Span on active supervisor was restarted stateless. So, the standby Span restarts to get in sync with the stateless Span on active.

Recommended Action    No action is required.

Error Message     SPAN-5-STATELESS_RESTART: Span is restarting stateless. 

Explanation    Due to unrecoverable error, Span is starting stateless. The currently active sessions will not be preserved. The user will have to reenter all the configuration.

Recommended Action    No action is required.

SPAN-6

Error Message     SPAN-6-SESSION_DOWN: Session [dec] is inactive ([chars]) 

Explanation    Session [dec] is inactive now. Traffic for this session is no longer spanned

Recommended Action    Check the reason for session inactive using command 'show span session' and take corresponding action.

Error Message     SPAN-6-SESSION_UP: Session [dec] is active, destination SD port 
[chars] 

Explanation    Session [dec] is active now. You can monitor Spanned traffic at the destination SD port

Recommended Action    No action is required.

Error Message     SPAN-6-STATELESS_SWITCHOVER: Span is starting stateless after 
switchover. 

Explanation    Active sessions are not preserved across switchover. Span is starting stateless and the configuration will be reapplied to get back the active configuration.

Recommended Action    No action is required.

SPI Messages

This section contains the SPI messages.

SPI-SLOT#-2

Error Message    SPI-SLOT#-2-SPI_INFO: [chars] 

Explanation    SPI Informational message

Recommended Action    No action is required.

STP Messages

This section contains the STP messages.

STP-2

Error Message    STP-2-BLOCK_BPDUGUARD: Received BPDU on port [chars] with BPDU Guard 
enabled. Disabling port. 

Explanation    A BPDU was received in the interface specified in the error message that has the spanning tree BPDU Guard feature enabled. As a result, the interface was administratively shut down.

Recommended Action    Either remove the device sending BPDUs or disable the BPDU Guard feature. The BPDU Guard feature can be locally configured on the interface or globally configured on all ports that have portfast enabled. After the conflict has been resolved, re-enable the interface by entering the <CmdBold>no shutdown<NoCmdBold> command in interface configuration mode.

Error Message     STP-2-BLOCK_DETECTED_PVST_PEER: Blocking port [chars] [PVST peer 
detected]. 

Explanation    The listed interface received SSTP BPDU indicating that peer is running PVST and will be held in spanning tree blocking state until the interface stops receiving SSTP BPDUs

Recommended Action    Either enable PVST simulation configuration for the interface or make sure the port peer is not PVST switch

Error Message     STP-2-BLOCK_PVID_LOCAL: Blocking [chars] on [chars]. Inconsistent 
local vlan. 

Explanation    The spanning tree port associate with the listed spanning tree instance and interface will be held in spanning tree blocking state until the Port VLAN ID (PVID) inconsistency is resolved. The listed spanning tree instance is that of the native VLAN id of the listed interface.

Recommended Action    Verify that the configuration of the native VLAN id is consistent on the interfaces on each end of the 802.1Q trunk connection. Once corrected, spanning tree will automatically unblock the interfaces as appropriate.

Error Message     STP-2-BLOCK_PVID_PEER: Blocking [chars] on [chars]. Inconsistent peer 
vlan. 

Explanation    The spanning tree port associate with the listed spanning tree instance and interface will be held in spanning tree blocking state until the port VLAN Id (PVID) inconsistency is resolved. The listed spanning tree instance is that of the native VLAN id of interface on the peer switch to which the listed interface is connected.

Recommended Action    Verify that the configuration of the native VLAN id is consistent on the interfaces on each end of the 802.1Q trunk connection. Once corrected, spanning tree will automatically unblock the interfaces as appropriate.

Error Message     STP-2-BRIDGE_ASSURANCE_BLOCK: Bridge Assurance blocking port [chars] 
[chars]. 

Explanation    BPDUs were not received from a neighboring switch on the interface that has spanning tree Bridge Assurance configured. As a result, the interface was moved to the spanning tree Blocking state

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-BRIDGE_ASSURANCE_UNBLOCK: Bridge Assurance unblocking port 
[chars] [chars]. 

Explanation    The interface listed in the message has been restored to normal spanning tree state after receiving BPDUs from the neighboring L2 switch/bridge

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-DISPUTE_CLEARED: Dispute resolved for port [chars] on [chars]. 

Explanation    The listed interface has stopped receiving Inferior BPDUs with designated role and state as learning and/or forwarding. The Dispute has been resolved and if the port is still designated, it will be taken out of the blocking state as and when appropriate.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-DISPUTE_DETECTED: Dispute detected on port [chars] on [chars]. 

Explanation    The spanning tree has detected a Dispute on this interface. The BPDU received from the peer is Inferior with designated role and state as learning and/or forwarding. Since this condition could be caused by an unidirectional link failure, the interface is put into blocking state and marked as disputed in order to prevent possible loops from being created

Recommended Action    Issue the <CmdBold>show spanning-tree inconsistentports<noCmdBold> command to review the list of interfaces with Dispute. Dispute is caused if the peer in not receiving the Superior BPDUs sent by this interface. That is why the peer continues to send its own Inferior BPDUs. Determine why devices connected to the listed ports are not receiving BPDUs. One reason could be a failure in the cable: if the link has a failure that makes it unidirectional (you can not transmit but you can receive) it should be replaced with a proper cable.

Error Message     STP-2-IPC_PROCESSING_ERR: Error in processing IPC message : Opcode = 
[dec], Error code = [hex] 

Explanation    STP encountered an error in processing an MTS message. The error and message are specified in the error message

Recommended Action    No action is required.

Error Message     STP-2-LOOPGUARD_BLOCK: Loop guard blocking port [chars] on [chars]. 

Explanation    The spanning tree message age timer has expired because and no BPDUs were received from the designated bridge. Since this condition could be caused by an unidirectional link failure, the interface is put into blocking state and marked as loop guard inconsistent in order to prevent possible loops from being created

Recommended Action    Issue the <CmdBold>show spanning-tree inconsistentports<noCmdBold> command to review the list of interfaces with loop guard inconsistencies. Determine why devices connected to the listed ports are not sending BPDUs. One reason could be that they do not run the spanning tree protocol; in this case you should disable loopguard in the inconsistent interface/s or start the spanning tree protocol on the other side of the link/s.depending on the context. Another reason could be a failure in the cable: if the link has a failure that makes it unidirectional (you can transmit but you can not receive) it should be replaced with a proper cable.

Error Message     STP-2-LOOPGUARD_CONFIG_CHANGE: Loop guard [chars] on port [chars]. 

Explanation    The spanning tree loopguard configuration for the listed interface has been changed. If enabled, the interface will be put into blocking state and marked as loopguard inconsistent when the message age timer expires because no BPDU were received from the designated bridge. This feature is mainly used to detect unidirectional links

Recommended Action    Verify that this is the desired configuration for the listed interface. Correct it if this is not the desired configuration otherwise no further action is required.

Error Message     STP-2-LOOPGUARD_UNBLOCK: Loop guard unblocking port [chars] on 
[chars]. 

Explanation    The listed interface has received a BPDU and therefore if the inconsistency was due to an unidirectional link failure, now the problem is not there anymore. The loop guard inconsistency is cleared for the interface which is taken out of the blocking state if appropriate.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-PVSTSIM_FAIL: Blocking [chars] port [chars]: Inconsistent 
[chars] PVST BPDU received on VLAN [dec], claiming root [chars]

Explanation    When a MST switch is connected to a PVST+ switch, the CIST (MST00) information on the port of the MST switch must be consistently better than all the PVST+ messages if the port is designated or consistently worse than all the PVST+ messages if the port is root. If this constraint is not respected, the port on the MST switch is blocked in order to prevent a potential bridging loop

Recommended Action    When STP is converging after a new switch, or switch port is added to the topology, this condition may happen transiently. The port unblocks automatically in such cases. If the port remains blocked, identify the root bridge as reported in the message, and configure a worse or better priority for the VLAN spanning tree consistent with the CIST role on the port of the MST switch. There could be more inconsistencies than the message indicates, and the port will not recover until all such inconsistencies are cleared. If you cannot determine which other VLANs have inconsistencies, disable and reenable the port. This message will appear again and specify another VLAN with inconsistencies to be fixed. Repeat this process until all inconsistencies on all VLANs are cleared.

Error Message     STP-2-PVSTSIM_OK: PVST Simulation inconsistency cleared on port 
[chars]. 

Explanation    The listed interface is no longer receiving PVST BPDUs advertising an information inconsistent with the CIST port information. The PVST Simulation Inconsistency is cleared and the interface returns to normal operation

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on [chars] 
[chars]. 

Explanation    The list interface received a SSTP BPDU that was missing the VLAN id tag. The BPDU is discarded.

Recommended Action    No action is required.

Error Message     STP-2-RECV_PVID_ERR: Received BPDU with inconsistent peer vlan id 
[dec] on [chars] [chars]. 

Explanation    The listed interface received a SSTP BPDU that is tagged with a VLAN id that does not match the VLAN id on which the BPDU was received. This occurs when the native VLAN is not consistently configured on both ends of a 802.1Q trunk.

Recommended Action    Verify that the configuration of the native VLAN id is consistent on the interfaces on each end of the 802.1Q trunk connection. Once corrected, spanning tree will automatically unblock the interfaces as appropriate.

Error Message     STP-2-ROOTGUARD_BLOCK: Root guard blocking port [chars] on [chars]. 

Explanation    A BPDU was received on the listed interface which advertizes a superior spanning tree root bridge to that currently in use. The interface is put into blocking state and marked as root guard inconsistent in order to prevent a suboptimal spanning tree topology to form.

Recommended Action    Issue the <CmdBold>show spanning-tree inconsistentports<noCmdBold> command to review the list of interfaces with root guard inconsistencies. Determine why devices connected to the listed ports are sending BPDUs with a superior root bridge and take action to prevent further occurances. Once the bogus BPDUs have been stopped, the interfaces will automatically recover and resume normal operation. Make sure that it is appropriate to have root guard enabled on the interface.

Error Message     STP-2-ROOTGUARD_CONFIG_CHANGE: Root guard [chars] on port [chars]. 

Explanation    The spanning tree root guard configuration for the listed interface has been changed. If enabled, any BPDU received on ths interface which advertizes a superior spanning tree root bridge to that already in use will cause the interface to be put into blocking state and marked as root guard inconsistent.

Recommended Action    Verify that this is the desired configuration for the listed interface. Correct it if this is not the desired configuration otherwise no further action is required.

Error Message     STP-2-ROOTGUARD_UNBLOCK: Root guard unblocking port [chars] on 
[chars]. 

Explanation    The listed interface is no longer receiving BPDUs advertizing a superior root bridge. The root guard inconsistency is cleared for the interface and then it is taken out of the blocking state if appropriate.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-SET_PORT_STATE_FAIL: Port state change req to PIXM failed, 
status = [hex] [[chars]] vdc [dec], tree id [dec], num ports [dec], ports [chars] 
state [chars], opcode [chars], msg id ([dec]), rr_token [hex]

Explanation    The port set port state has failed. check port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-SET_PORT_STATE_TIMEOUT: Port state change req to PIXM timedout 
after [dec] sec. vdc [dec], tree id [dec], num ports [dec], ports [chars] state 
[chars], opcode [chars], msg id ([dec]), rr_token [hex]

Explanation    The port set port state has timedout. check port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-STP_INIT: STP initialization of [chars] [chars] 

Explanation    STP initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     STP-2-STP_ISSU_LC_RESET: STP resetting LC[dec] to prevent Loops 
during ISSU caused by a topology change in the network. Peer on [chars] [chars] 
could not be Disputed

Explanation    This can happen as a result of a topology change in the network while the Linecard was undergoing ISSU. Since STP cannot change the port state to blocking on the Linecard undergoing ISSU, it will first try to prevent the Loop by causing a Dispute on the peer ports forcing them into blocking state. But if the peer does not support Dispute mechanism, and STP detects a potential Loop, it will reset the Linecard to prevent the Loop

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-UNBLOCK_CONSIST_PORT: Unblocking port [chars] on [chars]. Port 
consistency restored. 

Explanation    The Port VLAN ID and/or Port Type inconsistencies have been resolved and spanning tree will now unblock the listed interface of the listed spanning tree instance as appropriate.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-UNBLOCK_DETECTED_PVST_PEER: Unblocking port [chars] [PVST peer 
detected]. 

Explanation    The listed interface has stopped receiving SSTP BPDUs and so will be restored to normal spanning tree state

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-VLAN_PORT_LIMIT_EXCEEDED: The number of vlan-port instances 
([dec]) exceeded [[chars] mode] recommended limit of [dec] 

Explanation    The total number of individual VLAN ports, in the spanning tree mode specified in the error message, has exceeded the limit specified in the error message. VLANs can be counted more than once; if VLAN 1 is carried on 10 interfaces, it will count as 10 VLAN ports. Note that bundling is ignored for purposes of this count; if 8 interfaces on the same module are in one bundle, and the port channel is carrying VLAN 1, it will count as 1 VLAN ports.

Recommended Action    Reduce the number of trunks and VLANs configured in the switch. Keep the VLAN port count below the recommended limit specified in the configuration documentation. Enter the <CmdBold>show interface trunk<NoCmdBold> command to see the total number of trunks and VLANs.

Error Message     STP-2-VPC_PEER_LINK_INCONSIST_BLOCK: vPC peer-link detected [chars] 
blocking [chars] [chars]. 

Explanation    VPC Peer-link detected the STP inconsistency mentioned in the message. This will impact the STP topology for vPCs and can cause frame duplications. As a result, the interface was moved to the spanning tree Blocking state

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-2-VPC_PEER_LINK_INCONSIST_ERRDISABLE: vPC Peer-link detected 
[chars]. Disabling [chars]. 

Explanation    VPC Peer-link detected the STP inconsistency mentioned in the message. This will impact the STP topology for vPCs and can cause frame duplications. As a result, the vPC Peer-link was administatively shut down.

Recommended Action    Please resolve the inconsistency reported in this message on the vPC Peer link. After the conflict has been resolved, re-enable the interface by entering the <CmdBold>no shutdown<NoCmdBold> command in interface configuration mode.

Error Message     STP-2-VPC_PEER_LINK_INCONSIST_UNBLOCK: vPC peer-link inconsistency 
cleared unblocking [chars] [chars]. 

Explanation    VPC Peer-link inconsistency is cleared and the vPC interface listed in the message has been restored to normal spanning tree state.

Recommended Action    LOG_STD_NO_ACTION

STP-3

Error Message     STP-3-BLOCK_PORT_TYPE: Blocking [chars] on [chars]. Inconsistent port 
type. 

Explanation    The listed interface is being held in spanning tree blocking state until the port type inconsistency is resolved.

Recommended Action    Verify that the configuration and operational state of the listed interface and that of the interface to which it is connected have the same mode (access vs trunk). If mode is trunk, verify the same encapsulation (ISL, 802.1Q). Once these parameters are consistent, spanning tree will automatically unblock the interfaces as appropriate.

Error Message     STP-3-PORT_SELF_LOOPED: Received BPDU src mac same as that of port. 
Port self loopback detected. Port [chars] being disabled

Explanation    The source MAC address contained in a BPDU received on the listed interface matches the MAC address assigned to that interface This indicates the possibility that a port is looped back to itself, possibly due to a diagnostic cable being plugged in. The interface will be administratively shutdown.

Recommended Action    Check the interface configuration and any cable plugged into the interface. Once problem resolved, re-enable interface by doing a no shutdown in the interface configuration. Copy the error message as it is printed and also copy the output of a show interface for the interace listed in the error message.

Error Message     STP-3-RECV_1Q_NON_TRUNK: Received 802.1Q BPDU on non trunk [chars] 
[chars]. 

Explanation    A SSTP BPDU was received on the listed interface that was not operationally a trunk.

Recommended Action    Verify that the configuration and operational state of the listed interface and that of the interface to which it is connected have the same mode (access vs trunk). If mode is trunk, verify the same encapsulation (none, ISL, 802.1Q). Once these parameters are consistent, spanning tree will automatically unblock the interfaces as appropriate.

STP-4

Error Message     STP-4-FORWARDTIME_CONFIG_CHANGE: Forward Delay time change to [dec] 
seconds for instance [chars] is not recommended as it can cause STP data loops 
during High Availability Dual-Supervisor Switchover and In-Service Software 
Upgrade

Explanation    It is stongly recommended to avoid changing forward delay time value to less than the default value of 15 seconds since it can cause STP data loops during High Availability Dual-Supervisor Switchover and also during In-Service Software Upgrade. Please read the release notes.

Recommended Action    Please change the forward delay time to be greater than or equal to the default value of 15 seconds

Error Message     STP-4-HELLOTIME_CONFIG_CHANGE: Hello time change to [dec] seconds for 
instance [chars] is not recommended as it can trigger STP Topology Changes during 
High Availability Dual-Supervisor Switchover and In-Service Software Upgrade

Explanation    It is stongly recommended to avoid changing Hello time value to less than the default value of 2 seconds since it can trigger STP Topology change during High Availability Dual-Supervisor Switchover and also during In-Service Software Upgrade. Please read the release notes.

Recommended Action    Please change the hello time to be greater than or equal to the default value of 2 seconds.

Error Message     STP-4-MAC_ADDR_FLUSH_REQ_TIMEOUT: MAC Address Flush req to L2FM 
timedout after [dec] sec. vdc [dec], tree id [dec], num ports [dec], ports [chars], 
opcode [chars], msg id ([dec]), rr_token [hex]

Explanation    The MAC Address Flush Request to L2FM has timedout. check port

Recommended Action    LOG_STD_NO_ACTION

STP-6

Error Message     STP-6-FIRST_BPDU_TX: First BPDU transmitted 

Explanation    First BPDU transmitted.

Recommended Action    No action is required.

Error Message     STP-6-MST_DIGEST: MST digest changed to [chars], pre-std digest 
changed to [chars] 

Explanation    MST Region configuration has changed

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-MST_PORT_BOUNDARY: Port [chars] [chars] as MST Boundary port 

Explanation    MST Boundary port status of the specified port is changed

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-MST_PORT_PRE_STANDARD: Port [chars] [chars] as MST Pre-standard 
port. 

Explanation    MST pre-standard status of the specified port is changed

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_ADDED: Interface [chars], added to [chars] with role 
[chars], state [chars], cost [dec], priority [dec], link-type [chars] 

Explanation    This spanning tree port has been added

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_COST: Port [chars] instance [chars] cost changed to [dec] 

Explanation    The spanning tree port cost has changed for the specified port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_DELETED: Interface [chars], removed from [chars] 

Explanation    This spanning tree port has been deleted

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_LINK_TYPE: Port [chars] instance [chars] link changed to 
[chars] 

Explanation    The spanning tree port link type has changed for the specified port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_PRIORITY: Port [chars] instance [chars] priority changed 
to [dec] 

Explanation    The spanning tree port priority has changed for the specified port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_ROLE: Port [chars] instance [chars] role changed to [chars] 

Explanation    The spanning tree port role has changed for the specified port

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PORT_STATE: Port [chars] instance [chars] moving from [chars] 
to [chars] 

Explanation    The Spanning-Tree port has changed state.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-PRESTD_NEIGH: This switch has received a pre-standard MST BPDU 
on port [chars]: Invoking pre-standard MST BPDU transmission on this port.

Explanation    The switch has received a pre-standard MST BPDU on a port. The switch will automatically adjust its mode of operation on this port and will start sending pre-standard BPDUs.

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-ROOT: Root bridge for [chars] changed to [chars] 

Explanation    The spanning tree root bridge has changed

Recommended Action    LOG_STD_NO_ACTION

Error Message     STP-6-SERVICE_UP: Initialized [chars] 

Explanation    STP line 2.

Recommended Action    No action is required.

Error Message     STP-6-STATE_CREATED: Internal state created [chars] 

Explanation    STP has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

SVC_BATTERY Messages

This section contains the SVC_BATTERY messages.

SVC_BATTERY-SLOT#-2

Error Message    SVC_BATTERY-SLOT#-2-BATTERY_NOT_OPERATIONAL: Battery [dec] 
temperature [dec] C is outside the operational range (-10C to 65C).

Explanation    The battery temperature is outside the operational range (-10C to 65C).

Recommended Action    Verify fan operation with [show environment fan], and take action to cool down the switch.

Error Message     SVC_BATTERY-SLOT#-2-BATTERY_NOT_PRESENT: Battery [dec] is not 
present. 

Explanation    The line card does not have sufficient number of batteries. Two batteries are needed.

Recommended Action    Remove the line card and plug in batteries in the battery slots that are empty.

Error Message     SVC_BATTERY-SLOT#-2-CHARGING_DISABLED: Temperature outside permitted 
range for battery charging (5C-40C).

Explanation    The temperature of the linecard is not within the range to permit battery charging.

Recommended Action    Make sure the temperature of the linecard is between 5C and 40C

Error Message     SVC_BATTERY-SLOT#-2-CHARGING_FAILURE: Charging failure in battery 
[dec] ([hex]). 

Explanation    The module encountered failures while charging a battery.

Recommended Action    Replace the battery.

Error Message     SVC_BATTERY-SLOT#-2-CLOCK_INCORRECT: System clock is running behind, 
battery conditioning will be affected.

Explanation    The Vegas system clock is running behind the actual time. This will affect the battery conditioning.

Recommended Action    Use clock set CLI command to set the correct time

Error Message     SVC_BATTERY-SLOT#-2-COMMUNICATION_FAILURE: Communication failure 
with battery [dec]. 

Explanation    The module encountered failures while communicating with a battery.

Recommended Action    Replace the battery.

Error Message     SVC_BATTERY-SLOT#-2-CONDITIONING_DISABLED: Temperature outside 
permitted range for battery conditioning (5C-40C).

Explanation    The temperature of the linecard is not within the range to permit battery conditioning.

Recommended Action    Make sure the temperature of the linecard is between 5C and 40C

Error Message     SVC_BATTERY-SLOT#-2-DISCHARGING_FAILURE: Discharging failure in 
battery [dec] ([hex]). 

Explanation    The module encountered failures while discharging a battery.

Recommended Action    Replace the battery.

SVC_BATTERY-SLOT#-4

Error Message     SVC_BATTERY-SLOT#-4-BATTERY_CAPACITY_LOW: Battery capacity is below 
the required threshold. 

Explanation    The battery is lower than the required threshold.

Recommended Action    Make sure the temperature is within the range to allow charging.

SVC_BATTERY-SLOT#-6

Error Message     SVC_BATTERY-SLOT#-6-BATTERY_CAPACITY_OK: Battery capacity is above 
the required threshold. 

Explanation    The battery is above the required threshold.

Recommended Action    No action is required.

Error Message     SVC_BATTERY-SLOT#-6-CONDITIONING_CANCELLED: Temperature outside 
permitted range for battery conditioning (5C-40C). Battery [dec] conditioning 
cancelled.

Explanation    The temperature of the linecard is not within the range to permit battery conditioning.

Recommended Action    Make sure the temperature of the linecard is between 5C and 40C

Error Message     SVC_BATTERY-SLOT#-6-CONDITIONING_COMPLETED: Conditioning of battery 
[dec] completed successfully. 

Explanation    Conditioning process started for a battery is completed successfully.

Recommended Action    No action is required.

Error Message     SVC_BATTERY-SLOT#-6-CONDITIONING_RESUMED: Conditioning of battery 
[dec] resumed. 

Explanation    Conditioning process for a battery is resumed.

Recommended Action    No action is required.

Error Message     SVC_BATTERY-SLOT#-6-CONDITIONING_STARTED: Conditioning of battery 
[dec] started. 

Explanation    Conditioning process started for a battery

Recommended Action    No action is required.

SVC Messages

This section contains the SVC messages.

SVC-0

Error Message    SVC-0-NODE_EMERG_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

SVC-1

Error Message     SVC-1-NODE_ALERT_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

SVC-2

Error Message     SVC-2-NODE_CRIT_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

Error Message     SVC-2-SVC_SYSLOG_INIT_FAILED: Initialization failed for SVC: [chars], 
Reason: [hex] 

Explanation    Initialization failed for SVC

Recommended Action    No action is required.

Error Message     SVC-2-SVC_SYSLOG_NO_PORT_CHAN: Too many PortChannels allocated by 
user for interface [chars] 

Explanation    SVC interface needs PortChannels to operate. Too many PortChannels have been allocated by the user for the interface to operate correctly.

Recommended Action    Please delete unneeded user configured PortChannels and shutdown the SVC interface. Once complete, please bring the SVC interface back up.

Error Message     SVC-2-SVC_SYSLOG_PATH_FAILURE: System health detected SVC packet path 
failure for [chars]. 

Explanation    The CSM has been brought down by the System Health monitor. System Health has detected a failure in the packet path between the SVC interface on the CSM and the backplane. This System Health test is run periodically.

Recommended Action    Issue a no shutdown on the SVC interface to bring the node back online. If a subsequent packet path failure occurs, the CSM module should be replaced.

Error Message     SVC-2-SVC_SYSLOG_URIFS_FAILURE: [chars] is unreachable for reason: 
[chars] 

Explanation    SVC interface modflash is not accessable. Modflash is the name of the filesystem local to the SVC interface, and is typically used for coredumps and temporary file transfers.

Recommended Action    Please shutdown and bring up the SVC interface in question to regain access to the modflash filesystem.

SVC-3

Error Message     SVC-3-NODE_ERR_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_ACTIVATE_CLUSTER_IP_FAILED ) Activate cluster IP failed [chars] 

Explanation    Unable to activate the cluster IP for the config node. It will not be possible to execute configuration commands.

Recommended Action    1. Shutting the interfaces of the node will force this node out of the cluster and cause another node to become the config node, which should restore the ability to execute configuration commands. 2. If the error persists, re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code. 4. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_FAILURE ) 
Battery Failed [chars] 

Explanation    The battery module on the Caching Services Module has failed. The nodes on the CSM will have shutdown. Other log entries may accompany this error.

Recommended Action    Reload the Caching Services Module. If the error persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_DISK_FAILURE ) 
Internal Disk Drive Failed [chars] 

Explanation    The internal disk drive for the node on the Caching Services Module has failed. The node will have shutdown. Other log entries may accompany this error.

Recommended Action    Reload the Caching Services Module. If the error persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_DUMP_RESTORE_FAILED ) Restore of hardened data failed [chars] 

Explanation    Restore of customer data failed. This error will be accompanied by other log entries.

Recommended Action    Examine the log for other error entries and follow the actions recommended. If no other entries are found: 1. Re-install the code on the node. The node will have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_INVALID_BATT_CAPACITY ) Get battery capacity failed [chars] 

Explanation    The process was unable to get the battery capacity. Possibly due to communication failures with the CPP processor in the line card. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the line card. The node(s) will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_OPEN_COMMITTED_FILE_FAILED ) Error attempting to open file [chars] 

Explanation    Process was unable to open the committed file. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_SET_BATT_THRESHOLD_FAILED ) Set battery threshold failed [chars] 

Explanation    The process was unable to set the battery threshold. Possibly due to fatal communication failures with the power management module in the line card or the power management module has crashed. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the line card. The node(s) will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_IC_EV_NODE_DISENFRANCHISED ) Node missing [chars] 

Explanation    A node is missing from the cluster.

Recommended Action    1. If it is not obvious which node in the cluster has failed, check the status of the nodes and find the node with a status of offline. 2. Repair the failing node. 3. When the repair has been completed, this error will automatically be marked as fixed. 4. Check the node status. If all the nodes in the cluster are now online, but the error in the log has not been marked as fixed, manually mark the error as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_PL_ER_CLUSTER_PATH_FAILURE ) Cluster path failure [chars] 

Explanation    A cluster path has failed. The node is unable communicate with all the other nodes in the cluster.

Recommended Action    1. Repair the fibre-channel network fabric. 2. Check the status of the node port. If the status of the port shows as online, mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_CPU_QUANTITY ) 
Processor change detected [chars] 

Explanation    The Caching Services Module is failing.

Recommended Action    1. Replace the Caching Services Module. 2. Check node status. If all nodes show a status of online, mark the error you have just repaired fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_DISK_FULL ) Node 
hard disk full [chars] 

Explanation    The error that is logged in the cluster error log indicates a software problem in the cluster.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Delete files from the /dumps directory. 3. Run a configuration dump and a logged data dump. Save the dump data. 4. Ask IBM Product Support for assistance. 5. Mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_FAIL ) 
Logical Fibre Channel port reported failed [chars] 

Explanation    No active/functioning logical FC port was detected by the software.

Recommended Action    Reload the node. If the problem persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_QUANTITY ) 
Logical Fibre Channel port missing [chars] 

Explanation    No active/functioning FC port was detected by the software.

Recommended Action    Reload the node. If the problem persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_PORT_QUANTITY ) 
Logical Fibre Channel port reported not operational [chars] 

Explanation    No active/functioning logical FC port was detected by the software.

Recommended Action    Reload the node. If the problem persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_NODE_WARMSTART ) 
Node warmstarted due to software error [chars] 

Explanation    The error that is logged in the cluster error log indicates a software problem in the cluster.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Run a configuration dump and a logged data dump. Save the dump data. 3. Ask IBM Product Support for assistance. 4. Mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_POWER_DOMAIN ) 
Power domain error [chars] 

Explanation    The two nodes in an IO group are on the same Caching Services Module.

Recommended Action    Determine what the configuration should be. Remove one of the nodes and add a node to the IO group which is not on the same Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VG_ER_MDISK_GROUP_OFFLINE ) A Managed Disk group is offline [chars] 

Explanation    An Mdisk group is offline.

Recommended Action    1. Repair the enclosure or disk controller. 2. Start a cluster discovery operation. 3. Check managed disk status. If all managed disks show a status of online, mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VG_ER_MED_ERRS_TOO_HIGH 
) Media errors on back-end Managed Disk [chars] 

Explanation    Media errors on backend managed disk.

Recommended Action    1. Repair the enclosure or disk controller. \ 2. Include the managed disk into the cluster. 3. Check managed disk status. If all managed disks show a status of online, mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_BASE_EVENT_RESOURCE_RAN_OUT ) Software error [chars] 

Explanation    The error that is logged in the cluster error log indicates a software problem in the cluster.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Run a configuration dump and a logged data dump. Save the dump data. 3. Ask IBM Product Support for assistance. 4. Mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_CONTROLLER_CONFIG_INVALID ) Incorrect controller configuration 
[chars] 

Explanation    Incorrect disk controller configuration.

Recommended Action    1. Using service documentation for the disk controller, check that the correct configuration is set up for the disk controller. See also the IBM TotalStorage SAN Volume Controller for Cisco MDS 9000: Configuration Guide. 2. Mark the error you have just repaired as fixed. 3. Start a cluster discovery operation.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_DEVICE_PORT_LOGIN_LOSS ) Number of controller logins reduced [chars] 

Explanation    The number of controller logins has been reduced. One possible cause is that the user intentionally reconfigured the system.

Recommended Action    1. Check whether the controller has regained connectivity. If it has not, check the cable connection to the remote-device port. 2. If all logins to a remote-device port have failed and you cannot solve the problem by changing cables, check the condition of the remote-device port and the condition of the remote device. 3. Start a cluster discovery operation. 4. Check the status of the disk controller. If all disk controllers show a good status, mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_DEVICE_RESOURCE_RAN_OUT ) Too many controllers were presented to the 
cluster [chars] 

Explanation    The configuration is not valid. Too many devices have been presented to the cluster or node.

Recommended Action    1. Remove unwanted devices from the fibre-channel network fabric. 2. Start a cluster discovery operation to find devices. 3. List all connected managed disks. Check with the customer that the configuration is as expected. Mark the error you have just repaired fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_ERP ) Error 
Recovery Procedure occurred [chars] 

Explanation    A managed disk error recovery procedure (ERP) has occurred. This error has been reported because a large number of disk error recovery procedures have been performed by the disk controller. The problem is probably caused by a failure of some other component on the SAN.

Recommended Action    1. View the error log entry and determine the managed disk that was being accessed when the problem was detected. (Note that the sense data from the disk controller is recorded in the cluster error log and can be accessed there. This data is not available in the switch system log.) 2. Perform the disk controller problem determination and repair procedures for the mdisk determined in step 1. 3. Perform fibre channel switch problem determination and repair procedures for the fibre channel switches containing the node, and connected to the disk controller that is managing the mdisk, and any fibre channel switches in the fibre channel path between those switches. 4. If any problems are found and resolved in steps 2 and 3, mark this error as fixed. 5. If no switch or disk controller failures were found in steps 2 and 3, take an error log dump. Call your hardware support center.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_ERROR ) Managed 
Disk I/O error [chars] 

Explanation    A managed disk or managed disk controller port has been excluded because of excessive errors or unusual behavior.

Recommended Action    1. Repair the enclosure or disk controller. 2. Check the managed disk status. If any managed disks show a status of online, mark the error you have just repaired as fixed. If any managed disks show a status of excluded, included the managed disks and then mark the error as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_THRESHOLD ) 
Managed Disk error count threshold exceeded [chars] 

Explanation    A managed disk or managed disk controller port has been excluded because of excessive errors or unusual behavior.

Recommended Action    1. Repair the enclosure or disk controller. 2. Check the managed disk status. If any managed disks show a status of online, mark the error you have just repaired as fixed. If any managed disks show a status of excluded, included the managed disks and then mark the error as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_TIMEOUT_OVERALL 
) Timeout due to excessive processing time [chars] 

Explanation    A managed disk has timed out. This error has been reported because a large number of disk timeout conditions have been detected. The problem is probably caused by a failure of some other component on the SAN.

Recommended Action    1. Repair problems on all disk controllers and switches on the same SAN as this cluster. 2. If problems are found, mark this error as fixed. 3. If no switch or disk controller failures can be found, take an error log dump and call your hardware support center.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_LOCAL_PORT_EXCLUDED ) Local FC port excluded [chars] 

Explanation    A local fibre-channel port has been excluded.

Recommended Action    1. Repair the fibre-channel network fabric. 2. Check the status of the disk controller. If all disk controllers 3. show good status, mark the error you have just repaired fixed. 4. If the error persists and no other cause can be determined, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_LOGIN_EXCLUDED ) 
Login excluded [chars] 

Explanation    Login has been excluded.

Recommended Action    1. In the sequence shown, exchange the FRUs for new FRUs: Fibre Channel cable, switch to remote port. 2. Start a cluster discovery operation to recover the login. 3. Check the status of the disk controller. If all disk controllers show a good status, mark the error you have just repaired fixed. 4. If the error persists and no other cause can be determined, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_LUN_RESOURCE_RAN_OUT ) Too many LUNs were presented to a node [chars] 

Explanation    The configuration is not valid. Too many devices have been presented to the cluster or node.

Recommended Action    1. Remove unwanted devices from the fibre-channel network fabric. 2. Start a cluster discovery operation to find devices. 3. List all connected managed disks. Check with the customer that the configuration is as expected. Mark the error you have just repaired fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_MDISK_ACCESS_INVALID ) Access beyond end of disk, or Managed Disk 
missing [chars] 

Explanation    The error that is logged in the cluster error log indicates a software problem either in the cluster, or in a disk enclosure or disk controller that is connected to the node.

Recommended Action    1. Ensure that the software is at the latest level on the cluster and on the disk controllers. 2. Run a configuration dump and a logged data dump. Save the dump data. 3. Ask IBM Product Support for assistance. 4. Mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_MDISK_DEVICE_PORT_EXCLUDED ) Remote Port excluded for a specific 
Managed Disk and Node [chars] 

Explanation    A remote fibre-channel port has been excluded.

Recommended Action    1. View the error log. Note the mdisk ID associated with the error code. 2. Using the mdisk ID, determine the failing disk controller. 3. Refer to the service documentation for the disk enclosure or disk controller and the fibre-channel network fabric to resolve the reported problem. 4. Start a cluster discovery operation to recover the excluded fibre-channel port. 5. Include the managed disk that you noted in step 1. 6. Check the status of the disk controller. If all disk controllers show a good status, mark the error you have just repaired fixed. 7. If all disk controllers do not show a good status, contact the IBM support center to resolve the problem with the disk controller.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_MDISK_EXCLUDED ) 
Managed Disk excluded due to excessive errors, or all device ports excluded [chars] 

Explanation    A managed disk or managed disk controller port has been excluded because of excessive errors or unusual behavior.

Recommended Action    1. Repair the enclosure or disk controller. 2. Check the managed disk status. If any managed disks show a status of online, mark the error you have just repaired as fixed. If all managed disks show a status of excluded, included the managed disks and then mark the error as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_MDISK_INITIALISE_INVALID ) Invalid blocksize, capacity or LUN 
identity has changed during Managed Disk initialisation [chars] 

Explanation    Access beyond end of disk. The initialization of the managed disk has failed.

Recommended Action    1. Check the status of the managed disk and of the managed-disk group. 2. Include the managed disk into the cluster. 3. Check the managed disk status. If all managed disks show a status of online, mark the error you have just repaired as fixed. 4. If not all managed disks show a status of online, check the status of the disk controller.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_MDISK_RESOURCE_RAN_OUT ) Too many Managed Disks were presented to the 
cluster [chars] 

Explanation    The configuration is not valid. Too many devices have been presented to the cluster or node.

Recommended Action    1. Remove unwanted devices from the fibre-channel network fabric. 2. Start a cluster discovery operation to find devices. 3. List all connected managed disks. Check with the customer that the configuration is as expected. Mark the error you have just repaired fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_QUORUM_DISK_CREATION_FAILURE ) A suitable Managed Disk for use as a 
Quorum Disk was not found [chars] 

Explanation    No Mdisk is suitable for use as a quorum disk. When a cluster is created three disks are automatically selected as quorum disks. A quorum disk is needed to enable a tie-break when some cluster members are missing. To become a quorum disk: The Mdisk must be accessible by all nodes in the cluster and the Mdisk must have free extents. This error code is produced when at least one quorum disk is not accessible by all nodes in the cluster. A quorum disk might not be available because of a fibre-channel network failure or because of a fibre-channel switch zoning problem.

Recommended Action    1. Resolve any known fibre-channel network problems. 2. Ask the customer to confirm that Mdisks have been created and that those mdisks have free extents. 3. List the manage disks. If at least one managed disk shows a mode of managed, mark the error you have just repaired as fixed. 4. If the customer is unable to make the appropriate changes, ask IBM Software Support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_QUORUM_DISK_NOT_AVAILABLE ) Quorum Disk not available [chars] 

Explanation    One or more quorum disks were not discovered by the node.

Recommended Action    1. Resolve any known fibre-channel network problems. 2. Check managed disk status. If any managed disks are offline or excluded perform the disk controller problem determination and repair procedures for the managed disks. 3. Start a cluster discovery operation. 4. Check managed disk status. If all managed disks show a status of online, mark the error you have just repaired as fixed.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ALL_SSH_KEYS_REMOVED 
) Attempt to delete SSH keys (no effect) [chars] 

Explanation    'svctask rmallsshkeys' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_CREATEPARTNERSHIP ) Remote Copy partnership created [chars] 

Explanation    'svctask mkpartnership' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_DELETEPARTNERSHIP ) Remote Copy partnership deleted [chars] 

Explanation    'svctask rmpartnership' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_MODIFYPARTNERSHIP ) Remote Copy partnership modified [chars] 

Explanation    'svctask chpartnership' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_SSH_KEY_ADDED ) 
Attempt to add SSH key (no effect) [chars] 

Explanation    'svctask addsshkey' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_SSH_KEY_REMOVED ) 
Attempt to delete SSH key (no effect) [chars] 

Explanation    'svctask rmsshkey' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_CR_START ) Cluster 
recovery required [chars] 

Explanation    The node has detected that cluster recovery is required and is waiting for for human intervention to continue.

Recommended Action    Contact IBM Product support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_CORRUPT ) Node 
data corrupted - node rejected from cluster [chars] 

Explanation    Node data is readable but corrupted. The node has been rejected from the cluster.

Recommended Action    1. Re-install the code on the node. The node will have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_UNREADABLE ) Node 
data unreadable - node rejected from cluster [chars] 

Explanation    Node data could not be read. The node has been rejected from the the from cluster.

Recommended Action    1. Re-install the code on the node. The node will have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_HDW_CONFIG ) Processor 
not valid [chars] 

Explanation    The node has detected unexpected differences in the processor vital data.

Recommended Action    Reload the node. If the problem persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_MEM_SIZE ) Memory size 
error [chars] 

Explanation    The detected memory size does not match the expected memory size for the cluster.

Recommended Action    A memory module on the Cisco MDS 9000 Caching Services Module is probably faulty. Reload the node. If the error persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_MISSING_RES ) Unable 
to form a cluster due to lack of cluster resources [chars] 

Explanation    The node is unable to locate sufficient other nodes in the cluster and/or \ the quorum disk controller needed in order to form a cluster.

Recommended Action    Check the status of the quorum disk controller and the other nodes in the cluster. If the quorum disk has failed, perform the problem determination procedures for the disk \ controller. Otherwise perform problem determination on the missing nodes and network.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_NO_FABRIC ) The node 
is unable to see the FC fabric [chars] 

Explanation    No active/functioning logical FC port was detected by the software.

Recommended Action    Reload the node. If the problem persists, replace the Caching Services Module.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_PWR_DMN_ERR ) Power 
domain error [chars] 

Explanation    The two nodes in an IO group are on the same Caching Services Module.

Recommended Action    Determine if both nodes on the Caching Services Module are in fact in the same IO group. If so, determine what the configuration should be. Remove one of the nodes and add a node to the IO group which is not on the same Caching Services Module. If not, ask IBM Product Support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_REPEATED_ASSERTS ) 
Node repeatedly crashing due to a software fault [chars] 

Explanation    The number of software faults has exceeded the maximum allowed for the time period.

Recommended Action    1. Delete the node from the cluster. 2. Try to add the node back into the cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster with the latest level of code. 4. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_RESET_AND_REJECT ) 
Node data not found - node rejected from cluster [chars] 

Explanation    Node data was not found. The node has been rejected from the the from cluster.

Recommended Action    Examine error logs to determine if another recorded error caused the loss of the node data and, if so, follow the actions for that error. If no other error was recorded, the node may have lost power without saving data or been reset. Attempt to determine the cause of the power loss or reset. If no cause can be determined, then: 1. Re-install the code on the node. The node will have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the Caching Services Module.

Error Message     SVC-3-SVC_SYSLOG_IF_INTERNAL_ERROR: Interface [chars] internal error: 
[chars] 

Explanation    SVC interface internal error

Recommended Action    No action is required.

Error Message     SVC-3-SVC_SYSLOG_LC_INTERNAL_ERROR: Unable to send MTS to linecard in 
slot [dec]: [chars] 

Explanation    Linecard MTS failure

Recommended Action    No action is required.

Error Message     SVC-3-SVC_SYSLOG_NPORT_INTERNAL_ERROR: [chars] N-port for Interface 
[chars], vsan [dec] internal error: [chars] 

Explanation    N-port internal error

Recommended Action    No action is required.

SVC-4

Error Message     SVC-4-NODE_WARNING_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_CA_EV_FIRST_DATA_PINNED ) Customer data pinned [chars] 

Explanation    There is now pinned customer data. This warning is given when data is pinned and there wasn't already pinned data. Error log entries will exist for the underlying cause of the pinned data.

Recommended Action    Perform problem determintation on the error log to determine the cause of the pinned data and correct.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_CA_EV_HWS_TO_SYNCHRONOUS ) Cache in write through mode due to pinned data 
[chars] 

Explanation    The cache must now operate in write through mode because of the amount of pinned data.

Recommended Action    Perform problem determintation on the error log to determine the cause of the pinned data and correct.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_BATT_BELOW_CAPACITY ) Battery is below threshold capacity [chars] 

Explanation    Battery capacity is below threshold. The node will remain offline until the battery charge is sufficient to come up.

Recommended Action    Wait for the battery to recharge. This may take many hours. If after several hours have passed and the node has not yet come up: 1. Reload the node. 2. If the error persists, re-install the code on the line card. The node(s) will then have to be removed and re-added back to the cluster. 3. If the error persists, replace the Caching Services Module.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_CANNOT_OPEN_IO_PROCESS_Q ) Internal error - IO process queue [chars] 

Explanation    The process was unable to open the needed message queue. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_DEACTIVATE_CLUSTER_IP_FAILED ) Deactivate cluster IP failed [chars] 

Explanation    Unable to deactivate the cluster IP for the config node. The cluster IP should be deactivated by other checks. If that is not the case it may not be possible to execute configuration commands.

Recommended Action    If there is a problem executing configuration commands: 1. Shutting the interfaces of the node will force this node out of the cluster and should cause the switch to deactivate the IP address associated with this node which should restore the ability to execute configuration commands. \ 2. If the error persists, re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code. 4. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_DUMP_METADATA_FAILED ) Node assert dump failed [chars] 

Explanation    A failure occurred writting out a node assert dump. Other log entries may accompany this error.

Recommended Action    An initial error will have caused the node assert dump. Examine the log for that error and follow the recommended actions for that error. In addition examine the log for errors related to the internal disk drive. If found, follow the recommended actions. If no entries explain the failure to write the dump: 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the Caching Services Module.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED 
) Internal error - program launch [chars] 

Explanation    The process was unable to launch the IO program. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_FORK_FAILED ) 
Internal error - fork failed [chars] 

Explanation    The process was unable to launch the IO program. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_INTERNAL_EXIT_LOGIC_ERR ) Internal error - bad exit code [chars] 

Explanation    Node was warmstarted due to internal logic error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_INTERNAL_UNKNOWN_EXEC_MODE ) Internal error - run mode [chars] 

Explanation    Node was rebooted due to internal logic error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_IOP_EXITED_DUE_TO_SIGNAL ) Internal error - signal caused exit 
[chars] 

Explanation    The IO process exited because of a signal which was not caught. Node was warmstarted due to this error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_IOP_STOPPED_DUE_TO_SIGNAL ) Internal error - signal caused stop 
[chars] 

Explanation    The IO process stopped because of a signal received. Node was warmstarted due to this error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_IOP_TERMINATED_ABNORMALLY ) Internal error - abnormal exit [chars] 

Explanation    The IO process exited abnormally. Node was warmstarted due to this error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_OPEN_MSG_QUEUE_FAILED ) Internal error - message queue [chars] 

Explanation    The process was unable to open the needed message queue. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_PTHREAD_CREATE_FAILED ) Internal error - threads [chars] 

Explanation    The process was unable to create the needed threads. Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_UNKNOWN_MESSAGE_TYPE ) Internal error - message type [chars] 

Explanation    Node was rebooted due to internal logic error.

Recommended Action    1. Ensure that the software is at the latest level on the cluster. 2. Ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_WAITPID_FAILED 
) Internal error - waitpid failed [chars] 

Explanation    The process was unable to launch the IO program properly. Node was warmstarted due to this error.

Recommended Action    If this error is repeated continously, 1. Reload the node. 2. If the error persists, re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code. 4. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_EC_ER_WARMSTART_MEMORY_FAILED ) Internal error - warmstart memory device 
[chars] 

Explanation    The process was unable to warmstart the memory device. \ Node was rebooted due to this error.

Recommended Action    If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_FC_ER_MAPPING_STOPPED ) FlashCopy has been stopped [chars] 

Explanation    A Flash Copy mapping task has been stopped because of an error. \ A stopped flash copy may affect the status of other VDisks in the same I/O group. Preparing the stopped flash copies as soon as possible is advised.

Recommended Action    1. Correct higher priority errors. Then, ask the customer to prepare and start the Flash Copy task again. 2. Mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_PREPARE_FAILED 
) FlashCopy prepare failed due to cache flush failure [chars] 

Explanation    A Flash Copy prepare task has failed because a cache flush has failed.

Recommended Action    1. Correct higher priority errors, then retry the prepare tasks. 2. Mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_STOP_COMPLETED 
) Flash Copy Stopped [chars] 

Explanation    The Flash Copy mapping or consistency group has entered the STOPPED state as a result of a user request to stop.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_IC_ER_DIRECTORY_LIST_FAILED ) Failed to obtain directory listing from 
remote node [chars] 

Explanation    An attempt to clean or retrieve files from /dumps directory has failed because of a failure to get listing of the directory from the remote node.

Recommended Action    Determine if the remote node is still online. If not, perform problem determination on the remote node. If it is, retry the command. If it still fails contact the IBM Support Center for assistance. Cisco CLI commands may be used to access the node directly as an alternative.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_IC_ER_FEATURISATION_VIOLATION ) Featurisation violation [chars] 

Explanation    The user has allocated more virtualized storage than licensed for or established a Flash Copy mapping or Remote Copy relationship when these have not been licensed.

Recommended Action    Look in the featurisation log for log entries of type 'Error' to determine the type of violation. The user then should then either reduce virtualized storage, remove the Flash Copy mapping or Remote Copy relationship, so as to be in compliance with their license; or update the license information if that is incorrect; or arrange with their IBM representative to purchase a license for the desired features.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_IC_ER_TRANSFER_FILE_FAILED ) Failed to transfer file from remote node 
[chars] 

Explanation    An attempt to retrieve a file from /dumps directory has failed.

Recommended Action    Determine if the remote node is still online. If not, perform problem determination on the remote node. If it is, retry the command. If it still fails contact the IBM Support Center for assistance. Cisco CLI commands may be used to access the node directly as an alternative.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_IC_EV_IOGRP_NONE_OK 
) Both nodes in the IO group are not available [chars] 

Explanation    Following node remove by the user, there are no nodes left in the IO group.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_IC_EV_UPGRADE_NODE_PENDED ) Software upgrade process failed [chars] 

Explanation    A software upgrade has failed. This might be because of a hardware error or it might be because of a failure in the new version of the software. An automatic software downgrade is performed to restore the nodes to their previous software version. This will be indicated in the log by a 'Software downgrade complete' entry. If the downgrade operation fails to downgrade a node, for example because it is offline, the download operation will stop and wait for the offline SAN Volume Controller to be repaired or deleted from the cluster. While the downgrade operation is in progress, configuration commands sent to the cluster will fail with a message indicating that a software upgrade operation is still in progress. The downgrade operation might take up to three hours.

Recommended Action    1. Display the status of the nodes on the cluster. 2. If any node is offline, delete the offline node from the cluster. If the delete fails with a message indicating that a software upgrade is in progress, this means that the downgrade process is still active. Wait for this operation to either complete or stop on the offline node and then retry the delete. If the downgrade operation had stopped, it will now continue. 3. Solve all logged hardware problems 4. Ask the user to retry the software install. 5. If the installation fails again, report the problem to your software support center. 6. Mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_IC_EV_UPGRADE_PCK_DELIVERY_FAILED ) Software install package cannot be 
delivered to all nodes [chars] 

Explanation    An error occured while sending the software package to the nodes.

Recommended Action    1. Display the status of the nodes on the cluster. 2. If any node is offline, perform problem determination on the node and bring the node back online. Or, alternatively, delete the offline node from the cluster. 3. Retry the software retry the delete. If the downgrade operation had stopped, it will now continue. 3. Solve upgrade command. 4. If the installation fails again, report the problem to your software support center.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_PLIC_LINK ) 
Connection to a configured remote cluster has been lost [chars] 

Explanation    This cluster is no longer able to communicate with the remote copy partner cluster.

Recommended Action    Perform problem determination on the network and the other cluster.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_RC_ER_LSYNC ) Remote 
Copy suffered loss of synchronization [chars] 

Explanation    In a remote-copy operation, the relationship has stopped and lost synchronization, for a reason other than a continuous I/O error.

Recommended Action    1. Correct higher priority errors, then restart the remote copy. 2. Mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_RC_ER_PERS ) Remote 
Copy suffered persistent error [chars] 

Explanation    A Remote Copy relationship has been stopped because of a continuous I/O error.

Recommended Action    1. Correct the higher priority errors, then retry the Remote Copy task. 2. Mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_RC_ER_TIMEOUT ) 
Remote Copy retry timeout [chars] 

Explanation    Remote Copy was unable to find a path to the device in the remote cluster within the timeout period.

Recommended Action    Perform problem determination on the network and remote cluster: Ensure that all nodes in both clusters are configured in the inter-cluster SAN or VSAN. Ensure that all virtual disks in the remote cluster are online.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VG_ER_COPIED_MEDIUM_ERROR ) I/O media error copied [chars] 

Explanation    During a copy or a migrate process a media error was copied to the destination disk.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VG_ER_INSUFFICIENT_VIRTUAL_EXTENTS ) Insufficient extents to create 
Virtual Disk [chars] 

Explanation    There are not enough extents contained within the managed disk group to create the required virtual disk. This error can be logged if a migration is started and then a virtual disk is created which uses the extents that were to be used for the migration.

Recommended Action    Add additional managed disks to the managed disk group or reduce the size of virtual disk to be created.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VG_ER_MIGRATE_STOPPED ) Migration stopped [chars] 

Explanation    The specific migration has been stopped due to errors occurring during migration, these errors have been logged.

Recommended Action    Analyze the error log. Perform problem determination and correct any errors which have occurred. Migrate any specific extents which were not migrated due to the errors.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VG_ER_MIGRATE_SUSPENDED ) Migration suspended [chars] 

Explanation    Migration suspended.

Recommended Action    1. Ensure that all error codes of a higher priority have already been fixed. 2. Ask the customer to ensure that all mdisk groups that are the destination of suspended migrate operations have free extents available. 3. Mark this error as fixed. This will cause the migrate operation to be restarted. If the restart fails a new error will be logged.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_IO_MEDIUM_ERROR ) A media error has occurred during I/O to a Managed 
Disk [chars] 

Explanation    A disk I/O medium error has occurred.

Recommended Action    1. Ask the customer to rewrite the bad data to the block LBA reported in the host systems SCSI sense data. Note: If this error has occurred during a migration, the host system will notice the error until the target device is accessed. 2. Check managed disk status. If all managed disks show a status of online, mark the error you have just repaired as fixed.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_IO_THRESHOLD_WARNING ) Managed Disk error count warning threshold met 
[chars] 

Explanation    IOs to the managed disk have experienced sufficient errors to generate this warning. If the managed disk continues to experience IO errors, the managed disk may be excluded.

Recommended Action    Perform problem determination on the affected managed disk.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_LUN_DISCOVERY_FAILED ) Discovery of LUN failed [chars] 

Explanation    The cluster has a connection to the device on the SAN through this node, but the device has not responded to the node in a manner consistent with a functional device LUN.

Recommended Action    If there are device LUNs that should have been discovered by the node: 1) Perform a manual discovery. 2) Perform problem determination on the device.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_MDISK_PORT_PREFERENCE_IGNORED ) Preferred port is not being used for 
Managed Disk access [chars] 

Explanation    The preferred port designated by the back end controller is not being used for Managed Disk access. A port error or excluded port has prevented the use of the preferred port.

Recommended Action    Perform problem determination on the controller and network to determine the cause of the port error or exclusion.

Error Message     SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_NODERR_CR_FAILED ) 
Cluster recovery failed [chars] 

Explanation    Cluster recovery has failed and a software dump has been created.

Recommended Action    Contact IBM Product support for assistance.

Error Message     SVC-4-SVC_SYSLOG_IF_INTERNAL_WARN: Interface [chars] internal 
warning: [chars] 

Explanation    SVC interface internal warning

Recommended Action    No action is required.

Error Message     SVC-4-SVC_SYSLOG_NPORT_INTERNAL_WARN: [chars] N-port for Interface 
[chars], vsan [dec] internal warning: [chars] 

Explanation    SVC interface internal warning

Recommended Action    No action is required.

SVC-5

Error Message     SVC-5-NODE_NOTICE_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

Error Message     SVC-5-SVC_SYSLOG_IF_CONFIG_DELETED: Interface [chars] configuration 
was deleted[chars] 

Explanation    SVC interface configuration was deleted

Recommended Action    No action is required.

Error Message     SVC-5-SVC_SYSLOG_IF_DOWN: Interface [chars] is down 

Explanation    SVC interface is down

Recommended Action    No action is required.

Error Message     SVC-5-SVC_SYSLOG_IF_UP: Interface [chars] is up 

Explanation    SVC interface is up

Recommended Action    No action is required.

SVC-6

Error Message     SVC-6-NODE_INFO_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_CA_EV_ALL_DATA_UNPINNED 
) All data now unpinned [chars] 

Explanation    All the customer data in the IO group is now unpinned.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_EID_CA_EV_HWS_TO_ASYNCHRONOUS ) Pinned data reduced; cache can operate normally 
[chars] 

Explanation    Enough customer data has been unpinned that the cache is no longer required to operate in write through mode because of the pinned data. (Note that the cache may still operate in write through mode for other reasons.)

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_OK ) Battery 
recharged [chars] 

Explanation    Battery capacity has been restored to above threshold. The node will now come online.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_POWER_DOWN ) 
Poweroff or power failure detected [chars] 

Explanation    The process has received a poweroff or power failure indication. The node is shutting down.

Recommended Action    Restore power. If power was not removed and this occurs: 1. Reload the node. 2. If the error persists, re-install the code on the line card. The node(s) will then have to be removed and re-added back to the cluster. 3. If the error persists, replace the Caching Services Module.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_PWR_BUTTON ) Power 
withdrawn [chars] 

Explanation    Node software was notified that AC power was being shut off or the Caching Services Module was being reset.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_COPY_COMPLETED ) 
Flash Copy Copied [chars] 

Explanation    The Flash Copy mapping or consistency group has entered the IDLE_COPIED state. The target disk now contains a complete copy and is no longer dependent on the source.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_PREPARE_COMPLETED 
) Flash Copy Prepared [chars] 

Explanation    The Flash Copy mapping or consistency group has entered the PREPARED state. It is now possible to Start or Stop the mapping/group.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_EID_IC_EV_CLUSTER_RECOVERY_COMPLETE ) Cluster recovery completed [chars] 

Explanation    Cluster recovery has completed successfully.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_IC_EV_IOGRP_ONE_OK ) One 
node in the IO group is not available [chars] 

Explanation    Following node remove by the user, there is only one node left in the IO group.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_EID_IC_EV_SECURE_DELETE_COMPLETE ) Virtual Disk format completed [chars] 

Explanation    The formatting (writing all zeros) to new extents of the Virtual Disk has completed.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_COLDSTART ) Node 
software started [chars] 

Explanation    The node software has been started (cold start).

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_RC_ER_COPY_COMP ) Remote 
Copy complete [chars] 

Explanation    Background copy complete. The standalone relationship or consistency group has transitioned from 'Inconsistent Copying' to 'Consistent Synchronized'. This will only be logged on the cluster of the Primary Vitrual Disk(s).

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_RC_ER_READY_TO_START ) 
Remote Copy ready to start [chars] 

Explanation    The remote copy relationship or consistency group, whic had been previously been stopped due to an error, is ready to be restarted. All resources are now online.

Recommended Action    Restart the relationship or consistency group.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_VG_EV_MIGRATE_COMPLETE 
) Migration complete [chars] 

Explanation    Migration has completed.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_EID_VL_ER_CLUSTER_FABRIC_VIEW_CHANGE ) Cluster fabric view has been updated. 
[chars] 

Explanation    The node is in the process of discoverying devices on the fabric.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ADD_MAPPING ) 
Virtual Disk to Host SCSI mapping created [chars] 

Explanation    'svctask mkvdiskhostmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ADD_WWPN ) Port 
added to a Host [chars] 

Explanation    'svctask addhostport' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CHANGE_CLUSTER_TIME 
) Attempt to change cluster time (no effect) [chars] 

Explanation    'svctask setclustertime' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CHANGE_TIMEZONE ) 
Attempt to change time zone (no effect) [chars] 

Explanation    'svctask settimezone' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CLUSTER_DISCOVERY ) 
Manual Managed Disk discovery invoked [chars] 

Explanation    'svctask detectmdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CLUSTER_DUMP_CONFIG 
) Cluster config dumped to file [chars] 

Explanation    'svctask dumpconfig' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CLUSTER_MODIFY ) 
Cluster attributes modified [chars] 

Explanation    'svctask chcluster' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CLUSTER_SHUTDOWN ) 
Node or Cluster shutdown [chars] 

Explanation    'svctask stopcluster' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CREATE_FC_MAPPING ) 
Flash Copy mapping created [chars] 

Explanation    'svctask mkfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_CREATE_HOST ) Host 
created [chars] 

Explanation    'svctask mkhost' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_DELETE_FC_MAPPING ) 
Flash Copy mapping deleted [chars] 

Explanation    'svctask rmfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_DELETE_HOST ) Hosts 
deleted [chars] 

Explanation    'svctask rmhost' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_DELETE_MAPPING ) 
Virtual Disk to Host SCSI mapping deleted [chars] 

Explanation    'svctask rmvdiskhostmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_DELETE_PORT_HOST_LIST ) Ports deleted from a Host [chars] 

Explanation    'svctask rmhostport' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_DELETE_WWPN ) Port 
deleted from a Host [chars] 

Explanation    'svctask rmhostport' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_DEVICE_SET_NAME ) 
Controller attributes modified [chars] 

Explanation    'svctask chcontroller' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ERRORLOG_ANALYSE ) 
Error log analyzed [chars] 

Explanation    'svctask finderr' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ERRORLOG_CLEARLOG ) 
Error log cleared [chars] 

Explanation    'svctask clearerrlog' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ERRORLOG_DUMPLOG ) 
Error log dumped [chars] 

Explanation    'svctask dumperrlog' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ERRORLOG_FIX ) Error 
log entry marked fixed [chars] 

Explanation    'svctask cherrstate' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_FC_CONSIST_GRP_SET_NAME ) Flash Copy consistency group name modified 
[chars] 

Explanation    'svctask chfcconsistgrp -name' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_FC_CREATE_CONSIST_GRP ) Flash Copy consistency group created [chars] 

Explanation    'svctask mkfcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_FC_DELETE_CONSIST_GRP ) Flash Copy consistency group deleted [chars] 

Explanation    'svctask rmconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_FC_SET_NAME ) Flash 
Copy mapping name modified [chars] 

Explanation    'svctask chfcmap -name' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_FEATURISATION_CHANGED ) Licensed settings modified [chars] 

Explanation    'svctask chlicense' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_FLASH_PREPARE_CG ) 
Flash Copy consistency group prepared [chars] 

Explanation    'svctask prestartfcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_FLASH_START_CG ) 
Flash Copy consistency group started [chars] 

Explanation    'svctask startfcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_FLASH_STOP_CG ) 
Flash Copy consistency group stopped [chars] 

Explanation    'svctask stopfcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_HOST_DELETE ) Host 
deleted [chars] 

Explanation    'svctask rmhost' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_HOST_SET_NAME ) Host 
attributes modified [chars] 

Explanation    'svctask chhost' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_HWS_SET_NAME ) IO 
Group name modified [chars] 

Explanation    'svctask chiogrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_IO_TRACE_FINISHED ) 
IO Tracing stopped [chars] 

Explanation    'svctask stoptrace' or equivalent GUI/Cisco CLI command has been invoked, or the trigger occurred for a given Managed Disk, automatically stopping the trace.

Recommended Action    Analyse the traces.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_GRP_ADD_MDISK 
) Managed Disk added to Managed Disk group [chars] 

Explanation    'svctask addmdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_GRP_CREATE ) 
Managed Disk Group created [chars] 

Explanation    'svctask mkmdiskgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_GRP_DELETE ) 
Managed Disk Group deleted [chars] 

Explanation    'svctask rmmdiskgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_MDISK_GRP_DELETE_MDISK ) Managed Disk deleted from Managed Disk group 
[chars] 

Explanation    'svctask rmmdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_GRP_SET_NAME 
) Managed Disk Group attributes modified [chars] 

Explanation    'svctask chmdiskgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_SET_NAME ) 
Managed Disk attributes modified [chars] 

Explanation    'svctask chmdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MDISK_UNSLANDER ) 
Managed Disk online [chars] 

Explanation    The managed disk which was excluded is now online.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MIGRATE ) Virtual 
Disk migration to new Managed Disk group started [chars] 

Explanation    'svctask migratevdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_MODIFY_FC_MAPPING ) 
Flash Copy mapping modified [chars] 

Explanation    'svctask chfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_ADD ) Node 
added [chars] 

Explanation    'svctask addnode' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_CREATE_CLUSTER 
) Cluster created [chars] 

Explanation    'cluster add' or equivalent GUI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_DELETE ) Node 
deleted from cluster [chars] 

Explanation    'svctask rmnode' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_PEND ) Node 
Pend [chars] 

Explanation    The node has gone into the pending state. It will shortly go into the online or offline state.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_REMOVE ) Node 
leaving cluster (expected) [chars] 

Explanation    The node has gone offline as expected due to shutdown, upgrade or deletion.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_SET_NAME ) Node 
attributes modified [chars] 

Explanation    'svctask chnode' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_SHUTDOWN ) Node 
shutdown [chars] 

Explanation    'svctask stopcluster -node' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_NODE_UNPEND ) Node 
Unpend [chars] 

Explanation    The node has gone online.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_PLANAR_SN_CHANGE ) 
Attempt to change the Planar Serial Number (no effect) [chars] 

Explanation    'svctask writesernum' command has been invoked. This command has no effect in SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_PRETRIGGER_FC_MAPPING ) Flash Copy mapping prepared [chars] 

Explanation    'svctask prestartfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_QUORUM_CREATE ) 
Quorum disk set [chars] 

Explanation    'svctask setquorum' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_CREATECONSTGRP ) Remote Copy consistency group created [chars] 

Explanation    'svctask mkrcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_CREATEREL ) 
Remote Copy relationship created [chars] 

Explanation    'svctask mkrcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_DELETECONSTGRP ) Remote Copy consistency group deleted [chars] 

Explanation    'svctask rmconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_DELETEREL ) 
Remote Copy relationship deleted [chars] 

Explanation    'svctask rmrcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_REMOTE_MODIFYCONSTGRP ) Remote Copy consistency group modified [chars] 

Explanation    'svctask chrcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_MODIFYREL ) 
Remote Copy relationship modified [chars] 

Explanation    'svctask chrcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_START ) 
Remote Copy relationship started [chars] 

Explanation    'svctask startrcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_START_CG ) 
Remote Copy consistency group started [chars] 

Explanation    'svctask startrcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_STOP ) Remote 
Copy relationship stopped [chars] 

Explanation    'svctask stoprcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_STOP_CG ) 
Remote Copy consistency group stopped [chars] 

Explanation    'svctask stoprcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_SWITCH ) 
Remote Copy relationship switched [chars] 

Explanation    'svctask switchrcrelationship' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_REMOTE_SWITCH_CG ) 
Remote Copy consistency group switched [chars] 

Explanation    'svctask switchrcconsistgrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_SERVICE_APPLY_SOFTWARE ) Software upgrade command accepted [chars] 

Explanation    'cluster upgrade svc-system' or equivalent GUI command has been invoked. The command has been accepted. Additional log entries will track the progress of the upgrade.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_STOP_FC_MAPPING ) 
Flash Copy mapping stopped [chars] 

Explanation    'svctask stopfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_TRIGGER_FC_MAPPING 
) Flash Copy mapping started [chars] 

Explanation    'svctask startfcmap' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_UPGRADE_BACKED_OFF 
) Software downgrade complete [chars] 

Explanation    The software upgrade process failed and all nodes have been restored to the previous level of code.

Recommended Action    Perform problem determination on the cause of the upgrade failure and take corrective action before retrying the upgrade.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_UPGRADE_COMPLETED ) 
Software upgrade complete [chars] 

Explanation    All nodes have successfully moved to the new code level, which will now be committed.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_UPGRADE_STARTED ) 
Software upgrade started [chars] 

Explanation    The software upgrade process has started (the first node is about to be upgraded).

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_CREATE ) 
Virtual Disk created [chars] 

Explanation    'svctask mkvdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_DELETE ) 
Virtual Disk deleted [chars] 

Explanation    'svctask rmvdisk' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_EXPAND ) 
Virtual Disk expanded [chars] 

Explanation    'svctask expandvdisksize' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_VDISK_EXPAND_SINGLE_EXT ) Virtual Disk expanded by single extent 
[chars] 

Explanation    'svctask addvdiskext' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_VDISK_MIGRATE_EXTENT ) Extent migration started [chars] 

Explanation    'svctask migrateexts' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] 
SS_ERR_CFG_VDISK_MIGRATE_EXTENTS ) Extent migration started [chars] 

Explanation    'svctask migrateexts' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_MODIFY_GOVERN 
) Virtual Disk throttling rate modified [chars] 

Explanation    'svctask chvdisk -rate' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_MOVE_HWS ) 
Virtual Disk IO Group changed [chars] 

Explanation    'svctask chvdisk -iogrp' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_SET_NAME ) 
Virtual Disk name modified [chars] 

Explanation    'svctask chvdisk -name' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_ERR_CFG_VDISK_SHRINK ) 
Virtual Disk shrunk [chars] 

Explanation    'svctask shrinkvdisksize' or equivalent GUI/Cisco CLI command has been invoked.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     SVC-6-SVC_SYSLOG_CL_CONFIG: Node [chars] has become config node of 
cluster [chars] 

Explanation    SVC interface has because cluster config node

Recommended Action    No action is required.

Error Message     SVC-6-SVC_SYSLOG_CL_JOIN: Node [chars] has joined cluster [chars] 

Explanation    SVC interface has joined cluster

Recommended Action    No action is required.

Error Message     SVC-6-SVC_SYSLOG_CL_UNJOIN: Node [chars] has left cluster [chars] 

Explanation    SVC interface has left cluster

Recommended Action    No action is required.

Error Message     SVC-6-SVC_SYSLOG_LC_WWN_PURGE: All WWNs for module [dec] have been 
purged[chars] 

Explanation    SVC linecard has purged all WWNs

Recommended Action    No action is required.

Error Message     SVC-6-SVC_SYSLOG_VSAN_INACTIVE: Vsan [dec] suspended 

Explanation    Vsan was suspended; can cause warnings

Recommended Action    No action is required.

SVC-7

Error Message     SVC-7-NODE_DEBUG_MSG: [chars] 

Explanation    Syslog message from a SVC interface node

Recommended Action    No action is required.

SYSMGR Messages

This section contains the SYSMGR messages.

SYSMGR-2

Error Message    SYSMGR-2-BOOTSCOPE_HANDSHAKE: Service [chars] is in the boot scope, 
but tried a regular handshake. Discarding request.

Explanation    A service is trying to take actions that belong to a different class of services.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CFGERASE_ABORTED: Write erase aborted. 

Explanation    Write erase has failed.

Recommended Action    Please verify the other syslog messages printed correct the problem, and try again.

Error Message     SYSMGR-2-CFGSNAPSHOT_ABORTED_DIR: Unable to open the configuration 
directory. Aborting configuration snapshot.

Explanation    The destination location for the snapshot-config could not be found.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGSNAPSHOT_ABORTED_INIT: Unable to initialize the 
configuration directory (error-id [hex]). Aborting configuration snapshot.

Explanation    An attempt to copy the startup-config to snapshot-config has failed because the old data could not be removed.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGSNAPSHOT_ABORTED: Configuration snapshot aborted. 

Explanation    An attempt to save a snapshot of the startup-config has failed.

Recommended Action    Please verify the other syslog messages printed correct the problem, and try again.

Error Message     SYSMGR-2-CFGSYNC_FAILURE: Syncing of the configuration to the standby 
failed. 

Explanation    Syncing of the configuration to the standby failed.

Recommended Action    Please verify the other syslog messages printed correct the problem, and try again.

Error Message     SYSMGR-2-CFGWRITE_ABORTED_DIR: Unable to open the configuration 
directory. Aborting configuration copy.

Explanation    The destination location for the startup-config could not be found.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGWRITE_ABORTED_INIT: Unable to initialize the 
configuration directory (error-id [hex]). Aborting configuration copy.

Explanation    An attempt to copy the running-config to startup-config has failed because the old data could not be removed.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGWRITE_ABORTED_LABEL: Unable to label the new 
configuration (error-id [hex]). Aborting configuration copy.

Explanation    An attempt to copy the running-config to startup-config has failed because the new startup-config could not be stamped.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGWRITE_ABORTED_LOCK: Unable to lock the configuration 
(error-id [hex]). Aborting configuration copy.

Explanation    An attempt to copy the running-config to startup-config has failed because the system could not lock the required configuration items.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CFGWRITE_ABORTED_LOG: Unable to open a log file for the new 
configuration: [chars] (error-id [hex]). Aborting configuration copy.

Explanation    An attempt to copy the running-config to startup-config has failed because a log file could not be created.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CFGWRITE_ABORTED: Configuration copy aborted. 

Explanation    A configuration copy has failed.

Recommended Action    Please verify the other syslog messages printed correct the problem, and try again.

Error Message     SYSMGR-2-CFGWRITE_TIMEOUT_ABORT: Configuration copy aborted by 
timeout. 

Explanation    A service failed to store its configuration in the timeout period. The operation has been aborted.

Recommended Action    No action is required.

Error Message     SYSMGR-2-CFGWRITE_USER_ABORT: Configuration copy aborted by the user. 

Explanation    The user typed CTRL+C while the configuration was being saved, and the operation has been aborted.

Recommended Action    No action is required.

Error Message     SYSMGR-2-CONVERT_FUNC_FAILED: Conversion function failed for service 
[chars] (error-id [hex]). 

Explanation    This message indicates that the conversion function failed for this service.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CONVERT_FUNC_NOTFOUND: Conversion function not found for 
service [chars]. 

Explanation    This message indicates that the system could not find appropriate conversion function for this service.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CONVERT_LIB_NOTFOUND: Conversion library not found for 
service [chars]. 

Explanation    This message indicates that the system could not find conversion library for this service.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CONVERT_STARTUP_ABORTED: Conversion of startup-config 
failed. 

Explanation    This message indicates that the conversion of startup configuration was aborted.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-CONVERT_ZIPPING_FAILED: Failed to zip the converted startup 
configuration. 

Explanation    This message indicates that conversion of the startup configuration failed when system was trying to zip the converted configuration.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-CORE_SAVE_FAILED: [chars]: PID [dec] with message [chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-2-CREATE_DONEFILE_FAILED: Creating /var/run/sysmgr.initdone 
failed with return value: ([dec]).

Explanation    The initialization of the system could not complete.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-DELETE_BINARY_STARTUP_FAILED: Deletion of binary startup 
config failed during boot (error-id [hex]). 

Explanation    This message indicates that the deletion of the binary startup configuration failed during boot.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-FORMAT_FAILURE_SUP_RESET: Failure to format a partition 
successfully causing sup to reset. 

Explanation    The partition used to store non-volatile pss files could not be formatted successfully. The supervisor will be reset.

Recommended Action    If the problem persists, please contact customer support.

Error Message     SYSMGR-2-GSYNC_ABORT: Global sync aborted by signal. 

Explanation    The initial synchronization of the services has been aborted. The synchronization will be attempted again later.

Recommended Action    Use the command 'reload module <mod>' to reset the standby supervisor if you want to try again.

Error Message     SYSMGR-2-GSYNC_GET_TIMEOUT: Request for global sync for UUID [hex] 
not completed in specified time. 

Explanation    Service failed to complete global sync in specified time. The standby will no longer act as a HA standby.

Recommended Action    If the problem persists, please contact customer support.

Error Message     SYSMGR-2-GSYNC_READY_SRVFAILED: Service [chars] on standby supervisor 
failed to restore its snapshot (error-id [hex]). 

Explanation    The initial synchronization of service [chars] has failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service [chars] on active 
supervisor failed to store its snapshot (error-id [hex]). 

Explanation    The initial synchronization of service [chars] has failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-HANDSHAKE_FAILED: Handshake with service [chars] in vdc 
[dec] failed since send failed: [chars] (error-id [hex]). 

Explanation    Handshake with a service failed since system manager could not send handshake response to it.

Recommended Action    No action is required.

Error Message     SYSMGR-2-HAP_FAILURE_SUP_RESET: System reset due to service [chars] 
in vdc [dec] has had a hap failure 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active 
(pre-start phase). 

Explanation    A cold switchover has started (pre-start phase).

Recommended Action    When the other supervisor is back online, use the command 'show system reset-reason' to know what caused the switchover.

Error Message     SYSMGR-2-HASWITCHOVER_START: This supervisor is becoming active. 

Explanation    A cold switchover has started.

Recommended Action    When the other supervisor is back online, use the command 'show system reset-reason' to know what caused the switchover.

Error Message     SYSMGR-2-HEARTBEAT_FAILED: Sysmgr heartbeat failed at %lu. [chars]. 
[chars] ([dec]) 

Explanation    System manager had failure while trying to heartbeat with KLM

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-INBAND_START_FAILED: Failure while bringing up inband after 
ISSU reboot, errno: [dec]. 

Explanation    Sysmgr tried to bring up inband after ISSU reboot, but the call returned error.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-INVALID_HANDSHAKE: Invalid secret ([dec]) received from 
service [chars]. Expected [dec].

Explanation    A service can't be started.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-INVALID_SYSMGRCONF: [chars]: invalid configuration file 
[chars]: [chars] (error-id [hex]). 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-INVALID_VERSIONMSG: The remote System Manager ([chars]) 
declares itself in the same state as this System Manager ([chars]).

Explanation    The redundancy state negotiation between the two supervisors failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-ISSU_FAILED: The ISSU has failed: [chars] (error-id [hex]) 

Explanation    The ISSU has failed and the switch need to be rebooted.

Recommended Action    No action is required.

Error Message     SYSMGR-2-LAST_CORE_BASIC_TRACE: [chars]: PID [dec] with message 
[chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-2-MSG_SEND_FAILURE_STANDBY_RESET: Failure in sending message 
to standby causing standby to reset. 

Explanation    We will be resetting the standby since mts on the active is unable to send a message to standby.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-MTS_FLUSH_SYNC_QUEUE_FAILURE: flush mts sync queue failed 
with [chars] (errno [dec]) 

Explanation    Calling mts_flush_sync_queue to guarante no outstanding messages. the failure might affect HA

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-NON_VOLATILE_DB_FULL: System non-volatile storage usage is 
unexpectedly high at [dec]%. 

Explanation    System non-volatile storage space is almost full.

Recommended Action    Please run the command 'clear processes log pid <pid>' to delete log file for specific instance that show up via the command 'show processes log all'. To clear out all log files, use the command 'clear processes log all'

Error Message     SYSMGR-2-ONBOARD_FAILURE_LOGGING_FULL: Onboard failure logging usage 
is unexpectedly high at [dec]%. 

Explanation    Onboard failure logging space is almost full.

Recommended Action    Please run the command 'clear logging onboard'. If this message continues to persist, please contact TAC.

Error Message     SYSMGR-2-PARSEERR_DEPENDCYCLE: Dependency cycle found among [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDCONFIG: [chars]: duplicated definition 
for service config. Previous definition in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDDEPEND: [chars]: duplicated dependency 
from [chars] for service [chars]. Previous use in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDNAME: [chars]: short name [chars] used by 
service [chars] is also used by service [chars] in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDOPTION: [chars]: duplicated definition 
for option [chars]->[chars] (service [chars]). Previous definition in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDSERVICE: [chars]: duplicated definition 
for service [chars]. Previous definition in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUPLICATEDVERDB: [chars]: duplicated definition for 
service version_db. Previous definition in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_DUP_UGRPENTRY: [chars]: service [chars] duplicated 
in the current upgrade group. Previous use in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INCONSISTENTOPT: [chars]: option [chars]=[chars] 
not consistent with [chars]=[chars] for service [chars] 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDCOMPCONDDEPEND: [chars] (in dependency list 
of compulsory conditional service [chars]): optional conditional service [chars] 
not allowed.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDCONDDEPEND: [chars] (in dependency list of 
ASAP service [chars]): conditional service [chars] not allowed.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDDEPEND: [chars] (in dependency list of 
service [chars]): service [chars] not defined for scope [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDEXEC: [chars]: invalid executable [chars] 
for service [chars]: [chars] ([dec]).

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDHANDSHAKEDEPEND: [chars] (in handshake 
dependency list of service [chars]): service [chars] is MTS unaware or not defined 
for scope [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDIDENT: [chars]: [chars] [chars] not found 
for service [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDOPTION: [chars]: option [chars]->[chars] 
cannot be set to [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDSTDBYDEPEND: [chars]: service [chars] cannot 
be dependent on service [chars] due to the standby mode wait for that service.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALIDVDCDEPEND: [chars] (in dependency list of 
service [chars]): service [chars] is a [chars] service.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_CLEANUP_ARGUMENTS: [chars]: 
cleanup_arguments = [chars]: only conditional services that are scripts can 
specify cleanup arguments 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_COND_SRV_MODE: [chars]: service [chars] not 
defined for scope control or not mts aware.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_DIR: [chars]: [chars] is not a valid 
[chars]: [chars] ([dec]). 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_GLOBAL_SYNC: [chars]: mts unaware service 
may not request for a global sync. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_HB: [chars]: [dec] is not a valid heartbeat 
timeout. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_MAX_INSTANCE: [chars]: [dec] is not a valid 
max_instance. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_SHELLTREE: [chars]: invalid shell parser 
tree [chars] for service [chars]: [chars] ([dec]).

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_STANDBY_MODE_GLOBAL_SYNC: [chars]: service 
with standby mode wait cannot request for a global sync.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_STANDBY_MODE: [chars]: standby_mode should 
be run. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_TRANSL: [chars]: invalid translator [chars] 
for service [chars]: [chars] ([dec]).

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_INVALID_UGRPENTRY: [chars]: service [chars] is not 
defined. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_MISSINGOPTION: [chars]: option [chars]->[chars] 
missing from service definition for service [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_MTSUNAWARE_HANDSHAKEDEPEND: [chars]: service 
[chars] is MTS unaware and cannot have handshake dependencies.

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_NORESTART: [chars]: option [chars]->[chars] cannot 
be set without setting option [chars]->[chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_NOTCONFIG: [chars]: [chars] implemented only for 
service config. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_REPARSE_CANNOT_ADD_SRV: Service [chars] cannot be 
added 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_REPARSE_CANNOT_DELETE_SRV: Service [chars] cannot 
be removed 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_REPARSE_CANNOT_MODIFY_PARAM: Cannot modify 
parameter [chars] for the service [chars], old value = [chars], new value = [chars] 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_REPARSE_CANNOT_MODIFY_SRV: Configuration for 
service [chars] cannot be modified, param modified = [chars], old_value = [chars], 
new_value = [chars] 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_REP_UGRPENTRY: [chars]: service [chars] is used in 
more than one upgrade group. First use in [chars].

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_TOOMANYDEPENDS_MULTIPLE_INST: [chars]: too many 
multiple instance dependencies ([dec]) for service [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_TOOMANYDEPENDS: [chars]: too many dependencies 
([dec]) for service [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_UGRPDUPLICATEDNAME: [chars]: upgrade group name 
[chars] already used in [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARSEERR_UGRPNAMEREDEFINED: [chars]: the upgrade group is 
already called [chars]. 

Explanation    The system image contains an inconsistent list of services. The initialization of the system can't proceed further.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PARTIAL_CFGWRITE_ABORTED: Partial configuration copy 
aborted. 

Explanation    A partial configuration copy has failed.

Recommended Action    Please verify the other syslog messages printed correct the problem, and try again. If problem persists, please run the command 'copy running-config startup-config' and try again.

Error Message     SYSMGR-2-PLUGIN_BOOTUP_FAILURE: The bootup of the supervisor has 
failed due to plugin load: [chars] (error-id [hex])

Explanation    The bootup of the supervisor has failed due to plugin load.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PSS2FILE_CONVERT_FAILED: Conversion of file [chars] failed. 

Explanation    Conversion of internal data format failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-PSS2_VOLATILE_DB_FULL: Volatile database usage in kernel is 
unexpectedly high at [dec]%. 

Explanation    System volatile database in kernel space is almost full.

Recommended Action    Please run the command 'system system internal pss kernel memstats'. If this message continues to persist, please contact TAC.

Error Message     SYSMGR-2-REDSTATE_GETFAILED: Failed to request redundancy state: 
[chars] (error-id [hex]). 

Explanation    The local supervisor is unable to get the redundancy state.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-REDSTATE_SETFAILED: Failed to set redundancy state: ret_val 
([dec]). 

Explanation    The local supervisor is unable to get the redundancy state.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-REDUNDANCY_CHANNEL_FAILURE: Remote sup will be rebooted 
since its coming up as active when local sup is still active. 

Explanation    Remote sup is becoming active although local sup is still active. As a result, local sup will cause the remote sup to reset itself.

Recommended Action    If the problem persists, please contact customer support.

Error Message     SYSMGR-2-REDUNDANCY_HEARTBEAT_FAILURE: Heartbeat between active and 
standby on the redundancy channel not working for last [dec] minutes. 

Explanation    This supervisor is not receiving heartbeat on the redundancy channel from the other supervisor. This can result in problems during switchover and switchover may even fail.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-RESTART_SYSTEM_LOG: We will be restarting system soon for 
vdc [dec]. 

Explanation    We will be restarting system since we were trying to do a hot switchover before all the state could have been transferred to this supervisor. So we will be doing a cold switchover now.

Recommended Action    No action is required.

Error Message     SYSMGR-2-RESTORE_RUNTIME_DB_FAILED: Restoring of runtime database for 
fabric switch upgrade failed during boot (error-id [hex]).

Explanation    This message indicates that the runtime database could not be restored during boot for the fabric switch upgrade.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SAVE_RUNTIME_DB_FAILED: Saving of runtime database for 
fabric switch upgrade failed (error-id [hex]).

Explanation    This message indicates that the runtime database could not be saved for the fabric switch upgrade.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SERVICE_CRASHED: Service [chars] (PID [dec]) hasn't caught 
signal [dec][chars] 

Explanation    A service has terminated its execution abnormally. The service might be restarted, depending on the HA policies implemented for the service.

Recommended Action    Please use the command 'show process' to verify that the service has been restarted.

Error Message     SYSMGR-2-SHUTDOWN_FAILURE: Unable to set signal handler for graceful 
shutdown: [chars] (error-id [hex]).

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-2-SHUTDOWN_REJECT: The System Manager is busy saving the 
configuration. Please try again later.

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-2-SHUTDOWN_SYSTEM_LOG: vdc [dec] will shut down soon. 

Explanation    We are shutting down system the vdc

Recommended Action    No action is required.

Error Message     SYSMGR-2-SIGKILL_FAILURE: Service [chars] failure to respond to 
SIGKILL causing supervisor to reset. Last heartbeat %.2f secs ago. 

Explanation    We will be resetting the supervisor since service failed to respond to SIGKILL sent to it by System Manager.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SOCKET_ERROR: Failed to open socket connection, errno: 
[dec]. 

Explanation    Call to open socket connection failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SRV_CLEAR_MEMORY_ALERT: service [chars] clear memory alert 
([dec]%) 

Explanation    Clean Memory Alert Event received

Recommended Action    No action is required.

Error Message     SYSMGR-2-SRV_MAJOR_MEMORY_ALERT: service [chars] major memory alert 
([dec]%) 

Explanation    Major Memory Alert Event received

Recommended Action    No action is required.

Error Message     SYSMGR-2-SRV_MINOR_MEMORY_ALERT: service [chars] minor memory alert 
([dec]%) 

Explanation    Minor Memory Alert Event received

Recommended Action    No action is required.

Error Message     SYSMGR-2-SRV_SPAWN_FAILED: Spawning of service [chars] in vdc [dec] 
failed : [chars] (error-id [hex]). 

Explanation    Failed to spawn a service

Recommended Action    No action is required.

Error Message     SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up. 

Explanation    This message is printed if the standby supervisor doesn't complete its boot procedure (i.e. it doesn't reach the login prompt on the local console) 3 to 6 minutes after the loader has been loaded by the BIOS. This message is usually caused by boot variables not properly set for the standby supervisor. This message can also be caused by a user intentionally interrupting the boot procedure at the loader prompt (by means of pressing ESC).

Recommended Action    Connect to the local console of the standby supervisor. If the supervisor is at the loader prompt, try to use the 'boot' command to continue the boot procedure. Otherwise, issue a 'reload' command for the standby supervisor from a vsh session on the active supervisor, specifying the 'force-dnld' option. Once the standby is online, fix the problem by setting the boot variables appropriately.

Error Message     SYSMGR-2-STARTUP_CONVERSION_FAILED: Startup config conversion failed 
during boot (error-id [hex]). 

Explanation    This message indicates that the conversion of startup configuration failed during boot.

Recommended Action    If the problem persists, please use the vshboot command 'init system' to initialize the configuration partition.

Error Message     SYSMGR-2-START_SCRIPT_FAILED: Start script (/isan/etc/rc.sysmgr 
start) failed with return value: ([dec]).

Explanation    The initialization of the system could not complete.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SUBPROC_SPAWN_FAILED: Spawning of sub-process [chars] in vdc 
[dec] failed : [chars] (error-id [hex]). 

Explanation    Failed to spawn a sub-process

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_OVER: Switchover completed. 

Explanation    The switchover is completed.

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_SRVCRASHED: Service [chars] (PID [dec]) crashed 
during switchover - hasn't caught signal [dec] . 

Explanation    The switchover failed because a service crashed during switchover.

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_SRVFAILED: Service [chars] failed in performing 
its switchover actions (error-id [hex]). 

Explanation    The switchover failed because a service could not transition to the active state.

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_SRVTERMINATED: Service [chars] (PID [dec]) 
terminated during switchover with error code [dec] . 

Explanation    The switchover failed because a service terminated during switchover.

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_THRESHOLD_EXCEEDED: Switchover threshold 
exceeded ([dec] switchovers happened within [dec] seconds). Powering down all 
linecards. 

Explanation    Switchover threshold exceeded

Recommended Action    No action is required.

Error Message     SYSMGR-2-SWITCHOVER_TIMEOUT: Service [chars] (vdc [dec]) did not 
respond to switchover message in [dec] seconds 

Explanation    The switchover timeout because a service failed to response

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SYNC_FAILURE_MSG_PAYLOAD: vdc [dec]: [chars] 

Explanation    Dump out the msg to know what causes sync failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-SYNC_FAILURE_STANDBY_RESET: Failure in syncing messages to 
standby for vdc [dec] causing standby to reset. 

Explanation    We will be resetting the standby since mts on the active is unable to sync messages to standby.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is 
unexpectedly high at [dec]%. 

Explanation    System /tmp space is almost full.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-UNEXPECTED_GSYNC_RESTART_STANDBY: Sending a message to 
restart system on standby on vdc [dec]. 

Explanation    Activity occurred on active supervisor that is incompatible with state of standby. System will be restarted on standby.

Recommended Action    No action is required.

Error Message     SYSMGR-2-VDC_CREATE_DELETE_SRVCRASHED: Global vdc-aware service 
[chars] (PID [dec]) crashed during vdc create/delete on standby - hasn't caught 
signal [dec] . 

Explanation    The creation/deletion of vdc on standby failed because a global vdc-aware service crashed on standby.

Recommended Action    No action is required.

Error Message     SYSMGR-2-VDC_CREATE_DELETE_SRVTERMINATED: Global vdc-aware service 
[chars] (PID [dec]) terminated during vdc create/delete on standby with error code 
[dec] .

Explanation    The creation/deletion of vdc on standby failed because a global vdc-aware service terminated on standby.

Recommended Action    No action is required.

Error Message     SYSMGR-2-VDC_DELETE_FAILURE: The vdc delete has failed: [chars] 
(error-id [hex])

Explanation    The vdc delete has failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-2-VDC_NOT_CLEANEDUP_SRVS: vdc [dec]: [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is 
unexpectedly high at [dec]%. 

Explanation    System volatile database space is almost full.

Recommended Action    Please run the command 'system pss shrink'. If this message continues to persist, please contact TAC.

Error Message     SYSMGR-2-WARMSWITCHOVER_START: This supervisor is becoming active. 

Explanation    A cold switchover has started.

Recommended Action    When the other supervisor is back online, use the command 'show system reset-reason' to know what caused the switchover.

Error Message     SYSMGR-2-WDT_KGDB: System watchdog kgdb has been [chars] for slot 
[dec]. 

Explanation    System watchdog kgdb has been [chars]. If the command has been enabled, the system will go into kgdb if there is a watchdog timeout.

Recommended Action    No action is required.

SYSMGR-3

Error Message     SYSMGR-3-BASIC_TRACE: [chars]: PID [dec] with message [chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CAPABILITY_REDUN_CHANGE: Redundancy mode changed to [chars] 
due to configuration change. 

Explanation    Some configuration changes have occurred causing administrative redundancy mode to change.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CFGCTRL_ABORT: signal to abort cfgctrl as super changes to 
the unstable state 

Explanation    When super state changes to unstable, cfgctrl should be terminated

Recommended Action    No action is required.

Error Message     SYSMGR-3-CFGERASE_FAILED: Configuration erase failed (error-id 
[hex]). 

Explanation    The requested configuration erase has failed. [dec] is the error-ID representing the failure reason.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CFGSNAPSHOT_FAILED: Configuration snapshot failed (error-id 
[hex]). 

Explanation    The requested configuration snapshot has failed. [dec] is the error-id representing the failure reason.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CFGWRITE_FAILED: Configuration copy failed (error-id [hex]). 

Explanation    The requested configuration copy has failed. [dec] is the error-id representing the failure reason.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CFGWRITE_REJECT: Discarding request for configuration 
[chars]: configuration action already in progress.

Explanation    Another instance of the command 'copy running-config startup-config' is in progress.

Recommended Action    Please wait for the other instance to complete.

Error Message     SYSMGR-3-CFGWRITE_SRVCRASHED: Service [chars] crashed with signal 
([dec]) while configuration was being saved

Explanation    A required service has crashed while configuration was being saved. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-CFGWRITE_SRVFAILED: Service [chars] failed to store its 
configuration (error-id [hex]). 

Explanation    A required service has failed to store its own configuration into the startup-config. The overall configuration copy is considered failed.

Recommended Action    Use the 'show process' command to verify that the system is running properly and the service [chars] is behaving correctly. Then try again.

Error Message     SYSMGR-3-CFGWRITE_SRVTERMINATED: Service [chars] terminated with 
error code ([dec]) while configuration was being saved

Explanation    A required service has terminated while configuration was being saved. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-CFGWRITE_SRVTIMEOUT: Service [chars] failed to store its 
configuration in the timeout period

Explanation    A required service has failed to send a response after receving a request to store its configuration into the startup-config. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-CFGWRITE_VDCSRVCRASHED: Service [chars] in vdc [dec] crashed 
with signal ([dec]) while configuration was being saved

Explanation    A required service has crashed while configuration was being saved. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-CFGWRITE_VDCSRVFAILED: Service [chars] in vdc [dec] failed 
to store its configuration (error-id [hex]). 

Explanation    A required service has failed to store its own configuration into the startup-config. The overall configuration copy is considered failed.

Recommended Action    Use the 'show process' command to verify that the system is running properly and the service [chars] is behaving correctly. Then try again.

Error Message     SYSMGR-3-CFGWRITE_VDCSRVTERMINATED: Service [chars] in vdc [dec] 
terminated with error code ([dec]) while configuration was being saved

Explanation    A required service has terminated while configuration was being saved. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-CFGWRITE_VDCSRVTIMEOUT: Service [chars] in vdc [dec] failed 
to store its configuration in the timeout period

Explanation    A required service has failed to send a response after receving a request to store its configuration into the startup-config. The overall configuration copy is considered failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-COPY_CORES_FAILED: Copying cores failed ([dec]). 

Explanation    Copying cores to the destination failed because of an error specified in the log.

Recommended Action    No action is required.

Error Message     SYSMGR-3-COREDUMP_TIMEOUT: Failed to store the core in the specified 
time. Resetting .... 

Explanation    Failed to store the core in the specified time. Resetting ...

Recommended Action    No action is required.

Error Message     SYSMGR-3-CORE_CLIENT_INIT_FAILED: Core client will not be started due 
to some internal error. 

Explanation    Core client will not be started due to some internal error.

Recommended Action    No action is required.

Error Message     SYSMGR-3-CORE_OP_FAILED: Core operation failed: [chars] 

Explanation    Mainly use to display failure on core operation in general

Recommended Action    No action is required.

Error Message     SYSMGR-3-CORE_SERVER_INIT_FAILED: Core server will not be started due 
to some internal error. 

Explanation    Core server will not be started due to some internal error.

Recommended Action    No action is required.

Error Message     SYSMGR-3-DAEMONIZE_FAILED: Unable to daemonize service [chars]: 
[chars] ([dec]). 

Explanation    A service could not be spawned.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-FAILED_PFM_HANDSHAKE: PFM-handshake from service [chars] 
failed (error-id [hex]). 

Explanation    The Platform Manager handshake has failed. The system can't proceed with the initialization.

Recommended Action    No action is required.

Error Message     SYSMGR-3-GSYNC_TIMEOUT_FAILED: Failed to set timeout for global sync 
for an application ([dec]). 

Explanation    Failed to set timeout for global sync for an application. This can result in global sync to be stuck forever if application never complete global sync.

Recommended Action    No action is required.

Error Message     SYSMGR-3-HEARTBEAT_FAILURE: Service [chars] sent SIGABRT for not 
setting heartbeat for last [dec] periods. Last heartbeat %.2f secs ago. 

Explanation    A service is not setting proper heartbeats to System Manager So it will kill this service and if this service has restartability set to TRUE, the service will restart.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-INVALID_BOOT_HANDSHAKE: Boot-scope-handshake received from 
service [chars], that is in scope [dec] (not the boot scope).

Explanation    A service is trying to take actions that belong to a different class of services.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-INVALID_GSYNC_GET: Service [chars] vdc [dec] requesting 
gsync without setting proper flag in its conf file. 

Explanation    Service is requesting global sync without setting proper flag in its conf file.

Recommended Action    No action is required.

Error Message     SYSMGR-3-INVALID_PFM_HANDSHAKE: PFM-handshake received from service 
[chars], that is in scope [dec] (not the boot scope).

Explanation    A service is trying to take actions that belong to the Platform Manager service.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-INVALID_TRANSITION: Transition from state [chars] to state 
[chars] is not allowed. 

Explanation    Unexpected transition in the System Manager state machine.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-INVALID_UUID: Service [chars] is configured with UUID [hex], 
but uses UUID [hex].

Explanation    The identity of a service is inconsistent in the image file

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-ISSU_BEGIN_FAILED: ISSU cannot proceed (error-id [hex]). 

Explanation    This message indicates that some service has blocked the ISSU.

Recommended Action    No action is required.

Error Message     SYSMGR-3-LC_IMAGE_UPGRADE_FAILURE: Linecard image upgrade request 
failed(error-id [hex]). 

Explanation    Linecard image upgrade request failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-LC_RESET: Resetting linecard 

Explanation    Linecard is being reset

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-LC_SAVE_STATES_FAILURE: Save states request for the linecard 
failed(error-id [hex]). 

Explanation    Save state request for the linecard failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-LC_START_ASYNC_FAILURE: Start async notification request 
failed(error-id [hex]). 

Explanation    Start async notification request for the linecard failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-LC_STOP_ASYNC_FAILURE: Stop async notification request 
failed(error-id [hex]). 

Explanation    Stop async notification request for the linecard failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-LC_UPG_ERROR: LC ERROR: [chars] 

Explanation    Linecard upgrade error message

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-MISSING_OPTIONAL_CAPABILITY: Incomplete support for the 
current running-config on standby supervisor. 

Explanation    Loose config incompatibilities exist between active and standby sup. Operational redundancy mode is still set to HA.

Recommended Action    No action is required.

Error Message     SYSMGR-3-MODULE_LOCK_FAILED: Failed to lock the local module to avoid 
reset (error-id [hex]). 

Explanation    Locking the local module has failed. Reloading the local module can now result in switchover to fail.

Recommended Action    No action is required.

Error Message     SYSMGR-3-ND_UPGD_RECOVERY_SRVFAILED: Service [chars] in vdc [dec] 
failed in non-disruptive upgrade recovery (error-id [hex]). 

Explanation    The non-disruptive upgrade failed because a service could not recover its state.

Recommended Action    No action is required.

Error Message     SYSMGR-3-OPERATIONAL_MODE_WARM: Operational redundancy mode set to 
warm (error-id [hex]). 

Explanation    Operational redundancy mode will be set to warm. [dec] is the error-ID representing the reason.

Recommended Action    No action is required.

Error Message     SYSMGR-3-PARTIAL_CFGWRITE_FAILED: Partial configuration copy failed 
(error-id [hex]). 

Explanation    The requested configuration copy has failed. [dec] is the error-ID representing the failure reason.

Recommended Action    No action is required.

Error Message     SYSMGR-3-PARTIAL_CFGWRITE_VER_MISMATCH: Startup-config version not 
same as current software version. 

Explanation    Startup-config version not same as current software version.

Recommended Action    Please do a copy running startup, and try again.

Error Message     SYSMGR-3-RTDBCTRL_SRVFAILURE: Service [chars] responded with a 
failure 

Explanation    A service responded with a failure to the request

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-RTDBCTRL_SRVTIMEOUT: Service [chars] failed to respond back 
to System Manager in the specified timeout period

Explanation    A required service has failed to send a response after receiving a request for the fabric switch upgrade.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-SERVICE_TERMINATED: Service [chars] (PID [dec]) has finished 
with error code [chars] ([dec]).

Explanation    A service has terminated its execution normally. Depending on the value of [dec2] and the HA policies implemented for the service, the service might be restarted automatically.

Recommended Action    No action is required.

Error Message     SYSMGR-3-SHUTDOWN_OVER: The System Manager is shutting down now. 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-3-SHUTDOWN_START: The System Manager has started the shutdown 
procedure. 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-3-STANDBY_VDC_RESTART_FAILURE: vdc [dec] on standby failed to 
restart. error: [chars] ([hex]) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-3-SYSMGR_CRASHED: Sysmgr (PID [dec]) [chars] 

Explanation    Sysmgr has terminated abnormally.

Recommended Action    Please use the command 'show process' to verify that sysmgr has been restarted.

Error Message     SYSMGR-3-TFTP_CORES_FAILED: TFTPing cores failed ([chars]). 

Explanation    TFTPing cores to the destination failed because of an error specified in the log.

Recommended Action    No action is required.

Error Message     SYSMGR-3-UNACCEPTABLE_WAIT: Service [chars], no response from System 
Manager after [dec] seconds. Terminating.

Explanation    A spawned service couldn't handshake with the System Manager and it's about to be terminated.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-3-UNLINK_RELINK_CONF_FILES_FAILED: [chars] of conf files 
failed. plugin_id [dec] 

Explanation    Unlink and/or Relink of configuration files failed.

Recommended Action    No action is required.

Error Message     SYSMGR-3-URIFS_APPLY_FAILED: Applying URI filesystem database failed 
(error-id [hex]). 

Explanation    The application of URI filesystem database has failed. [dec] is the error-ID representing the failure reason.

Recommended Action    No action is required.

SYSMGR-4

Error Message     SYSMGR-4-CFGWRITE_PARTIALFORCED: Some services are missing; partial 
configuration write forced.

Explanation    The system is not fully operational, but a configuration copy has been forced. The services that are not running won't save their configuration, and the next time they will restart with a default configuration.

Recommended Action    Use the 'show process' command to find out which required services are not running.

Error Message     SYSMGR-4-ON_DEMAND_STOP_UID_KNOWN: On-demand service [chars] stopped 
by uid ([dec]). 

Explanation    The service start type is specified as type on-demand in its configuration file and an external request requested to abort it.

Recommended Action    No action is required.

Error Message     SYSMGR-4-ON_DEMAND_STOP: On-demand service [chars] stopped. 

Explanation    The service start type is specified as type on-demand in its configuration file and an external request requested to abort it.

Recommended Action    No action is required.

Error Message     SYSMGR-4-PARSEWARN_INVALID_CFGFILE: [chars]: unable to find [chars]: 
[chars] ([dec]). 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-4-PARSEWARN_RESTART_CNT_TOO_BIG: Service [chars]: [chars] 
restart count of [dec] too big, needs to be set to [dec]. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-4-PARSEWARN_VALUE_TOO_SMALL: [chars]: [chars] is too small, 
replaced with [dec]. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-4-READCONF_REJECT: Discarding configuration update request: 
[chars]. 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-4-READCONF_STARTED: Configuration update started (PID [dec]). 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-4-SRVSCOPE_DELAYED: Waiting for redundancy state; termination 
delayed for scope [chars].

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-4-UGRP_ALL_COMPLETED: Upgrade completed for all the groups. 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

SYSMGR-5

Error Message     SYSMGR-5-CFGERASE_DONE: Configuration erase successful. 

Explanation    The requested configuration erase has completed successfully.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGERASE_STARTED: Configuration erase started (PID [dec]). 

Explanation    The requested configuration erase has started. [dec] is the Process-ID of the process servicing the request.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGINIT_STARTED: Initialization of the startup configuration 
started (PID [dec]). 

Explanation    The requested initialization of the startup configuration has started. [dec] is the Process-ID of the process servicing the request.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGSNAPSHOT_DONE: Configuration snapshot successful. 

Explanation    The requested configuration snapshot has completed successfully.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGSNAPSHOT_STARTED: Configuration snapshot started (PID 
[dec]). 

Explanation    The requested configuration snapshot has started. [dec] is the Process-ID of the process servicing the request.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGWRITE_DONE: Configuration copy successful. 

Explanation    The requested configuration copy has completed successfully.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CFGWRITE_STARTED: Configuration copy started (PID [dec]). 

Explanation    On the active supervisor, this message indicates that the system has started to service a 'copy running-config startup-config' requested by the user. On the standby supervisor, this message indicates that the system is synchronizing the startup-config from the active supervisor. [dec] is the Process-ID of the process servicing the request.

Recommended Action    No action is required.

Error Message     SYSMGR-5-CONVERT_STARTUP_STARTED: Configuration conversion started 
(PID [dec]). 

Explanation    This message indicates that the system has started conversion of startup configuration. This happens either on system boot or during the course of an upgrade.

Recommended Action    No action is required.

Error Message     SYSMGR-5-DELETE_BINARY_STARTUP_STARTED: Deletion of binary startup 
configuration started (PID [dec]). 

Explanation    This message indicates that the system will be deleting the binary startup configuration, due to an error in the conversion of the startup conversion.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-5-FSM_STATE_TRANS: System Manager NESTED state transition from 
[chars] to [chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-5-HEARTBEAT_LOSS: Service [chars] heartbeat loss [dec] ,max 
[dec] . 

Explanation    Log to indicate loss of HeartBeat from a service.

Recommended Action    No action is required.

Error Message     SYSMGR-5-IMPROPER_CLEANUP: Service [chars] exited without replying to 
switchover request. 

Explanation    A conditional service exited without replying to switchover request. This message is for logging purposes only and does not affect the functionality of the system

Recommended Action    No action is required.

Error Message     SYSMGR-5-ISSU_ABORT: Notifying services of aborted ISSU (PID [dec]).

Explanation    This message indicates that the ISSU has been aborted and the services have been asked to rollback any changes.

Recommended Action    No action is required.

Error Message     SYSMGR-5-ISSU_BEGIN_STARTED: Notifying services of ISSU (PID [dec]).

Explanation    This message indicates that the system has started notifying services for the ISSU. Services can block the upgrade at this point.

Recommended Action    No action is required.

Error Message     SYSMGR-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade 

Explanation    Linecard is being rebooted as a part of upgrade

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-5-LC_UPGRADE_START: Starting linecard upgrade 

Explanation    Linecard upgrade is starting

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-5-MODULE_ONLINE: System Manager has received notification of 
local module becoming online. 

Explanation    System Manager has received notification of local module becoming online.

Recommended Action    No action is required.

Error Message     SYSMGR-5-PARTIAL_CFGWRITE_ASCII_CONFIG: Startup-config version not 
present. 

Explanation    Startup-config version not present.

Recommended Action    Startup-config version is not present. Ascii configuration will be applied.

Error Message     SYSMGR-5-PARTIAL_CFGWRITE_DONE: Partial configuration copy 
successful. 

Explanation    The requested configuration copy has completed successfully.

Recommended Action    No action is required.

Error Message     SYSMGR-5-PARTIAL_CFGWRITE_STARTED: Partial configuration copy started 
by UUID [hex] (PID [dec]). 

Explanation    This message is printed only on active supervisor, and indicates that service with mentioned UUID has requested a partial write mem. [dec] is the Process-ID of the process servicing the request.

Recommended Action    No action is required.

Error Message     SYSMGR-5-RECOVERY_FAILED: Stateful recovery failed, system manager 
will now start stateless. 

Explanation    Stateful recovery failed, system manager will now restart system and start stateless.

Recommended Action    No action is required.

Error Message     SYSMGR-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller 
started (PID [dec]). 

Explanation    This message indicates that the system has started the restoration of the runtime database. This happens during the non-disruptive fabric switch upgrade.

Recommended Action    No action is required.

Error Message     SYSMGR-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully 
restored. 

Explanation    This message indicates that the runtime database has been successfully restored for the non-disruptive fabric switch upgrade.

Recommended Action    No action is required.

Error Message     SYSMGR-5-RUNTIME_DB_SAVE_STARTED: Runtime database save has started 
(PID [dec]). 

Explanation    This message indicates that the system has started the saving of the runtime database. This happens during the non-disruptive fabric switch upgrade.

Recommended Action    No action is required.

Error Message     SYSMGR-5-SERVICE_DELETED: Service [chars] has been removed from the 
System Manager database.

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

Error Message     SYSMGR-5-STATEFUL_STATE: System Manager is in state [chars] after 
stateful restart. 

Explanation    System Manager has been restarted stateful after an error that resulted in System Manager exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-5-SUBPROC_KILLED: [chars] (PID [dec]) hasn't caught signal 
[dec][chars] 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-5-SUBPROC_TERMINATED: [chars] (PID [dec]) has finished with 
error code [chars] ([dec]). 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-5-UGRP_COMPLETED: Upgrade completed for group [dec]. 

Explanation    This is a legacy message that can be ignored from Cisco MDS SAN-OS release 1.3(4a).

Recommended Action    No action is required.

SYSMGR-6

Error Message     SYSMGR-6-ALL_SCOPES_STARTED: System services have completely started 
at this time. 

Explanation    System services have completely started at this time.

Recommended Action    No action is required.

Error Message     SYSMGR-6-HANDSHAKE_DONE: Handshake with service [chars] successfully 
performed. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-6-HANDSHAKE_VERIFYING_DONE: Handshake verification done from 
service [chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-6-LC_UPG_DEBUG: LC DEBUG: [chars] 

Explanation    Linecard upgrade debug message

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     SYSMGR-6-RLIMIT_INFO: rlimit of service [chars]([dec]) = %llu 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SERVICE_STARTED: Service [chars] in vdc [dec] started with 
PID([dec]). 

Explanation    The System Manager is starting a service. This message is for debugging purposes only.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SERVICE_SUCCESS_EXIT: Service [chars] (PID [dec]) has 
successfully exited with exit code [chars] ([dec]).

Explanation    A service has successfully exited its execution.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SRVSCOPE_COMPLETED: Completed execution for scope [chars]. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SRVSCOPE_STARTED: Started execution for scope [chars]. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SRVSTATE_CHANGED: State for service [chars] changed from 
[chars] to [chars] in vdc [dec]. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SRV_ENQUEUED_FOR_START: Conditional service [chars] started 
by sap [dec] has been enqueued for start. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-6-STATE_CHANGED: System Manager state changed from [chars] to 
[chars] for vdc [dec]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SUBPROC_SUCCESS_EXIT: [chars] (PID [dec]) has successfully 
exited with exit code [chars] ([dec]).

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-6-SUPERSTATE_CHANGED: System Manager super state changed from 
[chars] to [chars] for vdc [dec]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

SYSMGR-7

Error Message     SYSMGR-7-CFGWRITE_UNEXPECTEDRSP: Discarding unexpected response from 
service [chars]. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-7-DUPLICATED_PFM_HANDSHAKE: PFM-handshake received from 
service [chars], but information already available.

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-7-LIBCDB_FAILURE: Conversion for service [chars] failed in 
libcdb. 

Explanation    This message indicates that either the system could not find conversion tarball or there is no conversion library needed for this service.

Recommended Action    No action is required.

Error Message     SYSMGR-7-LIBVDB_FAILURE: Conversion for service [chars] failed in 
libvdb. 

Explanation    This message indicates that the system could not find package information for this service in the version database.

Recommended Action    No action is required.

Error Message     SYSMGR-7-ND_UPGD_RECOVERY_SRVSUCCEEDED: Service [chars] recovered its 
state during non-disruptive upgrade. 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     SYSMGR-7-NO_STARTUP_CONFIG: No startup-config to convert. 

Explanation    This message indicates that the system tried to convert startup configuration but it found no configuration to convert.

Recommended Action    No action is required.

Error Message     SYSMGR-7-SWITCHOVER_SRVSUCCEDED: Service [chars] completed its 
switchover actions. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-7-UNEXPECTEDMSG: Opcode [dec] not expected at this time from 
service [chars] ([chars]). 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-7-UNKNOWNADDR: Opcode [dec] received from unknown source 
[chars]. Discarding. 

Explanation    This message is for Cisco TAC debugging. This is not a problem or malfunction.

Recommended Action    No action is required.

Error Message     SYSMGR-7-UNKNOWNMSG: Unknown opcode [dec] received from [chars]. 

Explanation    The System Manager has received an unrecognized message with the specified opcode. [chars] is the source of the message. This message is for debugging purposes only.

Recommended Action    No action is required.

Error Message     SYSMGR-7-UNKNOWNPID: Opcode [dec] received from [chars] with unknown 
PID [dec]. Discarding.

Explanation    The System Manager has received a message from an unknown process. [chars] is the source of the message. This message is for debugging purposes only.

Recommended Action    No action is required.

Error Message     SYSMGR-7-UNKNOWNUUID: Opcode [dec] received from [chars] with unknown 
UUID [dec]. Discarding.

Explanation    The System Manager has received an unrecognized message from the specified UUID. [chars] is the source of the message. This message is for debugging purposes only.

Recommended Action    No action is required.

SYSTEMHEALTH Messages

This section contains the SYSTEMHEALTH messages.

SYSTEMHEALTH-2

Error Message    SYSTEMHEALTH-2-OHMS_BATTERY_FAILED: Battery [dec] failed for module 
[dec]. Reason: [chars]. 

Explanation    Battery failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_BOOTFLASH_FAILED_RESET_DAY: Bootflash hard 
resets for module [dec] has reached threshold limit in 24 hours. 

Explanation    Bootflash hard resets reached threshold limit in 24 hours.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_BOOTFLASH_FAILED_RESET_LIFE: Bootflash hard 
resets for module [dec] has reached the maximum threshold limit. 

Explanation    Bootflash hard resets reached maximum threshold limit.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_BOOTFLASH_FAILED: Bootflash test maximum failures 
reached for module [dec] Reason: ([chars]). 

Explanation    Bootflash failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_CACHE_DISK_FAILED: Cache disk [dec] failed for 
module [dec]. 

Explanation    Cache disk failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_EMGMT_FAILED: Management port failed for module 
[dec]. 

Explanation    Ethernet management port failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_EOBC_FAILED: EOBC test failed for module [dec]. 

Explanation    EOBC test failed for module.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_FIPS_FAILURE: FIPS compliance error during random 
number generation. 

Explanation    FIPS compliance error.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_FREE_DISK_FAILED: Free Disk Space on partition 
[chars] is below threshold for module [dec]. 

Explanation    System Health Free Disk Space below threshold.

Recommended Action    Force a switch over if a standby supervisor is available, or reboot the switch to recover

Error Message     SYSTEMHEALTH-2-OHMS_INBAND_FAILED: Inband test maximum failures 
reached for module [dec]. 

Explanation    Inband failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_MOD_PORT_LB_TEST_FAILED: Module [dec] Port [dec] 
has failed loop back tests. 

Explanation    Port loop-back test failure.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_MOD_RELOAD_REQ: Module [dec] reload being 
requested due to errors found by [chars] test. 

Explanation    System Health Module Reload Request.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_MOD_SNAKE_TEST_FAILED: Module [dec] has failed 
snake loopback tests. 

Explanation    Snake test failure.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_NVRAM_FAILED: Nvram test maximum failures reached 
for module [dec] for blocks 0x%llx. 

Explanation    Nvram failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_FAILED: Compact Flash firmware CRC 
checksum on module [dec] is corrupted. 

Explanation    Compact flash firmware has been corrupted.

Recommended Action    Replace the compact flash on this module.

Error Message     SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_INIT_ERRORS: Compact Flash firmware 
CRC checksum procedure encountered an error during initialization on module [dec], 
reason:([chars]). 

Explanation    Compact flash CRC checksum initializations failed.

Recommended Action    Check the compact flash on the board and any relevant system (mis)configurations.

Error Message     SYSTEMHEALTH-2-OHMS_SUP_CF_REFLASH_FAILED: Compact Flash firmware 
refresh procedure failed, replace the compact flash on module [dec]. Reason [dec] 

Explanation    Compact flash firmware has been corrupted is corrupted.

Recommended Action    Replace the compact flash on this module.

Error Message     SYSTEMHEALTH-2-OHMS_SWITCHOVER_REQ: Supervisor switch over being 
requested due to errors found [chars] test. 

Explanation    System Health Switch Over Request.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_SWITCH_RELOAD_REQ: Switch reload request due to 
errors found [chars] test. 

Explanation    System Health Switch Reload Request.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-2-OHMS_TCAM_PARITY_FAILED: TCAM test failed for module 
[dec]. 

Explanation    TCAM test failed for module as uncorrectable parity errors were detected.

Recommended Action    Please schedule a downtime and replace the module.

Error Message     SYSTEMHEALTH-2-OHMS_TCAM_PARITY_OFLOW: Too many TCAM Parity errors 
detected on module [dec] 

Explanation    More parity errors than that can be corrected were detected on the affected module

Recommended Action    Please schedule a downtime and reload the module. If these errors continue to happen even after module reload, please replace the module

SYSTEMHEALTH-4

Error Message     SYSTEMHEALTH-4-OHMS_BATTERY_ERRORS: Battery test on module [dec] has 
been suspended due to internal errors. 

Explanation    Battery test internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_BOOTFLASH_TEST_ERRORS: Bootflash test cannot 
proceed due to internal errors on module [dec]. 

Explanation    Compact flash test internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_CACHE_DISK_ERRORS: Cache disk test on module 
[dec] dpp [dec] has been suspended due to internal errors. 

Explanation    Cache disk test internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_CF_CRC_PASSED: Compact Flash firmware on module 
[dec] is healthy at this time. 

Explanation    The Compact Flash model has data retention issues and need to be replaced.

Recommended Action    Please schedule a downtime and replace the compact flash on this module.

Error Message     SYSTEMHEALTH-4-OHMS_CF_REFLASH_PASSED: Compact Flash firmware was 
successfully refreshed on module [dec]. 

Explanation    The Compact Flash model has data retention issues and need to be replaced.

Recommended Action    Please schedule a downtime and replace the compact flash on this module.

Error Message     SYSTEMHEALTH-4-OHMS_EMGMT_ERRORS: Management port test cannot proceed 
due to internal errors on module [dec]. 

Explanation    Ethernet management port internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_EOBC_ERRORS: EOBC test on module [dec] has been 
suspended due to internal errors. 

Explanation    EOBC test internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_EOBC_HALTED: EOBC Test Halted for module [dec]. 
Module needs EPLD Upgrade 

Explanation    Module does not have the minimum required EPLD version to run EOBC test.

Recommended Action    Please upgrade the module with the latest EPLD's.

Error Message     SYSTEMHEALTH-4-OHMS_EXIT: Online System Health exiting due to 
internal errors. Reason [dec]. 

Explanation    Online System Health exiting due to internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_FAIL_ACTION_NOTICE: Failure action not taken, 
failure action is disabled. 

Explanation    System Health SERDES test failure.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_FREE_DISK_ERRORS: Too many errors on module [dec] 
while running the Free Disk Space test for partition [chars]. 

Explanation    System Health Free Disk Space test has too many errors while running.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_FREE_DISK_FAILING: Free Disk Space on partition 
[chars] is starting to go below threshold for module [dec] 

Explanation    System Health Free Disk Space going below threshold.

Recommended Action    Force a switch over if a standby supervisor is available, or reboot the switch to recover

Error Message     SYSTEMHEALTH-4-OHMS_INBAND_FAILING1: Inband test failed [dec] times 
for module [dec]. 

Explanation    Inband Failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_INBAND_TEST_ERRORS: Too many errors while running 
the inband test. 

Explanation    Inband test has had too many errors while running.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_LC_DAEMON_EXITED: System Health process running 
on module [dec] exited due to internal errors. Will attempt to restart. 

Explanation    System Heath line card daemon exited.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_LC_DAEMON_FAILED: System Health process running 
on module [dec] failed due to fatal errors. 

Explanation    System Heath line card daemon failed.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_LC_DAEMON_RESTARTED: System Health process 
running on module [dec] restarted. 

Explanation    System Heath line card daemon restarted.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_MOD_SNAKE_PATH_FAILURE: Snake Loopback data path 
failure on module [dec]. 

Explanation    Snake data path only error.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_MOD_SNAKE_TEST_ERRORS: Snake Loopback test cannot 
proceed due to internal errors for module [dec]. 

Explanation    Snake test internal errors.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_NVRAM_ERRORS: Too many errors on module [dec] 
while running the Nvram test. 

Explanation    Nvram test has had too many errors while running.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_SERDES_FAILED: SERDES loopback test on interface 
fc[dec]/[dec] failed. 

Explanation    System Health SERDES Test Failure.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_BOOTFLASH_ERRORS: Bootflash test has 
encountered an error on module [dec] Reason:([chars]). 

Explanation    Compact flash test errors on supervisor.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_INTERN_ERRORS: Compact flash firmware 
CRC checksum procedure cannot proceed due to internal errors on module [dec]. 

Explanation    Compact flash firmware CRC checksum procedure ended up in errors.

Recommended Action    Try restarting the cf-crc-check using system health clear-errors module <x> cf-crc-check. If the condition still persist, schedule a downtime and replace the compact flash on the affected module.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_PROCESS_ERRORS: Compact flash 
firmware CRC checksum procedure failed on module [dec]. Reason [dec] 

Explanation    Compact flash firmware CRC checksum procedure failed.

Recommended Action    Try restarting the cf-crc-check using system health clear-errors module <x> cf-crc-check. If the condition still persist, schedule a downtime and replace the compact flash on the affected module.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_TEST_FAILING: Compact flash firmware 
CRC checksum validation starting to fail on module [dec]. 

Explanation    Compact flash firmware CRC checksum might be bad on this module.

Recommended Action    Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_RECALLED: Compact Flash on module [dec] 
was recalled. 

Explanation    The Compact flash model has data retention issues and need to be replaced.

Recommended Action    Please schedule a downtime and replace the compact flash on this module.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_INTERN_ERRORS: Compact Flash 
firmware re-flash procedure cannot proceed due to internal errors on module [dec]. 

Explanation    Compact flash firmware re-flash procedure ended up in errors.

Recommended Action    Try restarting the test using system health clear-errors module <x> cf-re-flash. If the condition still persist, schedule a downtime and replace the compact flash on the affected module.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_TEST_FAILING: Compact flash 
firmware refresh procedure starting to fail on module [dec]. 

Explanation    Compact flash might be dead on this module.

Recommended Action    Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades.

Error Message     SYSTEMHEALTH-4-OHMS_SUP_CF_UNRESPONSIVE: Recalled Compact Flash on 
module [dec] is unresponsive. 

Explanation    The Compact flash model has data retention issues and need to be replaced.

Recommended Action    Please schedule a downtime and replace the compact flash on this module.

Error Message     SYSTEMHEALTH-4-OHMS_SVC_DAEMON_FAILED: System Health process running 
on module [dec] SVC node [dec] exited due to errors. 

Explanation    OHMS SVC daemon exited.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-4-OHMS_TCAM_PARITY_ACL_FIB_TIMEOUT: TCAM test timeout 
waiting for ACL/FIB to update TCAM on module [dec] 

Explanation    System health TCAM test timeout occured while waiting for response from ACL/FIB

Recommended Action    If significant packet drops are encountered in the forwarding engine, please schedule a downtime and reload the module

Error Message     SYSTEMHEALTH-4-OHMS_TCAM_PARITY_ACL_FIB_UPDATE_FAILING: Tcam test 
failed as ACL/FIB failed to update TCAM on module [dec] 

Explanation    ACL/FIB failed to update TCAM after soft parity errors were encountered.

Recommended Action    If significant packet drops are encountered in the forwarding engine, please schedule a downtime and reload the module

Error Message     SYSTEMHEALTH-4-OHMS_TCAM_PARITY_ERRORS: TCAM test on module [dec] has 
been suspended due to internal errors. 

Explanation    TCAM test internal errors.

Recommended Action    No action is required.

SYSTEMHEALTH-5

Error Message     SYSTEMHEALTH-5-OHMS_BATTERY_FAILING: Battery [dec] starting to fail 
on module [dec]. Reason: [chars]. 

Explanation    System Health battery failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_BOOTFLASH_FAILING: Bootflash starting to fail on 
module [dec]. 

Explanation    System Health bootflash failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_CDISK_FAILING: Cache disk [dec] starting to fail 
on module [dec]. 

Explanation    System Health cache disk failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_EMGMT_FAILING: Management port on module [dec] 
starting to show signs of failures. 

Explanation    System Health emgmt failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_EOBC_FAILING: EOBC starting to fail on module 
[dec]. 

Explanation    System Health eobc failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_INBAND_FAILING: Inband starting to fail on module 
[dec]. 

Explanation    System Health inband failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_NVRAM_FAILING: Nvram starting to fail on module 
[dec]. 

Explanation    System Health Nvram failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_SUP_CF_ERRORS_CLEARED: Compact flash failing 
conditions on module [dec] has been cleared. 

Explanation    Compact flash might be dead on this module.

Recommended Action    Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades.

Error Message     SYSTEMHEALTH-5-OHMS_TCAM_PARITY_CLEARED: Failing conditions for TCAM 
on module [dec] have been cleared. 

Explanation    System Health TCAM failures cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_TCAM_PARITY_FAILING: TCAM starting to fail on 
module [dec]. 

Explanation    System Health Tcam failing.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-5-OHMS_TEST_FAILING: [chars] test starting to fail on 
module [dec]. 

Explanation    System Health test failing.

Recommended Action    No action is required.

SYSTEMHEALTH-6

Error Message     SYSTEMHEALTH-6-OHMS_ASIC_FAILURE_INFO: Module [dec] Asic [chars] 
instance [dec] probable cause of failure. 

Explanation    HW failure analysis findings.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_BATTERY_CLEARED: Failing conditions for battery 
[dec] on module [dec] have been cleared. 

Explanation    System Health battery failure cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_BOOTFLASH_CLEARED: Failing conditions for 
bootflash on module [dec] have been cleared. 

Explanation    System Health bootflash failures cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_CDISK_CLEARED: Failing conditions for cache disk 
[dec] on module [dec] have been cleared. 

Explanation    System Health cache disk failure cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_EMGMT_CLEARED: Failing conditions for management 
port on module [dec] have been cleared. 

Explanation    System Health emgmt failure cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_EOBC_CLEARED: Failing conditions for EOBC on 
module [dec] have been cleared. 

Explanation    System Health eobc failures cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_FAILURE_CLEARED: Failing conditions for test 
[chars] has been cleared on module [dec]. 

Explanation    System Health failure cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_INBAND_CLEARED: Failing conditions for inband on 
module [dec] have been cleared. 

Explanation    System Health inband failures cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_INBAND_DROP: Inband Dropping frames from module 
[dec] due to unknown reasons. 

Explanation    System Health Inband non-timeout drop.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_INBAND_TO_ERR: Inband Dropping frames from module 
[dec] due to timeout errors. 

Explanation    System Health Inband timeout drop.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_INBAND_TX_CONGESTION: Inband Unable to transmit 
due to TX path congestion on module [dec]. 

Explanation    System Health Inband TX congestion.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_NVRAM_CLEARED: Failing conditions for Nvram on 
module [dec] have been cleared. 

Explanation    System Health Nvram failures cleared.

Recommended Action    No action is required.

Error Message     SYSTEMHEALTH-6-OHMS_STARTED: Online System Health started. 

Explanation    Online System Health started.

Recommended Action    No action is required.

TACACS Messages

This section contains the TACACS messages.

TACACS-2

Error Message    TACACS-2-TACACS_PROGRAM_EXIT: TACACS+ daemon exiting: [chars] 

Explanation    TACACS+ daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

TACACS-3

Error Message     TACACS-3-TACACS_ERROR_MESSAGE: [chars] 

Explanation    TACACS+ Error Message

Recommended Action    No action is required.

TACACS-5

Error Message     TACACS-5-TACACS_MONITOR_STATUS: [chars] [chars] 

Explanation    Notifying Tacacs+ server monitor status change

Recommended Action    No action is required.

Error Message     TACACS-5-TACACS_NOTIFICATION: [chars] 

Explanation    TACACS+ notification

Recommended Action    No action is required.

Error Message     TACACS-5-TACACS_SERVER_STATUS: [chars] server [chars] with auth-port 
[dec] and acct-port [dec] status has changed from [chars] to [chars]. Server was 
in previous-state for [chars], and total dead time of the server is [chars] 

Explanation    Notifying Tacacs+ server status change

Recommended Action    No action is required.

TACACS-6

Error Message     TACACS-6-TACACS_ACCOUNTING_MESSAGE: [chars] 

Explanation    Accounting Message

Recommended Action    No action is required.

Error Message     TACACS-6-TACACS_MESSAGE: [chars] 

Explanation    TACACS+ Message

Recommended Action    No action is required.

TCAP Messages

This section contains the TCAP messages.

TCAP-2

Error Message    TCAP-2-MEM_FULL: Memory allocation failed. 

Explanation    TCAP process has failed to allocate memory.

Recommended Action    Please perform a 'show tcap event-history' to collect more information.

Error Message     TCAP-2-PROC_DN: Process is shutting down: [chars] 

Explanation    TCAP process is exiting.

Recommended Action    Please perform a 'show tcap event-history' to collect more information.

Error Message     TCAP-2-PROC_INITFAIL: Process initialization failed due to [chars]. 

Explanation    TCAP process has failed initialization.

Recommended Action    Please perform a 'show tcap event-history' to collect more information.

TLPORT Messages

This section contains the TLPORT messages.

TLPORT-2

Error Message    TLPORT-2-INITFAIL: TL Port Manager Initialization failed: [chars] 

Explanation    TL Port Manager initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

TLPORT-3

Error Message     TLPORT-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    TL Port Manager is out of dynamic memory. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

Error Message     TLPORT-3-FC2ERROR: [chars] 

Explanation    TL Port Manager encountered an FC2 error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

Error Message     TLPORT-3-GENERROR: [chars] 

Explanation    TL Port Manager encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     TLPORT-3-MTSERROR: [chars] 

Explanation    TL Port Manager encountered an MTS error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

Error Message     TLPORT-3-PSSERROR: [chars] 

Explanation    TL Port Manager encountered a PSS error. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

TLPORT-4

Error Message     TLPORT-4-TLPM_ALPA_CACHE_FULL: Translation Port ALPA cache is full. 
Some new entries may not be cached

Explanation    TL Port cache is currently fully populated with active entries. Hence, there is no available cache space to be assigned any newly created alpa entry on a TL Port. This is an informational message.

Recommended Action    No action is required.

TLPORT-6

Error Message     TLPORT-6-MGRCREATED: Translation Port Manager created. 

Explanation    TL Port Manager was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     TLPORT-6-MGREXIT: Translation Port Manager shutting down gracefully. 

Explanation    TL Port Manager is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     TLPORT-6-PORTDOWN: Translation Port [chars] DOWN. 

Explanation    A port configured as TL Port is DOWN and out of operation. [chars] is the interface-id string that identifies the TL Port. This is an informational message.

Recommended Action    No action is required.

Error Message     TLPORT-6-PORTUP: Translation Port [chars] UP. 

Explanation    A port configured as TL Port is UP and operational. [chars] is the interface-id string that identifies the TL Port. This is an informational message.

Recommended Action    No action is required.

TPC Messages

This section contains the TPC messages.

TPC-SLOT#-5

Error Message    TPC-SLOT#-5-LOG_ERR_TPC_DPP_DEAD: VSAN :[dec] VT pWWN :[chars] DPP 
died 

Explanation    The DPP associated with the Virtual Target has crashed

Recommended Action    No action is required.

Error Message     TPC-SLOT#-5-LOG_ERR_TPC_VT_ACT_FAILED: VSAN :[dec] VT pWWN :[chars] 
VT Activate failed 

Explanation    The activate step for a Virtual Target has failed

Recommended Action    No action is required.

Error Message     TPC-SLOT#-5-LOG_ERR_TPC_VT_CREATE_FAIL: VSAN :[dec] VT pWWN :[chars] 
VT and NPort creation FAILED !!! 

Explanation    The Virtual Target and nport creation failed

Recommended Action    No action is required.

Error Message     TPC-SLOT#-5-LOG_ERR_TPC_VT_DESTROYED: VSAN :[dec] Virtual Target : 
[chars] Deleted 

Explanation    The Virtual Target in the associated VSAN is being destroyed

Recommended Action    No action is required.

Error Message     TPC-SLOT#-5-LOG_ERR_TPC_VT_VSAN_DOWN: VSAN :[dec] VT pWWN :[chars] 
VSAN down 

Explanation    The VSAN where the Virtual Target is configured is down

Recommended Action    No action is required.

TTYD Messages

This section contains the TTYD messages.

TTYD-2

Error Message    TTYD-2-TTYD_ERROR: TTYD Error [chars] 

Explanation    Critical TTY daemon error.

Recommended Action    No action is required.

Error Message     TTYD-2-TTYD_MTS: TTYD Message queue [dec] [chars] 

Explanation    TTY daemon message error.

Recommended Action    No action is required.

Error Message     TTYD-2-TTYD_SDWRAP: TTYD Debug Facility error [dec] [chars] 

Explanation    TTY daemon Debug Facility failed.

Recommended Action    No action is required.

TTYD-3

Error Message     TTYD-3-TTYD_MISC_ERROR: Error [chars] with error [chars]([hex]) 

Explanation    TTY daemon errors.

Recommended Action    No action is required.

TTYD-6

Error Message     TTYD-6-TTYD_MISC: TTYD [chars] 

Explanation    The tty daemon miscellaneous message.

Recommended Action    No action is required.

Error Message     TTYD-6-TTYD_PSS: TTYD Store error:[hex] [chars] 

Explanation    Failed to store configuration for TTY service.

Recommended Action    No action is required.

TUNNEL Messages

This section contains the TUNNEL messages.

TUNNEL-3

Error Message    TUNNEL-3-HW_PROGRAMMING_FAILED: for [chars], reason [chars] 

Explanation    Hardware programming failed for tunnel [num] interface

Recommended Action    Try 'shutdown' and 'no shutdown' under tunnel interface submode after sometime. if still tunnel interface doesn't come up capture show tech-support tunnel to identify the issue

TUNNEL-4

Error Message     TUNNEL-4-TM_DF_PROGRAMMING_FAILED: [chars] DF(dont fragment) 
programming failed! status [hex] 

Explanation    [chars] DF programming failed! status [int]

Recommended Action    Capture show tech-support tunnel to identify why df flag programing failed

Error Message     TUNNEL-4-TM_DF_PROGRAMMING: Programming [chars] DF(dont fragment) 
df.sel [dec] df.val [dec] 

Explanation    Programming [chars] DF df.sel [int] df.val [int]

Recommended Action    No action is required.

Error Message     TUNNEL-4-TM_MTU_PROGRAMMING_FAILED: [chars] mtu [dec] programming 
failed! status [hex] 

Explanation    [chars] mtu [int] programming failed! status [int]

Recommended Action    Capture show tech-support tunnel to identify why MTU programming as failed. tunnel interface will used default mtu value

Error Message     TUNNEL-4-TM_MTU_PROGRAMMING: Programming [chars] mtu [dec]... 

Explanation    Programming [chars] mtu [int]

Recommended Action    No action is required.

TUNNEL-5

Error Message     TUNNEL-5-IF_CLEAR_COUNTER: Interface [chars] counters is cleared 

Explanation    Interface [char] counters is cleared

Recommended Action    No action is required.

Error Message     TUNNEL-5-IF_CREATED: Interface [chars] is created 

Explanation    Interface [char] is created

Recommended Action    No action is required.

Error Message     TUNNEL-5-IF_CREATE_FAILED: Interface [chars] creation failed due to 
[[hex]] [chars] 

Explanation    Interface [char] is creation failed due to [int] [char]

Recommended Action    No action is required.

Error Message     TUNNEL-5-IF_DELETED: Interface [chars] is deleted 

Explanation    Interface [char] is deleted

Recommended Action    No action is required.

Error Message     TUNNEL-5-IF_STATE_UPDATE: Interface [chars] is [chars] reason [chars] 

Explanation    Interface [char] is [char] reason [char]

Recommended Action    No action is required.

Error Message     TUNNEL-5-PPF_SESSION_FAILED: session id %llx type [chars] for [chars] 
failed error [hex] [chars] 

Explanation    Session id [int] type [char] for [char] failed error [int] [char]

Recommended Action    No action is required.

Error Message     TUNNEL-5-TM_DISABLED: Tunnel Disabled 

Explanation    Tunnel Service Disabled

Recommended Action    No action is required.

Error Message     TUNNEL-5-TM_ENABLED: Tunnel Enabled 

Explanation    Tunnel Service Enabled

Recommended Action    No action is required.

TUNNEL-7

Error Message     TUNNEL-7-TM_INFO: [chars] 

Explanation    Tunnel Service info

Recommended Action    No action is required.

UDLD Messages

This section contains the UDLD messages.

UDLD-3

Error Message    UDLD-3-IDB_ERROR: UDLD error handling [chars] interface: [chars] 

Explanation    A softare error occurred in UDLD processing associated with a specific interface.

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-3-MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: [chars] 

Explanation    Failed to send a message

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-3-UDLD_INTERNAL_ERROR: UDLD internal error: [chars] 

Explanation    A softare sanity check failed in the course of UDLD processing.

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-3-UDLD_INTERNAL_IF_ERROR: UDLD internal error, interface 
[chars]: [chars] 

Explanation    A softare sanity check failed in the course of UDLD processing.

Recommended Action    LOG_STD_SH_TECH_ACTION

UDLD-4

Error Message     UDLD-4-UDLD_GWRAP_COUNT: UDLD gwrap count is %lu, please log a 'show 
tech udld' for detail info. 

Explanation    UDLD gwrap count reached high level, show tech udld is needed to debug it.

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-4-UDLD_NEIGHBOR_MISMATCH: UDLD neighbor mismatch detected, exp: 
[chars], rec [chars] 

Explanation    An interface will be disabled because UDLD protocol detected a nieghbor mismatch condition on the interface indicated. Cause is likely due to bad interface hardware or cable misconfiguration. User should investigate.

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-4-UDLD_PORT_DISABLED: UDLD disabled interface [chars], [chars] 
detected 

Explanation    An interface was disabled because UDLD protocol detected the cause on the interface indicated. Cause is likely due to bad interface hardware or cable misconfiguration. User should investigate.

Recommended Action    LOG_STD_SH_TECH_ACTION

Error Message     UDLD-4-UDLD_PORT_RESET: UDLD reset interface [chars] 

Explanation    A port which had been disabled for UDLD has been reset.

Recommended Action    LOG_STD_SH_TECH_ACTION

UDLD-5

Error Message     UDLD-5-UDLD_AGGRESSIVE: UDLD Aggressive 

Explanation    UDLD Service Aggressive

Recommended Action    No action is required.

Error Message     UDLD-5-UDLD_DISABLED: UDLD Disabled 

Explanation    UDLD Service Disabled

Recommended Action    No action is required.

Error Message     UDLD-5-UDLD_ENABLED: UDLD Enabled 

Explanation    UDLD Service Enabled

Recommended Action    No action is required.

UFDM Messages

This section contains the UFDM messages.

UFDM-2

Error Message    UFDM-2-DNLD_TIMEDOUT: Download timer expired: [chars] 

Explanation    UFDM download timer expired. Collect show tech-support forwarding l3 unicast for futher analysis.

Recommended Action    No action is required.

Error Message     UFDM-2-FIB_ROUTE_UPDATE_ERR: Route update error from slot [dec] FIB 

Explanation    FIB returned route update error. Collect show tech-support forwarding l3 unicast for futher analysis.

Recommended Action    No action is required.

Error Message     UFDM-2-INTERNAL_ERROR: Internal error: [chars], collect output of 
show tech-support fowarding l3 unicast... command

Explanation    UFDM hit a internal error. Collect show tech-support forwarding l3 unicast for futher analysis.

Recommended Action    No action is required.

VDC_MGR Messages

This section contains the VDC_MGR messages.

VDC_MGR-2

Error Message    VDC_MGR-2-VDC_CRITICAL: vdc_mgr has hit a critical error: [chars] 

Explanation    Vdc_mgr has hit a critical error

Recommended Action    A critical error has been hit within vdc_mgr. Please check show vdc to determine the state of the vdcs

Error Message     VDC_MGR-2-VDC_LIC_WARN_EXP: WARNING License for vdcs is about to 
expire! VDCs will be deleted if license is allowed to expire 

Explanation    VDC license is close to expire

Recommended Action    Please contact your sales representative to obtain a license

Error Message     VDC_MGR-2-VDC_LIC_WARN: Service using grace period will be shutdown 
in [dec] day(s) 

Explanation    The license for vdcs is not installed and currently running in the grace period

Recommended Action    Vdcs will continue to work within the grace period, but obtaining a license is reccomended

Error Message     VDC_MGR-2-VDC_OFFLINE: vdc [dec] is now offline 

Explanation    The vdcd has been shut down. Either it has been deleted or has just completed ungraceful cleanup

Recommended Action    If the vdc was deleted, no action is necessary. Otherwise vdc_mgr may attempt to recreate it according to the ha-policy that has been set

Error Message     VDC_MGR-2-VDC_ONLINE: vdc [dec] has come online 

Explanation    Vdc_mgr has finished creating a vdc and it is ready to use

Recommended Action    No action is required.

Error Message     VDC_MGR-2-VDC_UNGRACEFUL: vdc_mgr: Ungraceful cleanup request 
recieved for vdc [dec], restart count for this vdc is [dec] 

Explanation    Vdc_mgr has begun ungraceful cleanup for a vdc

Recommended Action    There has been a failure within the vdc and vdc_mgr has begun the cleanup process. Use show vdc to determine its state

VDC_MGR-3

Error Message     VDC_MGR-3-FILE_WRITE_FAILED: Writing to file [chars] failed - error: 
[chars] 

Explanation    Writing to a file failed probably due to no space.

Recommended Action    Vdc_mgr

Error Message     VDC_MGR-3-VDC_ERROR: vdc_mgr: [chars] 

Explanation    Vdc_mgr has recieved bad data but will try to continue

Recommended Action    Vdc_mgr will attempt to correct the error at hand

VDC_MGR-6

Error Message     VDC_MGR-6-VDC_HOSTNAME_CHANGE: vdc [dec] hostname changed to [chars] 

Explanation    Host name for a vdc has changed.

Recommended Action    No action is required.

Error Message     VDC_MGR-6-VDC_STATE_CHANGE: vdc [dec] state changed to [chars] 

Explanation    A vdc state change has happened. This is most likely due to a configuration change.

Recommended Action    No action is required.

VEC Messages

This section contains the VEC messages.

VEC-SLOT#-3

Error Message    VEC-SLOT#-3-LOG_DPP_EXCEPTION: DPP Exception DPP [dec] 

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     VEC-SLOT#-3-LOG_GUID_MISMATCH: GUID Mismatch DPP [dec] PWWN [chars] 
lun [chars] Expected [chars] Read [chars] 

Explanation    The disk GUID verification performed by the DPP failed. Access to the disk is denied.

Recommended Action    No action is required.

VEC-SLOT#-4

Error Message     VEC-SLOT#-4-LOG_DPP_REBOOTED: DPP [dec] Rebooted 

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

VEC-SLOT#-5

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_DISK: SCSI STATUS([hex]) [chars] 
SENSE_KEY([hex]) [chars] ASC([hex]) ASCQ([hex]) [chars]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_DPP_MON_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC DPP Monitor FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_DPRLI_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC DPRLI FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_GID_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC Guid ID FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_HOST_LMAP_FSM: Illegal Event [chars] in State 
[chars] Host VSAN :[dec] Host pWWN :[chars] VEP pWWN :[chars]

Explanation    An Event is received for a State in the VEC HOST LMAP XP FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_HOST_LOGO: Logging out Host [VSAN :[dec] pWWN 
:[chars]] logged in to VEP [pWWN :[chars]]. Reason : Host not responding

Explanation    The Host HBA is logged out from the VEP as it is not responding to ADISCs initiated from the VEP

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_HOST_XP_FSM: Illegal Event [chars] in State 
[chars] Host VSAN :[dec] Host pWWN :[chars] VEP pWWN :[chars]

Explanation    An Event is received for a State in the VEC HOST XP FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_HOST: Host VSAN :[dec] Host pWWN :[chars] 
access denied to VEP pWWN :[chars] due to licensing

Explanation    The Host HBA is denied access to the VEP due to licensing

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_NPORT_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC NPORT FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_PID_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC PID FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_TARGET_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC TARGET FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_TCAM_MON_FSM: Illegal Event [chars] in State 
[chars] DPP :[dec]

Explanation    An Event is received for a State in the VEC TCAM MON FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_TP_FSM: Illegal Event [chars] in State 
[chars] Host VSAN :[dec] TP nWWN :[chars] TP pWWN :[chars]

Explanation    An Event is received for a State in the VEC TP FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VEP_FSM: Illegal Event [chars] in State 
[chars] Host VSAN :[dec] VEP nWWN :[chars] VEP pWWN :[chars]

Explanation    An Event is received for a State in the VEC VEP FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VEP_ILC_LIMIT: VEP [VSAN :[dec] pWWN 
:[chars]] could not be created. Reason : ILC VEP limit [dec] reached

Explanation    The VEP could not be created as the per ILC limit of VEPs has been reached

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VLUN_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC VLUN FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VO_FSM: Illegal Event [chars] in State 
[chars] FSM [chars] 

Explanation    An Event is received for a State in the VEC VO FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VSAN_FSM: Illegal Event [chars] in State 
[chars] VSAN [dec] 

Explanation    An Event is received for a State in the VEC VSAN FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_ERR_VEC_VSAN_XCHG_FSM: Illegal Event [chars] in State 
[chars] VES IP Addr [chars] 

Explanation    An Event is received for a State in the VEC VSAN XCHG FSM which should not have occured

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_NOTICE_VEC_SLEEP_THRESH: VEC not scheduled for [dec] 
seconds 

Explanation    The VEC process sleep threshold was exceeded which should not have occured. Recovery will be preformed if appropriate.

Recommended Action    No action is required.

Error Message     VEC-SLOT#-5-LOG_NOTICE_VEC_WORK_THRESH: VEC did not yeild the cpu for 
[dec] seconds 

Explanation    The VEC process work threshold was exceeded which should not have occured. Recovery will be preformed if appropriate.

Recommended Action    No action is required.

VEDB_MGR Messages

This section contains the VEDB_MGR messages.

VEDB_MGR-2

Error Message    VEDB_MGR-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The VEDB library could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

VEDB_MGR-6

Error Message     VEDB_MGR-6-EXITING: Exited due to [chars] 

Explanation    The VEDB library has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     VEDB_MGR-6-SERVICE_UP: Initialized [chars] 

Explanation    The VEDB library is up and ready to accept client requests The service was initialized in [char] mode.

Recommended Action    No action is required.

VEM_MGR Messages

This section contains the VEM_MGR messages.

VEM_MGR-2

Error Message    VEM_MGR-2-MOD_OFFLINE: Module [dec] is offline 

Explanation    VEM module is offline

Recommended Action    No action is required.

Error Message     VEM_MGR-2-MOD_ONLINE: Module [dec] is online 

Explanation    VEM module is online

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_DENY_ROLLING: Module [dec] cannot be inserted 
because system is in rolling upgrade mode 

Explanation    In rolling upgrade only the hosts with the same version as VSM can get inserted

Recommended Action    You can see the host/module status in 'show module' command. In the configuration mode please change the upgrade mode to normal by 'upgrade mode normal' command or upgrade the host to the same version as VSM.

Error Message     VEM_MGR-2-VEM_MGR_DENY: Host [chars] cannot be inserted because all 
vem slots are in use. 

Explanation    All vem slots have been allocated to hosts and a new host has been added to the DVS.

Recommended Action    You can see the host/module mappings using the 'show module vem mapping' command. In the configuration mode please remove any unused hosts using the 'no vem <module>' command to free up vem slots.

Error Message     VEM_MGR-2-VEM_MGR_DETECTED: Host [chars] detected as module [dec] 

Explanation    VEM detected as a module

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_NOT_BC: Module [dec] cannot be inserted because it 
is not backward compatible 

Explanation    Only modules with version compatible to VSM version and equal greater than the current feature level can get inserted.

Recommended Action    You can see the host/module status in 'show module' command. Upgrade the module to a compatible version.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_MOD_FAIL: Removing VEM [dec] (failed module) 

Explanation    Removing VEM because module failed

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_NO_HB: Removing VEM [dec] (heartbeats lost) 

Explanation    Removing VEM because heartbeats lost

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_RESET: Removing VEM [dec] (VEM reset) 

Explanation    Removing VEM because of reset request

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM [dec] due to 
state conflict VSM([chars]), VEM([chars]) 

Explanation    Removing VEM because of state conflict

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_SUPSWITCH: Removing VEM [dec] (Switchover 
failure) 

Explanation    Removing VEM because of switchover failure

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_TWO_ACT_VSM: Removing VEM [dec] (Two active 
VSM) 

Explanation    Removing VEM because of two active VSM

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_TX_ERR: Removing VEM [dec] (transmit timeout 
- [chars]) 

Explanation    Removing VEM because of transmit timeout

Recommended Action    You can collect information about the transmit timeout using command 'show hardware internal aipc event-history msgs'. The event logged will be E_AIPC_TXTIMEOUT.

Error Message     VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM [dec] 
(Unexpected Node Id Request) 

Explanation    Removing VEM because of unexpected Node Id Request

Recommended Action    No action is required.

Error Message     VEM_MGR-2-VEM_MGR_UNLICENSED: License for VEM [dec] could not be 
obtained. Please contact your Cisco account team or partner to purchase Licenses. 
To activate your purchased licenses, click on www.cisco.com/go/license.

Explanation    VEM License could not be obtained

Recommended Action    Please contact your sales representative to obtain a license

Error Message     VEM_MGR-2-VEM_MGR_VERSION_FILE_MISSING: The version file in [chars] 
could not be opened 

Explanation    The version file could not be opened

Recommended Action    No action is required.

VEM_MGR-3

Error Message     VEM_MGR-3-VEM_MGR_ATTACH_FAIL: Some interfaces on module [dec] might 
not be up, attaching not completed 

Explanation    Attaching not completed in time for some of the interfaces on this module. Please verify the configuration of the port-profiles that are associated to these interfaces

Recommended Action    No action is required.

VEM_MGR-5

Error Message     VEM_MGR-5-VEM_MGR_CLOCK_CHANGE: Clock setting has been changed on the 
system. Please be aware that clock changes will force a recheckout of all existing 
VEM licenses. During this recheckout procedure, licensed VEMs which are offline 
will lose their licenses.

Explanation    Clock setting has been changed on the system. Please be aware that clock changes will force a recheckout of all existing VEM licenses. During this recheckout procedure, licensed VEMs which are offline will lose their licenses.

Recommended Action    No action is required.

Error Message     VEM_MGR-5-VEM_MGR_LVV_CHANGE: VEM feature level is changed from 
[chars] to [chars] 

Explanation    VEM feature level is changed

Recommended Action    No action is required.

VEM_MGR-6

Error Message     VEM_MGR-6-VEM_MGR_LIC_CHECKIN: Licenses for Slot [dec] are being 
checked in. 

Explanation    Licenses are being checked in for the slot

Recommended Action    No action is required.

Error Message     VEM_MGR-6-VEM_MGR_LIC_RECHECKOUT: Licenses for VEM [dec] are being 
rechecked out due to [chars]. 

Explanation    Licenses are being rechecked out from license manager

Recommended Action    No action is required.

VES Messages

This section contains the VES messages.

VES-SLOT#-4

Error Message    VES-SLOT#-4-LOG_WARNING_VES_CONFIG_TOO_BIG: Volume [chars] 
configuration too large to virtualize 

Explanation    The VES maximum volume configuration was exceeded. Volume will be virtualized by the cpp.

Recommended Action    No action is required.

VES-SLOT#-5

Error Message     VES-SLOT#-5-LOG_ERR_VES_PATH_FSM: disk guids dont match - received 
verify_mismatch for pid [dec] from vec [dec] 

Explanation    An VERIFY MISMATCH Event is received for a State in the VES PATH FSM which should not have occured

Recommended Action    No action is required.

Error Message     VES-SLOT#-5-LOG_ERR_VES_VEP_FSM: Illegal Event [chars] in State 
[chars] Host VSAN :[dec] VEP pWWN :[chars]

Explanation    An Event is received for a State in the VES VEP FSM which should not have occured

Recommended Action    No action is required.

Error Message     VES-SLOT#-5-LOG_ERR_VES_VSAN_FSM: Illegal Event [chars] in State 
[chars] VSAN [dec] 

Explanation    An Event is received for a State in the VES VSAN FSM which should not have occured

Recommended Action    No action is required.

Error Message     VES-SLOT#-5-LOG_ERR_VES_VSAN_XCHG_FSM: Illegal Event [chars] in State 
[chars] VEC IP Addr [chars] 

Explanation    An Event is received for a State in the VES VSAN XCHG FSM which should not have occured

Recommended Action    No action is required.

Error Message     VES-SLOT#-5-LOG_NOTICE_VES_SLEEP_THRESH: VES not scheduled for [dec] 
seconds 

Explanation    The VES process sleep threshold was exceeded which should not have occured. Recovery will be preformed if appropriate.

Recommended Action    No action is required.

Error Message     VES-SLOT#-5-LOG_NOTICE_VES_WORK_THRESH: VES did not yeild the cpu for 
[dec] seconds 

Explanation    The VES process work threshold was exceeded which should not have occured. Recovery will be preformed if appropriate.

Recommended Action    No action is required.

VFC Messages

This section contains the VFC messages.

VFC-3

Error Message    VFC-3-VFC_MEM_ERROR: Memory consistency problem 

Explanation    Miscellaneous target error

Recommended Action    No action is required.

Error Message     VFC-3-VFC_TGT_ERROR: Target error:[chars] 0x%llx 

Explanation    Miscellaneous target error

Recommended Action    No action is required.

VFC-6

Error Message     VFC-6-STARTING: deamon started 

Explanation    The VFC daemon successfully started

Recommended Action    No action is required.

VIM Messages

This section contains the VIM messages.

VIM-5

Error Message    VIM-5-IF_ATTACHED: Interface [chars] is attached to [chars] on [chars] 

Explanation    Interface has been attached

Recommended Action    No action is required.

Error Message     VIM-5-IF_CONFIG_PURGE_AUTO: Configuration on interface [chars] has 
been auto purged ([chars]) 

Explanation    Configuration on interface has been auto purged

Recommended Action    No action is required.

Error Message     VIM-5-IF_DELETE_AUTO: Interface [chars] has been auto deleted 

Explanation    Interface has been auto deleted as it is no longer in use

Recommended Action    No action is required.

Error Message     VIM-5-IF_DELETE_CONFLICT: Interface [chars] conflicts with another 
interface on the peer vPC switch 

Explanation    Interface has been deleted

Recommended Action    No action is required.

Error Message     VIM-5-IF_DELETE_INIT_FAIL: Interface [chars] has been deleted due to 
init failure 

Explanation    Interface has been deleted due to an error which occurred during port initialization

Recommended Action    No action is required.

Error Message     VIM-5-IF_DELETE_USER: Interface [chars] has been manually deleted 

Explanation    Interface has been manually deleted by the user

Recommended Action    No action is required.

Error Message     VIM-5-IF_DETACHED_IF_REMOVED: Interface [chars] is detached 
(interface removed) 

Explanation    Interface has been detached because the interface was removed

Recommended Action    No action is required.

Error Message     VIM-5-IF_DETACHED_MODULE_REMOVED: Interface [chars] is detached 
(module removed) 

Explanation    Interface has been detached because the module was removed

Recommended Action    No action is required.

Error Message     VIM-5-IF_DETACHED: Interface [chars] is detached 

Explanation    Interface has been detached

Recommended Action    No action is required.

Error Message     VIM-5-VM_VEM_VMOTION_COMPLETE: VM with VM-ID ([chars]) and VM-Name 
([chars]) has migrated from Module [dec] to Module [dec]. The veths attached to 
this VM are : [chars]

Explanation    VM has completed a VMOTION from one ESX host to another

Recommended Action    No action is required.

Error Message     VIM-SLOT#-5-IF_NO_ISCSI: The iscsi-multipath feature inherited on 
interface [chars] is not supported on VEM with host version [chars]; feature 
configuration ignored.

Explanation    ISCSI multipath is implemented only on VEMs runnning on ESX version 4.0 update 1 or greater.

Recommended Action    No action is required.

VLAN_MGR Messages

This section contains the VLAN_MGR messages.

VLAN_MGR-2

Error Message    VLAN_MGR-2-ERROR_MSG: [chars] 

Explanation    VLAN manager error

Recommended Action    No action is required.

Error Message     VLAN_MGR-2-INFO_MSG: [chars] 

Explanation    VLAN manager info

Recommended Action    No action is required.

Error Message     VLAN_MGR-2-VLAN_MGR_SAME_VLAN_PORTS: Interface [chars] and [chars] 
may configured with same VLANs. If they are not a Ether-channel member port, this 
configuration is not supported on N1K and may result in network instability. Please 
correct it. 

Explanation    On a module, configuring more than one physical ethernet interface(non Ether-channel member port) with same VLANs results in a loop and network instability.

Recommended Action    Correct the mis-configuration by removing the conflicting VLANs from one of the interface if its present

Error Message     VLAN_MGR-2-WARN_MSG: [chars] 

Explanation    VLAN manager warning

Recommended Action    No action is required.

VLAN_MGR-6

Error Message     VLAN_MGR-6-VLAN_CREATED: VLAN [dec], created 

Explanation    VLAN created

Recommended Action    No action is required.

Error Message     VLAN_MGR-6-VLAN_MGR_STATEFULL_RESTART: VLAN Manager statefull restart 

Explanation    VLAN Manager statefull restart

Recommended Action    No action is required.

Error Message     VLAN_MGR-6-VLAN_MGR_STATELESS_RESTART: VLAN Manager stateless restart 

Explanation    VLAN Manager stateless restart

Recommended Action    No action is required.

Error Message     VLAN_MGR-6-VLAN_OPER_STATUS_CHG: VLAN [dec], status changed to 
[chars] 

Explanation    VLAN operational state change

Recommended Action    No action is required.

VMM Messages

This section contains the VMM messages.

VMM-2

Error Message    VMM-2-VMM_SERVICE_ERR: VDC[dec]: Service SAP [dec] returned error 
[hex] ([chars]) in [chars] sequence 

Explanation    Service returned error in the specified sequence

Recommended Action    No action is required.

Error Message     VMM-2-VMM_TIMEOUT: VDC[dec]: Service SAP [dec] timeouted in [chars] 
sequence 

Explanation    Service did not respond in the specified sequence

Recommended Action    No action is required.

VMS Messages

This section contains the VMS messages.

VMS-2

Error Message    VMS-2-FORCE_DISCONNECT: Attempt to resync Port-Profile manager failed. 
Disconnecting from vCenter server. Please try to re-connect or reload the VSM to 
recover

Explanation    Disconnected from the vCenter Server due to an inconsistency with the Port-Profile Manager.

Recommended Action    Connection has been dropped due to an inconsistency between the portgroups on the vCenter Server and the local Port-Profile Manager. Possible actions to resolve this issue: (1) Attempt a 'no connect' and a 'connect' to resync the data (2) If Standby VSM present - perform 'system switchover' to standby (3) If Standby VSM not present - perform 'reload' of the VSM

VMS-3

Error Message     VMS-3-CONNECTION_ERROR: Unable to communicate with vCenter 
Server/ESX. Disconnecting.. 

Explanation    Communication with vCenter Server via HTTPS failed when making VIM service call. SVS will disconnect.

Recommended Action    Starting poll to reconnect to vCenter Server. If it does not work, Admin has to fix the problem and do manual connect again

Error Message     VMS-3-CONN_CONNECT_ERR: Connection '[chars]' failed to connect to the 
vCenter Server. 

Explanation    Failed to connect to the vCenter Server.

Recommended Action    Connection could fail because of multiple reasons. Check if there is network connectivity by pinging vCenter Server. Make sure the CP extension file is registered in the vCenter Server

Error Message     VMS-3-DVPG_NICS_MOVED: '[dec]' nics have been moved from port-group 
'[chars]' to '[chars]'. 

Explanation    When deleting the port-group or changing the capability of the port-group, the nics attached to this port-group are being moved out to the Quarantine port-groups

Recommended Action    Nics should be removed from the Quarantine port-groups on vCenter Server and re-assigned to the required port-group

Error Message     VMS-3-DVS_CFG_DATA_SZ_EXCEEDED: Not all system port-profiles were 
added to the switch configuration data due to its size limit. 

Explanation    Not all system port-profiles were added because doing so would cause the switch configuration data to exceed its size limit. The missing system port-profile config could result in loss of VEM connectivity with VSM, vCenter Server or others.

Recommended Action    Please reduce the number of system port-profiles. System VLANS and profiles should be used sparingly. For more information about system port-profiles see the Cisco Nexus1000V Port Profile Configuration Guide.

Error Message     VMS-3-DVS_UPDATE_ERROR: Unable to Update N1KV DVS in the VMware 
vCenter Error: [chars]

Explanation    Dvs.reconfigure failed in the Vmware vCenter when trying to update dvsname/opaquedata /uplinkportgroup.

Recommended Action    If the DVS Name already exists, then choose different name.If not, try no connect/connect again.

Error Message     VMS-3-MALLOC_FAIL: Failed to allocate memory for '[chars]'. 

Explanation    Failed to allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

VMS-5

Error Message     VMS-5-CONN_CONNECT: Connection '[chars]' connected to the vCenter 
Server. 

Explanation    Connection established to the vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-CONN_CREATE: Connection '[chars]' created. 

Explanation    New connection configured by user.

Recommended Action    No action is required.

Error Message     VMS-5-CONN_DELETE: Connection '[chars]' deleted. 

Explanation    Connection configuration deleted by user.

Recommended Action    No action is required.

Error Message     VMS-5-CONN_DISCONNECT: Connection '[chars]' disconnected from the 
vCenter Server. 

Explanation    Disconnected from the vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-DVPG_CREATE: created port-group '[chars]' on the vCenter 
Server. 

Explanation    Created a new port group on vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-DVPG_DELETE: deleted port-group '[chars]' from the vCenter 
Server. 

Explanation    Deleted port group from vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-DVPG_RENAME: renamed port-group '[chars]' to '[chars]' on the 
vCenter Server. 

Explanation    Renamed port group on vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-DVS_CREATE: dvswitch '[chars]' created on the vCenter Server. 

Explanation    New dvswitch created.

Recommended Action    No action is required.

Error Message     VMS-5-DVS_DELETE: dvswitch '[chars]' deleted from the vCenter Server. 

Explanation    Dvswitch deleted.

Recommended Action    No action is required.

Error Message     VMS-5-DVS_HOSTMEMBER_INFO: [chars] 

Explanation    DVS HostMember Information

Recommended Action    No action is required.

Error Message     VMS-5-DVS_NAME_CHANGE: Changed dvswitch name to '[chars]' on the 
vCenter Server. 

Explanation    Dvswitch name changed.

Recommended Action    No action is required.

Error Message     VMS-5-DVS_UPGRADE_INFO: [chars] 

Explanation    DVS Upgrade Information

Recommended Action    No action is required.

Error Message     VMS-5-VMS_PPM_MISMATCH: vCenter Server cache due to inconsistent 
values 

Explanation    The local cache of System Port-Profiles from the vCenter Server does not match the number of System Port-Profiles in the Port-Profile Manager

Recommended Action    No action is required.

Error Message     VMS-5-VMS_PPM_SYNC_COMPLETE: Sync between Port-Profile Manager and 
local vCenter Server cache complete

Explanation    The local cache of System Port-Profiles from the vCenter Server has completed the synced with Port-Profile Manager

Recommended Action    No action is required.

Error Message     VMS-5-VMS_PPM_SYNC_TIME_EXP: vCenter Server cache due to sync timer 
expiration 

Explanation    The timer expired while waiting for Port-Profile Manager to complete its synchronization with the vCenter cache

Recommended Action    No action is required.

Error Message     VMS-5-VMS_VUM_COMPLETE_WARNING: User Needs to execute 'vmware vem 
upgrade complete' 

Explanation    The User has executed 'vmware vem upgrade proceed'. Following this , the user needs to execute 'vmware vem upgrade complete'

Recommended Action    No action is required.

Error Message     VMS-5-VMS_VUM_PROCEED_WARNING: User Needs to execute 'vmware vem 
upgrade proceed' 

Explanation    The User has executed 'vmware vem upgrade notify'. Following this , the user needs to execute 'vmware vem upgrade notify'

Recommended Action    No action is required.

Error Message     VMS-5-VNIC_CREATE: created vnic '[chars]' with dvport_id '[chars]' on 
the vCenter Server. 

Explanation    Created a new vnic on vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-VNIC_DELETE: deleted vnic '[chars]' from the vCenter Server. 

Explanation    Deleted vnic from vCenter Server.

Recommended Action    No action is required.

Error Message     VMS-5-VNIC_OP_FAIL: vnic operation failed on the vCenter Server. 

Explanation    Vnic operation failed on the vCenter Server

Recommended Action    No action is required.

Error Message     VMS-5-VNIC_UPDATE: updated vnic '[chars]' on the vCenter Server. 

Explanation    Updated vnic on vCenter Server.

Recommended Action    No action is required.

VNI Messages

This section contains the VNI messages.

VNI-2

Error Message     VNI-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

VNI-3

Error Message     VNI-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

VNI-6

Error Message     VNI-6-INTERFACE_EVENT: VSAN interface [chars] [chars] 

Explanation    The specified VSAN Interface has been successfully [chars].

Recommended Action    No action is required.

Error Message     VNI-6-STARTING: Virtual Network Interface Manager started 

Explanation    The service has successfully started.

Recommended Action    No action is required.

Error Message     VNI-6-VSAN_DELETED: VSAN [dec] has been deleted 

Explanation    The specified VSAN has been deleted. The service will delete all the configuration on that VSAN.

Recommended Action    No action is required.

VNS_AGENT Messages

This section contains the VNS_AGENT messages.

VNS_AGENT-2

Error Message    VNS_AGENT-2-VNSA_LIC_CRIT: [chars] 

Explanation    VNS License related critical error

Recommended Action    No action is required.

Error Message     VNS_AGENT-2-VNSA_LIC_SLOT_INFO_ERR: Received invalid slot info for 
slot [dec] [[chars]]. May not be able to proceed to checkout vns license. Please 
contact tech support for help.

Explanation    VNS License could not be obtained

Recommended Action    No action is required.

Error Message     VNS_AGENT-2-VNSA_UNLICENSED: VNS license for slot [dec] could not be 
obtained. Please contact your Cisco account team or partner to purchase Licenses. 
To activate your purchased licenses, click on www.cisco.com/go/license.

Explanation    VNS License could not be obtained

Recommended Action    Please contact your sales representative to obtain a license

VNS_AGENT-3

Error Message     VNS_AGENT-3-VPATH_LIC_CFG_ERR: failed to configure license, 
num_of_licenses [dec] module [dec] err [dec]

Explanation    Failed to configure license

Recommended Action    No action is required.

Error Message     VNS_AGENT-3-VPATH_ORG_CFG_ERR: failed to configure org, if_index 
[hex]([hex]) module [dec] oper [dec] err [dec]

Explanation    Failed to configure org

Recommended Action    No action is required.

Error Message     VNS_AGENT-3-VPATH_PORT_CFG_ERR: failed to configure vsn-port, 
if_index [hex]([hex]) vsnindex [dec] module [dec] oper [dec] err [dec]

Explanation    Failed to configure vsn-port

Recommended Action    No action is required.

Error Message     VNS_AGENT-3-VPATH_VSN_CFG_ERR: failed to configure vsn, vlan [dec] ip 
[chars] vsnindex [dec] module [dec] oper [dec] err [dec]

Explanation    Failed to configure vsn

Recommended Action    No action is required.

Error Message     VNS_AGENT-3-VSN_VLAN_DOWN: VSN-VLAN, [dec], specified in 
port-profile, [chars], is down. 

Explanation    VSN VLAN is down

Recommended Action    Please check VLAN status configured in vn-service command

VNS_AGENT-5

Error Message     VNS_AGENT-5-VNSA_CLOCK_CHANGE: Clock setting has been changed on the 
system. Please be aware that clock changes will force a recheckout of all existing 
VNS licenses. During this recheckout procedure, licensed VEMs could lose their VNS 
licenses.

Explanation    Clock setting has been changed on the system. Please be aware that clock changes will force a recheckout of all existing VNS licenses. During this recheckout procedure, licensed VEMs could lose their VNS licenses.

Recommended Action    No action is required.

VNS_AGENT-6

Error Message     VNS_AGENT-6-VNSA_LIC_CHECKIN: VNS licenses for Slot [dec] are being 
checked in. 

Explanation    Licenses are being checked in for the slot

Recommended Action    No action is required.

Error Message     VNS_AGENT-6-VNSA_LIC_RECHECKOUT: VNS licenses for VEM [dec] are being 
rechecked out due to [chars]. 

Explanation    Licenses are being rechecked out from license manager

Recommended Action    No action is required.

VNS_AGENT-7

Error Message     VNS_AGENT-7-VNSA_LIC_DEBUG: [chars] 

Explanation    VNS License related debug info

Recommended Action    No action is required.

VPC Messages

This section contains the VPC messages.

VPC-2

Error Message    VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain [dec], VPC peer keep-alive 
receive has failed 

Explanation    Peer keep-alive receive failed

Recommended Action    No action is required.

Error Message     VPC-2-PEER_KEEP_ALIVE_SEND_FAIL: In domain [dec], VPC peer keep-alive 
send has failed 

Explanation    Peer keep-alive send failed

Recommended Action    No action is required.

Error Message     VPC-2-PEER_VPC_RESP_TIMEDOUT: Failed to receive response from peer 
for vPC: [dec] 

Explanation    VPC bringup failed

Recommended Action    No action is required.

Error Message     VPC-2-TRACK_INTFS_DOWN: In domain [dec], vPC tracked interfaces down, 
suspending all vPCs and keep-alive 

Explanation    VPC tracked object down

Recommended Action    No action is required.

Error Message     VPC-2-VPC_ISSU_END: Peer vPC switch ISSU end, unlocking configuration 

Explanation    Peer vPC switch issu end

Recommended Action    No action is required.

Error Message     VPC-2-VPC_ISSU_START: Peer vPC switch ISSU start, locking 
configuration 

Explanation    Peer vPC switch issu start

Recommended Action    No action is required.

Error Message     VPC-2-VPC_LC_FAIL: LC [dec] does not support required hardware for 
vPC; run 'show vdc membership status' for port status 

Explanation    Lc insertion failed

Recommended Action    No action is required.

Error Message     VPC-2-VPC_SUSP_ALL_VPC: Peer-link going down, suspending all vPCs on 
secondary 

Explanation    Peer link down suspend vPCs

Recommended Action    No action is required.

Error Message     VPC-2-VPC_SVI_EXCLUDE: vPC [dec] has up vlans [chars] which are 
excluded from suspension on dual-active 

Explanation    VPC track object deconfigured

Recommended Action    No action is required.

VPC-3

Error Message     VPC-3-GLOBAL_CONSISTENCY_FAILED: In domain [dec], global 
configuration is not consistent ([chars]) 

Explanation    Global compat-check failed

Recommended Action    No action is required.

Error Message     VPC-3-INTF_CONSISTENCY_FAILED: In domain [dec], VPC [dec] 
configuration is not consistent ([chars]) 

Explanation    MCEC compat-check failed

Recommended Action    No action is required.

Error Message     VPC-3-PEER_UNREACHABLE: Remote Switch Unreachable 

Explanation    Peer unreachable

Recommended Action    No action is required.

Error Message     VPC-3-PEER_VPC_BRINGUP_FAILED: Peer vPC [dec] bringup failed 
([chars]) 

Explanation    Peer vPC bringup failed

Recommended Action    No action is required.

Error Message     VPC-3-VPCM_ASSERTION_FAILED: [chars] 

Explanation    VPCM has hit an assert condition at file [chars]

Recommended Action    No action is required.

Error Message     VPC-3-VPCM_INIT_FAIL: vPC Manager Initialization Failed ([chars]) 

Explanation    VPCM Initialization failed. due to [chars]

Recommended Action    No action is required.

Error Message     VPC-3-VPCM_INTERNAL_ERR: [chars] 

Explanation    VPCM encountered an internal error due to [chars]

Recommended Action    No action is required.

Error Message     VPC-3-VPCM_MTS_ERR: [chars] 

Explanation    VPCM encountered an MTS error due to [chars]

Recommended Action    No action is required.

Error Message     VPC-3-VPC_BRINGUP_FAILED: vPC [dec] bringup failed ([chars]) 

Explanation    VPC bringup failed

Recommended Action    No action is required.

Error Message     VPC-3-VPC_PEER_LINK_BRINGUP_FAILED: vPC peer-link bringup failed 
([chars]) 

Explanation    VPC Peer-link bringup failed

Recommended Action    No action is required.

Error Message     VPC-3-VPC_PEER_LINK_DOWN: VPC Peer-link is down ([chars]) 

Explanation    VPC Peer link is down (reason)

Recommended Action    No action is required.

VPC-4

Error Message     VPC-4-PEER_VPC_DELETED: Peer vPC [dec] deleted 

Explanation    Peer vPC configuration deleted

Recommended Action    No action is required.

Error Message     VPC-4-VPC_DELETED: vPC [dec] is deleted 

Explanation    VPC configuration deleted

Recommended Action    No action is required.

Error Message     VPC-4-VPC_PEER_LINK_DELETED: vPC Peer-link deleted. This will 
bringdown all vPC interfaces 

Explanation    VPC Peer-link configuration removed

Recommended Action    No action is required.

Error Message     VPC-4-VPC_PEER_ROLE_CHANGE: In domain [dec], VPC peer role status has 
changed to [chars] 

Explanation    VPC Peer role status changed to (Primary/Secondary

Recommended Action    No action is required.

Error Message     VPC-4-VPC_ROLE_CHANGE: In domain [dec], VPC role status has changed 
to [chars] 

Explanation    VPC role status changed to (Primary/Secondary

Recommended Action    No action is required.

VPC-5

Error Message     VPC-5-GLOBAL_CONSISTENCY_SUCCESS: Global configuration for vPC domain 
[dec] is consistent 

Explanation    Global compat-check passed

Recommended Action    No action is required.

Error Message     VPC-5-INTF_CONSISTENCY_SUCCESS: In domain [dec], vPC [dec] 
configuration is consistent 

Explanation    VPC configuration is consistent

Recommended Action    No action is required.

Error Message     VPC-5-PEER_KEEP_ALIVE_STATUS: In domain [dec], peer keep-alive status 
changed to [chars] 

Explanation    Peer keep-alive (oob) status is changed to <peer-alive

Recommended Action    Peer-not-alive

Error Message     VPC-5-VPCM_DISABLED: vPC Manager disabled 

Explanation    VPCM Service Disabled

Recommended Action    No action is required.

Error Message     VPC-5-VPCM_ENABLED: vPC Manager enabled 

Explanation    VPCM Service Enabled

Recommended Action    No action is required.

Error Message     VPC-5-VPC_RESTORE_TIMER_EXPIRED: vPC restore timer expired, reiniting 
vPCs 

Explanation    VPC restore timer expired

Recommended Action    No action is required.

Error Message     VPC-5-VPC_RESTORE_TIMER_START: vPC restore timer started to reinit 
vPCs 

Explanation    VPC restore timer start

Recommended Action    No action is required.

Error Message     VPC-5-VPC_ROLE_PREMPT: In domain [dec], vPC role pre-emption 
triggered 

Explanation    VPC preemption triggered

Recommended Action    No action is required.

VPC-6

Error Message     VPC-6-PEER_KEEP_ALIVE_RCV_INT_CHANGED: In domain [dec], VPC 
peer-keepalive received on interface [chars] 

Explanation    VPC peer-keepalive receive interface changed

Recommended Action    No action is required.

Error Message     VPC-6-PEER_KEEP_ALIVE_RECV_SUCCESS: In domain [dec], vPC peer 
keep-alive receive is successful 

Explanation    Peer keep-alive receive successful

Recommended Action    No action is required.

Error Message     VPC-6-PEER_KEEP_ALIVE_SEND_INT_CHANGED: In domain [dec], VPC 
peer-keepalive sent on interface [chars] 

Explanation    VPC peer-keepalive send interface changed

Recommended Action    No action is required.

Error Message     VPC-6-PEER_KEEP_ALIVE_SEND_SUCCESS: In domain [dec], vPC peer 
keep-alive send is successful 

Explanation    Peer keep-alive send successful

Recommended Action    No action is required.

Error Message     VPC-6-PEER_LOCK_FAILED: Locking failed on peer switch - Aborting 
upgrade!! 

Explanation    Locking failed on peer switch

Recommended Action    No action is required.

Error Message     VPC-6-PEER_VPC_CFGD_VLANS_CHANGED: Peer vPC [dec] configured vlans 
changed 

Explanation    Remote MCEC configured vlans Changed

Recommended Action    No action is required.

Error Message     VPC-6-PEER_VPC_CFGD: peer vPC [dec] is configured 

Explanation    VPC is configured

Recommended Action    No action is required.

Error Message     VPC-6-PEER_VPC_DOWN: Peer vPC [dec] is down ([chars]) 

Explanation    Peer vPC is down

Recommended Action    No action is required.

Error Message     VPC-6-PEER_VPC_UP: Peer vPC [dec] is up 

Explanation    Peer vPC is up

Recommended Action    No action is required.

Error Message     VPC-6-ROLE_PRIORITY_CFGD: In domain [dec], vPC role priority changed 
to [dec] 

Explanation    Role priority configured

Recommended Action    No action is required.

Error Message     VPC-6-STATS_CLEARED: vPC Statistics Cleared 

Explanation    VPC statistics cleared

Recommended Action    No action is required.

Error Message     VPC-6-SYSTEM_MAC_CFGD: In domain [dec], vPC system-mac changed to 
[chars] 

Explanation    System mac configured

Recommended Action    No action is required.

Error Message     VPC-6-SYSTEM_PRIO_CFGD: In domain [dec], vPC system priority changed 
to [dec] 

Explanation    System priority changed

Recommended Action    No action is required.

Error Message     VPC-6-TRACK_OBJ_CONFIGURED: In domain [dec], track object configured 
[dec] 

Explanation    VPC track object configured

Recommended Action    No action is required.

Error Message     VPC-6-TRACK_OBJ_DELETED: In domain [dec], track object deleted 

Explanation    VPC track object deconfigured

Recommended Action    No action is required.

Error Message     VPC-6-TYPE1_PARAM_CHANGED: TYPE-1 parameters changed: [chars] 

Explanation    Type-1 Parameters Changed

Recommended Action    No action is required.

Error Message     VPC-6-VPCM_INTERNAL_INFO: [chars] 

Explanation    VPCM got an internal info [chars]

Recommended Action    No action is required.

Error Message     VPC-6-VPC_ALLOWED_VLAN_CHANGED: vPC [dec] operational vlans changed 

Explanation    Operational vlans changed on vPC

Recommended Action    No action is required.

Error Message     VPC-6-VPC_CFGD: vPC [dec] is configured 

Explanation    VPC is configured

Recommended Action    No action is required.

Error Message     VPC-6-VPC_DOMAIN_ID_CFGD: vPC domain-id configured to [dec] 

Explanation    VPC domain-id configured

Recommended Action    No action is required.

Error Message     VPC-6-VPC_DOWN: vPC [dec] is down ([chars]) 

Explanation    VPC is down (reason)

Recommended Action    No action is required.

Error Message     VPC-6-VPC_PEER_LINK_CFGD: vPC peer-link is configured 

Explanation    VPC Peer-link is configured

Recommended Action    No action is required.

Error Message     VPC-6-VPC_PEER_LINK_UP: vPC Peer-link is up 

Explanation    VPC Peer-link is up

Recommended Action    No action is required.

Error Message     VPC-6-VPC_UP: vPC [dec] is up 

Explanation    MCEC is UP

Recommended Action    No action is required.

VPM Messages

This section contains the VPM messages.

VPM-2

Error Message    VPM-2-GENERAL_ERROR: [chars] 

Explanation    The VP Manager has encountered an critical error. The description of error is [str.]

Recommended Action    No action is required.

Error Message     VPM-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The VP Manager could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     VPM-2-PSS_ERROR: [chars] 

Explanation    The VP Manager encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     VPM-2-VPMON_CRIT: [chars] [dec] 

Explanation    VPMON daemon critical message

Recommended Action    No action is required.

Error Message     VPM-2-VPMON_DPP_DOWNLOAD: HB failure, Restarting the DPP [dec] 

Explanation    VPMON daemon redownloading DPP(s)

Recommended Action    ISAPI API users need to re-download config data to fast path

Error Message     VPM-2-VPMON_DPP_RELOAD_FORCE: Force reload of DPP(s) [chars]: [chars] 

Explanation    VPMON daemon critical action message

Recommended Action    No action is required.

VPM-3

Error Message     VPM-3-PSS_SYNC_TO_STNDBY_FAILED: PSS TYPE=[chars] KEY=[chars] 

Explanation    Could not send PSS Sync. notification to Standby Supervisor. PSS Type=[str.] Operation=[.str] Key=[Str.]

Recommended Action    No action is required.

Error Message     VPM-3-SEND_TO_ILC_FAILED: [chars] 

Explanation    The VP Manager could not send to ILC for DG=[chars], at slot=[dec] processor=[dec] and SAP=[dec].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     VPM-3-SEND_TO_SNMP_AGENT_FAILED: [chars] 

Explanation    The VP Manager could not send to SNMP Agent for DG=[chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     VPM-3-UNKNOWN_MSG: Recvd. from Node=[dec] SAP=[dec] 

Explanation    The VP Manager has received an unknown message from [dec]].[dec]. This information is for debugging only.

Recommended Action    No action is required.

Error Message     VPM-3-VPM_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The VP Manager has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

VPM-4

Error Message     VPM-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the VP Manager and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

VPM-6

Error Message     VPM-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The VP Manager on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     VPM-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The VP Manager became standby from active mode.

Recommended Action    No action is required.

Error Message     VPM-6-DG_DEREGISTERED: [chars] 

Explanation    The VP Manager has deregistered DG [chars] at slot=[dec] processor=[dec] and SAP=[dec].

Recommended Action    No action is required.

Error Message     VPM-6-DG_REGISTERED: [chars] 

Explanation    The VP Manager has registered DG [chars] from slot=[dec] processor=[dec] and SAP=[dec].

Recommended Action    No action is required.

Error Message     VPM-6-EXITING: Exited due to [chars] 

Explanation    The VP Manager process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     VPM-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The VP Manager was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     VPM-6-GENERAL_EVENT: [chars] 

Explanation    The VP Manager has generated an important event. The description of the event is [str.]

Recommended Action    No action is required.

Error Message     VPM-6-PSS_CREATED: [chars] PSS Created 

Explanation    One of the persistent information database of VP Manager has been recreated

Recommended Action    No action is required.

Error Message     VPM-6-PSS_DESTROYED: [chars] PSS Destroyed 

Explanation    One of the persistent information databases of Vp Manager has been intentionally destroyed and would be recreated.

Recommended Action    No action is required.

Error Message     VPM-6-SERVICE_UP: Initialized [chars] 

Explanation    The VP Manager is up and ready to accept client requests The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     VPM-6-SWITCHOVER: Switching Over to other Sup. 

Explanation    The VP Manager has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

Error Message     VPM-6-VPMON_INFO: [chars] 

Explanation    VPMON daemon informational message

Recommended Action    No action is required.

Error Message     VPM-6-VPMON_STARTING: deamon started 

Explanation    The VPMON daemon successfully started

Recommended Action    No action is required.

Error Message     VPM-6-VPM_MDS_LICENSE_GRACE: MDS LICENSE in grace period for feature 
: [chars] 

Explanation    MDS license is in grace period. Please retrieve a new MDS license

Recommended Action    No action is required.

Error Message     VPM-6-VPM_MDS_LICENSE_REVOKED: MDS LICENSE REVOKED for feature : 
[chars] 

Explanation    MDS license is revoked. Please retrieve a new MDS license

Recommended Action    No action is required.

Error Message     VPM-6-VPM_MDS_TIMED_LICENSE: Timed MDS LICENSE for feature : [chars] 

Explanation    Timed MDS license

Recommended Action    No action is required.

VPM-SLOT#-2

Error Message     VPM-SLOT#-2-CPP_CATASTROPHIC_ERROR: ERROR: Component ([chars]) caused 
critical error please reboot SSM 

Explanation    Component caused critical error

Recommended Action    Restart the linecard

VRRP-CFG Messages

This section contains the VRRP-CFG messages.

VRRP-CFG-2

Error Message    VRRP-CFG-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

Error Message     VRRP-CFG-2-VSH_REGISTER_FAIL: VSH registration failed returning [dec] 

Explanation    VRRP's parse tree registration with VSH failed

Recommended Action    No action is required.

VRRP-CFG-3

Error Message     VRRP-CFG-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

Error Message     VRRP-CFG-3-VRRP_FEATURE_MANAGER_ERROR: Error in feature manager 
operation 

Explanation    The feature manager operation did not go through fine

Recommended Action    Please check the reason for error using feature manager and rectify the problem

VRRP-CFG-5

Error Message     VRRP-CFG-5-STARTING: VRRP Manager service started 

Explanation    The service successfully started.

Recommended Action    No action is required.

VRRP-ENG Messages

This section contains the VRRP-ENG messages.

VRRP-ENG-2

Error Message    VRRP-ENG-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

Error Message     VRRP-ENG-2-INVALID_CONFIG: Cannot start the VR[chars] [dec] on the 
interface [chars]. Invalid IP configuration. Reason: [chars]

Explanation    The specified VR on interface [chars] is enabled but the IP configuration is not valid because of [chars].

Recommended Action    Show interface to check that the IP address of the interface is configured and it is in the same subnet of the virtual router address.

Error Message     VRRP-ENG-2-VR_FAILURE: Error in VR[chars] [dec] interface [chars]. 
Going to init state 

Explanation    The VR [dec] on the interface [chars] is in init state for an internal error.

Recommended Action    Show interface to check the status of the interface, show configuration, status and statistics of the specified virtual router, enable the vrrp debug and shut/ no shut the specified virtual router.

VRRP-ENG-3

Error Message     VRRP-ENG-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

VRRP-ENG-4

Error Message     VRRP-ENG-4-BAD_ADV: VR[chars] ID [dec] on interface [chars] bad 
advertisement received: reason [chars]

Explanation    The virtual router specified has received an invalid advertisement.

Recommended Action    Check that all VRRP nodes have the same configuration.

VRRP-ENG-5

Error Message     VRRP-ENG-5-INTERFACE_DOWN: Cannot start the VR[chars] [dec] since the 
interface [chars] is down 

Explanation    The specified VR is enabled but can't change state from init. The specified interface is down or doesn't have a primary IP address configured.

Recommended Action    No action is required.

Error Message     VRRP-ENG-5-INTERFACE_STATE_CHANGE: Interface [chars] state changed to 
[chars] 

Explanation    The interface specified has changed state This could have triggered a VRRP status change.

Recommended Action    No action is required.

Error Message     VRRP-ENG-5-STARTING: VRRP Engine service started 

Explanation    The service successfully started.

Recommended Action    No action is required.

Error Message     VRRP-ENG-5-VR_STATE_CHANGE: VR[chars] ID [dec] on interface [chars] 
state changed to [chars] 

Explanation    The status of the specified virtual router has changed to [chars].

Recommended Action    No action is required.

VRRP-ENG-6

Error Message     VRRP-ENG-6-VSHA_RESULT: VR ID [dec] on interface [chars] state change 
request result [chars]

Explanation    The result of the request for status change on the virtual router (with VSHA extension) specified is [chars].

Recommended Action    No action is required.

VSAN Messages

This section contains the VSAN messages.

VSAN-2

Error Message    VSAN-2-PROGRAM_EXIT: process exiting with reason: [chars] 

Explanation    VSAN manager process is exiting with reason [chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

VSAN-3

Error Message     VSAN-3-CFS_OPERATION_FAILED: cfs [chars] operation failed : [chars] 

Explanation    Cfs operation [chars1] has failed. [chars2]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     VSAN-3-MEM_ALLOC_FAILED: alloc failed for size:[dec] 

Explanation    Memory allocation of size [dec] failed.

Recommended Action    Do show process memory command to see memory usage of processes.

Error Message     VSAN-3-MESSAGE_ERROR: could not handle message:[chars] of type [dec] 
sent by addr [dec]:[dec] 

Explanation    Got an IPC message [chars] of type [dec1] sent by a component running on node [dec2] with sap [dec3].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

VSAN-6

Error Message     VSAN-6-ACTIVATED: VSAN:[dec] changing from suspended to active 

Explanation    Making VSAN with ID [dec] active from suspended state.

Recommended Action    No action is required.

Error Message     VSAN-6-CFS_MERGE_NOT_SUPPORTED: merging of fctimer configuration data 
is not supported 

Explanation    Merging of fctimer configuration data using cfs is not supported

Recommended Action    No action is required.

Error Message     VSAN-6-CREATED: Created VSAN:[dec] with name:[chars] 

Explanation    Created VSAN with ID [dec] and name [chars].

Recommended Action    No action is required.

Error Message     VSAN-6-MEMBERSHIP_UPDATE: Updated membership for interface:[chars] 
with VSAN:[dec] 

Explanation    Updating membership for interface [chars] with VSAN [dec].

Recommended Action    No action is required.

Error Message     VSAN-6-REMOVED: Removed VSAN:[dec] 

Explanation    Removed VSAN with ID [dec].

Recommended Action    No action is required.

Error Message     VSAN-6-SUSPENDED: VSAN:[dec] changing from active to suspended 

Explanation    Suspending VSAN with ID [dec] from active state.

Recommended Action    No action is required.

Error Message     VSAN-6-TRUNKING_MEMBERSHIP_UPDATE: trunking membership updated for 
interface:[chars] with VSAN bitmap:[chars] 

Explanation    Updated trunking membership for interface [chars1] with allowed VSAN list [chars2].

Recommended Action    No action is required.

VSD Messages

This section contains the VSD messages.

VSD-SLOT#-2

Error Message    VSD-SLOT#-2-CPP_CATASTROPHIC_ERROR: ERROR: Component ([chars]) caused 
critical error please reboot SSM 

Explanation    Component caused critical error

Recommended Action    Restart the linecard

VSHD Messages

This section contains the VSHD messages.

VSHD-2

Error Message    VSHD-2-VSHD_ROLE_DATABASE_TOO_LARGE: Role database too large. Unable 
to add RBAC entry 

Explanation    There are too many rules and policies configured causing the entire role database too exceed 120KB

Recommended Action    Please delete some rules, policies, or roles and try to better optimize the RBAC database

Error Message     VSHD-2-VSHD_SYSLOG_EOL_ERR: EOL function [chars] from library [chars] 
exited due to Signal [dec] 

Explanation    Error in CLI EOL function

Recommended Action    No action is required.

Error Message     VSHD-2-VSHD_SYSLOG_PSS_SNAPSHOT_ERR: Source URI:[chars] Destination 
URI:[chars] errcode:[dec] 

Explanation    PSS snapshot error

Recommended Action    No action is required.

Error Message     VSHD-2-VSHD_SYSLOG_SDWRAP_ERR: Description:[chars] errcode:[dec] 

Explanation    Debug infrastructure error

Recommended Action    No action is required.

VSHD-3

Error Message     VSHD-3-VSHD_ROLE_DISTRIBUTE_FAILURE: Role distribution operation 
([chars]) failed with error id [hex] 

Explanation    This is probably occurring due to unstable fabric

Recommended Action    Please retry operation when fabric is stable

Error Message     VSHD-3-VSHD_SYSLOG_FILE_ERR: Purpose:[chars] Filename:[chars] 
errcode:[dec] 

Explanation    File handling error

Recommended Action    No action is required.

Error Message     VSHD-3-VSHD_SYSLOG_MTS_ERR: message [chars] 

Explanation    MTS message handling error

Recommended Action    No action is required.

Error Message     VSHD-3-VSHD_SYSLOG_PARSE_TREE_ERR: [chars] 

Explanation    Error while updating parse tree in shell

Recommended Action    No action is required.

Error Message     VSHD-3-VSHD_SYSLOG_PSS_ERR: Purpose:[chars] URI:[chars] 
errcode:[dec] 

Explanation    PSS handling error

Recommended Action    No action is required.

VSHD-4

Error Message     VSHD-4-VSHD_LICENSE_EXPIRY_WARNING: License [chars] expires on 
[chars]. Vsan policy will be set to default (deny) for all roles when license 
expires

Explanation    Vsan policy would be set default (deny) for all roles when license expires

Recommended Action    Please install the license file to continue using the feature.

Error Message     VSHD-4-VSHD_ROLE_DATABASE_OUT_OF_SYNC: Role configuration database 
found to be different between the switches during merge

Explanation    Role configuration database is recommended to be identical among all switches in the fabric.

Recommended Action    Edit the configuration on one of the switches to obtain the desired role configuration database and then commit it

Error Message     VSHD-4-VSHD_ROLE_DATABASE_VERSION_NOT_UNDERSTOOD: This switch does 
not understand the version of role configuration database received during merge

Explanation    This is probably occurring due to different versions of system image on switches in the fabric

Recommended Action    Please make sure all switches are running the same version of the system image

VSHD-5

Error Message     VSHD-5-VSHD_SYSLOG_CONFIG_CHANGE: VDC=[chars], VTY=[chars], 
user=[chars], CMD=[chars]

Explanation    Configuration change notification

Recommended Action    No action is required.

Error Message     VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by [chars] on 
[chars] 

Explanation    CLI Configuration mode was exited

Recommended Action    No action is required.

Error Message     VSHD-5-VSHD_SYSLOG_ROLE_CREATED: New cli role [chars] created 

Explanation    New cli role created

Recommended Action    No action is required.

VSHD-7

Error Message     VSHD-7-VSHD_SYSLOG_PARSE_TREE_UPDATE: Parse tree [chars] 

Explanation    Parse tree updated in shell

Recommended Action    No action is required.

WWN Messages

This section contains the WWN messages.

WWN-1

Error Message    WWN-1-TYPE1_ALERT: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has run out of WWNs. No new dynamically allocated WWNs are available. However, statically assigned WWNs such as switch WWN, port WWN, etc. are still available.

Recommended Action    Please add additional WWNs by programming a new Secondary MAC address and its range.

Error Message     WWN-1-TYPES2_5_ALERT: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has run out of WWNs of NAA Types 2 and 5

Recommended Action    Please add additional WWNs by programming a new Secondary MAC address and its range.

WWN-2

Error Message     WWN-2-BKPLN_PROM_CANT_READ: Can not read backplane PROM 

Explanation    The WWN Manager has failed to read chassis information. No dynamic WWNs could be allocated.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     WWN-2-EXITING: Exited due to [chars] 

Explanation    The WWN Manager process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     WWN-2-GENERAL_ERROR: [chars] 

Explanation    The WWN Manager has encountered an critical error. The description of error is [str.].

Recommended Action    No action is required.

Error Message     WWN-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The WWN Manager could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     WWN-2-PSS_BKP_PSS_MISMATCH: Block [dec]: PSS: Not Free; BKPLN PROM: 
Free 

Explanation    This WWN Manager detected a discrepancy between the information on the chassis and that in its persistent information databases. The persistent information database has been updated with the information on the chassis.

Recommended Action    No action is required.

Error Message     WWN-2-PSS_ERROR: [chars] 

Explanation    The WWN Manager encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     WWN-2-STDOUT_ROTATE_FAILURE: Failed to rotate stdout file: [chars] 

Explanation    The WWN Manager has failed to rotate its current stdout file with filename [str.]. The filesize could grow beyond its maximum limit.

Recommended Action    No action is required.

Error Message     WWN-2-TYPE1_CRIT: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has only [dec] or less than [dec]-percent WWNs remaining.

Recommended Action    Please add additional WWNs by programming a new Secondary MAC address and its range.

Error Message     WWN-2-TYPES2_5_CRIT: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has only [dec] or less than [dec]-percent WWNs of NAA Types 2 and 5 remaining.

Recommended Action    Please add additional WWNs by programming a new Secondary MAC address and its range.

WWN-3

Error Message     WWN-3-PSS_SYNC_TO_STNDBY_FAILED: PSS TYPE=[chars] KEY=[chars] 

Explanation    Could not send PSS Sync. notification to Standby Supervisor. PSS Type=[str.] Operation=[.str] Key=[Str.].

Recommended Action    No action is required.

Error Message     WWN-3-RELEASE_ERR_UNKNOWN: Unknown WWN [chars] [chars] 

Explanation    WWN Manager received a request to release a WWN [char] that could not have been allocated by this WWN Manager due to [char].

Recommended Action    No action is required.

Error Message     WWN-3-RELEASE_ERR: Cant Rel. WWN [chars] 

Explanation    WWN Manager received a request to release a WWN that cannot be released.

Recommended Action    No action is required.

Error Message     WWN-3-STARTUP_COPY_TO_RUNNING_FAILED: [chars] 

Explanation    Could not snapshot Startup-Config PSS to Running-Config. The description of error is [str.].

Recommended Action    No action is required.

Error Message     WWN-3-TOOMANY_REQ_REL: WWNs [chars] = [dec] > MAX LIMIT 1024 - Denied 

Explanation    The WWN Manager received a request to allocate [dec] WWN, which is more than the maximum number of WWNs that can be allocated/released in a single request.

Recommended Action    No action is required.

Error Message     WWN-3-UNKNOWN_MSG: Received from Node=[dec] SAP=[dec] Opcode=[dec] 

Explanation    The WWN Manager has received an unknown message from [dec]].[dec] with opcode [dec]. This information is for debugging only.

Recommended Action    No action is required.

Error Message     WWN-3-WWN_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The WWN Manager has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

WWN-4

Error Message     WWN-4-PSS_SUP_CNT_MISMATCH: PSS [dec] Bkpln [dec] 

Explanation    The WWN Manager has detected that some other supervisor card was plugged in earlier on this chassis. This WWN Manager is making sure that new WWNs allocate do not conflict with WWNs that could have been allocated by the previous supervisor card.

Recommended Action    No action is required.

Error Message     WWN-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the WWN Manager and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

Error Message     WWN-4-TYPE1_WARN: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has only [dec] or less than [dec]-percent WWNs remaining for allocation.

Recommended Action    No action is required.

Error Message     WWN-4-TYPES2_5_WARN: [dec] (< [dec] %) Remain 

Explanation    The WWN Manager has only [dec] or less than [dec]-percent WWNs of NAA Types 2 and 5 remaining.

Recommended Action    Please add additional WWNs by programming a new Secondary MAC address and its range.

WWN-5

Error Message     WWN-5-VSAN_WWN_CHANGE: [chars] 

Explanation    VSAN-WWN created or deleted. The description of error is [str.].

Recommended Action    No action is required.

WWN-6

Error Message     WWN-6-ALLOCATED_BLOCK: Block number [dec] 

Explanation    The WWN Manager has allocated a new block, block number [dec], of 256 WWNs for internal use.

Recommended Action    No action is required.

Error Message     WWN-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The WWN Manager on the standby supervisor became active and it is ready to serve client requests for WWNs.

Recommended Action    No action is required.

Error Message     WWN-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The WWN Manager became standby from active mode.

Recommended Action    No action is required.

Error Message     WWN-6-EXCESSIVE_DELAY: [chars] 

Explanation    Excessive time taken for a processing event. The description of the event is [str.].

Recommended Action    No action is required.

Error Message     WWN-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The WWN Manager was unable to send heartbeat to the system manager.

Recommended Action    No action is required.

Error Message     WWN-6-GENERAL_EVENT: [chars] 

Explanation    The WWN Manager has generated an important event. The description of the event is [str.].

Recommended Action    No action is required.

Error Message     WWN-6-PSS_CREATED: [chars] PSS Created 

Explanation    One of the persistent information database of the WWN Manager has been recreated.

Recommended Action    No action is required.

Error Message     WWN-6-PSS_DESTROYED: [chars] PSS Destroyed 

Explanation    One of the persistent information databases has been intentionally destroyed and would be recreated.

Recommended Action    No action is required.

Error Message     WWN-6-RELEASED_BLOCK: Block number [dec] 

Explanation    The WWN Manager has released a block, block number [dec], of 256 WWNs.

Recommended Action    No action is required.

Error Message     WWN-6-SEC_MAC_UPDATED: MAC=[chars] Range=[dec] 

Explanation    The WWN Manager had updated the Secondary MAC address with MAC address [char] and range [dec]. This update was initiated from a management entity.

Recommended Action    No action is required.

Error Message     WWN-6-SERVICE_UP: Initialized [chars] 

Explanation    The WWN Manager is up and ready to accept client requests for WWNs. The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     WWN-6-SWITCHOVER: Switching Over to other Supervisor 

Explanation    The WWN Manager has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

WWN-7

Error Message     WWN-7-RELEASE_ERR_FREE: Already free WWN [chars] 

Explanation    A client of WWN Manager attempted to release WWN [char] which is already free. This information is for debugging only.

Recommended Action    No action is required.

XBAR_CLIENT Messages

This section contains the XBAR_CLIENT messages.

XBAR_CLIENT-2

Error Message    XBAR_CLIENT-2-MEM_FULL: memory allocation failed 

Explanation    Process xbar_client failed to allocate memory

Recommended Action    Please examine the xbar-client event-history for more information.

Error Message     XBAR_CLIENT-2-PROC_DN: exiting: [chars]. 

Explanation    Process xbar_client is exiting

Recommended Action    Please examine the xbar-client event-history for more information.

Error Message     XBAR_CLIENT-2-PROC_INITFAIL: Process initialization failed due to 
[chars]. 

Explanation    XBAR_CLIENT process has failed initialization.

Recommended Action    Please perform a 'show xbar-client event-history' to collect more information.

Error Message     XBAR_CLIENT-2-PROC_INITFAIL: initialization failed due to [chars] 

Explanation    Process xbar_client failed initialization

Recommended Action    Please examine the xbar-client event-history for more information.

XBAR_CLIENT-3

Error Message     XBAR_CLIENT-3-IPC_MSGERR: failure processing IPC message [dec], error 
code = [dec] 

Explanation    Process xbar_client failed to process IPC message

Recommended Action    Please examine the xbar-client event-history for more information.

Error Message     XBAR_CLIENT-3-IPC_MSGUNKN: unknown IPC message received: [dec] 

Explanation    Process xbar_client has received an unknown IPC message.

Recommended Action    Please examine the xbar-client event-history for more information.

XBAR_CLIENT-SLOT#-2

Error Message     XBAR_CLIENT-SLOT#-2-VEGAS2_XBC_MEM_FULL: memory allocation failed in 
routine [chars] 

Explanation    Process xbar_client failed to allocate memory

Recommended Action    Please perform a 'show process xbar-client event-history' to collect more information

Error Message     XBAR_CLIENT-SLOT#-2-VEGAS2_XBC_PROC_DN: terminating due to signal 
[dec] 

Explanation    Process xbar_client is exiting

Recommended Action    Please perform a 'show process xbar-client event-history' to collect more information

Error Message     XBAR_CLIENT-SLOT#-2-VEGAS2_XBC_PROC_INITFAIL: initialization failed: 
syserr [dec], errno [dec] 

Explanation    Process xbar_client failed initialization

Recommended Action    Please perform a 'show process xbar-client event-history' to collect more information

XBAR_CLIENT-SLOT#-3

Error Message     XBAR_CLIENT-SLOT#-3-VEGAS2_XBC_IPC_MSGUNKN: unknown IPC message 
received: opcode [dec] 

Explanation    Process xbar_client hass received an unknown IPC message

Recommended Action    Please perform a 'show process xbar-client event-history' to collect more information

XBAR Messages

This section contains the XBAR messages.

XBAR-2

Error Message    XBAR-2-ARB_INIT_FAIL: Arbiter Initialization failed return_code [hex] 
([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-2-INCOMPATIBLE_CONFIG: [chars] [dec] [chars]. 

Explanation    This module is not compatible with the current fabric mode. It will be powered down.

Recommended Action    No action is required.

Error Message     XBAR-2-XBAR_INSUFFICIENT_XBAR_BANDWIDTH: Module in slot [dec] has 
insufficient xbar-bandwidth. 

Explanation    To track insufficient xbar-bandwidth.

Recommended Action    No action is required.

Error Message     XBAR-2-XBAR_SUFFICIENT_XBAR_BANDWIDTH: Module in slot [dec] has 
sufficient xbar-bandwidth. 

Explanation    To track recovery from insufficient xbar-bandwidth.

Recommended Action    No action is required.

XBAR-3

Error Message     XBAR-3-MEM_FULL: Memory allocation failed. [chars] %i 

Explanation    The system has detected an error.

Recommended Action    No action is required.

XBAR-5

Error Message     XBAR-5-ARBITER_INIT_FAILURE: Re-initializing Arbiter. [chars] [chars] 
module %i 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_CLEAR_PORT_FAIL: Arbiter reported failure to de-register 
port [dec] in group [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_MOD_DIS_INTR_FAIL: Arbiter reported failure to 
disable interrupt for module [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_MOD_INSERT_CHECK_FAIL: Arbiter reported failure to 
recognize module [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_MOD_INSERT_FAIL: Arbiter reported failure to init 
module [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_MOD_INTR_FAIL: Arbiter reported failure to enable 
interrupt for module [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_MOD_REMOVE_FAIL: Arbiter reported failure to remove 
module [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-ARB_INIT_PORT_FAIL: Arbiter reported failure to register port 
[dec] in group [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an arbiter setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-MOD_CONNECTION_REATTEMPT: Re-attempting XBAR connection with 
module [dec] 

Explanation    The module has experienced a setup failure on connecting the module to the fabric.

Recommended Action    Collect more informations about XBAR component Use command 'show xbar internal event-history module <module id>'. Power cycling the module may recover.

Error Message     XBAR-5-XBAR_ENABLE_FPOE_DB_FAILURE: XBAR [chars] enabling FPOE-DB 
mode failed 

Explanation    The supervisor failed to enable FPOE-DB mode in fabric. The supervisor is going to reboot. In case of dual supervisor, a switchover will occur.

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_INIT_FAILURE: XBAR [chars] initialization failed [chars] 
%i 

Explanation    The supervisor has experienced a fabric initialization failure. The supervisor is going to reboot. In case of dual supervisor, a switchover will occur.

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_INIT_FAIL: Xbar [[dec].[dec]] reported failure durinig 
intialization return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_CHECK_SYNC_FAIL: Xbar [[dec].[dec]] reported failure 
to check sync on port [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_CONTINUE_SYNC_FAIL: Xbar [[dec].[dec]] reported 
failure to continue sync on port [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_DISABLE_FAIL: Xbar [[dec].[dec]] reported failure to 
disable port [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_ENABLE_FAIL: Xbar [[dec].[dec]] reported failure to 
enable port [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_FORCE_POE_DISABLE_FAIL: Xbar [[dec].[dec]] reported 
failure to disable force poe mode on [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_FORCE_POE_ENABLE_FAIL: Xbar [[dec].[dec]] reported 
failure to enable force poe mode on [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_LPBACK_DISABLE_FAIL: Xbar [[dec].[dec]] reported 
failure to disable port loopback on [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_LPBACK_ENABLE_FAIL: Xbar [[dec].[dec]] reported 
failure to enable port loopback on [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_PORT_START_SYNC_FAIL: Xbar [[dec].[dec]] reported failure 
to start sync on port [dec] return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_RELEASE_ACCESS_FAIL: Slot [dec] reported failure 
releasing [chars] xbar access return_code [hex] ([chars]) 

Explanation    The supervisor has experienced an xbar access failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_SET_ACCESS_FAIL: Slot [dec] reported failure acquiring 
[chars] xbar access return_code [hex] ([chars]) 

Explanation    The supervisor has experienced an xbar access failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_STANDBY_SUP_ARB_FAIL: [chars] return_code [hex] ([chars]) 

Explanation    The supervisor has experienced an arbiter access failure .

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_STATUS_REPORT: Module [dec] reported status for component 
[dec] code [hex]. 

Explanation    An error status has been reported. If error is on supervisor, the supervisor is going to reboot. In case of dual supervisors, a switchover will occur. If error is on module, the module will be power cycled.

Recommended Action    No action is required.

Error Message     XBAR-5-XBAR_SW_INIT_FAIL: Xbar [[dec].[dec]] reported failure durinig 
sw intialization return_code [hex] ([chars]). 

Explanation    The supervisor has experienced an xbar setup failure .

Recommended Action    No action is required.

XMLMA Messages

This section contains the XMLMA messages.

XMLMA-2

Error Message    XMLMA-2-HEARTBEAT_FAIL: XML master agent failed to send heart beat: 
[chars] 

Explanation    XML master agent has failed sending heartbeat.

Recommended Action    No action is required.

Error Message     XMLMA-2-INITFAIL: XML master agent initialization fails: [chars] 

Explanation    XML master agent has failed initialization.

Recommended Action    No action is required.

Error Message     XMLMA-2-MTSERROR: XML master agent mts operation failed: [chars] 

Explanation    XML master agent mts operation failed.

Recommended Action    No action is required.

Error Message     XMLMA-2-PSSFAILURE: XML master agent pss operation failed: [chars] 

Explanation    XML master agent pss operation failed.

Recommended Action    No action is required.

XMLMA-3

Error Message     XMLMA-3-XMLMAERR: XML master agent: [chars] 

Explanation    XML master agent error log.

Recommended Action    No action is required.

XMLMA-5

Error Message     XMLMA-5-STARTING: XML master agent started [chars] 

Explanation    XML master agent has been started.

Recommended Action    No action is required.

XMLMA-6

Error Message     XMLMA-6-XMLMAEXIT: XML master agent exiting...: [chars] 

Explanation    XML master agent is exiting.

Recommended Action    No action is required.

Error Message     XMLMA-6-XMLMALOG: XML master agent operation log: [chars] 

Explanation    XML master agent operation log.

Recommended Action    No action is required.

XMLSA Messages

This section contains the XMLSA messages.

XMLSA-2

Error Message    XMLSA-2-HEARTBEAT_FAIL: XML sub agent failed sending heart beat: 
[chars] 

Explanation    XML sub agent failed sending heartbeat.

Recommended Action    No action is required.

Error Message     XMLSA-2-INITFAIL: XML sub agent initialization fails: [chars] 

Explanation    XML agent has failed initialization.

Recommended Action    No action is required.

Error Message     XMLSA-2-USER_INACTIVE: XML sub agent timeed out: [chars] 

Explanation    XML sub agent timedout due to inactivity.

Recommended Action    No action is required.

Error Message     XMLSA-2-VSH_ERR: XML sub agent vsh cmd error...: [chars] 

Explanation    XML sub agent vsh cmd error.

Recommended Action    No action is required.

XMLSA-5

Error Message     XMLSA-5-STARTING: XML sub agent started: [chars] 

Explanation    XML sub agent has been started.

Recommended Action    No action is required.

XMLSA-6

Error Message     XMLSA-6-XMLSAEXIT: XML sub agent exiting...: [chars] 

Explanation    XML sub agent is exiting.

Recommended Action    No action is required.

Error Message     XMLSA-6-XMLSALOG: XML sub agent log: [chars] 

Explanation    XML sub agent log.

Recommended Action    No action is required.

ZONE Messages

This section contains the ZONE messages.

ZONE-2

Error Message    ZONE-2-LZ_EXITING: LUN/Read-only zoning process exited. Reason: 
[chars] 

Explanation    The LUN/Read-only zoning process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     ZONE-2-LZ_GENERAL_ERROR: [chars] 

Explanation    The LUN/Read-only zoning process has encountered a critical error. The description of error is [str].

Recommended Action    No action is required.

Error Message     ZONE-2-LZ_INIT_FAILED: Initialization of LUN/Read-only zoning Process 
failed at [chars] 

Explanation    Initialization of LUN/Read-only zoning process failed at [char].

Recommended Action    No action is required.

Error Message     ZONE-2-LZ_MALLOC_ERROR: Size [dec] bytes 

Explanation    The LUN/Read-only zoning process could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     ZONE-2-ZS_ALIAS_LIMIT_EXCEEDED: The limit for maximum number of 
aliases exceeded 

Explanation    The number of aliases configured has exceeded the maximum number of aliases allowed per vsan Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of aliases is less than the maximum allowed in a vsan.

Error Message     ZONE-2-ZS_ATTR_GROUP_LIMIT_EXCEEDED: The limit for maximum number of 
attribute groups exceeded 

Explanation    The number of attribute groups configured has exceeded the maximum number of attribute groups allowed in a vsan Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of attribute groups is less than the maximum allowed in a vsan.

Error Message     ZONE-2-ZS_CHANGE_ACA_FAILED: ACA failed : [chars] 

Explanation    Zone Server cannot acquire change authorization : [chars].

Recommended Action    Verify the interoperability mode on all the switches OR retry later.

Error Message     ZONE-2-ZS_CHANGE_ACQUIRE_AUTH_FAILED: Acquire authorization failed on 
VSAN [dec] 

Explanation    Zone Server cannot acquire authorization on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_ACTIVATION_FAILED_RESN_DOM: Activation failed : 
reason [chars] domain [dec] 

Explanation    Zone Server cannot activate due to reason [chars] on domain [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_ACTIVATION_FAILED_RESN: Activation failed : reason 
[chars] 

Explanation    Zone Server cannot activate due to reason [chars].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_ACTIVATION_FAILED: Activation failed 

Explanation    Zone Server cannot activate the zoneset.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_APPLY_FAILED: Apply changed failed on VSAN [dec] 

Explanation    Zone Server cannot apply changes on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_DEACTIVATION_FAILED_RESN_DOM: Deactivation failed : 
reason [chars] domain [dec] 

Explanation    Zone Server cannot deactivate due to reason [chars] on domain [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_DEACTIVATION_FAILED_RESN: Deactivation failed : 
reason [chars] 

Explanation    Zone Server cannot deactivate due to reason [chars].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_DEACTIVATION_FAILED: Deactivation failed 

Explanation    Zone Server cannot deactivate the zoneset.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_RELEASE_AUTH_FAILED: Release authorization failed on 
VSAN [dec] 

Explanation    Zone Server cannot release authorization on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_SFC_FAILED: SFC failed : [chars] 

Explanation    Zone Server cannot stage zone configuration : [chars].

Recommended Action    Verify the interoperability mode on all the switches.

Error Message     ZONE-2-ZS_CHANGE_SFC_REJECTED: SFC received from remote domain [dec] 
is rejected: [chars] 

Explanation    Received invalid SFC from domain [dec]. : [chars]

Recommended Action    Verify the interoperability mode on the switch.

Error Message     ZONE-2-ZS_CHANGE_STAGE_ACTIVATE_ZSSET_BY_NAME_FAILED: Stage activate 
zoneset by name failed on VSAN [dec] 

Explanation    Zone Server cannot stage activate zoneset by name on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_ACTIVATE_ZSSET_ENH_FAILED: Stage activate 
zone set enhanced failed on VSAN [dec] 

Explanation    Zone Server cannot stage activate zone set enhanced on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_DEACTIVATE_ZSSET_ENH_FAILED: Stage deactivate 
zoneset enhanced failed on VSAN [dec] 

Explanation    Zone Server cannot stage deactivate zoneset enhanced on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_DISTRIBUTE_DFLT_ZONE_FAILED: Stage distribute 
default zone failed on VSAN [dec] 

Explanation    Zone Server cannot stage distribute default zone on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_DISTRIBUTE_ZS_DB_FAILED: Stage distribute 
zoneset database failed on VSAN [dec] 

Explanation    Zone Server cannot stage distribute zoneset database on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_SET_ZONING_MODE_FAILED: Stage set zoning mode 
failed on VSAN [dec] 

Explanation    Zone Server cannot stage set zoning mode on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_CHANGE_STAGE_SET_ZONING_POLICIES_FAILED: Stage set zoning 
policies failed on VSAN [dec] 

Explanation    Zone Server cannot stage set zoning policies on VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_DB_OPERATION_FAILED: Database operation error: [chars] 

Explanation    Database operation is failed : [chars].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_EXPORT_IMPORT_FAILED: [chars] operation failed 

Explanation    [chars] (Export/Import) operation failed.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_FIPS_COMPLIANCE_FAILURE: FIPS compliance error: 
consecutively same random numbers 

Explanation    FIPS compliance error: consecutively same random numbers

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_INIT_FAILED: [chars] 

Explanation    Zone Server initialization failed : [chars].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_LICENSE_UNAVAIL: License:[chars] unavailable, removing LUN 
members, read-only attribute and re-activating active zonesets on all affected 
VSANs

Explanation    License:[char] unavailable, removing LUN members, read-only attribute and re-activating active zonesets on all affected VSANs.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_LIC_FAILURE: License [chars] operation failed for license 
[chars] 

Explanation    License [char] operation failed for license [char].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_LUN_DISABLING_FAILED: license expiry handling failed for 
VSAN [dec] 

Explanation    License expiry handling failed for VSAN [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_LUN_MEMBER_LIMIT_EXCEEDED: The limit for maximum number of 
lun members exceeded 

Explanation    The number of lun members configured has exceeded the maximum number of lun members allowed across all vsans Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of lun members is less than the maximum allowed across all vsans.

Error Message     ZONE-2-ZS_MALLOC_FAILURE: Memory allocation failed for size [dec] 

Explanation    Memory allocation is failed for size [dec] bytes.

Recommended Action    Restart the process.

Error Message     ZONE-2-ZS_MEMBER_LIMIT_EXCEEDED: The limit for maximum number of 
members exceeded 

Explanation    The number of members configured has exceeded the maximum number of members allowed across all vsans Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of members is less than the maximum allowed across all vsans.

Error Message     ZONE-2-ZS_MERGE_ADJ_NO_RESPONSE: Adjacent switch not responding, 
isolating interface [chars] 

Explanation    Interface [chars] isolated due to adjacent switch not responding to Zone Server requests.

Recommended Action    Flap the interface.

Error Message     ZONE-2-ZS_MERGE_FAILED: Zone merge failure, isolating interface 
[chars] [chars] 

Explanation    Interface [chars] isolated due to zone merge failure. error [chars]

Recommended Action    Compare active zoneset with the adjacent switch OR use zone merge interface [interface] {import/export} VSAN [VSAN-num] command.

Error Message     ZONE-2-ZS_MERGE_FULL_DATABASE_MISMATCH: Zone merge full database 
mismatch on interface [chars] 

Explanation    Full zoning databases are inconsistent between two switches connected by interface [chars]. Databases are not merged.

Recommended Action    Compare full zoning database with the adjacent switch, correct the difference and flap the link.

Error Message     ZONE-2-ZS_MERGE_UNKNOWN_FORMAT: Unknown format, isolating interface 
[chars] 

Explanation    Interface [chars] isolated due to unknown format in merge request.

Recommended Action    Set the interoperability mode to same value on both switches.

Error Message     ZONE-2-ZS_MTS_OPER_FAILED: MTS [chars] operation failed : [chars] 

Explanation    Zone Server MTS [chars] operation failed : [chars].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_PORT_SWAP_FAILURE: Port swap operation failed 

Explanation    Port swap operation failed.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_PSS_VER_MISMATCH: PSS version mismatch URL: [chars] 
(expected [chars], got [chars]) 

Explanation    Configuration version mismatch. PSS URL [chars]. Expected version [chars], stored version [chars].

Recommended Action    Upgrade/Downgrade to expected version.

Error Message     ZONE-2-ZS_TCAM_BROADCAST_ZONE_DISABLED: Broadcast zoning disabled : 
Reason: Hard zoning disabled

Explanation    Broadcast zoning disabled : Reason: Hard zoning disabled due to TCAM programming failure.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_TCAM_LUN_ZONING_DISABLED: LUN zoning disabled : Reason: 
Hard zoning disabled

Explanation    LUN zoning disabled : Reason: Hard zoning disabled due to TCAM programming failure.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_TCAM_PROGRAMMING_FAILED: TCAM operation failed : [chars], 
Reason: [chars] 

Explanation    TCAM Programming failure has occurred : [chars]. [chars] is the reason for failure.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_TCAM_READ_ONLY_ZONE_DISABLED: Read-only zoning disabled : 
Reason: Hard zoning disabled

Explanation    Read-only zoning disabled : Reason: Hard zoning disabled due to TCAM programming failure.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_TCAM_SWITCHED_TO_SOFT_ZONING_MODE: Switched to soft zoning 
: Reason: Hard zoning disabled

Explanation    Switched to soft zoning : Reason: Hard zoning disabled due to TCAM programming failure.

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_VIRTUAL_DOMAIN_INCONSISTENT: IVR reporting virtual domain 
different from rib and domain manager in vsan [dec]

Explanation    IVR reporting virtual domain different from rib and domain manager in vsan [dec].

Recommended Action    No action is required.

Error Message     ZONE-2-ZS_ZONE_LIMIT_EXCEEDED: The limit for maximum number of zones 
exceeded 

Explanation    The number of zones configured has exceeded the maximum number of zones allowed across all vsans Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of zones is less than the maximum allowed across all vsans.

Error Message     ZONE-2-ZS_ZONE_SET_LIMIT_EXCEEDED: The limit for maximum number of 
zonesets exceeded 

Explanation    The number of zonesets configured has exceeded the maximum number of zonesets allowed across all vsans Due to this, distribution or merge operation may fail.

Recommended Action    Make sure the number of zonesets is less than the maximum allowed across all vsans.

ZONE-3

Error Message     ZONE-3-LZ_UNKNOWN_MSG: Recvd. from Node=[dec] SAP=[dec] 

Explanation    The LUN/Read-only zoning process has received an unknown message from [dec]].[dec]. This information is for debugging only.

Recommended Action    No action is required.

Error Message     ZONE-3-ZS_ACTIVATION_FAILED_DUE_TO_QOS_DISABLED: Activation failed 
due to qos not enabled 

Explanation    Activation of zoneset failed due to qos not enabled

Recommended Action    Make sure qos is enabled and reactivate the zoneset in vsan.

ZONE-4

Error Message     ZONE-4-LZ_OTHER_CMD_TO_ZONED_OUT_LUN: FCP command [hex] received from 
SID=[chars] to DID=[chars] for LUN=[chars] 

Explanation    The LUN/Read-only zoning process has received. FCP command [int] from SID [char] to DID [char] for a zoned out LUN [char].

Recommended Action    No action is required.

Error Message     ZONE-4-ROZ_WRITE_ACCESS_TO_READ_ONLY_LUN: FCP command [hex] received 
from SID=[chars] to DID=[chars] for LUN=[chars] 

Explanation    The LUN/Read-only zoning process has received FCP command [int] from SID [char] to DID [char] for a read-only LUN [char].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_BROADCAST_LUN_WARNING: LUN member(s) and Broadcast 
attribute are present in zone [chars] in vsan [dec]. Broadcast violations can occur 
for LUN members.

Explanation    Broadcast violations can happen in zone [chars] in vsan [dec] since it has LUN zone members.

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_CHANGE_LC_UPGRADE_IN_PROGRESS: Change protocol request is 
received from domain [dec] when linecard upgrade is in progress

Explanation    A change request has been received from domain [dec] when a linecard upgrade is in progress. The change request is rejected.

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_DB_WARNING: [chars] 

Explanation    Database operation warning: [chars].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_DOMAIN_MGR_WARNING: Unable to retrieve domain info from 
domain mgr error: [chars] in vsan [dec]

Explanation    Unable to retrieve info of domain from domain manager, error: [chars] in vsan [dec].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_FC2_OPER_FAILED: FC2 [chars] operation failed : [chars] 

Explanation    Zone Server FC2 [chars] operation failed : [chars].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_IF_PORT_MODE_CONFLICT: Port mode conflict for if [chars] 

Explanation    Port mode conflict for if [chars]

Recommended Action    Shutdown/no shutdown the interface

Error Message     ZONE-4-ZS_INVALID_FPORT_WWN_MEMBER: Virtual device fwwn: [chars] is 
not a valid zone/alias member virtual name: [chars] pwwn: [chars]

Explanation    Virtual device fwwn: [chars] is not a valid zone/alias member, virtual name: [chars] pwwn: [chars].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_LC_UPGRADE_CHANGE_IN_PROGRESS: Linecard upgrade request is 
received when change protocol is in progress

Explanation    A request for linecard upgrade has been received when change protocol is in progress. The linecard upgrade will occur after the completion of the change protocol.

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_LICENSE_EXPIRY_WARNING: Feature [chars] evaluation license 
[chars] expiry in [dec] days 

Explanation    Feature [chars1] will exceed it's evaluation time period in [dec] days and will be shut down unless a permanent license [chars2] is installed.

Recommended Action    Please install the license file to continue using the feature.

Error Message     ZONE-4-ZS_MEMBER_CONVERSION_FAILED: Zone Member conversion failed for 
[chars]. Error: [chars]

Explanation    Zone Member conversion has failed in : [chars] due to error: [chars]

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_NON_INTEROPERABLE_ZONE_SET: Non interoperable active 
zoneset present on VSAN [dec] in interoperability mode

Explanation    Active zoneset has non interoperable members (FCID, FWWN, ..) when interoperability mode is turned on the VSAN [dec].

Recommended Action    Turn off interoperability mode OR make sure that active zoneset has only interoperable members (PWWN).

Error Message     ZONE-4-ZS_QOS_LUN_WARNING: LUN member(s) and QoS attribute are 
present in zone [chars] in vsan [dec]. QoS will not be applicable for LUN members.

Explanation    QoS will not be applicable to LUN zone members in zone [chars] in vsan [dec].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_SDV_VIRT_REAL_CONFLICT_WARNING: Virtual and Real devices 
are zoned together or zoned with same device. virtual name: [chars] pwwn: [chars]

Explanation    Virtual and Real devices are zoned together or zoned with same device, virtual name: [chars] pwwn: [chars].

Recommended Action    No action is required.

Error Message     ZONE-4-ZS_TOO_MANY_ALIAS_IN_CURRENT_INTEROP_MODE: Too many aliases in 
current interoperability mode 

Explanation    Too many aliases configured in current interoperability mode on the VSAN. Due to this, the next zoneset activation, distribution or merge operation may fail.

Recommended Action    Set the interoperability mode to appropriate value OR make sure the number of aliases is less than the maximum allowed in the current interoperability mode.

Error Message     ZONE-4-ZS_UNSUPPORTED_MEMBER_IN_CURRENT_INTEROP_MODE: Unsupported 
member present in active or full zoneset in current interoperability mode

Explanation    Active or full zoneset has members that are not supported in the current interoperability mode set on the VSAN.

Recommended Action    Set the interoperability mode to appropriate value OR make sure that active or full zoneset has only supported members in the current interoperability mode.

ZONE-5

Error Message     ZONE-5-ZS_EXPORT_IMPORT_COMPLETE: [chars] operation completed 

Explanation    [chars] (Export/Import) operation completed.

Recommended Action    No action is required.

Error Message     ZONE-5-ZS_POLICY_CHANGE: Default zoning policy changed to [chars] 

Explanation    Default zoning policy changed to (permit/deny).

Recommended Action    No action is required.

Error Message     ZONE-5-ZS_ZONE_SET_ACTIVATED: Zoneset [chars] activated 

Explanation    Zoneset [chars] activated.

Recommended Action    No action is required.

Error Message     ZONE-5-ZS_ZONE_SET_DEACTIVATED: Zoneset deactivated 

Explanation    Zoneset deactivated.

Recommended Action    No action is required.

ZONE-6

Error Message     ZONE-6-LZ_BECAME_ACTIVE: LUN/Read-only zoning process became ACTIVE 
from standby mode 

Explanation    The LUN/Read-only zoning process on the standby supervisor became active.

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_BECAME_STDBY: LUN/Read-only zoning process became STANDBY 
from active mode 

Explanation    The LUN/Read-only zoning process became standby from active mode.

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_FAILED_TO_SEND_HEARTBEAT: LUN/Read-only zoning process 
failed to send heartbeat to system manager: Reason=[chars]

Explanation    The LUN/Read-only zoning process was unable to send heartbeat to the system manager.

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_GENERAL_EVENT: [chars] 

Explanation    The LUN/Read-only zoning process has generated an important event. The description of the event is [str].

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_INQUIRY_TO_ZONED_OUT_LUN: INQUIRY command received from 
SID=[chars] to DID=[chars] for LUN=[chars] 

Explanation    The LUN/Read-only zoning process has received INQUIRY FCP command from SID [char] to DID [char] for a zoned out LUN [char].

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_REPORT_LUNS_CMD_RCVD: REPORT LUNS command received from 
SID=[chars] to DID=[chars] for LUN=[chars] 

Explanation    The LUN/Read-only zoning process has received REPORT LUNS FCP command from SID [char] to DID [char] for LUN [char].

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_REQUEST_SENSE_TO_ZONED_OUT_LUN: REQUEST SENSE command 
received from SID=[chars] to DID=[chars] for LUN=[chars] 

Explanation    The LUN/Read-only zoning process has received. REQUEST SENSE FCP command from SID [char] to DID [char] for a zoned out LUN [char].

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_SERVICE_UP: LUN/Read-only zoning Process initialized 
[chars] 

Explanation    The LUN/Read-only zoning process is up. The process was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     ZONE-6-LZ_SWITCHOVER: LUN/Read-only zoning process switching over to 
other supervisor.

Explanation    The LUN/Read-only zoning process has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

Error Message     ZONE-6-ZS_CHANGE_ACA_REJECTED: ACA received from remote domain [dec] 
is rejected 

Explanation    Received invalid ACA from domain [dec]. Either the domain list do not match OR authorization has already been acquired by another switch.

Recommended Action    Verify the interoperability mode on the switch.

Error Message     ZONE-6-ZS_FC2_OPER_INFO: FC2 [chars] operation failed : [chars] 

Explanation    Zone Server FC2 [chars] operation failed : [chars].

Recommended Action    No action is required.

Error Message     ZONE-6-ZS_INIT_PROCESS: Zone Server process started [chars] at 
[chars] 

Explanation    Zone Server process started in [chars] (stateless/stateful) mode at time [chars].

Recommended Action    No action is required.

Error Message     ZONE-6-ZS_INIT_WARNING: [chars] 

Explanation    Warning during Zone Server Initialization: [chars].

Recommended Action    No action is required.

Error Message     ZONE-6-ZS_INVALID_MEMBER: Invalid member [dec] [chars] 

Explanation    Invalid member type [dec] [chars] recieved from the API call.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ZONE-6-ZS_UNKNOWN_LIC_FEATURE: [chars] 

Explanation    Zone Server received an event for an known licensing feature: [chars].

Recommended Action    No action is required.