System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family

Table Of Contents

System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family

AAA Messages

AAA-1

AAA-2

AAA-3

AAA-6

AAM Messages

AAM-2

AAM-3

ACLLOG Messages

ACLLOG-4

ACLLOG-6

ACLMGR Messages

ACLMGR-2

ACLMGR-3

ACLMGR-4

ACLMGR-6

ACLQOS Messages

ACLQOS-SLOT#-2

ACLQOS-SLOT#-3

ACLQOS-SLOT#-4

ACLQOS-SLOT#-5

ACLTCAM Messages

ACLTCAM-2

ACLTCAM-3

ACLTCAM-4

ACLTCAM-6

ACL Messages

ACL-2

ACL-4

ACL-5

ACL-6

ASCII-CFG Messages

ASCII-CFG-2

ASCII-CFG-3

ASCII-CFG-6

BIOS DAEMON Messages

BIOS DAEMON-2

BIOS_DAEMON-SLOT#-2

BOOTUP TEST Messages

BOOTUP TEST-2

BOOTVAR Messages

BOOTVAR-2

BOOTVAR-3

BOOTVAR-5

BOOTVAR-6

CALLHOME Messages

CALLHOME-2

CALLHOME-3

CALLHOME-6

CDP Messages

CDP-2

CDP-3

CDP-4

CDP-5

CDP-6

CERT_ENROLL Messages

CERT_ENROLL-2

CERT_ENROLL-3

CERT_ENROLL-6

CFS Messages

CFS-2

CFS-3

CFS-4

CFS-6

CIMSRVPROV Messages

CIMSRVPROV-2

CIMSRVPROV-3

CIMSRVPROV-6

CLIS Messages

CLIS-5

CLOUD Messages

CLOUD-2

CLOUD-3

CLOUD-6

CLUSTER Messages

CLUSTER-2

CMPPROXY Messages

CMPPROXY-2

CMPPROXY-5

CMPPROXY-6

COPP Messages

COPP-2

COPP-3

COPP-5

COPP-6

CORE-DMON Messages

CORE-DMON-2

CORE-DMON-3

CPPA_MGR Messages

CPPA_MGR-3

CPPA_MGR-5

CREDITMON Messages

CREDITMON-SLOT#-2

CTS Messages

CTS-2

CTS-3

CTS-5

DEBUGPROXY Messages

DEBUGPROXY-6

DEVICE-ALIAS Messages

DEVICE-ALIAS-2

DEVICE-ALIAS-3

DEVICE-ALIAS-6

DEVICE_TEST Messages

DEVICE_TEST-2

DEVICE_TEST-3

DEVICE_TEST-4

DEVICE_TEST-5

DEVICE_TEST-6

DEV_LOG Messages

DEV_LOG-3

DEV_LOG-SLOT#-4

DFTM Messages

DFTM-3

DHCP_SNOOP Messages

DHCP_SNOOP-2

DHCP_SNOOP-3

DHCP_SNOOP-4

DHCP_SNOOP-6

DIAGCLIENT Messages

DIAGCLIENT-2

DIAGCLIENT-3

DIAGCLIENT-4

DIAGCLIENT-5

DIAGMGR Messages

DIAGMGR-2

DIAGMGR-3

DIAGMGR-4

DIAGMGR-5

DIAGMGR-6

DIAG_PORT_LB Messages

DIAG_PORT_LB-2

DIAG_PORT_LB-3

DIAG_PORT_LB-5

DMM Messages

DMM-SLOT#-5

DOT1X Messages

DOT1X-2

DOT1X-3

DOT1X-4

DOT1X-5

DPP_DEBUG Messages

DPP_DEBUG-2

DPVM Messages

DPVM-2

DPVM-3

DPVM-4

DPVM-6

DSTATS Messages

DSTATS-2

DSTATS-3

ELTMC Messages

ELTMC-SLOT#-2

ELTM Messages

ELTM-2

ELTM-6

EOU Messages

EOU-2

EOU-5

EOU-6

EOU-7

EPP Messages

EPP-5

ETH-PORT-SEC Messages

ETH-PORT-SEC-2

ETH-PORT-SEC-3

ETH-PORT-SEC-5

ETHPORT Messages

ETHPORT-2

ETHPORT-3

ETHPORT-4

ETHPORT-5

ETH_PORT_CHANNEL Messages

ETH_PORT_CHANNEL-1

ETH_PORT_CHANNEL-2

ETH_PORT_CHANNEL-3

ETH_PORT_CHANNEL-4

ETH_PORT_CHANNEL-5

ETH_PORT_CHANNEL-6

ETH_PORT_CHANNEL-7

EUREKA_USD Messages

EUREKA_USD-3

EVMC Messages

EVMC-5

EVMS Messages

EVMS-2

EVMS-4

EXCEPTIONLOG Messages

EXCEPTIONLOG-SLOT#-2

FC-TUNNEL Messages

FC-TUNNEL-3

FC-TUNNEL-5

FCC_LC Messages

FCC_LC-2

FCC_LC-5

FCC-5

FCC-6

FCDDH Messages

FCDDH-SLOT#-3

FCDDH-SLOT#-4

FCDDH-SLOT#-5

FCDD Messages

FCDD-SLOT#-3

FCDD-SLOT#-4

FCDD-SLOT#-5

FCDD-SLOT#-7

FCDOMAIN Messages

FCDOMAIN-2

FCDOMAIN-3

FCDOMAIN-4

FCDOMAIN-5

FCDOMAIN-6

FCDOMAIN-7

FCFWD Messages

FCFWD-3

FCFWD-4

No action is required.

FCNS Messages

FCNS-2

FCNS-3

FCNS-4

FCNS-6

FCSP-MGR Messages

FCSP-MGR-2

FCS Messages

FCS-2

FCS-3

FCS-4

FCS-5

FCS-6

FDMI Messages

FDMI-2

FDMI-3

FDMI-4

FDMI-6

FEATURE-MGR Messages

FEATURE-MGR-2

FICON Messages

FICON-2

FICON-3

FICON-5

FICON-6

FLOGI Messages

FLOGI-1

FLOGI-2

FLOGI-4

FLOGI-5

FS-DAEMON Messages

FS-DAEMON-2

FS-DAEMON-6

FSCM Messages

FSCM-2

FSPF Messages

FSPF-2

FSPF-3

FSPF-4

FSPF-5

FSPF-6

FSPF-7

FWM Messages

FWM-0

FWM-1

FWM-2

FWM-3

FWM-4

FWM-6

GLBP Messages

GLBP-2

GLBP-3

GLBP-4

GLBP-5

HSRP_ENGINE Messages

HSRP_ENGINE-3

HSRP_ENGINE-4

HSRP_ENGINE-6

IKE Messages

IKE-3

IKE-4

IKE-6

ILC-SPAN Messages

ILC-SPAN-3

ILC_HELPER Messages

ILC_HELPER-2

ILC_HELPER-3

ILC_HELPER-6

IMAGE_DNLD Messages

IMAGE_DNLD-SLOT#-2

IMAGE_DNLD-SLOT#-4

IMAGE_DNLD-SLOT#-5

IMAGE_UPGRADE Messages

IMAGE_UPGRADE-SLOT#-2

IMAGE_UPGRADE-SLOT#-4

IM Messages

IM-3

IM-5

INTERFACE_VLAN Messages

INTERFACE_VLAN-5

IOA_LC Messages

IOA_LC-5

IPACL Messages

IPACL-0

IPACL-1

IPACL-2

IPACL-4

IPACL-5

IPACL-6

IPFC Messages

IPFC-2

IPFC-3

IPFC-5

IPFC-6

IPPOOL Messages

IPPOOL-3

IPPOOL-5

IPQOSMGR Messages

IPQOSMGR-2

IPQOSMGR-3

IPQOSMGR-4

IPQOSMGR-6

IPQOSMGR-SLOT#-3

IPSEC Messages

IPSEC-2

IPSEC-3

IPSEC-5

IPS_SB_MGR Messages

IPS_SB_MGR-SLOT#-2

IPS_SB_MGR-SLOT#-3

IPS_SB_MGR-SLOT#-4

IPS_SB_MGR-SLOT#-6

IPS Messages

IPS-2

IPS-3

IPS-4

IPS-5

IPS-7

IPV6 Messages

IPV6-2

IPV6-3

IPV6-4

IPV6-6

IP Messages

IP-2

IP-3

IP-4

IP-6

ISAPI Messages

ISAPI-SLOT#-0

ISAPI-SLOT#-1

ISAPI-SLOT#-2

ISAPI-SLOT#-3

ISAPI-SLOT#-4

ISAPI-SLOT#-5

ISAPI-SLOT#-6

ISAPI-SLOT#-7

ISNS Messages

ISNS-2

IVR Messages

IVR-2

IVR-3

IVR-4

IVR-5

IVR-6

IVR-7

L2FMC Messages

L2FMC-SLOT#-0

L2FMC-SLOT#-2

L2FMC-SLOT#-5

L2FMC-SLOT#-6

L2FM Messages

L2FM-0

L2FM-1

L2FM-2

L2FM-6

L2MCAST Messages

L2MCAST-SLOT#-0

L2MCAST-SLOT#-2

L2MCAST-SLOT#-6

LACP Messages

LACP-3

LACP-5

LC-FCFWD Messages

LC-FCFWD-3

LC-SPAN Messages

LC-SPAN-3

LC_CFG Messages

LC_CFG-SLOT#-2

LC_PORT_CHANNEL Messages

LC_PORT_CHANNEL-SLOT#-0

LC_PORT_CHANNEL-SLOT#-3

LC_PORT_MGR Messages

LC_PORT_MGR-SLOT#-2

LC_RDL Messages

LC_RDL-3

LC_RDL-6

LIBBASE_SVC Messages

LIBBASE_SVC-2

LIBBASE_SVC-5

LIBGD Messages

LIBGD-2

LIBGD-3

LIBGD-5

LIBGD-6

LICMGR Messages

LICMGR-2

LICMGR-3

LICMGR-4

LICMGR-6

LLDP Messages

LLDP-3

LLDP-5

LLDP-6

MAC Messages

MAC-SLOT#-2

MCAST Messages

MCAST-2

MCAST-4

MCAST-5

MCECTEST Messages

MCECTEST-3

MCECTEST-5

MCECTEST-6

MCM Messages

MCM-5

MFDM Messages

MFDM-2

MODULE Messages

MODULE-2

MODULE-3

MODULE-4

MODULE-5

MODULE-6

MONITOR Messages

MONITOR-3

MONITOR-5

MONITOR-6

NFM Messages

NFM-2

NFM-3

NFM-4

NFM-5

NFM-6

NFM-7

NFP Messages

NFP-SLOT#-2

NPC Messages

NPC-SLOT#-3

NPC-SLOT#-4

NPC-SLOT#-5

NPV Messages

NPV-2

NPV-3

NPV-4

NPV-5

NPV-6

NPV-7

NTP Messages

NTP-2

NTP-3

NTP-6

NVP Messages

NVP-6

NVP-SLOT#-2

OC_USD Messages

OC_USD-2

ORI_MAC Messages

ORI_MAC-6

OTM Messages

OTM-2

OTM-3

OTM-5

OTM-6

PHY_USD Messages

PHY_USD-SLOT#-4

PIXM Messages

PIXM-2

PIXM-3

PIXM-4

PLATFORM Messages

PLATFORM-0

PLATFORM-1

PLATFORM-2

PLATFORM-3

PLATFORM-4

PLATFORM-5

PLATFORM-6

PLATFORM-7

PLOG_SUP Messages

PLOG_SUP-4

PLOG Messages

PLOG-4

POLICY_ENGINE Messages

POLICY_ENGINE-5

POLICY_ENGINE-6

PORT-CHANNEL Messages

PORT-CHANNEL-1

PORT-CHANNEL-2

PORT-CHANNEL-3

PORT-CHANNEL-4

PORT-CHANNEL-5

PORT-CHANNEL-6

PORT-CHANNEL-7

PORT-PROFILE Messages

PORT-PROFILE-2

PORT-PROFILE-3

PORT-PROFILE-6

PORT-RESOURCES Messages

PORT-RESOURCES-3

PORT-RESOURCES-5

PORT-SECURITY Messages

PORT-SECURITY-2

PORT-SECURITY-3

PORT-SECURITY-4

PORT-SECURITY-6

PORT Messages

PORT-2

PORT-3

PORT-4

PORT-5

PRIVATE_VLAN Messages

PRIVATE_VLAN-3

PRIVATE_VLAN-5

PROC_MGR Messages

PROC_MGR-SLOT#-2

PROC_MGR-SLOT#-3

PROC_MGR-SLOT#-4

PROC_MGR-SLOT#-6

PSS Messages

PSS-0

PSS-1

PSS-2

PSS-4

PSS-5

QOS Messages

QOS-2

QOS-3

QOS-4

QOS-6

RADIUS Messages

RADIUS-2

RADIUS-3

RADIUS-5

RADIUS-6

RDL Messages

RDL-2

RDL-3

RDL-6

RES_MGR Messages

RES_MGR-1

RES_MGR-2

RES_MGR-3

RES_MGR-4

RES_MGR-5

RES_MGR-6

RIB Messages

RIB-0

RIB-1

RIB-2

RIB-3

RIB-4

RIB-5

RIB-6

RLIR Messages

RLIR-2

RLIR-6

RM Messages

RM-6

RM-SLOT#-2

RM-SLOT#-4

RSCN Messages

RSCN-2

RSCN-4

RSCN-6

SAL Messages

SAL-5

SAN_EXT_TUNER Messages

SAN_EXT_TUNER-3

SCHEDULER Messages

SCHEDULER-2

SCHEDULER-3

SCHEDULER-4

SCHEDULER-6

SCSI-TARGET Messages

SCSI-TARGET-2

SCSI-TARGET-3

SCSI-TARGET-7

SDV Messages

SDV-2

SDV-3

SDV-4

SDV-6

SDV-7

SECURITYD Messages

SECURITYD-2

SECURITYD-3

SECURITYD-5

SECURITYD-6

SENSOR_USD Messages

SENSOR_USD-2

SENSOR_USD-3

SENSOR_USD-5

SENSOR_MGR Messages

SENSOR_MGR-2

SENSOR_MGR-3

SENSOR_MGR-4

SFC Messages

SFC-3

SFM Messages

SFM-2

SFM-6

SKSD Messages

SKSD-5

SKT_USD Messages

SKT_USD-3

SME_CPP Messages

SME_CPP-2

SME_CPP-3

SME_CPP-5

SME_CPP-SLOT#-2

SME_CPP-SLOT#-3

SME_CPP-SLOT#-4

SNMPD Messages

SNMPD-1

SNMPD-2

SNMPD-3

SNMPD-4

SNMPD-5

SNMPD-6

SNMPD-7

SPAN Messages

SPAN-2

SPAN-3

SPAN-5

SPAN-6

SPI Messages

SPI-SLOT#-2

STP Messages

STP-2

STP-3

STP-4

STP-6

SVC_BATTERY Messages

SVC_BATTERY-SLOT#-2

SVC_BATTERY-SLOT#-4

SVC_BATTERY-SLOT#-6

SVC Messages

SVC-0

SVC-1

SVC-2

SVC-3

SVC-4

SVC-5

SVC-6

SVC-7

SYSMGR Messages

SYSMGR-2

SYSMGR-3

SYSMGR-4

SYSMGR-5

SYSMGR-6

SYSMGR-7

SYSTEMHEALTH Messages

SYSTEMHEALTH-2

SYSTEMHEALTH-4

SYSTEMHEALTH-5

SYSTEMHEALTH-6

TACACS Messages

TACACS-2

TACACS-3

TACACS-5

TACACS-6

TCAP Messages

TCAP-2

TLPORT Messages

TLPORT-2

TLPORT-3

TLPORT-4

TLPORT-6

TPC Messages

TPC-SLOT#-5

TTYD Messages

TTYD-2

TTYD-3

TTYD-6

TUNNEL Messages

TUNNEL-3

TUNNEL-4

TUNNEL-5

TUNNEL-7

UDLD Messages

UDLD-3

UDLD-4

UDLD-5

UFDM Messages

UFDM-2

VDC_MGR Messages

VDC_MGR-2

VDC_MGR-3

VDC_MGR-6

VEC Messages

VEC-SLOT#-3

VEC-SLOT#-4

VEC-SLOT#-5

VEDB_MGR Messages

VEDB_MGR-2

VEDB_MGR-6

VEM_MGR Messages

VEM_MGR-2

VEM_MGR-3

VEM_MGR-5

VEM_MGR-6

VES Messages

VES-SLOT#-4

VES-SLOT#-5

VFC Messages

VFC-3

VFC-6

VIM Messages

VIM-5

VLAN_MGR Messages

VLAN_MGR-2

VLAN_MGR-6

VMM Messages

VMM-2

VMS Messages

VMS-2

VMS-3

VMS-5

VNI Messages

VNI-2

VNI-3

VNI-6

VNS_AGENT Messages

VNS_AGENT-2

VNS_AGENT-3

VNS_AGENT-5

VNS_AGENT-6

VNS_AGENT-7

VPC Messages

VPC-2

VPC-3

VPC-4

VPC-5

VPC-6

VPM Messages

VPM-2

VPM-3

VPM-4

VPM-6

VPM-SLOT#-2

VRRP-CFG Messages

VRRP-CFG-2

VRRP-CFG-3

VRRP-CFG-5

VRRP-ENG Messages

VRRP-ENG-2

VRRP-ENG-3

VRRP-ENG-4

VRRP-ENG-5

VRRP-ENG-6

VSAN Messages

VSAN-2

VSAN-3

VSAN-6

VSD Messages

VSD-SLOT#-2

VSHD Messages

VSHD-2

VSHD-3

VSHD-4

VSHD-5

VSHD-7

WWN Messages

WWN-1

WWN-2

WWN-3

WWN-4

WWN-5

WWN-6

WWN-7

XBAR_CLIENT Messages

XBAR_CLIENT-2

XBAR_CLIENT-3

XBAR_CLIENT-SLOT#-2

XBAR_CLIENT-SLOT#-3

XBAR Messages

XBAR-2

XBAR-3

XBAR-5

XMLMA Messages

XMLMA-2

XMLMA-3

XMLMA-5

XMLMA-6

XMLSA Messages

XMLSA-2

XMLSA-5

XMLSA-6

ZONE Messages

ZONE-2

ZONE-3

ZONE-4

ZONE-5

ZONE-6


System Messages and Recovery Procedures for the Cisco Nexus 1000 and Nexus 1010 Family


This chapter includes system messages for the Cisco NX-OS Nexus1000 and Nexus 1010 families of switches. The messages are listed in alphabetical order by the system facility that produces them. Within each system facility section, messages are listed alphabetically by severity and mnemonics. Each error message is followed by an explanation and a recommended action.

AAA Messages

This section contains the AAA messages.

AAA-1

Error Message    AAA-1-AAA_SESSION_LIMIT_REJECT: aaa request rejected as maximum aaa 
sessions are in progress 

Explanation    Aaa request rejected as the limit for maximum concurrent aaa sessions is reached

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-2

Error Message     AAA-2-AAA_NVRAM_UPGRADE_FAILURE: upgrading of accounting log failed. 
[chars] 

Explanation    Upgrading of accounting log failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     AAA-2-AAA_PROGRAM_EXIT: aaa daemon exiting: [chars] 

Explanation    Aaa daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-3

Error Message     AAA-3-AAA_NVRAMFAILURE: nvram failure 

Explanation    Nvram can not be read/written to. Hence accounting log can not be stored there

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

AAA-6

Error Message     AAA-6-AAA_ACCOUNTING_MESSAGE: [chars] 

Explanation    Accounting Message

Recommended Action    No action is required.

AAM Messages

This section contains the AAM messages.

AAM-2

Error Message    AAM-2-ELS_FC2_GL_SINDEX_LOOKUP_FAILED: Failed to lookup global port 
index for interface [[chars]] 

Explanation    Failed to lookup global port index for interface [chars]

Recommended Action    No action is required.

AAM-3

Error Message     AAM-3-ALLOC_FAILED: Failed in File:[chars] Line:[dec] for type [dec] 
size [dec] 

Explanation    AAM process could not allocate heap memory in File:[chars], at line:[dec], for memory-type:[dec] of Size:[dec]

Recommended Action    No action is required.

Error Message     AAM-3-ASSERTION_FAILED: Failed in File:[chars] Line:[dec] 

Explanation    AAM Process assertion failed in File:[chars], at line:[dec]

Recommended Action    No action is required.

ACLLOG Messages

This section contains the ACLLOG messages.

ACLLOG-4

Error Message    ACLLOG-4-ACLLOG_MAXFLOW_REACHED: [chars] 

Explanation    Max flow reached in current interval: [chars]

Recommended Action    No action is required.

Error Message     ACLLOG-4-ACLLOG_THRESHOLD: [chars] 

Explanation    Threshold Reached for Flow: [chars]

Recommended Action    No action is required.

ACLLOG-6

Error Message     ACLLOG-6-ACLLOG_FLOW_INTERVAL: [chars] 

Explanation    Flow info in current alert interval: [chars]

Recommended Action    No action is required.

Error Message     ACLLOG-6-ACLLOG_NEW_FLOW: [chars] 

Explanation    New Acllog Flow: [chars]

Recommended Action    No action is required.

ACLMGR Messages

This section contains the ACLMGR messages.

ACLMGR-2

Error Message     ACLMGR-2-ACLMGR_COMMIT_FAIL: Commit failed: client %llX, [chars] 

Explanation    The PPF commit failed

Recommended Action    No action is required.

Error Message     ACLMGR-2-ACLMGR_NO_ERRDISABLED: [chars] event on interface [chars] 
([hex]) allowed to succeed in spite of access-list failure 

Explanation    Although an access-list operation failed during a port event, the port event still finished successfully because errdisable is disallowed

Recommended Action    No action is required.

Error Message     ACLMGR-2-EXITING: Exit reason: [chars] 

Explanation    The ACLMGR service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     ACLMGR-2-INITFAIL: ACLMGR Service Init failed: [chars] 

Explanation    ACLMGR Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     ACLMGR-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The ACLMGR service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     ACLMGR-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The ACLMGR service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

ACLMGR-3

Error Message    ACLMGR-3-ACLMGR_ACL_ON_FAB_INACTIVE: ACL on FEX fabric interface not 
activated 

Explanation    ACL applied to a FEX fabric port or port-channel is not activated

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_ACL_OVER_FAB_CHANNEL: ACL on FEX fabric port-channel 
bound interface not activated 

Explanation    ACL applied to a FEX interface is not activated if the interface is bound to a FEX-fabric portchannel

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_PPF_ERROR: PPF error: [chars] 

Explanation    The PPF generated error

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The ACLMGR service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_STAT_CONSOLIDATION_FAILURE: ACL statistic parsing or 
consolidation failed 

Explanation    A statistic update failed during the parsing or consolidation step; statistics may have been lost

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_VACL_REDIRECTION_DISABLED_REMOVAL: VACL redirection 
to interface [chars] ([hex]) disabled: the port has been removed 

Explanation    A VACL redirection to the port has been deactivated because the port has been removed

Recommended Action    No action is required.

Error Message     ACLMGR-3-ACLMGR_VERIFY_FAIL: Verify failed: client %llX, [chars] 

Explanation    The PPF Verify failed

Recommended Action    No action is required.

Error Message     ACLMGR-3-MTSERROR: [chars] 

Explanation    ACLMGR Service encountered an MTS error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

ACLMGR-4

Error Message     ACLMGR-4-ACLMGR_PPF_WARNING: PPF warning: [chars] 

Explanation    The PPF generated warning

Recommended Action    No action is required.

Error Message     ACLMGR-4-ACLMGR_VACL_REDIRECTION_DISABLED_PCM: VACL redirection to 
interface [chars] ([hex]) disabled: the port became a portchannel member 

Explanation    A VACL redirection to the port has been temporarily deactivated because it is now a member in a port channel

Recommended Action    No action is required.

Error Message     ACLMGR-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the ACLMGR service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

ACLMGR-6

Error Message     ACLMGR-6-ACLMGR_PPF_NOTIF: PPF notification: [chars] 

Explanation    The PPF generated notification

Recommended Action    No action is required.

Error Message     ACLMGR-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The ACLMGR service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     ACLMGR-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The ACLMGR service became standby from active mode.

Recommended Action    No action is required.

Error Message     ACLMGR-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The ACLMGR service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     ACLMGR-6-SERVICE_UP: Initialized [chars] 

Explanation    The ACLMGR service is up and ready The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     ACLMGR-6-SRVEXIT: ACLMGR Service shutting down gracefully 

Explanation    ACLMGR Service is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     ACLMGR-6-SWITCHOVER: Switching Over to other Sup. 

Explanation    The ACLMGR service has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

ACLQOS Messages

This section contains the ACLQOS messages.

ACLQOS-SLOT#-2

Error Message    ACLQOS-SLOT#-2-ACLQOS_FAILED: ACLQOS failure: [chars] 

Explanation    ACLQOS operation failed in the aclqos client

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_INBAND_INTERFACE_FAILURE: Inband interface lif 
lookup failed ([chars]) 

Explanation    Inband interface lif lookup failed

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_MALLOC_FAILED: Memory allocation failed. 
[chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-ACLQOS_OOTR: Tcam resource exhausted: [chars] 

Explanation    Tcam resources to program acls exhausted

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-2-PPF_FAILED: Database failure: [chars] 

Explanation    Database operation failed in the aclqos client

Recommended Action    No DDTS.

ACLQOS-SLOT#-3

Error Message     ACLQOS-SLOT#-3-ACLQOS_CC_INVALID: Invalid Congestion Control 
parameters 

Explanation    Invalid Congestion Control parameters

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-3-ACLQOS_PAUSE_INVALID: Invalid Pause parameters 

Explanation    Invalid Pause parameters

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-3-ACLQOS_QUEUING_ERROR: ACL/QoS queuing error: [chars] 

Explanation    Internal error in ACL/QoS queuing config

Recommended Action    No DDTS.

ACLQOS-SLOT#-4

Error Message     ACLQOS-SLOT#-4-ACLQOS_ATOMIC_ERR: [chars] 

Explanation    Tcam will be overused, please turn off atomic update

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_MATCH_ALL_MERGE_UPDATE: Warning (match_all 
merging): [chars] 

Explanation    Warning (match_all merging)

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_OVER_THRESHOLD: Tcam [dec] Bank [dec]'s usage 
has reached its threshold 

Explanation    Tcam is almost full

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_QUEUING_COS2Q_INVALID: ACL/QoS invalid queuing 
policy because of cos map change: [chars] queue [chars], interface [chars] 

Explanation    Attemped to configure an invalid queuing policy

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_QUEUING_INVALID: ACL/QoS invalid queuing 
policy: [chars] 

Explanation    Attemped to configure an invalid queuing policy

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-4-ACLQOS_UNDER_THRESHOLD: Tcam [dec] Bank [dec]'s usage 
is below the threshold now 

Explanation    Tcam's usage is below the threshold

Recommended Action    No DDTS.

ACLQOS-SLOT#-5

Error Message     ACLQOS-SLOT#-5-ACLQOS_DISRUPTIVE_IPv6_UPDATE: Disruptive update of 
IPv6 compression entries 

Explanation    Disruptive IPv6 compression entries update

Recommended Action    No DDTS.

Error Message     ACLQOS-SLOT#-5-ACLQOS_NON_ATOMIC: Non atomic ACL/QoS policy update 
done for [chars] 

Explanation    Non atomic ACL/QoS policy update was done

Recommended Action    No DDTS.

ACLTCAM Messages

This section contains the ACLTCAM messages.

ACLTCAM-2

Error Message    ACLTCAM-2-ACL_TCAM_ADJ_EXHAUSTED: ACLTCAM failed to program route for 
VSAN: [dec], SID: [chars] DID: [chars], error: [chars].

Explanation    ACLTCAM process experienced a failure while programming route for VSAN [dec] SID [chars] DID [chars] due to resource exhaustion. [chars] is the error code.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_ALMOST_FULL: TCAM close to FULL. [chars] TCAM 
Usage ([dec]/[dec]) exceeded [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_CONFIG_READ_FROM_DRIVER_FAILED: [chars] [dec], 
Error: [hex]. 

Explanation    Unable to read configuration from forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_CONFIG_WRITE_TO_DRIVER_FAILED: [chars] [dec], 
Error: [hex]. 

Explanation    Unable to write configuration to forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INCONSISTENT_DATABASE: Database found 
inconsistent. 

Explanation    Database found inconsistent.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INCONSISTENT_TCAM_CONTENTS: TCAM contents found 
inconsistent. 

Explanation    TCAM contents are found inconsistent.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INIT_FAILED: Initialization failed for forwarding 
engine ASIC: [dec], [chars] TCAM. 

Explanation    Initialization failed for forwarding engine ASIC [dec], in [chars] TCAM.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_INIT_REGIONS_FAILED: Initialization failed for 
forwarding engine ASIC: [dec], [chars] TCAM, [chars] Region. 

Explanation    Initialization of regions failed for forwarding engine ASIC [dec], in [chars] TCAM, for [chars] Region.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_MALLOC_FAILURE: Memory allocation failed for size 
[dec]. 

Explanation    Memory allocation is failed for size [dec] bytes.

Recommended Action    Restart the process.

Error Message     ACLTCAM-2-ACL_TCAM_MTS_FAILURE: MTS operation failed: [chars]. 

Explanation    MTS operation failed. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_MTS_REGISTRATION_FAILED: MTS registration failed 
for opCode: [dec]. 

Explanation    MTS registration failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_NO_ROUTE: ACLTCAM failed to get route for VSAN: 
[dec], Rewrite: [chars] DID: [chars] DID MASK: [chars], error: [hex].

Explanation    ACLTCAM process experienced a failure while getting route for VSAN [dec] Rewrite [chars] DID [chars] DID Mask [chars]. [hex] is the error code.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_NO_TCAM_LEFT: ACLTCAM resource exhausted for 
interface : [chars] 

Explanation    ACLTCAM hardware resource is completely used.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_FAILED: [chars] read from hardware 
TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: 
[chars]).

Explanation    [chars] read from hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_INVALID: Invalid([chars], value: 
[dec]) TCAM entry read from hardware TCAM (FWD-Engine: [dec], [chars] TCAM, 
Address: [dec]), Ignoring this entry.

Explanation    Invalid([chars], value: [dec]) TCAM entry from hardware TCAM(FWD-Engine: [dec], [chars] TCAM, Address: [dec]) Ignoring this entry

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PHY_TCAM_WRITE_FAILED: [chars] write to hardware 
TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: 
[chars]).

Explanation    [chars] write to hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).

Recommended Action    No action is required.

Error Message     ACLTCAM-2-ACL_TCAM_PSS_FAILURE: Failed to do PSS operation: [chars], 
reason: [hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-PSS_OPEN_FAILED: PSS open failed - [hex]. 

Explanation    Persistent database handle could not obtained for ACLTCAM. [hex] is the error.

Recommended Action    No action is required.

Error Message     ACLTCAM-2-RECONS_FAILED: Reconstruction of TCAM contents failed 
during upgrade - [hex]. 

Explanation    During non-disruptive upgrade, the ACLTCAM contents are not properly reconstructed. [hex] is the error.

Recommended Action    No action is required.

ACLTCAM-3

Error Message     ACLTCAM-3-REGISTER_FAILED: Could not register to MTS opcode [chars] 
- error [hex]. 

Explanation    ACLTCAM process could not register to the notifications mentioned by [chars]. [hex] is the error.

Recommended Action    No action is required.

ACLTCAM-4

Error Message     ACLTCAM-4-ACL_TCAM_BELOW_THRESHOLD: [chars] TCAM usage ([dec]/[dec]) 
fell below [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] fell below [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_BEYOND_THRESHOLD: [chars] TCAM usage ([dec]/[dec]) 
exceeded [dec]% fwd-eng: [dec], [chars]

Explanation    [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_INVALIDATED: Flow counter for flow: 
vsan: [dec], sid: [hex], did: [hex] with statistics: frames = %llu & bytes = %llu 
was invalidated due to: [chars]

Explanation    ACLTCAM process invalidated the flow counter for flow VSAN [dec] SID [hex] DID [hex] with collected stats of [dec] frames and [dev] bytes was invalidated because of reason [[chars]].

Recommended Action    No action is required.

Error Message     ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_VALIDATED: Flow counter for flow: 
vsan: [dec], sid: [hex], did: [hex] is now valid

Explanation    ACLTCAM process validated the flow counter for flow VSAN [dec] SID [hex] DID [hex].

Recommended Action    No action is required.

ACLTCAM-6

Error Message     ACLTCAM-6-ACL_TCAM_STATUS: Status: [chars]. 

Explanation    ACLTCAM status is reported as: [chars].

Recommended Action    No action is required.

ACL Messages

This section contains the ACL messages.

ACL-2

Error Message    ACL-2-ACL_HA_FAILURE: Failed to do high availability operation: 
[chars]. 

Explanation    Failed to do high availability operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_INIT_FAILED: Initialization failed for ACL: [chars], 
reason: [hex]. 

Explanation    Initialization failed for ACL due to [chars], reason: [hex].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_LINECARD_STATUS: Status from linecard: [dec], for module: 
[chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], 
restart count: [dec].

Explanation    Status from linecard: [dec], for module: [chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], restart count: [dec].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_MTS_FAILURE: Failed to do MTS operation: [chars]. 

Explanation    Failed to do MTS operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_MTS_REGISTRATION_FAILED: MTS options setting to [hex] 
failed for opCode: [dec]. 

Explanation    MTS options setting to [hex] failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PENDING_MSG_ARR_FULL: ACL Upgrade Pending Messages Array is 
Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]

Explanation    ACL Upgrade Pending Messages Array is Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PSS_FAILURE: Failed to do PSS operation: [chars], reason: 
[hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec]. 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.

Recommended Action    No action is required.

Error Message     ACL-2-ACL_RUNTIME_FAILURE: [chars] [dec], Error: [hex] 

Explanation    ACL runtime failure is reported as [chars] [dec], reason: [hex].

Recommended Action    No action is required.

Error Message     ACL-2-ACL_TCAM_FAILURE: Failed to do TCAM operation: [chars]. 

Explanation    Failed to do TCAM operation. [chars] is the reason.

Recommended Action    No action is required.

ACL-4

Error Message     ACL-4-ACL_WARNING: [chars] [dec] 

Explanation    ACL warning messages is reported as [chars] [dec].

Recommended Action    No action is required.

ACL-5

Error Message     ACL-5-ACL_ADJ_SHARING_STATUS: Successfully completed [chars] on 
Generation 2 linecards. 

Explanation    Successfully completed the command \[chars]\ on Generation 2 linecards.

Recommended Action    No action is required.

ACL-6

Error Message     ACL-6-ACL_DIAG_EVENT_STATUS: [chars] [hex]. 

Explanation    ACL system health management event status is reported as [chars] [hex].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_E_PORT_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL xEport event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_FCC_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL FCC event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_LINECARD_EVENT_STATUS: [chars] [hex]. 

Explanation    ACL linecard event status is reported as [chars] [dec].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_MCAST_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL multicast event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_NX_PORT_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL Nx Port event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_PORT_MODE_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL portmode event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_RUNTIME_STATUS: [chars] [dec] 

Explanation    ACL runtime status is reported as [chars] [dec].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_SPAN_DEST_CONFIG_STATUS: [chars] [chars]. 

Explanation    ACL SPAN destination config event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_SPAN_SRC_CONFIG_STATUS: [chars] [chars]. 

Explanation    ACL SPAN source config event status is reported as [chars] [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_STATUS: ACL Status: [chars]. 

Explanation    ACL status is reported as [chars].

Recommended Action    No action is required.

Error Message     ACL-6-ACL_UPDATE_SSRAM_QOS_EVENT_STATUS: [chars] [chars]. 

Explanation    ACL update SSRAM for QoS event status is reported as [chars] [chars].

Recommended Action    No action is required.

ASCII-CFG Messages

This section contains the ASCII-CFG messages.

ASCII-CFG-2

Error Message    ASCII-CFG-2-ACFG_CONFIGURATION_APPLY_ERROR: Error encountered while 
Ascii configuration was being applied. Please use show startup-config log to view 
details

Explanation    At least one command failed while Ascii configuration was being applied

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_LIB_INVOKE_ERR: Ascii config library invocation 
error: [chars] 

Explanation    Error encountered while library function was being invoked to display Ascii configuration

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_OPER_FAIL: Operation failed because of [chars] 

Explanation    Operation failed

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_ROLLBACK_FAILED: Rollback to checkpoint [chars] 
Failed, Going to undo the changes (atomic option) 

Explanation    Rollback operation failed for atomic option

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_ROLLBACK_UNDO_FAILED: Undo failed for atomic 
Rollback, Please correct the error manually and retry rollback 

Explanation    Undoing the rollback changes (for atomic behavior) Failed

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-ACFG_SYSLOG_INIT_FAILED: Ascii config Syslog Init Error 

Explanation    Error encountered while Initializing Syslog for Ascii Config

Recommended Action    No action is required.

Error Message     ASCII-CFG-2-PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

ASCII-CFG-3

Error Message     ASCII-CFG-3-ACFG_MTSERROR: [chars] 

Explanation    Ascii-cfg-server (rollback process) encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

ASCII-CFG-6

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_CLEAR_DATABASE: cleared all the 
configuration checkpoints 

Explanation    Cleared all the configuration checkpoints

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_CREATED: Created configuration 
checkpoint [chars] 

Explanation    Created configuration checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_CHECKPOINT_DELETED: Deleted configuration 
checkpoint [chars] 

Explanation    Deleted configuration checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_MAX_CHECKPOINTS: Maximum no of checpoints reached, 
Removing the oldest checkpoint 

Explanation    Maximum no.of checkpoints reached, removing the oldest checkpoint

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_ATOMIC: Performing configuration rollback 
to checkpoint [chars] (with atomic option) 

Explanation    Performing configuration rollback with atomic option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_BEST: Performing configuration rollback to 
checkpoint [chars] (with best-effort option) 

Explanation    Performing configuration rollback with best-effort option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-ACFG_ROLLBACK_FIRST_ERR: Performing configuration 
rollback to checkpoint [chars] (with stop-at-first failure option) 

Explanation    Performing configuration rollback with stop-at-first-failure option

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-INFORMATION: [chars] 

Explanation    An event happend that affects Acfg-Rollback. [chars] indicates the event

Recommended Action    No action is required.

Error Message     ASCII-CFG-6-PSS_ERR: [chars] 

Explanation    An error occurred during an Acfg PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BIOS DAEMON Messages

This section contains the BIOS DAEMON messages.

BIOS DAEMON-2

Error Message    BIOS_DAEMON-2-BIOS_DAEMON_FLASH_WARNING: Flash chip not supported by 
running image. Skipping bios upgrade. 

Explanation    BIOS CHIP NOT SUPPORTED

Recommended Action    No action is required.

Error Message     BIOS_DAEMON-2-BIOS_DAEMON_PRI_BOOT_FAIL: Primary BIOS is corrupted or 
un-bootable 

Explanation    PRIMARY BIOS CORRUPTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     BIOS_DAEMON-2-BIOS_DAEMON_SUP_ERROR: BIOS Sector ([dec]) is write 
protected 

Explanation    BIOS WRITE PROTECTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BIOS_DAEMON-SLOT#-2

Error Message     BIOS_DAEMON-SLOT#-2-BIOS_DAEMON_LC_ERROR: BIOS Sector ([dec]) is 
write protected 

Explanation    BIOS WRITE PROTECTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     BIOS_DAEMON-SLOT#-2-BIOS_DAEMON_LC_PRI_BOOT_FAIL: Primary BIOS is 
corrupted or un-bootable 

Explanation    PRIMARY BIOS CORRUPTED

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

BOOTUP TEST Messages

This section contains the BOOTUP TEST messages.

BOOTUP TEST-2

Error Message    BOOTUP_TEST-2-EOBC_FAIL: Module [dec] has failed test [chars] on EOBC 
due to error [chars] 

Explanation    Online diagnostics EOBC test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-EOBC_SKIP: Module [dec] has failed test [chars] on EOBC 
due to error [chars] 

Explanation    Online diagnostics ManagementPort test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-MGMT_PORT_FAIL: Module [dec] has failed test [chars] on 
Management Port due to error [chars] 

Explanation    Online diagnostics ManagementPort test has failed

Recommended Action    No action is required.

Error Message     BOOTUP_TEST-2-MGMT_PORT_SKIP: Module [dec] has skipped test [chars] 
on Management Port due to error [chars] 

Explanation    Online diagnostics ManagementPort test is skipped

Recommended Action    No action is required.

BOOTVAR Messages

This section contains the BOOTVAR messages.

BOOTVAR-2

Error Message    BOOTVAR-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate memory.

Recommended Action    Check if the system is low on memory, if so reset the switch.

Error Message     BOOTVAR-2-AUTOCOPY_FAILED: Autocopy of file [chars] to standby 
failed. [chars] (Error-id: [hex]) 

Explanation    The image deemed to be copied to standby via the auto-copy feature failed.

Recommended Action    Check error id for specified reason.

Error Message     BOOTVAR-2-AUTOSYNC_FAILED: Image autosync failed. Reason: [chars] 
([hex]) 

Explanation    Image synchronization failed.

Recommended Action    Check that there is enough space on the flash, as well as system high availability status.

Error Message     BOOTVAR-2-CONFIG_ERROR: Failed to update boot configuration 

Explanation    An error has occurred during the update of the boot configuration files

Recommended Action    Check that there is enough space on the flash, show boot to check the configured image names, show loader internal configuration to compare them with the current bootloader configuration, if they are not coherent do write erase and retry to save the configuration.

Error Message     BOOTVAR-2-IMAGE_NOT_COMPATIBLE: Warning: image [chars] is not 
compatible with the current platform in SUP [dec] 

Explanation    The input image name is not compatible with the current platform.

Recommended Action    Make sure a right image is specified before reboot.

BOOTVAR-3

Error Message     BOOTVAR-3-AUTOCOPY_FAILED_STANDBY_FULL: Autocopy of file [chars] to 
standby failed due to not enough disk space on standby

Explanation    There is not enough disk space on the standby for the file to be copied.

Recommended Action    Clear space on the standby disk.

Error Message     BOOTVAR-3-INIT_FAILED: Initialization failed: Component [chars] 

Explanation    The service failed to start The failure occurs during initialization of the component [chars].

Recommended Action    Show processes to check the status of the other processes, pay attention to the specified component.

Error Message     BOOTVAR-3-LOAD_VERIFY_LIB_FAILED: Fetching library [chars] failed, 
reason=[chars] 

Explanation    Failed to load bootvar specified verification library.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-MODULE_LOCK_FAIL: Unable to get module lock, please don't 
reload <error-id:[hex]> 

Explanation    Unable to acquire modlock to prevent user to reload during auto-sync.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-NEIGHBOR_REJECT_AUTOCOPY: auto-copy failed - not supported 
by neighbor supervisor. 

Explanation    Standby supervisor does not support auto-copy, thus failed.

Recommended Action    No action is required.

Error Message     BOOTVAR-3-VERIFY_FAILED: Image [chars] for bootvar [chars] 
verification failed, reason=[chars] 

Explanation    The image set for this bootvar has failed the verification process, this is just a warning.

Recommended Action    Check reason to determine actions.

BOOTVAR-5

Error Message     BOOTVAR-5-AUTOCOPY_SUCCEED: auto-copy of file [chars] to standby 
supervisor succeed 

Explanation    Auto copy of the file succeed, image integrity verified by standby.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-AUTOCOPY_VERIFY_SEND_FAILED: Unable to ask standby to 
verify file [chars], error = [hex] 

Explanation    Upon copied the image to standby, failed to send message to ask standby to verify integrity.

Recommended Action    Turn auto-copy off and back on.

Error Message     BOOTVAR-5-AUTOSYNC_DONE: Image autosync done 

Explanation    The image synchronization done successfully.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-AUTOSYNC_REBOOT: Rebooting standby after successful 
autosync 

Explanation    Image autosync has been successful, resetting the standby supervisor to load the new image.

Recommended Action    Check that the standby sup reloads correctly.

Error Message     BOOTVAR-5-AUTOSYNC_START: Starting image autosync. Please wait until 
completion... 

Explanation    The standby-sup has requested the sync of the current image.

Recommended Action    No action is required.

Error Message     BOOTVAR-5-IMAGE_NOTEXISTS: Warning: image [chars] doesn't exist on 
sup[dec] 

Explanation    The input image name doesn't exist on the specified supervisor.

Recommended Action    Check whether the input image name you entered exists and make sure that you have the image on the flash before reboot.

Error Message     BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor 
supervisor, starting... 

Explanation    Info log reporting standby's support of auto-copy. Auto-copy is being started.

Recommended Action    No action is required.

BOOTVAR-6

Error Message     BOOTVAR-6-ALREADY_IN_SYNC: Image already in sync 

Explanation    No need to update the image on the standby-sup.

Recommended Action    No action is required.

Error Message     BOOTVAR-6-AUTOCOPY_DID_NOT_START: Autocopy of file [chars] to standby 
did not start. [chars] (Error-id: [hex])

Explanation    Autocopy of the file did not start as the remote copy location does not exist

Recommended Action    No action is required.

Error Message     BOOTVAR-6-CONFIG_UPDATED: Boot configuration updated 

Explanation    The boot-loader configuration files have been successfully updated.

Recommended Action    No action is required.

Error Message     BOOTVAR-6-STARTING: Boot configuration initialized 

Explanation    The service has successfully started.

Recommended Action    No action is required.

CALLHOME Messages

This section contains the CALLHOME messages.

CALLHOME-2

Error Message    CALLHOME-2-EVENT: [chars] 

Explanation    Callhome event [chars] occurred.

Recommended Action    If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error

Error Message     CALLHOME-2-PROGRAM_EXIT: callhome process ending: [chars] 

Explanation    Callhome process is exiting with reason [chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CALLHOME-3

Error Message     CALLHOME-3-CALLHOME_CFS_MERGE_OPERATION_FAILED: [chars] 

Explanation    [chars1]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CALLHOME-3-CALLHOME_CFS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CALLHOME-3-CALLHOME_MAX_ALERT_MSG: [chars] 

Explanation    [chars]

Recommended Action    Please check the reason for the generation of the callhome messages and rectify the problem

Error Message     CALLHOME-3-EVENT_PROCESS_ERROR: error in processing callhome event 
[chars] reason:[chars] 

Explanation    Error in processing callhome event [chars] reason:[chars]

Recommended Action    Please check your callhome configuration for proper configuration. Please check SMTP server address, email addresses for destination profiles and enable status of callhome. Use show callhome commands for displaying configuration.

Error Message     CALLHOME-3-MESSAGE_SIZE_EXCEED: message size for callhome 
alert:[chars] exceeds maximum limit for destination profile:[chars]

Explanation    Message size for callhome alert:[chars] exceeds maximum limit for destination profile:[chars]

Recommended Action    Please check the maximum message size for the destination profile under question. Increase it if possible to match the maximum limit allowed by your email destinations.

CALLHOME-6

Error Message     CALLHOME-6-NONCRIT_EVENT: [chars] 

Explanation    Non-critical Callhome event [chars] occurred.

Recommended Action    If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error.

CDP Messages

This section contains the CDP messages.

CDP-2

Error Message    CDP-2-INITFAIL: CDP Daemon Initialization failed: [chars] 

Explanation    CDP Daemon Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

CDP-3

Error Message     CDP-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    CDP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     CDP-3-GENERROR: [chars] 

Explanation    CDP Daemon encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     CDP-3-MCASTBINDFAIL: Failed to bind for CDP multicast address on 
interface [hex] - [chars]

Explanation    An attempt to register for packets destined to the CDP multicast address failed. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-MTSERROR: [chars] 

Explanation    CDP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     CDP-3-PKTRECVFAIL: Failed to receive packet - [chars] 

Explanation    Failed to receive packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-PKTSENDFAIL: Failed to send packet, interface [hex] - [chars] 

Explanation    Failed to send packet. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-PSSERROR: [chars] 

Explanation    CDP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     CDP-3-SOCKBINDFAIL: Failed to bind to raw socket, interface [hex] - 
[chars] 

Explanation    Failed to bind to raw socket. [dec] identifies the interface [char] identifies the reason.

Recommended Action    No action is required.

Error Message     CDP-3-SOCKOPENFAIL: Failed to open socket for receiving raw 802_2 
packets - [chars] 

Explanation    An attempt to open a socket for receiving raw 802_2 packets failed. [char] identifies the reason.

Recommended Action    No action is required.

CDP-4

Error Message     CDP-4-DUPLEX_MISMATCH: Duplex mismatch discovered on [chars], with 
[chars] 

Explanation    Duplex mismatch discovered from the received cdp packet This is a warning message.

Recommended Action    No action is required.

Error Message     CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on 
[chars]([dec]), with [chars]([dec]) 

Explanation    Native VLAN mismatch discovered This is a warning message.

Recommended Action    No action is required.

CDP-5

Error Message     CDP-5-DISABLED: CDP is disabled 

Explanation    CDP is disabled on the device.

Recommended Action    No action is required.

Error Message     CDP-5-ENABLED: CDP is enabled 

Explanation    CDP is enabled on the device.

Recommended Action    No action is required.

CDP-6

Error Message     CDP-6-CDPDUP: CDP Daemon Up. 

Explanation    CDP Daemon was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-CDPEXIT: CDP Daemon shutting down gracefully. 

Explanation    CDP Daemon is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-NEIGHBOR_ADDED: Device [chars] discovered of type [chars] with 
port [chars] on incoming port [chars] with ip addr [chars] and mgmt ip [chars]

Explanation    Discovered a neighbor device. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-NEIGHBOR_REMOVED: CDP Neighbor [chars] on port [chars] has been 
removed 

Explanation    Deleted a neighbor device. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTDISABLE: CDP disabled on port [chars] 

Explanation    CDP was disabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTDOWN: A CDP enabled port [chars] went down. 

Explanation    A CDP enabled port became un-operational. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTENABLE: CDP enabled on port [chars] 

Explanation    CDP was enabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

Error Message     CDP-6-PORTUP: A CDP enabled port [chars] came up. 

Explanation    A CDP enabled port became operational. [chars] is the interface-ID string that identifies the port. This is an informational message.

Recommended Action    No action is required.

CERT_ENROLL Messages

This section contains the CERT_ENROLL messages.

CERT_ENROLL-2

Error Message    CERT_ENROLL-2-CERT_EN_PROGRAM_EXIT: cert_enroll daemon exiting: 
[chars] 

Explanation    Cert_enroll daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CERT_ENROLL-3

Error Message     CERT_ENROLL-3-CERT_EN_ERROR_MESSAGE: [chars] 

Explanation    CERT_ENROLL Error Message

Recommended Action    No action is required.

Error Message     CERT_ENROLL-3-CERT_EN_FIPS_MODE_INIT_ERROR: Could not initialize FIPS 
mode : [chars] 

Explanation    FIPS mode initialization error

Recommended Action    No action is required.

CERT_ENROLL-6

Error Message     CERT_ENROLL-6-CERT_EN_MESSAGE: [chars] 

Explanation    CERT_ENROLL Message

Recommended Action    No action is required.

CFS Messages

This section contains the CFS messages.

CFS-2

Error Message    CFS-2-CFS_REJECT: CFS reject: [chars]: Switch WWN [chars], ip [chars], 
reason [chars] 

Explanation    CFS reject: [chars] Switch WWN [chars], ip [chars], reason [chars]

Recommended Action    No action is required.

Error Message     CFS-2-EXITING: Exit reason: [chars] 

Explanation    The CFS service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     CFS-2-GENERAL_ERROR: [chars] 

Explanation    The CFS service has encountered an critical error. The description of error is [str.]

Recommended Action    No action is required.

Error Message     CFS-2-INITFAIL: CFS Service Init failed: [chars] 

Explanation    CFS Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     CFS-2-LOCK_FAILED: lock failed for sap [dec] due to internal error. 

Explanation    Lock failed due to Unrestricted uncoordinated count is out of sync for sap [dec]

Recommended Action    To recover from this state run command 'cfs internal decrement-unrestricted <app-sap>'

Error Message     CFS-2-MALLOC_ERROR: Size [dec] bytes 

Explanation    The CFS service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     CFS-2-MTS_REJECT: Verification failed reject MTS message SAP 
[dec]:RR-token [hex] 

Explanation    This MTS message could have been posted by the previous active running pre 3.x; MTS structure has changed since then hence ignore the MTS message, Source SAP [dec]; RR-token [hex]

Recommended Action    No action is required.

Error Message     CFS-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The CFS service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     CFS-2-VDC_MGR_FAIL: Failed to get a valid switch mac from VDC Manager: 
[chars] 

Explanation    VDC manager did not respond with a proper MAC address. It could have been because of a timeout in MTS received

Recommended Action    No action is required.

CFS-3

Error Message     CFS-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    CFS Service is out of dynamic memory. [chars] specifies the context where the failure occured

Recommended Action    No action is required.

Error Message     CFS-3-APP_MERGE_FAILED: Merge failed for app [chars], local switch 
wwn [chars], remote switch wwn [chars].Please check 'show cfs merge status name 
[chars]' for more information

Explanation    The CFS service has detected a merge failure.

Recommended Action    No action is required.

Error Message     CFS-3-CFS_PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The CFS service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     CFS-3-DBERROR: [chars] 

Explanation    CFS Service encountered a database error. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-FAILURE_RESPONSE: [chars] [hex] 

Explanation    CFS Service failed to get response [chars][hex] specify the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-FIPS_TEST_FAILED: FIPS compliance test failed 

Explanation    FIPS compliance test failed

Recommended Action    No action is required.

Error Message     CFS-3-GENERROR: [chars] 

Explanation    CFS Service encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     CFS-3-LICERR: [chars] 

Explanation    CFS Service failed to get license.

Recommended Action    No action is required.

Error Message     CFS-3-MERGE_FAILED: Merge failed for app [chars], local switch wwn 
[chars],ip [chars], remote switch wwn [chars], ip [chars]

Explanation    The CFS service has detected a merge failure.

Recommended Action    No action is required.

Error Message     CFS-3-MTSERROR: [chars] 

Explanation    CFS Service encountered an MTS error. [chars] specifies the context where the error occured.

Recommended Action    No action is required.

Error Message     CFS-3-PSSERROR: [chars] 

Explanation    CFS Service encountered a PSS error. [chars] specifies the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-TIMEOUT_ERROR: [chars] [hex] 

Explanation    CFS Service encountered a timeout [chars][hex] specify the context where the failure occured.

Recommended Action    No action is required.

Error Message     CFS-3-UNKNOWN_MSG: Recvd. from Node=[dec] SAP=[dec] 

Explanation    The CFS service has received an unknown message from [dec]].[dec]. This information is for debugging only.

Recommended Action    No action is required.

CFS-4

Error Message     CFS-4-LICEXP: [chars] 

Explanation    CFS Service license is going to expire. [chars] gives the expected time of expiry

Recommended Action    No action is required.

Error Message     CFS-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the CFS service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

CFS-6

Error Message     CFS-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The CFS service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     CFS-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The CFS service became standby from active mode.

Recommended Action    No action is required.

Error Message     CFS-6-EXCESSIVE_DELAY: [chars] 

Explanation    Excessive time taken for a processing event. The description of the event is [str.]

Recommended Action    No action is required.

Error Message     CFS-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The CFS service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     CFS-6-GENERAL_EVENT: [chars] 

Explanation    The CFS service has generated an important event. The description of the event is [str.]

Recommended Action    No action is required.

Error Message     CFS-6-INVALID_CHECKSUM: Received packet from peer on if-index([hex]) 
with corrupted checksum 

Explanation    This could be because of errors in the link

Recommended Action    No action is required.

Error Message     CFS-6-INVALID_IF_INDEX: Received packet on if-index([hex]) which is 
not recognized by CFS 

Explanation    The if-index does not match with the if-index used in discovery or we might have already recieved an adjacency cleanup message for this if-index. Check if the if-index is that of the port-channel or a physical if-index

Recommended Action    No action is required.

Error Message     CFS-6-LOGICAL_DISTRIBUTION_INFO: vsan [dec], source wwn [chars], ip 
[chars] app-id [dec], session-id [dec], user [chars], [chars] 

Explanation    Vsan [dec], source wwn [chars], ip [chars], app-id [dec], user [chars], event [chars]

Recommended Action    No action is required.

Error Message     CFS-6-PHY_DISTRIBUTION_INFO: source wwn [chars], ip [chars], app-id 
[dec], session-id [dec], user [chars], [chars] 

Explanation    Source wwn [chars], ip [chars], app-id [dec], session-id [dec], user [chars], event [chars]

Recommended Action    No action is required.

Error Message     CFS-6-PSS_CREATED: [chars] PSS Created 

Explanation    One of the persistent information database of CFS service has been recreated

Recommended Action    No action is required.

Error Message     CFS-6-PSS_DESTROYED: [chars] PSS Destroyed 

Explanation    One of the persistent information databases of CFS Service has been intentionally destroyed and would be recreated.

Recommended Action    No action is required.

Error Message     CFS-6-REGION_CTX_REMOVED: Region info is deleted for [chars] 

Explanation    [chars] is in logical scope. Regions are supported only physical scope applications

Recommended Action    No action is required.

Error Message     CFS-6-SERVICE_UP: Initialized [chars] 

Explanation    The CFS service is up and ready to accept client requests The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     CFS-6-SRVCREATED: CFS Service created 

Explanation    CFS Service was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     CFS-6-SRVEXIT: CFS Service shutting down gracefully 

Explanation    CFS Service is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     CFS-6-SWITCHOVER: Switching Over to other Sup. 

Explanation    The CFS service has successfully switched over to the standby supervisor card.

Recommended Action    No action is required.

CIMSRVPROV Messages

This section contains the CIMSRVPROV messages.

CIMSRVPROV-2

Error Message    CIMSRVPROV-2-CIM_SYSLOG_EXIT: Message:[chars] errcode:[dec] 

Explanation    Exit due to critical error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-2-CIM_SYSLOG_PSS_SNAPSHOT_ERR: Source URI:[chars] 
Destination URI:[chars] errcode:[dec] 

Explanation    PSS snapshot error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-2-CIM_SYSLOG_SDWRAP_ERR: Description:[chars] 
errcode:[dec] 

Explanation    Debug infrastructure error

Recommended Action    No action is required.

CIMSRVPROV-3

Error Message     CIMSRVPROV-3-CIM_SYSLOG_COPY_CONFIG_ERR: Message:[chars] URI:[chars] 
errcode:[dec] 

Explanation    Copy running startup error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_FILE_ERR: Purpose:[chars] Filename:[chars] 
errcode:[dec] 

Explanation    File handling error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_MTS_ERR: message [chars] 

Explanation    MTS message handling error

Recommended Action    No action is required.

Error Message     CIMSRVPROV-3-CIM_SYSLOG_PSS_ERR: Purpose:[chars] URI:[chars] 
errcode:[dec] 

Explanation    PSS handling error

Recommended Action    No action is required.

CIMSRVPROV-6

Error Message     CIMSRVPROV-6-LOG_CIM_CERTIFICATE_CLEARED: Cleared certificate 
[chars] 

Explanation    Cleared a certificate named [chars].

Recommended Action    No action is required.

Error Message     CIMSRVPROV-6-LOG_CIM_CERTIFICATE_INSTALLED: Installed certificate 
[chars] 

Explanation    Installed a certificate named [chars].

Recommended Action    No action is required.

CLIS Messages

This section contains the CLIS messages.

CLIS-5

Error Message    CLIS-5-CLIS_SYSLOG_CMD_REMOVED: Command deleted from the NVDB: [chars] 

Explanation    Command removal due to configuration change

Recommended Action    No action is required.

CLOUD Messages

This section contains the CLOUD messages.

CLOUD-2

Error Message    CLOUD-2-PROGRAM_EXIT: cloud-discovery process ending: [chars] 

Explanation    Cloud-discovery process is exiting with reason [chars].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

CLOUD-3

Error Message     CLOUD-3-CLOUD_CFS_MERGE_OPERATION_FAILED: [chars] 

Explanation    [chars1]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CLOUD-3-CLOUD_CFS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the cfs operation and rectify the problem

Error Message     CLOUD-3-CLOUD_FEATURE_MANAGER_ERROR: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for error using feature manager and rectify the problem

Error Message     CLOUD-3-CLOUD_PSS_OPERATION_FAILED: [chars] : [chars] 

Explanation    [chars1] [chars2]

Recommended Action    Please check the reason for the failure of the pss operation and rectify the problem

CLOUD-6

Error Message     CLOUD-6-CLOUD_DISCOVERY_DONE: discovery over 

Explanation    Cloud-discovery started

Recommended Action    Check cloud membership

Error Message     CLOUD-6-CLOUD_DISCOVERY_STARTED: [chars] discovery started 

Explanation    Cloud-discovery started

Recommended Action    Check cloud-discovery status after sometime

CLUSTER Messages

This section contains the CLUSTER messages.

CLUSTER-2

Error Message    CLUSTER-2-CLUSTER_CAP_ADD_FAIL: Failed to add cluster capability [dec] 

Explanation    Cluster capability addition failed

Recommended Action    No action is required.

Error Message     CLUSTER-2-CLUSTER_CAP_DEL_FAIL: Failed to delete cluster capability 
[dec] 

Explanation    Cluster capability deletion failed

Recommended Action    No action is required.

CMPPROXY Messages

This section contains the CMPPROXY messages.

CMPPROXY-2

Error Message    CMPPROXY-2-LOG_CMP_IS_NOT_UP: Connectivity Management processor (on 
module [dec]) did not come up 

Explanation    Connectivity Management processor is not sending heartbeats on this module

Recommended Action    No action is required.

Error Message     CMPPROXY-2-LOG_CMP_UP: Connectivity Management processor(on module 
[dec]) is now UP 

Explanation    Connectivity Management processor has come up and is exchanging heartbeats with CP on this SUP slot

Recommended Action    No action is required.

Error Message     CMPPROXY-2-LOG_CMP_WENT_DOWN: Connectivity Management processor (on 
module [dec]) went DOWN 

Explanation    Connectivity Management processor has either gone down or is not sending heartbeats for a long time

Recommended Action    No action is required.

CMPPROXY-5

Error Message     CMPPROXY-5-LOG_CMP_AAA_FAILURE: Authentication failed for a login 
from CMP (on module [dec]) 

Explanation    A login attempt has been denied access from Connectivity management processor (CMP) as authentication did not succeed

Recommended Action    No action is required.

Error Message     CMPPROXY-5-MALLOC_FAILURE: Memory allocation failure 

Explanation    Memory allocation in a call to malloc/calloc has failed.

Recommended Action    No action is required.

CMPPROXY-6

Error Message     CMPPROXY-6-LOG_CMP_AAA_SUCCESS: Authentication succeeded for a login 
from CMP (on module [dec]) 

Explanation    A login attempt has succeeded from Connectivity management processor (CMP) in getting access as AAA succeeded

Recommended Action    No action is required.

COPP Messages

This section contains the COPP messages.

COPP-2

Error Message    COPP-2-COPP_INIT_FAIL: CoPP Initialization failed: [chars] 

Explanation    CoPP Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-2-COPP_MTS_FAIL: Failed to do MTS operation: [chars] 

Explanation    Failed to do MTS operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

COPP-3

Error Message     COPP-3-COPP_ALLOC_FAIL: Memory allocation failure: [chars] 

Explanation    Failed to alloc required memory. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-3-COPP_PPF_FAIL: Error during PPF operation: [chars] 

Explanation    Failed to do PPF operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     COPP-3-COPP_PSS_FAIL: Error during PSS operation: [chars] 

Explanation    Failed to do PSS operation. [chars] explains the reason for the failure.

Recommended Action    No action is required.

COPP-5

Error Message     COPP-5-COPP_DISABLED: COPP Disabled 

Explanation    COPP Service Disabled

Recommended Action    No action is required.

Error Message     COPP-5-COPP_ENABLED: COPP Enabled 

Explanation    COPP Service nabled

Recommended Action    No action is required.

Error Message     COPP-5-COPP_INIT: COPP initialized 

Explanation    COPP Service Initialized

Recommended Action    No action is required.

COPP-6

Error Message     COPP-6-COPP_POLICY_ATTACHED: CoPP policy has been attached to control 
plane interface. 

Explanation    CoPP policy has been attached to control plane interface.

Recommended Action    No action is required.

Error Message     COPP-6-COPP_POLICY_DETACHED: CoPP policy has been detached from 
control plane interface. 

Explanation    CoPP policy has been detached from control plane interface.

Recommended Action    No action is required.

CORE-DMON Messages

This section contains the CORE-DMON messages.

CORE-DMON-2

Error Message     CORE-DMON-2-MODULE_COREDUMP_DONE: kernel coredump completed on 
module:[dec] 

Explanation    Kernel coredump finishing on a module

Recommended Action    No action is required.

Error Message     CORE-DMON-2-MODULE_COREDUMP_STARTED: kernel coredump started on 
module:[dec] 

Explanation    Kernel coredump starting on a module

Recommended Action    No action is required.

CORE-DMON-3

Error Message     CORE-DMON-3-NO_SPACE: Failed to save core file [chars]. Try removing 
existing core files. 

Explanation    Not enough space to save new core files

Recommended Action    No action is required.

CPPA_MGR Messages

This section contains the CPPA_MGR messages.

CPPA_MGR-3

Error Message    CPPA_MGR-3-ENABLE_VB_FAILURE: Virtual service blade [dec] could not be 
[chars]. Error: [chars] 

Explanation    The requested virtual blade operation could not be completed

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-NO_HB_REBOOT: No heartbeat from agent service. Nexus1010 
is rebooted 

Explanation    No heartbeat from agent service. Nexus1010 is rebooted

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-REMOTE_ILO_REBOOT: Remote mgmt feature rebooted other 
Nexus1010 using ILO 

Explanation    Remote mgmt feature rebooted other Nexus1010 using ILO

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-RESTORE_FAILURE: Agent version could not be restored to 
make versions match 

Explanation    The previous agent version could not be restored. System needs to be reinstalled to recover

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-SOME_PNIC_FAILURE: Not all the Nexus1010 physical NICs are 
detected. Check for failure 

Explanation    Not all the physical NICs are detected. Check for failure

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-UNDO_WRITE_ERASE: Undo Write Erase: [chars] 

Explanation    The software undo write erase result:

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-UPGRADE_FAILED: Upgrade failed: [chars] 

Explanation    The software upgrade could not complete because of errors

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-VERSION_MISMATCH: Agent version mismatch detected. System 
will be reloaded 

Explanation    The cppa_mgr and the underlying agent are not running the same software version

Recommended Action    No action is required.

Error Message     CPPA_MGR-3-WRITE_ERASE: Write Erase: [chars] 

Explanation    The software write erase result:

Recommended Action    No action is required.

CPPA_MGR-5

Error Message     CPPA_MGR-5-REMOTE_VB_HA_FAILURE: Operation failed in standby for 
virtual service blade [dec]: [chars] 

Explanation    An error occurred while processing a command from active at standby

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-REMOTE_VB_IMG_FAILURE: Could not verify image in standby 
for virtual service blade [dec] creation: [chars] 

Explanation    An error occurred while processing image required for vb creation at standby

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-UPGRADE_COMPLETE: Upgrade completed successfully 

Explanation    The software upgrade completed with no errors

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-UPGRADE_START: Upgrade started. Image: [chars] 

Explanation    A software upgrade has been initiated by the user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_DEPLOYED: Virtual service blade [chars] deployed 

Explanation    Virtual service blade deployed on nexus1010 successfully

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_REMOVED: Virtual service blade [chars] removed 

Explanation    Virtual service blade removed by user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_RESTARTED: Virtual service blade [chars] restarted 

Explanation    Virtual service blade restarted by user

Recommended Action    No action is required.

Error Message     CPPA_MGR-5-VB_SHUT: Virtual service blade [chars] moved into shut 
state 

Explanation    Virtual service blade shut by user

Recommended Action    No action is required.

CREDITMON Messages

This section contains the CREDITMON messages.

CREDITMON-SLOT#-2

Error Message    CREDITMON-SLOT#-2-SYSERR_CREDITMON_APP_EXITED: [chars] 

Explanation    Credit Monitor application exited

Recommended Action    No action is required.

Error Message     CREDITMON-SLOT#-2-SYSERR_CREDITMON_MTS_INIT_ERR: [chars] 

Explanation    Credit Monitor error binding to MTS

Recommended Action    No action is required.

CTS Messages

This section contains the CTS messages.

CTS-2

Error Message     CTS-2-CTS_AUTHENT_FAILURE: CTS Authentication failure on Port [chars] 
(CTS Failure Reason: [chars] [chars]) 

Explanation    Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port

Recommended Action    No action is required.

Error Message     CTS-2-DBG_INIT_FAILED: Debug Infrastructure Initialization failed ( 
[chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an E_Port 
failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the FC-2 E-Port infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an F_Port 
failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the FC-2 F-Port infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown FC-2 
frame on [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-FSMU_INIT_FAILED: State Machine Infrastructure Initialization 
failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-IPC_INIT_FAILED: IPC (Inter Process Communication) 
Initialization failed ( [chars] ) 

Explanation    CTS Manager has been unable to initialize with the IPC infrastructure.

Recommended Action    No action is required.

Error Message     CTS-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service 
exiting 

Explanation    License of [chars] is unavailable. Service will exit now

Recommended Action    Please install the license file to continue using the feature.

Error Message     CTS-2-MEM_FAILED: Memory operations failed File: [chars] Line [dec] 
for size [hex] bytes 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-POST_INIT_FAILED: Post-Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed ( 
[chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_ENFORCEMENT_FAILED: RBACL enforcement failed on [chars] 
[dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_LC_INSERT_FAILED: RBACL programming failed for inserted 
module [dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_TCAM_SPACE_NOT_ENOUGH: Not enough free space left on TCAM 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_UNABLE_PARSE_ACE: Unable to parse RBACL ACE substring: 
[chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     CTS-2-RBACL_UPDATE_FAILED: Failed to [chars] RBACL [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

CTS-3

Error Message     CTS-3-DOT1X_AUTHC_FAILED: DOT1X authentication failed on port: 
[chars] 

Explanation    DOT1X authentication failed on the port

Recommended Action    No action is required.

CTS-5

Error Message     CTS-5-CTS_IP_SGT_MAP_UPDATE: [chars] assigned SGT [dec] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

DEBUGPROXY Messages

This section contains the DEBUGPROXY messages.

DEBUGPROXY-6

Error Message    DEBUGPROXY-6-SSM_DEBUG_PROXY_COMMON: SSM debug proxy [chars] [dec] 

Explanation    General SSM debug proxy information

Recommended Action    No action is required.

DEVICE-ALIAS Messages

This section contains the DEVICE-ALIAS messages.

DEVICE-ALIAS-2

Error Message    DEVICE-ALIAS-2-ALLOC_FAILED: Memory allocation failed for size:[dec] 
type:[dec] 

Explanation    Memory allocation failed for size [dec] type [dec]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-2-INIT_FAILED: [chars] 

Explanation    An error occurred during initialization. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DEVICE-ALIAS-3

Error Message     DEVICE-ALIAS-3-CFS_OPER_FAILED: [chars] 

Explanation    An error occurred while performing a CFS operation. [chars] indicates the CFS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the session. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-COMMIT_FAILED: [chars] 

Explanation    An error occurred while committing the database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-COMMIT_REJECTED: [chars] 

Explanation    Commit request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-LOCK_REJECTED: [chars] 

Explanation    Lock request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    An error occurred while activating the merged database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_ACTIVATION_REJECTED: [chars] 

Explanation    Merge activation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_FAILED: [chars] 

Explanation    An error occurred during merge operation. [chars] indicates the reason for failure.

Recommended Action    Compare device-alias configuration with the other switches in the fabric, resolve the conflicts if any and commit the changes.

Error Message     DEVICE-ALIAS-3-MERGE_MREQ_REJECTED: [chars] 

Explanation    MREQ received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_MRESP_REJECTED: [chars] 

Explanation    MRESP received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_VALIDATION_FAILED: [chars] 

Explanation    An error occurred while validating the merged database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MERGE_VALIDATION_REJECTED: [chars] 

Explanation    Merge validation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-MTS_OPER_FAILED: [chars] 

Explanation    An error occurred during MTS operation. [chars] indicates the MTS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-PSS_OPER_FAILED: [chars] 

Explanation    An error occurred during PSS operation. [chars] indicates the PSS operation and the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the lock. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-UNLOCK_REJECTED: [chars] 

Explanation    Unlock request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-VALIDATION_FAILED: [chars] 

Explanation    An error occurred while validating the database. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-3-VALIDATION_REJECTED: [chars] 

Explanation    Validation request received from remote switch is rejected. [chars] indicates the reason for failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DEVICE-ALIAS-6

Error Message     DEVICE-ALIAS-6-CLEAR_FAILED_INFO: [chars] 

Explanation    An error occurred while clearing the session. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-COMMIT_FAILED_INFO: [chars] 

Explanation    An error occurred while committing the database. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-IMPORT_DEFINITION_CONFLICT: Fcalias [chars] could not 
be imported due to definition conflict

Explanation    Fcalias [chars] could not be imported due to definition conflict. Either there is already a device-alias configuration present with the same definition OR another VSAN specified in the import VSAN range has an fcalias with the same definition.

Recommended Action    Resolve the conflict and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_MEMBER_TYPE_CONFLICT: Fcalias [chars] could not 
be imported due to having unsupported member type

Explanation    Fcalias [chars] could not be imported due to having unsupported member types. Fcalias can be imported only if it has Port WWN based members..

Recommended Action    Make sure that the fcalias has Port WWN based members and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_NAME_CONFLICT: Fcalias [chars] could not be 
imported due to name conflict 

Explanation    Fcalias [chars] could not be imported due to name conflict. Either there is already a device-alias configuration present with the same name OR another VSAN specified in the import VSAN range has an fcalias with the same name.

Recommended Action    Resolve the conflict and issue the import command again.

Error Message     DEVICE-ALIAS-6-IMPORT_NUM_MEMBERS_CONFLICT: Fcalias [chars] could not 
be imported due to having unsupported number of members

Explanation    Fcalias [chars] could not be imported due to having unsupported number of members. Fcalias can be imported only if it has exactly one member..

Recommended Action    Make sure that the fcalias has exactly one member and issue the import command again.

Error Message     DEVICE-ALIAS-6-LOCK_FAILED_INFO: [chars] 

Explanation    An error occurred while acquiring the lock. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-MERGE_ACTIVATION_FAILED_INFO: [chars] 

Explanation    An error occurred while activating the merged database. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-MERGE_VALIDATION_FAILED_BUSY: [chars] 

Explanation    Merged database could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.

Recommended Action    No DDTS.

Error Message     DEVICE-ALIAS-6-MERGE_VALIDATION_REJECTED_BUSY: [chars] 

Explanation    Merged database received from the remote switch could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.

Recommended Action    No DDTS.

Error Message     DEVICE-ALIAS-6-UNLOCK_FAILED_INFO: [chars] 

Explanation    An error occurred while releasing the lock. [chars] indicates the additional information regarding failure.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DEVICE-ALIAS-6-VALIDATION_ABORTED: [chars] 

Explanation    Local validation is aborted. [chars] indicates the reason why validation is aborted.

Recommended Action    No DDTS.

DEVICE_TEST Messages

This section contains the DEVICE_TEST messages.

DEVICE_TEST-2

Error Message    DEVICE_TEST-2-ASIC_REG_CHECK_FAIL: Module [dec] has failed test 
[chars] [dec] times on device [chars] [chars] [dec] frontpanel ports affected 
[chars] due to error [chars] 

Explanation    Online diagnostics ASICRegisterCheck test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-COMPACT_FLASH_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Compact Flash due to error [chars] 

Explanation    Online diagnostics CompactFlash test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-CRYPTO_DEVICE_FAIL: Module [dec] has failed test 
[chars] [dec] times on Crypto device due to error [chars] 

Explanation    Online diagnostics CryptoDevice test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-FAN_MOD_FAIL: Module [dec] has failed test [chars] 
[dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error 
[chars] error number [hex] 

Explanation    Online diagnostics SystemMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-MALLOC_FAILURE: Memory allocation failed 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-NVRAM_FAIL: Module [dec] has failed test [chars] [dec] 
times on device NVRAM due to error [chars] 

Explanation    Online diagnostics NVRAM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-POWER_SUPPLY_FAIL: Module [dec] has failed test [chars] 
[dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error 
[chars] error number [hex] 

Explanation    Online diagnostics SystemMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-PRIMARY_BOOTROM_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Primary BootROM due to error [chars] 

Explanation    Online diagnostics PrimaryBootROM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-PWR_MGMT_BUS_FAIL: Module [dec] has failed test [chars] 
[dec] times on device Power Mgmt Bus on slot [dec] due to error [chars] error 
number [hex] 

Explanation    Online diagnostics PwrMgmtBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-RTC_FAIL: Module [dec] has failed test [chars] [dec] 
times on device RealTimeClock due to error [chars] 

Explanation    Online diagnostics RealTimeClock test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-SECONDARY_BOOTROM_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Secondary BootROM due to error [chars] 

Explanation    Online diagnostics SecondaryBootROM test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-SPINE_CONTROL_BUS_FAIL: Module [dec] has failed test 
[chars] [dec] times on device Spine Control Bus on slot [dec] due to error [chars] 
error number [hex] 

Explanation    Online diagnostics SpineControlBus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-STANDBY_LOOPBACK_TEST_FAIL: Module [dec] has failed 
test [chars] [dec] times on [chars] [dec] due to error [chars] 

Explanation    Online diagnostics StandbyFabricLoopback test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-TWOWIRE_STW_FAIL: Module [dec] has failed test [chars] 
[dec] times on Status Bus on slot [dec] due to error [chars] 

Explanation    Online diagnostics Status bus test has failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-2-USB_FAIL: Module [dec] has failed test [chars] [dec] 
times on device USB due to error [chars] 

Explanation    Online diagnostics USB test has failed

Recommended Action    No action is required.

DEVICE_TEST-3

Error Message     DEVICE_TEST-3-STANDBY_TEST_GET_DIAG_VQI_FAIL: Standby test get diag 
vqi failed due to error [hex] 

Explanation    Device Test StandbyLoopback Test failed get vqi

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_GET_SPINE_FAIL: Standby test get spines 
failed due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test get spine failed

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_INIT_FAIL: Init for standby test failed 
due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test failed init process

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_MTS_FAIL: Mts Init for standby test failed 
due to error [hex] 

Explanation    Device Test StandbyFabricLoopback Test failed mts init

Recommended Action    No action is required.

Error Message     DEVICE_TEST-3-STANDBY_TEST_SOCKET_FAIL: Standby test socket error 
[chars]: [hex] 

Explanation    Device Test StandbyFabricLoopback Test Socket error

Recommended Action    No action is required.

DEVICE_TEST-4

Error Message     DEVICE_TEST-4-THREAD_CREATE_FAIL: Thread creation failed 

Explanation    Device Test process could not create threads

Recommended Action    No action is required.

Error Message     DEVICE_TEST-4-TIMER_CREATE_FAIL: Timer creation failed 

Explanation    Device Test process could not create timer

Recommended Action    No action is required.

Error Message     DEVICE_TEST-4-TIMER_START_FAIL: Timer start failed 

Explanation    Device Test process could not start timer

Recommended Action    No action is required.

DEVICE_TEST-5

Error Message     DEVICE_TEST-5-NOTICE_TEST: Memory allocation failed notice 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

DEVICE_TEST-6

Error Message     DEVICE_TEST-6-INFO_TEST: Memory allocation failed info 

Explanation    Device Test process could not allocate memory

Recommended Action    No action is required.

DEV_LOG Messages

This section contains the DEV_LOG messages.

DEV_LOG-3

Error Message    DEV_LOG-3-ERROR: [chars] 

Explanation    Dev_log_lc encountered an error

Recommended Action    No action is required.

DEV_LOG-SLOT#-4

Error Message     DEV_LOG-SLOT#-4-DEV_LOG_LC_ERROR: [chars] 

Explanation    Dev_log_lc encountered an error

Recommended Action    No action is required.

DFTM Messages

This section contains the DFTM messages.

DFTM-3

Error Message    DFTM-3-DFTM_BDDB_PROG_FAILED: DFTM failed to program BDDB Entry: 
[chars] 

Explanation    DFTM failed to program BDDB Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_BDT_PROG_FAILED: DFTM failed to program BD Table Entry: 
[chars] 

Explanation    DFTM failed to program BD Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_L2L3CT_PROG_FAILED: DFTM failed to program L2L3 
Consistency Table Entry: [chars] 

Explanation    DFTM failed to program L2L3 Consistency Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_MFT_PROG_FAILED: DFTM failed to program Multicast FTag 
Table Entry: [chars] 

Explanation    DFTM failed to program Multicast Ftag Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_SDT_PROG_FAILED: DFTM failed to program SGT DGT Table 
Entry: [chars] 

Explanation    DFTM failed to program SGT DGT Table Entry

Recommended Action    No action is required.

Error Message     DFTM-3-DFTM_VTT_PROG_FAILED: DFTM failed to program VLAN Translation 
Table Entry: [chars] 

Explanation    DFTM failed to program VLAN Translation Table

Recommended Action    No action is required.

DHCP_SNOOP Messages

This section contains the DHCP_SNOOP messages.

DHCP_SNOOP-2

Error Message    DHCP_SNOOP-2-DHCP_SNOOP_PROGRAM_EXIT: [chars] 

Explanation    DHCP snoop process did an abnormal exit

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-INITFAIL: DHCP Daemon Initialization failed: [chars] 

Explanation    DHCP Daemon Initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-PSSERROR: [chars] 

Explanation    DHCP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-2-REGPARTREE: Unable to register par tree: [chars] 

Explanation    Could not register par tree. [chars] explains the reason for the failure.

Recommended Action    No action is required.

DHCP_SNOOP-3

Error Message     DHCP_SNOOP-3-ALLOCFAIL: Heap Memory allocation failed: [chars] 

Explanation    DHCP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-DHCPDENIEDARP: ARP frame denied due to DHCP snooping 
binding on interface [chars] vlan [dec] sender mac [chars] sender ip [chars] target 
mac [chars] target ip [chars].

Explanation    [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been denied. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-DHCPRATELIMIT: Interface [chars] has been error disabled 
due to excessive ingress rate [dec] of DHCP packets.

Explanation    [chars] identifies the interface which has been error disabled due to excessive ingress rate [dec].

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-HWPGMFAILURE: Hardware programming has failed: [chars] 

Explanation    Hardware programming has failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-INVDHCPPKTS: Validation errors while processing DHCP 
packet received on interface [chars] vlan [dec] Reason:[chars]. Dropping the 
packet

Explanation    Validation errors DHCP packet receieved on the interface [chars] vlan [[dec]]. Reason:[chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-MTSERROR: [chars] 

Explanation    DHCP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-PKTRECVFAIL: Failed to receive packet - [chars] 

Explanation    Failed to receive packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-PKTSENDFAIL: Failed to send packet, - [chars] 

Explanation    Failed to send packet. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-SOCKBINDFAIL: Failed to bind to raw socket - [chars] 

Explanation    Failed to bind to socket. [char] identifies the reason.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-3-SOCKOPENFAIL: Failed to open socket for receiving DHCP 
packets - [chars] 

Explanation    An attempt to open a socket for receiving DHCP packets failed. [char] identifies the reason.

Recommended Action    No action is required.

DHCP_SNOOP-4

Error Message     DHCP_SNOOP-4-ACL_DENY: [dec] Invalid ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-ACL_PERMIT: [dec] ARP messages ([chars]) on [chars], 
vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]]) 

Explanation    Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-DHCP_SNOOPING_DENY: [dec] Invalid ARP messages ([chars]) 
on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-DHCP_SNOOPING_PERMIT: [dec] ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]]) 

Explanation    Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-ERROR_DISABLED: Interface [chars] has moved to error 
disabled state due to excessive rate [dec] of ingress ARP packets

Explanation    Interface [chars] has moved to error disabled state due to excessive rate [dec] of ingress ARP packets

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-4-INVALID_ARP: [dec] Invalid ARP messages ([chars]) on 
[chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])

Explanation    Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])

Recommended Action    No action is required.

DHCP_SNOOP-6

Error Message     DHCP_SNOOP-6-DAIVLANDISABLE: DAI disabled on vlan [dec] 

Explanation    Dynamic ARP Inspection was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DAIVLANENABLE: DAI enabled on vlan [dec] 

Explanation    Dynamic ARP Inspection was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPEXIT: DHCP Daemon shutting down gracefully. 

Explanation    DHCP Daemon is shutting down gracefully. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPHOSTADD: A new Host is [chars] connected to interface 
[chars] in VLAN [dec] and is allocated IP address [chars] for [dec] secs.

Explanation    A Host identified by [chars] has been added. [chars] identifies the interface. [dec] identifies the VLAN. [chars] identifies IP address. [dec] identifies the lease time in secs. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPLEASEEXPIRE: Lease expired for host [chars] having 
IP address [chars] connected to interface [chars] in VLAN [dec] for lease [dec] 
secs.

Explanation    The lease for host identified by [chars] with IP address [chars] connected to interface [chars] in VLAN [dec] with lease [dec] has expired.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPPERMITTEDARP: ARP frame permitted due to DHCP 
snooping binding on interface [chars] vlan [dec] sender mac [chars] sender ip 
[chars] target mac [chars] target ip [chars].

Explanation    [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been permitted. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPPKTFWD: Gracefully forwarding DHCP packet. 
reason:[chars] 

Explanation    Gracefully forwarding DHCP packet. reason [chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-DHCPUP: DHCP Daemon Up. 

Explanation    DHCP Daemon was created successfully and is up and running. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INFO: [chars] 

Explanation    An event during switchover. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INTFDISABLE: IP Src Guard disabled on intf [chars] 

Explanation    IP Src Guard was disabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-INTFENABLE: IP Src Guard enabled on intf [chars] 

Explanation    IP Src Guard was enabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-NONDHCPPKTFWD: Non DHCP packet with src port:[dec] dst 
port:[dec] on intf:[chars] vlan:[dec]. Forwarding on [chars]

Explanation    Non DHCP packet arrived with UDP src/dst ports [dec], [dec] on interface [chars], vlan [dec]. Forwarding the packet on [chars]

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-VLANDISABLE: DHCP Snooping disabled on vlan [dec] 

Explanation    DHCP Snooping was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

Error Message     DHCP_SNOOP-6-VLANENABLE: DHCP Snooping enabled on vlan [dec] 

Explanation    DHCP Snooping was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.

Recommended Action    No action is required.

DIAGCLIENT Messages

This section contains the DIAGCLIENT messages.

DIAGCLIENT-2

Error Message    DIAGCLIENT-2-DIAG_BOOTUP_COMPLETE: Module <[dec]> Bootup Test 
<[chars]> has reported <[chars]>

Explanation    Bootup Test completed

Recommended Action    Nothing to be done if the test reports SUCCESS otherwise copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information

Error Message     DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <[chars]> has been disabled 
as a part of default EEM action 

Explanation    Informational Syslog

Recommended Action    No action is required.

Error Message     DIAGCLIENT-2-PSS_READ_FAILURE: Read from PSS failed on Module <[dec]>

Explanation    Read operation from PSS store failed

Recommended Action    No action is required.

Error Message     DIAGCLIENT-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]>

Explanation    Write operation on PSS store failed

Recommended Action    No action is required.

DIAGCLIENT-3

Error Message     DIAGCLIENT-3-DIAG_HM_FAIL: Module <[dec]> Health Monitoring Test 
<[chars]> has failed. Please use 'show diagnostic result <target>' to see test 
results

Explanation    A Health Monitoring Test has reported failure

Recommended Action    Ensure the line card is firmly in the slot, reseat if necessary, and attempt to run the test again if the line card is not seated properly in the slot. If the line card was properly seated in the slot, copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information.

Error Message     DIAGCLIENT-3-ONDEMAND_FAIL_EXCESS: Module <[dec]> Test <[chars]> has 
failed more than <[dec]> number of times 

Explanation    Ondemand test has failed more than configured number of times

Recommended Action    Copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information

Error Message     DIAGCLIENT-3-PER_PORT_TEST_FAIL: Module <[dec]> Test <[chars]> has 
failed on Ports <[chars]> Please use 'show diagnostic result <target>' to see test 
results

Explanation    Per Port Test has failed on the above all ports

Recommended Action    No action is required.

DIAGCLIENT-4

Error Message     DIAGCLIENT-4-LC_OFFLINE_FOR_CURR_SLOT: Received LC offline event for 
the current slot:[dec]. Ignoring it 

Explanation    Informational Syslog

Recommended Action    No action is required.

Error Message     DIAGCLIENT-4-MTS_SEND_FAILURE: MTS send failed, mts_opc: [chars], 
dest slot: [dec], dest SAP: [dec], error-id: [hex] 

Explanation    MTS send reports failure

Recommended Action    No action is required.

DIAGCLIENT-5

Error Message     DIAGCLIENT-5-CALLOC_FAILURE: Memory allocation failed 

Explanation    DiagClient process could not allocate memory

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-DIAG_SCHED_COMPLETE: Module <[dec]> Test <[chars]> has 
completed Scheduled Testing 

Explanation    A scheduled Test was completed

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-ONDEMAND_FAIL: Module <[dec]> Test <[chars]> has failed 
in Test_Iteration <[dec]> 

Explanation    The specified test has reported FAILURE in this Iteration

Recommended Action    No action is required.

Error Message     DIAGCLIENT-5-ONDEMAND_SUCCESS: Module <[dec]> Test <[chars]> has 
completed successfully in Test_Iteration <[dec]> 

Explanation    The specified test has reported SUCCESS in this Iteration

Recommended Action    No action is required.

DIAGMGR Messages

This section contains the DIAGMGR messages.

DIAGMGR-2

Error Message    DIAGMGR-2-MTS_SEND_FAILURE: MTS send failed, mts_opc: [chars], dest 
slot: [dec], dest SAP: [dec], error-id: [hex] 

Explanation    MTS send reports failure

Recommended Action    No action is required.

Error Message     DIAGMGR-2-PSS_DELETE_FAILURE: Read from PSS failed on Module <[dec]> 

Explanation    Read operation from PSS store failed

Recommended Action    No action is required.

Error Message     DIAGMGR-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]> 

Explanation    Write operation on PSS store failed

Recommended Action    No action is required.

DIAGMGR-3

Error Message     DIAGMGR-3-DIAG_MAJOR_DEFECT: Module <[dec]> Test <[chars]> detected 
a Major Error Please use 'show diagnostic result <target>' to see test results

Explanation    A major error was detected during diagnostic testing

Recommended Action    Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.

Error Message     DIAGMGR-3-DIAG_MINOR_DEFECT: Module <[dec]> Test <[chars]> detected 
a Minor Error Please use 'show diagnostic result <target>' to see test results

Explanation    A minor error was detected during diagnostic testing

Recommended Action    Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information

Error Message     DIAGMGR-3-GET_CURR_SLOT_FAIL: Failed to get the current slot for the 
process. Error:[chars] 

Explanation    The process initialization failed to get the current slot.

Recommended Action    This is an informational message stating that a process initialization failure.

DIAGMGR-4

Error Message     DIAGMGR-4-CURR_SLOT_OFFLINE: Recevied an LC offline event for the 
current slot:[dec]. Ignoring it 

Explanation    The process received an offline event for the slot it is running. Ignoring it.

Recommended Action    This is an informational message stating that an unexpected event has been encountered.

Error Message     DIAGMGR-4-DISRPT_TST_START: Starting Test <[chars]> on Module <[dec]> 
is Disruptive 

Explanation    Starting a Disruptive Test can disturb the system's normal functionality

Recommended Action    Reset target module

Error Message     DIAGMGR-4-FIXED_INTRVL_CHANGED: The users are not allowed to change 
monitoring interval of Test <[chars]>

Explanation    The specified health monitoring test interval is not user-configurable and therefore cannot be changed

Recommended Action    Nothing. The specific health monitoring interval is not user- configurable by design so nothing can be done to change the interval.

DIAGMGR-5

Error Message     DIAGMGR-5-BOOTUP_CONF: Diagnostic Bootup Level: <[chars]>

Explanation    Current Diagnostic BootUp Level being configure or changed

Recommended Action    No action is required.

Error Message     DIAGMGR-5-CALLOC_FAILURE: Memory allocation failure 

Explanation    Memory allocation in a call to malloc/calloc has failed

Recommended Action    No action is required.

Error Message     DIAGMGR-5-CHANGE_ALWAYS_HM: Health Monitoring test <[chars]> in 
Module <[dec]> is a must run and cannot be modified

Explanation    The specified health monitoring test must be run and cannot be disabled

Recommended Action    Nothing. The specific health monitoring test cannot be disabled by design. The system is working properly.

Error Message     DIAGMGR-5-HM_START: Health monitoring test <[chars]> for Module 
<[dec]> 

Explanation    Health Monitoring Test started

Recommended Action    No action is required.

Error Message     DIAGMGR-5-HM_STOP: Disabling health monitoring test <[chars]> for 
Module <[dec]> 

Explanation    Health Monitoring Test has been stopped It can be enabled through the diagnostic monitor..... command

Recommended Action    No action is required.

Error Message     DIAGMGR-5-INTRVL_INCORRECT: Monitoring Interval is less than minimum 
of [dec] seconds required for Module <[dec]> test <[chars]>

Explanation    Health Monitoring cannot be enabled for the specified test because the interval for the test has been incorrectly set

Recommended Action    The system is working properly and no action is required. If you want to specify a smaller testing interval, the error message text provides the lowest possible configurable interval for the specified monitoring interval

Error Message     DIAGMGR-5-MODULE_MISSING: Diagnostic command issued on non-existing 
Module <[dec]> 

Explanation    A line card could not be located in a slot where a diagnostic action was requested

Recommended Action    Ensure the targeted line card is properly seated in the specified slot. If the line card is properly seated, ensure the correct slot was indicated in the command-line interface. If the line card is well-seated and the correct slot was specified, copy the error message exactly as it appears on the screen as well as the output of show tech-support and paste the output into a separate file. Contact your technical support representative with the gathered information

Error Message     DIAGMGR-5-NONHM_AS_HM: The Test <[chars]> cannot be used as health 
monitoring test 

Explanation    Non-HM test cannot be scheduled to run as a Health Monitoring test

Recommended Action    No action is required.

DIAGMGR-6

Error Message     DIAGMGR-6-BOOTUP_DIAG_OK: Module <[dec]>: Passed Online Diagnostics

Explanation    The diagnostic tests did not detect any error on the card.

Recommended Action    This is an informational message stating that the line card passed the diagnostic tests.

Error Message     DIAGMGR-6-BOOTUP_TEST_STARTED: Module <[dec]>: Running [chars] 
Diagnostics

Explanation    Starting bootup testing for above module

Recommended Action    No action is required.

DIAG_PORT_LB Messages

This section contains the DIAG_PORT_LB messages.

DIAG_PORT_LB-2

Error Message    DIAG_PORT_LB-2-LCM_RESP_SEND_FAILURE: LC Inserted request response 
send to Module Manager failed . Error:[chars]

Explanation    Failed to send the response for LC insertion to Module Manager.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-LIF_GET_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed to get Diagnostic LIF id

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-MALLOC_FAILURE: [chars]([dec]) Memory allocation 
failed. 

Explanation    Port Loopback test process could not allocate memory

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-PORTLOOPBACK_TEST_FAIL: Module:[dec] 
Test:PortLoopback failed [dec] consecutive times. Faulty module:[chars] affected 
ports:[chars] Error:[chars]

Explanation    PortLoopback test failed on the module consecutively

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-PROC_INIT_FAILURE: [chars]([dec]) [chars] 
Error:[chars] 

Explanation    Port Loopback test process failed in process initialization

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-2-REWRITE_ENGINE_LOOPBACK_TEST_FAIL: Module:[dec] 
Test:RewriteEngine Loopback failed [dec] consecutive times. Faulty module:[chars] 
affected ports:[chars] Error:[chars]

Explanation    Rewrite Engine Loopback test failed on the module consecutively

Recommended Action    No action is required.

DIAG_PORT_LB-3

Error Message     DIAG_PORT_LB-3-DIAG_FWD_PATH_SETUP_FAILURE: [chars]. Module:[dec] 
Error:[chars]. 

Explanation    Forwarding path setup for port loopback tests failed

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-DIAG_PKT_SEND_FAILURE: [chars]([dec]) [chars]. 
Error:[chars] 

Explanation    Port Loopback test process failed to send loopback packets.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-FSM_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars] 

Explanation    Port Loopback test process failed in MTS API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-GET_DIAG_BD_FAIL: [chars]([dec]) Failed to get the BD 
for Diag VLAN:[dec]. Error:[chars]. 

Explanation    Failed to get the BD corresponding to the Diag VLAN

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-IFINDEX_LIB_FAILURE: [chars]([dec]) [chars] 
[chars]:[hex] [chars] [chars] 

Explanation    Port Loopback test process failed in if_index library API

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-INVALID_TEST_REQUEST: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to get test request info.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-INVALID_TEST_RUN: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to get the current test run information

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-MTS_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars] 

Explanation    Port Loopback test process failed in MTS API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PDB_LIB_API_ERROR: Failed to [chars]. Error:[dec]. 

Explanation    The port loopback test was not able to get chassis info

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PIXM_LIB_ERROR: [chars]([dec]) Failed to convert 
[chars]:[hex] to [chars]. Error:[chars] 

Explanation    Port Loopback test process failed to convert port ifindex <-> port index.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PORT_CFG_REQ_SEND: [chars]([dec]) Failed to send 
request to configure port ifindex:[dec] for port loopback test

Explanation    Failed to configure/restore the port to do/cleanup port loopback testing

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-PORT_CLIENT_LIB_ERROR: [chars]([dec]) [chars]. 
Error:[chars] 

Explanation    Port Loopback test process failed in Port Client API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RESULT_ADD_FAILURE: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed to add the port test result

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RESULT_SEND_FAILURE: [chars]([dec]) [chars] 

Explanation    Port Loopback test process failed to send the test results

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-RW_ENGINE_LOOPBACK_TEST_SPINE_PATH_FAIL: Module:[dec] 
Test:RewriteEngine Loopback Spine path:[dec] failed [dec] consecutive times. 
Error:[chars]

Explanation    Rewrite Engine Loopback test failed on the spine path consecutively

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-SOCKET_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed in socket operations

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-STATS_LIB_ERROR: [chars]([dec]) [chars]:[dec] 

Explanation    Port Loopback test process failed in stats infra lib API.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-TEST_RES_SEND_FAIL: Failed to send [chars] test 
results back to Diagnostics Infrastucture. Error:[chars].

Explanation    The port loopback test was not able to send the test results

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-TIMER_LIB_ERROR: [chars]([dec]) [chars] 

Explanation    Port Loopback test process timer handling failure.

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-VLAN_ERROR: [chars]([dec]) [chars] Error:[chars] 

Explanation    Port Loopback test process failed to get Diagnostic VLAN info

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-VQI_GET_FAIL: Failed to get the Diag VQi from XBM. 
Error:[chars] 

Explanation    Rewrite Engine Loopback test failed to get the Diag VQi from XBAR Mgr

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-3-XBM_CFG_REQ_FAIL: Failed to conigure the XBAR mask 
while running the RewriteEngineLoopback test. Error:[chars]. Module:[dec] could 
have gone offline

Explanation    Rewrite Engine Loopback test failed to set the XBAR mask while running the test. The target module could have gone offline

Recommended Action    No action is required.

DIAG_PORT_LB-5

Error Message     DIAG_PORT_LB-5-DIAG_PORT_LB_DISABLED: DIAG_PORT_LB Disabled 

Explanation    DIAG_PORT_LB Service Disabled

Recommended Action    No action is required.

Error Message     DIAG_PORT_LB-5-DIAG_PORT_LB_ENABLED: DIAG_PORT_LB Enabled 

Explanation    DIAG_PORT_LB Service nabled

Recommended Action    No action is required.

DMM Messages

This section contains the DMM messages.

DMM-SLOT#-5

Error Message    DMM-SLOT#-5-LOG_ERR_DMM_NEW_NPORT_SRVR_ZONE: Job Id:%Ld VSAN :[dec] 
New N-Port FCID :[hex] Server FCID:[hex] are in the same zone. ALERT!!

Explanation    A New N-Port has come up which is zoned in the same zone as the Server

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_NEW_NPORT_STG_ZONE: Job Id:%Ld VSAN :[dec] 
New N-Port FCID :[hex] Storage FCID:[hex] are in the same zone. ALERT!!

Explanation    A New N-Port has come up which is zoned in the same zone as the Storage

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_SRVR_RSCN: Job Id:%Ld Server N-Port 
pWWN:0x%Lx [chars] 

Explanation    An RSCN event was received for the Server associated with a Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_ERR_DMM_STG_RSCN: Job Id:%Ld N-Port pWWN:0x%Lx 
Storage:[chars] [chars]

Explanation    An RSCN event was received for the Storage associated with a Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_COMPLETE: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the completion of a Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR_LOST_SSM_PEER_CONNECTION: Job 
Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job due to loss in ip connectivity to peer ssm

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_FINISH: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating Finish-request for a Method-2 Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_START: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the start of a Data Migration Job

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_STOP: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating that the Data Migration Job was stopped by Administrator

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_TCP_CONNECTION_DOWN: Job Id:%Ld lost 
connection to peer [chars]. Job may be RESET 

Explanation    Event indicating IP Connectivity loss to peer SSM. Affected Job maybe be RESET

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_COMPLETE: Job Id:%Ld 
NumSession:[dec] 

Explanation    Event indicating the completion of a Data Migration Job Verification

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_ERROR: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job Verification due to an error

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_START: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the start of a Data Migration Job Verification

Recommended Action    No action is required.

Error Message     DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_STOP: Job Id:%Ld NumSession:[dec] 

Explanation    Event indicating the Suspension of Data Migration Job Verification by the user

Recommended Action    No action is required.

DOT1X Messages

This section contains the DOT1X messages.

DOT1X-2

Error Message    DOT1X-2-DOT1X_INIT: Dot1x unable to start 

Explanation    The system failed to create the Dot1x process

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DOT1X-3

Error Message     DOT1X-3-ERR_SPANDST: It is configured as a SPAN Dest port. 

Explanation    Dot1x and SPAN Dest ports are mutually exclusive features.

Recommended Action    Disable SPAN destination port configuration first before reconfiguring Dot1x on the port.

Error Message     DOT1X-3-INVALID_INPUT: Invalid on interface [chars]. 

Explanation    The Dot1x interface parameter is out of the specified range or is invalid.

Recommended Action    Refer to the CLI help documentation to determine the valid 802.1x parameters.

Error Message     DOT1X-3-MEM_UNAVAIL: perform the 802.1X action. 

Explanation    Insufficient system memory is available to perform the Dot1x Authentication.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     DOT1X-3-NOT_DOT1X_CAPABLE: interface [chars] because it is not a 
physical Ethernet interface. 

Explanation    Dot1x Authentication can only be enabled on physical Ethernet interfaces.

Recommended Action    Enable Dot1x Authentication on physical Ethernet interfaces only.

Error Message     DOT1X-3-SM_INIT: Internal error while initializing state machine 
[chars], state [chars]: [chars] 

Explanation    An attempt was made to initialize an invalid state machine.

Recommended Action    Initialize dot1x state machine.

DOT1X-4

Error Message     DOT1X-4-BADEVENT: Event [chars] is invalid for the current state 
[chars]: [chars] [chars] 

Explanation    An attempt was made to post an event to a state machine that is invalid for the current state.

Recommended Action    Initialize dot1x state machine

Error Message     DOT1X-4-MAB_DISABLED_ON_PCM: Interface [chars] is a member of 
portchannel, MAB is not supported on this port 

Explanation    MAB is not supported on portchannel member port

Recommended Action    To enable MAB make sure that port is not member of portchannel

Error Message     DOT1X-4-MAB_DISABLED: Interface [chars] is in Trunk mode, MAB is not 
supported on this port 

Explanation    MAB is not supported on Trunk port

Recommended Action    To enable MAB make sure that port is not in trunk mode

Error Message     DOT1X-4-MULTIHOST_ON_PCM: Interface [chars] is a member of 
portchannel, dot1x host mode will be multi-host and changing it to single-host 
mode won't be supported

Explanation    Current Port is a member of portchannel, so dot1x host mode has to be in multi-host mode.

Recommended Action    To change host mode, ensure that port is not a member of portchannel

Error Message     DOT1X-4-STOPPED: Event [chars] ignored because the state machine is 
stopped: [chars] [chars] 

Explanation    An attempted was made to post an event to a state machine that has already been stopped.

Recommended Action    An internal error has occurred with the state machine. The traceback should indicate the guilty party.

Error Message     DOT1X-4-TO_MULTIHOST: Interface [chars] is in trunk mode, dot1x host 
mode will be multi-host and changing it to single-host mode won't be supported

Explanation    Current Port is in trunk mode, so dot1x host mode has to be in multi-host mode.

Recommended Action    To change host mode, ensure that port is not in trunk mode.

DOT1X-5

Error Message     DOT1X-5-DOT1X_DISABLED: dot1x Disabled 

Explanation    Dot1x Service Disabled

Recommended Action    No action is required.

Error Message     DOT1X-5-DOT1X_ENABLED: dot1x Enabled 

Explanation    Dot1x Service Enabled

Recommended Action    No action is required.

Error Message     DOT1X-5-INVALID_MAC: broadcast or multicast mac address) [chars] is 
trying to authenticate. 

Explanation    Authentication using 802.1x is not allowed for zero, broadcast, and multicast source MAC addresses.

Recommended Action    Connect a Dot1x supported Host to the Dot1x enabled port.

Error Message     DOT1X-5-SECURITY_VIOLATION: New MAC address [chars] is seen on 
interface [chars] in [chars] mode 

Explanation    The port on the interface specified in the error message is configured in single host mode. Any new host that is detected on the interface is treated as a security violation. The port has been Error disabled.

Recommended Action    Ensure that the port is configured to use only one host. Enter the <Cmd>shutdown<Cmd> followed by <CmdBold>no shutdown<CmdBold> command to restart the port.

Error Message     DOT1X-5-SESSION_CREATION: Dot1x authentication session initiated in 
interface [chars] using authentication method [chars]

Explanation    Dot1x authentication session has been created after successful authentication of supplicant

Recommended Action    No action is required.

Error Message     DOT1X-5-SESSION_TERMINATION: Dot1x authentication session in 
interface [chars] using authentication method [chars] is terminated because of 
[chars] and port moved to [chars] state

Explanation    Dot1x authentication session has been terminated

Recommended Action    No action is required.

Error Message     DOT1X-5-STATUS: Dot1x interface [chars] status changed from [chars] 
to [chars] 

Explanation    Dot1x authenticator has changed its internal state

Recommended Action    No action is required.

DPP_DEBUG Messages

This section contains the DPP_DEBUG messages.

DPP_DEBUG-2

Error Message    DPP_DEBUG-2-DPP_CRIT: [DPP[dec]] [chars] 

Explanation    A DPP generated a critical message

Recommended Action    No action is required.

DPVM Messages

This section contains the DPVM messages.

DPVM-2

Error Message    DPVM-2-ALLOC_FAILED: Memory allocation failed for size:[dec] for 
[chars] 

Explanation    Memory allocation failed for size [dec] for [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-2-DPVM_DUPL_REJECT: [chars] 

Explanation    Rejected duplicate pwwn query

Recommended Action    Dpvm overwrite-duplicate-pwwn

DPVM-3

Error Message     DPVM-3-DB_ERR: [chars] 

Explanation    An error occured during an DPVM database operation. [chars] indicates the reason for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message    DPVM-3-DDAS_MODE_INVALID: [chars] 

Explanation    DDAS mode Invalid. [chars]

Recommended Action    Flip DDAS mode

Error Message     DPVM-3-INIT_FAIL: [chars] 

Explanation    An error happened during DPVM Initialization. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-3-MTS_ERR: [chars] 

Explanation    An error occured in processing of an MTS message. [chars] indicates the error that occured

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     DPVM-3-PSS_ERR: [chars] 

Explanation    An error occured during an DPVM PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

DPVM-4

Error Message     DPVM-4-ACTIVATION_FAIL: [chars] 

Explanation    Activation of DPVM device mappings failed due to [chars]

Recommended Action    Correct the error and reactivate database again

Error Message     DPVM-4-FEATURE_DISABLED: [chars] 

Explanation    DPVM is unavailable and disabled now

Recommended Action    No action is required.

DPVM-6

Error Message     DPVM-6-FEATURE_ENABLED: [chars] 

Explanation    DPVM is available and enabled now

Recommended Action    No action is required.

Error Message     DPVM-6-INFO: [chars] 

Explanation    An event happened that affects DPVM. [chars] indicates the event

Recommended Action    No action is required.

DSTATS Messages

This section contains the DSTATS messages.

DSTATS-2

Error Message    DSTATS-2-PSS_INIT_FAIL: pss initialization failed due to error: [hex] 

Explanation    Dstats process pss initialization failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

DSTATS-3

Error Message    DSTATS-3-PSS_CREATE_FAIL: pss create runtime database failed due to 
error: [hex] 

Explanation    Dstats process pss create runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed 
due to error: [hex] 

Explanation    Dstats process pss delete runtime entry key [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to 
error: [hex] 

Explanation    Dstats process pss set runtime max key failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed due to 
error: [hex] 

Explanation    Dstats process pss set runtime max value failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_OPEN_FAIL: pss open runtime database failed due to error: 
[hex] 

Explanation    Dstats process pss open runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_RELOAD_FAIL: pss reload runtime database failed due to 
error: [hex] 

Explanation    Dstats process pss reload runtime database failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_SNAPSHOT_DEBUG_FAIL: pss snapshot runtime debug to 
uri:[chars] failed due to error: [hex] 

Explanation    Dstats process pss snapshot of runtime debug to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_SNAPSHOT_FAIL: pss snapshot runtime to uri:[chars] 
failed due to error: [hex] 

Explanation    Dstats process pss snapshot of runtime to uri [string] failed due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

Error Message     DSTATS-3-PSS_STORE_FAIL: pss store runtime entry key:[hex] val:[hex] 
failed due to error: [hex] 

Explanation    Dstats process pss store runtime entry key [hex] value [hex] failure due to error [hex].

Recommended Action    Collect more information using command 'show flash'. See pss system error codes for reason.

ELTMC Messages

This section contains the ELTMC messages.

ELTMC-SLOT#-2

Error Message    ELTMC-SLOT#-2-ELTMC_INTERFACE_INTERNAL_ERROR: Internal error: 
[chars]:[chars], collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTERNAL_ERROR: Internal error: [chars], collect 
output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_NOT_FOUND: Interface [chars] not found in 
ELTM database [chars] 

Explanation    ELTM database doesn't have the interface.

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_NOT_SUPP: Interface [chars] not supported by 
ELTM [chars] 

Explanation    ELTM doesn't support the interface for the specified operation

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_TO_LTL: Failed to get LTL for interface 
[chars] return status [chars] 

Explanation    ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_INTF_TO_SLOT: Failed to get slot for interface 
[chars] return status [chars] 

Explanation    ELTM Failed to get Slot for interface. Port-channels and L2 Learning might be effected

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_INTF: Failed to allocate L2 LIF 
entries in forwarding engine for interfac [chars] 

Explanation    ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding for the interface

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_VDC: Failed to allocate L2 LIF 
entries in forwarding engine 

Explanation    ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding in this VDC

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_L3_INGRESS_LIF_ALLOC_FAIL_INTF: Failed to 
allocate L3 Ingress LIF entries in forwarding engine for interfac [chars] 

Explanation    ELTM Failed to allocate L3 Ingress LIF entries in forwarding engine. This will effect Layer 3 forwarding for the interface

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_RSVD_VLAN: Failed to get the reserved vlans. 
Failed with error [chars] 

Explanation    ELTM Failed to get the reserved vlan's. This will effect multicast forwarding on SVI interfaces

Recommended Action    No action is required.

Error Message     ELTMC-SLOT#-2-ELTMC_VLAN_INTERNAL_ERROR: Internal error: VLAN 
[dec]:[chars], collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

ELTM Messages

This section contains the ELTM messages.

ELTM-2

Error Message    ELTM-2-INTERFACE_INTERNAL_ERROR: Internal error: [chars]:[chars], 
collect output of show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTM-2-INTERNAL_ERROR: Internal error: [chars], collect output of 
show tech-support eltm 

Explanation    ELTM hit a internal error. Collect show tech-support eltm for futher analysis.

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_NOT_FOUND: Interface [chars] not found in ELTM database 
[chars] 

Explanation    ELTM database doesn't have the interface.

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_NOT_SUPP: Interface [chars] not supported by ELTM [chars] 

Explanation    ELTM doesn't support the interface for the specified operation

Recommended Action    No action is required.

Error Message     ELTM-2-INTF_TO_LTL: Failed to get LTL for interface [chars] return 
status [chars] 

Explanation    ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine

Recommended Action    No action is required.

ELTM-6

Error Message     ELTM-6-ELTM_MTS_SEND_FAILED: Failed to send MTS message errno [hex] 
opcode [dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

EOU Messages

This section contains the EOU messages.

EOU-2

Error Message    EOU-2-PBACL_APPLICATION_FAILURE: [chars] of host [chars] to/from pbacl 
group [chars] failed. Error : [chars] 

Explanation    Failure of host addition/deletion to/from pbacl group

Recommended Action    Please verify the addition/deletion of the host using the cli show object-group. If it was a delete request that failed, manual deletion of the host from the group is recommended

EOU-5

Error Message     EOU-5-L2NAC_DISABLED: EOU Disabled 

Explanation    Service EOU Disabled

Recommended Action    No action is required.

Error Message     EOU-5-L2NAC_ENABLED: EOU Enabled 

Explanation    Service EOU enabled

Recommended Action    No action is required.

EOU-6

Error Message     EOU-6-AAA_DOWN: Default Policy ip: [chars]:retained 

Explanation    Policy retained

Recommended Action    No action is required.

Error Message     EOU-6-AUTHTYPE: Authtype: ip: [chars] Authtype:[chars] 

Explanation    Authentication type

Recommended Action    No action is required.

Error Message     EOU-6-BAD_PKT: Bad Packet: ip: [chars] Why: [chars] 

Explanation    Bad Packet because of reason specified

Recommended Action    No action is required.

Error Message     EOU-6-CTA: CTA: ip: [chars] status(detected/not detected): [chars] 

Explanation    CTA detected or not

Recommended Action    No action is required.

Error Message     EOU-6-IDENTITY_MATCH: Identity Match: ip: [chars] Policy: [chars] 

Explanation    Identity Matched or not

Recommended Action    No action is required.

Error Message     EOU-6-PBACL_APPLICATION_STATUS: [chars] of host [chars] to/from pbacl 
group [chars] succeeded 

Explanation    Status of host addition/deletion to pbacl group

Recommended Action    No action is required.

Error Message     EOU-6-POLICY: Policy on ip: [chars]: [chars]: [chars] 

Explanation    Policy applied

Recommended Action    No action is required.

Error Message     EOU-6-POSTURE: Posture:ip: [chars] Status: [chars], Interface: 
[chars] 

Explanation    Posture of host

Recommended Action    No action is required.

Error Message     EOU-6-SESSION: Session ip: [chars] Action:[chars] , Interface: 
[chars] 

Explanation    Session detected

Recommended Action    No action is required.

Error Message     EOU-6-SOCKET: Service eou on port: [dec] 

Explanation    Eou using above port

Recommended Action    No action is required.

Error Message     EOU-6-SQ_EAP_MSG: Status Query: ip: [chars] status: [chars] 

Explanation    Status query state

Recommended Action    No action is required.

Error Message     EOU-6-UNKN_EVENT_ERR: Unknow Event Err: ip: [chars] Message: [chars] 

Explanation    Error due to unknown event

Recommended Action    No action is required.

Error Message     EOU-6-VERSION_MISMATCH: Eou version mismatch ip: [chars] and version 
[dec] 

Explanation    Eou version mismatch

Recommended Action    No action is required.

EOU-7

Error Message     EOU-7-EOU_DISABLED_INTF: eou disabled on interface [chars] 

Explanation    Eou service disabled on interface

Recommended Action    No action is required.

Error Message     EOU-7-EOU_ENABLED_INTF: eou enabled on interface [chars] 

Explanation    Eou service enabled on interface

Recommended Action    No action is required.

EPP Messages

This section contains the EPP messages.

EPP-5

Error Message    EPP-5-EPP_FAILURE: Interface [chars] EPP Failure 

Explanation    Trunk protocol failed

Recommended Action    'show epp internal event-history err' will indicate the errors encountered

Error Message     EPP-5-EPP_LOOPBACK: Interface [chars] is looped back to the same 
switch 

Explanation    The interface is looped back to another interface on the same switch

Recommended Action    Check the connectivity of this interface and ensure that it is connected to another switch

ETH-PORT-SEC Messages

This section contains the ETH-PORT-SEC messages.

ETH-PORT-SEC-2

Error Message    ETH-PORT-SEC-2-ETH_PORT_SEC_SECURITY_VIOLATION_ANOTHER_PORT: Host 
[chars] bound to Port [chars] in Vlan [dec] is trying to access Port [chars] in 
Vlan [dec] 

Explanation    Moved the port to violation state due to a mac address seen on one port being seen on another

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-2-ETH_PORT_SEC_SECURITY_VIOLATION_MAX_MAC_VLAN: Port 
[chars] moved to [chars] state as host [chars] is trying to access the port in 
vlan [dec] 

Explanation    Moved the port to violation state due to exceeding address count

Recommended Action    No action is required.

ETH-PORT-SEC-3

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_CONFIG_MAC_FAILED: Failed to configure 
MACs 

Explanation    Failed to configure MACs

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_INVALID_VLAN: Invalid VLAN configuration 

Explanation    Invalid VLAN configuration

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_DISABLE: Unable to disable 
eth_port_sec [chars]. 

Explanation    Unable to disable eth_port_sec Service

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_ENABLE: Unable to enable 
eth_port_sec [chars]. 

Explanation    Unable to enable eth_port_sec Service

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-3-ETH_PORT_SEC_VIOL_UPDATE_FAILED: Failed to update 
violation mode 

Explanation    Failed to update violation mode

Recommended Action    No action is required.

ETH-PORT-SEC-5

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_AGE_TIME_EXPIRY: Age Time expired for 
host [chars] in VLAN [dec] in port [chars] 

Explanation    Age time expired for host

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_DISABLED: eth_port_sec Disabled on port 
[chars] 

Explanation    Eth_port_sec Service Disabled

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_DYNAMIC_MAC_ADDRESS_CLEARED: Dynamic MAC 
addresses for port [chars] cleared 

Explanation    Dynamic MAC address for port cleared

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_ENABLED: eth_port_sec Enabled on port 
[chars] 

Explanation    Eth_port_sec Service Enabled

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_ADDITION: A new Host [chars] learnt 
on Port [chars] in Vlan [dec] 

Explanation    A new host is learnt on a port

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_DELETION: Host [chars] bound to 
secure port [chars] in Vlan [dec] has been removed 

Explanation    A host has been removed

Recommended Action    No action is required.

Error Message     ETH-PORT-SEC-5-ETH_PORT_SEC_MAX_LIMIT_EXCEED: Max Addr per port 
config cannot be accepted as it will violate the System Max limit. [chars] 

Explanation    System wide Max Limit Exceeds

Recommended Action    No action is required.

ETHPORT Messages

This section contains the ETHPORT messages.

ETHPORT-2

Error Message    ETHPORT-2-IF_CRITICAL_FAILURE: (Debug syslog)Critical failure: 
[chars], [chars] 

Explanation    There was a critical failure in the component.

Recommended Action    Please follow instructions on the syslog.

Error Message     ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error 
disabled. Reason:[chars]) 

Explanation    The interface encountered an error while configuring it

Recommended Action    Collect more information about failed interface using command 'show port internal all interface [char]'. In most cases, you can recover using a 'shutdown' followed a 'no shutdown' on the interface or removing and re-inserting the fibre optic cable.

Error Message     ETHPORT-2-IF_ERROR_SHUT_LAN_NO_DCX: Shutting lan on interface [chars] 
that doesn't connect to a DCBX capable adaptor. 

Explanation    Shutting lan on interface that doesn't connect to a DCBX capable adaptor.

Recommended Action    No action is required.

Error Message     ETHPORT-2-IF_SEQ_ERROR: Error ([chars]) while communicating with 
component [chars] for opcode [chars] ([chars]) 

Explanation    Some component returned system error as a response to one of the port event sequence.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETHPORT-2-SEQ_TIMEOUT: Component [chars] timed out on response to 
opcode [chars] ([chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETHPORT-2-SYSLOG_ETHPM_CRITICAL: Critical failure: [chars] 

Explanation    There was a critical failure in the component.

Recommended Action    Please collect system tech-support

ETHPORT-3

Error Message     ETHPORT-3-IF_DOWN_CHANNEL_ERR_DISABLED: Interface [chars] is down 
(Channel error disabled) 

Explanation    This interface belongs to a PortChannel and the PortChannel is error disabled

Recommended Action    Perform 'shut' and 'no shutdown' on the PortChannel interface that it belongs to

Error Message     ETHPORT-3-IF_ERROR_VLANS_REMOVED: VLANs [chars] on Interface [chars] 
are removed from suspended state. 

Explanation    The VLANs on an interface are being removed from the suspended state

Recommended Action    No action is required.

Error Message     ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs [chars] on Interface 
[chars] are being suspended. (Reason: [chars]) 

Explanation    The VLANs on an interface are being suspended due to some protocol action

Recommended Action    No action is required.

Error Message     ETHPORT-3-IF_SFP_ALARM: Interface [chars], [chars] 

Explanation    There was an alarm on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     ETHPORT-3-IF_SFP_ERROR: Interface [chars], [chars] 

Explanation    There was an error on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

Error Message     ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER_VENDOR: Transceiver vendor 
([hex] [hex] [hex]) for interface [chars] is not supported 

Explanation    The transceiver vendor for the interface specified in the error message is not supported

Recommended Action    Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced

Error Message     ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver on interface 
[chars] is not supported 

Explanation    The transceiver for the interface specified in the error message is not a Cisco supported module

Recommended Action    Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced

ETHPORT-4

Error Message     ETHPORT-4-IF_SFP_WARNING: Interface [chars], [chars] 

Explanation    There was an warning on the transceiver module

Recommended Action    Please do show interface transceiver details to obtain more information

ETHPORT-5

Error Message     ETHPORT-5-IF_BANDWIDTH_CHANGE: Interface [chars],bandwidth changed to 
[chars] Kbit 

Explanation    Bandwidth of the interface (port channel) has changed and this change is updated

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is down 
(Administratively down) 

Explanation    Interface has been configured to be administratively down

Recommended Action    Perform 'no shutdown'

Error Message     ETHPORT-5-IF_DOWN_CFG_CHANGE: Interface [chars] is down(Config 
change) 

Explanation    FCIP interface temporarily down due to reconfiguration

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_CHANNEL_ADMIN_DOWN: Interface [chars] is down 
(Channel admin down) 

Explanation    This interface belongs to a PortChannel and the PortChannel is configured to be administratively down

Recommended Action    Perform 'no shutdown' on the PortChannel interface that it belongs to

Error Message     ETHPORT-5-IF_DOWN_CHANNEL_MEMBERSHIP_UPDATE_IN_PROGRESS: Interface 
[chars] is down (Channel membership update in progress) 

Explanation    The interface belongs to a PortChannel and a configuration is being attempted on the interface while there is a configuration in progress on the PortChannel

Recommended Action    Retry the configuration again

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_ADDR_ASSIGN_FAILURE_ISOLATION: Interface 
[chars] is down (Isolation due to domain id assignment failure) 

Explanation    Isolated due to a failure while assigning a domain

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_INVALID_RCF_RECEIVED: Interface [chars] is 
down (Isolation due to invalid fabric reconfiguration) 

Explanation    Invalid RCF received

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED: Interface [chars] is down 
(Isolation due to domain manager disabled) 

Explanation    Isolated due to domain manager being disabled

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE: Interface 
[chars] is down (Isolation due to domain manager other side not responding) 

Explanation    Remote end domain manager not responding

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED: Interface 
[chars] is down (Isolation due to domain other side eport isolated) 

Explanation    Isolating this interface due to the remote end being isolated

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION: Interface [chars] is down 
(Isolation due to domain overlap) 

Explanation    Isolated due to domain overlap

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ELP_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ELP failure) 

Explanation    ELP failed on the interface

Recommended Action    Check the output of 'show port internal info' in the 'ELP failure reason' field

Error Message     ETHPORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error 
Disabled - EPP Failure) 

Explanation    Trunk protocol failed

Recommended Action    'show port internal event-history msgs' will indicate the trunk protocol exchanges to determine why it failed

Error Message     ETHPORT-5-IF_DOWN_ESC_FAILURE_ISOLATION: Interface [chars] is down 
(Isolation due to ESC failure) 

Explanation    ESC failed on the interface

Recommended Action    Check the output of 'show port internal event-history' to determine the ESC protocol exchanges to determine how it failed

Error Message     ETHPORT-5-IF_DOWN_ETH_IF_DOWN: Interface [chars] is down(Tunnel port 
src interface down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected, the interface is administratively enabled

Error Message     ETHPORT-5-IF_DOWN_ETH_LINK_DOWN: Interface [chars] is down(Tunnel 
port src interface link down) 

Explanation    Ethernet link to which the FCIP interface is bound is down

Recommended Action    Ensure that the ethernet cable is connected and the remote end is also active

Error Message     ETHPORT-5-IF_DOWN_FCOT_NOT_PRESENT: Interface [chars] is down (FCOT 
not present) 

Explanation    The FCOT has been removed

Recommended Action    Insert an FCOT

Error Message     ETHPORT-5-IF_DOWN_FCOT_VENDOR_NOT_SUPPORTED: Interface [chars] is 
down (Error disabled - Fcot vendor not supported) 

Explanation    Fcot inserted is not a supported one

Recommended Action    Please contact customer support for a list of authorized transceiver vendors

Error Message     ETHPORT-5-IF_DOWN_HW_FAILURE: Interface [chars] is down (Hardware 
Failure) 

Explanation    The module's hardware has failed

Recommended Action    Collect more information about failed module using command 'show module internal all module'

Error Message     ETHPORT-5-IF_DOWN_INACTIVE: Interface [chars] is down (Inactive) 

Explanation    The port VSAN has been suspended or deleted

Recommended Action    Assign a new active port VSAN to the interface

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_MODE: Interface [chars] is down 
(Error disabled - Incompatible admin port mode) 

Explanation    The configured mode is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the list of modes supported on this interface

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBBCREDIT: Interface [chars] 
is down (Error disabled - Incompatible admin port rxbbcredit) 

Explanation    The configured receive B2B credit size is not supported

Recommended Action    Get the allowed receive B2B credit size from 'show port internal info'

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBUFSIZE: Interface [chars] is 
down (Error disabled - Incompatible admin port rxbufsize) 

Explanation    The configured receive buffer size is not supported

Recommended Action    Get the allowed receive buffer size from 'show port internal info'

Error Message     ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_SPEED: Interface [chars] is down 
(Error disabled - Incompatible admin port speed) 

Explanation    The configured speed is not supported on this interface

Recommended Action    Perform a 'show port internal info' to determine the range of speed supported on this interface

Error Message     ETHPORT-5-IF_DOWN_INITIALIZING: Interface [chars] is down 
(Initializing) 

Explanation    The interface is in the process of coming up

Recommended Action    If the interface is stuck in this state for a while, check the output of 'show port internal event-history' to determine what it is waiting for

Error Message     ETHPORT-5-IF_DOWN_INTERFACE_REMOVED: Interface [chars] is down 
(Interface removed) 

Explanation    Interface removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface [chars] is down (Link 
failure) 

Explanation    The physical link has gone down

Recommended Action    Ensure that the cable is connected and the remote end is not shut down

Error Message     ETHPORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE: Interface [chars] is down 
(Diag failure) 

Explanation    Diag failed on the interface

Recommended Action    Collect more information about failed interface using command 'attach module' to connect to module

Error Message     ETHPORT-5-IF_DOWN_LOOPBACK_ISOLATION: Interface [chars] is down 
(Isolation due to port loopback to same switch) 

Explanation    The interface is looped back to another interface on the same switch

Recommended Action    Check the connectivity of this interface and ensure that it is connected to another switch

Error Message     ETHPORT-5-IF_DOWN_MODULE_REMOVED: Interface [chars] is down (module 
removed) 

Explanation    Interface is down because the module was removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_NONE: Interface [chars] is down (None) 

Explanation    There is no apparent reason the interface is down

Recommended Action    Collect more information about port using command 'show port internal info/event-history' to determine why it went down

Error Message     ETHPORT-5-IF_DOWN_NON_PARTICIPATING: Interface [chars] is down (Non 
participating) 

Explanation    The loop port has been put into non participating mode

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_OFFLINE: Interface [chars] is down (Offline) 

Explanation    The interface has been placed into the offline state

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PARENT_ADMIN_DOWN: Interface [chars] is down 
(Parent interface down) 

Explanation    Parent interface is down

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PEER_CLOSE: Interface [chars] is down(TCP conn. 
closed by peer) 

Explanation    The FCIP peer connected to this interface closed the TCP connection

Recommended Action    This command will provide the peer IP address of this FCIP interface: show interface. Check to see why the peer closed the TCP connection

Error Message     ETHPORT-5-IF_DOWN_PEER_RESET: Interface [chars] is down(TCP conn. 
reset by peer) 

Explanation    TCP connection to the FCIP peer got reset

Recommended Action    The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Check to see why the peer reset the TCP connection

Error Message     ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface [chars] is 
down (No operational members) 

Explanation    This is a PortChannel interface and all its members are operationally down

Recommended Action    Enable at least one of the PortChannel's members

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_DEINHERIT_ERR: Interface [chars] is 
down (port-profile de-inherit error) 

Explanation    Interface is down because the existing port-profile on the interface failed to de-inherit properly

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_INHERIT_ERR: Interface [chars] is down 
(port-profile inherit error) 

Explanation    Interface is down because the associated port-profile failed to inherit properly

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_PROFILE_NOT_FOUND: Interface [chars] is down 
(port-profile not found) 

Explanation    Interface is down because there is no associated port-profile

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_PORT_VSAN_MISMATCH_ISOLATION: Interface [chars] is 
down (Isolation due to port vsan mismatch) 

Explanation    Isolated due to a mismatch in the configured port VSAN of the local and remote ends

Recommended Action    Configure the port VSAN of the local and remote interfaces to be the same and perform a 'shutdown' and a 'no shutdown'

Error Message     ETHPORT-5-IF_DOWN_RCF_IN_PROGRESS: Interface [chars] is down (RCF in 
progress) 

Explanation    There is an RCF in progress

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface [chars] is down (Port 
software failure) 

Explanation    The software servicing the data path on the port has failed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SRC_MOD_NOT_ONLINE: Interface [chars] is 
down(Tunnel source module not online) 

Explanation    Module that has the tunnel source port of this FCIP interface is not fully online

Recommended Action    The module that has the tunnel src port is coming online. Please use show mod to find module status

Error Message     ETHPORT-5-IF_DOWN_SRC_PORT_NOT_BOUND: Interface [chars] is down 
(Tunnel port src interface unbound) 

Explanation    Tunnel port source interface unbound

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_SRC_PORT_REMOVED: Interface [chars] is down(Tunnel 
src port removed) 

Explanation    Tunnel source port of this FCIP interface has been removed

Recommended Action    The src interface with ip address that matches the ip address of the bound entity is removed. This happens normally due to the module on which the src interface exists is removed

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down 
(Suspended due to incompatible mode) 

Explanation    This interface belongs to a PortChannel and operational mode of the interface is different from that of the PortChannel

Recommended Action    Change the mode and the trunking mode of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down 
(Suspended due to incompatible speed) 

Explanation    This interface belongs to a PortChannel and operational speedode of the interface is different from that of the PortChannel

Recommended Action    Change the speed of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED_BY_WWN: Interface [chars] is down 
(Suspended due to incompatible remote switch WWN) 

Explanation    This interface belongs to a PortChannel and remote switch WWN of the interface is different from that of the PortChannel

Recommended Action    Ensure that this interface is connected to the same remote switch as all the other interfaces in the PortChannel

Error Message     ETHPORT-5-IF_DOWN_SUSPENDED: Interface [chars] is down (Suspended) 

Explanation    This interface belongs to a PortChannel and has been suspended due to an error while bringing it up

Recommended Action    Perform a 'shutdown' and a 'no shutdown'. If this happens again obtain output of 'show port internal info/event-history' on the interface

Error Message     ETHPORT-5-IF_DOWN_TCP_KEEP_ALIVE_EXPIRED: Interface [chars] is 
down(TCP conn. closed - Keep alive expired) 

Explanation    TCP session to the FCIP peer got closed due to loss of TCP keep alive

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_TCP_MAX_RETRANSMIT: Interface [chars] is down(TCP 
conn. closed - retransmit failure) 

Explanation    Interface is down due to maximum retransmission failure

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_TCP_PERSIST_TIMER_EXPIRED: Interface [chars] is 
down(TCP conn. closed - Persist timer expired) 

Explanation    TCP session to the FCIP peer closed because TCP persist timer expired

Recommended Action    This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr

Error Message     ETHPORT-5-IF_DOWN_UPGRADE_IN_PROGRESS: Interface [chars] is down 
(Linecard upgrade in progress) 

Explanation    Upgrade of the linecard software is in progress

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VEM_UNLICENSED: Interface [chars] is down (VEM 
unlicensed) 

Explanation    Interface is down because VEM is unlicensed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VRF_UNUSABLE: Interface [chars] is down (Vrf down) 

Explanation    The vrf for which this interface is a member is removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION: Interface [chars] is down 
(Isolation due to vsan mismatch) 

Explanation    This is a trunking interface and the VSANs configured do not match with the VSANs configured on the remote end

Recommended Action    Check the VSANs configured on the local end with the remote end

Error Message     ETHPORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION: Interface [chars] is 
down (Isolation due to zone merge failure) 

Explanation    Isolated due to a failure during zone merge

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION: Interface [chars] 
is down (Isolation due to remote zone server not responding) 

Explanation    Isolated due to remote zone server not responding

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_DUPLEX: Interface [chars], operational duplex mode 
changed to [chars] 

Explanation    Operational duplex mode has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_HARDWARE: Interface [chars], hardware type changed to 
[chars] 

Explanation    There was a change in the hardware characteristic of an interface, such as a transceiver module plugged in or removed

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_RX_FLOW_CONTROL: Interface [chars], operational Receive 
Flow Control state changed to [chars] 

Explanation    Operational receive flow control has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_TRUNK_DOWN: Interface [chars], vlan [chars] down 

Explanation    Interface [chars] is trunking, VLANs [chars] are down

Recommended Action    The following commands will help determine why this VSAN is down on this interface: show interface, show port internal info interface VSAN, show port internal event-history interface vsan

Error Message     ETHPORT-5-IF_TRUNK_UP: Interface [chars], vlan [chars] up 

Explanation    Interface [chars] is trunking, VLANs [chars] are up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_TX_FLOW_CONTROL: Interface [chars], operational Transmit 
Flow Control state changed to [chars] 

Explanation    Operational transmit flow control has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-IF_UP: Interface [chars] is up [chars] 

Explanation    Interface is up in mode specified, if applicable

Recommended Action    No action is required.

Error Message     ETHPORT-5-SPEED: Interface [chars], operational speed changed to 
[chars] 

Explanation    Operational speed has changed when link came up

Recommended Action    No action is required.

Error Message     ETHPORT-5-STORM_CONTROL_ABOVE_THRESHOLD: Traffic in port [chars] 
exceeds the configured threshold [chars] 

Explanation    Traffic on specified port is beyond the configured storm-control threshold, and the excess traffic is being dropped

Recommended Action    Identify source of traffic storm

Error Message     ETHPORT-5-STORM_CONTROL_BELOW_THRESHOLD: Traffic in port [chars] has 
fallen below the configured threshold [chars] 

Explanation    Traffic on specified port has returned to within configured storm-control threshold

Recommended Action    No action is required.

ETH_PORT_CHANNEL Messages

This section contains the ETH_PORT_CHANNEL messages.

ETH_PORT_CHANNEL-1

Error Message    ETH_PORT_CHANNEL-1-LC_CFG_FAILURE: configuring module [dec] failed 
[[chars]] 

Explanation    Module configuration failed

Recommended Action    Module will be automatically reset

Error Message     ETH_PORT_CHANNEL-1-MALLOC_FAILED: cannot allocate memory (size [dec]) 

Explanation    No enough memory

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-1-MAP_PARAM_FAILURE: mapping parameter failed for 
[chars] [[chars]] 

Explanation    Parameter mapping failed

Recommended Action    Specified service is misbehaving; check its status

Error Message     ETH_PORT_CHANNEL-1-MCAST_SEND_FAILURE: failed to send multicast 
[chars]: [chars] 

Explanation    Failed to send a multicast message to all modules, usually because some module went down

Recommended Action    Run show port-channel consistency to check consistency

ETH_PORT_CHANNEL-2

Error Message     ETH_PORT_CHANNEL-2-RESET_MODULE: reset module [dec] for not 
responding or returning error 

Explanation    A module is reset for not responding or returning error

Recommended Action    No action is required.

ETH_PORT_CHANNEL-3

Error Message     ETH_PORT_CHANNEL-3-ALL_DROP_TIMEOUT: Some component(s) timed out on 
dropping notif:[chars] (for:[chars]); Please collect <show system internal mts 
buffers details> 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-COMPAT_CHECK_FAILURE: [chars] is not compatible 

Explanation    Compatibility check failed when adding ports to port-channel

Recommended Action    Make sure the compatibility parameters are consistent while adding ports to port-channel, or use force option

Error Message     ETH_PORT_CHANNEL-3-GENERAL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-LACP_ERROR: [chars] [chars] 

Explanation    LACP error

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send [chars] to sap 
[dec]: [chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-NUM_ACTIVE_PORTS_ERROR: Port-channel:[chars] 
active_nports [dec]; No member is active; Please collect <show tech-support 
port-channel/ethpm> 

Explanation    Port-channel num active ports error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_HWCFG_FAIL_ERROR: Port-channel:[chars] 
mbr:[chars] SAP [dec] returned error [chars] for opc [chars]; if lacp port-channel 
please collect <show tech-support lacp all> or please collect <show tech-support 
port-channel/ethpm>

Explanation    Port-channel hwcfg fail error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_INTERNAL_ERROR: Port-channel:[chars] 
mbr:[chars]; if lacp port-channel please collect <show tech-support lacp all> or 
please collect <show tech-support port-channel/ethpm>

Explanation    Port-channel internal error

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PCM_PORT_DOWN_IN_PC_UP_ERROR: 
Port-channel:[chars] mbr:[chars]; if lacp port-channel please collect <show 
tech-support lacp all> or please collect <show tech-support port-channel/ethpm>

Explanation    Port-channel port down in pc_up. No bundle member down

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-PORT_CHANNEL_NOT_FOUND: [chars] is not found 

Explanation    Cannot find port-channel in its database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-3-RSP_TIMEOUT: Component [chars] timed out on 
response to opcode:[chars] (for:[chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     ETH_PORT_CHANNEL-3-TIMEOUT: timed out after [dec] seconds [type 
[chars], state [chars]] 

Explanation    Some operation timed out

Recommended Action    Run show port-channel consistency to check all module connectivity and consistency

ETH_PORT_CHANNEL-4

Error Message     ETH_PORT_CHANNEL-4-PORT_CFG_DELETED: [chars] removed from [chars] 
(different module inserted) 

Explanation    Port is removed from a port-channel because a different module was inserted to the same slot

Recommended Action    You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.

Error Message     ETH_PORT_CHANNEL-4-PORT_INDIVIDUAL: port [chars] is operationally 
individual 

Explanation    The port is operating as an individual link even though it is locally or remotely configured to be part of a port channel

Recommended Action    Check the configuration of the port locally and remotely to ensure that it can operate as part of a port channel

Error Message     ETH_PORT_CHANNEL-4-PORT_NOT_FOUND: port [chars] is not part of 
port-channel 

Explanation    Cannot find the port in port-channel database, which indicates an inconsistency with an external component

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-4-RACE_WARN: [chars] 

Explanation    Warning of possible race condition

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-4-UNEXPECTED_RESPONSE: unexpected response [chars] 
from [chars] 

Explanation    Received an unexpected response and discarded

Recommended Action    No action is required.

ETH_PORT_CHANNEL-5

Error Message     ETH_PORT_CHANNEL-5-AUTO_CREATE_FAILURE: [chars] [chars] 

Explanation    Auto create process on the port failed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-CREATED: [chars] created 

Explanation    A port-channel is created

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-DELETED: [chars] deleted 

Explanation    A port-channel is deleted

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-FOP_CHANGED: [chars]: first operational port 
changed from [chars] to [chars] 

Explanation    The first operational port in a port-channel is changed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is 
down (Suspended due to incompatible mode 

Explanation    Compatibility check failed when adding ports to port-channel

Recommended Action    Make sure the compatibility parameters are consistent between the ports and the port-channel

Error Message     ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is 
down (Suspended due to incompatible speed 

Explanation    Operational compatibility check failed on the port in a port-channel

Recommended Action    Make sure the compatibility parameters are consistent between the ports and the port-channel

Error Message     ETH_PORT_CHANNEL-5-MAX_CHANNEL_DISALLOWED: Module failed to come 
online because port channel interface <port-channel number> greater than [dec] is 
present 

Explanation    The port-channel number configured on the switch is larger than 128

Recommended Action    Delete the set of port channel interface <port-channel interface> which is greater than 128

Error Message     ETH_PORT_CHANNEL-5-OPINPROGRESS_TIMEOUT: [chars] operation in 
progress has timed out 

Explanation    Port-channel operation in progress has timed out

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PCM_CHANNEL_GRP_ID_DEPRECATED: channel-group <id> 
command is deprecated. Please configure channel through port-profile using 
channel-group auto command. 

Explanation    Channel-group <id> command is deprecated. Please configure channel through port-profile using \channel-group auto\ command.

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PCM_ROLLBACK_MAX_PORTS_EXCEEDED: Max ports per 
channel exceeded while trying to create port-channel [dec]. Rollback will be 
performed. 

Explanation    No action is required.

Recommended Action    Port-channel

Error Message     ETH_PORT_CHANNEL-5-PCM_ROLLBACK: Rollback for Port Channel [dec], 
module [dec] 

Explanation    Channel creation failed. Rollback has been performed.

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_ADDED: [chars] added to [chars] 

Explanation    Ports are added to a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_DOWN: [chars]: [chars] is down 

Explanation    Port goes down in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY_DOWN: [chars]: hot-standby port 
[chars] is down 

Explanation    Port-channel hot-standby member goes down

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY: [chars]: [chars] goes to 
hot-standby 

Explanation    Port goes to hot-standby in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_INDIVIDUAL_DOWN: individual port [chars] is 
down 

Explanation    Port-channel member operating in individual mode goes down

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_REMOVED: [chars] removed from [chars] 

Explanation    Ports are removed from a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_SUSPENDED: [chars]: [chars] is suspended 

Explanation    Port is suspended in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-PORT_UP: [chars]: [chars] is up 

Explanation    Port comes up in a port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_CHANGE: Interface [chars] in 
port-channel[dec] subgroup-id changed from [dec] to [dec] 

Explanation    The port's subgroup-id got changed

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_ADDED: Interface [chars] is added 
to port-channel[dec] with subgroup id [dec] 

Explanation    The port is added to port-channel

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_REMOVED: Interface [chars] is 
removed from port-channel[dec] with subgroup id [dec] 

Explanation    The port is removed from port-channel

Recommended Action    No action is required.

ETH_PORT_CHANNEL-6

Error Message     ETH_PORT_CHANNEL-6-RESYNC: resyncing [chars] with all modules 

Explanation    Resync modules with sup after an error or switchover

Recommended Action    No action is required.

ETH_PORT_CHANNEL-7

Error Message     ETH_PORT_CHANNEL-7-GSYNC_DONE: global synchronization is done 

Explanation    Port-channel manager finished global synchronization

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-GSYNC_REQ: requesting global synchronization 

Explanation    Port-channel manager requested a global synchronization from active sup

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_ACTIVE: started in active mode 

Explanation    Port-channel manager started in active mode

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_DEFAULT: started with default configuration 

Explanation    Port-channel manager started with default configuration

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STANDBY: started in standby mode 

Explanation    Port-channel manager started in standby mode

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STATEFUL: started statefully 

Explanation    Port-channel manager started with running configuration

Recommended Action    No action is required.

Error Message     ETH_PORT_CHANNEL-7-START_STATELESS: started statelessly 

Explanation    Port-channel manager started with startup configuration

Recommended Action    No action is required.

EUREKA_USD Messages

This section contains the EUREKA_USD messages.

EUREKA_USD-3

Error Message    EUREKA_USD-3-MSG1: [chars] 

Explanation    Eureka log message

Recommended Action    No action is required.

EVMC Messages

This section contains the EVMC messages.

EVMC-5

Error Message    EVMC-5-AVL_CREATE_FAIL: [chars]([dec]): AVL Tree creation failure 

Explanation    Event Manager could not initialize local policy store

Recommended Action    No action is required.

Error Message     EVMC-5-MALLOC_FAILURE: [chars]([dec]): Memory allocation failure 

Explanation    Event Manager Client process could not allocate memory

Recommended Action    No action is required.

Error Message     EVMC-5-RT_PSS_OP_FAILURE: [chars]([dec]): Failed to [chars]. 
Error:[chars] 

Explanation    Event Manager Client could access HA store

Recommended Action    No action is required.

EVMS Messages

This section contains the EVMS messages.

EVMS-2

Error Message    EVMS-2-EVMS_PSS_DELETE_FAILURE: Delete from PSS failed 

Explanation    Delete from PSS failed

Recommended Action    No action is required.

Error Message     EVMS-2-EVMS_PSS_WRITE_FAILURE: Write to PSS failed 

Explanation    Write to PSS failed

Recommended Action    No action is required.

Error Message     EVMS-2-EVMS_SHOW_POLICY_ALLOC_FAILURE: Insufficient memory: policy 
information shown will be incomplete 

Explanation    Memory allocation failed. so complete requested information is not being shown

Recommended Action    No action is required.

EVMS-4

Error Message     EVMS-4-EVMS_APPLET_NO_ACTION_DEFAULT: WARNING: The default system 
policy actions are being skipped 

Explanation    The default system policy actions are being skipped

Recommended Action    No action is required.

EXCEPTIONLOG Messages

This section contains the EXCEPTIONLOG messages.

EXCEPTIONLOG-SLOT#-2

Error Message    EXCEPTIONLOG-SLOT#-2-LC_EXP_MSG: Linecard exception: [chars] is the 
affected Port bit map. [dec] Additional information - [chars] 

Explanation    LC Exception event.

Recommended Action    No action is required.

FC-TUNNEL Messages

This section contains the FC-TUNNEL messages.

FC-TUNNEL-3

Error Message    FC-TUNNEL-3-INTERNAL_ERROR: Internal error: [chars] 

Explanation    FCMPLS tunnel process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-IPFC_ERROR: IPFC API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked IPFC API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-MTS_ERROR: MTS message transmission failed with error 
[dec] 

Explanation    FCMPLS tunnel process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-NS_ERROR: FCNS API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PM_ERROR: Port Manager API, [chars], failed with error 
[hex] 

Explanation    FCMPLS tunnel invoked Port Manager API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for 
[chars] failed with error [hex] 

Explanation    FCMPLS tunnel read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system error code

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_ERROR: PSS operation [chars] returned error: [hex] 

Explanation    [chars] specifies the context where the failure occurred and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    FCMPLS tunnel read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-RIB_ERROR: RIB API, [chars], failed with error [hex] 

Explanation    FCMPLS tunnel invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-RSVP_PROTO_ERROR: RSVP protocol error: [chars] 

Explanation    RSVP-TE protocol error is encountered. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FC-TUNNEL-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], 
is received 

Explanation    FCMPLS tunnel process received unexpected MTS event. MTS opcode is specified in [dec]

Recommended Action    No action is required.

FC-TUNNEL-5

Error Message     FC-TUNNEL-5-MSG_INTERFACE_DOWN: Interface [chars] is down 

Explanation    The logical fc tunnel interface is down. This may be due to a reconfiguration on the fc tunnel, or issues on the underlying physical interface

Recommended Action    If this is not due to a known reconfiguration, you should verify connectivity at the physical port level, and then on then on the fc tunnel interface. Furthermore, verify the physical ports along the fc tunnel path operate in the TE mode

Error Message     FC-TUNNEL-5-MSG_INTERFACE_UP: Interface [chars] is up 

Explanation    The fc interface is up

Recommended Action    No action is required.

FCC_LC Messages

This section contains the FCC_LC messages.

FCC_LC-2

Error Message    FCC_LC-2-ERROR_SENDING_HEART_BEAT: Error sending heart beat [dec] 

Explanation    FCC_LC has error sending heart beat

Recommended Action    No action is required.

Error Message     FCC_LC-2-EXITING: Exiting fcc_lc: [chars] 

Explanation    FCC_LC exiting

Recommended Action    No action is required.

Error Message     FCC_LC-2-HEART_BEAT_NOT_SENT: Heart beat not sent for [dec] millisecs 

Explanation    FCC_LC has not sent heart beat

Recommended Action    No action is required.

Error Message     FCC_LC-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    FCC_LC Process is shutting down

Recommended Action    No action is required.

Error Message     FCC_LC-2-UNABLE_READ_DATA: Unable to read fcc data ([chars]) 

Explanation    FCC is unable to read and process relevant FCC data

Recommended Action    No action is required.

FCC_LC-5

Error Message     FCC_LC-5-BAD_MSG: Received bad message: [chars] 

Explanation    FCC_LC has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     FCC_LC-5-DISABLE: FCC_LC has been disabled 

Explanation    FCC_LC has been disabled

Recommended Action    No action is required.

Error Message     FCC_LC-5-ENABLE: FCC_LC has been enabled 

Explanation    FCC_LC has been enabled

Recommended Action    No action is required.

Error Message     FCC_LC-5-STARTING: FCC_LC process started 

Explanation    Process started successfully

Recommended Action    No action is required.

Error Message     FCC_LC-6-PRIO_UPDATE: Updated enable priority to [dec] 

Explanation    FCC_LC is active for packets with priority <= [threshold]

Recommended Action    No action is required.

Error Message     FCC-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    FCC Process is shutting down

Recommended Action    No action is required.

FCC-5

Error Message     FCC-5-BAD_MSG: Received bad message: [chars] 

Explanation    FCC has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     FCC-5-CONGESTION_STATE_CHANGE_NOTIF: Received Congestion State Change 
notification to state: [dec] 

Explanation    FCC has received a Contestion State Change Notification

Recommended Action    No action is required.

Error Message     FCC-5-DISABLE: FCC has been disabled 

Explanation    FCC has been disabled

Recommended Action    No action is required.

Error Message     FCC-5-ENABLE: FCC has been enabled 

Explanation    FCC has been enabled

Recommended Action    No action is required.

Error Message     FCC-5-RATE_LIMIT_END_NOTIF: Received Rate Limit End notification 

Explanation    FCC has received a Rate Limit End Notification

Recommended Action    No action is required.

Error Message     FCC-5-RATE_LIMIT_START_NOTIF: Received Rate Limit Start notification 

Explanation    FCC has received a Rate Limit Start Notification

Recommended Action    No action is required.

Error Message     FCC-5-STARTING: FCC process started 

Explanation    Process started successfully

Recommended Action    No action is required.

FCC-6

Error Message     FCC-6-PRIO_UPDATE: Updated enable priority to [dec] 

Explanation    FCC is active for packets with priority <= [threshold]

Recommended Action    No action is required.

FCDDH Messages

This section contains the FCDDH messages.

FCDDH-SLOT#-3

Error Message    FCDDH-SLOT#-3-LOG_FCDDH_ERR: Nonrecoverable error - exiting: [chars] 

Explanation    Errors which cause program to exit occurred

Recommended Action    No action is required.

FCDDH-SLOT#-4

Error Message     FCDDH-SLOT#-4-LOG_FCDDH_WARNING: Serious error: [chars] 

Explanation    Serious errors which affect all normal operations occurred

Recommended Action    No action is required.

FCDDH-SLOT#-5

Error Message     FCDDH-SLOT#-5-LOG_FCDDH_DEBUG: Unexpected error: [chars] 

Explanation    Unexpected errors which affect some normal operations occurred

Recommended Action    No action is required.

Error Message     FCDDH-SLOT#-5-LOG_FCDDH_NOTICE: [chars] 

Explanation    Major configuration changes

Recommended Action    No action is required.

FCDD Messages

This section contains the FCDD messages.

FCDD-SLOT#-3

Error Message    FCDD-SLOT#-3-LOG_FCDD_ERR: Nonrecoverable error - exiting: [chars] 

Explanation    Errors which cause program to exit occurred

Recommended Action    No action is required.

FCDD-SLOT#-4

Error Message     FCDD-SLOT#-4-LOG_FCDD_WARNING: Warning!: [chars] 

Explanation    Serious errors which affect all normal operations occurred

Recommended Action    No action is required.

FCDD-SLOT#-5

Error Message     FCDD-SLOT#-5-LOG_FCDD_GCONF_FSM: [chars] 

Explanation    Illegal event received in Global Configuration FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_NOTICE: [chars] 

Explanation    Major configuration changes

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_RESCAN_FSM: [chars] 

Explanation    Illegal event received in Rescan FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_TZONE_FSM: [chars] 

Explanation    Illegal event received in Twilight Zone Remover FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_VCONF_FSM: [chars] 

Explanation    Illegal event received in VSAN Configuration FSM

Recommended Action    No action is required.

Error Message     FCDD-SLOT#-5-LOG_FCDD_VNO_FSM: [chars] 

Explanation    Illegal event received in VSAN Normal Operation FSM

Recommended Action    No action is required.

FCDD-SLOT#-7

Error Message     FCDD-SLOT#-7-LOG_FCDD_DEBUG: [chars] 

Explanation    Unexpected errors which affect some normal operations occurred

Recommended Action    No action is required.

FCDOMAIN Messages

This section contains the FCDOMAIN messages.

FCDOMAIN-2

Error Message    FCDOMAIN-2-DOMS_CONFLICT: Conflict detected: ([dec]) domain ID [dec] 
WWN [chars] 

Explanation    Conflict detected ([dec]) domain ID [dec] with WWN [chars].

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-EPORT_ISOLATED: Isolation of interface [chars] (reason: 
[chars]) 

Explanation    Fcdomain has isolated interface [chars] (reason: [chars].) Perform a show interface. Based on the reason specified, you might have to ensure domains are adequate and unique in the VSAN and perform a disruptive restart [fcdomain restart disruptive vsan <vsan-id>] or to reinitialize the port.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2BIND_FAILED: Bind to FC2 Service failed 

Explanation    Fcdomain has not been able to contact the FC2 module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2_INITIALIZATION_FAILED: FC initialization sequence 
failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the Fibre Channel subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FC2_SET_SOCKOPT_DM_SOCK_FAILED: set sockopt to FC2 Service 
failed 

Explanation    Fcdomain has not been able to setsockopt to the FC2 module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-FCID_PERSISTENT_TBL_COMPLETELY_FULL: FCID persistent 
table is completely full 

Explanation    The FCID persistent table is full. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table. No more entries can be saved as persistent FCIDs across reboots.

Recommended Action    Purge stale entries [purge fcdomain fcid] to obtain more free entries OR disable the feature on certain VSANs which are not critical enough [no fcdomain fcid persistent].

Error Message     FCDOMAIN-2-HIGH_PRIORITY_MTSBIND_FAILED: Bind for high priority IPC 
failed 

Explanation    Fcdomain has not been able to contact the Inter Process Communication (IPC) module for its high priority queue.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-INITIALIZATION_FAILED: Initialization sequence failed 

Explanation    The fcdomain has not been able to complete the initialization sequence. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTSBIND_FAILED: Bind to IPC failed 

Explanation    Fcdomain has not been able to contact the Inter Process Communication (IPC) module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTSREGISTRATION_FAILED: Registration of opcodes with IPC 
Service failed 

Explanation    Fcdomain has not been able to register its messages with the Inter Process Communication (IPC) module.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MTS_INITIALIZATION_FAILED: IPC initialization sequence 
failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the IPC (Inter Process Communication) subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-MY_NON_VIRTUAL_DOM_CONFLICTS: During VSAN merge detected 
that the local switch has the same domain ID [dec] and WWN [chars] of another 
switch 

Explanation    It has been detected that the local switch has the same domain ID [dec] and WWN [chars] of another switch.

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-NON_VIRTUAL_DOMS_CONFLICTS: During VSAN merge detected 
conflict between two switches having the same non-virtual domain ID [dec] and the 
same WWN [chars] 

Explanation    It has been detected that two switches have the same non-virtual domain ID [dec] and the same WWN [chars].

Recommended Action    Check which switches have the same WWN and change either one; then change either's domain ID.

Error Message     FCDOMAIN-2-PSSBIND_FAILED: Bind to Persistent Storage Service failed 

Explanation    Fcdomain has not been able to contact the Persistent Storage Service (PSS).

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-RDIRJT: Rejected request for domain ID [dec], WWN requestor 
[chars] (reason code [dec]) 

Explanation    An invalid request for domain IDs has been rejected by fcdomain.

Recommended Action    Perform [show fcdomain vsan <vsan-id>] for all the switches in the affected VSAN; if a switch does not have a valid current domain ID, configure preferred domain ID zero, then perform [fcdomain restart vsan <vsan-id>] in the affected VSAN.

Error Message     FCDOMAIN-2-SYSBIND_FAILED: Bind to System Manager service failed 

Explanation    Fcdomain has not been able to contact the System Manager.

Recommended Action    No action is required.

Error Message     FCDOMAIN-2-SYSMGR_INITIALIZATION_FAILED: System Manager 
initialization sequence failed 

Explanation    The fcdomain has not been able to complete the initialization sequence with the System Manager. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.

Recommended Action    No action is required.

FCDOMAIN-3

Error Message     FCDOMAIN-3-COMMITERRORLOCALINVALIDALLOWEDDOMS: A remote switch 
attempted to locally apply an illicit allowed domains configuration 

Explanation    A remote switch attempted to locally apply an allowed domains configuration that doesn't include all currently assigned domains or the locally configured domain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-COMMITERRORREMOTEINVALIDALLOWEDDOMS: A remote switch 
(domain ID [dec], WWN [chars]) refuses to locally apply the proposed allowed 
domains 

Explanation    The remote switch with domain ID [dec] and WWN [chars] refuses to locally apply the proposed allowed domains probably due to incompatibility with its local configured domain or the domain ID list.

Recommended Action    Check the configuration on the remote switch, and make sure that the proposed allowed domains include it. Also, make sure that the the proposed allowed domains include all the domains in the domain ID list.

Error Message     FCDOMAIN-3-MTSOPENTRX_FAILED: IPC failure (opening of a transaction 
failed) 

Explanation    Fcdomain was not able to open a transaction( HA Purposes.)

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-MTSRECV_FAILED: IPC failure (receiving of a message 
failed) 

Explanation    Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-MTSRESP_FAILED: IPC failure replying to a request message 
(error [hex]) 

Explanation    Fcdomain has not been able to reply to a request coming from the Inter Process Communication (IPC) module (error [hex]).

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive).

Error Message     FCDOMAIN-3-MTSSENDREQ_FAILED: IPC failure (sending of a request 
failed) 

Explanation    Fcdomain was not able to send a request using the Inter Process Communication module.

Recommended Action    Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-MTSSEND_FAILED: IPC failure (sending of a message (syserr 
[hex], opc [dec], mtsq [dec], sap.node [hex], sap_addr [dec]) failed) 

Explanation    Fcdomain has not been able to send a message to the Message Transactional Service (MTS).

Recommended Action    Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive).

Error Message     FCDOMAIN-3-MTS_H_RECV_FAILED: IPC failure (receiving of a message 
failed) 

Explanation    Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.

Recommended Action    Please perform fcdomain restart in the affected VSAN (non disruptive.)

Error Message     FCDOMAIN-3-NVRAMFAILURE: NVRAM open failed 

Explanation    Reading the last assigned runtime domain IDs from Non Volatile RAM (NVRAM) failed.

Recommended Action    Fcdomain is able to continue without access to the Non Volatile RAM (NVRAM.)

Error Message     FCDOMAIN-3-PORT_SUSPENDED: Response (Cmd Code [hex]) for SWILS [hex] 
intended for [chars] is received on [chars] 

Explanation    An FC2 response frame (Command Code [hex]) for SWILS [hex] that was intended for interface [chars] has been received on [chars] instead.

Recommended Action    Check the configuration of both interfaces on the local switch and the interfaces on the other side of their corresponding links. In particular, check whether they should all belong to the same port-channel.

Error Message     FCDOMAIN-3-SDWRAPBIND_FAILED: Bind to debug server failed 

Explanation    Fcdomain feature has not been able to contact the debug service. Any problems occurring in the fcdomain feature will not be logged.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-SDWRAPHISTINIT_FAILED: Initialization of history message 
list failed. 

Explanation    Fcdomain feature has not been able to contact the debug history service. Any problems occurring in the fcdomain feature will not be logged to this debug history.

Recommended Action    No action is required.

Error Message     FCDOMAIN-3-VSAN_MERGE_DETECTED: Merge detected with VSAN [dec] 
(Common Fabric Name [chars]) 

Explanation    The local VSAN and VSAN [dec] have the same principal switch [chars], hence are connected in the same logical fabric.

Recommended Action    No action is required.

FCDOMAIN-4

Error Message     FCDOMAIN-4-DM_ALLOWED_DM_LIST_MOD_ON_SUBORDINATE: Allowed domain 
list for vsan [dec] modified on subordinate switch with fcdomain distribution 
enabled 

Explanation    When distribution is enabled, it is recommended to modify the allow domain list on the principal switch only.

Recommended Action    Abort the current session on the local switch and start a new one on the principal switch.

Error Message     FCDOMAIN-4-FABRICCONFSTARTRCF: Disruptive reconfiguration started 

Explanation    A disruptive reconfiguration (RCF phase) of the VSAN has started. This can happen when two or more fabrics merge disruptively, or when the user manually triggers a diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-4-FC2_CORRUPTED: Received malformed FC2 [chars] frame 

Explanation    Fcdomain received a malformed FC2-SWILS frame.

Recommended Action    No action is required.

Error Message     FCDOMAIN-4-FCID_PERSISTENT_TBL_ALMOST_FULL: FCID persistent table is 
almost full 

Explanation    Fcdomain has 80% or more of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.

Recommended Action    Purge stale entries [purge fcdomain fcid] to obtain more free entries.

FCDOMAIN-5

Error Message     FCDOMAIN-5-DOMAIN_TYPE_IS_PREFERRED: The domain ID type is currently 
configured as preferred in all the existing VSANs 

Explanation    All the currently existing VSANs have the domain ID type configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link.

Recommended Action    Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.

Error Message     FCDOMAIN-5-FCIDP_DISABLED: FCID persistency feature is currently not 
enabled in any of the existing VSANs 

Explanation    All the currently existing VSANs have the FCID persistency feature disabled.

Recommended Action    Type [fcdomain fcid persistent vsan <vsan-id>] to enable FCID persistency in an existing VSAN. Type [fcdomain fcid persistent global-enable] to automatically enable the FCID persistency feature on all newly created VSANs.

Error Message     FCDOMAIN-5-FCID_PERSISTENT_TBL_HALF_FULL: FCID persistent table is 
half full 

Explanation    Fcdomain has 50% of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.

Recommended Action    You may want to purge stale entries [purge fcdomain fcid] to obtain more free entries.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSDATAREQUEST: Received CFS Data request 
from unknown domain [dec]. 

Explanation    A CFS Data request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSLOCKREQUEST: Received CFS Lock request 
from unknown domain [dec]. 

Explanation    A CFS Lock request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININCFSRELEASEREQUEST: Received CFS Release 
request from unknown domain [dec]. 

Explanation    A CFS Release request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

Error Message     FCDOMAIN-5-UNKNOWNDOMAININUNKNOWNCFSREQUEST: Received CFS request 
from unknown domain [dec]. 

Explanation    A CFS request from the unknown domain [dec] has been received.

Recommended Action    No action is required.

FCDOMAIN-6

Error Message     FCDOMAIN-6-BF_STARTED: BF started by [chars] 

Explanation    Build Fabric has been started in this VSAN

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-CANNOTFREESINGLEFCID: Impossible to free single FCIDs 

Explanation    Impossible to free single FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-CLEARLOCKNOTIFICATIONRECEIVED: Implict lock release. 

Explanation    Lock has been implicitly released due to a clear session operation.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOMAINID_INVALID: Local domain ID invalid 

Explanation    The local domain ID is invalid.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOMAINID_VALID: Local domain ID [dec] available 

Explanation    The domain ID [dec] is available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-DOWNSTREAM_SWITCHED: Downstream interface has been 
fast-switched from [chars] to [chars] 

Explanation    Because of a link failure the downstream interface has been fast-switched from [dec] to [dec].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_ALREADY_CREATED: Interface [chars] already created 

Explanation    Interface [chars] already created.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_ALREADY_DOWN: Interface [chars] is already down 

Explanation    Interface [chars] already down.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_CLEANUP: Interface [chars] received cleanup request 

Explanation    Fcdomain on interface [chars] has received a cleanup request.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_CREATED: Creation of interface [chars] 

Explanation    Fcdomain is going to create interface [chars].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-EPORT_DOWN: Interface [chars] is down 

Explanation    Fcdomain is going to remove interface [chars] from its database.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICCONFSTARTBF: Non disruptive reconfiguration started 

Explanation    A non disruptive reconfiguration (BF phase) of the VSAN has started. This can happen when two or more fabrics merge, or when the user manually triggers a non diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICNAME_INVALID: Fabric name not available 

Explanation    Fabric name not available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FABRICNAME_VALID: Fabric name [chars] available 

Explanation    Fabric name [chars] available.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDALREADYFREE: FCIDs already free 

Explanation    FCIDs already free.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDNOTSTORED: FCIDs not stored 

Explanation    FCIDs not stored.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDP_ENABLED_DOM_TYPE_PREFERRED: FCID persistency is 
enabled, but the domain ID type is configured as preferred 

Explanation    The FCID persistency feature is enabled, but the domain ID type is configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link. Should the domain ID change, all the FCIDs associated with it would be invalidated.

Recommended Action    Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.

Error Message     FCDOMAIN-6-FCIDS_ASSIGNED: Assigned a sequence of 256 contiguous 
FCIDs starting from FCID [hex]:[hex]:[hex] 

Explanation    Assigned a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCIDS_FREED: Freed a sequence of 256 contiguous FCIDs 
starting from FCID [hex]:[hex]:[hex] 

Explanation    Freed a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCID_ASSIGNED: Assigned single FCID [hex]:[hex]:[hex] 

Explanation    Assigned single FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-FCID_FREED: Freed single FCID [hex]:[hex]:[hex] 

Explanation    Freed single FCID [hex]:[hex]:[hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INCORRECTDOMAINRANGE: Requested FCIDs with domain field 
not in expected range 

Explanation    Requested FCIDs with domain field not in expected range.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INCORRECTDOMAIN: Requested FCIDs with domain field 
different from local domain 

Explanation    Requested FCIDs with domain field different from local domain.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-INVALIDARG: Requested FCID of type 00.00.YY, but 
specifying an entire area 

Explanation    Requested FCID of type 00.00.YY, but specifying an entire area.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-MY_SAME_WWN_DIFFERENT_DOMS_CONFLICTS: During VSAN merge 
detected local WWN [chars] is already in use by another switch (the two switches 
have different domain IDs: [dec] (local) and [dec]) 

Explanation    It has been detected that the local switch has the same WWN [chars] of another switch, and that they have different domain IDs: [dec] (local) and [dec].

Recommended Action    Check which switches have the same WWN and change either one.

Error Message     FCDOMAIN-6-NODOMAIN: Local domain not available 

Explanation    The local domain is not available yet.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-NOFREEFCID: No free FCIDs 

Explanation    No free FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-NOTOWNER: Feature [dec] cannot free FCID [dec]:[dec]:[dec] 
(feature [dec] is the actual owner) 

Explanation    Feature UUID [dec] cannot free FCID [dec]:[dec]:[dec] because it is not its owner (UUID actual owner is [dec]).

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-OTHER_SIDE_VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN 
merge detected overlap with virtual IVR domain ID [dec] from across the link 

Explanation    It has been detected an overlap with the virtual IVR domain ID [dec] from across the link during an attempt to merge the local VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-PSWSSTARTED: Principal Switch Selection started 

Explanation    Fcdomain started a principal switch selection phase to elect a principal switch in this VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-RCF_STARTED: RCF started by [chars] 

Explanation    Reconfigure Fabric has been started in this VSAN

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQSINGLEFCIDWITHINRESERVEDRANGE: Requested single FCIDs 
in area [dec] within the reserved range 

Explanation    Requested single FCIDs in area [dec] within the reserved range.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDFCIDNOTFREE: Requested FCIDs not free 

Explanation    Requested FCIDs not free.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDFCIDRESERVED: Requested reserved FCIDs 

Explanation    Requested reserved FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-REQUESTEDRESERVEDFCIDMISMATCH: Requested persistent 
FCIDs, but there is a mismatch 

Explanation    Requested persistent FCIDs, but there is a mismatch.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-SAME_WWNS_DIFFERENT_DOMS_CONFLICTS: During VSAN merge 
detected two switches with same WWN [chars] and different non-virtual domain IDs 
[dec] and [dec] 

Explanation    It has been detected that two switches have the same WWN [chars], but different non-virtual domain IDs: [dec] and [dec].

Recommended Action    Check which switches have the same WWN and change either one.

Error Message     FCDOMAIN-6-TIMER_UNKNOWN: fcdomain has received a notification for an 
unknown timer expiration

Explanation    A timer unknown to fcdomain has expired.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UPSTREAM_SWITCHED: Upstream interface has been 
fast-switched from [chars] to [chars] 

Explanation    Because of a link failure the upstream interface has been fast-switched from [dec] to [dec].

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UUIDNOSPACEFOUND: No available space to store the identity 
of the requestor the FCIDs 

Explanation    No available space to store the identity of the requestor the FCIDs.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-UUIDNOTFOUND: Universal Unique ID (UUID) not found 

Explanation    Universal Unique ID (UUID) not found.

Recommended Action    No action is required.

Error Message     FCDOMAIN-6-VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN merge detected 
overlap with local virtual IVR domain ID [dec] 

Explanation    It has been detected an overlap with the local virtual IVR domain ID [dec] during an attempt to merge the local VSAN.

Recommended Action    No action is required

FCDOMAIN-7

Error Message     FCDOMAIN-7-EPORT_ALREADY_ISOLATED: Interface [chars] is already 
isolated or down 

Explanation    Fcdomain was going to isolate interface [chars], but the interface is already isolated.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FABRICCONFCOMPLETEDBF: Non disruptive reconfiguration 
completed 

Explanation    A non disruptive reconfiguration (BF phase) completed. This can happen when two or more fabrics merged, or when the user manually triggered a non diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FABRICCONFCOMPLETEDRCF: Disruptive reconfiguration 
completed 

Explanation    A disruptive reconfiguration (RCF phase) of the VSAN has completed. This can happen when two or more fabrics merged disruptively, or when the user manually triggered a diruptive reconfiguration of the VSAN.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FC2_RETRY: Retransmission of FC2 frame on interface 
[chars] (Cmd Code: [hex]) 

Explanation    Fcdomain is retrying an FC2 frame on interface [chars] due to loss/no response. The Command Code of the frame is [hex].

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FCID_IN_USE_PURGING_FOR_FICON_MGR: FICON needs to purge 
the persistent FCID table, but at least one FCID is still in use, preventing this 
purge from completely remove all entries belonging to the VSAN.

Explanation    There may be a problem in the sequence that shuts down all interfaces before fcdomain receives a request from FICON Manager to purge the persistent FCID table.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FSM_FAILED: FSM transition failed on interface [chars] 
(current state [chars]) 

Explanation    Fcdomain state machine generated an invalid event on interface [chars], for which no proper action was defined (current state [chars].)

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-FSM_FORBIDDEN_TRANSITION: fcdomain state machine has hit 
a forbidden transition 

Explanation    Fcdomain state machine has tried to execute a forbidden transition.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-INTERFACERDY: Interface [chars] ready 

Explanation    Interface [chars] is ready.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-PREACTIONTYPE_UNKNOWN: fcdomain state machine has hit an 
unknown pre-action type 

Explanation    An undefined pre-action type has been used.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-PSWSCOMPLETED: Principal Switch Selection completed 

Explanation    A Principal Switch Selection (PSwS phase) completed.

Recommended Action    No action is required.

Error Message     FCDOMAIN-7-RDIACC: Assigned domain ID [dec], WWN of requestor [chars] 
(requested domain ID [dec]) 

Explanation    Domain ID [dec] has been received by VSAN with WWN [chars] (requested domain ID was [dec].)

Recommended Action    No action is required.

Error Message     FCD-7-SB3_ABTS_EXCHANGE: sb3 aborted exchange [hex] from vsan:[dec] 
ch:[hex] chi:[hex] ccw:[hex] token:[hex] cmd:[hex] reason:[chars] 
state:[chars]:[dec] 

Explanation    SB3 aborted exchange due to reason given. Aborts are caused by either the channel or control unit detecting a device protocol error. Recovery actions are performed to restore communication. In certain circumstances aborts occur in normal operations.

Recommended Action    No action is required if communication with CUP device is still operational.

Error Message     FCD-7-SB3_UCS_PER_FILE_FN: VSAN:[dec] Unit Check for perform file 
function, reason: [chars] 

Explanation    SB3 failed perform file function. Failure is caused by error in the file main frame sent to director.

Recommended Action    No action is required if communication with CUP device is still operational.

FCFWD Messages

This section contains the FCFWD messages.

FCFWD-3

Error Message    FCFWD-3-ERROR: [chars] 

Explanation    Fcfwd encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FCFWD-4

Error Message     FCFWD-4-WARNING: [chars] 

Explanation    Fcfwd is generating a relevant notification

No action is required.

Error Message    FCFWD-6
Error Message     FCFWD-6-INFO: [chars] 

Explanation    An fcfwd event occurred

Recommended Action    No action is required.

FCNS Messages

This section contains the FCNS messages.

FCNS-2

Error Message    FCNS-2-DB_FULL: the database; max entries [dec] exceeded 

Explanation    Name server database is full. The max number of entries, [dec], of ports is already present in the database

Recommended Action    No action is required.

Error Message     FCNS-2-INIT_FAILURE: : [chars] 

Explanation    Fcns initialisation has failed due to [chars].

Recommended Action    No action is required.

Error Message     FCNS-2-NO_RESPONSE: for query [chars] from domain [dec] 

Explanation    No response for query [chars] from domain [dec].

Recommended Action    No action is required.

Error Message     FCNS-2-PSS_VERSION_MISMATCH: : for [chars] 

Explanation    Version mismatch for pss of type [chars].

Recommended Action    No action is required.

Error Message     FCNS-2-RELOAD_FAILURE: : [chars] 

Explanation    Failed to reload information from PSS: [chars].

Recommended Action    No action is required.

FCNS-3

Error Message     FCNS-3-BAD_FRAME: : [chars] 

Explanation    Received a bad frame from the network: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-CFG_FAILURE: : [chars] 

Explanation    A failure related to fcns configuration: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-CHUNK_FAILURE: : [chars] 

Explanation    Chunk memory failure: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-DB_FAILURE: : [chars] 

Explanation    A failure occured in fcns database: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-MALLOC_FAILURE: : [chars] 

Explanation    Malloc failed: [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-MTS_FAILURE: : [chars] [chars] 

Explanation    Failure occured trying to do an MTS operation: [chars] [chars].

Recommended Action    No action is required.

Error Message     FCNS-3-PSS_FAILURE: : [chars] 

Explanation    Pss failure: [chars].

Recommended Action    No action is required.

FCNS-4

Error Message     FCNS-4-QUERY_NO_RESPONSE: for query [chars] from domain [dec] 

Explanation    No response for query [chars] from domain [dec].

Recommended Action    No action is required.

FCNS-6

Error Message     FCNS-6-DB_INFO: : [chars] [hex] 

Explanation    Database modification:[chars] for entry [hex].

Recommended Action    No action is required.

Error Message     FCNS-6-STATUS_INFO: : [chars] 

Explanation    A change in fcns status: [chars].

Recommended Action    No action is required.

FCSP-MGR Messages

This section contains the FCSP-MGR messages.

FCSP-MGR-2

Error Message    FCSP-MGR-2-DBG_INIT_FAILED: Debug Infrastructure Initialization 
failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an 
E_Port failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the FC-2 E-Port infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an 
F_Port failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the FC-2 F-Port infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown 
FC-2 frame on [chars] 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FCSP_AUTHENT_FAILURE: FC-SP Authentication failure on Port 
[chars] (FC-SP Failure Reason: [chars] [chars]) 

Explanation    Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FCSP_ESP_MISMATCH: ESP parameters mismatch failure on Port 
[chars] (reason:[chars]) 

Explanation    Fibre-Channel ESP parameters mismatch with the peer on Port [chars].(Reason: [chars]). Please check ESP configurations on both side of the link and ensure appropriate ESP mode on this port as well as peer port

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-FSMU_INIT_FAILED: State Machine Infrastructure 
Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-IPC_INIT_FAILED: IPC (Inter Process Communication) 
Initialization failed ( [chars] ) 

Explanation    FC-SP Manager has been unable to initialize with the IPC infrastructure.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service 
exiting 

Explanation    License of [chars] is unavailable. Service will exit now

Recommended Action    Please install the license file to continue using the feature.

Error Message     FCSP-MGR-2-MEM_FAILED: Memory operations failed File: [chars] Line 
[dec] for size [hex] bytes 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-POST_INIT_FAILED: Post-Initialization failed ( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

Error Message     FCSP-MGR-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed 
( [chars] ) 

Explanation    The system has detected an error.

Recommended Action    No action is required.

FCS Messages

This section contains the FCS messages.

FCS-2

Error Message    FCS-2-ALLOC_FAILED: Memory allocation failed for size:[dec] 

Explanation    Memory allocation failed for size [dec]

Recommended Action    Restart the process

Error Message     FCS-2-CHUNK_ALLOC_FAILED: Chunk memory allocation failed for [chars] 
chunk 

Explanation    Chunk memory allocation failed. [chars] indicates the chunk name

Recommended Action    Restart the process

Error Message     FCS-2-NO_RESPONSE: Retried maximum number of times for [chars] to 
domain [dec] in VSAN [dec] 

Explanation    Maximum number of retires completed for [chars] form domain [dec] in VSAN [dec].

Recommended Action    No action is required.

Error Message     FCS-2-PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], 
expected version [dec].[dec].[dec] 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-2-RANDNUM_FAIL: [chars] 

Explanation    There was a critical error during random number generation. [chars] indicates details of the error

Recommended Action    No action is required.

FCS-3

Error Message     FCS-3-DB_ERR: [chars] 

Explanation    An error occurred during an FCS database operation. [chars] indicates the reason for the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-INIT_FAIL: [chars] 

Explanation    An error happened during FCS Initialization. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-MTS_ERR: [chars] 

Explanation    An error occurred in processing of an MTS message. [chars] indicates the error that occurred

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-NO_MTS_RESP: [chars] 

Explanation    There was no response to an MTS request. [chars] indicates details of the MTS message

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-NO_REMOTE_RESP: No response for request [chars] from domain 
[dec] in VSAN [dec] 

Explanation    There was no response to an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-OTHER_ERR: [chars] 

Explanation    An FCS generic error occurred. [chars] indicates the description of the error

Recommended Action    No action is required.

Error Message     FCS-3-PSS_ERR: [chars] 

Explanation    An error occurred during an FCS PSS operation. [chars] indicates the PSS operation that caused the error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FCS-3-SOCK_ERR: sd: [dec], [chars] 

Explanation    An FC-2 Socket error occurred on socket-ID [dec]. [chars] indicates the reason for failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FCS-4

Error Message     FCS-4-BAD_CT_FRAME: Invalid FCS frame: [chars] received from [hex] 

Explanation    An invalid FCS FC-CT frame with [chars] received from FC-ID [hex].

Recommended Action    No action is required.

FCS-5

Error Message     FCS-5-API_FAIL: [chars]: [chars] 

Explanation    An API called by FCS failed. [chars] indicates the API name failed and [chars] the reason for failure

Recommended Action    If this message is seen during a cold boot, it means that the queried module came up after FCS and this case can be ignored

Error Message     FCS-5-DB_NOTICE: [chars] 

Explanation    An error occurred during an FCS database operation. [chars] indicates the reason for the error

Recommended Action    No action is required.

FCS-6

Error Message     FCS-6-INFORMATION: [chars] 

Explanation    An event happend that affects FCS. [chars] indicates the event

Recommended Action    No action is required.

Error Message     FCS-6-REXMIT_PKT: Retransmitting request [chars] to domain [dec] in 
VSAN [dec] 

Explanation    There was a retransmission of an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID

Recommended Action    No action is required.

FDMI Messages

This section contains the FDMI messages.

FDMI-2

Error Message    FDMI-2-MTS_ERROR: MTS message transmission failed with error [dec] 

Explanation    Fdmi process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]

Recommended Action    No action is required.

Error Message     FDMI-2-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] 
failed with error [hex] for key type [dec]

Explanation    Fdmi read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code

Recommended Action    No action is required.

Error Message     FDMI-2-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    Fdmi read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system err code

Recommended Action    No action is required.

FDMI-3

Error Message     FDMI-3-BAD_FRAME: Malformed frame received: [chars] 

Explanation    Fdmi process received malformed frame. [chars] describes the malformation

Recommended Action    No action is required.

Error Message     FDMI-3-BAD_RESPONSE: response with command code: [hex] 

Explanation    Fdmi process received bad payload in response

Recommended Action    No action is required.

Error Message     FDMI-3-INTERNAL_ERROR: Internal err: [chars] 

Explanation    Fdmi process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     FDMI-3-MTS_API_ERROR: API, [chars] returned [hex] 

Explanation    Fdmi invoked API [chars], received the error code specified in 0x[hex]

Recommended Action    No action is required.

Error Message     FDMI-3-MTS_FORMAT_ERROR: Unknown MTS message format in opcode [dec] 
from module [chars] 

Explanation    Fdmi received message from module [chars] which contains unknown message format. MTS opcode is specified in [dec]

Recommended Action    No action is required.

Error Message     FDMI-3-NO_RESPONSE: No response from switch whose domain id is [dec] 

Explanation    Fdmi process sents a inter-switch packets to switches and has not received the response

Recommended Action    No action is required.

Error Message     FDMI-3-PSS_ERROR: PSS operation [chars] returned err: [hex] 

Explanation    [chars] specifies the context where the failure occured and 0x[hex] specifies the err

Recommended Action    No action is required.

Error Message     FDMI-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is 
received 

Explanation    Fdmi process received unexpected MTS event. MTS opcode is specified in [dec]

Recommended Action    No action is required.

FDMI-4

Error Message     FDMI-4-SW_REJ_RESPONSE: Reject response [chars] from switch whose 
domain id is [dec] 

Explanation    Fdmi process sents a inter-switch packets to switches and has received the reject response with reason code in [chars]

Recommended Action    No action is required.

FDMI-6

Error Message     FDMI-6-DEBUG_INFO: [chars] 

Explanation    Fdmi process debug info

Recommended Action    No action is required.

FEATURE-MGR Messages

This section contains the FEATURE-MGR messages.

FEATURE-MGR-2

Error Message    FEATURE-MGR-2-MODULE_FM_DONE: feature manager completed 

Explanation    Feature manager completed

Recommended Action    No action is required.

Error Message     FEATURE-MGR-2-MODULE_FM_STARTED: feature manager started 

Explanation    Feature manager started

Recommended Action    No action is required.

FICON Messages

This section contains the FICON messages.

FICON-2

Error Message    FICON-2-E_DUPLICATE_PN_BRINGUP_FAIL: [chars] 

Explanation    This port has the same port number assigned to other port in the same FICON VSAN. No more than one port with duplicate port number can be up in each FICON VSAN

Recommended Action    Avoid duplicate number assignment in each FICON VSAN\n

Error Message     FICON-2-E_PN_PA_NOT_IN_BOUND: [chars] 

Explanation    Port number or port address in startup-configure is out of bound.

Recommended Action    Change ficon port number assign configuration and save to startup-configure.\n

Error Message     FICON-2-E_SAVE_FILE: [chars] 

Explanation    Failed to save file. Possibly due to asymmetric pdcm matrix. Look for retval for actual reason.

Recommended Action    Configure port prohibits in symmetrically.\n

Error Message     FICON-2-SHUTDOWN: FICON Manager process shutting down: [chars] 

Explanation    FICON Manager shutting down

Recommended Action    This is a severe error. Provide the reason given in the message\n

FICON-3

Error Message     FICON-3-E_ASSIGN_BINDING_PN_FAIL: [chars] 

Explanation    Port number has fcip or port channle binding can not be removed nor changed.

Recommended Action    Remove port number binding of the logical interface first.\n

Error Message     FICON-3-E_ASSIGN_INVALID_PN_PARAM: [chars] 

Explanation    Invalid port number parameters in command.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_ASSIGN_OVERLAP_PN_FAIL: [chars] 

Explanation    Port number assigned to physical and logical can not overlap.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_ASSIGN_PN_NOT_DOWN_FAIL: [chars] 

Explanation    Only port number assigned to a port in down state can be removed or changed.

Recommended Action    Bring down the port first.\n

Error Message     FICON-3-E_ASSIGN_PROHIBIT_PN_FAIL: [chars] 

Explanation    Logical port address can not be prohibited.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-E_DUPLICATE_PN_ASSIGN_WARNING: [chars] 

Explanation    This port has the same port number assigned to other port in the same FICON VSAN. No more than one port should have the same port number in each FICON VSAN

Recommended Action    Avoid duplicate number assignment in each FICON VSAN\n

Error Message     FICON-3-E_INVALID_PA_BRINGUP_FAIL: [chars] 

Explanation    This port either has an invalid port address assigned or has no port address assigned.

Recommended Action    Assign a valid ficon port number to the port.\n

Error Message     FICON-3-E_PORT_PROHIBIT_BRINGUP_FAIL: [chars] 

Explanation    This port has been prohibited. Prohibiting E or TE ports is not allowed. This port can not be configured in E mode or TE mode until the prohibit mask configuration is changed

Recommended Action    Correct the prohibit mask (PDCM) for this port if you wish to bring it up as an E or TE port in a FICON VSAN\n

Error Message     FICON-3-E_UNASSIGN_NO_PN_FAIL: [chars] 

Explanation    Only port number already assigned can be removed.

Recommended Action    Check port numbers in the command.\n

Error Message     FICON-3-PDCM_CHANGE_REJ_E_PORT: [chars] 

Explanation    The FICON Prohibit Dynamic Connectivity Mask(PDCM) change rejected because an E or TE port is being prohibited. Prohibiting an E or TE port in not allowed

Recommended Action    Correct the prohibit mask (PDCM) for this port if you wish to bring the port up as an E or TE port in a FICON VSAN\n

FICON-5

Error Message     FICON-5-STARTING: FICON Manager process starting 

Explanation    FICON Manager process is being started

Recommended Action    No action is required.

FICON-6

Error Message     FICON-6-PDCM_CHANGE: VSAN [dec] port-address [dec] prohibit mask set 
to [chars] 

Explanation    The FICON Prohibit Dynamic Connectivity Mask (PDCM) for this port has changed. VSAN [dec], port address [dec] prohibit mask (PDCM) is now set to [chars]

Recommended Action    No action is required.

Error Message     FICON-6-PORT_SWAP: port number [dec] [dec] swapped 

Explanation    FICON portnumbers swapped

Recommended Action    No action is required.

Error Message     FICON-6-VSAN_DISABLED: FICON disabled on VSAN [dec] 

Explanation    FICON has been disabled on the given VSAN

Recommended Action    No action is required.

Error Message     FICON-6-VSAN_ENABLED: FICON enabled on VSAN [dec] 

Explanation    FICON has been enabled on the given VSAN

Recommended Action    No action is required.

FLOGI Messages

This section contains the FLOGI messages.

FLOGI-1

Error Message    FLOGI-1-MSG_FDISC_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface 
[chars]] FDISC rejected - this interface has reached the max num of N-Ports ([dec]) 

Explanation    An FDISC was rejected because the F-Port has reached the maximum allowed number of devices.

Recommended Action    Check the configuration of the NPIV device connected to the port.

Error Message     FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: [VSAN [dec], Interface [chars]] 
FLOGI rejected - FCID allocation failed. 

Explanation    An FLOGI was rejected because the FCID allocation failed.

Recommended Action    Check the fcid-interop configuration, purge the persistency table and check the output of show flogi database details and see if any of the A area FCID allocation entries can be turned to single fcid allocation as per Configuration Guide

Error Message     FLOGI-1-MSG_FLOGI_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface 
[chars]] FLOGI rejected - this interface has reached the max num of NL-Ports 
([dec]) 

Explanation    An FLOGI was rejected because the FL-Port has reached the maximum allowed number of devices.

Recommended Action    Reduce the number of devices on the loop

Error Message     FLOGI-1-MSG_NPIV_NOT_SUPPORTED_WITH_TRUNKING: [VSAN [dec], Interface 
[chars]] NPIV not supported - on this platform, NPIV is not supported on trunking 
interfaces 

Explanation    The N_Port requested NPIV, but this platform does not support NPIV on trunking F_Ports.

Recommended Action    Disable NPIV, or move the N_Port to a switch that supports NPIV on trunking F_Ports

FLOGI-2

Error Message     FLOGI-2-MSG_FLOGI_REJECT_NO_ACL_TCAM_AVAILABLE: [VSAN [dec], 
Interface [chars]] FLOGI rejected - ACLTCAM resource exausted 

Explanation    An FLOGI was rejected because the ACLTCAM hardware resource is completely used.

Recommended Action    Reduce the number of nodes.

FLOGI-4

Error Message     FLOGI-4-MSG_VF_FLOGI_FROM_NON_CISCO_OUI: [VSAN [dec], Interface 
[chars]] FLOGI with VF bit set from OUI [hex]:[hex]:[hex] (nwwn: [chars]) 

Explanation    This interface received an FLOGI with VF bit set from a non CISCO OUI; in this release Virtual Fabrics are not supported on interfaces connected to third-party devices

Recommended Action    Set the trunk mode of this interface to off

FLOGI-5

Error Message     FLOGI-5-MSG_FLOGI_DROP_DUE_TO_SUSPENDED_VSAN: [VSAN [dec], Interface 
[chars]] FLOGI (pwwn: [chars]) has been dropped because the VSAN is suspended on 
this trunking interface 

Explanation    The switch received an FLOGI from a trunking interface on a VSAN which has been suspended; the FLOGI frame has been dropped.

Recommended Action    To bring up the VSAN again on the trunking port, remove it from the allowed VSAN list and add it again

Error Message     FLOGI-5-MSG_IF_REINIT_ALPA_CONFLICT: [VSAN [dec], Interface [chars]] 
FL/TL interface [chars] re-initialized as ALPA - PWWN map conflict occurred. 

Explanation    The FL/TL interface is re-initialized as ALPA used by device conflicts with an existing FLOGI session after the Loop Initialization Protocol (LIP). All the devices will re-login with new ALPA and PWWN mapping

Recommended Action    No action is required.

Error Message     FLOGI-5-MSG_PORT_LOGGED_IN: [VSAN [dec], Interface [chars]] Nx Port 
[chars] with FCID [chars] logged IN. 

Explanation    Nx port logged in with the specified information.

Recommended Action    No action is required.

Error Message     FLOGI-5-MSG_PORT_LOGGED_OUT: [VSAN [dec], Interface [chars]] Nx Port 
[chars] logged OUT. 

Explanation    Nx port logged out. The following commands will help determine why this Nx port logged out: 'show interface, show VSAN, show module'

Recommended Action    No action is required.

FS-DAEMON Messages

This section contains the FS-DAEMON messages.

FS-DAEMON-2

Error Message    FS-DAEMON-2-FSD_ENOSPC_BOOTFLASH: Due to insufficient space, [chars] 
image could not be copied to standby bootflash. [chars] image is not present on 
standby. Please copy \[chars]\'manually.'

Explanation    Move system images from RAM to bootflash to free up some memory

Recommended Action    Please remove some unnecessary files on bootflash using \delete\'CLIcommandandcopyimagesfromactivesupervisororfromremotelocation'

FS-DAEMON-6

Error Message     FS-DAEMON-6-FSD_ENOSPC_LOGFLASH: System logflash usage has reached 
[dec]%. You may delete some old files on logflash to free up space 

Explanation    System logflash space is almost full

Recommended Action    Use 'clear core archived' or 'delete' CLI to free up space on logflash

Error Message     FS-DAEMON-6-FSD_ENOSPC_ROOT: System root usage has reached [dec]%. 
You may delete some old files from root or /var/log to free up space 

Explanation    System root space is almost full

Recommended Action    Use 'clear core archived' or 'delete' CLI to free up space on root dir or /var/log

Error Message     FS-DAEMON-6-FSD_ENOSPC_TMP: System temporary directory usage has 
reached [dec]%. 

Explanation    System /tmp space usage.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FSCM Messages

This section contains the FSCM messages.

FSCM-2

Error Message    FSCM-2-FABRIC_START_CFG_MGR_PROGRAM_EXIT: Fabric Start Cfg Mgr daemon 
exiting: [chars] 

Explanation    FABRIC_START_CFG_MGR daemon is exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FSPF Messages

This section contains the FSPF messages.

FSPF-2

Error Message    FSPF-2-SHUTDOWN: Routing daemon shutting down : [chars] 

Explanation    FSPF routing daemon is shutting down because of [chars] reason.

Recommended Action    This is a severe bug. Provide the reason provided and the log files for FSPF.

FSPF-3

Error Message     FSPF-3-BAD_FC2_PKT: Received bad FC2 packet on interface [chars] : 
[chars] 

Explanation    FSPF received a bad FC2 packet on [chars] interface , error description is [chars].

Recommended Action    FSPF daemon has received a bad FC frame. Provide the output of 'debug fc2 pkt '.

Error Message     FSPF-3-CHECKSUM_FAIL: Checksum test failed for LSR domain [dec] 

Explanation    Periodic database checksum test failed for LSR for domain [dec]

Recommended Action    This indicates that the internal database got corrupted because of some memory corruption bug. Provide output of 'show fspf database '. May need to power cycle the switch

Error Message     FSPF-3-FC2_PROC_ERR: Error in processing [chars] packet on interface 
[chars], Error = [chars] 

Explanation    An error occurred in processing a [chars] FC2 packet on [chars] interface. The internal error code is [chars].

Recommended Action    Turn on 'debug fspf error' to get more information. Make sure there is no misconfiguration of FSPF parameters on the two ends of the interface. Provide output of 'show fspf vsan x' 'show fspf vsan x interface' and 'debug fspf fc pkt ' for the specific interface

Error Message     FSPF-3-FLOOD_ERR: Error in flooding the local LSR , Error = [chars] 

Explanation    FSPF had an error in flooding the local LSR , error description is [chars].

Recommended Action    Provide output of 'debug fspf flood' , 'debug fspf error'. If error is reported in transmitting packet check if interface is up and turn on 'debug fc2 error'

Error Message     FSPF-3-HELLO_MISMATCH: Mismatch in [chars] in the Hello packet on 
interface [chars] 

Explanation    There is a mismatch in the [chars] entry in the hello packet received on interface [chars]. The packet will be dropped.

Recommended Action    Check the configuration of hello or dead interval on the switches on the two ends of the interface to see if there is a mismatch.

Error Message     FSPF-3-INTF_TIMER_ERR: Error in processing interface timer event 
[chars] for interface [chars] , error = [chars] 

Explanation    FSPF had an error in processing timer event for interface chars, error is [chars].

Recommended Action    Provide output of 'debug fspf error'

Error Message     FSPF-3-IPC_PROC_ERR: Error in processing IPC message : Opcode = [dec], 
Error code = [hex] 

Explanation    FSPF had an error in processing message of [dec] opcode , the internal error code is [dec].

Recommended Action    Possibly some wrong IPC message is received by FSPF . Provide output of 'debug fspf mts pkt' and 'debug fspf error ' trace.

Error Message     FSPF-3-LOCK_FAIL: FSPF failure in gaining lock 

Explanation    There is a software failure in gaining lock of the shared resource between FSPF threads.

Recommended Action    Provide output of 'debug fspf all '

Error Message     FSPF-3-MTS_MSG_BEFORE_GSYNC: FSPF in standby received MTS message 
opcode = [hex] before GSYNC 

Explanation    FSPF in standby received an MTS message of opcode [dec] before receiving the GSYNC message.

Recommended Action    Provide output of 'debug fspf mts pkt '

Error Message     FSPF-3-RIB_ERR: Error in RIB : [chars] 

Explanation    FSPF had an error in interacting with RIB, error description is [chars].

Recommended Action    Check if rib application is running using 'show processes'. Provide output of 'debug fspf route' and RIB debug traces.

Error Message     FSPF-3-ROUTE_COMPUTE_ERR: Error in computing or sending routes : Error 
= [chars] 

Explanation    FSPF had an error in computing routes , error description is [chars].

Recommended Action    Provide the error code and output of 'debug fspf error' and 'debug fspf route' if problem is reproducible

Error Message     FSPF-3-UNLOCK_FAIL: FSPF failure in releasing lock 

Explanation    There is a software failure in releasing lock of the shared resource between FSPF threads.

Recommended Action    Provide output of 'debug fspf all '

Error Message     FSPF-3-VSAN_TIMER_ERR: Error in processing VSAN timer event [chars], 
error description = [chars] 

Explanation    FSPF had an internal error in processing timer event , error description is [chars].

Recommended Action    Provide output of 'debug fspf error'

FSPF-4

Error Message     FSPF-4-FC2_DOWN_INTF: Received FC2 packet on DOWN interface [chars] 

Explanation    FSPF received a FC2 packet on inactive interface [chars] .

Recommended Action    This message may be printed for the first FSPF packet when an interface is brought up. If the message is seen continuously check if FSPF is disabled on one end for the interface or the VSAN. Otherwise check 'show interface ' output to see if interface is physically up only on one side. Also check if there is any error message printed for IPC_PROC_ERR

Error Message     FSPF-4-FC2_DOWN_VSAN: Received FC2 packet on inactive vsan 

Explanation    FSPF received a FC2 packet on inactive vsan.

Recommended Action    If message seen continuously check if FSPF is disabled on the VSAN Investigate if VSAN is active and valid domain has been assigned on the switch Also check if IPC_PROC_ERR message is printed in the syslog

Error Message     FSPF-4-ILLEGAL_FSM_EVENT: Illegal FSM event for state [chars] in 
interface [chars] 

Explanation    An illegal protocol event has occurred for the FSPF state machine. The old state was [chars] for the interface [chars].

Recommended Action    It is possible to get this message if some protocol packet gets dropped but the it should recover and move back to FULL state. Do 'show fspf interface' to check the state of the interface. If it is stuck in state other than FULL provide output of 'debug fspf event' and 'debug fspf fc pkt ' for the interfaces involved.

Error Message     FSPF-4-LSR_DROPPED: [chars], Dropping LSR [dec] received on interface 
[chars] 

Explanation    A LSR packet is dropped due to [chars] reason. LSR belonged to domain [dec] and was received on interface [chars].

Recommended Action    Provide the reason given for dropping the LSR and output of 'debug fspf fc pkt' If the reason is checksum failure investigate possible packet corruption or truncation

Error Message     FSPF-4-LSR_MIN_LS_ARRIVAL: Packet arrived before MIN_LS_ARRIVAL, 
Dropping LSR [dec] on interface [chars] 

Explanation    A LSR packet is dropped as it arrived before MIN_LS_ARRIVAL. LSR belonged to domain [dec] and was received on interface [chars].

Recommended Action    This can occur in transient situation and protocol recovers by retransmitting the LSR. If the message is seen continuously provide output of 'debug fspf flood ' , 'debug fspf retrans' and 'debug fspf error '. The message may be seen more often when interoperating with other vendors

Error Message     FSPF-4-LSU_RX_INIT: Dropping LSU received in state INIT on interface 
[chars] 

Explanation    A LSU packet is dropped as interface [char] is in INIT state when it received the LSU.

Recommended Action    This can occur in some transient situation. If the problem persists provide output of 'show fspf vsan x interface' and 'debug fspf fc pkt ' and 'debug fspf event vsan x'

FSPF-5

Error Message     FSPF-5-STARTING: Routing daemon started 

Explanation    FSPF routing daemon has been started.

Recommended Action    No action is required.

FSPF-6

Error Message     FSPF-6-ADD_LSR: New LSR added for domain [dec] 

Explanation    A new LSR is added to the database for domain [dec] .

Recommended Action    No action is required.

Error Message     FSPF-6-DELETE_LSR: LSR deleted for domain [dec] 

Explanation    The LSR for domain [dec] is deleted from the database.

Recommended Action    No action is required.

Error Message     FSPF-6-INTF_OPER_DOWN: Down on interface [chars] 

Explanation    FSPF has become operationally down on interface [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-INTF_OPER_UP: Up on interface [chars] 

Explanation    FSPF has become operational on interface [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-MAX_AGE: LSR [dec] reached Maxage 

Explanation    The LSR for domain [dec] reached the maximum age and will be deleted from all the connected switches .

Recommended Action    No action is required.

Error Message     FSPF-6-ROLLOVER: Rolling over the incarnation number of Local LSR 

Explanation    The incarnation number of local LSR reached the maximum value and is rolling over.

Recommended Action    No action is required.

Error Message     FSPF-6-SELF_ORIGINATED: Received local LSR with higher incarnation 
number 

Explanation    A LSR for the local domain was received with incarnation number higher than the one in database. This situation should only occur initially on a topology change. If this situation persists the domain assignment of switches may not be unique

Recommended Action    If this message is received continuously check if domain assignment is unique in the fabric.

Error Message     FSPF-6-STATE_CREATED: Internal state created [chars] 

Explanation    FSPF has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     FSPF-6-VSAN_OPER_DOWN: Down on vsan 

Explanation    FSPF has become operationally down on VSAN.

Recommended Action    No action is required.

Error Message     FSPF-6-VSAN_OPER_UP: Up with local domain [dec] 

Explanation    FSPF has started with local domain [dec].

Recommended Action    No action is required.

FSPF-7

Error Message     FSPF-7-ROUTE_THREAD_STARTED: Thread number [dec] started 

Explanation    Route computation thread number [dec] has been started for FSPF.

Recommended Action    No action is required.

FWM Messages

This section contains the FWM messages.

FWM-0

Error Message    FWM-0-FCFIB_EMERG: [chars] 

Explanation    Fcfib caused a system failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-1

Error Message     FWM-1-FCFIB_ALERT: [chars] 

Explanation    Fcfib caused failures in other services

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-1-FCFIB_HW_NO_VSAN_DOM: No hardware [chars] resources for route 
creation to VSAN [dec] Domain [dec] 

Explanation    Hardware does not have sufficient resources to create this route.

Recommended Action    Please delete unused VSANs or assign common Domain numbers to existing VSANs.

Error Message     FWM-1-FCFIB_HW_NO_VSAN: No hardware [chars] resources for route 
creation to VSAN [dec] 

Explanation    Hardware does not have sufficient resources to create this route.

Recommended Action    Please delete unused VSANs.

Error Message     FWM-1-FCFIB_HW_PC_LIMIT: Failed to create [chars], hardware limit of 
[dec] would be exceeded 

Explanation    The number of hardware SAN Port Channels is limited by the platform.

Recommended Action    Please configure fewer SAN Port Channels.

Error Message     FWM-1-FCFIB_LICENSE_UNAVAILABLE: License: [chars] is not installed. 
System will not provide FC switching. 

Explanation    Fibre Channel license is unavailable. System will not provide FC switching.

Recommended Action    Please install the license file to continue using the feature.

FWM-2

Error Message     FWM-2-FCFIB_CRIT: [chars] 

Explanation    Fcfib encountered a catastrophic error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-FWM_ASSERT_FAILURE: stack [[chars]] 

Explanation    Critical assertion failed in forwarding manager

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-FWM_CONFIG_ERROR: Wrong configuration. Ignoring configuration. 

Explanation    Configuration specified by the user is wrong. Configuration will be ignored.

Recommended Action    No action is required.

Error Message     FWM-2-FWM_OIFL_MCAST_IDX_LIMIT_REACHED: [chars] 

Explanation    The number of of multicast indices in the system have been exhausted. Cannot learn any more new multicast groups or create new vlans.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_LEARNING_RE_ENABLE: Re enabling dynamic learning on all 
interfaces 

Explanation    Re enabling learning on all interfaces after disable period expired

Recommended Action    No action is required.

Error Message     FWM-2-STM_LIMIT_REACHED: [chars] 

Explanation    System station table reached its capacity - no further MAC addresses could be programmed - administration intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_LOOP_DETECT: [chars] 

Explanation    System detected loops in the network - administration intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-2-STM_MCAST_PROG_RE_ENABLE: Re enabling programming multicast 
entries 

Explanation    Re enabling programming new multicast entries because number of entries reached below threshold

Recommended Action    No action is required.

Error Message     FWM-2-STM_RAPID_MOVES: [chars] 

Explanation    System detected rapid mac moves in the network - administrator intervention may be required to avoid this problem in future

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-3

Error Message     FWM-3-FCFIB_ERR: [chars] 

Explanation    Fcfib encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     FWM-3-FCFIB_NO_MEM: Out of memory 

Explanation    Fcfib does not have enough memory to continue proper operation.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-4

Error Message     FWM-4-FCFIB_CPU_HOG: Inactive or busy 

Explanation    Either fcfib was not scheduled to run, or fcfib was busy, and fcfib did not service the message or timer queue for an extended period.

Recommended Action    Please perform 'debug fwm error', then recreate the operation scenario, to find out more details.

Error Message     FWM-4-FWM_DUPLICATE_UNICAST_MAC_REGISTRATION: Unicast MAC address 
[chars] vlan [dec] registered on interface [chars] before deregistering on 
interface [chars]

Explanation    Duplicat unicast MAC registration observed

Recommended Action    No action is required.

Error Message     FWM-4-STM_LEARNING_OVERLOAD: [chars] 

Explanation    System getting overloaded due to learning processes

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

FWM-6

Error Message     FWM-6-MAC_MOVE_NOTIFICATION: Host [chars] in vlan [dec] is flapping 
between port [chars] and port [chars] 

Explanation    Notification of a MAC address moving as per configuration

Recommended Action    No action is required.

Error Message     FWM-6-STM_THRESHOLD_NOTIFICATION: Station table reached [dec]% of the 
total capacity (total entries [dec]) 

Explanation    Station table capacity utilization message as per configured threshold values

Recommended Action    No action is required.

GLBP Messages

This section contains the GLBP messages.

GLBP-2

Error Message    GLBP-2-GLBP_URIB_INIT_ERROR: [chars] 

Explanation    Unicast routing initialization failed and the GLBP process terminated

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

GLBP-3

Error Message     GLBP-3-GLBP_ARP_ADD_FAILED: failed to add [chars]/[chars] in arp 
table 

Explanation    The system was unable to add the GLBP vIP into the arp table

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

Error Message     GLBP-3-GLBP_ARP_DEL_FAILED: failed to delete [chars]/[chars] in arp 
table 

Explanation    The system was unable to delete the GLBP vIP from the arp table

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

Error Message     GLBP-3-GLBP_FEATURE_MANAGER_ERROR: [chars]: [chars] 

Explanation    There was a problem in GLBP interaction with feature manager.

Recommended Action    Please check the reason for error using feature manager and rectify the problem

Error Message     GLBP-3-GLBP_IP_JOIN_GROUP_FAILED: [chars]: failed to join glbp 
multicast address group 

Explanation    The system was unable to peform a join to start receiving GLBP protocol packets.

Recommended Action    Please check syslog messages for IP failures and rectify the problem

Error Message     GLBP-3-GLBP_IP_LEAVE_GROUP_FAILED: [chars]: failed to leave glbp 
multicast address group 

Explanation    The system was unable to peform a leave to stop receiving GLBP protocol packets.

Recommended Action    Please check syslog messages for IP failures and rectify the problem

Error Message     GLBP-3-GLBP_MAC_ADD_FAILED: fwd [dec] failed to add [chars] in mac 
table (error [hex]) 

Explanation    The system was unable to add the GLBP mac address into the mac addresss table

Recommended Action    Please check syslog messages for L2FM failures and rectify the problem

Error Message     GLBP-3-GLBP_MAC_DEL_FAILED: fwd [dec] failed to delete [chars] in mac 
table (error [hex]) 

Explanation    The system was unable to delete the GLBP mac address from the mac addresss table

Recommended Action    Please check syslog messages for L2FM failures and rectify the problem

Error Message     GLBP-3-GLBP_ROUTE_ADD_FAILED: failed to add [chars] in routing table 

Explanation    The system was unable to add the GLBP vIP address into the unicast routing table

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

Error Message     GLBP-3-GLBP_ROUTE_DEL_FAILED: failed to delete [chars] in routing 
table 

Explanation    The system was unable to delete the GLBP vIP address from the unicast routing table

Recommended Action    Please check syslog messages for URIB failures and rectify the problem

GLBP-4

Error Message     GLBP-4-BADAUTH: Bad authentication received from [chars] 

Explanation    Two routers participating in a Gateway Load Balancing Protocol group have a valid authentication string that does not match.

Recommended Action    Use the glbp authentication interface command to repair the Gateway Load Balancing Protocol authentication discrepancy between the local system and the one whose IP address is reported

Error Message     GLBP-4-BADVIP1: address [chars] is in the wrong subnet for this 
interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address is not within the subnet configured on this interface.

Recommended Action    Configure the virtual IP address of Gateway Load Balancing Protocol to be within the subnet configured on this interface.

Error Message     GLBP-4-BADVIP2: address [chars] in the wrong subnet for this interface 
is not learned 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is not within the subnet configured on this interface.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-BADVIP3: address [chars] is the broadcast address for this 
interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address is a broadcast address for this interface.

Recommended Action    Configure the virtual IP address of Gateway Load Balancing Protocol to be a non broadcast address.

Error Message     GLBP-4-DIFFVIP1: active router virtual IP address [chars] is different 
from the locally configured virtual IP address [chars]

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the Hello message from the Active router is different to that configured locally.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers

Error Message     GLBP-4-DUPADDR: Duplicate address on [chars] 

Explanation    The IP address in a Gateway Load Balancing Protocol message received on the interface is the same as the IP address of its own router. This condition may be caused by a misconfiguration or because of a malfunctioning switch.

Recommended Action    Check the configurations on all the Gateway Load Balancing Protocol routers, and ensure that any switches are functioning properly

Error Message     GLBP-4-DUPVIP1: address [chars] already assigned to interface [chars] 
grp [dec] 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to a different Gateway Load Balancing Protocol group.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers

Error Message     GLBP-4-DUPVIP2: address [chars] already assigned to this interface 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to this interface.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-DUPVIP3: address [chars] already assigned to another interface 
[chars] 

Explanation    The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to, or overlaps with, an address on another interface or application.

Recommended Action    Check the configuration on all Gateway Load Balancing Protocol routers.

Error Message     GLBP-4-GLBP_ARP_RESP_FAILED: failed to send arp response 
[chars]/[chars] 

Explanation    The system was unable to send the arp response for vIP

Recommended Action    Please check syslog messages for ARP failures and rectify the problem

GLBP-5

Error Message     GLBP-5-ACTIVE_CHANGE: Active gateway is [chars] 

Explanation    The Gateway Load Balancing Protocol has changed active gateway.

Recommended Action    No action is required

Error Message     GLBP-5-FWDSTATECHANGE: fwd [dec] state changed from [chars] to [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed state.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_CREATE: fwd [dec] created 

Explanation    The Gateway Load Balancing Protocol forwarder has been created.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_DELETE: fwd [dec] deleted 

Explanation    The Gateway Load Balancing Protocol forwarder has been removed.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_OWNER: fwd [dec] owner mac is [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the owner MAC address.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_VMAC: fwd [dec] virtual mac is [chars] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the virtual MAC address.

Recommended Action    No action is required

Error Message     GLBP-5-FWD_WEIGHTING: fwd [dec] weighting is [dec] 

Explanation    The Gateway Load Balancing Protocol forwarder has changed the weighting.

Recommended Action    No action is required

Error Message     GLBP-5-GRPSTATECHANGE: state changed from [chars] to [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has changed state.

Recommended Action    No action is required

Error Message     GLBP-5-MEMBER_ADD: member [chars] [chars] added 

Explanation    The Gateway Load Balancing Protocol gateway has added a member.

Recommended Action    No action is required

Error Message     GLBP-5-MEMBER_REMOVE: member [chars] [chars] removed 

Explanation    The Gateway Load Balancing Protocol gateway has removed a member.

Recommended Action    No action is required

Error Message     GLBP-5-PRIORITY: [chars] gateway priority changed to [dec] 

Explanation    The Gateway Load Balancing Protocol gateway has changed priority.

Recommended Action    No action is required

Error Message     GLBP-5-STANDBY_CHANGE: Standby gateway is [chars] 

Explanation    The Gateway Load Balancing Protocol has changed standby gateway.

Recommended Action    No action is required

Error Message     GLBP-5-TIMER: [chars] timer changed to [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has learnt timers.

Recommended Action    No action is required

Error Message     GLBP-5-VIPLEARN: learnt virtual ip address [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has learnt virtual IP address.

Recommended Action    No action is required

Error Message     GLBP-5-VIPUNLEARN: unlearnt virtual ip address [chars] 

Explanation    The Gateway Load Balancing Protocol gateway has unlearnt virtual IP address.

Recommended Action    No action is required

Error Message     GLBP-5-WEIGHTING: weighting changed to [dec] 

Explanation    The Gateway Load Balancing Protocol gateway has changed the weighting.

Recommended Action    No action is required

HSRP_ENGINE Messages

This section contains the HSRP_ENGINE messages.

HSRP_ENGINE-3

Error Message    HSRP_ENGINE-3-NOSOCKET: Unable to open socket 

Explanation    The system was unable to initialize an IP connection for the Hot Standby protocol.

Recommended Action    Make sure that there is at least one interface configured to run IP.

HSRP_ENGINE-4

Error Message     HSRP_ENGINE-4-BADAUTH2: Bad authentication from [chars] 

Explanation    Two routers participating in HSRP disagree on the valid authentication string.

Recommended Action    Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.

Error Message     HSRP_ENGINE-4-BADAUTH: Bad authentication from [chars], group [dec], 
remote state [chars] 

Explanation    Two routers participating in HSRP disagree on the valid authentication string.

Recommended Action    Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.

Error Message     HSRP_ENGINE-4-DIFFVIP1: [chars] Grp [dec] active routers virtual IP 
address [chars] is different to the locally configured address [chars]

Explanation    The HSRP virtual IP address contained in the Hello message from the Active router is different to that configured locally.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPADDR: Duplicate address %i on [chars], sourced by %e 

Explanation    The IP address in an HSRP message received on the interface is the same as the router's own IP address. This may be because of misconfiugration, or because of a malfunctioning switch

Recommended Action    Check the configurations on all the HSRP routers, and make sure that any switches you have are functioning properly.

Error Message     HSRP_ENGINE-4-DUPVIP1: [chars] Grp [dec] address [chars] is already 
assigned to a HSRP group on this interface

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different HSRP group.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPVIP2: [chars] Grp [dec] address [chars] is already 
assigned on this interface

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface.

Recommended Action    Check the configuration on all HSRP routers.

Error Message     HSRP_ENGINE-4-DUPVIP3: [chars] Grp [dec] address [chars] is already 
assigned to, or overlaps with, an address on another interface or application

Explanation    The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with, an address on another interface or application.

Recommended Action    Check the configuration on all HSRP routers.

HSRP_ENGINE-6

Error Message     HSRP_ENGINE-6-ACTIVEROUTERPRIORITY: Interface [chars] [chars] Grp 
[dec] Active router priority changed to [dec] 

Explanation    The priority of the Active router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-ACTIVE_CHANGE: Interface [chars] [chars] Grp [dec] 
Active router is [chars] 

Explanation    The Active router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-GRPSTATECHANGE: Interface [chars] [chars] Grp [dec] 
state changed from [chars] to [chars] reason [chars] 

Explanation    The HSRP router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-MACADDRESS_CHANGE: Interface [chars] [chars] Grp [dec] 
mac-address changed to [chars] 

Explanation    The mac address of the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-PRIORITY: Interface [chars] [chars] Grp [dec] priority 
changed to [dec] 

Explanation    The current priority of the HSRP group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STANDBYROUTERPRIORITYCHANGE: Interface [chars] [chars] 
Grp [dec] Standby router priority changed to [dec] 

Explanation    The priority of the Standby router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STANDBY_CHANGE: Interface [chars] [chars] Grp [dec] 
Standby router is [chars] 

Explanation    The Standby router for the group has changed.

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STATECHANGE2: [chars] Grp [dec] state moving from 
[chars] 

Explanation    The router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-STATECHANGE: [chars] Grp [dec] state move to [chars] 

Explanation    The router has changed state

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-TIMER: Interface [chars] [chars] Grp [dec] [chars] 
timer changed to [dec] [chars] 

Explanation    The hello/hold timer value for the HSRP group has changed

Recommended Action    No action is required.

Error Message     HSRP_ENGINE-6-VIPLEARN: Interface [chars] [chars] Grp [dec] learnt 
virtual ip address [chars] 

Explanation    The local router has learnt virtual ip address from the incoming HSRP packet.

Recommended Action    No action is required.

IKE Messages

This section contains the IKE messages.

IKE-3

Error Message    IKE-3-CRYPTO_INIT_ERROR: IKEv2 crypto init error: [chars] 

Explanation    Crypto initialization error

Recommended Action    No action is required.

Error Message     IKE-3-ENABLE_ERROR: Unable to store enable flag in configuration 
(error-id [hex]).

Explanation    Service failed to store the enable flag in configuration. As a result, it will exit

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IKE-3-FIPS_MODE_ERROR: Could not set FIPS mode 

Explanation    The FIPS mode could not be set by IKE

Recommended Action    No action is required.

Error Message     IKE-3-IKE_PROGRAM_EXIT: [chars] 

Explanation    IKE process did an abnormal exit

Recommended Action    No action is required.

Error Message     IKE-3-MAX_HALF_CONN_LIMIT_REACHED: IKEv1 : Exceeded the limit for 
number of half open Phase 1 connections 

Explanation    The number of half open connections has exceeded the maximum limit

Recommended Action    No action is required.

Error Message     IKE-3-PHASE1_NEGOTIATION_FAILED: IKEv1: Phase 1 negotiation failed 
for peer [chars] 

Explanation    IKE policy negotiation failed for peer [chars].

Recommended Action    No action is required.

Error Message     IKE-3-PHASE1_PROPOSAL_MISMATCH: IKEv1: No matching phase 1 proposal 
found for peer [chars] 

Explanation    There is a IKE policy mismatch for the peer.

Recommended Action    No action is required.

Error Message     IKE-3-PHASE2_NEGOTIATION_FAILED: IKEv1: Phase 2 negotiation failed 
for peer [chars] 

Explanation    IPsec policy negotiation failed for peer [chars].

Recommended Action    No action is required.

Error Message     IKE-3-PHASE2_PROPOSAL_MISMATCH: IKEv1: No matching phase 2 proposal 
found for peer [chars] 

Explanation    There is a IPsec policy mismatch for the peer.

Recommended Action    No action is required.

Error Message     IKE-3-UNSUPPORTED_EXCHANGE: IKEv1: Unsupported exchange [dec] 
received from [chars] 

Explanation    A unsupported IKE exchange type [digits] was received from [chars]

Recommended Action    No action is required.

IKE-4

Error Message     IKE-4-INVALID_PAYLOAD_APPEAR: IKEv2 received message (from [chars]) 
with payload ([chars]) appeared in [chars]([chars]) 

Explanation    Received a payload in an inappropriate exchange

Recommended Action    No action is required.

Error Message     IKE-4-MESSAGE_ERROR: IKEv2 message (from [chars]) message error: 
[chars] 

Explanation    Received a malformed message which doesn't adhere to the protocol

Recommended Action    No action is required.

Error Message     IKE-4-PARSING_ERROR: IKEv2 message (from [chars]) parsing error: 
[chars] 

Explanation    Received a malformed message which can not be parsed appropriately

Recommended Action    No action is required.

Error Message     IKE-4-UNKNOWN_PAYLOAD: IKEv2 received message (from [chars]) with 
un-recognized payload ([chars]) 

Explanation    Received an invalid payload

Recommended Action    No action is required.

Error Message     IKE-4-UNSUPPORT: [chars] is not supported (message from [chars]) 

Explanation    Received something unsupported

Recommended Action    No action is required.

IKE-6

Error Message     IKE-6-POLL_START_DONE: IKE is exiting since it is not enabled 

Explanation    IKE is exiting since it is not enabled in the configuration

Recommended Action    No action is required.

ILC-SPAN Messages

This section contains the ILC-SPAN messages.

ILC-SPAN-3

Error Message    ILC-SPAN-3-ERROR: [chars] 

Explanation    Ilc_span_mgr encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

ILC_HELPER Messages

This section contains the ILC-HELPER messages.

ILC_HELPER-2

Error Message    ILC_HELPER-2-NO_LICENSE_REBOOT: Linecard [dec] will reboot now. 

Explanation    SSE License has expired, hence the linecard will be rebooted.

Recommended Action    Install appropriate SSE license to be able to use SSM features normally

ILC_HELPER-3

Error Message     ILC_HELPER-3-INVALID_SSI: [chars] 

Explanation    The ssi boot variable is configured to an invalid image. So, the linecard will be bought online in basic mode instead of advanced SSI mode

Recommended Action    Configure a proper image for the ssi boot variable

ILC_HELPER-6

Error Message     ILC_HELPER-6-LICENSE_VALID: A valid license for linecard [dec] has 
been obtained 

Explanation    A valid license has been obtained for the SSM

Recommended Action    No action is required.

Error Message     ILC_HELPER-6-UPGRADE_DELAY: The SSI upgrade on slot [dec] is delayed 
by [dec] secs. 

Explanation    The SSI upgrade is delayed due to the configured ssm upgrade delay command

Recommended Action    No action is required.

IMAGE_DNLD Messages

This section contains the IMAGE_DNLD messages.

IMAGE_DNLD-SLOT#-2

Error Message    IMAGE_DNLD-SLOT#-2-ADDON_IMG_DNLD_FAILED: Module image download 
process failed. [chars] 

Explanation    Addon image download to module failed. This module is not operational until an addon image has been successfully installed.

Recommended Action    Verify the location and version of your module image. Use the install module cli command to download a new module image.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_COMPLETE: Module image download process. 
[chars] 

Explanation    Image download completed. Module image is being installed.

Recommended Action    No action is required.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_FAILED: Module image download process. 
[chars] 

Explanation    Image download failed. Module may be inoperable.

Recommended Action    Use show module cli command to verify the state of this module. Retry image download with install module cli command.

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_FILE_SYSTEM_CHECK_ERROR: File System 
check failed: [chars] 

Explanation    File system consistency check failed

Recommended Action    File-system repair is needed using fsck

Error Message     IMAGE_DNLD-SLOT#-2-IMG_DNLD_STARTED: Module image download process. 
[chars] 

Explanation    Image download started. Module image downloads are non-disruptive to module operation.

Recommended Action    No action is required.

IMAGE_DNLD-SLOT#-4

Error Message     IMAGE_DNLD-SLOT#-4-IMG_DNLD_FILE_SYSTEM_RECREATION: [chars]. 
Partition was erased and successfully recreated. 

Explanation    File system checking and recreation if necessary for \/images\.

Recommended Action    No action is required.

IMAGE_DNLD-SLOT#-5

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_COMPLETE: Addon module image 
download process completed. [chars] 

Explanation    Addon image download to module has completed.The module should now be installing this new image.

Recommended Action    This message is informational only.

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_STARTED: Addon module image 
download process started. [chars] 

Explanation    Addon image download to module has started. This is a disruptive download and this module will be inoperable until this download process is complete.

Recommended Action    This message is informational only.

Error Message     IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_SUCCESSFUL: Addon module image 
download and install process successful. [chars] 

Explanation    Addon image download and install to module is successful.

Recommended Action    Use the show module cli command to verify the module's operational status.

IMAGE_UPGRADE Messages

This section contains the IMAGE_UPGRADE messages.

IMAGE_UPGRADE-SLOT#-2

Error Message    IMAGE_UPGRADE-SLOT#-2-IMAGE_UPGRADE_ERROR: [chars] 

Explanation    Image Upgrade Error

Recommended Action    No action is required.

IMAGE_UPGRADE-SLOT#-4

Error Message     IMAGE_UPGRADE-SLOT#-4-IMAGE_UPGRADE_INFO: [chars] 

Explanation    Image Upgrade Info

Recommended Action    No action is required.

IM Messages

This section contains the IM messages.

IM-3

Error Message    IM-3-IM_LC_OFFLINE_ERROR: LC Offline could not be sent to vdc:[dec] 

Explanation    LC Offline was not relayed to some vdc, so applications may not behave correctly.

Recommended Action    No action is required.

Error Message     IM-3-IM_RESP_ERROR: Component [chars] opcode:[chars] in vdc:[dec] 
returned error:[chars] 

Explanation    Some component returned an error.

Recommended Action    No action is required.

Error Message     IM-3-IM_SEQ_ERROR: Error ([chars]) while communicating with component 
[chars] opcode:[chars] (for:[chars]) 

Explanation    Some component did not respond to a request in stipulated time.

Recommended Action    No action is required.

IM-5

Error Message     IM-5-IM_DEMUX_ERROR: [chars] 

Explanation    Demux function returned error

Recommended Action    No action is required.

Error Message     IM-5-IM_INTERNAL_ERROR: [chars] 

Explanation    Internal error occurred

Recommended Action    No action is required.

Error Message     IM-5-IM_INTF_STATE: [chars] [chars] in vdc [dec] 

Explanation    Management interface state changed.

Recommended Action    No action is required.

Error Message     IM-5-IM_UNKNOWN_INTERFACE: [chars] 

Explanation    Interface is not supported or not found

Recommended Action    No action is required.

INTERFACE_VLAN Messages

This section contains the INTERFACE_VLAN messages.

INTERFACE_VLAN-5

Error Message    INTERFACE_VLAN-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is 
down(Administratively Down) 

Explanation    Interface has been configured to be administratively down

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-IF_DOWN_ERROR_DISABLED: Interface [chars] is down. 
Reason [dec] 

Explanation    The interface encountered an error while configuring it

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-IF_DOWN_INACTIVE: Interface [chars] is down 
(Inactive) 

Explanation    Interface VLAN has been suspended or deleted

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_DISABLED: SVI Disabled 

Explanation    SVI Service Disabled

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_ENABLED: SVI Enabled 

Explanation    SVI Service Enabled

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_GET_MAC_FAILED: Failed to acquire MAC address 
for SVI [hex] 

Explanation    SVI failed to acquire MAC address

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_INIT: SVI intialization failed with error [hex] 

Explanation    SVI initialziation error

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_MTS_SEND_FAILURE: MTS send failure for opcode 
[dec], error [hex] 

Explanation    SVI encountered an error in with MTS message

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_MTS_TIME_OUT: MTS send timed out 

Explanation    SVI did not recieve response for mts message

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_RSRVD_VLAN_FAILED: Failed to get list of 
reserved vlans [hex] 

Explanation    SVI failed to get the list reserved vlans

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_SDB_UPDATE_FAILED: sdb update failed with 
ret_val [dec] 

Explanation    SDB updated failed for SVI

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-SVI_SEC_VLAN_FAILED: Failed to get list of secondary 
vlans [hex] 

Explanation    SVI failed to get the list of secondary vlans

Recommended Action    No action is required.

Error Message     INTERFACE_VLAN-5-UPDOWN: Line Protocol on Interface [chars], changed 
state to [chars] 

Explanation    Line protocol status changed for an interface

Recommended Action    No action is required.

IOA_LC Messages

This section contains the IOA_LC messages.

IOA_LC-5

Error Message    IOA_LC-5-IOA_DISABLED: IOA Disabled 

Explanation    IOA Service Disabled

Recommended Action    No action is required.

Error Message     IOA_LC-5-IOA_ENABLED: IOA Enabled 

Explanation    IOA Service nabled

Recommended Action    No action is required.

IPACL Messages

This section contains the IPACL messages.

IPACL-0

Error Message    IPACL-0-EMERG: [chars] 

Explanation    Ipacl caused a system failure

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-1

Error Message     IPACL-1-ALERT: [chars] 

Explanation    Ipacl caused failures in other services

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-2

Error Message     IPACL-2-CRIT: [chars] 

Explanation    Ipacl encountered a catastrophic error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPACL-3-ERR: [chars] 

Explanation    Ipacl encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPACL-4

Error Message     IPACL-4-WARN: [chars] 

Explanation    Ipacl ignored the unexpected condition

Recommended Action    Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.

IPACL-5

Error Message     IPACL-5-NOTE: [chars] 

Explanation    Ipacl does not support this operation

Recommended Action    Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.

IPACL-6

Error Message     IPACL-6-INFO: [chars] 

Explanation    Ipacl event occurred

Recommended Action    No action is required.

IPFC Messages

This section contains the IPFC messages.

IPFC-2

Error Message    IPFC-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The service failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IPFC-3

Error Message     IPFC-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

Error Message     IPFC-3-IOCTL_FAILED: IOCTL failed 

Explanation    An IOCTL to the character device failed.

Recommended Action    Show IPFC internal interface VSAN <number> for all the configured VSAN interfaces to check the internal status, show IPFC internal MIP to check the internal status.

Error Message     IPFC-3-PSSERROR: [chars] 

Explanation    IPFC manager encountered a PSS error.

Recommended Action    No action is required.

IPFC-5

Error Message     IPFC-5-CONFIG_EVENT: VSAN interface [dec] [chars] 

Explanation    The specified VSAN Interface has been successfully [chars].

Recommended Action    No action is required.

Error Message     IPFC-5-STATE_CHANGE: VSAN interface [dec] [chars] 

Explanation    The specified VSAN Interface is [chars].

Recommended Action    No action is required.

IPFC-6

Error Message     IPFC-6-STARTING: IP Over Fiber Channel service started 

Explanation    The service has successfully started.

Recommended Action    No action is required.

IPPOOL Messages

This section contains the IPPOOL messages.

IPPOOL-3

Error Message    IPPOOL-3-NO_VC_CONNECTIVITY: Please check if you are connected to 
vCenter Server 

Explanation    Please check if you are connected to vCenter Server

Recommended Action    No action is required.

IPPOOL-5

Error Message     IPPOOL-5-IPPOOL_DISABLED: IPPOOL Disabled 

Explanation    IPPOOL Service Disabled

Recommended Action    No action is required.

Error Message     IPPOOL-5-IPPOOL_ENABLED: IPPOOL Enabled 

Explanation    IPPOOL Service enabled

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_CREATED: Vmknic Created for module [dec] 

Explanation    Vmknic created

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_DELETED: Vmknic Deleted for module [dec] 

Explanation    Vmknic deleted

Recommended Action    No action is required.

Error Message     IPPOOL-5-VMKNIC_UPDATED: Vmknic updated for module [dec] 

Explanation    Vmknic updated

Recommended Action    No action is required.

IPQOSMGR Messages

This section contains the IPQOSMGR messages.

IPQOSMGR-2

Error Message    IPQOSMGR-2-QOSMGR_HA_FAILURE: Failed to do high availability 
operation: [chars]. 

Explanation    Failed to do high availability operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_INIT_FAILED: Initialization failed for QoS Manager: 
[chars], reason: [hex]. 

Explanation    Initialization failed for QoS Manager due to [chars], reason: [hex].

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_MTS_FAILURE: Failed to do MTS operation: [chars]. 

Explanation    Failed to do MTS operation. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_MTS_REGISTRATION_FAILED: MTS options setting to 
[hex] failed for opCode: [dec]. 

Explanation    MTS options setting to [hex] failed for opCode: [dec].

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_PSS_FAILURE: Failed to do PSS operation: [chars], 
reason: [hex]. 

Explanation    Failed to do PSS operation [chars]. [hex] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-2-QOSMGR_PSS_VER_FAIL: PSS file [chars] has version 
[dec].[dec].[dec], expected version [dec].[dec].[dec]. 

Explanation    There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.

Recommended Action    No action is required.

IPQOSMGR-3

Error Message     IPQOSMGR-3-QOSMGR_CONFIG_ERROR: Configuration error: [chars]. 

Explanation    Configuration error. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-3-QOSMGR_PPF_ERROR: PPF library error: [chars]. 

Explanation    PPF library errors. [chars] is the reason.

Recommended Action    No action is required.

IPQOSMGR-4

Error Message     IPQOSMGR-4-QOSMGR_LC_ERROR_MSG: Linecard [dec] returned an error: 
[chars] 

Explanation    Linecard [dec] returned an error message which is reported as [chars].

Recommended Action    No action is required.

Error Message     IPQOSMGR-4-QOSMGR_PPF_WARNING: PPF library warning: [chars]. 

Explanation    PPF library warning. [chars] is the reason.

Recommended Action    No action is required.

Error Message     IPQOSMGR-4-QOSMGR_WARNING_MSG: [chars] [dec] 

Explanation    QOSMGR warning messages is reported as [chars] [dec].

Recommended Action    No action is required.

IPQOSMGR-6

Error Message     IPQOSMGR-6-QOSMGR_STATUS: QOSMGR Status: [chars]. 

Explanation    QOSMGR status is reported as [chars].

Recommended Action    No action is required.

IPQOSMGR-SLOT#-3

Error Message     IPQOSMGR-SLOT#-3-QOSMGR_DPA_MSG: DPA returned error message - [chars] 

Explanation    An error occured in the DPA [string] is the error message.

Recommended Action    No action is required.

IPSEC Messages

This section contains the IPSEC messages.

IPSEC-2

Error Message    IPSEC-2-IPSEC_INIT: IPSec initialization of [chars] [chars] 

Explanation    IPSec initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPSEC-2-IPSEC_SPD_OVERFLOW_DUE_TO_ACL: SPD Overflow on interface due 
to IP ACL [chars] bound to crypto map [chars] [dec]

Explanation    Modifying IP ACL caused Security Policy Database on the interface to overflow, IP ACL filter not applied to security policy database

Recommended Action    Undo IP ACL change

IPSEC-3

Error Message     IPSEC-3-14_2_MODULE_PACKETS_DROPPED: [chars]: packets were dropped in 
the module 

Explanation    Packets dropped in the 14/2 module. Please collect drop statistics using \show ipsec internal crypto-acc interface gigabit <slot/port> stats\

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPSEC-3-IPSEC_FIPS_TEST_FAILED: IPSEC FIPS compliance test failed 

Explanation    IPSEC FIPS compliance test failed

Recommended Action    No action is required.

Error Message     IPSEC-3-IPSEC_MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: 
[chars] 

Explanation    Failed to send a message

Recommended Action    No action is required.

IPSEC-5

Error Message     IPSEC-5-IPSEC_CMS_IF_ACL_UPDATED: IP ACL [chars] updated while Crypto 
map [chars] [dec] bound to interface(s)

Explanation    IP ACL updated while it is mapped to a crypto map that is bound to interface(s)

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_DISABLED_LIC_EXPIRED: IPSec Disabled due to License 
Expiry 

Explanation    IPSec Disabled due to License Expiry

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_DISABLED: IPSec Disabled 

Explanation    IPSec Disabled

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_ENABLED: IPSec Enabled 

Explanation    IPSec Enabled

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_CREATED: [chars]: IPSec SA created: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]) 

Explanation    IPSec SA created

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_DELETED: [chars]: IPSec SA deleted: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]), reason: [chars] 

Explanation    IPSec SA deleted

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_SA_REKEYED: [chars]: IPSec SA rekeyed: local_ip: 
[chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]) 

Explanation    IPSec SA rekeyed

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_CREATED: [chars]: IPSec tunnel created: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: 
local: [chars]/[chars], port: [chars], remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel created

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_DELETED: [chars]: IPSec tunnel deleted: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: 
local: [chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel deleted

Recommended Action    No action is required.

Error Message     IPSEC-5-IPSEC_TUNNEL_REKEYED: [chars]: IPSec tunnel rekeyed: 
local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars] traffic:: local: 
[chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars] 

Explanation    IPSec tunnel rekeyed

Recommended Action    No action is required.

IPS_SB_MGR Messages

This section contains the IP_SB_MGR messages.

IPS_SB_MGR-SLOT#-2

Error Message    IPS_SB_MGR-SLOT#-2-NODE_CORE_NOT_RESPONDING: [Node [dec], Core 
[dec]]: Not responding to heartbeats, state=[hex] 

Explanation    Node is not incrementing heartbeats periodically

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-NODE_NOT_RESPONDING: [Node [dec], Core [dec]] : 
Not responding to heartbeats 

Explanation    Node manager is not receiving heartbeat responses from the node

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-NODE_REIMAGE_PREPARE_FAIL: [Node [dec]]: Disk 
formatting failed during node install 

Explanation    There was a problem during the partitioning of disk and creation of file systems during node install.

Recommended Action    Potential node software issue. Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-2-PORT_SOFTWARE_FAILURE: Port software failure, 
module [dec] port [dec] 

Explanation    The software servicing the data path on the port has failed

Recommended Action    No action is required.

IPS_SB_MGR-SLOT#-3

Error Message     IPS_SB_MGR-SLOT#-3-COMP_FAILURE: Heartbeat failure in compression 
engine (error [hex]) 

Explanation    The compression engine did not respond to heartbeats, due to some failure. SAN-OS will restart the compression engine to clear the problem.

Recommended Action    No action is required.

Error Message     IPS_SB_MGR-SLOT#-3-CRYPTO_FAILURE: Heartbeat failure in encryption 
engine (error [hex]) 

Explanation    The encryption engine did not respond to heartbeats, due to some failure. SAN-OS will restart the encryption engine to clear the problem.

Recommended Action    No action is required.

IPS_SB_MGR-SLOT#-4

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_ADD_ON: svc-node[dec] image 
is not compatible with svclc image 

Explanation    The svc image on the node is not compatible with the add on image running on the linecard.

Recommended Action    Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_CURRENT: svc-node[dec] image 
is not compatible with current node image 

Explanation    The new svc image is not compatible with the svc image currently running on the node

Recommended Action    Please contact your support representative

Error Message     IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_SUP: svc-node[dec] image is 
not compatible with system image 

Explanation    The svc image on the node is not compatible with the supervisor image.

Recommended Action    Please contact your support representative

IPS_SB_MGR-SLOT#-6

Error Message     IPS_SB_MGR-SLOT#-6-SBMGR_EVENT: Sbmgr event: [chars] 

Explanation    This is an event log of sb_mgr relating to a port/node

Recommended Action    No action is required.

IPS Messages

This section contains the IPS messages.

IPS-2

Error Message    IPS-2-ISCSI_IPS_INIT: IPS initialization of [chars] [chars] 

Explanation    IPS initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IPS-3

Error Message     IPS-3-FCIP_FTA_ACCEL_CHAIN_ABORTED: Exch Aborted FC oxid [hex] My 
oxid [hex] State [chars] Event [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] 
CUI: [hex] DA [hex] VSAN: [dec] (Internal [hex]:[hex])

Explanation    FTA Exch being aborted

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_DATA_SENSE: Sense data with ERA [hex] sent to CH FCID: 
[hex] CHI: [hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Sense data with ERA sent

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_ERA_35: ERA [hex] presented to CH FCID: [hex] CHI: 
[hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP got an ERA 35

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_ERA_38: ERA 0x38 received CH FCID: [hex] CHI: [hex] 
from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] at tape capacity: [dec] MB

Explanation    FCIP got an ERA 38

Recommended Action    SYSLOGDOC_CONTACT_TAC

Error Message     IPS-3-FCIP_FTA_LOCATE_RBID_MISMATCH: Permanent Error due to Locate 
RBID Mismatch, CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: 
[dec]

Explanation    FCIP-FTA got a Permanent Error

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_PERM_ERR: Permanent Error, ERA [hex] rcvd CH FCID: 
[hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] sense_byte[2,6]: 
[[hex], [hex]]

Explanation    FCIP-FTA got a Permanent Error

Recommended Action    Informational no action required

Error Message     IPS-3-FCIP_FTA_RETRY_ERROR: [chars] retries [dec] FC oxid [hex] My 
oxid [hex] State [chars] Event [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] 
CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FTA Command timed out

Recommended Action    Informational no action required

Error Message     IPS-3-IPS_CRYPTO_FIPS_FAILED: IPS module [dec] has failed FIPS tests. 
FIPS info - [chars] 

Explanation    FIPS error occurred in the IPS module.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-IPS_EGRESS_PERR: Parity error on dma-bridge egress. Count: 
[dec] 

Explanation    Parity error occured in dma-bridge egress direction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-IPS_FIPS_TEST_FAILED: IPS FIPS compliance test failed 

Explanation    IPS FIPS compliance test failed

Recommended Action    No action is required.

Error Message     IPS-3-IPS_INGRESS_PERR: Parity error on dma-bridge ingress. Count: 
[dec] 

Explanation    Parity error occured in dma-bridge ingress direction.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_COMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while commiting the cfs config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_CONFIG_FAILED: [chars]; [chars] 

Explanation    An error occurred while distributing the CFS config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_ACTIVATION_FAILED: [chars]; [chars] 

Explanation    An error occurred while activating merged configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_CLEARED: [chars] 

Explanation    Merge cleared, reason: [chars]

Recommended Action    No action is required.

Error Message     IPS-3-ISLB_CFS_MERGE_COMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while commiting the cfs merge config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_CONFIG_FAILED: [chars]; [chars] 

Explanation    An error occurred while distributing the CFS merge config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_FAILED: [chars]; [chars] 

Explanation    An error occurred while merging the iSLB CFS fabrics. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_PRECOMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while precommiting merge data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_MERGE_REQ_REJECTED: [chars] 

Explanation    Merge requested rejected, reason: [chars]

Recommended Action    No action is required.

Error Message     IPS-3-ISLB_CFS_MERGING_CONFIG_DB_FAILED: [chars]; [chars] 

Explanation    An error occurred while merging the config data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PRECOMMIT_FAILED: [chars]; [chars] 

Explanation    An error occurred while precommiting data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PWWN_RESV_CLAIM_FAILED: [chars] 

Explanation    PWWN reservation claim failed. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_PWWN_RESV_RELEASE_FAILED: [chars] 

Explanation    PWWN reservation release failed. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the CFS lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_CFS_VRRP_DIST_FAILED: [chars] 

Explanation    An error occurred while distributing the VRRP CFS runtime data. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_ZONE_ACTIVATION_FAILED: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IPS-3-ISLB_ZONE_ACTIVATION_RETRY: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed. Zone server busy.

Recommended Action    Retry the iSLB zonest activation.

Error Message     IPS-3-ISLB_ZONE_NO_ACTIVE_ZONESET: iSLB zoneset activation returned 
[hex] for VSAN [dec] 

Explanation    ISLB zoneset activation failed. No active zoneset.

Recommended Action    Activate a zoneset in the specified VSAN and retry

IPS-4

Error Message     IPS-4-FCIP_FTA_CFG_MISMATCH: [chars]: Mismatch in FCIP Ficon Tape 
Acceleration configuration with peer

Explanation    The FCIP Ficon Tape Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Ficon Tape Acceleration configuration to be consistent with the peer

Error Message     IPS-4-FCIP_FTA_VSAN_UPDATE_WARNING: FCIP FICON tape acceleration VSAN 
update had an error ([chars]) on interface [chars] causing a flap of the interface

Explanation    The FCIP FICON tape acceleration VSAN configuration experienced an error when disabling and enabling the VSAN over the FCIP tunnel. The FCIP tunnel was disabled and re-enabled as a result of this error to ensure data integrity.

Recommended Action    No action is required.

Error Message     IPS-4-FCIP_LICENSE_BIND_FAILED: Bind failed for [chars] due to 
[chars] for license failure; configuration accepted but bind failed

Explanation    The FCIP configuration was accepted, but the FCIP interface did not bind to a physical interface because the appropriate license was not available. If a license becomes available in the future, this FCIP interface will bind to a physical interface automatically.

Recommended Action    Check the license state with show license usage and acquire the necessary FCIP license

Error Message     IPS-4-FCIP_XRCE_LICENSE_FAILED: XRC Acceleration deactivated due to 
license failure 

Explanation    The XRC Acceleration configuration was accepted, but will remain inactive until a valid license is available. When the appropriate license is installed, XRC accelaration will be activated.

Recommended Action    Check the license state with show license usage and acquire the necessary XRC_ACCL license

Error Message     IPS-4-FCIP_XRCE_LICENSE_INSTALLED: XRC Acceleration activated due to 
valid license 

Explanation    The XRC Acceleration configuration is activated as a valid license has been installed.

Recommended Action    No action is required.

IPS-5

Error Message     IPS-5-FCIP_BIND_FAILED: Bind failed for [chars] due to [chars] for 
[chars] 

Explanation    FCIP/ISCSI Interface bind to Ethernet port failed

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_BPORT_KEEPALIVES_NOT_SUPPORTED: Bport Keepalives not 
supported for FCIP [chars] 

Explanation    Bport Keepalives not supported in this release

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_BPORT_NOT_SUPPORTED: Bport not supported for FCIP [chars] 

Explanation    Bport not supported in this releas

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ACCEL_STARTED: Acceleration started for CH FCID: [hex] 
CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP-FTA Acceleration started

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ACCEL_STOPPED: Acceleration stopped for CH FCID: [hex] 
CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] due to [chars] after [dec] 
MB writes

Explanation    FCIP-FTA Acceleration stopped

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ALREADY_OFF: FTA Already Off, [chars] VSAN: [dec] 

Explanation    FTA Already Off

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_ALREADY_ON: FTA Already ON, [chars] VSAN: [dec] 

Explanation    FTA Already ON

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_CB_DOWN: FTA [chars] is DOWN 

Explanation    FTA is DOWN

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_CB_UP: FTA [chars], is UP 

Explanation    FTA is UP

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_DISBAND_GRP_CMD: Disband Group message processed PGID: 
[chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP Disbanded a Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_EST_GRP_CMD: Path Group establised for PGID: [chars] 
CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP established a Path Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS1: RSCN Cleanup Pass1 
[chars] FCID1: [hex] FCID2: [hex] VSAN: [dec] 

Explanation    Doing RSCN Cleanup, Pass 1

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS2: RSCN Cleanup Pass2 
[chars] FCID1: [hex] FCID2: [hex] VSAN: [dec] 

Explanation    Doing RSCN Cleanup, Pass 2

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESIGN_GRP_CMD: Resign group processed for PGID: 
[chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP Resigned a Group

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_3490: 3490 device discovered by FCIP CH FCID: 
[hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Device type discovered is 3490

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_3590: 3590 device discovered by FCIP CH FCID: 
[hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    Device type discovered is 3590

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_RESP_NOT_TAPE: Non-tape device discovered by FCIP CH 
FCID: [hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]

Explanation    FCIP discovered a non-tape device

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_OFF_LAST_VSAN: FTA turned off for the Last VSAN, 
[chars] VSAN: [dec] 

Explanation    FTA turned off for the Last Vsan

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_OFF_NONLAST_VSAN: FTA turned off for the Non-Last 
VSAN, [chars] VSAN: [dec] 

Explanation    FTA turned off for the Non-Last Vsan

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_TURN_ON: Turn ON FTA, [chars] VSAN: [dec] 

Explanation    FTA turned ON

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_FTA_WARNING: FTA Warning :[chars] 

Explanation    Generic FTA Warning

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_IF_CR_DEL: Interface [chars] [chars] 

Explanation    FCIP Interface was Created or Deleted

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_MODE1_CHANGED_TO_MODE2: Changing mode1 compression to 
mode2 for [chars], on a MSM/SSN-16 linecard 

Explanation    Change mode1 compression to mode2 on a MSM/SSN-16 linecard

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_NUM_TCP_CONNS_MISMATCH: [chars]: configured for 2 tcp 
connections but currently operating with 1 connection

Explanation    Number of configured tcp connections don't match number of connections currently up

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_PEER_CAVIUM: Peer FCIP [chars] is a MSM/SSN-16 linecard 

Explanation    Peer linecard is a MSM/SSN-16

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_PEER_NON_CAVIUM: Peer FCIP [chars] is a non MSM/SSN-16 
linecard 

Explanation    Peer linecard is non MSM/SSN-16

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_RA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape Read 
Acceleration capability with peer

Explanation    The FCIP Tape Read Acceleration capability does not match with peer's configuration

Recommended Action    Fix the FCIP Tape Read Acceleration capability to be consistent with the peer

Error Message     IPS-5-FCIP_SF_NOT_SUPPORTED: Special-Frame not supported for FCIP 
[chars] 

Explanation    Spl-Frame not supported in this release

Recommended Action    Informational no action required

Error Message     IPS-5-FCIP_TA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape 
Acceleration configuration with peer

Explanation    The FCIP Tape Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Tape Acceleration configuration to be consistent with the peer

Error Message     IPS-5-FCIP_TA_ITL_MISMATCH: [chars]: Mismatch in FCIP Write/Tape 
Acceleration software capability with peer

Explanation    The FCIP Write/Tape Acceleration software capability does not match with peer's software capability

Recommended Action    Fix the FCIP software to be consistent with the peer

Error Message     IPS-5-FCIP_TSTAMP_CHK_FAILED: [chars]: Timestamp check failed on 
ingressing frames 

Explanation    Timestamp between local and remote side exceeds the configured tolerance

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_UNBIND_FAILED: UNBIND failed for [chars] due to [chars] 
for [chars] 

Explanation    FCIP/ISCSI Interface UNBIND from Ethernet port failed

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_WA_CFG_MISMATCH: [chars]: Mismatch in FCIP Write 
Acceleration configuration with peer

Explanation    The FCIP Write Acceleration configuration does not match with peer's configuration

Recommended Action    Fix the FCIP Write Acceleration configuration to be consistent with the peer

Error Message     IPS-5-FCIP_WA_XFER_RDY_ERR: [chars]: FCIP Write Acceleration received 
XFER-RDY after exhcange cleanup. Host [hex] Target [hex]

Explanation    FCIP Write/Tape Acceleration received XFER-RDY after exchange cleanup

Recommended Action    No action is required.

Error Message     IPS-5-FCIP_XRCE_CFG_MISMATCH: [chars]: Mismatch in FCIP XRC Emulator 
configuration with peer

Explanation    The FCIP XRC Emulator configuration does not match with peer's configuration

Recommended Action    Fix the FCIP XRC Emulator configuration to be consistent with the peer

Error Message     IPS-5-IPS_IPACL_LOG_MSG: [chars] 

Explanation    Details of the packet dropped due to ACLs

Recommended Action    No action is required.

Error Message     IPS-5-IPS_MGR_FEATURE_ENABLE: ips:[dec] iscsi:[dec] fcip:[dec] 
iscsi-intf-vsan:[dec] ips-lc:[dec] 

Explanation    IPS Manager feature enabled/disabled

Recommended Action    No action is required.

Error Message     IPS-5-IPS_TCP_PORT_IN_USE: Cannot bringup interface [chars], local 
port already in use 

Explanation    FCIP and iSCSI interface are trying to use the same local port, please use different ports

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_BAD_DATA_DIGEST_CRC: iSCSI ingress data digest error from 
initiator [chars] alias [chars] S_ID [hex] to D_ID [hex]

Explanation    ISCSI Ingress Data Digest CRC failed

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_DOWN_BATCH: [chars]: [dec] iSCSI sessions failed in 
last [chars], reason: [chars] 

Explanation    Number of iSCSI session down during the last time interval

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_DOWN: [chars]: iSCSI session down from initiator 
[chars] alias [chars] ip [chars] to target [chars], reason: [chars]

Explanation    ISCSI session goes down

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_CONN_UP: [chars]: iSCSI session up from initiator [chars] 
alias [chars] ip [chars] to target [chars]

Explanation    ISCSI session comes up and reaches Full-Feature phase

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_PORT_FAILOVER: [chars]: iSCSI initiator [chars] alias 
[chars] ip [chars] target [chars]. FC session failed over to port [chars]

Explanation    FC session for the iSCSI session failed over to newly active port

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SB_GET_TGT: iSCSI SB get [dec] targets, initiator [chars] 
alias [chars] ip [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_CREATE_FAILURE: [chars]: iSCSI Session initiator 
[chars] target [chars] create failed. [chars] 

Explanation    ISCSI Session Create failed

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_CREATE_REDIRECT: [chars]: iSCSI Session initiator 
[chars] target [chars] redirected to [chars]/[chars] 

Explanation    ISCSI Session Create redirected

Recommended Action    No action is required.

Error Message     IPS-5-ISCSI_SESSION_REDIRECT_TIMEOUT: iSCSI Session initiator [chars] 
to [chars] redirected to [chars] timeout 

Explanation    ISCSI Session Redirect timeout

Recommended Action    No action is required.

Error Message     IPS-5-ISLB_CFS_SESSION_CLEARED: CFS Session Cleared 

Explanation    CFS Session Cleared by user

Recommended Action    No action is required.

Error Message     IPS-5-PORT_IPCFG_FAILED: Cannot configure IP address for interface 
[chars] 

Explanation    Cannot configure IPS port IP address

Recommended Action    No action is required.

Error Message     IPS-5-SB_MGR_CORE_FAILED: Ethernet Processing core [chars] failed due 
to [chars] 

Explanation    Ethernet Processing Core failed

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_ENTITY_ID_MISMATCH: [chars]: special frame profile ID 
mismatch 

Explanation    Special frame received and destination profile ID does not match local profile ID

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_FABRIC_WWN_MISMATCH: [chars]: special frame fabric wwn 
mismatch 

Explanation    Special frame received and source/destination fabric wwn does not match local destination/ source fabric wwn

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_IF_ADMIN_DOWN: [chars]: special frame received if down 

Explanation    Special frame received and interface is admin down

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_IF_NOT_ENABLED: [chars]: special frame not enabled 

Explanation    Special frame received and interface special frame configuration is disabled

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_INVALID_NONCE: [chars]: special frame response has 
invalid nonce for FCIP

Explanation    Special frame response has a different nonce than was originally sent in the special frame

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_NOT_RECV: [chars]: special frame was not received by 
passive-side FCIP 

Explanation    Special frame was not received by the passive-side of the FCIP TCP tunnel within given time period

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_RESP_MISMATCH: [chars]: special frame response has byte 
mismatch for FCIP

Explanation    Special frame response has a mismiatch in one of the bytes from what was sent from the FCIP special frame sender

Recommended Action    No action is required.

Error Message     IPS-5-SFRAME_RESP_NOT_RECV: [chars]: special frame response was not 
received by active-side FCIP

Explanation    Special frame response was not received by the active-side of the FCIP TCP tunnel within given time period

Recommended Action    No action is required.

IPS-7

Error Message     IPS-7-ISCSI_FCNS_QUERY_REQ: return [hex], wait [dec], VSAN [dec], 
Init: [chars] 

Explanation    ISCSI FCNS query

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_FCNS_QUERY_RESP: result [hex], [dec] targets, wait [dec], 
Init: [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_NEW_FCNS_QUERY_REQ: return [hex], VSANs [chars], Init: 
[chars] 

Explanation    ISCSI FCNS query

Recommended Action    No action is required.

Error Message     IPS-7-ISCSI_NEW_FCNS_QUERY_RESP: result [hex], [dec] entries, [dec] 
targets, [dec] total targets Init: [chars] 

Explanation    ISCSI FCNS query response

Recommended Action    No action is required.

Error Message     IPS-7-ISNS_SVR_ERR_RESPONSE: iSNS server returned following error 
code on iSNS request for interface [chars] : [dec]

Explanation    ISNS server returned an error for register/deregister request. For select error codes iSNS client would retry and re-register all target nodes corresponding to the interface

Recommended Action    No action is required.

IPV6 Messages

This section contains the IPV6 messages.

IPV6-2

Error Message    IPV6-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The IP Configuration Manager failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IPV6-3

Error Message     IPV6-3-FILE_WRITE_FAILED: Writing to file [chars] failed - error: 
[chars] 

Explanation    Writing to a file failed probably due to no space.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     IPV6-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

IPV6-4

Error Message     IPV6-4-DAD_FAILED_EVENT: Duplicate address detection failed for 
[chars] on [chars] 

Explanation    Duplicate address detection for IP address failed.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

IPV6-6

Error Message     IPV6-6-CONFIG_EVENT: IP Configuration Msg: [chars] 

Explanation    Configuration message that needs to be logged.

Recommended Action    No action is required.

Error Message     IPV6-6-INTERFACE_DELETED: The interface [chars] has been deleted 

Explanation    The specified interface has been deleted. The service will delete all the configuration on that interface.

Recommended Action    No action is required.

Error Message     IPV6-6-INTERFACE_EVENT: IP address [chars] [chars] on interface 
[chars] 

Explanation    The IP address [chars] has been successfully [chars] on the interface [chars].

Recommended Action    No action is required.

Error Message     IPV6-6-ROUTE_NOT_ACTIVE: The [chars] is not active 

Explanation    The specified route is successfully configured but currently is not active.

Recommended Action    Check that the route is correct and the outgoing interface is operationally up.

Error Message     IPV6-6-STARTING: IP configuration Manager started 

Explanation    The IP Configuration Manager service has successfully started.

Recommended Action    No action is required.

IP Messages

This section contains the IP messages.

IP-2

Error Message    IP-2-ALLOC_MEMORY: Memory allocation failed 

Explanation    The IP Configuration Manager failed to allocate a block of dynamic memory.

Recommended Action    No action is required.

IP-3

Error Message     IP-3-FILE_WRITE_FAILED: Writing to file [chars] failed - error: 
[chars] 

Explanation    Writing to a file failed probably due to no space.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

Error Message     IP-3-INIT_FAILED: Initialization failed. Component [chars] 

Explanation    The service failed to start. The failure occurred while initializing the component [chars].

Recommended Action    Show processes to check the status of the other processes, debug the specified component.

IP-4

Error Message     IP-4-DAD_FAILED_EVENT: Duplicate address detected for [chars] on 
[chars] 

Explanation    Duplicate address detected for IP address.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

IP-6

Error Message     IP-6-CONFIG_EVENT: IP Configuration Msg: [chars] 

Explanation    Configuration message that needs to be logged.

Recommended Action    No action is required.

Error Message     IP-6-INTERFACE_DELETED: The interface [chars] has been deleted 

Explanation    The specified interface has been deleted. The service will delete all the configuration on that interface.

Recommended Action    No action is required.

Error Message     IP-6-INTERFACE_EVENT: IP address [chars] [chars] on interface [chars] 

Explanation    The IP address [chars] has been successfully [chars] on the interface [chars].

Recommended Action    No action is required.

Error Message     IP-6-ROUTE_NOT_ACTIVE: The [chars] is not active 

Explanation    The specified route is successfully configured but currently is not active.

Recommended Action    Check that the route is correct and the outgoing interface is operationally up.

Error Message     IP-6-STARTING: IP configuration Manager started 

Explanation    The IP Configuration Manager service has successfully started.

Recommended Action    No action is required.

ISAPI Messages

This section contains the ISAPI messages.

ISAPI-SLOT#-0

Error Message    ISAPI-SLOT#-0-INVISTA_EMERG: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-MSM_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-NSP_EMERG: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-SSM_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-0-SSN_EMERG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-1

Error Message     ISAPI-SLOT#-1-INVISTA_ALERT: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-MSM_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-NSP_ALERT: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-SSM_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-1-SSN_ALERT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-2

Error Message     ISAPI-SLOT#-2-INVISTA_CRIT: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-MSM_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-NSP_CRIT: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-SSM_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-2-SSN_CRIT: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-3

Error Message     ISAPI-SLOT#-3-INVISTA_ERROR: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-MSM_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-NSP_ERROR: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-SSM_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-3-SSN_ERROR: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-4

Error Message     ISAPI-SLOT#-4-INVISTA_WARN: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-MSM_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-NSP_WARN: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-SSM_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-4-SSN_WARN: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-5

Error Message     ISAPI-SLOT#-5-INVISTA_NOTICE: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-MSM_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-NSP_NOTICE: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-SSM_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-5-SSN_NOTICE: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-6

Error Message     ISAPI-SLOT#-6-INVISTA_INFO: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-MSM_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-NSP_INFO: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-SSM_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-6-SSN_INFO: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISAPI-SLOT#-7

Error Message     ISAPI-SLOT#-7-INVISTA_DEBUG: [chars] 

Explanation    Isapi-invista software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-MSM_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-NSP_DEBUG: [chars] 

Explanation    Isapi-nsp software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-SSM_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

Error Message     ISAPI-SLOT#-7-SSN_DEBUG: [chars] 

Explanation    Isapi software messages

Recommended Action    No action is required.

ISNS Messages

This section contains the ISNS messages.

ISNS-2

Error Message    ISNS-2-ISNS_CFS_OPERATION_FAILED: iSNS CFS [chars] failed 

Explanation    ISNS CFS operation failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     ISNS-2-ISNS_INIT: iSNS initialization of [chars] [chars] 

Explanation    ISNS initialization failed

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

IVR Messages

This section contains the IVR messages.

IVR-2

Error Message    IVR-2-AUTOLEARN_ACTION_FAIL: failure happens during constructing 
virtual dynamic pfcid table

Explanation    This can happen if failure happens during building, distributing or committing the virtual dynamic pfcid table

Recommended Action    Please 1. check the fabric connection or 2. check current virtual user-configured pfcid entries and internally assigned virtual fcid entries for possible conflict

Error Message     IVR-2-AUTOLEARN_FEATURE_NOT_SUPPORT: some switches:[chars] don't 
support autolearn 

Explanation    This can happen if some switches doesn't support the virtual pfcid autolearn feature

Recommended Action    Please upgrade the unsupported switches

Error Message     IVR-2-CFS_PEER_LOST_WITHIN_SESSION: CFS peer with switch wwn [chars] 
was lost in the middle of an active CFS session. Abort the CFS session and re-enter 
the configuration changes

Explanation    Due to port flaps, link outages, switch restart etc. a CFS peer switch of IVR was lost. The current configuration changes would not be applied to this peer until the peer merges with this switch. The CFS merge may fail if the configuration at the lost peer conflicts with the changes made in this session. Also, IVR auto topology could be out of sync. with this peer. It is recommended that the user abort this CFS session using ivr abort command and then re-enter the configuration changes.

Recommended Action    No action is required.

Error Message     IVR-2-DEVICE_FCID_REWRITE_FAILURE: Failure while programming FCID 
rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able 
to communicate with its peer devices, failure reason code: [hex]

Explanation    Failed to program FCID rewrite entries probably because the hardware ran out of FCID rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology

Recommended Action    Reduce the number of devices involved in IVR in the active IVR zoneset. Also, reduce the number of redundant transit VSANs, if any

Error Message     IVR-2-DEVICE_STATE_INCOMPATIBLE_WITH_NAT_MODE: State for device with 
port WWN [chars] could not be restored because it was incompatible with the current 
NAT mode([dec]). This probably happened because NAT mode was modified without 
completely deactivating the active IVR zoneset

Explanation    This probably happened because NAT mode was modified without completely deactivating the active IVR zoneset

Recommended Action    The switch needs to be rebooted

Error Message     IVR-2-DEVICE_VSAN_REWRITE_FAILURE: Failure while programming VSAN 
rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able 
to communicate with its peer devices

Explanation    Failed to program VSAN rewrite entries probably because the hardware ran out of VSAN rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology

Recommended Action    Reduce the number of domains involved in IVR by moving the members of active IVR zoneset to fewer switches. Also, reduce the number of redundant transit VSANs, if any

Error Message     IVR-2-INTEROP_MODE_2_OR_3_BF_FAILED: [chars] VSAN [dec] Virtual 
Domain [chars] 

Explanation    Build Fabric (BF) failed in VSAN [dec]. The BF was initiated in order to remove an unused virtual domain [dec] from the fcdomain list in that VSAN. The virtual domain still remains in the fcdomain list and hence it would not be available in that VSAN for assignment.

Recommended Action    Perform a manual build fabric using fcdomain's interface if you would like to remove the unused virtual domain(s) from the fcdomain list.

Error Message     IVR-2-INTEROP_MODE_2_OR_3_RDI_FAILED: VSAN [dec], requested domain 
[chars], received domain [chars] sWWN [chars]. Return Code [chars]

Explanation    Request Domain Identifier (RDI) command to allocate virtual domain [dec] failed in VSAN [dec]. Received another domain [chars] instead. IVR-members connected to third-party switch may not participate in IVR communications. It is likely that the domain requested in the RDI command is already in use.

Recommended Action    Reassign the domains so that the domain requested via RDI does not overlap with any existing domain in that VSAN.

Error Message     IVR-2-IVR_DISABLE_FAILED: Inter-VSAN Routing disable failed for 
reason: [chars] 

Explanation    Inter-VSAN Routing disable failed for reason: [chars]. Cleanup might not have completed

Recommended Action    Deactivate ivr zoneset and disable ivr again. If that fails, then the ivr process would terminate itself in 5 minutes

Error Message     IVR-2-IVZS_ACTIVATION_FAILED_RETRYING: Inter-VSAN zoneset activation 
failed in VSAN [dec] : [chars]. retrying after [dec] seconds

Explanation    Inter-VSAN zoneset activation failed in VSAN [dec] : [chars]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.

Recommended Action    No action is required.

Error Message     IVR-2-NO_LICENSE_SHUTDOWN: Inter-VSAN Routing is shutting down. 

Explanation    License required for continued IVR operation is not available. Hence IVR is shutting down

Recommended Action    Install appropriate license for IVR services and then enable IVR again.

Error Message     IVR-2-NO_LICENSE_WARNING: Inter-VSAN Routing would shutdown in [dec] 
seconds. 

Explanation    License required for continued IVR operation is not available. Unless the required license is installed IVR would shutdown in [dec] seconds. IVR configurations would be lost.

Recommended Action    Install appropriate license for IVR services to continute to operate uninterrupted within [dec] seconds

Error Message     IVR-2-PERSISTENT_VIRTUAL_FCID_CONFLICT_WITH_AUTOLEARN: Persistent 
virtual fcid and dynamic pfcid entries 

Explanation    This can happen if conflict happens during persistent virtual domain, or virtual fcid entry configuration.

Recommended Action    Please assign a non-conflict persistent virtual domain or fcid entry with current dynamic entries

Error Message     IVR-2-PERSISTENT_VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the 
configured persistent virtual domain/fcid could not be assigned

Explanation    This can happen if the virtual domain/fcid configured by the user is - a) Already in use (either by IVR or a real switch) b) Not allowed due to interop mode or allowed domain list

Recommended Action    Please make sure that the configured virtual domain/fcid is allowed and available for use

Error Message     IVR-2-VIRTUAL_DOMAIN_CONFLICT: In VSAN [dec] virtual domain [dec] 
from native VSAN [dec] conflicts with native VSAN [dec] for the same virtual domain

Explanation    Currently advertised virtual domain [dec] in VSAN [dec] is native to VSAN [dec]. This switch has learned of a device that is member of active IVR zone and has the same domain ID, but belongs to a different native VSAN. This device would not be advertised in that VSAN until the domain conflict is resolved.

Recommended Action    No action is required.

Error Message     IVR-2-VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the internally 
generated FCID conflicts with fcid assigned to WWN [chars]. Please configure fcid 
for WWN [chars] too

Explanation    This can happen if the virtual domain/fcid internally configured is already in use by another active device

Recommended Action    Please assign a different persistent virtual fcid by CLI command

IVR-3

Error Message     IVR-3-AAM_MODE_CANNOT_CHANGE: AAM mode cannot be changed. Might cause 
the fabric NAT mode inconsistency

Explanation    Could be caused by ivr NAT is not enable

Recommended Action    No action is required.

Error Message     IVR-3-ACL_ERROR: ACL API, [chars], failed with error [chars] 

Explanation    IVR invoked ACL API and received the error code. [chars] describes the API and [chars] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-ACL_PERMIT_ENTRY_ERROR: ACL permit entry update on interface 
[chars] failed for reason: [chars] 

Explanation    ACL could not program permit entries for IVR traffic. [chars] describes the interface named and [chars] describes the system error message from ACL. IVR traffic coming from the interface may be dropped.

Recommended Action    If the problem persists, please contact TAC, or your reseller for support.

Error Message     IVR-3-ACL_PLOGI_ENTRY_ERROR: PLOGI capture entry update in slot [dec] 
failed for reason: [chars] 

Explanation    ACL could not program IVR PLOGI could not be programmed. slot[dec] describes the line card slot number and [chars] describes the system error message. PLOGI and its response may be dropped because ivr process cannot capture those frames.

Recommended Action    No action is required.

Error Message     IVR-3-AFID_CONFLICT: [chars] 

Explanation    AFID configuration is different at different ivr-enabled switches in the same VSAN. Change AFID configuration (auto mode) or vsan topology configuration (user mode) to make it consistent

Recommended Action    No action is required.

Error Message     IVR-3-CFS_INVALID_PAYLOAD_RECEIVED: Inter-VSAN process received 
invalid payload from CFS 

Explanation    Inter-VSAN process received invalid payload from CFS.

Recommended Action    No action is required.

Error Message     IVR-3-CLEAR_FAILED: [chars] 

Explanation    An error occurred while clearing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_FAILED: [chars] 

Explanation    An error occurred while committing configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_PARTIALLY_FAILED: [chars] 

Explanation    An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-COMMIT_REJECTED: [chars] 

Explanation    Commit request received from remote switch is rejected. The reason for the failure: [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-DDAS_LOCK_TIMER_EXPIRED: IVR database lock is released, as 
device-alias commit/abort notification is not received in the expected time frame.

Explanation    When device-alias sends the validation request, IVR database is locked and a timer is started. For any reason, if device-alias commit/abort notification is not received within the expected time frame, the lock timer gets expired and the lock is released. If device-alias commmit notification is received after the lock is released, the changes are not applied and this could cause inconsistency between IVR and device-alias.

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_NOT_PREENT_IN_FB_DB_FICON: Device with port WWN [chars] 
could not be exported to VSANs [chars] because its native switch is not present 
in the current active fabric binding database of those VSANs.

Explanation    This happens if ficon is enabled on VSANs [chars] and native switch of device with port WWN [chars] is not present in the current active fabric binding database of those VSANs. This is a requirement for ficon compliance.

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_ON_WRONG_NATIVE_AFID_VSAN: Device with port WWN [chars] 
(FCID:[chars], native VSAN [dec] native AFID [dec]) may not be exported to other 
VSANs (for Inter-VSAN zoning) because it has come online in VSAN [dec] AFID [dec]

Explanation    Device has come online on a AFID/VSAN different from the configured native AFID/VSAN

Recommended Action    No action is required.

Error Message     IVR-3-DEVICE_ON_WRONG_NATIVE_VSAN: Device with port WWN [chars] 
(FCID:[chars], native VSAN [dec]) may not be exported to other VSANs (for 
Inter-VSAN zoning) because domain [hex] exists in VSAN [dec]

Explanation    Device has come online on a VSAN different from the configured native VSAN or the device does not satisfy unique domain criteria.

Recommended Action    No action is required.

Error Message     IVR-3-DM_ERROR: Domain Manager API, [chars], failed with error [hex] 

Explanation    IVR invoked DM API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-DOMAIN_DISALLOWED_IN_INTEROP: Device with port WWN [chars] and 
FCID [chars] may not be able to participate in Inter-VSAN zone since domain [dec] 
is disallowed in the interop mode for VSAN [dec]

Explanation    VSAN interop modes place restrictions on what domain ranges are allowed. This domain is out of the range allowed for this interop mode. See the Cisco MDS 9000 Family Configuration Guide for details on the domain range limitations.

Recommended Action    Change the domain of the switch to which this IVR zone member is connected to so that it is within the allowed domain list for the interop mode. The domain identifier can be statically assigned using fcdomain interface. You can also configure a range of domains allowed in a VSAN using the fcdomain's 'allowed-domains' interface.

Error Message     IVR-3-DOMAIN_UNAVAILABLE: Device with port WWN [chars] and FCID 
[chars] may not be able to participate in Inter-VSAN zone since domain [dec] is 
already assigned in VSAN [dec]

Explanation    Device with port WWN [chars] and FCID [dec] may not be able to participate in Inter-VSAN zone since domain [dec] is already assigned in VSAN [dec].

Recommended Action    No action is required.

Error Message     IVR-3-FC2_ERROR: FC2 API [chars] failed with error [hex] for [chars] 

Explanation    IVR invoked FC2 API for [chars] socket and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-FCID_NAT_MODE_CANNOT_CHANGE: IVR NAT mode cannot be changed. 
Might cause the fabric NAT mode inconsistency

Explanation    Could be caused by active zoneset, pending activation /deactivation or non-empty device list

Recommended Action    No action is required.

Error Message     IVR-3-FCID_REWRITE_REQUEST_TO_ACL_FAILED: fcid rewrite [chars] 
request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]). 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-INTERNAL_ERROR: Internal error: [chars] 

Explanation    IVR process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.

Recommended Action    No action is required.

Error Message     IVR-3-INVALID_ZONE_MEMBER_PROP_INTEROP_MODE_2_3: unsupported 
member/zone properties in interop mode 2 or 3 [chars] 

Explanation    Inter-VSAN member properties incompatible with interop mode vsan

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_ACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] 
activation failed in VSAN [dec] 

Explanation    Inter-VSAN zoneset activation failed failed in VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_ACTIVATION_FAILED: Inter-VSAN zoneset [chars] activation 
failed 

Explanation    Inter-VSAN zoneset activation failed.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_DEACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] 
deactivation failed in VSAN [dec] 

Explanation    Inter-VSAN zoneset deactivation failed in VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-IVZ_DEACTIVATION_FAILED: Inter-VSAN zoneset [chars] 
deactivation failed 

Explanation    Inter-VSAN zoneset deactivation failed.

Recommended Action    No action is required.

Error Message     IVR-3-LOCK_FAILED: [chars] 

Explanation    An error occurred while acquiring the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MERGE_ACTIVATION_FAILED: [chars] 

Explanation    An error occurred while activating merged configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MERGE_FAILED: reason is [chars] 

Explanation    An error occurred while merging configuration. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-MTS_ERROR: MTS message transmission failed with error [dec] 

Explanation    IVR process unsuccessfully tried to send a MTS message. MTS error number is specified in [dec].

Recommended Action    No action is required.

Error Message     IVR-3-NS_ERROR: FCNS API, [chars], failed with error [hex] 

Explanation    IVR invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] 
failed with error [hex] 

Explanation    IVR read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_ERROR: PSS operation [chars] returned error: [hex] 

Explanation    [chars] specifies the context where the failure occurred and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for 
[chars] failed with error [hex] 

Explanation    IVR read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code.

Recommended Action    No action is required.

Error Message     IVR-3-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED: qos iod undrop request 
vsan [dec] did [chars] failed:[chars]. 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-RIB_ERROR: RIB API, [chars], failed with error [hex] 

Explanation    IVR invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error.

Recommended Action    No action is required.

Error Message     IVR-3-ROUTE_REQUEST_TO_ACL_FAILED: route [chars] request vsan [dec] 
domain [dec] failed:[chars]. 

Explanation    This happens when either after IVR retried the request few times or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-3-TOPOLOGY_COMPUTATION_FAILED: Inter-VSAN Topology computation 
has failed due to: [chars] 

Explanation    Inter-VSAN Topology has failed due to [chars]. Possible reasons are (a) Number of AFID/VSAN combination is more than te maximum supported value of 128, or (b) Number of ivr-enabled switches is more than the maximum supported value of 128

Recommended Action    No action is required.

Error Message     IVR-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is 
received 

Explanation    IVR process received unexpected MTS event. MTS opcode is specified in [dec].

Recommended Action    No action is required.

Error Message     IVR-3-UNLOCK_FAILED: [chars] 

Explanation    An error occurred while releasing the lock. The reason for the failure : [chars]

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-VSAN_SEGMENTED: [chars] 

Explanation    VSAN is segmented. VSAN is removed from the topology graph and hence no Inter-VSAN traffic can flow through this VSAN.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     IVR-3-ZS_POLICY_IS_DENY_NO_ACTIVE_ZS: Default zone behavior policy is 
deny on VSAN [dec] and there is no active zoneset

Explanation    Default zone behavior is deny and there is no active zoneset. Inter-VSAN zone members may not be able communicate in this VSAN.

Recommended Action    No action is required.

Error Message     IVR-3-ZS_POLICY_IS_PERMIT_NO_FORCE: Default zone behavior policy is 
permit on VSAN [dec] and the force option is off

Explanation    Default zone behavior is permit and the force option is off. Inter-VSAN zoneset activation on this VSAN has failed.

Recommended Action    No action is required.

Error Message     IVR-3-ZS_POLICY_IS_PERMIT_ZS_DEACTIVATED: Default zone behavior 
policy is permit on VSAN [dec] and regular zoneset deactivated

Explanation    Default zone behavior is permit and regular zoneset is deactivated. Inter-VSAN zone members may not be able to communicate.

Recommended Action    No action is required.

IVR-4

Error Message     IVR-4-AUTO_TOPOLOGY_UPDATE_DISCARDED: [chars] 

Explanation    Received auto topology update is discarded due to conflicts

Recommended Action    No action is required.

Error Message     IVR-4-FCID_REWRITE_REQUEST_TO_ACL_FAILED_AND_RETRYING: fcid rewrite 
[chars] request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]). Retrying 
the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-PERSISTENT_VIRTUAL_DOMAIN_MERGE_CONFLICT: [chars] 

Explanation    Merge failed due to conflict in the persistent virtual domain configuration

Recommended Action    No action is required.

Error Message     IVR-4-PERSISTENT_VIRTUAL_FCID_MERGE_CONFLICT: [chars] 

Explanation    Merge failed due to conflict in the persistent virtual fcid configuration

Recommended Action    No action is required.

Error Message     IVR-4-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED_AND_RETRYING: qos iod 
undrop request vsan [dec] did [chars] failed:[chars]. Retrying the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-ROUTE_REQUEST_TO_ACL_FAILED_AND_RETRYING: route [chars] 
request vsan [dec] domain [dec] failed:[chars]. Retrying the request again. 

Explanation    This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.

Recommended Action    No action is required.

Error Message     IVR-4-UNKNOWN_NATIVE_VSAN: Unknown native VSAN for the virtual domain 
[dec] in VSAN [dec] local native VSAN for the same virtual domain is [dec]

Explanation    Could not determine native VSAN of the currently advertised virtual domain [dec] in VSAN [dec]. This switch has learned of a device that is member of active IVR zone has the same domain ID, and belongs to native VSAN [dec]. This device would not be advertised in that VSAN until the native VSAN information is resolved.

Recommended Action    No action is required.

IVR-5

Error Message     IVR-5-AAM_MODE_DEREGISTERED_FAILED: Abstract ACL Manager (AAM) mode 
deregister failed 

Explanation    Abstract ACL Manager (AAM) mode deregister failed

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_DEREGISTERED: Abstract ACL Manager (AAM) mode has been 
deregistered 

Explanation    Abstract ACL Manager (AAM) mode has been deregistered

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_REGISTERED_FAILED: Abstract ACL Manager (AAM) register 
failed 

Explanation    Abstract ACL Manager (AAM) register failed

Recommended Action    No action is required.

Error Message     IVR-5-AAM_MODE_REGISTERED: Abstract ACL Manager (AAM) mode has been 
registered 

Explanation    Abstract ACL Manager (AAM) mode has been registered

Recommended Action    No action is required.

Error Message     IVR-5-FCID_NAT_MODE_ACTIVATED: FCID network address translation (NAT) 
mode has been activated 

Explanation    FCID network address translation (NAT) mode has been activated

Recommended Action    No action is required.

Error Message     IVR-5-FCID_NAT_MODE_DEACTIVATED: FCID network address translation 
(NAT) mode has been deactivated 

Explanation    FCID network address translation (NAT) mode has been deactivated

Recommended Action    No action is required.

Error Message     IVR-5-IVR_ASSERTION_FAILED: Unexpected assertion failure in File 
[chars] at Line [dec] 

Explanation    An assertion failed in IVR code

Recommended Action    No action is required.

Error Message     IVR-5-IVZS_ACTIVATION_RETRYING: Inter-VSAN zoneset activation did not 
go through because of [chars], retrying in VSAN [dec] after [dec] seconds

Explanation    Inter-VSAN zoneset activation failed because of [chars] in VSAN [dec]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.

Recommended Action    No action is required.

Error Message     IVR-5-IVZS_WAITING_FOR_LOWEST_SWWN: Waiting for lowest switch WWN 
Inter-VSAN enabled switch in VSAN [dec] 

Explanation    Only lowest switch WWN Inter-VSAN enabled switch adds the Inter-VSAN zones to the regular active zoneset in a VSAN. This local switch is not the lowest sWWN switch in VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_ACTIVATED_VSAN: Inter-VSAN zoneset [chars] activated in 
VSAN [dec] 

Explanation    Inter-VSAN zoneset activated in VSAN[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_ACTIVATED: Inter-VSAN zoneset [chars] activated 

Explanation    Inter-VSAN zoneset activated[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_CLEANUP_DONE_BY_TIMER: Inter-VSAN clean-up is not done 
after waiting for 5 minutes 

Explanation    Inter-VSAN related configuration might not be cleaned up before the ivr process is terminated

Recommended Action    If the problem persists, you may have to reboot your switch to clean up the old IVR configuration

Error Message     IVR-5-IVZ_CLEANUP_DONE: Inter-VSAN clean-up is done 

Explanation    Inter-VSAN related configuration is cleaned up before exiting.

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_DEACTIVATED_VSAN: Inter-VSAN zoneset [chars] deactivated in 
VSAN [dec] 

Explanation    Inter-VSAN zoneset deactivated in VSAN[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_DEACTIVATED: Inter-VSAN zoneset [chars] deactivated 

Explanation    Inter-VSAN zoneset deactivated[dec].

Recommended Action    No action is required.

Error Message     IVR-5-IVZ_PARTIALLY_ACTIVATED: Inter-VSAN zoneset [chars] partially 
activated 

Explanation    Inter-VSAN zoneset activated[dec].

Recommended Action    Check if it is successful in all VSANs by doing show IVR zoneset status.

Error Message     IVR-5-IVZ_PARTIALLY_DEACTIVATED: Inter-VSAN zoneset [chars] partially 
deactivated 

Explanation    Inter-VSAN zoneset deactivated[dec].

Recommended Action    Check if it is successful in all VSANs by doing show IVR zoneset status.

Error Message     IVR-5-LICENSE_CHECKIN_FAILED: Failed to checkin [chars] license: 
Err=[chars] 

Explanation    Failed to checkin [chars] license

Recommended Action    No action is required.

Error Message     IVR-5-SERVICE_GROUP_ACTIVATED: Inter-VSAN Service Group has been 
activated 

Explanation    Inter-VSAN Service Group has been activated.

Recommended Action    No action is required.

Error Message     IVR-5-SERVICE_GROUP_DEACTIVATED: Inter-VSAN Service Group has been 
deactivated 

Explanation    Inter-VSAN Service Group has been deactivated.

Recommended Action    No action is required.

Error Message     IVR-5-VSAN_NO_LONGER_SEGMENTED: [chars] 

Explanation    VSAN is no longer segmented. VSAN is added back to the topology graph and hence Inter-VSAN traffic can now flow through this VSAN.

Recommended Action    No action is required.

Error Message     IVR-5-VSAN_TOPOLOGY_ACTIVATED: Inter-VSAN Topology has been activated 

Explanation    Inter-VSAN Topology has been activated.

Recommended Action    No action is required.

IVR-6

Error Message     IVR-6-DRAV_ASYNC_DOMAIN_RELEASE: [chars] 

Explanation    DRAV FSM has unconditionally released a domain due to conflict after a fabric merge. The details are in [chars]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_CRITICAL_RETRY_EXCEED: [chars] 

Explanation    DRAV FSM frames are attempted to be resent. The details are in [chars]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_DOMAIN_ALLOC: Virtual domain [dec] for Native AFID: [dec] 
Native VSAN [dec] 

Explanation    A virtual domain indicated by [dec] has been reserved for a device with native AFID [dec] and native VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_DOMAIN_RELEASE: Virtual domain [dec] for Native AFID: 
[dec] Native VSAN [dec] 

Explanation    A virtual domain indicated by [dec] has been released used by devices with native AFID [dec] and native VSAN [dec]

Recommended Action    No action is required.

Error Message     IVR-6-DRAV_TOPO_UPDATE: [chars] 

Explanation    DRAV FSM Topology has been updated as indicated by [chars]

Recommended Action    No action is required.

Error Message     IVR-6-LICENSE_VALID: A valid license for Inter-VSAN Routing has been 
obtained 

Explanation    A valid license for Inter-VSAN Routing has been obtained

Recommended Action    No action is required.

IVR-7

Error Message     IVR-7-CFS_REQ_RCVD: [chars] 

Explanation    CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.

Recommended Action    No action is required.

Error Message     IVR-7-CFS_RESP_SENT: [chars] 

Explanation    CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message

Recommended Action    No action is required.

L2FMC Messages

This section contains the L2FMC messages.

L2FMC-SLOT#-0

Error Message    L2FMC-SLOT#-0-L2FMC_CLI_INIT_FAILED: CLI library initialization 
failed! 

Explanation    L2FMC failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-0-L2FMC_TIMER_INIT_FAILED: Timer subsystem 
initialization failed! 

Explanation    L2FMC failed to initialize timer library. This is a fatal error.

Recommended Action    No action is required.

L2FMC-SLOT#-2

Error Message     L2FMC-SLOT#-2-L2FMC_MEM_ALLOC: Memory allocation failed. [chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-2-L2FMC_VLAN_NOT_FOUND: VLAN [dec] not found in L2FMC 
database! 

Explanation    L2FMC failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.

Recommended Action    No action is required.

L2FMC-SLOT#-5

Error Message     L2FMC-SLOT#-5-L2FMC_GLBL_AGE_CONFIG_FAIL: Global age value 
configuration to [dec] seconds failed! 

Explanation    L2FMC failed to configure global default age to [dec] seconds.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-5-L2FMC_VLAN_AGE_CONFIG_FAIL: VLAN Age configuration to 
[dec] seconds failed! 

Explanation    L2FMC failed to configure age for VLAN [dec] to [dec] seconds.

Recommended Action    No action is required.

L2FMC-SLOT#-6

Error Message     L2FMC-SLOT#-6-L2FMC_GLBL_AGE_CONFIGURED: Global age value configured 
to [dec] seconds. 

Explanation    L2FMC has successfully configured global default age to [dec] seconds.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_INITIALIZED: Internal state created [chars] 

Explanation    L2FMC has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_CREATED: VDC [dec] created 

Explanation    Request to create VDC [dec] in L2FMC was successful.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_REMOVED: VDC [dec] Removed 

Explanation    L2FMC has successfully removed VDC [dec] from its databases.

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_VLAN_CREATED: VLAN [dec] created 

Explanation    L2FMC has added VLAN [dec].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC 
[dec] 

Explanation    L2FMC has successfully removed VLAN [dec] from VDC [dec].

Recommended Action    No action is required.

Error Message     L2FMC-SLOT#-6-L2FMC_VLAN_AGE_CONFIGURED: Age configured for VLAN 
[dec] to [dec] seconds. 

Explanation    L2FMC has successfully configured age for VLAN [dec] to [dec] seconds.

Recommended Action    No action is required.

L2FM Messages

This section contains the L2FM messages.

L2FM-0

Error Message    L2FM-0-L2FM_CLI_INITIALIZATION_FAILED: CLI library initialization 
failed! 

Explanation    Failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2FM-0-L2FM_VDC_GWMAC_GET_FAILED: Failed to get gwmac for VDC 

Explanation    Failed to get gwmac for VDC.

Recommended Action    No action is required.

Error Message     L2FM-0-L2FM_WRITE_TO_PSS_FAILED_IN_PREVIOUS_INCARNATION: PSS Write 
Failed in pervious incarnation. Stateful restart not possible 

Explanation    PSS Write Failed in pervious incarnation. Stateful restart not possible

Recommended Action    No action is required.

L2FM-1

Error Message     L2FM-1-L2FM_SMAC_DUP_FOUND: Duplicate static mac found in secondary 
vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars] 

Explanation    Duplicate static mac found in secondary vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars]

Recommended Action    No action is required.

Error Message     L2FM-1-L2FM_WRITE_TO_PSS_FAILED: Failed to write to PSS err [chars] 

Explanation    Failed to write to PSS err [chars]

Recommended Action    No action is required.

L2FM-2

Error Message     L2FM-2-L2FM_AGING_TIME_SET_FAILED: Failed to set age time [dec] for 
vlan [dec] 

Explanation    Failed to set age time [dec] for vlan [dec].

Recommended Action    No action is required.

Error Message     L2FM-2-L2FM_GLBL_AGING_TIME_SET_FAILED: Failed to set global age time 
[dec] 

Explanation    Failed to set global age time [dec]

Recommended Action    No action is required.

Error Message     L2FM-2-L2FM_SMAC_INS_FAILED: Failed to insert static mac for 
VLAN:[dec] MAC:[chars] IfIndex:[hex] Slot:[dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

L2FM-6

Error Message     L2FM-6-L2FM_MTS_SEND_FAILED: Failed to send MTS message errno [hex] 
opcode [dec]

Explanation    No action is required.

Recommended Action    Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.

L2MCAST Messages

This section contains the L2MCAST messages.

L2MCAST-SLOT#-0

Error Message    L2MCAST-SLOT#-0-L2MCAST_CLI_INIT_FAILED: CLI library initialization 
failed! 

Explanation    L2MCAST failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-0-L2MCAST_TIMER_INIT_FAILED: Timer subsystem 
initialization failed! 

Explanation    L2MCAST failed to initialize timer library. This is a fatal error.

Recommended Action    No action is required.

L2MCAST-SLOT#-2

Error Message     L2MCAST-SLOT#-2-L2MCAST_VLAN_NOT_FOUND: VLAN [dec] not found in 
L2MCAST database! 

Explanation    L2MCAST failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-2-L2MCAST: Memory allocation failed. [chars] 

Explanation    Memory allocation failed. This is a critical failure

Recommended Action    No action is required.

L2MCAST-SLOT#-6

Error Message     L2MCAST-SLOT#-6-L2MCAST_HW_INSTALL_FAIL: Hw install failed for vlan 
[dec] ([dec], [chars], [chars]) entry! 

Explanation    L2MCAST failed to insert bd, g, s entry in hardware. Igmp snooping may not be effective on vlan for that group and source

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_INITIALIZED: Internal state created [chars] 

Explanation    L2MCAST has created its internal state stateless/stateful [chars].

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_CREATED: VDC [dec] created 

Explanation    Request to create VDC [dec] in L2MCAST was successful.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_REMOVED: VDC [dec] Removed 

Explanation    L2MCAST has successfully removed VDC [dec] from its databases.

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_CREATED: VLAN [dec] created 

Explanation    L2MCAST has added VLAN [dec].

Recommended Action    No action is required.

Error Message     L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC 
[dec] 

Explanation    L2MCAST has successfully removed VLAN [dec] from VDC [dec].

Recommended Action    No action is required.

LACP Messages

This section contains the LACP messages.

LACP-3

Error Message    LACP-3-GENERAL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     LACP-3-LACP_MEM_PC_MISCFG: LACP misconfiguration detected on [chars]: 
([chars] [dec]-[dec][chars] [dec]-[dec]) 

Explanation    There was an LACP misconfiguration

Recommended Action    No action is required.

Error Message     LACP-3-LACP_MISCFG: LACP misconfiguration detected on [chars]: 
([chars]) 

Explanation    There was an LACP misconfiguration

Recommended Action    No action is required.

Error Message     LACP-3-LACP_SUSPEND_HALF_DUPLEX_PORT: Port [chars] is in half duplex 
mode. suspend port 

Explanation    LACP is not supported in half duplex mode. Suspend port

Recommended Action    No action is required.

Error Message     LACP-3-LACP_UPGRADE_READY_FAILED: Upgrade ready was returned failure. 

Explanation    Upgrade ready event was returned failure since one of the ports in port channels were found to be in intermediate state.

Recommended Action    No action is required.

Error Message     LACP-3-PACKET_TRANSMIT_ERR: [chars]: Could not send LACP packet 
err=[dec] 

Explanation    There was an error in sending LACP packet

Recommended Action    No action is required.

Error Message     LACP-3-SYN_COLL_DIS_EN: [chars] [[chars]]: SYNC, COLLECT and 
DISTRIBUTE flags enabled too early by partner 

Explanation    Potential interop issue. Partner system seems to have enabled sync as well collecting or distributing flags too early even before actor has selected an aggregator

Recommended Action    No action is required.

Error Message     LACP-3-SYSTEM_MAC_ERR: [chars]: Could not get system mac[[chars]] 

Explanation    There was an error in acquiring system mac from VDC Mgr

Recommended Action    No action is required.

LACP-5

Error Message     LACP-5-LACP_DISABLED: LACP Disabled 

Explanation    LACP Service Disabled

Recommended Action    No action is required.

Error Message     LACP-5-LACP_ENABLED: LACP Enabled 

Explanation    LACP Service Enabled

Recommended Action    No action is required.

Error Message     LACP-5-LACP_REMOTE_NOTIFY_SUCCESS: Remote notify event. 

Explanation    Remote notify event was returned success.

Recommended Action    No action is required.

Error Message     LACP-5-LACP_SUSPEND_INDIVIDUAL: LACP port [chars] of port-channel 
[chars] not receiving any LACP BPDUs suspending (individual) port 

Explanation    LACP suspend individual ports

Recommended Action    No action is required.

Error Message     LACP-5-LACP_UPGRADE_READY_SUCCESS: Upgrade ready was returned 
success. 

Explanation    Upgrade ready event was returned success since all ports in port channels were found in steady state.

Recommended Action    No action is required.

Error Message     LACP-5-PORT_PRIORITY_CHANGED: [chars]: LACP port priority changed 
from [dec] to [dec] 

Explanation    LACP port priority has been changed

Recommended Action    No action is required.

Error Message     LACP-5-SYSTEM_PRIORITY_CHANGED: LACP system priority changed from 
[hex] to [hex] 

Explanation    LACP system priority has been changed

Recommended Action    No action is required.

LC-FCFWD Messages

This section contains the LC-FCFWD messages.

LC-FCFWD-3

Error Message    LC-FCFWD-3-ERROR: [chars] 

Explanation    Lc_fcfwd encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC-SPAN Messages

This section contains the LC-SPAN messages.

LC-SPAN-3

Error Message    LC-SPAN-3-ERROR: [chars] 

Explanation    Lc_span_mgr encountered an error

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC_CFG Messages

This section contains the L2_CFG messages.

LC_CFG-SLOT#-2

Error Message    LC_CFG-SLOT#-2-LC2_CPU_ERRORS: [chars], Total IC [dec], DC [dec], Tag 
[dec], MBit [dec], SBit [dec], I30 [dec] 

Explanation    LC CPU Cache errors.

Recommended Action    No action is required.

Error Message     LC_CFG-SLOT#-2-LC_CFG_ABORT: registration aborted with code [dec] 

Explanation    Process lc_cfg_mgr aborted registration

Recommended Action    No action is required.

Error Message     LC_CFG-SLOT#-2-LC_CFG_EXITED: exited with code [dec] 

Explanation    Process lc_cfg_mgr exited

Recommended Action    No action is required.

LC_PORT_CHANNEL Messages

This section contains the LC_PORT_CHANNEL messages.

LC_PORT_CHANNEL-SLOT#-0

Error Message    LC_PORT_CHANNEL-SLOT#-0-HW_FAILURE: fatal error in configureing 
[chars]: [chars] 

Explanation    Fatal hardware error in port-channel configuration

Recommended Action    Reset the module

Error Message     LC_PORT_CHANNEL-SLOT#-0-IDX_FULL: D_IDX table full (current [dec], 
new [dec], total [dec]) 

Explanation    Programming error in port-channel configuration

Recommended Action    Reset the module

LC_PORT_CHANNEL-SLOT#-3

Error Message     LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_ERROR: [chars] 

Explanation    General error

Recommended Action    No action is required.

Error Message     LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_IDXMAP_FAILURE: could not 
lookup port index for interface [chars] 

Explanation    Could not look up port index

Recommended Action    No action is required.

LC_PORT_MGR Messages

This section contains the LC_PORT_MGR messages.

LC_PORT_MGR-SLOT#-2

Error Message    LC_PORT_MGR-SLOT#-2-LC_MTS_ERROR: An MTS error has occurred in 
([chars]) with the following conditions: opc=[dec] ssap=[hex] dsap=[hex] 
syserr=[hex] 

Explanation    This is a software error in message communication between two applications.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LC_RDL Messages

This section contains the LC_RDL messages.

LC_RDL-3

Error Message    LC_RDL-3-SYSLOG_ALLOC_FAIL: : [chars] 

Explanation    RDL malloc failed : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_CONTEXT_ERR: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_ERR: : [chars] 

Explanation    RDL syslog errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_EXIT: : [chars] 

Explanation    RDL exiting on errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_INIT_FAIL: : [chars] [chars] 

Explanation    RDL Init Failed: [chars] [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_MTS_ERR: : [chars] 

Explanation    RDL MTS errors : [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-3-SYSLOG_MTS_REG_FAILED: : [dec] [dec] 

Explanation    RDL context error: [dec] [dec]

Recommended Action    No action is required.

LC_RDL-6

Error Message     LC_RDL-6-SYSLOG_DEBUG_1: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_DEBUG_2: : [chars] [hex] 

Explanation    RDL Debug logs: [chars] [dec]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_INFO: : [chars] 

Explanation    RDL Debug logs: [chars]

Recommended Action    No action is required.

Error Message     LC_RDL-6-SYSLOG_RESP_RCVD: : [chars] [dec] 

Explanation    RDL context error: [chars] [dec]

Recommended Action    No action is required.

LIBBASE_SVC Messages

This section contains the LIBBASE_SVC messages.

LIBBASE_SVC-2

Error Message    LIBBASE_SVC-2-IT_NEXUS_MAX_INTERFACE_LIMIT_REACHED: [chars] cannot be 
bound for site [chars], as the interfaces reached the maximum flow limit

Explanation    IT Load Balancing failed

Recommended Action    No action is required.

LIBBASE_SVC-5

Error Message     LIBBASE_SVC-5-FLOW_NOT_ALLOWED: Flow [chars] <-> [chars] disallowed 
in multiple clusters 

Explanation    Flow creation failed

Recommended Action    No action is required.

Error Message     LIBBASE_SVC-5-IT_NEXUS_FAILURE: [chars]. [chars] bind failure. 
Reason: [chars]: [hex] 

Explanation    IT Nexus bind failed

Recommended Action    No action is required.

Error Message     LIBBASE_SVC-5-IT_NEXUS_OPTIMUM_INTERFACE_LIMIT_REACHED: Interface 
[chars] exceeded the optimum flow limit 

Explanation    Iterface Flow Limit

Recommended Action    No action is required.

LIBGD Messages

This section contains the LIBGD messages.

LIBGD-2

Error Message    LIBGD-2-GD_ACCESS_FAILED: Guardian Failed to access reg for [chars] 

Explanation    Guardian Access failed

Recommended Action    No action is required.

Error Message     LIBGD-2-GD_CATASTROPHIC: Guardian catastrophic failure: [chars] 

Explanation    Guardian catastrophic error

Recommended Action    No action is required.

Error Message     LIBGD-2-GD_INTR: Guardian Interrupt occurred: [chars] 

Explanation    Interrupt occurred on the Guardian

Recommended Action    No action is required.

Error Message     LIBGD-2-SHUTDOWN: Guardian software process exiting: [chars] 

Explanation    Guardian shutting down

Recommended Action    No action is required.

LIBGD-3

Error Message     LIBGD-3-EN_DATA_FAILED: Guardian enable port failed for inst:[dec] 
port:[dec] 

Explanation    Guardian Enable port failed for the guardian

Recommended Action    No action is required.

LIBGD-5

Error Message     LIBGD-5-STARTING: Guardian process starting 

Explanation    Guardian process is being started

Recommended Action    No action is required.

LIBGD-6

Error Message     LIBGD-6-DIS_DATA: Guardian disable port done for inst:[dec] 
port:[dec] 

Explanation    Disabled port successfully for guardian

Recommended Action    No action is required.

Error Message     LIBGD-6-EN_PORT: Guardian enable port done for inst:[dec] port:[dec] 

Explanation    Enabled port for the Guardian

Recommended Action    No action is required.

Error Message     LIBGD-6-HW_INIT: GuardianHW initialization has been done for inst: 
[dec] port: [dec] 

Explanation    Guardian HW initializtion has been called[dec]

Recommended Action    No action is required.

LICMGR Messages

This section contains the LICMGR messages.

LICMGR-2

Error Message    LICMGR-2-LOG_LIC_EXIT: License manager exiting: [chars] 

Explanation    License manager exiting.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_GRACE_EXPIRED: Grace period expired for feature 
[chars]. 

Explanation    Unlicensed feature [chars] has exceeded it's grace time period. Applications using will be shut down immediately.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-2-LOG_LIC_INVALID_SERVER_LINE: License file [chars] contains 
invalid SERVER line. Contact TAC 

Explanation    Invalid SERVER line in license file.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_N1K_DEFAULT_LICENSE_EXPIRED: Default Evaluation 
license expired for feature [chars]. 

Explanation    Default Evaluation license expired for feature [chars].

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-2-LOG_LIC_NVRAM_DISABLED: Licensing NVRAM is not available. 
Grace period will be disabled: [chars]

Explanation    The Supervisor NVRAM block may have a hardware problem and may need to be replaced

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-2-LOG_LIC_USAGE: Feature [chars] is using [dec] licenses, only 
[dec] licenses are installed. Please make sure enough licenses are installed for 
the VEMs

Explanation    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Recommended Action    Licensing

Error Message     LICMGR-2-LOG_LIC_VENDOR_DOWN: License file contains invalid SERVER 
line. Vendor daemon down 

Explanation    Vendor daemon is down

Recommended Action    Licensing

LICMGR-3

Error Message     LICMGR-3-LOG_LICAPP_NO_LIC: Application [chars] running without 
[chars] license, shut down in [dec] days.

Explanation    Application [chars1] has not been licensed. The application will work for a grace period of [dec] days after which it will be shut down unless a license file for feature [chars2] is installed.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_CHECKOUT_FAIL_BAD_CLOCK: License checkout failed for 
feature [chars]([chars]) because system clock has been set back. Please set the 
clock to the correct value.

Explanation    License checkout failed for feature [chars]([chars]) because system clock has been set back. Please set the clock to the correct value.

Recommended Action    No action is required.

Error Message     LICMGR-3-LOG_LIC_FILE_MISSING: License file(s) missing for feature 
[chars]. 

Explanation    One or more license files for feature [chars] are missing and must be reinstalled.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_INVALID_HOSTID: Invalid license hostid VDH=[chars] 
for feature [chars]. 

Explanation    Feature [chars2] has a license with an invalid license hostid VDH=[chars1]. This can occur if a supervisor card with licensed features for one switch is installed on another switch.

Recommended Action    No action is required.

Error Message     LICMGR-3-LOG_LIC_LICENSE_EXPIRED: Evaluation license expired for 
feature [chars]. 

Explanation    The named feature has exceeded it's evaluation time period. Applications using the license will be shut down after a grace period.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_MESSAGE_ERROR: could not handle message: [chars] of 
type [dec] from addr [dec]:[dec]. 

Explanation    Could not handle a IPC message [chars] of type [dec1] sent by a component running on node [dec2] with sap [dec3].

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-3-LOG_LIC_NO_LIC: No license(s) present for feature [chars]. 
Application(s) shut down in [dec] days.

Explanation    Feature [chars] has not been licensed. The feature will work for a grace period of [dec] days after which application(s) using the feature will be shut down.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_SERVER_DOWN: License Server Down [dec] 

Explanation    A connection to the license server was lost.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     LICMGR-3-LOG_LIC_SPROM_LIC: Feature [chars] issued [dec] licenses 
without a valid license file. 

Explanation    Feature [chars] has been licensed [dec] times without a valid license file. This means one or more license files are missing for feature [chars] and must be reinstalled.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-3-LOG_LIC_TOO_MANY_LIC: Only [dec] licenses are supported for 
[chars] feature, where as [dec] licenses are installed.

Explanation    More licenses are installed than allowed.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

LICMGR-4

Error Message     LICMGR-4-LOG_LICAPP_EXPIRY_WARNING: Application [chars] evaluation 
license [chars] expiry in [dec] days. 

Explanation    Application [chars1] will exceed it's evaluation time period in [dec] days and will be shut down after a grace period unless a permanent license for feature [chars2] is installed.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_LICENSE_EXPIRY_WARNING: Evaluation license for 
feature [chars] will expire in [dec] days. 

Explanation    Feature [chars] will exceed it's evaluation time period in [dec] days and will be shut down.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_N1K_DEFAULT_EXPIRY_WARNING: Default Evaluation 
license for feature [chars] will expire in [dec] days. Please make sure to install 
enough permanent licenses so as to avoid any disruption in traffic.

Explanation    Feature [chars] will exceed it's default evaluation time period in [dec] days. Please make sure to install enough permanent licenses so as to avoid any disruption in traffic.

Recommended Action    Please install the license file to continue using the feature.

Error Message     LICMGR-4-LOG_LIC_N1K_EXPIRY_WARNING: Evaluation license for feature 
[chars] will expire in [dec] days. Please make sure to install enough permanent 
licenses so as to avoid any disruption in traffic.

Explanation    Feature [chars] will exceed it's evaluation time period in [dec] days. Please make sure to install enough permanent licenses so as to avoid any disruption in traffic.

Recommended Action    Please install the license file to continue using the feature.

LICMGR-6

Error Message     LICMGR-6-LOG_CHECKPOINT_CREATED: created during license expiry. 

Explanation    When a license expires, auto checkpoint is created to prevent configuration loss.

Recommended Action    Rollback can be done to the created checkpoint when a new license is installed.

Error Message     LICMGR-6-LOG_LIC_FEATURE_CLEARED: Cleared [dec] license(s) for 
feature [chars]. 

Explanation    Uninstalled [dec] license(s) for feature [chars].

Recommended Action    Use the 'show license usage' command to verify this license feature removal.

Error Message     LICMGR-6-LOG_LIC_FEATURE_INSTALLED: Installed [dec] license(s) for 
feature [chars]. 

Explanation    Installed [dec] license(s) for feature [chars].

Recommended Action    Use the 'show license usage' command to verify this license feature installation.

Error Message     LICMGR-6-LOG_LIC_LICENSE_CLEARED_ALL: Cleared all licenses. 

Explanation    Cleared all license files.

Recommended Action    No action is required.

Error Message     LICMGR-6-LOG_LIC_LICENSE_CLEARED: Cleared license file [chars]. 

Explanation    Uninstalled the named license file.

Recommended Action    Use the 'show license' command to verify this license removal.

Error Message     LICMGR-6-LOG_LIC_LICENSE_INSTALLED: Installed license file [chars]. 

Explanation    Installed the named license file.

Recommended Action    Use the 'show license' command to verify this license installation.

LLDP Messages

This section contains the LLDP messages.

LLDP-3

Error Message    LLDP-3-DETECT_MULTIPLE_PEERS: Multiple peers detected on [chars] 

Explanation    Multiple peers detected on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-INVALID_DCBXP_RECEIVED: Received an invalid DCBXP on [chars] 

Explanation    Received an invalid DCBXP on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-INVALID_LLDP_RECEIVED: Received an invalid LLDP on [chars] 

Explanation    Received an invalid LLDP on an interface

Recommended Action    No action is required.

Error Message     LLDP-3-LLDP_INTERNAL_ERROR: LLDP internal error: [chars] 

Explanation    Internal error is encountered

Recommended Action    No action is required.

LLDP-5

Error Message     LLDP-5-LLDP_DISABLED: LLDP Disabled 

Explanation    LLDP Service Disabled

Recommended Action    No action is required.

Error Message     LLDP-5-LLDP_ENABLED: LLDP Enabled 

Explanation    LLDP Service Enabled

Recommended Action    No action is required.

Error Message     LLDP-5-SERVER_ADDED: Server with Chassis ID [chars] Port ID [chars] 
management address [chars] discovered on local port [chars] in vlan [dec] 

Explanation    A new peer is discovered

Recommended Action    No action is required.

Error Message     LLDP-5-SERVER_REMOVED: Server with Chassis ID [chars] Port ID [chars] 
on local port [chars] has been removed 

Explanation    A peer is removed

Recommended Action    No action is required.

LLDP-6

Error Message     LLDP-6-DETECT_REMOTE_CHANGE: Remote change detected on [chars] 

Explanation    Remote change detected on an interface

Recommended Action    No action is required.

Error Message     LLDP-6-DETECT_REMOTE_DCBXP_CHANGE: Remote DCBXP change detected on 
[chars] 

Explanation    Remote DCBXP change detected on an interface

Recommended Action    No action is required.

MAC Messages

This section contains the MAC messages.

MAC-SLOT#-2

Error Message    MAC-SLOT#-2-MAC_INFO: [chars] 

Explanation    MAC Informational message

Recommended Action    No action is required.

MCAST Messages

This section contains the MCAST messages.

MCAST-2

Error Message    MCAST-2-SHUTDOWN: Process shutting down: [chars] 

Explanation    Mcast is shutting down

Recommended Action    The action depends on the situation. The multicast process can shut down gracefully because of a system restart (in which case no action needs to take place) or because of a failure. The message associated with the syslog should be self explanatory to understand the reason for the shutdown. If the process is able to restart properly, there is no immediate harm for the system stability and the suggested action is to report the syslog event together with an explanation of the operations most recently performed on the system.

MCAST-4

Error Message     MCAST-4-ERROR: [chars] 

Explanation    Mcast encountered a generic error

Recommended Action    No action is required.

MCAST-5

Error Message     MCAST-5-BAD_MSG: Received bad message: [chars] 

Explanation    Mcast has received a malformed/unrecognized message

Recommended Action    No action is required.

Error Message     MCAST-5-START: Process has been started 

Explanation    Mcast has been started

Recommended Action    No action is required.

MCECTEST Messages

This section contains the MCECTEST messages.

MCECTEST-3

Error Message    MCECTEST-3-ASSERTION_FAILED: [chars] 

Explanation    MCECTEST has hit an assert condition at file [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-INIT_FAIL: [chars] 

Explanation    MCECTEST Initialization failed. due to [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-INTERNAL_ERR: [chars] 

Explanation    MCECTEST encountered an internal error due to [chars]

Recommended Action    No action is required.

Error Message     MCECTEST-3-MTS_ERR: [chars] 

Explanation    MCECTEST encountered an MTS error due to [chars]

Recommended Action    No action is required.

MCECTEST-5

Error Message     MCECTEST-5-MCECTEST_DISABLED: MCECTEST Disabled 

Explanation    MCECTEST Service Disabled

Recommended Action    No action is required.

Error Message     MCECTEST-5-MCECTEST_ENABLED: MCECTEST Enabled 

Explanation    MCECTEST Service enabled

Recommended Action    No action is required.

MCECTEST-6

Error Message     MCECTEST-6-INTERNAL_INFO: [chars] 

Explanation    MCECTEST got an internal info [chars]

Recommended Action    No action is required.

MCM Messages

This section contains the MCM messages.

MCM-5

Error Message    MCM-5-MCM_SDB_UPDATE_FAILED: sdb update failed with ret_val [dec] 

Explanation    SDB updated failed for MCM

Recommended Action    No action is required.

MFDM Messages

This section contains the MFDM messages.

MFDM-2

Error Message    MFDM-2-INTERNAL_ERROR: MFDM-[chars] Internal error : show system 
internal mfdm errors for more information

Explanation    MFDM PD hit a internal error. show system internal mfdm errors for futher analysis.

Recommended Action    No action is required.

MODULE Messages

This section contains the MODULE messages.

MODULE-2

Error Message    MODULE-2-LCM_PRE_UPGRADE_GENERAL_FAIL: Pre upgrade message fails seq 
[dec] 

Explanation    Pre upgrade message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_DONE_GENERAL_FAIL: Upgrade done message fails 
SAP [chars] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_OVER_FAIL: Upgrade over message returned [dec] 
[hex] for SAP [dec] 

Explanation    Upgrade done message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_READY_FAIL: Upgrade ready message returned [dec] 
[hex] for SAP [dec] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-LCM_UPGRADE_READY_GENERAL_FAIL: Upgrade ready message fails 
SAP [chars] 

Explanation    Upgrade ready message failed.

Recommended Action    No action is required.

Error Message     MODULE-2-MOD_DIAG_FAIL: Module [dec] (serial: [chars]) reported 
failure [chars] due to [chars] in device [dec] (device error [hex])

Explanation    The module in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_DNLD_FAIL: Image download failed for module [dec] 
(serial: [chars]) 

Explanation    Module [decimal digit] failed to download a new image from the supervisor.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_FAIL: Initialization of module [dec] (serial: [chars]) 
failed 

Explanation    Module [decimal digit] reported a failure during the initialization phase and will be powered down.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all module <module number>'.

Error Message     MODULE-2-MOD_MAJORSWFAIL: Module [dec] (serial: [chars]) reported a 
critical failure in service [chars] 

Explanation    A critical failure in service [string] happened at module [decimal digit] is going to reset the module [decimal digit].

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_MINORSWFAIL: Module [dec] (serial: [chars]) reported a 
failure in service [chars] 

Explanation    A non-critical failure in service [string] happened at module [decimal digit] is not going to reset the module [decimal digit].

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_NOT_ALIVE: Module [dec] not responding... resetting 
(serial: [chars]) 

Explanation    Module [decimal digit] is not replying to the hello message: module manager is then going to reset the module.

Recommended Action    No action is required.

Error Message     MODULE-2-MOD_REGFAILED: Registration failed for module [dec] 

Explanation    Module [decimal digit] sent the registration message notifying a failure.

Recommended Action    Collect module internal information by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_SOMEPORTS_FAILED: Module [dec] (serial: [chars]) 
reported failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in 
device [dec] (error [hex])

Explanation    Module [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-2-MOD_UNKNOWN: Module type [[dec]] in slot [dec] is not 
supported 

Explanation    The software card id of module [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the commands 'show module internal all module [decimal digit]'

Error Message     MODULE-2-XBAR_DIAG_FAIL: Xbar [dec] (serial: [chars]) reported 
failure [chars] due to [chars] in device [dec] (device error [hex])

Explanation    The xbar in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

Error Message     MODULE-2-XBAR_FAIL: Initialization of xbar [dec] (serial: [chars]) 
failed 

Explanation    Xbar [decimal digit] reported a failure during the initialization phase and will be powered down.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.

Error Message     MODULE-2-XBAR_SOMEPORTS_FAILED: Xbar [dec] (serial: [chars]) reported 
failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] 
(error [hex])

Explanation    Xbar [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

Error Message     MODULE-2-XBAR_UNKNOWN: Xbar type [[dec]] in slot [dec] is not 
supported 

Explanation    The software card id of xbar [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the commands 'show module internal all xbar [decimal digit]'

MODULE-3

Error Message     MODULE-3-MOD_SRG_NOT_COMPATIBLE: Module [dec] (serial: [chars]) 
firmware is not compatible with supervisor, downloading new image

Explanation    The software version of module [decimal digit] is not supported by the supervisor.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

MODULE-4

Error Message     MODULE-4-MOD_WARNING: Module [dec] (serial: [chars]) reported warning 
[chars] due to [chars] in device [dec] (device error [hex])

Explanation    Module [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.

Error Message     MODULE-4-XBAR_WARNING: Xbar [dec] (serial: [chars]) reported warnings 
on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (device 
error [hex])

Explanation    Xbar [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.

Recommended Action    Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.

MODULE-5

Error Message     MODULE-5-ACTIVE_SUP_OK: Supervisor [dec] is active (serial: [chars]) 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module [dec] ended 

Explanation    Upgrade of the module has ended.

Recommended Action    No action is required.

Error Message     MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module [dec] started 

Explanation    Upgrade of the module has been started by installer

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_OK: Module [dec] is online (serial: [chars]) 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_REINIT: Re-initializing module [dec] (serial: [chars]) 

Explanation    Module [decimal digit] reported a failure during the initialization phase and will be rebooted.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all module <module number>'.

Error Message     MODULE-5-MOD_RESTART: Module [dec] is restarting after image download 

Explanation    Module [decimal digit] completed image download and is restarting.

Recommended Action    No action is required.

Error Message     MODULE-5-MOD_STARTUP_CFG_MISMATCH: The startup configuration cannot 
be applied to a different module type for module [dec] (serial: [chars]). [chars] 
module is replacing [chars].

Explanation    The startup configuration for module [decimal digit] contains information about a different type of module instead of containing information about the current one.

Recommended Action    No action is required.

Error Message     MODULE-5-STANDBY_SUP_OK: Supervisor [dec] is standby 

Explanation    Module [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-XBAR_OK: Xbar [dec] is online (serial: [chars]) 

Explanation    Xbar [decimal digit] is ready to be configured and be able to switch traffic.

Recommended Action    No action is required.

Error Message     MODULE-5-XBAR_REINIT: Re-initializing xbar [dec] (serial: [chars]) 

Explanation    Xbar [decimal digit] reported a failure during the initialization phase and will be rebooted.

Recommended Action    Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.

MODULE-6

Error Message     MODULE-6-MOD_PURGE_CONFIG: Purging the configuration for module [dec] 

Explanation    Notification is being sent to remove the module configurations.

Recommended Action    No action is required.

Error Message     MODULE-6-MOD_REG_OK: Registration succeeded for module [dec] 

Explanation    Module [decimal digit] sent a successful registration message.

Recommended Action    No action is required.

MONITOR Messages

This section contains the MONITOR messages.

MONITOR-3

Error Message    MONITOR-3-ETH_SPAN_CFG_DEST_IF_MEMBER_SRC_PROFILE: ERROR: Interface 
[[chars]] configured in session [[dec]] and being inherited by port profile 
[[chars]] in another session

Explanation    An interface is configured as destination and source at the same time (one as being inherited by a port-profile and the other as being directly configured as a source/destination of a session. This may result of monitor traffic loss in the interface. Please remove the interface from the port profile or from the monitor session.

Recommended Action    No action is required.

MONITOR-5

Error Message     MONITOR-5-ETH_SPAN_SESSION_DOWN: Session [dec] is down. Reason 
[chars] 

Explanation    Session is down, no further traffic will be spanned.

Recommended Action    No action is required.

Error Message     MONITOR-5-ETH_SPAN_SESSION_ERROR: Session [dec] is having error. 
Reason [chars] 

Explanation    The session is experiencing a problem.

Recommended Action    Delete the session and try to reconfigure it

Error Message     MONITOR-5-ETH_SPAN_SESSION_UP: Session [dec] is up. 

Explanation    Session is up now. You can monitor Spanned traffic at the destination ports

Recommended Action    No action is required.

MONITOR-6

Error Message     MONITOR-6-ETH_SPAN_SESSION_CREATED: Session [dec] created 

Explanation    A new span session has been created.

Recommended Action    No action is required.

Error Message     MONITOR-6-ETH_SPAN_SESSION_DELETED: Session [dec] deleted 

Explanation    Session has been deleted.

Recommended Action    No action is required.

NFM Messages

This section contains the NFM messages.

NFM-2

Error Message    NFM-2-COMMIT_FAIL: Commit failed: client [hex], [chars] 

Explanation    The DDB commit failed

Recommended Action    No action is required.

Error Message     NFM-2-DDB_FAILURE: DDB failure: [chars] 

Explanation    A DDB generated failure

Recommended Action    No action is required.

Error Message     NFM-2-EXITING: Exit reason: [chars] 

Explanation    The NFM service process has exited due to [char]. The process has probably been restarted automatically.

Recommended Action    No action is required.

Error Message     NFM-2-INIT_FAIL: NFM Service Init failed: [chars] 

Explanation    NFM Service initialization failed. [chars] explains the reason for the failure.

Recommended Action    No action is required.

Error Message     NFM-2-MALLOC_ERROR: Function [chars]: Size [dec] bytes 

Explanation    The NFM service could not allocate memory.

Recommended Action    Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.

Error Message     NFM-2-PSS_ERROR: [chars]: PSS ret. val=[dec] 

Explanation    The NFM service encountered error while operating on a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-2-VERIFY_FAIL: Verify failed - Client [hex], Reason: [chars], 
Interface: [chars] 

Explanation    The DDB Verify failed

Recommended Action    No action is required.

NFM-3

Error Message     NFM-3-DDB_ERROR: DDB error: [chars] 

Explanation    The DDB generated error

Recommended Action    No action is required.

Error Message     NFM-3-FEATURE_MANAGER_ERROR: [chars]: An error occurred processing a 
Feature Manager msg - error [chars] 

Explanation    An error occurred while processing a message from FEATURE Manager

Recommended Action    No action is required.

Error Message     NFM-3-HANDLE_IN_USE: [chars]: name: [chars] 

Explanation    The NFM service encountered a handle that was in use while reading a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-3-INVALID_HANDLE: [chars]: handle =[hex] 

Explanation    The NFM service encountered an invalid handle in a persistent storage database.

Recommended Action    No action is required.

Error Message     NFM-3-MONITOR_NOT_FOUND: Monitor with handle [hex] from source [hex] 

Explanation    An Export Msg from a Linecard contained an invalid Monitor handle

Recommended Action    No action is required.

Error Message     NFM-3-MTS_ERROR: NFM encountered the following MTS error: [chars] 

Explanation    NFM Service encountered an MTS error. [chars] specifies the context where the error occurred.

Recommended Action    No action is required.

Error Message     NFM-3-NFM_DDB_ERROR: DDB error: [chars] 

Explanation    The DDB generated error

Recommended Action    No action is required.

Error Message     NFM-3-PSS_CORRUPTED: [chars] PSS found corrupted 

Explanation    The NFM service has detected corruption in one of its persistent information database. The database would be recreated.

Recommended Action    No action is required.

Error Message     NFM-3-VLAN_PARSE_ERROR: [chars]: An error occurred processing a VLAN 
Mgr Parse msg [hex] 

Explanation    An error occurred while processing a message from VLAN Manager

Recommended Action    No action is required.

NFM-4

Error Message     NFM-4-DDB_WARNING: DDB warning: [chars] 

Explanation    The DDB generated warning

Recommended Action    No action is required.

Error Message     NFM-4-LICENSE_EXPIRED: The License has expired. 

Explanation    The NFM service requires a License to run and exits when the License expires.

Recommended Action    No action is required.

Error Message     NFM-4-NFM_DDB_WARNING: DDB warning: [chars] 

Explanation    The DDB generated warning

Recommended Action    No action is required.

Error Message     NFM-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec] 

Explanation    There was a version mismatch between the NFM service and one of its persistent storage databases. The persistent information has been translated to the new format.

Recommended Action    No action is required.

NFM-5

Error Message     NFM-5-FEATURE_DISABLED: NetFlow Disabled. 

Explanation    NetFlow Feature Disabled.

Recommended Action    No action is required.

Error Message     NFM-5-FEATURE_ENABLED: NetFlow Enabled. 

Explanation    NetFlow Feature Enabled.

Recommended Action    No action is required.

NFM-6

Error Message     NFM-6-BECAME_ACTIVE: Became ACTIVE from standby mode 

Explanation    The NFM service on the standby supervisor became active and it is ready to serve client requests.

Recommended Action    No action is required.

Error Message     NFM-6-BECAME_STDBY: Became STANDBY from active mode 

Explanation    The NFM service became standby from active mode.

Recommended Action    No action is required.

Error Message     NFM-6-DDB_NOTIF: DDB notification: [chars] 

Explanation    The DDB generated notification

Recommended Action    No action is required.

Error Message     NFM-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system 
manager: Reason=[chars] 

Explanation    The NFM service was unable to send heartbeat to the system manger

Recommended Action    No action is required.

Error Message     NFM-6-NFM_DDB_NOTIF: DDB notification: [chars] 

Explanation    The DDB generated notification

Recommended Action    No action is required.

Error Message     NFM-6-SERVICE_UP: Initialized [chars] 

Explanation    The NFM service is up and ready The service was initialized in [char] mode.

Recommended Action    No action is required.

Error Message     NFM-6-SRV_EXIT: NFM Service shutting down gracefully 

Explanation    NFM Service is shutting down gracefully. This is an informational message.

Recommended Action