The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. See "About the CLI Command Modes" section on page 1-3 to determine the appropriate mode for each command. For more information, refer to the Cisco MDS 9000 Family CLI Configuration Guide.

keepalive

To configure the message keepalive interval for the IKE protocol, use the keepalive command in IKE configuration submode. To revert to the default, use the no form of the command.

keepalive seconds

no keepalive [seconds]

Syntax Description

seconds

Specifies the number of seconds for the keepalive interval. The range is 120 to 86400.


Defaults

3600 seconds or 1 hour.

Command Modes

IKE configuration submode.

Command History

Release
Modification

2.0(x)

This command was introduced.


Usage Guidelines

The keepalive interface only applies to IKE version 2 tunnels.

To use this command, the IKE protocol must be enabled using the crypto ike enable command.

Examples

The following example shows how to configure the keepalive interval.

switch# config terminal
switch(config)# crypto ike domain ipsec
switch(config-ike-ipsec)# keepalive 7200

Related Commands

Command
Description

crypto ike domain ipsec

Enters IKE configuration mode.

crypto ike enable

Enables the IKE protocol.

show crypto ike domain ipsec

Displays IKE information for the IPsec domain.


kernel core

Use the kernel core command to generate a core dump for each module. Use the no form of this command to negate the command or revert to its factory

kernel core {limit number | module slot {force | level {all | header | kernel | ram | used-ram} | target ipaddress}

no kernel core {limit number | module slot {force | level {all | header | kernel | ram | used-ram} | target ipaddress}

Syntax Description

limit number

Limits the number of modules for which the core is generated. The range is 1 to 6.

module slot

Configures the module requiring the core generation.

force

Forces a module to dump kernel core.

level

Specifies the core dump level for the selected module.

all

Dumps all the memory (requires 1G of space)

header

Dumps kernel header only.

kernel

Dumps all kernel memory pages.

ram

Dumps all the RAM pages.

used-ram

Dumps all the used RAM pages.

target ipaddress

Configures the external server IP address on the same physical LAN.


Defaults

Disabled.

Command Modes

Configuration mode.

Command History

Release
Modification

1.1(1)

This command was introduced.


Usage Guidelines

Core dumps performed on the supervisor module can lead to packet loss, even in a dual supervisor configuration.

Examples

The following example limits core generation to two modules.

switch(config)# kernel core limit 2
succeeded

The following example configures module 5 to generate cores.

switch(config)# kernel core module 5
succeeded

The following example configures module 5 to generate only header-level cores.

switch(config)# kernel core module 5 level header
succeeded

The following example configures the external server.

switch(config)# kernel core target 10.50.5.5
succeeded

Related Commands

Command
Description

show kernel

Displays configured kernel core settings.

show running-config

Displays all switch configurations saved to PSS.



key

To configure the preshared key for the IKE protocol, use the key command in IKE configuration submode. To revert to the default, use the no form of the command.

key key-id {address ip-address | hostname name}

no key key-id {address ip-address | hostname name}

Syntax Description

key-id

Specifies the ID for the preshared key. The maximum length is 128 characters.

address ip-address

Specifies the peer IP address. The format is A.B.C.D.

hostname name

Specifies the peer host name. The maximum length is 128 characters.


Defaults

None.

Command Modes

IKE configuration submode.

Command History

Release
Modification

2.0(x)

This command was introduced.

3.0(1)

Added the hostname keyword.


Usage Guidelines

To use this command, the IKE protocol must be enabled using the crypto ike enable command.


Note The key command supports only the IPv4 format for IP address.


Examples

The following example shows how to configure the key.

switch# config terminal
switch(config)# crypto ike domain ipsec
switch(config-ike-ipsec)# key ctct address 10.10.100.231

The following example shows how to delete the configured key.

switch(config-ike-ipsec)# no key ctct address 10.10.100.231

The following example shows how to set the preshared key for the specified peer.

switch(config-ike-ipsec)# key sample hostname node1

The following example shows how to delete the preshared key for the specified peer.

switch(config-ike-ipsec)# no key sample hostname node1

Related Commands

Command
Description

crypto ike domain ipsec

Enters IKE configuration mode.

crypto ike enable

Enables the IKE protocol.

show crypto ike domain ipsec

Displays IKE information for the IPsec domain.


key-ontape

To configure keys on the tape mode and store the encrypted security keys on the backup tapes, use the key-ontape command. To disable this feature, use the no form of the command.

key-ontape

no key-ontape

Syntax Description

This command has no arguments or keywords.

Defaults

Disabled.

Command Modes

Cisco SME cluster configuration submode.

Command History

Release
Modification

3.2(2)

This command was introduced.


Usage Guidelines

This command allows the encrypted security keys to be stored on the backup tapes.


Note This feature is supported only for unique keys.


Before using this command, automatic volume grouping should be disabled by using the auto-volgrp command.

Examples

The following example enables the key-ontape feature:

switch# config terminal
switch(config)# sme cluster clustername1
switch(config-sme-cl)# key-ontape

The following example disables the key-ontape feature:

switch# config terminal
switch(config)# sme cluster clustername1
switch(config-sme0-cl)# no key-ontape

Related Commands

Command
Description

no shared-key

Specifies unique key mode.

no auto-volgrp

Disables automatic volume grouping.

show sme cluster key

Displays information about cluster key database.