Table Of Contents
SNMP Traps
Major Alarm Traps
Port Error Traps
Reset Traps
System Events Traps
Layer 1 Alarm Traps
SNMP Traps
The Cisco VG30D Voice Gateway is configured to generate SNMP Traps for up to 8 destinations. SNMP traps have been divided into five groups as follows:
• Major Alarm
• Port Errors
• Reset Traps
• System Events
• Layer 1 Alarms
To access the MIBs which define the Cisco VG30D Voice Gateway Traps may be accessed through links provided on the SNMP Configuration page when using the Cisco VG30D Voice Gateway Management Interface. Using the Save As facility in the browser, these MIBs may be saved to allow the information to be compiled into the Network Management System (NMS).
Major Alarm Traps
Trap Code
Description
45
Port is not operational
46
Port has been commissioned
47
Port has been decommissioned
Port Error Traps
Trap Code
Description
1
Layer 1 is operational
2
Layer 1 is not operational
20
Layer 2 is misconfigured
21
Layer 2 is operational
22
Layer 2 is not operational
30
Layer 3 is operational
31
Layer 3 is not operational
32
Layer 3 disabled
35
Alarm propagation on
36
Alarm propagation off
40
Loopback mode detected
41
Loopback mode cleared
42
Port impedance is set to 75 ohm
43
Port impedance is set to 120 ohm
Reset Traps
Trap Code
Description
55
Unit has been reset
90
Unit reset after restoring configuration
System Events Traps
Trap Code
Description
50
Fatal or watchdog error
51
Major alarms have been acknowledged
62
Media card fatal
70
Factory/Post is set to POST
71
Factory/Post is set to FACTORY
72
Management IP address change from craft port
73
Management subnet mask change from craft port
74
Management IP address change from webserver
75
Management subnet mask change from webserver
76
New software has been installed
77
New software has been activated by the webserver
78
New software has been activated by the Craft port
79
Webserver login detected
80
Webserver logout detected
81
Webserver login fail
82
System fully operational
83
Default configurations have been applied
91
Failed to restore configuration
Layer 1 Alarm Traps
Trap Code
Description
3
Layer 1 enabled
4
Layer 1 disabled
5
Layer 1 no signal
6
Layer 1 receiving AIS
7
Layer 1 lost sync
8
Layer 1 transmitting AIS
9
Layer 1 receiving RAI
10
Layer 1 has excessive errors
11
Layer 1 receiving RAI and E bits
12
Layer 1 transmitting no signal