Cisco 828 Router and SOHO 78 Router Hardware Installation Guide
Specifications and Cables

Table Of Contents

Specifications and Cables

System Specifications

Port Connector Pinouts

Cabling Specifications

Ethernet Cable Specifications

Maximum Cable Distances


Specifications and Cables


This appendix provides system, port, and cabling specifications for the Cisco 828 router and the SOHO 78 router.

System Specifications

Table A-1 outlines the system specifications for the Cisco 828 router and the SOHO 78 router.

Table A-1 System Specifications 

Description
Design Specification
Physical Dimensions
 

Dimensions (H x W x D)

2.0 x 9.7 x 8.5 in. (5.1 x 24.6 x 21.6 cm)

Dimensions with cables connected (H x W X D)

2.0 x 9.7 x 10.3 in. (5.1 x 24.6 x 26.2 cm)

Weight (excludes desktop power supply)

Cisco 828 router: 1.47 lb (0.67 kg)

SOHO 78 router: 1.43 lb (0.65 kg)

Environmental Operating Ranges
 

Nonoperating temperature

-4 to 149°F (-20 to 65°C)

Nonoperating humidity

5 to 95%, relative humidity

Nonoperating altitude

0 to 15,000 ft (4570 m)

Operating temperature

32 to 104°F (0 to 40°C)

Operating humidity

10 to 85%, relative humidity

Operating altitude

0 to 10,000 ft (3000 m)

Router Power
 

AC input voltage

100 to 240V

Frequency

50 to 60 Hz

Power consumption

15W maximum


For information on regulatory compliance, see the Regulatory Compliance and Safety Information for Cisco 828 and SOHO 78 Routers document that shipped with your router.


Warning  Ultimate disposal of this product should be handled according to all national laws and regulations.


Port Connector Pinouts

This section provides pinouts for the following connectors:

Ethernet— See Table A-2, Table A-4, and Table A-5

Console (for connecting a terminal or PC)—See Table A-3

Table A-2 Cisco 828 Router and SOHO 78 Router Ethernet Connector Pinouts (RJ-45) 

Pin
Function
(TO HUB/TO PC Button -
IN Position)
Function
(TO HUB/TO PC Button -
OUT Position)

1

TX+

RX+

2

TX-

RX-

3

RX+

TX+

4

Unused

Unused

5

Unused

Unused

6

RX-

TX-

7

Unused

Unused

8

Unused

Unused


Table A-3 Console Connector Pinouts (RJ-45)

Pin
Function

1

RTS

2

DTR

3

TXD

4

GND

5

GND

6

RXD

7

DSR

8

CTS


The console port is configured as a data communications equipment (DCE) device. The default parameters for the console port are as follows:

9600 baud

8 data bits

No parity

One stop bit

Cabling Specifications

This section provides specifications for the following types of Ethernet cables, which you might need to provide:

Straight-through

Crossover

This section also provides information on Ethernet cable distance limitations.

Ethernet Cable Specifications

Table A-4 provides the specifications for straight-through and crossover Ethernet cables. See the Glossary for definitions for straight-through and crossover Ethernet cables.

Table A-4 Ethernet Cable Specifications

Type
Category
Shielding

10BaseT

Category 3 or 5

Shielded twisted-pair (STP)

10BaseT

-

Unshielded twisted-pair (UTP)


Maximum Cable Distances

Table A-5 shows the maximum distances of Ethernet and xDSL cables that you can use.

Table A-5 Maximum Cable Distances

Cable
Maximum Distance

Ethernet cable

328 ft (100 m)

xDSL cable

500 ft (152 m)