Table Of Contents
Specifications and Cables
System Specifications
Port Connector Pinouts
Cabling Specifications
Ethernet Cable Specifications
Maximum Cable Distances
Specifications and Cables
This appendix provides system, port, and cabling specifications for the Cisco 828 router and the SOHO 78 router.
System Specifications
Table A-1 outlines the system specifications for the Cisco 828 router and the SOHO 78 router.
Table A-1 System Specifications
Description
|
Design Specification
|
Physical Dimensions
|
|
Dimensions (H x W x D)
|
2.0 x 9.7 x 8.5 in. (5.1 x 24.6 x 21.6 cm)
|
Dimensions with cables connected (H x W X D)
|
2.0 x 9.7 x 10.3 in. (5.1 x 24.6 x 26.2 cm)
|
Weight (excludes desktop power supply)
|
Cisco 828 router: 1.47 lb (0.67 kg)
SOHO 78 router: 1.43 lb (0.65 kg)
|
Environmental Operating Ranges
|
|
Nonoperating temperature
|
-4 to 149°F (-20 to 65°C)
|
Nonoperating humidity
|
5 to 95%, relative humidity
|
Nonoperating altitude
|
0 to 15,000 ft (4570 m)
|
Operating temperature
|
32 to 104°F (0 to 40°C)
|
Operating humidity
|
10 to 85%, relative humidity
|
Operating altitude
|
0 to 10,000 ft (3000 m)
|
Router Power
|
|
AC input voltage
|
100 to 240V
|
Frequency
|
50 to 60 Hz
|
Power consumption
|
15W maximum
|
For information on regulatory compliance, see the Regulatory Compliance and Safety Information for Cisco 828 and SOHO 78 Routers document that shipped with your router.
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Port Connector Pinouts
This section provides pinouts for the following connectors:
•
Ethernet— See Table A-2, Table A-4, and Table A-5
•
Console (for connecting a terminal or PC)—See Table A-3
Table A-2 Cisco 828 Router and SOHO 78 Router Ethernet Connector Pinouts (RJ-45)
Pin
|
Function
(TO HUB/TO PC Button - IN Position)
|
Function
(TO HUB/TO PC Button - OUT Position)
|
1
|
TX+
|
RX+
|
2
|
TX-
|
RX-
|
3
|
RX+
|
TX+
|
4
|
Unused
|
Unused
|
5
|
Unused
|
Unused
|
6
|
RX-
|
TX-
|
7
|
Unused
|
Unused
|
8
|
Unused
|
Unused
|
Table A-3 Console Connector Pinouts (RJ-45)
Pin
|
Function
|
1
|
RTS
|
2
|
DTR
|
3
|
TXD
|
4
|
GND
|
5
|
GND
|
6
|
RXD
|
7
|
DSR
|
8
|
CTS
|
The console port is configured as a data communications equipment (DCE) device. The default parameters for the console port are as follows:
•
9600 baud
•
8 data bits
•
No parity
•
One stop bit
Cabling Specifications
This section provides specifications for the following types of Ethernet cables, which you might need to provide:
•
Straight-through
•
Crossover
This section also provides information on Ethernet cable distance limitations.
Ethernet Cable Specifications
Table A-4 provides the specifications for straight-through and crossover Ethernet cables. See the Glossary for definitions for straight-through and crossover Ethernet cables.
Table A-4 Ethernet Cable Specifications
Type
|
Category
|
Shielding
|
10BaseT
|
Category 3 or 5
|
Shielded twisted-pair (STP)
|
10BaseT
|
-
|
Unshielded twisted-pair (UTP)
|
Maximum Cable Distances
Table A-5 shows the maximum distances of Ethernet and xDSL cables that you can use.
Table A-5 Maximum Cable Distances
Cable
|
Maximum Distance
|
Ethernet cable
|
328 ft (100 m)
|
xDSL cable
|
500 ft (152 m)
|