Table Of Contents
Hardware Specifications
A.1 ONS 15454 Shelf Specifications
A.1.1 Bandwidth
A.1.2 Configurations
A.1.3 Cisco Transport Controller
A.1.4 External LAN Interface
A.1.5 TL1 Craft Interface
A.1.6 Modem Interface
A.1.7 Alarm Interface
A.1.8 EIA Interface (ANSI only)
A.1.9 BITS Interface (ANSI only)
A.1.10 System Timing
A.1.11 System Power
A.1.12 Fan Tray
A.1.13 System Environmental Specifications
A.1.14 Dimensions
A.2 ONS 15454 M2 Shelf Specifications
A.2.1 Bandwidth
A.2.2 Configurations
A.2.3 Cisco Transport Controller
A.2.4 External LAN Interface for EMS
A.2.5 TL1 Craft Interface
A.2.6 Modem Interface
A.2.7 Alarm Interface
A.2.8 Passive Unit Remote Inventory
A.2.9 BITS Interface
A.2.10 System Timing
A.2.11 System Power
A.2.12 Fan Tray
A.2.13 System Environmental Specifications
A.2.14 Dimensions
A.3 ONS 15454 M6 Shelf Specifications
A.3.1 Bandwidth
A.3.2 Configurations
A.3.3 Cisco Transport Controller
A.3.4 External LAN Interface for EMS
A.3.5 TL1 Craft Interface
A.3.6 Modem Interface
A.3.7 Alarm Interface
A.3.8 Passive Unit Remote Inventory
A.3.9 BITS Interface
A.3.10 System Timing
A.3.11 System Power
A.3.12 Fan Tray
A.3.13 System Environmental Specifications
A.3.14 Dimensions
Hardware Specifications
This appendix contains hardware and software specifications of the ONS 15454 (ANSI and ETSI), ONS 15454 M2, and ONS 15454 M6 shelf.
Note
Unless otherwise specified, "ONS 15454" refers to both ANSI and ETSI shelf assemblies.
Note
Unless otherwise specified, the ECU module refers to the ECU, ECU2, and ECU-60V units. For details about the various ECU modules, see the "External Connection Units" section.
The following sections are included:
•
ONS 15454 Shelf Specifications
•
ONS 15454 M2 Shelf Specifications
•
ONS 15454 M6 Shelf Specifications
A.1 ONS 15454 Shelf Specifications
This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.
A.1.1 Bandwidth
The ONS 15454 has the following bandwidth specifications:
•
Total bandwidth: 240 Gbps
•
Data plane bandwidth: 160 Gbps
•
SONET/SDH plane bandwidth: 80 Gbps
A.1.2 Configurations
The ONS 15454 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:
•
Hubbed rings
•
Multihubbed rings
•
Point-to-point
•
Linear
•
Linear with optical add/drop multiplexing (OADM)
•
Hybrid terminal node
•
Hybrid OADM node
•
Hybrid line amplifier node
A.1.3 Cisco Transport Controller
CTC, the ONS 15454 craft interface software, has the following specifications:
•
10BaseT Ethernet
•
TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE card access: RJ-45 connector
•
Backplane access: LAN pin field (ANSI only)
•
Front Mount Electrical Connection (FMEC) access: LAN connector on MIC-C/T/P faceplate (ETSI only)
A.1.4 External LAN Interface
The ONS 15454 external LAN interface has the following specifications:
•
10BaseT Ethernet
•
Backplane access: LAN pin field (ANSI only)
•
FMEC access: LAN connector on MIC-C/T/P faceplate (ETSI only)
A.1.5 TL1 Craft Interface
The ONS 15454 TL1 craft interface has the following specifications:
•
Speed: 9600 bps
•
TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector
•
Backplane access: CRAFT pin field (ANSI only)
A.1.6 Modem Interface
The ONS 15454 modem interface has the following specifications:
•
Hardware flow control
•
TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector
A.1.7 Alarm Interface
The ONS 15454 alarm interface has the following specifications:
•
ETSI
–
Visual: Critical, Major, Minor, Remote
–
Audible: Critical, Major, Minor, Remote
–
FMEC access: 62-Pin DB connector on MIC-A/P faceplate
–
Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA
–
Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA
•
ANSI
–
Visual: Critical, Major, Minor, Remote
–
Audible: Critical, Major, Minor, Remote
–
Backplane access: Alarm pin fields
–
Alarm contacts: 0.045 mm, -48 V, 50 mA
A.1.8 EIA Interface (ANSI only)
The ONS 15454 electrical interface assembly (EIA) interface has the following specifications:
•
SMB: AMP #415504-3 75-ohm, 4-leg connectors
•
BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King or ITT are also compatible)
•
AMP Champ: AMP#552246-1 with #552562-2 bail locks
A.1.9 BITS Interface (ANSI only)
The ONS 15454 building integrated timing supply (BITS) interface has the following specifications:
•
2 DS-1 BITS inputs
•
2 derived DS-1 outputs
•
Backplane access: BITS pin field
A.1.10 System Timing
The ONS 15454 ANSI has the following system timing specifications:
•
Stratum 3 per Telcordia GR-253-CORE
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
The ONS 15454 ETSI has the following system timing specifications:
•
Stratum 3E, per ITU-T G.813
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
A.1.11 System Power
The ONS 15454 ANSI has the following power specifications:
•
Nominal Input Voltage: -48 VDC
•
Power consumption: Configuration dependent; 55 W (fan tray only)
•
Power requirements:
–
Nominal: -48 VDC
–
Input Voltage Range: -40.5 to -57.0 VDC
•
Power terminals: #6 Lug
•
ANSI shelf fusing: 100-A fuse panel (minimum 30 A fuse per shelf)
HD shelf fusing: 100-A fuse panel (minimum 30 A fuse per shelf)
The ONS 15454 ETSI has the following power specifications:
•
Nominal Input Voltage: -48 VDC
•
Power consumption: Configuration dependent; 53 W (fan tray only)
•
Power requirements:
–
Nominal: -48 VDC
–
Input Voltage Range: -40.5 to -57.0 VDC
•
Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates)
•
Fusing: 100 A fuse panel; minimum 30 A fuse per shelf
A.1.12 Fan Tray
Table A-1 lists power requirements for the fan-tray assembly.
Table A-1 Fan Tray Assembly Power Requirements
Fan Tray Assembly
|
Watts
|
Amps
|
BTU/Hr
|
FTA2
|
53
|
1.21
|
198
|
FTA3 -T
|
86.4
|
1.8
|
295
|
15454E-CC-FTA/15454-CC-FTA
|
115
|
2.4
|
393
|
A.1.13 System Environmental Specifications
The ONS 15454 ANSI has the following environmental specifications:
•
Operating temperature:
C-Temp: 32 to +131 degrees Farenheit (0 to +55 degrees Celsius)
I-Temp: -40 to +139 degrees Farenheit (-40 to +65 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
The ONS 15454 ETSI has the following environmental specifications:
•
Operating temperature: 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
A.1.14 Dimensions
The ONS 15454 ANSI shelf assembly has the following dimensions:
•
Height: 18.5 in. (40.7 cm)
•
Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached
•
Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)
•
Weight: 55 lb (24.947 kg) empty
The ONS 15454 ETSI shelf assembly has the following dimensions:
•
Height: 616.5 mm (24.27 in.)
•
Width: 535 mm (17 in.) without mounting ears attached
•
Depth: 280 mm (11.02 in.)
•
Weight: 26 kg empty (57.3 lb)
A.2 ONS 15454 M2 Shelf Specifications
This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.
A.2.1 Bandwidth
The ONS 15454 M2 has the following bandwidth specifications (depending on the applications):
•
Total bandwidth: 200 Gbps
•
Data plane bandwidth: 100 Gbps per slot
A.2.2 Configurations
The ONS 15454 M2 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:
•
Hubbed rings
•
Multihubbed rings
•
Point-to-point
•
Linear
•
Linear with optical add/drop multiplexing (OADM)
•
Line amplifier node
•
Transponder Shelf
•
Layer 2 aggregation shelf
A.2.3 Cisco Transport Controller
CTC, the ONS 15454 M2 craft interface software, has the following specifications:
•
10/100BaseT Ethernet
•
TNC/TNCE/TSC/TSCE card access: RJ-45 LAN connector on the controller front plate
A.2.4 External LAN Interface for EMS
The ONS 15454 M2 external LAN interface has the following specifications:
•
10/100BaseT Ethernet located on the power module
A.2.5 TL1 Craft Interface
The ONS 15454 M2 TL1 craft interface has the following specifications:
•
TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector
A.2.6 Modem Interface
The ONS 15454 M2 modem interface has the following specifications:
•
Hardware flow control
•
TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector
A.2.7 Alarm Interface
The ONS 15454 M2 does not support alarm interface.
A.2.8 Passive Unit Remote Inventory
The ONS 15454 M2 provides 1 standard USB port located on the power module to retrieve the passive units inventory data.
A.2.9 BITS Interface
The ONS 15454 M2 building integrated timing supply (BITS) interface has the following specifications:
•
1 DS-1 BITS inputs wire wrap for ANSI applications
•
1 derived DS-1 outputs wire wrap for ANSI applications
•
1 E1 BITS input DIN-1.0/2.3 for ETSI applications
•
1 E1 BITS output DIN-1.0/2.3 for ETSI applications
A.2.10 System Timing
The ONS 15454 M2 for ANSI has the following system timing specifications:
•
Stratum 3 per Telcordia GR-253-CORE
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
The ONS 15454 M2 for ETSI has the following system timing specifications:
•
Stratum 3, per ITU-T G.813
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
A.2.11 System Power
The ONS 15454 M2 has the following AC power specifications:
•
Input Voltage: 100V - 240V AC (+/- 10%)
•
Power consumption: Configuration dependent; 35 W (Fan Tray and LCD)
•
Power terminals standard 3 pole AC connector
•
For an AC power supply, the fuse rating must not exceed 10A, 15A, or 20A depending on the standard in various countries. For North America, the branch circuit protection must be rated 20A
•
Total maximum power consumption of 350W with ancillaries, controllers and linecards
The ONS 15454 M2 has the following DC power specifications:
•
Nominal Input Voltage: -48 VDC
•
Power consumption: Configuration dependent; 35 W (Fan Tray and LCD)
•
Power requirements:
–
Nominal: -48 VDC
–
Input Voltage Range: -40.5 to -57.6 VDC
•
Power terminals: DSUB 2 poles for ETSI applications and terminal block double pole for ANSI applications
•
External fuse must not exceed 15A
•
Total maximum power consumption of 450W with ancillaries, controllers and linecards
A.2.12 Fan Tray
Table A-5 lists power requirements for the fan-tray assembly.
Table A-2 Fan-Tray Assembly Power Requirements
Fan Tray Assembly
|
Watts
|
Amps
|
BTU/Hr
|
15454-M2-FTA
|
35
|
1
|
120
|
15454-M2-FTA2
|
40
|
1
|
135
|
A.2.13 System Environmental Specifications
The ONS 15454 M2 for ANSI environment has the following specifications:
•
Operating temperature: 23 to +131 degrees Farenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
The ONS 15454 M2 for ETSI environment has the following specifications:
•
Operating temperature: 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
A.2.14 Dimensions
The ONS 15454 M2 shelf assembly has the following dimensions:
•
Height: 3.5 inches (88.9 mm)
•
Width: 19 or 23 inches (482.6 or 584.2 mm) with mounting ears attached
•
Depth: 11.1 inches (281.94 mm)
•
Weight:
–
11.02 pounds (5 kg) with preinstalled air filter and no cards installed
–
15.40 pounds (6.82 kg) with the power module, fan-tray assembly and air filter installed but with no cards.
A.3 ONS 15454 M6 Shelf Specifications
This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and ONS 15454 M6 shelf dimensions.
The ONS 15454 M6 shelf is compliant with the ETS 300-119-4 standard.
A.3.1 Bandwidth
The ONS 15454 M6 has the following bandwidth specifications (depending on the applications):
•
Total bandwidth: 400 Gbps
•
Data plane bandwidth: 100 Gbps per slot
A.3.2 Configurations
The ONS 15454 M6 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:
•
Hubbed rings
•
Multihubbed rings
•
Point-to-point
•
Linear
•
Linear with optical add/drop multiplexing (OADM)
•
Hybrid terminal node
•
Hybrid OADM node
•
Hybrid line amplifier node
•
Transponder Shelf
•
Layer 2 aggregation shelf
A.3.3 Cisco Transport Controller
CTC, the ONS 15454 M6 craft interface software, has the following specifications:
•
10/100BaseT Ethernet
•
TNC/TNCE/TSC/TSCE card access: RJ-45 LAN connector on the controller front plate
•
Shelf access: RJ-45 LAN Connector located on the ECU or ECU2
A.3.4 External LAN Interface for EMS
The ONS 15454 M6 external LAN interface has the following specification:
•
10/100BaseT Ethernet located on the ECU or ECU2 and supports:
–
10/100 Mbps full duplex
–
Auto detection
A.3.5 TL1 Craft Interface
The ONS 15454 M6 TL1 craft interface has the following specifications:
•
Speed: 9600 bps
•
TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector
•
An alternative RJ-45 LAN connector on TNC/TNCE/TSC/TSCE or ECU or ECU2
A.3.6 Modem Interface
The ONS 15454 M6 modem interface has the following specifications:
•
Hardware flow control
•
TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector
A.3.7 Alarm Interface
The ONS 15454 M6 alarm interface has the following specifications:
•
2 SCSI Connectors located on the ECU or ECU2
•
Visual: Critical, Major, Minor, Remote
•
Audible: Critical, Major, Minor, Remote
•
Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA
•
Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA
A.3.8 Passive Unit Remote Inventory
The ONS 15454 M6 provide 12 standard USB ports located on the ECU or ECU2 to retrieve the inventory data from the passive units.
A.3.9 BITS Interface
The ONS 15454 M6 building integrated timing supply (BITS) interface has the following specifications:
•
2 T1 BITS inputs wire wrap for ANSI applications
•
2 derived T1 outputs wire wrap for ANSI applications
•
2 E1 BITS input DIN-1.0/2.3 for ETSI applications
•
2 E1 BITS output DIN-1.0/2.3 for ETSI applications
A.3.10 System Timing
The ONS 15454 M6 for ANSI has the following system timing specifications:
•
Stratum 3 per Telcordia GR-253-CORE
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
The ONS 15454 M6 for ETSI has the following system timing specifications:
•
Stratum 3, per ITU-T G.813
•
Free running accuracy: +/- 4.6 ppm
•
Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
•
Reference: External BITS, line, internal
A.3.11 System Power
The ONS 15454 M6 has the following AC power specifications:
•
Input voltage: 100 V to 240 V AC (+/-10%).
•
Power consumption: Configuration dependent; 130 W (Fan Tray, LCD, and ECU or ECU2).
•
Power terminals standard 3-pole AC connector.
•
Fuse rating for an AC power supply must not exceed 10 A, 15 A, or 20 A depending on the standard in various countries. For North America, the branch circuit protection must be rated 20 A.
•
Total maximum power consumption of 900 W with ancillaries, controllers, and line cards.
The ONS 15454 M6 has the following DC power specifications:
Table A-3 ONS 15454 M6 DC Power Specifications
DC Power Module
|
Rating
|
Nominal Voltage
|
Current
|
Input Voltage Range
|
Maximum Load
|
15454-M6-DC
|
30 Amp
|
-48 VDC
|
30 Amp
|
-40.5 to -57.6 VDC
|
1440 W
|
-60 VDC
|
24 Amp
|
-50 to -72 VDC
|
15454-M6-DC20
|
20 Amp
|
-48 VDC
|
20 Amp
|
-40.5 to -57.6 VDC
|
960 W
|
-60 VDC
|
16 Amp
|
-50 to -72 VDC
|
Note
When the ONS 15454 M6 shelf is powered at -60 VDC (nominal), only the TNC, OPT-AMP-C, OPT-AMP-17-C, OPT-EDFA-17, and OPT-EDFA-24 cards, and the 15454-M6-ECU-60 can be installed.
•
15454-M6-DC and 15454-M6-DC20 shelf power consumption (configuration dependent):
–
130 W with 15454-M6-FTA Fan Tray, LCD, and ECU module
–
140 W with 15454-M6-FTA2 Fan Tray, LCD, and ECU module
•
Power terminals—DSUB 3 poles for ETSI applications and terminal block, double pole for ANSI applications.
•
External fuse must not exceed 40 A.
A.3.11.1 Power Calculation
For the ONS 15454 M6 shelf that is powered by the 15454-M6-DC20 power module, the controller card calculates the total power consumption of the shelf, which is displayed in the Provisioning > Power Monitor tab in CTC. For the power calculation to function properly ensure that:
•
There is no MEA alarm on any card.
•
The LCD module is properly plugged-in.
The total power consumption value for the shelf is computed by aggregating the power consumption values of individual cards and ancillary units installed or pre-provisioned in the shelf. Table A-4 lists the power consumption values of the line cards that are considered for power calculation.
Table A-4 Line Card Power Consumption Values
Card
|
|
|
10GE_XP
|
79
|
40
|
10X10G-LC
|
70
|
25
|
100G-LC-C
|
150
|
90
|
32DMX
|
50
|
30
|
32DMX-O
|
50
|
30
|
32MUX
|
50
|
30
|
32WSS
|
65
|
20
|
4MD
|
50
|
30
|
40-DMX-C
|
50
|
30
|
40E-TXP-C
|
130
|
50
|
40E-MXP-C
|
143
|
50
|
40G-MXP
|
112
|
50
|
40G-MXP-C
|
143
|
50
|
40G-TXP
|
99
|
50
|
40G-TXP-C
|
130
|
50
|
40-MUX-C
|
50
|
30
|
40-SMR1-C
|
60
|
12
|
40-SMR2-C
|
70
|
12
|
40WSS-C
|
79
|
32
|
40WSS-CE
|
79
|
32
|
40-WXC-C
|
50
|
30
|
40-WXC-L
|
50
|
30
|
80-WXC-C
|
100
|
30
|
AD-1C
|
50
|
30
|
AD-2C
|
50
|
30
|
AD-4C
|
50
|
30
|
ADM-10G
|
160
|
20
|
AR_MXP
|
74
|
35
|
AR_XP
|
74
|
35
|
AR_XPE
|
74
|
35
|
C-TCDU
|
50
|
30
|
CFP-LC
|
140
|
40
|
CPT-PTM-4
|
130
|
60
|
CPT-PTF-4
|
200
|
80
|
F-TCDU
|
50
|
30
|
GE_XP
|
79
|
40
|
MS-ISC-100T
|
69
|
20
|
MXP_2.5G_10E
|
50
|
30
|
MXP_2.5G_10G
|
50
|
30
|
MXP_MR_10DME
|
74
|
40
|
MXP_MR_2.5G
|
60
|
35
|
MXPP_MR_2.5G
|
60
|
38
|
OPT-AMP-17-C
|
50
|
30
|
OPT-AMP-C
|
50
|
30
|
OPT-BST
|
50
|
30
|
OPT-BST-E
|
50
|
30
|
OPT-EDFA-17
|
50
|
30
|
OPT-EDFA-24
|
50
|
30
|
OPT-PRE
|
50
|
30
|
OPT-RAMP-C
|
55
|
11
|
OPT-RAMP-CE
|
58
|
11
|
OSC-CSM
|
27
|
15
|
OTU2-XP
|
70
|
37
|
PSM
|
50
|
30
|
RAMAN-COP
|
90
|
12
|
RAMAN-CTP
|
90
|
12
|
TNC and TNCE
|
62
|
0
|
TSC and TSCE
|
55
|
0
|
TXP_MR_10E
|
50
|
30
|
TXP_MR_10EX
|
53
|
30
|
TXP_MR_10G
|
50
|
30
|
TXP_MR_2.5G
|
50
|
30
|
TXPP_MR_10EX
|
53
|
30
|
TXPP_MR_2.5G
|
50
|
30
|
During power calculation, certain wattage is always reserved for ancillary units like the ECU, fan tray, and standby controller card, irrespective of whether they are present in the shelf or not. The reserved power for the ONS 15454 M6 shelf with a TNC or TNC-E controller card is 284 W, and for the TSC or TSC-E controller card it is 270 W.
Note
In the shelf powered by the15454-M6-DC20 power module, a new line card will not boot if it causes the power consumption of the shelf to exceed 960 W. The PWR-CON-LMT alarm is raised in the Alarms tab in CTC when the installation or pre-provisioning of a card causes the power consumption to exceed 960 W. You must uninstall and deprovision the card that caused the PWR-CON-LMT alarm.
A.3.12 Fan Tray
Table A-5 lists power requirements for the fan-tray assembly.
Table A-5 Fan-Tray Assembly Power Requirements
Fan Tray Assembly
|
Watts
|
Amps
|
BTU/Hr
|
15454-M6-FTA
|
120
|
3
|
410
|
15454-M6-FTA2
|
130
|
3.5
|
445
|
A.3.13 System Environmental Specifications
The ONS 15454 M6 for ANSI environment has the following specifications:
•
Operating temperature: 23 to +131 degrees Farenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
The ONS 15454 M6 for ETSI environment has the following specifications:
•
Operating temperature: 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
A.3.14 Dimensions
The ONS 15454 M6 shelf assembly has the following dimensions:
•
Height: 10.4 inches (264.16 mm)
•
Width: 19 or 23 inches (482.6 or 584.2 mm) with mounting ears attached
•
Depth: 11.1 inches (281.94 mm)
•
Weight:
–
23.55 pounds (10.680 kg) with preinstalled air filter and no cards installed
–
40.12 pounds (18.2 kg) with all the ancillary units (2 DC power modules, ECU or ECU2, fan-tray assembly and air filter) installed but with no cards.