Change Card Settings
This chapter explains how to change line and threshold settings on Cisco ONS 15454 SDH cards.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide as necessary.
Caution 
Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1.
D88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards—As needed, complete this procedure to change line and threshold settings for all electrical cards (E1-N-14, E1-42, E3-12, DS3i-N-12, and STM1E-12).
2.
D89 Modify Line Settings and PM Parameter Thresholds for Optical Cards—As needed, complete this procedure to change line and threshold settings for all optical (STM-N) cards.
3.
D118 Modify Alarm Interface Controller-International Settings—As needed, complete this procedure to change external alarms and controls and/or orderwire settings.
4.
D91 Upgrade E1-N-14 and DS3 i-N-12 Protect Cards from 1:1 Protection to 1:N Protection—As needed, complete this procedure to change the protection type on E-1 or DS-3 cards.
5.
D311 Modify Port Settings and PM Parameter Thresholds for SAN Cards—As needed, complete this procedure to change the FC_MR-4 card port and threshold settings.
6.
D330 Change Card or PPM Service State—As needed, complete this procedure to change the service state on a card or pluggable port module (PPM).
7.
D331 Manage Pluggable Port Modules—As needed, complete this procedure to provision a multirate PPM, assign the optical line rate, change the optical line rate, and delete PPMs.
NTP-D88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
Purpose
|
This procedure changes the line settings and performance monitoring (PM) parameter thresholds for electrical cards.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
D17 Install the Electrical Cards
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Caution 
Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to change the electrical card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the "NTP-D108 Back Up the Database" procedure to preserve the existing database.
Step 3
Perform any of the following tasks as needed:
•
D365 Change Line and Threshold Settings for E1-N-14 or E1-42 Cards
•
D340 Change Line and Threshold Settings for the E3-12 Cards
•
D341 Change Line and Threshold Settings for the DS3i-N-12 Cards
•
D342 Change Line and Threshold Settings for the STM1E-12 Card
Note
To change settings on the Alarm Profiles tab, see Chapter 9 "Manage Alarms."
Step 4
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-D89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
Purpose
|
This procedure changes the line settings and the PM parameter thresholds for optical (STM-N) cards.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
D16 Install STM-N Cards and Connectors
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Caution 
Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to change the STM-N card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Step 3
Perform any of the following tasks as needed:
•
D108 Change Line Settings for STM-N Cards
•
D343 Change SDH Threshold Settings for STM-N Cards
•
D109 Change Optics Thresholds Settings for STM-64 and MRC-12 Cards
•
D216 Change the STM-N Card ALS Maintenance Settings
Note
To change settings on the Provisioning > VC4 tab, go to the "DLP-D122 Enable Intermediate Path Performance Monitoring" task. To change settings on the Alarm Profiles tab, see Chapter 9 "Manage Alarms."
Step 4
Complete the "NTP-D108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-D118 Modify Alarm Interface Controller-International Settings
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to change the AIC-I card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Step 3
Perform any of the following tasks as needed:
•
D208 Change External Alarms Using the AIC-I Card
•
D209 Change External Controls Using the AIC-I Card
•
D210 Change AIC-I Card Orderwire Settings
Step 4
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-D91 Upgrade E1-N-14 and DS3 i-N-12 Protect Cards from 1:1 Protection to 1:N Protection
Purpose
|
This task converts E1-N-14 and DS3i-N-12 protect cards from 1:1 to 1:N protection.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
D71 Create a 1:1 Protection Group
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to convert the E1-N-14 and DS3i-N-12 cards from 1:1 to 1:N protection. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Step 3
Perform any of the following tasks as needed:
•
D176 Convert E1-N-14 Cards From 1:1 to 1:N Protection
•
D177 Convert DS3i-N-12 Cards From 1:1 to 1:N Protection
Step 4
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-D311 Modify Port Settings and PM Parameter Thresholds for SAN Cards
Purpose
|
This procedure changes the line settings and PM parameter thresholds for FC_MR-4 cards.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
D286 Install the FC_MR-4 Cards
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to change the STM-N card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Step 3
Perform any of the following tasks as needed:
•
D354 Change General Port Settings for the FC_MR-4 Card
•
D355 Change Distance Extension Port Settings for the FC_MR-4 Card
•
D356 Change Enhanced FC/FICON Port Settings for the FC_MR-4 Card
•
D465 Create FC_MR-4 RMON Alarm Thresholds
•
D466 Delete FC_MR-4 RMON Alarm Thresholds
Step 4
As needed, complete the "NTP-D108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-D330 Change Card or PPM Service State
Purpose
|
This procedure changes a card or port's service state, which is an autonomously generated state that gives the overall condition of the port.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
Chapter 2 "Install Cards and Fiber-Optic Cable"
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Note
On the STM64-XFP and MRC-12 cards, the PPM is equivalent to an optical port.
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to change the card service state.
Step 2
Click the Inventory tab.
Step 3
Click Admin State for the card or PPM you want to change, and choose an administrative state from the drop-down list: Unlocked or Locked,maintenance.
Step 4
Click Apply.
Step 5
If an error message opens indicating that the card or PPM state cannot be changed from its current state, click OK.
Depending on the Admin State you choose, the card or port/PPM transitions to a different service state. For more information about the service states and card state transitions, refer to the "Administrative and Service States" appendix of the Cisco ONS 15454 SDH Reference Manual.
Stop. You have completed this procedure.
NTP-D331 Manage Pluggable Port Modules
Purpose
|
This procedure provisions, changes, and deletes PPMs for the MRC-12 and STM64-XFP cards. (STM64-XFP cards are single-rate PPMs, and therefore can only be deleted.)
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
D107 Preprovision an SFP or XFP Device or
D335 Install GBIC or SFP/XFP Devices
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite or remote
|
Security Level
|
Provisioning or higher
|
Step 1
Complete the "DLP-D60 Log into CTC" task at the node where you want to provision, change, or delete PPMs. If you are already logged in, continue with Step 2.
Step 2
From the View menu, choose Go to Network View.
Step 3
Click the Alarms tab:
a.
Verify that the alarm filter is not turned on. See the D227 Disable Alarm Filtering as necessary.
b.
Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide.
c.
Complete the "DLP-D147 Export CTC Data" task to export alarm and condition information."DLP-D132 Provision a Multirate PPM on the MRC-12 Card" task
Step 4
As needed, complete the "DLP-D132 Provision a Multirate PPM on the MRC-12 Card" task. Single-rate PPMs do not require provisioning.
Step 5
As needed, complete the "DLP-D133 Provision the Optical Line Rate on the MRC-12 Card" task to assign an OC-3, OC-12, or OC-48 line rate.
Step 6
As needed, complete the "DLP-D134 Change the Optical Line Rate on the MRC-12 Card" task to change the line rate on a multirate PPM. You cannot change the optical line rate on single-rate PPMs.
Step 7
As needed, complete the "DLP-D135 Delete a PPM from the MRC-12 or STM64-XFP Card" task.
Stop. You have completed this procedure.