Cisco WAN Manager SNMP Service Agent Guide, 15.1
BERT Management

Table Of Contents

BERT Management

BERT Overview

BERT MIB Tables

Platform and Card Support

Start a BERT

Stop a BERT


BERT Management


This chapter contains examples for managing a a bit error rate test (BERT). The following topics are included:

BERT Overview

BERT MIB Tables

Platform and Card Support

Start a BERT

Stop a BERT

BERT Overview

A BERT is a diagnostic test performed on a network entity to ensure operational integrity. This test is performed when a network entity malfunctions. In addition, this test is considered a service-enabling test. This test must be performed before a network entity (for example line, port, and connection) is set up for service.


Note The Service Agent support is limited to line and port BERT. Connection BERT is not supported.


BERT MIB Tables

Use the following MIB tables for BERT management:

cwmIfBertTable

cwmIfBertResTable

Platform and Card Support

The CWM Service Agent supports a BERT for the following platforms:

MGX 8220

MGX 8850 (PXM1)—Requires SRM/SRME card.

MGX 8850 (PXM1E)—Requires SRM/SRME card.

MGX 8850 (PXM45)—Requires SRM/SRME card for AUSM, CESM, and FRSM cards.

Line and port BERT is supported on the following cards:

FRSM-8T1E1

CESM-8T1E1

VISM-8T1E1/VISM-PR-8T1E1

VXSM-T1E1, VXSM-155

FRSM-2CT3

AXSM-E-32T1E1

PXM1E-16T1E1

MPSM-8T1E1 (FR and CES)

MPSM-16T1E1

MPSM-16T1E1-PPP

MPSM-T3E3-155 (FR and ATM)

Only port BERT is supported on the AUSM-8T1E1 card.


Note SNMP GETNext is not supported on the BERT tables.


Start a BERT

You can start a BERT by entering a SET on the following object in the cwmIfBertTable:

cwmIfBertRowStatus.<INDEXing> = start

You can include other applicable read-write objects in the same SET request.

Once the BERT is started, parameters cannot be modified for the MGX 8220 platform.

While a BERT is running, you can retrieve results and statistics from the cwmIfBertResTable using a GET on the applicable parameters.


Note Restarting a BERT is not supported.


Stop a BERT

Since only a limited number of BERT sessions can coexist on a given device, it is always recommended that you stop the BERT once the desired results are retrieved.

To stop a BERT, send a SET request with the following object:

cwmIfBertRowStatus.<INDEXing> = stop

The results and statistics must be retrieved before you stop the BERT. Otherwise, they are not available once the BERT is stopped.