Table Of Contents
NE Explorer Information
B.1 Cisco IOS XR NE Explorer
B.1.1 Rack View
B.2 Cisco 7600 NE Explorer
B.2.1 Rack View
B.3 MGX Voice Gateway
B.4 ONS 15216 NE Explorer
B.4.1 Active ONS 15216 NEs
B.4.2 Passive ONS 15216 NEs
B.4.3 ONS 15216 Passive DCU NE Explorer
B.4.4 ONS 15216 DWDM NE Explorer
B.4.5 ONS 15216 FlexLayer NE Explorer
B.4.6 ONS 15216 Passive EDFA NE Explorer
B.4.7 ONS 15216 Active EDFA2 NE Explorer
B.4.8 ONS 15216 Active EDFA3 NE Explorer
B.4.9 ONS 15216 Active OADM NE Explorer
B.4.10 ONS 15216 Passive OADM NE Explorer
B.4.11 ONS 15216 OSC Passive NE Explorer
B.5 ONS 15302 and ONS 15305
B.6 ONS 15305 CTC NE Explorer
B.6.1 Node Properties Pane—ONS 15305 CTC
B.7 ONS 15310 CL NE Explorer
B.7.1 Node Properties Pane—ONS 15310 CL
B.8 ONS 15310 MA NE Explorer
B.8.1 Node Properties Pane—ONS 15310 MA
B.9 ONS 15327 NE Explorer
B.9.1 Node Properties Pane—ONS 15327
B.10 ONS 15454 MSTP NE Explorer
B.10.1 Node Properties Pane—ONS 15454 MSTP
B.10.2 Rack Properties Pane—ONS 15454 MSTP
B.10.3 Shelf Properties Pane—ONS 15454 MSTP
B.11 ONS 15454 SONET NE Explorer
B.11.1 Node Properties Pane—ONS 15454 SONET
B.12 ONS 15454 SDH NE Explorer
B.12.1 Node Properties Pane—ONS 15454 SDH
B.13 ONS 15501 NE Explorer
B.13.1 Identification Tab
B.13.2 Physical Tab
B.13.3 Power Source Tab
B.14 ONS 15530 and ONS 15540
B.15 ONS 15600 SONET NE Explorer
B.15.1 Node Properties Pane—ONS 15600 SONET
B.16 ONS 15600 SDH NE Explorer
B.16.1 Node Properties Pane—ONS 15600 SDH
B.17 ONS 15800 and ONS 15801 NE Explorer
B.17.1 Node Properties Pane—ONS 15800, ONS 15801
B.17.2 Rack Properties—ONS 15800, ONS 15801
B.17.3 Subrack Properties—ONS 15800, ONS 15801
B.18 ONS 15808 NE Explorer
B.18.1 Node Properties Pane—ONS 15808
B.18.2 Rack Properties—ONS 15808
B.18.3 Subrack Properties—ONS 15808
B.19 Unmanaged NE/Other Vendor Node Properties Pane
B.19.1 Identification Tab
NE Explorer Information
This appendix provides information on the various NE Explorer windows supported in CTM. This appendix contains the following sections:
•
Cisco IOS XR NE Explorer
•
Cisco 7600 NE Explorer
•
MGX Voice Gateway
•
ONS 15216 NE Explorer
•
ONS 15302 and ONS 15305
•
ONS 15305 CTC NE Explorer
•
ONS 15310 CL NE Explorer
•
ONS 15310 MA NE Explorer
•
ONS 15327 NE Explorer
•
ONS 15454 MSTP NE Explorer
•
ONS 15454 SONET NE Explorer
•
ONS 15454 SDH NE Explorer
•
ONS 15501 NE Explorer
•
ONS 15530 and ONS 15540
•
ONS 15600 SONET NE Explorer
•
ONS 15600 SDH NE Explorer
•
ONS 15800 and ONS 15801 NE Explorer
•
ONS 15808 NE Explorer
•
Unmanaged NE/Other Vendor Node Properties Pane
Note
In the CTM GUI, read-only fields have a gray background.
B.1 Cisco IOS XR NE Explorer
When you choose Configuration > NE Explorer for the Cisco CRS-1 or Cisco XR 12000, the window displayed by CTM consists of a tree on the left side and a rack graphic on the right. The tree provides a hierarchical view and alarm status of the device's racks, slots, ports, line cards, and power supplies. The tree view shows the card's operational status as a string after the card name, such as [Active: Running ENA]. The tree view displays the power supply slots as /rack.0/slot.PS0 and /rack.0/slot.PS1. The Rack View window provides information about the line card/fabric chassis that is selected in the NE Explorer tree. The NE Explorer is ported from the CRS-1 or Cisco XR 12000 craft web interface (CWI).
The Configuration and Administration menus in the NE Explorer window allow you to configure the CRS-1 or Cisco XR 12000 device. See 5.6 Configuring and Administering the CRS-1 and XR 12000, page 5-41 for detailed information about the Configuration and Administration menu options.
Figure B-1 NE Explorer—CRS-1
Figure B-2 NE Explorer—Cisco XR 12000
B.1.1 Rack View
The Rack View window displays a graphic of the CRS-1 or Cisco XR 12000 line-card chassis that is selected in the NE Explorer tree. Moving the mouse over the graphic displays the current number of critical, major, minor, and warning alarms for the rack, slot, or card. The right-click menu opens the Alarm Browser or the Alarm Log for the selected entity.
The background color of alarms in the Rack View window corresponds to alarm severity. The background alarm color is not configurable. The operational status of the rack is shown at the top of the graphic.
You can hide or show the front or rear chassis (for the CRS-1 only; this option is not available for the XR 12000). Right-click the chassis and choose Hide Front Chassis or Hide Rear Chassis. The menu option changes to Show Front Chassis or Show Rear Chassis.

Tip
The Magnify and Panned Zoom icons displayed in the Rack View are dimmed for chassis that contain a limited number of cards (where an adequately detailed view is already available without the need to zoom). For chassis that contain a higher number of cards—for example, the CRS-1, Cisco XR 12416, and Cisco XR 12016 models of the Cisco XR 12000—icons become active. To see an enlarged view of the entire chassis, click the Magnify icon, then click an area of the Rack View where you require a magnified view. A new window appears showing a magnified view centered on the location where you clicked. You can also click the Panned Zoom icon to see a magnified view of a limited area of the Rack View. A small expanded window view of the area of interest is displayed overlaying the Rack View. Move the cursor over an area of interest to see a magnified view.
Note
See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window.
B.2 Cisco 7600 NE Explorer
When you choose Configuration > NE Explorer for the Cisco 7600, the window displayed by CTM consists of a tree on the left side and a rack view graphic on the right. The tree provides a hierarchical view and alarm status of the device's racks, slots, ports, and line cards. Empty slots do not appear on the tree. The Rack View window displays the router processors, line cards, and chassis that the Cisco 7600 controls. Empty slots and unmanaged cards are visible in the Rack View window.
The Configuration and Administration menus in the NE Explorer window allow you to configure the Cisco 7600 device. When these menu options are selected, corresponding application windows appear. See 5.15 Configuring and Administering the Cisco 7600, page 5-330 for detailed information about the Configuration menu options. A user with read-only access can perform read-write operations in the Cisco 7600 NE Explorer.
Note
The number that appears in the Rack View and application window names indicates the number of windows launched on the right side of the NE Explorer.
Figure B-3 Cisco 7600 NE Explorer
B.2.1 Rack View
The Rack View window displays a graphic of the Cisco 7600 line-card chassis that is selected in the NE Explorer tree. Moving the mouse over the graphic displays the current number of critical, major, minor, and warning alarms for the rack, slot, or card. The right-click menu opens the Alarm Browser or the Alarm Log for the selected entity.
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.3 MGX Voice Gateway
The NE Explorer is not available for the MGX Voice Gateway. Equivalent functionality is provided through the Chassis View, which provides a graphical view of equipment status for the operational and alarm status of each card, port, or line. In the Domain Explorer tree, select an MGX node and choose Configuration > MGX Voice Gateway > Chassis View.
For information about the Chassis View, see 5.14 Configuring MGX Voice Gateway Devices, page 5-311.
Figure B-4 MGX Voice Gateway Chassis View
B.4 ONS 15216 NE Explorer
The NE Explorer for the ONS 15216 displays information about the selected ONS 15216 NE.
Figure B-5 NE Explorer—ONS 15216 DCU
ONS 15216 NEs are grouped as active NEs or passive NEs. Passive NEs do not have a management interface, so there is no communication between CTM and passive ONS 15216 NEs. For passive ONS 15216 NEs, the NE Explorer summarizes NE information that has been entered manually through the Domain Explorer and also allows you to specify the serial number. For active ONS 15216 NEs, the NE Explorer allows you to view the actual values of settings and parameters on the NE and modify configurable parameters.
Table B-1 ONS 15216 NEs
Active ONS 15216 NEs
|
Passive ONS 15216 NEs
|
ONS 15216 100-GHz OADM
|
ONS 15216 EDFA1
|
ONS 15216 EDFA2
|
ONS 15216 200-GHz OADM
|
ONS 15216 EDFA3
|
ONS 15216 100-GHz DWDM Filters
|
ONS 15216 200-GHz DWDM Filters
|
ONS 15216 OSC
|
ONS 15216 DCU
|
ONS 15216 FlexLayer
|
B.4.1 Active ONS 15216 NEs
The Network Element Properties pane for active ONS 15216 NEs displays information specific to the active ONS 15216 erbium-doped fiber amplifier (EDFA) and optical add/drop multiplexer (OADM) NEs. The properties pane contains the following tabs:
•
Status Tab
•
Identification Tab
•
Address Tab
•
NE Authentication Tab
The following table lists the different types of active ONS 15216 NEs.
Table B-2 List of Active ONS 15216 NE Types and Descriptions
Active ONS 15216 Types
|
Description
|
EDFA
|
Active EDFA with an IP address.
|
OADM
|
Active 100-GHz OADM with an IP address. The OADM can be a 1-, 2-, or 4-channel OADM.
|
B.4.1.1 Status Tab
The Status tab displays status information for the active NE.
Table B-3 Field Descriptions for the Status Tab
Field
|
Description
|
NE ID
|
Displays the user-defined name of the selected NE.
|
Description
|
Displays information that a user has entered (if any) to describe the NE.
|
NE Model
|
Identifies the model of the selected ONS 15216 NE.
|
Alarm Status
|
Displays the total number of critical, major, minor, and warning alarms currently existing on the selected NE.
|
Communication State
|
Displays the current connectivity state between CTM and the selected NE. Values are Available or Unavailable.
|
Operational State
|
Displays the current operational state of the selected NE and allows you to change the state. Values are In Service, Out of Service, and Under Maintenance.
|
B.4.1.2 Identification Tab
The Identification tab displays NE identification information.
Table B-4 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the user-defined name of the selected NE.
|
Description
|
Displays information that user has entered (if any) to describe the NE.
|
NE Model
|
Identifies the model of the selected ONS 15216 NE.
|
NE Type
|
Displays the ONS 15216 NE type.
|
Vendor Name
|
Displays the vendor name. The default vendor name is Cisco Systems.
|
Software Version
|
Displays the NE software version.
|
Version Name
|
Displays the name of the software version.
|
Location Name
|
Displays the geographic location of the selected NE.
|
B.4.1.3 Address Tab
The Address tab provides address information for the NE. If you change an address, the NE is reset automatically to make the new address selection valid.
Table B-5 Field Descriptions for the Address Tab
Field
|
Description
|
NE ID
|
Displays the user-defined name of the selected NE.
|
Description
|
Displays information that a user has entered (if any) to describe the NE.
|
NE Model
|
Identifies the model of the selected ONS 15216 NE.
|
Active IP Address
|
Displays the IP address of the selected NE.
|
SNMP Community String
|
Displays the configured community string name used in Simple Network Management Protocol (SNMP) messages. The community name is used to determine whether a user has access to the device.
|
GNE ID
|
Displays the ID for the gateway NE (GNE) on the selected NE ring.
|
Subnetwork ID
|
Displays the name of the subnetwork associated with the selected NE.
|
Network Partition ID
|
Displays the name of the network partition associated with the selected NE.
|
B.4.1.4 NE Authentication Tab
The NE Authentication tab allows you to specify user names and passwords for CTM server and CTM GateWay/TL1 connections to ONS 15216 NEs. Fields shown depend on the type of NE selected.
Table B-6 Field Descriptions for the NE Authentication Tab
Field
|
Description
|
CTM Server - NE Connection
|
Username
|
Specify the username that the CTM server uses to connect to ONS 15216 NEs.
|
Password
|
Specify the password to use for CTM server-to-NE connections.
|
Confirm Password
|
Retype the password to confirm it.
|
GateWay/TL1 - NE Connection
|
Username
|
Specify the username that CTM GateWay/TL1 uses to connect to ONS 15216 NEs.
|
Password
|
Specify the password to use for GateWay/TL1-to-NE connections.
|
Confirm Password
|
Retype the password to confirm it.
|
Note
Regardless of the actual size of the password, the Password and Confirm Password fields display only a fixed-length string. The fixed-length string is 12 asterisks (*).
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.2 Passive ONS 15216 NEs
The Network Element Properties pane for passive ONS 15216 NEs displays information specific to the passive EDFA, the passive OADM, the DCU, the OSC, and the DWDM ONS 15216 NEs. The passive ONS 15216 properties pane contains an Identification tab.
The following table lists the different types of passive ONS 15216 NEs.
Table B-7 List of Passive ONS 15216 NE Types and Descriptions
Passive ONS 15216 Types
|
Description
|
EDFA
|
Passive EDFA with no IP address or connectivity.
|
OADM
|
Passive 200-GHz OADM with no IP address or connectivity. The OADM can be either a 1- or 2-channel OADM.
|
DCU
|
Passive DCU with no IP address or connectivity.
|
OSC
|
Passive OSC with no IP address or connectivity.
|
DWDM
|
Passive DWDM filter with no IP address or connectivity. The DWDM filter can be a red, 200-GHz, DWDM filter; a blue, 200-GHz, DWDM filter; a red, 100-GHz, DWDM filter; or a blue, 100-GHz, DWDM filter.
|
B.4.2.1 Identification Tab
The Identification tab displays the NE identification information.
Table B-8 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the user-defined name of the selected NE.
|
Description
|
Displays information that a user has entered (if any) to describe the NE.
|
NE Model
|
Identifies the model of the selected NE (ONS 15216).
|
NE Type
|
Displays the ONS 15216 NE type.
|
Vendor Name
|
Displays the vendor name. The default vendor name is Cisco Systems.
|
Version Name
|
Displays the name of the software version.
|
Location Name
|
Displays the geographic location of the selected NE.
|
Operational State
|
Displays the current operational state of the system: In Service, Under Maintenance, or Out of Service.
|
Subnetwork ID
|
Displays the name of the subnetwork associated with the selected NE.
|
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.3 ONS 15216 Passive DCU NE Explorer
The ONS 15216 Passive DCU NE Explorer displays information about the ONS 15216 Passive DCU NE. It contains Identification, Slot 1, and Slot 2 tabs. (See Figure B-5.)
Each slot can accommodate any one of the following modules:
•
DCU-100 (100 ps/nm)
•
DCU-350 (350 ps/nm)
•
DCU-450 (450 ps/nm)
•
DCU-550 (550 ps/nm)
•
DCU-750 (750 ps/nm)
•
DCU-950 (950 ps/nm)
•
DCU-1150 (1150 ps/nm)
•
DCU-E-200 (200 ps/nm, ELEAF type)
•
DCU-E-350 (350 ps/nm, ELEAF type)
•
DCU-L-300 (300 ps/nm)
•
DCU-L-600 (600 ps/nm)
•
DCU-L-700 (700 ps/nm)
•
DCU-L-800 (800 ps/nm)
•
DCU-L-1000 (1000 ps/nm)
•
DCU-L-1100 (1100 ps/nm)
•
DCU-DS-L-100 (100 ps/nm)
•
DCU-DS-L-200 (200 ps/nm)
•
DCU-DS-L-300 (300 ps/nm)
B.4.3.1 Identification Tab
The Identification tab displays identification information for the ONS 15216 DCU NE.
Table B-9 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.3.2 Slot 1 and Slot 2 Tabs
The Slot 1 and Slot 2 tabs display information about the first and second slots. The fields in the tabs are identical, except that they pertain to different slots.
Table B-10 Field Descriptions for the Slot 1 and Slot 2 Tabs
Field
|
Description
|
Module Type
|
Displays the NE model type. Select one of the following module types:
• DCU-100 (100 ps/nm)
• DCU-350 (350 ps/nm)
• DCU-450 (450 ps/nm)
• DCU-550 (550 ps/nm)
• DCU-750 (750 ps/nm)
• DCU-950 (950 ps/nm)
• DCU-1150 (1150 ps/nm)
• DCU-E-200 (200 ps/nm, ELEAF type)
• DCU-E-350 (350 ps/nm, ELEAF type)
• DCU-L-300 (300 ps/nm)
• DCU-L-600 (600 ps/nm)
• DCU-L-700 (700 ps/nm)
• DCU-L-800 (800 ps/nm)
• DCU-L-1000 (1000 ps/nm)
• DCU-L-1100 (1100 ps/nm)
• DCU-DS-L-100 (100 ps/nm)
• DCU-DS-L-200 (200 ps/nm)
• DCU-DS-L-300 (300 ps/nm)
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
B.4.4 ONS 15216 DWDM NE Explorer
The NE Explorer for the ONS 15216 DWDM displays information about the passive ONS 15216 DWDM NE. It contains an Identification tab.
Figure B-6 NE Explorer—ONS 15216 DWDM
B.4.4.1 Identification Tab
The Identification tab displays identification information about the ONS 15216 DWDM NE.
Table B-11 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the Common Language Equipment Identification (CLEI) code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.5 ONS 15216 FlexLayer NE Explorer
The ONS 15216 FlexLayer NE Explorer displays information about the ONS 15216 FlexLayer NE. It contains Identification and Slot tabs.
Figure B-7 NE Explorer—ONS 15216 FlexLayer
B.4.5.1 Identification Tab
The Identification tab displays identification information about the ONS 15216 FlexLayer NE.
Table B-12 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.5.2 Slot 1 Through Slot 4 Tabs
The Slot tabs show module information pertaining to the selected ONS 15216 FlexLayer NE slot. The fields in the tabs are identical, except that they pertain to different slots.
Table B-13 Field Descriptions for the Slot 1 through Slot 4 Tabs
Field
|
Description
|
Module Type
|
Displays the type of module in the slot.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
B.4.6 ONS 15216 Passive EDFA NE Explorer
The ONS 15216 Passive EDFA NE Explorer displays information about the ONS 15216 Passive EDFA NE. It contains an Identification tab.
B.4.6.1 Identification Tab
The Identification tab displays identification information for the ONS 15216 Passive EDFA NE.
Table B-14 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.7 ONS 15216 Active EDFA2 NE Explorer
The ONS 15216 EDFA2 NE Explorer displays information about the ONS 15216 EDFA2 NE.
Figure B-8 NE Explorer—ONS 15216 EDFA2
The ONS 15216 EDFA2 NE Explorer contains the following tabs, some of which apply only to a specific NE version:
•
Identification Tab
•
Address Tab
•
Config/Status Tab
•
Diagnostics Tab
•
Thresholds Tab
•
Alarm Behavior Tab
•
SNMP Tab
B.4.7.1 Identification Tab
The Identification tab displays identification information about the ONS 15216 EDFA2 NEs.
Table B-15 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Wavelength(s)
|
Displays the number of wavelengths for the NE. This field is not applicable to the active EDFA NE type.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
Location
|
Latitude
|
Allows you to set the latitude in the database. Select North or South from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Longitude
|
Allows you to set the longitude in the database. Select East or West from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Date and Time
|
Time
|
Displays the NE date and time.
|
Time Zone
|
Displays the time zone where the NE is located.
|
Use Daylight Savings Time
|
If checked, Daylight Savings Time is observed.
|
B.4.7.2 Address Tab
The Address tab displays information about the NE network address.
Table B-16 Field Descriptions for the Address Tab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE.
|
Gateway Address
|
Displays the gateway address of the NE.
|
SNMP Community String
|
Displays the SNMP community string of the NE. You can edit this field.
|
GNE ID
|
Displays the GNE ID.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.7.3 Config/Status Tab
The Config/Status tab displays the configuration settings and status of the EDFA2.
Table B-17 Field Descriptions for the Config/Status Tab
Field
|
Description
|
Overall
|
Overall Gain
|
Displays the value of the gain set point in dB when the mode is GAINTEMP (gets cerent15216EdfaConstGainOverallGainMeasured). Must be an integer from 13.0 to 22.0.
|
Measured Gain
|
Displays the measured overall gain in dB. The range is from 0.0 to 23.0.
Note If there is no input power, this field reports a negative (invalid) value.
|
Pre-Attenuation
|
Displays the gain preattenuation value in dB (gets cerent15216EdfaVariableGainPreAttenuationMeasured). Must be an integer from 0.0 to 11.0.
|
Input Power
|
Displays the EDFA2 input power. Must be an integer from -9999.99 to 9999.99.
|
Output Power
|
Displays the EDFA2 output power. Must be an integer from -999.99 to 999.99.
|
DC Power Bus Mode
|
Displays the power bus mode setting (Simplex or Duplex) and allows you to change the mode.
|
Auto Laser Shutdown
|
Allows you to enable (On) or disable (Off) auto laser shutdown for the EDFA2.
Note The auto laser shutdown feature is available for the ONS 15216 EDFA2 R2.4 and later.
|
Pump
|
Control Mode Setting
|
Displays the control mode of the laser pumps. Constant gain is achieved by using an automatic control circuit that adjusts pump power when changes in input power are detected. The ONS 15216 EDFA2 operates in Constant Gain Temperature Compensated mode by default, but since there might be applications where other operating modes are required, the ONS 15216 EDFA2 can be set to operate in any one the following pump control modes:
• Constant Gain Temperature Compensated mode (ConstGainTempComp; Cisco default).
• Constant Output Power mode (ConstOutputPower).
Note Pump 1 cannot be set to ConstOutputPower mode.
• Constant Pump Current mode (ConstCurrent).
• Constant Pump Power mode (ConstPower).
• Idle—Laser pumps can be shut down using the Idle control mode.
Caution  Use the pump control modes Constant Output Power, Constant Pump Current, and Constant Pump Power with extreme caution. These modes are service affecting and can reduce the lifecycle of the lasers if used in extreme conditions. The factory default setting and the recommended mode of operation is Constant Gain Temperature Compensated mode. It is recommended that you contact the Cisco TAC before changing from this mode of operation.
|
Actual Control Mode
|
Displays the actual control mode of the laser pumps.
|
Constant Pump Current
|
Displays the laser pump constant pump current in milliamperes (mA). This is the current used when the control mode is changed to constCurrent. When changing Pump 1, Pump 2 is changed automatically when the Apply button is clicked.
|
Constant Pump Power
|
Displays the constant pump power in milliwatts (mW). The range is from 0 to 100 mW; the Cisco default is 0. You must set the constant power of pump 1 and pump 2 at the same time.
|
Constant Output Power
|
Displays the constant output power in mW. Only Pump2 is writeable. When ConstOutputPower is selected as the control mode, this field is enabled and editable for Pump2 and not for Pump1. The Const Power field is enabled with the Cisco default value (0). The range is from 0.0 to 65.0 mW.
|
B.4.7.4 Diagnostics Tab
The Diagnostics tab allows you to view NE laser pump attributes.
Table B-18 Field Descriptions for the Diagnostics Tab
Field
|
Description
|
Gain Module Temp
|
Displays the gain module temperature in degrees Celsius. Must be an integer from -99.99 to 99.99.
|
Gain Module Volt
|
Displays the gain module voltage in volts. Must be an integer from 0 to 999.
|
Input Power
|
Displays the laser input power in dBm. Must be an integer from -9999.99 to 9999.99.
|
Output Power
|
Displays the laser output power in dBm. Must be an integer from -999.99 to 999.99.
|
Gain
|
Displays the laser gain in dB. Must be an integer from -999.9 to 999.9.
|
Pump
|
Chip Temp
|
Displays the chip temperature in degrees Celsius. Must be an integer from -999.9 to 999.9.
|
Chip Temp Set Pt.
|
Displays the chip temperature set point in degrees Celsius. Must be an integer from 0.0 to 99.9.
|
TEC Current
|
Displays the TEC current in mA. Must be an integer from 0 to 99999.
|
Current
|
Displays the laser current in mA. Must be an integer from 0 to 999.
|
Power
|
Displays the pump power in mW. Must be an integer from 0.0 to 999.99.
|
B.4.7.5 Thresholds Tab
The Thresholds tab displays the threshold settings of the EDFA2.
Table B-19 Field Descriptions for the Thresholds Tab
Field
|
Description
|
Input Power
|
Threshold
|
Displays the input power threshold value in dBm. Must be an integer from -31 to -15.
|
Hysteresis
|
Displays the input power hysteresis value in dB. Must be an integer from 0 to 10.
|
Input Power
|
Displays the input power threshold value. Must be an integer from -9999.99 to 9999.99.
|
Output Power
|
Alm Deviation
|
Displays the output power alarm deviation value in dB. Must be an integer from 0 to 10.
|
Alm Hysteresis
|
Displays the output power alarm hysteresis value in dB. Must be an integer from 0 to 10.
|
Output Power Setpt
|
Displays the output power setpoint threshold value.
|
Gain
|
Min Gain
|
Displays the minimum gain setting. Must be an integer from -999.99 to 999.99.
|
Max Gain
|
Displays the maximum gain setting. Must be an integer from -999.99 to 999.99.
|
Measured Gain
|
Displays the value of the gain in dB when the mode is GAINTEMP (gets cerent15216EdfaConstGainOverallGainMeasured). Must be an integer from 0 to 23.
|
Gain Module Temperature
|
Min Temperature
|
Displays the minimum case temperature in degrees Celsius. Must be an integer from -10 to 10.
|
Max Temperature
|
Displays the maximum case temperature in degrees Celsius. Must be an integer from 20 to 70.
|
Min Hysteresis
|
Displays the minimum case temperature hysteresis in degrees Celsius. Must be an integer from 0 to 10.
|
Max Hysteresis
|
Displays the maximum case temperature hysteresis in degrees Celsius. Must be an integer from 0 to 10.
|
Power Bus
|
Power Bus Min
|
Displays the minimum allowable power bus DC voltage. Must be an integer from -70 to -35.
|
Power Bus Max
|
Displays the maximum allowable power bus DC voltage. Must be an integer from -70 to -35.
|
Laser 1 Current
|
Out-of-Range
|
Displays the Laser 1 pump temperature that is out of range.
|
Current
|
Displays the current of the Laser 1 pump in mA.
|
Laser 2 Current
|
Out-of-Range
|
Displays the Laser 2 pump temperature that is out of range.
|
Current
|
Displays the current of the Laser 2 pump in mA.
|
Laser 1 Temperature
|
Temp Min
|
Displays the minimum temperature of Laser 1.
|
Temp Max
|
Displays the maximum temperature of Laser 1.
|
Chip Temp
|
Displays the Laser 1 chip temperature in degrees Celsius. Must be an integer from -999.99 to 999.99.
|
Laser 2 Temperature
|
Temp Min
|
Displays the minimum temperature of Laser 2.
|
Temp Max
|
Displays the maximum temperature of Laser 2.
|
Chip Temp
|
Displays the Laser 2 chip temperature in degrees Celsius. Must be an integer from -999.99 to 999.99.
|
B.4.7.6 Alarm Behavior Tab
The Alarm Behavior tab allows you to enter, save, view, and update NE fault management attributes.
Table B-20 Field Descriptions for the Alarm Behavior Tab
Field
|
Description
|
Probable Cause
|
Displays the probable cause of the alarm.
|
Severity
|
Displays the alarm severity (Critical, Major, Minor, Informational, or Not Alarmed).
Note If two minor power bus alarms are generated, the second alarm is escalated to critical in the Alarm Browser window. If the alarm severity is changed to another value, the alarm remains critical due to the power bus escalation feature, which overrides the alarm severity provisioning for power bus alarms.
|
B.4.7.7 SNMP Tab
The SNMP tab displays the settings for the SNMP Community table, the Trap Destination table, and SNMP views. The SNMP tab contains the following subtabs: SNMP Community Table, Trap Destination Table, and SNMP Views.
Table B-21 Field Descriptions for the SNMP Tab
Field
|
Description
|
SNMP Community Table
|
Community Name
|
Displays the SNMP community name.
|
View Index
|
Displays the view index that specifies which MIBs that the community string can access.
|
Privileges
|
Displays the bitmap of access privilege that govern what management operations a particular community can perform. These privileges are expressed as a sum of values, where each value represents a particular operation. The decimal values and their respective SNMP operation are:
• 1—Get
• 2—GetNext
• 4—Response (enabled for all community strings)
• 8—Set
• 16—SNMPv1-Trap
• 32—GetBulk
• 64—Inform (enabled for all community strings)
• 128—SNMPv2-Trap (enabled for all community strings)
For example, 255 is the sum of all decimal values and specifies access to all SNMP operations. This sum is the default private community. 247 is the sum for all SNMP operations with the exception of the Set operation. This sum is the default public community.
Use the buttons in the Privileges column to set privilege values. In the Privilege Editor dialog box, check the check boxes that correspond to the privileges that you want to set. After making your selections, click OK. CTM computes the bit value automatically.
|
IP Address
|
Displays the source IP address.
|
Subnet Mask
|
Displays the subnet mask for the source IP address.
|
Status
|
Displays the community string status. Values are:
• Active
• Not in Service
• Not Ready
• Create and Go
• Create and Wait
• Destroy
|
Trap Destination Table
|
IP Address
|
Displays the trap destination IP address.
|
UDP Port
|
Displays the trap destination UDP port.
|
Community Name
|
Displays the trap destination community string.
|
Version
|
Displays the trap version number.
|
View Index
|
Displays the trap destination MIB view index.
|
Status
|
Displays the community string status. Values are:
• Active
• Not in Service
• Not ready
• Create and Go
• Create and Wait
• Destroy
|
SNMP Trap Enable check box
|
If checked, allows you to enable SNMP traps on the NE.
Note This is a global setting, meaning all users are affected by a change to this setting.
|
SNMP Views
|
View Index
|
Displays the view index number, which is a unique value for each MIB view.
|
Subtree
|
Displays an object identifier that designates a subtree element in the MIB hierarchy.
|
Mask
|
Displays a bit mask that identifies objects in the subtree.
|
Type
|
Displays a flag that specifies the status of the view. Valid entries are included and excluded.
|
Status
|
Indicates the status of the SNMP view entry. If the entry currently exists, the status is active.
|

Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.8 ONS 15216 Active EDFA3 NE Explorer
The ONS 15216 EDFA3 NE Explorer displays information about the ONS 15216 EDFA3 NE.
Figure B-9 NE Explorer—ONS 15216 EDFA3
The ONS 15216 EDFA3 NE Explorer contains the following tabs:
•
Identification Tab
•
Address Tab
•
Config/Status Tab
•
Diagnostics Tab
•
Thresholds Tab
•
Alarm Behavior Tab
•
SNMP Tab
B.4.8.1 Identification Tab
The Identification tab displays identification information for the ONS 15216 EDFA3 NE.
Table B-22 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Wavelength(s)
|
Displays the number of wavelengths for the NE. This field is not applicable to the active EDFA NE type.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
NE Date and Time
|
Displays the date and time configured on the NE.
|
Location
|
Latitude
|
Allows you to set the latitude of the NE. Select North or South from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Longitude
|
Allows you to set the longitude of the NE. Select East or West from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
B.4.8.2 Address Tab
The Address tab displays information about the NE network address.
Table B-23 Field Descriptions for the Address Tab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE.
|
Gateway Address
|
Displays the gateway address of the NE.
|
SNMP Community String
|
Displays the SNMP community string of the NE. You can edit this field.
|
MAC Address
|
Displays the ONS 15216 EDFA3 address as it is identified on the IEEE 802 MAC layer.
|
GNE ID
|
Displays the GNE ID.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
B.4.8.3 Config/Status Tab
The Config/Status tab displays the configuration settings and status of the EDFA3 and lasers.
Table B-24 Field Descriptions for the Config/Status Tab
Field
|
Description
|
Control Mode
|
Control Mode
|
Displays the amplifier control mode. Values are:
• Constant Output Power
• Constant Gain (Cisco default)
|
Gain
|
Gain
|
Displays the gain value. Values are integers from 0 to 40 dB.
|
Gain Setpoint
|
Displays the gain setpoint. The range is from 5.0 to 38.5 dB; the Cisco default is 21 dB.
|
Power
|
Laser 1 Output Power
|
Displays the amplifier output power related to laser 1. The range is from -60 to 25 dBm.
|
Power Setpoint
|
Displays the amplifier output power setpoint value. The range is from -7 to 17 dBm; the Cisco default is 10 dBm.
|
Amplifier Input Power
|
Displays the amplifier input power. The range is from -60 to 25 dBm.
|
Laser 2 Input Power
|
Displays the mid-stage access input power value related to laser 2. The range is from -60 to 25 dBm.
|
Amplifier Output Power
|
Displays the mid-stage access output power value. The range is from -60 to 25 dBm.
|
Power Offset
|
Displays the output power offset. The range is from -20 to 20 dBm; the Cisco default is 0.
|
Tilt
|
Tilt
|
Displays the tilt value. The range is from -15 to 15 dB.
|
Tilt Setpoint
|
Displays the tilt setpoint. The range is from -15 to 15 dB; the Cisco default is 0 dB.
|
Tilt Offset
|
Displays the tilt offset. The range is from -20 to 20 dB; the Cisco default is 0 dB.
|
Laser
|
Laser Status
|
Displays the automatic laser shutdown (ALS) status. Values are:
• On—Lasers are on
• APR—Lasers are in the automatic power reduction state
• Off—Lasers are off
|
OSRI
|
Displays the OSRI. Values are:
• On—Laser switch is locked on
• Off—(Cisco default) There is no lock on the lasers
|
DC Power Bus Mode
|
DC Power Bus Mode
|
Displays the power bus mode: Simplex or Duplex.
|
B.4.8.4 Diagnostics Tab
The Diagnostics tab displays diagnostics information for the EDFA3 and lasers.
Table B-25 Field Descriptions for the Diagnostics Tab
Field
|
Description
|
DCU Insertion Loss
|
Displays the insertion loss of the DCU inserted in mid-stage. The range is from 0 to 20 dB.
|
VOA Value
|
Displays the VOA value. The range is from -100 to 100 dB.
|
Laser Bias
|
Laser 1 Bias
|
Displays the laser 1 bias. The range is from 0 to 150 mA.
|
Laser 2 Bias
|
Displays the laser 2 bias. The range is from 0 to 150 mA.
|
Temperatures
|
Case Temperature
|
Displays the case temperature. The range is from -100 to 150 degrees Celsius.
|
Fiber Temperature
|
Displays the fiber temperature. The range is from -100 to 150 degrees Celsius.
|
Pump 1 Temperature
|
Displays the pump 1 temperature. The range is from -100 to 150 degrees Celsius.
|
Pump 2 Temperature
|
Displays the pump 2 temperature. The range is from -100 to 150 degrees Celsius.
|
Bus Voltages
|
Bus A Voltage
|
Displays the power bus A voltage. The range is from 0 to 999 V.
|
Bus B Voltage
|
Displays the power bus B voltage. The range is from 0 to 999 V.
|
B.4.8.5 Thresholds Tab
The Thresholds tab displays the threshold settings of the EDFA3.
Table B-26 Field Descriptions for the Thresholds Tab
Field
|
Description
|
Gain
|
Degrade High
|
Displays the degrade high threshold associated with the amplifier gain. The range is from 0 to 40 dB.
|
Degrade Low
|
Displays the degrade low threshold associated with the amplifier gain. The range is from 0 to 40 dB.
|
Gain
|
Displays the gain value. The range is from 0 to 40 dB.
|
Line 1 Tx Power
|
Degrade High
|
Displays the degrade high threshold associated with the amplifier output power related to the Line 1 Tx port. The range is from 0 to 40 dB.
|
Degrade Low
|
Displays the degrade low threshold associated with the amplifier output power related to the Line 1 Tx port. The range is from 0 to 40 dB.
|
Line 1 Output Power
|
Displays the amplifier output power related to the Line 1 Tx port. The range is from -60 to 25 dBm.
|
Fail Low
|
Displays the fail low threshold associated with the output power value related to the Line 1 Tx port. The range is from -10 to 14 dBm; the Cisco default is -6 dBm.
|
Line 1 Rx Power
|
Amplifier Input Power
|
Displays the amplifier input power value related to the Line 1 Rx port. The range is from -60 to 25 dBm.
|
Fail Low
|
Displays the fail low threshold associated with the input power value related to the Line 1 Rx port. The range is from -49 to 13 dBm; the Cisco default is 10 dBm.
|
Line 2 Rx Power
|
Laser 2 Input Power
|
Displays the mid-stage access input power value related to the Line 1 Rx port. The range is from -60 to 25 dBm.
|
Fail Low
|
Displays the fail low threshold associated with the mid-stage access input power related to the Line 2 Rx port. The range is from -49 to 15 dBm; the Cisco default is -33 dBm.
|
Gain Module Temperature
|
Temperature Max
|
Displays the maximum allowable case temperature threshold. The range is from 60 to 100 degrees Celsius; the Cisco default is 65 degrees Celsius.
|
Temperature Min
|
Displays the minimum allowable case temperature threshold. The range is from -10 to 30 degrees Celsius; the Cisco default is -5 degrees Celsius.
|
Case Temperature
|
Displays the case temperature. The range is from -100 to 150.
|
Bus Voltage
|
Bus Voltage Max
|
Displays the power bus A and B maximum voltage. The range is from 49 to 70 V; the Cisco default is 57 V.
|
Bus Voltage Min
|
Displays the power bus A and B minimum voltage. The range is from 0 to 47 V; the Cisco default is 40 V.
|
Bus A Voltage
|
Displays the power bus A voltage. The range is from 0.0 to 999.9 V.
|
Bus B Voltage
|
Displays the power bus B voltage. The range is from 0.0 to 999.9 V.
|
B.4.8.6 Alarm Behavior Tab
The Alarm Behavior tab allows you to enter, save, view, and update NE fault management attributes.
Table B-27 Field Descriptions for the Alarm Behavior Tab
Field
|
Description
|
Probable Cause
|
Displays the possible causes of the alarm.
|
Severity
|
Displays the alarm severity (Critical, Major, Minor, or Not Alarmed) and whether the alarm is service affecting (SA) or nonservice affecting (NSA).
|
B.4.8.7 SNMP Tab
The SNMP tab displays information about the SNMP Trap Destination table. Click Add Row to create a new trap destination; click Delete Row to delete an existing trap destination.
Table B-28 Field Descriptions for the SNMP Tab
Field
|
Description
|
IP Address
|
Displays the SNMP IP address.
|
UDP Port Number
|
Displays the trap destination UDP port.
|
Community Name
|
Displays the trap destination community name.
|
Version
|
Displays the SNMP version number.
|
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.9 ONS 15216 Active OADM NE Explorer
The ONS 15216 OADM NE Explorer displays information about the ONS 15216 100-GHz OADM NE.
Figure B-10 NE Explorer—ONS 15216 100-GHz OADM
The ONS 15216 100-GHz OADM NE Explorer contains the following tabs:
•
Identification Tab
•
Address Tab
•
DWDM Tab
•
Alarms Tab
•
Thresholds Tab
B.4.9.1 Identification Tab
The Identification tab displays identification information for the ONS 15216 100-GHz OADM NE.
Table B-29 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Wavelength(s)
|
Displays the number of wavelengths for this NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE.
|
Location Name
|
Displays the name of the location where the NE is installed.
|
NE Date and Time
|
Displays the date and time when the NE was installed.
|
B.4.9.2 Address Tab
The Address tab displays information about the NE network address.
Table B-30 Field Descriptions for the Address Tab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE. If the field does not apply to the NE, the label is grayed out and the value reads Not Applicable.
|
Gateway Address
|
Displays the gateway address of the NE. If the field does not apply to the NE, the label is grayed out and the value reads Not Applicable.
|
SNMP Community String
|
Displays the SNMP community string of the NE. If the field does not apply to the NE, the label is grayed out and the value reads Not Applicable.
|
GNE ID
|
Displays the GNE ID.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition associated with the selected NE.
|
B.4.9.3 DWDM Tab
The DWDM tab allows you to view, enter, update, and save the NE DWDM attributes.
Table B-31 Field Descriptions for the DWDM Tab
Field
|
Description
|
Channel Number
|
Displays the channels that can be added or dropped. Values are:
• 1-channel—West 1, East 1
• 2-channel—West 1, East 1, West 2, East 2
• 4-channel—West 1, East 1, West 2, East 2, West 3, East 3, West 4, East 4
|
Mode
|
Allows you to configure the NE DWDM mode. Values are:
• Setpoint (Cisco default)—The add channel power is set to the value of the Default Add Channel Power. Although the Default Add Channel Power can be set in any configuration, the add channel power is only equal to the Default Add Channel Power value in this mode.
• Off—To turn off an add channel, set the channel power to a very low value (for example, -35 dBm). No alarm will be triggered.
• Disable—When an add/drop channel is not in use, the channel should be configured in DISBABLE mode where no alarms will be triggered.
|
Default Add Channel Power
|
Displays the default power of the added channel in dBm. It is only available if you select Setpoint as the mode. Values must be from -29.0 to 3.0 in increments of 0.1.
|
InsLossAdd
|
Shows the calculated insertion loss for the add channel.
|
InsLossDrop
|
Shows the calculated insertion loss for the drop channel.
|
InsLossXpress
|
Shows the calculated insertion loss for the express/through channels.
|
Calculated Setpoint (CALCSETP)
|
The CALCSETP feature of the ONS 15216 OADM is a calculated value, and represents the OADMs recommended optical power level setting for a particular add channel. Following this recommendation when selecting the setpoint value for a particular add channel will allow the composite outgoing signal (composed of express channels and newly added channels) to be as flat as possible. The formula used for this calculation is CALCSETP = PWRDROP + ILDROP - ILTHRU.
|
B.4.9.4 Alarms Tab
The Alarms tab allows you to enter, save, view, and update NE dropped channel signal loss alarm attributes.
Table B-32 Field Descriptions for the Alarms Tab
Field
|
Description
|
Channel Number
|
Displays the channels that can be added or dropped. Values are:
• 1-channel—West 1, East 1
• 2-channel—West 1, East 1, West 2, East 2
• 4-channel—West 1, East 1, West 2, East 2, West 3, East 3, West 4, East 4
|
Drop Channel Signal Loss Alarm
|
Displays the current condition of the drop channel signal loss alarm. Values are:
• On—Enables the loss signal alarm of the drop channel.
• Off—Disables the loss signal alarm of the drop channel.
|
B.4.9.5 Thresholds Tab
The Thresholds tab allows you to enter, save, view, and update NE loss of signal and add/drop channel signal mismatch threshold attributes.
Table B-33 Field Descriptions for the Thresholds Tab
Field
|
Description
|
Channel Number
|
Displays the channels that can be added or dropped. Values are:
• 1-channel—West 1, East 1
• 2-channel—West 1, East 1, West 2, East 2
• 4-channel—West 1, East 1, West 2, East 2, West 3, East 3, West 4, East 4
|
Loss of Signal
|
Displays the signal loss threshold value. Valid values are -30.0 to 3.5 dBm in increments of 0.1 dBm.
|
Drop and Add Signal Mismatch
|
Displays the threshold value for the drop channel signal loss alarm. Valid values are 0.2 to 2.0 dB in increments of 0.1 dB. The Cisco default is 1.0 dB.
|
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.10 ONS 15216 Passive OADM NE Explorer
The ONS 15216 Passive OADM NE Explorer displays information about the ONS 15216 passive OADM NE. It contains an Identification tab.
B.4.10.1 Identification Tab
The Identification tab displays identification information for the ONS 15216 passive OADM NE.
Table B-34 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Wavelength(s)
|
Displays the number of wavelengths for this NE.
|
Product Name
|
Displays the name of the product. Displays 15216-MD16-2-BLUE for the blue version and 15216-MD16-2-RED for the red version. Displays Unknown if the product name is not known.
Note The information displayed in the Product Name field depends on the wavelength selected.
|
CLEI Code
|
Displays the CLEI code. Displays WMMFD00BRA for the blue version and WMMFE00BRA for the red version. Displays Unknown if the CLEI code is not known.
Note The information displayed in the CLEI Code field depends on the wavelength selected.
|
Serial Number
|
Displays the serial number of the NE. You can edit this field.
|
Location Name
|
Displays the name of the location where the NE is installed. You can edit this field.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition to which the NE belongs.
|

Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.4.11 ONS 15216 OSC Passive NE Explorer
The ONS 15216 Passive OSC NE Explorer displays information about the ONS 15216 passive OSC NE. It contains an Identification tab.
B.4.11.1 Identification Tab
The Identification tab displays the identification information for the ONS 15216 passive OSC NE.
Table B-35 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
NE Type
|
Displays the type of NE.
|
NE Version
|
Displays the software version of the NE.
|
Wavelength(s)
|
Displays the number of wavelengths for this NE.
|
Product Name
|
Displays the name of the product.
|
CLEI Code
|
Displays the CLEI code.
|
Serial Number
|
Displays the serial number of the NE. You can edit this field.
|
Location Name
|
Displays the name of the location where the NE is installed. You can edit this field.
|
Subnetwork ID
|
Displays the ID of the subnetwork to which the NE belongs.
|
Network Partition ID
|
Displays the ID of the network partition.
|
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.5 ONS 15302 and ONS 15305
The NE Explorer is not available for the ONS 15302 and ONS 15305. Equivalent functionality is provided through launching Cisco Edge Craft from CTM; choose Configuration > ONS 15302 or ONS 15305 > Launch Cisco Edge Craft.
Figure B-11 Cisco Edge Craft for the ONS 15305
B.6 ONS 15305 CTC NE Explorer
When you choose Configuration > NE Explorer for the ONS 15305, the window displayed by CTM consists of a tree on the left side and a properties pane on the right. The tree provides a hierarchical view and alarm status of the NE's physical shelves and slots. The properties pane shows information about the selected entity (NE or slot). See Node Properties Pane—ONS 15305 CTC for more information.
Figure B-12 ONS 15305 CTC NE Explorer
Note
If CTC is launched from the web browser for an ONS 15305 node, the CTC GUI might look different from when it is launched from CTM. This discrepancy occurs because the latest version of CTC (for NE releases supported by CTM) is packaged with CTM. If launched from a browser, the CTC software is retrieved from the NE itself, which might be a version different from that packaged with CTM.
When an NE Explorer is in autorefresh mode, all values of an entity that is being edited by the user are automatically refreshed. You will lose all of your changes unless you click the Apply button. To enable autorefresh, click the Refresh Data button in the NE Explorer.
B.6.1 Node Properties Pane—ONS 15305 CTC
The node properties pane displays information about the ONS 15305 CTC slot that is selected in the NE Explorer tree. The ONS 15305 CTC node properties pane contains the following tabs, some of which apply only to a specific NE version:
•
Shelf View Tab
•
Identification Tab
•
Network Tab
•
Protection Tab
•
DCC Tab
•
Alarm Tab
B.6.1.1 Shelf View Tab
The Shelf View tab displays a graphic of the ONS 15305 CTC that is selected in the NE Explorer tree. Moving the mouse pointer over the graphic of the NE, its shelves, slots, or cards displays the current alarms for the shelf, slot, or card. Double-clicking a slot or card displays the slot or card in the properties pane. The right-click menu allows you to reset or delete the card. For unprovisioned slots, the right-click menu allows you to add a card.
B.6.1.2 Identification Tab
The Identification tab displays information about the NE.
Table B-36 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
Software Version
|
Displays the current running version of the system software.
|
Contact
|
Displays the name of the node contact person and the phone number.
|
System Description
|
Displays a description of the NE.
|
TP Settings
|
Use TP Server
|
If checked, CTC uses a Simple Network Time Protocol (SNTP) server to set the date and time of the node. Using an SNTP server ensures that all ONS 15305 network nodes use the same date and time reference. The server synchronizes the node's time after power outages or software upgrades. If you check the Use TP Server check box, enter the server's IP address in the next field. If you do not use an SNTP server, complete the Time and Time Zone fields. The ONS 15305 CTC will use these fields for alarm dates and times.
|
TP Server
|
Displays the SNTP server IP address.
|
Location
|
Latitude
|
Allows you to set the latitude of the NE. Select North or South from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Longitude
|
Allows you to set the longitude of the NE. Select East or West from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Date and Time
|
Time
|
Displays the NE date and time.
|
Time Zone
|
Displays the time zone where the NE is located.
|
B.6.1.3 Network Tab
The Network tab displays information about the NE network address. The Network tab contains the following subtabs:
•
Address Subtab
•
Static Routes Subtab
•
OSPF Subtab
•
SNMP Subtab
B.6.1.3.1 Address Subtab
The Address subtab allows you to view and change information about the NE network address.
Table B-37 Field Descriptions for the Address Subtab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Default Router
|
Displays the IP address of the default router.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE.
|
MAC Address
|
Displays the ONS 15305 address as it is identified on the IEEE 802 MAC layer.
|
B.6.1.3.2 Static Routes Subtab
The Static Routes subtab allows you to view information about CTM and ONS 15305 CTC connectivity and create or delete static routes.
Table B-38 Field Descriptions for the Static Routes Subtab
Field
|
Description
|
Destination IP
|
Displays the IP address of the computer running CTM.
|
Subnet Mask
|
Displays the subnetwork mask.
|
Next Hop
|
Displays the IP address of the router port or the node IP address if the CTM computer is connected to the node directly.
|
Cost
|
Displays the number of hops between the ONS 15305 CTC and the computer.
|
B.6.1.3.3 OSPF Subtab
The OSPF subtab displays Open Shortest Path First (OSPF) information. OSPF is a link state Internet routing protocol.
Table B-39 Field Descriptions for the OSPF Subtab
Field
|
Description
|
Slot
|
Displays the slot number.
|
Port
|
Displays the port number.
|
DCC OSPF Area ID
|
Displays the number that identifies the ONS 15305 CTCs as a unique OSPF area. The OSPF area number can be from 0.0.0.0 to 255.255.255.255. The number must be unique to the LAN OSPF area.
|
LAN Port Area ID
|
Displays the OSPF area ID for the router port where the ONS 15305 CTC is connected. (This number is different from the DCC OSPF area ID.)
|
Router Priority
|
Displays the designated router for a subnet.
|
Hello Interval
|
Displays the number of seconds between OSPF hello packet advertisements sent by OSPF routers. Ten seconds is the Cisco default.
|
Dead Interval
|
Displays the number of seconds that will pass while an OSPF router's packets are not visible before its neighbors declare the router down. Forty seconds is the Cisco default.
|
Transit Delay
|
Displays the service speed. One second is the Cisco default.
|
Retransmit Interval
|
Displays the time that will elapse before a packet is resent. Five seconds is the Cisco default.
|
LAN Metric
|
Displays a cost for sending packets across the LAN. This value should always be lower than the DCC metric. Ten is the Cisco default.
|
B.6.1.3.4 SNMP Subtab
The SNMP subtab allows you to view SNMP information and create or delete SNMP trap destinations.
Table B-40 Field Descriptions for the SNMP Subtab
Field
|
Description
|
Allow SNMP Set
|
If checked, allows you to use SNMP management software with the ONS 15305 CTC.
|
IP Address
|
The IP address of the NMS.
|
Community Name
|
The SNMP community name.
Note The SNMP community string cannot be blank in CTM.
|
UDP Port
|
The UDP port for SNMP. The Cisco default UDP port is 162.
|
Trap Version
|
The trap version, either SNMP version 1 or version 2. See your NMS documentation to determine whether to use SNMP version 1 or version 2.
|
Relay A IP Address
|
The first ONS 15305 CTC to relay traps through. The IP address is appended to the base community string (to tell the first NE that is relaying the trap), the IP address, and port to forward the trap to. The second NE recognizes the IP address and strips it from the community string before forwarding the trap.
|
Relay A Community Name
|
The community name for the relay A node to use in the trap when forwarding it.
|
Relay B IP Address
|
The second ONS 15305 CTC to relay traps through.
|
Relay B Community Name
|
The community name for the relay B node to use in the trap when forwarding it.
|
Relay C IP Address
|
The third ONS 15305 CTC to relay traps through.
|
Relay C Community Name
|
The community name for the relay C node to use in the trap when forwarding it.
|
B.6.1.4 Protection Tab
The Protection tab contains the following subtabs:
•
Protection Groups Subtab
•
Operations Subtab
B.6.1.4.1 Protection Groups Subtab
The Protection Groups subtab displays a list of available protection groups and allows you to create, delete, and view protection groups.
Table B-41 Field Descriptions for the Protection Groups Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups. Click the Create or Delete button to create a new protection group or delete an existing one.
|
Selected Protection Group
|
Name
|
Modify the name of the selected protection group. The name can have up to 32 alphanumeric characters.
|
Type
|
View the protection type (1:1 [card], 1:N [card], Y Cable [port], or 1+1 [port]) of the selected protection group.
|
Protect Module
|
View the protect module if using 1+1 protection.
|
Available Entities
|
Displays a list of available entities. You can toggle between available and working entities.
|
Working Entities
|
Displays a list of working entities. You can toggle between working and available entities.
|
Bidirectional Switching
|
Click if you want both the transmit and the receive channels to switch if a failure occurs on one. This option is only available if you select 1+1 (port) type.
|
Revertive
|
If checked, the node reverts traffic to the working card or port after failure conditions stay corrected for the amount of time entered in Reversion Time. This option is not available if the 1:N (card) type has been selected.
|
Reversion Time
|
If Revertive is checked, choose the amount of time following failure condition correction after which the node should switch back to the working card or port. Use half-minute increments. This option is only available if you select 1:1 (card) type.
|
B.6.1.4.2 Operations Subtab
The Operations subtab displays the protection group operation information.
Table B-42 Field Descriptions for the Operations Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups.
|
Protection Group Details
|
Displays details about the selected protection groups and allows you to execute switch commands.
|
Switch Commands
|
Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
Inhibit Switching
|
Allows you to inhibit unlock switching, lock out switching, or lock on switching.
|
B.6.1.5 DCC Tab
The DCC tab allows you to configure the Data Communication Channel on the regeneration section and the multiplex section.
Table B-43 Field Descriptions for the DCC Tab
Field
|
Description
|
DccR
|
DCC-R Terminations
|
Displays the DCC termination on the regeneration section configured. The slot and port on which this type of termination is configured are displayed.
|
Admin State
|
Allows you to check and set the administrative state of the DCC termination. Values are In Service (IS) or Out of Service (OOS).
|
DccM
|
DCC-M Terminations
|
Displays the DCC termination on the multiplex section configured. The slot and port on which this type of termination is configured are displayed.
|
Admin State
|
Allows you to check and set the administrative state of the DCC termination. Values are In Service (IS) or Out of Service (OOS).
|
B.6.1.6 Alarm Tab
The Alarm tab allows you to change default alarm severities by creating unique alarm profiles for individual ONS 15310 CL and ONS 15310 MA nodes. The Alarm tab contains the Alarm Behavior subtab.
Note
The Alarm tab might contain default alarm profile entries for cards that are not supported by the ONS 15305 CTC. Therefore, you might see some alarms that do not apply to the NE type that you are provisioning.
B.6.1.6.1 Alarm Behavior Subtab
The Alarm Behavior subtab allows you to change default alarm severities by creating unique alarm profiles.
Table B-44 Field Descriptions for the Alarm Behavior Subtab
Field
|
Description
|
Alarm Profile
|
Choose a global alarm profile for the NE from the drop-down list.
|
Suppress Alarms
|
If checked, all alarms are suppressed.
|
Slot Number
|
Displays the location of the module.
|
Equipment Type
|
Displays the type of module in the slot.
|
Profile
|
Choose an alarm profile for the slot from the drop-down list.
|
Suppress Alarms
|
Indicates whether or not the alarms for the particular card are suppressed. If checked, all alarms are suppressed for the port.
|
B.7 ONS 15310 CL NE Explorer
When you choose Configuration > NE Explorer for the ONS 15310 CL, the window displayed by CTM consists of a tree on the left side and a properties pane on the right. The tree provides a hierarchical view and alarm status of the NE's physical shelves and slots. The properties pane shows information about the selected entity (NE or slot). See Node Properties Pane—ONS 15310 CL for more information.
Figure B-13 ONS 15310 CL NE Explorer
Note
If CTC is launched from the web browser for an ONS 15310 CL node, the CTC GUI might look different from when it is launched from CTM. This discrepancy occurs because the latest version of CTC (for NE releases supported by CTM) is packaged with CTM. If launched from a browser, the CTC software is retrieved from the NE itself, which might be a version different from that packaged with CTM.
When an NE Explorer is in autorefresh mode, all values of an entity that is being edited by the user are automatically refreshed. You will lose all of your changes unless you click the Apply button. To enable autorefresh, click the Refresh Data button in the NE Explorer.
B.7.1 Node Properties Pane—ONS 15310 CL
The node properties pane displays information about the ONS 15310 CL slot that is selected in the NE Explorer tree. The ONS 15310 CL node properties pane contains the following tabs, some of which apply only to a specific NE version:
•
Shelf View Tab
•
Identification Tab
•
Network Tab
•
DCC Tab
•
Timing Tab
•
Protection Tab
•
NE Defaults Tab
•
Security Tab
•
Alarm Tab
•
XC Utilization Tab
•
OSI Tab
B.7.1.1 Shelf View Tab
The Shelf View tab displays a graphic of the ONS 15310 CL that is selected in the NE Explorer tree. Moving the mouse pointer over the graphic of the NE, its shelves, slots, or cards displays the current alarms for the shelf, slot, or card. Double-clicking a slot or card displays the slot or card in the properties pane. The right-click menu allows you to reset or delete the card. For unprovisioned slots, the right-click menu allows you to add a card.
B.7.1.2 Identification Tab
The Identification tab displays information about the NE.
Table B-45 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
Software Version
|
Displays the current running version of the system software.
|
Contact
|
Displays the name of the node contact person and the phone number.
|
System Description
|
Displays a description of the NE.
|
SNTP Settings
|
Use NTP/SNTP Server
|
If checked, CTC uses a Simple Network Time Protocol (SNTP) server to set the date and time of the node. Using an SNTP server ensures that all ONS 15310 CL network nodes use the same date and time reference. The server synchronizes the node's time after power outages or software upgrades. If you check the Use NTP/SNTP Server check box, enter the server's IP address in the next field. If you do not use an SNTP server, complete the Time and Time Zone fields. The ONS 15310 CL will use these fields for alarm dates and times.
|
SNTP Server
|
Displays the SNTP server IP address.
|
Location
|
Latitude
|
Allows you to set the latitude of the NE. Select North or South from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Longitude
|
Allows you to set the longitude of the NE. Select East or West from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Date and Time
|
Time
|
Displays the NE date and time.
|
Time Zone
|
Displays the time zone where the NE is located.
|
Use Daylight Savings Time
|
If checked, Daylight Savings Time is observed.
|
AIS-V Insertion on STS-1 Signal Degrade - Path
|
Insert AIS-V on STS-1 SD-P
|
If checked, the NE inserts an AIS-V signal when it detects an STS-1 signal degrade.
|
SD-P BER
|
Select the signal degrade path bit error rate for AIS-V insertion.
|
B.7.1.3 Network Tab
The Network tab displays information about the NE network address. The Network tab contains the following subtabs:
•
Address Subtab
•
Static Routes Subtab
•
OSPF Subtab
•
OSPF Area Range Subtab
•
OSPF Virtual Links Subtab
•
SNMP Subtab
•
Firewall/Proxy Subtab
•
RIP Routing Table Subtab
•
RIP Subtab
•
Routing Table Subtab
•
Proxy Tunnels Subtab
•
Firewall Tunnels Subtab
B.7.1.3.1 Address Subtab
The Address subtab allows you to view and change information about the NE network address.
Table B-46 Field Descriptions for the Address Subtab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Default Router
|
Displays the IP address of the default router.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE.
|
MAC Address
|
Displays the ONS 15310 CL address as it is identified on the IEEE 802 MAC layer.
|
Forward DHCP Requests
|
If checked, forwards Dynamic Host Configuration Protocol (DHCP) requests to the IP address entered in the DHCP Server field. When the Forward DHCP Requests check box is unchecked, the field is read-only.
|
DHCP Server
|
Displays the IP address of the DHCP server.
|
B.7.1.3.2 Static Routes Subtab
The Static Routes subtab allows you to view information about CTM and ONS 15310 CL connectivity and create or delete static routes.
Table B-47 Field Descriptions for the Static Routes Subtab
Field
|
Description
|
Destination IP
|
Displays the IP address of the computer running CTM.
|
Subnet Mask
|
Displays the subnetwork mask.
|
Next Hop
|
Displays the IP address of the router port or the node IP address if the CTM computer is connected to the node directly.
|
Cost
|
Displays the number of hops between the ONS 15310 CL and the computer.
|
B.7.1.3.3 OSPF Subtab
The OSPF subtab displays Open Shortest Path First (OSPF) information. OSPF is a link state Internet routing protocol.
Table B-48 Field Descriptions for the OSPF Subtab
Field
|
Description
|
Slot
|
Displays the slot number.
|
Port
|
Displays the port number.
|
DCC OSPF Area ID
|
Displays the number that identifies the ONS 15310 CL NE as a unique OSPF area. The OSPF area number can be from 0.0.0.0 to 255.255.255.255. The number must be unique to the LAN OSPF area.
|
SDCC Metric
|
Sets a cost for sending packets across the Section Data Communications Channel (SDCC), which is used by OSPF routers to calculate the shortest path. This value should always be higher than the LAN metric. The Cisco default metric is 100. This value is normally unchanged.
|
OSPF Active on LAN
|
If checked, enables ONS 15310 CL OSPF topology to be advertised to OSPF routers on the LAN. Enable this field on ONS 15310 CL NEs that directly connect to OSPF routers.
|
LAN Port Area ID
|
Displays the OSPF area ID for the router port where the ONS 15310 CL is connected. (This number is different from the DCC OSPF area ID.)
|
Router Priority
|
Displays the designated router for a subnet.
|
Dead Interval
|
Displays the number of seconds that will pass while an OSPF router's packets are not visible before its neighbors declare the router down. Forty seconds is the Cisco default.
|
Retransmit Interval
|
Displays the time that will elapse before a packet is resent. Five seconds is the Cisco default.
|
Hello Interval
|
Displays the number of seconds between OSPF hello packet advertisements sent by OSPF routers. Ten seconds is the Cisco default.
|
Transit Delay
|
Displays the service speed. One second is the Cisco default.
|
LAN Metric
|
Displays a cost for sending packets across the LAN. This value should always be lower than the DCC metric. Ten is the Cisco default.
|
Authentication Type
|
Displays Simple Password if the router where the ONS 15310 CL is connected uses authentication. Otherwise, it displays No Authentication.
|
Authentication Key
|
Displays the OSPF key (password) if authentication is enabled.
|
Confirm Authentication Key
|
Retype the authentication key to confirm it.
|
B.7.1.3.4 OSPF Area Range Subtab
The OSPF Area Range subtab allows you to view information about OSPF area ranges and create or delete area ranges.
Table B-49 Field Descriptions for the OSPF Area Range Subtab
Field
|
Description
|
Range Address
|
Displays the area IP address for the ONS 15310 CL NE that resides within the OSPF area.
For example, if the ONS 15310 CL OSPF area includes nodes with IP addresses 10.10.20.100, 10.10.30.150, 10.10.40.200, and 10.10.50.250, the range address would be 10.10.0.0.
|
Range Area ID
|
Displays the OSPF area ID for the ONS 15310 CL. This is either the ID in the DCC OSPF area ID field or the ID in the area ID for LAN Port field.
|
Mask Length
|
Displays the subnet mask length.
|
Mask
|
Displays the subnet mask IP address.
|
Advertise
|
Indicates whether the OSPF range table is advertised.
|
B.7.1.3.5 OSPF Virtual Links Subtab
The OSPF Virtual Links subtab allows you to view information about OSPF virtual links and create or delete virtual links.
Note
You cannot create a new virtual link unless OSPF is active on the LAN.
Table B-50 Field Descriptions for the OSPF Virtual Links Subtab
Field
|
Description
|
Neighbor
|
Displays the router ID of the Area 0 router.
|
Transit Delay (sec)
|
Displays the service speed. One second is the Cisco default.
|
Retransmit Interval (sec)
|
Displays the time that will elapse before a packet is resent. Five seconds is the Cisco default.
|
Hello Interval (sec)
|
Displays the number of seconds between OSPF hello packet advertisements sent by OSPF routers. Ten seconds is the Cisco default.
|
Dead Interval (sec)
|
Displays the number of seconds that will pass while the packets of an OSPF router are not visible before its neighbors declare the router down. Forty seconds is the Cisco default.
|
Authentication Type
|
Displays the authentication type.
|
Authentication Key
|
Displays the authentication key.
|
B.7.1.3.6 SNMP Subtab
The SNMP subtab allows you to view SNMP information and create or delete SNMP trap destinations.
Table B-51 Field Descriptions for the SNMP Subtab
Field
|
Description
|
Allow SNMP Set
|
If checked, allows you to use SNMP management software with the ONS 15310 CL.
|
Allow SNMP Proxy
|
If checked, allows you to configure the ONS 15310 CL to proxy SNMP calls.
|
IP Address
|
The IP address of the NMS.
|
Community Name
|
The SNMP community name.
Note The SNMP community string cannot be blank in CTM. If a blank community string is required in CTC builds earlier than R4.6, you must set the blank community string in CTC.
|
UDP Port
|
The UDP port for SNMP. The Cisco default UDP port is 162.
|
Trap Version
|
The trap version, either SNMP version 1 or version 2. See your NMS documentation to determine whether to use SNMP version 1 or version 2.
|
Relay A IP Address
|
The first ONS 15310 CL to relay traps through. The IP address is appended to the base community string (to tell the first NE that is relaying the trap), the IP address, and port to forward the trap to. The second NE recognizes the IP address and strips it from the community string before forwarding the trap.
|
Relay A Community Name
|
The community name for the relay A node to use in the trap when forwarding it.
|
Relay B IP Address
|
The second ONS 15310 CL to relay traps through.
|
Relay B Community Name
|
The community name for the relay B node to use in the trap when forwarding it.
|
Relay C IP Address
|
The third ONS 15310 CL to relay traps through.
|
Relay C Community Name
|
The community name for the relay C node to use in the trap when forwarding it.
|
B.7.1.3.7 Firewall/Proxy Subtab
The Firewall/Proxy subtab allows you to use an NE as a proxy server or as a firewall.
Table B-52 Field Descriptions for the Firewall/Proxy Subtab
Field
|
Description
|
Gateway Settings
|
Enable Proxy Server on Port
|
If checked, the ONS 15310 CL serves as a proxy for connections between the CTM server and ONS 15310s that are DCC-connected to the proxy ONS 15310 CL. The CTM server establishes connections to DCC-connected nodes through the proxy node. The CTM server can connect to nodes that it cannot directly reach from the host on which it runs. The proxy server port number (read-only) is displayed following the Enable Proxy Server on Port field. The proxy server uses port number 1080.
If checked, the following radio buttons are enabled:
• External Network Element (ENE)—Enables the ONS 15310 CL to proxy as an ENE. Note that an alternate expansion for ENE is end network element.
• Gateway Network Element (GNE)—Enables the ONS 15310 CL to proxy as a GNE.
• Proxy-only—Enables proxy only.
If unchecked, the node does not proxy.
|
B.7.1.3.8 RIP Routing Table Subtab
The RIP Routing Table subtab allows you to view the Routing Information Protocol (RIP) routing table.
Table B-53 Field Descriptions for the RIP Routing Table Subtab
Field
|
Description
|
Destination
|
Displays the IP address of the destination network or host.
|
Mask
|
Displays the subnet mask used to reach the destination host or network.
|
Gateway
|
Displays the IP address of the gateway used to reach the destination network or host.
|
Cost
|
Displays the hop count metric. The valid range is from 1 to 15.
|
B.7.1.3.9 RIP Subtab
The RIP subtab allows you to view and configure RIP parameters.
Note
When you enable RIP, you must wait for approximately one minute for the default RIP address summary to become visible.
Note
When you disable RIP on the NE, all summary address entries in the Summary Address table will be deleted.
Table B-54 Field Descriptions for the RIP Subtab
Field
|
Description
|
RIP Active
|
Enable or disable RIP.
|
RIP Type
|
Select RIP version 1.0 or RIP version 2.0.
|
Metric
|
Select the hop count metric. The valid range is from 1 to 15.
|
Authentication Type
|
Select the authentication type.
|
Authentication Key
|
Enter the authentication key (password) if the authentication type is Simple Password.
|
Confirm Authentication Key
|
Retype the authentication key to confirm it.
|
RIP Address Summary
|
• Summary Address—Displays the summary address.
• Mask Length—Displays the subnet mask length.
• Cost—Displays the hop count metric. The valid range is from 1 to 15.
|
B.7.1.3.10 Routing Table Subtab
The Routing Table subtab allows you to view the OSPF routing table.
Table B-55 Field Descriptions for the Routing Table Subtab
Field
|
Description
|
Destination
|
Displays the IP address of the destination network or host.
|
Mask
|
Displays the subnet mask used to reach the destination host or network.
|
Gateway
|
Displays the IP address of the gateway used to reach the destination network or host.
|
Usage
|
Shows the number of times the listed route has been used.
|
Interface
|
Shows the ONS 15310 CL interface used to access the destination. Values are:
• cpm0—The ONS 15310 CL Ethernet interface (that is, the RJ-45 jack on the TCC+/TCC2 and the LAN 1 pins on the backplane)
• pdcc0—An SDCC interface (that is, an OC-N trunk card identified as the SDCC termination)
• lo0—A loopback interface
|
B.7.1.3.11 Proxy Tunnels Subtab
The Proxy Tunnels subtab allows you to configure source and destination information for proxy tunnels.
Table B-56 Field Descriptions for the Proxy Tunnels Subtab
Field
|
Description
|
Source Address
|
Specify the source IP address in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Source Mask
|
Specify the source subnetwork mask in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Destination Address
|
Specify the destination IP address in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Destination Mask
|
Specify the destination subnetwork mask in the source-destination pair for the tunnel that will be routed through the proxy server.
|
B.7.1.3.12 Firewall Tunnels Subtab
The Firewall Tunnels subtab allows you to configure source and destination information for firewall tunnels.
Table B-57 Field Descriptions for the Firewall Tunnels Subtab
Field
|
Description
|
Source Address
|
Specify the source IP address in the source-destination pair for the tunnel that will be routed through the firewall.
|
Source Mask
|
Specify the source subnetwork mask in the source-destination pair for the tunnel that will be routed through the firewall.
|
Destination Address
|
Specify the destination IP address in the source-destination pair for the tunnel that will be routed through the firewall.
|
Destination Mask
|
Specify the destination subnetwork mask in the source-destination pair for the tunnel that will be routed through the firewall.
|
B.7.1.4 DCC Tab
The DCC tab allows you to create, delete, and view SONET or SDH DCCs.
Table B-58 Field Descriptions for the DCC Tab
Field
|
Description
|
SDCC
|
SDCC Terminations
|
Displays the slot, port, and card type of an SDCC termination.
|
OSPF Disabled on Link
|
Check to prevent the advertisement of the OSPF routing table.
|
Foreign
|
A check mark indicates that the far-end node is a non-ONS node.
|
Foreign IP
|
Displays the foreign node IP address.
|
LAPD Config
|
If the SDCC is provisioned as OSI only, the following SDCC LAP-D parameters are displayed:
• AITS/UITS—Indicates the LAP-D acknowledgement type, either AITS (Acknowledged Information Transfer Service) or UITS (Unacknowledged Transfer Service).
• Network/User—Indicates the LAP-D frame command/response role, either Network or User.
• MTU—Shows the size of the maximum transfer unit (MTU). The range is from 512 to 1500 octets.
• T2000—Shows the time between SABME (Set Asynchronous Balanced Mode) frame transmission. The range is from 0.2 to 20 seconds.
• T203—Shows the maximum time between LAP-D frame exchanges. The range is from 4 to 120 seconds.
|
OSI SNPA
|
If the SDCC is provisioned for OSI, the following subnetwork point-of-attachment (SNPA) information is displayed:
• Router—Indicates the ONS router and NSAP address.
• Router State—Indicates whether the router is enabled or disabled.
|
Service State
|
Select the state of the termination:
• IS-NR—In Service-Normal.
• OOS-AU—Out of Service-Autonomous.
• OOS-MA—Out of Service-Management.
• OOS-AUMA—Out of Service-Autonomous and Management.
In addition, a secondary state provides additional information about the status of the entity. Values for secondary state are:
• MEA—Mismatch of equipment due to invalid equipment insertion.
• UEQ—Unequipped; there is nothing in the slot.
• UAS—Unassigned; the entity does not exist, has not been created, or has been deleted.
• SWDL—Software download in progress.
• MT—Maintenance, as per the Admin State change.
• AINS—Automatic in service.
• DSBLD—Traffic is disabled on the entity.
• LPBK—Port or connection has a loopback on it.
• FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment and ports in FLT state should be cleared as they transition. Transition states are listed in Table 11-10 on page 11-15.
See Table 11-10 on page 11-15 for the Service state-Secondary state possible values.
Note If the NE release does not support the Service state, this field shows N/A.
|
LDCC
|
LDCC Terminations
|
Displays the slot, port, and card type of an LDCC termination. Click Create to create a new LDCC termination; click Delete to delete the selected LDCC termination.
|
OSPF Disabled on Link
|
Check to prevent the advertisement of the OSPF routing table.
|
Foreign
|
A check mark indicates that the far-end node is a non-ONS node.
|
Foreign IP
|
Displays the foreign node IP address.
|
LAPD Config
|
If the SDCC is provisioned as OSI only, the following SDCC LAP-D parameters are displayed:
• AITS/UITS—Indicates the LAP-D acknowledgement type, either AITS (Acknowledged Information Transfer Service) or UITS (Unacknowledged Transfer Service).
• Network/User—Indicates the LAP-D frame command/response role, either Network or User.
• MTU—Shows the size of the maximum transfer unit (MTU). The range is from 512 to 1500 octets.
• T2000—Shows the time between SABME (Set Asynchronous Balanced Mode) frame transmission. The range is from 0.2 to 20 seconds.
• T203—Shows the maximum time between LAP-D frame exchanges. The range is from 4 to 120 seconds.
|
OSI SNPA
|
If the SDCC is provisioned for OSI, the following subnetwork point-of-attachment (SNPA) information is displayed:
• Router—Indicates the ONS router and NSAP address.
• Router State—Indicates whether the router is enabled or disabled.
|
Service State
|
Select the state of the LDCC termination:
• IS-NR—In Service-Normal
• OOS-AU—Out of Service-Autonomous
• OOS-MA—Out of Service-Management
• OOS-AUMA—Out of Service-Autonomous and Management
In addition, a secondary state provides additional information about the status of the entity. Values for secondary state are:
• MEA—Mismatch of equipment due to invalid equipment insertion
• UEQ—Unequipped; there is nothing in the slot
• UAS—Unassigned; the entity does not exist, has not been created, or has been deleted
• SWDL—Software download in progress
• MT—Maintenance, as per the Admin State change
• AINS—Automatic in service
• DSBLD—Traffic is disabled on the entity
• LPBK—Port or connection has a loopback on it
|
Create button
|
Allows you to create new terminations on SONET or SDH cards.
|
Edit button
|
Allows you to modify existing terminations on SONET or SDH cards.
|
Delete button
|
Allows you to delete the selected SDCC or LDCC.
|
B.7.1.5 Timing Tab
The Timing tab contains the following subtabs:
•
General Subtab
•
Reference List Subtab
•
Status Subtab
•
Timing Report Subtab
B.7.1.5.1 General Subtab
The General subtab displays general timing information.
Table B-59 Field Descriptions for the General Subtab
Field
|
Description
|
General Timing
|
Timing Mode
|
Set the node timing mode:
• External—The ONS 15310 CL derives its timing from a BITS source wired to the backplane pins.
• Line—Timing is derived from an OC-N card (non-DWDM nodes) or OSC card (DWDM nodes) that is optically connected to the timing node.
• Mixed—Timing is set to external and line timing references.
Caution  Mixed timing might cause timing loops; it is recommended that you use this mode with care.
|
SSM Message Set
|
Choose the sync status message (SSM) set level supported by your network. SSM is a SONET protocol that communicates information about the quality of the timing source. SSM messages are carried on the S1 byte of the SONET Line layer. They enable SONET devices to automatically select the highest quality timing reference and to avoid timing loops.
If a Generation 1 node receives a Generation 2 message, the message will be mapped down to the next available Generation 1. For example, an ST3E message becomes an ST3.
|
Revertive
|
If checked, the ONS 15310 CL reverts to a primary reference source after the conditions that caused it to switch to a secondary timing reference are corrected.
|
Reversion Time
|
Use the Reversion Time field to specify the time in half-minute increments.
|
Quality of RES
|
If your timing source supports the reserved S1 byte, you set the timing quality here. (Most timing sources do not use RES.) Qualities are displayed in descending quality order as ranges. For example, ST3 < RES < ST2 means the timing reference is higher than a Stratum 3 and lower than a Stratum 2.
|
BITS-IN-OUT Facility Type
|
In Facility Type
|
Provision the BITS In facility type.
|
Out Facility Type
|
Provisions the BITS Out facility type.
|
BITS Facilities 1
|
In State
|
Set the BITS In state to In Service (IS) or Out of Service (OOS). If Timing Mode is set to External or Mixed, set the BITS In State for BITS-1 and/or BITS-2 to IS (In Service) depending on whether one or both BITS input pin pairs on the backplane are connected to the external timing source. If Timing Mode is set to Line, set the BITS In State to OOS.
|
Coding
|
Set to the coding used by your BITS reference, either B8ZS or AMI.
|
Framing
|
Set to the framing used by your BITS reference, either Extended Super Frame (ESF), or Super Frame (SF). SSM is not available with Super Frame.
|
Sync Messaging
|
If checked, enables the Synchronization Status Message (SSM) for BITS In. (SSM is not available if Framing is set to Super Frame.)
|
Admin SSM
|
If the Sync Messaging check box is not checked, you can choose the SSM Generation 2 type from the drop-down list.
|
BITS OUT Facilities
|
Out State
|
Set the BITS reference to IS (In Service) or OOS (Out of Service). For nodes set to Line timing with no equipment timed through BITS Out, set State to OOS. For nodes using External timing or Line timing with equipment timed through BITS Out, set State to IS.
|
Coding
|
Set to the coding used by your BITS reference, either B8ZS or AMI.
|
Framing
|
Set to the framing used by your BITS reference, either ESF or SF (D4). SSM is not available with Super Frame.
|
AIS Threshold
|
If SSM is disabled or Super Frame is used, set the quality level where a node sends an alarm indication signal (AIS) from the BITS-1 Out and BITS-2 Out backplane pins. An AIS is raised when the optical source for the BITS reference falls to or below the SSM quality level defined in this field.
|
LBO
|
If you are timing an external device connected to the BITS Out pins, set the distance between it and the ONS 15310 CL. Options are 0-133 ft. (Cisco default), 134-266 ft., 267-399 ft., 400-533 ft., and 534-655 ft.
|
B.7.1.5.2 Reference List Subtab
The Reference List subtab provides timing reference information.
Table B-60 Field Descriptions for the Reference List Subtab
Field
|
Description
|
NE References
|
Allows you to define three timing references (Ref-1, Ref-2, Ref-3). The node uses Reference 1 unless a failure occurs on that reference, in which case, the node uses Reference 2. If that fails, the node uses Reference 3, which is typically set to the internal clock. This is the Stratum 3 clock provided on the TCC+. The options displayed depend on the Timing Mode setting.
• Timing Mode set to External—Options are BITS-1, BITS-2, and Internal.
• Timing Mode set to Line—Options are the node's working optical cards and Internal.
Select the cards/ports that are directly or indirectly connected to the node wired to the BITS source; that is, the node's trunk cards. Set Reference 1 to the trunk card that is closest to the BITS source. For example, if Slot 5 is connected to the node wired to the BITS source, select Slot 5 as Reference 1.
• Timing Mode set to Mixed—Both BITS and optical cards are available, allowing you to set a mixture of external BITS and optical trunk cards as timing references.
|
BITS-1 Out References
|
Allows you to define three timing references (Ref-1, Ref-2, Ref-3) for equipment wired to the BITS Out backplane pins. Normally, BITS Out is used with line nodes, so the options displayed are the working optical cards. BITS-1 Out is enabled as soon as BITS-1 facilities are placed in service.
|
B.7.1.5.3 Status Subtab
The Status subtab provides timing status information.
Note
If you change any values in the Status subtab and click Apply at the bottom of the screen, the values are not set. Instead, use the following buttons to apply changes:
•
Clear—Releases any existing switch request. For example, if you issue a Force Switch and then issue a Clear, the Force Switch request is released.
•
Manual Switch—Switches the timing reference from one source to another.
•
Force Switch—Switches the timing reference from one source to another. This request has a higher priority than the Manual Switch request.
Table B-61 Field Descriptions for the Status Subtab
Field
|
Description
|
NE Clock
|
NE Reference
|
Set the NE timing reference to internal, BITS-1, or BITS-2.
|
Status
|
Displays the status of the NE clock.
|
Operations
|
Execute a switch on the NE timing reference. Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
BITS-1 Out
|
BITS-1 Out
|
Set the BITS-1 out timing reference.
|
Status
|
Displays the status of the BITS-1 out timing reference.
|
Operations
|
Execute a switch on the BITS-1 out timing reference. Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
B.7.1.5.4 Timing Report Subtab
The Timing Report subtab summarizes the NE's current timing settings.
B.7.1.6 Protection Tab
The Protection tab contains the following subtabs:
•
Protection Groups Subtab
•
Operations Subtab
B.7.1.6.1 Protection Groups Subtab
The Protection Groups subtab displays a list of available protection groups and allows you to create, delete, and view protection groups.
Table B-62 Field Descriptions for the Protection Groups Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups. Click the Create or Delete button to create a new protection group or delete an existing one.
|
Selected Protection Group
|
Name
|
Modify the name of the selected protection group. The name can have up to 32 alphanumeric characters.
|
Type
|
View the protection type (1:1 [card], 1:N [card], Y Cable [port], or 1+1 [port]) of the selected protection group.
|
Protect Module
|
View the protect module if using 1+1 protection.
|
Available Entities
|
Displays a list of available entities. You can toggle between available and working entities.
|
Working Entities
|
Displays a list of working entities. You can toggle between working and available entities.
|
Bidirectional Switching
|
Click if you want both the transmit and the receive channels to switch if a failure occurs on one. This option is only available if you select 1+1 (port) type.
|
Revertive
|
If checked, the node reverts traffic to the working card or port after failure conditions stay corrected for the amount of time entered in Reversion Time. This option is not available if the 1:N (card) type has been selected.
|
Reversion Time
|
If Revertive is checked, choose the amount of time following failure condition correction after which the node should switch back to the working card or port. Use half-minute increments. This option is only available if you select 1:1 (card) type.
|
B.7.1.6.2 Operations Subtab
The Operations subtab displays the protection group operation information.
Table B-63 Field Descriptions for the Operations Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups.
|
Protection Group Details
|
Displays details about the selected protection groups and allows you to execute switch commands.
|
B.7.1.7 NE Defaults Tab
The NE Defaults tab displays a list of default thresholds for the ONS 15310 CL NE. You can edit NE defaults for the ONS 15310 CL R5.0 and later.
Table B-64 Field Descriptions for the NE Defaults Tab
Field
|
Description
|
Parameter
|
Lists the default NE parameter.
|
Value
|
Shows the default parameter value, and allows you to change the default.
|
Units
|
Lists the unit of measure that corresponds to the default NE parameter.
|
Range
|
Lists the possible range of values for the default NE parameter.
Note This field applies to the ONS 15310 CL R6.0 and later.
|
Side Effects
|
Lists any side effects that could occur as a result of changing the default NE parameter.
Note This field applies to the ONS 15310 CL R6.0 and later.
|
You can load different NE defaults using the NE Defaults Management window. See 4.5.12 Restoring NE Defaults, page 4-91.
B.7.1.8 Security Tab
The Security tab allows you to view and edit security features for the ONS 15310 CL NE. The Security tab contains the following subtabs:
•
Policy Subtab
•
Password Subtab
•
Access Subtab
•
RADIUS Server Subtab
•
Legal Disclaimer Subtab
B.7.1.8.1 Policy Subtab
The Policy subtab allows you to specify user security parameters.
Note
If the user is already logged in, any changes to the NE user type settings become applicable only when the user next logs in.
Table B-65 Field Descriptions for the Policy Subtab
Field
|
Description
|
Idle User Timeout
|
Each CTC or TL1 user can be idle during his or her login session for a specified amount of time before the CTC window is locked. The lockouts prevent unauthorized users from making changes. Higher-level users have shorter default idle periods and lower-level users have longer or unlimited default idle periods. The user idle period can be modified by a SuperUser.
Note A user already logged into the node is not affected by a change to the Idle User Timeout policy.
|
Retrieve
|
Set the idle user timeout for a CTC Retrieve user.
|
Maintenance
|
Set the idle user timeout for a CTC Maintenance user.
|
Provisioner
|
Set the idle user timeout for a CTC Provisioner user.
|
SuperUser
|
Set the idle user timeout for a CTC SuperUser user.
|
User Lockout
|
Manual Unlock by SuperUser
|
If checked, the CTC SuperUser user must manually unlock locked out CTC users. If unchecked, locked out CTC users are automatically unlocked after the lockout duration period elapses.
|
Lockout Duration
|
Set the lockout duration period for locked out CTC users. This field is only enabled if the Manual Unlock by SuperUser check box is unchecked.
|
Failed Logins Allowed
|
Set the number of failed logins before the CTC user is automatically locked out.
|
Other
|
Single Sessions per User
|
If checked, each CTC user can only launch one session at a time.
|
Disable Inactive User
|
If checked, inactive users are disabled automatically for the amount of time in the Inactive Duration field.
|
Inactive Duration
|
Specify the inactive duration in days. The range is from 1 to 90 days; the Cisco default is 45 days. A value of 0 implies inactive duration is disabled and invalid.
|
B.7.1.8.2 Password Subtab
The Password subtab allows you to specify user password security parameters.
Table B-66 Field Descriptions for the Password Subtab
Field
|
Description
|
Password Change
|
Prevent Reusing Last
|
Prevents setting a CTC user's current password to one of the most recent passwords. You can set the number of most recent passwords that cannot be reused. The range is from 1 to 10.
|
Disable Password Flipping
|
If checked, users are not allowed to change passwords for the number of days specified in the Can Change Password After field.
|
Can Change Password After
|
Enter the number of days that must elapse before the user can change the password.
|
Force Password Change After Assigned
|
If checked, during the first successful login, the user is forced to change the password.
|
Password Difference
|
Allows SuperUsers to specify the number of characters by which the new password of a user must differ from the old password, while performing a password change. The default value is 1. The range is from 1 to 5 characters.
|
Password Aging
|
Enable Password Aging
|
Check this check box to enable password aging.
|
Aging Period
|
Enter the aging period, in days, for Retrieve, Maintenance, Provisioner, and SuperUser CTC users. After the aging period expires, CTC users are forced to change their passwords.
|
Warning Period
|
Enter the warning period, in days, for Retrieve, Maintenance, Provisioner, and SuperUser CTC users. After the warning period expires, CTC users are warned that their passwords will soon expire.
|
B.7.1.8.3 Access Subtab
The Access subtab allows you to configure LAN and shell access to the NE.
Table B-67 Field Descriptions for the Access Subtab
Field
|
Description
|
LAN Access
|
LAN Access
|
Specify the type of LAN access allowed. Values allowed for the ONS 15310 CL are Front Only or No LAN Access.
Note After setting the LAN access to the backplane, the CTM client is unusable for 4 to 5 minutes.
|
Restore Timeout
|
This time period begins if No LAN Access is selected and all DCC connections are lost. If the time expires before a DCC is restored, LAN access is restored so that the node is not isolated. When the DCC comes back, LAN access returns to its specified settings. The range is from 0 (never) to 60 minutes; the Cisco default is 5 minutes.
|
Serial Craft Access (available for ONS 15310 CL NEs R6.0 and later)
|
Enable Craft Port
|
Check this check box to enable the craft port.
|
Shell Access
|
Shell Access on
|
Specify shell access on Telnet or SSH.
|
SSH Port
|
Indicates the SSH port number that will be used if the SSH radio button is selected.
|
Telnet Port
|
This is enabled if you selected the Telnet radio button. Enter the Telnet port number.
|
Use Standard Telnet Port
|
If checked, the standard Telnet port is used for Telnet access.
|
Shell Access (available for ONS 15310 CL NEs R6.0 and later)
|
Access State
|
Select the Shell access state from the pull-down menu. You can select Disable, Non-secure, or Secure.
|
SSH Port
|
Indicates the SSH port number that will be used.
|
Telnet Port
|
This is enabled if you selected the Non-secure access state. Enter the Telnet port number that will be used.
|
Use Standard Telnet Port
|
Check this check box to indicate that the standard Telnet port will be used.
|
Enable Shell Password
|
Indicates whether or not the Shell password is enabled.
Note You cannot enable the Shell password in CTM R7.2. Enabling and providing a Shell password is currently done in CTC.
|
EMS Access (available for ONS 15310 CL NEs R6.0 and later)
|
Access State
|
Select the EMS access state from the pull-down menu. You can select either Non-secure or Secure.
|
CORBA Listener Port
|
Select the port numbers for the CTX CORBA (IIOP) listener port and the CTX CORBA (SSLIOP) listener port. Select one of the following radio buttons:
• Default-Fixed—Assigns a default port number.
• Standard Constant—Port number for the CTX CORBA (IIOP) listener port will be 683. Port number for the CTX CORBA (SSLIOP) listener port will be 684.
• Other Constant—When selected, enter the port number that will be used.
|
TL1 Access (available for ONS 15310 CL NEs R6.0 and later)
|
Access State
|
Select the TL1 access state from the pull-down menu. You can select Disable, Non-secure, or Secure.
|
SNMP Access (available for ONS 15310 CL NEs R6.0 and later)
|
Access State
|
Select the SNMP access state from the pull-down menu. You can select either Disable or Non-secure.
|
Other
|
PM Clearing Privilege
|
Select the users privilege that allows clearing PM statistics for the NE.
|
B.7.1.8.4 RADIUS Server Subtab
The RADIUS Server subtab allows you to configure, create, modify, and delete RADIUS servers for the ONS 15310 CL R6.0 and later.
Table B-68 Field Descriptions for the RADIUS Server Subtab
Field
|
Description
|
Enable RADIUS Authentication
|
Check this check box to enable RADIUS authentication.
|
Enable RADIUS Accounting
|
Check this check box to enable RADIUS accounting. This is enabled if the Enable RADIUS Authentication check box is checked.
|
Enable the Node as the Final Authenticator When no RADIUS server is reachable
|
Select a row from the RADIUS Servers in Order of Authentication table; then, check this check box. This indicates that the RADIUS server that you selected will be the final authenticator when there are no more RADIUS servers that can be reached.
|
Create
|
Click this button to create a RADIUS server. See 8.4.2.1.1 Creating a RADIUS Server, page 8-51.
|
Edit
|
Click this button to modify an existing RADIUS server's information. See 8.4.2.1.2 Modifying a RADIUS Server, page 8-52.
|
Delete
|
Click this button to delete an existing RADIUS server. See 8.4.2.1.3 Deleting a RADIUS Server, page 8-52.
|
Move Up/Move Down
|
Select the Move Up and Move Down buttons to reorder the list of RADIUS servers in the RADIUS Servers in Order of Authentication table.
|
RADIUS Servers in Order of Authentication
|
IP Address
|
Displays the IP address of the RADIUS server.
|
Shared Secret
|
Displays a text string that serves as a password between a RADIUS client and RADIUS server.
|
Authentication Port
|
Displays the authentication port number of the RADIUS server. Default access is through port number 1812.
|
Accounting Port
|
Displays the accounting port number of the RADIUS server. Default access is through port number 1813.
|
B.7.1.8.5 Legal Disclaimer Subtab
The Legal Disclaimer subtab allows you to edit the NE's advisory message and preview the disclaimer.
Table B-69 Field Descriptions for the Legal Disclaimer Subtab
Subtab
|
Description
|
Advisory Message
|
The existing message is a default, noncustomer-specific disclaimer. If you want to edit this statement with specifics for your company, you can change the text. You can also use the following HTML commands to format the text:
<b> Begins boldface font
</b> Ends boldface font
<center> Aligns type in the center of the window
</center> Ends the center alignment
<font=n, where n = point size> Changes the font to the new size
</font> Ends the font size command
<p> Creates a line break
<sub> Begins subscript
</sub> Ends subscript
<sup> Begins superscript
</sup> Ends superscript
<u> Starts underline
</u> Ends underline
|
Preview
|
Allows you to view the advisory message before saving it.
|
B.7.1.9 Alarm Tab
The Alarm tab allows you to change default alarm severities by creating unique alarm profiles for individual ONS 15310 CL nodes. The Alarm tab contains the following subtabs:
•
Profile Subtab
•
Alarm Behavior Subtab
Note
The Alarm tab might contain default alarm profile entries for cards that are not supported by the Cisco ONS 15310. Therefore, you might see some alarms that do not apply to the NE type that you are provisioning.
B.7.1.9.1 Profile Subtab
The Profile subtab allows you to select, create, or delete alarm profiles.
Table B-70 Field Descriptions for the Profile Subtab
Field
|
Description
|
Alarm Profile Name
|
Choose an alarm profile for the NE from the drop-down list. Click Create to create a new alarm profile for the NE. Click Delete to delete an alarm profile from the NE.
|
Condition
|
Displays the alarm condition.
|
Severity
|
Displays the alarm severity.
|
B.7.1.9.2 Alarm Behavior Subtab
The Alarm Behavior subtab allows you to change default alarm severities by creating unique alarm profiles.
Table B-71 Field Descriptions for the Alarm Behavior Subtab
Field
|
Description
|
Alarm Profile
|
Choose a global alarm profile for the NE from the drop-down list.
|
Suppress Alarms
|
If checked, all alarms are suppressed.
|
Slot Number
|
Displays the location of the module.
|
Equipment Type
|
Displays the type of module in the slot.
|
Profile
|
Choose an alarm profile for the slot from the drop-down list.
|
Suppress Alarms
|
Indicates whether or not the alarms for the particular card are suppressed. If checked, all alarms are suppressed for the port.
|
B.7.1.10 XC Utilization Tab
The XC Utilization tab allows you to view a summary of the percentage of XTC cross-connect resources used by circuits that traverse or terminate at an ONS 15310 CL.
Table B-72 Field Descriptions for the XC Utilization Tab
Field
|
Description
|
STS-1 Matrix
|
Provides the percentage of the XC cross-connect STS-1 paths resources that are used.
|
VT Matrix Ports
|
Provides the percentage of the XTC cross-connect VT matrix ports that are used. Each port is one STS in size, and each can transport 28 VT1.5s. 24 VT matrix ports are available.
|
VT Matrix
|
Provides the percentage of the VT matrix resources that are used. 672 are available, which is the number of VT matrix ports (24) multiplied by the number of VT1.5s in an STS (28).
|
B.7.1.11 OSI Tab
Note
The OSI tab is supported only for the ONS 15310 CL R6.0 and later.
The OSI tab allows you to provision ONS 15310 CL Open System Interconnection (OSI) parameters. It contains the following subtabs:
•
Main Setup Subtab
•
TARP-Config Subtab
•
TARP-TDC Subtab
•
TARP-MAT Subtab
•
Routers-Setup Subtab
•
Subnets Subtab
•
Tunnels Subtab
•
IS-IS RIB Subtab
•
ES-IS RIB Subtab
B.7.1.11.1 Main Setup Subtab
The Main Setup subtab allows you to provision the OSI Network Entity Title (NET) address and the OSI routing mode.
Table B-73 Field Descriptions for the Main Setup Subtab
Field
|
Description
|
Main Network Entity Title
|
Displays the node NET. The NET is used in OSI networks to identify the node to the end system (ES) or intermediate system (IS).
|
End System
|
Provisions the node as an OSI End System (ES). ESs send End System Hello (ESH) messages regularly to announce their presence to neighboring ISs and ESs. For the ONS 15310 CL, End System is the Cisco default.
|
Intermediate System Level 1
|
Provisions the node as an OSI Intermediate System (IS). ISs send Intermediate System Hello (ISH) messages regularly to announce their presence to neighboring ISs and ESs.
|
Intermediate System Level 1/Level 2
|
The ONS 15310 CL performs all IS functions. It communicates with other IS and ES nodes within an OSI area and broadcasts ISHs to IS nodes in other areas to which it is connected.
|
Node Routing Mode
|
L1 LSP Buffer Size
|
Sets the Level 1 Link State Protocol (LSP) data unit buffer size. The Cisco default 512.
|
L2 LSP Buffer Size
|
Sets the Level 2 Link State Protocol (LSP) data unit buffer size. The Cisco default 512.
|
B.7.1.11.2 TARP-Config Subtab
The TARP Config subtab allows you to provision the TID Address Resolution protocol (TARP). TARP is used when TL1 TIDs must be translated to an NSAP address. During the TID-to-NSAP translation, the TID is mapped to a NET; then, the NSAP is derived from the NET based on the NSAP selector value.
Table B-74 Field Descriptions for the TARP-Config Subtab
Field
|
Description
|
TARP PDUs L1 Propagation
|
If checked (default), TARP Type 1 PDUs received by the node that are not excluded by the loop detection buffer are propagated to other NEs within the OSI Level 1 area. Type 1 PDUs request a protocol address that matches a target TID within a Level1 routing area. The propagation does not occur if the NE is the target of the Type 1 PDU and the PDUs are not propagated to the NE from which the PDU was received.
Note This parameter is not used when the node is set to End System.
|
TARP PDUs Origination
|
If checked (default), the node performs all TARP configuration functions, including:
• TID-to-NSAP resolution requests
• NSAP-to-TID requests
• TARP address changes
Note TARP Echo and NSAP to TID are not supported.
|
L2 TARP Data Cache
|
If checked (default), the TIDs and NSAPs are added to the TDC before the node propagates the requests to other NEs.
Note This parameter is designed for IS Level 1/Level 2 nodes that are connected to other IS Level 1/Level 2 nodes. Enabling the parameter for IS Level 1 nodes is not recommended.
|
LAN TARP Storm Suppression
|
If checked (default), enables the TARP storm suppression to prevent redundant TARP PDUs from being propagated across the network.
|
Type 4 PDU Delay
|
Sets the amount of time that will pass before the Type 4 PDU is generated. The Cisco default value is 60 seconds. The range is from 0 to 255 seconds.
|
TARP PDUs L2 Propagation
|
If checked (default), TARP Type 2 PDUs received by the node that are not excluded by the loop detection buffer are propagated to other NEs within the OSI Level 2 area. Type 2 PDUs request a protocol address that matches a target TID within a Level 2 routing area. The propagation occurs if the NE is the not the target of the Type 2 PDU and the PDUs are not propagated to the NE from which the PDU was received.
|
L1 TARP Data Cache
|
If checked, the node maintains a TARP data cache (TDC). The TDC is a database of TID to NSAP pairs created from TARP Type 3 PDUs received by the node. TARP 3 PDUs are responses to Type 1 and Type 2 PDUs and modified by TARP Type 4 PDUs (TID to NSAP updates or corrections).
|
LDB
|
If checked, enables the TARP loop detection buffer (LDB). The LDB prevents TARP PDUs from being sent more than once on the same subnet.
|
Send Type 4 PDU on Startup
|
If checked, a TARP Type 4 PDU is originated during the initial ONS 15310 CL startup. Type 4 PDUs indicate a TID or NSAP change has occurred at the NE. This is disabled by default.
|
Timers
|
LDB Entry
|
Sets the TARP LDB timer. The LDB buffer time is assigned to each LDB entry for which the TARP sequence number is zero. The Cisco default is 5 minutes. The range is from 1 to 10 minutes.
|
T1 Timer
|
Sets the amount of time to wait for response to a Type 1 Request PDU. Type 1 requests seek a specific NE TID within an OSI Level 1 area. The Cisco default is 15 seconds. The range is from 0 to 3600 seconds.
|
T3 Timer
|
Sets the amount of time to wait for an address resolution request. The Cisco default is 40 seconds. The range is from 0 to 3600 seconds.
|
LDB Flush
|
Sets the frequency period for flushing the LDB. The Cisco default is 5 minutes. The range is from 0 to 1440 minutes.
|
T2 Timer
|
Sets the amount of time to wait for a Type 2 Request PDU. TARP Type 2 requests seek a specific NE TID within an OSI Level 1 area. The Cisco default is 25 seconds. The range is from 0 to 3600 seconds.
|
T4 Timer
|
Sets the amount of time to wait for an error recovery. The timer begins after the T2 timer expires without successfully finding the NE TID. The Cisco default is 20 seconds. The range is from 0 to 3600 seconds.
|
B.7.1.11.3 TARP-TDC Subtab
Table B-75 Field Descriptions for the TARP-TDC Subtab
Field
|
Description
|
Add Static Entry button
|
Click this button to statically link a TID to an NSAP or NET.
|
Delete Selected Entry button
|
Deletes the selected TID to NSAP/NET static entry.
|
TID to NSAP button
|
Click this button to query the network for an NSAP that matches a TID.
|
Flush Dynamic Entries button
|
Click this button to delete all dynamically generated TDC entries.
|
TID
|
Target ID that is statistically linked to an NSAP or NET. For ONS nodes, the TID is the node name.
|
NSAP/NET
|
The NSAP that is statistically linked to the TID.
|
Type
|
Indicates how the TARP data cache entry was created. It can be either:
• Dynamic—The entry was created through the TARP propagation process.
• Static—The entry was manually created and is a static entry.
|
B.7.1.11.4 TARP-MAT Subtab
The TARP-MAT subtab allows you to manually provision a TARP adjacency.
Table B-76 Field Descriptions for the TARP-MAT Subtab
Field
|
Description
|
Level
|
Sets the TARP Type Code that will be sent.
• Level 1—Indicates that the manual area adjacency is within the same area as the node. The entry generates Type 1 PDUs.
• Level 2—Indicates that the manual area adjacency is in an area different from the node. The entry generates Type 2 PDUs.
|
NSAP
|
The NSAP address of the node at the other end of the TARP manual adjacency.
|
Add
|
Click this button to create a TARP manual area adjacency.
|
Remove
|
Click this button to delete the selected TID to NSAP/NET static entry.
|
B.7.1.11.5 Routers-Setup Subtab
The Routers-Setup subtab allows you to view and manage OSI virtual routers.
Table B-77 Field Descriptions for the Routers-Setup Subtab
Field
|
Description
|
Router Number
|
Displays the virtual router number. Only one router is available on the ONS 15310 CL.
|
System ID
|
Displays the NSAP system ID of the virtual router. For the primary router (Router 1), n = 0.
|
Status
|
Indicates the virtual router status. Select Enabled or Disabled from the drop-down menu.
Note Router 1 must be enabled before additional routers can be enabled.
|
Primary Area Address
|
Indicates the primary manual area address. For Router 1, this is the main NET for the node; that is, the NSAP without the system ID and selector (set to 00) fields.
|
Manual Area Address 1
|
Indicates the address of any additional manual areas that are created.
Note An OSI area allows up to two additional manual areas in addition to the primary manual area.
|
Manual Area Address 2
|
Indicates the address of any additional manual areas that are created.
Note An OSI area allows up to two additional manual areas in addition to the primary manual area.
|
B.7.1.11.6 Subnets Subtab
The Subnets subtab allows you to view and manage OSI subnetwork point-of-attachment parameters. The parameters are initially provisioned when you enable a subnet on an SDCC, LDCC, GCC, OSC, or LAN interface.
Table B-78 Field Descriptions for the Subnets Subtab
Field
|
Description
|
Enable LAN Subnet
|
(Router 1 only). Enables OSI over the LAN; that is, it activates the IS-IS protocol on the LAN so OSI traffic is enabled on the LAN.
|
Edit
|
Click Edit to modify subnet parameters.
|
Disable LAN Subnet
|
(Router 1 only). Disables OSI over the LAN if it has been enabled.
|
Slot/Port
|
The subnet slot and port.
|
Router Number
|
The OSI virtual router where the subnet (SDCC, LDCC, GCC, or OSC) is provisioned.
|
Type
|
The interface where the subnet is provisioned: SDCC, LDCC, GCC, OSC, or LAN.
|
Protocol
|
The data link protocol that is provisioned for the subnet. It can be:
• Point to Point Protocol (PPP)
• Link Access Protocol on the D channel (LAP-D)
• 802.3 for LAN subnets
|
ISH
|
The Intermediate System Hello (ISH) PDU propagation frequency. Intermediate system NEs send ISHs to other ESs and ISs to inform them about the NETs they serve. The Cisco default is 10 seconds. The range is from 10 to 1000 seconds.
|
ESH
|
The End System Hello (ESH) PDU propagation frequency. End system NEs transmit ESHs to inform other ESs and ISs about the NSAPs they serve. The Cisco default is 10 seconds. The range is from 10 to 1000 seconds.
|
IIH
|
The Intermediate System-to-Intermediate System Hello (IIH) PDU propagation frequency. The IS-IS Hello PDUs establish and maintain adjacencies between ISs. The Cisco default is 3 seconds. The range is from 1 to 600 seconds.
|
DisPriority
|
The designated intermediate system (DIS) priority. In IS-IS networks, one router is elected as the DIS. For Cisco routers, the DIS priority is 64.
|
IS-IS Cost
|
The cost for sending packets on the subnet. This is used by OSPF routers to calculate the shortest path. The Cisco default value is 20.
|
B.7.1.11.7 Tunnels Subtab
The Tunnels subtab allows you to view, create, edit, and delete Generic Routing Encapsulation (GRE) and Cisco tunnels. GRE tunnels encapsulate one network protocol for transfer across another network layer. Within a mixed TCP/IP and OSI network, GRE tunnels tunnel IP traffic over an OSI NE and OSI traffic over an IP NE.
Table B-79 Field Descriptions for the Tunnels Subtab
Field
|
Description
|
IP Address
|
Displays the IP address of the GRE destination CTM or CTC computer.
|
NetMask Address
|
Displays the IP address subnet mask of the destination CTM or CTC computer.
|
NSAP Address
|
The destination NE NSAP address. The NSAP selector (last two NSAP characters) must be 2f (GRE tunnel) or cc (proprietary Cisco tunnel), depending on which tunnel type you want to create. The Cisco proprietary tunnel is slightly more efficient than the GRE tunnel because it does not add an encapsulation header for each IP packet, while the GRE tunnel adds a small header to the packets. The two tunnel types are incompatible.
Note Most Cisco routers support the Cisco tunnel, while only a few support both GRE and Cisco IP tunnels.
|
OSPF Metric
|
Displays the cost for sending packets across the GRE tunnel. Cost is used by OSPF routers to calculate the shortest path.
|
Create
|
Click Create to create a new GRE tunnel route.
|
Edit
|
Click Edit to edit an existing GRE tunnel.
|
Delete
|
Click Delete to delete an existing GRE tunnel.
|
B.7.1.11.8 IS-IS RIB Subtab
The IS-IS RIB subtab allows you to view the Intermediate System-to-Intermediate System protocol routing information base. IS-IS is an OSI link-state hierarchical routing protocol that floods the network with link-state information that enables the NEs to build a complete and consistent picture of a network topology.
Table B-80 Field Descriptions for the IS-IS RIB Subtab
Field
|
Description
|
Router Number
|
Displays the virtual router number. Only one router is available on the ONS 15310 CL.
|
Subnet Type
|
Indicates the OSI subnetwork point-of-attachment type used to access the destination address. It includes SDCC, LDCC, GCC, OSC, and LAN.
|
Destination Address
|
Displays the Network Service Access Point (NSAP).
|
MAC Address
|
Displays the NE's MAC address for destinations that are accessed by the LAN subnets.
|
B.7.1.11.9 ES-IS RIB Subtab
The ES-IS RIB subtab allows you to view the End System-to-Intermediate System (ES-IS) protocol routing information base (RIB). ES-IS is an OSI protocol that defines how end systems (hosts) and intermediate systems (routers) learn about each other.
Table B-81 Field Descriptions for the ES-IS RIB Subtab
Field
|
Description
|
Router Number
|
Displays the virtual router number. Only one router is available on the ONS 15310 CL.
|
Subnet Type
|
Indicates the OSI subnetwork point-of-attachment type used to access the destination address. It includes SDCC, LDCC, GCC, OSC, and LAN.
|
Destination Address
|
Displays the Network Service Access Point (NSAP) of the destination ES.
|
MAC Address
|
Displays the NE's MAC address for destinations that are accessed by the LAN subnets.
|
Note
See Table 1-20 on page 1-44 for the descriptions of the actions that can be performed using the action buttons at the bottom of the window.
B.8 ONS 15310 MA NE Explorer
When you choose Configuration > NE Explorer for the ONS 15310 MA, the window displayed by CTM consists of a tree on the left side and a properties pane on the right. The tree provides a hierarchical view and alarm status of the NE's physical shelves and slots. The properties pane shows information about the selected entity (NE or slot). See Node Properties Pane—ONS 15310 MA for more information.
Figure B-14 ONS 15310 MA NE Explorer
Note
If CTC is launched from the web browser for an ONS 15310 MA node, the CTC GUI might look different from when it is launched from CTM. This discrepancy occurs because the latest version of CTC (for NE releases supported by CTM) is packaged with CTM. If launched from a browser, the CTC software is retrieved from the NE itself, which might be a version different from that packaged with CTM.
When an NE Explorer is in autorefresh mode, all values of an entity that is being edited by the user are automatically refreshed. You will lose all of your changes unless you click the Apply button. To enable autorefresh, click the Refresh Data button in the NE Explorer.
B.8.1 Node Properties Pane—ONS 15310 MA
The node properties pane displays information about the ONS 15310 MA slot that is selected in the NE Explorer tree. The ONS 15310 MA node properties pane contains the following tabs, some of which apply only to a specific NE version:
•
Shelf View Tab
•
Identification Tab
•
Network Tab
•
DCC Tab
•
Timing Tab
•
Protection Tab
•
NE Defaults Tab
•
Security Tab
•
Alarm Tab
•
XC Utilization Tab
•
OSI Tab
•
Alarm Extenders Tab
•
Orderwire Tab
B.8.1.1 Shelf View Tab
The Shelf View tab displays a graphic of the ONS 15310 MA that is selected in the NE Explorer tree. Moving the mouse pointer over the graphic of the NE, its shelves, slots, or cards displays the current alarms for the shelf, slot, or card. Double-clicking a slot or card displays the slot or card in the properties pane. The right-click menu allows you to reset or delete the card. For unprovisioned slots, the right-click menu allows you to add a card.
B.8.1.2 Identification Tab
The Identification tab displays information about the NE.
Table B-82 Field Descriptions for the Identification Tab
Field
|
Description
|
NE ID
|
Displays the ID of the NE from the Domain Explorer.
|
Description
|
Displays the description of the NE from the Domain Explorer.
|
NE Model
|
Displays the NE model type.
|
Software Version
|
Displays the current running version of the system software.
|
Contact
|
Displays the name of the node contact person and the phone number.
|
System Description
|
Displays a description of the NE.
|
SNTP Settings
|
Use NTP/SNTP Server
|
If checked, CTC uses a Simple Network Time Protocol (SNTP) server to set the date and time of the node. Using an SNTP server ensures that all ONS 15310 MA network nodes use the same date and time reference. The server synchronizes the node's time after power outages or software upgrades. If you check the Use NTP/SNTP Server check box, enter the server's IP address in the next field. If you do not use an SNTP server, complete the Time and Time Zone fields. The ONS 15310 MA will use these fields for alarm dates and times.
|
SNTP Server
|
Displays the SNTP server IP address.
|
Location
|
Latitude
|
Allows you to set the latitude of the NE. Select North or South from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Longitude
|
Allows you to set the longitude of the NE. Select East or West from the drop-down list; then, enter the degrees and minutes (or click the up and down arrows to increase or decrease each by 1 unit).
|
Date and Time
|
Time
|
Displays the NE date and time.
|
Time Zone
|
Displays the time zone where the NE is located.
|
Use Daylight Savings Time
|
If checked, Daylight Savings Time is observed.
|
AIS-V Insertion on STS-1 Signal Degrade - Path
|
Insert AIS-V on STS-1 SD-P
|
If checked, the NE inserts an AIS-V signal when it detects an STS-1 signal degrade.
|
SD-P BER
|
Select the signal degrade path bit error rate for AIS-V insertion.
|
Voltage Thresholds
|
ELWBATVG
|
Allows you to set the monitor value for extreme low battery voltage (ELWBATVG) in volts direct current (VDC).
|
LWBATVG
|
Allows you to set the monitor value for low battery voltage (LWBATVG) in VDC.
|
HIBATVG
|
Allows you to set the monitor value for high battery voltage (HIBATVG) in VDC.
|
EHIBATVG
|
Allows you to set the monitor value for extreme high battery voltage (EHIBATVG) in VDC.
|
Current Voltage Environment
|
Shows the current voltage environment (48 volts for SONET; 60 volts for SDH).
|
B.8.1.3 Network Tab
The Network tab displays information about the NE network address. The Network tab contains the following subtabs:
•
Address Subtab
•
Static Routes Subtab
•
OSPF Subtab
•
OSPF Area Range Subtab
•
OSPF Virtual Links Subtab
•
SNMP Subtab
•
Firewall/Proxy Subtab
•
RIP Routing Table Subtab
•
RIP Subtab
•
Routing Table Subtab
•
Proxy Tunnels Subtab
•
Firewall Tunnels Subtab
B.8.1.3.1 Address Subtab
The Address subtab allows you to view and change information about the NE network address.
Table B-83 Field Descriptions for the Address Subtab
Field
|
Description
|
IP Address
|
Displays the IP address of the NE.
|
Default Router
|
Displays the IP address of the default router.
|
Subnet Mask
|
Displays the subnetwork mask ID of the NE.
|
MAC Address
|
Displays the ONS 15310 MA address as it is identified on the IEEE 802 MAC layer.
|
Forward DHCP Requests
|
If checked, forwards Dynamic Host Configuration Protocol (DHCP) requests to the IP address entered in the DHCP Server field. When the Forward DHCP Requests check box is unchecked, the field is read-only.
|
DHCP Server
|
Displays the IP address of the DHCP server.
|
B.8.1.3.2 Static Routes Subtab
The Static Routes subtab allows you to view information about CTM and ONS 15310 MA connectivity and create or delete static routes.
Table B-84 Field Descriptions for the Static Routes Subtab
Field
|
Description
|
Destination IP
|
Displays the IP address of the computer running CTM.
|
Subnet Mask
|
Displays the subnetwork mask.
|
Next Hop
|
Displays the IP address of the router port or the node IP address if the CTM computer is connected to the node directly.
|
Cost
|
Displays the number of hops between the ONS 15310 MA and the computer.
|
B.8.1.3.3 OSPF Subtab
The OSPF subtab displays Open Shortest Path First (OSPF) information. OSPF is a link state Internet routing protocol.
Table B-85 Field Descriptions for the OSPF Subtab
Field
|
Description
|
Slot
|
Displays the slot number.
|
Port
|
Displays the port number.
|
DCC OSPF Area ID
|
Displays the number that identifies the ONS 15310 MA as a unique OSPF area. The OSPF area number can be from 0.0.0.0 to 255.255.255.255. The number must be unique to the LAN OSPF area.
|
SDCC Metric
|
Sets a cost for sending packets across the Section Data Communications Channel (SDCC), which is used by OSPF routers to calculate the shortest path. This value should always be higher than the LAN metric. The Cisco default metric is 100. This value is normally unchanged.
|
LDCC Metric
|
Sets a cost for sending packets across the LDCC, which is used by OSPF routers to calculate the shortest path. This value should always be higher than the LAN metric. This value is normally unchanged.
|
OSPF on LAN
|
OSPF Active on LAN
|
If checked, enables ONS 15310 MA OSPF topology to be advertised to OSPF routers on the LAN. Enable this field on ONS 15310 MA NEs that directly connect to OSPF routers.
|
LAN Port Area ID
|
Displays the OSPF area ID for the router port where the ONS 15310 MA is connected. (This number is different from the DCC OSPF area ID.)
|
Router Priority
|
Displays the designated router for a subnet.
|
Dead Interval
|
Displays the number of seconds that will pass while an OSPF router's packets are not visible before its neighbors declare the router down. Forty seconds is the Cisco default.
|
Retransmit Interval
|
Displays the time that will elapse before a packet is resent. Five seconds is the Cisco default.
|
Hello Interval
|
Displays the number of seconds between OSPF hello packet advertisements sent by OSPF routers. Ten seconds is the Cisco default.
|
Transit Delay
|
Displays the service speed. One second is the Cisco default.
|
LAN Metric
|
Displays a cost for sending packets across the LAN. This value should always be lower than the DCC metric. Ten is the Cisco default.
|
OSPF Authentication
|
Authentication Type
|
Displays Simple Password if the router where the ONS 15310 MA is connected uses authentication. Otherwise, it displays No Authentication.
|
Authentication Key
|
Displays the OSPF key (password) if authentication is enabled.
|
Confirm Authentication Key
|
Retype the authentication key to confirm it.
|
B.8.1.3.4 OSPF Area Range Subtab
The OSPF Area Range subtab allows you to view information about OSPF area ranges and create or delete area ranges.
Table B-86 Field Descriptions for the OSPF Area Range Subtab
Field
|
Description
|
Range Address
|
Displays the area IP address for the ONS 15310 MA NEs that reside within the OSPF area.
For example, if the ONS 15310 MA OSPF area includes nodes with IP addresses 10.10.20.100, 10.10.30.150, 10.10.40.200, and 10.10.50.250, the range address would be 10.10.0.0.
|
Range Area ID
|
Displays the OSPF area ID for the ONS 15310 MA. This is either the ID in the DCC OSPF area ID field or the ID in the area ID for LAN Port field.
|
Mask Length
|
Displays the subnet mask length.
|
Mask
|
Displays the subnet mask IP address.
|
Advertise
|
Indicates whether the OSPF range table is advertised.
|
B.8.1.3.5 OSPF Virtual Links Subtab
The OSPF Virtual Links subtab allows you to view information about OSPF virtual links and create or delete virtual links.
Note
You cannot create a new virtual link unless OSPF is active on the LAN.
Table B-87 Field Descriptions for the OSPF Virtual Links Subtab
Field
|
Description
|
Neighbor
|
Displays the router ID of the Area 0 router.
|
Transit Delay (sec)
|
Displays the service speed. One second is the Cisco default.
|
Retransmit Interval (sec)
|
Displays the time that will elapse before a packet is resent. Five seconds is the Cisco default.
|
Hello Interval (sec)
|
Displays the number of seconds between OSPF hello packet advertisements sent by OSPF routers. Ten seconds is the Cisco default.
|
Dead Interval (sec)
|
Displays the number of seconds that will pass while the packets of an OSPF router are not visible before its neighbors declare the router down. Forty seconds is the Cisco default.
|
Authentication Type
|
Displays the authentication type.
|
Authentication Key
|
Displays the authentication key.
|
B.8.1.3.6 SNMP Subtab
The SNMP subtab allows you to view SNMP information and create or delete SNMP trap destinations.
Table B-88 Field Descriptions for the SNMP Subtab
Field
|
Description
|
Allow SNMP Set
|
If checked, allows you to use SNMP management software with the ONS 15310 MA.
|
Allow SNMP Proxy
|
If checked, allows you to configure the ONS 15310 MA to proxy SNMP calls.
|
IP Address
|
The IP address of the NMS.
|
Community Name
|
The SNMP community name.
Note The SNMP community string cannot be blank in CTM. If a blank community string is required in CTC builds earlier than R4.6, you must set the blank community string in CTC.
|
UDP Port
|
The UDP port for SNMP. The Cisco default UDP port is 162.
|
Trap Version
|
The trap version, either SNMP version 1 or version 2. See your NMS documentation to determine whether to use SNMP version 1 or version 2.
|
Relay A IP Address
|
The first ONS 15310 MA to relay traps through. The IP address is appended to the base community string (to tell the first NE that is relaying the trap), the IP address, and port to forward the trap to. The second NE recognizes the IP address and strips it from the community string before forwarding the trap.
|
Relay A Community Name
|
The community name for the relay A node to use in the trap when forwarding it.
|
Relay B IP Address
|
The second ONS 15310 MA to relay traps through.
|
Relay B Community Name
|
The community name for the relay B node to use in the trap when forwarding it.
|
Relay C IP Address
|
The third ONS 15310 MA to relay traps through.
|
Relay C Community Name
|
The community name for the relay C node to use in the trap when forwarding it.
|
B.8.1.3.7 Firewall/Proxy Subtab
The Firewall/Proxy subtab allows you to use an NE as a proxy server or as a firewall.
Table B-89 Field Descriptions for the Firewall/Proxy Subtab
Field
|
Description
|
Gateway Settings
|
Enable Proxy Server on Port
|
If checked, the ONS 15310 MA serves as a proxy for connections between the CTM server and ONS 15310s that are DCC-connected to the proxy ONS 15310 MA. The CTM server establishes connections to DCC-connected nodes through the proxy node. The CTM server can connect to nodes that it cannot directly reach from the host on which it runs. The proxy server port number (read-only) is displayed following the Enable Proxy Server on Port field. The proxy server uses port number 1080.
If checked, the following radio buttons are enabled:
• External Network Element (ENE)—Enables the ONS 15310 MA to proxy as an ENE. Note that an alternate expansion for ENE is end network element.
• Gateway Network Element (GNE)—Enables the ONS 15310 MA to proxy as a GNE.
• Proxy-only—Enables proxy only.
If unchecked, the node does not proxy.
|
B.8.1.3.8 RIP Routing Table Subtab
The RIP Routing Table subtab allows you to view the Routing Information Protocol (RIP) routing table.
Table B-90 Field Descriptions for the RIP Routing Table Subtab
Field
|
Description
|
Destination
|
Displays the IP address of the destination network or host.
|
Mask
|
Displays the subnet mask used to reach the destination host or network.
|
Gateway
|
Displays the IP address of the gateway used to reach the destination network or host.
|
Cost
|
Displays the hop count metric. The valid range is from 1 to 15.
|
B.8.1.3.9 RIP Subtab
The RIP subtab allows you to view and configure RIP parameters.
Note
When you enable RIP, you must wait for approximately one minute for the default RIP address summary to become visible.
Note
When you disable RIP on the NE, all summary address entries in the Summary Address table will be deleted.
Table B-91 Field Descriptions for the RIP Subtab
Field
|
Description
|
RIP Active
|
Enable or disable RIP.
|
RIP Type
|
Select RIP version 1.0 or RIP version 2.0.
|
Metric
|
Select the hop count metric. The valid range is from 1 to 15.
|
Authentication
|
Authentication Type
|
Select the authentication type.
|
Authentication Key
|
Enter the authentication key (password) if the authentication type is Simple Password.
|
Confirm Authentication Key
|
Retype the authentication key to confirm it.
|
RIP Address Summary
|
• Summary Address—Displays the summary address.
• Mask Length—Displays the subnet mask length.
• Cost—Displays the hop count metric. The valid range is from 1 to 15.
|
B.8.1.3.10 Routing Table Subtab
The Routing Table subtab allows you to view the OSPF routing table.
Table B-92 Field Descriptions for the Routing Table Subtab
Field
|
Description
|
Destination
|
Displays the IP address of the destination network or host.
|
Mask
|
Displays the subnet mask used to reach the destination host or network.
|
Gateway
|
Displays the IP address of the gateway used to reach the destination network or host.
|
Usage
|
Shows the number of times the listed route has been used.
|
Interface
|
Shows the ONS 15310 MA interface used to access the destination. Values are:
• cpm0—The ONS 15310 MA Ethernet interface (that is, the RJ-45 jack on the TCC+/TCC2 and the LAN 1 pins on the backplane)
• pdcc0—An SDCC interface (that is, an OC-N trunk card identified as the SDCC termination)
• lo0—A loopback interface
|
B.8.1.3.11 Proxy Tunnels Subtab
The Proxy Tunnels subtab allows you to configure source and destination information for proxy tunnels.
Table B-93 Field Descriptions for the Proxy Tunnels Subtab
Field
|
Description
|
Source Address
|
Specify the source IP address in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Source Mask
|
Specify the source subnetwork mask in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Destination Address
|
Specify the destination IP address in the source-destination pair for the tunnel that will be routed through the proxy server.
|
Destination Mask
|
Specify the destination subnetwork mask in the source-destination pair for the tunnel that will be routed through the proxy server.
|
B.8.1.3.12 Firewall Tunnels Subtab
The Firewall Tunnels subtab allows you to configure source and destination information for firewall tunnels.
Table B-94 Field Descriptions for the Firewall Tunnels Subtab
Field
|
Description
|
Source Address
|
Specify the source IP address in the source-destination pair for the tunnel that will be routed through the firewall.
|
Source Mask
|
Specify the source subnetwork mask in the source-destination pair for the tunnel that will be routed through the firewall.
|
Destination Address
|
Specify the destination IP address in the source-destination pair for the tunnel that will be routed through the firewall.
|
Destination Mask
|
Specify the destination subnetwork mask in the source-destination pair for the tunnel that will be routed through the firewall.
|
B.8.1.4 DCC Tab
The DCC tab allows you to create, delete, and view SONET or SDH DCCs.
Table B-95 Field Descriptions for the DCC Tab
Field
|
Description
|
SDCC
|
SDCC Terminations
|
Displays the slot, port, and card type of an SDCC termination.
|
OSPF Disabled on Link
|
Check to prevent the advertisement of the OSPF routing table.
|
Foreign
|
A check mark indicates that the far-end node is a non-ONS node.
|
Foreign IP
|
Displays the foreign node IP address.
|
LAPD Config
|
If the SDCC is provisioned as OSI only, the following SDCC LAP-D parameters are displayed:
• AITS/UITS—Indicates the LAP-D acknowledgement type, either AITS (Acknowledged Information Transfer Service) or UITS (Unacknowledged Transfer Service).
• Network/User—Indicates the LAP-D frame command/response role, either Network or User.
• MTU—Shows the size of the maximum transfer unit (MTU). The range is from 512 to 1500 octets.
• T2000—Shows the time between SABME (Set Asynchronous Balanced Mode) frame transmission. The range is from 0.2 to 20 seconds.
• T203—Shows the maximum time between LAP-D frame exchanges. The range is from 4 to 120 seconds.
|
OSI SNPA
|
If the SDCC is provisioned for OSI, the following subnetwork point-of-attachment (SNPA) information is displayed:
• Router—Indicates the ONS router and NSAP address.
• Router State—Indicates whether the router is enabled or disabled.
|
LDCC
|
LDCC Terminations
|
Displays the slot, port, and card type of an LDCC termination. Click Create to create a new LDCC termination; click Delete to delete the selected LDCC termination.
|
OSPF Disabled on Link
|
Check to prevent the advertisement of the OSPF routing table.
|
Foreign
|
A check mark indicates that the far-end node is a non-ONS node.
|
Foreign IP
|
Displays the foreign node IP address.
|
LAPD Config
|
If the SDCC is provisioned as OSI only, the following SDCC LAP-D parameters are displayed:
• AITS/UITS—Indicates the LAP-D acknowledgement type, either AITS (Acknowledged Information Transfer Service) or UITS (Unacknowledged Transfer Service).
• Network/User—Indicates the LAP-D frame command/response role, either Network or User.
• MTU—Shows the size of the maximum transfer unit (MTU). The range is from 512 to 1500 octets.
• T2000—Shows the time between SABME (Set Asynchronous Balanced Mode) frame transmission. The range is from 0.2 to 20 seconds.
• T203—Shows the maximum time between LAP-D frame exchanges. The range is from 4 to 120 seconds.
|
OSI SNPA
|
If the SDCC is provisioned for OSI, the following subnetwork point-of-attachment (SNPA) information is displayed:
• Router—Indicates the ONS router and NSAP address.
• Router State—Indicates whether the router is enabled or disabled.
|
Create button
|
Allows you to create new terminations on SONET or SDH cards.
|
Edit button
|
Allows you to modify existing terminations on SONET or SDH cards.
|
Delete button
|
Allows you to delete the selected SDCC or LDCC.
|
B.8.1.5 Timing Tab
The Timing tab contains the following subtabs:
•
General Subtab
•
Reference List Subtab
•
Status Subtab
•
Timing Report Subtab
B.8.1.5.1 General Subtab
The General subtab displays general timing information.
Table B-96 Field Descriptions for the General Subtab
Field
|
Description
|
General Timing
|
Timing Mode
|
Set the node timing mode:
• External—The ONS 15310 MA derives its timing from a BITS source wired to the backplane pins.
• Line—Timing is derived from an OC-N card (non-DWDM nodes) or OSC card (DWDM nodes) that is optically connected to the timing node.
• Mixed—Timing is set to external and line timing references.
Caution  Mixed timing might cause timing loops; it is recommended that you use this mode with care.
|
SSM Message Set
|
Choose the sync status message (SSM) set level supported by your network. SSM is a SONET protocol that communicates information about the quality of the timing source. SSM messages are carried on the S1 byte of the SONET Line layer. They enable SONET devices to automatically select the highest quality timing reference and to avoid timing loops.
If a Generation 1 node receives a Generation 2 message, the message will be mapped down to the next available Generation 1. For example, an ST3E message becomes an ST3.
|
Revertive
|
If checked, the ONS 15310 MA reverts to a primary reference source after the conditions that caused it to switch to a secondary timing reference are corrected.
|
Reversion Time
|
Use the Reversion Time field to specify the time in half-minute increments.
|
Quality of RES
|
If your timing source supports the reserved S1 byte, you set the timing quality here. (Most timing sources do not use RES.) Qualities are displayed in descending quality order as ranges. For example, ST3 < RES < ST2 means the timing reference is higher than a Stratum 3 and lower than a Stratum 2.
|
BITS-IN-OUT Facility Type
|
In Facility Type
|
Provision the BITS In facility type.
|
Out Facility Type
|
Provisions the BITS Out facility type.
|
BITS Facilities 1
|
In State
|
Set the BITS In state to In Service (IS) or Out of Service (OOS). If Timing Mode is set to External or Mixed, set the BITS In State for BITS-1 and/or BITS-2 to IS (In Service) depending on whether one or both BITS input pin pairs on the backplane are connected to the external timing source. If Timing Mode is set to Line, set the BITS In State to OOS.
|
Coding
|
Set to the coding used by your BITS reference, either B8ZS or AMI.
|
Framing
|
Set to the framing used by your BITS reference, either Extended Super Frame (ESF), or Super Frame (SF). SSM is not available with Super Frame.
|
Sync Messaging
|
If checked, enables the Synchronization Status Message (SSM) for BITS In. (SSM is not available if Framing is set to Super Frame.)
|
Admin SSM
|
If the Sync Messaging check box is not checked, you can choose the SSM Generation 2 type from the drop-down list.
|
BITS OUT Facilities
|
Out State
|
Set the BITS reference to IS (In Service) or OOS (Out of Service). For nodes set to Line timing with no equipment timed through BITS Out, set State to OOS. For nodes using External timing or Line timing with equipment timed through BITS Out, set State to IS.
|
Coding
|
Set to the coding used by your BITS reference, either B8ZS or AMI.
|
Framing
|
Set to the framing used by your BITS reference, either ESF or SF (D4). SSM is not available with Super Frame.
|
AIS Thresh
|
If SSM is disabled or Super Frame is used, sets the quality level where a node sends an AIS from the BITS-1 Out and BITS-2 Out backplane pins. An AIS is raised when the optical source for the BITS reference falls to or below the SSM quality level defined in this field.
|
LBO
|
If you are timing an external device connected to the BITS Out pins, set the distance between it and the ONS 15327. Options are 0-133 ft. (Cisco default), 134-266 ft., 267-399 ft., 400-533 ft., and 534-655 ft.
|
B.8.1.5.2 Reference List Subtab
The Reference List subtab provides timing reference information.
Table B-97 Field Descriptions for the Reference List Subtab
Field
|
Description
|
NE References
|
Allows you to define three timing references (Ref-1, Ref-2, Ref-3). The node uses Reference 1 unless a failure occurs on that reference, in which case, the node uses Reference 2. If that fails, the node uses Reference 3, which is typically set to the internal clock. This is the Stratum 3 clock provided on the TCC+. The options displayed depend on the Timing Mode setting.
• Timing Mode set to External—Options are BITS-1, BITS-2, and Internal.
• Timing Mode set to Line—Options are the node's working optical cards and Internal.
Select the cards/ports that are directly or indirectly connected to the node wired to the BITS source; that is, the node's trunk cards. Set Reference 1 to the trunk card that is closest to the BITS source. For example, if Slot 5 is connected to the node wired to the BITS source, select Slot 5 as Reference 1.
• Timing Mode set to Mixed—Both BITS and optical cards are available, allowing you to set a mixture of external BITS and optical trunk cards as timing references.
|
BITS-1 Out References
|
Allows you to define three timing references (Ref-1, Ref-2, Ref-3) for equipment wired to the BITS Out backplane pins. Normally, BITS Out is used with line nodes, so the options displayed are the working optical cards. BITS-1 Out is enabled as soon as BITS-1 facilities are placed in service.
|
BITS-2 Out References
|
Allows you to define three timing references (Ref-1, Ref-2, Ref-3) for equipment wired to the BITS Out backplane pins. Normally, BITS Out is used with line nodes, so the options displayed are the working optical cards. BITS-1 and BITS-2 Out are enabled as soon as BITS-1 and BITS-2 facilities are placed in service.
|
B.8.1.5.3 Status Subtab
The Status subtab provides timing status information.
Note
If you change any values in the Status subtab and click Apply at the bottom of the screen, the values are not set. Instead, use the following buttons to apply changes:
•
Clear—Releases any existing switch request. For example, if you issue a Force Switch and then issue a Clear, the Force Switch request is released.
•
Manual Switch—Switches the timing reference from one source to another.
•
Force Switch—Switches the timing reference from one source to another. This request has a higher priority than the Manual Switch request.
Table B-98 Field Descriptions for the Status Subtab
Field
|
Description
|
NE Clock
|
NE Reference
|
Set the NE timing reference to internal, BITS-1, or BITS-2.
|
Status
|
Displays the status of the NE clock.
|
Operations
|
Execute a switch on the NE timing reference. Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
BITS-1 Out
|
BITS-1 Out
|
Set the BITS-1 out timing reference.
|
Status
|
Displays the status of the BITS-1 Out timing reference.
|
Operations
|
Execute a switch on the BITS-1 Out timing reference. Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
BITS-2 Out
|
BITS-2 Out
|
Set the BITS-2 out timing reference.
|
Status
|
Displays the status of the BITS-2 Out timing reference.
|
Operations
|
Executes a switch on the BITS-2 Out timing reference. Allows you to perform a manual switch, perform a forced switch, or clear the existing command switching.
|
B.8.1.5.4 Timing Report Subtab
The Timing Report subtab summarizes the NE's current timing settings.
B.8.1.6 Protection Tab
The Protection tab contains the following subtabs:
•
Protection Groups Subtab
•
Operations Subtab
B.8.1.6.1 Protection Groups Subtab
The Protection Groups subtab displays a list of available protection groups and allows you to create, delete, and view protection groups.
Table B-99 Field Descriptions for the Protection Groups Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups. Click the Create or Delete button to create a new protection group or delete an existing one.
|
Selected Protection Group
|
Name
|
Modify the name of the selected protection group. The name can have up to 32 alphanumeric characters.
|
Type
|
View the protection type (1:1 [card], 1:N [card], Y Cable [port], or 1+1 [port]) of the selected protection group.
|
Protect Module
|
View the protect module if using 1+1 protection.
|
Available Entities
|
Displays a list of available entities. You can toggle between available and working entities.
|
Working Entities
|
Displays a list of working entities. You can toggle between working and available entities.
|
Bidirectional Switching
|
Click if you want both the transmit and the receive channels to switch if a failure occurs on one. This option is only available if you select 1+1 (port) type.
|
Revertive
|
If checked, the node reverts traffic to the working card or port after failure conditions stay corrected for the amount of time entered in Reversion Time. This option is not available if the 1:N (card) type has been selected.
|
B.8.1.6.2 Operations Subtab
The Operations subtab displays the protection group operation information.
Table B-100 Field Descriptions for the Operations Subtab
Field
|
Description
|
Protection Groups
|
Displays a list of available protection groups.
|
Protection Group Details
|
Displays details about the selected protection groups and allows you to execute switch commands.
|
B.8.1.7 NE Defaults Tab
The NE Defaults tab displays a list of default thresholds for the ONS 15310 MA NE.
Table B-101 Field Descriptions for the NE Defaults Tab
Field
|
Description
|
Parameter
|
Lists the default NE parameter.
|
Value
|
Shows the default parameter value, and allows you to change the default.
|
Units
|
Lists the unit of measure that corresponds to the default NE parameter.
|
Range
|
Lists the possible range of values for the default NE parameter.
|
Side Effects
|
Lists any side effects that could occur as a result of changing the default NE parameter.
|
You can load different NE defaults using the NE Defaults Management window. See 4.5.12 Restoring NE Defaults, page 4-91.
B.8.1.8 Security Tab
The Security tab allows you to view and edit security features for the ONS 15310 MA NE. The Security tab contains the following subtabs:
•
Policy Subtab
•
Password Subtab
•
Access Subtab
•
RADIUS Server Subtab
•
Legal Disclaimer Subtab
B.8.1.8.1 Policy Subtab
The Policy subtab allows you to specify user security parameters.
Note
If the user is already logged in, any changes to the NE user type settings become applicable only when the user next logs in.
Table B-102 Field Descriptions for the Policy Subtab
Field
|
Description
|
Idle User Timeout
|
Each CTC or TL1 user can be idle during his or her login session for a specified amount of time before the CTC window is locked. The lockouts prevent unauthorized users from making changes. Higher-level users have shorter default idle periods and lower-level users have longer or unlimited default idle periods. The user idle period can be modified by a SuperUser.
Note A user already logged into the node is not affected by a change to the Idle User Timeout policy.
|
Retrieve
|
Set the idle user timeout for a CTC Retrieve user.
|
Maintenance
|
Set the idle user timeout for a CTC Maintenance user.
|
Provisioner
|
Set the idle user timeout for a CTC Provisioner user.
|
SuperUser
|
Set the idle user timeout for a CTC SuperUser user.
|
User Lockout
|
Manual Unlock by SuperUser
|
If checked, the CTC SuperUser user must manually unlock locked out CTC users. If unchecked, locked out CTC users are automatically unlocked after the lockout duration period elapses.
|
Lockout Duration
|
Set the lockout duration period for locked out CTC users. This field is only enabled if the Manual Unlock by SuperUser check box is unchecked.
|
Failed Logins Allowed
|
Set the number of failed logins before the CTC user is automatically locked out.
|
Other
|
Single Sessions per User
|
If checked, each CTC user can only launch one session at a time.
|
Disable Inactive User
|
If checked, inactive users are disabled automatically for the amount of time in the Inactive Duration field.
|
Inactive Duration
|
Specify the inactive duration in days. The range is from 1 to 90 days; the Cisco default is 45 days. A value of 0 implies inactive duration is disabled and invalid.
|
B.8.1.8.2 Password Subtab
The Password subtab allows you to specify user password security parameters.
Table B-103 Field Descriptions for the Password Subtab
Field
|
Description
|
Password Change
|
Prevent Reusing Last
|
Prevents setting a CTC user's current password to one of the most recent passwords. You can set the number of most recent passwords that cannot be reused. The range is from 1 to 10.
|
Disable Password Flipping
|
If checked, users are not allowed to change passwords for the number of days specified in the Can Change Password After field.
|
Can Change Password After
|
Enter the number of days that must elapse before the user can change the password.
|
Force Password Change After Assigned
|
If checked, during the first successful login, the user is forced to change the password.
|
Password Difference
|
Allows SuperUsers to specify the number of characters by which the new password of a user must differ from the old password, while performing a password change. The default value is 1. The range is from 1 to 5 characters.
|
Password Aging
|
Enable Password Aging
|
Check this check box to enable password aging.
|
Aging Period
|
Enter the aging period, in days, for Retrieve, Maintenance, Provisioner, and SuperUser CTC users. After the aging period expires, CTC users are forced to change their passwords.
|
Warning Period
|
Enter the warning period, in days, for Retrieve, Maintenance, Provisioner, and SuperUser CTC users. After the warning period expires, CTC users are warned that their passwords will soon expire.
|
B.8.1.8.3 Access Subtab
The Access subtab allows you to configure LAN and shell access to the NE.
Table B-104 Field Descriptions for the Access Subtab
Field
|
Description
|
LAN Access
|
LAN Access
|
Specify the type of LAN access allowed. Values allowed for the ONS 15310 MA are Front Only, Backplane Only, Front and Backplane Only, or No LAN Access.
Note After setting the LAN access to the backplane, the CTM client is unusable for 4 to 5 minutes.
|
Restore Timeout
|
This time period begins if No LAN Access is selected and all DCC connections are lost. If the time expires before a DCC is restored, LAN access is restored so that the node is not isolated. When the DCC comes back, LAN access returns to its specified settings. The range is from 0 (never) to 60 minutes; the Cisco default is 5 minutes.
|
Serial Craft Access (available for ONS 15310 MA NEs R7.0 and later)
|
Enable Craft Port A
|
Check this check box to enable craft port A.
|
Enable Craft Port B
|
Check this check box to enable craft port B.
|
Shell Access
|
Shell Access on
|
Specify shell access on Telnet or SSH.
|
SSH Port
|
Indicates the SSH port number that will be used if the SSH radio button is selected.
|
SFTP Port
|
Indicates the SFTP port number.
|
Telnet Port
|
This is enabled if you selected the Telnet radio button. Enter the Telnet port number.
|
Use Standard Telnet Port
|
If checked, the standard Telnet port is used for Telnet access.
|
Shell Access (available for ONS 15310 MA NEs R7.0 and later)
|
Access State
|
Select the Shell access state from the pull-down menu. You can select Disable, Non-secure, or Secure.
|
SSH Port
|
Indicates the SSH port number that will be used.
|
Telnet Port
|
This is enabled if you selected the Non-secure access state. Enter the Telnet port number that will be used.
|
Use Standard Telnet Port
|
Check this check box to indicate that the standard Telnet port will be used.
|
Enable Shell Password
|
Indicates whether or not the Shell password is enabled.
Note You cannot enable the Shell password in CTM R7.2. Enabling and providing a Shell password is currently done in CTC.
|
EMS Access (available for ONS 15310 MA NEs R7.0 and later)
|
Access State
|
Select the EMS access state from the pull-down menu. You can select either Non-secure or Secure.
|
CORBA Listener Port
|
Select the port numbers for the CTX CORBA (IIOP) listener port and the CTX CORBA (SSLIOP) listener port. Select one of the following radio buttons:
• Default-Fixed—Assigns a default port number.
• Standard Constant—Port number for the CTX CORBA (IIOP) listener port will be 683. Port number for the CTX CORBA (SSLIOP) listener port will be 684.
• Other Constant—When selected, enter the port number that will be used.
|
TL1 Access (available for ONS 15310 MA NEs R7.0 and later)
|
Access State
|
Select the TL1 access state from the pull-down menu. You can select Disable, Non-secure, or Secure.
|
SNMP Access (available for ONS 15310 MA NEs R7.0 and later)
|
Access State
|
Select the SNMP access state from the pull-down menu. You can select either Disable or Non-secure.
|
Other
|
PM Clearing Privilege
|
Select the users privilege that allows clearing PM statistics for the NE.
|
B.8.1.8.4 RADIUS Server Subtab
The RADIUS Server subtab allows you to configure, create, modify, and delete RADIUS servers for the ONS 15310 MA R7.0 and later.
Table B-105 Field Descriptions for the RADIUS Server Subtab
Field
|
Description
|
Enable RADIUS Authentication
|
Check this check box to enable RADIUS authentication.
|
Enable RADIUS Accounting
|
Check this check box to enable RADIUS accounting. This is enabled if the Enable RADIUS Authentication check box is checked.
|
Enable the Node as the Final Authenticator When no RADIUS server is reachable
|
Select a row from the RADIUS Servers in Order of Authentication table; then, check this check box. This indicates that the RADIUS server that you selected will be the final authenticator when there are no more RADIUS servers that can be reached.
|
Create
|
Click this button to create a RADIUS server. See 8.4.2.1.1 Creating a RADIUS Server, page 8-51.
|
Edit
|
Click this button to modify an existing RADIUS server's information. See 8.4.2.1.2 Modifying a RADIUS Server, page 8-52.
|
Delete
|
Click this button to delete an existing RADIUS server. See 8.4.2.1.3 Deleting a RADIUS Server, page 8-52.
|
Move Up/Move Down
|
Select the Move Up and Move Down buttons to reorder the list of RADIUS servers in the RADIUS Servers in Order of Authentication table.
|
RADIUS Servers in Order of Authentication
|
IP Address
|
Displays the IP address of the RADIUS server.
|
Shared Secret
|
Displays a text string that serves as a password between a RADIUS client and RADIUS server.
|
Authentication Port
|
Displays the authentication port number of the RADIUS server. Default access is through port number 1812.
|
Accounting Port
|
Displays the accounting port number of the RADIUS server. Default access is through port number 1813.
|
B.8.1.8.5 Legal Disclaimer Subtab
The Legal Disclaimer subtab allows you to edit the NE's advisory message and preview the disclaimer.
Table B-106 Field Descriptions for the Legal Disclaimer Subtab
Subtab
|
Description
|
Advisory Message
|
The existing message is a default, noncustomer-specific disclaimer. If you want to edit this statement with specifics for your company, you can change the text. You can also use the following HTML commands to format the text:
<b> Begins boldface font
</b> Ends boldface font
<center> Aligns type in the center of the window
</center> Ends the center alignment
<font=n, where n = point size> Changes the font to the new size
</font> Ends the font size command
<p> Creates a line break
<sub> Begins subscript
</sub> Ends subscript
<sup> Begins superscript
</sup> Ends superscript
<u> Starts underline
</u> Ends underline
|
Preview
|
Allows you to view the advisory message before saving it.
|
B.8.1.9 Alarm Tab
The Alarm tab allows you to change default alarm severities by creating unique alarm profiles for individual ONS 15310 MA nodes. The Alarm tab contains the following subtabs:
•
Profile Subtab
•
Alarm Behavior Subtab
Note
The Alarm tab might contain default alarm profile entries for cards that are not supported by the Cisco ONS 15310. Therefore, you might see some alarms that do not apply to the NE type that you are provisioning.
B.8.1.9.1 Profile Subtab
The Profile subtab allows you to select, create, or delete alarm profiles.
Table B-107 Field Descriptions for the Profile Subtab
Field
|
Description
|
Alarm Profile Name
|
Choose an alarm profile for the NE from the drop-down list. Click Create to create a new alarm profile for the NE. Click Delete to delete an alarm profile from the NE.
|
Condition
|
Displays the alarm condition.
|
Severity
|
Displays the alarm severity.
|
B.8.1.9.2 Alarm Behavior Subtab
The Alarm Behavior subtab allows you to change default alarm severities by creating unique alarm profiles.
Table B-108 Field Descriptions for the Alarm Behavior Subtab
Field
|
Description
|
Alarm Profile
|
Choose a global alarm profile for the NE from the drop-down list.
|
Suppress Alarms
|
If checked, all alarms are suppressed.
|
Slot Number
|
Displays the location of the module.
|
Equipment Type
|
Displays the type of module in the slot.
|
Profile
|
Choose an alarm profile for the slot from the drop-down list.
|
Suppress Alarms
|
Indicates whether or not the alarms for the particular card are suppressed. If checked, all alarms are suppressed for the port.
|
B.8.1.10 XC Utilization Tab
The XC Utilization tab allows you to view a summary of the percentage of XTC cross-connect resources used by circuits that traverse or terminate at an ONS 15310 MA.
Table B-109 Field Descriptions for the XC Utilization Tab
Field
|
Description
|
STS-1 Matrix
|
Provides the percentage of the XC cross-connect STS-1 paths resources that are used.
|
VT Matrix Ports
|
Provides the percentage of the XTC cross-connect VT matrix ports that are used. Each port is one STS in size, and each can transport 28 VT1.5s. 24 VT matrix ports are available.
|
VT Matrix
|
Provides the percentage of the VT matrix resources that are used. 672 are available, which is the number of VT matrix ports (24) multiplied by the number of VT1.5s in an STS (28).
|
B.8.1.11 OSI Tab
Note
The OSI tab is supported only for the ONS 15310 MA R7.0 and later.
The OSI tab allows you to provision ONS 15310 MA Open System Interconnection (OSI) parameters. It contains the following subtabs:
•
Main Setup Subtab
•
TARP-Config Subtab
•
TARP-TDC Subtab
•
TARP-MAT Subtab
•
Routers-Setup Subtab
•
Subnets Subtab
•
Tunnels Subtab
•
IS-IS RIB Subtab
•
ES-IS RIB Subtab
B.8.1.11.1 Main Setup Subtab
The Main Setup subtab allows you to provision the OSI Network Entity Title (NET) address and the OSI routing mode.
Table B-110 Field Descriptions for the Main Setup Subtab
Field
|
Description
|
Main Network Entity Title
|
Displays the node NET. The NET is used in OSI networks to identify the node to the end system (ES) or intermediate system (IS).
|
End System
|
Provisions the node as an OSI End System (ES). ESs send End System Hello (ESH) messages regularly to announce their presence to neighboring ISs and ESs. For the ONS 15310 MA, End System is the Cisco default.
|
Intermediate System Level 1
|
Provisions the node as an OSI Intermediate System (IS). ISs send Intermediate System Hello (ISH) messages regularly to announce their presence to neighboring ISs and ESs.
|
Intermediate System Level 1/Level 2
|
The ONS 15310 MA performs all IS functions. It communicates with other IS and ES nodes within an OSI area and broadcasts ISHs to IS nodes in other areas to which it is connected.
|
Node Routing Mode
|
L1 LSP Buffer Size
|
Sets the Level 1 Link State Protocol (LSP) data unit buffer size. The Cisco default 512.
|
L2 LSP Buffer Size
|
Sets the Level 2 Link State Protocol (LSP) data unit buffer size. The Cisco default 512.
|
B.8.1.11.2 TARP-Config Subtab
The TARP Config subtab allows you to provision the TID Address Resolution protocol (TARP). TARP is used when TL1 TIDs must be translated to an NSAP address. During the TID-to-NSAP translation, the TID is mapped to a NET; then, the NSAP is derived from the NET based on the NSAP selector value.
Table B-111 Field Descriptions for the TARP-Config Subtab
Field
|
Description
|
TARP PDUs L1 Propagation
|
If checked (default), TARP Type 1 PDUs received by the node that are not excluded by the loop detection buffer are propagated to other NEs within the OSI Level 1 area. Type 1 PDUs request a protocol address that matches a target TID within a Level1 routing area. The propagation does not occur if the NE is the target of the Type 1 PDU and the PDUs are not propagated to the NE from which the PDU was received.
Note This parameter is not used when the node is set to End System.
|
TARP PDUs Origination
|
If checked (default), the node performs all TARP configuration functions, including:
• TID-to-NSAP resolution requests
• NSAP-to-TID requests
• TARP address changes
Note TARP Echo and NSAP to TID are not supported.
|
L2 TARP Data Cache
|
If checked (default), the TIDs and NSAPs are added to the TDC before the node propagates the requests to other NEs.
Note This parameter is designed for IS Level 1/Level 2 nodes that are connected to other IS Level 1/Level 2 nodes. Enabling the parameter for IS Level 1 nodes is not recommended.
|
LAN TARP Storm Suppression
|
If checked (default), enables the TARP storm suppression to prevent redundant TARP PDUs from being propagated across the network.
|
Type 4 PDU Delay
|
Sets the amount of time that will pass before the Type 4 PDU is generated. The Cisco default value is 60 seconds. The range is from 0 to 255 seconds.
|
TARP PDUs L2 Propagation
|
If checked (default), TARP Type 2 PDUs received by the node that are not excluded by the loop detection buffer are propagated to other NEs within the OSI Level 2 area. Type 2 PDUs request a protocol address that matches a target TID within a Level 2 routing area. The propagation occurs if the NE is the not the target of the Type 2 PDU and the PDUs are not propagated to the NE from which the PDU was received.
|
L1 TARP Data Cache
|
If checked, the node maintains a TARP data cache (TDC). The TDC is a database of TID to NSAP pairs created from TARP Type 3 PDUs received by the node. TARP 3 PDUs are responses to Type 1 and Type 2 PDUs and modified by TARP Type 4 PDUs (TID to NSAP updates or corrections).
|
LDB
|
If checked, enables the TARP loop detection buffer (LDB). The LDB prevents TARP PDUs from being sent more than once on the same subnet.
|
Send Type 4 PDU on Startup
|
If checked, a TARP Type 4 PDU is originated during the initial ONS 15310 MA startup. Type 4 PDUs indicate a TID or NSAP change has occurred at the NE. This is disabled by default.
|
Timers
|
LDB Entry
|
Sets the TARP LDB timer. The LDB buffer time is assigned to each LDB entry for which the TARP sequence number is zero. The Cisco default is 5 minutes. The range is from 1 to 10 minutes.
|
T1 Timer
|
Sets the amount of time to wait for response to a Type 1 Request PDU. Type 1 requests seek a specific NE TID within an OSI Level 1 area. The Cisco default is 15 seconds. The range is from 0 to 3600 seconds.
|
T3 Timer
|
Sets the amount of time to wait for an address resolution request. The Cisco default is 40 seconds. The range is from 0 to 3600 seconds.
|
LDB Flush
|
Sets the frequency period for flushing the LDB. The Cisco default is 5 minutes. The range is from 0 to 1440 minutes.
|
T2 Timer
|
Sets the amount of time to wait for a Type 2 Request PDU. TARP Type 2 requests seek a specific NE TID within an OSI Level 1 area. The Cisco default is 25 seconds. The range is from 0 to 3600 seconds.
|
T4 Timer
|
Sets the amount of time to wait for an error recovery. The timer begins after the T2 timer expires without successfully finding the NE TID. The Cisco default is 20 seconds. The range is from 0 to 3600 seconds.
|
B.8.1.11.3 TARP-TDC Subtab
Table B-112 Field Descriptions for the TARP-TDC Subtab
Field
|
Description
|
Add Static Entry button
|
Click this button to statically link a TID to an NSAP or NET.
|
Delete Selected Entry button
|
Deletes the selected TID to NSAP/NET static entry.
|
TID to NSAP button
|
Click this button to query the network for an NSAP that matches a TID.
|
Flush Dynamic Entries button
|
Click this button to delete all dynamically generated TDC entries.
|
TID
|
Target ID that is statistically linked to an NSAP or NET. For ONS nodes, the TID is the node name.
|
NSAP/NET
|
The NSAP that is statistically linked to the TID.
|
Type
|
Indicates how the TARP data cache entry was created. It can be either:
• Dynamic—The entry was created through the TARP propagation process.
• Static—The entry was manually created and is a static entry.
|
B.8.1.11.4 TARP-MAT Subtab
The TARP-MAT subtab allows you to manually provision a TARP adjacency.
Table B-113 Field Descriptions fo