Cisco Transport Manager GateWay/CORBA User's Guide and Programmer Manual, 7.2
Appendix A: Notifications, Fault Management, and Probable Cause Mapping

Table Of Contents

Notifications, Fault Management, and Probable Cause Mapping

A.1  Overview of Notifications

A.2  Resolving the Notification Service

A.3  Tips to Improve Notification Throughput

A.4  Supported Events

A.4.1  Object Creation

A.4.2  Object Deletion

A.4.3  Attribute Value Change

A.4.4  State Change Event

A.4.5  Protection Switch

A.4.6  Threshold Crossing Alert

A.4.7  Alarm

A.4.8  Heartbeat Event

A.5  Probable Cause Mapping

A.5.1  TMF-Defined Probable Cause

A.5.2  CTM GateWay/CORBA Mapping—EMS

A.5.3  CTM GateWay/CORBA Mapping—CRS-1 and XR 12000

A.5.4  CTM GateWay/CORBA Mapping—MGX 8880/8850/8830

A.5.5  CTM GateWay/CORBA Mapping—ONS 15216

A.5.6  CTM GateWay/CORBA Mapping—ONS 15302, ONS15305, and ONS15305 CTC

A.5.7  CTM GateWay/CORBA Mapping—ONS15327, ONS 15454 SONET, and ONS 15454 SDH, R4.0 and R4.1

A.5.8  CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS15327, ONS 15454 SONET, and ONS 15454 SDH R5.0

A.5.9  CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS 15327, ONS 15454 SONET, and ONS 15454 SDH R6.0 and R7.2

A.5.10  CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS 15454 SONET, and ONS 15454 SDH R6.1

A.5.11  CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS 15454 SONET, and ONS 15454 SDH R6.2

A.5.12  CTM GateWay/CORBA Mapping—ONS 15501

A.5.13  CTM GateWay/CORBA Mapping—ONS 15530

A.5.14  CTM GateWay/CORBA Mapping—ONS 15540

A.5.15  Optical Monitoring Alarms—ONS 15530 and ONS 15540

A.5.16  CTM GateWay/CORBA Mapping—ONS 15600

A.5.17  CTM GateWay/CORBA Mapping—ONS 15600 SDH

A.5.18  CTM GateWay/CORBA Mapping—ONS 1580x


Notifications, Fault Management, and Probable Cause Mapping


This appendix includes information on CTM GateWay/CORBA's notifications, fault management, and probable cause mapping. It provides the following:

Overview of Notifications

Resolving the Notification Service

Tips to Improve Notification Throughput

Supported Events

Probable Cause Mapping

A.1  Overview of Notifications

The notification service forwards all fault notifications received from managed NEs to the network management system (NMS). The notification service also forwards object creation, object deletion, attribute change, protection switch, and threshold crossing alert (TCA) events. TMF 814 defines the structure and format of attributes for all events and alarms.

The CTM server and the Operations Support System (OSS) host must have Domain Name System (DNS) enabled in order to receive notifications. OSS clients running behind a firewall must configure an IIOP listening port to enable the TCP connection with the notification server. CTM must configure the notification service listening port number to allow OSS clients to communicate with the notification service.

CTM creates the notification channel with the following QoS parameters:

Table A-1 QoS Parameters for the Notification Channel 

Parameter
Value

ConnectionReliability

BestEffort

StartTimeSupported

false

OrderPolicy

FifoOrder

DiscardPolicy

FifoOrder

MaxEventsPerConsumer1

10000

1 The MaxEventsPerConsumer value is configurable. To modify this value, see B.10  Configuring CTM GateWay/CORBA, page B-7. All other parameter values are defined by the TMF and cannot be changed.


The value of MaxEventsPerConsumer is configurable. To modify this value, see B.6  Using Multiple Naming Servers, page B-4. All other parameter values are defined by TMF and cannot be changed.

CTM sets RejectNewEvents administration property of the channel to true. This is defined by TMF.

Every notification that CTM generates has the QoS parameters listed in Table A-2. These parameter values are defined by the TMF and cannot be changed.

Table A-2 QoS Parameters for Notifications

Parameter
Value

EventReliability

BestEffort

Priority

DefaultPriority

Timeout

30 minutes for alarms and TCAs; 24 hours for all other notifications


The NMS retrieves all active alarms on the Element Management System (EMS) and on managed element objects. The NMS filters alarms based on probable cause and managed element name. CTM GateWay/CORBA forwards CTM-specific alarms to the NMS.

For NE-related alarms, CTM inserts the original probable cause in the alarm's nativeProbableCause field. The TMF-mapped probable cause is available in the probableCause field.

A.2  Resolving the Notification Service

CTM GateWay/CORBA can integrate with external notification services. When CTM GateWay/CORBA starts, a reference to EventNotifyChannelFactory is resolved. CTM GateWay/CORBA makes the following attempts to resolve the object:

1. Resolve initial references with the default service name of NotificationService to resolve the object. You can change the service name by setting the corbagw.notification.ServiceName property in the corbagw.properties file.

2. Resolve the object through the naming service. The default naming service entry is services. NotifyChannelFactory. You can change the naming service entry by setting the corbagw.notification.NamingContext property in the corbagw.properties file.

3. Resolve the object directly through the Interoperable Object Reference (IOR). You can change the URL of the IOR file by setting the corbagw.notification.FactoryIORFile property in the corbagw.properties file. The default location for the IOR file is file://localhost/CTM_baseDir/cfg/NotificationService.ior. You can specify a URL that points to a remote web server.

A.3  Tips to Improve Notification Throughput

While CTM GateWay/CORBA NBI and the bundled notification server are developed and tuned to provide high throughput, you might want to take additional steps to improve throughput and avoid any loss of notifications. You should implement the StructuredPushConsumer interface defined by the Object Management Group (OMG) and implement the push_structured_event method. The notification server invokes this method on the NMS.


Caution Because all CORBA calls are blocking, the notification server thread will block until the push_structured_event method completes. If you try to perform a time-consuming task before the method completes, you will block the notification server.

To improve throughput, you should receive the event and forward it to another thread for processing.

For example:

void push_structured_event(StructuredEvent notification) {
	try {
		some_other_thread_queue.addNotification(notification);
	} catch (Exception ex) {
		// catch all exception and ignore
		ex.printStackTrace();
	}
}


Caution As shown in the example, you must catch all the exceptions. If you do not catch all exceptions, you will stop receiving notifications.

A.4  Supported Events

A.4.1  Object Creation

The following subsections list the attributes of each event.

Table A-3 lists the Object Creation types and attributes.

Table A-3 Object Creation 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

No.

edgePoint

boolean

No.


Object creation notifications are sent to the NMS for the objects in Table A-4.

Table A-4 Object Creation Notifications 

Object Type
Type Sent in remainder_of_body for Object Creation Event

OT_MANAGED_ELEMENT

managedElement::ManagedElement_T

OT_MULTILAYER_SUBNETWORK

multiLayerSubnetwork::MultiLayerSubnetwork_T

OT_TOPOLOGICAL_LINK

topologicalLink::TopologicalLink_T

OT_SUBNETWORK_CONNECTION

subnetworkConnection::SubnetworkConnection_T

OT_EQUIPMENT

equipment::Equipment_T

OT_PROTECTION_GROUP

protection::ProtectionGroup_T

OT_L2TOPOLOGY

MultiLayerSubnetwork::L2Topology_T

OT_MLVLAN

MultiLayerSubnetwork::MLVLAN_T

OT_ROLL

MultiLayerSubnetwork::Roll_T

OT_VCAT

SubnetworkConnection::VCAT_T


CTM does not generate Object Creation events for SubnetworkConnection for ONS 15540.

CTM cannot give the object name for Object Creation events for ONS 15540, ONS 15530, and ONS 15501 equipment.

For MGX 8880/8850/8830, CTM generates Object Creation events for object types OT_MANAGED_ELEMENT and OT_EQUIPMENT.


Note The number of equipment holders for NEs supported by CTM is constant. To reduce traffic between CTM and the NMS, CTM does not generate Object Creation events for equipment holders. The number of PTPs on EQUIPMENT is also constant. Therefore, CTM generates only OBJECT_CREATION events for EQUIPMENT.


A.4.2  Object Deletion

Table A-5 lists the Object Deletion types and attributes.

Table A-5 Object Deletion 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

No.

edgePoint

boolean

No.


Object deletion notifications are sent to the NMS for the objects in Table A-6.

Table A-6 Object Deletion Notifications 

Object Type
Type Sent in remainder_of_body for Object Deletion Event

OT_MANAGED_ELEMENT

managedElement::ManagedElement_T

OT_MULTILAYER_SUBNETWORK

multiLayerSubnetwork::MultiLayerSubnetwork_T

OT_TOPOLOGICAL_LINK

topologicalLink::TopologicalLink_T

OT_SUBNETWORK_CONNECTION

subnetworkConnection::SubnetworkConnection_T

OT_EQUIPMENT

equipment::Equipment_T

OT_PROTECTION_GROUP

protection::ProtectionGroup_T

OT_L2TOPOLOGY

MultiLayerSubnetwork::L2Topology_T

OT_MLVLAN

MultiLayerSubnetwork::MLVLAN_T

OT_ROLL

MultiLayerSubnetwork::Roll_T

OT_VCAT

SubnetworkConnection::VCAT_T


CTM does not generate Object Deletion events for SubnetworkConnection for ONS 15540, ONS 15530, and ONS 15501.

For MGX 8880/8850/8830, CTM generates Object Deletion events for object types OT_MANAGED_ELEMENT and OT_EQUIPMENT.


Note The number of equipment holders for all NEs supported by CTM is constant. To reduce traffic between CTM and the NMS, CTM does not generate object deletion events for equipment holders. The number of PTPs on EQUIPMENT is also constant. Therefore, CTM generates only OBJECT_DELETION events for EQUIPMENT.


A.4.3  Attribute Value Change

Table A-7 lists the attribute value change (AVC) types and attributes

Table A-7 Attribute Value Change 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

No.

edgePoint

boolean

No.

attributeList

notifications::NVList_T

Yes.


Attribute value change notifications are sent to the NMS for the objects and attributes in Table A-8.

Table A-8 Attribute Value Change Notifications 

Object Type
Attributes

OT_EMS

nativeEMSName

OT_MANAGED_ELEMENT

nativeEMSName

location

version

productName

OT_MULTILAYER_SUBNETWORK

NativeEMSName

OT_TOPOLOGICAL_LINK1

None

OT_SUBNETWORK_CONNECTION2

None

OT_L2TOPOLOGY

NativeEMSName

OT_MLVLAN

None

Note The purpose of this event is to notify NMS that this VLAN has been updated.

OT_ROLL

None

Note The purpose of this event is to notify NMS that this Roll has been updated.

OT_VCAT

None

Note The purpose of this event is to notify NMS that this VCAT has undergone a change.

1 The OT_TOPOLOGICAL_LINK - event notifies the NMS that some attribute of topological link has changed.

2 The OT_SUBNETWORK_CONNECTION - event is generated only when CTM fails to delete SNC and it remains in same state.



Note CTM does not generate Attribute Change events for SubnetworkConnection for ONS 15540, ONS 15530, and ONS 15501 NEs.



Note For MGX 8880/8850/8830, CTM generates Attribute Change events for object types OT_MANAGED_ELEMENT and OT_EMS.


A.4.4  State Change Event

Table A-9 lists the state change event types and attributes.

Table A-9 State Change Event 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

No.

edgePoint

boolean

No.

attributeList

notifications::NVList_T

Yes.


Attribute change notifications are sent to the NMS for the objects and attributes in Table A-10.

Table A-10 State Change Event Notifications 

Object Type
Attributes

OT_MANAGED_ELEMENT

communicationState—CTM supports following values:

CS_AVAILABLE

CS_UNAVAILABLE

emsInSyncState—CTM will support following values:

True

False

OT_EQUIPMENT_HOLDER

holderState—State change. CTM supports the following values:

EMPTY

INSTALLED_AND_EXPECTED

EXPECTED_AND_NOT_INSTALLED

MISMATCH_OF_INSTALLED_AND_EXPECTED

OT_SUBNETWORK_CONNECTION1

sncState—CTM supports the following values:

SNCS_DELETING

SNCS_PARTIAL

SNCS_ACTIVE

OT_L2TOPOLOGY

L2TopoState—CTM supports the following values:

L2TS_COMPLETE

L2TS_INCOMPLETE

topoInSyncState—CTM supports following values:

true

false

OT_MLVLAN

vlanState—CTM supports following values:

VLS_COMPLETE

VLS_INCOMPLETE

OT_ROLL

rollState—CTM supports the following values:

ROLL_PENDING

ROLL_COMPLETED

ROLL_CANCELLED

ROLL_INCOMPLETE

OT_VCAT

vcatState—CTM supports the following values:

VCATS_DELETING

VCATS_PARTIAL

VCAT_ACTIVE

1 The OT_SUBNETWORK_CONNECTION event is generated only when CTM changes the SNC. If CTC or any other tool is used to change the SNC, CTM does not report this event.


CTM does not generate State Change events for EquipmentHolder and SubnetworkConnection for ONS 15540, ONS 15530, and ONS 15501 NEs.

For MGX 8880/8850/8830, CTM generates State Change events for object types OT_MANAGED_ELEMENT and OT_EQUIPMENT_HOLDER.

A.4.5  Protection Switch

Table A-11 lists the protection switch types and attributes.

Table A-11 Protection Switch 

Attribute Name
Type
Supported by CTM?

notificationId

String

Yes

The uniqueness and the sequence of the notificationId are not guaranteed

emsTime

globaldefs::Time_T

Yes

neTime

globaldefs::Time_T

No

ProtectionType

protection::ProtectionType_T

No

switchReason

protection::switchReason_T

No

layerRate

transmissionParameters::LayerRate_T

No

groupName

globaldefs::NamingAttributes_T

No

(yes for ONS 15540 and ONS 15530)

protectedTP

globaldefs::NamingAttributes_T

No

(yes for ONS 15540 and ONS 15530)

switchAwayFromTP

globaldefs::NamingAttributes_T

(yes for ONS 15540 and ONS 15530)

switchToTP

globaldefs::NamingAttributes_T

No

(yes for ONS 15540 and ONS 15530)

affectedTP

Note This is not defined by TMF.

globaldefs::NamingAttributes_T

Yes

(no for ONS 15540 and ONS 15530)

Description

Note This is not defined by TMF.

String

Yes

Value of this field is native NE event value.



Note This event is not supported for MGX 8880/8850/8830 NEs.


A.4.6  Threshold Crossing Alert

Table A-12 lists the protection switch types and attributes.

Table A-12 Protection Switch 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes.

The uniqueness and the sequence of the notificationId are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

nativeEMSName

string

Yes.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

Yes.

isClearable

boolean

Yes.

Always set to false.

perceivedSeverity

notifications::PerceivedSeverity_T

Yes.

Always set to PerceivedSeverity_T.PS_INDETERMINATE.

layerRate

transmissionParameters::LayerRate_T

Yes.

granularity

Granularity_T

Yes.

pmParameterName

PMParameterName_T

Yes.

Note If the NE does not report location, this field is empty.

pmLocation

PMLocation_T

Yes.

Note If the NE does not report location, this field is empty.

thresholdType

PMThresholdType_T

No.

value

float

Yes.

unit

string

No.



Note This event is not supported for ONS 15540, ONS 15530, ONS 15501, and MGX 8880/8850/8830 NEs because TCAs are reported as alarms.


A.4.7  Alarm

Table A-13 lists the most common alarm messages.

Table A-13 Alarm 

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.

objectName

globaldefs::NamingAttributes_T

Yes.

nativeEMSName

string

Yes.

nativeProbableCause

string

Yes.

Note In case of external condition alarms, the string value of the condition type will be appended to this field.

objectType

notifications::ObjectType_T

Yes.

emsTime

globaldefs::Time_T

Yes.

neTime

globaldefs::Time_T

Yes.

isClearable

boolean

Yes. The value is always set to True.

layerRate

transmissionParameters::LayerRate_T

Yes.

Note Not supported for ONS 15540, ONS 15530, and ONS 15501 NEs.

probableCause

string

Yes.

probableCauseQualifier

string

Yes. CTM provides the same value as in the nativeProbableCause field.

perceivedSeverity

notifications::PerceivedSeverity_T

Yes.

serviceAffecting

notifications::ServiceAffecting_T

Yes.

affectedTPList

globaldefs::NamingAttributesList_T

Yes.

additionalText

string

Yes.

additionalInfo

globaldefs::NVSList_T

Yes.

CTM provides subnetwork name when available.

If the alarmed object is OCn PTP, then CTM also includes SDH_SONET_SS_BITS in this list.

CTM provides IPAddress for ME-related alarms.

CTM provides ManagedElement Name when the object type is OT_EMS and the alarm is ME-related.

CTM provides "affectedObject", when the object type is OT_EMS and the nativeProbableCause is "Server Monitor Threshold Crossed".

isPropagated

boolean

Yes. For the MGX 8880/8850/8830, values will be assigned to this field. For all other NEs, this field will always be set to False.

aresFDN

string

Yes.



Note If there is an alarm on an STS/VC4 CTP utilizing all the ports of a DS1/E1 card, thealarm is reported with the containing PTP as port=127. If an STS/VC4 SNC exists with one of the drop CTPs of the SNC using all the ports on a DS1/E1 card, and if there is an alarm on the STS CTP, then CTM will report the port number of the containing PTP as 127.

ONS 15800, ONS 15801, and ONS 15808 alarms that are retrieved using the CTM GateWay/CORBA have OT_EQUIPMENT as the object_type field.


A.4.8  Heartbeat Event

CTM generates a periodic heartbeat event and pushes the event to the notification channel. By default, this function is disabled. You can configure the interval value through CTM Control Panel. If the interval value is set to 0, the heartbeat event is disabled. By monitoring this event, the NBI client knows whether the notification service is active. The type_name field contains the NT_HEART_BEAT value under the fixed_header for this type of event. Filterable_data has only one field, which is shown in Table A-14.

Table A-14 Heartbeat Event

Attribute Name
Type
Supported by CTM?

notificationId

string

Yes. The uniqueness and sequence of the notificationID are not guaranteed.


A.5  Probable Cause Mapping

A.5.1  TMF-Defined Probable Cause

The following report lists the probable causes defined by the TMF:

"UNIDENTIFIED": for alarms that do not match any other string below. EMS shall in this 
case fill out the additional text field as much as possible.
"AIS": alarm indication signal
"AMS": Alternate modulation signal
"AU-AIS": AU alarm indication signal
"BER_SD": signal degrade (includes receiver degrade)
"BER_SF": signal fail (includes receiver failure and excessive BER)
"DCC_FAILURE" : Data Communication Channel Failure
"EMS": EMS system alarm
"EMS_ALM_LOSS": The 1st notification that the EMS may supply after 1 or more notifications 
for protection switch, TCA, alarm, or file transfer status have been discarded by the EMS 
while other events have not been discarded
"EMS_LIFECYCLE_LOSS": The 1st notification that an EMS may supply after 1 or more events 
of type OC/OD/AVC/SC/RC have been discarded by the EMS
"EMS_ALM_AND_LIFECYCLE_LOSS": The 1st notification that an EMS may supply after 1 or more 
notifications for protection switch, TCA, alarm, or file transfer status, and 1 or more 
events of type OC/OD/AVC/SC/RC have been discarded by the EMS
"EQPT": equipment alarm 
"ENV" Environmental/external cause
"FOP_APS": failure of APS protocol
"LCD": Loss of Cell Delineation (from TC Adaptor part of ATM NI)
"LOF": loss of frame (when distinguished from LOS)
"LOM": loss of multiframe (SDH only, since not an alarm in GR-253)
"LOP": loss of pointer
"LOS": loss of signal
"MS-AIS": MS alarm indication signal
"OSC-AIS" : Optical Supervisory Channel alarm indication signal
"OSC_BER_SF" :Optical Supervisory Channel signal fail/RX fail/excessive BER
"OSC_FERF" : Optical Supervisory Channel Far End Receive Failure
"OSC_LOF" : Optical Supervisory Channel Loss of Frame
"OSC_LOS" : Optical Supervisory Channel Loss of Signal
"OSC_SD" : Optical Supervisiory Channel signal degrade
"PLM": payload label mismatch (when reported as an alarm)
"RAI": remote alarm indication (sometimes reported as RDI)
"SECURITY_VIOLATION": security violation
"SSF": server signal fail 
"TCM-AIS": Tandem Connection Sink - Incoming Alarm Indication Signal
"TCM-LOS": Tandem Connection Sink - Loss of Tandem Connection Signal
"TCM-OAI": Tandem Connection Sink - Outgoing Defect Indication ( same / similar to Alarm 
Indication)
"TCM-RAI": Tandem Connection Sink - Remote Defect Indication ( same / similar to Alarm 
Indication)
"TCM-SD" Tandem Connection Sink - Signal Degrade
"TCM-SSF": Tandem Connection Sink - Server Signal Fail
"TCM-TIM" Connection Sink - Trace Identifier Mismatch
"TCM-UNEQ": Tandem Connection Sink - Unequipped
"TIM": trace identifier mismatch (when reported as an alarm)
"TU-AIS": TU alarm indication signal
"TX_DEGRADE": transmitter degrade, including laser degrade
"TX_FAIL": transmitter failure, including laser failure
"UAT": Unavailable Time
"UNEQ": payload unequipped
"VC-AIS": VCL/VCC TP Alarm Indication Signal
"VC-RDI": VCL/VCC TP Remote Defect Indication
"VP-AIS": VPL/VPC TP Alarm Indication Signal
"VP-RDI": VPL/VPC TP Remote Defect Indication

A.5.2  CTM GateWay/CORBA Mapping—EMS

Table A-15 lists the CTM GateWay/CORBA mapping for the EMS.

Table A-15 CTM GateWay/CORBA Mapping for the EMS 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

EMS

Loss of Communication

5001

EMS

Memory Auto or Manual Backup Failure

5002

SECURITY_VIOLATION

Maximum Login Attempts Exceeded

5003

EMS

Partition 0 Free Disk Space Low

5004

EMS

Partition 1 Free Disk Space Low

5005

EMS

Partition 2 Free Disk Space Low

5006

EMS

Partition 3 Free Disk Space Low

5007

EMS

Partition 4 Free Disk Space Low

5008

EMS

Partition 5 Free Disk Space Low

5009

EMS

Partition 6 Free Disk Space Low

5010

EMS

Alarm Resync Unsuccessful

5011

EMS

Server Monitor Threshold Crossed

5012


A.5.3  CTM GateWay/CORBA Mapping—CRS-1 and XR 12000

Table A-16 lists the CTM GateWay/CORBA mapping for the CRS-1 and XR 12000.

Table A-16 CTM GateWay/CORBA Mapping for the CRS-1 and XR 12000 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

Either churn has been detected (due to link synchronization failure) or the churn state has been cleared.

36375

UNIDENTIFIED

Configuration is redistributing more than the allowable number of prefixes to the IS-IS topology. It cannot advertise some routes.

39912

UNIDENTIFIED

Set—When Standby remains in Not Ready state for a long period of time.

Cleared—When Standby is removed, reset, or in Ready state.

43040

UNIDENTIFIED

The interface hardware went up or down.

40409

UNIDENTIFIED

Reports the amount of free memory. Values are:

Set—Free memory on the node is below the reported threshold.

Clear—Free memory is above the minor threshold.

38580

UNIDENTIFIED

Values are:

Set—When some monitored disk usages are above 80%.

Cleared—When all monitored disk usages are below 80%.

38565

UNIDENTIFIED

Environmental conditions exist on a specified slot. If left unattended, it could result in loss of service or hardware damage.

37332

UNIDENTIFIED

Possible error during sizing of the NVRAM.

41431

UNIDENTIFIED

Detects the NVRAM low battery state. The data stored in NVRAM may be destroyed after powering down the board while battery is in low state.

41428

UNIDENTIFIED

Cannot get PCI device information from the PCI bus manager.

41999

UNIDENTIFIED

An alarm has occurred.

37371

UNIDENTIFIED

The card hardware went up or down.

38690

UNIDENTIFIED

The plane is down. This means that the sprayer cannot reach any destination on the plane. This is a symptom of too many fabric errors.

37970

UNIDENTIFIED

No path detected from the sprayer to the sponge.

37962


A.5.4  CTM GateWay/CORBA Mapping—MGX 8880/8850/8830

Table A-17 lists the CTM GateWay/CORBA mapping for MGX 8880/8850/8830.

Table A-17 CTM GateWay/CORBA Mapping for MGX 8880/8850/8830 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

EMS

Sync-up has not started yet

60009

EMS

Currently in sync-up

60010

EMS

Partial sync-up

60011

EMS

Sync-up failed

60012

EMS

Server in partial sync-up

60013

EMS

Server sync-up failed

60014

The following EMS alarms need to be cleared manually so "isClearable" should be set to "False" in the corresponding GateWay/CORBA alarm event.

EMS

FTP transfer failure

62401

EMS

FTP file size mismatch

62408

EMS

FTP transfer failed

62409

EMS

Upload file error

62410

EMS

Minus 2 trap

62411

EMS

Card lost trap

62412

EMS

SNMP retry exceeded

62413

EMS

FTP retry exceeded

62414

EMS

Stats file error

62416

EMS

Stats file transfer error

62417

EMS

SNMP throttle error

62418

EMS

Backoff failed

62419

EMS

SNMP timeout

62420

EMS

FTP session timeout

62421

EMS

FTP transfer timeout

62422

EMS

Unknown error

62448

EMS

Initialization error

62449

EMS

Communication error in ILOG

62452

EMS

Communication error in shared memory

62453

EMS

Communication error in CORBA

62454

EMS

NTS registration failed

62456

EMS

NTS trap loss

62457

EMS

PM error

62459

EMS

Process restarted

62502

Shelf Level Peripheral Alarms

EQPT

Above normal

60031

EQPT

Below normal

60032

EQPT

Down

60033

EQPT

Power failure

60034

Card Level Alarms: For all Supported Cards on MGX8880/8850/8830

EQPT

Front card not present

60101

EQPT

Front card failed

60102

EQPT

Front card in self test

60103

EQPT

Front card held in reset

60104

EQPT

Front card in boot

60105

EQPT

Front card mismatch

60106

EQPT

Front card unknown alarm

60107

EQPT

Front card core card mismatch

60108

EQPT

Front card failed, no backup

60109

EQPT

Front card reserved

60110

EQPT

Front card down

60111

EQPT

Front card in update mode

60112

EQPT

Front card unavailable

60113

EQPT

Front card downloading

60114

EQPT

Front card downloader

60115

EQPT

Front card downloaded

60116

EQPT

Front card locked

60117

EQPT

Front card in program mode

60118

EQPT

Front card upgrading

60119

EQPT

Front card upgraded

60120

EQPT

Front card frozen

60121

EQPT

Front card in hold mode

60122

EQPT

Front card not responding

60123

EQPT

Front card in initialization

60124

EQPT

Front card blocked

60125

EQPT

Front card removed

60126

EQPT

Primary back card not present

60201

EQPT

Primary back card in mismatch

60202

EQPT

Secondary back card not present

60301

EQPT

Secondary back card in mismatch

60302

EQPT

Primary card not present

60401

EQPT

Primary card failed

60402

EQPT

Primary card in self test

60403

EQPT

Primary card held in reset

60404

EQPT

Primary card in boot

60405

EQPT

Primary card mismatch

60406

EQPT

Primary card unknown alarm

60407

EQPT

Primary card core card mismatch

60408

EQPT

Primary card failed, no backup

60409

EQPT

Primary card reserved

60410

EQPT

Primary card down

60411

EQPT

Primary card in update mode

60412

EQPT

Primary card unavailable

60413

EQPT

Primary card downloading

60414

EQPT

Primary card downloader

60415

EQPT

Primary card downloaded

60416

EQPT

Primary card locked

60417

EQPT

Primary card in program mode

60418

EQPT

Primary card upgrading

60419

EQPT

Primary card upgraded

60420

EQPT

Primary card frozen

60421

EQPT

Primary card in hold mode

60422

EQPT

Primary card not responding

60423

EQPT

Primary card in initialization

60424

EQPT

Primary card blocked

60425

EQPT

Front card removed

60426

EQPT

Secondary card not present

60501

EQPT

Secondary card failed

60502

EQPT

Secondary card in self test

60503

EQPT

Secondary card held in reset

60504

EQPT

Secondary card in boot

60505

EQPT

Secondary card mismatch

60506

EQPT

Secondary card unknown alarm

60507

EQPT

Secondary card core card mismatch

60508

EQPT

Secondary card failed, no backup

60509

EQPT

Secondary card reserved

60510

EQPT

Secondary card down

60511

EQPT

Secondary card in update mode

60512

EQPT

Secondary card unavailable

60513

EQPT

Secondary card downloading

60514

EQPT

Secondary card downloader

60515

EQPT

Secondary card downloaded

60516

EQPT

Secondary card locked

60517

EQPT

Secondary card in program mode

60518

EQPT

Secondary card upgrading

60519

EQPT

Secondary card upgraded

60520

EQPT

Secondary card frozen

60521

EQPT

Secondary card in hold mode

60522

EQPT

Secondary card not responding

60523

EQPT

Secondary card in initialization

60524

EQPT

Redundant blocked

60525

EQPT

Secondary card removed

60526

EQPT

Controller in standby mode

60601

EQPT

License expired

60650

EQPT

License missing

60651

EQPT

Card sync-up failed

60660

EQPT

Redundant card switch over

60661

Sensor Alarms: VXSM

EQPT

Sensor less than threshold value

60670

EQPT

Sensor greater than threshold value

60671

EQPT

Sensor equal to threshold value

60672

EQPT

Sensor less than threshold value

60673

EQPT

Sensor greater than threshold value

60674

EQPT

Sensor equal to threshold value

60675

EQPT

Sensor less than threshold value

60676

EQPT

Sensor greater than threshold value

60677

EQPT

Sensor equal to threshold value

60678

Line Level Alarms
For DS1 Line: AXSM, MPSM, PXM1E, VXSM, VISM, SRME

RAI

Receiving RAI

60701

RAI

Transmitting RAI

60702

AIS

Receiving AIS

60703

AIS

Transmitting AIS

60704

OOF

Receiving OOF

60705

LOS

Receiving LOS

60706

UNIDENTIFIED

Near-End local loop in effect

60707

UNIDENTIFIED

Near-End remote loop in effect

60708

UNIDENTIFIED

Near-End remote Payload loop in effect

60709

OOF

Receiving CRC MF OOF

60710

OOF

Receiving Sig MF OOF

60711

RAI

Receiving MF RAI

60712

AIS

Receiving MF AIS

60713

UNIDENTIFIED

Far-End remote loopback

60714

UNIDENTIFIED

Detected Near-End remote loopback

60715

For DS3 Line: AXSM, MPSM, PXM1E, VXSM, SRME

UNIDENTIFIED

Receiving RAI

60801

RAI

Transmitting RAI

60802

AIS

Receiving AIS

60803

AIS

Transmitting AIS

60804

OOF

Receiving OOF

60805

LOS

Receiving LOS

60806

UNIDENTIFIED

Near-End local loop in effect

60807

UNIDENTIFIED

Near-End remote loop in effect

60808

UNIDENTIFIED

Receiving test pattern

60809

UNIDENTIFIED

Receiving LOCD

60810

UNIDENTIFIED

Receiving C-bit parity pattern

60811

For SONET Line: AXSM, MPSM, PXM1E, VXSM, SRME

AIS

Line Receiving AIS

60901

UNIDENTIFIED

Line Receiving RDI

60902

AIS

Line Transmitting AIS

60903

UNIDENTIFIED

Line Transmitting RDI

60904

LOS

Section LOS

60910

LOF

Section LOF

60911

UNIDENTIFIED

Section trace ID mismatch

60912

LOP

Path Receiving STS LOP

60920

AIS

Path Receiving STS AIS

60921

UNIDENTIFIED

Path Receiving STS RDI

60922

UNEQ

Path Unequipped

60923

UNIDENTIFIED

Path Signal Label mismatch

60924

UNIDENTIFIED

Path Trace failure

60925

AIS

Path Transmitting AIS

60926

UNIDENTIFIED

Path Transmitting RDI

60927

UNIDENTIFIED

Path Signal Receiving LOCD

60928

Line Stats Alarm
DS1/DS3: AXSM, MPSM, PXM1E, VXSM, VISM, SRME

UNIDENTIFIED

Stats Alarm, PES current 15-minute threshold exceeded

61101

UNIDENTIFIED

Stats Alarm, PES 24-hour threshold exceeded

61102

UNIDENTIFIED

Stats Alarm, PSES current 15-minute threshold exceeded

61103

UNIDENTIFIED

Stats Alarm, PSES 24-hour threshold exceeded

61104

UNIDENTIFIED

Stats Alarm, SEFS current 15-minute threshold exceeded

61105

UNIDENTIFIED

Stats Alarm, SEFS 24-hour threshold exceeded

61106

UNIDENTIFIED

Stats Alarm, UAS current 15-minute threshold exceeded

61107

UNIDENTIFIED

Stats Alarm, UAS 24-hour threshold exceeded

61108

UNIDENTIFIED

Stats Alarm, LCV current 15-minute threshold exceeded

61109

UNIDENTIFIED

Stats Alarm, LCV 24-hour threshold exceeded

61110

UNIDENTIFIED

Stats Alarm, PCV current 15-minute threshold exceeded

61111

UNIDENTIFIED

Stats Alarm, PCV 24-hour threshold exceeded

61112

UNIDENTIFIED

Stats Alarm, LES current 15-minute threshold exceeded

61113

UNIDENTIFIED

Stats Alarm, LES 24-hour threshold exceeded

61114

UNIDENTIFIED

Stats Alarm, CCV current 15-minute threshold exceeded

61115

UNIDENTIFIED

Stats Alarm, CCV 24-hour threshold exceeded

61116

UNIDENTIFIED

Stats Alarm, CES current 15-minute threshold exceeded

61117

UNIDENTIFIED

Stats Alarm, CES 24-hour threshold exceeded

61118

UNIDENTIFIED

Stats Alarm, CSES current 15-minute threshold exceeded

61119

UNIDENTIFIED

Stats Alarm, CSES 24-hour threshold exceeded

61120

SONET: AXSM, MPSM, PXM1E, VXSM, SRME

UNIDENTIFIED

Stats Alarm, SONET line, Total ESs

61201

UNIDENTIFIED

Stats Alarm, SONET line, Total SESs

61202

UNIDENTIFIED

Stats Alarm, SONET line, Total CVs

61203

UNIDENTIFIED

Stats Alarm, SONET line, Total UAs

61204

UNIDENTIFIED

Stats Alarm, SONET line, Current ESs

61205

UNIDENTIFIED

Stats Alarm, SONET line, Current SESs

61206

UNIDENTIFIED

Stats Alarm, SONET line, Current CVs

61207

UNIDENTIFIED

Stats Alarm, SONET line, Current UAs

61208

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Current ESs

61209

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Total ESs

61210

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Total SESs

61211

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Total CVs

61212

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Total UAs

61213

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Current SESs

61214

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Current CVs

61215

UNIDENTIFIED

Stats Alarm, SONET line, Far End, Current UASs

61216

UNIDENTIFIED

Stats Alarm, SONET section, Total ESs

61301

UNIDENTIFIED

Stats Alarm, SONET section, Total SESs

61302

UNIDENTIFIED

Stats Alarm, SONET section, Total SEFSs

61303

UNIDENTIFIED

Stats Alarm, SONET section, Total CVs

61304

UNIDENTIFIED

Stats Alarm, SONET section, Current ESs

61305

UNIDENTIFIED

Stats Alarm, SONET section, Current SESs

61306

UNIDENTIFIED

Stats Alarm, SONET section, Current SEFSs

61307

UNIDENTIFIED

Stats Alarm, SONET section, Current CVs

61308

UNIDENTIFIED

Stats Alarm, SONET path, Total ESs

61401

UNIDENTIFIED

Stats Alarm, SONET path, Total SESs

61402

UNIDENTIFIED

Stats Alarm, SONET path, Total CVs

61403

UNIDENTIFIED

Stats Alarm, SONET path, Total UAs

61404

UNIDENTIFIED

Stats Alarm, SONET path, Current ESs

61405

UNIDENTIFIED

Stats Alarm, SONET path, Current SESs

61406

UNIDENTIFIED

Stats Alarm, SONET path, Current CVs

61407

UNIDENTIFIED

Stats Alarm, SONET path, Current UAs

61408

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Current ESs

61409

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Total ESs

61410

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Total SESs

61411

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Total CVs

61412

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Total UAs

61413

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Current SESs

61414

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Current CVs

61415

UNIDENTIFIED

Stats Alarm, SONET path, Far End, Current UASs

61416

Line APS Alarms: AXSM, MPSM, PXM1E, VXSM, SRME

FOP_APS

APS Alarm, Channel Mismatch

61501

FOP_APS

APS Alarm, ProtectionByte Fail

61502

FOP_APS

APS Alarms, FEProtection Failure

61503

FOP_APS

APS Alarms, Mode Mismatch

61504

FOP_APS

APS Alarms, Signal Degrade

61505

FOP_APS

APS Alarms, Signal Failure

61506

FOP_APS

APS Alarms, Line Alarm

61507

FOP_APS

APS Alarms, Line Loopback

61508

FOP_APS

APS Alarms, Stdby signal Degrade

61509

FOP_APS

APS Alarms, Stdby signal Failure

61510

FOP_APS

APS Alarms, Stdby Line Alarm

61511

FOP_APS

APS Alarms, Stdby Line Loopback

61512

FOP_APS

APS Alarms, Direction Mismatch

61513

FOP_APS

APS Alarms, Wrong Request

61514

EQPT

APS Alarms, Protect BC missing

61515

EQPT

APS Alarms, Protect DC missing

61516

EQPT

APS Alarms, Working BC missing

61517

EQPT

APS Alarms, Working DC missing

61518

EQPT

APS Alarms, Working Card mismatch

61519

EQPT

APS Alarms, Protect Card mismatch

61520

FOP_APS

APS Alarms, apsRevertiveSwitchFail

61521

FOP_APS

APS Alarms, apsManulSwitchFail

61522

FOP_APS

APS Alarms, apsSDLowSwitchFail

61523

FOP_APS

APS Alarms, apsSDHighSwitchFail

61524

FOP_APS

APS Alarms, apsSFLowSwitchFail

61525

FOP_APS

APS Alarms, apsSFHighSwtichFail

61526

FOP_APS

APS Alarms, apsForceSwitchFail

61527

FOP_APS

APS Alarms, apsLockOutSwitchFail

61528

FOP_APS

APS Alarms, apslineStatusOk

61529

Port Alarms: AXSM, MPSM, PXM1E

UNIDENTIFIED

Port, not configured

61751

UNIDENTIFIED

Port, down/failure

61752

UNIDENTIFIED

Port, remote loopback

61753

UNIDENTIFIED

Port, signaling failure

61754

UNIDENTIFIED

Port, out of cell delineation

61755

UNIDENTIFIED

Port, lower layer down

61756

RPM Port Alarms: RPM, RPM-XF

UNIDENTIFIED

RPM Port, Down

62101

UNIDENTIFIED

RPM Port, Testing

62102

UNIDENTIFIED

RPM Port, Unknown

62103

UNIDENTIFIED

RPM Port, lower layer down

62104

SVC Port Alarms: AXSM, VXSM, RPM-XF, RPM

UNIDENTIFIED

SVC Port, failed

62201

UNIDENTIFIED

SVC Port, Inactive

62202

UNIDENTIFIED

SVC Port, lower layer down

62203

VISM Port Alarms: VISM

UNIDENTIFIED

VISM Port, failed

62221

UNIDENTIFIED

VISM Port, Degraded

62222

UNIDENTIFIED

VISM Port, lower layer down

62223

Aggregate Port Alarms: AXSM, MPSM, PXM1E RPM, RPM-XF

UNIDENTIFIED

Aggregate Port alarm; one or more connections on this port are in primary failure

62301

UNIDENTIFIED

Aggregate Port alarm; one or more connections on this port are in secondary failure

62302

UNIDENTIFIED

Aggregate Port alarm; one or more connections on this port are incomplete

62303

Connection Alarm: AXSM, MPSM, PXM1E, VXSM, VISM, RPM, RPM-XF

UNIDENTIFIED

Connection Alarm, Primary Failure

62601

UNIDENTIFIED

Connection Alarm, Secondary Failure

62602

UNIDENTIFIED

Incomplete Connection

62603

Card Level VXSM and VISM Alarms

UNIDENTIFIED

CAC Resources, Above high threshold value

60681

UNIDENTIFIED

CAC Resources, Above medium threshold value

60683

UNIDENTIFIED

Media Gateway Link state, pendingIs

60611

UNIDENTIFIED

Media Gateway Link state, pendingFoos

60613

UNIDENTIFIED

Media Gateway Link state, pendingGoos

60614

UNIDENTIFIED

Media Gateway Link state, outOfService

60612

UNIDENTIFIED

Media Gateway Link state, mgcDirectOos

60615

UNIDENTIFIED

RUDP Session state, Out Of Service

60631

UNIDENTIFIED

RUDP Session state, StandbyIs

60632

UNIDENTIFIED

RUDP Session state, FullIs

60633

UNIDENTIFIED

RUDP Session state, Unknown

60634

UNIDENTIFIED

Session Group state, Out Of Service

60641

UNIDENTIFIED

Session Group state, Unknown

60642

UNIDENTIFIED

Session Set state, Out Of Service

60691

UNIDENTIFIED

Session Set state, StandbyIs

60692

UNIDENTIFIED

Session Set state, FullI

60693

UNIDENTIFIED

Session Set state, Unknown

60694

UNIDENTIFIED

MGC in Redundancy group, inactive

60211

UNIDENTIFIED

MGC communication state, inactive

60221

UNIDENTIFIED

RTP Connection state, failed

60231

UNIDENTIFIED

CID state, failed

60241

UNIDENTIFIED

MTP Link Set Active

66001

UNIDENTIFIED

MTP Link Set Inactive

66002

UNIDENTIFIED

MTP Link Set Inhibited

66003

UNIDENTIFIED

MTP Link Set Unhibited

66004

UNIDENTIFIED

MTP Link Set Shut

66005

UNIDENTIFIED

MTP Link Set No Shut

66006

UNIDENTIFIED

MTP Link Active

66007

UNIDENTIFIED

MTP Link Inactive

66008

UNIDENTIFIED

MTP Link Inhibited

66009

UNIDENTIFIED

MTP Link Unhibited

66010

UNIDENTIFIED

MTP Link Shut

66011

UNIDENTIFIED

MTP Link No Shut

66012

UNIDENTIFIED

MTP Signaling Gateway Route Available

66013

UNIDENTIFIED

MTP Signaling Gateway Route Unavailable

66014

UNIDENTIFIED

MTP Signaling Gateway Route Restricted

66015

UNIDENTIFIED

L3UA ASP Active

66016

UNIDENTIFIED

L3UA ASP Inactive

66017

UNIDENTIFIED

L3UA ASP Down

66018

UNIDENTIFIED

L3UA ASP Undefined

66019

UNIDENTIFIED

L3UA AS Active

66020

UNIDENTIFIED

L3UA AS Inactive

66021

UNIDENTIFIED

L3UA AS Down

66022

UNIDENTIFIED

L3UA AS Pending

66023

UNIDENTIFIED

L3UA AS Undefined

66024

UNIDENTIFIED

DPNSS DLC Active

66025

UNIDENTIFIED

DPNSS DLC Inactive

66026

UNIDENTIFIED

Gateway Voice Quality Alert

66027

UNIDENTIFIED

Gateway VBD Call Quality Alert

66028

UNIDENTIFIED

Gateway Voice Quality Alert for IP-IP

66029

UNIDENTIFIED

Gateway VQM Trap Queue Full

66030

UNIDENTIFIED

System Resource Utilization Threshold Exceeded

66031

UNIDENTIFIED

System Resource Utilization Normal

66032

UNIDENTIFIED

System Resource Utilization Medium Level Exceeded

66033

UNIDENTIFIED

Zero Percent Call Reduce Rate Reached

66034

UNIDENTIFIED

Maximum Call Reduce Rate Reached

66035

UNIDENTIFIED

Gateway Drop Call Starts

66036

UNIDENTIFIED

Gateway Drop Call Alert Cleared

66037

UNIDENTIFIED

Gateway Overload Normal

66038

UNIDENTIFIED

Gateway Overload Threshold Exceeded

66039

Line Level VISM and VXSM Alarms

UNIDENTIFIED

Endpoint state, failed

60251

UNIDENTIFIED

Endpoint state, degraded

60252

UNIDENTIFIED

LAPD state, inactive

61591

UNIDENTIFIED

LAPD Trunk state, inactive

61531

UNIDENTIFIED

LAPD Trunk state, unknown

61532


A.5.5  CTM GateWay/CORBA Mapping—ONS 15216

A.5.5.1  ONS 15216 OADM

Table A-18 lists the alarms for ONS 15216 OADM Release 2.0.

Table A-18 CTM GateWay/CORBA Alarms for the ONS 15216 OADM 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

LOS

Add Channel Signal Loss

8501

LOS

Drop Channel Signal Loss

8502

EQPT

Add and Drop Channels Are Out of Tolerance

8503

EQPT

Add Channel Signal Is Too Weak and VOA Cannot Adjust It To Match the Drop Signal

8504

EQPT

A_POWER Unit Failed

8505

EQPT

B_POWER Unit Failed

8506


Table A-19 lists the alarms for the ONS 15216 EDFA Releases 2.2 and 2.4.

Table A-19 CTM GateWay/CORBA Alarms for the ONS EDFA Releases 2.2 and 2.4 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

Unknown Alarm

8601

EQPT

Excessive Pump1 Current

8602

EQPT

Excessive Pump2 Current

8603

EQPT

Excessive Pump1 Laser Temperature

8604

EQPT

Excessive Pump2 Laser Temperature

8605

EQPT

Loss of Output Power

8606

EQPT

Loss of Input Power

8607

EQPT

Gain Out of Range

8608

EQPT

Case Temperature Out of Range

8609

EQPT

A_POWER Unit Failed

8610

EQPT

B_POWER Unit Failed

8611

EQPT

Database Backup

8612

EQPT

Database Restore

8613

EQPT

Cutover Reset

8614

EQPT

Software Load

8615

EQPT

Software Reset

8616


A.5.5.2  ONS 15216 EDFA3

Table A-20 lists the alarms for the ONS 15216 EDFA3 Release 1.0.

Table A-20 CTM GateWay/CORBA Alarms for ONS 15216 EDFA Release 1.0 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

Unknown Alarm

8701

EQPT

Gain Degrade High

8702

EQPT

Gain Degrade Low

8703

EQPT

Laser 1 Bias Degrade

8704

EQPT

Laser 2 Bias Degrade

8705

EQPT

Laser 1 Bias Fail

8706

EQPT

Laser 2 Bias Fail

8707

EQPT

Power Degrade High LINE1TX Port

8708

EQPT

Power Degrade Low LINE1TX Port

8709

EQPT

Power Fail Low LINE1RX Port

8710

EQPT

Power Fail Low LINE1TX Port

8711

EQPT

Power Fail Low LINE2RX Port

8712

EQPT

VOA Degrade High

8713

EQPT

VOA Degrade Low

8714

EQPT

VOA Fail High

8715

EQPT

Case Temperature Out of Range

8716

EQPT

Fiber Temperature Out of Range

8717

EQPT

Excessive Pump 1 Temperature

8718

EQPT

Excessive Pump 2 Temperature

8719

EQPT

Backup/Restore In Progress

8720

EQPT

Data Integrity Fault

8721

EQPT

Equipment Failure

8722

EQPT

Exceeding Memory Capacity

8723

EQPT

Exceeding Flash File System Capacity

8724

EQPT

Module Communication Failure

8725

EQPT

Power Bus A Alarm

8726

EQPT

Power Bus B Alarm

8727


A.5.6  CTM GateWay/CORBA Mapping—ONS 15302, ONS15305, and ONS15305 CTC

Table A-21 lists the CTM GateWay/CORBA mapping for ONS 15302 and ONS 15305.

Table A-21 CTM GateWay/CORBA Mapping for ONS 15302, ONS 15305, and
ONS 15305 CTC 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

ONS1530x condition unknown

19000

AIS

Alarm indication signal

19001

AIS

Alarm indication signal network side

19002

LOF

Alarm indication signal customer side

19003

LOF

Loss of frame alignment

19004

LOF

Loss of frame alignment network side

19005

LOF

Loss of frame alignment customer side

19006

LOP

Loss of pointer

19007

LOS

Loss of signal

19008

BER_SD

Degraded signal defect

19009

LOM

Loss of multiframe alignment

19010

RAI

Remote defect indication

19011

TIM

Trace identifier mismatch

19012

PLM

Payload mismatch

19013

UNEQ

Unequipped

19014

BER_SF

Excessive error defect

19015

UNIDENTIFIED

Communication subsystem failure

19016

SSF

Server signal failure

19017

UNIDENTIFIED

Alarm condition detected on an alarm input port

19018

EQPT

Device main unit failure

19019

EQPT

High temperature alarm

19020

EQPT

Fan failure

19021

EQPT

Power input failure

19022

EQPT

Power output failure

19023

EQPT

Module mismatch

19024

EQPT

Module removed

19025

EQPT

Module failure

19026

UNIDENTIFIED

MSP signalling problem

19027

UNIDENTIFIED

Power module failure

19028

UNIDENTIFIED

LAN port is not working

19029

UNIDENTIFIED

WAN port is not working

19030

UNIDENTIFIED

Too large delay on WAN channel

19031

UNIDENTIFIED

Sequence number fail on WAN channel

19032

UNIDENTIFIED

No synchronization source available

19033

UNIDENTIFIED

Defecting HW impacting internal T0 clock

19034

UNIDENTIFIED

No T4 synchronization source available with QL >= QL min

19035

UNIDENTIFIED

Inventory failure

19036

UNIDENTIFIED

Diagnostic failure

19037

UNIDENTIFIED

DXC inlet failure

19038

UNIDENTIFIED

DXC inlet bit error

19039

UNIDENTIFIED

Card isolated

19040

UNIDENTIFIED

Card anomaly

19041

UNIDENTIFIED

Hot swap failure

19042

UNIDENTIFIED

Power input failure

19043

UNIDENTIFIED

Transmit degrade on laser

19044

UNIDENTIFIED

Transmit fail on laser

19045

UNIDENTIFIED

Port activated without mapping to an available VC-12

19046

UNIDENTIFIED

Differential VC12 delay for the WAN port is greater than +/- 2ms

19047

UNIDENTIFIED

Rx buffer overflow in LAN or link interface

19048

UNIDENTIFIED

Interport queue overflow in LAN or link interface

19049

UNIDENTIFIED

Reset of the router/bridge required

19050

UNIDENTIFIED

Device aborted FTP session

19051

UNIDENTIFIED

Automatic switchover to backup link, main link fault

19052

UNIDENTIFIED

Overflow layer 2 forward table

19053

UNIDENTIFIED

Connection failed: Frame Relay Switch and WanGate

19054

UNIDENTIFIED

Connection establish: Frame Relay Switch and WanGate

19055

UNIDENTIFIED

Error occurred during initialization

19056

UNIDENTIFIED

Overflow in the client table

19057

UNIDENTIFIED

Server not responding to dispatcher polling

19058

UNIDENTIFIED

SNMP SET request was rejected

19059

UNIDENTIFIED

Ping sequence completed

19060

UNIDENTIFIED

Backup taken over for main server or server up after failure

19061

UNIDENTIFIED

DHCP failed to allocate IP address to requesting host

19062

UNIDENTIFIED

Overflow IGMP table

19063

UNIDENTIFIED

Overflow PIM table

19064

UNIDENTIFIED

Overflow condition in Routing table

19065

UNIDENTIFIED

OpenGate IPX RIP table overflow

19066

UNIDENTIFIED

OpenGate IPX SAP table overflow

19067

UNIDENTIFIED

FACS state ne bt with operation blockAndReport

19068

UNIDENTIFIED

Zero hop routing connections table overflow

19069

UNIDENTIFIED

No available IP virtual address

19070

UNIDENTIFIED

Virtual IP address appeared as a source IP

19071

UNIDENTIFIED

Source IP address sent an ARP specifying a virtual IP

19072

UNIDENTIFIED

PPP link got an unrecognized secret

19073

UNIDENTIFIED

FR DLCI status change

19074

UNIDENTIFIED

CHAP failed communication

19075

UNIDENTIFIED

IP SFFT overflow

19076

UNIDENTIFIED

IP NFFT overflow

19077

UNIDENTIFIED

IPX SFFT overflow

19078

UNIDENTIFIED

IPX NFFT overflow

19079

UNIDENTIFIED

IPM FFT overflow

19080

UNIDENTIFIED

PAP failed communication

19081

UNIDENTIFIED

Automatic switchover to backup link, main link fault

19082

UNIDENTIFIED

Informational event

19083

UNIDENTIFIED

T0SyncSwitch

19084

UNIDENTIFIED

T0QIFailed

19085

UNIDENTIFIED

T0QIDnu

19086

UNIDENTIFIED

SwitchToProt

19087

UNIDENTIFIED

SwitchToWork

19088

UNIDENTIFIED

MspComTimeOut

19089

UNIDENTIFIED

MspComOverruled

19090

UNIDENTIFIED

Loop closed

19091

UNIDENTIFIED

Loop opened

19092

UNIDENTIFIED

Link up

19093

UNIDENTIFIED

Link down

19094

UNIDENTIFIED

The communication link has come up

19095

UNIDENTIFIED

Failure in communication link

19096

UNIDENTIFIED

Addressee of a protocol message not properly authenticated

19097

UNIDENTIFIED

Reinitializing; configuration or the protocol entity implementation may be altered

19098

UNIDENTIFIED

Reinitializing; neither configuration nor protocol entity implementation altered

19099

UNIDENTIFIED

RMON alarm has crossed the rising threshold

19100

UNIDENTIFIED

RMON alarm has crossed the falling threshold

19101

UNIDENTIFIED

Loss of an adjacency with a PIM neighbor

19102

UNIDENTIFIED

Device finished TFTP transaction

19103

UNIDENTIFIED

Device initiated TFTP transaction

19104

UNIDENTIFIED

Auto configuration completed successfully

19105

UNIDENTIFIED

VLAN port dynamically added

19106

UNIDENTIFIED

VLAN port dynamically changed

19107

UNIDENTIFIED

Physical description device changed

19108

UNIDENTIFIED

Port transition from learning to forwarding

19109

UNIDENTIFIED

Port transition from forwarding to learning

19110

UNIDENTIFIED

Packet drop due to the QoS policy

19111

UNIDENTIFIED

Packet forwarded based on the QoS policy

19112

UNIDENTIFIED

Protection link activated

19113

UNIDENTIFIED

Working link activated

19114

UNIDENTIFIED

MSP command timeout

19115

UNIDENTIFIED

MSP command overruled

19116

UNIDENTIFIED

Loss of external synchronization

19117

UNIDENTIFIED

ONS1530x condition unknown

19999


A.5.7  CTM GateWay/CORBA Mapping—ONS15327, ONS 15454 SONET, and ONS 15454 SDH, R4.0 and R4.1

Table A-22 lists the CTM GateWay/CORBA mapping for the ONS 15327, ONS 15454 SONET, and ONS 15454 SDH Release 4.0 and Release 4.1.

Table A-22 CTM GateWay/CORBA Mapping for the ONS 15327, ONS 15454 SONET, and ONS 15454 SDH R4.0 and R4.1 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

Normal Condition

25000

ENV

Failure Detected External to the NE

25001

ENV

External Error

25002

UNIDENTIFIED

Excessive Switching

25003

UNIDENTIFIED

Incoming Failure Condition

25004

AIS

Alarm Indication Signal

25005

AIS

Alarm Indication Signal - Line

25006

AIS

Alarm Indication Signal - Path

25007

FOP_APS

APS Channel Failure

25008

FOP_APS

Byte Failure

25009

FOP_APS

Protection Switching Channel Match Failure

25010

FOP_APS

Automatic Protection Switch Mode Mismatch

25011

FOP_APS

Far End Protection Line Failure

25012

UNIDENTIFIED

Bipolar Violation

25013

UNIDENTIFIED

Carrier Loss on the LAN

25014

UNIDENTIFIED

STS Concatenation Error

25015

UNIDENTIFIED

Excess Collisions on the LAN

25016

UNIDENTIFIED

Facility Failure

25017

UNIDENTIFIED

Far End Block Error

25018

LOF

Loss of Frame

25019

LOP

Loss of Pointer

25020

LOP

Loss of Pointer - Path

25021

LOS

Loss of Signal

25022

UNIDENTIFIED

Out of Frame

25023

UNIDENTIFIED

Path Selector failure

25024

RAI

Remote Alarm Indication

25025

RAI

Remote Failure Indication

25026

RAI

Remote Failure Indication - Line

25027

RAI

Remote Failure Indication - Path

25028

BER_SD

Signal Degrade

25029

UNIDENTIFIED

Severely Errored Frame

25030

UNIDENTIFIED

Invalid Alarm

25031

BER_SF

Signal Failure

25032

UNIDENTIFIED

Signal Label Mismatch Failures

25033

UNIDENTIFIED

Payload Defect Indication

25034

UNIDENTIFIED

Payload Defect Indication - Path

25035

PLM

Payload Label Mismatch - Path

25036

UNEQ

Unequipped - Path

25037

UNIDENTIFIED

Loss of Synchronization

25038

UNIDENTIFIED

Out of Synchronization

25039

UNIDENTIFIED

Primary Synchronization Reference Failure

25040

UNIDENTIFIED

Secondary Synchronization Reference Failure

25041

UNIDENTIFIED

Third Synchronization Reference Failure

25042

UNIDENTIFIED

Fourth Synchronization Reference Failure

25043

UNIDENTIFIED

Fifth Synchronization Reference Failure

25044

UNIDENTIFIED

Sixth Synchronization Reference Failure

25045

UNIDENTIFIED

Outgoing Failure Condition

25046

RAI

Remote Defect Indication - Line

25047

RAI

Remote Defect Indication - Path

25048

UNIDENTIFIED

Free Running Synchronization Mode

25049

UNIDENTIFIED

Holdover Synchronization Mode

25050

EQPT

Internal Fault

25051

UNIDENTIFIED

Internal Error

25052

UNIDENTIFIED

Internal Message Error

25053

UNIDENTIFIED

Mismatch of Equipment And Attributes

25054

UNIDENTIFIED

Watchdog Timer Timeout

25055

ENV

Software Fault or Failure

25056

ENV

Software Fault - Data Integrity Fault

25057

UNIDENTIFIED

Program Failure

25058

EQPT

Control Equipment Failure

25059

EQPT

Control Processor Failure

25060

EQPT

Working Memory Failure

25061

EQPT

Interconnection Equipment Failure

25062

EQPT

Time Slot Interchange Equipment Failure

25063

EQPT

Equipment Failure

25064

EQPT

High Temperature

25065

EQPT

Facility Termination Equipment Failure

25066

EQPT

Automatic Laser Shutdown

25067

UNIDENTIFIED

Failure to Release From Protection

25068

EQPT

Receiver Failure

25069

EQPT

Transmit Failure

25070

UNIDENTIFIED

Failure to Switch to Protection

25071

UNIDENTIFIED

Equipment Unit Plug-In

25072

UNIDENTIFIED

Internal Power Failure

25073

UNIDENTIFIED

Fuse Alarm

25074

UNIDENTIFIED

Synchronization Unit Failure

25075

UNIDENTIFIED

Synchronization Switching Equipment Failure

25076

EQPT

Equipment Unit Unplugged

25077

EQPT

Manually Caused Abnormal Condition

25078

UNIDENTIFIED

Manual Alarm Cutoff

25079

UNIDENTIFIED

Procedural Error

25080

EQPT

Improper Removal

25081

UNIDENTIFIED

Protection Unit Not Available

25082

UNIDENTIFIED

Protection Switch

25083

UNIDENTIFIED

Recovery or Service Protection Action Has Been Initiated

25084

UNIDENTIFIED

Automatic System Reset

25085

UNIDENTIFIED

Cold Restart

25086

UNIDENTIFIED

Forced Switch Back to Working

25087

UNIDENTIFIED

Forced Switch to Protection

25088

UNIDENTIFIED

Initialization Initiated

25089

UNIDENTIFIED

Lockout of Protection

25090

UNIDENTIFIED

Lockout of Working

25091

UNIDENTIFIED

Manual System Reset

25092

UNIDENTIFIED

Manual Switch to Internal Clock

25093

UNIDENTIFIED

Manual Switch to Primary Reference

25094

UNIDENTIFIED

Manual Switch to Secondary Reference

25095

UNIDENTIFIED

Manual Switch to Third Reference

25096

UNIDENTIFIED

Manual Switch to Fourth Reference

25097

UNIDENTIFIED

Manual Switch to Fifth Reference

25098

UNIDENTIFIED

Manual Switch to Sixth Reference

25099

UNIDENTIFIED

Manual Switch Back to Working

25100

UNIDENTIFIED

Manual Switch to Protection

25101

UNIDENTIFIED

Powerfail Restart

25102

UNIDENTIFIED

Software Download In Progress

25103

UNIDENTIFIED

Switch to Internal Clock

25104

UNIDENTIFIED

Switch to Primary Reference

25105

UNIDENTIFIED

Switch to Secondary Reference

25106

UNIDENTIFIED

Switch to Third Reference

25107

UNIDENTIFIED

Switch to Fourth Reference

25108

UNIDENTIFIED

Switch to Fifth Reference

25109

UNIDENTIFIED

Switch to Sixth Reference

25110

UNIDENTIFIED

Switched Back to Working

25111

UNIDENTIFIED

Switched to Protection

25112

UNIDENTIFIED

Warm Restart

25113

UNIDENTIFIED

Ring is in Wait to Restore State

25114

EQPT

Primary Nonvolatile Backup Memory Failure

25115

EQPT

Secondary Nonvolatile Backup Memory Failure

25116

EQPT

Control Bus Failure

25117

EQPT

Control Communications Equipment Failure

25118

UNIDENTIFIED

Loopback

25119

UNIDENTIFIED

Loopback, Network

25120

UNIDENTIFIED

Loopback, Terminal

25121

EQPT

Fan Failure

25122

DCC_FAILURE

SDCC Termination Failure

25123

UNIDENTIFIED

Loopback Facility

25124

EQPT

Payload Bus Failure to I/O Slot 1 (XCON Slot 8)

25125

EQPT

Payload Bus Failure to I/O Slot 2 (XCON Slot 8)

25126

EQPT

Payload Bus Failure to I/O Slot 3 (XCON Slot 8)

25127

EQPT

Payload Bus Failure to I/O Slot 4 (XCON Slot 8)

25128

EQPT

Payload Bus Failure to I/O Slot 5 (XCON Slot 8)

25129

EQPT

Payload Bus Failure to I/O Slot 6 (XCON Slot 8)

25130

EQPT

Payload Bus Failure to I/O Slot 12 (XCON Slot 8)

25131

EQPT

Payload Bus Failure to I/O Slot 13 (XCON Slot 8)

25132

EQPT

Payload Bus Failure to I/O Slot 14 (XCON Slot 8)

25133

EQPT

Payload Bus Failure to I/O Slot 15 (XCON Slot 8)

25134

EQPT

Payload Bus Failure to I/O Slot 16 (XCON Slot 8)

25135

EQPT

Payload Bus Failure to I/O Slot 17 (XCON Slot 8)

25136

EQPT

Payload Bus Failure to I/O Slot 1 (XCON Slot 10)

25137

EQPT

Payload Bus Failure to I/O Slot 2 (XCON Slot 10)

25138

EQPT

Payload Bus Failure to I/O Slot 3 (XCON Slot 10)

25139

EQPT

Payload Bus Failure to I/O Slot 4 (XCON Slot 10)

25140

EQPT

Payload Bus Failure to I/O Slot 5 (XCON Slot 10)

25141

EQPT

Payload Bus Failure to I/O Slot 6 (XCON Slot 10)

25142

EQPT

Payload Bus Failure to I/O Slot 12 (XCON Slot 10)

25143

EQPT

Payload Bus Failure to I/O Slot 13 (XCON Slot 10)

25144

EQPT

Payload Bus Failure to I/O Slot14 (XCON Slot 10)

25145

EQPT

Payload Bus Failure to I/O Slot15 (XCON Slot 10)

25146

EQPT

Payload Bus Failure to I/O Slot16 (XCON Slot 10)

25147

EQPT

Payload Bus Failure to I/O Slot17 (XCON Slot 10)

25148

EQPT

Control Bus 1 Failure

25149

EQPT

Control Bus 2 Failure

25150

EQPT

Invalid MAC Address

25151

EQPT

Board Failure

25152

EQPT

Diagnostics Failure

25153

EQPT

Medium Access Control Failure

25154

UNIDENTIFIED

Duplicate Node ID

25155

UNIDENTIFIED

Failure to Switch to Protection - Ring

25156

UNIDENTIFIED

Failure to Switch to Protection - Span

25157

UNIDENTIFIED

Manual Switch Back to Working - Ring

25158

UNIDENTIFIED

Manual Switch Back to Working - Span

25159

UNIDENTIFIED

Manual Switch to Protection - Ring

25160

UNIDENTIFIED

Manual Switch to Protection - Span

25161

UNIDENTIFIED

Forced Switch Back to Working - Ring

25162

UNIDENTIFIED

Forced Switch Back to Working - Span

25163

UNIDENTIFIED

Forced Switch to Protection - Ring

25164

UNIDENTIFIED

Forced Switch to Protection - Span

25165

UNIDENTIFIED

Lockout of Protection - Ring

25166

UNIDENTIFIED

Lockout of Protection - Span

25167

UNIDENTIFIED

Lockout of Working - Ring

25168

UNIDENTIFIED

Lockout of Working - Span

25169

UNIDENTIFIED

Ring Is Squelching Traffic

25170

FOP_APS

Inconsistent APS Code

25171

FOP_APS

Node ID Mismatch

25172

FOP_APS

Default K Byte

25173

FOP_APS

Connection Loss

25174

EQPT

TCC A to Shelf Slot 1 (DROP 1) Communication Failure

25175

EQPT

TCC A to Shelf Slot 2 (DROP 2) Communication Failure

25176

EQPT

TCC A to Shelf Slot 3 (DROP 3) Communication Failure

25177

EQPT

TCC A to Shelf Slot 4 (DROP 4) Communication Failure

25178

EQPT

TCC A to Shelf Slot 5 (TRUNK 1) Communication Failure

25179

EQPT

TCC A to Shelf Slot 6 (TRUNK 2) Communication Failure

25180

EQPT

TCC A to Shelf Slot 7 (TCC A) Communication Failure

25181

EQPT

TCC A to Shelf Slot 8 (XCON A) Communication Failure

25182

EQPT

TCC A to Shelf Slot 9 (AIC) Communication Failure

25183

EQPT

TCC A to Shelf Slot 10 (XCON B) Communication Failure

25184

EQPT

TCC A to Shelf Slot 11 (TCC B) Communication Failure

25185

EQPT

TCC A to Shelf Slot 12 (TRUNK 3) Communication Failure

25186

EQPT

TCC A to Shelf Slot 13 (TRUNK 4) Communication Failure

25187

EQPT

TCC A to Shelf Slot 14 (DROP 5) Communication Failure

25188

EQPT

TCC A to Shelf Slot 15 (DROP 6) Communication Failure

25189

EQPT

TCC A to Shelf Slot 16 (DROP 7) Communication Failure

25190

EQPT

TCC A to Shelf Slot 17 (DROP 8) Communication Failure

25191

EQPT

TCC A to DCC A Processor Communication Failure

25192

EQPT

TCC B to Shelf Slot 1 (DROP 1) Communication Failure

25193

EQPT

TCC B to Shelf Slot 2 (DROP 2) Communication Failure

25194

EQPT

TCC B to Shelf Slot 3 (DROP 3) Communication Failure

25195

EQPT

TCC B to Shelf Slot 4 (DROP 4) Communication Failure

25196

EQPT

TCC B to Shelf Slot 5 (TRUNK 1) Communication Failure

25197

EQPT

TCC B to Shelf Slot 6 (TRUNK 2) Communication Failure

25198

EQPT

TCC B to Shelf Slot 7 (TCC A) Communication Failure

25199

EQPT

TCC B to Shelf Slot 8 (XCON A) Communication Failure

25200

EQPT

TCC B to Shelf Slot 9 (AIC) Communication Failure

25201

EQPT

TCC B to Shelf Slot 10 (XCON B) Communication Failure

25202

EQPT

TCC B to Shelf Slot 11 (TCC B) Communication Failure

25203

EQPT

TCC B to Shelf Slot 12 (TRUNK 3) Communication Failure

25204

EQPT

TCC B to Shelf Slot 13 (TRUNK 4) Communication Failure

25205

EQPT

TCC B to Shelf Slot 14 (DROP 5) Communication Failure

25206

EQPT

TCC B to Shelf Slot 15 (DROP 6) Communication Failure

25207

EQPT

TCC B to Shelf Slot 16 (DROP 7) Communication Failure

25208

EQPT

TCC B to Shelf Slot 17 (DROP 8) Communication Failure

25209

EQPT

TCC B to DCC B Processor Communication Failure

25210

UNIDENTIFIED

Fast Start Synchronization Mode

25211

FOP_APS

Improper APS Code

25212

UNIDENTIFIED

BLSR out of Sync

25213

AIS

Alarm Indication Signal - VT

25214

RAI

Remote Failure Indication - VT

25215

PLM

Signal Label Mismatch Failure - Payload Label Mismatch - VT

25216

UNEQ

Signal Label Mismatch Failure - Unequipped - VT

25217

UNIDENTIFIED

Peer State Mismatch

25218

EQPT

Facility Termination Equipment - Receiver Missing

25219

EQPT

Facility Termination Equipment - Transmitter Missing

25220

LOP

Loss of Pointer - VT

25221

UNIDENTIFIED

Embedded Operations Channel Failure - Link Down

25222

UNIDENTIFIED

Failed to Receive Synchronization Status Message

25223

UNIDENTIFIED

Synchronization Status Messages are Disabled on this Interface

25224

UNIDENTIFIED

Primary Reference Source - Stratum 1 Traceable

25225

UNIDENTIFIED

Synchronized - Traceability Unknown

25226

UNIDENTIFIED

Stratum 2 Traceable

25227

UNIDENTIFIED

Transit Node Clock Traceable

25228

UNIDENTIFIED

Stratum 3E Traceable

25229

UNIDENTIFIED

Stratum 3 Traceable

25230

UNIDENTIFIED

SONET Minimum Clock Traceable

25231

UNIDENTIFIED

Stratum 4 Traceable

25232

UNIDENTIFIED

Do Not Use for Synchronization

25233

UNIDENTIFIED

Reserved for Network Synchronization Use

25234

UNIDENTIFIED

Failure to Switch to Protection - Path

25235

UNIDENTIFIED

Manual Switch of Working Facility - Equipment to Protection - Path

25236

UNIDENTIFIED

Working Facility - Equipment Forced to Switch to Protection - Path

25237

UNIDENTIFIED

Lockout of Protection - Path

25238

UNIDENTIFIED

Automatic UPSR Switch caused by AIS

25239

UNIDENTIFIED

Automatic UPSR Switch caused by LOP

25240

UNIDENTIFIED

Automatic UPSR Switch caused by UNEQ

25241

UNIDENTIFIED

Automatic UPSR Switch caused by PDI

25242

UNIDENTIFIED

Automatic UPSR Switch caused by SFBER

25243

UNIDENTIFIED

Automatic UPSR Switch caused by SDBER

25244

UNIDENTIFIED

DS3 Idle Condition

25245

UNIDENTIFIED

DS1 Loopback due to FEAC Command

25246

UNIDENTIFIED

DS1 Loopback Command Sent to Far End

25247

UNIDENTIFIED

DS3 Loopback due to FEAC Command

25248

UNIDENTIFIED

DS3 Loopback Command Sent to Far End

25249

UNIDENTIFIED

DS2 Loopback due to Far End Command

25250

UNIDENTIFIED

DS2 Loopback Command Sent to Far End

25251

ENV

Far End AIS

25252

UNIDENTIFIED

Far End Multiple DS1 LOS Detected on DS3

25253

ENV

Far End DS1 Equipment Failure - Non-Service Affecting

25254

ENV

Far End DS1 Equipment Failure - Service Affecting

25255

ENV

Far End Single DS1 LOS

25256

ENV

Far End DS3 Equipment Failure - Non-Service Affecting

25257

ENV

Far End DS3 Equipment Failure - Service Affecting

25258

ENV

Far End Common Equipment Failure - Non-Service Affecting

25259

UNIDENTIFIED

Far End IDLE

25260

ENV

Far End LOS

25261

ENV

Far End LOF

25262

UNIDENTIFIED

Performance Monitor Threshold Crossing Alert

25263

UNIDENTIFIED

Ethernet Bridge is New Root of Spanning Tree

25264

UNIDENTIFIED

Ethernet Bridge Topology Change

25265

UNIDENTIFIED

BLSR Tables Resynchronized

25266

ENV

System Reboot

25267

UNIDENTIFIED

Manual Switch Request on Facility - Equipment

25268

UNIDENTIFIED

Forced Switch Request on Facility or Equipment

25269

UNIDENTIFIED

Lockout Switch Request on Facility - Equipment

25270

UNIDENTIFIED

RMON Histories and Alarms Reset Reboot

25271

UNIDENTIFIED

RMON Alarm

25272

LOS

Video Interface Card Loss of Video IF Signal

25273

LOS

VIC Loss of Video Baseband Signal

25274

LOS

VIC Loss of Audio FM Signal

25275

LOS

VIC Loss of Audio Baseband Channel 1 Signal

25276

LOS

VIC Loss of Audio Baseband Channel 2 Signal

25277

LOS

VIC Loss of Audio Baseband Channel 3 Signal

25278

LOS

VIC Loss of Audio Baseband Channel 4 Signal

25279

TIM

STS Path Trace Identifier Mismatch

25280

ENV

NE Power Failure at Connector A

25281

ENV

NE Power Failure at Connector B

25282

UNIDENTIFIED

Free Memory on Card Very Low

25283

UNIDENTIFIED

Free Memory on Card Near Zero

25284

UNIDENTIFIED

Exercise Request on Ring

25285

UNIDENTIFIED

Exercise Request on Span

25286

UNIDENTIFIED

Squelching Path

25287

UNIDENTIFIED

Extra Traffic Preempted

25288

UNIDENTIFIED

Far End LockOut of Working - Ring

25289

UNIDENTIFIED

Far End LockOut of Working - Span

25290

UNIDENTIFIED

Far End Lockout of Protection - Ring

25291

UNIDENTIFIED

Far End Lockout of Protection - All Spans

25292

UNIDENTIFIED

Far End Working Facility Forced to Switch to Protection - Ring

25293

UNIDENTIFIED

Far End Working Facility Forced to Switch to Protection - Span

25294

UNIDENTIFIED

Far End Manual Switch of Working Facility to Protection- Ring

25295

UNIDENTIFIED

Far End Manual Switch of Working Facility to Protection- Span

25296

UNIDENTIFIED

Far End Exercising Ring

25297

UNIDENTIFIED

Far End Exercising Span

25298

ENV

Far End BER Threshold Passed for Signal Failure - Ring

25299

ENV

Far End BER Threshold Passed for Signal Failure - Span

25300

ENV

Far End BER Threshold Passed for Signal Degrade - Ring

25301

ENV

Far End BER Threshold Passed for Signal Degrade - Span

25302

ENV

APS Channel - Far End Protection Line Signal Degrade

25303

UNIDENTIFIED

Ring Switch Is Active on the East Side

25304

UNIDENTIFIED

Ring Switch Is Active on the West Side

25305

UNIDENTIFIED

Span Switch Is Active on the East Side

25306

UNIDENTIFIED

Span Switch Is Active on the West Side

25307

UNIDENTIFIED

Unidirectional Full Pass-Through is Active

25308

UNIDENTIFIED

Bidirectional Full Pass-Through is Active

25309

UNIDENTIFIED

K Bytes Pass-Through is Active

25310

UNIDENTIFIED

Ring is Segmented

25311

UNIDENTIFIED

Ring Topology is Under Construction

25312

UNIDENTIFIED

Lockout of Protection - All Spans

25313

UNIDENTIFIED

Far End of Fiber is provisioned with Different Ring ID

25314

UNIDENTIFIED

Both Ends of Fiber provisioned as East or Both as West

25315

SECURITY_VIOLATION

Securit - Invalid Login - See Audit Trail

25316

UNIDENTIFIED

Autonomous Messages Inhibited

25317

UNIDENTIFIED

Traffic Storm on LAN; LAN Temporarily Disabled

25318

UNIDENTIFIED

REPT^DBCHG Messages Inhibited

25319

SECURITY_VIOLATION

Security - User ID Has Expired

25320

EQPT

Partial Fan Failure

25321

UNIDENTIFIED

Force Switch Request on Ring

25322

UNIDENTIFIED

Force Switch Request on Span

25323

UNIDENTIFIED

Lockout Switch Request on Ring

25324

UNIDENTIFIED

Lockout Switch Request on Span

25325

UNIDENTIFIED

Manual Switch Request on Ring

25326

UNIDENTIFIED

Manual Switch Request on Span

25327

EQPT

Peer-to-Peer Slot Communication Failure

25328

EQPT

Peer-to-Peer Slot Communication Failure

25329

EQPT

TCC A to Shelf Slot Communication Failure

25330

EQPT

TCC B to Shelf Slot Communication Failure

25331

EQPT

Interconnection Equipment Failure - Working XC Payload Bus

25332

EQPT

Interconnection Equipment Failure - Protect XC Payload Bus

25333

EQPT

Inhibit Switch To Protect Request on Equipment

25334

EQPT

Inhibit Switch to Working Request on Equipment

25335

BER_SD

BER Threshold Exceeded for Signal Degrade - Line

25336

BER_SD

BER Threshold Exceeded for Signal Degrade - Path

25337

BER_SF

BER Threshold Exceeded for Signal Failure - Line

25338

BER_SF

BER Threshold Exceeded for Signal Failure - Path

25339

UNIDENTIFIED

Exercising Ring Successfully

25340

UNIDENTIFIED

Exercising Span Successfully

25341

UNIDENTIFIED

Span is in Wait to Restore State

25342

EQPT

Peer Card Not Responding

25343

UNIDENTIFIED

Exercise Request on Ring Failed

25344

UNIDENTIFIED

Exercise Request on Span Failed

25345

UNIDENTIFIED

Far End Lockout of Protection - Span

25346

EQPT

Manufacturing Data Memory (EEPROM) Failure

25347

EQPT

Replaceable Equipment/Unit is Missing

25348

ENV

Software Download Failure

25349

TIM

TIM Section - Trace Identifier Mismatch Failure

25350

AIS

AIS - Multiplex Section - Alarm Indication Signal

25351

RAI

RFI - Multiplex Section - Remote Failure/Alarm Indication

25352

TIM

TIM High Order - Trace Identifier Mismatch Failure

25353

AU_AIS

AIS - Administration Unit - Alarm Indication Signal

25354

LOP

LOP - Administration Unit - Loss of Pointer

25355

UNEQ

SLMF - Unequipped High Order - Path Unequipped

25356

PLM

SLMF - PLM High Order - Path Label Mismatch

25357

RAI

RFI - High Order - Remote Failure/Alarm Indication

25358

LOP

LOP - Tributary Unit - Loss of Pointer

25359

TU-AIS

AIS - Tributary Unit - Alarm Indication Signal

25360

UNEQ

SLMF - Unequipped Low Order - Path Unequipped

25361

PLM

SLMF - PLM Low Order - Path Label Mismatch

25362

TIM

TIM Low Order - Trace Identifier Mismatch Failure

25363

RAI

RFI - Low Order - Remote Failure/Alarm Indication

25364

UNIDENTIFIED

G811 - Primary Reference Clock Traceable

25365

UNIDENTIFIED

G812 - Transit Node Clock Traceable

25366

UNIDENTIFIED

G812 - Local Node Clock Traceable

25367

UNIDENTIFIED

G813 - Synchronous Equipment Timing Source Traceable

25368

UNIDENTIFIED

E1 Loopback due to FEAC Command

25369

UNIDENTIFIED

E1 Loopback Command Sent to Far End

25370

UNIDENTIFIED

E3 Loopback due to FEAC Command

25371

ENV

Far End Multiple E1 LOS Detected on E3

25372

ENV

Far End E1 Equipment Failure Non-Service Affecting

25373

ENV

Far End E1 Equipment Failure Service Affecting

25374

ENV

Far End Single E1 LOS

25375

ENV

Far End E3 Equipment Failure Service Affecting

25376

UNIDENTIFIED

E3 Loopback Command Sent to Far End

25377

ENV

Far End E3 Equipment Failure Non-Service Affecting

25378

ENV

Low Voltage - Battery A

25379

ENV

High Voltage - Battery A

25380

ENV

Low Voltage - Battery B

25381

ENV

High Voltage - Battery B

25382

UNIDENTIFIED

Procedural Error - MS-SP Ring out of Sync

25383

UNIDENTIFIED

MS-SP Ring Tables Resynchronized

25384

UNIDENTIFIED

Automatic SNCP Switch caused by AIS

25385

UNIDENTIFIED

Automatic SNCP Switch caused by LOP

25386

UNIDENTIFIED

Automatic SNCP Switch caused by UNEQ

25387

UNIDENTIFIED

Automatic SNCP Switch caused by PDI

25388

UNIDENTIFIED

Automatic SNCP Switch caused by SFBER

25389

UNIDENTIFIED

Automatic SNCP Switch caused by SDBER

25390

UNIDENTIFIED

STM Concatenation Error

25391

UNIDENTIFIED

E3 Idle Condition

25392

UNIDENTIFIED

IOS Config Copy Failed

25393

UNIDENTIFIED

IOS Config Copy In Progress

25394

UNIDENTIFIED

Alarms Suppressed by User Command

25399

UNIDENTIFIED

Alarms Suppressed for Maintenance

25400

UNIDENTIFIED

N/A

25401

UNIDENTIFIED

Synchronization Reference Frequency Out of Bounds

25402

UNIDENTIFIED

Ether Tx Excess Flow Ctrl

25403

UNIDENTIFIED

Ether Tx Oversubscribed

25404

UNIDENTIFIED

Transport Layer Failure

25405

UNIDENTIFIED

Ether Rx Excess Flow Ctrl

25406

UNIDENTIFIED

Ether Rx Oversubscribed

25407

UNIDENTIFIED

Ether Tx Underrun

25408

UNIDENTIFIED

SNTP Host Failure

25409

UNIDENTIFIED

DS3 Frame Format Mismatch

25410

UNIDENTIFIED

Alarms/Events Suppressed for this Object

25411

BER_SD

BER Threshold Exceeded for Signal Degrade - High Order

25412

BER_SF

BER Threshold Exceeded for Signal Failure - High Order

25413

BER_SD

BER Threshold Exceeded for Signal Degrade - Low Order

25414

BER_SF

BER Threshold Exceeded for Signal Failure - Low Order

25415

UNIDENTIFIED

Failure to Switch to Protection - High Order Path

25416

UNIDENTIFIED

Failure to Switch to Protection - Low Order Path

25417

UNIDENTIFIED

Wait to Restore

25418

ENV

Extreme High Voltage - Battery A

25419

ENV

Extreme Low Voltage - Battery A

25420

ENV

Extreme High Voltage - Battery B

25421

ENV

Extreme Low Voltage - Battery B

25422

UNIDENTIFIED

Switching Matrix Module Failure

25423

UNIDENTIFIED

Signaling Unable to Set Up Circuit

25424

UNIDENTIFIED

RSVP Hello FSM to Neighbor Down

25425

UNIDENTIFIED

LMP Hello FSM to Control Channel Down

25426

UNIDENTIFIED

LMP Neighbor Discovery Has Failed

25427

UNIDENTIFIED

Unauthorized Incoming Signaling Request

25428

UNIDENTIFIED

Signaled Circuit Going Down

25429

UNIDENTIFIED

Autonomous PM Report Message Inhibited

25430

EQPT

I/O Slot to XCON Communication Failure

25431

UNIDENTIFIED

Forced Switch to Primary Reference

25432

UNIDENTIFIED

Forced Switch to Secondary Reference

25433

UNIDENTIFIED

Forced Switch to Third Reference

25434

UNIDENTIFIED

Forced Switch to Internal Clock

25435

LOM

LOF - Administration Unit - Loss of Multi Frame

25436

UNIDENTIFIED

Admin Logout of User

25438

UNIDENTIFIED

User Locked Out

25439

UNIDENTIFIED

Admin Lockout of User

25440

UNIDENTIFIED

Admin Lockout Clear

25441

SECURITY_VIOLATION

Security - Invalid Login - Username - See Audit Log

25442

SECURITY_VIOLATION

Security - Invalid Login - Password - See Audit Log

25443

SECURITY_VIOLATION

Security - Invalid Login - Locked Out - See Audit Log

25444

SECURITY_VIOLATION

Security - Invalid Login - Already Logged On - See Audit Log

25445

UNIDENTIFIED

Login of User

25446

UNIDENTIFIED

Automatic Logout of Idle User

25447

UNIDENTIFIED

Logout of User

25448

UNIDENTIFIED

Cross-connect Loopback

25451

UNIDENTIFIED

Error in Startup Config

25454

UNIDENTIFIED

No Startup Config

25455

EQPT

Laser Approaching End of Life

25456

UNIDENTIFIED

Database Backup Failed

25457

UNIDENTIFIED

Database Restore Failed

25458

UNIDENTIFIED

8B10B out of Sync

25459

AIS

ODUk - Alarm Indication Signal

25460

AIS

OTUk - Alarm Indication Signal

25461

UNIDENTIFIED

OTUk - Backward Defect Indicator

25462

UNIDENTIFIED

ODUk - Backward Defect Indicator

25463

UNIDENTIFIED

FEC Uncorrected Word

25464

UNIDENTIFIED

GCC Embedded Operation Channel Failure

25465

UNIDENTIFIED

OTUk - Incoming Alignment Error

25466

UNIDENTIFIED

ODUk- Locked Defect - PM

25467

LOM

Loss of Multi-Frame

25468

UNIDENTIFIED

ODUk - Open Connection Indication

25469

PLM

Payload Type Identifier Mismatch

25470

TIM

ODUk - Trail Trace Identifier Mismatch

25471

TIM

OTUk - Trail Trace Identifier Mismatch

25472

EQPT

Equipment High Laser Bias

25473

EQPT

Equipment High Laser Temp

25474

EQPT

Equipment High Laser Peltier

25475

EQPT

Equipment High Rx Power

25476

EQPT

Equipment High Tx Power

25477

EQPT

Equipment High Rx Temperature

25478

EQPT

Equipment Low Tx Temperature

25479

EQPT

Equipment High Transceiver Voltage

25480

EQPT

Equipment Low Laser Bias

25481

EQPT

Equipment Low Laser Temp

25482

EQPT

Equipment Low Laser Peltier

25483

EQPT

Equipment Low Rx Power

25484

EQPT

Equipment Low Tx Power

25485

EQPT

Equipment Low Transceiver Voltage

25486

EQPT

Equipment Rx Locked

25487

EQPT

Equipment Squelched

25488

EQPT

Equipment Tx Locked

25489

BER_SF

OTUk - Signal Failure

25490

BER_SF

ODUk - Signal Failure

25491

BER_SD

OTUk - Signal Degrade

25492

BER_SD

ODUk - Signal Degrade

25493

UNIDENTIFIED

Pluggable Port Missing

25494

UNIDENTIFIED

Pluggable Port Rate Mismatch

25495

SECURITY_VIOLATION

Pluggable Port Security Code Mismatch

25496

UNIDENTIFIED

Tci Not Selected

25497

UNIDENTIFIED

Tci 1 Clock Failure

25498

UNIDENTIFIED

ODUk - Backward Defect Indicator

25499

UNIDENTIFIED

ODUk - Backward Defect Indicator

25500

UNIDENTIFIED

ODUk - Backward Defect Indicator

25501

UNIDENTIFIED

ODUk - Open Connection Indication

25504

UNIDENTIFIED

ODUk - Locked Defect - TCM2

25505

AIS

ODUk - Alarm Indication Signal

25506

TIM

ODUk - Trail Trace Identifier Mismatch

25507

BER_SD

ODUk - Signal Degrade - TCM2

25508

BER_SF

ODUk - Signal Failure - TCM2

25509

UNIDENTIFIED

ODUk - Open Connection Indication

25510

UNIDENTIFIED

ODUk - Locked Defect - TCM1

25511

AIS

ODUk - Alarm Indication Signal

25512

TIM

ODUk - Trail Trace Identifier Mismatch

25513

BER_SD

ODUk - Signal Degrade - TCM1

25514

BER_SF

ODUk - Signal Failure - TCM1

25515

LOF

OTUk - Loss of Frame

25516

UNIDENTIFIED

Tci 2 Clock Failure

25517

UNIDENTIFIED

Audit Log 80 Percent Full

25518

UNIDENTIFIED

Module Communication Failure

25519

UNIDENTIFIED

Need to Save Running Config

25520

UNIDENTIFIED

Audit Log 100 Percent Full - Oldest Records will be Lost

25521

UNIDENTIFIED

Standby Database out of Sync

25522

EQPT

Redundant Power Capability Lost

25523

EQPT

Equipment Wavelength Mismatch

25524

UNIDENTIFIED

DSP Communication Failure

25525

UNIDENTIFIED

DSP Failure

25526

UNIDENTIFIED

Loss of Channel

25527

UNIDENTIFIED

FEC Mismatch

25528

UNIDENTIFIED

LAN Connection Polarity Reversed

25529

UNIDENTIFIED

Enhanced Remote Failure Indication - Path - Server

25530

UNIDENTIFIED

Enhanced Remote Failure Indication - Path - Connectivity

25531

UNIDENTIFIED

Enhanced Remote Failure Indication - Path - Payload

25532

SECURITY_VIOLATION

Security Violation Detected

25533

UNIDENTIFIED

Syslog Messages

28000

UNIDENTIFIED

Configuration Events

28001

UNIDENTIFIED

LinkUp/LinkDown Trap

28002

UNIDENTIFIED

Cold/Warn Start Trap

28003

SECURITY_VIOLATION

Authentication Failure Notification

28004


A.5.8  CTM GateWay/CORBA Mapping—ONS 15310 CL, ONS15327, ONS 15454 SONET, and ONS 15454 SDH R5.0

Table A-23 lists the CTM GateWay/CORBA mapping for the ONS 15310 CL, ONS 15327, ONS 15454 SONET, and ONS 15454 SDH Release 5.0.

Table A-23 CTM GateWay/CORBA Mapping for the ONS 15310 CL, ONS 15327, ONS 15454 SONET, and ONS 15454 SDH R5.0 

TMF Mapping
NE Native Probable Cause
CTM Internal Index (Not Reported in the Notification)

UNIDENTIFIED

Normal Condition

25000

ENV

Failure Detected External to the NE

25001

ENV

External Error

25002

UNIDENTIFIED

Excessive Switching

25003

UNIDENTIFIED

Incoming Failure Condition

25004

AIS

Alarm Indication Signal

25005

AIS

Alarm Indication Signal - Line

25006

AIS

Alarm Indication Signal - Path

25007

FOP_APS

APS Channel Failure

25008

FOP_APS

Byte Failure

25009

FOP_APS

Protection Switching Channel Match Failure

25010

FOP_APS

Automatic Protection Switch Mode Mismatch

25011

FOP_APS

Far End Protection Line Failure

25012

UNIDENTIFIED

Bipolar Violation

25013

UNIDENTIFIED

Carrier Loss on the LAN

25014

UNIDENTIFIED

STS Concatenation Error

25015

UNIDENTIFIED

Excess Collisions on the LAN

25016

UNIDENTIFIED

Facility Failure

25017

UNIDENTIFIED

Far End Block Error

25018

LOF

Loss of Frame

25019

LOP

Loss of Pointer

25020

LOP

Loss of Pointer - Path

25021

LOS

Loss of Signal

25022

UNIDENTIFIED

Out of Frame

25023

UNIDENTIFIED

Path Selector Failure

25024

RAI

Remote Alarm Indication

25025

RAI

Remote Failure Indication

25026

RAI

Remote Failure Indication - Line

25027

RAI

Remote Failure Indication - Path

25028

BER_SD

Signal Degrade

25029

UNIDENTIFIED

Severely Errored Frame

25030

UNIDENTIFIED

Invalid Alarm

25031

BER_SF

Signal Failure

25032

UNIDENTIFIED

Signal Label Mismatch Failures

25033

UNIDENTIFIED

Payload Defect Indication

25034

UNIDENTIFIED

Payload Defect Indication - Path

25035

PLM

Payload Label Mismatch - Path

25036

UNEQ

Unequipped - Path

25037

UNIDENTIFIED

Loss of Synchronization

25038

UNIDENTIFIED

Out of Synchronization

25039

UNIDENTIFIED

Primary Synchronization Reference Failure

25040

UNIDENTIFIED

Secondary Synchronization Reference Failure

25041

UNIDENTIFIED

Third Synchronization Reference Failure

25042

UNIDENTIFIED

Fourth Synchronization Reference Failure

25043

UNIDENTIFIED

Fifth Synchronization Reference Failure

25044

UNIDENTIFIED

Sixth Synchronization Reference Failure

25045

UNIDENTIFIED

Outgoing Failure Condition

25046

RAI

Remote Defect Indication - Line

25047

RAI

Remote Defect Indication - Path

25048

UNIDENTIFIED

Free Running Synchronization Mode

25049

UNIDENTIFIED

Holdover Synchronization mode

25050

EQPT

Internal Fault

25051

UNIDENTIFIED

Internal Error

25052

UNIDENTIFIED

Internal Message Error

25053

UNIDENTIFIED

Mismatch of Equipment and Attributes

25054

UNIDENTIFIED

Watchdog Timer Timeout

25055

ENV

Software Fault or Failure

25056

ENV

Software Fault - Data Integrity Fault

25057

UNIDENTIFIED

Program Failure

25058

EQPT

Control Equipment Failure

25059

EQPT

Control Processor Failure

25060

EQPT

Working Memory Failure

25061

EQPT

Interconnection Equipment Failure

25062

EQPT

Time Slot Interchange Equipment Failure

25063

EQPT

Equipment Failure

25064

EQPT

High Temperature

25065

EQPT

Facility Termination Equipment Failure

25066

EQPT

Automatic Laser Shutdown

25067

UNIDENTIFIED

Failure to Release From Protection

25068

EQPT

Receiver Failure

25069

EQPT

Transmit Failure

25070

UNIDENTIFIED

Failure to Switch to Protection

25071

UNIDENTIFIED

Equipment Unit Plug-In

25072

UNIDENTIFIED

Internal Power Failure

25073

UNIDENTIFIED

Fuse Alarm

25074

UNIDENTIFIED

Synchronization Unit Failure

25075

UNIDENTIFIED

Synchronization Switching Equipment Failure

25076

EQPT

Equipment Unit Unplugged

25077

EQPT

Manually Caused Abnormal Condition

25078

UNIDENTIFIED

Manual Alarm Cutoff

25079

UNIDENTIFIED

Procedural Error

25080

EQPT

Improper Removal

25081

UNIDENTIFIED

Protection Unit Not Available

25082

UNIDENTIFIED

Protection Switch

25083

UNIDENTIFIED

Recovery or Service Protection Action Has been Initiated

25084

UNIDENTIFIED

Automatic System Reset

25085

UNIDENTIFIED

Cold Restart

25086

UNIDENTIFIED

Forced Switch Back to Working

25087

UNIDENTIFIED

Forced Switch to Protection

25088

UNIDENTIFIED

Initialization Initiated

25089

UNIDENTIFIED

Lockout of Protection

25090

UNIDENTIFIED

Lockout of Working

25091

UNIDENTIFIED

Manual System Reset

25092

UNIDENTIFIED

Manual Switch to Internal Clock

25093

UNIDENTIFIED

Manual Switch to Primary Reference

25094

UNIDENTIFIED

Manual Switch to Secondary Reference

25095

UNIDENTIFIED

Manual Switch to Third Reference

25096

UNIDENTIFIED

Manual Switch to Fourth Reference

25097

UNIDENTIFIED

Manual Switch to Fifth Reference

25098

UNIDENTIFIED

Manual Switch to Sixth Reference

25099

UNIDENTIFIED

Manual Switch Back to Working

25100

UNIDENTIFIED

Manual Switch to Protection

25101

UNIDENTIFIED

Powerfail Restart

25102

UNIDENTIFIED

Software Download In Progress

25103

UNIDENTIFIED

Switch to Internal Clock

25104

UNIDENTIFIED

Switch to Primary Reference

25105

UNIDENTIFIED

Switch to Secondary Reference

25106

UNIDENTIFIED

Switch to Third Reference

25107

UNIDENTIFIED

Switch to Fourth Reference

25108

UNIDENTIFIED

Switch to Fifth Reference

25109

UNIDENTIFIED

Switch to Sixth Reference

25110

UNIDENTIFIED

Switched Back to Working

25111

UNIDENTIFIED

Switched to Protection

25112

UNIDENTIFIED

Warm Restart

25113

UNIDENTIFIED

Ring is in Wait to Restore State

25114

EQPT

Primary Nonvolatile Backup Memory Failure

25115

EQPT

Secondary Nonvolatile Backup Memory Failure

25116

EQPT

Control Bus Failure

25117

EQPT

Control Communications Equipment Failure

25118

UNIDENTIFIED

Loopback

25119

UNIDENTIFIED

Loopback, Network

25120

UNIDENTIFIED

Loopback, Terminal

25121

EQPT

Fan Failure

25122

DCC_FAILURE

SDCC Termination Failure

25123

UNIDENTIFIED

Loopback Facility

25124

EQPT

Payload Bus Failure to I/O Slot 1 (XCON Slot 8)

25125

EQPT

Payload Bus Failure to I/O Slot 2 (XCON Slot 8)

25126

EQPT

Payload Bus Failure to I/O Slot 3 (XCON Slot 8)

25127

EQPT

Payload Bus Failure to I/O Slot 4 (XCON Slot 8)

25128

EQPT

Payload Bus Failure to I/O Slot 5 (XCON Slot 8)

25129

EQPT

Payload Bus Failure to I/O Slot 6 (XCON Slot 8)

25130

EQPT

Payload Bus Failure to I/O Slot 12 (XCON Slot 8)

25131

EQPT

Payload Bus Failure to I/O Slot 13 (XCON Slot 8)

25132

EQPT

Payload Bus Failure to I/O Slot 14 (XCON Slot 8)

25133

EQPT

Payload Bus Failure to I/O Slot 15 (XCON Slot 8)

25134

EQPT

Payload Bus Failure to I/O Slot 16 (XCON Slot 8)

25135

EQPT

Payload Bus Failure to I/O Slot 17 (XCON Slot 8)

25136

EQPT

Payload Bus Failure to I/O Slot 1 (XCON Slot 10)

25137

EQPT

Payload Bus Failure to I/O Slot 2 (XCON Slot 10)

25138

EQPT

Payload Bus Failure to I/O Slot 3 (XCON Slot 10)

25139

EQPT

Payload Bus Failure to I/O Slot 4 (XCON Slot 10)

25140

EQPT

Payload Bus Failure to I/O Slot 5 (XCON Slot 10)

25141

EQPT

Payload Bus Failure to I/O Slot 6 (XCON Slot 10)

25142

EQPT

Payload Bus Failure to I/O Slot 12 (XCON Slot 10)

25143

EQPT

Payload Bus Failure to I/O Slot 13 (XCON Slot 10)

25144

EQPT

Payload Bus Failure to I/O Slot14 (XCON Slot 10)

25145

EQPT

Payload Bus Failure to I/O Slot15 (XCON Slot 10)

25146

EQPT

Payload Bus Failure to I/O Slot16 (XCON Slot 10)

25147

EQPT

Payload Bus Failure to I/O Slot17(XCON Slot 10)

25148

EQPT

Control Bus 1 Failure

25149

EQPT

Control Bus 2 Failure

25150

EQPT

Invalid MAC Address

25151

EQPT

Board Failure

25152

EQPT

Diagnostics Failure

25153

EQPT

Medium Access Control Failure

25154

UNIDENTIFIED

Duplicate Node ID

25155

UNIDENTIFIED

Failure to Switch to Protection - Ring

25156

UNIDENTIFIED

Failure to Switch to Protection - Span

25157

UNIDENTIFIED

Manual Switch Back to Working - Ring

25158

UNIDENTIFIED

Manual Switch Back to Working - Span

25159

UNIDENTIFIED

Manual Switch to Protection - Ring

25160

UNIDENTIFIED

Manual Switch to Protection - Span

25161

UNIDENTIFIED

Forced Switch Back to Working - Ring

25162

UNIDENTIFIED

Forced Switch Back to Working - Span

25163

UNIDENTIFIED

Forced Switch to Protection - Ring

25164

UNIDENTIFIED

Forced Switch to Protection - Span

25165

UNIDENTIFIED

Lockout of Protection - Ring

25166

UNIDENTIFIED

Lockout of Protection - Span

25167

UNIDENTIFIED

Lockout of Working - Ring

25168

UNIDENTIFIED

Lockout of Working - Span

25169

UNIDENTIFIED

Ring is Squelching Traffic

25170

FOP_APS

Inconsistent APS Code

25171

FOP_APS

Node ID Mismatch

25172

FOP_APS

Default K Byte

25173

FOP_APS

Connection Loss

25174

EQPT

TCC A to Shelf Slot 1 (DROP 1) Communication Failure

25175

EQPT

TCC A to Shelf Slot 2 (DROP 2) Communication Failure

25176

EQPT

TCC A to Shelf Slot 3 (DROP 3) Communication Failure

25177

EQPT

TCC A to Shelf Slot 4 (DROP 4) Communication Failure

25178

EQPT

TCC A to Shelf Slot 5 (TRUNK 1) Communication Failure

25179

EQPT

TCC A to Shelf Slot 6 (TRUNK 2) Communication Failure

25180

EQPT

TCC A to Shelf Slot 7 (TCC A) Communication Failure

25181

EQPT

TCC A to Shelf Slot 8 (XCON A) Communication Failure

25182

EQPT

TCC A to Shelf Slot 9 (AIC) Communication Failure

25183

EQPT

TCC A to Shelf Slot 10 (XCON B) Communication Failure

25184

EQPT

TCC A to Shelf Slot 11 (TCC B) Communication Failure

25185

EQPT

TCC A to Shelf Slot 12 (TRUNK 3) Communication Failure

25186

EQPT

TCC A to Shelf Slot 13 (TRUNK 4) Communication Failure

25187

EQPT

TCC A to Shelf Slot 14 (DROP 5) Communication Failure

25188

EQPT

TCC A to Shelf Slot 15 (DROP 6) Communication Failure

25189

EQPT

TCC A to Shelf Slot 16 (DROP 7) Communication Failure

25190

EQPT

TCC A to Shelf Slot 17 (DROP 8) Communication Failure

25191

EQPT

TCC A to DCC A Processor Communication Failure

25192

EQPT

TCC B to Shelf Slot 1 (DROP 1) Communication Failure

25193

EQPT

TCC B to Shelf Slot 2 (DROP 2) Communication Failure

25194

EQPT

TCC B to Shelf Slot 3 (DROP 3) Communication Failure

25195

EQPT

TCC B to Shelf Slot 4 (DROP 4) Communication Failure

25196

EQPT

TCC B to Shelf Slot 5 (TRUNK 1) Communication Failure

25197

EQPT

TCC B to Shelf Slot 6 (TRUNK 2) Communication Failure

25198

EQPT

TCC B to Shelf Slot 7 (TCC A) Communication Failure

25199

EQPT

TCC B to Shelf Slot 8 (XCON A) Communication Failure

25200

EQPT

TCC B to Shelf Slot 9 (AIC) Communication Failure

25201

EQPT

TCC B to Shelf Slot 10 (XCON B) Communication Failure

25202

EQPT

TCC B to Shelf Slot 11 (TCC B) Communication Failure

25203

EQPT

TCC B to Shelf Slot 12 (TRUNK 3) Communication Failure

25204

EQPT

TCC B to Shelf Slot 13 (TRUNK 4) Communication Failure

25205

EQPT

TCC B to Shelf Slot 14 (DROP 5) Communication Failure

25206

EQPT

TCC B to Shelf Slot 15 (DROP 6) Communication Failure

25207

EQPT

TCC B to Shelf Slot 16 (DROP 7) Communication Failure

25208

EQPT

TCC B to Shelf Slot 17 (DROP 8) Communication Failure

25209

EQPT

TCC B to DCC B Processor Communication Failure

25210

UNIDENTIFIED

Fast Start Synchronization Mode

25211

FOP_APS

Improper APS Code

25212

UNIDENTIFIED

BLSR out of Sync

25213

AIS

Alarm Indication Signal - VT

25214

RAI

Remote Failure Indication - VT

25215

PLM

Signal Label Mismatch Failure - Payload Label Mismatch - VT

25216

UNEQ

Signal Label Mismatch Failure - Unequipped - VT

25217

UNIDENTIFIED

Peer State Mismatch

25218

EQPT

Facility Termination Equipment - Receiver Missing

25219

EQPT

Facility Termination Equipment - Transmitter Missing

25220

LOP

Loss of Pointer - VT

25221

UNIDENTIFIED

Embedded Operations Channel Failure - Link Down

25222

UNIDENTIFIED

Failed to Receive Synchronization Status Message

25223

UNIDENTIFIED

Synchronization Status Messages are Disabled on this Interface

25224

UNIDENTIFIED

Primary Reference Source - Stratum 1 Traceable

25225

UNIDENTIFIED

Synchronized - Traceability Unknown

25226

UNIDENTIFIED

Stratum 2 Traceable

25227

UNIDENTIFIED

Transit Node Clock Traceable

25228

UNIDENTIFIED

Stratum 3E Traceable

25229

UNIDENTIFIED

Stratum 3 Traceable

25230

UNIDENTIFIED

SONET Minimum Clock Traceable

25231

UNIDENTIFIED

Stratum 4 Traceable

25232

UNIDENTIFIED

Do Not Use for Synchronization

25233

UNIDENTIFIED

Reserved for Network Synchronization Use

25234

UNIDENTIFIED

Failure to Switch to Protection - Path

25235

UNIDENTIFIED

Manual Switch of Working Facility - Equipment to Protection - Path

25236

UNIDENTIFIED

Working Facility - Equipment Forced to Switch to Protection - Path

25237

UNIDENTIFIED

Lockout of Protection - Path

25238

UNIDENTIFIED

Automatic UPSR Switch caused by AIS

25239

UNIDENTIFIED

Automatic UPSR Switch caused by LOP

25240

UNIDENTIFIED

Automatic UPSR Switch caused by UNEQ

25241

UNIDENTIFIED

Automatic UPSR Switch caused by PDI

25242

UNIDENTIFIED

Automatic UPSR Switch caused by SFBER

25243

UNIDENTIFIED

Automatic UPSR Switch caused by SDBER

25244

UNIDENTIFIED

DS3 Idle Condition

25245

UNIDENTIFIED

DS1 Loopback due to FEAC Command

25246

UNIDENTIFIED

DS1 Loopback Command sent to Far End

25247

UNIDENTIFIED

DS3 Loopback due to FEAC Command

25248

UNIDENTIFIED

DS3 Loopback Command sent to Far End

25249

UNIDENTIFIED

DS2 Loopback due to Far End Command

25250

UNIDENTIFIED

DS2 Loopback Command sent to Far End

25251

ENV

Far End AIS

25252

UNIDENTIFIED

Far End Multiple DS1 LOS Detected on DS3

25253

ENV

Far End DS1 Equipment Failure - Non-Service Affecting

25254

ENV

Far End DS1 Equipment Failure - Service Affecting

25255

ENV

Far End Single DS1 LOS

25256

ENV

Far End DS3 Equipment Failure - Non-Service Affecting

25257

ENV

Far End DS3 Equipment Failure - Service Affecting

25258

ENV

Far End Common Equipment Failure - Non-Service Affecting

25259

UNIDENTIFIED

Far End IDLE

25260

ENV

Far End LOS

25261

ENV

Far End LOF

25262

UNIDENTIFIED

Performance Monitor Threshold Crossing Alert

25263

UNIDENTIFIED

Ethernet Bridge is New Root of Spanning Tree

25264

UNIDENTIFIED

Ethernet Bridge Topology Change

25265

UNIDENTIFIED

BLSR Tables Resynchronized

25266

ENV

System Reboot

25267

UNIDENTIFIED

Manual Switch Request on Facility - Equipment

25268

UNIDENTIFIED

Forced Switch Request on Facility or Equipment

25269

UNIDENTIFIED

Lockout Switch Request on Facility - Equipment

25270

UNIDENTIFIED

RMON Histories and Alarms Reset Reboot

25271

UNIDENTIFIED

RMON Alarm

25272

LOS

Video Interface Card Loss of Video IF Signal

25273

LOS

VIC Loss of Video Baseband Signal

25274

LOS

VIC Loss of Audio FM Signal

25275

LOS

VIC Loss of Audio Baseband Channel 1 Signal

25276

LOS

VIC Loss of Audio Baseband Channel 2 Signal

25277

LOS

VIC Loss of Audio Baseband Channel 3 Signal

25278

LOS

VIC Loss of Audio Baseband Channel 4 Signal

25279

TIM

STS Path Trace Identifier Mismatch

25280

ENV

NE Power Failure at Connector A

25281

ENV

NE Power Failure at Connector B

25282

UNIDENTIFIED

Free Memory on Card Very Low

25283

UNIDENTIFIED

Free Memory on Card Near Zero

25284

UNIDENTIFIED

Exercise Request on Ring

25285

UNIDENTIFIED

Exercise Request on Span

25286

UNIDENTIFIED

Squelching Path

25287

UNIDENTIFIED

Extra Traffic Preempted

25288

UNIDENTIFIED

Far End LockOut of Working - Ring

25289

UNIDENTIFIED

Far End LockOut of Working - Span

25290

UNIDENTIFIED

Far End Lockout of Protection - Ring

25291

UNIDENTIFIED

Far End Lockout of Protection - All Spans

25292

UNIDENTIFIED

Far End Working Facility Forced to Switch to Protection - Ring

25293

UNIDENTIFIED

Far End Working facility Forced to Switch to Protection - Span

25294

UNIDENTIFIED

Far End Manual Switch of Working Facility to Protection- Ring

25295

UNIDENTIFIED

Far End Manual Switch of Working Facility to Protection- Span

25296

UNIDENTIFIED

Far End Exercising Ring

25297

UNIDENTIFIED

Far End Exercising Span

25298

ENV

Far End BER Threshold Passed for Signal Failure - Ring

25299

ENV

Far End BER Threshold Passed for Signal Failure - Span

25300

ENV

Far End BER Threshold Passed for Signal Degrade - Ring

25301

ENV

Far End BER Threshold Passed for Signal Degrade - Span

25302

ENV

APS Channel - Far End Protection Line Signal Degrade

25303

UNIDENTIFIED

Ring Switch is Active on the East Side

25304

UNIDENTIFIED

Ring Switch is Active on the West Side

25305

UNIDENTIFIED

Span Switch is Active on the East Side

25306

UNIDENTIFIED

Span Switch is Active on the West Side

25307

UNIDENTIFIED

Unidirectional Full Pass-Through is Active

25308

UNIDENTIFIED

Bidirectional Full Pass-Through is Active

25309

UNIDENTIFIED

K Bytes Pass-Through isActive

25310

UNIDENTIFIED

Ring is Segmented

25311

UNIDENTIFIED

Ring Topology is Under Construction

25312

UNIDENTIFIED

Lockout of Protection - All Spans

25313

UNIDENTIFIED

Far End of Fiber is Provisioned with Different Ring ID

25314

UNIDENTIFIED

Both Ends of Fiber Provisioned as East or Both as West

25315

SECURITY_VIOLATION

Security - Invalid Login - See Audit Trail

25316

UNIDENTIFIED

Autonomous Messages Inhibited

25317

UNIDENTIFIED

Traffic Storm on LAN; LAN Temporarily Disabled

25318

UNIDENTIFIED

REPT^DBCHG Messages Inhibited

25319

SECURITY_VIOLATION

Security - User ID Has Expired

25320

EQPT

Partial Fan Failure

25321

UNIDENTIFIED

Force Switch Request on Ring

25322

UNIDENTIFIED

Force Switch Request on Span

25323

UNIDENTIFIED

Lockout Switch Request on Ring

25324

UNIDENTIFIED

Lockout Switch Request on Span

25325

UNIDENTIFIED

Manual Switch Request on Ring

25326

UNIDENTIFIED

Manual Switch Request on Span

25327

EQPT

Peer-to-Peer Slot Communication Failure

25328

EQPT

Peer-to-Peer Slot Communication Failure

25329

EQPT

TCC A to Shelf Slot Communication Failure

25330

EQPT

TCC B to Shelf Slot Communication Failure

25331

EQPT

Interconnection Equipment Failure - Working XC Payload Bus

25332

EQPT

Interconnection Equipment Failure - Protect XC Payload Bus

25333

EQPT

Inhibit Switch to Protect Request on Equipment

25334

EQPT

Inhibit Switch to Working Request on Equipment

25335

BER_SD

BER Threshold Exceeded for Signal Degrade - Line

25336

BER_SD

BER Threshold Exceeded for Signal Degrade - Path

25337

BER_SF

BER Threshold Exceeded for Signal Failure - Line

25338

BER_SF

BER Threshold Exceeded for Signal Failure - Path

25339

UNIDENTIFIED

Exercising Ring Successfully

25340

UNIDENTIFIED

Exercising Span Successfully

25341

UNIDENTIFIED

Span is in Wait to Restore State

25342

EQPT

Peer Card Not Responding

25343

UNIDENTIFIED

Exercise Request on Ring Failed

25344

UNIDENTIFIED

Exercise Request on Span Failed

25345

UNIDENTIFIED

Far End Lockout of Protection - Span

25346

EQPT

Manufacturing Data Memory (EEPROM) Failure

25347

EQPT

Replaceable Equipment/Unit is Missing

25348

ENV

Software Download Failure

25349

TIM

TIM Section - Trace Identifier Mismatch Failure

25350

AIS

AIS - Multiplex Section - Alarm Indication Signal

25351

RAI

RFI - Multiplex Section - Remote Failure/Alarm Indication

25352

TIM

TIM High Order - Trace Identifier Mismatch Failure

25353

AU_AIS

AIS - Administration Unit - Alarm Indication Signal

25354

LOP

LOP - Administration Unit - Loss of Pointer

25355

UNEQ

SLMF - Unequipped High Order - Path Unequipped

25356

PLM

SLMF - PLM High Order - Path Label Mismatch

25357

RAI

RFI - High Order - Remote Failure/Alarm Indication

25358

LOP

LOP - Tributary Unit - Loss of Pointer

25359

TU-AIS

AIS - Tributary Unit - Alarm Indication Signal

25360

UNEQ

SLMF - Unequipped Low Order - Path Unequipped

25361

PLM

SLMF - PLM Low Order - Path Label Mismatch

25362

TIM

TIM Low Order - Trace Identifier Mismatch Failure

25363

RAI

RFI - Low Order - Remote Failure/Alarm Indication

25364

UNIDENTIFIED

G811 - Primary Reference Clock Traceable

25365

UNIDENTIFIED

G812 - Transit Node Clock Traceable

25366

UNIDENTIFIED

G812 - Local Node Clock Traceable

25367

UNIDENTIFIED

G813 - Synchronous Equipment Timing Source Traceable

25368

UNIDENTIFIED

E1 Loopback due to FEAC Command

25369

UNIDENTIFIED

E1 Loopback Command Sent to Far End

25370

UNIDENTIFIED

E3 Loopback due to FEAC Command

25371

ENV

Far End Multiple E1 LOS Detected on E3

25372

ENV

Far End E1 Equipment Failure Non-Service Affecting

25373

ENV

Far End E1 Equipment Failure Service Affecting

25374

ENV

Far End Single E1 LOS

25375

ENV

Far End E3 Equipment Failure Service Affecting

25376

UNIDENTIFIED

E3 Loopback Command Sent to Far End

25377

ENV

Far End E3 Equipment Failure Non-Service Affecting

25378

ENV

Low Voltage - Battery A

25379

ENV

High Voltage - Battery A

25380

ENV

Low Voltage - Battery B

25381

ENV

High Voltage - Battery B

25382

UNIDENTIFIED

Procedural Error - MS-SP Ring out of Sync

25383

UNIDENTIFIED

MS-SP Ring Tables Resynchronized

25384

UNIDENTIFIED

Automatic SNCP Switch caused by AIS

25385

UNIDENTIFIED

Automatic SNCP Switch caused by LOP

25386

UNIDENTIFIED

Automatic SNCP Switch caused by UNEQ

25387

UNIDENTIFIED

Automatic SNCP Switch caused by PDI

25388

UNIDENTIFIED

Automatic SNCP Switch caused by SFBER

25389

UNIDENTIFIED

Automatic SNCP Switch caused by SDBER

25390

UNIDENTIFIED

STM Concatenation Error

25391

UNIDENTIFIED

E3 Idle Condition

25392

UNIDENTIFIED

IOS Config Copy Failed

25393

UNIDENTIFIED

IOS Config Copy In Progress

25394

UNIDENTIFIED

Alarms Suppressed by User Command

25399

UNIDENTIFIED

Alarms Suppressed for Maintenance

25400

UNIDENTIFIED

N/A

25401

UNIDENTIFIED

Synchronization Reference Frequency Out of Bounds

25402

UNIDENTIFIED

Ether Tx Excess Flow Ctrl

25403

UNIDENTIFIED

Ether Tx Oversubscribed

25404

UNIDENTIFIED

Transport Layer Failure

25405

UNIDENTIFIED

Ether Rx Excess Flow Ctrl

25406

UNIDENTIFIED

Ether Rx Oversubscribed

25407

UNIDENTIFIED

Ether Tx Underrun

25408

UNIDENTIFIED

SNTP Host Failure

25409

UNIDENTIFIED

DS3 Frame Format Mismatch

25410

UNIDENTIFIED

Alarms/Events Suppressed for this Object

25411

BER_SD

BER Threshold Exceeded for Signal Degrade - High Order

25412

BER_SF

BER Threshold Exceeded for Signal Failure - High Order

25413

BER_SD

BER Threshold Exceeded for Signal Degrade - Low Order

25414

BER_SF

BER Threshold Exceeded for Signal Failure - Low Order

25415

UNIDENTIFIED

Failure to Switch to Protection - High Order Path

25416

UNIDENTIFIED

Failure to Switch to Protection - Low Order Path

25417

UNIDENTIFIED

Wait to Restore

25418

ENV

Extreme High Voltage - Battery A

25419

ENV

Extreme Low Voltage - Battery A

25420

ENV

Extreme High Voltage - Battery B

25421

ENV

Extreme Low Voltage - Battery B

25422

UNIDENTIFIED

Switching Matrix Module Failure

25423

UNIDENTIFIED

Signaling Unable to Set Up Circuit

25424

UNIDENTIFIED

RSVP Hello FSM to Neighbor Down

25425

UNIDENTIFIED

LMP Hello FSM to Control Channel Down

25426

UNIDENTIFIED

LMP Neighbor Discovery Has Failed

25427

UNIDENTIFIED

Unauthorized Incoming Signaling Request

25428

UNIDENTIFIED

Signaled Circuit Going Down

25429

UNIDENTIFIED

Autonomous PM Report Message Inhibited

25430

EQPT

I/O Slot to XCON Communication Failure

25431

UNIDENTIFIED

Forced Switch to Primary Reference

25432

UNIDENTIFIED

Forced Switch to Secondary Reference

25433

UNIDENTIFIED

Forced Switch to Third Reference

25434

UNIDENTIFIED

Forced Switch to Internal Clock

25435

LOM