Cisco Active Network Abstraction Technology Support and Information Model Reference Manual, 3.6.4
Physical Equipment

Table Of Contents

Physical Equipment

Inventory and Information Model Objects (IMOs)

Chassis

Shelf

Module

Power Supply

Port Connector

Service Alarms


Physical Equipment


This chapter describes the level of support that Cisco ANA provides for physical equipment, as follows:

Inventory and Information Model Objects (IMOs)

Service Alarms

Inventory and Information Model Objects (IMOs)

This section includes the following tables:

Chassis (IChassis)

Shelf (IShelf)

Module/Board (IModule)

Power Supply (IPowerSuply)

Port Connector (IPortConnector)

Chassis

The following Chassis object describes a chassis equipment holder, which is bound by its Contained Equipment Holders attribute to other equipment holders such as shelves and slots.

Table 19-1 Chassis (IChassis)

Attribute Name
Attribute Description
Scheme
Polling Interval

Description

Chassis description

Any

Configuration

Equipment Holder Type

Equipment holder type (Chassis)

Any

Configuration

Contained Equipment Holders

Contained equipment holders

Any

Configuration

Contained Equipments

Contained equipment

Any

Configuration


Shelf

The following Shelf object describes a shelf equipment holder, which is bound by its Contained Equipment Holders and Contained Equipments attributes to other equipment holders and equipments objects it contains respectively.

Table 19-2 Shelf (IShelf)

Attribute Name
Attribute Description
Scheme
Polling Interval

Description

Chassis description

Any

Configuration

Status

Shelf status

Any

Configuration

Equipment Holder Type

Equipment holder type (Shelf)

Any

Configuration

Contained Equipment Holders

Contained equipment holders

Any

Configuration

Contained Equipments

Contained equipment

Any

Configuration


Module

The following Module object describes a module/board equipment, which is bound by its Contained Equipment Holders and supported Physical Termination Points attributes to other equipment holders (sub slots) and supported physical Termination Points (Port Connectors) objects it contains respectively.

Table 19-3 Module/Board (IModule)

Attribute Name
Attribute Description
Scheme
Polling Interval

Module Name

Module name

Any

Configuration

Module Description

Module description

Any

Configuration

Software Version

Software version

Any

Configuration

Operational Status

Operational status (Unknown, OK, Warning, Minor, Major, Critical, UnManaged, Enabled, Disabled, Information, Cleaning, Standby)

Any

Configuration

Hardware Type and Version

Hardware type and version

Any

Configuration

Management IP Address

Management IP address

Any

Configuration

Redundant Equipment

Redundant equipment number

Any

Configuration

Configured Redundancy

Configured redundancy (Null, Working, Protecting, None)

Any

Configuration

Redundancy Status

Redundancy status (Null, Active, Standby, None)

Any

Configuration

Operational Status Last Change

Date of last operational status change

Any

Configuration

Contained Equipment Holders

Contained equipment holders

Any

Configuration

Supported Physical Termination Points

Supported physical termination points

Any

Configuration


Power Supply

The following Power Supply object describes a power supply equipment, which is bound by its Contained Equipment Holders attributes to other equipment holders objects that it contains.

Table 19-4 Power Supply (IPowerSuply)

Attribute Name
Attribute Description
Scheme
Polling Interval

Operational Status

Operational status (Unknown, OK, Warning, Minor, Major, Critical, UnManaged, Enabled, Disabled, Information, Cleaning, Standby)

Any

Status

Hardware Type and Version

Hardware type and version

Any

Configuration

Management IP Address

Management IP address

Any

Configuration

Redundant Equipment

Redundant equipment number

Any

Configuration

Configured Redundancy

Configured redundancy (Null, Working, Protecting, None)

Any

Configuration

Redundancy Status

Redundancy status (Null, Active, Standby, None)

Any

Configuration

Operational Status Last Change

Date of last operational status change

Any

Configuration

Contained Equipment Holders

Contained equipment holders

Any

Configuration


Port Connector

The following Port Connector object describes a port connector physical termination point, which is being accessed by the Module containing it.

Table 19-5 Port Connector (IPortConnector)

Attribute Name
Attribute Description
Scheme
Polling Interval

Location

Port connector location

Any

Configuration

Alias

Port alias

Any

Configuration

Type

Port connector type (Unknown, BNC, RJ11, RJ45, Fiber Optic, RJ48, Fiber Optic FC, Fiber Optic SC, Fiber Optic ST, Fiber Optic LC, Internal, Backplane, Fiber Optics MT RJ, DB 15 Pin, SMB, DB 60 Pin, DB 50 Pin, 34-pin Winchester, Generic, DB 9 Pin)

Any

Configuration

Sub Ports

Sub connection termination points (currently being used only for Lucent SONET/ SDH equipment)

Any

Configuration

Supporting Equipment

Supporting equipment in which this port connector resides in

Any

Configuration

Contained Connection Termination Points

Bound Connection Termination Points

Any

Configuration


Service Alarms

The following alarms are supported for this technology:

Card Out/Card In

Card Down/Card Up


Note For a detailed description of these alarms and for information about correlation see the Cisco Active Network Abstraction Fault Management User Guide.