Table Of Contents
Services Messages
CGN Messages
IFLX_LIB_EA Messages
IFLX_LIB_MGR Messages
IPSEC_SVI_EA Messages
IPSEC_SVI_NETIO Messages
OT Messages
PERF_TRAFFIC_ALERT Messages
rspp_drop Messages
RSPP_MA Messages
RSPP_REPO Messages
RSPP_REX Messages
RSPP_RIO_EA Messages
rspp_rio_netio Messages
RSPP_ROXI Messages
SBC_MPF Messages
SBCSVI_BILLING Messages
SBCSVI_EA Messages
SBCSVI_NETIO Messages
SD_COMMON Messages
SD Messages
SESVI_EA Messages
SESVI_NETIO Messages
SRD_AGENT Messages
SRD_LIB Messages
SRD Messages
SVII_EA_GSR Messages
SVII_EA_STATS Messages
SVII_EA Messages
SVII_LRD_SPA Messages
SVII_MGR Messages
VASI_EA Messages
VASI_MA Messages
VASI_NETIO Messages
Services Messages
This section contains all Services related System Error Messages.
CGN Messages
Error Message
%SERVICES-CGN-3-APP_INTF
[chars] intf cant be moved from one cgn instance to
another without first removing it from the latter
Explanation ServiceApp interface cannot be moved from one cgn instance to another without first
removing it from the latter.
Recommended Action This is a serious error and cgn_ma process has to be restarted.
Error Message
%SERVICES-CGN-3-APP_INTF_INCON
Information received for Current inst [chars] and
New inst [chars] for interface [chars] are different
Explanation The received instance info for this interface is same as what had already been
configured.
Recommended Action This is a serious error and cgn_ma process has to be restarted.
Error Message
%SERVICES-CGN-3-APP_INTF_INST
It is fine to have Current inst [chars] and New
inst [chars] for interface [chars] as same
Explanation The received instance info for this interface is same as what had already been
configured.
Recommended Action This is a serious error and cgn_ma process has to be restarted.
Error Message
%SERVICES-CGN-3-CORE_FAIL
Configuration failed to apply for cgn '[chars]'. Use
'show cgn trace master-agent apply reverse' command for failure details.
Explanation some core(s) not responding from the Roddick.
Recommended Action Collect MA and EA traces.
Error Message
%SERVICES-CGN-3-EA_FAIL
[chars]
Explanation EA failed to apply the config.
Recommended Action None.
Error Message
%SERVICES-CGN-3-INITFAIL
[chars]:[dec]:[chars]
Explanation A failure occurred during the initialization of the CGN process on a particular node. The
process will be restarted. Until the process starts successfully, any
Recommended Action Try restarting the CGN process showing this error.
Error Message
%SERVICES-CGN-3-INVALID_IP
[chars] IP address:[chars] is INVALID
Explanation The ip address is invalid.
Recommended Action This is a serious error and the function returns from there.
Error Message
%SERVICES-CGN-3-LWM_FAIL
[chars]: Error code: [dec]. Error msg: [chars]
Explanation An LWM related operation failed.
Recommended Action None.
Error Message
%SERVICES-CGN-3-MSGQ_FAIL
[chars]:[chars]
Explanation Message Q operation failed.
Recommended Action Restart process 'cgn_ma'.
Error Message
%SERVICES-CGN-3-RODDICK_UPD_FAIL
[chars]
Explanation Roddick was not updated with change in vrf db.
Recommended Action This is a serious error and cgn_ma process has to be restarted.
Error Message
%SERVICES-CGN-3-SD_FAIL
[chars]:[chars]
Explanation An SD related operation failed.
Recommended Action This is a serious error and will prevent the system from functioning properly.
Error Message
%SERVICES-CGN-3-STATPORT_MAP
Inside IP: [chars] And Port: [dec] Statically Mapped
To Outside IP:[chars] And Port:[dec]
Explanation The static port mapping requested has succeeded.
Recommended Action This is a success message and used to inform the user about the outside
ipaddress and port number mapped to the inside address and port number.
Error Message
%SERVICES-CGN-3-VRF_DB_UPD_FAIL
[chars]
Explanation The VRF database in cgn-ma was not updated .
Recommended Action This is a serious error and cgn_ma process has to be restarted.
Error Message
%SERVICES-CGN-4-ERR_MEM
[chars]
Explanation CGN modules are failed to allocate memory due to low memory conditions in the
System.
Recommended Action Increase System Memory or stop some applications which are not required.
Error Message
%SERVICES-CGN-7-ERR_SYSDB
[chars]:[chars]
Explanation A sysdb operation failed. See error message text for details of error. This may impact
some functionality of CGN depending upon where the error occurred.
Recommended Action None
IFLX_LIB_EA Messages
Error Message
%SERVICES-IFLX_LIB_EA-3-ADJACENCY
Error setting up adjacencies for an interface:
[chars]
Explanation An error was encountered while trying to set up adjacency information for a InterFlex
interface. The exact error is detailed in the error message. Packets will not be forwarded to the
affected interface.
Recommended Action It may help to restart the affected InterFlex EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be addressed first. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IFLX_LIB_EA-3-INITFAIL
Failure during initialization: [chars]
Explanation A failure occurred during the initialization of the InterFlex EA process on a particular
node. The process will be restarted. Until the process starts successfully, any InterFlex interface
pairs located on that node will not come up. (If there is a standby node the interfaces should come
up on the standby).
Recommended Action *RECUR*
Error Message
%SERVICES-IFLX_LIB_EA-3-SSC_SEND
Error while sending messages to Service
Director: [chars]
Explanation A problem was encountered while trying to send a batch of messages to the Service
Director. The Service Director may not be up to date with the state of services on this node, so
InterFlex interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the InterFlex EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IFLX_LIB_EA-3-SSC_SEND_SRV
Error while sending message about [chars]
to Service Director: [chars]
Explanation A problem was encountered while trying to send a single message to the Service
Director. The Service Director may not be up to date with the state of this services on this node, so
the associated InterFlex interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the InterFlex EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IFLX_LIB_EA-3-STATE_CHANGE
An error occurred while checking the state
for '[chars]': [chars]
Explanation While the InterFlex EA process was checking the state for the specified interface pair,
an error was encountered. The interface pair in question may be left in an inconsistent state.
Recommended Action It may help to restart the InterFlex EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IFLX_LIB_EA-3-UNABLE_TO_RESYNC
The Interflex EA library was unable to
synchronize interfaces
Explanation In order to correct any problems, the Interflex EA will reconnect to IM to prompt a
resync. If this message is displayed then this resync is failing. This may cause configured interfaces
to no longer forward traffic, or interfaces which have been shut down or deleted to continue to do so.
Recommended Action Firstly the processing displaying this message should be restarted. If this fails
to solve the issue, then the configuration should be removed and readded. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
IFLX_LIB_MGR Messages
Error Message
%SERVICES-IFLX_LIB_MGR-3-INIT
Failed to initialize Interflex interface owner
process. Stage: [chars], error: [chars]
Explanation The Interflex Manager failed to startup correctly. Though it will get automatically
restarted, the error is unlikely to be recoverable.
Recommended Action *RECUR*
Error Message
%SERVICES-IFLX_LIB_MGR-3-INTF_CREATE_FAIL
Failed to cleanup after interface
creation failed. Error: [chars]
Explanation The Interflex Manager failed to completely clean up interface state after an interface
creation failed. This will have left the system in an inconsistent state. The most likely reason for this
error is memory exhaustion.
Recommended Action Look for ways to free up memory and restart the interflex_mgr process.
Error Message
%SERVICES-IFLX_LIB_MGR-4-UNABLE_TO_RESYNC
Unable to reconnect to perform a
resync: [chars]
Explanation The Interflex Manager process was unable to reconnect to another process in order to
prompt a resync. Interflex may now be out of sync with the rest of the system until it is restarted.
Recommended Action *RECUR*
Error Message
%SERVICES-IFLX_LIB_MGR-6-NOT_ENOUGH_MAC_ADDRESSES
There were not enough hardware
MAC addresses available to assign to the configured interfaces.
Explanation The Interflex Manager was unable to obtain enough MAC addresses for the configured
Interflex interfaces. The system has a finite number of MAC addresses in the hardware, which are
all currently used.
Recommended Action A MAC address should be manually assigned to any Interflex interfaces which
were unable to obtain one from the hardware.
IPSEC_SVI_EA Messages
Error Message
%SERVICES-IPSEC_SVI_EA-3-INITFAIL
Failure during initialization. Error: [chars]
Explanation A failure occurred during the initialization of the IPSec SVI EA process on a particular
node. The process will be restarted. Until the process starts successfully, any IPSec SVI interfaces
located on that node will not come up. (If there is a standby node the interfaces should come up on
the standby).
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-INTERNAL
[chars]
Explanation An unexpected internal error has occurred in the IPSec SVI EA process. The process
will restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-INTERNAL_ERR
[chars] : [chars]
Explanation An unexpected internal error has occurred in the IPSec SVI EA process. The process
will restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-LINK_FAIL
Error while [chars]ing [unsigned int]
interfaces: [chars]
Explanation An error occurred while attempting to program HW for IPSec SVI on specified node.
The interfaces will not come up. If there is a standby node configured for the interfaces, they may
come up on the standby.
Recommended Action It may help to shut down, then bring up, the IPSEc SVI interfaces in question.
Error Message
%SERVICES-IPSEC_SVI_EA-3-NOT_FOUND
Received request for an interface
(0x[pointer]) that is not in our database
Explanation The IPSec SVI EA process received a request to process an interface that does not exist
in its database. This indicates some sort of internal inconsistency.
Recommended Action It may help to restart the IPSec SVI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-SSC_SEND
Error while sending messages to Service
Director: [chars]
Explanation A problem was encountered while trying to send a batch of messages to the Service
Director. The Service Director may not be up to date with the state of services on this node, so IPSec
SVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the IPSec SVI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-SSC_SEND_SRV
Error while sending message about [chars]
to Service Director: [chars]
Explanation A problem was encountered while trying to send a single message to the Service
Director. The Service Director may not be up to date with the state of this services on this node, so
the associated IPSec SVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the IPSec SVI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_EA-3-STATE_CHANGE
An error occurred while checking the state
for '[chars]': [chars]
Explanation While the IPSec SVI EA process was checking the state for the specified interface, an
error was encountered. The interface in question may be left in an inconsistent state.
Recommended Action It may help to restart the IPSec SVI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
IPSEC_SVI_NETIO Messages
Error Message
%SERVICES-IPSEC_SVI_NETIO-3-INIT_DEBUG
Failure of debug initialization during
[chars]. Error: [chars]
Explanation A failure occurred during the initialization of debug for the NetIO caps. If this occurred
during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-IPSEC_SVI_NETIO-3-INIT_TRACE
Failure initializing tracing ([chars]
buffer). Error: [chars]
Explanation A failure occurred during the initialization of tracing for the NetIO caps. This will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
OT Messages
Error Message
%SERVICES-OT-3-ERROR
[chars]
Explanation Internal error.
Recommended Action 'Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.'
Error Message
%SERVICES-OT-4-WARNING
[chars]
Explanation Internal Warning.
Recommended Action 'Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.'
Error Message
%SERVICES-OT-6-TRACK_INFO
[chars]
Explanation Internal information. for example: track state changes.
Recommended Action 'Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.'
PERF_TRAFFIC_ALERT Messages
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-0-ALM_EMERG
[chars]|[chars]|ID [unsigned
int]|React [unsigned int] [chars]|Src_IP [chars], Src_Port [unsigned int], Dst_IP
[chars], Dst_Port [unsigned int]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-0-GRP_ALM_EMERG
[chars]|[chars]|Class
[chars]|React [unsigned int] [chars]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-1-ALM_ALERT
[chars]|[chars]|ID [unsigned
int]|React [unsigned int] [chars]|Src_IP [chars], Src_Port [unsigned int], Dst_IP
[chars], Dst_Port [unsigned int]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-1-GRP_ALM_ALERT
[chars]|[chars]|Class
[chars]|React [unsigned int] [chars]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-2-ALM_CRIT
[chars]|[chars]|ID [unsigned int]|React
[unsigned int] [chars]|Src_IP [chars], Src_Port [unsigned int], Dst_IP [chars],
Dst_Port [unsigned int]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-2-GRP_ALM_CRIT
[chars]|[chars]|Class [chars]|React
[unsigned int] [chars]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-3-ALM_ERR
[chars]|[chars]|ID [unsigned int]|React
[unsigned int] [chars]|Src_IP [chars], Src_Port [unsigned int], Dst_IP [chars],
Dst_Port [unsigned int]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
Error Message
%SERVICES-PERF_TRAFFIC_ALERT-3-GRP_ALM_ERR
[chars]|[chars]|Class [chars]|React
[unsigned int] [chars]
Explanation The monitored flow has traffic issues as indicated by the react trigger. The problem is
introduced either at some upstream router or even at the traffic source itself. Alternatively, a
configuration mismatch between the traffic source and this router (for the flow data rates etc.) can
cause this error.
Recommended Action Check to see if traffic source is indeed sending traffic. Check that the traffic
characteristics defined at the source match that on the monitoring router. Trace the traffic flow
upstream to the source and verify flow-mon statistics at each applicable hop. Check for packet drops
for the flow at intermediate hops - between source and the monitoring router
rspp_drop Messages
Error Message
%SERVICES-rspp_drop-3-DEBUG
Failed to [chars] debug for service diversion drop
caps: [chars]
Explanation A problem with the debug infrastructure was encountered by the service diversion drop
processing in NetIO. This is not fatal, and simply means that the 'debug services diversion drop'
commands may be unavailable. All non-verbose messages are still traced in a circular buffer, and
the most recent of these can be inspected with the 'show services diversion drop trace' commands.
Recommended Action *RECUR*
Error Message
%SERVICES-rspp_drop-3-DIVERT
Unable to [chars] packet (can't [chars])[chars]%s
Explanation A pre-routed packet created on the router's host stack hit a problem during service
diversion processing. The packet was dropped.
Recommended Action *SUPPORT*
Error Message
%SERVICES-rspp_drop-3-INIT
Failed to [chars] when initializing service diversion
drop caps (id [dec]): [chars]
Explanation A failure occurred when installing the capability in NetIO to process slow path packets
for service diversion. If this occurred during an upgrade operation then it will cause the NetIO
process to reload. Otherwise this will cause the capsulation to be unloaded, and an error will be
returned to the user.
Recommended Action *RECUR*
Error Message
%SERVICES-rspp_drop-3-UNDIVERT
Unable to undivert packet (can't [chars]):
[chars]
Explanation A packet could not be sent out to its original destination after firewalling. The packet
was dropped.
Recommended Action *SUPPORT*
RSPP_MA Messages
Error Message
%SERVICES-RSPP_MA-2-IMP_FAILED
An error was detected whilst performing [chars]
for [chars] (Error: [chars]). Traffic Diversion may now be inconsistent.
Explanation Some aspect of diversion implementation has failed. This means that traffic may be
inconsistently diverted for the specified interface (i.e. traffic may be diverted to the service card in
the ingress direction, but not on egress). Note that, where the error message indicates a single
interface that is affected, there may also be other attachments impacted by the error.
Recommended Action Restarting the rspp_ma process on the node which produced the error may
solve the issue. If not, contact support.
Error Message
%SERVICES-RSPP_MA-3-EVENT
Error receiving event: [chars]
Explanation An error occurred receiving an event from the OS. The process will restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-3-IMP_ERROR
A persistent error has occurred during the
implementation of one or more attachments. Diversion may be in an inconsistent
state
Explanation Whilst attempting to implement one or more attachments, the service diversion
infrastructure has hit one or more problems that were not solved by a retry, and as such one or more
diversions may be in an inconsistent state. Retries will continue to be made, and a further message
will be printed if this situation clears.
Recommended Action Running 'show firewall attachments' will provide information on which
attachments are suffering from errors, and in which way they will not be operating correctly. These
problems may be cleared by removing and re-attaching the service to the specified interface. If this
does not resolve the problem, then support should be contacted.
Error Message
%SERVICES-RSPP_MA-3-INIT
Failure during initialization of RSPP MA [chars]. Error:
[chars]
Explanation A failure occurred during the initialization of the RSPP MA, the process responsible for
managing the diversion of packets to services such as firewalls. The initialization will be aborted
and retried.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-3-INIT_NON_FATAL
Non-fatal error during initialization of RSPP
MA [chars]: [chars] Continuing with initialization.
Explanation A non-fatal failure occurred during the initialization of the specified module of RSPP
MA, the process responsible for managing the diversion of packets to services such as firewalls. This
will typically mean that some level of debugging support will not be provided for the process (e.g.
error codes will not be decoded), but the functioning of the process is not otherwise affected.
Restarting the process should restore full debugging support.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-3-LCFG_DELETE
Failed to process local configuration delete for
interface [chars]. Error: [chars]
Explanation An error has occurred while removing the diversion implemented for the given
interface. The error string will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, adding and removing a service attachment for the
interface indicated in the message may remove the error. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information. If the error is a resource
error this will be indicated in the error description given. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration. If any
inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may
solve the problem.
Error Message
%SERVICES-RSPP_MA-3-LCFG_UPDATE
Failed to process local configuration update for
attachment of service [chars] of type [chars] to interface [chars] with attachment
ID [chars]. Error: [chars]
Explanation An error has occurred while implementing the diversion required for the given service
attachment. The error string will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-3-NO_VFW
RSPP MA was started when the firewalls package was not
installed. Exiting
Explanation RSPP MA, the service diversion management agent, could not complete initialization
as the firewall service package could not be found in the current installed image. Restart will not be
attempted.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-RSPP_MA-3-PUBLISH_DELETE
Failed to publish local configuration delete
for interface [chars]. Error: [chars]
Explanation An error has occurred while indicating the deletion of the given service attachment
removal to nodes other than that local to the interface indicated. Packet diversion may now be
inconsistent. The error string will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, adding and removing a service attachment for the
interface indicated in the message may remove the error. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information. If the error is a resource
error this will be indicated in the error description given. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration. If any
inconsistency in packet forwarding to the indicated interfaces is seen, a restart of RSPP MA may
solve the problem.
Error Message
%SERVICES-RSPP_MA-3-PUBLISH_UPDATE
Failed to publish local configuration update
for attachment of service [chars] of type [chars] to interface [chars] with
attachment ID [chars] to remote nodes. Error: [chars]
Explanation An error has occurred while indicating the occurrence of the given update to nodes other
than that local to the interface indicated. Packet diversion may now be inconsistent. The error string
will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-3-RCFG
Failed to process remote config notification of [chars]
of attachment of service [chars] of type [chars] to interface [chars] with
attachment ID [chars]. Error: [chars]
Explanation An error has occurred while processing the attachment of a service to an interface
remote to this node. Packet diversion may now be inconsistent on this node. The error string will
give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-3-RCFG_REFRESH
Error deleting any stale attachment
publications to remote nodes. Error: [chars]
Explanation If a virtual firewall or other service is attached to an interface, then all cards in the
system need to know. Similarly, if a service attachment is deconfigured, then all cards needs to be
notified. This will not happen if the interface's line card is down (e.g. a preconfigured attachment is
removed while the card is absent from the chassis and then re-inserted). A backup mechanism exists
for this case, that ensures that any attachments that were deconfigured in such a situation really are
removed globally. This error indicates that a problem occurred with this backup mechanism. So if a
service attachment was deconfigured while the card was down, the rest of the system might not have
caught up, and could still be diverting or dropping traffic for that interface.
Recommended Action If an interface seems 'stuck', then configuring an attachment again, committing
the configuration, and then de-configuring that attachment and committing should un-stick it.
Error Message
%SERVICES-RSPP_MA-4-DUP_CREATE
Attachment of service [chars] of type [chars] to
interface [chars] with attachment ID [chars] invalid due to duplicate attachment
to interface [chars]. Both attachments will be invalidated.
Explanation The same service attachment has been configured on two or more interfaces, resulting
in both attachments being viewed as failed and moved in to failure state.
Recommended Action Removing the given configuration until zero or one instances of the attachment
exist will resolve this misconfiguration.
Error Message
%SERVICES-RSPP_MA-4-DUP_CREATE_ERR
Error withdrawing attachment of service
[chars] of type [chars] to interface [chars] with attachment ID [chars] (invalid
due to duplicate attachment to interface [chars]): [chars]
Explanation An error has occurred processing an invalid configuration whereby the same service
attachment has been configured on two or more interfaces (which should result in both attachments
being viewed as failed and moved in to failure state). Packet diversion may now be inconsistent. The
error string will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, removing the initial misconfiguration may remove
this error. If the error is a resource error this will be indicated in the error description given. Reduce
other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory
configuration. If any inconsistency in packet forwarding to the indicated interfaces is seen, a restart
of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-4-DUP_REMOVE
Attachment of service [chars] of type [chars] to
interface [chars] with attachment ID [chars] now valid due to removal of duplicate
attachment to interface [chars]. Attachment will be reimplemented.
Explanation The given attachment configuration, which was previously invalid due to duplicate
attachments being configured on different interfaces, is now valid as the duplicate attachment
configuration has been removed.
Recommended Action No action is required.
Error Message
%SERVICES-RSPP_MA-4-DUP_REMOVE_ERR
Error reinstalling attachment of service
[chars] of type [chars] to interface [chars] with attachment ID [chars] (now valid
due to removal of duplicate attachment to interface [chars]): [chars]
Explanation The given attachment configuration, which was previously invalid due to duplicate
attachments being configured on different interfaces, is now valid as the duplicate attachment
configuration has been removed, but an error has occurred reimplementing the attachment. The error
string given should give more details on the error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-4-FA_BATCH_ERR
Errors occurred processing batch of failure
action notifications. Total Errors: [unsigned int], First Error [chars]
Explanation One or more errors occurred in RSPP MA, the service diversion management agent,
during the processing of a set of configuration detailing the failure policies to be applied in the event
of service failure. The configured failure policies may now not be implemented on the node
indicated. The error string will give more detail on the type of error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-4-RCFG_BATCH
Failed to signal [chars] of batch of remote config
publications. Error: [chars]
Explanation An error has occurred sending information on service attachments to interfaces local to
the node to remote nodes.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-4-RED_STATE_ERR
Error handling change in redundancy state.
Error [chars]
Explanation An error has occurred during the handling of a notification from Sysmgr indicating a
change in the redundancy state of the card indicated (e.g. from standby to online).
Recommended Action Restarting RSPP MA may solve the problem. If the message recurs, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-4-RED_STATE_UNK
Unable to handle redundancy state
notification. New redundancy state [unsigned int], previous state [unsigned int]
Explanation A notification has been received from Sysmgr indicating that the redundancy state (e.g.
active, standby, etc.) of the card has changed to a state unknown to RSPP MA. RSPP MA will
continue to use the old state.
Recommended Action A restart of RSPP MA may solve the problem. If the message recurs, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-4-RESYNC_FAILED
Failed to resync diversions correctly. Error:
[chars]
Explanation An error has occurred following a restart of RSPP MA in the reconciliation of persistent
data structures with the current configuration. Packet diversion may now be inconsistent.
Recommended Action Restarting RSPP MA may clear the error. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_MA-4-SD_BATCH_ERR
Errors occurred processing batch of Service
Director notifications. Total Errors: [unsigned int], First Error [chars]
Explanation One or more errors occurred in RSPP MA, the service diversion management agent,
during the processing of a set of notifications from Service Director, containing service locations
and diversion information. Diversions for service attachments may now be inconsistent on the given
node. The error string will give more detail on the type of error that has occurred.
Recommended Action If the error is a resource error this will be indicated in the error description
given. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a
larger memory configuration. If any inconsistency in packet forwarding to the indicated interfaces
is seen, a restart of RSPP MA may solve the problem. If the error string given does not indicate that
this is a resource error, copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-RSPP_MA-4-SD_ERR
Error requesting service information from the Service
Director on services referenced by the last batch of attachment or failure action
configuration. Error [chars]
Explanation When a service attachment (e.g. a firewall attachment) is configured on an interface, the
local RSPP MA process (the service diversion management agent) must request information on the
attached service from Service Director to be able to implement the required diversion. This error
indicates that a problem has arisen in this request. The error string given should give more details
on the error that has occurred.
Recommended Action For non-resource errors, removing and adding back the configuration that
prompted the message may remove the error. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information. If the error is a resource error this will
be indicated in the error description given. Reduce other system activity to ease memory demands.
If conditions warrant, upgrade to a larger memory configuration. If any inconsistency in packet
forwarding to the indicated interfaces is seen, a restart of RSPP MA may solve the problem.
Error Message
%SERVICES-RSPP_MA-6-IMP_ERROR_CLEARED
All pre-existing persistent errors have
been cleared. All diversion should now be operating correctly.
Explanation This message should only be seen after a corresponding IMP_ERROR message has been
seen. It indicates that any problems with diversions should now have been resolved.
Recommended Action No further action should be necessary.
Error Message
%SERVICES-RSPP_MA-6-PROBLEM_EXITING
Problem ensuring an orderly exit: [chars]
Explanation The process implementing service diversions (e.g. for virtual firewalls) has just exited,
since the last service attachments have just been deconfigured. As part of this orderly shutdown, the
process tried to inform System Manager that this was happening, but hit a problem in signalling this
fact. The system should have recovered from this problem fully; however, very rarely it is possible
that some other service attachment configuration in the same commit could be rejected.
Recommended Action If any service attachments in the same configuration commit were rejected,
simply re-commit them.
RSPP_REPO Messages
Error Message
%SERVICES-RSPP_REPO-3-DUAL_ERR
Error encountered by REPO whilst processing a dual
adjacency update request for the adjacency for interface handle [hex]: [chars]
Explanation An error has occurred in the FIB library responsible for implementing diversions (e.g.
for virtual firewall attachments) on a service card, following a call by FIB to retrieve the post-egress
diversion forwarding information. If the interface given has a service attached then forwarding
following egress diversion to this service may now be incorrect as a result of this error.
Recommended Action Restarting the fib_mgr process on the node which produced the error may solve
the issue. If not, contact support.
Error Message
%SERVICES-RSPP_REPO-3-INIT
Error initializing REPO: [chars]
Explanation An error has occurred during the initialization of the FIB library responsible for
implementing diversions (e.g. for virtual firewall attachments). Service attachments may now fail to
be implemented properly as a result of this error.
Recommended Action Restarting the fib_mgr process on the node which produced the error may solve
the issue. If not, contact support.
Error Message
%SERVICES-RSPP_REPO-3-INIT_MSG
Error encountered by REPO whilst processing the
initialization message from RSPP MA: [chars]
Explanation An error has occurred in the IPC between the Management Agent for service diversions
(e.g. for virtual firewall attachments) and the FIB Library responsible for implementing them, in the
initialization stage. The initialization will be aborted, and no changes to service attachment
configuration will be made in the forwarding plane
Recommended Action Restarting the fib_mgr process on the node which produced the error may solve
the issue. If not, contact support.
Error Message
%SERVICES-RSPP_REPO-3-TWEAK_ERR
Error encountered by REPO whilst processing an
adjacency update request for the adjacency for interface handle [hex]: [chars]
Explanation An error has occurred in the FIB library responsible for implementing diversions (e.g.
for virtual firewall attachments) following a request from FIB to check whether a diversion should
be in place for the given adjacency. The adjacency given may now be incorrect as a result of this
error.
Recommended Action Restarting the fib_mgr process on the node which produced the error may solve
the issue. If not, contact support.
Error Message
%SERVICES-RSPP_REPO-3-UPDATE_MSG
Error encountered by REPO whilst processing the
diversion update message ([hex]) from RSPP MA: [chars]
Explanation An error has occurred in the IPC between the Management Agent for service diversions
(e.g. for virtual firewall attachments) and the FIB Library responsible for implementing them,
during a diversion update. The update will not be implemented.
Recommended Action Restarting the fib_mgr process on the node which produced the error may solve
the issue. If not, contact support.
RSPP_REX Messages
Error Message
%SERVICES-RSPP_REX-3-EDM
Failed to initialize diversion manager external data
manager, error: [chars]. Diagnostic show commands may not function correctly,
other functionality is unaffected.
Explanation During initialization of the EDM an error occurred. The EDM was not successfully
registered, so show commands and other manageability applications may not function correctly.
Otherwise the diversion manager will work correctly.
Recommended Action This is not a fatal error. If the show commands are required, restarting the REX
process should clear up the problem.
Error Message
%SERVICES-RSPP_REX-3-IMP_CONNECT
Failed to connect to IM Proxy. Error: [chars]
Explanation The diversion manager was unable to connect to IM Proxy to register as an interface
capsulation. Diversion information may not be correctly applied or inconsistent.
Recommended Action The connection will be retried automatically. If the message recurs, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_REX-3-INIT
Failure [chars] during initialization of diversion
execution agent. Error: [chars]
Explanation A failure occurred during the initialization of the RSPP REX library. This is used to
divert packets, e.g. to a virtual firewall.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_REX-3-MEM
Diversion manager failed to get memory [chars].
Diversions (e.g. to a virtual firewall) may not have been correctly applied.
Explanation During processing of a new or updated diversion, insufficient memory was available.
The diversion information was not applied, and future updates may also not be applied correctly.
Recommended Action This indicates a low memory condition. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration. Once the
memory condition is resolved, execute the command 'proc restart rspp_rex' for the node where the
error message originated to ensure all diversion information is correctly set up.
Error Message
%SERVICES-RSPP_REX-3-MSG_REPLY
Unable to send a reply to diversion manager's
client. Error: [chars]
Explanation The diversion manager process was unable to send a reply to a message sent to one of
its clients. Diversion information may be inconsistent.
Recommended Action Restarting the rspp_rex and fwc processes should clear the problem. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-RSPP_REX-3-SYSDB
Diversion manager failed to communicate with SysDB.
Error: [chars]
Explanation The diversion manager was unable to communicate with SysDB. Notifications may be
missed, and manageability functionality may not be available.
Recommended Action Check the status of SysDB, and restart the SysDB and firewall controller
processes.
Error Message
%SERVICES-RSPP_REX-6-CORE
The diversion manager has reached an unexpected
situation ([chars] dumping core - this is NOT a crash.
Explanation An unexpected situation was reached; the diversion manager has voluntarily produced
a core dump for debugging purposes. This does not affect the operation of the diversion manager.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
RSPP_RIO_EA Messages
Error Message
%SERVICES-RSPP_RIO_EA-3-DEBUG
Failed to initialize service ingress diversion
debug facility: [chars]
Explanation An error occurred during initialization of the service ingress diversion debug facility.
The 'debug services diversion rio ea' command will not function correctly. Otherwise service
ingress diversion will work correctly. Executing the command 'proc restart rspp_rio_ea' for the
node where the error message originated might resolve this condition.
Recommended Action This is not a fatal error.
Error Message
%SERVICES-RSPP_RIO_EA-3-DM_REMOVE
Failed to remove service ingress diversion
(ifh equals [hex]). Could not remove [chars]: [chars]
Explanation An error occurred during service ingress diversion removal from the specified interface.
Recommended Action *SUPPORT*
Error Message
%SERVICES-RSPP_RIO_EA-3-EDM
Failed to initialize service ingress diversion
External Data Manager: [chars]
Explanation During initialization of the EDM an error occurred. The EDM was not successfully
registered, so show commands and other manageability applications may not function correctly.
Otherwise service ingress diversion will work correctly. Executing the command 'proc restart
rspp_rio_ea' for the node where the error message originated might resolve this condition.
Recommended Action This is not a fatal error.
Error Message
%SERVICES-RSPP_RIO_EA-3-EVENT_BLOCK
An error was received during event_block:
[chars]
Explanation The service ingress diversion process received an error while waiting for events from
other processes in the system. The process will be restarted.
Recommended Action *RECUR*
Error Message
%SERVICES-RSPP_RIO_EA-3-EVM_CREATE_FAILED
RSPP RIO event manager create failed:
[chars].
Explanation An error occurred during initialization of service ingress diversion process. The process
could not create an event queue used to communicate with other processes in the system. The
initialization will be aborted and retried.
Recommended Action This condition might indicate a low memory condition. Reduce other system
activity to ease memory demand. If the message recurs, copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_RIO_EA-3-FM_INIT_REPLAY
Could not re-synchronize with feature
manager process: [chars]
Explanation During the initialization of ingress diversion process, feature manager process
requested a replay of all current diversions but the replay operation failed.
Recommended Action If this message is reported more than once, execute the command 'proc restart
feat_mgr' for the node where the error message originated.
Error Message
%SERVICES-RSPP_RIO_EA-3-IMP_INIT_ERR
IMP initialization failed during [chars]:
[chars]
Explanation The service ingress diversion process failed while trying to connect to Interface
Manager Proxy process. The process will be restarted. If error still exists, execute the command
'proc restart imp' for the node where the error message originated.
Recommended Action *RECUR*
Error Message
%SERVICES-RSPP_RIO_EA-3-INIT_FAILED
Ingress Diversion process initialization
failed following [unsigned int] function call(s): [chars].
Explanation An error occurred during the initialization of service ingress diversion process. The
initialization will be aborted and retried. Current and future service to an interface will fail until
successful process initialization.
Recommended Action *RECUR*
Error Message
%SERVICES-RSPP_RIO_EA-3-MEM
During ingress diversion installation or update,
failed to get memory for [chars]
Explanation During processing of a new or existing service ingress diversion, insufficient memory
was available. The diversion information was not applied, and future updates may also not be
applied correctly.
Recommended Action This indicates a low memory condition. *REDUCE* Once the memory
condition is resolved, execute the command 'proc restart rspp_rio_ea' for the node where the error
message originated to ensure all diversion information is correctly set up. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_RIO_EA-3-TRACE
Failed to initialize service ingress diversion
trace facility: [chars]
Explanation An error occurred during initialization of the trace facility. There will be no trace
messages for service ingress diversion. The 'show services diversion rio ea trace' command on this
node will not function correctly. Otherwise service ingress diversion will work correctly. Executing
the command 'proc restart rspp_rio_ea' for the node where the error message originated might
resolve this condition.
Recommended Action This is not a fatal error.
Error Message
%SERVICES-RSPP_RIO_EA-6-CORE
The service ingress diversion process has reached
an unexpected situation ([chars] dumping core - this is NOT a crash.
Explanation An unexpected situation was reached; the service ingress diversion process has
voluntarily produced a core dump for debugging purposes. Unless other symptoms are seen than it
can be assumed that the system has recovered.
Recommended Action *SUPPORT*
rspp_rio_netio Messages
Error Message
%SERVICES-rspp_rio_netio-3-CAPS_BUILDER_FAILED
The capsulation build function
failed because '[chars]' (ifh equals [hex]). Error: [chars]
Explanation The service ingress diversion NetIO DLL capsulation builder function failed. Service
ingress diversion in NetIO for the specified interface will not function properly.
Recommended Action *SUPPORT*
Error Message
%SERVICES-rspp_rio_netio-3-CAPS_CONTROL_FAILED
The capsulation control function
failed because '[chars]' (ifh equals [hex]). Error: [chars]
Explanation The service ingress diversion NetIO DLL capsulation function failed. Service ingress
diversion in NetIO for the specified interface will not function properly.
Recommended Action *SUPPORT*
Error Message
%SERVICES-rspp_rio_netio-3-CAPS_UNBUILDER_FAILED
The capsulation unbuild
function failed because '[chars]' (ifh equals [hex]). Error: [chars]
Explanation The service ingress diversion NetIO DLL capsulation unbuilder function failed. Service
ingress diversion in NetIO for the specified interface will not be removed from NetIO process.
Recommended Action *SUPPORT*
Error Message
%SERVICES-rspp_rio_netio-3-INIT_DEBUG
Service ingress diversion NetIO DLL failed
to initialize the debug facility during [chars]: [chars]
Explanation A failure occurred during the initialization of debug for the service ingress diversion
NetIO DLL. If this occurred during an upgrade operation then it will cause the NetIO process to
reload. Otherwise this will cause the capsulation to be unloaded, and an error will be returned to the
user.
Recommended Action *RECUR*
Error Message
%SERVICES-rspp_rio_netio-3-INIT_TRACE
Failed to initialize service ingress
diversion [chars] trace facility within NetIO process: [chars]
Explanation An error occurred during initialization of the trace facility. There will be no NetIO trace
messages for service ingress diversion. The 'show services diversion rio netio trace' command on
this node will not function correctly. Otherwise service ingress diversion will work correctly.
Recommended Action This is not a fatal error.
Error Message
%SERVICES-rspp_rio_netio-3-SUBBLOCK_REG_FAILED
Service ingress diversion NetIO
DLL failed to register the RIO subblock: [chars]
Explanation The service ingress diversion NetIO DLL initialization function failed to register the
RIO subblock type.
Recommended Action *SUPPORT*
Error Message
%SERVICES-rspp_rio_netio-3-TERM_FAILED
Service ingress diversion NetIO DLL
termination failed because '[chars]'. Error: [chars]
Explanation The service ingress diversion NetIO DLL termination function failed.
Recommended Action *SUPPORT*
RSPP_ROXI Messages
Error Message
%SERVICES-RSPP_ROXI-3-IMP_CONNECT
Failed to connect to IM Proxy. Error: [chars]
Explanation The replicated interface owner was unable to connect to IM Proxy to register as an
interface owner. Diversion information may not be correctly applied or inconsistent.
Recommended Action The connection will be retried automatically. If the message recurs, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-RSPP_ROXI-3-INIT
Failure [chars] during initialization of replicated
interface owner. Error: [chars]
Explanation A failure occurred during the initialization of the replicated interface owner process.
This means that attaching services (e.g. a firewall) on the card producing this error to interfaces may
not work.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-RSPP_ROXI-3-MEM
Replicated interface owner failed to get memory [chars]
during diversion update processing. Diversions (e.g. to a virtual firewall) may
not have been correctly applied, and future diversion may also not be correctly
applied.
Explanation During processing of a new or updated diversion, insufficient memory was available.
The diversion information was not applied, and future updates may also not be applied correctly.
Recommended Action This indicates a low memory condition. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration. Once the
memory condition is resolved, execute the command 'proc restart rspp_roxi' for the node where the
error message originated to ensure all diversion information is correctly set up.
Error Message
%SERVICES-RSPP_ROXI-3-REPLICATE
Bulked operation to [chars] [unsigned int]
replicated interface(s) (including [hex]) failed with error: [chars]. Packet
diversion may now be incorrectly set up.
Explanation During the processing of interface create or delete notifications an error occurred that
means the interfaces may not have been replicated or unreplicated correctly. This might result in the
packets that are diverted to the node being dropped. A user with cisco-support privileges may find
the interface name corresponding to the given interface handle using 'show im chains ifhandle
ifhandle'
Recommended Action Restart the rspp_roxi process on the affected node; If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
SBC_MPF Messages
Error Message
%SERVICES-SBC_MPF-6-INFO
MPF_INFO: [chars]
Explanation The system is in normal state. This is info log.
Recommended Action none
SBCSVI_BILLING Messages
Error Message
%SERVICES-SBCSVI_BILLING-3-CONFERR
[chars]
SBC billing paths will not be available
Explanation Couldn't not establish the SBC instance name from SysDB. SBC instance name is
required for the billing cach paths SBC billing application will not be able to save billing records.
Recommended Action Delete the SBC instance and create it again to mount the SBC billing drives.
Error Message
%SERVICES-SBCSVI_BILLING-3-PATHERR
Error: SBC billing cache location [chars]
[chars]: [chars]. Make sure that SBC billing drive is installed and formatted.
SBC billing paths will not be available
Explanation A failure occurred during the creation of an sbc billing cache path. SBC billing
application will not be able to save billing records
Recommended Action Make sure that the drive needed for the type of SBC billing you need (local or
remote) is mounted and formatted. Delete the SBC instance and create again to mount the SBC
billing drives.
Error Message
%SERVICES-SBCSVI_BILLING-4-PATHWARN
SBC billing path [chars] [chars] [chars]
Explanation The SBC billing cache path might require some user action to save the billing records
in an SBC-instance-specific directory. SBC billing will still work properly but the billing records
could either be saved in an SBC-shared directory if the SBC instance name is too long or not saved
at all if there is no space left in the drive.
Recommended Action Make sure that the condition reported doesn't affect the billing records
otherwise, correct the condition by changing the SBC instance name or by manually removing the
billing files depending on the condition reported.
Error Message
%SERVICES-SBCSVI_BILLING-5-PATHSTATUS
SBC billing path [chars] [chars] [chars]
Explanation The SBC billing cache path mount point status has changed and is being reported to the
user for an easier access to the SBC billing records.
Recommended Action Take note of the paths used by SBC billing to access the SBC billing records
SBCSVI_EA Messages
Error Message
%SERVICES-SBCSVI_EA-3-INITFAIL
Failure during initialization. Error: [chars]
Explanation A failure occurred during the initialization of the SBCSVI EA process on a particular
node. The process will be restarted. Until the process starts successfully, any SBCSVI interface
located on that node will not come up. (If there is a standby node the interfaces should come up on
the standby).
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-INTERNAL
[chars]
Explanation An unexpected internal error has occurred in the SBCSVI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-INTERNAL_ERR
[chars] : [chars]
Explanation An unexpected internal error has occurred in the SBCSVI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-LINK_FAIL
Error while [chars]ing [unsigned int]
interfaces: [chars]
Explanation An error occurred while attempting to join together the two halves of some SBCSVI
pairs on the specified node. The pairs will not come up. If there is a standby node configured for the
pairs, they may come up on the standby.
Recommended Action It may help to shut down, then bring up, the SBCSVI interface pairs in
question.
Error Message
%SERVICES-SBCSVI_EA-3-NOT_FOUND
Received request for an interface (0x[pointer])
that is not in our database
Explanation The SBCSVI EA process received a request to process an interface that does not exist
in its database. This indicates some sort of internal inconsistency.
Recommended Action It may help to restart the SBCSVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-SSC_SEND
Error while sending messages to Service Director:
[chars]
Explanation A problem was encountered while trying to send a batch of messages to the Service
Director. The Service Director may not be up to date with the state of services on this node, so
SBCSVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the SBCSVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-SSC_SEND_SRV
Error while sending message about [chars] to
Service Director: [chars]
Explanation A problem was encountered while trying to send a single message to the Service
Director. The Service Director may not be up to date with the state of this services on this node, so
the associated SBCSVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the SBCSVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SBCSVI_EA-3-STATE_CHANGE
An error occurred while checking the state for
'[chars]': [chars]
Explanation While the SBCSVI EA process was checking the state for the specified interface pair,
an error was encountered. The interface pair in question may be left in an inconsistent state.
Recommended Action It may help to restart the SBCSVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
SBCSVI_NETIO Messages
Error Message
%SERVICES-SBCSVI_NETIO-3-INIT_DEBUG
Failure of debug initialization during
[chars]. Error: [chars]
Explanation A failure occurred during the initialization of debug for the NetIO caps. If this occurred
during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SBCSVI_NETIO-3-INIT_TRACE
Failure initializing tracing ([chars]
buffer). Error: [chars]
Explanation A failure occurred during the initialization of tracing for the NetIO caps. This will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
SD_COMMON Messages
Error Message
%SERVICES-SD_COMMON-3-SEND_FAILED
Failed to send a '[chars]' message: '[chars]'
Explanation A required control message could not be sent. The reason for the failure is detailed in
the message. The failure is unexpected, and likely caused by a failure in the underlying transport.
Services controlled by this process are likely to be out of sync as a result.
Recommended Action Restart the 'service_director' process to force a resync of all data, which will
recover the lost message. If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
SD Messages
Error Message
%SERVICES-SD-3-ASSERT
ASSERT failure: [chars]
Explanation The process is in an inconsistent state. The process will exit and restart. All data will be
resynchronized after the restart.
Recommended Action No action is required to recover the system, this will happen automatically.
Report this issue to your Cisco technical support representative and provide the representative with
the gathered information.
Error Message
%SERVICES-SD-3-INIT_FAILED
Initialisation failed, module: [chars], operation:
[chars], error: [chars]
Explanation The Service Director has failed to start up. The operation being attempted is detailed in
the error message. The Service Director will be restarted automatically.
Recommended Action If the error indicates an Out Of Memory error, then attempt to increase the
available resources. Otherwise, if the error persists, contact your technical support representative
copying the error message exactly as it appears.
Error Message
%SERVICES-SD-3-LOOP_FAILED
Unexpected error in event loop: [chars]
Explanation An unexpected error has been encountered in the main Service Director event loop. The
Service Director will be automatically restarted, and should recover by itself.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SD-3-NOMEM
Insufficient resources: [chars]
Explanation There are insufficient resources to perform some action. The error message contains
more details about what action failed. In any case, services may not be operating correctly, and states
may be out of sync.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration. Once the memory conditions have been improved, restart
the Service Director process to allow it to resynchronized with its clients.
Error Message
%SERVICES-SD-3-SYSMGR_FAIL
SysMgr didn't respond when told we're exiting: [chars]
Explanation The Service Director attempted to notify SysMgr that it was exiting and SysMgr
returned an error. If this coincides with an attempt to configure the locations of a service, then
further error may be observed from SysDB.
Recommended Action Restart the Service Director process. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SD-4-INVALID_FIND_SERVICE
An invalid Service Find request was received
(type [hex])
Explanation The Service Director received a batch with an invalid service type field. This can be due
to message corruption, or due to a timing issue but is most likely due to an error in a service process.
Except in the latter case (when it will most probably be repeated) this error is not fatal.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SD-4-WRONG_SSC
Invalid SSC is sending updates on node [hex]. Beginning
recovery
Explanation A Service Controller process not currently registered is sending updates from a node.
The Service Director will now attempt to recover from this by resynchronizing with its clients.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SD-6-RESTART_SELF
The Service Director process requires a restart in
order to synchronize data. This message is informational and requires no further
action. The reason for restart is: [chars]
Explanation The Service Director encountered an error when trying to send a control message, which
could leave the system in an inconsistent state. The error results from an unexpected failure in the
transport infrastructure. The process is now restarting and will then be able to resynchronize its
state, restoring system consistency. This message is for informational purposes only, and no further
action is required as a result. On completion of the resyncronization, the system will have
self-healed, unless any further errors are encountered.
Recommended Action No action is required unless further errors are observed. If further errors are
encountered, wait until possible root problems (such as node reload, or low memory conditions)
have been resolved, and restart the Service Director. If the message recurs, copy the error message
exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
SESVI_EA Messages
Error Message
%SERVICES-SESVI_EA-3-INITFAIL
Failure during initialization. Error: [chars]
Explanation A failure occurred during the initialization of the SESVI EA process on a particular
node. The process will be restarted. Until the process starts successfully, any SESVI interface
located on that node will not come up. (If there is a standby node the interfaces should come up on
the standby).
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-INTERNAL
[chars]
Explanation An unexpected internal error has occurred in the SESVI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-INTERNAL_ERR
[chars] : [chars]
Explanation An unexpected internal error has occurred in the SESVI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-LINK_FAIL
Error while [chars]ing [unsigned int] interfaces:
[chars]
Explanation An error occurred while attempting to join together the two halves of some SESVI pairs
on the specified node. The pairs will not come up. If there is a standby node configured for the pairs,
they may come up on the standby.
Recommended Action It may help to shut down, then bring up, the SESVI interface pairs in question.
Error Message
%SERVICES-SESVI_EA-3-NOT_FOUND
Received request for an interface (0x[pointer])
that is not in our database
Explanation The SESVI EA process received a request to process an interface that does not exist in
its database. This indicates some sort of internal inconsistency.
Recommended Action It may help to restart the SESVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-SSC_SEND
Error while sending messages to Service Director:
[chars]
Explanation A problem was encountered while trying to send a batch of messages to the Service
Director. The Service Director may not be up to date with the state of services on this node, so
SESVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the SESVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-SSC_SEND_SRV
Error while sending message about [chars] to
Service Director: [chars]
Explanation A problem was encountered while trying to send a single message to the Service
Director. The Service Director may not be up to date with the state of this services on this node, so
the associated SESVI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the SESVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-SESVI_EA-3-STATE_CHANGE
An error occurred while checking the state for
'[chars]': [chars]
Explanation While the SESVI EA process was checking the state for the specified interface pair, an
error was encountered. The interface pair in question may be left in an inconsistent state.
Recommended Action It may help to restart the SESVI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
SESVI_NETIO Messages
Error Message
%SERVICES-SESVI_NETIO-3-INIT_DEBUG
Failure of debug initialization during
[chars]. Error: [chars]
Explanation A failure occurred during the initialization of debug for the NetIO caps. If this occurred
during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SESVI_NETIO-3-INIT_TRACE
Failure initializing tracing ([chars]
buffer). Error: [chars]
Explanation A failure occurred during the initialization of tracing for the NetIO caps. This will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
SRD_AGENT Messages
Error Message
%SERVICES-SRD_AGENT-6-NODE_REBOOTING
A change in role requires Node [chars] to
go down for reboot.
Explanation The Service Role Agent has determined a role change requires a reboot of the specified
node. This is not an error.
Recommended Action None. This is expected behavior when changing the role of a card.
SRD_LIB Messages
Error Message
%SERVICES-SRD_LIB-4-NOTIFICATION_FAILED
SRD Library notification failure:
[chars]
Explanation The Service Role Daemon client library received a notification, but was unable to
perform the necessary operations to execute the client's callback function. The client process is
unaware of a role change event that has occurred, and as such services running on the affected node
are likely to be out of sync.
Recommended Action In order to force a resync of the current role status, restart the process that
emitted this error. If the error string indicates a low resource condition, first free up some resources.
If the message recurs, copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
SRD Messages
Error Message
%SERVICES-SRD-3-ASSERT
ASSERT failure: [chars]
Explanation The process is in an inconsistent state. The process will exit and restart. All data will be
resynchronized after the restart.
Recommended Action No action is required to recover the system, this will happen automatically.
Report this issue to your Cisco technical support representative and provide the representative with
the gathered information.
Error Message
%SERVICES-SRD-3-INIT_FAILED
Initialisation failed, module: [chars], operation:
[chars], error: [chars]
Explanation The Service Role Daemon has failed to start up. The operation being attempted is
detailed in the error message. The Service Role Daemon will be restarted automatically.
Recommended Action If the error indicates an Out Of Memory error, then attempt to increase the
available resources. Otherwise, if the error persists, contact your technical support representative
copying the error message exactly as it appears.
Error Message
%SERVICES-SRD-3-LOOP_FAILED
Unexpected error in event loop: [chars]
Explanation An unexpected error has been encountered in the main Service Role Daemon event loop.
The Service Role Daemon will be automatically restarted, and should recover by itself.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SRD-3-NOMEM
Insufficient resources: [chars]
Explanation There are insufficient resources to perform some action. The error message contains
more details about what action failed.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration. Once the memory conditions have been improved, restart
the Service Role Daemon process to allow it to resynchronize with its clients.
Error Message
%SERVICES-SRD-4-CARD_NOT_PRESENT
The role you are attempting to assign is not
supported by the node you have selected.
Explanation A node has been set to a role which is not supported. This could be because the wrong
card is at this location, or no card is there.
Recommended Action Insert a card of an appropriate type into the specified location. If you believe
that the card in the slot is of an appropriate type, ensure it is correctly booted (in IOX-RUN state
according to 'show platform'). If everything looks right, and the role is still not enacted, then contact
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-SRD-4-ERROR_PROCESSING_LRD_EVENT
SRD Unable to process OIR
notification: [chars]
Explanation The Service Role Daemon received an LRd event which it was unable to process. This
could potentially mean that a card does not have it's specified role enacted, or removed if it was
taken down.
Recommended Action Restart the service_role_daemon process to resync all roles and replay the lost
notification. If the message recurs, copy the error message exactly as it appears on the console or in
the system log, call your Cisco technical support representative and provide the representative with
the gathered information.
Error Message
%SERVICES-SRD-4-ERROR_STARTING_AGENT
Unable to update role on card with Node ID
[chars]: [chars]
Explanation The Service Role Change Agent returned an error while running on this node. The role
has not been correctly applied on the specified card.
Recommended Action Restart the service_role_agent process on the given card manually to enact the
role. Assuming no error is returned, restart the service_role_daemon process as well to resync the
state and notify all interested clients. If the message recurs, copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%SERVICES-SRD-4-MISSING_TIMER_CONTEXT
An error occurred while setting role. Role
not applied.
Explanation Required data was not available when a timer expired. A role that should be applied now
is unable to be applied.
Recommended Action Restart the service_role_daemon process to attempt to re-enable the role. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
SVII_EA_GSR Messages
Error Message
%SERVICES-SVII_EA_GSR-3-INTF_EXIST
Interface '[chars]' of type [unsigned int]
already exists as type [unsigned int]
Explanation An attempt was made to create an interface that already existed, but with a different
type. It is likely that the given interface will no longer be operating as expected.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-SVII_EA_GSR-3-NOMEM
Insufficient memory: [chars]
Explanation SVII EA ran out of memory. The exact operation being attempted is detailed in the error
message.
Recommended Action This indicates a low-memory condition. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration.
SVII_EA_STATS Messages
Error Message
%SERVICES-SVII_EA_STATS-3-CHKPT_GET_FAILURE
Failed in checkpoint interaction,
resulting in zero stats returned for [chars] (expected length [unsigned int],
found [unsigned int]): [chars]
Explanation An error occurred during periodic statistics collection for the interface specified. This
means that the statistics (as reported by e.g. 'show interface') will be inaccurate for as long as this
error is seen.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
SVII_EA Messages
Error Message
%SERVICES-SVII_EA-3-EVENT
Unrecoverable error in event loop. Error: [chars]
Explanation An error (other than EINTR) occurred in the event loop. The process must exit.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_EA-3-FORWARDER_CONNECTION
Failed to handle forwarder connection
being lost - error: [chars]
Explanation The forwarder driver has restarted, but this process was unable to handle this as the error
was unexpected. It is possible, though not necessarily true, that slow path packet processing for
some interfaces owned by this process may be broken.
Recommended Action Restarting the relevant SVI Manager process will prompt a resync, which
should get the SVI Manager process and forwarder driver back into step. If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%SERVICES-SVII_EA-3-INIT
Failure during initialization of [chars]. Error:
[chars]
Explanation A failure occurred during the initialization of the Service Virtual Interface
infrastructure. This resulted in the restart of the process.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_EA-3-SEND_FAILED
Failed during [chars] stage of sending a
'[chars]' message - Error: [chars]
Explanation A control message could not be sent from the EA to the MA. See error message for a
possible reason. An interface may now be in the wrong up/down state.
Recommended Action Restarting the relevant SVI Manager process will prompt a resync, which
should re-send the lost message. If the message recurs, copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_EA-3-SYSMGR
Failure communicating readiness to System Manager.
Error: [chars]
Explanation The process was initialized successfully but was unable to inform System Manager of
the success.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_EA-3-UNABLE_TO_RECONNECT
The Service Infrastructure was unable to
synchronize interfaces: [chars]
Explanation If the Service Infrastructure becomes out of sync with IM, then it reconnects in order to
prompt a resync. If this message is displayed then it has been able to reconnect. This may cause
configured interfaces to no longer forward traffic, or interfaces which have been shut down or
deleted to continue to do so.
Recommended Action Restarting the process that displayed the message may solve the issue, or
restarting ifmgr. If the message recurs, copy the error message exactly as it appears on the console
or in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
SVII_LRD_SPA Messages
Error Message
%SERVICES-SVII_LRD_SPA-3-STATE_UPDATE
Failed to report SPA [chars] change to
SVIA; reason: [chars]; error [chars]
Explanation A failure occurred while processing a SPA state or type change notification. Service
interfaces configured on the given SPA may not be appropriately (un)replicated.
Recommended Action Restarting the process in question should rectify the situation. If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
SVII_MGR Messages
Error Message
%SERVICES-SVII_MGR-3-ACTIVATE
Failure during activation of [chars]. Error:
[chars]
Explanation A failure occurred during the activation of the Service Virtual Interface infrastructure.
Activation occurs when the card transitions to ACTIVE state. This error resulted in the restart of the
process.
Recommended Action *RECUR*
Error Message
%SERVICES-SVII_MGR-3-EVENT
Unrecoverable error in event loop. Error: [chars]
Explanation An error (other than EINTR) occurred in the event loop. The process must exit.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-EXITING
Failure communicating exit to System Manager.
Error: [chars]
Explanation The process was unable to inform System Manager of its graceful shutdown.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-IM_STATE_SYNC_ERROR
The Service Infrastructure encountered
an error when trying to synchronize interface states with the Interface Manager
process, while [chars]. Error [chars]
Explanation The Service Application was unable to report the state of an interface that it owns to the
Interface Manager process. The interface state may be inconsistent, and may stop forwarding traffic,
or forward traffic when it appears shut down.
Recommended Action Restarting the process that displayed the message may help, & If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-INIT
Failure during initialization of [chars]. Error:
[chars]
Explanation A failure occurred during the initialization of the Service Virtual Interface
infrastructure. This resulted in the restart of the process.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-INIT_ENS
Failure to initialize ENS - retry scheduled. Error:
[chars]
Explanation A failure occurred during the initialization of ENS library in the process. This probably
indicates an underlying more severe problem, and retry will be attempted.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-SVII_MGR-3-SEND_FAILED
Failed to send a '[chars]' message - Error:
[chars]
Explanation A control message could not be sent from the MA to the EA. See error message for a
possible reason. An interface may now be in the wrong up/down state.
Recommended Action Restarting the relevant SVI Manager process will prompt a resync, which
should re-send the lost message. If the message recurs, copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-SVIA_INTF_STATE_ERROR
The Service Application for [chars]
attempted to set an invalid interface state. The interface will be taken down.
Invalid state: [chars].
Explanation The Service Application that manages the interface attempted to put the interface in a
state that is not valid. This indicates an internal error in the application. The interface will be put in
DOWN state and will cease to forward traffic.
Recommended Action recommend that restarting the process that displayed the message may help, &
If the message recurs, copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%SERVICES-SVII_MGR-3-SYSMGR
Failure communicating readiness to System Manager.
Error: [chars]
Explanation The process was initialized successfully but was unable to inform System Manager of
the success.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-UNABLE_TO_RECONNECT
The Service Infrastructure was unable
to synchronize interfaces: [chars]
Explanation If the Service Infrastructure becomes out of sync with IM, then it reconnects in order to
prompt a resync. If this message is displayed then it has been able to reconnect. This may cause
configured interfaces to no longer forward traffic, or interfaces which have been shut down or
deleted to continue to do so.
Recommended Action Restarting the process that displayed the message may solve the issue, or
restarting ifmgr. If the message recurs, copy the error message exactly as it appears on the console
or in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%SERVICES-SVII_MGR-3-UNABLE_TO_RESYNC
The Service Infrastructure was unable to
synchronize interfaces
Explanation In order to correct any problems, the Service Infrastructure will reconnect to IM to
prompt a resync. If this message is displayed then this resync is failing. This may cause configured
interfaces to no longer forward traffic, or interfaces which have been shut down or deleted to
continue to do so.
Recommended Action Firstly the processing displaying this message should be restarted. If this fails
to solve the issue, then the configuration should be removed and readded. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
VASI_EA Messages
Error Message
%SERVICES-VASI_EA-3-ADJACENCY
Error setting up adjacencies for an interface:
[chars]
Explanation An error was encountered while trying to set up adjacency information for a VASI
interface. The exact error is detailed in the error message. Packets will not be forwarded to the
affected interface.
Recommended Action It may help to restart the affected VASI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be addressed first. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-INITFAIL
Failure during initialization. Error: [chars]
Explanation A failure occurred during the initialization of the VASI EA process on a particular node.
The process will be restarted. Until the process starts successfully, any VASI interface pairs located
on that node will not come up. (If there is a standby node the interfaces should come up on the
standby).
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-INTERNAL
[chars]
Explanation An unexpected internal error has occurred in the VASI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-INTERNAL_ERR
[chars] : [chars]
Explanation An unexpected internal error has occurred in the VASI EA process. The process will
restart.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-LINK_FAIL
Error while [chars]ing [unsigned int] interfaces:
[chars]
Explanation An error occurred while attempting to join together the two halves of some VASI pairs
on the specified node. The pairs will not come up. If there is a standby node configured for the pairs,
they may come up on the standby.
Recommended Action It may help to shut down, then bring up, the VASI interface pairs in question.
Error Message
%SERVICES-VASI_EA-3-NOMEM
Insufficient memory: [chars]
Explanation Insufficient memory was available to perform an operation. The exact operation is
detailed in the error message.
Recommended Action A low memory condition has occurred: Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration. You will also
have to restart the affected VASI EA process once that is done.
Error Message
%SERVICES-VASI_EA-3-NOT_FOUND
Received request for an interface (0x[pointer])
that is not in our database
Explanation The VASI EA process received a request to process an interface that does not exist in its
database. This indicates some sort of internal inconsistency.
Recommended Action It may help to restart the VASI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-SSC_SEND
Error while sending messages to Service Director:
[chars]
Explanation A problem was encountered while trying to send a batch of messages to the Service
Director. The Service Director may not be up to date with the state of services on this node, so VASI
interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the VASI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-SSC_SEND_SRV
Error while sending message about [chars] to
Service Director: [chars]
Explanation A problem was encountered while trying to send a single message to the Service
Director. The Service Director may not be up to date with the state of this services on this node, so
the associated VASI interfaces located on this node may fail to forward packets.
Recommended Action It may help to restart the VASI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-STATE_CHANGE
An error occurred while checking the state for
'[chars]': [chars]
Explanation While the VASI EA process was checking the state for the specified interface pair, an
error was encountered. The interface pair in question may be left in an inconsistent state.
Recommended Action It may help to restart the VASI EA process. If there are any obvious resource
problems (e.g. memory exhaustion), these must be fixed first. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%SERVICES-VASI_EA-3-SVI_HW_UPD_FAIL
Error updating service infrastructure with
new hardware state: [chars]
Explanation An error was encountered whilst updating the hardware state of one or more VASI
interfaces. The exact error is detailed in the error message. The interfaces affected may no longer be
able to forward traffic.
Recommended Action It may help to restart the affected VASI EA process. If there are any obvious
resource problems (e.g. memory exhaustion), these must be addressed first. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
VASI_MA Messages
Error Message
%SERVICES-VASI_MA-3-INIT
Failed to initialize VASI interface owner process.
Stage: [chars], error: [chars]
Explanation The VASI Manager failed to startup correctly. Though it will get automatically
restarted, the error is unlikely to be recoverable.
Recommended Action *RECUR*
Error Message
%SERVICES-VASI_MA-3-INTF_CREATE_FAIL
Failed to cleanup after interface creation
failed. Error: [chars]
Explanation The VASI Manager failed to completely clean up interface state after an interface
creation failed. This will have left the system in an inconsistent state. The most likely reason for this
error is memory exhaustion.
Recommended Action Look for ways to free up memory and restart the vasimgr process.
VASI_NETIO Messages
Error Message
%SERVICES-VASI_NETIO-3-DROPPED_PACKETS
Packets have been dropped in the VASI base
capsulation, but no error counts could be updated ([chars]).
Explanation An error has occurred during packet handling in the VASI base capsulation, and no error
counters can be updated. If errors are seen for an extended period then it can be assumed that no
packets can be forwarded through VASI interfaces. This is likely to be a symptom of a problem in
the Packet Forwarding Infrastructure - earlier error messages might indicate the root cause of the
problem.
Recommended Action If the errors stop after a couple of minutes while traffic is still flowing through
the VASI interfaces then it can be assumed that the problem has resolved itself. If the problem
continues, then unconfiguring and reconfiguring the VASI interfaces could fix the issue.
Error Message
%SERVICES-VASI_NETIO-3-INIT_DEBUG
Failure of debug initialization during
[chars]. Error: [chars]
Explanation A failure occurred during the initialization of debug for the NetIO caps. If this occurred
during an upgrade operation then it will cause the NetIO process to reload. Otherwise this will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%SERVICES-VASI_NETIO-3-INIT_TRACE
Failure initializing tracing ([chars] buffer).
Error: [chars]
Explanation A failure occurred during the initialization of tracing for the NetIO caps. This will cause
the capsulation to be unloaded, and an error returned to the user.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.