Table Of Contents
Fabric Messages
FAB_SVR Messages
FABQ Messages
FABRIC_DRIVER_LITE Messages
FABRIC_DRVR Messages
FABRIC_SRVR Messages
FABRICQ_MGR Messages
FABRICQ Messages
FDI Messages
FEATURE_LPTS Messages
FGID_AGG Messages
FGID_ALLOC Messages
FGID_BCDL_CONSUMER Messages
FGID_LIB Messages
FGID_SVR Messages
FIA Messages
FIFO Messages
FSDB Messages
FSTATSA Messages
FSTATSC Messages
FSTATSS Messages
INGRESSQ_ALARM Messages
INGRESSQ_DLL Messages
INGRESSQ_LIB Messages
INGRESSQ Messages
Fabric Messages
This section contains all Fabric (hardware and software both) related System Error Messages. The following facility codes are represented in this module:
•
FAB_SVR Messages
•
FABQ Messages
•
FABRIC_DRIVER_LITE Messages
•
FABRIC_DRVR Messages
•
FABRIC_SRVR Messages
•
FABRICQ_MGR Messages
•
FABRICQ Messages
•
FDI Messages
•
FEATURE_LPTS Messages
•
FGID_AGG Messages
•
FGID_ALLOC Messages
•
FGID_BCDL_CONSUMER Messages
•
FGID_LIB Messages
•
FGID_SVR Messages
•
FIA Messages
•
FIFO Messages
•
FSDB Messages
•
FSTATSA Messages
•
FSTATSC Messages
•
FSTATSS Messages
•
INGRESSQ_ALARM Messages
•
INGRESSQ_DLL Messages
•
INGRESSQ_LIB Messages
•
INGRESSQ Messages
FAB_SVR Messages
Error Message
%FABRIC-FAB_SVR-7-ERR_ASIC_INIT
Failed to initialize the the CPU control ASIC
interface to [chars]: [chars]. Exiting...
Explanation Fabric server encountered an error while initializing the CPU control ASIC to either
receive packets from the fabricq ASIC or transmit packets from the ingressq ASIC. This is crucial
for the process and is automatically restarted on this failure.
Recommended Action If problem either persists (following a process restart) then Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_CREATE
Failed to create event connection to
EVM, Reason: [chars]([dec]). Exiting...
Explanation Fabric server encountered an error while trying to create a connection to event manager
to manage the posix message queue. This facility is deemed crucial and the process automatically
restarts on this failure.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_EVM_HANDLER
Failed to register event handler,
Reason: [chars]([dec]). Exiting...
Explanation Fabric server encountered an error while trying to register event handler for the posix
message queue. This facility is deemed crucial and the process automatically restarts on this failure.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_NOTIFY
Failed to register handler for
disconnection with EVM, Reason: [chars]([dec]). Exiting...
Explanation Fabric server encountered an error while trying to register event handler for
disconnection or connection error event. This facility is deemed crucial and the process
automatically restarts on this failure.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_OPEN
Failed to open connection with EVM,
Reason: [chars]([dec]). Exiting...
Explanation Fabric server encountered an error while trying to open connection with event manager.
This facility is deemed crucial and the process automatically restarts on this failure.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_EVM_CREATE
Failed to create the event manager. Reason:
[chars]. Exiting...
Explanation Fabric server encountered an error while attempting to create an event manager. This
failures affects the ability of the process to service various messages / pulses from other threads /
processes. This facility is deemed crucial and the process automatically restarts on this failure. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_INIT
[chars] during the initialization. Reason: [chars].
Exiting...
Explanation Fabric server encountered the specified error during the initialization sequence. This
facility is deemed crucial and hence the process is automatically restarted on this failure. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information..
Error Message
%FABRIC-FAB_SVR-7-ERR_THREAD_ATTRIBUTE
Failed to set the thread attribute:
[chars]. Exiting...
Explanation Fabric server encountered an error while setting the thread attribute during the process
initialization sequence. This is crucial for the process and is automatically restarted on this failure.
Recommended Action If the problem is experienced only by this process in the system, restart the
fabric server process by executing the following command at the CLI of the active RP: process
restart fab_svr location loc If problem either persists (following a process restart) or also noticed on
other processes then Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FAB_SVR-7-ERR_THREAD_MUTEX_INIT
Failed to initialize a mutex for client
with ID [dec]: [chars]. Exiting...
Explanation Fabric server encountered an error while creating a mutex for use by a client with the
specified ID. This is crucial for the process and is automatically restarted on this failure.
Recommended Action If the problem is experienced only by this process in the system, restart the
fabric server process by executing the following command at the CLI of the active RP: process
restart fab_svr location loc If problem either persists (following a process restart) or also noticed on
other processes then Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
FABQ Messages
Error Message
%FABRIC-FABQ-3-FATAL
FABQ: fatal error encountered, reason equals [chars]
Explanation Fabric Queue Driver encountered a fatal error and is not able recover from the error. A
reason text will be supplied. Call support with this text.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABQ-3-INIT_ERROR
Process initialization failed: ([chars]%s)
Explanation PRP fabric queue process failed to initialize. The fabric queue process handles fabric
connectivity. It initializes and starts up the threads in ToFab and FrFab components. An
unrecoverable failure of the process may prevent this route processor from communicating with
other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.
Recommended Action If a redundant route processor card has been configured: 1 - force a failover
with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor
card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where
x is the slot of route processor that generated the error. If no redundant RP is configured, you will
need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FABQ-3-PKT_INIT_ERROR
Packet carving failed to initialize: ([chars]%s)
Explanation Initial carving of a packet particle pool failed. Platform specific memory region, packet
header and particle pool configuration information are required by the generic packet manager
process (PAKMAN) to operate. A failure in packet carving initialization may prevent this route
processor from communicating with other cards in the chassis. %s - indicates the reason for the
failure. %s - is the error reason.
Recommended Action If a redundant route processor card has been configured: 1 - force a failover
with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor
card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where
x is the slot of route processor that generated the error. If no redundant RP is configured, you will
need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FABQ-3-PKT_INIT_FAIL
PKT_INIT: [chars] failed, rc equals [dec],
reason:[chars]
Explanation Packet carving function has failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABQ-3-PKT_INIT_POOL
PKT_INIT: particle_multi_pool_define failed
([chars]), rc equals [dec], reason:[chars]
Explanation Initial carving of a packet particle pool has failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABQ-3-SHOW_ERR
FABQ_SHOW: fatal error encountered: [chars]
Explanation Error while executing a show command
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABQ-6-PKT_INIT_INFO
PKT_INIT: pak mem size:[hex], pak mem start: [hex],
pak scaling:[dec]
Explanation Information on packet memory carving
Recommended Action This is information and does not require any correction.
Error Message
%FABRIC-FABQ-7-PKT_INIT_INFO
Packet initialization: pak mem size:[hex], pak mem
start: [hex], pak scaling:[dec]
Explanation Information on packet memory carving.
Recommended Action This is informational and does not require any correction.
FABRIC_DRIVER_LITE Messages
Error Message
%FABRIC-FABRIC_DRIVER_LITE-3-ERR_ASIC_ACCESS_EXCEPTION
Fabric ASIC access timed
out (reported by lite process)
Explanation This indicates that the fabric ASIC failed to acknowledge an access request from the
CPU. This can happen if the host CPU tries to access an address that is out of range for the ASIC.
Also, accessing a register from a block that is still in the logic reset state could stall this access and
subsequent accesses to the ASIC.
Recommended Action If this condition is noticed for every access to the ASIC, then the ASIC is
possibly wedged. Resetting the ASIC or reloading the fabric card will help to recover from this
condition. Copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-3-ERR_DRIVER_INIT
Initialization of fabric driver
lite failed: [chars] ; exiting...
Explanation Fabric driver encountered the annunciated error during the driver initialization. The
System Manager process (sysmgr) will automatically respawn the (sfe_drvr_lite) process, up to a
fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will
trigger node reload. After a certain number of node reloads, the shelf manager will permanently
shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-3-ERR_EVM_CREATE
Failed to create event manager for
'[chars]'
Explanation The Fabric driver was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
(sfe_drvr_lite) process, up to a fixed number of times the error is encountered, to recover. If the
problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf
manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-3-ERR_SHMEM_INIT
Shared Memory Error: [chars]
Explanation Attempt to init/open the shared memory fails
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-3-ERR_THREAD_ATTRIBUTE
FABRIC driver lite failed to
change interupt thread to an IO thread: [chars]
Explanation The Fabric driver was unable to change the interrupt thread to an IO thread. Because of
this failure, the interupt thread will not be able to receive the interupt thread events. The System
Manager process (sysmgr) will automatically respawn this (sfe_drvr_lite) process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
node reload. After a certain number of node reloads, the shelf manager will permanently shutdown
the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-4-ERR_LTRACE_INIT
Fabric driver lite failed to
initialize the ltrace - rc equals [chars]
Explanation The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the
system should stll function as normal, with the exception that ltrace will not be available for sfe_drvr
process.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRIVER_LITE-6-ASIC_INITIALIZED
Fabric ASICs initialized (reported
by lite process)
Explanation This indicates Fabric ASICs are initialized and is expected during normal operation.
Recommended Action No action is required.
FABRIC_DRVR Messages
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_ASIC_ACCESS_EXCEPTION
Fabric ASIC access timed out.
Explanation This indicates that the fabric ASIC failed to acknowledge an access request from the
CPU. This can happen if the host CPU tries to access an address that is out of range for the ASIC.
Also, accessing a register from a block that is still in the logic reset state could stall this access and
subsequent accesses to the ASIC.
Recommended Action If this condition is noticed for every access to the ASIC, then the ASIC is
possibly wedged. Resetting the ASIC or reloading the fabric card will help to recover from this
condition. Copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_BOARD_PLD_VERSION
Fabric Board PLD Version ([dec]) not
supported. Upgrade to latest.
Explanation This indicates that the fabric board is running with PLD version that is not supported.
Version lower than (0x1c) is not supported. Please upgrade to the latest PLD Version.
Recommended Action Shut down the plane associated to this fabric card, and upgrade the PLD
Version of this board. Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_DRV_INIT
Initialization of fabric driver failed:
[chars] ; exiting...
Explanation Fabric driver encountered the annunciated error during the driver initialization. The
System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
node reload. After a certain number of node reloads, the shelf manager will permanently shutdown
the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_EVM_CREATE
Failed to create event manager for
'[chars]'
Explanation The Fabric driver was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
(sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem
continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf
manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_FGID_REFRESH
Request [dec] to refresh FGID entry
[hex].
Explanation An FGID entry is disabled following a parity error. A request to refresh the entry is
issued.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_FGID_REFRESH_RETRY
Failed to refresh FGID entry.
Reload the fabric card.
Explanation An FGID entry is disabled following a parity error. Request to refresh the entry wasn't
entertained. This will reload the fabric card to recover.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_FGID_WRITE
Device(s) being reset. [chars] FGID write
to offset [hex] aborted.
Explanation One or more ASICs for the stage on the fabric card are in being reset. Hence this
multicast FGID write operation for the specified stage is aborted.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_POD_INIT
Failed to initialize POD for node: [hex],
error : [chars]; exiting...
Explanation Fabric Driver failed to initialize one of the POD hardware modules. The System
Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number
of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node
reload. After a certain number of node reloads, the shelf manager will permanently shutdown the
node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_THREAD_ATTRIBUTE
FABRIC driver failed to change
interupt thread to an IO thread: [chars]
Explanation The Fabric driver was unable to change the interrupt thread to an IO thread. Because of
this failure, the interupt thread will not be able to receive the interupt thread events. The System
Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number
of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node
reload. After a certain number of node reloads, the shelf manager will permanently shutdown the
node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_TIMER_START
Leaf Timer Failed to start. Timer Type:
[dec].
Explanation Fabric driver could not start timer.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-3-ERR_WAITING_FOR_TOPO_TIMED_OUT
Driver timed out waiting
for topology information. Attempt re-request for topology.
Explanation This indicates that the driver has not received the necessary topology information to
initialize the asic. The driver will continually re-request topology. This message can also be seen in
a multichassis system when a fabric card is pulled out or powered down and the other end is still up
and running.
Recommended Action Check if all the required fabric cards are UP and running.
Error Message
%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_GLACIAL
[chars] ; Node Key equals [hex]
Explanation The Fabric driver encountered the annunciated error. For Error Node Keys - 0x1050016;
0x1050018; 0x105001A : This indicates a hardware problem in Fabric ASIC. Sysmgr will reload the
node up to a fixed number of times the error is encountered, to recover. After a certain number of
node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_NO_LIMIT
[chars]
Explanation The fabric driver encountered the annunciated error. Sysmgr will reload the node up to
a fixed number of times the error is encountered, to recover. After a certain number of node reloads,
the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_SLOW
[chars]
Explanation The fabric driver encountered the annunciated error. Sysmgr will reload the node up to
a fixed number of times the error is encountered, to recover. After a certain number of node reloads,
the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-4-ERR_LTRACE_INIT
Fabric driver failed to initialize the
ltrace - rc equals [chars]
Explanation The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the
system should stll function as normal, with the exception that ltrace will not be available for sfe_drvr
process.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-6-ASIC_INITIALIZED
Fabric ASICs initialized
Explanation This indicates Fabric ASICs are initialized and is expected during normal operation.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-7-ERR_BP_CFG
[chars]: Error in Back pressure configuration,
BP Groups : [dec], [dec], [dec]
Explanation The Fabric driver encountered an error in back pressure configuration. This indicates
BP configuration received from the fabric control software is incorrect. If this condition prevails, it
could impact data traffic when fabric gets congested.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-7-ERR_DEBUG_REG
Fabric driver failed to register with the
debug; rc equals [chars]
Explanation The Fabric driver was unable to register with the debug. The System Manager process
(sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error
is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-7-ERR_INTERNAL_SW
[chars]
Explanation The Fabric driver encountered the annunciated internal SW error. The System Manager
process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-7-ERR_LINK_TOPO
Topology mismatch for [chars]
Explanation The upstream information received from idle cells on this link does not match with
FSDB information.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_DRVR-7-ERRRATE_EXCEED_DEBUG
[chars]
Explanation The fabric driver encountered the annunciated error. The Fabric driver and the System
should still continue to function as normal.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_DRVR-7-LINK_SHUT_DOWN
Fabric Link: [chars] - Shutdown: [chars]
Explanation The Fabric driver encountered an error on the annunciated Fabric Switching Element
link and the link is brought down.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FABRIC_SRVR Messages
Error Message
%FABRIC-FABRIC_SRVR-3-ERR_DRV_INIT
Initialization of fabric driver failed:
[chars] ; exiting...
Explanation Fabric driver encountered the annunciated error during the driver initialization. The
System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
node reload. After a certain number of node reloads, the shelf manager will permanently shutdown
the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-3-ERR_EVM_CREATE
Failed to create event manager for
'[chars]'
Explanation The Fabric driver was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
(sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem
continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf
manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-3-RESET_ALL_ASICS
FDI request to reset all the ASICs on the
fabric board.
Explanation Process a request received from FSDB to reset all the ASICs on the fabric card.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_SRVR-4-ERR_ECM_CREATE
Failed to create Event Connection Manager :
[chars]
Explanation The Fabric driver was unable to create an event connection manager for EDM. Fabric
driver and the System should continue to function as normal, with the exception that the 'show'
commands for Fabric driver will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-4-ERR_ECM_NOTIFY
Failed to register with ECM to receive
notifications : [chars]
Explanation The Fabric driver was unable register with ECM to receive notifications when the
connection to Sysdb goes down/up/closed. Fabric driver and the System should continue to function
as normal, with the exception that the 'show' commands for Fabric driver will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-4-ERR_LTRACE_INIT
Fabric driver failed to initialize the
ltrace - rc equals [chars]
Explanation The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the
system should stll function as normal, with the exception that ltrace will not be available for sfe_drvr
process.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_SRVR-6-FAB_MODULE
[chars]
Explanation This is to give infomation regarding fabric module type.
Recommended Action No action is required.
Error Message
%FABRIC-FABRIC_SRVR-7-ERR_BAG_REG
[chars]
Explanation The Fabric driver was unable to register Fabric driver bags. The Fabric driver and the
System should continue to function as normal, with the exception that the 'show' commands for
Fabric driver will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-7-ERR_DEBUG_INIT
Fabric driver failed to initialize the
debug; rc equals [chars]
Explanation The Fabric driver was unable to initialize debug. The System Manager process (sysmgr)
will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-7-ERR_DEBUG_REG
Fabric driver failed to register with the
debug; rc equals [chars]
Explanation The Fabric driver was unable to register with the debug. The System Manager process
(sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error
is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-7-ERR_INTERNAL_SW
[chars]
Explanation The Fabric driver encountered the annunciated internal SW error. The System Manager
process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FABRIC_SRVR-7-ERR_SYSDB_EDM_REG
[chars]
Explanation The Fabric driver was unable to become an external data manager (EDM) despite having
a connection to SysDB. The operation will be retried. The Fabric driver and the System should
continue to function as normal, with the exception that the 'show' commands for Fabric driver will
not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FABRICQ_MGR Messages
Error Message
%FABRIC-FABRICQ_MGR-3-ERR_INIT
Initialization Error: [chars] Reason: [chars].
Exiting.
Explanation Fabricq manager encountered a fatal error and is not able recover from the error. A
reason text will be supplied call support with this text.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-3-ERR_MEM_ALLOC
Error Allocating [dec] bytes of memory
Explanation Fabricq encountered a fatal memory allocation error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-4-ERR_CHKPT_INIT
Checkpoint Initialization failed. Reason:
[chars]
Explanation Fabricq Checkpoint Init error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_BAG_REG
Bag register failed for rules. Reason: [chars]
Explanation EDM Bags are used to share information between components using sysdb. This Error
indicates that bag registration failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_CLIENT_REG
Client [chars] failed. Reason: [chars]
Explanation Fabricq Manager client Registration/Unregistration error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_DLL_INIT
Dll Initialization for [chars] failed.
Reason: [chars]
Explanation Fabricq driver tried to register for a dll but it encountered an error. The driver might lose
some of its functionality.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_EVM_CREATE
Event Manager create failed for [chars].
Reason: [chars]
Explanation Fabricq Event Manager create error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_EVM_NOTIFY
Event Manager notify failed for [chars].
Reason: [chars]
Explanation Fabricq Event Manager notify error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_LWM_EVENT_BLOCK
LWM Event Manager event block failed.
Reason: [chars]
Explanation Fabricq Event Manager event block error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_LWM_REPLY
An error occurred during LWM message reply.
Reason: [chars]
Explanation Fabricq LWM reply error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ_MGR-7-ERR_SYSDB_EDM_REG
Sysdb Register EDM failed. Reason:
[chars]
Explanation Fabricq Sysdb Register EDM error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
FABRICQ Messages
Error Message
%FABRIC-FABRICQ-3-ERR_ASIC_FCRAM_ASSERT
Assert error in Fabricq ASIC [dec].
FCRAM Channel [dec].
Explanation Fabricq ASIC encountered a FCRAM Channel error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-3-ERR_BIST
Error during [chars] BIST
Explanation Fabricq BIST error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ-3-ERR_INIT
Instance: [dec]. Error: [chars]
Explanation Fabricq Asic driver encountered a fatal error and is not able recover from the error. A
reason text will be supplied call support with this text.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ-3-PCL_CCNT_ERR
Major error in PCL of fabricq asic [dec]: [chars]
data.
Explanation Sponge encountered a PCL cell count mistmatch error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-3-PCL_CSLOT_SYNC
Major internal error in PCL of fabricq asic
[dec]: [chars].
Explanation Sponge encountered a PCL internal error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-3-PCL_PKT
Minor error in PCL of fabricq asic [dec]. [chars]
Explanation Sponge encountered a PCL Packet error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-3-PCL_XCELL_ERR
Major error in PCL of fabricq asic [dec]: [chars]
Explanation Sponge encountered a PCL extra cell error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-3-RESET
Reseting Fabricq ASIC Device [dec]. Reason: [chars]
Explanation Reseting Fabricq ASIC on detecting fatal error.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ-4-ERR_ASIC_MBE
Fabricq Asic [dec] detected multibit error(s).
Details: [chars]
Explanation Fabricq Asic encountered a memory uncorrectable error
Recommended Action The multi-bit errors can happen in one of many blocks of the fabricq ASIC.
One of them is the Fabric Interface (FI). If these error messages are generated for short intervals for
FI links when a fabric card is disabled / reloaded / OIR'ed, then they are harmless. If these messages
continue for more than 2 minutes, with incrementing uncorrectable error (UCE) counters, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information. Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FABRICQ-4-ERR_ASIC_PARITY
Fabricq Asic [dec] detected parity error(s).
Details: [chars]
Explanation Fabricq Asic encountered a parity error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-ERR_ASIC_SN_LINK
Fabricq ASIC [dec] encountered a CpuCtrl
[chars] error
Explanation Fabricq ASIC encountered a CpuCtrl CRC/Sync error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-FI_LINK_ALARM
Link Alarm on Fabricq ASIC [dec] link [dec]
Explanation Fabricq ASIC encountered a link alarm
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-FI_LINK_BRINGDOWN
Fabric link [dec] on ASIC [dec] may be
brought down due to too many errors
Explanation A fabric link was brought down due to too many UCE or parity errors.
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-FI_TOPOLOGY
Fabric topology inconsistency detected for ASIC
[unsigned int] link [unsigned int] (observed topology information: [hex],
expected: [hex])
Explanation An inconsistency between the expected and observed topologies of the fabric was
detected.
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-MI_WEDGE
Major error in Fabricq ASIC [dec]. MI [chars] Wedged
Explanation Fabricq ASIC encountered a MI Unicast/Multicast Wedge error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-4-PSN_WRAP
Major error in PCL of Fabricq asic [dec]: [chars] .
[hex] spo_pcl_mem_ppbr [hex][hex]%08x[hex]%08x[hex]%08x[hex]
Explanation Fabricq encountered a PCL Packet Sequence Wrap error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-5-ERR_RES_PROG
Error during Resource Programming [chars]
[unsigned int] Reason: [chars]
Explanation An error occured while the Fabricq driver was trying to create queues for an interface.
This may leave one or more interfaces out of operation.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FABRICQ-5-MI_BPDECODE
Major error in Fabricq ASIC [dec]. MI [chars]
Backpressure decode error
Explanation Fabricq ASIC encountered a MI Unicast/Multicast BP Decode error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-6-ERR_ASIC_EOP
Minor error in Fabricq ASIC [dec]. [chars] End of
Packet error
Explanation Fabricq ASIC encountered a Unicast/Multicast Unexpected/Missing End Of Packet
error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-6-ERR_ASIC_GENERIC
Fabric Asic [dec] encountered generic
error(s). Details: [chars]
Explanation Fabricq encountered an interrupt that has exceeded its threshold value. Software takes
appropriate action to log and fix the error.
Recommended Action No action is required.
Error Message
%FABRIC-FABRICQ-6-ERR_ASIC_OOR
Fabricq Asic [dec] encountered [chars] Out Of
Resources error.
Explanation Fabricq encountered an out of resources error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-FABRICQ-6-ERR_ASIC_SBE
Fabricq Asic [dec] detected single bit error(s).
Details: [chars]
Explanation Fabricq Asic encountered a memory correctable error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-6-SPI_FBP
Minor error: Cluster: [dec] in Fabricq ASIC [dec] has
SPI FBP [chars] error
Explanation The Fabricq asic encounted a fabric backpressure error. These sort of errors are to be
expected during bootup or during OIR events, and are harmless for the vast majority of the time. The
only time they would signify a serious error is if they recur for long periods.
Recommended Action If these messages are recurring and/or you're seeing other faults (such as traffic
loss) then contact your support agent.
Error Message
%FABRIC-FABRICQ-6-URG_CTX
Minor error in PCL of Fabricq asic [dec]. Urgent
Context exceeded 5 equals [hex]
Explanation Fabricq encountered a PCL Urgent Context error
Recommended Action *SUPPORT*
Error Message
%FABRIC-FABRICQ-7-ERR_DMA
Error during DMA transfer: Source Addr [hex], Dest Addr
[pointer]. Reason: [chars]
Explanation An error occurred while a DMA transfer initiated by the FQM process was taking place.
This means certain data requested by the FQM process will not be available.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
FDI Messages
Error Message
%FABRIC-FDI-2-ERR_CONNECTION
[chars]; Conn_id equals [dec] Conn_name equals
[chars]
Explanation The FDI library encountered the annunciated connection error.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-2-ERR_INTERNAL_SW
[chars] ; rc equals [chars]
Explanation The FDI encountered the annunciated internal sw error.
Recommended Action No action is required.
Error Message
%FABRIC-FDI-2-ERR_MSG_TYPE
FDI received incorrect message type - [dec] from mid
([dec]:[dec]:[dec])
Explanation FDI received incorrect message type and failed to process the message. The System
Manager process (sysmgr) will automatically respawn the process, up to a fixed number of times the
error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a
certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-3-ERR_BUFF_Q
FDI Buffers are full; Conn_id [dec]. Data_Size [dec].
Buffer_states ([dec] [dec])
Explanation FDI buffers are full and FDI can't buffer any more messages. Buffer will fill up for 2
main reasons: 1. Receiver is blocked and not able to return ack 2. Some kind of transport problem
In such cases, FDI would flap the connection and flush the buffers hoping that conditions 1 or 2 were
transient.
Recommended Action Examine the state of GSP on the node of the FDI application. Collect gsp stats
for the sender and receiver application. Also determine if receiver application was ever blocked
during the time buffer went full. If the message recurs, copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-7-ERR_COMM_SYSTEM_ERROR
IPC non blocking communication failed to
group id: [dec], tag [hex] - id [dec], seq [dec], status [dec]: [chars]
Explanation The FDI Library uses gsp_group_memberset_nb ( non blocking api ). Any errors are
communicated back via a callback. These errors are considered bad, since it is likely a member did
not receive a message. These errors returned are communicated via this msg. This may indicate
some transport issue.
Recommended Action Restart application may be required, if messages continued to be logged.
Error Message
%FABRIC-FDI-7-ERR_DEBUG_CLEAN
FDI library failed to cleanup FDI debug info in
debug infrastructure ; rc equals [chars]
Explanation The FDI library was unable to cleanup FDI debug info in debug infrastructure. The
System should still continue to function as normal.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-7-ERR_DEBUG_INIT
FDI library failed to initialize debug for fdi -
[chars]; rc equals [chars]
Explanation The FDI library was unable to initialize debug. The FDI component and the System
should still continue to function as normal, with the exception that the debugs will not be available
for FDI.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-7-ERR_DEBUG_REG
FDI library failed to register with debug
infrastructure ; rc equals [chars]
Explanation The FDI library was unable to register with debug infrastructure. The FDI component
and the System should still continue to function as normal, with the exception that the debugs will
not be available for FDI.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-7-ERR_EDM_INIT
[chars]; rc equals [chars]
Explanation The FDI Library encountered the annunciated EDM Initialization error. The System
should still continue to function as normal, with the exception that the 'show' commands for FDI
will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FDI-7-ERR_MEM_ALLOC
FDI failed to allocate [dec] bytes
Explanation The FDI was unable to allocate memory.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-FDI-7-ERR_MEMBER_ALREADY_EXISTS
Member [chars] entry already exists and
registered. Updating with new member info.
Explanation The FDI Library has received a new member notification for a member that already
exists in the FDI db, and registered. Possible that we failed to cleanup old member, or a delayed new
member msg. There should be no system impact as FDI will just update with the latest info.
Recommended Action No action is required.
Error Message
%FABRIC-FDI-7-ERR_MSG_SEQ_GT
Out of sequence (greater than) message received from
[chars] [chars] reset connection.
Explanation The FDI Library encountered an internal error with a message received. Since one
message is active at one time, the message received should be the next expected seqnum. This may
indicate system resource issue, or a period where system is heavily loaded. If message persists,
application may need to be restarted.
Recommended Action Restart application may be required, if messages continued to be logged.
FEATURE_LPTS Messages
Error Message
%FABRIC-FEATURE_LPTS-3-ERR_DOUBLE_FREE
Double free of FGID [dec]
Explanation --
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FEATURE_LPTS-3-ERR_FGID_DB_RETRIES_EXCEEDED
Number of unknown errors
from FGID-DB ([dec]) has exceeded maximum
Explanation A software error occurred, when the PA attempted to allocate FGID's from the FGID
aggregator.
Recommended Action The process will attempt to recover by restarting. Copy the error message
exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FEATURE_LPTS-3-ERR_UNALLOCATED_FREE
Attempt to free unallocated FGID
[dec]
Explanation --
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FEATURE_LPTS-3-ERR_UNKNOWN_FGID_DB_ERROR
Unknown error from FGID-DB,
[chars] FGID [dec] [[dec]]([dec], [dec]): [chars]
Explanation --
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
FGID_AGG Messages
Error Message
%FABRIC-FGID_AGG-3-ERR_DEBUG_INIT
fgid_aggregator unable to initialize dbg ; rc
equals [chars]
Explanation The FGID Aggregator was unable to initialize debug. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_DEBUG_INIT
fgid_aggregator unable to initialize dbg ; rc
equals [chars]
Explanation The FGID Aggregator was unable to initialize debug. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_EVM_CREATE
FGID Aggregator failed to create [chars] evm ;
rc equals [chars]
Explanation The FGID aggregator was unable to create an event manager for processing messages
and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_EVM_CREATE
FGID Aggregator failed to create [chars] evm ;
rc equals [chars]
Explanation The FGID aggregator was unable to create an event manager for processing messages
and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_EVM_SYNC_ATTACH
FGID Aggregator failed to attach [chars]
to evm ; rc equals [chars]
Explanation The FGID Aggregator was unable to attach the indicated event handler to the event
manager. The System Manager process (sysmgr) will automatically respawn this process, up to a
fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will
trigger node reload. After a certain number of node reloads, the shelf manager will permanently
shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_EVM_SYNC_ATTACH
FGID Aggregator failed to attach [chars]
to evm ; rc equals [chars]
Explanation The FGID Aggregator was unable to attach the indicated event handler to the event
manager. The System Manager process (sysmgr) will automatically respawn this process, up to a
fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will
trigger node reload. After a certain number of node reloads, the shelf manager will permanently
shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_GSP
[chars]: rc equals [chars]
Explanation The FGID Aggregator was unable to create/join GSP group. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_GSP
[chars]: rc equals [chars]
Explanation The FGID Aggregator was unable to create/join GSP group. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_INTERNAL_SW
[chars]; [chars]
Explanation The FGID Aggregator encountered the annunciated SW error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_INTERNAL_SW
[chars]; [chars]
Explanation The FGID Aggregator encountered the annunciated SW error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_MEM_ALLOC
FGID Aggregator unable to allocate [dec] bytes
Explanation The FGID Aggregator was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_MEM_ALLOC
FGID Aggregator unable to allocate [dec] bytes
Explanation The FGID Aggregator was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_SYSMGR
[chars]; rc equals [chars]
Explanation The FGID Aggregator encountered the annunciated sysmgr error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-3-ERR_SYSMGR
[chars]; rc equals [chars]
Explanation The FGID Aggregator encountered the annunciated sysmgr error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_AGG-7-ERR_LTRACE_INIT
FGID Aggregator failed to initialize the
ltrace file [chars] : [chars]
Explanation The FGID Aggregator Could not open the annunciated ltrace buffer. The FGID
component and the system should stll function as normal, with the exception that ltrace will not be
available for fgid_aggregator process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_AGG-7-ERR_LTRACE_INIT
FGID Aggregator failed to initialize the
ltrace file [chars] : [chars]
Explanation The FGID Aggregator Could not open the annunciated ltrace buffer. The FGID
component and the system should stll function as normal, with the exception that ltrace will not be
available for fgid_aggregator process.
Recommended Action No action is required.
FGID_ALLOC Messages
Error Message
%FABRIC-FGID_ALLOC-3-ERR_EVM_CREATE
FGID Allocator failed to create [chars] evm;
rc equals [chars]
Explanation The FGID allocator was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_EVM_CREATE
FGID Allocator failed to create [chars] evm;
rc equals [chars]
Explanation The FGID allocator was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_GSP
[chars]: rc equals [chars]
Explanation The FGID Allocator encountered the annunciated GSP error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_GSP
[chars]: rc equals [chars]
Explanation The FGID Allocator encountered the annunciated GSP error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_INTERNAL_SW
[chars] ; rc equals [chars]
Explanation The FGID Allocator encountered the annunciated internal SW error. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_INTERNAL_SW
[chars] ; rc equals [chars]
Explanation The FGID Allocator encountered the annunciated internal SW error. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_MEM_ALLOC
FGID Allocator failed to allocate [dec] bytes
Explanation The FGID Allocator was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_MEM_ALLOC
FGID Allocator failed to allocate [dec] bytes
Explanation The FGID Allocator was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_SYSMGR
[chars]; rc equals [chars]
Explanation The FGID Allocator encountered the annunciated sysmgr error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-3-ERR_SYSMGR
[chars]; rc equals [chars]
Explanation The FGID Allocator encountered the annunciated sysmgr error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_BAG_REG
FGID allocator failed to register FGID bags; rc
equals [chars]
Explanation The FGID allocator was unable to register FGID bags. The FGID component and the
System should continue to function as normal, with the exception that the 'show' commands for
FGID allocator will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_BAG_REG
FGID allocator failed to register FGID bags; rc
equals [chars]
Explanation The FGID allocator was unable to register FGID bags. The FGID component and the
System should continue to function as normal, with the exception that the 'show' commands for
FGID allocator will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_INIT
FGID Allocator failed to initialize the
checkpoint library ; rc equals [chars]
Explanation The FGID Allocator was unable to initialize the checkpoint library. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_INIT
FGID Allocator failed to initialize the
checkpoint library ; rc equals [chars]
Explanation The FGID Allocator was unable to initialize the checkpoint library. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_ITERATE_START
FGID Allocator failed to start to
iterate Checkpoint table [chars]; rc equals [chars]
Explanation The FGID Allocator was unable to start to iterate checkpoint table. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_ITERATE_START
FGID Allocator failed to start to
iterate Checkpoint table [chars]; rc equals [chars]
Explanation The FGID Allocator was unable to start to iterate checkpoint table. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_REG
FGID Allocator failed to register the
Checkpoint table [chars] ; rc equals [chars]
Explanation The FGID Allocator was unable to register the checkpoint table. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_CHKPT_REG
FGID Allocator failed to register the
Checkpoint table [chars] ; rc equals [chars]
Explanation The FGID Allocator was unable to register the checkpoint table. The fgid_allocator
process may need restarting, if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_DEBUG_INIT
FGID Allocator failed to initialize debug ;
rc equals [chars]
Explanation The FGID Allocator failed to initialize debug. The FGID component and the System
should still continue to function as normal, with the exception that the debugs will not be available
fgid_allocator process.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_DEBUG_INIT
FGID Allocator failed to initialize debug ;
rc equals [chars]
Explanation The FGID Allocator failed to initialize debug. The FGID component and the System
should still continue to function as normal, with the exception that the debugs will not be available
fgid_allocator process.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_LTRACE_INIT
FGID Allocator failed to initialize the
ltrace file [chars]; rc equals [chars]
Explanation The FGID Allocator could not open the annunciated ltrace buffer. The FGID component
and the system should function as normal, with the exception that ltrace will not be available for
fgid_aggregator process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_LTRACE_INIT
FGID Allocator failed to initialize the
ltrace file [chars]; rc equals [chars]
Explanation The FGID Allocator could not open the annunciated ltrace buffer. The FGID component
and the system should function as normal, with the exception that ltrace will not be available for
fgid_aggregator process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_SYSDB_BIND
FGID Allocator failed to bind to Sysdb name
space [chars]; rc equals [chars]
Explanation The FGID-DB allocator unable to bind to sysdb name space. The fgid_allocator may
need restarting if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_SYSDB_BIND
FGID Allocator failed to bind to Sysdb name
space [chars]; rc equals [chars]
Explanation The FGID-DB allocator unable to bind to sysdb name space. The fgid_allocator may
need restarting if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_SYSDB_EDM_REG
FGID allocator failed to perform EDM
registration; rc equals [chars]
Explanation The FGID allocator was unable to become an external data manager (EDM) despite
having a connection to SysDB. The operation will be retried. The FGID component and the System
should continue to function as normal, with the exception that the 'show' commands for FGID
allocator will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_ALLOC-7-ERR_SYSDB_EDM_REG
FGID allocator failed to perform EDM
registration; rc equals [chars]
Explanation The FGID allocator was unable to become an external data manager (EDM) despite
having a connection to SysDB. The operation will be retried. The FGID component and the System
should continue to function as normal, with the exception that the 'show' commands for FGID
allocator will not be available.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FGID_BCDL_CONSUMER Messages
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BCDL
[chars] ; rc equals [chars]
Explanation The BCDL Consumer process has encountered the annunciated BCDL error. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BCDL
[chars] ; rc equals [chars]
Explanation The BCDL Consumer process has encountered the annunciated BCDL error. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BOARD_TYPE
FGID BCDL Consumer failed to get
hardware board type: rc equals [chars]
Explanation The FGID BCDL Consumer was unable to get the board type.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BOARD_TYPE
FGID BCDL Consumer failed to get
hardware board type: rc equals [chars]
Explanation The FGID BCDL Consumer was unable to get the board type.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_DEBUG_INIT
The FGID BCDL Consumer Failed to
initialize debug; rc equals [chars]
Explanation The FGID BCDL Consumer was unable to initialize debug. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_DEBUG_INIT
The FGID BCDL Consumer Failed to
initialize debug; rc equals [chars]
Explanation The FGID BCDL Consumer was unable to initialize debug. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_EVM
[chars] : [chars]
Explanation The FGID BCDL consumer encountered the annunciated Event Manager Error. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_EVM
[chars] : [chars]
Explanation The FGID BCDL consumer encountered the annunciated Event Manager Error. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FDI_CLIENT_REG
Unable to perform FDI client
registration; rc equals [chars]
Explanation The FGID BCDL Consumer was unable to register with the FDI client. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FDI_CLIENT_REG
Unable to perform FDI client
registration; rc equals [chars]
Explanation The FGID BCDL Consumer was unable to register with the FDI client. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_DOWNLOAD_DONE_NOTIF
FGID BCDL Consumer
failed to notify SFE driver about FGID download complete; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while notifying the SFE driver about
FGID download completion. This indicates a problem with communication between SFE_DRVR
and FGID BCDL consumer. Restart SFE driver manually.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_DOWNLOAD_DONE_NOTIF
FGID BCDL Consumer
failed to notify SFE driver about FGID download complete; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while notifying the SFE driver about
FGID download completion. This indicates a problem with communication between SFE_DRVR
and FGID BCDL consumer. Restart SFE driver manually.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_SET
FGID BCDL Consumer failed to set FGID
[chars] bitmap; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while setting S2 or S3 bitmap. This
indicates a problem with the communication between the SFE driver and the FGID BCDL consumer.
The FGID BCDL consumer and/or SEA driver may need restarting if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_SET
FGID BCDL Consumer failed to set FGID
[chars] bitmap; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while setting S2 or S3 bitmap. This
indicates a problem with the communication between the SFE driver and the FGID BCDL consumer.
The FGID BCDL consumer and/or SEA driver may need restarting if the errors persist.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_RACK_NUM
FGID BCDL Consumer failed to get the
rack value; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while retrieving the rack value from
nodeid. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
node reload. After a certain number of node reloads, the shelf manager will permanently shutdown
the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_RACK_NUM
FGID BCDL Consumer failed to get the
rack value; rc equals [chars]
Explanation The FGID BCDL Consumer encountered an error while retrieving the rack value from
nodeid. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
node reload. After a certain number of node reloads, the shelf manager will permanently shutdown
the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_USAGE
Invalid argument. USAGE: [chars]
Explanation The FGID BCDL consumer process was invoked with an unknown argument. The
BCDL Consumer process was started with an invalid parameter. This is not an expected field event
and details about software versions and the .startup file should be returned to engineering.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-3-ERR_USAGE
Invalid argument. USAGE: [chars]
Explanation The FGID BCDL consumer process was invoked with an unknown argument. The
BCDL Consumer process was started with an invalid parameter. This is not an expected field event
and details about software versions and the .startup file should be returned to engineering.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-7-ERR_LTRACE_INIT
FGID BCDL Consumer failed to
initialize the ltrace file [chars] : rc equals [chars]
Explanation The FGID BCDL Consumer could not open the annunciated ltrace buffer. The FGID
component and the system should function as normal, with the exception that ltrace will not be
available for FGID BCDL Consumer process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_BCDL_CONSUMER-7-ERR_LTRACE_INIT
FGID BCDL Consumer failed to
initialize the ltrace file [chars] : rc equals [chars]
Explanation The FGID BCDL Consumer could not open the annunciated ltrace buffer. The FGID
component and the system should function as normal, with the exception that ltrace will not be
available for FGID BCDL Consumer process.
Recommended Action No action is required.
FGID_LIB Messages
Error Message
%FABRIC-FGID_LIB-7-ERR_DEBUG_INIT
FGID library failed to initialize the debug ;
rc equals [chars].
Explanation The FGID library failed to initialize debug. The FGID component and the system should
still function as normal, with the exception that the debugs will not be available for FGID library.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_LIB-7-ERR_DEBUG_INIT
FGID library failed to initialize the debug ;
rc equals [chars].
Explanation The FGID library failed to initialize debug. The FGID component and the system should
still function as normal, with the exception that the debugs will not be available for FGID library.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_LIB-7-ERR_LTRACE_INIT
FGID library failed to initialize the ltrace
; rc equals [chars].
Explanation The FGID library failed to initialize ltrace. The FGID component and the system should
still function as normal, with the exception that the ltrace will not be available for FGID library.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_LIB-7-ERR_LTRACE_INIT
FGID library failed to initialize the ltrace
; rc equals [chars].
Explanation The FGID library failed to initialize ltrace. The FGID component and the system should
still function as normal, with the exception that the ltrace will not be available for FGID library.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FGID_SVR Messages
Error Message
%FABRIC-FGID_SVR-3-ERR_BCDL
[chars]; rc equals [chars]
Explanation The FGID Server encountered the annunciated BCDL error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_BCDL
[chars]; rc equals [chars]
Explanation The FGID Server encountered the annunciated BCDL error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_DSC
Failed to register for DSC notification; rc equals
[chars]
Explanation The FGID Server encountered DSC error. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node
reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_DSC
Failed to register for DSC notification; rc equals
[chars]
Explanation The FGID Server encountered DSC error. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node
reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_EVM_CREATE
FGID Server failed to create [chars] evm; rc
equals [chars]
Explanation The FGID Server was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_EVM_CREATE
FGID Server failed to create [chars] evm; rc
equals [chars]
Explanation The FGID Server was unable to create an event manager for processing messages and
hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. If the problem continues,
sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will
permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_EVM_SYNC_ATTACH
FGID Server failed to attach [chars] evm;
rc equals [chars]
Explanation The FGID Server was unable to attach the indicated event handler to the event manager.
The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number
of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node
reload. After a certain number of node reloads, the shelf manager will permanently shutdown the
node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_EVM_SYNC_ATTACH
FGID Server failed to attach [chars] evm;
rc equals [chars]
Explanation The FGID Server was unable to attach the indicated event handler to the event manager.
The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number
of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node
reload. After a certain number of node reloads, the shelf manager will permanently shutdown the
node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_GSP
[chars] ; rc equals [chars]
Explanation The FGID-DB server encountered the annunciated GSP error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_GSP
[chars] ; rc equals [chars]
Explanation The FGID-DB server encountered the annunciated GSP error. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_INTERNAL_SW
[chars]; [chars]
Explanation The FGID Server encountered the annunciated SW error. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_INTERNAL_SW
[chars]; [chars]
Explanation The FGID Server encountered the annunciated SW error. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_MEM_ALLOC
FGID Server unable to allocate [dec] bytes
Explanation The FGID Server was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_MEM_ALLOC
FGID Server unable to allocate [dec] bytes
Explanation The FGID Server was unable to allocate memory. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_USAGE
FGID Server : Server Id requested [chars] is not a
allowed server_id
Explanation Incorrect command line parameters were passed to the FGID Server, and so it failed to
start.
Recommended Action Check the startup arguments passed to FGID-DB. A default configuration will
be used if no parameters are passed. Copy the error message exactly as it appears on the console or
in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%FABRIC-FGID_SVR-3-ERR_USAGE
FGID Server : Server Id requested [chars] is not a
allowed server_id
Explanation Incorrect command line parameters were passed to the FGID Server, and so it failed to
start.
Recommended Action Check the startup arguments passed to FGID-DB. A default configuration will
be used if no parameters are passed. Copy the error message exactly as it appears on the console or
in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%FABRIC-FGID_SVR-7-ERR_LTRACE_INIT
FGID Server failed to initiaize the ltrace
file [chars]; rc equals [chars]
Explanation The FGID Server Could not open the annunciated ltrace buffer. The FGID component
and the system should function as normal, with the exception that ltrace will not be available for
fgid_server process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_SVR-7-ERR_LTRACE_INIT
FGID Server failed to initiaize the ltrace
file [chars]; rc equals [chars]
Explanation The FGID Server Could not open the annunciated ltrace buffer. The FGID component
and the system should function as normal, with the exception that ltrace will not be available for
fgid_server process.
Recommended Action No action is required.
Error Message
%FABRIC-FGID_SVR-7-ERR_SYSMGR
[chars] ; rc equals [chars]
Explanation The FGID-DB server failed in sysmgr API
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FGID_SVR-7-ERR_SYSMGR
[chars] ; rc equals [chars]
Explanation The FGID-DB server failed in sysmgr API
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FIA Messages
Error Message
%FABRIC-FIA-2-FIAHW_INT_FIFO
[chars] [chars] ([hex])
Explanation This error usually indicates an internal hardware problem on the card. The internal
parity error affects the communication bus between adjacent ASICs on the hardware datapath. The
From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part
of the message.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
atleast 3 minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-2-FIAHW_INT_PARITY
[chars] [chars] ([hex])
Explanation This error usually indicates an internal hardware problem on the card. The internal
parity error affects the communication bus between adjacent ASICs on the hardware datapath. The
From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part
of the message.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
atleast 3 minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-3-ERR_MEM_ALLOC
Memory allocation failed for internal data
structures
Explanation Memory was not available for an internal data structure. The requested operation could
not be accomplished because of a low memory condition. The LC will not boot up successfully and
will not be able to participate in data forwarding.
Recommended Action Run the debug show commands, gather data and contact tac. Also ensure the
LC is populated with the minimum amount of memory required for proper operation. If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-ERR_MEM_ALLOC
Memory allocation failed for internal data
structures
Explanation Memory was not available for an internal data structure. The requested operation could
not be accomplished because of a low memory condition. The LC will not boot up successfully and
will not be able to participate in data forwarding.
Recommended Action Run the debug show commands, gather data and contact tac. Also ensure the
LC is populated with the minimum amount of memory required for proper operation. If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FFIAHW_ERR_FIFO
[chars]: [chars] [hex]
Explanation This error usually indicates an internal hardware problem on the card. The internal
parity error affects the communication bus between adjacent ASICs on the hardware datapath. In
this case parity error was detected in the FFIA internal reassembly memory. This error will trigger
a recovery operation. The LC may not be able to forward data packets and traffic loss may be
observed due to this error.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-3-FFIAHW_ERR_PARITY
[chars]: [chars] [hex]
Explanation This error usually indicates an internal hardware problem on the card. The internal
parity error affects the communication bus between adjacent ASICs on the hardware datapath. In
this case the backpressure signals between FFIA and Tx PSE is having signal integrity issue. This
error will trigger a recovery operation. The LC may not be able to forward data packets and traffic
loss may be observed due to this error.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-3-FIAHW_CHIP
Failed to configure [chars] config value in hardware
Explanation The low level FIA driver was unable to complete its write operation. Possible cause is
harware failure. Error recovery will be triggered for this error. The direction of the failure is
indicated in th emessage.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Look for error reports
about the switch fabric (CSC/SFC.)
Error Message
%FABRIC-FIA-3-FIAHW_CRC16
Too many CRC errors on fabric serial line (from slot
[dec])
Explanation This error indicates a problem in the interface between the card reporting error and the
switch fabric card in the indicated slot. Data corruption is imminent.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, you can try moving the card to another slot. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_CRC16
Too many CRC errors on fabric serial line (from slot
[dec])
Explanation This error indicates a problem in the interface between the card reporting error and the
switch fabric card in the indicated slot. Data corruption is imminent.
Recommended Action Wait several minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, Move the card to another slot. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_DEVCTL
FIA device access (read) failed for [chars]
Explanation The low level fabric interface ASIC driver was unable to complete its hardware access
operation. Hardware configuration may not have been successfully completed. This may result in
traffic loss. The output of the show command may not be valid. The direction of the error is indicated
in the message.
Recommended Action Restart the fiad process on the LC. If the error persists, reload the LC using
'hw-module' command.
Error Message
%FABRIC-FIA-3-FIAHW_EMPTY_DEST_SOFTREQ
[chars] Empty destination software
request error [hex]
Explanation An unexpected error has occurred. This error typically means that a unicast or a
multicast packet was received by the fabric interface ASIC to be forwarded across the switching
fabric without any destination slot set in the header of the data packet. The direction of the error and
the slot are indicated by the parameter in the message.
Recommended Action None, this is a transient error and can be safely ignored. However multiple
occurrences of this error indiactes a software problem. Copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_EXT_FIFO
[chars] [chars] ([hex])
Explanation This error indicates a (possibly temporary) problem in the interface between the card
reporting error and the switch fabric. Either the switch fabric is not able source or drain the data
packets to this LC. This error is traffic affecting. Error recovery will be triggered. The From Fabric
or To Fabric direction, the detailed error string and the slot number are provided as part of the
message.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, you can try moving the card to another slot. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_EXT_PARITY
[chars] [chars] ([hex])
Explanation This error indicates a (possibly temporary) problem in the interface between the card
reporting error and the switch fabric. The error recovery will be triggered and the process should
recover after a reset of the affected ASIC. The From Fabric or To Fabric direction, the detailed error
string and the slot number are provided as part of the message.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, you can try moving the card to another slot. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_INT
Unexpected [chars] interrupt
Explanation An unexpected error has occurred. This error will trigger an error recovery and is traffic
affecting. The direction in which the error occurred is specified as part of the meassage. This error
message indicates a masked interrupt occured, even though its handled by the driver, this error
should not have happened.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)
Error Message
%FABRIC-FIA-3-FIAHW_LOS
Persistent LOS on serial link (from slot [dec])
Explanation This error indicates a problem (Loss of Sync) in the interface between the card reporting
error and the switch fabric card in the indicated slot. This error is traffic affecting. Error recovery is
triggered by this error.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, you can try moving the card to another slot. If the message recurs, copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_LOS
Persistent LOS on serial link (from slot [dec])
Explanation This error indicates a problem (Loss of Sync) in the interface between the card reporting
error and the switch fabric card in the indicated slot. This error is traffic affecting. Error recovery is
triggered by this error.
Recommended Action Wait several minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If
errors persist, Move the card to another slot. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_LOS_CLEAR
LOS cleared on serial link (from slot [dec])
Explanation An earlier reported error (Loss of Sync) is now cleared. Normal operations can resume.
Recommended Action No action is required.
Error Message
%FABRIC-FIA-3-FIAHW_LOS_CLEAR
LOS cleared on serial link (from slot [dec])
Explanation An earlier reported error (Loss of Sync) is now cleared. Normal operations can resume.
Recommended Action No action is required.
Error Message
%FABRIC-FIA-3-FIAHW_MULTI_DEST_SOFTREQ
[chars] Multi destination unicast
software request error [hex]
Explanation An unexpected error has occurred. This error typically means that a unicast data packet
was received by the fabric interface ASIC to be forwarded across the switching fabric with more
than one destination slot. The direction of the error and the slot are indicated by the parameter in the
message.
Recommended Action None, this is a transient error and can be safely ignored. However multiple
occurrences of this error indiactes a software problem. Copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_NOHALT
Unexpected [chars] interrupt without halt
Explanation An unexpected error has occurred. This error will trigger an error recovery procedure &
is traffic affecting. The direction in which the error occurred is specified as part of the meassage.
Recommended Action Wait atleast 3 minutes for the corrective action to occur. Ignore repeats of this
error while corrective action is taking place. Look for error reports about the switch fabric
(CSC/SFC.)
Error Message
%FABRIC-FIA-3-FIAHW_RATE
Error report timer wheel failure detected
Explanation An internal data structure was missing a field. Some errors may not be reported to the
fabric control software. This error indicates data corruption in internal structures.
Recommended Action The system will normally recover from this error without intervention. If the
frequency with which this error is occurring increases substantially, call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_RATE
Error report timer wheel failure detected
Explanation An internal data structure was missing a field. Some errors may not be reported to the
fabric control software. This error indicates data corruption in internal structures.
Recommended Action The system will normally recover from this error without intervention. If the
frequency with which this error is occurring increases substantially, call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_TMR
Forced timeout of an internal timer failed, error [chars]
Explanation The library call failed. This indicates internal data corruption on the LC. Certain errors
may not be reported to the fabric control software. The error string as returned by the library call is
included in the message.
Recommended Action The system will normally recover from this error without intervention. If the
frequency with which this error is occurring increases substantially, call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_TMR
Forced timeout of an internal timer failed, error [chars]
Explanation The library call failed. This indicates internal data corruption on the LC. Certain errors
may not be reported to the fabric control software.
Recommended Action The system will normally recover from this error without intervention. If the
frequency with which this error is occurring increases substantially, call your Cisco technical
support representative and provide the gathered information. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FIA-3-FIAHW_UNHANDLED
Unexpected error case
Explanation An unexpected error has occurred. This error will trigger an error recovery and is traffic
affecting. An error other than the CRC or LOS has occurred.
Recommended Action Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)
Error Message
%FABRIC-FIA-3-FIAHW_UNHANDLED
Unexpected error case
Explanation An unexpected error has occurred. This error will trigger an error recovery and is traffic
affecting.
Recommended Action Wait several minutes for corrective action to occur. Ignore repeats of this error
while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)
Error Message
%FABRIC-FIA-3-TFIAHW_ERR_PACKET
[chars]: [chars] [hex]
Explanation This error usually indicates an internal hardware problem on the card. A corrupted
packet was received from the Rx BMA, this indicates communication bus between the FIA and Rx
BMA on the hardware datapath may have signal integrity issues. This error will trigger an error
recovery. The LC may not be able to forward data packets and traffic loss may be observed due to
this error.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-3-TFIAHW_ERR_PARITY
[chars]: [chars] [hex]
Explanation This error usually indicates an internal hardware problem on the card. The internal
parity error affects the communication bus between adjacent ASICs on the hardware datapath. The
LC may not be able to forward data packets and traffic loss may be observed due to this error. The
From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part
of the message.
Recommended Action If there are other error reports about the switch fabric (CSC/SFC) then wait
several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FIA-4-FIAHW_WARNING_UNSUPPORTED_CARD
Warning: This is an unsupported
SIP-600 card with lower revision Fabric Interface ASIC
Explanation This warning indicates that this is an older version of SIP-600 card which does not have
a supported Fabric Interface ASIC (FIA). As a result, any CSC switch-over, RP fail-over or fabric
card OIR may result in FIA ASIC errors, and the router may experience abnormal behavior.
Recommended Action Replace with a later version of SIP-600.
Error Message
%FABRIC-FIA-6-PCDS_STATS_TIMESTAMP_FAILURE
pcds_get_timestamp failed for fia
stats
Explanation This is a message indicating failed to get timestamp for fia stats.
Recommended Action No action is required.
Error Message
%FABRIC-FIA-6-PCDS_STATS_TIMESTAMP_FAILURE
pcds_get_timestamp failed for
superfish stats
Explanation This is a message indicating failed to get timestamp for superfish stats.
Recommended Action No action is required.
FIFO Messages
Error Message
%FABRIC-FIFO-2-SW_FATAL_ERROR
fatal s/w error encountered - [chars], [chars]
Explanation An unrecoverable fatal s/w error was encountered, which results in severe board
malfunction. The exact cause is appended to the error msg.
Recommended Action Reload the board. *SUPPORT*
FSDB Messages
Error Message
%FABRIC-FSDB-0-BARRIER_STALL_RACK_RELOAD
Rack [dec] reloading due to fabric
barrier stall on the rack. Fabric shutdown log saved in file [chars].
Explanation Rack is brought down if RPs on the rack are detected stalling on fabric barriers. If the
rack is isolated from fabric via CLI, then this is expected. If this message occurs otherwise, it could
be due to a software error or an unexpected hw error.
Recommended Action If fabric links, fabric cards or fabric chassis connecting to the rack are brought
down via CLI, then this is expected. If the problem happens otherwise, Copy the error message
exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-0-BARRIER_STALL_ROUTER_RELOAD
Router reloading due to fabric
barrier stall. Fabric shutdown log saved in file [chars].
Explanation Router is brought down if RPs on the dsc rack are detected stalling on fabric barriers. If
the dsc rack is isolated from fabric via CLI, then this is expected. If this message occurs otherwise,
it could be due to a software error or an unexpeced hw error.
Recommended Action If fabric links, fabric cards or fabric chassis connecting to the dsc rack are
brought down via CLI, then this is expected. If the problem happens otherwise, Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-0-FABRIC_LOSS_LC_RELOAD
[chars] reloading due to loss of fabric
connectivity
Explanation A line-card is reloading after detecting that it has totally lost connectivity to the fabric.
If all the fabric boards are OIR'ed or brought down through CLI, this is expected. If this message
occurs otherwise, it could be due to a software error.
Recommended Action If the fabric planes are brought down or the S3-Sponge links are brought down
intentionally, then this is expected. If the problem happens otherwise, Copy the error message
exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-1-ERR_PLANE_CONFIG
Fabric hardware found at location [chars] is
inconsistent with current configured values : [chars]
Explanation The fabric plane configuration for this multi-chassis system cannot be implemented
with the hardware that has been discovered. This error may cause one or more fabric planes to stay
down which will affect the bringup of the rest of the system. Possible causes could be incorrect
admin plane configuration (ie the configuration states that slot 1 is the first card in a plane whereas
slot 0 really is) or an incorrectly sized fiber module is inserted in a slot.
Recommended Action Check the admin plane configuration to ensure that it corresponds with the
actual physical topology of the system. If this configuration looks correct then contact support,
otherwise correct the configuration and the system should recover.
Error Message
%FABRIC-FSDB-1-FABRIC_UPDOWN
Fabric [chars] for data traffic
Explanation If the fabric is reported down, it means that none of the fabric planes are UP. If the fabric
is not UP, system cannot be used for any data traffic.
Recommended Action Ensure that fabric cards are installed in the system. For multichassis systems
ensure that the fabric racks have booted and the fabric cables are installed. Fabric can come up late
if the fabric rack or fabric cards are booted up late. Wait for more time to see if the fabric comes UP.
For MC systems, check if plane admin config exists on the router. If not, configure the plane admin
config. If condition persists, Copy the error message exactly as it appears on the console or in the
system log, call your Cisco technical support representative and provide the representative with the
gathered information.
Error Message
%FABRIC-FSDB-1-PLANE_UPDOWN
Plane [dec] state changed to [chars]%s; [chars]
Explanation If the plane is reported down other than when administratively brought down, it means
that the sprayer cannot reach *any* destination on the plane. This a symptom of too many other
fabric errors (DESTINATION_UPDOWN) than an error itself. The plane can no longer be used to
send any traffic. If the plane is reported mcast_down, it means that certain fabric destinations are
not reachable on this plane.It is still good for unicast traffic, but for destinations which are reachable
on this plane.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-2-ERR_CONTROL_MSG
Rack [dec] sent illegal fabric control message -
[chars]
Explanation Fabric control software running in another rack has notified a status change that is
impossible or illegal.
Recommended Action This error can be caused by an attempt to use the router with in a fabric
configuration that is not supported. For example, there may be three or more linecard racks that have
dual-rack fabric cards installed. Ensure that the correct racks are installed in the router and that
software displays the correct rack numbers and rack types for each rack. Ensure that the software
fabric configuration is correct. If these steps do not find an error, restart fabric control software on
the rack that produced this message, and on the rack sending the illegal message. 'admin process
restart fsdb_server loc loc'. As restart process is disruptive, save output of all the commands
mentioned in required_info before restarting the process. If problem persists, Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ASERVER_DOWNLOAD
Fabric configuration download [chars]: [chars]
Explanation Fabric control software failed to synchronize configuration details between the
fsdb_server and fsdb_aserver processes. If the affected rack is being added to the system it cannot
be brought into service. If the affected rack is already in service, then it cannot respond to fabric
failures or changes.
Recommended Action No action is necessary. If condition persists, Copy the error message exactly as
it appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_CHKPT
Failed to [chars] checkpoint record: [chars].
Exiting...
Explanation FSDB server encountered an error while updating or accessing its checkpoint
information. The System Manager process (sysmgr) will automatically respawn this process, up to
a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will
trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_CHKPT_INIT
Failed to initialize check point library: [chars].
Exiting...
Explanation FSDB was unable to setup the checkpointing facility to offer high availability
functionality. The System Manager process (sysmgr) will automatically respawn this process, up to
a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will
trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_DEBUG
Failed to setup the debugging services: [chars].
Exiting...
Explanation FSDB was unable to initialize the debugging services. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_DSC
FSDB Server: DSC Error [[chars]]: [chars]
Explanation Fabric Status Database server (FSDB) failed to communicate with the DSC server. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective
RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_ECM_CREATE
Failed to create the event connection manager for
[chars]: [chars]. Exiting...
Explanation FSDB encountered an error while attempting to create an event connection manager for
the specified path. The System Manager process (sysmgr) will automatically respawn this process,
up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr
will trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_ECM_NOTIFY
Failed to install ECM notification hanlder for
[chars] path: [chars]. Exiting...
Explanation FSDB encountered an error while attempting to install an ECM notification handler for
the specified path. The System Manager process (sysmgr) will automatically respawn this process,
up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr
will trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_EVM_CREATE
Failed to create the event manager: [chars].
Exiting...
Explanation FSDB encountered an error while attempting to create an event manager. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC
switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_GET_NODEID
FSDB Server: Failed to [chars]: [chars]
Explanation FSDB server failed to obtain either its node ID or extract rack/slot/instance information
(having obtained the node ID). The System Manager process (sysmgr) will automatically respawn
this process, up to a fixed number of times the error is encountered, to recover. If the problem
continues, sysmgr will trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_INTERNAL
[chars] : [chars]
Explanation An internal error occurred that was expected to succeed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-3-ERR_PARSE_FILE
Parse error in fabric definition file [chars], line
[dec]
Explanation A file describing switch fabric components has errors. Some fabric components cannot
be brought into service.
Recommended Action A failed or incomplete software upgrade could cause this error. It could also be
caused by corruption of an existing definition file. Ensure that the definition file is not damaged. If
the problem persists, re-install the fabric control software.
Error Message
%FABRIC-FSDB-3-ERR_RESYNC_TIMEOUT
Timeout during initial synchronization with
[chars]
Explanation When FSDB starts up it attempts to resynchronise the state with all current entities. This
message indicates that one or more of these entities has not responded within the timeout period.
This could lead to FSDB having an inconsistent view of the fabric, and can potentially cause traffic
loss.
Recommended Action Restarting FSDB process on any racks suffering from traffic loss may help, if
not, restart FSDBs on all racks might resolve the issue. 'admin process restart fsdb_server location
loc' Since 'restart process' is a disruptive operation and all the previous state is lost, all the logs for
the commands mentioned in required_info should be saved. If problem persists, Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_SYSDB
FSDB Server: Sysdb failed to [chars]: [chars]
Explanation FSDB encountered a Sysdb communication failure. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_SYSDB_BIND
Connection to the sysdb server failed: [chars]
Explanation FSDB failed to open a connection to the Sysdb Server process for one of the paths. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective
RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_SYSDB_EDM_NOTIF_GEN
FSDB Server: Failed generating [chars]
notification: [chars]
Explanation FSDB external data manager failed to generate a trap notification. Process would
continue to run normally.
Recommended Action This message indicate that trap notifications of the operational states of planes
and bundles would not occur. If snmp managability is not enabled, this message can be ignored.
However, if this functionality is necessary then restart the process by issuing the following command
at the CLI of the active RP after collecting all the output of all the specified commands. 'admin
process restart fsdb_server/fsdb_aserver loc loc' Restart fsdb_server if the bundle state traps are
missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as
it appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_SYSDB_EDM_REG
Failed to register as an EDM for [chars]:
[chars], exiting...
Explanation The FSDB was unable to become an external data manager (EDM) for the specified
path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed
number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger
respective RP/SC switchover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_SYSDB_REG_NOTIF
FSDB Server: Failed to register notification
for [chars] path: [chars]. SNMP traps will not be generated for this path
Explanation FSDB external data manager failed to register for notifications for the specified path.
Process would continue to run normally, except that SNMP traps will not be generated for changes
in fabric state.
Recommended Action This message indicate that trap notifications of the operational states of planes
and bundles would not occur. If snmp managability is not enabled, this message can be ignored.
However, if this functionality is necessary then restart the process by issuing the following command
at the CLI of the active RP after collecting all the output of all the specified commands. 'admin
process restart fsdb_server/fsdb_aserver loc loc' Restart fsdb_server if the bundle state traps are
missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as
it appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-FSDB-3-ERR_UNKNOWN_FAB_DEF
Cannot find fabric definition file [chars]
Explanation A file describing switch fabric components is not present on the router.
Recommended Action If the hardware installed in the router has changed, ensure that fabric control
software has been upgraded to the correct version. If the correct software has been installed, report
the problem to technical support.
Error Message
%FABRIC-FSDB-4-ERR_FLED
[chars] : [chars], LED(Row [dec], col [dec]),
corresponding to node [dec]
Explanation Fabric LED internal software error occurred. It is possible to continue operation,
although some LEDs on fabric led board may incorrectly illuminate. However, if this functionality
is necessary then restart the process by issuing the following command at the CLI of the active RP
after collecting all the output of all the specified commands. 'admin process restart fsdb_server loc
loc' *SUPPORT*
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-ERR_INTERNAL_WARN
[chars] : [chars]
Explanation FSDB encountered a minor internal software error. It is possible that fabric operates
normally without any issues.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-ERR_THREAD_COND_SIGNAL
Failed thread conditional signal on
[chars]: [chars].
Explanation FSDB encountered an error while attempting to signal a thread conditionally. The
operation related to the resource will be affected and the process will continue to run normally.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-ERR_THREAD_COND_WAIT
Failed thread conditional wait on [chars]:
[chars].
Explanation FSDB encountered an error while attempting to wait conditionally on a thread. The
operation related to the resource will be affected and the process will continue to run normally.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-ERR_THREAD_MUTEX_LOCK
Failed to lock [chars] mutex : [chars].
Explanation FSDB encountered an error while locking a mutex to access the specified shared
resource. The operation related to the resource may be affected while the process continues to run
normally.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-ERR_THREAD_MUTEX_UNLOCK
Failed to unlock [chars] mutex : [chars].
Explanation FSDB encountered an error while locking unlocking a mutex to access the specified
shared resource. The operation related to the resource may be affected while the process continues
to run normally.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSDB-4-PLANE_SHUTDOWN
It is advisable to have [chars] to be up. Shutting
down all the planes will leave the router in unrecoverable state.
Explanation In a CRS-16 system, at least one odd plane and at least one even plane is required. In
others, at least one plane is required. If all the planes are shutdown, the router goes into an
unrecoverable state.
Recommended Action Try to unshut a plane. If it doesnt help, the only way out is to reload the router
either from the CLI or powercycle.
Error Message
%FABRIC-FSDB-7-ERR_MEM_ALLOC
Failed to allocate memory.
Explanation FSDB has failed to allocate memory for its resources. This would affect proper
functioning of fabric.
Recommended Action This indicates a low-memory condition. Reduce other system activity to ease
memory demands. If conditions warrant, upgrade to a larger memory configuration.
Error Message
%FABRIC-FSDB-7-ERR_SYSDB_BAG_ENCODE
FSDB Server: SYSDB Bag encode[[chars]]:
[chars]
Explanation FSDB server encountered error in sysdb bag encode operation. This could affect output
of some of the fabric CLI commands.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
FSTATSA Messages
Error Message
%FABRIC-FSTATSA-3-ERR_BAG_REG
Bag register error is detected; [chars].
Explanation Fabric statistics aggregator process encountered a fatal error to register its bags to bag
software. This software error will cause process termination for recovery The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_BAG_REG
Bag register error is detected; [chars].
Explanation Fabric statistics aggregator process encountered a fatal error to register its bags to bag
software. This software error will cause process termination for recovery The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/server/[chars] event failed; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to initialize debug facility
and hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/server/[chars] event failed; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to initialize debug facility
and hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_DEBUG_REGISTER
Debug registration for fabric statistics
server failed; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to register debug facility
and hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_DEBUG_REGISTER
Debug registration for fabric statistics
server failed; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to register debug facility
and hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_EVM_CREATE
Failed to create event manager; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to create its event manager
for receiving events. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_EVM_CREATE
Failed to create event manager; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to create its event manager
for receiving events. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars]; rc equals [hex].
Explanation Fabric statistics aggregator process encountered a fatal error to create group for group
communication. This software error will cause process termination to recover. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars]; rc equals [hex].
Explanation Fabric statistics aggregator process encountered a fatal error to create group for group
communication. This software error will cause process termination to recover. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_INTERNAL
Internal software error: [chars]; [chars]
Explanation Fabric statistics aggregator process encountered a fatal internal software error. This
software error will cause process termination to recover. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. *RECUR*
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_INTERNAL
Internal software error: [chars]; [chars]
Explanation Fabric statistics aggregator process encountered a fatal internal software error. This
software error will cause process termination to recover. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. *RECUR*
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSDB_BIND
Can't bind to SysDB at [chars]; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to bind to admin plane
sysdb server. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSDB_BIND
Can't bind to SysDB at [chars]; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to bind to admin plane
sysdb server. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSDB_EDM_REG
Failed to register SysDB EDM at [chars];
[chars]
Explanation Fabric statistics aggregator process encountered a fatal error to register EDM to admin
plane sysdb server. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSDB_EDM_REG
Failed to register SysDB EDM at [chars];
[chars]
Explanation Fabric statistics aggregator process encountered a fatal error to register EDM to admin
plane sysdb server. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSMGR_PROC_READY
Failed to report process ready to
sysmgr; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to report process ready to
sysmgr. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSA-3-ERR_SYSMGR_PROC_READY
Failed to report process ready to
sysmgr; [chars]
Explanation Fabric statistics aggregator process encountered a fatal error to report process ready to
sysmgr. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
FSTATSC Messages
Error Message
%FABRIC-FSTATSC-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars].
Explanation Fabric statistics client library encountered failure of creating group for GSP group
communication.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars].
Explanation Fabric statistics client library encountered failure of creating group for GSP group
communication.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_CLEANUP
Debug cleanup for fabric statistics client
library failed: [chars]
Explanation Fabric statistics client library encountered debug facility clean up failure.
Recommended Action None.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_CLEANUP
Debug cleanup for fabric statistics client
library failed: [chars]
Explanation Fabric statistics client library encountered debug facility clean up failure.
Recommended Action None.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/client/[chars] event failed: [chars]
Explanation Fabric statistics client library encountered debug facility initialization failure. When
this error happens, the library will not able to enable debug.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/client/[chars] event failed: [chars]
Explanation Fabric statistics client library encountered debug facility initialization failure. When
this error happens, the library will not able to enable debug.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_REG
Debug registration for fabric statistics client
library failed: [chars]
Explanation Fabric statistics client library encountered debug facility registration failure. When this
error happens, the library will not able to enable debug.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-7-ERR_DEBUG_REG
Debug registration for fabric statistics client
library failed: [chars]
Explanation Fabric statistics client library encountered debug facility registration failure. When this
error happens, the library will not able to enable debug.
Recommended Action Restart Fabric statistics client manually if the error is persistent.
Error Message
%FABRIC-FSTATSC-7-ERR_GSP_LOOKUP_LWG
GSP lightweight group [chars] lookup was
failed; [chars].
Explanation Fabric statistics client library encountered failure when it looks up Fabric server light
weight group for light weight group communication. Normally, this is a transient error. It can be a
true error if the error is persistent.
Recommended Action Restart Fabric statistics client manually if the error is persistent in a specific
fabric card. Restart Fabric statistics server manually if the error is persistent in many fabric cards.
Error Message
%FABRIC-FSTATSC-7-ERR_GSP_LOOKUP_LWG
GSP lightweight group [chars] lookup was
failed; [chars].
Explanation Fabric statistics client library encountered failure when it looks up Fabric server light
weight group for light weight group communication. Normally, this is a transient error. It can be a
true error if the error is persistent.
Recommended Action Restart Fabric statistics client manually if the error is persistent in a specific
fabric card. Restart Fabric statistics server manually if the error is persistent in many fabric cards.
FSTATSS Messages
Error Message
%FABRIC-FSTATSS-3-ERR_BAG_REG
Bag register error is detected; [chars].
Explanation Fabric statistics server process encountered a fatal error to register its bags to bag
software. This software error will cause process termination for recovery The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_BAG_REG
Bag register error is detected; [chars].
Explanation Fabric statistics server process encountered a fatal error to register its bags to bag
software. This software error will cause process termination for recovery The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/server/[chars] event failed; [chars]
Explanation Fabric statistics server process encountered a fatal error to initialize debug facility and
hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_DEBUG_INIT_EVENT
Debug initialization for the
fstats/server/[chars] event failed; [chars]
Explanation Fabric statistics server process encountered a fatal error to initialize debug facility and
hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_DEBUG_REGISTER
Debug registration for fabric statistics
server failed; [chars]
Explanation Fabric statistics server process encountered a fatal error to register debug facility and
hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_DEBUG_REGISTER
Debug registration for fabric statistics
server failed; [chars]
Explanation Fabric statistics server process encountered a fatal error to register debug facility and
hence failed to initialize. This software error will cause process termination for recovery. The
System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of
times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload.
After a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_EVM_CREATE
Failed to create event manager; [chars]
Explanation Fabric statistics server process encountered a fatal error to create its event manager for
receiving events. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_EVM_CREATE
Failed to create event manager; [chars]
Explanation Fabric statistics server process encountered a fatal error to create its event manager for
receiving events. This software error will cause process termination for recovery. The System
Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times
the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After
a certain number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars]; rc equals [hex].
Explanation Fabric statistics server process encountered a fatal error to create group for group
communication. This software error will cause process termination to recover. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_GSP_GROUP_CREATE
GSP group [chars] creation/join was
failed; [chars]; rc equals [hex].
Explanation Fabric statistics server process encountered a fatal error to create group for group
communication. This software error will cause process termination to recover. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_INTERNAL
Internal software error: [chars]; [chars]
Explanation Fabric statistics server process encountered a fatal internal software error. This software
error will cause process termination to recover. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node
reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_INTERNAL
Internal software error: [chars]; [chars]
Explanation Fabric statistics server process encountered a fatal internal software error. This software
error will cause process termination to recover. The System Manager process (sysmgr) will
automatically respawn this process, up to a fixed number of times the error is encountered, to
recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node
reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_MEM_ALLOC
Could not allocate memory for [chars].
Explanation Fabric statistics server process encountered memory allocation error for creating
statistics database or storing statistics data. This software error will cause process termination to
recover during process initialization. The System Manager process (sysmgr) will automatically
respawn this process, up to a fixed number of times the error is encountered, to recover. If the
problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf
manager will permanently shutdown the node.
Recommended Action Memory allocation failures will happen if the the router runs out of memory or
memory leak in this process or other processes. User needs to do 'process restart memory hog
process job id' to recover.
Error Message
%FABRIC-FSTATSS-3-ERR_MEM_ALLOC
Could not allocate memory for [chars].
Explanation Fabric statistics server process encountered memory allocation error for creating
statistics database or storing statistics data. This software error will cause process termination to
recover during process initialization. The System Manager process (sysmgr) will automatically
respawn this process, up to a fixed number of times the error is encountered, to recover. If the
problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf
manager will permanently shutdown the node.
Recommended Action Memory allocation failures will happen if the the router runs out of memory or
memory leak in this process or other processes. User needs to do 'process restart memory hog
process job id' to recover.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSDB_BIND
Can't bind to SysDB at [chars]: [chars]
Explanation Fabric statistics server process encountered a fatal error to bind to admin plane sysdb
server. This software error will cause process termination for recovery. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSDB_BIND
Can't bind to SysDB at [chars]: [chars]
Explanation Fabric statistics server process encountered a fatal error to bind to admin plane sysdb
server. This software error will cause process termination for recovery. The System Manager process
(sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSDB_EDM_REG
Failed to register SysDB EDM at at [chars]:
[chars]
Explanation Fabric statistics server process encountered a fatal error to register EDM to admin plane
sysdb server. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSDB_EDM_REG
Failed to register SysDB EDM at at [chars]:
[chars]
Explanation Fabric statistics server process encountered a fatal error to register EDM to admin plane
sysdb server. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSMGR_PROC_READY
Failed to report process ready to
sysmgr; [chars]
Explanation Fabric statistics server process encountered a fatal error to report process ready to
sysmgr. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-3-ERR_SYSMGR_PROC_READY
Failed to report process ready to
sysmgr; [chars]
Explanation Fabric statistics server process encountered a fatal error to report process ready to
sysmgr. This software error will cause process termination for recovery. The System Manager
process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is
encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain
number of node reloads, the shelf manager will permanently shutdown the node.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-FSTATSS-7-ERR_RSC_REG_INCONSISTENT_VALUE
[chars]: fabric resource
registration error due to inconsistent value.
Explanation Fabric statistics server process encountered a transient error due to the inconsistent
checking of the received message. This error message will be a true error if many error message is
logged and the error is persistent.
Recommended Action If the error continues, user will need to restart the process for recovery.
Error Message
%FABRIC-FSTATSS-7-ERR_RSC_REG_INCONSISTENT_VALUE
[chars]: fabric resource
registration error due to inconsistent value.
Explanation Fabric statistics server process encountered a transient error due to the inconsistent
checking of the received message. This error message will be a true error if many error message is
logged and the error is persistent.
Recommended Action If the error continues, user will need to restart the process for recovery.
INGRESSQ_ALARM Messages
Error Message
%FABRIC-INGRESSQ_ALARM-2-DEVICE_HALT
INGRESSQ: device halted, sub-block:
[chars], halted entity: [chars]
Explanation INGRESSQ, ASIC got halted. The halted block and its parent block are provided
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_ALARM-2-DEVICE_HALT
INGRESSQ: device halted, sub-block:
[chars], halted entity: [chars]
Explanation INGRESSQ, ASIC got halted. The halted block and its parent block are provided
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
INGRESSQ_DLL Messages
Error Message
%FABRIC-INGRESSQ_DLL-2-ASIC_RESET_FAILED
Ingressq ASIC reset failed. Bringing
the MSC down.
Explanation Ingressq, ASIC reset failed and it could be due to several reasons.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-2-ERR_EIO_TRAIN
EIO link training threshold exceeded, link:
[dec]
Explanation Ingressq DLL encountered a fatal error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-2-ERR_EIO_TRAIN
EIO link training threshold exceeded, link:
[dec]
Explanation Repeated attempts to train the EIO links to the neighboring Asic have failed. No further
attempts to retrain the link will be made.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-2-TAKING_NODE_DOWN
Taking the node down, Reason: [chars]
Explanation Ingressq DLL encountered a fatal error and taking the node down.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-2-TAKING_NODE_DOWN
Taking the node down, Reason: [chars]
Explanation Ingressq DLL encountered an fatal error mentioned above. The driver triggers MSC
node-down to recover from the error.
Recommended Action This might be a recovery action from a fault. If the message recurs, copy the
error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-BRM_BARRIER_SYNCUP_FAILED
BRM BlocK: Barrier sync up
failed for this node.
Explanation There might be a fabric disconnect in the system.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_FCRAM_ASSERT
Assert Error valid: [dec], block:
[dec], debug_info: [dec]
Explanation Ingressq encountered an assert error indicated.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_FCRAM_ASSERT
Assert Error valid: [dec], block:
[dec], debug_info: [dec]
Explanation Ingressq encountered an assert error in the FCRAM. The driver triggers a device reset.
The device should be reinitialized.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_MBE
Multiple Bit Error in Block: [chars] Error:
[chars] at Memory Address [hex].
Explanation Ingressq encountered a multiple bit error in the mentioned block. This error is an
uncorrectable error.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_MBE
Multiple Bit Error in Block: [chars] Error:
[chars] at Memory Address [hex].
Explanation Ingressq encountered a multiple bit error in the mentioned block. This error is an
uncorrectable error. Driver takes appropriate action to log and fix the error which may include a
device reset.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_BIST
Error during [chars] BIST
Explanation Ingressq BIST error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_BIST
Error during [chars] BIST
Explanation BIST failed for the mentioned block. The driver should trigger a device reset to fix this
error.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_INIT
[chars]
Explanation The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq
driver process.
Recommended Action Collect all the event logs and the output of the following command executed
from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: 'show
fabric-snapshot file loc '
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_INIT
[chars]
Explanation Ingressq dll manager encountered an fatal error and is not able recover from the error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_MEM_ALLOC
Error Allocating memory for [chars]
Explanation The Ingressq dll Memory Allocation Error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-ERR_MEM_ALLOC
Error Allocating memory for [chars]
Explanation The Ingressq dll Memory Allocation Error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-RESET
Resetting IQM ASIC Device
Explanation Reseting IQM ASIC on detecting fatal error.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-RESET
Resetting IQM ASIC Device
Explanation Ingressq, cpuctrl net interface encountered a CRC/Sync Error. This will result in the
PIO or CDMA failure.
Recommended Action If it is possible to isolate the trigger point for the sn link error, collect all the
necessary condition that caused the error. If the message recurs, copy the error message exactly as
it appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_POST_OP_FAILED
Sequencer state: [dec], reason:
[chars] : [chars], #retries: [dec]
Explanation Ingressq driver state machine encountered a failure in initializing the device above
threshold number of times. Driver will continue to initialize the device.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_POST_OP_FAILED
Post OP Failed: sequencer state:
[dec], reason: [chars] : [chars], #retries: [dec]
Explanation Sprayer sequencer post op failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_PRE_OP_FAILED
Pre OP Failed - Exiting :
sequencer state: [dec], reason: [chars] : [chars]
Explanation Sprayer sequencer pre op failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_PRE_OP_FAILED
Exiting. sequencer state: [dec],
reason: [chars] : [chars]
Explanation Ingressq driver state machine encountered an unrecoverable error. This will result in
driver restart.
Recommended Action The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq
driver is up and running by executing the following command at the CLI of the active RP: 'show
process ingressq location ' If it is still non-operational, enable the following debugs of the ingressq
driver process: asic error asic fatal asic info and restart the driver by executing the following
command at the CLI of the active RP: 'process restart ingressq location ' If the message recurs, copy
the error message exactly as it appears on the console or in the system log, call your Cisco technical
support representative and provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-3-WDG_SEG_HUNG
Spiller Seg blk is hung, reseting spiller -
pkt_fifo [hex], ctrl_fifo [hex], icf_fifo [hex]
Explanation Watchdog detected that spiller seg block is hung, reseting spiller to recover
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-3-WDG_SEG_HUNG
Spiller Seg blk is hung, reseting spiller -
pkt_fifo [hex], ctrl_fifo [hex], icf_fifo [hex]
Explanation Watchdog detected that spiller seg block is hung, reseting spiller to recover
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_AGGR_DELTA_THRSHLD
BRM aggr delta, spo link: [dec],
cast: [dec], threshold: [unsigned long int]
Explanation There might be a fabric disconnect in the system.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_AGGR_DELTA_THRSHLD
BRM aggr delta, spo link: [dec],
cast: [dec], threshold: [dec]
Explanation Hardware halt is not handled.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_DELTA_THRSHLD
BRM delta threshold, spo link: [dec],
cast: [dec], threshold: [unsigned long int]
Explanation There might be a fabric disconnect in the system.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_DELTA_THRSHLD
BRM delta threshold, spo link: [dec],
cast: [dec], threshold: [dec]
Explanation Hardware halt is not handled.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_DID_CULPRIT
BRM double in delta culprit, spo link:
[dec], cast: [dec]
Explanation There might be a fabric disconnect in the system.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_DID_CULPRIT
BRM double in delta culprit, spo link:
[dec], cast: [dec]
Explanation Hardware halt is not handled.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_INVALID_INPUT
BRM invalid input; spo: [dec], cast:
[dec], input_barr: [hex], current_barr: [hex]
Explanation Invalid input on a link
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_INVALID_INPUT
BRM invalid input; spo: [dec], cast:
[dec], current_barr: [hex] input_barr: [hex]
Explanation There might be a fabric disconnect in the system.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_PHASE_CHANGE_COUNTER
BRM, phase didn't change, spo
link: [dec], cast: [dec], phase: [hex], phase to counter: [hex], phase to thr:
[hex]
Explanation Barrier Manager encountered a phase change error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-BRM_PHASE_CHANGE_COUNTER
BRM, phase didn't change, spo
link: [dec], cast: [dec], phase: [hex], phase to counter: [hex], phase to thr:
[hex]
Explanation Barrier Manager encountered a phase change error.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-CDMA_REQ_ERROR
CpuCtrl error, addr:([hex],[hex]), dir:
[dec], rc: [dec]
Explanation cpuctrl driver was not able to complete the CDMA request.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-CDMA_REQ_ERROR
CpuCtrl error, addr:([hex],[hex]), dir:
[dec], rc: [dec]
Explanation CpuCtrl driver was not able to complete the CDMA request for the above specified
address location. This may be caused if the device is not initialized correctly or synchronized
correctly.
Recommended Action If it is possible to isolate the trigger point for the cdma failure, collect all the
necessary condition that caused the error. Copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_CRC
CRC Error: Block:[chars] Error:[chars]
Count: [dec]
Explanation Ingressq block received a packet with a CRC error. It is primarily caused by either the
link errors between the devices or packet corruption in the upstream asic. This error may cause
performance degradation.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_CRC
Block: [chars], entity: [chars] had CRC
error(s), count: [dec]
Explanation PII block got a packet from the entity mentioned above with a CRC error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_LENGTH
Block: [chars], entity: [chars] has
length error(s), expected: [dec], received: [dec]
Explanation PII block got a packet from the entity mentioned above with a length error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_LENGTH
Block: [chars] encountered error:
[chars]. It received a packet with length error(s), expected: [dec], received:
[dec]
Explanation Ingressq received a packet with incorrect length either from cpuctrl or Ingress PSE. It
is primarily caused by either the link errors between the devices or packet corruption in the upstream
asic.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_SN_LINK
CpuCtrl Interface RxFIFO Error: [chars]
Explanation Ingressq, cpuctrl net interface Rx FIFO last sync.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_SN_LINK
CpuCtrl Interface RxFIFO Error: [chars]
Explanation Ingressq, cpuctrl net interface Rx FIFO last sync.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INIT
Error encountered during Checkpoint
Initialization
Explanation Ingressq Checkpoint Init error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INIT
Error encountered during Checkpoint
Initialization
Explanation Ingressq Checkpoint Init error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INSERT
Error encountered during [chars]
Checkpoint Insertion
Explanation Ingressq Checkpoint Insert error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INSERT
Error encountered during [chars]
Checkpoint Insertion
Explanation Ingressq Checkpoint Insert error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-INTR_ENABLE_FAIL
Interrupt enable at addr: [hex] mask:
[hex] failed.
Explanation hardware state is not correct.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-4-INTR_ENABLE_FAIL
Interrupt enable at addr: [hex] mask:
[hex] failed.
Explanation Hardware state is not correct.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-LNS_CCDF_OVERFLOW_ERROR
control cell fifo overflow error
Explanation Ingressq LNS control cell fifo overflow.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-LNS_CCDF_OVERFLOW_ERROR
control cell fifo overflow error
Explanation Ingressq LNS control cell fifo overflow.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-LNS_LOP_DROP
low availability of planes, aggr cell drop
count: [unsigned long long int]
Explanation Ingressq LNS dropped cells because of low availability of planes.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-LNS_LOP_DROP
Error: Cells dropped due to low availability
of planes, aggr cell drop count: [unsigned long long int]
Explanation Ingressq dropped a few cells because of unavailability of enough planes to forward the
cells to its destination. If the cells are dropped intermittently during system reconfiguration (LC
reload, RP fail over, etc), then these drops are expected. System will recover after the hardware
reprogramming completes. If these drops are seen continuously for long periods, then this indicates
that either the node is not programmed correctly, or there is an error in data plane software.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-4-PFI_PARITY_ERROR
parity error in plane RA, name: [chars],
link: [dec], RA: [dec], Addr: [dec]
Explanation Ingressq, cpuctrl net interface Rx FIFO last sync.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-4-PFI_PARITY_ERROR
parity error in plane RA, name: [chars],
link: [dec], RA: [dec], Addr: [dec]
Explanation Ingressq, cpuctrl net interface Rx FIFO last sync.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_PARITY
Block: [chars], entity: [chars] had
parity error(s), addr: [dec], parity: [dec]
Explanation One of the Ingressq blocks had a parity error.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_PARITY
Block: [chars], entity: [chars] had
parity error(s), addr: [dec], parity: [dec]
Explanation In the specified block a parity error encountered at mentioned addr offset. If the error
exceeds its threshold, the driver trigger a corrective action which may include device reset or MSC
reload.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_SBE
Single Bit Error in Block: [chars] Error:
[chars] at Memory Address: [hex]
Explanation Ingressq encountered a single bit error in the mentioned block. Persistent errors are
corrected by the software. Non-persistent errors are automatically corrected when the memory
location is eventually overwritten.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_SBE
Single Bit Error in Block: [chars] Error:
[chars] at Memory Address: [hex]
Explanation Ingressq encountered a single bit error in the mentioned block. Persistent errors are
corrected by the software. Non-persistent errors are automatically corrected by the next write
operation.
Recommended Action This error is an correctable error. There are no side effects. If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-6-BRM_BARRIER_SYNCED_UP
BRM Block: Barrier synced up on
this node.
Explanation This message indicates that system barriers synced on this node. This message is
expected during normal operation.
Recommended Action No action is required.
Error Message
%FABRIC-INGRESSQ_DLL-6-BRM_BARRIER_SYNCUP_FAILED
BRM BlocK: Barrier sync up
failed for this node.
Explanation Ingressq, Barrier is not synced up.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_GENERIC
Block: [chars], Generic Error [chars] at
Memory Address [hex].
Explanation Ingressq encountered an interrupt that has exceeded its threshold value. Software takes
appropriate action to log and fix the error.
Recommended Action No action is required.
Error Message
%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_GENERIC
Block: [chars], Generic Error [chars] at
Memory Address [hex].
Explanation Ingressq encountered a device error that has exceeded its threshold value. Driver takes
appropriate action to log and fix the error which may include a device reset.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_OOR
Block: [chars], entity: [chars] had Out Of
Resources error(s), count: [dec]
Explanation Ingressq block is unable to get packet memory from FQM.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_OOR
Block: [chars], entity: [chars] had Out Of
Resources error(s), count: [dec]
Explanation Ingressq block is unable to get packet memory for the incoming packets. This condition
is caused by over subscription or hitting the Packet Per Second rate. This will affect the QOS. Thus
it is recommended to reduce the packet rate to this MSC.
Recommended Action Reduce the incoming packet rate to this MSC as under the OOR condition the
QOS If the OOR is seen in non-oversubscribed case, contact TAC Reduce other system activity to
ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-6-SEQ_STATE_THRESHOLD_EXCEEDED
sequencer state: [dec],
threshold: [dec], reason: [chars], #retries: [dec]
Explanation Ingressq sequencer state threshold exceeded.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-SEQ_STATE_THRESHOLD_EXCEEDED
sequencer state: [dec],
threshold: [dec], reason: [chars], #retries: [dec]
Explanation Ingressq sequencer state threshold exceeded.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALL_CLEARED
[chars]: barrier stall cleared.
Explanation Ingressq, Barrier stall cleared on one of the casts
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALL_CLEARED
[chars]: barrier stall cleared.
Explanation Ingressq, Barrier stall cleared on one of the casts
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALLED
[chars]: barrier stalled.
Explanation Ingressq, Barrier stalled on one of the casts
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALLED
[chars]: barrier stalled.
Explanation Ingressq, Barrier stalled on one of the casts
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-7-ERR_REGISTER_GET
Register get failed for address [hex],
Reason: [chars]
Explanation Hardware register read failed.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant,
upgrade to a larger memory configuration.
Error Message
%FABRIC-INGRESSQ_DLL-7-ERR_REGISTER_GET
Register get failed for address [hex],
Reason: [chars]
Explanation An attempt to read a Hardware register failed. This could result in inconsistent behavior
of the device.
Recommended Action Run diags on the board and contact TAC support. If it is possible to isolate the
trigger point for the read failure, collect all the necessary condition that caused the error. If the
message recurs, copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_DLL-7-ERR_RES_PROG
Error during Resource Programming: [chars]
Reason: [chars]
Explanation Ingressq encountered an error during resource programming. If there are no further
attempts to reprogram the device, the device behavior may be inconsistent.
Recommended Action The driver/client processes try to recover from this error. Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ_DLL-7-ERR_RES_PROG
Error during Resource Programming: [chars]
Reason: [chars]
Explanation Ingressq encountered an error during resource programming.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
INGRESSQ_LIB Messages
Error Message
%FABRIC-INGRESSQ_LIB-7-ERR_LWM_SEND
Ingressq Lib: LWM Message send failed msg:
[dec], retried: [dec] time(s), errno: [chars]
Explanation Unable to send a LWM message to the Ingressq server.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ_LIB-7-ERR_LWM_SEND
Ingressq Lib: LWM Message send failed msg:
[dec], retried: [dec] time(s), errno: [chars]
Explanation Unable to send a LWM message to the Ingressq server.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
INGRESSQ Messages
Error Message
%FABRIC-INGRESSQ-2-ASIC_RESET_FAILED
Ingressq: Error encountered during hw reset
of sprayer.
Explanation Ingressq hw reset error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-2-ASIC_RESET_FAILED
Ingressq: Error encountered during hw reset
of sprayer.
Explanation Ingressq hw reset error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-3-ERR_INIT
Fatal error encountered, reason equals [chars]
Explanation The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq
driver process.
Recommended Action Collect all the event logs and the output of the following command executed
from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: show
fabric-snapshot file loc
Error Message
%FABRIC-INGRESSQ-3-ERR_INIT
Fatal error encountered, reason equals [chars]
Explanation Ingressq encountered a fatal unrecoverable error. This process is mandatory and it will
restart itself.
Recommended Action Ingressq Process will restart itself and recover from the error if possible.
Otherwise, after fixed number of retries, sysmgr will bring the MSC down.
Error Message
%FABRIC-INGRESSQ-3-ERR_MEM_ALLOC
Error Allocating [dec] bytes of memory
Explanation Ingressq encountered a fatal memory allocation error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-3-ERR_MEM_ALLOC
Error Allocating [dec] bytes of memory
Explanation Ingressq encountered a fatal memory allocation error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-4-ERR_CHKPT_INIT
Ingressq Dll: Error encountered during
Checkpoint Init. Exiting
Explanation Ingressq Checkpoint Init error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-4-ERR_CHKPT_INIT
Error encountered during Checkpoint Init.
Exiting
Explanation Ingressq Checkpoint Init error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_BAG_REG
ingressq: bag register failed for rules
Explanation EDM Bags are used to share information between components using sysdb. This Error
indicates that bag registration failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_BAG_REG
Bag register failed for rules
Explanation EDM Bags are used to share information between components using sysdb. This Error
indicates that bag registration failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CHKPT_DELETE
Error encountered during [chars] Checkpoint
Deletion
Explanation Ingressq Checkpoint delete error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CHKPT_DELETE
Error encountered during [chars] Checkpoint
Deletion
Explanation Ingressq Checkpoint delete error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CHKPT_INSERT
Error encountered during [chars] Checkpoint
Insertion
Explanation Ingressq Checkpoint Insert error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CHKPT_INSERT
Error encountered during [chars] Checkpoint
Insertion
Explanation Ingressq Checkpoint Insert error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CLIENT_REG
Client [chars] failed. Error: [chars]
Explanation Ingressq client failed to Register/Unregister with Ingressq Server process. This error is
also detected from the client's side. Retrial attempts would be made by the client.
Recommended Action 1. Verify the connectivity between the client and the Ingressq process. 'show
controllers ingressq clients location ' Copy the error message exactly as it appears on the console or
in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%FABRIC-INGRESSQ-7-ERR_CLIENT_REG
Client [chars] failed. Error: [chars]
Explanation Ingressq client Registration/Unregistration error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_DLL_REG
Dll registration for [chars] failed
Explanation Ingressq driver tried to register for a dll but it encountered an error. The driver might
lose some of its functionality.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_DLL_REG
Dll registration for [chars] failed
Explanation Ingressq driver tried to register for a dll but it encountered an error. The driver might
lose some of its functionality.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_EVM_CREATE
Event Manager create failed for [chars]
Explanation Ingressq Event Manager create error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_EVM_CREATE
Event Manager create failed for [chars]
Explanation Ingressq Event Manager create error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_EVM_NOTIFY
Event Manager notify failed for [chars]
Explanation Ingressq Event Manager notify error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_EVM_NOTIFY
Event Manager notify failed for [chars]
Explanation Ingressq Event Manager notify error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_CREATE
Event Manager create failed
Explanation Ingressq Event Manager create error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_CREATE
Event Manager create failed
Explanation Ingressq Event Manager create error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_EVENT_BLOCK
LWM Event Manager event block failed
Explanation Ingressq Event Manager event block error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_EVENT_BLOCK
LWM Event Manager event block failed
Explanation Ingressq Event Manager event block error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_REPLY
An Error occurred during LWM message reply.
Reason: [chars]
Explanation Ingressq LWM reply error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_LWM_REPLY
An Error occurred during LWM message reply.
Reason: [chars]
Explanation Ingressq LWM reply error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_RES_PROG
Error during Resource Programming: [chars]
Reason: [chars]
Explanation Ingressq encountered an error during resource programming. If there are no further
attempts to reprogram the device, the device behavior may be inconsistent.
Recommended Action The driver/client processes try to recover from this error. If any discrepancies
are found in the device functionality, contact TAC Support. Copy the error message exactly as it
appears on the console or in the system log, call your Cisco technical support representative and
provide the representative with the gathered information.
Error Message
%FABRIC-INGRESSQ-7-ERR_RES_PROG
Error during Resource Programming: [chars]
Reason: [chars]
Explanation Ingressq encountered an error during resource programming.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_BIND
Sysdb Bind failed.
Explanation Ingressq Sysdb Bind error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_BIND
Sysdb Bind failed.
Explanation Ingressq Sysdb Bind error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_EDM_REG
Sysdb Register EDM failed.
Explanation Ingressq Sysdb Register EDM error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_EDM_REG
Sysdb Register EDM failed.
Explanation Ingressq Sysdb Register EDM error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_REG_VERIFY
Sysdb Registration verification failed.
Explanation Ingressq Sysdb Registration verification error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_REG_VERIFY
Sysdb Registration verification failed.
Explanation Ingressq Sysdb Registration verification error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_SET
Sysdb Item Set Failed : [chars]
Explanation Ingressq Sysdb Set error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%FABRIC-INGRESSQ-7-ERR_SYSDB_SET
Sysdb Item Set Failed : [chars]
Explanation Ingressq Sysdb Set error
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the gathered
information.