Layer 1 Messages
This section contains all Layer 1 related System Error Messages. The following facility codes are represented in this module:
•
PLIM_CLKSEL Messages
•
PLIM_LIB Messages
•
PLIM_OC3 Messages
•
PMENGINE Messages
•
SPA_OC3_OC12 Messages
•
SPA_OC48 Messages
•
TREX_LIB Messages
•
TREX Messages
•
UT2 Messages
•
XENA Messages
PLIM_CLKSEL Messages
Error Message
%L1-PLIM_CLKSEL-3-ERR_INIT
PLIM process is restarted because of a failure in
Clock Selection Library initialization: ([chars]/[chars]).
Explanation The initilaization of the Clock Selection Library failed. The Clock Selection Library is
used by the physical layer interface module (PLIM) driver on the linecard. The PLIM driver creates
the SONET controller and POS interface, handling the all the SONET event, applying SONET/POS
configuration to the layer-1 device hardware. If the PLIM driver fails to initialize, no traffic will
pass, therefore no higher level protocol will work. %s - indicates the reason for the failure %s - is
the decoded error reason
Recommended Action The System Manager process (sysmgr) will automatically respawn the PLIM
process, up to a fixed number of times when this error is encountered, to recover. Execute 'show
process process name location 0/x/cpu0' to verify that the process is up and running, where process
name equals 'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48 linecard;
If it is still non-operational, try to do a manually process restart with CLI: 'process restart location
0/x/cpu0'. If the message recurs, copy the error message exactly as it appears on the console or in
the system log, call your Cisco technical support representative and provide the representative with
the gathered information.
Error Message
%L1-PLIM_CLKSEL-4-ERR_DEBUG
Debug initialization failed with [chars].
Explanation Debug message initialzation failed.
Recommended Action This error has no effect on any feature except that debug information cannot be
turned on by CLI 'debug plim-clksel location 0/x/CPU0'. Restarting the process with the CLI below,
process restart will not affect traffic. 'process restart process name location 0/x/CPU0' may resolve
the problem.
PLIM_LIB Messages
Error Message
%L1-PLIM_LIB-2-ERR_FM_REPLY
Physical layer interface module library failed to
reply to the Fault Manager for error recovery: [chars]
Explanation The PLIM driver soft error recovery failed because the PLIM library function failed
with replying to the Fault Manager request. If the PLIM soft error recovery failed, the PLIM
hardware state may not be in the correct state, and the traffic may be affected. %s - is the decoded
error reason
Recommended Action The Fault Manager will reset the linecard if the error recovery failed, search
through the event logs, if there is no any message indicating that the Fault Manager has reset the
linecard, try to do a manually reset with CLI: 'hw-module location 0/x/cpu0 reload' If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%L1-PLIM_LIB-2-ERR_FM_REQUEST
The Fault Manager cannot send message to physical
layer interface module driver to start soft error recovery: [chars]/[chars]
Explanation When a soft error is detected with any ASIC on the datapath, the Fault Manager will
start the soft error recovery on the datapath. If the Fault Manager cannot send request to the PLIM
driver, the soft error recovery will not be completed, therefore the traffic will not go through the
datapath. %s - indicates the reason for the failure %s - is the decoded error reason
Recommended Action The Fault Manager will reset the linecard if sending message failed, search
through the event logs, if there is no any message indicating that the Fault Manager has reset the
linecard, try to do a manually reset with CLI: 'hw-module location 0/x/cpu0 reload' If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%L1-PLIM_LIB-3-ERR_INIT
Physical layer interface module library initialization
failed: ([chars]/[chars]).
Explanation The physical layer interface module (PLIM) library on the linecard failed to initialize.
The PLIM library is used by PLIM driver which creates the SONET controller, POS interface,
handling the all the SONET event and applying SONET/POS configuration to the layer1 devices. If
the PLIM driver failed to initialize, no traffic will pass, therefore no higher level protocol will work.
%s - indicates the reason for the failure %s - is the decoded error reason
Recommended Action The System Manager process (sysmgr) will automatically respawn the PLIM
process, up to a fixed number of times when this error is encountered, to recover. Execute the
following command to verify that the process is up and running. 'show process process name
location 0/x/cpu0' where process name equals 'e48_plim_oc3' for OC3 linecard;
'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48 linecard; If it is still
non-operational, try to do a manually process restart with CLI: 'process restart location 0/x/cpu0'.
If the message recurs, copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the
gathered information.
Error Message
%L1-PLIM_LIB-4-ERR_MSG_RCV
Physical layer interface module library failed in
receiving the message: [chars]
Explanation The PLIM library detects a failure condition when receiving the message. The message
is used only for error recovery, the process should not receive the message in normal case. This error
means a error condition is detected while the process is waiting for a message, it can be ignored if
the error does not persist. Otherwise, if the error persists, it is recommended to restart the process,
restarting process will not affect the traffic.
Recommended Action If the error persists, execute the following command to restart the process.
'process restart process name location 0/x/cpu0' where process name equals 'e48_plim_oc3' for
OC3 linecard; 'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48
linecard; If the message recurs, copy the error message exactly as it appears on the console or in the
system log, call your Cisco technical support representative and provide the representative with the
gathered information.
PLIM_OC3 Messages
Error Message
%L1-PLIM_OC3-2-ERR_HW_RESTART
Physical layer interface module hardware restart
for error recovery failed: [chars]: [chars]
Explanation The PLIM driver failed in soft error recovery. When a soft error is detected with any
ASIC on the datapath, the Fault Manager will start the soft error recovery on the whole datapath. If
the PLIM soft error recovery failed, the PLIM hardware state may not be in the correct state, and
the traffic may be affected. %s - indicates the reason for the failure %s - is the decoded error reason
Recommended Action The Fault Manager will reset the linecard if the error recovery failed, search
through the event logs, if there is no any message indicating that the Fault Manager resets the
linecard, try to do a manually reset with CLI: 'hw-module location 0/x/cpu0 reload' If the message
recurs, copy the error message exactly as it appears on the console or in the system log, call your
Cisco technical support representative and provide the representative with the gathered information.
Error Message
%L1-PLIM_OC3-3-ERR_INIT
Physical layer interface module driver initialization
failed: ([chars]/[chars]).
Explanation The physical layer interface module (PLIM) driver on the linecard failed to initialize.
The PLIM driver creates the SONET controller and POS interface, handling the all the SONET
event, applying SONET/POS configuration to the layer-1 device hardware. If the PLIM driver fails
to initialize, no traffic will pass, therefore no higher level protocol will work. %s - indicates the
reason for the failure %s - is the decoded error reason
Recommended Action The System Manager process (sysmgr) will automatically respawn this
process, up to a fixed number of times when this error is encountered, to recover. Execute 'show
process e48_plim_oc3 location 0/x/cpu0' to verify that the process is up and running. If it is still
non-operational, try doing 'process restart e48_plim_oc3 location 0/x/cpu0'. If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
Error Message
%L1-PLIM_OC3-3-ERR_TIMER
Unknown timer type detected, the timer is stopped.
Explanation The wrong timer type is detected while handling the timer event, the timer will be
stopped. The POS interface counter will not work if the timer is stopped, but the traffic will not be
affected.
Recommended Action Execute 'show int pos 0/x/0/x' while the traffic is running on the interface to
confirm if the counter is still working, if not, restart PLIM driver with CLI: 'process restart
e48_plim_oc3 location 0/x/cpu0' If the message recurs, copy the error message exactly as it appears
on the console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%L1-PLIM_OC3-4-ERR_DEBUG
Debug initialization failed with [chars].
Explanation Debug message initialzation failed.
Recommended Action This error has no effect on any feature except that debug information cannot be
turned on by CLI 'debug plim location 0/x/CPU0'. Restarting the process with CLI: 'process restart
e48_plim_oc3 location 0/x/CPU0' may resolve the problem.
PMENGINE Messages
Error Message
%L1-PMENGINE-4-TCA
Port [chars] reports [chars] [chars]([chars]) PM TCA with
current value [unsigned long long int], threshold [unsigned long long int] in
current [chars] interval window
Explanation The specified PM TCA has been declared.
Recommended Action Recommended action is to repair the source of the alarm.
SPA_OC3_OC12 Messages
Error Message
%L1-SPA_OC3_OC12-3-ERR_IF
[chars]
Explanation The SPA driver on the linecard failed to call SONET controll or POS interface related
system function. The issue may affect the creation of SONET controller or POS interface while the
SPA is booting, reloading or SFP OIR with different optics rate. %s - error message indicating
location and the reason of the error
Recommended Action - Try to do the SFP OIR for a few more times; - If the issue persists, reload the
SPA with the command: hw-module subslot 0/x/x reload then check if all the POS interface are
created, if not, reload LC. If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
Error Message
%L1-SPA_OC3_OC12-3-ERR_PLUGIN
[chars]
Explanation The operation on SPA object failed. The SPA driver controls all the hardware on the
SPA. If the operation on SPA fails, the SPA may not be able to boot or work properly, and the traffic
may be affected. %s - error message indicating location and the reason of the error
Recommended Action The SPA infra will automatically restart the SPA driver up to a fixed number
of times if the failure happens during SPA is booting. If the failure doesn't happen with SPA
booting, manually SPA reload may be needed. Execute 'show platform' to verify the SPA is in
READY state, if not, try to reload the SPA with command: hw-module subslot 0/x/x reload or if the
system has no response to the command above, force to reload the SPA with follwoing sequence
under config mode: hw-module subslot 0/x/x shutdown commit no hw-module subslot 0/x/x
shutdown commit If the message recurs, copy the error message exactly as it appears on the console
or in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%L1-SPA_OC3_OC12-3-ERR_RESTART
[chars]
Explanation There is an error detected during SPA process restart. During the process restart, the
software will do: checking the hardware config compatibility; re-creating SONET controller and
POS interface; restoring configurations. Any failure in above will cause restart failed. The traffic
may or may not be affected after restart failed, but the further operation on SPA, e.g. changing
configuration, may not be carried out properly. %s - error message indicating location and the reason
of the error
Recommended Action The system will try to restart the process again for a few times, If the issue
persists, reload the SPA with the command: hw-module subslot 0/x/x reload If the message recurs,
copy the error message exactly as it appears on the console or in the system log, call your Cisco
technical support representative and provide the representative with the gathered information.
Error Message
%L1-SPA_OC3_OC12-3-ERR_SFP
[chars]
Explanation There is an error detected during SFP initialization. SFP is the pluggable optics on the
SPA, SFP initialization may happen when linecard boots up, SFP OIR and SPA process restart. SFP
error is for any possible error during the initialization. The optics will not work if SFP OIR operation
failed, therefore no traffic will be affected. %s - error message indicating location and the reason of
the error
Recommended Action - Check the SFP, make sure it is CISCO certified; - Try to do the SFP OIR for
a few more times; - If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x
reload then test SFP OIR after SPA comes up. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information.
Error Message
%L1-SPA_OC3_OC12-6-INFO
[chars]
Explanation information message %s - message
Recommended Action none
Error Message
%L1-SPA_OC3_OC12-6-OPTICS_OIR
[chars]
Explanation Optics module has inserted %s - message related to the SFP insertion event
Recommended Action none
SPA_OC48 Messages
Error Message
%L1-SPA_OC48-3-ERR_INIT
SPA driver initialization failed in bay [dec]:
([chars]/[chars]).
Explanation The SPA driver on the linecard failed to initialize. The SPA driver controls all the
hardware on the SPA. If the SPA driver fails to initialize, no traffic will pass, no SPA related
infrastructure will work. %d - SPA bay number %s - indicates the reason for the failure %s - is the
decoded error reason
Recommended Action The SPA infra will automatically restart the SPA driver, up to a fixed number
of times when this error is encountered, to recover. Execute 'show platform' to verify the SPA is in
READY state, if not, try to reload the SPA with command: hw-module subslot 0/x/x reload or if the
system has no response to the command above, force to reload the SPA with follwoing sequence
under config mode: hw-module subslot 0/x/x shutdown commit no hw-module subslot 0/x/x
shutdown commit If the message recurs, copy the error message exactly as it appears on the console
or in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%L1-SPA_OC48-3-ERR_SFP_OIR
SFP OIR error in bay [dec]: ([chars]/[chars]).
Explanation There is an error detected during SFP OIR. SFP is the pluggable optics on the SPA, SFP
OIR can cause some operation in sw, e.g. create/delete optics object, SFP authentication. 'SFP OIR
error' is for any possible error during the operation. The optics will not work if SFP OIR operation
failed, therefore no traffic can pass. %d - SPA bay number %s - indicates the reason for the failure
%s - is the decoded error reason
Recommended Action - Check the SFP, make sure it is CISCO certified; - Try to do the SFP OIR for
a few more times; - If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x
reload then test SFP OIR after SPA comes up. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information.
Error Message
%L1-SPA_OC48-6-OPTICS_INSERTION
Optics module inserted into SPA in bay [dec],
port [dec]
Explanation Optics module has inserted %d - bay number %d - port number
Recommended Action none
Error Message
%L1-SPA_OC48-6-OPTICS_REMOVAL
Optics module removed from SPA in bay [dec], port
[dec]
Explanation Optics module has removed %d - bay number %d - port number
Recommended Action none
TREX_LIB Messages
Error Message
%L1-TREX_LIB-3-MSG_SEND_FAILED
msg: [dec], retried: [dec] time(s), failed to
send, errno: [chars]
Explanation This error message indicates a s/w problem. The details of the problem and traceback
are appended to the error msg. Contact support with this information.
Recommended Action *SUPPORT*
Error Message
%L1-TREX_LIB-7-DEBUG
[chars]
Explanation A harmless s/w problem occurred. The details of the problem and traceback are
appended to the error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log, call your Cisco technical support representative and provide the representative with the
gathered information.
TREX Messages
Error Message
%L1-TREX-2-HW_FATAL_ERROR
fatal error encountered by h/w - [chars], [chars]
Explanation An unrecoverable fatal error was detected by the service linecard h/w, which resulted
in linecard reload. The exact cause is appended to the error message. Contact support with this
information.
Recommended Action *SUPPORT*
Error Message
%L1-TREX-2-SW_FATAL_ERROR
fatal s/w error encountered - [chars], [chars]
Explanation An unrecoverable fatal s/w error was encountered, which resulted in process restart. The
exact cause is appended to the error msg. Contact support with this information.
Recommended Action *SUPPORT*
Error Message
%L1-TREX-3-BOARD_PLL_ERROR
board PLL error : IOFPGA register PLL_STATUS -
[hex][[hex]]
Explanation There is unexpected h/w state
Recommended Action If the problem persists reload the linecard. If that doesn't help, Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%L1-TREX-3-HW_NONFATAL_ERROR
nonfatal error encountered by h/w - [chars], [chars]
Explanation A nonfatal error was detected by the service linecard h/w. The exact cause is appended
to the error message. Contact support with this text.
Recommended Action If the error message appears rapidly, or if it persists, reload linecard. If that
doesn't help, Copy the error message exactly as it appears on the console or in the system log, call
your Cisco technical support representative and provide the representative with the gathered
information.
Error Message
%L1-TREX-3-PLL_ERROR
[chars] i/f PLL is unlock : register PLS - [hex]
Explanation There is unexpected h/w state
Recommended Action If the problem persists reload the linecard. If that doesn't help, Copy the error
message exactly as it appears on the console or in the system log, call your Cisco technical support
representative and provide the representative with the gathered information.
Error Message
%L1-TREX-5-NOTICE
[chars]
Explanation Unexpected event occurred in the service linecard with no effect on functionality
Recommended Action *NONE*
Error Message
%L1-TREX-6-INFO
[chars]
Explanation Service linecard's driver informational message
Explanation *NONE*
UT2 Messages
Error Message
%L1-UT2-7-ERR_MSG
ERR: [chars]: cerrno [dec]
Explanation ut2 driver might run into an error that is not a FATAL.
Recommended Action If the message recurs, copy the error message exactly as it appears on the
console or in the system log, call your Cisco technical support representative and provide the
representative with the gathered information.
XENA Messages
Error Message
%L1-XENA-2-HW_FATAL_ERROR
fatal error encountered by h/w - [chars]
Explanation An unrecoverable fatal error was detected by service card h/w, which resulted in
linecard reload. The exact cause is appended to the error msg. Contact support with this information.
Recommended Action *SUPPORT*
Error Message
%L1-XENA-2-SW_FATAL_ERROR
fatal s/w error encountered - [chars], [chars]
Explanation An unrecoverable fatal s/w error was encountered, which resulted in process restart. The
exact cause is appended to the error msg. Contact support with this information.
Recommended Action *SUPPORT*
Error Message
%L1-XENA-5-NOTICE
[chars]
Explanation Unexpected event occurred in service linecard with no effect on functionality
Recommended Action *NONE*