Table Of Contents
Layer 1 Messages
SPA_OC48 Messages
Layer 1 Messages
This section contains all Layer 1 related System Error Messages. The following facility codes are represented in this module:
•
SPA_OC48 Messages
SPA_OC48 Messages
Error Message
%L1-SPA_OC48-3-ERR_INIT
SPA driver initialization failed in bay [dec]:
([chars]/[chars]).
Explanation The SPA driver on the linecard failed to initialize. The SPA driver controls all the
hardware on the SPA. If the SPA driver fails to initialize, no traffic will pass, no SPA related
infrastructure will work. %d - SPA bay number %s - indicates the reason for the failure %s - is the
decoded error reason
Recommended Action The SPA infra will automatically restart the SPA driver, up to a fixed number
of times when this error is encountered, to recover. Execute 'show platform' to verify the SPA is in
READY state, if not, try to reload the SPA with command: hw-module subslot 0/x/x reload or if the
system has no response to the command above, force to reload the SPA with follwoing sequence
under config mode: hw-module subslot 0/x/x shutdown commit no hw-module subslot 0/x/x
shutdown commit If the message recurs, copy the error message exactly as it appears on the console
or in the system log, call your Cisco technical support representative and provide the representative
with the gathered information.
Error Message
%L1-SPA_OC48-3-ERR_SFP_OIR
SFP OIR error in bay [dec]: ([chars]/[chars]).
Explanation There is an error detected during SFP OIR. SFP is the pluggable optics on the SPA, SFP
OIR can cause some operation in sw, e.g. create/delete optics object, SFP authentication. 'SFP OIR
error' is for any possible error during the operation. The optics will not work if SFP OIR operation
failed, therefore no traffic can pass. %d - SPA bay number %s - indicates the reason for the failure
%s - is the decoded error reason
Recommended Action - Check the SFP, make sure it is CISCO certified; - Try to do the SFP OIR for
a few more times; - If the issue persists, reload the SPA with the command: hw-module subslot 0/x/x
reload then test SFP OIR after SPA comes up. If the message recurs, copy the error message exactly
as it appears on the console or in the system log, call your Cisco technical support representative
and provide the representative with the gathered information.
Error Message
%L1-SPA_OC48-6-OPTICS_INSERTION
Optics module inserted into SPA in bay [dec],
port [dec]
Explanation Optics module has inserted %d - bay number %d - port number
Recommended Action none
Error Message
%L1-SPA_OC48-6-OPTICS_REMOVAL
Optics module removed from SPA in bay [dec], port
[dec]
Explanation Optics module has removed %d - bay number %d - port number none