CMCC ADAPTER Messages
CMCC ADAPTER Messages
The following are Channel Interface Processor (CIP) error messages for the adapter task.
Error Message
%ADAPTER-6-BADREQUEST
: Bad request code [dec] generated on port [dec]
Explanation A request was sent to the function that handles general requests for the specified port.
The request code was not in a range recognized by that function.
Recommended Action The CIP has recovered by ignoring the request. Copy the error message exactly as
it appears on the console or in the system log, contact your Cisco technical support representative, and
provide the representative with the gathered information.
Error Message
%ADAPTER-6-BADSTATE
: Bad state: port [dec], request code [dec], state [dec], flags
[hex]
Explanation The specified port was in an invalid state while it was attempting to process the specified
general request.
Recommended Action The CIP recovered by forcing the port into a valid state. Copy the error message
exactly as it appears on the console or in the system log, contact your Cisco technical support
representative, and provide the representative with the gathered information.
Error Message
%ADAPTER-6-DIAGBEGIN
: [chars] diagnostic starting
Explanation The user has used the test cbus command to request a particular adapter diagnostic to be
run. This message informs the user that the diagnostic routine has started.
Recommended Action Wait for the next message.
Error Message
%ADAPTER-0-DIAGDATA
: Module Call: [hex][hex] Error ID: [hex][hex]
Explanation A diagnostic routine has detected a failure in the ECA hardware. The indicated codes are used
to locate the specific component that failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-DIAGDATA2
: Module Call: [hex][hex] Error ID: [hex][hex]
Explanation A diagnostic routine has detected a failure in the ECA hardware. The indicated codes are used
to locate the specific component that failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-0-DIAGFAIL
: Port [dec] failed the [chars] diagnostic
Explanation A diagnostic routine has failed. The specified port will not be used.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-DIAGFAIL2
: [chars] diagnostic failed
Explanation A diagnostic requested by the test cbus command has failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-DIAGGOOD2
: [chars] diagnostic ran successfully
Explanation A diagnostic requested by the test cbus command has completed successfully.
Recommended Action No action is required.
Error Message
%ADAPTER-6-DIAGRANGE
: Diagnostic number ([dec]) out of range 0-[dec]
Explanation The diagnostic number requested by the test cbus command is invalid.
Recommended Action Reenter the command with a valid diagnostic number.
Error Message
%ADAPTER-6-DIAGSTOP
: Interface must be shutdown to run diagnostic
Explanation The test cbus command was used to run a diagnostic on an active interface. The interface
must be shut down before the diagnostic is run.
Recommended Action Use the shutdown command to stop the interface and then reissue the diagnostic
request.
Error Message
%ADAPTER-0-DIAGTERM
: Port [dec]: The [chars] diagnostic failed to terminate
Explanation A diagnostic routine did not end when expected. The specified port will not be used.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-DIAGTERM2
: [chars] diagnostic failed to terminate
Explanation A diagnostic requested by the test cbus command did not end when expected.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-0-LOADFAIL
: Port [dec] microcode load failed.
Explanation Each adapter has an onboard microprocessor. This message indicates that the operation to
load the code for that microprocessor has failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-LOGDATA
: [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex]
Explanation An error has occurred in the adapter. The information displayed will help software developers
determine the nature of the error.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-LOGOUT
: Port [dec] logout data. Adapter microcode [hex]
Explanation This message indicates the start of the logout data. Logout data occurs whenever a problem
is detected on the port adapter or, with an ECA, on the fiber.
Recommended Action If this message is being continually generated on a new installation, it may indicate
that the fiber is not connected properly. Verify that the connector is firmly seated. If a loose fiber was not
the cause of these messages, report this message to your Cisco technical support representative.
Error Message
%ADAPTER-6-LOGSAME
: [hex] to [hex] same as above
Explanation This message is used when logout information is displayed to avoid printing duplicate data.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-NO_CHAN_EV_BUF
: No channel event buffer: Daughter board [dec]
Explanation Channel link incident events are being dropped by the channel adapter because of an
overflow of incidents.
Recommended Action Use SNMP to poll the CIP for the current LIR counts.
Error Message
%ADAPTER-6-NO_CHAN_EV_POOL
: Could not allocate channel event pool
Explanation There is insufficient memory on the channel adapter to allocate buffers used for generating
channel adapter events. Unless the memory is increased, no channel link incident events (SNMP traps)
will be generated.
Recommended Action Add more memory to the channel adapter.
Error Message
%ADAPTER-6-SCAN
: Port [dec] scan data. Adapter microcode [hex]
Explanation This message precedes the "SCANDATA" error message for the adapter in the specified
port. This scan is usually produced as a result of a hardware error.
Recommended Action Report the entire error message, including the "SCANDATA" error message that
follows it, to your Cisco technical support representative.
Error Message
%ADAPTER-6-SCANDATA
: [hex] [hex] [hex] [hex] [hex]
Explanation The data in this message is related to the hardware failure of an adapter.
Recommended Action Report the entire error message, including the preceding "SCAN" error message, to
your Cisco technical support representative.
Error Message
%ADAPTER-0-START_FAIL
: Diagnostics failed for port [dec], start request ignored.
Explanation Prior to receipt by the adapter of a start command from the Route Processor, a set of
diagnostics is run. If one of them fails, then the adapter will not be started when the start command
is issued.
Recommended Action Copy the error message exactly as it appears on the console or in the system log,
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Error Message
%ADAPTER-6-WRAP
: Wrap plug detected in port [dec]. Wrap loop started.
Explanation A wrap plug is installed in the specified port. Wrap diagnostics will run until the wrap plug
is removed, if this is the only adapter, or until both adapters have wrap plugs installed.
Recommended Action Remove the wrap plug and connect the interface to a channel.
Error Message
%ADAPTER-6-WRAPSTOP1
: Wrap plug removed from port [dec]. Wrap loop ended.
Explanation The wrap plug has been removed, causing the wrap diagnostics to end.
Recommended Action No action is required.
Error Message
%ADAPTER-6-WRAPSTOP2
: Port [dec] active. Port [dec] wrap loop ended.
Explanation The wrap diagnostics have ended because the other adapter is active.
Recommended Action Remove the wrap plug and connect the interface to a channel if you wish to use this
adapter. Otherwise, no action is required.