Cisco IOS System Error Messages, Volume 1 of 2
C6MSFC through CHOPIN_MAINBOARD_ASYNC_PQII

Table Of Contents

C6MSFC Messages

C6SUP Messages

C7200 Messages

C7200_TDM Messages

CAIM Messages

CALL_CONTROL Messages

CALL_MGMT Messages

CALLPROG Messages

CALLRECORD Messages

CALLTRKR Messages

CARRIER Messages

CASA Messages

CBUS Messages

CCH323 Messages

CCPROXY Messages

CDM Messages

CDP Messages

CE3 Messages

CES Messages

CHOPIN Messages

CHOPIN_MAINBOARD_ASYNC_PQII Messages


C6MSFC Messages

The following are C6MSFC (Draco) error messages.

Error Message 

%C6MSFC-4-BADFLASH : Unsupported flash type in the bootflash - [chars].

Explanation    The Flash chip in the Flash SIMM is not supported by the platform.

Recommended Action    Contact your Cisco technical support representative for assistance in updating your system.

Error Message  

%C6MSFC-3-CHASSIS : Unknown chassis model.

Explanation    The data stored in the CPU ID PROM is bad or incomplete.

Recommended Action    Contact your Cisco technical support representative for assistance in updating your system.

Error Message 

%C6MSFC-3-CONFIG : Recommended port adapter configuration exceeded

Explanation    The number of port adapters configured is greater than the number supported for this system.

Recommended Action    Verify that you are using the correct port adapters, check your system requirements, and correct the configuration.

Error Message  

%C6MSFC-4-COOKIE : Corrupt or missing MAC address cookie
using random base [enet]

Explanation    The MAC address could not be detected. It may have been corrupted or be missing.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%C6MSFC-3-IONOT0 : IO card discover in non-zero slot [dec]

Explanation    An I/O card has been detected in the nonzero slot indicated in the error message.

Recommended Action    Verify that the card is in the correct slot and that the configuration is correct. Try the operation again.

Error Message  

%C6MSFC-4-MACBLKSIZE : Unknown MAC address block size.

Explanation    The data stored in the CPU ID PROM is bad or incomplete.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%C6MSFC-3-NOCPUVER : Invalid CPU Revision [dec].

Explanation    The CPU version could not be verified.

Recommended Action    The system may need to be upgraded. Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%C6MSFC-3-NOMAC : Can't allocate MAC address for interface [int]/[int]

Explanation    The MAC address for the interface indicated in the message could not be allocated.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

C6SUP Messages

The following are C6SUP-specific error messages.

Error Message  

%C6SUP-3-NOVLANMAC : Can't allocate MAC address for VLAN interface [int]

Explanation    The allocation of the MAC address has failed because the VLAN number is outside the range supported by the chassis.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

C7200 Messages

The following are error messages for the Cisco 7200 platform.

Error Message    

%C7200-2-BADDAT : PA interface data incorrect, [hex]

Explanation    Incorrect port adapter (PA) interface data has been found.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADIDB : PA interface idb incorrect, [hex]

Explanation    The port adapter system control block (PASCB) data structure indicates a zero interface descriptor block (IDB).

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADINTERFACE : Out of range PCI Port Adaptor interface, [dec] on bay [dec]

Explanation    The software specified an out-of-range port adapter interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADPA : PA interface pa incorrect, [hex]

Explanation    An incorrect port adapter (PA) interface has been specified.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADPA2 : PA null adapter, [hex]

Explanation    A null port adapter (PA) interface has been specified.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADPABAY : Out of range PCI Port Adaptor bay [dec]

Explanation    The software specified an out-of-range port adapter bay.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADPASCB : PA interface pascb incorrect, [hex]

Explanation    The port adapter system control block (PASCB) data structure was incorrectly set in the command data structure.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADPINST : PA interface port_inst incorrect, [hex]

Explanation    An attempt to access port instance internal data has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-BADVCONT : PA interface vcont incorrect, [hex]

Explanation    An incorrect virtual circuit (VC) interface has been specified.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-3-BRINGUPFAIL : port adapter in bay [[dec]] failed to reset.

Explanation    An attempt to reset and initialize the port adapter has timed out.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-3-CONFIG : Recommended port adapter configuration exceeded

Explanation    The total bandwidth of fast and medium bandwidth port adapters has exceeded the rated capacity of this system.

Recommended Action    Refer to the configuration guidelines for the maximum allowed fast and medium bandwidth port adapters for the system.

Error Message    

%C7200-3-DEACTIVATED : port adapter in bay [[dec]] powered off

Explanation    The port adapter is being powered off.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-ILLEGALPA : Illegal Port Adaptor type [dec] in bay [dec] of [chars].

Explanation    The port adapter is not supported by the controller into which it is plugged.

Recommended Action    Remove the port adapter and return the controller to its original configuration.

Error Message     

%C7200-2-INCORRECTBRIDGEREG : Bad default register([hex]) setting([hex]) in PA bridge

Explanation    The software is unable to configure certain settings for the port adapter protocol control information (PCI) bridge in the specified bay.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-3-NOTSUPPORTED : PA in slot[dec] ([chars]) is not supported on this [chars]

Explanation    This port adapter is not supported on this chassis or CPU card.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-PABRIDGE : Failed to config bridge for PA [dec]

Explanation    The system side protocol control information (PCI) bridge for this port adapter (PA) has failed initialization. The PA therefore will not be operational.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-3-PACREATE : Unable to create driver for Port Adaptor type [dec] in bay [dec]

Explanation    This message indicates a possible memory shortage or port adapter hardware error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-PARECUR : Recursive loop while getting the daughtercard info for PA type [dec]

Explanation    While retrieving the daughter card information for the chassismib, the platform Simple Network Management Protocol (SNMP) code has gone into an infinite loop.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-4-PCIVALID : PCI activation failed, bay [dec], 0x[hex]

Explanation    The system has received an invalid protocol control information (PCI) signal from the specified port adapter. This error was probably caused by a hardware failure.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-QOVERFLOW : PA queue overflow, cmd [hex]

Explanation    The port adapter (PA) queue has overflowed and the programming has been lost.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-3-REVNOTSUPPORTED : PA in slot[dec] ([chars]) requires base h/w revision of ([dec].[dec]) for this [chars]

Explanation    A newer hardware revision of the port adapter is required for functional operation on this chassis.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    

%C7200-0-RUPTCONFLICT : Conflict detected when trying to install [chars] interrupt handler, bay [dec].

Explanation    An attempt was made to register an interrupt handler either for a nonexistent port adapter or for the wrong interrupt priority level.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-UNDEFPA : Undefined Port Adaptor type [dec] in bay [dec]

Explanation    The software does not have a driver for the specified port adapter type located in the specified bay.

Recommended Action    Ensure that the image you are running supports this card. Check that the card is properly seated. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

Error Message     

%C7200-2-UNDEFPABRIDGE : Unsupported Port Adaptor Bridge [hex] in bay [dec]

Explanation    The software does not have a driver for that port adapter protocol control information (PCI) bridge located in the specified bay.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative, and provide the representative with the gathered information.

C7200_TDM Messages

The following are Cisco 7200 midplane TDM bus error messages.

Error Message  

%C7200_TDM-3-TDM_CLOSE : MT90820 Midplane Close connection failed - STo[dec], CHo[dec]

Explanation    An attempt to disable the midplane TDM connection has failed.

Recommended Action    This message is informational. No action is required.

Error Message  

%C7200_TDM-3-TDM_INV_CONN_REQ : Upper Layer made invalid TDM request - STo[dec], CHo[dec]

Explanation    An invalid request to use the TDM midplane has been made.

Recommended Action    This message is informational. No action is required.

Error Message  

%C7200_TDM-3-TDM_INV_DISC_REQ : Upper Layer made invalid TDM request - STo[dec], CHo[dec]

Explanation    An invalid request to use the TDM midplane has been made.

Recommended Action    No action is required.

Error Message 

%C7200_TDM-3-TDM_OPEN : MT90820 Midplane Open connection failed - STi[dec], CHi[dec], STo[dec], CHo[dec]

Explanation    An attempt to open a midplane TDM connection has failed.

Recommended Action    This message is informational. No action is required.

CAIM Messages

The following are Compression Advanced Interface Module (CAIM) error messages.

Error Message  

%CAIM-1-ELMERREV : AIM in slot [int] not supported by this HW revision.

Explanation    The revision level of the C2600 Elmer PLD does not support Compression AIM.

Recommended Action    The C2600 Elmer PLD needs to be reprogrammed to a later revision. Refer to Cisco.com release notes for the Cisco C2600 and Compression AIM for an explanation of how to reprogram the PLD.

Error Message  

%CAIM-1-HIFNERR : Caim [int]: Hifn 9711 Errors reported: 9711 Status [hex] DMA status [hex]

Explanation    The specified Compression AIM reported a Hifn9711 error.

Recommended Action    This is an indication of a serious malfunction of the Compression AIM or of the system bus. The Compression AIM should be replaced.

Error Message  

%CAIM-1-HIFNREV : Compression AIM type in slot [int] is not supported by this platform.

Explanation    The Compression AIM that is installed is not supported by this platform.

Recommended Action    Power off and replace the Compression AIM card.

Error Message  

%CAIM-1-INITFAIL : CAIM [dec]: Initialization failed at [chars]

Explanation    The Compression AIM device would not reset properly. This behavior indicates a Compression AIM hardware failure.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CAIM-1-INVELMT : Invalid CAIM element: [dec]

Explanation    The Compression AIM element number specified in the command is not valid.

Recommended Action    Compression AIM element numbers range from 0 to one less than the number of Compression AIMs possible in your system. Verify the number of Compression AIMs present in your system.

Error Message  

%CAIM-1-NODEV : AIM slot [dec]: Could not locate Compression AIM; found PCI vendor id [hex] instead

Explanation    The AIM ID PROM indicates that a Compression AIM is present but the PCI vendor or device ID was not the one that was expected for a Compression AIM.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CAIM-1-NOMEMORY : CAIM [dec]: Memory allocation failure; could not allocate [chars]

Explanation    An attempt to allocate memory for the specified Compression AIM has failed. More RAM may be required to execute this image.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message 

%CAIM-1-NOSUCH : No such CAIM element: [dec]

Explanation    The Compression AIM element number specified is not present in the system.

Recommended Action    Compression AIM element numbers range from 0 to one less than the number of Compression AIMs present in your system. Verify the number and presence of Compression AIMs in your system.

Error Message  

%CAIM-1-PCIABT : Caim [int]: PCI Abort reported: status [hex]

Explanation    The specified Compression AIM has reported a bus error (PCI Abort).

Recommended Action    This is an indication of a serious malfunction of the Compression AIM or of the system bus. The Compression AIM should be replaced. A second possible explanation is that there is a mismatch in the configured compression algorithm on either side of a serial link. Such a mismatch can also give rise to PCI Abort problems. The recommended action in such cases is to configure matching compression algorithms on either side of the link and then to reboot the router which experienced the PCI Abort.

Error Message  

%CAIM-6-SHUTDOWN : [chars] shutting down

Explanation    The specified Compression AIM is shutting down. It may have been physically removed. This message also occurs when the clear aim command is used.

Recommended Action    This is an informational message only and occurs in normal operation. No action is required.

Error Message  

%CAIM-6-STARTUP : [chars] starting up

Explanation    The specified Compression AIM has initialized successfully.

Recommended Action    This is an informational message only and occurs in normal operation. No action is required.

Error Message  

%CAIM-1-UNEXPINT : Unexpected AIM Interrupt

Explanation    The system has received an AIM interrupt from an unknown AIM device. There is no recognizable AIM installed in the system, yet the AIM interrupt was received.

Recommended Action    If there is a Compression AIM unit installed in the Cisco C2600, then it is defective and must be replaced. If there is some other AIM installed in the Cisco C2600, it must be removed. If there is no AIM installed, then the Cisco C2600 unit is defective and must be replaced.

CALL_CONTROL Messages

The following are network call control error messages.

Error Message  

%CALL_CONTROL-6-APP_NOT_EXIST : The requested application does not exist any more. The event for the callid [dec] is being discarded.\n

Explanation    The event points to a session application that does not exist any more. The event is being discarded.

Recommended Action    No action is required.

Error Message  

%CALL_CONTROL-6-APP_NOT_FOUND : Application [chars] in dial-peer [dec] not found.
Handing callid [dec] to default app.\n

Explanation    The inbound dial peer points to a session application that is not registered. The call is being handed to the default application.

Recommended Action    Reconfigure the dial peer and assign it a valid application name.

Error Message  

%CALL_CONTROL-6-CALL_LOOP : The incoming call has a global identfier already present in the list of currently handled calls. It is being refused.\n

Explanation    The incoming call has a global identifier that is already present in the list of currently handled calls. A global identifier can be used by only one call at a time.

Recommended Action    Check your configuration. The call may be misdirected.

Error Message  

%CALL_CONTROL-6-MAX_CONNECTIONS : Maximum number of connections reached for dial-peer [dec]\n

Explanation    The dial peer in question has reached its maximum number of configured connections. No more calls will be taken on this dial peer.

Recommended Action    No action is required; however, to increase the number of connections allowed to this dial peer, you can adjust the maximum connections configuration setting while in dial-peer configuration mode.

Error Message  

%CALL_CONTROL-3-NORAWMSG : no free raw msg structure available from [chars] for signaling message

Explanation    There were no raw message structures remaining in the system pools to alert the router of a voice or signaling event.

Recommended Action    Verify that the voice port for which the event was reported is still operational. If the port is not operational, clear the voice port.

Error Message  

%CALL_CONTROL-6-NUMBERING_TYPE_NO_MATCH : The called number numbering type did not matchThe event for the callid [dec] is being discarded.\n

Explanation    The event points to a session application that no longer exists. The event is being discarded.

Recommended Action    This message is informational. No action is required.

CALL_MGMT Messages

The following are call management subsystem error messages.

Error Message  

%CALL_MGMT-4-CALL_DISC : [chars]

Explanation    The specific message text is supplied by the call management software. This indicates that a call record is missing from the active call list.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CALL_MGMT-1-CALL_LIST : [chars]

Explanation    The specific message text is supplied by the call management software. This indicates that internal data was corrupted as a result of a software error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CALL_MGMT-1-CPM_Q_POOL : [chars]

Explanation    The specific message text is supplied by the call management software; it indicates a condition of memory exhaustion.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message  

%CALL_MGMT-1-INITSYS : [chars]

Explanation    The specific message text is supplied by the call management software. This indicates an initialization failure. When this occurs, the call management subsystem is not operational.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CALLPROG Messages

The following are error messages for the call progress notification subsystem.

Error Message  

%CALLPROG-3-API_INIT : api front init failed for [chars]

Explanation    An attempt to initialize call progress notification support structures for APIs has failed.

Recommended Action    The system is running low on available memory. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message 

%CALLPROG-3-API_USE : no free front-end q elt's; dropping api call info (func=[dec])

Explanation    The system was unable to get a free element from the front end queue.

Recommended Action    The platform requires additional free elements in order to function properly. Stop using call progress notification applications. Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CALLRECORD Messages

The following are Modem Call Record error messages.

Error Message 

%CALLRECORD-3-MCOM_TERSE_CALL_FAILED_REC : [chars]

Explanation    An attempt to write a terse Mcom call record has failed.

Recommended Action    No action is required.

Error Message  

%CALLRECORD-3-MCOM_TERSE_CALL_REC : [chars]

Explanation    A terse Mcom call record was written successfully.

Recommended Action    No action is required.

Error Message  

%CALLRECORD-6-MICA_TERSE_CALL_FAILED_REC : [chars]

Explanation    An attempt to write a terse MICA call record has failed.

Recommended Action    No action is required.

Error Message  

%CALLRECORD-6-MICA_TERSE_CALL_REC : [chars]

Explanation    A terse MICA call record was written.

Recommended Action    No action is required.

Error Message  

%CALLRECORD-3-MODEM_CALL_REC_ERROR : [chars]

Explanation    The generated record has exceeded the SYSLOG capacity.

Recommended Action    No action is required.

CALLTRKR Messages

The following are Call Tracker subsystem error messages.

Error Message  

%CALLTRKR-3-CALL_REC_ERROR : [chars]

Explanation    The generated record has exceeded the SYSLOG capacity.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-6-CALL_RECORD : [chars]

Explanation    A terse Call Tracker call record was written.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-6-MODEM_CALL_REC : [chars]

Explanation    A modem verbose Call Tracker call record has occurred.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-6-MODEM_INFO_CALL_REC : [chars]

Explanation    A modem information verbose Call Tracker call record has occurred.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-6-MODEM_LINE_CALL_REC : [chars]

Explanation    A modem line verbose Call Tracker call record has occurred.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-6-MODEM_NEG_CALL_REC : [chars]

Explanation    A modem negotiation verbose Call Tracker call record has occurred.

Recommended Action    No action is required.

Error Message  

%CALLTRKR-3-NO_MEM : Memory allocation failed for CT [chars] ([dec] bytes)

Explanation    Call Tracker could not allocate a new record because no free memory was available.

Recommended Action    Disable Call Tracker using the no calltracker enable command. Run the show memory command to find out where memory has been allocated. Adjust system activity and resources as necessary.

Error Message  

%CALLTRKR-3-PRINT_BUFFER : calltrkr cli print buffer [chars]

Explanation    The Call Tracker command-line interface internal print buffer has reached overflow capacity.

Recommended Action    Stop using Call Tracker show commands. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CALLTRKR-3-PROC : can't spawn [chars]

Explanation    The Call Tracker process could not be started.

Recommended Action    Disable Call Tracker using the no calltracker enable command. Enable it and try the process again.

Error Message  

%CALLTRKR-3-TBL_INIT : Init of CT's [chars] table failed; CT unusable

Explanation    The Call Tracker record table could not be initialized.

Recommended Action    Disable Call Tracker using the no calltracker enable command. Enable it and try the operation again.

CARRIER Messages

The following are DFC carrier error messages.

Error Message  

%CARRIER-2-CT3_8PRI_MIX : Cannot mix 8PRI and CT3 DFC in chassis, do not power up invalid card in slot [dec]\n

Explanation    The user has put 8PRI and CT3 DFCs in the same chassis.

Recommended Action    These card types cannot be mixed. Remove the extra 8PRI or CT3 DFC.

Error Message  

%CARRIER-3-DFC_INIT_ALREADY : DFC is already initialized - DFC [dec]

Explanation    The DFC is already initialized; there is no need to initialize it again.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-DFC_INIT_FAIL : DFC initialization is failed - DFC [dec]

Explanation    DFC initialization has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-DFC_POWER_INT : DFC Power Changed - DFC [dec]

Explanation    Power is fluctuating on the DFC.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-INVALID_DFC : Invalid DFC - DFC [dec] type [dec]

Explanation    The DFC has an invalid board ID or board type.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-NO_DFC : DFC is not present - DFC [dec]

Explanation    The DFC is not present in the carrier card.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-PLATFORM_DFC : DFC Carrier Platform Init Failed - Slot [dec]

Explanation    Initialization of the DFC carrier platform has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-POWER_DFC : DFC Power-On Failed - DFC [dec]

Explanation    An attempt to power on the DFC has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-3-RESET_DFC : DFC Reset Failed - DFC [dec]

Explanation    The DFC reset failed during the online removal process.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-2-T1_E1_MIX : Cannot mix T1 and E1 8PRI DFC cards in chassis, do not power up invalid card in slot [dec]\n

Explanation    T1 and E1 8PRI DFCs are present in the same chassis.

Recommended Action    These card types cannot be mixed in the same system. Remove the extra T1 or E1 8PRI DFC.

Error Message  

%CARRIER-2-THREE_NP108_NOT_PRESENT : 3 NP108s were not found on Tetryl card, [dec] detected.

Explanation    Tetryl requires 3 NP108 cards to be present.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CARRIER-2-TOOMANY_8PRI : Too many 8PRI DFC cards, do not power up invalid card in slot [dec]\n

Explanation    Too many 8PRI DFCs are installed in the chassis.

Recommended Action    Remove the extra 8PRI DFC.

Error Message  

%CARRIER-2-TOOMANY_CT3 : Too many CT3 DFC cards, do not power up invalid card in slot [dec]\n

Explanation    Too many CT3 DFCs are installed in the chassis.

Recommended Action    Remove the extra CT3 DFC or the 8PRI DFC that is causing the problem.

CASA Messages

The following are Cisco Appliance and Services Architecture (CASA) error messages.

Error Message  

%CASA-4-BADMSG : Message parsing error: [chars]

Explanation    An incoming packet could not be parsed.

Recommended Action    If this message is occurring repeatedly, enable debugging by entering the debug ip casa error command and record the output. Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CASA-3-BADVER : Incoming packet is CASA v[dec], this router is v[dec]

Explanation    A packet was received for the wrong version of CASA.

Recommended Action    Verify that all CASA devices are running the same version of the protocol.

Error Message  

%CASA-2-NOMEM : Out of memory: [chars]\n

Explanation    CASA has failed to allocate memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message  

%CASA-4-PORTCHANGE : Wildcard overlap: [chars]

Explanation    A CASA wildcard, received on one port, has been overwritten by a service manager sending to another port. This message may appear once if your service is migrating to a new forwarding-agent port; if it recurs, it could indicate a configuration problem.

Recommended Action    Verify the configurations. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CASA-4-SECURITY_FAIL : [chars] security information in CASA packet.

Explanation    A security check has failed.

Recommended Action    Verify that all CASA systems are configured with the same password.

Error Message  

%CASA-4-UNEXPECTED : Unexpected error: [chars]

Explanation    An unexpected error occurred during a CASA operation.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CASA-4-WARNING : Unexpected condition: [chars]

Explanation    An unexpected condition was detected during a CASA operation.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CBUS Messages

The following are ciscoBus controller error messages.

Error Message  

%CBUS-3-ADDRFILTR : Interface [chars], address filter [chars] command failed, code [hex]

Explanation    The specified address filter command, which was sent to the specified interface, has failed with the displayed error code.

Recommended Action    Copy the message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-AIPINVPLIM : Interface [chars], Invalid PLIM detected. Interface downed

Explanation    A software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-BADRXEOFVEC : [chars] ustatus: [chars] ([hex]), [hex] [hex] [hex] [hex]

Explanation    This message provides debugging information when an IP panic occurs.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-BADTXEOFVEC : [chars] ustatus: [chars] ([hex]), [hex] [hex] [hex] [hex]

Explanation    This message provides debugging information when an IP panic occurs.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-BADTXSTATE : [chars] ustatus: [chars] ([hex]), [hex] [hex] [hex] [hex]

Explanation    This message provides debugging information when an IP panic occurs.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-BADVC : [chars] [dec]/[dec] got bad VC packet
[hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex]

Explanation    An interface has received a packet with bad VC encapsulation. This indicates either a software or hardware problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-BUFFER : Controller [dec], Error ([hex]), Buffersize = [dec], Bufferpool = [dec], number [dec]

Explanation    An internal software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CATMCFG : Interface [chars], Cannot config interface, CBus ATM MEM [hex], status [dec]

Explanation    A software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-CATMREJCMD : [chars] [chars] command failed (error code [hex])

Explanation    The ciscoBus ATM microcode rejected a command sent by the route processor (RP). The error code is the status value returned by the command.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CATMRSET : Interface [chars], Error ([hex]) [chars] - aip_reset()

Explanation    A software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CATMRSETU : Unit [dec], Error ([hex]) [chars] - cbus_atm_reset()

Explanation    A software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-5-CBADVCSETUP : Interface [chars], setup vc failed with vci exceeding (vc-per-vp - 3) on the last vpi.

Explanation    The TI1570 chip reserves three Rx DMA channels for OAM cells. As a result, the last three VCIs of the last VPI block cannot be used for regular traffic.

Recommended Action    Avoid trying different VCI and VPI combinations.

Error Message  

%CBUS-3-CBUSBCE : Failed to select a BCE, response [hex] - cbus_bce_update_ifa()

Explanation    A hardware or software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CBUSBCEPERM : Failed to select a BCE, response [hex] - cbus_bce_permissions_update()

Explanation    A hardware or software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CCBCMDFAIL0 : Controller [dec], cmd ([dec]) failed ([hex])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating and sending an error code to the requester. No action is required.

Error Message  

%CBUS-3-CCBCMDFAIL1 : Controller [dec], cmd ([dec] [hex]) failed ([hex])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating and sending an error code to the requester. No action is required.

Error Message  

%CBUS-3-CE3DSX3ERR : ([chars])Illegal E3 value - unit is [dec]

Explanation    The internal data structure is corrupted. The corruption has caused the "love letter" (operating status or configuration message) to be dropped.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CFGCMDDROPPED : Config queue is full, command was dropped, slot [dec]

Explanation    The sending of a configuration command was retried. The receiving queues were still full after retries; therefore the command was dropped.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-CMDTIMEOUT : Cmd timed out, CCB 0x[hex], slot [dec], cmd code [dec]

Explanation    A software or hardware error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CBUS-3-CORRUPT : Controller [dec], wrote [hex], read [hex], loc [hex] - dci_memtest()

Explanation    A hardware component has failed an internal diagnostic test.

Recommended Action    Replace the malfunctioning device.

Error Message  

%CBUS-3-CT3STAT : Out of buffers--losing status information for CT3 on VIP card

Explanation    An internal software resource has been exhausted.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRACHECK : Interface [chars], Adapter Check Error ([hex] [hex] [hex] [hex])

Explanation    The Token Ring monitor firmware has detected a fatal error on the interface card.

Recommended Action    Issue a clear interface command. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRBADLOVE1 : Interface [chars], SRB_COMPLETE lovenote received with unknown command ([hex])

Explanation    The system has received a message from the token-ring interface but does not recognize the message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRBADLOVE1_DUMP : Dump of MEMB follows
-SRB_ADDR: [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex]

Explanation    The system is printing codes related to a previous "love letter" (operating status or configuration message) error message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-4-CTRBADLOVE2 : Interface [chars], Unexpected SRB_COMPLETE lovenote, command=[hex], result=[hex]

Explanation    The system has received an unsolicited message from the token-ring interface. The system ignored the message and continued normal processing.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRCMDFAILED : Interface [chars], CTR Command [chars] Failed, [chars] ([hex])

Explanation    A command that was sent from the system to the token-ring interface has failed to complete successfully.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRCMDFAILED2 : Interface [chars], CTR Command [chars] Failed, Code [hex]

Explanation    A command that was sent from the system to the token-ring interface has failed to complete successfully.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRINIT : Interface [chars], CTR Initialization Failed - [chars]

Explanation    The token-ring interface has failed one of its internal self-tests.

Recommended Action    Issue a clear interface command. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRLRCMDFAIL0 : Controller [dec], cmd ([dec]) failed ([hex]) count ([dec])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating and sending an error code to the requester.

Error Message  

%CBUS-3-CTRLRCMDFAIL1 : Controller [dec], cmd ([dec] [hex]) failed ([hex]) count ([dec])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating an error code to the requester.

Error Message  

%CBUS-3-CTRRAMTEST : Interface [chars], RAM Addressing Test Failed - [chars]

Explanation    The token-ring interface has failed its memory diagnostic tests.

Recommended Action    Issue a clear interface command. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRRSET : Interface [chars] failed to initialize

Explanation    The token-ring interface failed to insert into the Token Ring. The interface is placed into a reset state and will not automatically try to reinsert itself.

Recommended Action    Issue a clear interface command. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-CTRUCHECK : Interface [chars], Microcode Check Error

Explanation    The token-ring interface microcode has detected an unrecoverable error.

Recommended Action    Issue a clear interface command. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-DAUGHTER : Unit [dec], daughter controller [dec] failed [chars] test - interface disabled

Explanation    A hardware component has failed an internal diagnostic test. Test output and descriptions are as follows:

Unit [dec] (ranges 0-14)—Indicates the Multibus jumper setting for the ciscoBus controller, or a slot number in the Cisco 7000.

daughter controller [dec] (ranges 0-3)—Indicates the ciscoBus relative slot number (0 to 3, or in the Cisco 7000, 0 to 4) of the daughter card that failed the test.

failed [chars] test ([chars]= memd read, memd write)—If the failed test was memd read, the processor was able to write to shared ciscoBus buffer memory from the ciscoBus registers, but was unable to read back that memory through special commands to the daughter card.

If the failed test was memd write, writes to the memory device through the daughter card were not verified successfully with reads through the ciscoBus controller.

The daughter card under test responds successfully to some commands (otherwise the software would have received a DAUGHTER_NO_RSP message), but failed its memory device tests. The daughter card must be able to write to some memory device addresses; otherwise, it cannot respond to any commands.

Recommended Action    First ensure that the daughter controller card is properly seated in its Multibus and ciscoBus connectors. Next, swap daughter cards and check whether the error follows the daughter card or the slot. If the message recurs, call your technical support representative for assistance.

Error Message  

%CBUS-3-DAUGHTER_NO_RSP : Unit [dec], daughter [dec], not responding ([hex]) - disabled

Explanation    A hardware component failed an internal diagnostic test. Test output and descriptions of ranges are as follows:

Unit [dec] (ranges 0-14)—Indicates the Multibus jumper setting for the ciscoBus controller.

daughter controller [dec] (ranges 0-3)—Indicates the ciscoBus relative slot number (0 to 3, or in the Cisco 7000, 0 to 4) of the daughter card that failed the test.

The hardware of the daughter card was recognized across the ciscoBus backplane, but the daughter card did not respond to the first command that was issued to it.

This condition is a result of one of the following: the daughter card did not reset, or the microcode on the card is in a hung state, or the card cannot fully communicate across the ciscoBus backplane (cannot read or write shared MEMD or does not get the MALU_ATTENTION signal across the ciscoBus).

Recommended Action    First, ensure that the daughter card is properly seated in its Multibus and ciscoBus connectors. If the message recurs, call your technical support representative.

Error Message  

%CBUS-3-FCICMDFAIL0 : Controller [dec], cmd ([dec]) failed ([hex]) count ([dec])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating an error code to the requester. No action is required.

Error Message  

%CBUS-3-FCICMDFAIL1 : Controller [dec], cmd ([dec] [hex]) failed ([hex]) count ([dec])

Explanation    A command that was sent from the system to an interface processor has failed to complete successfully.

Recommended Action    The system recovered by generating and sending an error code to the requester. No action is required.

Error Message  

%CBUS-5-FDDICMD : '[chars]' is not supported on [chars]

Explanation    The issued command is not supported on this FDDI interface.

Recommended Action    No action is required.

Error Message  

%CBUS-3-FDDIRSET : Interface [chars], Error ([hex]) [chars] - fddi_reset()

Explanation    The specified hardware device did not respond appropriately to a request.

Recommended Action    Ensure that the specified hardware device is functioning and is configured correctly.

Error Message  

%CBUS-3-FDDIRSETU : Unit [dec], Error ([hex]) [chars] - fddi_reset()

Explanation    The specified hardware device did not respond appropriately to a request.

Recommended Action    Ensure that the specified hardware device is functioning and is configured correctly.

Error Message  

%CBUS-3-FSIPRSET : Interface [chars], Error ([hex]) [chars] - fsip_reset()

Explanation    An FSIP did not respond to a reset request from the RP.

Recommended Action    Check the FSIP electrical connections, cable, and ciscoBus connections. An FSIP microcode reload will be required. If the check of electrical connections reveals no problems and this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-HSSIRSET : Interface [chars], Error ([hex]) [chars] - hssi_reset()

Explanation    A hardware component did not respond to a reset command.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-INITERR : Interface [dec], Error ([hex]), idb [hex] [dec] [chars] - cbus_init()

Explanation    The switch processor or ciscoBus controller has signalled an error while processing a packet or selecting an interface. This message indicates a software problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-INTR : Interface [dec], idb [hex] [dec] [chars] - cbus_interrupt()

Explanation    The switch processor or ciscoBus controller has returned an invalid value.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-4-NOCOOKIE : [chars]-[dec] controller missing configuration data - disabled

Explanation    The controller type was derived from a hardware probe. The controller number indicates the ciscoBus relative slot number. This message indicates a hardware error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-OUTHUNG : [chars]: tx[char] output hung ([hex] - [chars]), [chars]

Explanation    A transmission attempt on an interface has failed. The interface might not be attached to a cable or there might be a software problem.

Recommended Action    Check that the interfaces are all connected to the proper cables. If improper connection is not the problem, contact your Cisco technical support representative for assistance.

Error Message  

%CBUS-3-POLLFAIL : Interface [chars] failed to respond, debug info follows

Explanation    A token-ring interface card failed to respond to periodic polling. This can indicate a software or hardware problem. See "CBUS-3-POLLFAILDAT" for the syntax of this message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-POLLFAILDAT : Int [dec]: [hex] [hex] [hex] [hex] [hex] [hex]

Explanation    This is the debugging information for the "CBUS-3-POLLFAIL" error.

Recommended Action    This is a debug message only. No action is required.

Error Message  

%CBUS-3-POTSTAT : Out of buffers--losing status information for POTENT on VIP card

Explanation    An internal software resource has been exhausted.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-RESETNXI : Reset of removed interface [hex] ([chars])

Explanation    An interface reset was attempted on an interface that had been removed from the router. This message appears if you use the shutdown command to bring down a previously removed interface.

Recommended Action    No action is required.

Error Message  

%CBUS-4-RSETFAIL : Interface [chars] failed to reset properly in [chars], code [hex]

Explanation    An interface reset command has failed. This may be a software or hardware problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-SERRSET : Interface [chars], Error ([hex]) [chars] - serial_reset()

Explanation    A software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-TESTFAIL : Unit [dec], failed [chars] test - interface disabled

Explanation    A hardware component has failed an internal diagnostic test.

Recommended Action    Check the switch settings on the interface cards. Check for proper unit numbers. Reset the cards. Replace the malfunctioning device.

Error Message  

%CBUS-3-TXALLOC : Error ([hex]) tx_allocate - cbus_init()

Explanation    A hardware device did not respond appropriately to a request.

Recommended Action    Ensure that the device is functioning and is configured correctly.

Error Message  

%CBUS-3-TXSTARTPENDACTIVE : [chars] ustatus: [chars] ([hex]), [hex] [hex] [hex] [hex]

Explanation    This message provides debugging information when an IP panics.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CBUS-3-UNKENC : Interface [chars], unknown encaps type [hex]

Explanation    A packet was received from the CIP with an unknown encapsulation type. The packet will be dropped.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CBUS-3-UNKNOWN : [chars] ustatus: [chars] ([hex]), [hex] [hex] [hex] [hex]

Explanation    This message provides debugging information when an IP panics.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CCH323 Messages

The following are Call Control for H323 error messages.

Error Message  

%CCH323-3-BAD_IP_ADDRESS : [chars]: illegal destination [chars]

Explanation    The IP address that was passed from the Call Control API in the call setup request is invalid.

Recommended Action    Check the dial-peer configuration for the dial peer that matches the called party number. Ensure that the session target field contains a valid IP address or DNS name.

Error Message  

%CCH323-3-CALL_SETUP_FAILED : [chars]: call setup failed

Explanation    The call setup request has failed.

Recommended Action    Verify that the remote destination identified by the IP address is reachable.

Error Message  

%CCH323-3-CANNOT_ALLOCATE_CALL_INFO : [chars]: cannot allocate call info data structure

Explanation    Allocation of the CCH323 call information structure has failed. This condition may occur because the system memory pool is exhausted.

Recommended Action    This call will be terminated because of a lack of resources.

Error Message  

%CCH323-3-CANNOT_ALLOCATE_CCB : [chars]: cannot allocate call control block

Explanation    Allocation of the CCH323 call control block has failed. The allocation failure is possibly caused by an exhausted system memory pool.

Recommended Action    This can be a catastrophic error. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CCH323-3-CANNOT_FIND_CCB : [chars]: cannot find CCH323 call control block based on callID [dec]

Explanation    The system cannot find a CCH323 call control block based on the specified call ID. This is an indication that some events have occurred out of sequence.

Recommended Action    No action is required.

Error Message  

%CCH323-3-CANNOT_INSERT_CCB : [chars]: cannot insert control block [hex] to tree

Explanation    Insertion of the specified CCH323 call control block to the RBTree has failed. This condition can be related to a corrupted RBTree.

Recommended Action    This can be a catastrophic error. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CCH323-3-CCAPI_CONNECT_ERROR : [chars]: cc_api_call_disconnected returns [dec]

Explanation    An error is returned when CCH323 attempts to call cc_api_call_connected.

Recommended Action    No action is required.

Error Message  

%CCH323-3-CCAPI_DISCONNECT_ERROR : [chars]: cc_api_call_disconnected returns [dec]

Explanation    An error is returned when CCH323 attempts to call cc_api_call_disconnected.

Recommended Action    No action is required.

Error Message  

%CCH323-3-CCH323_RSCMON_SETUP_FAILURE : [chars][dec]

Explanation    A failure was encountered in setting up the monitoring of H.323 resources.

Recommended Action    Power-cycle the system. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CCH323-3-CCH323_UNKNOWN_EVENT : unknown event [hex]

Explanation    An unknown CCH323 event has occurred.

Recommended Action    No action is required.

Error Message  

%CCH323-2-E164_LENGTH_IS_NOT_SUPPORTED : [chars]: E164 address length [dec] is not supported

Explanation    A packet was received with an E.164 address of a length that is not supported.

Recommended Action    Report this event immediately to your Cisco technical support representative.

Error Message  

%CCH323-2-GTKP_UNREGSTR : Gatekeeper [chars] requested unregister from Gateway [chars]

Explanation    The gatekeeper has requested that it be unregistered from Gateway.

Recommended Action    Verify that this is an intended request. If it is not, copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CCH323-2-GTWY_REGSTR_FAILED : Gateway [chars] failed to register with Gatekeeper [chars] even after [dec] retries

Explanation    A gateway has failed to register with the gatekeeper.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CCH323-2-GTWY_REGSTR_FAILED_ALT_GK : Gateway [chars] failed attempt to register with Alternate Gatekeeper [chars]

Explanation    A gateway has failed in an attempt to register with an alternate gatekeeper.

Recommended Action    Report this error message immediately to your Cisco technical support representative. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CCH323-2-GTWY_UNREGSTR : Gateway [chars] unregistered from Gatekeeper [chars]

Explanation    A gateway has unregistered from the gatekeeper.

Recommended Action    Verify that this is an intended request. If it is not, copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message 

%CCH323-3-OSS_INIT_FAILED : [chars]: OSS init failure: errno = [dec]

Explanation    OSS ASN1 initialization has failed.

Recommended Action    This can be a catastrophic occurrence. Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CCH323-6-REGSTR : Gateway [chars] registered with Gatekeeper [chars]

Explanation    A gateway has registered with the gatekeeper.

Recommended Action    No action is required.

Error Message  

%CCH323-3-STRCALLHISFAIL :
cch323_store_call_history: [chars]

Explanation    An attempt to insert an active H323 call record into the call history list has failed.

Recommended Action    No action is required.

CCPROXY Messages

The following are H.323 proxy error messages.

Error Message 

%CCPROXY-3-NOBLOCK_EVENT : During initialization of proxy, [chars]: cannot allocate event block\n

Explanation    During the initialization of a proxy, an event block could not be allocated.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CCPROXY-3-NOCCAPI_INTERFACE : CCAPI new interface is not created in [chars]\n

Explanation    The new call-control API interface was not created.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CCPROXY-3-NOCCB_FROM_CALLID : No call-control-block is found in [chars] for ([hex]).\n

Explanation    No call-control block was found.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CCPROXY-3-UNREGISTERED_BY_GK : H.323 Proxy registration is being removed by Gatekeeper [chars]\nCheck "show proxy h323 status" for details.

Explanation    The H.323 proxy registration is being removed by the gatekeeper. For more details, enter the show proxy h323 status command.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CDM Messages

The following are Cable Data Modem (CDM) error messages.

Error Message  

%CDM-6-CHANNELDOWN : Channel(vpi=[dec]) on [chars], changed state to down

Explanation    The signaling connection to this system has gone down.

Recommended Action    This is an informational message only. No action is required.

Error Message  

%CDM-6-CHANNELUP : Channel(vpi=[dec]) on [chars], changed state to up

Explanation    The signaling connection to this system has been activated.

Recommended Action    This is an informational message only. No action is required.

Error Message  

%CDM-6-CHANNELUPPENDING : Channel(vpi=[dec]) on [chars], changed state to up pending

Explanation    The local interface is up, but the remote interface or system does not respond. It is probably not connected or is powered down.

Recommended Action    This is an informational message only. No action is required.

Error Message  

%CDM-3-CONFIG : Interface [chars] must be ACIP to run cable application

Explanation    The named interface is not an ATM Cable Interface Processor interface.

Recommended Action    An ATM Cable Interface Processor is required to run the CDM application. Verify that an ATM Cable Interface Processor is installed in the system.

Error Message  

%CDM-3-INIT : ACIP required to run this Cisco IOS image

Explanation    No ATM Cable Interface Processor is installed in the system.

Recommended Action    An ATM Cable Interface Processor is required to run the cable data modem (CDM) application. Install an ATM Cable Interface Processor.

Error Message  

%CDM-6-MODEMDOWN : Modem(vci=[dec]) on [chars], changed state to down

Explanation    A modem was disconnected from the system.

Recommended Action    No action is required. This message is informational only.

Error Message  

%CDM-6-MODEMUP : Modem(vci=[dec]) on [chars], changed state to up

Explanation    A new modem was connected to the system.

Recommended Action    No action is required. This message is informational only.

CDP Messages

The following are Cisco Discovery Protocol (CDP) error messages.

Error Message  

%CDP-4-DUPLEX_MISMATCH : duplex mismatch discovered on [chars] ([chars]), with [chars] [chars] ([chars]).

Explanation    CDP has discovered a mismatch of duplex configuration.

Recommended Action    Configure the interfaces so they are both running at the same duplex (full- or half-duplex).

Error Message  

%CDP-4-NATIVE_VLAN_MISMATCH : Native VLAN mismatch discovered on [chars] ([dec]), with [chars] [chars] ([dec]).

Explanation    CDP has discovered a mismatch of native VLAN configuration.

Recommended Action    Configure the interfaces to use the same native VLAN.

CE3 Messages

The following are CE3 port adapter error messages.

Error Message  

%CE3-3-BADMSG : Received unexpected mailbox message (id = [dec])

Explanation    An unexpected message was received from the CE3 firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CE3-2-CE3FWCRASHED : CE3 F/W crashed: [hex] - VIP reset

Explanation    The CE3 firmware did not update the software watchdog.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-2-CE3FWCRASHEDINFO : [hex] [hex] [hex] [hex]

Explanation    The CE3 firmware did not update the software watchdog.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-CONFIGURE : Failed to configure [dec] interfaces in bay [dec], shutting down bay

Explanation    The CE3 hardware has failed. Some components on the board failed to initialize.

Recommended Action    Replace the CE3 port adapter.

Error Message  

%CE3-1-DISCOVER : Found [dec] interfaces in bay [dec], shutting down bay

Explanation    The CE3 hardware has failed. Some components on the board failed to initialize.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-DWNLDFAIL : Microcode to slot [dec]

Explanation    An attempt to download firmware into the CE3 port adapter has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-ENABLEFAIL : [chars] could not be enabled by [chars]

Explanation    The restart has failed to enable the interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-ERROR : [chars]

Explanation    This message provides general error information.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-INITFAIL : Slot [dec] firmware init ([chars])

Explanation    The CE3 firmware initialization has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-INITFAILP : [chars] init failed at [chars]

Explanation    The CE3 firmware initialization has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-LOVEFAIL : [chars]: failed to send [chars] love letter

Explanation    A "love letter" (operating status or configuration message) was not sent to the RSP.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-MBOXRECV : Failed to receive reply [dec] from bay [dec] firmware

Explanation    A message was not received from the CE3 firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-MBOXRECVP : Failed to receive reply [dec] to [chars] driver firmware

Explanation    A port-related message was not received from the CE3 firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-MBOXSEND : Failed to send msg [dec] to bay [dec] firmware

Explanation    A message was not sent to the CE3 firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-MBOXSENDP : Failed to send msg [dec] to [chars] driver firmware

Explanation    A port-related message was not sent to CE3 firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-NOACC : [chars] - Accumulator is not available

Explanation    An invalid Tx accumulator has been detected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-3-NOTFREEDM : Slot [dec] device ID seen as [hex], expected [hex] (FREEDM)

Explanation    An attempt to detect the HDLC controller on the CE3 has failed.

Recommended Action    Replace the CE3 port adapter.

Error Message  

%CE3-3-NOTPLX : Slot [dec] device ID seen as [hex], expected [hex] (PLX9060)

Explanation    The PLX 9060 was not detected on the CE3.

Recommended Action    Replace the CE3 port adapter.

Error Message  

%CE3-1-NOTREADY : Slot [dec] for microcode download

Explanation    An error was detected on the communication path between the VIP and the CE3 port adapters.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-2-NOVC : [chars]: packet received for unknown VC [dec]

Explanation    The virtual channel encapsulation is corrupted.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-RESTARTFAIL : [chars] could not be reset by [chars]

Explanation    The restart has failed to reset the interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-STARTFAIL : [chars] could not be enabled by [chars]

Explanation    The restart has failed to enable the interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CE3-1-STOPFAIL : [chars] could not be disabled by [chars]

Explanation    The shutdown failed to disable the interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CES Messages

The following are Circuit Emulation Service (CES) error messages.

Error Message  

%CES-2-INTERNAL_CRITICAL : [chars]

Explanation    The CES subsystem has encountered an internal software error. The error message contains text that can be used to help identify the nature of the problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CES-3-INTERNAL_ERROR : [chars]

Explanation    The CES subsystem has encountered an internal software error. The error message contains text that can be used to help identify the nature of the problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message  

%CES-4-INTERNAL_WARNING : [chars]

Explanation    The CES subsystem has encountered an internal software error. The error message contains text that can be used to help identify the nature of the problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative and provide the representative with the gathered information.

CHOPIN Messages

The following are Cisco Chopin error messages.

Error Message  

%CHOPIN-3-BADADDR : chopin_little_endian_addr: Attempted conversion of invalid address ([hex])

Explanation    A software error has occurred during an attempt to determine PCI device addressing.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADADDR2 : chopin_big_endian_addr: Attempted conversion of invalid address ([hex])

Explanation    A software error has occurred during an attempt to determine PCI device addressing.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADBAYDEV : get_pci_dev_num: Invalid bay ([dec]) or device number offset ([dec])

Explanation    A software error has occurred during an attempt to determine PCI device addressing.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADDEVNO : pas_get_device_subunit: Invalid PCI device number: [dec]

Explanation    A software error occurred during an attempt to determine PCI device addressing.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADNV : Detected invalid NVRAM size: [dec] bytes

Explanation    The detected size of NVRAM is not one of the supported sizes. The NVRAM may be faulty.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADPA : Invalid Port Adaptor type ([dec]) reported for mainboard

Explanation    The virtual port adapter type that was derived from the main board type is not supported. One reason for this condition is that this main board is a new main board type and the software release that is running on the system does not support the new main board type.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADPCIRD : PCI Configuration Read Cycle Failed for bus [dec], Device [dec], function [dec], register [dec]

Explanation    A PCI Bus Configuration Read cycle has failed. The main board needs to be replaced.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-BADPCIWR : PCI Configuration Write Cycle Failed for bus [dec], Device [dec], function [dec], register [dec]

Explanation    A PCI Bus Configuration Write cycle has failed. The main board needs to be replaced.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-INITFAIL : CHOPIN (bay [dec]), Init Failed at [chars] - line [dec] arg [hex]

Explanation    The port adapter has failed to complete its hardware initialization.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-NOMAC : Can't allocate MAC address for interface [int]/[int]

Explanation    A MAC address cannot be allocated for the specified interface because all available MAC addresses for the system have been allocated.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-6-NOTDMBP : No TDM backplane is supported on slot [dec].

Explanation    A TDM backplane is not supported on the specified slot; therefore, DS0 inter slot cannot be cross-connected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CHOPIN-6-NOTSUPPORT : Voice PA is not supported in this platform.

Explanation    The port adapter is not supported on this platform.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-NVERASEFAIL : Failed to erase config due to internal error

Explanation    The password protection feature has failed to erase a configuration because of an internal error.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CHOPIN-1-OVERTEMP : System detected OVERTEMPERATURE condition.
Putting the system in Power save mode and going to rommon.
Please resolve cooling problem and restart system!\n

Explanation    The environmental monitor has detected a high-temperature condition.

Recommended Action    Make sure that the room temperature is within recommended ranges and that air flow to the card is not blocked. If this condition persists, the environmental monitor might shut down the system. If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message  

%CHOPIN-6-RXDFILLFAIL : CHOPIN (bay [dec]), Data rx ring refill failed: rxd_fill_fail=[dec]

Explanation    The port adapter has failed to refill the data Rx ring.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-6-RXVFILLFAIL : CHOPIN (bay [dec]), Voice rx ring refill failed: rxv_fill_fail=[dec]

Explanation    The port adapter has failed to refill the voice Rx ring.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-1-STARTFAIL : [chars] channel not enabled

Explanation    A software or hardware error has occurred. The Chopin serial interface is not responding to the commands that are used to initialize it.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-TDMFAIL : CHOPIN-TDM, access failed at [chars] - line [dec], arg1=[dec],arg2=[dec]

Explanation    The port adapter has failed to access the TDM switch.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-TSBUSY : CHOPIN (bay [dec]), TDM timeslot is busy: ST=[dec]/TS=[dec]

Explanation    The port adapter has failed to grant a cross-connect setup request.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-TSNONBUSY : CHOPIN (bay [dec]), TDM timeslot is non busy: ST=[dec]/TS=[dec]

Explanation    The port adapter has failed to grant a cross-connect teardown request.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-5-TXVFULL : CHOPIN (bay [dec]), Voice tx ring is full: dma_done=[dec], last_dma_done=[dec]

Explanation    The voice Tx ring for the port adapter is full.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message 

%CHOPIN-3-UNEXPEVENT : CHOPIN (bay [dec]), received an unexpected event=[hex]

Explanation    The port adapter has received an unexpected event from the firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

CHOPIN_MAINBOARD_ASYNC_PQII Messages

The following are Chopin Main Board Asynchronous Driver error messages.

Error Message 

%CHOPIN_MAINBOARD_ASYNC_PQII-3-NOMEMORY : No memory for [chars] of unit [dec]

Explanation    The router does not have enough memory to perform the requested function.

Recommended Action    Consider adding more shared memory. Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.