LCCOREDUMP Messages
The following are GRP line card core dump subsystem messages.
Error Message
%LCCOREDUMP-3-BADCLOSE
: Can't close slave core socket for slot [dec]
Explanation The system just finished dumping a core file. It tried to close this file on the remote
system and failed.
Recommended Action Debug network connections and user privileges.
Error Message
%LCCOREDUMP-3-ILLEGALREQ
: Cannot process coredump request for slot [dec]
Explanation A line cannot not directly send a core dump request.
Recommended Action Gather information about the state of the card. Copy the message exactly as it
appears on the console or in the system log. Research and attempt to resolve the issue using the tools
and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities
will supply clarifying information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCCOREDUMP-3-ILLPAK
: Coredump packet received from slot [dec] (not in dump state)
[hex] [hex] [hex] [hex]\n[hex] [hex] [hex] [hex]\n[hex] [hex] [hex] [hex]
[hex] [hex] [hex] [hex]
Explanation A core dump packet from a card that should not be dumping a core dump packet has
arrived at the RP.
Recommended Action Gather information about the state of all cards, copy the error message exactly
as it appears on the console or in the system log, contact your Cisco technical support representative,
and provide the representative with the information you have gathered.
Error Message
%LCCOREDUMP-3-ILLTD
: Testdump not allowed on primary GRP
Explanation The user has attempted to run a line card core dump test for a primary GRP. This action
is not allowed.
Recommended Action Do not run a line card core dump test for a primary GRP.
Error Message
%LCCOREDUMP-3-NOMCP
: Cannot malloc memory for mbus core dump message to slot [dec]
Explanation The system is trying to write a core dump file to a remote system. It could not allocate
memory to create the message to send to start the dump on the card.
Recommended Action Add memory.
Error Message
%LCCOREDUMP-4-NOMEM
: Could not allocate memory for [chars]
Explanation Memory allocation for a core dump parameter has failed.
Recommended Action Gather information about memory usage. Copy the message exactly as it
appears on the console or in the system log. Research and attempt to resolve the issue using the tools
and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities
will supply clarifying information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCCOREDUMP-3-NOPAK
: No packet on queue ([hex] [dec])
Explanation A core dump packet from a card that should not be dumping core arrived at the RP.
Recommended Action Gather information about the state of all cards and file a bug.
Error Message
%LCCOREDUMP-3-NOQUEUE
: Cannot create queue to receive dump packets for slot [dec]
Explanation The system is trying to write a core dump file to a remote system. It could not create a
queue to hold dump data coming from the card.
Recommended Action Add memory.
Error Message
%LCCOREDUMP-4-TIMEOUT
: [chars] ([hex] [dec])
Explanation The system is trying to write a core dump file, but the RP timed out waiting for data
from the card.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LC_CT3 Messages
The following are line card error messages for the Channelized T3 controller.
Error Message
%LC_CT3-1-INITBERT
: BERT port [dec] init failed ([chars])
Explanation A T1 BERT initialization failure has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs. data
that may provide information to determine the nature of the error. If you cannot determine the nature
of the error from the error message text or from the show tech-support output, contact your Cisco
technical support representative, and provide the representative with the information you have
gathered.
Error Message
%LC_CT3-1-INITFAIL
: CT3 linecard init ([chars])
Explanation The CT3 could not be initialized.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CT3-1-INITFAILP
: [dec] init failed at [chars]
Explanation The CT3 port could not be initialized.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CT3-3-NOTFOUND
: [chars] not found for port [dec].
Explanation A software or hardware error has occurred. The specified object was not found.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CT3-3-UNEXPECTEDCASE
: Unexpected case ([dec])
Explanation An unexpected case has occurred in the CT3 line card software switch statement.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LC_CX3 Messages
The following are error messages for the CX3 line card.
Error Message
%LC_CX3-3-BMA_ERR
: Packet with length 0 received by FrFab BMA:
[chars]
Explanation The FrFab BMA has encountered a packet with length of zero, and forwarded it to the
PLIM so that it could be logged.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-1-INITFAIL
: CX3 linecard init ([chars])
Explanation An attempt to initialize the CX3 has failed.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-4-INVCALL
: Invalid call ([chars]: [dec])
Explanation A software error was detected.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-2-KEEPALIVE_FAILURE
: PLIM Keepalive failed (freedm [int]) - plim reset
Explanation A PLIM keepalive failure was detected.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-3-MBOXACCESS
: Mailbox[[dec]] in use by process [chars], timeout by process
[chars]
Explanation A process could not obtain access to the PLIM mailbox on an Internet router CX3 line
card because the PLIM mailbox was locked by another process.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log. Enter the following commands to gather data that may provide information to determine the
nature of the error: exec slot slot-number show controllers tofab mailbox, exec slot slot-number
show controllers frfab mailbox, exec slot slot-number show plim tofab mailbox, exec slot
slot-number show plim frfab mailbox, with slot-number being the slot number of the CX3 line
card. Call your Cisco technical support representative. Research and attempt to resolve the issue
using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools
and utilities will supply clarifying information. Search for resolved software issues using the Bug
Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require
assistance, open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-3-NOBUFFERS
: Message dropped from [chars]: No buffers available
Explanation There are not enough buffers available for messages coming from the PLIM on an
Internet router CX3 line card.
Recommended Action Try shutting down debugs on the PLIM CPU or reloading the card. If the
problem persists, copy the error message exactly as it appears on the console or in the system log.
Issue the show tech-support command to gather data that may help identify the nature of the error.
If you cannot determine the nature of the error from the error message text or from the show
tech-support command output, contact your Cisco technical support representative, and provide the
representative with the information you have gathered.
Error Message
%LC_CX3-3-PLIMCON
: Message dropped from [chars]: No buffers available
Explanation There are too many messages coming from the PLIM on an Internet router CX3 line
card. There are no more buffers on the line card to handle these messages.
Recommended Action Try shutting down debugs on the PLIM CPU or reloading the card. If the
problem persists, copy the error message exactly as it appears on the console or in the system log.
Issue the show tech-support command to gather data that may help identify the nature of the error.
If you cannot determine the nature of the error from the error message text or from the show
tech-support command output, contact your Cisco technical support representative, and provide the
representative with the information you have gathered.
Error Message
%LC_CX3-2-PLIM_CPU_CRASHED
: PLIM CPU [chars] - plim reset
Explanation PLIM CPU software did not respond to a heartbeat message.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-1-PLIM_CPU_ERR
: [chars]: [chars]
Explanation The PLIM CPU reported a system message.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-4-THROTTLE
: Packet throttling activated due to congestion
Explanation Packet throttling has been started in the PLIM due to excessive buffer overruns.
Throttling eliminates overruns, which allows high priority packets such as link control and
keepalives to be preserved and to pass through. This mechanism prevents interfaces from toggling
up and down.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-4-UNEXPECTEDCASE
: Unexpected case ([dec])
Explanation An unexpected case was encountered in the line card software switch statement.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_CX3-4-UNEXPECTEDCOND
: Unexpected condition [chars] [dec]
Explanation An unexpected condition was encountered in the line card software.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LC_DMLP Messages
The following are line card DMLP messages.
Error Message
%LC_DMLP-4-BUNDLENULL
: Unexpected null bundle in [chars], searching for [chars]
Explanation A software error has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_DMLP-1-IDBCREATEFAIL
: Could not create bundle hwidb in [chars]
Explanation The system is out of resources.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_DMLP-4-IDBNULL
: Unexpected null hwidb in [chars]
Explanation A software error has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_DMLP-4-IDBWRONG
: The requested hwidb is null or wrong type in [chars], vc [dec]
Explanation A software error has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LC_DMLP-4-NLINKS
: The bundle had an unexpected number of links in [chars], nlinks
[dec]
Explanation A software error has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LCDS3 Messages
The following are error messages for the DS3 line card.
Error Message
%LCDS3-1-ALLOCFAIL
: [dec]/[dec][chars] allocation failure
Explanation Memory could not be allocated for the DS3.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCDS3-0-BADPORT
: [chars] [dec]
Explanation A very high rate of bad packets was received on the specified port. This situation can
happen because of port misconfiguration, especially for mismatched DSU subrates (most common
with Kentrox). The port is shut down for this reason so that the line card is not overwhelmed with
these bad packets.
Recommended Action Verify that the configuration is correct and matching on both ends of the
connection. These include the clock source (one end line, the other internal), DSU (mode and
subrate), and encapsulation. Also verify the physical condition on the line (run BERT or other tests),
signal strength, and cable length.
Error Message
%LCDS3-3-BMAENG
: [chars] HDLC, [chars] [chars][chars]. (src=[hex], det1=[hex],
det2=[hex])
Explanation Hardware errors have occurred in the HDLC BMA engine.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log. Run diagnostics on the line card in slot x. If diagnostics pass, contact your Cisco technical
support representative, and provide the representative with the information you have gathered.
Error Message
%LCDS3-3-BMAPAR
: [chars] HDLC, [chars]. BMA_DATA[3:0]=[hex]. (src=[hex],
det1=[hex], det2=[hex])
Explanation A parity error has occurred on the HDLC ASIC BMA engine.
Recommended Action Run diagnostics on the line card in the specified slot. Copy the message exactly
as it appears on the console or in the system log. Enter the show tech-support command to gather
data that may help identify the nature of the error. Research and attempt to resolve the issue using
the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and
utilities will supply clarifying information. Search for resolved software issues using the Bug
Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require
assistance, open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCDS3-3-HDLCENG
: [chars] HDLC, [chars]. [chars], port [dec]. (src=[hex],
det1=[hex], det2=[hex])
Explanation HDLC engine hardware errors have occurred.
Recommended Action Run diagnostics on the line card in the specified slot. Copy the message exactly
as it appears on the console or in the system log. Enter the show tech-support command to gather
data that may help identify the nature of the error. Research and attempt to resolve the issue using
the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and
utilities will supply clarifying information. Search for resolved software issues using the Bug
Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require
assistance, open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCDS3-0-INITFAIL
: initialization failure for slot [dec]
Explanation The DS3 line card could not be initialized.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message .
%LCDS3-2-LOWSIG
: low DS3 signal in port [dec]
Explanation A low signal condition was detected in the specified DS3 port.
Recommended Action Verify the DS3 line conditions.
Error Message
%LCDS3-3-NOHWIDB
: [dec]/[dec][chars] hardware IDB is missing
Explanation DS3 port hardware IDB is missing.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCDS3-3-SRAMPAR
: [chars] HDLC, [chars]. [chars]=[hex][chars]. (src=[hex],
det1=[hex], det2=[hex])
Explanation A parity error has occurred on the HDLC ASIC SRAM.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCDS3-4-UNKNOWNPARAM
: [dec]/[dec][chars] parameter value is unknown
Explanation An IPC command parameter is unknown.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LDP Messages
The following are Label Distribution Protocol (LDP) messages.
Error Message
%LDP-4-ADV
: Label advertisement mode (DU/DoD) mismatch with peer [chars], resolved
to [chars].
Explanation A disagreement regarding the label distribution mode to be used with an LDP peer has
been resolved according to the LDP protocol specification. For LCATM links when there is a
disagreement the protocol specification requires that the session use Downstream on Demand mode;
for frame-based links when there is disagreement the protocol requires that the session use
Downstream Unsolicited mode.
Recommended Action This is an informational message. The system will recover from this situation
by terminating the TDP session and attempting to establish a new session with the peer. If this
message occurs repeatedly, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LDP-5-GR
: [chars]
Explanation An informational LDP notice was generated for a "graceful restart" event.
Recommended Action No action is required.
Error Message
%LDP-3-MALFORMED_MSG
: peer [chars]; format error for msg type [hex]
Explanation A malformed LDP message has been received from an LDP peer.
Recommended Action This is an informational message. The system will recover from this situation
by terminating the TDP session and attempting to establish a new session with the peer. If this
message occurs repeatedly, copy the error message exactly as it appears on the console or in the
system log, contact your Cisco technical support representative, and provide the representative with
the information you have gathered.
Error Message
%LDP-5-NBRCHG
: [chars] Neighbor [chars] is [chars]
Explanation An LDP neighbor has either come up or gone down. The error message text describes
the change for it.
Recommended Action This informational message normally appears as routers and LDP neighbors go
up or down. However, unexpected neighbor loss might indicate high error rates or high packet loss
in the network and should be investigated.
Error Message
%LDP-4-PTCL
: peer [chars], [chars]
Explanation A violation of the LDP protocol by an LDP peer has been detected.
Recommended Action This is an informational message. The system will recover from this situation
by terminating the TDP session and attempting to establish a new session with the peer. If this
message occurs repeatedly, copy the error message exactly as it appears on the console or in the
system log, contact your Cisco technical support representative, and provide the representative with
the information you have gathered.
Error Message
%LDP-3-UNKNOWN_MPLS_APP
: [chars] [chars] message from [chars]; [chars];
Explanation An LDP message with an unknown label type or address family has been received from
a peer. The message has been dropped.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LCE3 Messages
The following are line card E3 messages.
Error Message
%LCE3-1-ALLOCFAIL
: [dec]/[dec][chars] allocation failure
Explanation Memory could not be allocated for the E3 port.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-0-BADPORT
: [chars] [dec]
Explanation A very high rate of bad packets was received on the specified port. This situation can
happen because of port misconfiguration (most common with Kentrox). The port is shut down for
this reason so that the line card is not overwhelmed with these bad packets.
Recommended Action Verify that the configuration is correct and matching on both ends of the
connection. These include the clock source (one end line, the other internal), DSU mode, and
encapsulation. Also verify the physical condition on the line (run BERT or other tests), signal
strength, and cable length.
Error Message
%LCE3-3-BMAENG
: [chars] HDLC, [chars] [chars][chars]. (src=[hex], det1=[hex],
det2=[hex])
Explanation Hardware errors have occurred on the HDLC BMA engine.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-3-BMAPAR
: [chars] HDLC, [chars]. BMA_DATA[3:0]=[hex]. (src=[hex],
det1=[hex], det2=[hex])
Explanation A parity error has occurred on the HDLC ASIC BMA engine.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-3-HDLCENG
: [chars] HDLC, [chars]. [chars], port [dec]. (src=[hex],
det1=[hex], det2=[hex])
Explanation Hardware errors have occurred on the HDLC engine.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-0-INITFAIL
: initialization failure for slot [dec]
Explanation The E3 line card could not be initialized.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-2-LOWSIG
: low E3 signal in port [dec]
Explanation A low signal condition was detected in the specified E3 port.
Recommended Action Verify the E3 line conditions.
Error Message
%LCE3-3-NOHWIDB
: [dec]/[dec][chars] hardware IDB is missing
Explanation The E3 port hardware IDB is missing.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-3-SRAMPAR
: [chars] HDLC, [chars]. [chars]=[hex][chars]. (src=[hex],
det1=[hex], det2=[hex])
Explanation A parity error has occurred on the HDLC ASIC SRAM.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCE3-4-UNKNOWNPARAM
: [dec]/[dec][chars] parameter value is unknown
Explanation An IPC command parameter is unknown.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
LCFE Messages
The following are Fast Ethernet line card messages.
Error Message
%LCFE-6-CAM_ADD
: Failed to add address [enet] to CAM
Explanation An entry could not be added to the CAM MAC address filter.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-4-CAM_DONE_ITER
: CAM [chars]: wait for DONE exceeded [dec] iterations
Explanation An LC Fast Ethernet Rx Translator CAM DONE bit was not reset to 1 on a write or read
within the given number of iterations.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-4-CAM_DONE_TIME
: CAM [chars]: wait for DONE exceeded timeout ([dec] ms)
Explanation An LC Fast Ethernet Rx Translator CAM DONE bit was not reset to 1 on a write or read
within the given timeout period.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-6-CAM_EXCEEDED
: [dec] entries to add > [dec] entries available
Explanation An entry could not be added to the CAM MAC address filter.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-6-CAM_INIT
: HW MAC address filter (CAM) init failed: CAM disabled
Explanation The CAM hardware containing the MAC address filter has failed.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-6-CAM_REMOVE
: Failed to remove address [enet] from CAM
Explanation The system has failed to remove an entry from the CAM MAC address filter.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-3-FE_MAC_INTR
: MAC has detected unexpected interrupt
Explanation The LC Fast Ethernet MAC has detected an unexpected error interrupt.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-3-FE_RX_MICE
: MICE not initialized
Explanation The LC Fast Ethernet Mice FPGA could not be loaded.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-1-INITFAIL
: LCFE([dec]/[dec]), initialization timeout failure
Explanation The LC Fast Ethernet hardware could not be initialized.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-6-LINE_STATE
: Line state [chars]
Explanation A line state error was detected or fixed as specified in the message.
Recommended Action Check the cable connections. A local Rx cable must be connected to the remote
Tx cable and vice versa.
Error Message
%LCFE-4-OP
: error: [chars]
Explanation A line card Fast Ethernet driver general operation error has occurred.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-4-RPCMD
: [chars] command error: [chars]
Explanation The line card Fast Ethernet driver has encountered RP command errors.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-6-RX_LOS
: [chars] RX Loss of Signal
Explanation An Rx loss of signal error was detected or fixed as specified in the message.
Recommended Action Check the cable connections. A local Rx cable must be connected to the remote
Tx cable and vice versa.
Error Message
%LCFE-3-RX_TRANS_INTR
: RX FPGA has detected SRAM Parity Error
Explanation The LC Fast Ethernet Rx Translator FPGA has detected an SRAM parity error.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-3-RX_TX_TRANS
: RX/TX FPGA not initialized
Explanation The LC Fast Ethernet Rx/Tx Translator FPGA could not be loaded.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that may help identify the nature of the error.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet at
http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical
support representative and provide the representative with the information you have gathered.
Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of
the show logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message
%LCFE-3-SOP
: [chars]. Source=[hex] [chars], halt_minor0=[hex] [chars]
Explanation The LC Fast Ethernet SOP has encountered hardware errors.
Recommended Action Copy the message exactly as it ap