Table Of Contents
Dual Redundant Internal Power Supply: System Management
Dual Redundant Internal Power Supply: System Management
This document describes the system management and troubleshooting commands for the Cisco AS5300 Dual Redundant Internal Power Supply feature. In general, this document also applies to the redundant power supply feature available for the Cisco 3600 series and certain other Cisco products. For more information, see the "Platforms" section. The following topics are included:
Note
This product and document are still in development. Some portions of this document might not be complete and are subject to change.
Feature Summary
The dual redundant internal power supply feature for the Cisco AS5300 provides optional DC or AC dual internally-redundant power supplies for the Cisco AS5300 chassis. Two versions are available:
•
Dual AC input, 300-watt—The dual redundant AC power supply for the Cisco AS5300 has separate power cords.
•
Dual DC input, 300-watt
Cisco IOS software commands manage the power supply, providing the following capability:
•
Designate SNMP trap (message) address
•
Enable/disable sending SNMP traps
•
Send SNMP traps and alarms when a failure or recovery from the unit is detected
•
Display of the SNMP environment monitor statistics
There are no configuration commands to enable the dual redundant internal power supply event monitoring; it is ON by default. However, SNMP traps can be enabled for environment events so that Cisco IOS software sends traps based on power supply failure or recovery events. The only configuration required is to turn on the sending of SNMP traps for environment monitoring and to specify an SNMP server to which the traps are sent. Events and status are displayed through console messages and the show environment command.
Cisco AS5300 software is implemented as two subsystems:
•
The "env" subsystem monitors for failure events, displays console messages, and invokes functions to send SNMP traps.
•
The "envmib" adds SNMP support for maintaining MIB tables and routines to send traps.
Benefits
This feature provides higher reliability, power-load balancing, and SNMP status messages.
Despite any changes in environmental status, the Cisco IOS software will always attempt to continue running normally and passing packets, while at the same time providing as much information as possible through the user interfaces.
Restrictions
This feature works in conjunction with an optional hardware module. Make sure your access server has the module installed.
Cisco AS5300 software maintains only the current status of the redundant power supply unit. It does not keep track of the history of Redundant Power Supply (RPS) unit failure events.
CISCO-ENVMON-MIB and CISCO-ACCESS-ENVMON-MIB are generally supported, however, the complete status MIB tables defined in CISCO-ENVMON-MIB are not supported due to a limitation in the power supply units. For example, the power supply units do not send current/threshold values, such as current voltage and current temperature, to the motherboard for failure events.
Platforms
This document describes the dual redundant power supply feature as supported by the Cisco AS5300.
This feature is also supported on these platforms:
•
Cisco 3600 routers (3620 and 3640)
•
Cisco 7200 series
•
Cisco 12000 series
The information provided by the show environment command in this feature is a subset of the command already implemented on the Cisco 7200 series and the Cisco 12000 series. The software support for the Cisco 3620 and the Cisco 3640 routers that have a RPS installed is similar but is limited by the router series registers. Although the Cisco 3600 series routers RPS can be installed in other Access platforms, such as the Cisco 4000 series and the Cisco 2500 series, the latter platforms do not provide all the features described in this document.
Prerequisites
The following Cisco IOS releases fully support the redundant power supply:
•
11.3(6)T and later
•
11.3(6)AA and later
•
12.0(1) and later
If you use a Cisco AS5300 motherboard with an older Cisco IOS version, you can use the redundant power supply with older releases for power-load balancing purposes only.
Supported MIBs and RFCs
Whenever Cisco IOS software detects a failure or recovery event from the DRPS unit, it sends an SNMP trap to the configured SNMP server. Unlike console messages, only one SNMP trap is sent when the failure event is first detected. Another trap is sent when the recovery is detected.
Cisco AS5300 DRPS software reuses the MIB attributes and traps defined in CISCO-ENVMON-MIB and CISCO-ACCESS-ENVMON-MIB. CISCO-ENVMON-MIB is supported by all Cisco routers with RPS units, and CISCO-ACCESS-ENVMON-MIB is supported by the Cisco 3600 series routers.
•
A power supply trap defined in CISCO-ENVMON-MIB is sent when a failure is detected and when a failure recovery occurs for the following events: input voltage fail, DC output voltage fail, thermal fail, and multiple failure events.
•
A fan failure trap defined in CISCO-ENVMON-MIB is sent when a fan failure or recovery event is detected by Cisco IOS software.
•
A temperature trap defined in CISCO-ACCESS-ENVMON-MIB is sent when a board overtemperature condition is detected by Cisco IOS software.
•
CISCO-ACCESS-ENVMON-MIB is extended to define an overvoltage trap. A similar trap is defined in CISCO-ENVMON-MIB, but it requires the ciscoEnvMonVoltageStatusValue in varbinds. This value indicates the current value of the voltage in the redundant power supply. With Cisco AS5300 redundant power supply units, the current voltage value is not sent to the motherboard. The CISCO-ACCESS-ENVMON-MIB is extended to support overvoltage trap with new varbinds.
•
CISCO-ENVMON-MIB is extended to add a new enumerated value, internalRedundant(5), for MIB attribute ciscoEnvMonSupplySource. This is used to identify a Cisco AS5300 redundant power supply unit.
For descriptions of supported MIBs and how to use MIBs, see Cisco's MIB Web site on CCO at http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml.
Functional Description
The dual redundant power supply operates automatically. There are three ways to check the status of the power supply unit:
•
Watch the console for messages
•
Use the show environment command
•
Configure SNMP to send trap messages to an SNMP management console
Messages are displayed on the console for each failure event when it is detected and are repeated each minute until the problem is corrected. When the Cisco AS5300 detects a recovered failure, another message is displayed on the console indicating the recovery. shows the RPS failure events and the console messages they produce.
Table 1
Dual Redundant Power Supply Messages
Note
One of the events tracked in the ENVMON MIB is the Cisco AS5300 motherboard overtemperature. Motherboard overtemperature was monitored in earlier Cisco IOS releases. This release enables the Cisco AS5300 to send SNMP traps for this event.
The quickest way to display a summary report of the RPS status is to enter the show environment command at the console. This command is described in "show environment" on page 7.
To report RPS events to an SNMP management console, you need to configure SNMP as described in the next section. When SNMP is configured and the Cisco IOS software detects a failure or recovery from the redundant power supply unit, it sends an SNMP message to the configured SNMP server. Unlike messages that are sent to the console every minute, only one SNMP message is sent when the failure is first detected; and another one is sent when the recovery is detected.
Configuration Tasks
This section describes how to configure the Cisco AS5300 to send SNMP traps to an SNMP management console. It includes the following tasks:
•
Configuring SNMP
•
Verifying the SNMP configuration
•
Troubleshooting tips
Use this section to manage your Cisco AS5300 universal access server to use SNMP traps (messages). If you do not want to implement SNMP traps, skip this section.
Configure
The following table shows how to use the redundant power supply feature commands to configure the feature.
Verify
To verify you have enabled sending SNMP traps for redundant power supply events:
•
Enter the show running-config command and note that envmon is enabled:
5300# show running-configBuilding configuration...Current configuration:!version 12.0service timestamps debug uptimeservice timestamps log uptimeno service password-encryption!hostname as5300!ip subnet-zero!!interface Ethernet0ip address 1.16.44.23 255.255.255.0no ip directed-broadcast!interface FastEthernet0no ip addressno ip directed-broadcastshutdown!ip classlessip route 0.0.0.0 0.0.0.0 Ethernet0ip route 223.255.254.0 255.255.255.0 Ethernet0!snmp-server community public ROsnmp-server enable traps snmpsnmp-server enable traps isdn call-informationsnmp-server enable traps configsnmp-server enable traps entitysnmp-server enable traps envmonsnmp-server enable traps bgpsnmp-server enable traps frame-relaysnmp-server enable traps syslogsnmp-server host 172.22.19.7 traps public!line con 0transport input noneline aux 0line vty 0 4login!endTips
If you are having trouble:
•
Verify that you installed the redundant power supply unit properly.
•
Verify that you entered the snmp-server commands (mentioned in the "Configure" section) properly.
Command Reference
This section documents new or modified commands. All other commands used with this feature are documented in the Cisco IOS Release 11.3 and 12.0 command references.
This section describes the following commands:
show environment
To display the SNMP environment statistics for the Cisco AS5300 Dual Redundant Internal Power Supply, use the show environment privileged EXEC command.
show environment
Syntax Description
When used on the Cisco AS5300, this command has no keywords or arguments.
Default
This command always displays the redundant internal power supply statistics in the same format.
Command Mode
Privileged EXEC
Usage Guidelines
This command first appeared in Cisco IOS Release 10.0. It has been modified for the Cisco AS5300 for Cisco IOS Release 11.3(6)AA.
The information is displayed on the console only; it is not logged to a file.
For information on how this command is used with Cisco IOS 12.0 software on the Cisco 7000 series, Cisco 7200 series, Cisco 7500 series, and Cisco 12000 series Gigabit Switch Router, go to Cisco Connection Online (CCO) at http://www.cisco.com, or the Cisco Documentation CD-ROM.
The CCO path is:
Cisco Connection Online: Products and Ordering: Cisco Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.0: Configuration Guides and Command References: Configuration Fundamentals Command Reference: System Management Commands: Troubleshooting Commands
To access platform documents on the Documentation CD-ROM, follow this path:
Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.0: Configuration Guides and Command References: Configuration Fundamentals Command Reference: System Management Commands: Troubleshooting Commands
For information on how this command is used with Cisco IOS 11.3 software on the Cisco 7000 series, Cisco 7200 series, Cisco 7500 series, and Cisco 12000 series Gigabit Switch Router, go to Cisco Connection Online (CCO) at http://www.cisco.com, or the Cisco Documentation CD-ROM.
The CCO path is:
Cisco Connection Online: Products and Ordering: Cisco Documentation: Cisco IOS Software Configuration: Cisco IOS Release 11.3: Cisco IOS 11.3 Configuration Guides, Command References: System Management: Troubleshooting Commands
To access platform documents on the Documentation CD-ROM, follow this path:
Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 11.3: Cisco IOS 11.3 Configuration Guides, Command References: System Management: Troubleshooting Commands
Example
The following is sample output from the show environment command:
AS5300# show environmentPower Supply:Redundant Power System is present.RPS Input Voltage status: normalRPS Output Voltage status: normalRPS Fan status: normalRPS Thermal status: normalRPS OverVoltage status: normalBoard Temperature: normal.AS5300#
Note
All the above status reports will show either normal or failure. Thermal status refers to the power supply. Board Temperature refers to the motherboard. If more than one parameter displays failure, a separate multiple failure message is reported. For more information, see the "Functional Description" section.
Related Commands
show environment
snmp-server host
snmp-server enable trapssnmp-server enable traps
To enable the router to send SNMP traps and informs, use the snmp-server enable traps global configuration command. Use the no form of this command to disable SNMP notifications.
snmp-server enable traps [notification-type] [notification-option]
no snmp-server enable traps [notification-type] [notification-option]
Syntax Description
Defaults
This command is disabled by default. Most notification types are disabled. However, some notification types cannot be controlled with this command. For example, some notification types are always enabled. Other notification types are enabled by a different command. For example, the linkUpDown notifications are controlled by the snmp trap link-status command.
If you enter this command with no notification-type keywords, the default is to enable all notification types controlled by this command.
Command Mode
Global configuration
Usage Guidelines
This command first appeared in Cisco IOS Release 11.1.
This command is useful for disabling notifications that are generating a large amount of uninteresting or useless noise.
SNMP notifications can be sent as traps or inform requests. This command enables both traps and inform requests for the specified notification types.
If you do not enter an snmp-server enable traps command, no notifications controlled by this command are sent. In order to configure the router to send these SNMP notifications, you must enter at least one snmp-server enable traps command. If you enter the command with no keywords, all notification types are enabled. If you enter the command with a keyword, only the notification type related to that keyword is enabled. In order to enable multiple types of notifications, you must issue a separate snmp-server enable traps command for each notification type and notification option.
The snmp-server enable traps command is used in conjunction with the snmp-server host command. Use the snmp-server host command to specify which host or hosts receive SNMP notifications. In order to send notifications, you must configure at least one snmp-server host command.
For a host to receive a notification controlled by this command, both the snmp-server enable traps command and the snmp-server host command for that host must be enabled. If the notification type is not controlled by this command, just the appropriate snmp-server host command must be enabled.
The notification types used in this command all have an associated MIB object that allows them to be globally enabled or disabled. Not all of the notification types available in the snmp-server host command have notificationEnable MIB objects, so some of these cannot be controlled using the snmp-server enable command.
Examples
The following example enables the router to send all traps to the host myhost.cisco.com using the community string public:
snmp-server enable trapssnmp-server host myhost.cisco.com publicThe following example enables the router to send Frame Relay and environmental monitor traps to the host myhost.cisco.com using the community string public:
snmp-server enable traps frame-relaysnmp-server enable traps envmon temperaturesnmp-server host myhost.cisco.com publicThe following example will not send traps to any host. The BGP traps are enabled for all hosts, but the only traps enabled to be sent to a host are ISDN traps.
snmp-server enable traps bgpsnmp-server host bob public isdnThe following example enables the router to send all inform requests to the host myhost.cisco.com using the community string public:
snmp-server enable trapssnmp-server host myhost.cisco.com informs version 2c publicRelated Commands
show environment
snmp-server host
snmp-server informs
snmp-server trap-source
snmp trap illegal-address
snmp-server host
Use the snmp-server host command in global configuration mode to specify the SNMP server host to which you want to send traps. Use to no form of the command to remove the specified host.
snmp-server host ip-address [traps | informs] [version {1 | 2c}] community-string [udp-port port]
[notification-type]
no snmp-server host ip-address [traps | informs]
Syntax Description
Defaults
This command is disabled by default. No notifications are sent.
If you enter this command with no keywords, the default is to send all trap types to the host. No informs will be sent to this host.
If no version keyword is present, the default is version 1. If no traps or informs keyword is present, traps are enabled.
The no snmp-server host command with no keywords will disable traps, but not informs, to the host. In order to disable informs, use the no snmp-server host informs command.
Command Mode
Global configuration mode
Usage Guidelines
This command first appears in Cisco IOS Release 10.0.
SNMP notifications can be sent as traps or inform requests. Traps are unreliable because the receiver does not send acknowledgments when it receives traps. The sender cannot determine if the traps were received. However, an SNMP entity that receives an inform request acknowledges the message with an SNMP response PDU. If the sender never receives the response, the inform request can be sent again. Thus, informs are more likely to reach their intended destination.
However, informs consume more resources in the agent and in the network. Unlike a trap, which is discarded as soon as it is sent, an inform request must be held in memory until a response is received or the request times out. Also, traps are sent only once, while an inform may be retried several times. The retries increase traffic and contribute to a higher overhead on the network.
If you do not enter an snmp-server host command, no notifications are sent. In order to configure the router to send SNMP notifications, you must enter at least one snmp-server host command. If you enter the command with no keywords, all trap types are enabled for the host. In order to enable multiple hosts, you must issue a separate snmp-server host command for each host. You can specify multiple notification types in the command for each host.
When multiple snmp-server host commands are given for the same host and kind of notification (trap or inform), each succeeding command overwrites the previous command. Only the last snmp-server host command will be in effect. For example, if you enter an snmp-server host inform command for a host and then enter another snmp-server host inform command for the same host, the second command will replace the first.
The snmp-server host command is used in conjunction with the snmp-server enable command. Use the snmp-server enable command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable command and the snmp-server host command for that host must be enabled.
However, some notification types cannot be controlled with the snmp-server enable command. For example, some notification types are always enabled. Other notification types are enabled by a different command. For example, the linkUpDown notifications are controlled by the snmp trap link-status command. These notification types do not require an snmp-server enable command.
A notification-type option's availability depends on the router type and Cisco IOS software features supported on the router. For example, the envmon notification-type is available only if the environmental monitor is part of the system.
Examples
The following example sends the SNMP traps defined in RFC 1157 to the host specified by the name myhost.cisco.com. The community string is defined as comaccess.
snmp-server enable trapssnmp-server host myhost.cisco.com comaccess snmpThe following example sends the SNMP and Cisco environmental monitor enterprise-specific traps to address 172.30.2.160:
snmp-server enable trapssnmp-server host 172.30.2.160 public snmp envmonThe following example enables the router to send all traps to the host myhost.cisco.com using the community string public:
snmp-server enable trapssnmp-server host myhost.cisco.com publicThe following example will not send traps to any host. The BGP traps are enabled for all hosts, but only the ISDN traps are enabled to be sent to a host.
snmp-server enable traps bgpsnmp-server host bob public isdnThe following example enables the router to send all inform requests to the host myhost.cisco.com using the community string public:
snmp-server enable trapssnmp-server host myhost.cisco.com informs version 2c publicRelated Commands
show environment
snmp-server enable traps
snmp-server informs
snmp-server trap-source
snmp-server trap-timeout
snmp trap link-status
What to Do Next
For more information on the Cisco AS5300, go to Cisco Connection Online (CCO) at http://www.cisco.com, or the Cisco Documentation CD-ROM.
The CCO path is:
Cisco Connection Online: Products and Ordering: Cisco Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5300
To access platform documents on the Documentation CD-ROM, follow this path:
Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5300