Table Of Contents
S4T68360 Error Messages
SCHED Error Messages
SDLC Error Messages
SDLLC Error Messages
SEC Error Messages
SERVICE MODULE Error Messages
SLIP Error Messages
SMF Error Message
SMRP Error Messages
SNAPSHOT Error Messages
SNMP Error Messages
SSE Error Messages
STANDBY Error Messages
STUN Error Messages
SUBSYS Error Messages
SYS Error Messages
SYSMGT Error Messages
TAC Error Messages
TBRIDGE Error Messages
TCP Error Messages
TMQ Error Message
TN Error Messages
TN3270 Error Message
TR Error Messages
TUN Error Messages
UCODE Error Messages
UNIX Error Message
UTIL Error Messages
VINES Error Messages
VIP Error Messages
X25 Error Messages
XNS Error Messages
S4T68360 Error Messages
S4T68360 error messages relate to the 4-port synchronous serial adapter based on the 68360 processor.
Error Message
%S4T68360-1-DISCOVER: only found [dec] interfaces on bay [dec],
shutting down bay
Explanation A port adaptor hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-1-DWNLDFL: s4t_msg_download_fail
Explanation The S4T hardware has failed. It could not download its operational
microcode.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-1-DWNLDCKSM: s4t_msg_cksm_fail
Explanation The download of the internal firmware to the S4T failed to checksum
correctly. This usually indicates a hardware failure of the S4T or the Versatile Interface
Processor (VIP).
Recommended Action Perform a power cycle. If the problem persists, the S4T hardware
may have a problem.
Error Message
%S4T68360-1-INITFAIL: s4t_msg_initfail
Explanation The S4T port adaptor failed to complete hardware initialization.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-3-MBXREAD: s4t_msg_mbxread
Explanation The S4T has not responded to a message from the Versatile Interface
Processor (VIP) within a specified time.
Recommended Action Perform a microcode reload of the VIP. If the problem persists, it
indicates that the S4T or VIP hardware failed.
Error Message
%S4T68360-1-NOTCMPLT: s4t_msg_download_ncmplt
Explanation The S4T port adaptor hardware failed. It did not acknowledge the
completion of the operational microcode download.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-1-NOTREADY: s4t_msg_notready
Explanation The S4T port adaptor hardware failed. The S4T port adaptor would not begin
to download the operational microcode.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-3-NOTS4T68360: At [hex], device reported [hex]
Explanation The S4T hardware failed. A non-S4T device pointed at the software for the
S4T.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-3-OWNERR: msgtxt_ownerror
Explanation A software or hardware error occurred. The S4T driver detected that the
transmit ring is an inconsistent and unrecoverable state.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-3-PANIC: s4t_msg_panic
Explanation The S4T firmware detected an illegal or unexpected CPU exception or
condition. This may be caused by a software error or by a hardware failure.
Recommended Action Perform a microcode reload of the Versatile Interface Processor
(VIP). If the problem persists, it indicates that the S4T hardware failed.
Error Message
%S4T68360-1-STARTFAIL: s4t_msg_startfail
Explanation A software or hardware error occurred. The S4T interface is not responding
to commands used to initialize it.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-1-STOPFAIL: s4t_msg_stopfail);
Explanation The S4T port adaptor failed to respond to a request to disable an interface.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%S4T68360-3-TOOSMALL: s4t_msg_toosmall
Explanation An output packet was detected that was smaller than the minimum allowable
datagram size. An error in another driver or an error in the system software probably
triggered this error message.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
SCHED Error Messages
Scheduler error messages
Error Message
%SCHED-2-ATTRCMD: Attempt to [chars] attribute [chars] on process
[dec]., 30*ONESEC
%SCHED-2-ATTRVALUE: Attempt to set bad [chars] value ([hex]) on
process [dec].
%SCHED-2-EDISMSCRIT: Critical priority process [chars] may not
dismiss., 30*ONESEC
%SCHED-3-LOSTWAKEUP: Wakeup information for process [chars] lost
(maj [hex], min [hex])., 30*ONESEC
%SCHED-2-NOATTR: Attempt to [chars] unknown process attribute
[dec]., 30*ONESEC
%SCHED-2-NOTWATCHTIMER: [chars] timer [hex] not being watched.,
30*ONESEC
%SCHED-3-PAGEZERO: Low memory modified by [chars] ([hex] = [hex]).
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-PRIORITY: Illegal priority ([dec]) specified for process
[chars]., 30*ONESEC
%SCHED-2-QUEUENOTEMPTY: Attempt to delete non-empty watched queue
[chars] (address [hex])., 30*ONESEC
%SCHED-2-SEMUNLOCK: [chars] attempted to unlock semaphore owned by
[chars], 30*ONESEC
%SCHED-3-STACKSIZE: Illegal stack size ([dec]) specified for process
[chars]., 30*ONESEC
%SCHED-3-STUCKMTMR: Sleep w/expired mgd timer [hex], time %#Ta (%TE
ago)., ONEMIN
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-STILLWATCHING: Process still watching [chars] [chars].
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-STILLWATCHINGT: Process still watching [chars] timer [hex].
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-STUCKTMR: Sleep w/expired timer [hex], time %#Ta (%TE
ago)., ONEMIN
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-THRASHING: Process thrashing on watched [chars]., ONEMIN
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SCHED-3-UNEXPECTEDEVENT: Process received unknown event (maj [hex],
min [hex])., 30*ONESEC
%SCHED-3-UNEXPECTEDMESSAGE: Unknown message [hex] received (ptr arg
[hex], num arg [hex])., 30*ONESEC
%SCHED-3-UNEXPECTEDQUEUE: Queue event for unknown queue (index
[dec])., 30*ONESEC
%SCHED-3-UNEXPECTEDTIMER: Unknown timer expiration, timer = [hex],
type [dec], 10 * ONESEC
%SCHED-2-WATCH: Attempt to [chars] uninitialized watched [chars]
(address [hex])., 30*ONESEC
%SCHED-2-WATCHTIMER: Request to watch [chars] timer [hex] ([chars]
timer [hex] active)., 30*ONESEC
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
SDLC Error Messages
Synchronous Data Link Control error messages
Error Message
%SDLC-6-BADFRAME: [chars], Received bad SDLC [chars]frame, address
[hex], control [hex] , 30*ONESEC
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-5-CONFIGERR: [chars], addr [hex], Sent SNRM, received SNRM.
Check link station roles., 20*ONESEC
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-4-CTRLBAD: Interface [chars], Invalid control field
Explanation A bad SDLC frame was received.
Recommended Action If this message recurs, check the SDLC serial line and the devices
attached to it.
Error Message
%SDLC-3-DLU_ERROR: [chars], DLU failed to close station [hex] before
re-opening, [chars]/[chars], ONESEC
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-4-DROPPED: Dropped SDLC packet from SDLC hold queue, 10
Explanation An SDLC frame had to be dropped from the output hold queue, usually
because of excessive congestion on the output link.
Recommended Action If this message occurs frequently, determine why your SDLC link
is being overloaded with data and resolve the cause (typically by either increasing
bandwidth to your SDLC line or reducing the load on your link).
Error Message
%SDLC-4-FRAMEERR: Interface [chars], Frame error:
CF [hex], VS [dec] [char] VR [dec], Reason [hex]
Explanation A FRMR frame was received. This can be due to a noisy serial line, an
overloaded SDLC device, or corrupted data.
Recommended Action If this message recurs, service the serial line and the devices
attached to it.
Error Message
%SDLC-2-ILLEGSTATE: Illegal state, [hex] [dec]
Explanation An internal SDLC state violation was detected.
Recommended Action Record the entire error message and call your technical support
representative for assistance.
Error Message
%SDLC-4-INFOBAD: Interface [chars], Info field not permitted
%SDLC-4-INVNR: Interface [chars], Invalid NR value
Explanation A bad SDLC frame was received.
Recommended Action If any of these messages recur, check the SDLC serial line and the
devices attached to it.
Error Message
%SDLC-5-INVLDGRPCFG: Interface [chars], ignoring group-poll
mismatch, UPOLL [hex], 60*ONEMIN
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-4-INVLDGRPPOLL: Interface [chars], Invalid group-poll frame,
10
Explanation An unnumbered poll (UP) was received with the wrong group poll address.
Recommended Action Make sure the group poll address configured on the router
matches the one configured in the physical unit (PU) macro (GP3174=XX) in the Network
Control Program (NCP) generate file.
Error Message
%SDLC-5-INVLDGRPPOLL: Interface [chars], not configured for
group-poll frame, received [hex], 60*ONEMIN
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-2-NOBUF: Interface [chars], no buffer available to [chars]
Explanation Insufficient memory available.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SDLC-4-NOFRMRSPACE: Cannot allocate a FRMR frame
Explanation The router needed to generate an FRMR frame but could not allocate the
necessary memory for the frame.
Recommended Action The fact that memory is so low that it cannot allocate the frame is
far more serious than the reason for generating the FRMR. Fix the cause of low memory,
and if the problem still occurs, determine why the FRMR must be sent.
Error Message
%SDLC-3-NOINPIDB: Input idb not set
Explanation This is a software error. A frame was given to the SDLC handler to process,
but the interface on which the frame arrived is not known.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-2-NOPOINTER: AW_SDLC_SEC with no sdllc_llc pointer
Explanation An error condition occurred during SDLLC initiation.
Recommended Action No action is required. The SDLLC session will restart without
operator intervention.
Error Message
%SDLC-4-NOUA: Interface [chars], address [hex] non UA frame is
received in response to SNRM, 99999
Explanation The router received a frame other than a UA in response to a SNRM.
Recommended Action Check the end station to see if the SNA stack is up and running.
Error Message
%SDLC-3-NULLPAK: Interface [chars], NULL packet ptr, rvr [dec], vs
[dec], vr [dec]
Explanation An internal software error occurred in the router's SDLC processing system.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-4-SDLC_ERR: SDLC_ERROR with no poll
Explanation A protocol error was detected on a secondary station, but FRMR could not
be sent because the station did not own the poll bit. This message indicates either poor line
conditions or a faulty SDLC implementation.
Recommended Action If the message recurs, run traces on the SDLC line. Copy the error
message exactly as it appears, and report it to your technical support representative.
Error Message
%SDLC-4-UNKNOWNADDR: Received input for unknown addr/input addr
[hex]. Tossing frame.
Explanation SDLC frames were received from an unknown (unconfigured)
SDLC address.
Recommended Action Either configure the station for SDLLC or STUN, or shut down
the serial interface to disable the line. Copy the error message exactly as it appears, and
report it to your technical support representative.
Error Message
%SDLC-4-WRONGADDR: [interface], data from wrong address, expected
[addr], received [addr]
Explanation This condition typically occurs on multidropped lines when the T1 timer
interval is too short or the sdlc line-speed command is not configured. In rare cases the
RTS/CTS handshake can delay the transmission of a frame so long that a response is
returned after the next station is polled.
Recommended Action Adjust the value of the sdlc line-speed statement in the
configuration file. (Either take line traces to observe appropriate T1 timer intervals, or
adjust empirically.)
Error Message
%SDLC-6-XID_DISPLAY: sa [sci_notation] da [sci_notation] ss [hex]
ds [hex] [[hex][hex][hex][hex]], 10
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-6-XID_FORMAT: Unsupported XID format received, format [dec],
10
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SDLC-4-XID_NOMATCH: [chars], XID mismatch for [hex]. CONNECTION
REJECTED, 10
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
SDLLC Error Messages
Synchronous Data Link Control/Logical Link Control, type 2 translation error messages
Error Message
%SDLLC-5-ACT_LINK: SDLLC: [chars] LINK address [hex] ACTIVATED:
[chars]
Explanation An SDLLC media conversion session was activated.
Recommended Action No action is required.
Error Message
%SDLLC-5-DACT_LINK: SDLLC: [chars] LINK address [hex] DEACTIVATED:
[chars]
Explanation An SDLLC media conversion session was deactivated. If deactivation is a
result of an error condition, this message will include a reason.
Recommended Action If the message does not include a description of an error, the
deactivation was normal and the message is for information only. If the message does
include a description of an error, begin problem analysis. Determine whether session loss
is related to LLC2 timers by issuing the debug llc2-err command. If the problem is related
to LLC2 timers, consider using SDLLC with the local acknowledgment feature. Copy the
error message exactly as it appears, and report it to your technical support representative.
Error Message
%SDLLC-6-XID_DISPLAY: sa [enet] da [enet] ss [hex] ds [hex]
[[hex][hex][hex][hex]]
Explanation This message supplies the information for the received and rejected XID.
Recommended Action See also the "SDLLC-6-XID_NOMATCH" error message.
Error Message
%SDLLC-6-XID_FORMAT: Unsupported XID format received, format [dec]
Explanation An inappropriate exchange identification (XID) format was received for this
mode of SDLLC operation. Review the type of devices you are connecting with SDLLC to
make sure they are supported.
Recommended Action See the "SDLLC-6-XID_NOMATCH" error message.
Error Message
%SDLLC-4-XID_NOMATCH: [chars], XID mismatch for [hex]. CONNECTION
REJECTED
Explanation An inbound exchange identification (XID) from a PU 2.0/PU 2.1 node was
rejected. The targeted SDLC address is displayed. The XID information is displayed in a
subsequent message—"SDLLC-6-XID_DISPLAY" or "SDLLC-6-FORMAT."
Recommended Action This is a security feature. Additional information is displayed to
help trace the source of the rejected XID. If the message is undesirable, simply remove the
XID statement from the router configuration.
SEC Error Messages
IP security error messages
Error Message
%SEC-6-IPACCESSLOGDP: list [dec] [chars] [chars] [inet] -> [inet]
([dec]/ [dec]), [dec] packet[chars]
Explanation A packet matching the log criteria for the given access list was detected.
Recommended Action Informational message only. No action required.
Error Message
%SEC-6-IPACCESSLOGNP: list [dec] [chars] [dec] [inet] -> [inet],
[dec] packet[chars]
Explanation A packet matching the log criteria for the given access list was detected.
Recommended Action Informational message only. No action required.
Error Message
%SEC-6-IPACCESSLOGP: list [dec] [chars] [chars] [inet]([dec]) ->
[inet]([dec]), [dec] packet[chars]
Explanation A packet matching the log criteria for the given access list was detected.
Recommended Action Informational message only. No action required.
Error Message
%SEC-3-NOMAX: No default for NLESO defined
%SEC-2-NOOPT: Box secured, no option on internal packet
%SEC-2-NOTSEC: First opt in tcb not BASIC security
%SEC-2-SECINS: Security opt in tcb not SECINSERT
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SEC-4-TOOMANY: Box secured, too many options on internal packet
Explanation No room for all desired IP header options. Packet discarded.
Recommended Action Configure for fewer IP header options.
SERVICE MODULE Error Messages
This section contains error messages generated by the service module.
Error Message
%SERVICE_MODULE-4-ACCESSERROR: Unit [dec] reports register access
error - [chars]
Explanation The T1 module supplied an incorrect register address. A new version of the
module might be operating with an old Cisco IOS software image.
Recommended Action Update the Cisco IOS software image on the system. If this action
does not solve the problem, copy the error message exactly as it appears and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-ALARMFAILURE: Unit [dec] - Could not access alarm
status - disabling alarm processing
Explanation The system issued an alarm interrupt, but could not read the alarm status
register from the module. As a result, the system disabled alarm processing.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-BADTYPE: Unit [dec] - reports incompatible module
type [dec] against router hw detect
Explanation A "register read" request returned an identity for a module that was not the
same as the identity reported by the router hardware pinout.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-COMMANDFAILED: Unit [dec] not ready/responding
after register [dec] access command issued
Explanation The system did not receive a ready signal within the allotted time after
writing to the command register.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-0-INITFAILURE: Unit [dec] - failed to create data
structures used for module-access
Explanation The channel service unit/data service unit (CSU/DSU) driver failed to
allocate memory for its data structures. This is a catastrophic error. The system has crashed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-INTERBYTETIMEOUT: Unit [dec] - timed out while
[chars] byte [dec] of [dec] length register [dec]
Explanation The module took more than 2 seconds to respond between bytes.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-3-LOOPDOWNFAILED: Unit [dec] - WARNING - Loopdown of
remote unit failed
Explanation A remote channel service unit/data service unit (CSU) is looping pings
and/or test patterns back to the system. This error can be triggered if you disable loopback
tests on the remote CSU after placing the remote CSU into a remote loopback state.
Recommended Action Execute a clear command on the remote CSU.
Error Message
%SERVICE_MODULE-5-LOOPDOWNREMOTE: Unit [dec] - Remote loopback test
cancelled
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative for assistance.
Error Message
%SERVICE_MODULE-5-LOOPUPFAILED: Unit [dec] - Loopup of remote unit
failed
Explanation The loopback test on the remote unit failed. The failure might indicate that
the network connection is broken or that loopback tests are disabled at the other side.
Recommended Action Check that the router is connected to the network. Enable
loopback tests on the remote unit. If the problem persists, copy the error message exactly
as it appears and report it to your technical support representative.
Error Message
%SERVICE_MODULE-5-LOOPUPREMOTE: Unit [dec] - Remote unit placed in
loopback
Explanation You executed a loopback command on the remote unit. The remote unit is
now in loopback state.
Recommended Action No action is required.
Error Message
%SERVICE_MODULE-4-NOTREADY: Unit [dec] not ready for register access
Explanation The module was waiting for a ready status before executing a read/write
request. The system reported a not ready status for 5 seconds, which caused the module to
terminate the read/write request.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-OLDIMAGE: Unit [dec] - router image older than
module version - access errors may be seen
Explanation The Cisco IOS software image does not recognize the programmable ROM
(PROM) software version number on the module. The system displays this message if the
PROM has been upgraded to a new version but the Cisco IOS software image has not been
upgraded.
Recommended Action Upgrade the Cisco IOS software image.
Error Message
%SERVICE_MODULE-4-REPEATEDRESET: Unit [dec] - giving up after [dec]
repeated resets couldn't bring module up again
Explanation The software issued several "clear service-module" requests to the module.
The module did not respond to these requests.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-REQUESTOVERLOAD: Unit [dec] - module request
overload - lock access timeout
Explanation The system employs a Cisco IOS scheduler semaphore object to ensure
mutually exclusive access across software threads to the channel service unit/data service
unit (CSU/DSU). A thread had to wait for more than 5 seconds on this semaphore.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-5-RESET: Reset of Unit [dec] issued
Explanation This message indicates that the module was reset.
Recommended Action No action is required.
Error Message
%SERVICE_MODULE-4-RESETFAILURE: Unit [dec] - failed to create reset
process - non-default module configuration may be lost
Explanation To reset the system, the Cisco IOS software must initiate a separate process.
The Cisco IOS software did not have sufficient memory to create this separate process. The
module came up in an initialized state with the default configuration. The user-defined
configuration might have been lost.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SERVICE_MODULE-4-UNKNOWNALARM: Unit [dec] reports unknown network
alarms - alarm status reg = [hex]
Explanation A recent version of the module operating with an old Cisco IOS software
image did not recognize an alarm condition.
Recommended Action Update the Cisco IOS software image on the system. If this action
does not solve the problem, copy the error message exactly as it appears and report it to your
technical support representative.
SLIP Error Messages
Serial Line Internet Protocol error messages
Error Message
%SLIP-2-BADQUOTE: Impossible quoted character [hex]
%SLIP-2-BADSTATE: Impossible input state [hex]
Explanation An internal software error occurred.
Recommended Action If either of these messages recurs, call your technical support
representative for assistance.
SMF Error Message
Software MAC filter error message
Error Message
%SMF-3-NO_MEM: failed to create SMF entry for [sci_notation] on
[chars] from chunk [chars]
Explanation The preallocated memory resources for the SMF have been exhausted.
Recommended Action Reduce the number of interfaces on which transparent bridging is
configured. Copy the error message exactly as it appears, and report it to your technical
support representative.
SMRP Error Messages
Simple Multicast Routing Protocol error messages
Error Message
%SMRP-2-ASSERTFAILED: SMRP assertion failed: [chars]
Explanation The software detected an inconsistency. This is considered a serious error.
The router attempts to continue, but SMRP processing may be impaired.
Recommended Action Copy the error message exactly as it appears, noting any SMRP
problems that you are experiencing, and report it to your technical support representative.
Error Message
%SMRP-7-DEBUGMSG: SMRP Debug: [chars]
Recommended Action This message is generated by some debug commands to provide
additional information about conditions in SMRP.
Recommended Action If you are experiencing problems in SMRP, these messages
should be provided, along with any other information, in a report to your technical support
representative.
Error Message
%SMRP-5-NEIGHBORDOWN: [chars]: SMRP neighbor down - [chars]
Explanation A neighboring SMRP router is now down.
Recommended Action Notification message only. No action required.
Error Message
%SMRP-6-NEIGHBORUP: [chars]: SMRP neighbor up - [chars]
Explanation A neighboring SMRP router has appeared.
Recommended Action Notification message only. No action required.
Error Message
%SMRP-3-NOFDDICOMPAT: SMRP port [chars] disabled; pre-fdditalk not
supported
Explanation SMRP cannot be started on an interface that is running pre-FDDITalk.
Recommended Action Use FDDITalk on the FDDI ring if possible.
Error Message
%SMRP-5-PORTDOWN: [chars]: SMRP port down - [chars]
Explanation An SMRP port is down and is no longer operational.
Recommended Action Notification message only. No action required.
Error Message
%SMRP-6-PORTUP: [chars]: SMRP port up - [chars]
Explanation An SMRP port has come up.
Recommended Action Notification message only. No action required.
SNAPSHOT Error Messages
Snapshot dial-on-demand routing error messages
Error Message
%SNAPSHOT-2-BADSTATE: Bad state for Snapshot block [chars][[dec]],
location [dec]
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SNAPSHOT-2-NOMEMORY: Unable to create Snapshot SAB. Updates will
NOT be sent
Explanation The router is running out of memory, which impacts the operation of
snapshot.
Recommended Action Check memory usage of the router. Copy the error message
exactly as it appears, and report it to your technical support representative.
Error Message
%SNAPSHOT-2-TOOMANYDIALERS: Exceeded maximum dialer interfaces to
watch. Ignoring [chars]
Explanation Snapshot is being used over more than 100 DDR interfaces.
Recommended Action Do not use snapshot over more than 100 DDR interfaces.
SNMP Error Messages
Simple Network Management Protocol error messages
Error Message
%SNMP-3-BADOID: Attempt to generate an invalid object identifier
Explanation A valid object identifier must contain at least two subidentifiers. An attempt
was made to generate an object identifier whose size was less than two.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SNMP-3-BADVALUE: Maximum number of index supported is 8
Explanation An SNMP trap contains some number of MIB objects, and the size of the
instance identifier for these objects is restricted. This message indicates that an attempt was
made to generate an SNMP trap containing a MIB object whose size exceeded this limit.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SNMP-4-NOTRAPIP: SNMP trap source [chars] has no ip address
Explanation The user entered an snmp-server trap-source command. The interface
requested for use as the source address has no address associated with it. The SNMP trap
is being sent anyway, but without the source address that the user intended.
Recommended Action There are two possible solutions. Either enter a no snmp-server
trap-source command to disable the request for a specific source IP address, or add an IP
address to the interface referenced in the snmp-server trap-source configuration
command.
Error Message
%SNMP-3-SOCKET: can't open UDP socket
Explanation The SNMP server was unable to open a port for receiving SNMP requests.
This usually happens when the SNMP server is started using the snmp-server community
configuration command on a router or communication server with an interface that has no
IP address configured. Another possible cause is low memory.
Recommended Action Configure at least one interface with an IP address or specify the
no snmp-server command to remove the SNMP server process. Call your technical
support representative if problems persist or if it becomes necessary to add memory.
Error Message
%SNMP-4-TRAPDROP: [chars]
Explanation An attempt was made to generate an SNMP trap, but the trap could not be
sent because of the reason given in this message. Most likely, this message means that the
SNMP traps process is not running.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative. Use the show process command to determine whether the
SNMP traps process is running. If it is not running, reload the system. If, after reloading,
the SNMP traps process is still not running, there may not be enough memory for it to run.
Error Message
%SNMP-3-TRAPINTR: Attempt to generate SNMP trap from interrupt level
Explanation During the processing of an interrupt, the code attempted to generate an
SNMP trap. This is not allowed.
Explanation Copy the error message exactly as it appears, and report it to your technical
support representative.
SSE Error Messages
Silicon switching engine error messages
Error Message
%SSE-3-BADMEMORY: SSE memory failure detected
Explanation A memory error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-1-BOGUSEQ: SSE bogus equal branch [hex], [hex], [dec] [hex]
Explanation An internal inconsistency in the data structures used by the SSE occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-2-BOGUSEQ: SSE bogus equal branch [hex], [hex], [dec] [hex]
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-6-COMPERR: SSE compilation failure -- [chars]
Explanation A software failure occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-2-HUNG: SSE hung -- [chars]
Explanation The SSE is hung.
Recommended Action Reboot the SSE.
Error Message
%SSE-2-HWFAILURE: SSE hardware failure-- [chars] code [hex]
Explanation A hardware error occurred, indicating an unexpected condition on the silicon
switch processor (SSP) board.
Recommended Action It might be necessary to replace the SSP. Copy the error message
exactly as it appears, and report it to your technical support representative.
Error Message
%SSE-2-MEMERROR: SSE memory failure, address [hex] expected [hex],
got [hex]
Explanation A hardware error occurred, indicating memory failure on the silicon switch
processor (SSP) board.
Recommended Action It might be necessary to replace the SSP. Copy the error message
exactly as it appears, and report it to your technical support representative.
Error Message
%SSE-1-NESTADDR: SSE nested addresses detected, protocol [dec] [dec]
Explanation An internal inconsistency in the data structures used by the SSE occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-2-NESTADDR: SSE nested addresses detected, protocol [dec] [int]
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-1-NOMATCH: SSE delete didn't end at a match node, type [char]
value [dec], address [dec], bytecount [dec], high [dec], state [dec]
Explanation An internal inconsistency in the data structures used by the SSE occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-2-NOMATCH: SSE delete didn't end at a match node, type [char],
value [dec], address [int], bytecount [dec], high [dec]
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SSE-3-NOMEMORY: No memory available for [chars]
Explanation An operation could not be accomplished because of a low memory
condition.
Recommended Action Reduce other system activity to ease memory demands. If
conditions warrant, upgrade to a larger memory configuration.
Error Message
%SSE-2-NOTZERO: Program memory does not start at zero
Explanation A hardware error occurred, indicating an unexpected condition on the silicon
switch processor (SSP) board.
Recommended Action It might be necessary to replace the SSP. Copy the error message
exactly as it appears, and report it to your technical support representative.
Error Message
%SSE-2-SWFAILURE: SSE software failure -- [chars] [hex]
Explanation A software failure occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
STANDBY Error Messages
Hot Standby Router Protocol error messages
Error Message
%STANDBY-3-BADAUTH: Bad authentication from [inet], remote state
[chars]
Explanation Two routers participating in the Hot Standby protocol disagree on the valid
authentication string.
Recommended Action Use the standby authentication interface command to repair the
Hot Standby protocol authentication discrepancy between the local system and the one
whose IP address is reported.
Error Message
%STANDBY-3-MISCONFIG: Attempt to change [chars] MAC address to
[enet] when DECNET already running
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%STANDBY-3-NOBUFFER: No buffer available for sending HELLO
Explanation The Hot Standby protocol software was unable to allocate a packet buffer.
The system may be out of memory.
Recommended Action Record the output from the following commands: show proc
mem (repeated twice), show mem, show buffers, show version, write terminal. Provide
this information to your technical support representative.
Error Message
%STANDBY-3-NOMEMORY: No memory available for [chars]
Explanation The system was unable to initialize the Hot Standby protocol on an interface.
The system may be out of memory.
Recommended Action Record the output from the following commands: show proc
mem (repeated twice), show mem, show version, write terminal. Provide this
information to your technical support representative.
Error Message
%STANDBY-3-NOSOCKET: Unable to open socket
Explanation The system was unable to initialize an IP connection for the Hot Standby
protocol.
Recommended Action Make sure that there is at least one interface configured to run IP.
STUN Error Messages
Serial tunneling error messages
Error Message
%STUN-3-BADCONN: CONN: bad connection ([dec]), peer:
[chars]
%STUN-3-BADLENOP: [chars]: bad len or unknown op,
op [dec], len [dec]
%STUN-3-BADMAGIC: [chars]: wrong magic, mine [hex],
theirs [hex] ([dec])
%STUN-3-BADMAGICTCP: [chars]: peer [chars], wrong
magic, min [hex], theirs [hex]
%STUN-3-BADPASSIVEOPEN: passive open from [inet]
([dec]) -> [dec] failed
%STUN-3-CONNILLSTATE: CONN: Peer [chars], illegal
state [dec]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%STUN-6-CONNOPENFAIL: CONN: peer [chars] open failed,
[chars] [[dec]]
Explanation An attempt to connect to a remote TCP STUN peer failed.
Recommended Action Verify that the remote peer is accessible from this router, that it is
running software capable of supporting STUN, and that it is configured correctly.
Error Message
%STUN-6-ERR: [chars]: [chars]: [chars], op [hex], len [dec]
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%STUN-2-NOBUF: Interface [chars], no buffer available to [chars]
Explanation A memory shortage existed at the time that the configuration command was
issued. This condition is rare and, under normal conditions, temporary.
Recommended Action Reconfigure the STUN group. If memory shortages persist, call
your technical support representative for assistance.
Error Message
%STUN-3-NOINPIDB: Input idb not set, 10
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%STUN-3-NOPROTMEM: No memory for STUN protocol
definition of [chars]
Explanation The system does not have sufficient memory to define a new STUN schema.
Recommended Action This error message should only print when the router is critically
short of memory. Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%STUN-3-NOTGEM: No memory for STUN protocol sdlc-tg definition
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%STUN-2-NOTGI: Please remove and redefine protocol group [dec]
Explanation An internal error occurred. The configuration is irregular.
Recommended Action Remove and reconfigure the STUN protocol group. Record the
configuration and call your technical support representative for assistance.
Error Message
%STUN-6-OPENED: [chars]: peer [chars] opened,
[previous state [chars]]
%STUN-6-OPENING: CONN: opening peer [chars], [dec]
%STUN-6-PASSIVEOPEN: passive open [inet]([dec]) -> [dec]
Explanation A connection attempt to a remote peer completed successfully (OPENED,
PASSIVE-OPEN) or is in the process of being opened (OPENING). This is good, expected
behavior.
Recommended Action Informational message only. No action required.
Error Message
%STUN-6-PEERSHUTDOWN: shutting down peer [chars] on [chars]
Explanation A connection to a remote peer is being shut down. This is typically the result
of user intervention in STUN reconfiguration or disabling. This is good, expected behavior.
Recommended Action Informational message only. No action required.
Error Message
%STUN-4-PEERSTATE: Peer [chars], wrong state [dec] ([dec])
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%STUN-6-RECONNECT: PHDR: reconnect from peer [chars]
Explanation A remote peer reestablished a connection to this router.
Recommended Action Informational message only. No action required.
Error Message
%STUN-3-SENDPUNT: [chars]: sent [chars] to [chars]
%STUN-3-SENDPUNTTCP: [chars]: sent [chars] to ([[dec]])[inet]
Explanation An internal software error occurred.
Recommended Action If either of these messages recurs, call your technical support
representative for assistance.
Error Message
%STUN-6-TCPFINI: peer [chars] closed [previous state [chars]]
Explanation A remote peer closed a STUN connection with this router.
Recommended Action Examine the other router to see why it closed this connection with
this peer. (This can be caused by normal events, such as reconfiguration.)
Error Message
%STUN-6-TCPPEERSHUT: [chars] [chars], [inet]([dec])
Explanation This route closed a STUN connection with a remote peer.
Recommended Action Examine this router to see why it closed this connection with this
peer. (This can be caused by normal events, such as reconfiguration.)
SUBSYS Error Messages
Software subsystem error messages
Error Message
%SUBSYS-2-BADCLASS: Bad subsystem class [dec] - ignoring subsystem
Explanation A software consistency check failed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SUBSYS-2-BADSEQUENCE: Subsystem ([chars]) has cross-class sequence
for ([chars])
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SUBSYS-2-BADVERSION: Bad subsystem version number [dec] - ignoring
subsystem
Explanation A software consistency check failed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SUBSYS-2-MISMATCH: Kernel and subsystem version differ [dec.dec]
Explanation A software consistency check failed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SUBSYS-2-NOTFOUND: Subsystem [chars] needs subsystem [chars] to
start
Explanation A software consistency check failed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SUBSYS-2-RECURSION: Maximum sequence depth exceeded ([dec]) by
([chars])
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
SYS Error Messages
Operating system error messages
Error Message
%SYS-2-ALREADYFREE: Buffer [hex] already in free pool [chars]
%SYS-3-BADBLOCK: Bad block pointer [hex]
%SYS-3-BADDISP: Bad dispose code [hex] in [chars]
%SYS-3-BADFREEMAGIC: Corrupt free block at [hex] (magic [hex])
Explanation A block of memory is corrupt at the indicated location.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-BADBUFFER: Attempt to use [chars] buffer as [chars], ptr=
[hex], pool= [hex]
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-BADFREEPTRS: Bad [chars] pointer [hex] at [hex] ([chars] =
[hex]
Explanation A pointer in the block header at the indicated location is corrupt.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-3-BADLINKTYPE: Unexpected linktype [dec]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-BADLIST: Regular expression access check with bad list [dec]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-BADMAGIC: Corrupt block at [hex] (magic [hex]
Explanation The free memory pool is corrupted.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-BADPARAM: Function [chars]: value [hex] passed in parameter
[chars]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-BADPID: Bad pid [dec] for tty [t-line]
%SYS-2-BADPOOL: Attempt to return buffer with corrupt pool pointer,
ptr= [hex], pool= [hex]
%SYS-2-BADPOOLMAGIC: Attempt to use pool pointer with corrupt
header, pool= [hex]
%SYS-2-BADSHARE: Bad sharecount in [chars], ptr=[hex],count=[hex]
%SYS-2-BADSTACK: Process [chars] has trashed stack, old size [dec]
%SYS-6-BLKINFO: [chars]blk [hex], words [dec], alloc [hex][chars] RZ
offset [dec], dealloc [hex], rfcnt [hex]
%SYS-2-CFORKLEV: cfork at level [dec]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-3-BADPRINT: Process has no associated tty (in [chars]).,
10*ONESEC
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-BADPROCESS: Bad process ID ([dec]) when [chars] process table
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-BADRESID: Clock hardware returned bad residual [dec]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-BLOCKHUNG: Task hung with blocking disabled, value = 0x[hex],
NOBLOCK_LIMIT
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-CFORKLEV: process create of [chars] failed (at level [dec]),
30*ONESEC
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-CFORKMEM: process create of [chars] failed (no memory),
30*ONESEC
Explanation No memory was available to create a process.
Recommended Action If you suspect a memory leak, copy this message exactly as it
appears, and report it to your technical support representative. If a memory leak does not
appear to be the problem, ensure that more memory is available to support the additional
features.
Error Message
%SYS-2-CHUNKBOUNDS: Attempted to exceed freelist chunk bounds chunk
[hex], data [hex],
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-CHUNKFREE: Attempted to free non-chunk memory, chunk [hex],
data [hex], 10 * ONESEC
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-CHUNKPARTIAL: Attempted to destroy partially full chunk,
chunk [hex], 10 * ONESEC
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-CHUNKSIBLINGS: Attempted to destroy chunk with siblings,
chunk [hex], 10 * ONESEC
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-5-CONFIG: Configured from [chars] by [chars]
%SYS-5-CONFIG_I: Configured from [chars] by [inet]
%SYS-5-CONFIG_L: Configured via LNM from [enet]
%SYS-5-CONFIG_M: Configured via MOP from [chars]
by [enet]
Explanation The router's configuration was changed.
Recommended Action Notification messages only. No action required.
Error Message
%SYS-2-CONFIG_DOWNFAIL: Generated configuration not downward
compatible
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-4-CONFIG_NEWER: Configurations from version [dec].[dec] may not
be correctly understood.
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-5-CONFIG_NV: Non-volatile store configured from [chars] by
[chars]
%SYS-5-CONFIG_NV_M: Non-volatile store configured via MOP from
[chars] by [enet]
Explanation The configuration was written successfully through the Maintenance
Operation Protocol (MOP).
Recommended Action No action required.
Error Message
%SYS-3-CONFIG_NV_ERR: Non-volatile store write error - configuration
failed
Explanation The write of the nonvolatile configuration failed.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-3-CPUHOG: Task ran for [dec] msec. Process = [chars], PC = [hex]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-DMPMEM: [hex]: [hex] [hex] [hex] [hex] [hex] [hex]
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-4-DUAL_MESSAGE: SNMP system message request [dec] denied due to
pending job
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-DUPEXPORT: Duplicate export vector [chars] registration
attempt
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-FREEBAD: Attempted to free memory at [hex], not part of buffer
pool
%SYS-2-FREEFREE: Attempted to free unassigned memory
at[hex], alloc [hex] dealloc [hex]
%SYS-2-GETBUF: Bad getbuffer, bytes= [dec]
%SYS-3-HARIKARI: Process [chars] top-level routine exited
%SYS-2-HEADER: Attempt to return buffer with
invalid buffer header, ptr= [hex]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-2-INLIST: Buffer in list, ptr= [hex]
%SYS-2-INLIST1: Buffer in list, ptr= [hex],
caller= [hex]
%SYS-2-INPUTQ: INPUTQ set, but no idb, ptr=[hex]
%SYS-2-INSCHED: [chars] within scheduler
%SYS-2-INTSCHED: [chars] at level [dec]
%SYS-3-INUSEFREE: Block [hex] on free list [dec] in use
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-3-INTPRINT: Illegal printing attempt from interrupt level.,
10*ONESEC
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-4-INVALID_IMAGE: Running invalid image for platform!
Explanation The software image being run is for a different hardware architecture. This
problem can occur on a Cisco 1003, Cisco 1004, or Cisco 1005. The Cisco 1003 and
Cisco 1004 have a different image from the Cisco 1005.
Recommended Action Install the correct software image.
Error Message
%SYS-3-INVMEMINT: Invalid memory action ([chars]) at interrupt level
Explanation This message indicates that a memory allocation or deallocation was
attempted from an interrupt handler.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-LINKED: Bad enqueue of [hex] in queue [hex]
%SYS-2-LINKED: Bad p_dequeue of [hex] in queue [hex]
%SYS-2-LINKED: Bad p_requeue of [hex] in queue [hex]
%SYS-2-LINKED: Bad requeue of [hex] in queue [hex]
%SYS-2-LOWMEM: Low memory debug exception (limit =[dec] free = [dec])
Explanation The router is running short on memory.
Recommended Action It may be necessary to free some memory by exiting a program.
If this error recurs, copy the error message exactly as it appears and contact your technical
support representative for assistance.
Error Message
%SYS-2-MALLOCFAIL: Memory allocation of [dec] bytes failed from
[hex], pool [chars], alignment [dec]
Explanation The requested memory allocation is not available from the specified memory
pool. The current system configuration, network environment, or possibly a software error
might have exhausted or fragmented the router's memory.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-6-MEMDUMP: [hex]: [hex] [hex] [hex] [hex]
Explanation This message is sent in conjunction with the "%SYS-6-BLKINFO"
message. It provides additional data.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-MGDTIMER: [chars][chars], timer = [hex], 10 * ONESEC
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-MGDTIMEREXP: Unknown timer expiration, timer = [hex], type
[dec], 10 * ONESEC
Explanation The process received an expiration notice for a timer that does not belong to
it.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-MSGLOST: [dec] messages lost due to queue overflow
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%SYS-6-MTRACE: [chars]: addr, pc [hex], [hex] [hex], [hex] [hex],
[hex] [hex], [hex [hex], [hex] [hex], [hex] [hex], [hex] [hex], [hex]
Explanation The free memory pool is corrupted.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-NOBLOCK: [chars] with blocking disabled
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-6-NOBRIDGE: Bridging software not present
Explanation Your system is not equipped to be a bridge.
Recommended Action Install the bridging software option.
Error Message
%SYS-1-NOECO: WARNING: This 500-CS cannot run this version of
software. Please contact Customer Service for upgrade information.
tele: 1 (800) 553-NETS 1 (415) 903-7208 email: cs-rep@cisco.com
Hardware burned in address is [enet]
Explanation An Error Change Order (ECO) is needed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-NOMEMFRG: Memory fragmentation check debug exception
(fragment size [dec])
Explanation The system detected an error checking memory fragmentation.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-NOMEMORY: No memory available for [chars] [dec]
Explanation An operation could not be accomplished because of a low memory
condition.
Recommended Action Reduce other system activity to ease memory demands. If
conditions warrant, upgrade to a larger memory configuration.
Error Message
%SYS-3-NOPROC: Process table full
%SYS-2-NOTDEAD: Rekilling process [chars], pid [dec]
%SYS-2-NOTQ: p_unqueue didn't find [hex] in queue [hex]
%SYS-2-NOTQ: unqueue didn't find [hex] in queue [hex]
%SYS-3-NULLIDB: Null idb in [chars]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-2-NOPROCESS: No such process [dec]
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-3-NZREFCNT: Block [hex] on free list [dec] with ref count [dec]
Explanation A block of memory in the free pool is actually in use. The number of
processes using the memory block is indicated.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-5-OUTSETUP: Configuration file [chars] accepted, aborting setup
Explanation A configuration was accepted through the network, so the setup session will
be aborted.
Recommended Action No action required.
Error Message
%SYS-3-OVERRUN: Block overrun at [hex] (redzone [hex])
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-1-OVERTEMP: System detected OVER TEMPERATURE condition.
Please resolve cooling problem immediately!
Explanation The environmental monitor detected a high temperature condition.
Recommended Action Make sure that the room temperature is not too high and that air
flow to the card is not blocked. If this condition persists, the environmental monitor might
shut the system down. Call your technical support representative for assistance, if
necessary.
Error Message
%SYS-2-PAKCLIP: Bad pak_clip, bytes= [dec]
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-6-PROCINFO: Process [chars] just finished executing.
Explanation This message is an auxiliary to the "SYS-3-OVERRUN" and
"SYS-3-BADMAGIC" error messages. It indicates the process or process fragment that
was executing at the time of the error.
Recommended Action Copy this messages exactly as it appears, and report it, along with
the "SYS-3-OVERRUN" and "SYS-3-BADMAGIC" error messages, to your technical
support representative.
Error Message
%SYS-2-QCOUNT: Bad dequeue [hex] count [dec]
%SYS-2-QCOUNT: Bad p_dequeue [hex] count [dec]
%SYS-2-QCOUNT: Bad p_unqueue [hex] count [dec]
%SYS-2-QCOUNT: Bad unqueue [hex] count [dec]
%SYS-2-QINSERT: Unable to add [chars] to queue - no elements
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-3-REGARG: Registry service [chars] has too many arguments
%SYS-3-REGCREA2: Attempt to create registry service [chars] twice
%SYS-3-REGDFLT: Attempt to add default twice to registry service
%SYS-3-REGNONE: Registry [dec] service [dec] doesn't exist - [chars]
%SYS-3-REGTYPE: Registry service [chars] is wrong type, should be
[dec]
Explanation An internal software consistency check failed.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-5-RELOAD: Reload requested
%SYS-5-RESTART: System restarted -- [chars]
Explanation A reload or restart was requested.
Recommended Action Notification messages only. No action required.
Error Message
%SYS-4-RELOAD_ATTEMPT: Attempt via SNMP failed; system-shutdown not
configured
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%SYS-2-RETBUF: Bad retbuffer, ptr= [hex]
%SYS-2-RETBUF1: Bad retbuffer, ptr= [hex],
caller= [hex]
%SYS-2-SELF: s_setblock() on own process
%SYS-2-SELFLINKED: Buffer [hex] linked to itself in free pool [chars]
%SYS-2-SHARED: Attempt to return buffer with sharecount
[dec],ptr= [hex]
%SYS-2-SHARED1: Attempt to return buffer with sharecount [dec], ptr=
[hex], caller= [hex]
%SYS-3-SOCKUNKN: Unknown socket protocol [dec]
%SYS-2-SPEC: Trying to set unknown special character
[dec] to [dec]
%SYS-6-STACKLOW: Stack for [chars] [chars] running low, [dec]/[dec]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%SYS-2-SMASHED: Smashed block at 4085C, next 0, prev 0, size 3E80000
- Process = *Init*, level=5
Explanation An internal software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%SYS-2-SMASHEDINFO: Smashed block last freed 0, allocated by 30000,
name
Explanation A software error corrupted the memory.
Recommended Action Copy the message exactly as it appears and report it your
technical support representative.
Error Message
%SYS-4-SNMP_HOSTCONFIGSET: SNMP hostConfigSet request. Loading
configuration from [int].
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-4-SNMP_NETCONFIGSET: SNMP netConfigSet request. Loading
configuration from [int].
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-4-SNMP_WRITENET: SNMP WriteNet request. Writing current
configuration to [int].
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-2-SNMP0IDX: Attempt to [chars] snmpidb with if_index of 0.
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears and report it your
technical support representative.
Error Message
%SYS-3-SUPNONE: Registry [dec] doesn't exist
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears and report it your
technical support representative.
Error Message
%SYS-2-SUPNOT: Can't create Registry [chars]
Explanation An internal software consistency check failed.
Recommended Action Copy the message exactly as it appears and report it your
technical support representative.
Error Message
%SYS-2-SUPTWICE: Attempt to create Registry [chars] again, 30 *
ONESEC
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-5-TABLEERR: [chars] table [chars] damaged: [chars]
Explanation An internal table entry became corrupted.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%SYS-6-TESTINFO: Scheduler test [hex] (for [chars]) just executed.
Explanation This message is an auxiliary to the "SYS-3-OVERRUN" and
"SYS-3-BADMAGIC" error messages. It indicates which process or process fragment was
executing at the time of the error.
Recommended Action Copy this message exactly as it appears, and report it, along with
the "SYS-3-OVERRUN" and "SYS-3-BADMAGIC" error messages, to your technical
support representative.
Error Message
%SYS-3-TIMERHOG: Timer callback ran long, PC = [hex], 10*ONESEC
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%SYS-3-TIMERNEG: Cannot start timer ([hex]) with negative offset
([dec])., 10 * ONESEC
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYS-3-TTYMEM: Tty[t-line], no memory to save tty default parameters
Explanation The requested operation could not be accomplished because of a low
memory condition.
Recommended Action Reduce other system activity to ease memory demands. If
conditions warrant, upgrade to a larger memory configuration.
Error Message
%SYS-2-WATCHDOG: Process aborted on watchdog timeout, Process =
[chars], ONESEC
Explanation The indicated process ran for such a long time without relinquishing the
processor that the system killed it as a runaway.
Recommended Action If this error recurs, call your technical support representative for
assistance.
Error Message
%SYS-3-WRONGFREELIST: Block [hex], size [dec], on wrong free list
([dec], [dec])
Explanation A freed buffer was placed on the wrong list of free buffers.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%SYS-2-WRONGPOOL: Buffer [hex] found in pool [hex], should be in pool
[hex]
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
SYSMGT Error Messages
System Management error messages
Error Message
%SYSMGT_RPC-3-IPC_ERROR: SYSMGT RPC - IPC [chars] [chars] failed
([chars])
Explanation The Channel Interface Processor (CIP) card network management event
processing subsystem failed to set up the Interprocess Communications port. Network
management events will not be processed from installed CIP cards.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYSMGT_RPC-3-NETMGT_EVENT: SYSMGT RPC - NETMGT Event: [chars]
([dec])
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%SYSMGT_SNALLC-3-EVENT_ERROR: SYSMGT SNA LLC - [chars] ([dec])
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
TAC Error Messages
Terminal Access Controller Access Control System (TACACS) protocol error messages
Error Message
%TAC-6-SENDTMO: Send type [dec] to [inet] timed out
Explanation A background TACACS notification (enabled with the command tacacs
notify) was not acknowledged by the TACACS server processor within the timeout period
(5 minutes). The information contained in that notification was lost. This loss of
information may interfere with accounting or auditing on the server.
This condition arises when the TACACS server is misconfigured, crashed, or became unreachable via the network.
Recommended Action Check the TACACS server and the network attached to it.
Error Message
%TAC-4-UNEXREP: Reply for non-existent request, [dec] on queue
Explanation The TACACS facility received a message it was not expecting. This may
occur when a TACACS server sends duplicate responses or when it responds to a request
that has already timed out. It also may be due to an internal software problem.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
TBRIDGE Error Messages
Transparent bridging error messages
Error Message
%TBRIDGE-4-GIANT: Giant received on [chars], [dec] exceeds [dec]\n
DA [enet] SA [enet] [[hex]], (5 * ONESEC)
Explanation A packet was received that exceeds the expected maximum transmission unit
(MTU) length for the receiving interface. The first four bytes of the packet following the
source address are also provided to assist diagnosis.
Recommended Action Use the address and packet information provided to trace the
source of these packets and reduce its MTU to conform to the standard for the given media.
Error Message
%TBRIDGE-4-INVALIDMEDIA: Invalid media encountered for bridging
Explanation Transparent bridging was configured on an interface that does not support it.
Recommended Action Remove transparent bridging from the configuration on the
specified interface.
Error Message
%TBRIDGE-4-NOMEMORY: No memory available for transparent bridging
Explanation Packet memory was exhausted to the point that the few static buffers
required for transparent bridging cannot be allocated.
Recommended Action Diagnose memory utilization using the show buffers and
show memory commands.
Error Message
%TBRIDGE-4-NOVCDROP: Destination VC unknown for packet, (5 * ONESEC)
Explanation A transparently bridged packet destined for an ATM interface cannot be
fully addressed.
Recommended Action Clear the bridge table to force re-learning of all addresses.
Error Message
%TBRIDGE-4-NOVCFLOOD: No VC's configured for bridging on [chars],
(5 * ONESEC)
Explanation An ATM interface was configured for transparent bridging without also
specifying the associated virtual circuits.
Recommended Action Configure the required virtual circuits on the specified interface.
Error Message
%TBRIDGE-4-SMF_ACTION: invalid action found for [sci_notation] on
[chars] - [hex], (5 * ONESEC)
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
TCP Error Messages
Transmission Control Protocol error messages
Error Message
%TCP-2-ACCEPT: Callback failed to accept connection from [int]:[dec]
to [int]:[dec] -- discarding
Explanation An internal software error occurred.
Recommended Action If this message recurs, copy it down exactly as it appears and
contact your technical support representative for assistance.
Error Message
%TCP-6-BADAUTH:[chars] MD5 digest from [int]:[dec] to
[int]:[dec][chars]
Explanation The system received a TCP packet with an invalid MD5 authentication
digest on a connection endpoint. The message ends with the string "(RST)" if the incoming
packet was a TCP reset packet.
Recommended Action Determine why the source of the packet is not generating correct
digests on the connection. This could be due to either misconfiguration or security
weaknesses.
Error Message
%TCP-2-BUFFER: Tty[t-line], buffering bug
%TCP-2-PUTBYTE: Tty[t-line], tcp_putbyte() with
blocking disabled
Explanation An internal software error occurred.
Recommended Action If either message recurs, call your technical support
representative for assistance.
Error Message
%TCP-2-NOTREADY: [chars] called but TCP not initialized
Explanation An internal software error occurred.
Recommended Action If this message recurs, copy the message exactly as it appears and
contact your technical support.
Error Message
%TCP-6-NOTREADY: [chars] called but TCP not initialized
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TCP-6-TOOBIG: Tty[t-line], too many bytes of options([dec])
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
TMQ Error Message
Inbound terminal port queuing error message
Error Message
%TMQ-3-NOTFOUND: TMQ, Attempt to delete entry not in queue
Explanation An attempt was made to delete an entry not in the queue.
Recommended Action Advisory message only. No action required.
TN Error Messages
Telnet error messages
Error Message
%TN-2-BADLOGIN: Bad login string pointer [hex]
%TN-3-BADSTATE: Illegal state [dec]
%TN-3-READLINE: Unknown return code [dec] from telnet_readline()
Explanation An internal software error occurred.
Recommended Action If any message recurs, call your technical support representative
for assistance.
TN3270 Error Message
TN3270 error messages relate to the TN3270 protocol, a variation of the IBM VT (virtual terminal) protocol.
Error Message
%TN3270-2-INP_OVF1: Input Buffer overflow
Explanation A problem in TN3270 protocol was detected. Eight KB (8192) bytes of data
were received without a TN3270 end-of-packet indicator. The TN3270 buffer overflowed.
Recommended Action Copy this error message exactly as it appears, and contact your
technical support representative for assistance.
TR Error Messages
Token Ring error messages
Error Message
%TR-3-ADPCHK: Interface [chars], adapter check error [hex] [hex]
[hex] [hex]
Explanation The Token Ring monitor firmware detected a fatal error on the interface
card.
Recommended Action Issue a clear interface command. If this error recurs, copy the
error message exactly as it appears and contact your technical support representative for
assistance.
Error Message
%TR-3-ASYNCUSE: Unit [dec], [chars], async in use
Explanation Another internal process is communicating with the given Token Ring
interface.
Recommended Action Wait 1 minute and try again. If the condition persists, it probably
indicates an internal software error. Copy the message exactly as it appears, and report it
your technical support representative.
Error Message
%TR-4-BADADAPT: Unit [dec], adapter not responding
[hex] [hex][hex] [hex]
Explanation A Token Ring interface is not responding to initialization.
Recommended Action Confirm the Token Ring card's configuration, and make sure it is
in the correct slot. If the interface is in the correct slot, this message indicates a probable
hardware failure. Copy the message exactly as it appears, and report it your technical
support representative.
Error Message
%TR-3-BADBRDGPARMS: Unit [dec], bad bridge parameters:
bridge_num=[dec], max_rd= [dec]\nthisring=[dec],
targetring=[dec]
%TR-3-BADBUFFSIZE: Unit [dec], bad buffersize = [dec]
%TR-3-BADFIRM: Unit [dec], Tokenring firmware download
failed\n got [hex], expected [hex], at address
[hex].[hex]
%TR-3-BADFIRMTYPE: Unit [dec], bad firmware type code
during [chars]. type=[hex], fw=[hex]
%TR-3-BADFUNC: Unit [dec], bad functional
address=[hex], ring mode=[hex]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%TR-3-BADHEADER: RX - Unit [dec]: type [dec], size [hex], use [hex]
flags [hex]
Explanation The system detected corrupted data from the Token Ring interface card
(CSC2R/1R and CSC-R16M only). There may be a hardware problem.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%TR-3-BADMUL: Unit [dec], Can't set TR address to hardware multicast
address [enet]
Explanation An attempt was made to set the Token Ring interface MAC address to a
reserved multicast address.
Recommended Action Check your configuration. Make sure that your XNS and/or
Novell Token Ring addresses have not inadvertently been set to reserved multicast
addresses.
Error Message
%TR-3-BADRNGNUM: Unit [dec], ring number ([dec]) doesn't match
established number ([dec])
Explanation The number you have configured for the local ring does not match the value
currently in use on the ring.
Recommended Action Check the configuration to make sure you used the correct ring
number. If it is correct, confirm the configuration of all other bridges on the ring to make
sure they are using the same ring number.
Error Message
%TR-3-BADSLOT: Unit [dec], Slot [dec] does not exist.
Explanation This error message pertains only to the Cisco 4000. It is seen when software
tries to access (discover) a network interface module (NIM) that is not in slot 1, 2, or 3. The
software stalls trying to access the nonexistent slot. This message could indicate a card
error.
Recommended Action If this message recurs, call your technical support representative
for assistance or a replacement card.
Error Message
%TR-3-BADSTART: Unit [dec], Start completion and wrong
idb state -state= [dec]
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%TR-3-BADUNIT: Bad unit number [dec]
Explanation This error message pertains only to the IGS. When displayed, it indicates
that the system cannot find the chipset registers where it expects them to be. This is most
likely a hardware error.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance. It will be necessary to
determine the hardware unit configuration.
Error Message
%TR-4-BKGND: Unit [dec], bkgnd int: last packet out [dec]ms
%TR-4-BKGNDINT: Unit [dec], bkgnd int: [hex][hex]
[hex][hex][hex][hex] [hex][hex]
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, call your technical support
representative for assistance.
Error Message
%TR-3-BOGUSDATA: [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex]
Explanation This message displays the first eight bytes of frame data if the data length is
invalid. It is the second part of the "%TR-3-BOGUSLENGTH" error message that follows.
Recommended Action See recommended action for the "%TR-3-BOGUSLENGTH"
error message.
Error Message
%TR-3-BOGUSLENGTH: Unit [dec], bad input length [dec], [chars] code.
Explanation This is the first message displayed when the frame data length is invalid. It
is unique to the CSC-R16 Token Ring card for all system versions.
Recommended Action Display of both the "%TR-3-BOGUSLENGTH" and
"%TR-3-BOGUSDATA" error messages indicates a serious problem on the interface
between the Token Ring chipset, the SBE16 card, and the system driver. Copy the message
exactly as it appears, and report it your technical support representative.
Error Message
%TR-3-COMPFAIL: Unit [dec], Tbuf completion failure,
result [hex]
%TR-3-FILTFAIL: Unit [dec], SRB filter set failed:
[hex] [hex][hex] [hex] (blk [hex]) downing
%TR-3-GETCONF: Unit [dec], get_config failed, result
[hex] [hex]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%TR-3-DIAGFAIL: Interface [chars] failed init diags [hex] [hex],
[chars]
Explanation The microcode attempted to run its diagnostics on the chip and failed.
Recommended Action Issue a clear interface command. If this error recurs, copy the
error message exactly as it appears and contact your technical support representative for
assistance.
Error Message
%TR-3-INCOM: Unit [dec], incompatible firmware: system
[hex],interface [hex]
Explanation The Token Ring interface contains firmware that is incompatible with the
system software.
Recommended Action Call your technical support representative to upgrade the Token
Ring Monitor firmware, the system software, or both.
Error Message
%TR-3-INITFAIL: Unit [dec], init failed. result
code=[hex], error code=[hex]
Explanation The Token Ring hardware failed to initialize properly.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TR-4-INTFAIL: Unit [dec] interface failure: [hex]
[hex] [hex],idb state [dec]
Explanation The Token Ring Monitor firmware detected a fatal error due either to an
internal software problem or to a hardware failure.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TR-3-MADGETX: Unit [dec], lost packet using Transmit
Descriptor.
Explanation This error message pertains only to the Cisco 4000. When displayed, it
indicates that a packet was lost inside the Madge firmware, and the software lost the pointer
to it.
Recommended Action This message indicates a software problem on the card. If this
message recurs, call your technical support representative for assistance or a replacement
card.
Error Message
%TR-3-MODEFAIL: Unit [dec], change mode failed. result code=[hex],
error code=[hex]
%TR-3-MODFAIL: Unit [dec], tra_modify failed, result
[hex] [hex]
%TR-3-NOFIRM: Unit [dec], no TMS380 firmware present. eagle=[hex],
magic=[hex]
Explanation An internal hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TR-3-NOMEMORY: Unit [dec], no memory for [chars]
Explanation The requested operation could not be accomplished because of a low
memory condition.
Recommended Action Reduce other system activity to ease memory demands. If
conditions warrant, upgrade to a larger memory configuration.
Error Message
%TR-4-NOMOREPAGES: Unit [dec], Out of Pages for [chars].
Explanation This error message pertains only to the Cisco 4000.When displayed, it
indicates that the ability to switch the receive buffers for the Token Ring was halted due to
an insufficient amount of memory.
Recommended Action Reduce other system activity to ease memory demands and then
reset the Token Ring interface by entering a clear interface tokenring command. If these
actions do not solve the problem, upgrade to a larger memory configuration or call your
technical support representative for assistance.
Error Message
%TR-3-NOPAK: Unit [dec], Tbuf completion and no pakout
Explanation An internal hardware or software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%TR-3-OLDTRIF: Obsolete firmware in multibus TR unit [dec] - does
not support fast switching
Explanation A firmware upgrade is needed.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%TR-3-OPENFAIL: Unit [dec], open failed: check the lobe cable DB-9
connection
Explanation The Token Ring interface was unable to insert itself into the ring. This is an
indication of a busy or broken ring. The first character string in this error message indicates
the stage of initialization at which the error occurred, and the second describes the error.
Recommended Action Try to open the interface again. This generally can be
accomplished by issuing the clear interface tokenring command. If the error message
recurs, call your technical support representative for assistance.
Error Message
%TR-3-OPENFAIL2: Unit [dec], open failed: check the lobe cable
connection.
Explanation The Token Ring interface was unable to insert itself into the ring, and the
error code returned indicates a wiring problem.
Recommended Action Check the cable connecting the router to the Token Ring MAU,
and try to open the interface again. This generally can be accomplished by issuing the
clear interface tokenring command. If the error message recurs, call your technical
support representative for assistance.
Error Message
%TR-3-PANIC: Unit [dec], panic [hex] [hex] [hex]
Explanation The Token Ring monitor firmware detected a fatal error that indicates an
impending interface failure.
Recommended Action Copy the error message and the interface message exactly as they
appear and then report them to your technical support representative.
Error Message
%TR-3-PANICINF: Unit [dec], PI [hex] [hex] [hex] [hex][hex] [hex]
Explanation This message is similar to the "%TR-3-PANIC" error message, but indicates
a nonfatal error. This message appears in very unusual situations that should not arise in
normal operation.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TR-3-PANICTYPE: Unit [dec], [chars] error
Explanation This message is similar to the %TR-3-PANIC error message, but indicates a
nonfatal error. This message appears in very unusual situations that should not arise in
normal operation.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%TR-3-RESETFAIL: Unit [dec], reset failed, error code [hex]
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%TR-3-RESETFAIL2: Unit [dec], reset failed, auxiliary processor init
failed
Explanation This message isolates a particular RESETFAIL condition from several other
reset failure conditions. It is unique to the CSC-R16 Token Ring card for all system versions
and indicates a state problem.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%TR-3-RIFBADMAGIC: Invalid magic number ([hex]) in
RIF [chars] table entry [hex]
%TR-3-RIFTBLTRASH: Trashed [chars] RIF table entry [hex] found and
zeroed
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%TR-3-SETBRIDGEFAIL: Unit [dec], set bridge failed (code %#x)
Explanation A hardware error occurred. The source routing accelerator (SRA) chip on
the Token Ring card could not be initialized.
Recommended Action A replacement card might be needed. Copy the message exactly
as it appears, and contact your technical support representative for assistance.
Error Message
%TR-3-SETFAIL: Unit [dec], couldn't set interface to
physical address [enet]
Explanation An illegal MAC address was specified for this interface.
Recommended Action Normally the Token Ring interface uses the burned-in address
contained in a PROM on the board. However, certain protocol stacks require the MAC
address to be modified to an illegal value. Check your configuration for possible problems.
If this message recurs, call your technical support representative.
Error Message
%TR-3-SETFUNFAIL: Unit [dec], set functional address
failed (code [hex])
%TR-3-SETGRPFAIL: Unit [dec], set group address
failed (code [hex])
%TR-3-SETOPTFAIL: Unit [dec], set open options failed
(code [hex])
%TR-3-SMTSTATFAIL: Unit [dec], get_smt: get smt
stats failed - result [hex]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%TR-4-SNKBRIDG: Unit [dec], removing invalid bridge
Explanation The system could not start a Token Ring source-route bridge because the
interface in question does not have the appropriate Token Ring Monitor firmware or
hardware.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%TR-3-STARTFAILED: Unit [dec], start failed, result
[hex],reason [hex]
Explanation The Token Ring Monitor firmware attempted to insert the system into the
ring, and the chipset detected a nonstandard fatal error.
Recommended Action This message indicates a problem with the Token Ring chipset
hardware. Copy the message exactly as it appears, and report it your technical support
representative.
Error Message
%TR-3-STARTFAILED2: Unit [dec], start failed,
auxiliary processor init failed.
Explanation This error message isolates a particular STARTFAIL condition from several
other reset failure conditions. It is unique to the CSC-R16 Token Ring card for all system
versions and indicates a state problem.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%TR-6-STATE: TR[dec]: Ring Status: [chars]
Explanation This message is displayed when the Token Ring's status changed as
determined by the chipset. This information also is used to automatically determine
whether the interface is still usable to propagate network traffic.
Recommended Action Informational message only. No action required.
Error Message
%TR-3-STATFAIL: Unit [dec], get_static: get stats
failed - Async: [hex] [hex] [hex] [hex]
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%TR-6-STATRING: TR[dec]: Ring Status: [chars] [chars] ([hex]) LIV
[hex]
Explanation This message is displayed when the Token Ring's status changed as
determined by the chipset. This information also is used to automatically determine
whether the interface is still usable to propagate network traffic. The meaning of each status
code is shown in .
Recommended Action Check the Token Ring for the indicated condition.
Table 5 Token Ring Status Codes
Code
|
Explanation
|
Fatal
|
0x8000
|
Signal loss
|
Yes
|
0x4000
|
Hard error
|
Yes
|
0x2000
|
Soft error
|
No
|
0x1000
|
Transmit beacon
|
Yes
|
0x0800
|
Lobe wire fault
|
Yes
|
0x0400
|
Auto removal error
|
Yes
|
0x0100
|
Receive request removed
|
Yes
|
0x0080
|
Counter overflow
|
No
|
0x0040
|
Single station
|
No
|
0x0020
|
Ring recovery
|
No
|
Error Message
%TR-3-TRACMD: tra_cmd: unit [dec] bad state: cmd [hex]
[hex],result [hex] [hex] (blk [hex], iob
[hex])
%TR-4-UNKNOWNCOMP: Unit [dec], Unknown command
completion:cmd [hex], rslt [hex]
%TR-3-UNKNOWNT2M: Unit [dec], Unknown t2m command
[hex] [hex]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%TR-3-WIREFAULT: Unit [dec], wire fault: check the
lobe cable MAU connection
Explanation The Token Ring hardware is reporting a wire fault condition.
Recommended Action Check the cable connecting the router to the Token Ring media
attachment unit (MAU).
TUN Error Messages
Tunnel error messages
Error Message
%TUN-4-BADOUTMODE: Interface [chars] unsupported output mode [dec]
[chars]
Explanation The tunnel interface was set to an encapsulation mode that is not supported.
Recommended Action Report the problem to your technical support representative and
correct your configuration.
Error Message
%TUN-4-RECURDOWN: [chars] temporarily disabled due to recursive
routing
Explanation When routing the same payload protocol over a carrier protocol (tunneling
IP over IP, for example), it is possible to misconfigure your network so that you will try to
route to the tunnel destination address via the tunnel. This is usually caused by a
misconfiguration of the tunnel or a temporary instability due to route flapping elsewhere in
your network. It is important to take steps to ensure that routing information between the
carrier networks and the payload networks is not allowed to mix. If the router discovers a
recursive routing problem, it will temporarily shut down the tunnel interface for a few
minutes so that the situation that is causing this problem can resolve itself as routing
protocols converge. If the problem is caused by misconfiguration, the link may oscillate
indefinitely.
Recommended Action No action required.
Error Message
%TUN-4-RECURSHUT: [chars] administratively disabled due to recursive
routing
Explanation If the recursive routing situation reported by the RECURDOWN message is
not cleared up after ten bounces, the tunnel interface will be administratively shut down to
avoid further flapping.
Recommended Action Determine the cause of the recursive routing situation, correct it,
and then manually bring the interface back up using the no shutdown command.
UCODE Error Messages
Microcode error messages
Error Message
%UCODE-3-BADCHKSUM: Bad checksum in [chars], found [hex] expected
[hex]
Explanation The microcode file is corrupted in some way; the checksum computed after
reading the file from Flash does not match the one in the file. The file will not be
downloaded, and the onboard ROM microcode will be used instead.
Recommended Action Reload the microcode. If the message recurs, call your technical
support representative for assistance.
Error Message
%UCODE-3-BADHWVER: Ucode file [chars] requires [chars] version
[dec].x hardware
Explanation A mismatch was detected during an attempt to load a microcode file into an
interface processor. The hardware requires a different version than the one specified.
Recommended Action Use the required microcode version.
Error Message
%UCODE-3-HDRCORRUPT: Ucode header corrupted in [chars], found [hex]
expected [hex]
Explanation The microcode file is corrupted in some way; the checksum computed after
reading the file from Flash does not match the one in the file. The file will not be
downloaded, and the onboard ROM microcode will be used instead.
Recommended Action Reload the microcode. If the message recurs, call your technical
support representative for assistance.
Error Message
%UCODE-3-IPCBUFFAIL: Unable to obtain IPC resources
Explanation The InterProcess Communication (IPC) service used to download
microcode to certain interface processors has failed to obtain a buffer. Certain interface
processors will not load properly.
Recommended Action Try the reload command again. If this error recurs, copy the error
message exactly as it appears and contact your technical support representative for
assistance.
Error Message
%UCODE-3-IPCINITFAIL: Unable to initialize IPC [chars] services
Explanation The InterProcess Communication (IPC) service used to download
microcode to certain interface processors has failed to initialize. Certain interface
processors will not load properly.
Recommended Action Reload the router.
Error Message
%UCODE-3-IPCINVALID: Invalid IPC request [dec] received from [hex]
Explanation The InterProcess Communication (IPC) service used to download
microcode to certain interface processors has received an invalid message.
Recommended Action Verify that the proper revisions of code are selected.
Error Message
%UCODE-3-LDFAIL: Unable to download ucode [chars] in slot [dec],
installed ucode loaded
Explanation For some reason, the microcode file specified by the configuration is not
suitable for downloading, or another error occurred. The onboard ROM microcode will be
loaded so the interface can remain operational.
Recommended Action Attempt to reload the microcode. If the message recurs, call your
technical support representative for assistance.
Error Message
%UCODE-3-NOBUF: Unable to allocate memory for ucode buffer
Explanation A buffer is required to decompress microcode before loading it into an
interface processor. This buffer could not be allocated for some reason.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%UCODE-3-NOFILE: Ucode file [chars] not found, installed ucode
loaded in slot [dec]
Explanation The file specified by the configuration was not found in Flash. The onboard
ROM microcode will be loaded so the interface can remain operational.
Recommended Action Use show flash to determine if the file is located in Flash. If the
file is there, attempt to reload the microcode. If the message recurs, call your technical
support representative for assistance.
Error Message
%UCODE-3-NOROM: Invalid attempt to load ROM ucode in slot [dec]
Explanation Some interface processors cannot load microcode from ROM.
Recommended Action Remove the erroneous configuration statement.
Error Message
%UCODE-5-OBSOLETE: FDDI unit [dec] has obsolete microcode: please
upgrade it
Explanation This message occurs when an FDDI interface processor is found running
microcode that does not support microcode CMT, which is required for all software
releases from 10.2 on.
Recommended Action Upgrade the microcode on the interface processor.
Error Message
%UCODE-3-OLDHARD: Ucode file [chars] requires [chars] version
[dec].[dec] hardware or later
Explanation The microcode specified requires a more recent version of the hardware than
it found. The onboard ROM microcode will be loaded instead.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%UCODE-3-RDFAIL: Unable to read ucode file [chars] from flash
Explanation For some reason, the microcode file was not read from Flash. Flash might be
locked by another process or otherwise unavailable.
Recommended Action Use the show flash command to determine whether Flash is in
use and issue another microcode reload when Flash is free. If the message recurs, call your
technical support representative for assistance.
Error Message
%UCODE-3-TOOBIG: File [chars] at length [dec] is too long for buffer
size [dec]
Explanation The file is too large for the buffer. The onboard ROM microcode will be
loaded.
Recommended Action If the error message recurs after the onboard ROM microcode is
loaded, call your technical support representative for assistance.
Error Message
%UCODE-3-VERSIONCK: Inappropriate version [dec].[dec] for [chars]
Explanation An attempt was made to load an inappropriate version of microcode.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%UCODE-3-WRONGHARD: [chars] is [chars] ucode not [chars],
microcode/hardware mismatch
Explanation The specified microcode file is for a different interface processor than
specified in the configuration. The user has made a configuration error. The onboard ROM
microcode will be loaded.
Recommended Action Reenter your microcode configuration command after
confirming the interface type and reload the microcode.
UNIX Error Message
UNIX error message
Error Message
%UNIX-1-SYSABORT: System aborted
Explanation The system abnormally terminated.
Recommended Action Record the output from the following commands:
•
show process memory (repeated twice)
•
show memory
•
show buffers
•
show version
•
show running-config
Provide this information and the error message to your technical support representative.
UTIL Error Messages
Utility error messages
Error Message
%UTIL-3-RANGEINCON: internal inconsistency [dec] [hex]
Explanation A fatal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%UTIL-2-RANGERET: list [hex] no memory, can't return range [dec]
[dec]
Explanation A memory overflow error occurred.
Recommended Action Investigate memory usage. If memory usage is abnormal, call
your technical support representative for assistance. Otherwise, increase router memory.
Error Message
%UTIL-2-RANGEDUP: list [hex] already contains range [dec] [dec]
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%UTIL-3-RANGEINVERT: list [hex] low [dec] > high [dec]
Explanation A software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%UTIL-3-RANGENULLINPUT: null pointer input to range function
Explanation An attempt was made to access a range function with a NULL pointer.
The range list creation failed.
Recommended Action Review the error log for a corresponding memory allocation
failed message. Copy the error message exactly as it appears, and report it to your technical
support representative.
Error Message
%UTIL-3-TREE: Data structure error--[chars], ONEMIN
Explanation A software error occurred, resulting in a data structure inconsistency.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative. Ask for their assistance in obtaining a version of code with
the error fixed.
VINES Error Messages
Banyan Virtual Integrated Network Service error messages
Error Message
%VINES-2-BADPARAM: [chars] called with [chars] parameter set to
[chars]
Explanation One of the VINES lookup functions was called with an illegal argument.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-BADTIMER: RTP timer for [chars] was found disabled, and was
reset., 10*ONESEC
Explanation An internal interface timer is not running. This condition usually occurs after
an interface reset.
Recommended Action None. The system automatically restarts the timer.
Error Message
%VINES-2-CACHEFAILED:Cannot build cache entry ([dec] bytes) for
[v-name] on [chars]
Explanation The cache population routing for VINES fast switching determined that the
MAC header on a packet is too large to fit into the cache.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-CACHEUNSUPP: Caching of [chars] not supported on [chars]
Explanation The cache population routing for VINES fast switching was called for an
interface that does not support VINES fast switching.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-CONSISTENCY: Error [chars]
Explanation The VINES code ran into a situation that should not happen. For example,
an IPC port number needs to be allocated, but all 65,535 port numbers are currently in use.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-CORRUPTENTRY: Detected a corrupted entry in the [chars]
table
Explanation The VINES code detected that an internal table entry was corrupted.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-DUPADDR: Duplicate address detected on interface [chars]
Explanation The router detected that its VINES address is being used by another router.
Recommended Action Identify the other router that is using this address by manual
inspection of the routers. Issue the command vines routing recompute on both routers. If
a router does not support the recompute keyword, then on that router you must disable
VINES, write the configuration to memory, reboot the router, and then reconfigure VINES.
Error Message
%VINES-2-ENCAPFAILED: Encapsulation failed for [v-name] via [v-name]
on [chars]
Explanation The cache population routing for VINES fast switching encountered an
encapsulation failure when building a cache entry for a neighbor.
Recommended Action Examine your configuration for causes of the encapsulation
failure. Look for missing map statements, interfaces that have gone down, and so on.
Error Message
%VINES-6-FNNOTFOUND: [chars] service [chars] routine missing [chars]
vector.
Explanation There is an inconsistency in the static VINES data structures for handling
application-layer packets.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-INIT: Init code for [chars] doesn't match defined
constant., 10*ONESEC
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VINES-2-INVALIDPATH: Bad [chars] in path for neighbor entry
[v-name]
Explanation While searching the neighbor table, the code determined that a pointer that
should point to a VINES path structure actually points to some other structure.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-INVALIDROUTE: Bad [chars] in route for server entry
[v-name]
Explanation While searching the routing table, the code determined that a pointer that
should point to a VINES route structure actually points to some other structure.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-6-IPCNOROUTINE: IPC port [dec] registered without an upcall
[chars]
Explanation There is an inconsistency in the active VINES data structure for handling
IPC DATA messages. A message was received for a port that should have a listener, but the
listener routine cannot be found.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-NEIGHBOR: vines_update called with null
neighbor
Explanation An internal software error occurred.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
Error Message
%VINES-2-NOBUFFERS: No buffers available for [chars]
Explanation There were no buffers available to send a packet.
Recommended Action Examine your system for memory or buffer leaks.
Error Message
%VINES-2-NOMEMORY: No memory available for [chars]
Explanation The requested operation could not be accomplished because of a low
memory condition.
Recommended Action Reduce other system activity to ease memory demands. If
conditions warrant, upgrade to a larger memory configuration.
Error Message
%VINES-2-NOVENCAP: Encapsulation failed on [chars], no vencap
routine
Explanation The VINES code tried to send a packet on an interface that does not have a
new encapsulation routine.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-2-REASSEMBLY: SRTP reassembly code returned invalid result
code [dec]., 10*ONESEC
Explanation An internal software occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VINES-6-RPCNOSERVICE: IPC port [dec] registered without a service.
Explanation There is an inconsistency in the active VINES data structure for handling
Net RPC messages. A message was received for a port that should have a service
description, but that service description cannot be found.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%VINES-6-RTNNOTFOUND: [chars] service [chars] routine not found
while [chars].
Explanation There is an inconsistency in the active VINES service description data
structures. A service handler routine cannot find the description of its own service.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
VIP Error Messages
Versatile Interface Processor error messages
Error Message
%VIP-3-BADMALUCMD: Unsupported MALU command [dec], arg=[hex],
pascb=[hex]
Explanation The Route Processor (RP) or the Route/Switch Processor (RSP) passed
down a command that the software was not prepared to handle.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VIP-3-CMDNOPASCB: PASCB Null for command [dec], arg=[hex]
Explanation The Route Processor (RP) or the Route/Switch Processor (RSP) passed
down a command that the software was unprepared to handle.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VIP-3-NODISPATCH: Dispatch vector Null, cmd=[dec], dintf=[dec]
Explanation No command dispatch vector was found for the specified interface.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VIP-2-NOICBS: msg_noicbs
Explanation No Switch Processor (SP) interrupt control block structure was associated
with the port adaptor or the interface.
Recommended Action Copy the error message exactly as it appears, and report it to your
technical support representative.
Error Message
%VIP-3-UNDEFIDBTYPE: Undefined idb type [dec]
Explanation This message is sent from the VIP kernel when it sees a media type other
than Ethernet, Token Ring, or serial. These are the media types supported by Cisco IOS
Release 11.2 on the VIP. The message might be caused by having an older version of the
software running on a device with a new VIP port adapter.
Recommended Action Check whether the version of the software being run supports the
VIP port adapter. If an old software version does not appear to be the problem, copy the
error message exactly as it appears and report it to your technical support representative.
X25 Error Messages
X.25 error messages
Error Message
%X25-3-ADDRESSBAD: Interface [chars], x25 address [chars] subaddress
[char] is too long, X25_COMPLAIN_LEVEL
Explanation This message occurs when a subaddress is configured. When this subaddress
is combined with the interface's X.121 address, the total address exceeds the limit of 15
characters.
Recommended Action Reconfigure the subaddress so that this does not happen.
Error Message
%X25-3-BADCONFIG: Interface [chars], X.25 [chars], current
configuration retained.
Explanation The interface's X.25 configuration is not valid; the existing configuration
was not changed.
Recommended Action Verify the following:
•
The interface's switched virtual circuit ranges do not overlap; for nonzero values, lic <= hic < ltc <= htc < loc <= hoc. (For more information, refer to "Configuring Virtual Circuit Ranges" in the Router Products Configuration Guide.)
•
If an incoming-only range is defined, check that it is numerically less than the two-way range.
•
If an outgoing-only range is defined, check that it is numerically greater than the two-way range.
•
No virtual circuit high/low parameter is zero unless its partner
low/high parameter is also zero.
•
The default window sizes are less than the interface modulo.
Error Message
%X25-4-BADMBIT: Interface [chars], VC [dec], partial data packet has
M-bit set
Explanation This message occurs when a virtual circuit is set up using the default
maximum packet sizes, but the DTE and DCE are not configured with the same default
values. A packet was received that had the M-bit set, signifying that more data follows, but
the packet did not carry the maximum number of bytes allowed. Such partial data packets
must have the M-bit cleared. The resulting loss of a message boundary might cause
problems for the data recipient.
Recommended Action Verify the default flow control parameters of the DTE and the
DCE. If this error recurs, copy the error message exactly as it appears and contact your
technical support representative for assistance.
Error Message
%X25-4-BADUPCALL: Interface [chars], Unexpected call
([chars]) from LLC2 DTE= [enet]
%X25-4-DEBUG_LCI: LCI deleted at interrupt time
%X25-2-ILLP4: Interface [chars], Illegal state [chars]
when P4
%X25-3-INTIMEQ: Interface [chars], LCN [dec] already in
timer queue, new time [dec]
%X25-3-NOLCI: Interface [chars], Delete: lci [dec] not
found in [chars] table
%X25-3-NOTFINDBH: Can't find bfe host address [inet] to
delete
%X25-3-NOTFINDI: Can't find address [inet] to delete
%X25-3-NOTFINDS: Can't find address [chars] to delete
%X25-3-SPURD1: Spurious D1 timer wakeup on LCI [dec]
Explanation An internal software error occurred.
Recommended Action If any of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.
Error Message
%X25-3-COMPERR: Interface [chars] LCI [dec] low-level stac
compression error, X25_COMPLAIN_LEVEL
Explanation A Stacker compression algorithm internal error or shortage of buffer space
was encountered during a compression operation. This should never happen.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-4-LARGEPKSIZE: Interface [chars], [chars] packet sizes
[dec]/[dec] too large; lower values will be negotiated.
Explanation The interface's default packet sizes or outgoing packet size facility values
are too large to be carried by Link Access Procedure, Balanced (LAPB).
Recommended Action The router will negotiate lower packet size values automatically.
The LAPB N1 value should be increased. For example, for an X.25 maximum packet size
of 1024, modulo 8 X.25 operation will add 3 bytes of overhead and modulo 8 LAPB
operation will add 4 bytes of overhead (the two bytes of CRC are defined to be included).
This means that N1 must be at least 1031 bytes * 8 = 8248.
Error Message
%X25-3-LCIBOGUS: in x25_timer NULL lci-idb [hex]
Explanation An internal software error occurred.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-5-NOBUF: Interface [chars] LCI [dec] [chars]
Explanation This is a warning only (the compressed packet was not lost). However, an
X.25 packet layer RNR (wait) was generated and packet-level transmission on the LCN will
not resume (RR issued) until a decompression buffer becomes available.
Recommended Action If this message occurs frequently, you may need to modify the
buffer pool. Copy the message exactly as it appears, and report it your technical support
representative.
Error Message
%X25-5-NOMEM: Interface [chars] LCI [dec] NO memory for dictionary
Explanation The 14K PBP history dictionaries could not be allocated. PBP compression
is not enabled.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-4-PARTIALMAP: Interface [chars], [chars] encapsulation call
from [chars] partially mapped to [chars]
Explanation An incoming X.25 call specified a protocol that was assigned to a
multiprotocol map; the VC will not be able to carry the full set of protocols specified by the
map.
Recommended Action Modify the configuration of the router or the far host to match the
encapsulation method used.
Error Message
%X25-5-PBPDBIT: Interface [chars] LCI [dec] PBP Compression does not
support X25 D bit, X25_COMPLAIN_LEVEL
Explanation Compression is not enabled because D-bit support is configured for the LCI.
Recommended Action Reconfigure without D-bit support, or do not attempt to run with
compression.
Error Message
%X25-5-PBPHOLDQ: Interface [chars] LCI [dec] X25 Hold queue needs to
be at least default size, X25_COMPLAIN_LEVEL
Explanation An attempt was made to configure the X.25 hold queue to less than the
minimum value.
Recommended Action Configure the X.25 hold queue to be 10 or more.
Error Message
%X25-5-PBPNOEND: Interface [chars] LCI [dec] End system not configed
for X25 PBP, X25_COMPLAIN_LEVEL
Explanation A compression or decompression operation was attempted by a router other
than an end router. Only end routers can perform compression and decompression.
Recommended Action Reconfigure the routers so that only the end routers in the
network perform compression and decompression.
Error Message
%X25-3-PVCBAD: Interface [chars], PVC [dec], [chars]
Explanation A switched PVC cannot be connected. The final [chars] text string in the
message represents the state of the PVC. These text strings can also appear in show x25-vc
output. For more information, refer to the show x25-vc documentation in the Router
Products Command Reference publication.
Recommended Action Validate the configuration of the PVCs at both ends of the
connection, and reconfigure them if necessary.
Error Message
%X25-3-PVCDELETE: LCI for PVC [dec] being deleted!
Explanation A PVC was using an x25 map entry that was deleted or the interface
configuration changed to make the PVC number illegal; this forces the deletion of the PVC.
Recommended Action No action required. Note that some attached equipment may
object to an inability to use the deleted PVC.
Error Message
%X25-4-RANGEUNUSED: Interface [chars], [chars] VC range
unused; set limits to zero
Explanation An outgoing-only or incoming-only virtual circuit range exactly overlaps the
two-way virtual circuit range. This was the former method for specifying that a virtual
circuit range was not used. The current method is to set the range limits to zero.
Recommended Action Use the privileged copy running-config startup-config
command to write the configuration to memory. This will store the modified (zero) range
limits.
Error Message
%X25-3-SIZEBAD: Interface [chars] LCI [dec] Decompression size error
Explanation An internal software error occurred. The PBP header has an uncompressed
packet size field. Each uncompressed packet size is checked against this field.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-3-SYNCBAD: Interface [chars] LCI [dec] Decompression sync
error. Expected [dec], got [dec]
Explanation An internal software error occurred. The PBP header has a sync field. The
sync field (8 bits) is checked on each received packet.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-4-VCLOSTSYNC: Interface [chars], VC [dec] TCP connection
[chars]
Explanation An X.25 circuit that is being tunneled over a TCP connection between
routers was cleared ungracefully. The last [chars] text string in the message can take one of
two forms. If the text string is "closed unexpectedly," the router at the remote end of the
connection was rebooted, or the connection failed. If the text string is "connection
corrupted," it is likely that the connection was made to a router running an older software
release.
Recommended Action If the text string is "closed unexpectedly," reestablish the
connection after the remote router or intervening network is operational. If the text string
is "connection corrupted," upgrade the router at the other end of the connection to a more
recent software release.
Error Message
%X25-3-VERSIONBAD: Interface [chars] LCI [dec] Compression Version
mismatch. Expected [hex]; received [hex]
Explanation An internal software error occurred. The PBP header has a mismatched
version field. The version is checked on each received packet.
Recommended Action Copy the message exactly as it appears, and report it your
technical support representative.
Error Message
%X25-3-XOTPROTOCOL: XOT protocol error from [inet]: [chars]
Explanation A protocol error was detected over an X.25-over-TCP (XOT) connection,
causing the connected VC to close. A flaw may exist in the remote host's XOT
implementation.
Recommended Action If this error recurs, copy the error message exactly as it appears
and contact your technical support representative for assistance.
XNS Error Messages
Xerox Network Systems error messages
Error Message
%XNS-3-BADPATHS: Invalid number of paths ([dec]) for [dec]
%XNS-2-BADROUTE: Error [chars] route - null table
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, copy the message exactly as it
appears and contact your technical support representative for assistance.