Cisco 11000 Series CSS Hardware Installation Guide (Software Version 6.10)
Specifications

Table Of Contents

Specifications

Electrical Specifications

AC Power Cord Country Requirements

Environmental Specifications

Physical Specifications

Module Specifications

Internal Disk Module Specifications

IDM Power Requirements

IDM General Specifications

Supported Protocols

Transport

Network

Routing

Gateway

Application

Network Utilities

Network Management

DC Power Supply Safety Warnings

Lithium Battery Disposal Warnings


Specifications


This appendix contains the following major sections that list specifications for the Cisco 11000 Series Content Services Switches (CSS 11050, CSS 11150, and CSS 11800):

Electrical Specifications

Environmental Specifications

Physical Specifications

Module Specifications

Internal Disk Module Specifications

Supported Protocols

DC Power Supply Safety Warnings

Lithium Battery Disposal Warnings

Electrical Specifications

Table A-1 describes the CSS 11050, CSS 11150, and CSS 11800 AC electrical specifications.


Note The specification for the CSS 11800 is for the system, not per power supply.


Table A-1 AC Electrical Specification

AC Specification
CSS 11050 or CSS 11150
CSS 11800

Input Voltage AC

100 to 240 VAC
50 to 60 Hz

100 to 240 VAC
50 to 60 Hz

Current AC (max@ 100VAC)

3.1 Amps

12 Amps

Power Consumption
(maximum)

310 Watts

1200 Watts

Heat Dissipation

683 BTU/hr

3073 BTU/hr


Table A-2 describes the CSS 11150 and CSS 11800 DC electrical specifications.


Note The specification for the CSS 11800 is for the system, not per power supply.


Table A-2 DC Electrical Specifications

DC Specification
CSS 11150
CSS 11800

Voltage DC

-48.0 to -60.0 VDC

-48.0 to -60.0 VDC

Current DC (maximum)

8 Amps

25 Amps

Power Consumption
(maximum)

300 Watts

970 Watts

Heat Dissipation

683 BTU/hr

3073 BTU/hr


AC Power Cord Country Requirements

The CSS AC power cord is a three-prong IEC 320-C13 plug that grounds the unit and polarizes the connection. Table A-3 lists country requirements for plug types and ratings.

Table A-3 AC Power Cord Country Requirements

Country
AC Power Cord Type and Rating

Australia

AS 3112-1981 10A/240 VAC

Austria

CEE7 Sht V11 16A/240 VAC

Belgium

CEE7 Sht V11 16A/240 VAC

British

BS 1363A 13A/250 VAC

Canada

NEMA 5-15P 12A/125 VAC

China

AS 3112-1981 10A/240 VAC

Denmark

SRAF 1962/DB 16/87 10A/250 VAC

Finland

CEE7 Sht V11 16A/240 VAC

France

CEE7 Sht V11 16A/240 VAC

Germany

CEE7 Sht V11 16A/240 VAC

India

BS 546A 16A/250 VAC

Israel

S.I. 32 16A/250 VAC

Italy

CEI 23-16 10A/250 VAC

Japan

JIS 8303 12A/125 VAC

Netherlands

CEE7 Sht V11 16A/240 VAC

Norway

CEE7 Sht V11 16A/240 VAC

South Africa

BS 546A 16A/250 VAC

Sweden

CEE7 Sht V11 16A/240 VAC

Switzerland

ASE 1011 (1959) Type 12 10A/250 VAC

U.S.A.

NEMA 5-15P 12A/125 VAC


Environmental Specifications

Table A-4 describes the CSS 11050, CSS 11150, and CSS 11800 environmental specifications.

Table A-4 Environmental Specifications

Specification
CSS 11050 or
CSS 11150
CSS 11800

Ambient Operating Temperature

32 to 104° F (0 to 40° C)

Relative Humidity

5 to 95% (non-condensing)

Ambient Storage Temperature

23 to +149° F (-5 to 65° C)


Physical Specifications

Table A-5 describes the CSS 11050, CSS 11150, and CSS 11800 physical specifications.

Table A-5 Physical Specifications

Specification
CSS 11050 or CSS 11150
CSS 11800

Chassis Dimensions (H x W x D)

2.62" x 17.1" x 15"

25.25" x 17.1" x 12.5"

Chassis Shipping Weight

23 lbs.

105 lbs. (base system containing one power supply, one SFM or SFM2, one SCM, IDM)

Chassis Weight Fully Configured

16 lbs.

72 lbs. (base system containing one power supply, one SFM or SFM2, one SCM, IDM)


Module Specifications

Table A-6 describes module general specifications.

Table A-6 Module General Specifications

Specification
CSS 11050 or CSS 11150
CSS 11800

Slot Configuration

Fixed configuration

8 slots for I/O modules
2 slots for SCMs
(1 active, 1 passive)
4 slots for SFMs or SFM2s (2 active, 2 passive)
1 slot for the IDM

Switch Bandwidth

5 GB

20 GB (base)
20 GB 1:1 optional redundancy

CPU Memory (DRAM)

CSS 11050
128 MB

CSS 11150
128 MB (base) with a maximum of 256 MB

Switch Control Module
128 MB

Switch Fabric Module (SFM or SFM2)
256 MB (128 MB per Switch Fabric Processor)

Common Packet Memory (SRAM)

Per System
6 MB

Switch Control Module Per System
12 MB


Internal Disk Module Specifications

This section provides the following specifications for the Internal Disk Module (IDM).

Power

General

IDM Power Requirements

Table A-7 describes the IDM power requirements.

Table A-7 IDM Power Requirements

Power Requirements
Internal Disk Module

+12V +/- 5%

1.2 Amps Max

+5V +/- 5%

.5 Amps Max


IDM General Specifications

Table A-8 defines IDM general specifications.

Table A-8 IDM General Specifications

Specification
Hard Disk
Flash Disk

Capacity

1.08 GB minimum

350 MB minimum

Interface

EIDE or ATA-3

IDE


Supported Protocols

The CSS supports the following protocols:

Transport

Network

Routing

Gateway

Application

Network Utilities

Network Management

Transport

The CSS supports the following transport protocols:

TCP

UDP

Network

The CSS supports the following network protocols:

Internet Protocol (IP)

ICMP

Address Resolution Protocol (ARP)

Inverse ARP

Routing

The CSS supports the following routing protocols:

RIP I

RIP II

OSPF Version 2

Gateway

The CSS supports Network Address Translation (NAT), per RFC 1631 gateway protocol.

Application

The CSS supports the following application protocols:

HTTP 1.0, HTTP 1.1

TELNET

FTP, TFTP

RTP

Network Utilities

The CSS supports the following network utility protocols:

DNS Client

Radius Client

HTTP Client

FTP Daemon

Network Management

The CSS supports the following network management protocols:

SNMP v1

SNMP v2

DC Power Supply Safety Warnings


Warning The DC power supply must be installed in restricted access areas only (for example, dedicated equipment rooms, equipment closets) in accordance with articles 110-16, 110-17, and 110-18 of the national electric code, ANSI/NFPA 70. Connect a DC CSS 11150 or CSS 11800 to a -48 VDC source that is electrically isolated from the AC power source and is reliably grounded to earth.


This equipment is designed to permit the connection of the grounded conductor of the DC supply circuit to the grounding conductor at the equipment. If this connection is made, all of the following conditions must be met:

This equipment shall be connected directly to the DC supply system grounding electrode conductor or bonding jumper from a grounding terminal bar or bus to which the DC supply system grounding electrode conductor is connected.

This equipment shall be located in the same immediate area as any other equipment that has a connection between the grounded conductor of the same DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be grounded elsewhere.

The DC supply source is to be located within the same premises as the equipment.

There shall be no switching or disconnecting devices in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor.


Warning A readily accessible disconnect device must be provided in the fixed wiring for a DC power supply. It must be suitable for the rated voltage and current specified.


Lithium Battery Disposal Warnings

The SCM contains a small lithium battery. Some jurisdictions restrict the ways in which items containing lithium batteries may be disposed. In particular, lithium batteries or products containing lithium batteries may never be disposed of in an unregulated fire. Other restrictions might apply.

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

Waarschuwing

Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.

Varoitus

Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.

Attention

La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.

Warnung

Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.

Avvertenza

L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia.

Advarsel

Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.

Aviso

A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.

¡Advertencia!

El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales.

Varning!

Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.