Cisco PGW 2200 Softswitch Release 9 MML Command Reference
Chapter 6 - Properties
Downloads: This chapterpdf (PDF - 1.07MB) The complete bookPDF (PDF - 8.56MB) | Feedback

Properties

Table Of Contents

Properties

Property Components

Linkset Properties

SS7 Signaling Service Properties

Trunk Group Properties

Property List

Property Definitions

ISUP Timers

Protocol Variants


Properties


Revised: Aug 30, 2011, OL-1116-24

Properties are configurable entities within the Cisco PGW 2200 Softswitch system. These entities can be equipment, circuits, protocols, or software.

Properties take the following syntax:

PropertyName = PropertyValue
 
   

PropertyName can be designated either by *.propertyName or by protocolFamily.propertyName, for example:

*.BInternationalPrefix
 
   
SS7-ANSI.mtp3tstSltmT2
 
   

This chapter describes these property names and their associated values in the following sections:

Property Components

Property List

ISUP Timers

Protocol Variants

Property Components

There are several components that have large numbers of associated properties. In each of these cases, the set of associated properties is provisioned as a property component:

Linkset Properties

SS7 Signaling Service Properties

Trunk Group Properties

Linkset Properties

The linkset property component type (LINKSETPROP) represents the configuration parameters that you can use to tune linkset communications. These properties apply to all linksets you create. You do not have to enter these values.

The linkset properties are listed below. For the list of components applicable to each of these properties and descriptions of these properties, see Table 6-1.

DialogRange, layerretries, layertimer, mtp3ApcMtpRstrtT21, mtp3ApcMtpRstrtT28, mtp3ClearTfc, mtp3DlnkConnAckT7, mtp3FrcUnhT13, mtp3InhAckT14, mtp3LocInhTstT20, mtp3LocInhTstT22, mtp3MaxSltTries, mtp3MsgPriority, mtp3MtpRstrtT20, mtp3MtpRstrtT24, mtp3RepeatRstrtT26, mtp3T12, mtp3T13, mtp3T14, mtp3T20, mtp3T21, mtp3T22, mtp3T7, mtp3Tc, mtp3TfrUsed, mtp3TraSntT29, mtp3tstSltmT1, mtp3tstSltmT2, mtp3tstsrtat10, mtp3UnhAckT12, reference, rudpNumRetx, rudpRetxTimer, rudpWindowSz, SendAfterRestart, slsTimer, sltmT1, sltmT2, Srtat10.

SS7 Signaling Service Properties

The SS7 signaling service properties component types (SIGSVCPROP) serve as configuration parameters that you can use to tune signaling service communications. These properties apply to all SS7 signaling services you create. You do not have to enter these values.

The SS7 signaling service properties are listed below. For the list of components applicable to each of these properties and descriptions of these properties, see Table 6-1.

ACCRespCatName, ACCRespCntlInhibit, ACLDur, ADigitCCPrefix, ADigitCCrm, adjDestinations, AInternationalPrefix, AlarmCarrier, allowCRMCRA, allowEXM, AllowH323Hairpin, ANationalPrefix, Anumnormalise, AOCDMinPeriodicTimerDuration, AOCEnabled, AOCNodeID, atpInclude, AuditWhenSscIs, BcInitState, BDigitCCPrefix, BDigitCCrm, BInternationalPrefix, BNationalPrefix, BothwayWorking, CallForwardRerouteDisabled, CallHoldInterworkingEnabled, CarrierInfoTransferBackward, CarrierInfoTransferForward, carrierSelectInclude, CCOrigin, CctGrpCarrier, CGBA2, CGBA2, cgpnForceIncomplete, cgpnInclude, cgpnPres, CgpnPresRes, ChargeAreaInformation, ChargeOrigin, chnNonGeo, chnOlipInclude, cipInclude, cipNonGeo, CircHopCount, CLIDefaultAllowed, CLISelect, CliSelectionForCodeOfPractice3, CNAPService, COLDefaultAllowed, CompressionType, congProc, ContactListOrder, CorrelationCallIDFormat, CotInTone, CotOnTerminatingSupport, CotOutTone, CotPercentage, CustomerVPNid, CustomerVPNOffNetTblNum, CustomerVPNOnNetTblNum, defaultBC, DefaultCARIDNatNetIdPlan, DefaultCARIDNetId, DefaultCARIDNetType, DefaultCHG, DefaultCHGNOA, DefaultCHGNPI, DefaultDN, DefaultDNNOA, DefaultDNNPI, DefaultDNPres, DefaultDNSI, DefaultOLI, DefaultTmr, delayTimer, DeselOutCicCDRGenerate, DisableQSIGReleaseMethod, DpnssRORoutingNumberLength, EchoCanRequired, EnableCCBSpathReservation, ExpiryWarnToneDur, ExpiryWarnToneType, ExtCOT, DefaultFCINatInd, FastConnect, FAXsupport, FeatureTransparencyDisabled, ForwardCLIinIAM, ForwardSegmentedNEED, FT_IncomingPFXdigitsInsert, FT_IncomingPFXdigitsRemove, FT_OutgoingPFXdigitsInsert, FT_OutgoingPFXdigitsRemove, gapInclude, GatewayAnnouncementPackageSupport, GatewayName, GenerateRedirectionNumber, GenericPurposeString, GLARE, gnInclude, GRA2, GRSEnabled, GRSonSSCEnabled, GtdCapTypeProp, GtdMsgFmt, GWDefaultAudioCodecString, GWNetworkContinuity, GWProtocolVersion, h248BulkAudit, h248CongestionEnable, h248ControlInterval, h248DomainNameRemote, H248GatewayReserveValue, h248GWStdbyHeartbeatInterval, h248inactivitytimer, h248InitFill, h248initialrtt, h248InitLeakAmount, h248LeakInterval, h248LocalIpInterfacePollCount, h248longtimer, h248MaxFill, h248maxretries, h248mgcexectimer, h248mgcpendlimit, h248mgcprovresptimer, h248mgexectimer, h248mgpendlimit, h248OverloadEnable, h248profilename, h248profileversion, h248RemoteIpPollCount, h248SplashAmount, h248TargetolRate, h248TermPendPeriod, h248TimerT1, h248txnpendrespcount, H323AdjunctLink, H323Destination, HandlePresUnavail, hopOn, InbandInfoAvailable, InhibitIncomingCallingNameDisplay, InhibitIncomingConnectedNameDisplay, InhibitIncomingConnectedNumberDisplay, InhibitOutgoingCallingNameDisplay, InhibitOutgoingConnectedNameDisplay, InhibitOutgoingConnectedNumberDisplay, InhibitSipFromMapping, InitEndpointsAsEnabled, IPInScreening, IPTermNumGroups, IPTermNumInterfaces, IPTermNumTerms, IsupToSipRatio, IsupTransEarlyACMEnable, IsupTransEarlyBackwardDisabled, IsupTransparencyDisabled, jipDefault, jipInclude, lapdDropErr, lapdKval, lapdN200, lapdN201, lapdT200, lapdT203, LocalAnnBehavior, LocationNumber, LoopAvoidanceCounter, LoopAvoidanceSupport, MapCLItoSipHeader, MapRNMethod, MaxCBRequest, maxMessageLength, MgcpBehavior, mgcpBulkAudit, mgcpDomainNameLocal, mgcpDomainNameRemote, mgcpGWRspAckTimeout, mgcpGWStdbyHeartbeatInterval, mgcpHeartbeatInterval, mgcpLocalIpInterfacePollCount, mgcpMaxRspAckToBuffer, mgcpRemoteIpPollCount, mgcpRetxCount, mgcpRetxTimer, mgcpRsvpErrHandling, mgcpRsvpPackage, MidCallServiceCustID, mtp3Queue, MWIInvokeTimerT1, MwiStringOFF, MwiStringON, NATTraversalMethod, NatureOfAddrHandling, NewDiversionHdrRequired, NFASImplicitInterfaceId, Normalization, notificationInclude, ocnInclude, OD32DigitSupport, OmaxDigits, OminDigits, OmitCgPnFromUnavailable, Ooverlap, OverlapDigitTime, OwnClli, OwnRoutingNumber, PostConnectToneDuration, PostConnectToneValue, PropagateSvcMsgBlock, ProtocolidandVariantidProv, QSIGTunnelVariant, QsigVariant, radiuskey, radiusretrycount, radiustimeout, redirCapInclude, redirCounterInclude, RedirectingNbrMap, RedirectingNbrSupport, redirInfoInclude, RedirMax, RedirNumForAnalysis, ReleaseMode, respectSipUriUserParm, restartTimer, rnInclude, RORequestDelayTimer, RouteId, RoutePref, SdpXmitToH323Trigger, SendAddressInCgpn, SendDtmfBeforeConnect, serviceCodeInclude, sgcpRetxCount, sgcpRetxTimer, SipCallHoldMethod, SipDtmfContentType, SipRedirAnalysisMethod, SipReferForSingleStepXfer, SipSatelliteIndEnable, SipToIsupRatio, spanId, srcpAuditGwInterval, srcpAuditLineInterval, srcpHeartbeatInterval, srcpIpPortLocal, srcpIpPortRemote, srcpRemoteAuditGwInterval, srcpRetxCount, srcpRetxTimer, sRtpSupported, srtTimer, SSCTInvokeTimerT1, STdigitforCDPN, STdigitforCLI, SuppressCHGNtoCGPNMapping, SuppressCLIDigits, SwitchID, T309Time, T310Time, Ta1TimePeriod, Ta2TimePeriod, Ta3TimePeriod, TbufferDigitLength, TCAPOverIPKpAlive, TCAPOverIPKpOpcod, TCAPOverIPKpTimer, TCAPOverIPTcpConn, TimeOutCBNU, TimeOutCBWF, TlinkAlignTime, TmaxDigits, TminDigits, Toverlap, TransferAwaitConnect, transReqInclude, unavailProc, UUIEProtocolDiscriminator, variant, VOIPPrefix, XmitCallingName.

Trunk Group Properties

The trunk group property component (TRNKGRPPROP) includes the following properties:

accrespcatname, accrespcntlinhibit, acldur, adigitccprefix, adigitccrm, ainternationalprefix, anationalprefix, anumnormalise, aocdefaulttariffid, aocenabled, aocinvoketype, atmconnectiontype, bdigitccprefix, bdigitccrm, binternationalprefix, bnationalprefix, bnumnormalise, btechprefix, callforwardreroutedisabled, carrierscreening, ccorigin, cgpnpresres, chargeorigin, cliselect, cliselectionforcodeofpractice3, clli, compressiontype, cotpercentage, custgrpid, customervpnid, customervpnoffnettblnum, customervpnonnettblnum, defaultcaridnatnetidplan, defaultcaridnetid, defaultcaridnettype, defaultchg, defaultchgnoa, defaultchgnpi, defaultdn, defaultdnnoa, defaultdnnpi, defaultdnpres, defaultdnsi, defaultoli, defaultpn, defaultpnnoa, defaultpnnpi, defaultpnpres, detectfaxmodemtone, dpnssroroutingnumberlength, dtmfcap, echocanrequired, enableccbspathreservation, expirywarntonedur, expirywarntonetype, extcot, faxsupport, featuretransparencydisabled, gatewayrbtonesupport, glare, gtdcaptypeprop, gtdmsgfmt, gwdefaultatmprofile, gwdefaultaudiocodecstring, h248gatewayreservevalue, inhibitincomingcallingnamedisplay, inhibitincomingconnectednamedisplay, inhibitincomingconnectednumberdisplay, inhibitoutgoingcallingnamedisplay, inhibitoutgoingconnectednamedisplay, inhibitoutgoingconnectednumberdisplay, isuptransearlybackwarddisabled, isuptransparencydisabled, loopavoidancecounter, loopavoidancesupport, lrndigitccprefix, lrndigitccrm, maxacl, midcallcpinterval, midcallservicecustid, mwistringoff, mwistringon, networktype, npa, od32digitsupport, omaxdigits, omindigits, ooverlap, origcarrierid, overlapdigittime, ownroutingnumber, packagetype, playannouncement, populatesdpinfoincdr, propagatedelaycounter, referredirectingind, referredirectingnoa, ringnoanswer, satelliteind, screenfailaction, sdpxmittoh323trigger, sendaddressincgpn, srtpallowed, ta1timeperiod, ta2timeperiod, ta3timeperiod, tmaxdigits, tmindigits, toverlap, trunkgrouptaglabel, waitanswertimer, waitorigsdptimer, waittermsdptimer, xmitcallingname.

Property List

Table 6-1 lists the configurable Cisco PGW 2200 Softswitch Release 9 properties and their definitions according to their associated component. In this table, associated components include signaling path, protocol family, trunk group, linkset, session, and profile.


Note The Release 9.8 feature SIP Profiles replaces all existing SIP and EISUP trunk group properties with equivalent SIP and EISUP profile properties. To configure the listed SIP and EISUP properties, use a SIP or EISUP profile (prov-add:profile). For more information about SIP and EISUP profiles, see Cisco PGW 2200 Softswitch Release 9.8 Provisioning Guide.


Property Definitions

Table 6-1 contains an alphabetical listing of the Cisco PGW 2200 Softswitch properties and their definitions.

Properties with the Protocol Family Prefix

In a provisioning session, those properties with the protocolFamily prefix may be overridden by a link set component. The overridden property is then written to properties.dat as LinkSetMMLName.propertyName.

Properties Prefixed by an Asterisk (*)

Those default properties prefixed by an "*" may be overridden by a signal path (or Service) component that is defined in sigPath.dat. The overridden property will be written to properties.dat as mmlcomponentname.propertyname.

Table 6-1 Property Definitions 

Property
Definition
Associated Components for Release 9 through 9.7
Associated Components for Release 9.8

*.AccNetInfo

Indicates the access information of the P-Access-Network-Info header. This property can be provisioned on a trunk group, in a SIP or EISUP profile, or a domain profile.

Valid values: string (1 to 63 characters) or none.

Default value: none.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AccNetInfoType

Indicates the access type of the P-Access-Network-Info header. This property can be provisioned on a trunk group, in a SIP or EISUP profile, or a domain profile.

Valid values: string (1 to 63 characters) or none.

Default value: none.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ACCRespCat
Name

Specifies the ACC Response Controls listed in the ACC Response Category table.

SS7-ANSI

SS7-ITU

TRUNKGROUP

SS7-ANSI

SS7-ITU

TRUNKGROUP

COMMONPROFILE

*.ACCRespCntl
Inhibit

Turns on or off Automatic Congestion Control control procedures based on the Automatic Congestion Level value received by the Cisco PGW 2200 Softswitch from a linked switch. Values: 0 (off) or 1 (on).

Default: 0

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.ACLDur

Specifies the duration in seconds that the Automatic Congestion Level is in effect when the Cisco PGW 2200 Softswitch receives an ACL indication from a linked switch.
Values are integers greater than zero.

Default: 5

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

*.ADigitCCPrefix

Controls functionality that applies a country code prefix to the calling party number before sending the call forward.
Values are 0 (disabled) or 1 (enabled).

Default: 0

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ADigitCCrm

Provides a country code digit string to which leading digits of CgPN, GN_ACgPN, RDN, OCN and PN can be compared. If the digits match, those digits are removed from the front of that number. The NOA codes of that number is set to National. This modification is made before the call is sent forward. Values are NULL (default) or null, or a maximum 5-digit string.

Valid values: 1 through 99999.

Default: NULL

This property is added in software Release 9.6(1).

Note The country code digits won't be stripped if the presentation number doesn't have a + sign to indicate international call.

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.adjDestinations

Number of adjacent destination point codes. Value range: 1 through 256.

Default: 16

SS7-ANSI

SS7-ANSI

*.AInternational
Prefix

Determines the prefix of the outgoing calling number when NOA = International. Value range: NULL or a numeric string.

Default: NULL

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AlarmCarrier

Indicates the method of alarm carrier so that circuit validation tests may be fully compliant with ANSI T1.113. Values are:

0 = unknown (default)
1 = software carrier
2 = hardware carrier

SS7-ANSI

SS7-ANSI

COMMONPROFILE

*.allowCRMCRA

Indicates whether or not to allow the use of the Circuit Reservation Message (CRM) and Circuit Reservation Acknowledgement message (CRA). Values: 0 (for no) or 1 (for yes).

Default: 1

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.AllowEXM

Indicates whether or not to allow the use of the Exit Message (EXM). Values: 0 (for no) or 1 (for yes).

Default: 1

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.AllowH323Hair
pin

Allow H.323 hairpinning. Allows the Cisco PGW 2200 Softswitch to interconnect H.323-originated and H.323-terminated calls by the HSI component. Values: 0 (not allowed) or 1 (allowed).

Default: 0

EISUP

TRUNKGROUP

EISUP

EISUPPROFILE

COMMONPROFILE

*.ANationalPrefix

Determines the prefix of the outgoing calling number when NOA = National. Value range: NULL or a numeric string.

Default: NULL

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AnchorMedia

Defines the media anchor policy on this IP trunk group.

Valid values:

1—Never anchor media on the IP trunk group.

2—Optional. The policy function determines whether to anchor media on the IP trunk group.

3—Always anchor media on the IP trunk group.

Default: 1

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AnchorPolicy

Defines the media anchor policy in the policy function. Determines whether to enable a gateway pool on an IP trunk group. The anchor policy applies only to an egress IP trunk group.

Valid values:

0—Do not enable the SPDM to change gateway pool usage. In response to a service check failure, the SPDM does not enable use of the gateway pool even if the AnchorMedia property is set to Optional on this trunk group. Consequently, the Cisco PGW 2200 Softswitch tries the next trunk group.

1—The SPDM enables use of the gateway pool on an IP trunk if the AnchorMedia property is set to Optional. If the enabled gateway pool satisfies the service requirement, the SPDM enables the Cisco PGW 2200 Softswitch to use the gateway pool.

Default: 0

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Announcement
Option

Specifies whether playing an announcement to the originating side is mandatory. This applies only to an ingress IP trunk group.

0—Playing an announcement is optional.

1—Playing an announcement is mandatory.

Default: 0

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Anumnormalise

Anumnormalise indicates that A-number (CgPn) normalization is appropriate based on the NOA value and the leading digits of the A-number. Leading digits 0 or 00 are the only accepted digits. Valid values: 0 (disabled) or 1 (enabled),

Default: 0

This property is added in software Release 9.4(1) and is a European feature only.

TRUNKGROUP

SS7-ITU

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AOCDefault
TariffId

Allows configuration of the default tariff ID to be applied when AOCInvokeType is configured for all calls (that is, AOCInvokeType = 2). Value range: 1 (default) through 9999.

Default: 1

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AOCEnabled

Determines if Advice of Charge handling would be applied to a call.
Values:

0 = AOC is not enabled
1 = AOC is enabled

Default: 0 (not enabled).

SS7-ITU

TRUNKGROUP

SS7-ITU

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AOCInvokeType

Allows configuration of whether or not the AOC Supplementary services are applicable on a per call basis or for all calls. Values: 1 (on a per call basis the default) or 2 (for all calls).

Default: 1

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.AOCNodeID

This property is included in the Advice of Charge message to identify the node in the network that is activating the AOC service to this call. The subfiles (x/y/z) are limited to the range 0 to 214-1

Values: 0 to 16383 - 0 to 16383 - 0 to 16383

Default: 0 to 0 to 0

SS7-ITU

SS7-UK

SS7-ITU

SS7-UK

COMMONPROFILE

*.AtmConnection
Type

Controls the value of the connection type parameter (ct:) in the local connection options. AtmConnectionType affects originating and terminating ATM call legs.

Note ATM profile negotiation can work over Extended ISUP (EISUP) too.

Valid values:

1 (AAL1)

2 (AAL1_SDT)

3 (AAL1_UDT)

4 (AAL2)

5 (AAL 3/4)

6 (AAL5)

Default value: 4 (AAL2)

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.atpInclude

Indicates whether or not to include the Access Transport Parameter in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

COMMONPROFILE

GRPROFILE

*.AuditWhenSscIs

Specifies if the Cisco PGW 2200 Softswitch (the engine) will perform an audit on the endpoints of the gateway associated with this cxnSigPath when the Cisco PGW 2200 Softswitch receives an In Service (IS) Service State Change (SSC) message. When the value = True, the audit is performed automatically to update the endpoint when the connection is available, which may introduce too much traffic for large gateways (MGX8260, VISM) and cause a performance impact. When the value = False, the endpoint is brought up in service until a manual audit is performed or after a call is received before the actual endpoint state is determined. Values are: True (1) or False (0).

Default: False

MGCP

ISDNPRI (BRI)

MGCP

*.BcInitState

The initial status the Cisco PGW 2200 Softswitch places its nailed up bearer channels following application restart. The MGW can override this status with GSM messages. Values are: IS (in service) or OOS (out of service).

Default: IS

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.BDigitCCPrefix

Controls functionality that applies a country code prefix to the called party number before sending the call forward.
Values are: 0 (disabled) or 1 (enabled).

Default: 0

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.BDigitCCrm

Provides a country code digit string to which the called party number leading digits can be compared, and if matched have those digits removed from the front of the number. This modification is made before sending the call forward. Values are: NULL (default) or null, or a maximum 5-digit string.

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.BInternational
Prefix

Determines the prefix of the outgoing called number when NOA = International. Value range: NULL or a numeric string.

Default: NULL

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.BNationalPrefix

Determines the prefix of the outgoing called number when NOA = National. Value range: NULL or a numeric string.

Default: NULL

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Bnumnormalise

Indicates that B-number (CdPn) normalization is appropriate based on the NOA value and the leading digits of the B-number. Leading digits 0 or 00 are the only accepted digits. Valid values: 0 (disabled) or 1 (enabled).

Default: 0

This property is added in software Release 9.4(1) and is a European feature only.

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Bothway
Working

Specifies if bothway release / circuit-free handling for BTNUP protocol is enabled. Set to 0 to disable. Values: 0 or 1.

Default: 1

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.BTechPrefix

Provides a digit string to be used as a Tech Prefix to the B-number when sending the call forward. Valid values: any integer.string from one digit (minimum) through 16 (maximum) digits. The Tech Prefix uses overdecadic digits B and C and maps them to * and # respectively. The Tech Prefix and a separator are appended to the beginning of the B-number.

This property is added in software Release 9.5(2)

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.CallForward
RerouteDisabled

Disables Call Forwarding rerouting for all calls on the Cisco PGW 2200 Softswitch. Valid values: 0 (reroute enabled) or 1 (reroute disabled).

Default: 0

This property is added in software Release 9.4(1).

DPNSS

EISUP

ISDNPRI

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

*.CallHoldInter
workingEnabled

Indicates whether Cisco PGW 2200 Softswitch interworks call hold and TP between SIP/H.323, EISUP, and ISUP. When this property is configured as disabled, Cisco PGW 2200 Softswitch drops HOLD and TP indications coming from the ISUP side. If the property is configured enabled, Cisco PGW 2200 Softswitch maps the ISUP side HOLD and TP to SIP Re-Invite.

Valid values:

0—TDM to IP hold interworking disabled (but IP to TDM hold interworking enabled)

1—Bidirection hold interworking enabled

2—IP to TDM hold interworking disabled (but TDM to IP hold interworking enabled)

3—Bidirection hold interworking disabled

Default Value: 1

Dynamically Reconfigurable: yes

EISUP

SIP

EISUP

SIP

*.CallTagList

Indicates the tag list for a specified trunk group. You define the CallTagList property by issuing an MML command. The property is saved in a TimesTen database table.

Value: String (32 alpha/numeric characters)

Default: NULL

This property is added in software Release 9.8(1).

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.CarrierInfo
TransferBackward

Japan ISUP; mandatory in ACM and ANM. If it is not present, it is generated using the default value. Value range: As many as 25 characters.

Default: 00FC05FE03000231

SS7-Japan

SS7-Japan

*.CarrierInfo
TransferForward

Japan ISUP; mandatory in IAM. If it is not present, it is generated using the default value. Value range: As many as 25 characters.

Default: 00FB05FE03000231

SS7-Japan

SS7-Japan

*.CarrierScreening

Determines if carrier screening and selection is to be applied on this call (using the carrier translation table).
Values:

0 = Do not apply
1 = Apply carrier selection

Default: 0

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.carrierSelect
Include

Indicates whether or not to include the carrier selection information parameter in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.CCOrigin

Provides against the origin trunk group of a call the country code digits, which if needed can be prefixed on a number before sending the call forward. Only required when the property domain is SigPath or LinkSet. Values: NULL or a maximum 5-digit string.

Default: NULL

DPNSS

ISDNPRI

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

H248

ISDNPRI (BRI)

MGCP

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.CctGrpCarrier

Indicates the method of circuit group carrier so that circuit validation tests may be fully compliant with ANSI T1.113. Values are:

0 = unknown
1 = analog
2 = digital (default)
3 = digital & analog

SS7-ANSI

SS7-ANSI

COMMONPROFILE

*.CGBA2

Determines if group (0) or Individual (1) circuit group blocking acknowledgments (CGBAs) are required before the blocking is considered successful. Only applicable to ANSI SS7, IBN7, and CTUP protocols. Values: 0 or 1. (Only available in software Release 9.3(2) and later.)

Note When set to 1, a significant performance impact occurs for individual circuit supervision messages during maintenance or during a failure condition.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.cgpnForce
Incomplete

Provides a configurable option to set the Calling Party Number Incomplete Indicator field within IAM to Incomplete for all calls. A new sigPath property (*.cgpnForceIncomplete) has been created to enable this functionality. This property is read by the protocol when packing the Calling Party Number parameter in an outgoing message. If the property is set, then the protocol overrides the Call Context value so that the Incomplete Indicator is Incomplete (1).

Valid values are: 0 (default) (disable function and allow the protocol to set its value normally) and 1 (incomplete).

This newly patched property is only available in properties.dat in the /opt/CiscoMGC/etc/CONFIG_LIB/new directory.

EISUP

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

EISUP

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.cgpnInclude

Indicates whether or not to include the CGPN in the IAM on the originating trunk group. Values: 0 (no) or 1 (yes).

Default: 1

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.CgpnPres

Determines if the incoming called number presentation indication is to be overridden. Values: 0 (False) for leave as-is or 1 (True) for set to presentation restricted.

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.CgpnPresRes

Calling party number restricted. Determines if the incoming called number presentation indication is to be overridden. Value range: 0 (False) (default) for leave as-is, or 1 (True) for set to presentation restricted.

SS7-ANSI

SS7-ITU

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-ITU

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.ChargeArea
Information

This property is mandatory for Japan ISUP and it has to be changed for different areas. It allows changing charge area information for different locations. Value range: As many as 25 characters.

Default: 010203

SS7-Japan

SS7-Japan

*.ChargeOrigin

Specifies the charge origin. The craftperson decides what value of charge origin is to be used. Value range: 0 to 9999

Default: 0

SS7-ITU

TRUNKGROUP

SS7-ITU

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

CheckANumDataNOA

checks for A Number nature of address and modify National Indicator Flag

.Default value is 0 and possible values are 0 and 1.

CheckANumDataNOA ( 0=disable, 1= enable)

This property is used to modify National indicator flag only when the incoming message is a SIPI invite(SIP - ISUP embedded message)

 

mdl-SIP

*.checkClear
ChannelCodecIn
SDP

Use this property to control whether the Cisco PGW 2200 Softswitch checks the clear channel codec in the SDP of the first incoming SIP INVITE message to conclude that a call is a data call. This property is provisioned in SIP profiles. Valid values: boolean.

0 = no clear channel codec check in the SDP.

1 = performs the clear channel codec check in the SDP.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.CheckSipTgrp
Param

Use this property to control whether the Cisco PGW 2200 Softswitch checks the tgrp parameter in the request line of the first incoming SIP INVITE message to conclude that a call is a data call. This property is provisioned in SIP profiles.

Valid values: boolean.

0 = does not check the tgrp parameter in the request line.

1 = checks the tgrp parameter in the request line.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.chnNonGeo

Indicates whether or not to include the Charge Number in an IAM on all calls to non-geographic numbers. The geographic nature of a number is determined by the Address Class analysis result value. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.chnOlipInclude

Indicates whether or not to include Charge Number and Originating Line Info as a pair in the IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.cipInclude

Indicates whether or not to include the Carrier Identification Parameter (CIP) in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.cipNonGeo

Indicates whether or not to include the CIP in an IAM on all calls to non-geographic numbers. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.CircHopCount

Set a maximum value for the number of hops before a call must be completed.

Valid values: 0-31

Note When set to 0, the property is disabled.

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

SS7-ITU

SS7-UK

COMMONPROFILE

*.CLIDefault
Allowed

If set to TRUE then it adjusts the presentation restricted field in the CLI to Presentation Allowed; if FALSE then it takes the mapped value from the OCC or TCC protocol side or the default value from the Map for this field if there is no received value from the other protocol side. Values: TRUE or FALSE

Default: FALSE

SS7-ANSI

SS7-ITU

SS7-Japan

SS7-UK

SS7-ANSI

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.ClcIsdnPack

Determines whether the CLC_ISDN should be passed when originating side is SIP. This property should be set on the terminating side. Valid values:

0—Do not pass CLC_ISDN.

1—If originating protocol is SIP, pack CLC_ISDN(3) in the outgoing message.

Default value: 0.

This property is added in software Release 9.7(3) S32P32.

SIP

*.ClcTransparency

Determines whether the Cisco PGW 2200 Softswitch transits CLC_ISDN or CLC_PSTN transparently when both originating and terminating side are DPNSS. The property should be set on the terminating side. Valid values:

0—PGW does not transit CLC_ISDN or CLC_PSTN

1—PGW transits CLC_ISDN or CLC_PSTN transparently

Default: 0

This property is added in software Release 9.7(3) S30P30.

DPNSS

*.CLIPEss

Sets the Calling Line Identity Presentation Essential operation. 0—Do not request CLI., 1—Request CLI if not already provided and drop the call if CLI is not provided, or 2—Request CLI if not already provided and continue with the call even if CLI is not provided.

Value range: 0, 1, or 2.

Default: 0

DPNSS

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.CLISelect

This is used to determine the presentation number. Values: CLI or GENERICNUM.

Default: CLI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.CliSelectionFor
CodeOfPractice3

Provision the level of calling line identity (CLI) that you want the PGW 2200 to use when sending the calling line identities (such as Calling Party Number or Generic Number parameter) to the next exchange. Valid values for this property are in the range 0-2 (Default 0).

Valid values for the property CliSelectionForCodeOfPractice3:

0—Indicates no specific CLI selection (default)

1—Indicates single CLI selection. Sends only the CLI.

2—Indicates dual CLI selection. Sends the CLI; or the PGW 2200 send the CLI and the PN.

3—Indicates CBI bit transparency over DSS1.

Set the property CliSelectionForCodeOfPractice3 to 0 or 2 to meet your service-provider requirements.

TRUNKGROUP

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.CLLI

Specifies the common language location identifier (CLLI).

Default: NULL

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.CNAPService

Indicates whether name mapping between ISUP and NAS is enabled.

Values:

0 = CNAP Service is disabled.

1 = CNAP Service is enabled.

Default: 0

SS7-ANSI

SSI-ITU

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

*.COLDefault
Allowed

If set to TRUE then it adjusts the presentation restricted field in the connected line Id to Presentation Allowed; if FALSE then it takes the mapped value from the OCC or TCC protocol side or the default value from the Map for this field if there is no received value from the other protocol side. Values: TRUE or FALSE

Default: FALSE

SSI-ITU

SS7-Japan

SS7-UK

SSI-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.commonprofile

Contains a pointer to a Common Profile.

Valid values: String. Enter the name of an existing Common Profile.

Default value: NULL

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

*.Compression
Type

Compression type. Indicates the G.711 compression type used on the trunk. Values are: 0 (none), 1 (mu-law), 2 (A-law), or 3 (clear channel).

Default: 1

DPNSS

ISDNPRI

MGCP

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.confusion

A flag indicating whether or not to send the Confusion message when an unrecognized message type is received. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.congProc

Indicates the procedure to follow when there is congestion on ISUP circuits. This value is taken from the originating trunk group and used when reattempting occurs. Values: ALTRTE (alternate routing) or BLO (blocking).

Default: ALTRTE

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.ContactListOrder

Defines the order in which the target list is appended, once new Contact headers are received in a 300, 301, or 302 response message. Values are 1 (default)-At the beginning of the list, 2-At the end of the list, or 3-Replace the list with the new list. Valid values: 1 through 3.

Default value:1

SIP

SIP

*.CorrelationCall
IDFormat

Indicates the type of correlation identifier sent in the call establishment message. Values: 0 (H.323) or 1 (SIP).

Default: 0

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.CotInTone

Receive tone for continuity test (COT) hardware. The tone to listen for when doing a COT. Enter value in Hz. Values: 1780 or 2010.

Default: 2010

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

*.CotOn
Terminating
Support

Determines if the terminating side does not fully support COT. If the terminating side does not support COT, the Cisco PGW 2200 Softswitch waits for the COT result from the originating switch and then forwards the IAM to the terminating side. Values: 0 (COT special handling is required) or 1 (COT is fully supported on the terminating side).

Default: 1

SSI-ITU

SSI-ITU

*.CotOutTone

Transmit tone for COT hardware. The tone that is produced. Enter value in Hz. Values: 1780 or 2010.

Default: 2010

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

*.CotPercentage

Statistical COT. Value range: 0 through 100%.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SSI-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.CustGrpId

ID of customer associated with a particular trunk group (previously called VNET ID). Maps to trunk group property CustGrpId. Values are any alphanumeric with length of 4, or 0 if not defined.

Default: 0000

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.CustomerVPNid

Assigns a VPN ID to a trunk group or system. Valid values: 1 through 8 alphanumeric character string.

Default: 00000000

This property is added in software Release 9.4(1).

DPNSS

EISUP

ISDNPRI

QSIG

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

*.CustomerVPN
OffNetTblNum

Allows assignment of a VPN off-net profile table index to a particular trunk group. Value range: 1 through 8

1 (Indicates that completely transparent operation is required or the call will not complete.)
2 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
3 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
4 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
5 (Sets to indicate that the attempted feature will be removed from the onward routed call, and the indicator is informed of this.)
6 (Sets to release a feature call.)
7 (Sets to release a feature call.)
8 (Sets to remove the feature string and continue.)

Default: 0

This property is added in software Release 9.4(1). The range changed to 1-8 and the default changed to 5 in software Release 9.6(1)

DPNSS

EISUP

ISDNPRI

QSIG

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

*.CustomerVPN
OnNetTblNum

Allows assignment of a VPN on-net profile table index to a particular trunk group. Value range: 1 through 8

1 (Indicates that completely transparent operation is required or the call will not complete.)
2 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
3 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
4 (Sets to feature transparency preferred by a nontransparent destination can be used if necessary to complete the call.)
5 (Sets to indicate that the attempted feature will be removed from the onward routed call, and the indicator is informed of this.)
6 (Sets to release a feature call.)
7 (Sets to release a feature call.)
8 (Sets to remove the feature string and continue.)

Default: 0

This property is added in software Release 9.4(1). The range changed to 1-8 and the default changed to 5 in software Release 9.6(1)

DPNSS

EISUP

ISDNPRI

QSIG

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

Cutthrough

Possible Values: 0 through 3; (0)

0 = Undefined

1 = Seize - call is through connected a seize, not applicable

2 = ACM - call is through connected at ACM

3 = ANM - call is through connected at ANM

ROUTING TRUNK GROUP

SIP TRUNK GROUP

ROUTING TRUNK GROUP

SIP TRUNK GROUP

*.defaultBC

Default bearer capability. Indicates the coding used by the User Service Information parameter in the outgoing IAM message.

For the SS7-UK protocol family, setting the property to 3_1_KHZ, converts the outgoing ISDN 3.1 kHz (CAT3) call over BTNUP Trunk Group to ISDN speech (CAT2) call.
Values are: SPEECH or 3_1_KHZ.

Default: SPEECH

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.DefaultCARID
NatNetIdPlan

Maps to trunk group property DefaultCARIDNatNetIdPlan (Default Carrier Identifier National Network Identifier Plan). Values are: 0 (NOTUSED),
1 (NATIONAL_NETWORK_ID_NATIONAL CARRIER_ACCESS_CODE),
2 (NATIONAL_NETWORK_ID_PLAN_2_DIGIT),
3 (NATIONAL_NETWORK_ID_PLAN_3_DIGIT), or
4 (NATIONAL_NETWORK_ID_PLAN_4_DIGIT).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCARID
NetId

Maps to trunk group property DefaultCARIDNetId (Default Carrier Identifier Network Identifier). Values are: 2 to 4 digits or NULL.
Default: 00

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCARID
NetType

Maps to trunk group property DefaultCARIDNetType (Default Carrier Identifier Network Type). Values: 0 (NOTUSED),
1 (NETWORK_USER_SPECIFIED),
2 (NETWORK_NATIONAL),
3 (NETWORK_INTERNATIONAL), or
4 (NETWORK_CCITT).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCHG

Maps to trunk group property DefaultCHG (Default Charge Number). Values are: 1 to 16 digits or NULL.

Default: 0

Note For an SS7 trunk group, if you set this property to a value other than the default (0), you must also set the properties *.DefaultCHGNOA and *.DefaultCHGNPI to non-default values.

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

ISDNPRI (BRI)

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCHG
NOA

Maps to trunk group property DefaultCHGNOA (Default Charge Number NOA). Values are: 0 (NOTUSED),
1 (CHNOA_ANI_CGSUB_SUB_NUM),
2 (CHNOA_ANI_NOT_AVAIL),
3 (CHNOA_ANI_CGSUB_NAT_NUM),
4 (CHNOA_ANI_CDSUB_SUB_NUM),
5 (CHNOA_ANI_CDSUB_NO_NUM), or
6 (CHNOA_ANI_CDSUB_NAT_NUM).

Default: 0

Note For an SS7 trunk group, if you set this property to a value other than the default (0), you must also set the properties *.DefaultCHG and *.DefaultCHGNPI to non-default values.

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

ISDNPRI (BRI)

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCHGNPI

Maps to trunk group property DefaultCHGNPI (Default Charge Number NPI). Values are: 0 (NOTUSED),
1 (NPI_NONE),
2 (NPI_E164),
3 (NPI_DATA),
4 (NPI_TELEX),
5 (NPI_PNP),
6 (NPI_NATIONAL),
7 (NPI_TELEPHONY),
8 (NPI_MARITIME_MOBILE),
9 (NPI_LAND_MOBILE), or
10 (NPI_ISDN_MOBILE).

Default: 0

Note For an SS7 trunk group, if you set this property to a value other than the default (0), you must also set the properties *.DefaultCHG and *.DefaultCHGNOA to non-default values.

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

ISDNPRI (BRI)

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultCPC

Add a new trunk group property DefaultCPC. If not NULL and within the specified range (0-20), pass this information on the Egress IAM.Values are:

0 (NOTUSED),
1 (CLASS_LANG_UNKNOWN),
2 (CLASS_LANG_ENGLISH),
3 (CLASS_LANG_RUSSIAN),
4 (CLASS_LANG_FRENCH),
5 (CLASS_LANG_GERMAN),
6 (CLASS_LANG_SPANISH),
7 (CLASS_LANG_ITALIAN),
8(CLASS_LANG_DUTCH),
9(CLASS_LANG_CHINESE),
10 ( CLASS_LANG_JAPANESE),
11 (CLASS_LANG_ARABIC),
12 (CLASS_LANG_GREEK),
13 (CLASS_LANG_PORTUGESE),
14 (CLASS_LANG_NORWEGIAN),
15 (CLASS_LANG_SWEDISH),
16 (CLASS_LANG_HUNGARIAN),
17 (CLASS_LANG_ADMIN1),
18(CLASS_LANG_ADMIN2),
19(CLASS_LANG_ADMIN3), or
20 (CLASS_LANG_MARTIAN)

Default:0

This property is added in software Release 9.8(1).

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultDN

Maps to trunk group property DefaultDN (Default Directory Number). This property is needed on the Trunk Group if it is a switched call and on the SigPath if it is a nailed call. Values are: 1 to 14 digits or NULL.

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultDNNOA

Default Directory Number NOA. Values are
0 (NOTUSED),
1 (NOA_NONE),
2 (NOA_UNKNOWN),
3 (NOA_SUBSCRIBER),
4 (NOA_NATIONAL),
5 (NOA_INTERNATIONAL),
6 (NOA_NETWORK),
7 (NOA_MERIDIAN),
8 (NOA_ABBR),
9 (NOA_UNIQUE_3DIG_NAT_NUM),
10 (NOA_ANI),
11 (NOA_NO_ANI_RECD),
12 (NOA_NON_UNIQUE_SUBSCRIBER),
13 (NOA_NON_UNIQUE_NATIONAL),
14 (NOA_NON_UNIQUE_INTERNATIONAL),
15 (NOA_OPRREQ_TREATED),
16 (NOA_OPRREQ_SUBSCRIBER),
17 (NOA_OPRREQ_NATIONAL),
18 (NOA_OPRREQ_INTERNATIONAL),
19 (NOA_OPRREQ_NO_NUM),
20 (NOA_CARRIER_NO_NUM),
21 (NOA_950_CALL),
22 (NOA_TEST_LINE_CODE),
23 (NOA_INT_INBOUND),
24 (NOA_NAT_OR_INTL_CARRIER_ACC_CODE_INC),
25 (NOA_CELL_GLOBAL_ID_GSM),
26 (NOA_CELL_GLOBAL_ID_NMT_900),
27 (NOA_CELL_GLOBAL_ID_NMT_450),
28 (NOA_CELL_GLOBAL_ID_AUTONET),
29 (NOA_PORTED_NUMBER),
30 (NOA_PISN_SPECIFIC_NUMBER),
31 (NOA_UK_SPECIFIC_ADDRESS),
32 (NOA_SPARE),
33 (NOA_MCI_VNET),
34 (NOA_INTERNATIONAL_OPR_TO_
OPR_OUTSIDE_WZI),
35 (NOA_INTERNATIONAL_OPR_TO_
OPR_INSIDE_WZI),
36 (NOA_DIRECT_TERMINATION_OVERFLOW),
37 (NOA_ISN_EXTENDED_
INTERNATIONAL_TERMINATION),
38 (NOA_TRANSFER_ISN_TO_ISN),
39 (NOA_CREDIT_CARD),
40 (NOA_DEFINED_IN_SSUTR),
41 (NOA_DEFINED_IN_SSUTR2),
42 (RESERVED), or 43 (NOA_DISCARDED). Default: 0.

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultDNNPI

Maps to trunk group property DefaultDNNPI (Default Directory Number NPI). Values are: 0 (NOTUSED),
1 (NPI_NONE),
2 (NPI_E164),
3 (NPI_DATA),
4 (NPI_TELEX),
5 (NPI_PNP),
6 (NPI_NATIONAL),
7 (NPI_TELEPHONY),
8 (NPI_MARITIME_MOBILE),
9 (NPI_LAND_MOBILE), or
10 (NPI_ISDN_MOBILE).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultDNPres

Maps to trunk group property DefaultDNPres (Default Directory Presentation Indicator). Values are: 0 (NOTUSED),
1 (PRES_NO_INDICATION),
2 (PRES_ALLOWED),
3 (PRES_RESTRICT), or
4 (PRES_UNAVAIL).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultDNSI

Maps to trunk group property DefaultDNSI (Default Directory Screening Indicator). Values are: 0 (NOTUSED),
1(SI_NONE),
2 (SI_USER_PROVIDED_NOT_VERIFIED),
3 (SI_USER_PROVIDED_VERIFIED_
PASSED),
4 (SI_USER_PROVIDED_VERIFIED_
FAILED), or
5 (SI_NETWORK_PROVIDED).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultFCINat
Ind

Provisions the FCI A bit (national call indicator) integer. If you do not configure this property, the SIP module uses the default value. Both ISUP and TUP use this property. For the eisup national indicator transparency, the Cisco PGW 2200 Softswitch checks for the existence of a national indicator. If a national indicator exists, the Cisco PGW 2200 Softswitch uses it rather than generate it from the NOA.

Valid Values:

0 = national call

1 = international call

Default: 0 (indicates that the call will be treated as national call)

Dynamically Reconfigurable: yes

SIP

SIP

*.DefaultOLI

Maps to trunk group property DefaultOLI (Default Originating Line Information). Values: 0 (NOTUSED),
1 (OLI_POTS),
2 (OLI_MULTIPARTY_LINE),
3 (OLI_ANI_FAILURE),
4 (OLI_STATION_LEVEL_RATING),
5 (OLI_SPECIAL_OPERATOR_REQ),
6 (OLI_AIOD),
7 (OLI_COIN_DATABASE),
8 (OLI_800_SERVICE_CALL),
9 (OLI_COIN),
10 (OLI_PRISON_INMATE_SERVICE),
11 (OLI_INTERCEPT_BLANK),
12 (OLI_INTERCEPT_TROUBLE),
13 (OLI_INTERCEPT_REGULAR),
14 (OLI_TELCO_OPERATOR_CALL),
15 (OLI_OUTWATS),
16 (OLI_TRS_1),
17 (OLI_TRS_2),
18 (OLI_TRS_3),
19 (OLI_CELLULAR_SVC_1),
20 (OLI_CELLULAR_SVC_2),
21 (OLI_CELLULAR_SVC_ROAMING),
22 (OLI_PRIVATE_PAYSTATIONS),
23 (OLI_ACCESS_FOR_VPN_TYPES_OF_SVC),
24 (OLI_INTERLATA_RESTRICTED),
25 (OLI_TESTCALL),
26 (OLI_TOLLFREE_FROM_PAYSTATIO),
27 (OLI_CUSTOMER_SPECIFIC_1),
28 (OLI_CUSTOMER_SPECIFIC_2),
29 (OLI_INTERLATA_RESTRICTED_HOTEL), or
30 (OLI_INTERLATA_RESTRICTED_COINLESS).

Default: 0

EISUP

SS7-ANSI

TRUNKGROUP

EISUP

SS7-ANSI

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultPN

Enables the incoming trunk group to have a default PN if the incoming call does not have one, overdecadic digits are supported. Valid values: overdecadic digit string from 1 through 20 digits.

Default: NULL

This property is added in software Release 9.4(1).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultPNNOA

Default Presentation Number NOA value. Values are
0 (NOT USED) - default, 1 (NOA_NONE),
2 (NOA_UNKNOWN), 3 (NOA_SUBSCRIBER),
4 (NOA_NATIONAL), 5 (NOA_INTERNATIONAL),
6 (NOA_NETWORK), 7 (NOA_MERIDIAN),
8 (NOA_ABBR), 9 (NOA_UNIQUE_3DIG_NAT_NUM),
10 (NOA_ANI), 11 (NOA_NO_ANI_RECD),
12 (NOA_NON_UNIQUE_SUBSCRIBER),
13 (NOA_NON_UNIQUE_NATIONAL),
14 (NOA_NON_UNIQUE_INTERNATIONAL),
15 (NOA_OPRREQ_TREATED),
16 (NOA_OPRREQ_SUBSCRIBER),
17 (NOA_OPRREQ_NATIONAL),
18 (NOA_OPRREQ_INTERNATIONAL),
19 (NOA_OPRREQ_NO_NUM),
20 (NOA_CARRIER_NO_NUM),
21 (NOA_950_CALL), 22 (NOA_TEST_LINE_CODE),
23 (NOA_INT_INBOUND),
24 (NOA_NAT_OR_INTL_CARRIER_ACC_CODE_INC),
25 (NOA_CELL_GLOBAL_ID_GSM),
26 (NOA_CELL_GLOBAL_ID_NMT_900),
27 (NOA_CELL_GLOBAL_ID_NMT_450),
28 (NOA_CELL_GLOBAL_ID_AUTONET),
29 (NOA_PORTED_NUMBER),
30 (NOA_PISN_SPECIFIC_NUMBER),
31 (NOA_UK_SPECIFIC_ADDRESS), 32 (NOA_SPARE),
33 (NOA_MCI_VNET),
34 (NOA_INTERNATIONAL_OPR_TO_
OPR_OUTSIDE_WZI),
35 (NOA_INTERNATIONAL_OPR_TO_
OPR_INSIDE_WZI),
36 (NOA_DIRECT_TERMINATION_OVERFLOW),
37 (NOA_ISN_EXTENDED_
INTERNATIONAL_TERMINATION),
38 (NOA_TRANSFER_ISN_TO_ISN),
39 (NOA_CREDIT_CARD),
40 (NOA_DEFINED_IN_SSUTR),
41 (NOA_DEFINED_IN_SSUTR2), 42 (RESERVED),
43 (NOA_DISCARDED),
44 (NOA_NETWORK_RN_CONCAT_WITH_CDPN),
45 (NOA_NAT_NUM_WITH_SELECT_OF_CARR),
46 (NOA_INT_NUM_WITH_SELECT_OF_CARR),
47 (NOA_NATIONAL_SPARE_2),
48 (NOA_PORTED_NUMBER_OR_
SCREENED_FOR_PORTING),
49 (NOA_SPECIAL_NUMBER),
50 (NOA_NATL_NUM_TRANSIT_NETWORK_SELECT),

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultPNNOA

51 (NOA_INTL_NUM_TRANSIT_NETWORK_SELECT),
52 (NOA_SPAIN),
53 (NOA_PARTIAL_CALLING_LINE_ID),
54 (NOA_NETWORK_RN_NSN_FORMAT, or
55 (NOA_NETWORK_RN_NETWORK_
SPECIFIC_FORMAT)

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultPNNPI

Displays the default Presentation Number NPI value. Valid values: 0 through 10.

0 (NOTUSED) (default),
1 (NPI_NONE),
2 (NPI_E164),
3 (NPI_DATA),
4 (NPI_TELEX),
5 (NPI_PNP),
6 (NPI_NATIONAL),
7 (NPI_TELEPHONY),
8 (NPI_MARITIME_MOBILE),
9 (NPI_LAND_MOBILE), or
10 (NPI_ISDN_MOBILE)

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultPNPres

Displays the Default Presentation Number Presentation Indicator value.

Valid values: 0 through 4.

0 (NOTUSED) (default),
1 (PRES_NO_INDICATION),
2 (PRES_ALLOWED),
3 (PRES_RESTRICT), or
4 (PRES_UNAVAIL)

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DefaultTmr

This string property provisions the Transmission medium requirement (TMR).

Valid Values:

SPEECH

UNRES_64K

AUDIO_3K

Default: SPEECH

Dynamically Reconfigurable: Yes

SIP

SIP

*.DelayedOfferToEarlyOffer
Interworking

This property applies to SIP calls for the called side only. The property indicates whether or not the Cisco PGW 2200 Softswitch will include SDP in an initial INVITE message if the Cisco PGW 2200 Softswitch does not receive SDP in a message from the calling side. Provision this property on the TCC SIP trunk group.

Valid values:

0—No SDP

1—Dummy SDP is provisioned

Default value: 0

This property is added in software Release 9.8(1).

SIPPROFILE

DOMAINPROFILE

*.delayTimer

Set a delay timer from TIOS to Engine when ISDN sigpath has changed service state so the Engine will not be affected by a "bouncing" link.

This is supported for ISDN Q.931/Q.921/RLM and ISDN Backhaul (Corsair) protocols only.

Default: 30

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.DeselOutCic
CDRGenerate

Controls whether the Cisco PGW 2200 Softswitch generates a Deselect Outgoing Circuit CDR for SIP.

Values:

True = The Cisco PGW 2200 Softswitch adds a Deselect Outgoing Circuit CDR to the cdr.bin file.

False = The Cisco PGW 2200 Softswitch does not add a Deselect Outgoing Circuit CDR to the cdr.bin file.

Default: True

TRUNKGROUP

SIP

*.dialogRange

TCAP transaction ID range (for example, 1 through 10000) for a specific subsystem. A string of 1 to 21 ASCII characters. An entry of zero (0) means the entire range. This property can be provisioned for SS7-ANSI and SS7-ITU.

For example, if you set dailogrange="1" for proto="SS7-ANSI" all the linksets created by this command have dialogrange set to 1.

Command examples:

prov-ed:lnksetprop:name="SS7-ANSI", dialogrange="abc"
prov-add:name="test-lset",proto="SS7-ANSI"

Default: 0

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.DisableQSIG
ReleaseMethod

Indicates the QSIG release method. An H.225 signaling connection can be released with a single Release Complete message instead of a three-stage QSIG release sequence. This is only applicable to release procedures initiated by the Cisco PGW 2200 Softswitch. The Cisco PGW 2200 Softswitch accepts receipt of either type of release method.

Valid Values:

0 —Normal QSIG release is enabled for QSIG tunneling

1 —Normal QSIG release is disabled for QSIG tunneling

Default Value: 0

EISUP

TRUNKGROUP

EISUP

EISUPPROFILE

COMMONPROFILE

*.DpnssRO
RoutingNumber
Length

For DPNSS-QSIG PR ROO interworking, the DPNSS RO routing number and call reference are concatenated and in QSIG they are separate fields. An indication of where the divide point is between the fields is an optional parameter in the DPNSS specification. It is therefore necessary to provide a configurable definition of how to split these two fields.

Valid Values: 2-10

Default Value: 4

DPNSS

TRUNKGROUP

DPNSS

TRUNKGROUP

COMMONPROFILE

*.DtmfCap

Defines the DTMF capability of the egress trunk group.

Valid values:

0—Ignore DTMF capability

1—RFC 2833 DTMF capability

2—Out of band DTMF capability

Default Value: 0

DPNSS

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DummyAudio
CodecString

Specifies the dummy codec list in an H.248 add request when neither remote SDP nor a local codec is provisioned. This property applies only for a DBE. Values are NULL, G.711u, G.711a, G.726-32, G.726-24, G.726-16, G.729, G.729a, G.729b, G.729b-L, G.723.1-H, G.723.1-L, G.723.1a-L, G.GSM-F, G.GSM-H, and G.GSM-eF. You must separate the values in the dummy codec list with separated by semicolons.

Valid values: a string from 1-140 characters

Default dummy codec string: G.711u;G.711a;G.726-32;G.726-24;G.726-16;G.729;G.729a;G.729b;G.729b-L;G.723.1-H;G.723.1-L;G.723.1a-L;G.GSM-F; G.GSM-H;G.GSM-eF

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.DummyVideo
CodecString

Specifies the dummy video codec list in an H.248 add request when neither remote SDP nor a local codec is provisioned. This property applies only for a DBE. Values are: NULL; H.264; H263; H261; H263-1988; JPEG; MPV; CelB; MP2T; nv, separated by semicolons.

Valid values: a string from 1-140 characters

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.EchoCan
Required

Echo Canceller Required. Specifies whether to send a modify-connection message (MDCX) for echo control. Enter a value of 0 or 1 for EchoCanRequired on the trunk group or sigpath.

The Cisco PGW 2200 Softswitch follows the following procedure for an SS7 terminated call after the call is answered. If the Cisco PGW 2200 Softswitch receives a call-in-progress message (CPG) with backward call indicators (BCI) from the SS7 side, it takes the specified action.

If EchoCanRequired=1 on the originating side:

If the echo control device (ECD) indicator = 0 in BCI, send MDCX with e: on

If the ECD = 1 in BCI, send MDCX with e: off

If EchoCanRequired=0 on the originating side (default):

If EchoCanRequired=0 on the terminating side, do not send an MDCX for echo control

If EchoCanRequired=1 on the terminating side,

If ECD = 1 in incoming ACM, do not send e:on in MDCX

If ECD = 0 in incoming ACM, send e:on in MDCX.

EISUP

MGCP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.EnableCCBS
pathReservation

Allows configuration of the Path Reservation option for each QSIG destination. In the case of EISUP, this is valid for HSI destinations only.

Valid Values:

0—CCBS with Path Reservation is disabled

1 —CCBS with Path Reservation is enabled

Default Value: 0

EISUP

QSIG

TRUNKGROUP

EISUP

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.EnableIP
Screening

Enables the incoming trunk group to select a dial plan based on the IP address, source ID, and CLI prefix tables. Valid values: 0 (no dial plan lookup) or 1 (require dial plan lookup).

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ExpiresTimer

Maps to trunk group property ExpiresTimer. The timer value (in milliseconds) used in the Expire header of SIP messages. Value range: any value greater than 0.

Default: 60000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

ExpiryWarnTone
Dur

Expiry warning tone duration, in seconds. Value range: 1 through 5.

Default: 1

SS7-ITU

TRUNKGROUP

SS7-ITU

TRUNKGROUP

COMMONPROFILE

ExpiryWarnTone
Type

String defining the tone to be applied to warn that the assigned call duration is almost expired. Value range: Any valid MGCP event name.

Default: NULL

SS7-ITU

TRUNKGROUP

SS7-ITU

TRUNKGROUP

COMMONPROFILE

*.ExtCOT

Determines the type of COT handling for the specified destination. Values: 0 (no COT), loop, or transponder.

Default: Loop

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.FastConnect

The purpose of this property is to allow/disallow the signal being sent to LCM when a CALL PROCEEDING, a PROGRESS and an ALERTING message is received from the MGW. Values:

0 = Normal behavior, enable all signals to LCM.

1 = Disable signals to LCM when a Call proceeding message is received from the MGW.

2 = Disable signals to LCM when a Call Proceeding or a Progress message are received from the MGW.

3 = Disable signals to LCM when a Call Proceeding or a Progress or an Alerting message is received from the MGW.

Default: 0

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.FAXsupport

Indicates if T.38 FAX calls are supported on the trunk group. This property must be enabled on the incoming and outgoing trunk groups for T.38 fax calls to be successfully routed. Values are: 0 (none) or 1 (T.38 Fax).

Default: 0

DPNSS

EISUP

ISDNPRI

SS7-ANSI

SS7-ITU

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

SS7-ANSI

SS7-ITU

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Feature
Transparency
Disabled

Disables QSIG Feature Transparency for all calls on the Cisco PGW 2200 Softswitch. Valid values: 0 (Feature Transparency enabled) or 1 (Feature Transparency disabled).

Default: 0

This property is added in software Release 9.4(1).

DPNSS

EISUP

ISDNPRI

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

COMMONPROFILE

*.ForwardCLIin
IAM

Set to 1 if outgoing IAM should contain the Calling Line Identity, if available. Only applicable for BTNUP when interworking from other protocols. Values: 0 or 1.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.Forward
SegmentedNEED

Set to 0 to disable the forwarding of segmented NEED messages within the BTNUP_NRC protocol. If segmenting is disabled, all mandatory DPNSS information elements are packed into a single BTNUP NEED message. Values: 0 or 1.

Default: 1

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.FromField

Maps to trunk group property FromField. Displays the name used in the SIP "From" field when the calling party number is marked private. Value range: any alphanumeric string.

Default: anonymous

TRUNKGROUP

COMMONPROFILE

*.FT_Incoming
PFXdigitsInsert

This property indicates the number of digits in the string that is inserted before the diversion digits in a service string when the Cisco PGW 2200 Softswitch receives DPNSS messages in Feature Transparency mode.

Valid values: NULL or a digit string of 1 through 6 ASCII (0-9) characters

Default: NULL

DPNSS

DPNSS

*.FT_Incoming
PFXdigitsRemove

This property indicates the number of diversion digits in a service string that are removed when the Cisco PGW 2200 Softswitch receives DPNSS messages in Feature Transparency mode.

Valid values: 0 through 6

Default:0

DPNSS

DPNSS

*.FT_Outgoing
PFXdigitsInsert

This property indicates the number of digits in the string that is inserted before the diversion digits in a service string when the Cisco PGW 2200 Softswitch sends DPNSS messages in Feature Transparency mode.

Valid values: NULL, or a digit string of 1 through 6 ASCII (0-9) characters

Default: NULL

DPNSS

DPNSS

EISUP

*.FT_Outgoing
PFXdigitsRemove

This property indicates the number of diversion digits in a service string that are removed when the Cisco PGW 2200 Softswitch sends DPNSS messages in Feature Transparency mode.

Valid values: 0 through 6

Default: 0

DPNSS

DPNSS

EISUP

*.gapInclude

Indicates whether or not to include the Generic Address Parameter in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.Gateway
Announcement
PackageSupport

Indicates whether the gateway supports the MGCP Announcement package.

Valid values:

0 = Announcement package is not supported

1 = Announcement package is supported

Default: 1

MGCP

H248

MGCP

*.GatewayAnn
Support

Specifies whether the gateway pool supports playing an announcement package to the IP side. Valid values:

0—Not supported

1—Supported

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.GatewayCodec
Support

Specifies whether the gateway pool supports transcoding for IP-to-IP traffic. Valid values:

0—Not supported

1—Supported

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.GatewayDTMF
Support

Describes the DTMF capability support for a gateway pool. Valid values:

0—Not supported

1—RFC 2833

2—Inband and RFC 2833

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.GatewayName

Used to identify the Gateway in the CDR record, that is whatever this value is set to will be placed in the CDR.

Default: N/A

AVM

MGCP

SGCP

VSI

AVM

H248

MGCP

SGCP

VSI

*.GatewayPool

Associates the default gateway pool with an IP trunk group so that media can be anchored on this gateway pool.

Valid values: Any integer from 0-9999

Default: 0 (indicates that there is no gateway pool associated with this IP trunk group)

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GatewayRBToneSupport

Indicates whether gateway ringback tones are supported by the remote gateway on a given trunk group and connection type. Valid values:

0 —Dose not support local tone application

1 —Local tone application support for MGCP/EISUP calls using MDCX connection method

2 —Local tone application support for MGCP/EISUP calls using RQNT connection method

3 —Local tone application support for MGCP/EISUP and MGCP/MGCP calls using MDCX connection method

4 —Local tone application support for MGCP/MGCP calls using MDCX connection method

5—Enable calls to work as a hairpin call with no ring-back tone

Note An incorrect configuration mismatch on this property can result in calls without ringback tones applied.

Note For a value of 1 or 2, the ring back tone is not supplied toward the PSTN side if PI=8 is present in the Alert or Call Progress messages coming from the H.323 side.

Note For a value of 3 or 4, hairpin calls, which originate and terminate on the same IOS gateway, the hairpin call function is disabled for the trunk group. All MGCP terminating calls are treated as non-hairpin calls, and local ring back tone is supported.

Default: 0

Property values 3 and 4 are added in software Release 9.5(2)

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Gateway
SelectionMethod

Specifies the border gateway selection method within a gateway pool. Valid values:

0—Sequence

1—Round robin

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.GatewayTone
Support

Specifies whether the gateway pool supports playing a tone to the IP side. Valid values:

0—Does not support tone

1—Supports tone

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.GatewayVideo
Support

use this property to control whether a gateway pool supports video traffic.

Valid values: boolean (0 = does not support, 1 = supports).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

GWPOOLPROFILE

*.Generate
Redirection
Number

Determines whether the Cisco PGW 2200 Softswitch includes the redirection number in the Address Complete Message (ACM) SS7 message.

Note This property was introduced in release 9.5(2), patch gs69nn62.

Valid values:

0 = redirection number is not included in the ACM message

1 = redirection number is included in the ACM message

Default: 1

TRUNKGROUP

SS7-ITU

COMMONPROFILE

*.GenNumInclude

Enables or disables the mapping of the Generic Number to the user field of a P-ASSERTED-ID Header in a SIP INVITE.

Valid Values:

1—Map the Generic Number in IAM to the user field of the P-ASSERTED-ID in a SIP INVITE. (Generic Number Handling Enabled)

0—Do not map the Generic Number to the user field of the P-ASSERTED-ID in a SIP INVITE. (Generic Number Handling Disabled)

Default Value: 0

Property Domain: SIP PROFILE

Protocol Family: SIP

Provisioning example:

mml> 
prov-ed:profile:name="sip-prof1",GenNumInclude="1"
 
        

Note To enable the Generic Number Handling feature, provision the mapclitosipheader property to the value 3.

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GenTimerT1

Maps to trunk group property GenTimerT1. The T1 timer value (in milliseconds) for SIP messages other than INVITE. Value range: any value greater than 0.

Default: 500

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GenTimerT2

Maps to trunk group property GenTimerT2. The T2 timer value (in milliseconds) for SIP messages other than INVITE. Value range: any value greater than 0.

Default: 4000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GLARE

Call Collision Handling. Value range:

0 = No glare handling; also known as yield to all double seizures. Call collision results in a REL sent to both calls.

Note Both ends of a link can be given this option.

1 = The Cisco PGW 2200 Softswitch has control of all circuits and any call collisions are handled by this Cisco PGW 2200 Softswitch. It ignores incoming IAMs and proceeds with its own calls as normal.

Note Only one end of a link can be designated with this option.

2 = Highest point code controls the even circuits. Depending on the OPC of the Cisco PGW 2200 Softswitches, the side that has the higher point code will control the even circuits, while the side with the lower point code will control the odd circuits.

Note Both ends of a link can be given this option.

3 = No control. The Cisco PGW 2200 Softswitch specified with this option does not control any circuits. The Cisco PGW 2200 Softswitch accepts incoming IAMs from the side with control.

Note This option is usually used along with the remote node designated with control.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.gnInclude

Indicates whether or not to include the Generic Name in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

This property applies to ANSI SS7 only. The applicable MDO files are ANSISS7_2K, ANSISS7_92, ANSISS7_C2, ANSISS7_C3, ANSISS7_E1, ANSISS7_STANDARD, and GR317.

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.GRA2

Determines if paired (0) or single (1) group reset acknowledgments (GRAs) are required before the reset is considered successful. Only applicable to ANSI SS7, IBN7, and CTUP protocols. Values: 0 or 1.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.grprofile

Contains a pointer to a GRPROFILE.

Valid values: String. Enter the name of an existing GRprofile.

Default value: NULL

Dynamically reconfigurable: Yes

EISUPPROFILE

SIPPROFILE

*.GRSEnabled

This property is assigned to an SS7 point code type signal path. Enables Group Reset and Blocking procedure at point code initialization. Synchronizes the Cisco PGW 2200 Softswitch bearer channel blocking state with that of the end office.

If True, GRS messages are sent for all CICs associated with the point code. If False, GRS messages are not sent. Values: true or false.

Default: false

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.GRSonSSC
Enabled

This property (available in software Release 9.4(1) patch 8 and above) is assigned to an SS7 point code type signal path. Enables Group Reset on Service State Change procedure at point code initialization. Values: false or true.

Note When the far end receives the GRS message, any active calls are released on the point code, as per ITU-T Recommendation Q.764.

If true, the GRS message is sent to the far end point code for all CICs associated with the point code after the point code was put in-service again.
If false, the GRS message is not sent.

Default: false

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.GtdCapTypeProp

This property is used by the Cisco PGW 2200 Softswitch as a pointer to the subset of GTD parameters that the user desires to support. Value range: t0 (no GTD support) to any string of 1 through 20 characters that identifies a GTD parameter string.

Default: t0

DPNSS

ISDNPRI

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

*.GtdMsgFmt

Indicates the GTD message format mode. The format can be only compact. Compact mode is the short format and the field names are not passed in the GTD parameter string. Value: c (compact).

Default: c

DPNSS

ISDNPRI

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GWDefaultATMProfile

Defines an initial list of profiles for a given trunk group to use for ATM profile negotiation.

Valid values:

A list of profile names separated by semicolons such as <Profile1>;<Profile2>;<ProfileN>.

NULL

Default value: NULL

Note If this property is set to NULL, the Cisco PGW 2200 Softswitch does not influence ATM profile negotiation.

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GWDefault
AudioCodecString

Gateway default audio codec string. Enables the IOCC-MGCP to send the ordered series of codec choices separated by semicolons. Refer to your gateway documentation for a list of supported codec names. The following values represent some of the more common codec names.

Values: NULL, G.711a, G.711u, G.729, G.729a, and G.729b

Additional values: G.726-32, G.726-24, G.726-16, G.729b-L, G.723.1-H, G.723.1-L, G.723.1a-L, G.GSM-F, G.GSM-H, and G.GSM-eF

Default: NULL

This property is added in software Release 9.8(1).

H248

MGCP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GWDefault
CodecString

Note This property is deleted in software Release 9.8(1).

Enables the IOCC-MGCP to send the ordered series of codec choices separated by semicolons. Refer to your gateway documentation for a list of supported codec names. The following values represent some of the more common codec names.

Values: NULL, G.711a, G.711u, G.729, G.729a, and G.729b.

Default: NULL

MGCP

TRUNKGROUP

*.GWDefaultVideoCodecString

Gateway default video codec string. Enables the IOCC-MGCP or IOCC-H248 to send the ordered series of codec choices separated by semicolons. Refer to your gateway documentation for a list of supported codec names. The following values represent some of the more common codec names.

Values are: NULL, H.264; H263; H261; H263-1988; JPEG; MPV; CelB; MP2T and nv.

Default: NULL

This property is added in software Release 9.8(1).

H248

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.GWNetwork
Continuity

This property enables or disables the network continuity test on the VISM. Values: 0 or 1.

Default: 0

MGCP

H248

MGCP

*.GWProtocol
Version

The MGCP protocol version to use when communicating with the gateway.

Values: MGCP 0.1 or MGCP 1.0, which was added in software Release 9.5(2).

Default: MGCP 0.1

MGCP

H248

MGCP

*.h248BulkAudit

This property indicates whether bulk audit is supported on the associated gateway.

Valid values (boolean):

0 = not supported

1 = supported

Default value: 1

Dynamically reconfigurable: yes

TRUNKGROUP

H248

*.h248CongestionEnable

This property specifies whether a congestion control procedure is enabled for that GW.

Valid values (boolean):

0 = not enabled

1 = enabled

Default value: 0

Dynamically reconfigurable: yes

TRUNKGROUP

H248

*.h248Domain
NameRemote

This property specifies the default H.248 remote domain name. Use it to append to the audit command and send it to the remote gateway.

Value range: any valid domain name or NULL.

Valid values: string (up to 127 characters)

Default value: NULL

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.H248Gateway
ReserveValue

Note This property is deleted in Release 9.8S6P6 and later.

This property allows H.248 to send ADD commands with the Reserve Value of on or off to indicate whether the MG should reverse resource or not. This property applies only to the originating MG; for the terminating side, the Reserve Value is always off.

Valid values:

0 = do not reserve resource

1 = reserve resource

Default value: 0

Dynamically reconfigurable: yes

TRUNKGROUP

H248

TRUNKGROUP

COMMONPROFILE

*.h248GWStdby
HeartbeatInterval

This property specifies the interval time, in seconds, that enables the Cisco PGW 2200 Softswitch to send a heartbeat to complete a health check on the remote gateway using the standby IP link.

Valid values: integer (0 to 30 seconds)

Default value: 30

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248inactivity
timer

This property specifies the allowable period of silence in milliseconds.

Valid values: integer (greater than 1000)

Default value: 5000

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248initialrtt

This property indicates the H.248 initial RTT (Round-Trip Time) value in milliseconds.

Valid values: integer (larger than 10)

Default value: 1000

Subsystem: MEGACO IOCC

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248LocalIpPollCount

This property specifies a poll count that defines the number of attempts to reach the remote GW for each configured local IP interface.

Valid values: integer (0 to 30)

Default value: 6

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248longtimer

This property indicates the H.248 long timer period.

Valid values: integer

Default value: 30

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248maxretries

This property indicates the maximum number of retransmissions that can be performed by the peer.

Valid values: integer (from 7 to 11)

Default value: 11

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248mgcexec
timer

This property is used in calculating the normal Cisco PGW 2200 Softswitch execution time (measured in milliseconds). This property specifies the interval at which the Cisco PGW 2200 Softswitch sends a Transaction Pending message back to the MG if a transaction request on the Cisco PGW 2200 Softswitch is pending.

Valid values: any integer

Default value: 500

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248mgcpend
limit

This property indicates the number of transactions pending that can be received from the Cisco PGW 2200 Softswitch.

Valid values: integer

Default value: 10

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248mgcprov
resptimer

This property sets the provisional response timer value (measured in milliseconds). The default value is the normal Cisco PGW 2200 Softswitch execution time plus network delay.

Valid Values: any integer

Default Value: 600

Dynamically Reconfigurable: no

TRUNKGROUP

H248

*.h248mgexec
timer

This property specifies the interval at which the Cisco PGW 2200 Softswitch receives a response to transactions from the MG. Network delay is excluded.

Valid values: any integer

Default value: 500

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248mgpend
limit

This property indicates the number of transactions pending that the Cisco PGW 2200 Softswitch can receive.

Valid values: integer

Default value: 10

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248profilename

This property specifies the profile name that defines how the Cisco PGW 2200 Softswitch uses the H.248.1 protocol and the functionality that the MG supports. The profile specifies the H.248.1 options used.

Valid values: string (up to 64 characters)

Default value: NULL

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248profile
version

This property specifies the H.248 profile version.

Valid values: integer (1 to 99)

Default value: 1

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248RemoteIp
PollCount

This property specifies a poll count defining the number of retry audit messages that the Cisco PGW 2200 Softswitch sends to the remote gateway.

Valid values: integer (0 to 30)

Default value: 72

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.h248TimerT1

This property specifies the interval (in milliseconds) at which the MG sends congestion notification to Cisco PGW 2200 Softswitch if the MG is in a congestion state.

Valid values: integer (0 to 100)

Default value: 0

Dynamically reconfigurable: yes

TRUNKGROUP

H248

*.h248txnpend
respcount

This property indicates the number of pending transactions that can be received from the MG/Cisco PGW 2200 Softswitch.

Valid values: integer

Default value: 11

Dynamically reconfigurable: no

TRUNKGROUP

H248

*.H323Adjunct
Link

Identifies an EISUP link that is connected to an H.323 adjunct platform. Values are: 0 (EISUP link is not connected to an H.323 adjunct platform) or 1 (an EISUP link is connected to an H.323 adjunct platform).

Default: 0

EISUP

EISUP

*.H323Destination

Identifies the primary and alternative IP Address and Port of the H323 destination.

Valid Values:

The primary and the alternative IP address and port of the H323 destination, in the format xxx.xxx.xxx.xxx[:port][xxx.xxx.xxx.xxx:port]

Default value:

NULL

This value indicates the Non-RAS feature is inactive on this trunk group.

Dynamically reconfigurable: Yes

This property is added in software Release 9.7(3).

EISUP

EISUP

EISUPPROFILE

COMMONPROFILE

*.HandlePres
Unavail

When Presentation Restricted Indicator is set to address unavailable, remove address digits from calling party number. Otherwise keep the address digits intact. Value range: T (true) or F (false).

EISUP

SS7-ANSI

SS7-ITU

EISUP

SS7-ANSI

SS7-ITU

*.HoldTimer

Indicates the maximum time length (in milliseconds) a SIP call can be put on hold. Maps to trunk group property HoldTimer. Value range: any value greater than 0.

Default: 300000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

*.hopOn

A flag indicating whether or not to enable the hop counter. Values: 0 (for no) or 1 (for yes).

Default:1

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.InhibitIncomingCallingName
Display

Inhibits support of incoming calling name display in DPNSS and EISUP(HSI) protocols. Values are: 1 inhibit incoming calling name display or 0 enable incoming calling name display.

Default: 0

This property is added in software Release 9.6(1).

DPNSS

EISUP

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

COMMONPROFILE

*.InhibitIncomingConnectedName
Display

Inhibits support of the incoming connected name display for call transfer in DPNSS and EISUP (HSI) protocols. Values are: 1 inhibit outgoing connected name display or 0 enable outgoing connected name display.

Default: 0

This property is added in software Release 9.5(2).

DPNSS

EISUP

TRUNKGROUP

DPNSS

EISUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InhibitIncomingConnectedNumberDisplay

Inhibits support of the incoming connected number display for call transfer in DPNSS and EISUP (HSI) protocols. Values are: 1 inhibit outgoing connected name display or 0 enable outgoing connected name display.

Default: 0

This property is added in software Release 9.6(1).

DPNSS

EISUP

TRUNKGROUP

DPNSS

EISUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InhibitOutgoing
CallingName
Display

Inhibits support of outgoing calling name display in DPNSS and EISUP(HSI) protocols. Values are: 1 inhibit incoming calling name display or 0 enable incoming calling name display.

Default: 0

This property is added in software Release 9.6(1).

Note This property is not implemented on Release 9.7(3).

DPNSS

EISUP

TRUNKGROUP

*.InhibitOutgoingConnectedName
Display

Inhibits support of the outgoing connected name display for call transfer in DPNSS and EISUP (HSI) protocols. Values are: 1 inhibit outgoing connected name display or 0 enable outgoing connected name display.

Default: 0

This property is added in software Release 9.5(2).

DPNSS

EISUP

TRUNKGROUP

DPNSS

EISUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InhibitOutgoingConnectedNumberDisplay

Inhibits support of the outgoing connected number display for call transfer in DPNSS and EISUP (HSI) protocols. Values are: 1 inhibit outgoing connected name display or 0 enable outgoing connected name display.

Default: 0

This property is added in software Release 9.6(1).

DPNSS

EISUP

TRUNKGROUP

DPNSS

EISUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InhibitPasson

Specifies whether to inhibit pass-on of unrecognized messages/parameters. Values are:

0 = pass on unrecognized messages/parameters (allow pass-on)

1 = do not pass on unrecognized messages/parameters (inhibit passon)

Default: 0

EISUP

*.InhibitSipFromMapping

This property determines the mapping from the incoming SIP message to the ISUP CLI. This property is for PSTN emulation services (SIP/SIP-I).

If the remote party ID or P-Asserted-ID header is present and the InhibitSipFromMapping property = 1, then disable mapping the SIP From header to the generic number. If the remote party ID or P-Asserted-ID header is not present and the InhibitSipFromMapping property = 1, then disable mapping the SIP From header to the calling party number.

Valid Values:

0—If the PAID/RPID E164 number is present, map the PAID/RPID to CgPN, map the E164 number in username in From header to GN (additional CgPN). If the PAID/RPID E164 number is not present, map the E164 number in username in From header to CgPN.

1—Ignore the From header, map PAID/RPID E164 number to CgPN.

2—Ignore the PAID/RPID, map the E164 number in username in From header to CgPN.

3—If the PAID/RPID E164 number is present, map the PAID/RPID to CgPN, map the E164 number in Display name in From header to GN (additional CgPN). If the PAID/RPID E164 number is not present, map the E164 number in username in From header to ISUP CgPN, and map the E164 number in displayname in From header to GN (additional CgPN)

4—If the PAID/RPID E164 number is present, map the PAID/RPID to CgPN, map the E164 number in username in From header to GN (additional CgPN). If the PAID/RPID E164 number is not present, ignore the From header.

5—If the PAID/RPID E164 number is present, map the PAID/RPID to CgPN, and map the E164 number in username in From header to GN (additional CgPN). If the PAID/RPID E164 number is not present, map the E164 number in the username in From header to ISUP CgPN, and map the E164 number in displayname in From header to GN (additional CgPN).

Note The value 4 is available only in Release 9.7(3). The value 5 is available only in Release 9.8(1).

Default Value: 0

SIP

SIP

SIPPROFILE

COMMONPROFILE

*.InitEndpoints
AsEnabled

Specifies if the Cisco PGW 2200 Softswitch (the engine) initializes its endpoint objects (corresponding to those on the gateway) as enabled or disabled. For gateways that send RSIP messages at initialization to inform Cisco PGW 2200 Softswitch of their endpoint state, set to False; all others set to True. This property value is dynamically editable using MML commands.

Values: TRUE (1) or FALSE (0)

Default: True

MGCP

H248

MGCP

*.InSessionTimer

Indicates the maximum session time (in milliseconds) allowed for a SIP call that originated by the Cisco PGW 2200 Softswitch. Maps to trunk group property InSessionTimer. This value may require being increased to 1800000 to reduce performance impact. Value range: any value greater than 0.

Note In software Release 9.4(1), this is the minimum session time interval.

Default: 1800000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.insideVrfName

Specifies the VrfName for leg 2 or leg 3 in an IP-to-IP gateway call.

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

DOMAINPROFILE

*.insipheadertable

Contains a pointer to an inbound SIP header table.

Valid values: String. Enter the name of an existing inbound SIP Header table.

Default value: NULL

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

DOMAINPROFILE

*.InviteAttempts

Defines the transmission times for INVITE requests.

Valid Values: integer (1-15)

Default: 7

Dynamically Reconfigurable: yes

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InviteTimerT1

Indicates the T1 timer (in milliseconds) for the INVITE message, as specified for SIP. Maps to trunk group property InviteTimerT1. Value range: any value greater than 0.

Default: 1000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.InviteWaitTimer

Defines the timer (in milliseconds) of waiting for final response of INVITE requests.

Valid Values: integer (10000-500000)

Default Value: 200000

Dynamically Reconfigurable: yes

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

IOCC.chkPtPort

IP port number used to checkpoint events to standby MGC. Value range: 1025 to 65535. This cannot conflict with other IP port assignments.

Default: 0

IOCC

IOCC

IOCC.port

IP port number used to send and receive events. This is generally overridden by a protocol (for example, RLM). Value range: 1025 to 65535. This cannot conflict with other IP port assignments.

Default: 3000

IOCC

IOCC

*.IOI

Specifies the IOI for a trunk group. This property overrides the *.IOI parameter value in the XECfgParm.dat file. This property can be provisioned on a trunk group, in a SIP or EISUP profile, or a domain profile.

Valid values: string (1 to 63 characters) or none.

Default value: none.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ipinscreening

Indicates whether the Cisco PGW 2200 Softswitch processes incoming SIP and EISUP traffic using the incoming trunk groups defined using the ipinmapping provisioning component.

Valid values:

0 = The ipinmapping function is disabled.

1 = The ipinmapping function is enabled. The Cisco PGW 2200 Softswitch discards incoming traffic that does not match an existing ipinmapping entry. The Cisco PGW 2200 Softswitch evaluates messages using the source IP address and destination port.

2 = The ipinampping function is enabled. The Cisco PGW 2200 Softswitch processes incoming traffic that does not match an existing ipinmapping entry using the default incoming trunk group.

Note If a message matches multiple ipinmapping table criteria, the Cisco PGW 2200 Softswitch applies the most detailed match.

Default value: 0

EISUP

SIP

EISUP

SIP

*.IPTermNum
Groups

According to the ETSI profile, an RTP termination ID conforms to the format ip/group id/interface id/id. This property specifies the largest group number provisioned on this gateway.

Valid values: An integer from 0-255. (0 specifies that the group field for the RTP termination ID is not used.)

Default: 255

This property is added in software Release 9.8(1).

H248

*.IPTermNum
Interfaces

According to the ETSI profile, an RTP termination ID conforms to the format ip/group id/interface id/id. This property specifies the number of interfaces that are provisioned for this gateway.

Valid values: an integer from 0-8.

Default: 0. (0 specifies that the interface field for RTP termination ID is not used.)

This property is added in software Release 9.8(1).

H248

*.IPTermNum
Terms

According to the ETSI profile, an RTP termination ID conforms to the format ip/group id/interface id/id. This property specifies the number of terminations that are allowed in a particular group ID and interface ID.

Valid values: an integer from 1-1364

Default: 1364

This property is added in software Release 9.8(1).

H248

*.IsdnNSF

Indicates the network specific facilities parameter for ISDN PRI.

Specify an integer from 0-256.

0-255: Directly mapping to 0x00-0xFF in the outgoing message.

256: No NSF in the outgoing message.

Default: 256

TRUNKGROUP

TRUNKGROUP

*.isuptmrProfile

This property indicates the Level 2 ISUP TMR profile that is attached to a SIP profile.

Valid values: any string up to 128 characters in length.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

*.IsupToSipRatio

Set the ratio of Max_Forwards to Hop Counter for a call from ISUP to SIP.

Valid values: 0 through 4. 0 indicates the mapping does not function.

Default value: 0

SIP

SIP

*.IsupTransEarly
ACMEnable

Indicates a special Address Complete Message (ACM) to PRI message mapping when an early ACM does not map to a PRI message. Values: 0 no mapping (default), 1 PROGRESS message is sent with Progress description value of 9. Enable GTD to ensure ISUP transparency, or 2 ALERTING message sent.

Default: 0

ISDNPRI

ISDNPRI (BRI)

*.IsupTransEarly
BackwardDisabled

Indicates if the egress Cisco PGW 2200 Softswitch is to send an end-to-end message, called Early Backward Call Setup Message, immediately after receiving the call setup message with GTD information about the outgoing protocol variant. Values: 0 (enable) or 1 (disable).

Default: 1

ISDNPRI

DPNSS

ISDNPRI (BRI)

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Isup
Transparency
Disabled

Permits disabling of the ISUP Transparency feature for a particular trunk group. Values:1 (True) the ISUP Transparency feature is disabled, or 0 (False) the ISUP Transparency feature is enabled.

Default: 1

SS7-ANSI

SS7-ITU

TRUNKGROUP

SS7-ANSI

SS7-ITU

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ItpAction
Request

The ItpActionRequest property indicates that the Cisco PGW 2200 Softswitch should send a customized SIP invite to the ITP to return the location of a mobile subscriber. Setting this property to map-app indicates that the Cisco PGW 2200 Softswitch should send a customized SIP invite to the ITP to return the location of a mobile subscriber. The customized SIP invite causes the ITP to send a MAP query to the service provider HLR for the mobile subscriber's current mobile station roaming number (MSRN). The Cisco PGW 2200 Softswitch then routes the call to the closest Gateway MSC based upon the new MSRN.

If the Cisco PGW 2200 Softswitch is unable to optimize the call routing based on the MSRN, it continues to route calls based on using the mobile subscriber's MSISDN (telephone number). The Cisco PGW 2200 Softswitch routes calls based on an MSISDN using cause analysis.

Values: Null or map-app

Default: Null

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.jipDefault

Indicates the default JIP value to be sent when jipInclude = 1 and no JIP value is present. If the value is 0, jipDefault is treated as if no value is present. Value range: 0 through 9.

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.jipInclude

Indicates whether or not to include the Jurisdiction Information Parameter (JIP) in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.lapdDropErr

Boolean to determine if some LAPD sequence errors are discarded. This is used in large IP networks where the latency may cause LAPD sequence errors. According to Q.921, this will cause the link layer to reset. This parameter allows sequence errors to be discarded without resetting the link. Values: true or false.

Default: false.

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.lapdKval

Number of outstanding frames in Q.921 transmission window. Value range: 1 to 127.

Default: 7

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.lapdN200

Maximum number of retransmissions of a Q.921 frame. Value range: 0 to 10.

Default: 6

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.lapdN201

Maximum number of octets in a Q.921 frame.

Default: 260

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.lapdT200

Maximum wait time for a LAPD frame acknowledgement before retransmission. Value range: 10 to 60, in tenths of a second increments.

Default: 10

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.lapdT203

Maximum time the Q.921 link is idle before sending a frame. Value range: 50 to 600, in tenths of a second increments.

Default: 500

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.layerRetries

Maximum number of retransmissions for TCAP/SCCP queries. Value range: 0 through 5, where 0 = No retries.

Default: 2

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.layerTimer

Time (in tenths of a second) to wait for a response from adjacent layer (SS7 controller, TCAP to SCCP); tailor when layers are not resident on same processor. Value range: 0 through 10, where 0 = Disabled and 10 = 1 second.

Default: 10

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.LocalAnn
Behavior

Allow suppression of the early ACM (indicating in-band information is available) to allow overlap dialing to begin the pre-call announcement as soon as the route is determined, and still allow additional address information to be received in SAMs.

Values: 0 (disabled) or 1 (enabled),

Default: 0

Valid values are:

1—Play announcement after enough digits have been received to determine a route. Early ACM is not sent before playing the announcement (it is assumed that the voice path is already cut back after IAM). The call is routed after the announcement is played.

Note When overlap sending is also used, depending on the number dialed, some users might receive the pre-call announcement while the final digits are being dialed.

2—route the call after enough digits have been received to determine a route. Play the announcement after an address complete indication (ACM) is received from the terminating side. This method was introduced by this feature.

Note When you are using this option, the Cisco PGW 2200 Softswitch might force an enbloc, which can result in an unacceptable post-dial delay.

This property is added in software Release 9.5(2). In Release 9.7(3), this property name was changed from AnnSuppressInbandInfo to LocalAnnBehavior.

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.LocalPort

Maps to trunk group property LocalPort. Indicates the UDP port used by Cisco PGW 2200 Softswitch to send or receive SIP messages. Valid range: any valid port number greater than 1024.

Default: 5060

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.LocationNumber

The default outgoing number used if a location number is not present in an incoming call. (This is used in protocols Q761 and Q767.)

Default: 0

SS7-ITU

SS7-ITU

COMMONPROFILE

*.LoopAvoidance
Counter

Loop Avoidance counter for DPNSS. Value range: 0 through 25.

Default 0.

This property is added in software Release 9.6(1).

DPNSS

TRUNKGROUP

DPNSS

TRUNKGROUP

COMMONPROFILE

*.LoopAvoidance
Support

Indicates if the Loop Avoidance feature is supported in DPNSS or not. Values are: 0 not supported or 1 supported.

Default: 0

This property is added in software Release 9.6(1).

DPNSS

TRUNKGROUP

DPNSS

TRUNKGROUP

COMMONPROFILE

*.LRNDigitCC
Prefix

This property specifies a country code digit string to which the RNDigitCCrm is compared if the NOA code is International. If the digits match, the matched digits are removed from the location routing number and the NOA code is set to National. This is an incoming trunk group property. This property is for PSTN emulation services (SIP/SIP-I).

Valid values: NULL or any string up to 5 digits.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.LRNDigitCCrm

This property specifies a country code digit string to which the RNDigitCCrm is compared if the NOA code is International. If the digits match, the matched digits are removed from the location routing number and the NOA code is set to National. This is an incoming trunk group property. This property is for PSTN emulation services (SIP/SIP-I).

Valid values: NULL or any string up to 5 digits.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MacCBRequest

Maximum number of call back requests allowed in the queue for the CTI sigpath. Value range: 1 through 50.

Default: 10

This property is added in software Release 9.6(1).

CTI-QBE

CTI-QBE

*.MapCLItoSip
Header

Determines the mappings from the ISUP calling party number to the outgoing SIP message. Valid Values:

0—The calling party number is put in the outgoing SIP From header if number presentation is allowed. If the calling party number presentation is restricted, then the SIP outgoing From header is also controlled by the cgpnInclude property.

If cgpnInclude = 0, and the SIP network is un-trusted, the From header has SIP URI as: Anonymous <sip:Anonymous@anonymous.invalid>

If cgpnInclude = 1, and the SIP network is trusted, and honors the anonymous setting by not passing the CLI to the SIP end point, the From header has URI as Anonymous <sip:CGPN@PGW_HOST>

1—The calling party number is mapped to the remote party ID, with screen and privacy values. If an additional calling party number is present in the generic number, it is mapped to the SIP From header.

2—Map the calling party number to the Remote-Party-ID header only when the calling party number presentation is allowed. For handling the additional calling party number in the generic number, the operation is the same as for a value of 1.

3—The calling party number is mapped to the P-Asserted ID, with privacy header value ID, if necessary. If an additional calling party number is present in the generic number, it is mapped to the SIP From header.

Note If the calling party number presentation is allowed, there is no privacy header. If the calling party number presentation is restricted, there is a privacy header with a value ID.

4—Map the calling party number to the P-Asserted ID header only when the calling party number presentation is allowed. For handling the additional calling party number in the generic number, the operation is the same as for a value of 3.

5—MAP_ACLI_INTO_FROM_AND_PAID. For ISUP-PGW-SIP calls, the PAID and From headers of Invite message are mapped from ACgPN of IAM.

Note The value 5 is added in software Release 9.8(1) S7P7.

Default Value: 0

SIP

TRUNKGROUP

SIP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

MapRNMethod

Determines the mappings between the EISUP or ISUP RN and the SIP message headers or EISUP RN.

Valid Values:

0—Do not map the RN to the SIP header. Do not map the RN to the EISUP RN parameter.

1—Map the RN to the Diversion header. Map the RN to the EISUP RN parameter.

2—Map the RN to the Diversion header only when RN presentation is allowed. Map the RN to the EISUP RN parameter only when the RN presentation is allowed.

Default Value: 1

EISUP

SIP

TRUNKGROUP

EISUP

SIP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MaxACL

Indicates the Cisco PGW 2200 Softswitch congestion level (if greater than zero) in the ISUP release message using the ACL parameter. The purpose of this parameter is to map between the Cisco PGW 2200 Softswitch congestion levels and the destination switch congestion levels. This mapping is as follows:

   Max ACL         Current Machine      ACL Value 

configuration        Congestion        in Release 

    value                Level             Message 

--------------------------------------------------

      0              0,1,2,3         Not Present

      2                 0            Not Present

                        1                1

                        2                2

                        3                2

      3                 0            Not Present

                        1                1

                        2                2

                        3                3


Valid values: 0, 2, or 3.

Default: 3

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.MaxForwards

Maps to trunk group property MaxForwards. Indicates the maximum number of SIP forwards allowed. Value range: any value greater than 0.

Default: 70

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.maxMessage
Length

Maximum length of message to MTP3. This value must be less than the value for mtp2MaxMsuFrmLen. Value range: 0 through 272.

Default: 250

SS7-ANSI

SS7-ANSI

*.MaxRedirectCnt

Maps to trunk group property MaxRedirectCnt (maximum redirect count). Indicates the maximum number of SIP message redirections allowed. Value range: any value greater than 0.

Default: 5

TRUNKGROUP

COMMONPROFILE

*.MaxSubscriptionDuration

Sets the maximum duration of a subscription (in milliseconds) before a re-subscription is required.

Value range: Any integer from 0 through 3600.

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MGCDomain

Maps to trunk group property MGCDomain. Indicates the Cisco PGW 2200 Softswitch domain name used in SIP messages. Value range: any valid domain name or NULL.

Default: NULL

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MgcpBehavior

Regulates the Cisco PGW 2200 Softswitch engine behavior to allow different MGCP gateway types to return different codes for the same error. Values: 0 or 2.

0—No action

1—Resolves a connection conflict between the Cisco PGW 2200 Softswitch and a media gateway to allow a circuit to be used after a CRCX failure (return code 501) by clearing the call; VISM and MGX8260.

2—Resolves a connection conflict between the Cisco PGW 2200 Softswitch and a media gateway to allow a circuit to be used after a CRCX failure (return code 502) by forcing a delete and reconnection; 5300, 5400, other IOS-based servers, and VXSM.

Default: 0

Note Additional differences can be handled by adding enumerated values.

MGCP

MGCP

*.mgcpBulkAudit

Specifies whether bulk audit is supported. Valid values:

1—Indicates that bulk audit is supported on a gateway.

0—Indicates that bulk audit is not supported on a gateway.

Valid values: 0 or 1

Default value: 0

MGCP

MGCP

*.mgcpDomain
NameLocal

Specifies the MGCP local domain name or IP address the system uses in the N: tag. The Cisco PGW 2200 Softswitch includes an N: tag in the outbound NTFY message to identify the domain or IP address of the active Cisco PGW 2200 Softswitch after a switchover.

If you set the value to a domain name, such as pgw.cisco.com, the system sets the N: tag as N: <domain name>: port, for example, N: pgw.cisco.com:2427.

If you set the value to activelink, the system sets the N: tag as N: <IP address of the active link>:port, for example, N: 10.22.33.33:2427. In general, there are two IP links for an MGCP sigpath, one active and the other standby. If you specify activelink, the system uses the active link for the N: tag.

If you do not set a value, or you set the value to NULL, the system does not create an N: tag.

Value: String (domain name, activelink, or NULL)

Default: NULL

MGCP

MGCP

*.mgcpDomain
NameRemote

Default MGCP remote domain name. It is used to append to the audit command to send to the remote gateway.

Default: remote@name.net

MGCP

MGCP

*.mgcpGWRspAckTimeout

Enables the Cisco PGW 2200 Softswitch to discard respAcks in the buffer for which the gateway no longer expects acknowledgements. Value range: any positive value (in seconds).

Default: 30

Note Set this value to the same duration as the gateway's command/response timeout value.

 

MGCP

MGCP

*.mgcpGWStdby
HeartbeatInterval

This interval time, in seconds, enables the Cisco PGW 2200 Softswitch to send the standby heartbeat to complete a health check on the remote gateway. Value range: 0 to 30 seconds.

Default: 30 seconds

MGCP

MGCP

*.mgcpHeartbeat
Interval

Indicates how often the MGCP protocol should heartbeat the gateway. Value range: 0 through 1000.

Default: 1

Note To prevent MGCP IP links from flapping, set this to a minimum value of 4 when the Cisco PGW 2200 Softswitch 2200 call agent is working with a Cisco MGX8260.

MGCP

MGCP

*.mgcpLocalIp
InterfacePollCount

This poll count defines the number of attempts to be performed to reach the remote GW using each configured local IP interface. Value range: any positive value.

Default: 6

MGCP

MGCP

*.mgcpMaxRsp
AckToBuffer

Enables the Cisco PGW 2200 Softswitch to buffer the number of response acknowledgements specified by this property before tagging them in the K-parameter in the next mgcp command. Value range: 0 (disable) to any positive value.

Default: 0

MGCP

MGCP

*.mgcpRemoteIp
PollCount

This poll count defines the number of retry audit messages to be sent to the remote gateway. Value range: any positive value.

Default: 3

MGCP

MGCP

*.mgcpRetxCount

A limit on the number of retransmissions before declaring failure. (MGCP protocol.) Value range: 0 through 10.

Default: 3

MGCP

MGCP

*.mgcpRetxTimer

A limit on the time to wait for a response from a gateway before retransmitting the message. (MGCP protocol.) Value range: 0 through 60000.

Default: 2000

Note To prevent possible hung calls on a MGW, the recommended value is 4000.

MGCP

MGCP

*.MGCSipVersion

Maps to trunk group property MGCSipVersion. The version of SIP protocol supported by the Cisco PGW 2200 Softswitch. Value range: any valid SIP version.

Default: 2.0

Note For Cisco PGW 2200 Softswitch software earlier than Release 9.7, set this value to SIP/2.0.

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MidCallCodec
Select

Enables codec selection on SIP midcall media update messages such as ReINVITE and UPDATE. Values are:

0 (disable)

1 (enable)

Default: 0

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

*.MidCallCP
Interval

Enables or disables mid-call checkpointing. When it is enabled, you can specify the interval (in minutes) between checkpointing events in the connected state. Valid values: 0 (disabled) (default) through 60.

Default value: 0

This property is added in software Release 9.5(2).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MidCallService
CustID

This is a 4-digit, alphanumeric character string that indicates which dial plan is used for mid-call service analysis. If this property value is 0000, no mid-call service is supported. Valid range: 0000-any 4-digit alphanumeric character string.

Valid Values: 0000-any 4-digit alphanumeric character string.

Default: 0000

DPNSS

ISDNPRI

SIP

SS7-ANSI

SS7-ITU

DPNSS

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-ITU

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MinEvent
SubscribeDuration

Defines the minimum duration (in milliseconds) for which a telephony event can be subscribed.

Value range: 40 through 3600.

Default: 40

This property is added in software Release 9.4(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MlppNamespace

Presents namespaces that are supported on the SIP trunk. Individual namespaces are separated by commas.

For SIP to ISUP interworking, the system attempts to match namespaces defined by this property with namespaces included in the Resource-Priority Header of an INVITE message. If the system detects a match, it relays the MLPP information to the ISUP trunk. If the system does not detect a match, but does receive a Require message that contains a Resource-Priority tag, the system generates message 417-Unknown Resource-Priority Response.

Note This property does not apply to SIP to SIP interworking.

Valid value: For this implementation of the feature, the valid value is "q735".

Default value: " " (null)

This property is added in software Release 9.8(1) S10P10.

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MlppNI

Specifies the NI1 . For SIP to ISUP interworking, the system attempts to match the value of this property with the NI value in the MLPP Precedence parameter, which is included in a received IAM message.

If the system detects a match, it relays the information to the egress trunk. If the system does not detect a match, it ignores the MLPP information and does not relay it to the egress trunk.

Valid values: a Telephony Country Code (for example, "049" for German ISUPv2, which is the recommended value for this feature.)

Default value: " " (null)

This property is added in software Release 9.8(1) S10P10.

TRUNKGROUP

*.MlppSupport (for ISUP)

Instructs the system to relay or ignore MLPP information received in an IAM message over the ingress ISUP trunk.

Also instructs the system to relay MLPP information received from the ingress trunk to the egress ISUP trunk. Alternatively, the system ignores the MLPP information and does not relay the information to the egress ISUP trunk.

Valid values:

0—Do not relay MLPP information

1—Relay MLPP information

Default value: 0

This property is added in software Release 9.8(1) S10P10.

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MlppSupport (for SIP)

Instructs the system to relay or ignore MLPP information received in a SIP message over the ingress SIP trunk.

Also instructs the system to relay MLPP information received from the ingress trunk to the egress SIP trunk. Alternatively, the system ignores the MLPP information and does not relay the information to the egress SIP trunk.

Valid values:

0—Do not relay MLPP information

1—Relay MLPP information

Default value: 0

This property is added in software Release 9.8(1) S10P10.

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.MWIInvoke
TimerT1

A millisecond timer, as specified by ROSE, that is used to invoke the message waiting indicator (MWI) supplementary service. This property is used for communication with a VoIP gateway connected to a QSIG PBX. Valid values: 0 through 20000 (this value is in milliseconds)

Default: 15000

This property is added in software Release 9.5(2).

ISDNPRI

ISDNPRI (BRI)

*.MWIStringOFF

Number used within the network to turn off a message waiting indicator, specific to DPNSS signaling services. This property is used for communication with a VoIP gateway connected to a DPNSS PBX. Valid values: a string, with a minimum length of 1 and a maximum length of 32 characters.

Default: NULL

This property is added in software Release 9.5(2).

DPNSS

TRUNKGROUP

DPNSS

TRUNKGROUP

COMMONPROFILE

*.MWIStringON

Number used within the network to turn on a message waiting indicator, specific to DPNSS signaling services. This property is used for communication with a VoIP gateway connected to a DPNSS PBX. Valid values: a string, with a minimum length of 1 and a maximum length of 32 characters.

Default: NULL

This property is added in software Release 9.5(2).

DPNSS

TRUNKGROUP

DPNSS

TRUNKGROUP

COMMONPROFILE

*.NATTraversal
Enabled

Specifies whether the Cisco PGW 2200 Softswitch performs NAT traversal in an add or modify request. The detailed NAT traversal method depends on the provisioning of the sigPath property NATTraversalMethod.

Valid values:

0—NAT traversal is not enabled.

1—NAT traversal is enabled.

Default: 0

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.NATTraversal
Method

Specifies the NAT traversal method that the Cisco PGW 2200 Softswitch applies to the gateway.

Valid values:

0—Apply NAT traversal using the ETSI NAT traversal package.

1—Apply NAT traversal using the IP NAPT package according to H248.37.

Default: 0

This property is added in software Release 9.8(1).

ISDNPRI (BRI)

*.NatureOfAddr
Handling

Determines whether or not to perform preanalysis. Values: 0 or 1.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.NetSuspendResumeMap2Invite

Indicates whether or not the Cisco PGW 2200 Softswitch maps a mid-call ISUP SUSPEND/RESUME, with a network-initiated value, to a SIP Re-Invite.

Valid Values:

0—Do not map ISUP SUSPEND/RESUME to SIP Re-Invite

1—Map ISUP SUSPEND/RESUME (network initiate) to SIP Re-Invite (similar to Hold/TP service).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

*.NetworkType

Specifies whether the underlying network uses ATM or IP. The NetworkType parameter allows the Cisco PGW 2200 Softswitch to determine which protocol-specific parameters to send to gateways.

Note NetworkType populates the network type parameter (nt:) in the local connection parameters, which is used for the originating and terminating legs of all calls.

Valid values: 0 (IP), 1 (ATM), 2 (IN)

Default value: 0 (IP)

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.NFASImplicit
InterfaceId

Used when an incoming ISDN message containing a Channel identification information element identifier with bit 7 of octet 3 set to 0 (Interface implicitly identified) as the implied interface ID value. Value range: 0 through 127.

Default = 65535

This property is added in software Release 9.5(2).

ISDNPRI

ISDNPRI (BRI)

*.NonInviteRe
qAttempts

Defines the transmission times for non-INVITE requests

Valid Values: integer (1-15)

Default Value: 11

Dynamically Reconfigurable: yes

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Normalization

Normalization of dialed number to unknown. Set to 0 for disabled and 1 for enabled. Values: 0 or 1.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.notification
Include

Indicates whether or not to include the Notification parameter in the Call Progress (CPG) message. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.Npa

Numbering plan area. Indicates the NPA code associated with the incoming trunk group. Value range: 0 (none), or 200 through 999.

Default: 0

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.ocnInclude

Indicates whether or not to include the Original Called Number in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.OD32Digit
Support

Allows 32 digits and overdecadic digits support for the ANSI, Q.761, and Q.767 protocol variants. Values: 0 (disabled) or 1 (enabled).

Default: 1

This property is added in software Release 9.4(1).

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.OMaxDigits

Specifies maximum number of digits to receive for overlap digit processing for call origination from this traffic path. Value range: 0 through system maximum.

Default: 24

DPNSS

EISUP

ISDNPRI

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.OMinDigits

Specifies minimum number of digits to receive for overlap digit processing for call origination from this traffic path. Value range: 0 through system maximum.

Default: 0

DPNSS

EISUP

ISDNPRI

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.OmitCgPnFromUnavailable

Determines if mapping between the SIP From header to the IAM calling party number is enabled when the SIP message header From is "unavailable". Values are: 0 (enabled) or 1 (disabled).

Default = 0

This property is added in software Release 9.5(2).

SIP

SIP

*.OOverlap

Set to 1 to enable overlap signaling for call origination from this traffic path. Value range: 0 through system maximum.

Default: 0

DPNSS

EISUP

ISDNPRI

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

*.OrigCarrierId

Supplies the CarrierId digit string for a trunk group that can then be referenced against any CarrierID received in the incoming message. This is used to support the carrier screening capability, as handled in the protocol. Value range: up to five digits.

Default: 00

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.outboundDomainProfileSource

Indicates the source that the Cisco PGW 2200 Softswitch uses for the outbound domain name.

Valid values:

0 = If available, the Cisco PGW 2200 Softswitch uses the domain used for routing as introduced by the domain-based routing feature. Otherwise, the Cisco PGW 2200 Softswitch uses the domain of the SIP trunk group.

1 = The Cisco PGW 2200 Softswitch uses the domain of the SIP trunk group.

Default value: 0

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

*.OutSessionTimer

Maps to trunk group property OutSessionTimer. The maximum session time (in milliseconds) allowed for a SIP call terminated by the Cisco PGW 2200 Softswitch. This value may require being increased to reduce performance impact. Valid range: any value greater than 0.

Note In software Release 9.4(1), this is the maximum session expiration value.

Default: 1800000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.outsideVrfName

Specifies the VrfName for leg 1 or leg 4 in an IP-to-IP gateway call.

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

DOMAINPROFILE

*.outsipheader
table

Contains a pointer to an outbound SIP header table.

Valid values: String. Enter the name of an existing outbound SIP header table.

Default value: NULL

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.OverlapDigit
Time

Overlap interdigit timer. The time to wait for the rest of the digits.
Value range: 0 through 60.

Default: 6

DPNSS

EISUP

ISDNPRI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.OwnClli

Specifies the common language location identifier (CLLI).

Default: na

SS7-ANSI

SS7-ANSI

*.OwnRouting
Number

Defines the routing or network number of the Cisco PGW 2200 Softswitch in a PBX network that requires Route Optimization or Path Replacement capabilities. The presence or absence of this property indicates if this service is enabled/disabled for a signalling path.

Valid range: Alphanumeric string up to 32 digits.

Default: NULL

This property was added in software Release 9.6(1).

DPNSS

EISUP

ISDNPRI

TRUNKGROUP

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

COMMONPROFILE

*.PackageType

Maps to trunk group property PackageType. Determines MDL MGCP message handling according to the CAS trunk group package. Value range: any alphabetical string.

Default: BL

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.Play
Announcement

Specifies whether the Cisco PGW 2200 Softswitch plays an early announcement on a given trunk group. Valid values:

0—The announcement function is disabled for the trunk group.

An integer value greater than 0 specifies the Integer Announcement Identity.

Default value: 0

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.populateSDPInfoInCDR

Enables or disables the extraction of information from Session Description Protocol (SDP). Extracted SDP information is populated in call detail records (CDRs). Values: 0 (disabled) or 1 (enabled).

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.PostConnectToneDuration

Indicates the duration for which the tone is to be played in the bearer channel immediately after connect. Value range: 0 through 16000 (in milliseconds).

Default: 0

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.PostConnectToneValue

Indicates if the post-connect tone is to be played in the bearer channel immediately after connect. Value range: 0 through 12.

Default: 0

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.PropagateDelay
Counter

This property indicates the propagation delay increase value (measured in milliseconds) which the Cisco PGW 2200 Softswitch adds to the propagation delay of the incoming message. The outgoing message carries the calculation result. This property is for PSTN emulation services (SIP-I).

Valid values: integer (0 to 255).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

TRUNKGROUP

COMMONPROFILE

*.PropagateSvc
MsgBlock

Indicates the type of blocking messages supported. If true, protocols supporting group blocking send individual blocking messages. If false, protocols supporting group blocking continue to send group blocking messages.

Note This sigpath property is useful only for switching (nailed) solutions.

Values: true or false.

Default: false

DPNSS

ISDNPRI

RLM

DPNSS

ISDNPRI (BRI)

*.Protocolidand
VariantidProv

Indicates whether or not to carry variant information over EISUP. Valid values: 1(protocol and variant information will be carried), 0(only protocol information will be carried).

Default: 0.

EISUP

EISUP

*.QSIGTunnel
Variant

Controls the QSIG tunnel capability across outbound EISUP (HSI) interfaces and specifies which protocol variant is used.

Valid Values:

0—QSIG tunneling is disabled

1—QSIG tunneling is enabled

Default Value: 0

EISUP

TRUNKGROUP

EISUP

EISUPPROFILE

COMMONPROFILE

radiuskey

Radius Server shared secret key. Default: 0000000000000000.

LI

LI

radiusretrycount

The number of times the accounting packet need to be re-sent. Default: 3.

LI

LI

radiustimeout

The timeout to wait for a response from the mediation device, in milliseconds. Default: 5.

LI

LI

*.redirCapInclude

Indicates whether or not to include the Redirect Capability in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.redirCounter
Include

Indicates whether or not to include the Redirect Counter in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.RedirectingNbrMap

A flag used for passing the Original Called Number (OCN) or the Redirecting Number to the Redirecting Number field in the Q.931+ protocol. Values: 0 or 1.

Default: 0

DPNSS

ISNDPRI

DPNSS

ISNDPRI (BRI)

*.redirInfoInclude

Indicates whether or not to include the Redirection Info in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.RedirMax

Specifies the maximum allowable value of the redirection counter parameter available in some C7 signaling systems before the call is force-released. Used to prevent routing loops in certain applications.

Default: 5

Value range prior to Release 9.7(3) S22P22: 0 to system maximum.Value range for Release 9.7(3) S22P22 and later:

1-5:

OCC—Allow the specified number (1-5) of redirections before the call is force-released.

TCC—Reset the redirect counter to 5 if it is < 1 or > 5.

0:

OCC—Allow the redirection counter to have any value from 1 to 7.

TCC—If the redirection counter is set to a value 0-7, set it as is; if the redirection counter is greater than 7, reset it to 7.

OCC = Originating (side) call control.
TCC = Terminating (side) call control.

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.RedirNumFor
Analysis

This is an integer that indicates whether the Cisco PGW 2200 Softswitch performs number analysis based on redirecting number (where applicable).

Valid values:

0—Do not use the redirecting number for number analysis.

1—Use the redirecting number for number analysis without support of redirecting number modification (RMODDIG disabled).

2—Use the redirecting number for number analysis with support of redirecting number modification (RMODDIG enabled).

3-Use the redirecting number for number analysis no matter with or without support of redirecting number modification(both AMODDIG and RMODDIG enabled)

Default value: 0

EISUP

SIP

EISUP

SIP

*.ReferRedirectingInd

Redirecting indicator of Redirection Information in ITU SS7 REL message for blind transfer by SIP REFER.

Value range:

0—No redirection

1—Call rerouted

2—Call rerouted, all redirection information presentation restricted

3—Call diverted

4—Call diverted, all redirection information presentation restricted

5—Call rerouted, redirection number presentation restricted

6—Call diversion, redirection number presentation restricted

SIP

SS7-ITU

TRUNKGROUP

*.ReferRedirectingNOA

NOA value of redirection number in ITU SS7 REL message for blind transfer by sip REFER. Use internal NOA value.

Value range:

1—NOA_NONE

2—NOA_UNKNOWN

3—NOA_SUBSCRIBER

4—NOA_NATIONAL

5—NOA_INTERNATIONAL

TRUNKGROUP

TRUNKGROUP

*.ReleaseMode

Defines the type of releasing. Asynchronous clearing allows both OCC and TCC sides to clear independently; circuits are freed earlier in the release sequence. Synchronous clearing requires that the clearing at the two sides is synchronized.

Note There may be times when synchronous clearing is more appropriate for a Cisco PGW 2200 Softswitch configuration, for example, when supplementary service signaling contained in clearing messages requires transporting between the two sides.

Valid values: Async or Sync. If migrating from a previous software version, async, ASYNC, sync, and SYNC are also valid values. (This property value is determined by the engine.SysVirtualSwitch parameter setting.)

Default: Async

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.respectSipUriU
serParm

Allows the Cisco PGW 2200 Softswitch to ignore the p-asserted-id and remote-party-id headers if user=phone value is not present.

Valid values:

0—The Cisco PGW 2200 Softswitch always processes the p-asserted-id and remote-party-id headers.

1—The Cisco PGW 2200 Softswitch ignores the p-asserted-id and remote-party-id headers if the user=phone value is not present.

Default value: 0

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Response
Attempts

Defines the transmission times for response.

Valid Values: integer (1-15)

Default Value: 11

Dynamically Reconfigurable: y

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.restartTimer

Time (in tenths of a second) to pause before sending next group of messages to MTP3 after restart. Value range: 0 through 100, where 0 = Disabled and 10 = 1 second.

Default: 10

SS7-ANSI

SS7-ANSI

*.RestrictPresIfNoPAID

This property indicates whether the Cisco PGW 2200 Softswitch sets the CgPN Address Presentation Restricted Identifier (APRI) of the outgoing ISUP message to presentation restricted when the incoming SIP-I message does not contain the P-Asserted-Identity header. This property is for PSTN emulation services (SIP/SIP-I).

Valid values: boolean

0 = If the incoming SIP-I message does not contain the P-Asserted-Identity header, the Cisco PGW 2200 Softswitch sets the CgPN APRI of the outgoing ISUP message according to the ITU-T Recommendation Q1912.5.

1 = If the incoming SIP-I message does not contain the P-Asserted-Identity header, the Cisco PGW 2200 Softswitch sets the CgPN APRI of the outgoing ISUP message to presentation restricted.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.RetransMethod

Defines the re-transmission method.

Valid Values:

1 = exponential

2 = linear

Default Value: 1

Dynamically Reconfigurable: yes

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.RetryAfterTimer

Maps to trunk group property RetryAfterTimer. Indicates the time (in milliseconds) the Cisco PGW 2200 Softswitch waits before successfully retrying a SIP call. Value range: any value greater than 0.

Default: 90000

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.RingNoAnswer

Ring no answer. Indicates the time, in seconds, ringing is allowed to occur. Value range: 0 through 600.

Default: 255

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.RltPrefixLength

Length of the prefix to be removed from the RLT redirection number before the number is sent to ISUP side. Valid value must be larger than 0. Value of 0 means no redirection number manipulation is enabled. If the value is larger than or equal to the total length of the redirection number, Cisco PGW 2200 Softswitch automatically ignores this configuration.

Value Range: 0-255.

Default value: 0.

This property is added in Release 9.8(1) S9P9.

TRUNKGROUP

*.rnInclude

Indicates whether or not to include the Redirecting Number in an IAM. Values: 0 (for no) or 1 (for yes).

Default:0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.RORequestDelayTimer

Specifies the time delay before sending out Route Optimization requests.

Valid Values: Integer, range 0-1000

Default value: 0

DPNSS

DPNSS

*.RouteId

This property is needed so that the user/customer can specify a route ID to overwrite the ID received in the RIN parameter in the IAM from the OCC side. Value range: 0 through 65355.

Default: 0

SS7-ITU

SS7-ITU

*.RoutePref

Determines the preferred route. Value range: 0 through 9.

0 = No Preference (default) 5 = IP Preferred

1 = ATM Essential 6 = IP Excluded

2 = ATM Preferred 7 = TDM Essential

3 = ATM Excluded 8 = TDM Preferred

4 = IP Essential 9 = TDM Excluded

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.rudpNumRetx

The maximum number of RUDP retransmissions count.
Value range: 1 through 100.

Default: 2

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SESSION

*.rudpRetxTimer

The retransmission timeout. Value range: 2 through 100.

Default: 6

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SESSION

*.rudpWindowSz

The maximum number of unacknowledged segments in the RUDP window. Value range: 2 through 64.

Default: 32

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SESSION

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

SESSION

*.SatelliteInd

Satellite indicator. Indicates if the trunk is going over a satellite. Values are: 0 (no) or 1 (yes).

Default: 0

TRUNKGROUP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

SESSION

*.ScreenFailAction

Screen fail action. Indicates if an action is to be performed when a screening failure occurs. Values are: 0 (no) or 1 (reject call).

Default: 0

TRUNKGROUP

TRUNKGROUP

COMMONPROFILE

*.SdpXmitToH323Trigger

Indicates the point in a call when the Cisco PGW 2200 Softswitch sends the Session Destination Protocol (SDP) from the terminating call leg to the H.323 Signaling Interface (HSI).

Value range: 0 through 4. 0 = terminating seizure, 1 = Address complete, 2 = Alerting or Inband information available, or 3 = Answer. 4 =ACM with interworking or inbandinfo or ISDN not all the way

Default: 0

This property is added in software Release 9.4(1).

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

*.SendAddressIn
Cgpn

Determines if the CLI digits are sent in the outgoing calling party number parameter. Value is: 0 (False) for do not include address digits in calling party number parameter, or 1 (True) for including address digits in calling party number parameter.

Default: 1

SS7-ANSI

SS7-ITU

SS7-UK

TRUNKGROUP

SS7-ANSI

SS7-ITU

SS7-UK

TRUNKGROUP

COMMONPROFILE

*.sendAfterRestart

Number of queued messages to send (in one group) to MTP3 after restart end. This value, combined with the sendTimer, controls the amount of data sent to MTP3 after restart ends. If too much data is sent to MTP3 after restart, MTP3 could be flooded. Value range: 0 through 256.

Default: 16

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.SendDtmfBeforeConnect

Determines if the DTMF signal is sent out to the terminating call side before the connection is set up. Value is: 0 for the DTMF to be sent to the TCC only after the connection is set up, or 1 for the DTMF to be sent to the TCC after the ACM is received.

Default:0

This property is added in software Release 9.6(1).

EISUP

EISUP

*.serviceCode
Include

Indicates whether or not to include the Service Code parameter in an IAM. Values are: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.sgcpRetxCount

Number of times an SGCP msg is retried upon failure. Value range: 1 to 4.

Default: 3

SGCP

SGCP

*.sgcpRetxTimer

Timer interval in milliseconds, between invocations of the SGCP retry timer. Value range: 0 to 3000.

Default: 1000

SGCP

SGCP

*.SipCallHold
Method

Indicates which call hold method the Cisco PGW 2200 Softswitch uses. Cisco PGW 2200 Softswitch has two SIP call hold methods. One is according to RFC2543, setting c=0.0.0.0, the other is according to RFC3264, setting a=sendonly or a=inactive. Both are supported, but when Cisco PGW 2200 Softswitch initiates call hold, there must be a rule to follow. This provision determines how Cisco PGW 2200 Softswitch handles a received call hold request from the ISUP/HSI side, but if an RFC2543 call hold request is received before Cisco PGW 2200 Softswitch sends a call hold request, Cisco PGW 2200 Softswitch sets itself in RFC2543 call hold method even if it is configured to RFC3264. If an RFC3264 call hold request is received before Cisco PGW 2200 Softswitch sends a call hold request, Cisco PGW 2200 Softswitch sets itself in RFC3264 call hold method even if it is configured to RFC2543.

Valid Values:

0 (RFC3264 method: "a=sendonly")

1 (RFC2543 method: "c=0.0.0.0")

Default Value: 0

Property Domain: _X_SigPath

Protocol Family: SIP

Dynamically Reconfigurable: yes

SIP

SIP

*.SIPCOLPReq
Enabled

This property specifies whether the COLP request for SIP-originated calls is enabled or not. This property is for PSTN emulation services (SIP/SIP-I).

Values: boolean (0 = not enabled, 1 = enabled).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

*.SipDtmfContentType

This property determines the Content-Type header and the SDP content of INFO requests Cisco PGW 2200 Softswitch sends.

Valid values:

0 = Sets the Content-Type header to audio/telephone-event

1 = Sets the Content-Type header to application/dtmf-relay

Default value: 0

SIP

TRUNKGROUP

SIP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipEgressEarly
DialogRelType

This property indicates whether the Cisco PGW 2200 Softswitch sends the CANCEL message or the BYE message for the Early Dialog release. This property is for Q.1912.5 compliance.

Valid values: boolean (0 = send the CANCEL message, 1 = send the BYE message).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipEgressGN2
FromScreenInd

This property controls how the Cisco PGW 2200 Softswitch maps the generic number to the SIP From header. This property is for PSTN emulation services (SIP/SIP-I).

Valid values: integer (from 0 to 3)

0 = UPVP and UPNV—If the screen indicator sub-parameter in the incoming ISUP message is UPVP or UPNV and the property value is 0, the Cisco PGW 2200 Softswitch maps the generic number to the SIP From header.

1 = UPVP—If the screen indicator sub-parameter in the incoming ISUP message is UPVP and the property value is 1, the Cisco PGW 2200 Softswitch maps the generic number to the SIP From header.

2 = UPNV—If the screen indicator sub-parameter in the incoming ISUP message is UPNV and the property value is 2, the Cisco PGW 2200 Softswitch maps the generic number to the SIP From header.

3 = always mapping—If the property value is 3, the Cisco PGW 2200 Softswitch always maps the generic number to the SIP From header.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.sipEgress
RoutingControl

Defines the preferred SIP header used for egress routing decisions, based on the initial SIP INVITE message.

Valid Values:

1 = Allow Request-Line Modification (strict router behavior)

The Cisco PGW 2200 Softswitch modifies the SIP header with routing changes and ignores any pre-existing routes. The Cisco PGW 2200 Softswitch does not include an explicit route in the initial INVITE message.

2 = Allow Request-Line Modification

The Cisco PGW 2200 Softswitch handles egress routing as follows:

The Cisco PGW 2200 Softswitch removes the first route in any pre-existing route set (after removal of any Route: matching the Cisco PGW 2200 Softswitch Domain) and uses it in the Request-Line, if present.

If further routes exist, the Cisco PGW 2200 Softswitch forwards the remaining routes. If the Cisco PGW 2200 Softswitch did not receive additional routes, it uses the analysis routing changes in the request-line.

3 = Protect Request-Line URI

The Cisco PGW 2200 Softswitch inserts an explicit Route: header into the route set if the routing is different from the Request-Line. This setting requires that the next hop device act as a loose router.

4 = Protect Request-Line URI

The Cisco PGW 2200 Softswitch removes all existing Route: Headers and inserts an explicit Route: header if routing is different from the Request-Line. This setting requires that the next hop device act as a loose router.

TRUNKGROUP

SIP

*.sipEgress
RoutingControl

5 = Protect Request-Line URI

The Cisco PGW 2200 Softswitch handles egress routing as follows:

If a pre-existing route set exists, the Cisco PGW 2200 Softswitch removes the first route if it matches the Cisco PGW 2200 Softswitch's Domain, and forwards the headers of any existing routes. The Cisco PGW 2200 Softswitch discards any routing changes encountered during analysis, honoring trunk group selection only.

If no route-set exists but analysis has changed routing, the Cisco PGW 2200 Softswitch inserts an explicit route, leaving the request-line unchanged.

Default: 1

Note If the sipRoutingMode XECfgParm parameter is set to 0 (strict-router), sipEgressRoutingControl must be set to 1.

TRUNKGROUP

SIP

*.SipICANCEL
EncapREL

This property indicates whether the encapsulated REL message is required or not in the CANCEL message.

This property is a non-essential SIP-I-specific property.

Valid values: boolean (0 = not required, 1 = required).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipICLICOL
Preference

This property indicates which parameters the CLI/Connect number takes as preference, SIP header or ISUP parameters. This property is a non-essential SIP-I-specific property.

Valid values: boolean.

0 = CLI/Connect number takes SIP header parameters as preference.

1 = CLI/Connect number takes ISUP parameters as preference.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIConfusion
Handling

This property indicates whether to terminate the ISUP confusion message or transport this message transparently. This property is a non-essential SIP-I-specific property.

Valid value: boolean.

0 = terminate the ISUP confusion message.

1 = transport the ISUP confusion message transparently.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIEgress
Handling

This property indicates the value of handling the disposition parameter in the Content-Disposition header field of the ISUP MIME body in SIP-I messages. This property is set on outgoing trunk groups with SIP-I support. If it is set to 2, "handling=required" is always added to the INVITE Content-Disposition header. If it is set to 0, "handling=required" is added only if there is a to-be-encapsulated IAM message with user-to-user information; otherwise, "handling=optional" is added. This property is an essential SIP-I-specific property.

Valid value: integer (from 0 to 2)

0 = Content-Disposition header is "Content-Disposition:signal; handling=required" only if there is a to-be-encapsulated IAM message with user-to-user information; otherwise, Content-Disposition header is "Content-Disposition:signal; handling=optional".

1 = Content-Disposition header is "Content-Disposition:signal; handling=optional".

2 = Content-Disposition header is "Content-Disposition:signal; handling=required".

Default value: 1.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIEgressISUPVersion

This property indicates the version sub-parameter used in the Content-Type header field for SIP-I messages on the outgoing SIP trunk group. This property is an essential SIP-I-specific property.

Valid values: NULL or any string up to 128 characters in length.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIEgressMDO

This property indicates the SIP-I variant name on the outgoing SIP trunk group. This property is an essential SIP-I-specific property.

Valid values: NULL or any string up to 40 alphanumeric characters.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIFacility
RejectHandling

This property indicates whether to terminate the ISUP facility reject message or transport this message transparently. This property is a non-essential SIP-I-specific property.

Valid values: boolean.

0 = terminate the ISUP facility reject message.

1 = transport the ISUP facility reject message transparently.

Default value: 0

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIIngress
VersionMAP

This property indicates the SIP-I mapping profile name which is defined in the SIP profile name field of the sipIVersion.dat file. This property is an essential SIP-I-specific property.

Valid values: NULL or the string defined in the SIP-I mapping profile name field of the sipIVersion.dat file, like BT.

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIngressLNP
Handling

This property controls whether the Cisco PGW 2200 Softswitch maps the SIP routing number and the telephone number to the called party number and the generic address ISUP parameters. This property is for PSTN emulation services (SIP/SIP-I).

Valid values: boolean (0 = no mapping, 1 = mapping)

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.sipIngress
RoutingControl

Defines the preferred SIP header used for ingress routing decisions as determined from the initial INVITE message.

Valid Values:

1 = Explicit Route header

2 = Request Line

3 = To: header

Default Value: 2

Note If the sipRoutingMode XECfgParm parameter is set to 0 (strict-router), only option 2 is valid.

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipInsertReasonHeader

This property indicates whether a reason header containing the cause code is required or not. This property is for Q.1912.5 compliance.

Valid values: integer (from 0 to 2)

0 = do not insert the reason header.

1 = add the reason header in Q.850 format.

2 = add the reason header in ANSI format.

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIPSource

Indicates for the Cisco PGW 2200 Softswitch to use the IP packet source address or IP address from Session Description Protocol (SDP) in the INVITE message to make the dial plan selection for SIP calls. Valid values: 0 (use the IP packet source address) or 1 (use the IP address from SDP).

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipIToiw2

This property indicates the Toiw2 timer value measured in seconds. This property is for Q.1912.5 compliance.

Valid values: integer (from 4 to 14).

Cause for initiation: Sending of INVITE.

Termination criterion: On receipt of 18x, or 200 OK INVITE.

Action At expiry: Send early ACM

Default value: 4.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.sipMimeBody
Support

This property indicates how SIP, SIP-T, SIP-GTD, and SIP-I are supported on a trunk group. Valid values:

0 = only SIP supported

1 = SIP-T supported

2 = SIP-GTD supported

3 = Only SIP-I is supported on the incoming trunk group. SIP and SIP-I are supported on the outgoing trunk group

4 = SIP and SIP-I are supported on both the incoming and outgoing trunk groups

Default: 0

Note For Release 9.7, if you set sipMimeBodySupport to 2 on originating side, the Cisco PGW 2200 Softswitch does not check the value of sipMimeBodySupport on terminating side. It will transit incoming SIP-GTD messages recived from originating call control (OCC) to terminating call control (TCC).
For Release 9.8, if you set SipMimeBodySupport to 2 on terminating side, the Cisco PGW 2200 Softswitch will use CC container to build the outgoing SIP-GTD messages. If SipMimeBodySupport is NOT set to 2, the Cisco PGW 2200 Softswitch will send out SIP messages, not SIP-GTD messages.

This property is added in software Release 9.4(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipRedir
AnalysisMethod

Specifies whether the Cisco PGW 2200 Softswitch performs B-number analysis on the number returned in a 302 contact. This property is useful if a redirect returns a contact that the Cisco PGW 2200 Softswitch cannot analyze.

Valid values:

0 = If the host listed in the 302 contact is the Cisco PGW 2200 Softswitch host, perform digit analysis. (conditional)

1 = The Cisco PGW 2200 Softswitch does not perform digit analysis on the called party number (B number).

2 = The Cisco PGW 2200 Softswitch does not perform digit analysis on the calling party number (B number).

SIP

SIP

*.SipReferFor
SingleStepXfer

Enables/disables special handling for SIP REFER, which is required to support the single-step call transfer (SSCT) supplementary service. This property is used for SIP signaling services when supporting communication with a VoIP gateway connected to a QSIG PBX. Valid values: 0 (Standard SIP REFER) or 1 (SIP REFER to support SSCT).

Default: 0

This property is added in software Release 9.5(2).

SIP

SIP

*.SipSatelliteInd
Enable

This property is added in software Release 9.7(3) S5P5

Specifies whether to set the satellite_circuit_in_connection indicator to 1 in the IAM for SIP to SS7 calls. (According to ITU-T Recommendation Q.1912.5, Table 4, Satellite Indicator should be set to 1 for SIP to SS7 calls.)

This property allows you to set the satellite_circuit_in_connection indicator to 0 or 1 according to your specific requirements.

Valid values: 0, 1

Default value: 1

SIP

SIP

*.SipTgrpLabel

Use this property to specify the clear channel routing class in SIP signaling. When you set the CheckSipTgrpParam property to 1, the value of the tgrp parameter in the first incoming SIP INVITE message must match this property value. This property is provisioned in SIP profiles.

Valid values: string (1 to 64 bytes string) or NULL (does not check the tgrp parameter).

Default value: ccdata.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipToIsupRatio

Set the ratio of Max_Forwards to Hop Counter for a call from SIP to ISUP.

Valid values: 0 through 4. 0 indicates the mapping does not function.

Default value: 0

SIP

SIP

*.siptransportmode

Specifies the transport protocol permitted for a trunk group.

Valid values:

0 = UDP

1 = TCP

2 = DYNAMIC

Default value: 0

Dynamically reconfigurable: Yes

Note This property can be overridded based on values provisioned for the *.SipUDP2TCPByteXover property.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipTrunkContext

Use this property to specify a namespace on the trunk group. When you set the CheckSipTgrpParam property to 1, the value of the trunk-context parameter in the first incoming SIP INVITE message must match this property value. This property is provisioned in SIP profiles.

Valid values: string (1 to 64 bytes) or NULL (does not check the trunk-context parameter).

Default value: NULL.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipUPDATESupport

Associate this SIP profile property with a SIP trunk group. This property indicates whether or not the Cisco PGW 2200 inserts the UPDATE method into the ALLOW header during initial dialog exchanges preliminary to establishing a call. If you set this property to 1 (the default), the system inserts the UPDATE method into the ALLOW header. If you set this property to 0, the system does not insert the UPDATE method into the ALLOW header.

When the dialog advances to an exchange of 200 OK messages, this property setting is no longer a factor in the exchange of call signaling messages.

Valid values: 0 and 1

0—Do not insert the UPDATE method in the ALLOW header

1—Insert the UPDATE method in the ALLOW header

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SipUDP2TCP
ByteXover

Determines the SIP message size (in bytes) above which the Cisco PGW 2200 Softswitch switches to TCP transport. This property applies to outgoing SIP traffic only.

Valid values:

0—The Cisco PGW 2200 Softswitch does not switch from UDP to TCP regardless of the SIP message size.

1-10000—The Cisco PGW 2200 Softswitch switches to TCP transport for messages above the specified size (in bytes).

Default value: 0

Note This property overrides the siptransportmode parameter.

This property is added in software Release 9.8(1).

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.slsTimer

Time (in tenths of a second) to maintain the same signal linkset in class 1 (connectionless) messages. This is the type of service provided by the SCCP layer. Value range: 0 through 600, where 0 = Disabled and 300 = 30 seconds.

Default: 300

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.spanId

E1/T1 ID for FAS and DPNSS, ffff for SS7. Value range: Hex 0 through ffff.

Default: ffff

DPNSS

ISDNPRI

DPNSS

ISDNPRI (BRI)

*.srcpAuditGw
Interval

Indicates how often the SRCP protocol should perform a GW audit on the gateway, in seconds. Value range: 0 through 1000.

Default: 10

MGCP

MGCP

*.srcpAuditLine
Interval

Indicates how often the SRCP protocol should perform a line audit on the gateway, in seconds. Value range: 0 through 1000.

Default: 10

MGCP

MGCP

*.srcpHeartbeat
Interval

Indicates how often the SRCP protocol should heartbeat the gateway, in seconds. Value range: 0 to 1000.

Default: 10

MGCP

MGCP

*.srcpIpPortLocal

Local IP port to which the SRCP protocol should bind to receive messages from the gateway. Setting this value to zero turns off srcp.

Default: 0

MGCP

MGCP

*.srcpIpPort
Remote

Remote IP port to which the SRCP protocol should send messages.

Default: 2428

MGCP

MGCP

*.srcpRemote
AuditGwInterval

Indicates how often the SRCP protocol should perform an audit on remote gateway, in seconds. Value range: 0 through 1000.

Default: 10

MGCP

MGCP

*.srcpRetxCount

A limit on the number of retransmissions before declaring failure. Value range: 0 through 10.

Default: 3

MGCP

MGCP

*.srcpRetxTimer

A limit on the time to wait for a response from a gateway before retransmitting the message, in milliseconds. Value range: 0 through 60000.

Default: 1000

MGCP

MGCP

*.sRtpAllowed

This property controls whether the trunk group supports SRTP or not. This property is provisioned as either a trunk group property or a SIP profile property.

Valid values: boolean (0 = does not support, 1 = supports).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1)

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.sRtpSupported

This property indicates whether a media gateway supports SRTP or not. This property is provisioned on an MGCP sigPath.

Valid values: boolean (0 = does not support, 1 = supports).

Default value: 0.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1)

MGCP

*.srtTimer

Time (in tenths of a second) between sending Subsystem Route Test message (SRT) to remote subsystems. Value range: 0 through 3000, where 0 = disabled and 300 = 30 seconds.

Default: 300

SS7-ANSI

SS7-ANSI

*.SSCTInvoke
TimerT1

A millisecond timer, as specified by ROSE, that is used to invoke the single-step call transfer (SSCT) supplementary service. This property is used for communication with a VoIP gateway connected to a QSIG PBX. Valid values: from 50000 to 180000 (in milliseconds)

Default Value: 50000

This property is added in software Release 9.5(2).

ISDNPRI

ISDNPRI (BRI)

*.sstTimer

Time (in tenths of a second) between sending Subsystem Route Test message (SRT) to remote subsystems. Value range: 0 through 3000, where 0 = disabled and 300 = 30 seconds.

Default: 300

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.standard

Version of protocol standard supported for this STP/SCP.

Defaults: SS7-ANSI = ANSI96,
SS7-ITU = ITU96,

ANSI96,
ITU96,
ANSI92,
ITU92

SS7-ANSI

SS7-ITU

SS7-ANSI

SS7-ITU

*.STdigitforCDPN

Specifies whether a stop digit is applied to the called party number during call processing. This property was introduced in Cisco PGW 2200 Softswitch version 9.6(1).

Note This property applies to Q.767 only.

Values:

0 = Stop digit applied to IAM and SAM

If the Cisco PGW 2200 Softswitch is in en bloc mode, it applies the stop digit to the called party number in the IAM (Initial Address Message). If the Cisco PGW 2200 Softswitch is in overlap mode, it applies the stop digit to the called party number in the SAM (Subsequent Address Message).

1 = Stop digit applied to SAM only

If the Cisco PGW 2200 Softswitch is in en bloc mode, it does not apply the stop digit to the calling party number in the IAM (Initial Address Message). If the Cisco PGW 2200 Softswitch is in overlap mode, it applies the stop digit to the called party number in the SAM (Subsequent Address Message).

2 = Stop digit not applied to IAM or SAM

The Cisco PGW 2200 Softswitch does not apply the stop digit to the called party number in either the IAM (Initial Address Message) or the SAM (Subsequent Address Message), regardless of whether the Cisco PGW 2200 Softswitch is in en bloc or overlap mode.

Default: 0

TRUNKGROUP

SS7-ITU

*.STdigitforCLI

Indicates during call processing whether or not a stop digit is applied to the calling number. Values: 0 (no stop digit is applied to the calling number) or 1 (a stop digit is applied to the calling number and the Calling Line Identity parameter D bit is set to 0 specifying "No Indication").

Note Only valid for Q721_CHINA.

Default: 0

SS7-China

SS7-China

*.SubscribeNotifySupport

Determines if the SIP Subscribe/Notify methods for solicited notification of SIP DTMF digits is enabled or disabled.

Valid Values:

0 = Subscribe/Notify methods disabled

1 = Subscribe/Notify methods enabled

Default: 0

This property is added in software Release 9.4(1).

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.Support183

Maps to trunk group property Support183. Indicates how the Cisco PGW 2200 Softswitch supports 183 response code. This property is for Q.1912.5 compliance.

Valid values: integer (from 0 to 5).

0 = 183 not supported

1 = Q1912.5 supported without SDP in 180 message

2 = Q1912.5 supported with InbandInfo check

3 = 183 supported

4 = always send 183

5 = Q1912.5 supported

Default value: 3.

Dynamically reconfigurable: yes.

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.supportKPML

SIP profile property. Indicates whether the Cisco PGW 2200 Softswitch relays or ignores the KPML information received in SIP message on the ingress SIP Trunk. Also, indicates whether KPML information received from ingress trunk shall be relayed or ignored on the egress SIP trunk.

Valid values:

0—KPML information is relayed

1—KPML information is ignored

Default value: 0.

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SupportReliable
100

Maps to trunk group property SupportReliable100. Indicates if the Cisco PGW 2200 Softswitch supports reliable100 response code. Values are: TRUE or FALSE.

Default: FALSE

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SupportTelURIinPAID

SIP profile property. Indicates whether the Cisco PGW 2200 Softswitch supports tel URI in PAID header. When the SupportTelURIinPAID property is set to 0 on the sip profile, the PAID will not be passed in the IAM as CLI. When this property is set to 1 on the sip profile, the PAID information will be passed in the IAM as CLI.

Valid values:

0—Disable.

1—Enable.

Default value: 0.

This property is added in software Release 9.8(1) S10P10.

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.SuppressCHGN
toCGPNMapping

Suppresses charge number-to-calling party number mapping in the outgoing SETUP message, when no calling party number is supplied on the incoming call side. Values are:

0—If there is no calling party number in the incoming IAM message, the charge number (if available) is mapped into the calling party number in the outgoing SETUP message.

1—If there is no calling party number in the incoming message, no calling party number is included in the outgoing SETUP message (that is, the charge number-to-calling party number mapping is suppressed).

Default: 0

ISDNPRI

ISDNPRI (BRI)

*.SuppressCLI
Digits

Suppresses the calling party number. Values are: 0 (do not suppress but leave the calling number intact) or 1 (remove calling party number so no number is forwarded).

Default: 0 (do not suppress)

DPNSS

EISUP

ISDNPRI

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SS7-ITU

SS7-Japan

SS7-UK

COMMONPROFILE

*.SwitchID

The switch number for the Cisco PGW 2200 Softswitch.

Default: 0

SS7-ANSI

SS7-ANSI

*.T309Time

For timer NT309. In pri_10.mdl. Value range: 6000 through 900000, in milliseconds.

Default: 90000

MGCP

DPNSS

ISDNPRI (BRI)

*.T310Time

For timer 310, which is started when the Call Proceeding message is received by the Cisco PGW 2200 Softswitch and is stopped when the Alerting, Progress, Connect, or Disconnect messages are received. Value range: 3000 through 120000, in milliseconds.

Default: 10000

MGCP

DPNSS

ISDNPRI (BRI)

*.T_CCR

Timer for continuity check request.

SS7-ANSI

SS7-ANSI

*.T_CCRR

Timer for continuity check recheck request.

SS7-ANSI

SS7-ANSI

*.T_CGB

Wait timer for circuit group block message.

SS7-ANSI

SS7-ANSI

*.T_CGBA

Wait timer for circuit group block ACK message.

SS7-ANSI

SS7-ANSI

*.T_CRA

Timer for circuit reservation acknowledgment.

SS7-ANSI

SS7-ANSI

*.T_CVT

Timer for circuit validation test. Default: 0 (milliseconds).

SS7-ANSI

SS7-ANSI

*.T_GRS

Wait timer for circuit group reset message.

SS7-ANSI

SS7-ANSI

*.Ta1TimePeriod

Time period, in seconds, before credit expiry that the SCP is notified. Value range: 1 through 180.

Default: 20

SS7-ITU

SS7-ITU

TRUNKGROUP

COMONPROFILE

*.Ta2TimePeriod

Time period, in seconds, before credit expiry that a warning tone or announcement is played. Value range: 1 through 180.

Default: 30

SS7-ITU

SS7-ITU

TRUNKGROUP

COMONPROFILE

*.Ta3TimePeriod

Time period, in seconds, before credit expiry that the Cisco PGW 2200 Softswitch awaits an SCP response. Value range: 1 through 180.

Default: 3

SS7-ITU

SS7-ITU

TRUNKGROUP

COMONPROFILE

*.TBufferDigit
Length

Limits the maximum number of digits allowed in the outgoing IAM and SAM.

Valid Values: 0 through 32. 0 disables the feature.

Default Value: 0

SS7-China

SS7-ITU

SS7-UK

SS7-China

SS7-ITU

SS7-UK

COMMONPROFILE

*.TimeOutCBNU

Sets the timer out value for Call Back When Not Used against the CTI sigpath, in minutes. Value range: 100 through 1500.

Default: 100

This property is added in software Release 9.6(1).

CTI-QBE

CTI-QBE

*.TimeOutCBWF

Sets the timer out value for Call Back When Free again the CTI sigpath, in minutes. Value range: 100 through 1500.

Default: 100

This property is added in software Release 9.6(1).

CTI-QBE

CTI-QBE

*.TlinkAlignTime

Configurable timer for all Q.761, Q.767, and ANSI protocols. Value range: 0 (disables the timer) to n (in milliseconds).

Default: 0

SS7-ANSI

SS7-ITU

SS7-UK

EISUP

SIP

SS7-ANSI

SS7-ITU

SS7-UK

COMMONPROFILE

*.TMaxDigits

Specifies maximum number of digits to receive for overlap digit processing for call termination to this traffic path. Value range: 0 through system maximum.

Default: 24

DPNSS

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.TMinDigits

Specifies minimum number of digits to receive for overlap digit processing for call termination to this traffic path. Value range: 0 through system maximum.

Default: 0

DPNSS

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

SIP

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.ToneOption

Specifies whether playing a tone to the originating side is mandatory. This applies only to an ingress IP trunk group.

Valid values:

0—Playing a tone is optional.

1—Playing a tone is mandatory.

Default: 0

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.topologyHiding
Enabled

Indicates whether topology hiding is enabled.

Valid values:

0 = Trust level configuration

1 = Disabled

2 = Enabled

Default value: 1

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

*.TOverlap

Set to 1 to enable overlap signaling for call termination to this traffic path. Values are: 0 or 1.

Default: 0

DPNSS

EISUP

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

EISUP

ISDNPRI (BRI)

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

*.TransferAwait
Connect

Await connection flag, which is used to determine when a QSIG PBX releases a call. This property is used for communication with a VoIP gateway connected to a QSIG PBX, when the implementation of MWI on the PBX deviates from the ECMA standard. Valid values: 0—(false) QSIG PBX releases original call after receiving ALERT, or 1—(true) QSIG PBX releases original call after receiving CONNECT).

Default: NULL

This property is added in software Release 9.5(2).

ISDNPRI

ISDNPRI (BRI)

*.transReqInclude

Indicates whether or not to include the Transaction request parameter in an IAM. Values: 0 (for no) or 1 (for yes).

Default: 0

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.TrunkGroupTag
Label

This property identifies name of the trunk group from which a call comes.

Value: String from 1-63 characters

Default: Null

Dynamically Reconfigurable: Yes

Note This property does not support some special characters like #, >, and white space. MML does not permit provisioning these characters to the TrunkGroupTagLabel.

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.TrunkGrpTag
LabelTransEnable

Indicates how the Cisco PGW 2200 Softswitch handles the ingress trunk group tag label (if present) in the outgoing SIP INVITE message. This property is dynamically reconfigurable.

Values:

0: The Cisco PGW 2200 Softswitch does not send the ingress trunk group tag label

1: The Cisco PGW 2200 Softswitch sends the ingress trunk group tag label in the x-route-tag parameter

2: The Cisco PGW 2200 Softswitch sends the ingress trunk group tag label in the tsp parameter

Default: 0

Dynamically Reconfigurable: Yes

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.trustLevel

Indicates if the trunk group or domain is on a trusted or non-trusted interface.

Valid values:

0 = trusted

1 = non-trusted

Default value: 1

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

DOMAINPROFILE

*.unavailProc

Indicates the procedure to follow when there are no available ISUP circuits. Values are: ALTRTE (alternate routing) or BLO (blocking).

Default: ALTRTE

SS7-ANSI

TRUNKGROUP

SS7-ANSI

COMMONPROFILE

GRPROFILE

*.Unsolicited
NotifyMethod

Determines if the unsolicited Notify method for unsolicited notification of SIP DTMF digits is enabled or disabled.

Valid Values:

0 = Unsolicited Notify method disabled

1 = Unsolicited Notify method enabled

2 = Unsolicited Info method enabled

Default: 0

SIP

TRUNKGROUP

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.useDomain
Profile

Indicate whether domain profiles are enabled for a SIP profile.

Valid values:

0 = Disabled

1 = Enabled

Default value: 0

Dynamically reconfigurable: Yes

This property is added in software Release 9.8(1).

SIPPROFILE

UseGtdCalledPartyNumber

Enables PGW to use embedded calledPartyNumber field of GTD in the invite message instead of url/number contained in the request line. Valid values: 0—disable, 1—enable.

TRUNKGROUP

SIPPROFILE

*.variant

SS7 protocol variants supported by local subsystem.

Default: SS7-ANSI

Note This property is used only if the profile type is ISUPTMRPROFILE.

SS7-ANSI

SS7-ANSI

*.VideoAllowed

You use this property to specify whether the Cisco PGW 2200 Softswitch allows video calls on SIP or EISUP trunk groups.

Valid values: boolean (0 = video calls not allowed, 1 = video calls allowed).

Default value: 1.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.VOIPPrefix

A numeric string.

Default: 0

DPNSS

ISDNPRI

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

DPNSS

ISDNPRI (BRI)

SS7-ANSI

SS7-China

SS7-ITU

SS7-Japan

SS7-UK

*.WaitAnswer
Timer

Wait for Answer Timer. The timer is started when the Cisco PGW 2200 Softswitch instructs the MGW to apply ring back tone upon receiving Alerting. The timer is stopped when the Cisco PGW 2200 Softswitch receives the Answer message. Value range: 0 through 300 (in seconds).

Default: 65

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.WaitOrigSDP
Timer

Wait for Originating SDP Timer. On H.323 originated calls, the Cisco PGW 2200 Softswitch transits the answer message and starts this timer when the originating SDP information has not been received. Value range: 0 through 50 (in seconds).

Default: 10

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.WaitTermSDP
Timer

Wait for Terminating SDP Timer. On H.323 terminated calls, the Cisco PGW 2200 Softswitch transits the answer message and starts this timer when the terminating SDP information has not been received. Value range: 0 through 50 (in seconds).

Default: 10

TRUNKGROUP

TRUNKGROUP

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

*.XmitCalling
Name

Allows the Cisco PGW 2200 Softswitch to use the displayname in the INVITE or INFO header for the calling party name.

Valid values:

0 = The Cisco PGW 2200 Softswitch does not retrieve the displayname.

1 = The Cisco PGW 2200 Softswitch retrieves the displayname from the RemotePartyID Header.

Default: 0

SIP

TRUNKGROUP

SIP

TRUNKGROUP

*.ZoneID

Specifies the administrative zone that a trunk group belongs to. The wildcard, *, is supported as the zone ID. If the property value is set to * for a trunk group, the zone ID of this trunk group matches any zone ID set on other trunk groups. This property can be provisioned in a SIP or EISUP profile, or a domain profile.

Valid values: string (1 to 63 characters) or none.

Default value: none.

Dynamically reconfigurable: yes.

This property is added in software Release 9.8(1).

EISUPPROFILE

SIPPROFILE

COMMONPROFILE

DOMAINPROFILE

SS7-ANSI.cong
Proc

Indicates the procedure to follow when there is congestion on ISUP circuits. This value is taken from the originating trunk group and is used in call control when re-attempting occurs. Values: ALTRTE (alternate routing) or BLK (blocking).

Default: BLK

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
ApcMtpRstrtT28

Overall restart timer for signaling point adjacent to one whose MTP restarts. Value range: 3 to 35 seconds. (Values are in tenths of a second.)

Default: 30

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
DlnkConnAckT7

Waiting for signaling data link connection acknowledgment. Value range: 1 to 5 seconds. (Values are in tenths of a second.) Default: 10

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
FrcUnhT13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
InhAckT14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds (Values are in tenths of a second.)

Default: 20

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
LocInhTstT20

Waiting to repeat local inhibit test. Value range: 90 to 120 seconds (Values are in tenths of a second.)

Default: 900

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
MaxSltTries

Maximum number of retries of signaling link test message. If MTP3 does not receive a response after two signaling link test messages, the system fails the link. Value range: 1 to 5.

Default: 2

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
MsgPriority

Message priority of management messages for congestion periods. Value range: 0 to 3.

Priority 1 (default) indicates that there are no congestion priorities. Priorities greater than 1 indicate multiple congestion priorities. Priority 3 is the highest priority.

Default: 2

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
MtpRstrtT24

Overall MTP restart timer for local MTP restart. Value range is network dependent. (Values are in tenths of a second.) Values: 0 to 2147483647.

Default: 100

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
Queue

Maximum number of queued messages for MTP3. Value 1024.

Default:1024

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
RepeatRstrtT26

Traffic restart waiting message at local MTP restart. Value range: 12 to 15 seconds. (Values are in tenths of a second.)

Default: 150

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
TfrUsed

Transfer restricted procedure is enabled (true) or disabled (false). Set to true or false.

Default: true

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
TraSntT29

Timer started when traffic restart allowed is sent in response to unexpected traffic restart allowed or traffic restart waiting. Value range: 0 to 65 seconds. (Values are in tenths of a second.)

Default: 600

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
tstSltmT1

Waiting for signaling link test acknowledgment message. Value range: 4 to 12 seconds.

Default: 60

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
tstSltmT2

Interval for sending signaling link test message. Value range: 30 to 90 seconds. (Values are in tenths of a second.)

Default: 600

SS7-ANSI

SS7-ANSI

SS7-ANSI.mtp3
UnhAckT12

Waiting for uninhibited acknowledgment. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-ANSI

SS7-ANSI

SS7-ANSI.reference

Denotes version of protocol standard supported for MTP. Values are ANSI88, ANSI92, ANSI96. Default: ANSI92.

SS7-ANSI

SS7-ANSI

SS7-ANSI.standard

Denotes version of protocol standard supported for SCCP and TCAP.

Default: ITU92

SS7-ANSI

SS7-ANSI

SS7-ANSI.unavailProc

Indicates the procedure to follow when no ISUP circuits are available. This value is taken from the originating trunk group and is used in call control when re-attempting occurs. Values: ALTRTE (alternate routing) or BLK (blocking).

Default: BLK

SS7-ANSI

SS7-ANSI

SS7-ANSI.variant

SS7 variant supported by local subsystem. Value range: SS7-ANSI, SS7-China, SS7-ITU, SS7-Japan, or SS7-UK.

Default: SS7-ANSI

SS7-ANSI

SS7-ANSI

SS7-China.mtp3
ApcMtpRstrtT21

Overall MTP restart timer at an SP adjacent to an SP whose MTP restarts. Value range: 0 to disable, or 63 to 65 seconds. (Values are in tenths of a second.)

Default: 0

SS7-China

SS7-China

SS7-China.mtp3
DlnkConnAckT7

Waiting for signaling data link connection acknowledgment. Value range: 1 to 5 seconds. (Values are in tenths of a second.) Default: 10

SS7-China

SS7-China

SS7-China.mtp3
FrcUnhT13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-China

SS7-China

SS7-China.mtp3
InhAckT14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds (Values are in tenths of a second.)

Default: 20

SS7-China

SS7-China

SS7-China.mtp3
LocInhTstT22

Waiting to repeat local inhibit test. Value range: 3 to 6 minutes. (Values are in tenths of a second.)

Default: 3000

SS7-China

SS7-China

SS7-China.mtp3
MaxSltTries

Maximum number of retries of signaling link test message. If MTP3 does not receive a response after two signaling link test messages, the system fails the link. Value range: 1 to 5.

Default: 2

SS7-China

SS7-China

SS7-China.mtp3
MsgPriority

Message priority of management messages for congestion periods. Value range: 0 to 3.

Priority 1 (default) indicates without congestion priorities. Priorities greater than 1 indicate multiple congestion priorities. Priority 3 is the highest priority.

Default: 2

SS7-China

SS7-China

SS7-China.mtp3
MtpRstrtT20

Overall MTP restart timer at the signaling point where MTP restarts. Value range: 0 to disable, or 50 to 61 seconds. (Values are in tenths of a second.)

Default: 0

SS7-China

SS7-China

SS7-China.mtp3
TfrUsed

Transfer restricted procedure is enabled (true) or disabled (false). Set to true or false.

Default: false

SS7-China

SS7-China

SS7-China.mtp3
tstSltmT1

Waiting for signaling link test acknowledgment message. Value range: 4 to 12 seconds.

Default: 50

SS7-China

SS7-China

SS7-China.mtp3
tstSltmT2

Interval for sending signaling link test message. Value range: 30 to 90 seconds. (Values are in tenths of a second.)

Default: 300

SS7-China

SS7-China

SS7-China.mtp3
UnhAckT12

Waiting for uninhibited acknowledgment. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-China

SS7-China

SS7-China.reference

Denotes version of protocol standard supported for MTP. Values are ANSI88, ANSI92, and ANSI96. Default: ANSI92.

SS7-China

SS7-China

SS7-ITU.mtp3ApcMtpRstrtT21

Overall MTP restart timer at an SP adjacent to an SP whose MTP restarts. Value range: 0 to disable, or 63 to 65 seconds. (Values are in tenths of a second.)

Default: 640

SS7-ITU

SS7-ITU

SS7-ITU.mtp3
DlnkConnAckT7

Waiting for signaling data link connection acknowledgment. Value range: 1 to 5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-ITU

SS7-ITU

SS7-ITU.mtp3
FrcUnhT13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-ITU

SS7-ITU

SS7-ITU.mtp3
InhAckT14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds (Values are in tenths of a second.)

Default: 20

SS7-ITU

SS7-ITU

SS7-ITU.mtp3
LocInhTstT22

Waiting to repeat local inhibit test. Value range: 3 to 6 minutes. (Values are in tenths of a second.)

Default: 3000

SS7-ITU

SS7-ITU

SS7-ITU.mtp3
MaxSltTries

Maximum number of retries of signaling link test message. If MTP3 does not receive a response after two signaling link test messages, the system fails the link. Value range: 1 to 5.

Default: 2

SS7-ITU

SS7-ITU

SS7-ITU.mtp3MsgPriority

Message priority of management messages for congestion periods. Value range: 0 to 3.

Priority 1 (default) indicates without congestion priorities. Priorities greater than 1 indicate multiple congestion priorities. Priority 3 is the highest priority.

Default: 2

SS7-ITU

SS7-ITU

SS7-ITU.mtp3MtpRstrtT20

Overall MTP restart timer at the signaling point where MTP restarts. Value range: 0 to disable, or 50 to 61 seconds. (Values are in tenths of a second.)

Default: 600

SS7-ITU

SS7-ITU

SS7-ITU.mtp3TfrUsed

Transfer restricted procedure is enabled (true) or disabled (false). Set to true or false.

Default: false

SS7-ITU

SS7-ITU

SS7-ITU.mtp3tstSltmT1

Waiting for signaling link test acknowledgment message. Value range: 4 to 12 seconds.

Default: 50

SS7-ITU

SS7-ITU

SS7-ITU.mtp3tstSltmT2

Interval for sending signaling link test message. Value range: 30 to 90 seconds. (Values are in tenths of a second.)

Default: 300

SS7-ITU

SS7-ITU

SS7-ITU.mtp3UnhAckT12

Waiting for uninhibited acknowledgment. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-ITU

SS7-ITU

SS7-ITU.reference

Denotes version of protocol standard supported for MTP. Values are ITU88, ITU92, and ITU96. Default: ITU92.

SS7-ITU

SS7-ITU

SS7-ITU.standard

Denotes version of protocol standard supported for SCCP and TCAP.

Default: ITU92

SS7-ITU

SS7-ITU

SS7-Japan.mtp3
ApcMtpRstrtT21

Overall MTP restart timer at an SP adjacent to an SP whose MTP restarts. Value range: 0 to disable, or 63 to 65 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
ClearTfc

Transfer controlled clear timer. Value range: 0 through 2147483647.

Default: 200

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
DlnkConnAckT7

Waiting for signaling data link connection acknowledgment. Value range: 1 to 5 seconds. (Values are in tenths of a second.)

Default: 20

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
FrcUnhT13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
InhAckT14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
LocInhTstT22

Waiting to repeat local inhibit test. Value range: 3 to 6 minutes. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
MaxSltTries

Maximum number of retries of signaling link test message. If MTP3 does not receive a response after two signaling link test messages, the system fails the link. Value range: 1 to 5.

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
MsgPriority

Message priority of management messages for congestion periods. Value range: 0 to 3.

Priority 1 (default) indicates without congestion priorities. Priorities greater than 1 indicate multiple congestion priorities. Priority 3 is the highest priority.

Default: 2

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
MtpRstrtT20

Overall MTP restart timer at the signaling point where MTP restarts. Value range: 0 to disable, or 50 to 61 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T12

Waiting for signaling data link connection acknowledgment. Value range: 500 through 1500 milliseconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T20

Overall MTP restart timer at the signaling point whose MTP restarts. Value range: 50 to 61 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T21

Overall MTP restart timer at an SP adjacent to an SP whose MTP restarts. Value range: 63 to 65 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
T22

Waiting to repeat local inhibit test. Value range: 3 to 6 minutes. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3T7

Waiting for signaling data link connection acknowledgment. Value range: 1 through 20 seconds. (Values are in tenths of a second.)

Default: 20

SS7-Japan

SS7-Japan

SS7-Japan.mtp3Tc

Transfer controlled status cancel timer. Value range: 0 through 2147483647.

Default: 200

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
TfrUsed

Transfer restricted procedure is enabled (true) or disabled (false). Set to true or false.

Default: false

SS7-Japan

SS7-Japan

SS7-Japan.mtp3tstSltmT1

MTP3 test signaling link test timer T1. Waiting for signaling link test acknowledgment message. Value range: 4 through 12 seconds.

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3tstSltmT2

MTP3 test signaling link test timer T2. Interval for sending signaling link test message. Value range: 0, 30 through 90 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
UnhAckT12

Waiting for uninhibited acknowledgment. Value range:0, 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.mtp3
TstSrtaT10

Timer for waiting to repeat signaling route set test. Value range: 0 through 2147483647.

Default: 50

SS7-Japan

SS7-Japan

SS7-Japan.
reference

Denotes version of protocol standard supported for MTP. Values are NTT, NTT92, and TTC. Default: NTT.

SS7-Japan

SS7-Japan

SS7-Japan.sltmT1

Signaling link test timer T1. Waiting for signaling link test acknowledgment message. Value range: 0 through 2147483647.

Default: 0

SS7-Japan

SS7-Japan

SS7-Japan.sltmT2

Signaling link test timer T2. Interval for sending signaling link test message. Value range: 0 through 2147483647. (Values are in tenths of a second.)

Default: 0

SS7-Japan

SS7-Japan

SS7-UK.mtp3ApcMtpRstrtT21

Overall MTP restart timer at an SP adjacent to an SP whose MTP restarts. Value range: 0 to disable, or 20, 63 to 65 seconds. (Values are in tenths of a second.)

Default: 20

SS7-UK

SS7-UK

SS7-UK.mtp3DlnkConnAckT7

Waiting for signaling data link connection acknowledgment. Value range: 1 to 5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-UK

SS7-UK

SS7-UK.mtp3Frc
UnhT13

Waiting for force uninhibited. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-UK

SS7-UK

SS7-UK.mtp3Inh
AckT14

Waiting for inhibit acknowledgment. Value range: 2 to 3 seconds (Values are in tenths of a second.)

Default: 20

SS7-UK

SS7-UK

SS7-UK.mtp3Loc
InhTstT22

Waiting to repeat local inhibit test. Value range: 3 to 6 minutes. (Values are in tenths of a second.)

Default: 3000

SS7-UK

SS7-UK

SS7-UK.mtp3MaxSltTries

Maximum number of retries of signaling link test message. If MTP3 does not receive a response after two signaling link test messages, the system fails the link. Value range: 1 to 5.

Default: 2

SS7-UK

SS7-UK

SS7-UK.mtp3MsgPriority

Message priority of management messages for congestion periods. Value range: 0 to 3.

Priority 1 indicates without congestion priorities. Priorities greater than 1 indicate multiple congestion priorities. Priority 3 is the highest priority.

Default: 2

SS7-UK

SS7-UK

SS7-UK.mtp3MtpRstrtT20

Overall MTP restart timer at the signaling point whose MTP restarts. Value range: 0 to disable, 20, or 50 to 61 seconds. (Values are in tenths of a second.)

Default: 20

SS7-UK

SS7-UK

SS7-UK.mtp3Tfr
Used

Transfer restricted procedure is enabled (true) or disabled (false). Set to true or false.

Default: false

SS7-UK

SS7-UK

SS7-UK.mtp3tst
SltmT1

Waiting for signaling link test acknowledgment message. Value range: 4 to 12 seconds.

Default: 50

SS7-UK

SS7-UK

SS7-UK.mtp3tst
SltmT2

Interval for sending signaling link test message. Value range: 30 to 90 seconds. (Values are in tenths of a second.)

Default: 300

SS7-UK

SS7-UK

SS7-UK.mtp3UnhAckT12

Waiting for uninhibited acknowledgment. Value range: 0.8 through 1.5 seconds. (Values are in tenths of a second.)

Default: 10

SS7-UK

SS7-UK

SS7-UK.reference

Denotes version of protocol standard supported for MTP. Values are UK and UK92. Default: UK.

SS7-UK

SS7-UK

1 NI = network identity


ISUP Timers

The following list identifies the ISUP timers that can be provisioned for signaling service. Information for each timer consists of:

Default—Indicates if it is assigned to a profile. Set to 0 for no profile.

Components—Identifies the protocol variants supported, the default value, and the range for each protocol variant.

*.T1

Desc: T1

Default: 0

Type:

Components:

SigPath Profile = Yes

SS7-ANSI

ANSISS7_STANDARD Default: 4000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 4000 Range=4000-15000

Q761_SINGAPORE Default: 15000 Range=15000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=10000-60000

*.T12

Desc: T12

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 6000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 15000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=15000-60000

*.T13

Desc: T13

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 300000 Range=60000-900000

*.T14

Desc: T14

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 6000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 15000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=15000-60000

*.T15

Desc: T15

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 6000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 300000 Range=300000-900000

*.T16

Desc: T16

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 5000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 5000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=10000-60000

*.T17

Desc: T17

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 60000 Range=60000-900000

*.T18

Desc: T18

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 15000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 15000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=15000-60000

*.T19

Desc: T19

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 300000 Range=300000-900000

*.T2

Desc: T2

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 180000 Range=180000-180000

SS7-ITU

Q761_BASE Default: 180000 Range=180000-180000

Q767_BASE Default: 180000 Range=180000-180000

Q761_SINGAPORE Default: 180000 Range=180000-180000

Q761_ARGENTINA Default: 180000 Range=180000-180000

ISUPV2_SPANISH Default: 180000 Range=180000-180000

ISUPV2_FINNISH96 Default: 180000 Range=180000-180000

ISUPV2_FRENCH Default: 180000 Range=180000-180000

Q761_THAILAND Default: 180000 Range=180000-180000

Q761_PERU Default: 180000 Range=180000-180000

Q761_BELG_C2 Default: 180000 Range=180000-180000

SS7-Japan

ISUPV2_JAPAN Default: 180000 Range=180000-180000

*.T20

Desc: T20

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 15000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 15000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=15000-60000

*.T21

Desc: T21

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 300000 Range=300000-900000

*.T22

Desc: T22

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 15000 Range=4000-15000

SS7-ITU

Q761_BASE Default: 15000 Range=15000-60000

Q767_BASE Default: 15000 Range=4000-15000

Q761_SINGAPORE Default: 60000 Range=60000-60000

Q761_ARGENTINA Default: 10000 Range=10000-60000

ISUPV2_SPANISH Default: 30000 Range=10000-60000

ISUPV2_FINNISH96 Default: 15000 Range=15000-60000

ISUPV2_FRENCH Default: 15000 Range=15000-60000

Q761_THAILAND Default: 15000 Range=15000-60000

Q761_PERU Default: 30000 Range=15000-60000

Q761_BELG_C2 Default: 15000 Range=15000-60000

SS7-Japan

ISUPV2_JAPAN Default: 10000 Range=10000-60000

*.T23

Desc: T23

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 60000 Range=60000-900000

*.T24

Desc: T24

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 20000 Range=20000-20000

SS7-ITU

Q761_BASE Default: 2000 Range=0-2000

Q767_BASE Default: 2000 Range=0-2000

Q761_SINGAPORE Default: 2000 Range=2000-2000

Q761_ARGENTINA Default: 2000 Range=2000-2000

ISUPV2_SPANISH Default: 1500 Range=1500-2000

ISUPV2_FINNISH96 Default: 2000 Range=0-2000

ISUPV2_FRENCH Default: 2000 Range=0-2000

Q761_THAILAND Default: 2000 Range=0-2000

Q761_PERU Default: 15000 Range=0-2000

Q761_BELG_C2 Default: 2000 Range=0-2000

SS7-Japan

ISUPV2_JAPAN Default: 2000 Range=0-2000

*.T25

Desc: T25

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 1000 Range=1000-10000

SS7-ITU

Q761_BASE Default: 2000 Range=1000-10000

Q767_BASE Default: 2000 Range=1000-10000

Q761_SINGAPORE Default: 10000 Range=1000-10000

Q761_ARGENTINA Default: 10000 Range=1000-10000

ISUPV2_SPANISH Default: 10000 Range=1000-10000

ISUPV2_FINNISH96 Default: 2000 Range=1000-10000

ISUPV2_FRENCH Default: 2000 Range=1000-10000

Q761_THAILAND Default: 2000 Range=1000-10000

Q761_PERU Default: 10000 Range=1000-10000

Q761_BELG_C2 Default: 2000 Range=1000-10000

SS7-Japan

ISUPV2_JAPAN Default: 2000 Range=1000-10000

*.T26

Desc: T26

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 120000 Range=60000-180000

SS7-ITU

Q761_BASE Default: 180000 Range=60000-180000

Q767_BASE Default: 180000 Range=60000-180000

Q761_SINGAPORE Default: 180000 Range=60000-180000

Q761_ARGENTINA Default: 120000 Range=60000-180000

ISUPV2_SPANISH Default: 120000 Range=60000-180000

ISUPV2_FINNISH96 Default: 180000 Range=60000-180000

ISUPV2_FRENCH Default: 180000 Range=60000-180000

Q761_THAILAND Default: 180000 Range=60000-180000

Q761_PERU Default: 120000 Range=60000-180000

Q761_BELG_C2 Default: 180000 Range=60000-180000

SS7-Japan

ISUPV2_JAPAN Default: 180000 Range=60000-180000

*.T27

Desc: T27

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 240000 Range=180000-240000

SS7-ITU

Q761_BASE Default: 240000 Range=240000-240000

Q767_BASE Default: 240000 Range=240000-240000

Q761_SINGAPORE Default: 240000 Range=240000-240000

Q761_ARGENTINA Default: 240000 Range=240000-240000

ISUPV2_SPANISH Default: 240000 Range=240000-240000

ISUPV2_FINNISH96 Default: 240000 Range=240000-240000

ISUPV2_FRENCH Default: 240000 Range=240000-240000

Q761_THAILAND Default: 240000 Range=240000-240000

Q761_PERU Default: 240000 Range=240000-240000

Q761_BELG_C2 Default: 240000 Range=240000-240000

SS7-Japan

ISUPV2_JAPAN Default: 240000 Range=240000-240000

*.T28

Desc: T28

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 10000 Range=10000-10000

SS7-ITU

Q761_BASE Default: 10000 Range=10000-10000

Q761_SINGAPORE Default: 10000 Range=10000-10000

Q761_ARGENTINA Default: 10000 Range=10000-10000

ISUPV2_SPANISH Default: 10000 Range=10000-10000

ISUPV2_FINNISH96 Default: 10000 Range=10000-10000

ISUPV2_FRENCH Default: 10000 Range=10000-10000

Q761_THAILAND Default: 10000 Range=10000-10000

Q761_PERU Default: 10000 Range=10000-10000

Q761_BELG_C2 Default: 10000 Range=10000-10000

SS7-Japan

ISUPV2_JAPAN Default: 10000 Range=10000-10000

*.T33

Desc: T33

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 120000 Range=120000-120000

SS7-ITU

Q761_BASE Default: 15000 Range=12000-15000

Q767_BASE Default: 120000 Range=120000-120000

Q761_SINGAPORE Default: 14000 Range=12000-15000

Q761_ARGENTINA Default: 15000 Range=12000-15000

ISUPV2_SPANISH Default: 15000 Range=12000-15000

ISUPV2_FINNISH96 Default: 15000 Range=12000-15000

ISUPV2_FRENCH Default: 15000 Range=12000-15000

Q761_THAILAND Default: 15000 Range=12000-15000

Q761_PERU Default: 15000 Range=12000-15000

Q761_BELG_C2 Default: 15000 Range=12000-15000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=12000-15000

*.T34

Desc: T34

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 10000 Range=10000-10000

SS7-ITU

Q761_BASE Default: 2000 Range=2000-4000

Q761_SINGAPORE Default: 3800 Range=2000-4000

Q761_ARGENTINA Default: 15000 Range=2000-15000

ISUPV2_SPANISH Default: 2000 Range=2000-15000

ISUPV2_FINNISH96 Default: 2000 Range=2000-4000

ISUPV2_FRENCH Default: 4000 Range=2000-4000

Q761_THAILAND Default: 2000 Range=2000-4000

Q761_PERU Default: 2000 Range=2000-4000

Q761_BELG_C2 Default: 2000 Range=2000-4000

SS7-Japan

ISUPV2_JAPAN Default: 2000 Range=2000-4000

*.T35

Desc: T35

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ITU

Q761_BASE Default: 15000 Range=15000-20000

Q767_BASE Default: 15000 Range=15000-20000

Q761_SINGAPORE Default: 15000 Range=15000-20000

Q761_ARGENTINA Default: 15000 Range=15000-20000

ISUPV2_SPANISH Default: 15000 Range=15000-20000

ISUPV2_FINNISH96 Default: 15000 Range=15000-20000

ISUPV2_FRENCH Default: 15000 Range=15000-20000

Q761_THAILAND Default: 15000 Range=15000-20000

Q761_PERU Default: 15000 Range=15000-20000

Q761_BELG_C2 Default: 15000 Range=15000-20000

SS7-Japan

ISUPV2_JAPAN Default: 15000 Range=15000-20000

*.T36

Desc: T36

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 10000 Range=10000-10000

SS7-ITU

Q761_BASE Default: 10000 Range=10000-15000

Q767_BASE Default: 10000 Range=10000-15000

Q761_SINGAPORE Default: 10000 Range=1000-15000

Q761_ARGENTINA Default: 10000 Range=1000-15000

ISUPV2_SPANISH Default: 15000 Range=1000-15000

ISUPV2_FINNISH96 Default: 10000 Range=10000-15000

ISUPV2_FRENCH Default: 10000 Range=10000-15000

Q761_THAILAND Default: 10000 Range=10000-15000

Q761_PERU Default: 15000 Range=10000-15000

Q761_BELG_C2 Default: 10000 Range=10000-15000

SS7-Japan

ISUPV2_JAPAN Default: 10000 Range=10000-15000

*.T38

Desc: T38

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ITU

Q761_BASE Default: 125000 Range=125000-125000

Q761_SINGAPORE Default: 125000 Range=125000-125000

Q761_ARGENTINA Default: 125000 Range=125000-125000

ISUPV2_SPANISH Default: 125000 Range=125000-125000

ISUPV2_FINNISH96 Default: 125000 Range=125000-125000

ISUPV2_FRENCH Default: 125000 Range=125000-125000

Q761_THAILAND Default: 125000 Range=125000-125000

Q761_BELG_C2 Default: 125000 Range=125000-125000

SS7-Japan

ISUPV2_JAPAN Default: 125000 Range=125000-125000

*.T5

Desc: T5

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 60000 Range=60000-60000

SS7-ITU

Q761_BASE Default: 300000 Range=300000-900000

Q767_BASE Default: 60000 Range=60000-60000

Q761_SINGAPORE Default: 300000 Range=300000-900000

Q761_ARGENTINA Default: 60000 Range=60000-900000

ISUPV2_SPANISH Default: 600000 Range=60000-900000

ISUPV2_FINNISH96 Default: 300000 Range=300000-900000

ISUPV2_FRENCH Default: 300000 Range=300000-900000

Q761_THAILAND Default: 60000 Range=60000-900000

Q761_PERU Default: 600000 Range=300000-900000

Q761_BELG_C2 Default: 300000 Range=300000-900000

SS7-Japan

ISUPV2_JAPAN Default: 60000 Range=60000-900000

*.T6

Desc: T6

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 32000 Range=10000-32000

SS7-ITU

Q761_BASE Default: 120000 Range=60000-120000

Q767_BASE Default: 120000 Range=60000-120000

Q761_SINGAPORE Default: 20000 Range=20000-130000

Q761_ARGENTINA Default: 60000 Range=10000-60000

ISUPV2_SPANISH Default: 60000 Range=10000-60000

ISUPV2_FINNISH96 Default: 120000 Range=60000-120000

ISUPV2_FRENCH Default: 60000 Range=60000-120000

Q761_THAILAND Default: 90000 Range=60000-120000

Q761_PERU Default: 15000 Range=15000-120000

Q761_BELG_C2 Default: 120000 Range=60000-120000

SS7-Japan

ISUPV2_JAPAN Default: 3000 Range=2000-4000

*.T7

Desc: T7

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 30000 Range=20000-30000

SS7-ITU

Q761_BASE Default: 30000 Range=20000-30000

Q767_BASE Default: 30000 Range=20000-30000

Q761_SINGAPORE Default: 20000 Range=20000-30000

Q761_ARGENTINA Default: 20000 Range=20000-30000

ISUPV2_SPANISH Default: 20000 Range=20000-30000

ISUPV2_FINNISH96 Default: 30000 Range=20000-30000

ISUPV2_FRENCH Default: 30000 Range=20000-30000

Q761_THAILAND Default: 30000 Range=20000-30000

Q761_PERU Default: 20000 Range=20000-30000

Q761_BELG_C2 Default: 40000 Range=20000-50000

SS7-Japan

ISUPV2_JAPAN Default: 30000 Range=20000-30000

*.T8

Desc: T8

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 10000 Range=10000-15000

SS7-ITU

Q761_BASE Default: 10000 Range=10000-15000

Q767_BASE Default: 10000 Range=10000-15000

Q761_SINGAPORE Default: 10000 Range=10000-15000

Q761_ARGENTINA Default: 15000 Range=10000-15000

ISUPV2_SPANISH Default: 15000 Range=10000-15000

ISUPV2_FINNISH96 Default: 10000 Range=10000-15000

ISUPV2_FRENCH Default: 10000 Range=10000-15000

Q761_THAILAND Default: 10000 Range=10000-15000

Q761_PERU Default: 15000 Range=10000-15000

Q761_BELG_C2 Default: 10000 Range=10000-15000

SS7-Japan

ISUPV2_JAPAN Default: 10000 Range=10000-15000

*.T9

Desc: T9

Default: 0

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

ANSISS7_STANDARD Default: 120000 Range=120000-240000

SS7-ITU

Q761_BASE Default: 120000 Range=60000-120000

Q767_BASE Default: 120000 Range=60000-120000

Q761_SINGAPORE Default: 90000 Range=60000-240000

Q761_ARGENTINA Default: 120000 Range=60000-240000

ISUPV2_SPANISH Default: 60000 Range=60000-240000

ISUPV2_FINNISH96 Default: 180000 Range=120000-240000

ISUPV2_FRENCH Default: 120000 Range=60000-120000

Q761_THAILAND Default: 120000 Range=60000-120000

Q761_PERU Default: 60000 Range=60000-120000

Q761_BELG_C2 Default: 120000 Range=60000-120000

SS7-Japan

ISUPV2_JAPAN Default: 120000 Range=60000-120000

T_CCR

Desc: T_CCR

Default: 2000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_CCRR

Desc: T_CCRR

Default: 20000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_CGB

Desc: T_CGB

Default: 5000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_CGBA

Desc: T_CGBA

Default: 5000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_CRA

Desc: T_CRA

Default: 20000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_CVT

Desc: T_CVT

Default: 10000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

T_GRS

Desc: T_GRS

Default: 5000

Type:

Components:

SigPath Profile=Yes

SS7-ANSI

Protocol Variants