Enable Auto Network Detect
|
When True, the VPN client can only run when it detects that it
is out of the corporate network.
Default: False
|
MTU
|
This field specifies the maximum transmission unit:
Default: 1290 bytes
Minimum: 256 bytes
Maximum: 1406 bytes
|
Keep Alive
|
This field specifies the rate at which the system sends the keep
alive message.
Note
|
If it is non zero and less than the value specified in Unified Communications Manager, the keep alive setting in the VPN concentrator overwrites this setting.
|
Default: 60 seconds
Minimum: 0
Maximum: 120 seconds
|
Fail to Connect
|
This field specifies the amount of time to wait for login or
connect operations to complete while the system creates the VPN tunnel.
Default: 30 seconds
Minimum: 0
Maximum: 600 seconds
|
Client Authentication Method
|
From the drop-down list, choose the client authentication
method:
-
User
and password
-
Password only
-
Certificate (LSC or MIC)
Default: User And Password
|
Enable Password Persistence
|
When True, a user password gets saved in the phone until either
a failed login attempt occurs, a user manually clears the password, or the
phone resets or loses power.
Default: False
|
Enable Host ID Check
|
When True, the gateway certificate subjectAltName or CN must
match the URL to which the VPN client is connected.
Default: True
|