Technical Specifications

Physical Specifications

Environmental Specifications

Power Specifications


Technical Specifications


This appendix lists the technical specifications for the Cisco UCS C250 server and includes the following sections:

Physical Specifications

Environmental Specifications

Power Specifications

Physical Specifications

Table A-1 lists the physical specifications for the server.

Table A-1 Physical Specifications

Description
Specification

Height

3.45 in. (8.75 cm)

Width

17.25 in. (43.82 cm)

Depth (including power supply handle)

29.30 in. (74.42 cm)

Weight

51.50 lbs (23.36 kg)


Environmental Specifications

Table A-2 lists the environmental specifications for the server.

Table A-2 Environmental Specifications

Description
Specification

Temperature, operating:
Derate 1°C for every 1000 ft (304 m) up to a maximum altitude of 10,000 ft (3048 m).

50 to 95°F (10 to 35°C)

Temperature, nonoperating
within altitude: 0 to 40,000 feet (0 to 12,000 meters)

-40 to 149°F (-40 to 65°C)

Humidity (RH), noncondensing

5 to 93%

Altitude

0 to 10000 feet

Sound Pressure Level (dBA)

83 dB sound power—at normal operating temperature


Power Specifications

Table A-3 lists the specifications for each power supply.

Table A-3 Power Supply Specifications

Description
Specification

Input Requirements

Rated input voltage

115 to 240 VAC nominal
(Range: 90 to 264 VAC)

Rated input frequency

50 to 60 Hz nominal
(Range: 47 to 63 Hz)

Maximum input current

10 Amps at 100 VAC

Maximum inrush current

35 A for Yms

Input connector

IEC60320 C14

Power Supply Output

Maximum output power for each power supply

750 W (up to two power supplies can be installed)

Power supply output voltage

Main power: 12 VDC

Standby power: 12 VDC

Power Supply Information

Maximum hold-up time

12 ms

Efficiency rating

Climate Savers Gold


You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator: