Cisco TelePresence System 500-32 Assembly, Use & Care, and Field-Replaceable Unit Guide
Room Recommendations and System Specifications
Downloads: This chapterpdf (PDF - 749.0KB) The complete bookPDF (PDF - 14.88MB) | Feedback

Room Requirements and System Specifications

Table Of Contents

Room Requirements and System Specifications

Room Size and System-to-User Distance Recommendations

CTS-500-32 Power Consumption

Height, Width and Weight of Pedestal-Mounted CTS-500-32

Height, Width and Weight of Table Stand-Mounted CTS-500-32


Room Requirements and System Specifications


June 5, 2013, OL-23420-01

This chapter describes the room sizes that are supported for the CTS-500-32 and the size of the system and includes the following sections:

Room Size and System-to-User Distance Recommendations

CTS-500-32 Power Consumption

Height, Width and Weight of Pedestal-Mounted CTS-500-32

Height, Width and Weight of Table Stand-Mounted CTS-500-32

Room Size and System-to-User Distance Recommendations

Figure 1-1 shows the minimum and maximum recommended room sizes for a CTS-500-32 and the range of distance that is recommended between the front of the system display and the user. Figure 1-2 through Figure 1-4 show additional room recommendations for various room configurations.


Note The CTS-500-32 allows for a wide range of distance between the system and the user. Note, however, that the size of the user increases the closer you get to the system, and becomes smaller the farther away you get from the systems. To compensate for the increased or reduced size, you can zoom the camera lens. See the "Adjusting the Camera Lens to Resize the User" section for more information.


Figure 1-1 Room Size and Seating Distance Recommendations

Figure 1-2 Room Size and Seating Distance Recommendations — CTS-500-32 With a Two Users and a Freestanding Desk

Figure 1-3 Room Size and Seating Distance Recommendations —CTS-500-32 With a Single User and Freestanding Desk

Figure 1-4 Room Size and Seating Distance Recommendations —CTS-500-32 Placed in a Corner

CTS-500-32 Power Consumption

Table 1-1 shows the power consumption numbers for the CTS-500-32.

Table 1-1 CTS-500-32 Power Consumption 

Component
Maximum
Typical
Standby/Idle
 
kW
Amperage @120V
kW
Amperage @120V
kW
Amperage @120V

LCD Display and Lights1

0.152

1.270

0.143

1.200

0.001

0.010

Codec

0.091

0.760

0.069

0.580

0.066

0.550

Audio/Video Extension Unit

0.010

0.080

0.008

0.070

0.005

0.040

Presentation Display (optional)

0.155

1.290

0.020

0.170

0.001

0.010

POWER TOTAL for CTS-500-32

0.408

3.400

0.240

2.020

0.073

0.610

1 The display and lights use the same power source.


Height, Width and Weight of Pedestal-Mounted CTS-500-32

Figure 1-5 shows the dimensions of an assembled CTS-500-32 pedestal mount system.

Figure 1-5 CTS-500-32 Dimensions

Height, Width and Weight of Table Stand-Mounted CTS-500-32

The following are the dimensions of the table stand-mounted CTS-500-32:

Height: 27 inches, +/-2 inches (69 cm +/- 5 cm)

Base Depth: 13 inches (33 cm)

Base Width: 24 inches (61 cm)

Weight of desktop and stand: 30 lbs (14 kg)

Weight of display and codec: 47 lbs (21 kg)