Guest

Cisco FastHub 400 10/100 Series Repeaters

Release Notes for the FastHub 400 10/100 Series

  • Viewing Options

  • PDF (140.7 KB)
  • Feedback
Release Notes for the FastHub 400 10/100 Series

Table Of Contents

Release Notes for the
FastHub 400 10/100 Series

Contents

New and Changed Information

Firmware Release v1.00.03

Limitations

Usage Guidelines

Stacking Guidelines

Example

Clearing the NVRAM of a Management Hub in a Redundant Stack

Related Documentation

Obtaining Documentation

World Wide Web

Documentation CD-ROM

Ordering Documentation

Obtaining Technical Assistance

Cisco Connection Online

Technical Assistance Center

Documentation Feedback


Release Notes for the
FastHub 400 10/100 Series


June 30, 2000

These release notes provide information on the FastHub 400 10/100 Series (hereafter referred to as the FastHub 400 models).

Contents

"New and Changed Information" section

"Limitations" section

"Usage Guidelines" section

"Related Documentation" section

"Obtaining Documentation" section

"Obtaining Technical Assistance" section

The tracking numbers for some items in this document are added for your convenience.

New and Changed Information

Firmware Release v1.00.03

Using Cisco Discovery Protocol (CDP) with a FastHub 400M no longer causes occasional console lockup. [CSCdr17179]

Limitations

The FastHub 400M model can store up to 4096 MAC addresses in memory; the optional switched uplink modules can store up to 1536 MAC addresses. If you experience excessive flooding of unicast packets on these devices, your hub or module might have reached its maximum. To clear the MAC address table, power-cycle the hub. [CSCdk90641]

Usage Guidelines

Some series 400 FastHubs have improperly terminated 100-Mb TXEN signal lines at the extension port. If this problem occurs when no extension module is present, 100-Mb data can be corrupted. Firmware Release 1.00.02 and higher detects the absence of an extension module and isolates the extension port from the hub.

Before connecting a FastHub 400M model to a modem, you should configure your modem to ignore input from the data terminal equipment (DTE) during dial-out or dial-in. Without this precaution, there is a small chance that the modem could disconnect. Refer to your modem manual for the correct configuration command syntax. [CSCdk83978] [CSCdk83009]

You must purchase and use the FastHub 400 stacking cable (Part Number WS-C400-CAB-EXP) to create a hub stack of interconnected FastHub 400 models. Do not use any other cable for this purpose. You can order this cable from your Cisco representative or reseller.

Stacking Guidelines

When changing or moving units within a managed hub stack, note these configuration rules.

The stacking cable connectors are lockable. When you insert the stacking cable, be sure it snaps into place.

The stacking cables are not hot-swappable. You must power down the hub stack before connecting or disconnecting a stacking cable. If you connect or disconnect a stacking cable while the power is on, power-cycle the stack to ensure correct stack management operation.

The M1 hub continuously stores the configuration settings for the following stack elements:


Note The primary management hub is referred to as the M1 hub, the secondary management hub as the M2 hub.


Itself

The most recent three hubs it has managed (whether or not they are currently being managed)

One each Tx and Fx switched uplink module for itself and each of the most recent three hubs it has managed.

This means that if you remove a hub (other than the M1 hub) or module from the stack and later reinstall the same device, that device can assume its former configuration in the stack through the M1 hub. Whether or not this happens depends upon whether the stored configuration for that particular device has been retained by the M1 hub or overwritten through intervening changes. [CSCdk90005]

Example

For example, in a stack of hubs in which hub 1 is the FastHub 400 model M1 hub and hubs 2, 3, and 4 are FastHub 400 model unmanaged hubs, the following conditions would apply:

If you remove hub 3 and replace it with a new hub (hub A), the new hub would keep its default configuration:

Table 1

Original Stack
Replace with
New Stack

Hub 1

 

Hub 1 (store M1)

Hub 2

 

Hub 2 (store 2)

(Hub 3) ---->

Hub A ---->

Hub 3 (store A: default)

Hub 4

 

Hub 4 (store 4)


If hub 4 was removed for troubleshooting purposes and later reinstalled in the second position in the stack, the M1 hub would recognize the serial number of that hub as belonging to one of its saved configurations and would apply the previously saved hub 4 configuration.

Table 2

Original Stack
 
New Stack

Hub 1

 

Hub 1 (store M1)

Hub 2 ------->

Hub 4 ---->

Hub 2 (store 4: saved)

Hub 3A ---->

 

Hub 3 (store 2: saved)

(Hub 4)

 

Hub 4 (store 3A: saved)


Clearing the NVRAM of a Management Hub in a Redundant Stack

To reset the nonvolatile RAM (NVRAM) configuration settings of one or both management hubs in a redundant stack configuration, note the following guidelines.


Note The primary management hub is referred to as the M1 hub, the secondary management hub as the M2 hub.


When a second FastHub 400 model managed hub is added to a stack, the new M2 hub learns the saved configuration settings for the stack from the M1 hub. If the M1 hub fails, the M2 hub uses the saved configuration of the M1 hub. [CSCdk91393]

You must power down the stack before resetting either or both management hubs.

To do this, unplug the stacking cable from the management hubs you want to clear.

Connect the hub to a management station

Power on the hub and access the command-line interface (CLI).

Refer to the online reference FastHub 400 10/100 Series Command Reference for information about accessing the CLI. See the "Obtaining Documentation" section of this release note for information about locating this online-only document through the Cisco web.

Use the CLI delete nvram command to reset either or both management hubs to default values.

Refer to the online reference FastHub 400 10/100 Series Command Reference for more information about this command.

Whichever management hub is powered on first becomes the new M1 hub in the stack because the hub with the longest up time is by default the M1. If you delete the NVRAM configuration settings for one management hub and not the other, be sure to power on the management hub with the cleared configuration first. This prevents the redundant management hub from copying its saved configuration to the hub whose configuration you just cleared.

Related Documentation

Use the following publications with this document:

FastHub 400 10/100 Series Cabling and Start Up

FastHub 400 10/100 Series Installation and Configuration Guide

Installation Notes for the FastHub 400 10/100 Series Switched Uplink Modules

FastHub 400 10/100 Series Command Reference (online only)

FastHub 400 10/100 series Hub Manager online help

Obtaining Documentation

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly. Therefore, it is probably more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.

Ordering Documentation

Registered CCO users can order the Documentation CD-ROM and other Cisco Product documentation through our online Subscription Services at http://www.cisco.com/cgi-bin/subcat/kaojump.cgi.

Nonregistered CCO users can order documentation through a local account representative by calling Cisco's corporate headquarters (California, USA) at 408 526-4000 or, in North America, call 800 553-NETS (6387).

Obtaining Technical Assistance

Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.

Cisco Connection Online

Cisco continues to revolutionize how business is done on the Internet. Cisco Connection Online is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.

CCO's broad range of features and services helps customers and partners to streamline business processes and improve productivity. Through CCO, you will find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online support services, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.

Customers and partners can self-register on CCO to obtain additional personalized information and services. Registered users may order products, check on the status of an order and view benefits specific to their relationships with Cisco.

You can access CCO in the following ways:

WWW: www.cisco.com

Telnet: cco.cisco.com

Modem using standard connection rates and the following terminal settings: VT100 emulation; 8 data bits; no parity; and 1 stop bit.

From North America, call 408 526-8070

From Europe, call 33 1 64 46 40 82

You can e-mail questions about using CCO to cco-team@cisco.com.

Technical Assistance Center

The Cisco Technical Assistance Center (TAC) is available to warranty or maintenance contract customers who need technical assistance with a Cisco product that is under warranty or covered by a maintenance contract.

To display the TAC web site that includes links to technical support information and software upgrades and for requesting TAC support, use www.cisco.com/techsupport.

To contact by e-mail, use one of the following:

Language
E-mail Address

English

tac@cisco.com

Hanzi (Chinese)

chinese-tac@cisco.com

Kanji (Japanese)

japan-tac@cisco.com

Hangul (Korean)

korea-tac@cisco.com

Spanish

tac@cisco.com

Thai

thai-tac@cisco.com


In North America, TAC can be reached at 800 553-2447 or 408 526-7209. For other telephone numbers and TAC e-mail addresses worldwide, consult the following web site: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.

Documentation Feedback

If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.

You can e-mail your comments to bug-doc@cisco.com.

To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:

Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate and value your comments.