Catalyst 4000 Series Installation Guide
Specifications
Downloads: This chapterpdf (PDF - 191.0KB) | Feedback

Specifications

Table Of Contents

Specifications

Catalyst 4003 Switch Specifications

Catalyst 4006 Switch Specifications


Specifications


This appendix provides cable and technical specifications for Catalyst 4000 series switches.

Catalyst 4003 Switch Specifications

Table A-1 lists the Catalyst 4003 switch specifications.

Table A-1 Catalyst 4003 Switch Specifications 

Item
Specification
Environmental
   

Temperature,
ambient operating


32 to 104°F (0 to 40°C)

Temperature,
ambient nonoperating and storage


-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing), operating


10 to 90%

Humidity (RH), ambient (noncondensing), nonoperating and storage


5 to 95%

Altitude,
operating and nonoperating


-200 to 6500 ft. (-60 to 2000 m)

Switching Components
 

Backplane

12-Gbps full duplex

Microprocessor

Supervisor engine: 150-MHz R5000 RISC

Memory
 

Supervisor engine

SDRAM: 32-MB on board, 32-MB DIMM (1Mx4x72, 168-pin, 100-MHz, nonregistered, 3.3 V), 16-MB Flash, 512-KB NVRAM

Physical Characteristics
   

Dimensions (H x W x D)

10.50 x 17.25 x 11.81 in. (26.6 x 43.7 x 30 cm)

Weight

Minimum weight: 27.5 lb (12 kg)
Maximum weight: 40 lb (18 kg)

400 W AC Power Supply
   

Power supply output current

+12 V @ 33.3 A (maximum)

AC-input voltage

100 to 240 VAC

AC frequency

50 to 60 Hz

AC-input current

6.0 A maximum @ 100-VAC 60 Hz per power supply
3.0 A maximum @ 240-VAC 50 Hz per power supply

KVA rating

0.58 KVA

 

Heat dissipation

530 W maximum (1800 Btus per hour)

400 W DC Power Supply
   

Power supply output current

+12 V @ 33.3 A (maximum) per power supply

DC-input voltage

-48 to -60 VDC per power supply

DC-input current

11 A per power supply

KVA rating

0.53 KVA

 

Heat dissipation

443.7 W maximum (1800 Btus per hour)

Input terminal block

The terminal block accepts 22-12 AWG copper conductors. The installer or local electrician must determine the actual size of the wire. The terminal block material is rated at 105°C.

650 W DC Power Supply
   

Power supply output current

+12 V @ 55.09 A (maximum) per power supply

DC-input voltage

-48 to -60 VDC per power supply

DC-input current

18 A per power supply

KVA rating

0.866 KVA

 

Heat dissipation

866.66 W maximum (2957.91 Btus per hour)

Input terminal block

The terminal block accepts 22-12 AWG copper conductors. The installer or local electrician must determine the actual size of the wire. The terminal block material is rated at 95°C.

Airflow
 

Switch

Right to left

 

Power supply

Front to back

 
Standards Compliance
   
Compliance

CE1 Marking

Safety

UL2 1950, CSA3 -C22.2 No. 950, EN4 60950,
and IEC5 950, TS0016 , AS/NZS7 3260

EMC 8

FCC9 Part 15, Class A (CFR10 47) (USA), ICES11 -003 Class A (Canada), EN55022 Class A (Europe), CISPR2212 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI13 Class A (Japan) with UTP14


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI Class B (Japan) with FTP15 cables

1 CE = European Compliance

2 UL = Underwriters Laboratory

3 CSA = Canadian Standards Association

4 EN = European Norm

5 IEC = International Electrotechnical Commission

6 TS = technical specifications

7 AS/NZS = Australia Standards/New Zealand Standards

8 EMC = electromagnetic compatibility

9 FCC = U.S. Federal Communications Commission

10 CFR = Code of Federal Regulations

11 ICES = Interference-Causing Equipment Standard

12 CISPR = Comite International Special des Perturbation Radioelectriques

13 VCCI = Voluntary Control Council for Information Technology Equipment

14 UTP = unshielded twisted-pair

15 FTP = foil twisted-pair


Catalyst 4006 Switch Specifications

Table A-2 lists the Catalyst 4006 switch specifications.

Table A-2 Catalyst 4006 Switch Specifications 

Item
Specification
Environmental
   

Temperature,
ambient operating
ambient nonoperating and storage


32 to 104°F (0 to 40°C)
-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing): operating
nonoperating and storage


10 to 90%
5 to 95%

Altitude:
operating
nonoperating


-500 to 6,500 ft. (-150 to 2000 m)
-1000 to 30,000 ft. (-300 to 9150 m)

Switching Components
 

Backplane

32-Gbps full duplex

Microprocessor

Supervisor engine: 150-MHz R5000 RISC

Memory
 

Supervisor engine

SDRAM: 64-MB DIMM (2Mx4x72, 168-pin, 100-MHz, nonregistered, 3.3 V), 16-MB Flash, 1-MB NVRAM

Physical Characteristics
   

Dimensions (H x W x D)

15.75 x 17.25 x 11.81 in. (40 x 43.7 x 30 cm)

Weight

Minimum weight: 31 lb (14.0 kg)
Maximum weight: 61 lb (27.7 kg)

400 W AC Power Supply
   

Power supply output capacity

400 W maximum per power supply; 725 W maximum with two power supplies

Power supply output current

+12 V @ 33.3 A (maximum) per power supply

AC-input voltage

100 to 240 VAC

AC frequency

50 to 60 Hz

AC-input current

6.0 A maximum @ 100 VAC 60 Hz per power supply; 3.0 A maximum @ 240 VAC 50 Hz per power supply

KVA rating

0.58 KVA

 

Heat dissipation

725 W maximum (3090 Btus per hour)

400 W DC Power Supply
   

Power supply output current

+12 V @ 33.3 A (maximum) per power supply

DC-input voltage

-48 to -60 VDC per power supply

DC-input current

11 A per power supply

KVA rating

0.53 KVA

 

Heat dissipation

530 W maximum (1800 Btus per hour)

Input terminal block

The terminal block accepts 22-12 AWG copper conductors. The installer or local electrician must determine the actual size of the wire. The terminal block material is rated at 105°C.

650W DC Power Supply
   

Power supply output current

+12 V @ 55.09 A (maximum) per power supply

DC-input voltage

-48 to -60 VDC per power supply

DC-input current

18 A per power supply

KVA rating

0.866 KVA

 

Heat dissipation

866.66 W maximum (2957.91 Btus per hour)

Input terminal block

The terminal block accepts 22-12 AWG copper conductors. The installer or local electrician must determine the actual size of the wire. The terminal block material is rated at 95°C.

Airflow
 

Switch

Right to left

 

Power supply

Front to back

 
Standards Compliance
   
Compliance

CE1 Marking

Safety

UL2 1950, CSA3 -C22.2 No. 950, EN4 60950,
and IEC5 950, TS0016 , AS/NZS7 3260

EMC 8

FCC9 Part 15, Class A (CFR10 47) (USA), ICES11 -003 Class A (Canada), EN55022 Class A (Europe), CISPR2212 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI13 Class A (Japan) with UTP14


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI Class B (Japan) with FTP15 cables

1 CE = European Compliance

2 UL = Underwriters Laboratory

3 CSA = Canadian Standards Association

4 EN = European Norm

5 IEC = International Electrotechnical Commission

6 TS = technical specifications

7 AS/NZS = Australia Standards/New Zealand Standards

8 EMC = electromagnetic compatibility

9 FCC = U.S. Federal Communications Commission

10 CFR = Code of Federal Regulations

11 ICES = Interference-Causing Equipment Standard

12 CISPR = Comite International Special des Perturbation Radioelectriques

13 VCCI = Voluntary Control Council for Information Technology Equipment

14 UTP = unshielded twisted-pair

15 FTP = foil twisted-pair