Catalyst 3550 Multilayer Switch Software Configuration Guide, 12.1(9)EA1
Configuring Interface Characteristics
Downloads: This chapterpdf (PDF - 379.0KB) The complete bookPDF (PDF - 10.01MB) | Feedback

Configuring Interface Characteristics

Table Of Contents

Configuring Interface Characteristics

Understanding Interface Types

Port-Based VLANs

Switch Ports

Access Ports

Trunk Ports

Tunnel Ports

EtherChannel Port Groups

Switch Virtual Interfaces

Routed Ports

Connecting Interfaces

Using the Interface Command

Procedures for Configuring Interfaces

Configuring a Range of Interfaces

Configuring and Using Interface Range Macros

Configuring Layer 2 Interfaces

Default Layer 2 Ethernet Interface Configuration

Configuring Interface Speed and Duplex Mode

Configuration Guidelines

Setting the Interface Speed and Duplex Parameters

Configuring IEEE 802.3X Flow Control

Adding a Description for an Interface

Monitoring and Maintaining the Layer 2 Interface

Monitoring Interface and Controller Status

Clearing and Resetting Interfaces and Counters

Shutting Down and Restarting the Interface

Configuring Layer 3 Interfaces


Configuring Interface Characteristics


This chapter defines the types of interfaces on the switch and describes how to configure them. The chapter has these sections:

Understanding Interface Types

Using the Interface Command

Configuring Layer 2 Interfaces

Monitoring and Maintaining the Layer 2 Interface

Configuring Layer 3 Interfaces


Note For complete syntax and usage information for the commands used in this chapter, refer to the Catalyst 3550 Multilayer Switch Command Reference for this release and the online Cisco IOS Interface Command Reference for Release 12.1.


Understanding Interface Types

This section describe the different types of interfaces supported by the switch with references to chapters that contain more detailed information about configuring these interface types. The rest of the chapter describes configuration procedures for physical interface characteristics.

These sections are included:

Port-Based VLANs

Switch Ports

EtherChannel Port Groups

Switch Virtual Interfaces

Routed Ports

Connecting Interfaces

Port-Based VLANs

A VLAN is a switched network that is logically segmented by function, team, or application, without regard to the physical location of the users. For more information about VLANs, see "Configuring VLANs." Packets received on a port are forwarded only to ports that belong to the same VLAN as the receiving port. Network devices in different VLANs cannot communicate with one another without a Layer 3 device to route traffic between the VLANs.

VLAN partitions provide hard firewalls for traffic in the VLAN, and each VLAN has its own MAC address table. A VLAN comes into existence when a local port is configured to be associated with the VLAN, when the VLAN Trunking Protocol (VTP) learns of its existence from a neighbor on a trunk, or when a user creates a VLAN.

To configure normal-range VLANs (VLAN IDs 1 to 1005), use the vlan vlan-id global configuration command to enter config-vlan mode or the vlan database privileged EXEC command to enter VLAN configuration mode. The VLAN configurations for VLAN IDs 1 to 1005 are saved in the VLAN database. To configure extended-range VLANs (VLAN IDs 1006 to 4094), you must use config-vlan mode with VTP mode set to transparent. Extended-range VLANs are not added to the VLAN database. When VTP mode is transparent, the VTP and VLAN configuration is saved in the switch running configuration, and you can save it in the switch startup configuration file by entering the copy running-config startup-config privileged EXEC command.

Add ports to a VLAN by using the switchport interface configuration commands:

Identify the interface.

For a trunk port, set trunk characteristics, and if desired, define the VLANs to which it can belong.

For an access port, set and define the VLAN to which it belongs.

For a tunnel port, set and define the VLAN ID for the customer-specific VLAN tag. See "Configuring 802.1Q and Layer 2 Protocol Tunneling."

Switch Ports

Switch ports are Layer 2-only interfaces associated with a physical port. A switch port can be an access port, a trunk port, or a tunnel port. You can configure a port as an access port or trunk port or let the Dynamic Trunking Protocol (DTP) operate on a per-port basis to determine if a switch port should be an access port or a trunk port by negotiating with the port on the other end of the link. You must manually configure tunnel ports as part of an asymmetric link connected to an 802.1Q trunk port. Switch ports are used for managing the physical interface and associated Layer 2 protocols and do not handle routing or bridging.

Configure switch ports by using the switchport interface configuration commands. For detailed information about configuring access ports and trunk ports, see "Configuring VLANs." For more information about tunnel ports, see "Configuring 802.1Q and Layer 2 Protocol Tunneling."

Access Ports

An access port carries the traffic of and belongs to only one VLAN. Traffic is received and sent in native formats with no VLAN tagging. Traffic arriving on an access port is assumed to belong to the VLAN assigned to the port. If an access port receives a tagged packet (Inter-Switch Link [ISL] or 802.1Q tagged), the packet is dropped, the source address is not learned, and the frame is counted in the No destination statistic.

Two types of access ports are supported:

Static access ports are manually assigned to a VLAN.

VLAN membership of dynamic access ports is learned through incoming packets. By default, a dynamic access port is a member of no VLAN, and forwarding to and from the port is enabled only when the VLAN membership of the port is discovered. In the Catalyst 3550 switch, dynamic access ports are assigned to a VLAN by a VLAN Membership Policy Server (VMPS). The VMPS can be a Catalyst 6000 series switch; the Catalyst 3550 switch does not support the function of a VMPS.

Trunk Ports

A trunk port carries the traffic of multiple VLANs and by default is a member of all VLANs in the VLAN database. Two types of trunk ports are supported:

In an ISL trunk port, all received packets are expected to be encapsulated with an ISL header, and all transmitted packets are sent with an ISL header. Native (non-tagged) frames received from an ISL trunk port are dropped.

An IEEE 802.1Q trunk port supports simultaneous tagged and untagged traffic. An 802.1Q trunk port is assigned a default Port VLAN ID (PVID), and all untagged traffic travels on the port default PVID. All untagged traffic and tagged traffic with a NULL VLAN ID are assumed to belong to the port default PVID. A packet with a VLAN ID equal to the outgoing port default PVID is sent untagged. All other traffic is sent with a VLAN tag.

Although by default, a trunk port is a member of every VLAN known to the VTP, you can limit VLAN membership by configuring an allowed list of VLANs for each trunk port. The list of allowed VLANs does not affect any other port but the associated trunk port. By default, all possible VLANs (VLAN ID 1 to 4094) are in the allowed list. A trunk port can only become a member of a VLAN if VTP knows of the VLAN and the VLAN is in the enabled state. If VTP learns of a new, enabled VLAN and the VLAN is in the allowed list for a trunk port, the trunk port automatically becomes a member of that VLAN and traffic is forwarded to and from the trunk port for that VLAN. If VTP learns of a new, enabled VLAN that is not in the allowed list for a trunk port, the port does not become a member of the VLAN, and no traffic for the VLAN is forwarded to or from the port.


Note VLAN 1 cannot be excluded from the allowed list.


For more information about trunk ports, see "Configuring VLANs."

Tunnel Ports

Tunnel ports are used in 802.1Q tunneling to segregate the traffic of customers in a service provider network from other customers who appear to be on the same VLAN. You configure an asymmetric link from a tunnel port on a service provider edge switch to an 802.1Q trunk port on the customer switch. Packets entering the tunnel port on the edge switch, already 802.1Q-tagged with the customer VLANs, are encapsulated with another layer of 802.1Q tag (called the metro tag) containing a VLAN ID unique in the service provider network, for each customer. The double-tagged packets go through the service-provider network keeping the original customer VLANs separate from those of other customers. At the outbound interface, also a tunnel port, the metro tag is removed, and the original VLAN numbers from the customer network are retrieved.

Tunnel ports cannot be trunk ports or access ports and must belong to a VLAN unique for each customer.

For more information about tunnel ports, see "Configuring 802.1Q and Layer 2 Protocol Tunneling."

EtherChannel Port Groups

EtherChannel port groups provide the ability to treat multiple switch ports as one switch port. These port groups act as a single logical port for high-bandwidth connections between switches or between switches and servers. An EtherChannel balances the traffic load across the links in the channel. If a link within the EtherChannel fails, traffic previously carried over the failed link changes to the remaining links. You can group multiple trunk ports into one logical trunk port, group multiple access ports into one logical access port, or group multiple tunnel ports into one logical tunnel port. Most protocols operate over either single ports or aggregated switch ports and do not recognize the physical ports within the port group. Exceptions are the DTP, the Cisco Discovery Protocol (CDP), and the Port Aggregation Protocol (PAgP), which operate only on physical ports.

When you configure an EtherChannel, you create a port-channel logical interface and assign an interface to the EtherChannel. For Layer 3 interfaces, you manually create the logical interface by using the interface port-channel global configuration command. For Layer 2 interfaces, the logical interface is dynamically created. For both Layer 3 and 2 interfaces, you manually assign an interface to the EtherChannel by using the channel-group interface configuration command. This command binds the physical and logical ports together. For more information, see "Configuring EtherChannels."

Switch Virtual Interfaces

A switch virtual interface (SVI) represents a VLAN of switch ports as one interface to the routing or bridging function in the system. Only one SVI can be associated with a VLAN, but you need to configure an SVI for a VLAN only when you wish to route between VLANs, fallback-bridge nonroutable protocols between VLANs, or to provide IP host connectivity to the switch. By default, an SVI is created for the default VLAN (VLAN 1) to permit remote switch administration. Additional SVIs must be explicitly configured. In Layer 2 mode, SVIs provide IP host connectivity only to the system; in Layer 3 mode, you can configure routing across SVIs.


Note To use SVIs in Layer 3 mode, you must have the enhanced multilayer software image (EMI) installed on your switch. All Catalyst 3550 Gigabit Ethernet switches ship with the EMI installed. Catalyst 3550 Fast Ethernet switches can be shipped with either the standard multilayer software image (SMI) or EMI pre-installed. You can order the Enhanced Multilayer Software Image Upgrade kit to upgrade Catalyst 3550 Fast Ethernet switches from the SMI to the EMI.


SVIs are created the first time that you enter the vlan interface configuration command for a VLAN interface. The VLAN corresponds to the VLAN tag associated with data frames on an ISL or 802.1Q encapsulated trunk or the VLAN ID configured for an access port. Configure a VLAN interface for each VLAN for which you want to route traffic, and assign it an IP address. For more information, see the "Configuring IP Addressing" section.

SVIs support routing protocol and bridging configurations. For more information about configuring IP routing, see "Configuring IP Unicast Routing," "Configuring IP Multicast Routing,"and "Configuring Fallback Bridging."

Routed Ports

A routed port is a physical port that acts like a port on a router; it does not have to be connected to a router. A routed port is not associated with a particular VLAN, as is an access port. A routed port behaves like a regular router interface, except that it does not support VLAN subinterfaces. Routed ports can be configured with a Layer 3 routing protocol.


Note To configure routed ports, you must have the EMI installed on your switch.


Configure routed ports by putting the interface into Layer 3 mode with the no switchport interface configuration command. Then assign an IP address to the port, enable routing, and assign routing protocol characteristics by using the ip routing and router protocol global configuration commands.


Caution Entering a no switchport interface configuration command shuts the interface down and then re-enables it, which might generate messages on the device to which the interface is connected. Furthermore, when you use this command to put the interface into Layer 3 mode, you are deleting any Layer 2 characteristics configured on the interface.

The number of routed ports and SVIs that you can configure is not limited by software; however, the interrelationship between this number and the number of other features being configured might have an impact on CPU utilization because of hardware limitations. For more information about feature combinations, see the "Optimizing System Resources for User-Selected Features" section.

For more information about IP unicast and multicast routing and routing protocols, see "Configuring IP Unicast Routing" and "Configuring IP Multicast Routing."

Connecting Interfaces

Devices within a single VLAN can communicate directly through any switch. Ports in different VLANs cannot exchange data without going through a routing device or routed interface.

With a standard Layer 2 switch, ports in different VLANs have to exchange information through a router. In the configuration shown in Figure 9-1, when Host A in VLAN 20 sends data to Host B in VLAN 30, it must go from Host A to the switch, to the router, back to the switch, and then to Host B.

Figure 9-1 Connecting VLANs with Layer 2 Switches

By using the Catalyst 3550 with the enhanced multilayer software image installed, when you configure VLAN 20 and VLAN 30 each with an SVI to which an IP address is assigned, packets can be sent from Host A to Host B directly through the Catalyst 3550 switch with no need for an external router (Figure 9-2).

Figure 9-2 Connecting VLANs with the Catalyst 3550 Multilayer Switch

The Catalyst 3550 switch with the enhanced multilayer software image supports two methods of forwarding traffic between interfaces: routing and fallback bridging. Whenever possible, to maintain high performance, forwarding is done by switch hardware. However, only IP version 4 packets with Ethernet II encapsulation can be routed in hardware. All other types of traffic can be fallback bridged by hardware.

The routing function can be enabled on all SVIs and routed ports. The Catalyst 3550 switches with the enhanced multilayer software image route only IP traffic. When IP routing protocol parameters and address configuration are added to an SVI or routed port, any IP traffic received from these ports is routed. For more information, see "Configuring IP Unicast Routing,"
"Configuring IP Multicast Routing," and "Configuring MSDP."

Fallback bridging forwards traffic that the switch with the enhanced multilayer software image does not route or traffic belonging to a nonroutable protocol, such as DECnet. Fallback bridging connects multiple VLANs into one bridge domain by bridging between two or more SVIs or routed ports. When configuring fallback bridging, you assign SVIs or routed ports to bridge groups with each SVI or routed port assigned to only one bridge group. All interfaces in the same group belong to the same bridge domain. For more information, see "Configuring Fallback Bridging."

Using the Interface Command

The Catalyst 3550 switch supports these interface types:

Physical ports—including switch ports and routed ports

VLANs—Switch Virtual Interfaces

Port-channels—EtherChannel of interfaces

You can also configure a range of interfaces (see the "Configuring a Range of Interfaces" section).

To configure a physical interface (port), enter interface configuration mode, and specify the interface type, slot, and number.

TypeFast Ethernet (fastethernet or fa) for 10/100 Ethernet or Gigabit Ethernet (gigabitethernet or gi)

SlotThe slot number on the switch. On the Catalyst 3550 switch, the slot number is 0.

Port number—The interface number on the switch. The port numbers always begin at 1, starting at the left when facing the front of the switch, for example, gigabitethernet 0/1, gigabitethernet 0/2. If there is more than one media type (for example, 10/100 ports and Gigabit Ethernet ports), the port number starts again with the second media: fastethernet0/1, fastethernet0/2.

You can identify physical interfaces by physically checking the interface location on the switch. You can also use the IOS show privileged EXEC commands to display information about a specific interface or all the interfaces on the switch. The remainder of this chapter primarily provides physical interface configuration procedures.

Procedures for Configuring Interfaces

These general instructions apply to all interface configuration processes.


Step 1 Enter the configure terminal command at the privileged EXEC prompt:

Switch# configure terminal 
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)# 

Step 2 Enter the interface global configuration command. Identify the interface type and the number of the connector. In this example, Gigabit Ethernet interface 0/1 is selected:

Switch(config)# interface gigabitethernet0/1 
Switch(config-if)# 

Note You do not need to add a space between the interface type and interface number. For example, in the preceding line, you can specify either gigabitethernet 0/1, gigabitethernet0/1, gi 0/1, or gi0/1.


Step 3 Follow each interface command with the interface configuration commands your particular interface requires. The commands you enter define the protocols and applications that will run on the interface. The commands are collected and applied to the interface when you enter another interface command or enter end to return to privileged EXEC mode.

You can also configure a range of interfaces by using the interface range or interface range macro global configuration commands. Interfaces configured in a range must be the same type and must be configured with the same feature options.

Step 4 After you configure an interface, verify its status by using the show privileged EXEC commands listed in the "Monitoring and Maintaining the Layer 2 Interface" section.


Enter the show interfaces privileged EXEC command to see a list of all interfaces on or configured for the switch. A report is provided for each interface that the device supports or for the specified interface:

Switch# show interfaces
Vlan1 is up, line protocol is up
  Hardware is EtherSVI, address is 0000.0000.0000 (bia 0000.0000.00
  Internet address is 10.1.1.64/24
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:35, output 2d14h, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 1 drops; input queue 0/75, 0 drops
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     264251 packets input, 163850228 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     380 packets output, 26796 bytes, 0 underruns
     0 output errors, 0 interface resets
     0 output buffer failures, 0 output buffers swapped out
FastEthernet0/1 is up, line protocol is down
  Hardware is Fast Ethernet, address is 0000.0000.0001 (bia 0000.00
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Auto-duplex, Auto-speed
  input flow-control is off, output flow-control is off
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input never, output never, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 2 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out

<output truncated>

Configuring a Range of Interfaces

You can use the interface range global configuration command to configure multiple interfaces with the same configuration parameters. When you enter the interface range configuration mode, all command parameters that you enter are attributed to all interfaces within that range until you exit this mode.

Beginning in privileged EXEC mode, follow these steps to configure a range of interfaces with the same parameters:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode.

Step 2 

interface range {port-range | macro macro_name}

Enter interface range configuration mode by entering the range of interfaces (VLANs or physical ports) to be configured.

You can use the interface range command to configure up to five port ranges or a previously defined macro.

The macro variable is explained in the "Configuring and Using Interface Range Macros" section.

Each comma-separated port-range must consist of the same port type. You do not need to enter spaces before or after the comma.

When you define a range, the space between the first port and the hyphen is required.

Step 3 

 

You can now use the normal configuration commands to apply the configuration parameters to all interfaces in the range.

Step 4 

end

Return to privileged EXEC mode.

Step 5 

show interfaces [interface-id]

Verify the configuration of the interfaces in the range.

Step 6 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

When using the interface range global configuration command, note these guidelines:

Valid entries for port-range:

vlan vlan-ID - vlan-ID, where VLAN ID is from 1 to 4094

fastethernet slot/{first port} - {last port}, where slot is 0

gigabitethernet slot/{first port} - {last port}, where slot is 0

port-channel port-channel-number - port-channel-number, where port-channel-number is from 1 to 64

You must add a space between the interface numbers and the hyphen when using the interface range command. For example, the command interface range gigabitethernet 0/1 - 5 is a valid range; the command interface range gigabitethernet 0/1-5 is not a valid range.

The interface range command works only with VLAN interfaces that have been configured with the interface vlan command (the show running-config privileged EXEC command displays the configured VLAN interfaces). VLAN interfaces not displayed by the show running-config command cannot be used with the interface range command.

All interfaces in a range must be the same type; that is, all Fast Ethernet ports, all Gigabit Ethernet ports, all EtherChannel ports, or all SVIs.

This example shows how to use the interface range global configuration command to enable Gigabit Ethernet interfaces 0/1 to 0/5:

Switch# configure terminal
Switch(config)# interface range gigabitethernet0/1 - 5 
Switch(config-if-range)# no shutdown 
Switch(config-if-range)#
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface GigabitEthernet0/4, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface GigabitEthernet0/5, changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/05, 
changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, 
changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/4, 
changed state to up

This example shows how to use a comma to add different interface type strings to the range to enable all Gigabit Ethernet interfaces in the range 0/1 to 0/3 and both Gigabit Ethernet interfaces 0/7 and 0/8:

Switch# configure terminal
Switch(config)# interface range gigabitethernet0/1 - 3, gigabitethernet0/7 - 8 
Switch(config-if-range)# no shutdown 
Switch(config-if-range)#
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/7, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/8, changed state to up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/ 7, 
changed state to up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/ 2, 
changed state to up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/ 4, 
changed state to up

If you enter multiple configuration commands while you are in interface range mode, each command is executed as it is entered. The commands are not batched together and executed after you exit interface range mode. If you exit interface range configuration mode while the commands are being executed, some commands might not be executed on all interfaces in the range. Wait until the command prompt reappears before exiting interface range configuration mode.

Configuring and Using Interface Range Macros

You can create an interface range macro to automatically select a range of interfaces for configuration. Before you can use the macro keyword in the interface range macro global configuration command string, you must use the define interface-range global configuration command to define the macro.

Beginning in privileged EXEC mode, follow these steps to define an interface range macro:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode.

Step 2 

define interface-range macro_name interface-range

Define the interface-range macro, and save it in NVRAM.

The macro_name is a 32-character maximum character string.

A macro can contain up to five comma-separated interface ranges. You do not need to enter spaces before or after the comma.

Each interface-range must consist of the same port type.

Step 3 

interface range macro macro_name

Select the interface range to be configured using the values saved in the interface-range macro called macro_name.

You can now use the normal configuration commands to apply the configuration to all interfaces in the defined macro.

Step 4 

end

Return to privileged EXEC mode.

Step 5 

show running-config | include define

Show the defined interface range macro configuration.

Step 6 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

Use the no define interface-range macro_name global configuration command to delete a macro.

When using the define interface-range global configuration command, note these guidelines:

Valid entries for interface-range:

vlan vlan-ID - vlan-ID, where VLAN ID is from 1 to 4094

fastethernet slot/{first port} - {last port}, where slot is 0

gigabitethernet slot/{first port} - {last port}, where slot is 0

port-channel port-channel-number - port-channel-number, where port-channel-number is from 1 to 64.

You must add a space between the interface numbers and the hyphen when entering an interface-range. For example, gigabitethernet 0/1 - 5 is a valid range; gigabitethernet 0/1-5 is not a valid range.

The VLAN interfaces (SVIs) must have been configured with the interface vlan command. The show running-config privileged EXEC command displays the configured VLAN interfaces. VLAN interfaces not displayed by the show running-config command cannot be used as interface-ranges.

All interfaces in a range must be the same type; that is, all Fast Ethernet ports, all Gigabit Ethernet ports, all EtherChannel ports, or all VLANs, but you can combine multiple interface types in a macro.

This example shows how to define an interface-range macro named enet_list to select Gigabit Ethernet ports 1 to 4 and to verify the macro configuration:

Switch# configure terminal
Switch(config)# define interface-range enet_list gigabitethernet0/1 - 4 
Switch(config)# end
Switch# show running-config | include define 
define interface-range enet_list GigabitEthernet0/1 - 4
Switch#

This example shows how to create a multiple-interface macro named macro1:

Switch# configure terminal
Switch(config)# define interface-range macro1 gigabitethernet0/1 - 2, fastethernet0/5 - 7
Switch(config)# end
Switch# 

This example shows how to enter interface range configuration mode for the interface-range macro enet_list:

Switch# configure terminal
Switch(config)# interface range macro enet_list 
Switch(config-if-range)# 

This example shows how to delete the interface-range macro enet_list and to verify that it has been deleted.

Switch# configure terminal
Switch(config)# no define interface-range enet_list 
Switch# show run | include define
Switch#

Configuring Layer 2 Interfaces

These sections describe the default interface configuration and the optional features that you can configure on most physical interfaces:

Default Layer 2 Ethernet Interface Configuration

Configuring Interface Speed and Duplex Mode

Configuring IEEE 802.3X Flow Control

Adding a Description for an Interface


Caution If the interface is in Layer 3 mode, after entering interface configuration mode, you must enter the switchport interface configuration command without any parameters to put the interface into Layer 2 mode. This shuts down the interface and then re-enables it, which might generate messages on the device to which the interface is connected. Furthermore, when you use this command to put the interface into Layer 2 mode, you are deleting any Layer 3 characteristics configured on the interface.

Default Layer 2 Ethernet Interface Configuration

Table 9-1 shows the Layer 2 Ethernet interface default configuration. For more details on the VLAN parameters listed in the table, see "Configuring VLANs." For details on controlling traffic to the port, see "Configuring Port-Based Traffic Control."

Table 9-1 Default Layer 2 Ethernet Interface Configuration 

Feature
Default Setting

Operating mode

Layer 2 or switching mode (switchport command).

Note Routing mode (no switchport command) is only an option when the enhanced multilayer software image is installed. All Catalyst 3550 Gigabit Ethernet switches ship with the EMI installed. Catalyst 3550 Fast Ethernet switches can be shipped with either SMI or EMI pre-installed. You can order the Enhanced Multilayer Software Image Upgrade kit to upgrade Catalyst 3550 Fast Ethernet switches from the SMI to the EMI.

Allowed VLAN range

VLANs 1 - 4094.

Default VLAN (for access ports)

VLAN 1.

Native VLAN (for 802.1Q trunks)

VLAN 1.

VLAN trunking

Switchport mode dynamic desirable (supports DTP).

Port enable state

All ports are enabled.

Port description

None defined.

Speed

Autonegotiate.

Duplex mode

Autonegotiate.

Flow control

Flow control set to off for receive and desired for send for 10/100/1000 Mb/s. For 10/100 Mb/s ports, send is always off.

EtherChannel (PAgP)

Disabled on all Ethernet ports. See "Configuring EtherChannels."

Port blocking (unknown multicast and unknown unicast traffic)

Disabled (not blocked). See the "Configuring Port Blocking" section.

Broadcast, multicast, and unicast storm control

Disabled. See the "Default Storm Control Configuration" section.

Protected port

Disabled. See the "Configuring Protected Ports" section.

Port security

Disabled. See the "Default Port Security Configuration" section.

Port Fast

Disabled.


Configuring Interface Speed and Duplex Mode

These sections describe how to configure the interface speed and duplex mode:

Configuration Guidelines

Setting the Interface Speed and Duplex Parameters

Configuration Guidelines

When configuring an interface speed and duplex mode, note these guidelines:

If both ends of the line support autonegotiation, we highly recommend the default autonegotiation settings.

If one interface supports autonegotiation and the other end does not, configure duplex and speed on both interfaces; do not use the auto setting on the supported side.


Note GigaStack-to-GigaStack cascade connections operate in half-duplex mode, and GigaStack-to-GigaStack point-to-point connections operate in full-duplex mode.



Caution Changing the interface speed and duplex mode configuration might shut down and re-enable the interface during the reconfiguration.

Setting the Interface Speed and Duplex Parameters

You can configure interface speed on Fast Ethernet (10/100-Mbps) and Gigabit Ethernet (10/100/1000-Mbps) interfaces; you cannot configure speed on Gigabit Interface Converter (GBIC) interfaces. You can configure duplex mode on any Fast Ethernet or Gigabit Ethernet interfaces that are not set to autonegotiate; you cannot configure duplex mode on GBIC interfaces. Because collisions are major constrictions in Ethernet networks, full-duplex communication is an effective solution. Normally, 10-Mbps ports operate in half-duplex mode, which means that stations can either receive or send. In full-duplex mode, two stations can send and receive at the same time. When packets can flow in both directions simultaneously, effective Ethernet bandwidth doubles to 20 Mbps for 10-Mbps interfaces, to 200 Mbps for Fast Ethernet interfaces, and to 2 Gbps for Gigabit interfaces.


Note You cannot configure speed or duplex mode on Gigabit Interface Converter (GBIC) ports, but for certain types of GBICs, you can configure speed to not negotiate (nonegotiate) if connected to a device that does not support autonegotiation.


Beginning in privileged EXEC mode, follow these steps to set the speed and duplex mode for a physical interface:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode.

Step 2 

interface interface-id

Enter interface configuration mode and the physical interface identification.

Step 3 

speed {10 | 100 | 1000 | auto | nonegotiate}

Enter the appropriate speed parameter for the interface, or enter auto or nonegotiate.

Note The 1000 keyword is available only for 10/100/1000 Mbps ports. The nonegotiate keyword is available only for 1000BASE-SX, -LX, and -ZX GBIC ports.

Step 4 

duplex {auto | full | half}

Enter the duplex parameter for the interface.

Step 5 

end

Return to privileged EXEC mode.

Step 6 

show interfaces interface-id

Display the interface speed and duplex mode configuration.

Step 7 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

Use the no speed and no duplex interface configuration commands to return the interface to the default speed and duplex settings (autonegotiate). To return all interface settings to the defaults, use the default interface interface-id interface configuration command.

This example shows how to set the interface speed to 10 Mbps and the duplex mode to half on FastEthernet interface 0/3 and to verify the configuration:

Switch# configure terminal
Switch(config)# interface fastethernet0/3
Switch(config-if)# speed 10
Switch(config-if)# duplex half
Switch(config-if)# end
Switch# show interfaces fastethernet0/3
FastEthernet0/3 is up, line protocol is down
  Hardware is Fast Ethernet, address is 0000.0000.0003 (bia 0000.0000.0003)
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Half-duplex, 10Mb/s

<output truncated>

Configuring IEEE 802.3X Flow Control

Flow control enables connected Ethernet ports to control traffic rates during congestion by allowing congested nodes to pause link operation at the other end. If one port experiences congestion and cannot receive any more traffic, it notifies the other port to stop sending until the condition clears. When the local device detects any congestion at its end, it can notify the link partner or the remote device of the congestion by sending a pause frame. Upon receipt of a pause frame, the remote device stops sending any data packets, which prevents any loss of data packets during the congestion period.


Note You must not configure both IEEE 802.3X flowcontrol and quality of service (QoS) on a switch. Before configuring flowcontrol on an interface, use the no mls qos global configuration command to disable QoS on the switch.


Flow control can be implemented in two forms, symmetric and asymmetric. The symmetric implementation is suitable for point-to-point links, and asymmetric is suitable for hub-to-end node connections, where it is desirable for the hub to pause the end system, but not vice-versa. You use the flowcontrol interface configuration command to set the interface's ability to receive and send pause frames to on, off, or desired. The default state for Gigabit Ethernet ports is receive off and send desired. The default state for Fast Ethernet ports is receive off and send off.


Note On Catalyst 3550 switches, Gigabit Ethernet ports are capable of receiving and sending pause frames; Fast Ethernet ports can only receive pause frames. Therefore, for Fast Ethernet ports, only the conditions described with send off are applicable.


These rules apply to flow control settings on the device:

receive on (or desired) and send on: Flow control operates in both directions; both the local and the remote devices can send pause frames to show link congestion.

receive on (or desired) and send desired: The port can receive pause frames and can send pause frames if the attached device supports flow control.

receive on (or desired) and send off: The port cannot send pause frames but can operate with an attached device that is required to or can send pause frames; the port can receive pause frames.

receive off and send on: The port sends pause frames if the remote device supports flow control but cannot receive pause frames from the remote device.

receive off and send desired: The port cannot receive pause frames but can send pause frames if the attached device supports flow control.

receive off and send off: Flow control does not operate in either direction. In case of congestion, no indication is given to the link partner, and no pause frames are sent or received by either device.


Note For details on the command settings and the resulting flow control resolution on local and remote ports, refer to the flowcontrol interface configuration command in the Catalyst 3550 Multilayer Switch Command Reference for this release.


Beginning in privileged EXEC mode, follow these steps to configure flow control on an interface:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode

Step 2 

no mls qos

Disable QoS on the switch.

Step 3 

interface interface-id

Enter interface configuration mode and the physical interface to be configured.

Step 4 

flowcontrol {receive | send} {on | off | desired}

Configure the flow control mode for the port.

Note The send keyword is not available for 10/100 Mbps ports.

Step 5 

end

Return to privileged EXEC mode.

Step 6 

show interfaces interface-id

Verify the interface flow control settings.

Step 7 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

To disable flow control, use the flowcontrol receive off and flowcontrol send off interface configuration commands.

This example shows how to turn off all flow control on Gigabit Ethernet interface 0/1 and to display the results:

Switch# configure terminal
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# flowcontrol receive off
Switch(config-if)# flowcontrol send off
Switch(config-if)# end
Switch# show interfaces gigabitethernet0/1
GigabitEthernet0/1 is up, line protocol is down
  Hardware is Gigabit Ethernet, address is 0002.4b29.2e01 (bia 0002.4b29.2e01)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Auto-duplex, Auto-speed
  input flow-control is off, output flow-control is off
<output truncated>

Adding a Description for an Interface

You can add a description about an interface to help you remember its function. The description appears in the output of these commands: show configuration, show running-config, and show interfaces.

Beginning in privileged EXEC mode, follow these steps to add a description for an interface:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode

Step 2 

interface interface-id

Enter interface configuration mode, and enter the interface for which you are adding a description.

Step 3 

description string

Add a description (up to 240 characters) for an interface.

Step 4 

end

Return to privileged EXEC mode.

Step 5 

show interfaces interface-id description

or

show running-config

Verify your entry.

Step 6 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

Use the no description interface configuration command to delete the description.

This example shows how to add a description on Fast Ethernet interface 0/4 and to verify the description:

Switch# config terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)# interface fastethernet0/4
Switch(config-if)# description Connects to Marketing
Switch(config-if)# end
Switch# show interfaces fastethernet0/4 description
Interface Status         Protocol Description
Fa0/4     up             down     Connects to Marketing

Monitoring and Maintaining the Layer 2 Interface

You can perform the tasks in these sections to monitor and maintain the interfaces:

Monitoring Interface and Controller Status

Clearing and Resetting Interfaces and Counters

Shutting Down and Restarting the Interface

Monitoring Interface and Controller Status

Commands entered at the privileged EXEC prompt display information about the interface, including the version of the software and the hardware, the controller status, and statistics about the interfaces. Table 9-2 lists some of these interface monitoring commands. (You can display the full list of show commands by using the show ? command at the privileged EXEC prompt.) These commands are fully described in the Cisco IOS Interface Command Reference for Release 12.1.

Table 9-2 Show Commands for Interfaces 

Command
Purpose

show interfaces [interface-id]

Display the status and configuration of all interfaces or a specific interface.

show interfaces interface-id status [err-disabled]

Display interface status or a list of interfaces in error-disabled state.

show interfaces [interface-id] switchport

Display administrative and operational status of switching (nonrouting) ports. You can use this command to determine if a port is in routing or switching mode.

show interfaces [interface-id] description

Display the description configured on an interface or all interfaces and the interface status.

show running-config

Display the running configuration in RAM.

show version

Display the hardware configuration, software version, the names and sources of configuration files, and the boot images.


This example shows how to display the status of all interfaces:

Switch# show interfaces status

Port	Name	Status	Vlan	Duplex	Speed	Type
Gi0/1	CubeA	connected 	1	a-full 	a-100	10/100/1000BaseTX
Gi0/2	CubeE	notconnect	1	auto	auto	10/100/1000BaseTX
Gi0/3   	CubeF	disabled	1	auto	auto	10/100/1000BaseTX
Gi0/4 	CubeG	notconnect	1 	auto	auto	10/100/1000BaseTX
Gi0/5	CubeH	notconnect	routed 	auto	auto	10/100/1000BaseTX
Gi0/6 	CubeI	notconnect	routed	auto	auto	10/100/1000BaseTX
Gi0/7 	CubeJ 	connected 	1 	a-full	a-100	10/100/1000BaseTX
Gi0/8 	CubeK	notconnect	1 	auto	auto	10/100/1000BaseTX
Gi0/9	CubeL	disabled	1 	auto	auto	10/100/1000BaseTX
Gi0/10 	CubeB  	notconnect	routed 	auto	auto	10/100/1000BaseTX
Gi0/11	CubeC 	notconnect	1	auto	auto	unknown
Gi0/12	CubeD 	notconnect	1	auto	auto	unknown 

This example shows how to display the status of switching ports:

Switch# show interfaces switchport
Name: Gi0/1
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: static access
Administrative Trunking Encapsulation: negotiate
Operational Trunking Encapsulation: native
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

Protected: True
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled

Voice VLAN: none (Inactive)
Appliance trust: none

Name: Gi0/2
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: down
Administrative Trunking Encapsulation: negotiate
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

Protected: True
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled

Voice VLAN: none (Inactive)
Appliance trust: none

<output truncated>

Clearing and Resetting Interfaces and Counters

Table 9-3 lists the privileged EXEC mode clear commands that you can use to clear counters and reset interfaces.

Table 9-3 Clear Commands for Interfaces

Command
Purpose

clear counters [interface-id]

Clear interface counters.

clear interface interface-id

Reset the hardware logic on an interface.

clear line [number | console 0 | vty number]

Reset the hardware logic on an asynchronous serial line.


To clear the interface counters shown by the show interfaces privileged EXEC command, use the clear counters privileged EXEC command. The clear counters command clears all current interface counters from the interface unless optional arguments are specified to clear only a specific interface type from a specific interface number.


Note The clear counters privileged EXEC command does not clear counters retrieved by using Simple Network Management Protocol (SNMP), but only those seen with the show interface privileged EXEC command.


This example shows how to clear and reset the counters on Gigabit Ethernet interface 0/5:

Switch# clear counters gigabitethernet0/5 
Clear "show interface" counters on this interface [confirm] y 
Switch#
*Sep 30 08:42:55: %CLEAR-5-COUNTERS: Clear counter on interface GigabitEthernet0/5
by vty1 (171.69.115.10)

Use the clear interface or clear line privileged EXEC command to clear and reset an interface or serial line. Under most circumstances, you do not need to clear the hardware logic on interfaces or serial lines.

This example shows how to clear and reset Gigabit Ethernet interface 0/5:

Switch# clear interface gigabitethernet0/5 

Shutting Down and Restarting the Interface

Shutting down an interface disables all functions on the specified interface and marks the interface as unavailable on all monitoring command displays. This information is communicated to other network servers through all dynamic routing protocols. The interface is not mentioned in any routing updates.

Beginning in privileged EXEC mode, follow these steps to shut down an interface:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode.

Step 2 

interface {vlan vlan-id} | {{fastethernet | gigabitethernet} interface-id} | {port-channel port-channel-number}

Select the interface to be configured.

Step 3 

shutdown

Shut down an interface.

Step 4 

end

Return to privileged EXEC mode.

Step 5 

show running-config

Verify your entry.

Use the no shutdown interface configuration command to restart the interface.

This example shows how to shut down Gigabit Ethernet interface 0/5:

Switch# configure terminal
Switch(config)# interface gigabitethernet0/5 
Switch(config-if)# shutdown 
Switch(config-if)#
*Sep 30 08:33:47: %LINK-5-CHANGED: Interface GigabitEthernet0/5, changed state to a 
administratively down

This example shows how to re-enable Gigabit Ethernet interface 0/5:

Switch# configure terminal
Switch(config)# interface gigabitethernet0/5 
Switch(config-if)# no shutdown 
Switch(config-if)#
*Sep 30 08:36:00: %LINK-3-UPDOWN: Interface GiogabitEthernet0/5, changed state to up

To verify that an interface is disabled, enter the show interfaces privileged EXEC command. A disabled interface is shown as administratively down in the show interface command display as with Gigabit Ethernet interface 0/1 in this example.

Switch# show interfaces 
<output truncated>

GigabitEthernet0/2 is administratively down, line protocol is down
  Hardware is Gigabit Ethernet, address is 0002.4b29.4403 (bia 0002.4b29.4403)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Auto-duplex, Auto-speed

<output truncated>

Configuring Layer 3 Interfaces

The Catalyst 3550 with the enhanced multilayer software image supports three types of Layer 3 interfaces for routing and bridging:

SVIs: You should configure SVIs for any VLANs for which you want to route traffic. SVIs are created when you enter a VLAN ID following the interface vlan global configuration command. To delete an SVI, use the no interface vlan global configuration command.

For information about assigning Layer 2 ports to VLANs, see "Configuring VLANs."

Layer 3 EtherChannel ports: EtherChannel interfaces made up of routed ports.

EtherChannel port interfaces are described in "Configuring EtherChannels."

Routed ports: Routed ports are physical ports configured to be in Layer 3 mode by using the no switchport interface configuration command.


Note A Layer 3 switch can have an IP address assigned to each routed port and SVI. The number of routed ports and SVIs that you can configure is not limited by software; however, the interrelationship between this number and the number of other features being configured might have an impact on CPU utilization because of hardware limitations. For more information about feature combinations, see the "Optimizing System Resources for User-Selected Features" section.


All Layer 3 interfaces require an IP address to route traffic. The following procedure shows how to configure an interface as a Layer 3 interface and how to assign an IP addresses to an interface.


Note If the physical port is in Layer 2 mode (the default), you must enter the no switchport interface configuration command to put the interface into Layer 3 mode. Entering a no switchport command disables and then re-enables the interface, which might generate messages on the device to which the interface is connected. When you use this command to put the interface into Layer 3 mode, you are also deleting any Layer 2 characteristics configured on the interface.


Beginning in privileged EXEC mode, follow these steps to configure a Layer 3 interface:

 
Command
Purpose

Step 1 

configure terminal

Enter global configuration mode.

Step 2 

interface {{fastethernet | gigabitethernet} interface-id} | {vlan vlan-id} | {port-channel port-channel-number}

Enter interface configuration mode, and enter the interface to be configured as a Layer 3 interface.

Step 3 

no switchport

For physical ports only, enter Layer 3 mode.

Step 4 

ip address ip_address subnet_mask

Configure the IP address and IP subnet.

Step 5 

no shutdown

Enable the interface.

Step 6 

end

Return to privileged EXEC mode.

Step 7 

show interfaces [interface-id]

show ip interface [interface-id]

show running-config interface [interface-id]

Verify the configuration.

Step 8 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

To remove an IP address from an interface, use the no ip address interface configuration command.

This example shows how to configure an interface as a routed port and to assign it an IP address:

Switch# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# no switchport
Switch(config-if)# ip address 192.20.135.21 255.255.255.0
Switch(config-if)# no shutdown
Switch(config-if)# end 

This is an example of output from the show interfaces privileged EXEC command for an interface:

Switch(config)# show interfaces gigabitethernet0/2
GigabitEthernet0/2 is up, line protocol is up
  Hardware is Gigabit Ethernet, address is 0002.4b29.4400 (bia 0002.4b29.4400)
  Internet address is 192.20.135.21/24
  MTU 1500 bytes, BW 100000 Kbit, DLY 10 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s
  input flow-control is off, output flow-control is off
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:02, output 00:00:08, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     89604 packets input, 8480109 bytes, 0 no buffer
     Received 81848 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     60665 packets output, 6029820 bytes, 0 underruns
     0 output errors, 0 collisions, 16 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out 

This is an example of output from the show ip interface privileged EXEC command for an interface:

Switch# show ip interface gigabitethernet0/2
GigabitEthernet0/2 is up, line protocol is up
  Internet address is 192.20.135.21/24
  Broadcast address is 255.255.255.255
  Address determined by setup command
  MTU is 1500 bytes
  Helper address is not set
  Directed broadcast forwarding is disabled
  Multicast reserved groups joined: 224.0.0.5 224.0.0.6
  Outgoing access list is not set
  Inbound  access list is not set
  Proxy ARP is enabled
  Local Proxy ARP is disabled
  Security level is default
  Split horizon is enabled
  ICMP redirects are always sent
  ICMP unreachables are always sent
  ICMP mask replies are never sent
  IP fast switching is enabled
  IP fast switching on the same interface is disabled
  IP Flow switching is disabled
  IP CEF switching is enabled
  IP CEF Fast switching turbo vector
  IP multicast fast switching is enabled
  IP multicast distributed fast switching is disabled
  IP route-cache flags are Fast, CEF
  Router Discovery is disabled
  IP output packet accounting is disabled
  IP access violation accounting is disabled
  TCP/IP header compression is disabled
  RTP/IP header compression is disabled
  Probe proxy name replies are disabled
  Policy routing is disabled
  Network address translation is disabled
  WCCP Redirect outbound is disabled
  WCCP Redirect exclude is disabled
  BGP Policy Mapping is disabled 
 

These are examples of output for the show running-config privileged EXEC command for interfaces where different parameters are configured:

Switch# show running-config interface gigabitethernet0/2 
Building configuration...

Current configuration : 122 bytes
!
interface GigabitEthernet0/2
 no switchport
 ip address 192.20.135.21 255.255.255.0
 speed 100
 mls qos trust dscp
end 
Switch# show running-config interface fastethernet0/2 
Building configuration...

Current configuration : 236 bytes
!
interface FastEthernet0/2
 switchport mode access
 no ip address
 ip access-group SecWiz_Fa0_2_in_ip in
 mac access-group SecWiz_Fa0_2_in_mac in
 wrr-queue cos-map 1 3 4 5 6
 wrr-queue cos-map 4 1 2
 spanning-tree portfast trunk
end