Cisco Nexus 1000V Release Notes, Release 4.0(4)SV1(2)
Removal of the Capability Uplink Command
Cisco NX-OS Commands May Differ from Cisco IOS
Maximum Allowed VLANs and MAC Addresses per VLAN
DHCP Not Supported for the Management IP
Cisco Nexus 1000V Release Notes, Release 4.0(4)SV1(2)
Updated: May 9, 2013OL-20454-01-G0This document describes the features, limitations, and caveats for the Cisco Nexus 1000V Release 4.0(4)SV1(2) software. Use this document in combination with documents listed in the "Related Documentation" section.
Table 1 shows the online change history for this document.
Contents
This document includes the following information about the Cisco Nexus 1000V Release 4.0(4)SV1(2) software.
Introduction
The Cisco Nexus 1000V provides a distributed, layer 2 virtual switch that extends across many virtualized hosts. The Cisco Nexus 1000V manages a Datacenter defined by the vCenter Server. Each server in the Datacenter is represented as a line card in Cisco Nexus 1000V and can be managed as if it were a line card in a physical Cisco switch.
Cisco Nexus 1000V consists of the following two components:
•Virtual Supervisor Module (VSM), which contains the Cisco CLI, configuration, and high-level features
•Virtual Ethernet Module (VEM), which acts as a line card and runs in each virtualized server to handle packet forwarding and other localized functions.
Software Compatibility
The servers running the Cisco Nexus 1000V VSM and VEM must be in the VMware Hardware Compatibility list. This is a requirement for running the ESX 4.0 software.
For additional compatibility information, see the Cisco Nexus 1000V Compatibility Information, Release 4.0(4)SV1(2)
New and Changed Information
This section provides the following information about this release:
Changed Software Features
The following software features are changed in this release:
•Removal of the Capability Uplink Command
Removal of the Capability Uplink Command
The capability uplink command is removed from the port profile configuration in this release. A port profile used as an uplink is now designated as type ethernet instead.
When you upgrade the software, existing uplink port profiles are automatically changed to Ethernet type port profiles.
Evaluation Licenses
The Cisco Nexus 1000V software includes an evaluation license for 16 CPU sockets that are valid for a period of 60 days. The evaluation period starts when you install or upgrade the software. These evaluation licenses are only used if you do not have permanent licenses installed. When you install permanent licenses, the evaluation licenses are no longer used.
If you have evaluation licenses installed when you upgrade your software, they are invalidated.
If the 60 day evaluation period ends before you install permanent licenses, all VEMs become unlicensed.
Note Service Disruption—When VEMs are unlicensed, the vEthernet interfaces on the VEMs are removed from service and the traffic flowing to them from virtual machines is dropped. This traffic flow is not resumed until you add a permanent license file with licenses for the VEMs.
For more information, see the Cisco Nexus 1000V License Configuration Guide, Release 4.0(4)SV1(2).
Interface Rate Statistics
The following commands are changed to display 5 minute input and output packet or bit rate statistics for Ethernet and vEthernet interfaces.
•show interface ethernet
•show interface vethernet
For more information, see the Cisco Nexus 1000V Command Reference, Release 4.0(4)SV1(2).
vPC-HM
Virtual port channel host mode (vPC-HM) is changed as follows:
•Member ports in a port channel can connect to more than two upstream switches.
•Ports can be grouped into 32 subgroups (0-31) for traffic separation.
•The following command is added to the CLI for creating subgroups:
–channel-group auto mode on [sub-group {cdp | manual}] [mac-pinning]
•Static pinning is added. For more information, see the "Static Pinning" section.
New Software Features
The following software features are new in this release:
GUI Configuration Set Up
A GUI is provided for initial configuration of the VSM after installing the software. The GUI streamlines your configuration of the following:
•Create the SVS connection between the VSM and vCenter, and the resulting connection to the DVS.
•Create the following VMware port groups:
–Control port profile
–Packet port profile
–Management port profile
•Create the following VLANs:
–Control VLAN
–Packet VLAN
–Management VLAN
•Enable SSH and configure an SSH connection.
•Create a Cisco Nexus 1000V plug-in and register it on the vCenter server.
•Power off and then restart the VSM.
Layer 3 Control
With Layer 3 control, a VSM can be Layer 3 accessible and control hosts that reside in a separate Layer 2 network. All hosts controlled by a VSM, however, must still reside in the same Layer 2 network. Since a VSM cannot control a host that is outside of the Layer 2 network it controls, the host on which it resides must be controlled by another VSM.
For more information about Layer 3 control, see the following documents:
•Cisco Nexus 1000V System Management Configuration Guide, Release 4.0(4)SV1(2)
•Cisco Nexus 1000V Port Profile Configuration Guide, Release 4.0(4)SV1(2)
Virtual Service Domain
Virtual service domains (VSDs) allow you to classify and separate traffic for network services.
Interfaces within a VSD are shielded by a service VM (SVM) that provides a specialized service like a firewall, deep packet inspection (application aware networking), or monitoring.
Each Service VM has three virtual interfaces:
There is no source MAC learning on these interfaces.
For more information about virtual service domains, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
iSCSI Multipath
The iSCSI multipath feature sets up multiple routes between a server and its storage devices for maintaining a constant connection and balancing the traffic load. The multipathing software handles all input and output requests and passes them through on the best possible path.
For more information about the iSCSI Multipath feature, see the Cisco Nexus 1000V System Management Configuration Guide, Release 4.0(4)SV1(2).
XML API
The Xtensible markup language (XML) application programming interface (API) lets you quickly develop client applications to manage and monitor the Cisco Nexus 1000V.
Client applications encode requests in XML API tags sent to the device over secure SSH connections.
For more information about the XML API, see the Cisco Nexus 1000V XML API User Guide, Release 4.0(4)SV1(2)
DHCP Snooping
DHCP snooping acts like a firewall between untrusted hosts and trusted DHCP servers and functions as follows:
•Validates DHCP messages received from untrusted sources and filters out invalid response messages from DHCP servers.
•Builds and maintains a database of information about untrusted hosts with leased IP addresses.
•Uses this database to validate subsequent requests from untrusted hosts.
Dynamic ARP inspection (DAI) and IP Source Guard also use information stored in the DHCP snooping database. For more information about DHCP snooping, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
Dynamic ARP Inspection
Dynamic ARP Inspection (DAI) validates ARP requests and responses and functions as follows:
•Intercepts all ARP requests and responses on untrusted ports.
•Verifies that a packet has a valid IP-to-MAC address binding before updating the ARP cache or forwarding the packet.
•Drops invalid ARP packets.
DAI determines the validity of an ARP packet using the DHCP snooping database.
For more information about DAI, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
IP Source Guard
IP Source Guard filters traffic on interfaces and only permits traffic whose IP and MAC address matches that in the DHCP snooping database or static IP source entries that you configure.
MAC Pinning
If one or more upstream switches do not support port channels, you can use MAC pinning to assign each Ethernet port member to a particular port channel subgroup. There are a maximum of 32 subgroups, so a maximum of 32 Ethernet port members can be assigned.
For more information, see the Cisco Nexus 1000V Port Profile Configuration Guide, Release 4.0(4)SV1(2).
Static Pinning
You can use vPC-HM to configure a port channel subgroup so that traffic is forwarded only through its member ports by assigning (or pinning) one of the following to the subgroup:
•vEthernet interface
•Control VLAN
•Packet VLAN
For more information, see the following documents:
Cisco Nexus 1000V Port Profile Configuration Guide, Release 4.0(4)SV1(2).
Cisco Nexus 1000V Interface Configuration Guide, Release 4.0(4)SV1(2).
IPv6 Support
Support for IPv6 is added for the following:
•mgmt0 interface
•SNMP
•Syslog
For more information, see the following document:
Cisco Nexus 1000V System Management Configuration Guide, Release 4.0(4)SV1(2)
Limitations and Restrictions
•Cisco NX-OS Commands May Differ from Cisco IOS
•DHCP Not Supported for the Management IP
•LACP
Configuration Limits
Use the following configuration limits with Cisco Nexus 1000V:
Component Supported Limit Maximum Modules66
Virtual Ethernet (VEM)
64
Virtual Supervisor (VSM)
2
Hosts
64
Active VLANs across all VEMs
512
MACs over VLAN within a VEM
1024 (1K)
vEthernet interfaces per port profile
1024 (1K)
PVLAN
512
Distributed Virtual Switches (DVS) per vCenter
12
Per DVS Per HostVirtual Service Domains (VSD)
64
6
VSD Interfaces
2048
214
vEthernet interfaces
2K
216
Port Profiles
256
—
System Port Profiles
—
16
Port Channel
256
8
Physical Trunks
512
—
Physical NICs
—
32
vEthernet Trunks
256
8
ACL
128
161
ACEs per ACL
128
161
ACL Interfaces
2048
256
NetFlow Policies
32
8
NetFlow Interfaces
256
32
SPAN/ERSPAN Sessions
64
4
QoS Policy-Map
128
16
QoS Class-Map
1024
128
QoS Interfaces
2048
256
Port Security
1600
216
MultiCast Groups
512
64
1 This number can be exceeded if VEM has available memory.
Vmotion of VSM
Vmotion of VSM has the following limitations and restrictions:
•VMotion of a VSM is supported for both the active and standby VSM VMs. For high availability, it is recommended that the active VSM and standby VSM reside on separate hosts. To achieve this, and prevent a host failure resulting in the loss of both the active and standby VSM, it is recommended that distributed resource scheduling (DRS) be disabled for both the active and standby VSMs.
If you do not disable DRS, then you must use the VMware anti-affinity rules to ensure that the two virtual machines are never on the same host, and that a host failure cannot result in the loss of both the active and standby VSM.
•VMware VMotion does not complete when using an open virtual appliance (OVA) VSM installation, if the ISO is still mounted. To complete the VMotion, either click Edit Settings on the VM to disconnect the mounted ISO, or power off the VM. There is no functional impact resulting from this limitation.
VMware Lab Manager
VMware Lab Manager does not support using the Cisco Nexus 1000V.
Virtual Service Domain
Virtual service domain (VSD) has the following limitations and restrictions:
•VMotion is not supported for the service virtual machine (SVM) and should be disabled.
•To prevent loops in the network, the following should be configured before assigning a service virtual machine (SVM) to a port profile on vCenter:
–Inside port
–Outside port
–VSD
•To prevent it from flooding the network with packets, make sure to configure the inside or outside VSD port profile with a service port.
•To prevent loops in the network, when making any changes to the service virtual machine (SVM) port profile, do the following:
–First shut down the SVM.
–Make the changes to the SVM port profile
–Verify that the changes to the SVM port profile were applied.
–Restart the SVM.
•The control and packet VLANs must be removed from the allowed VLAN lists for an inside or outside VSD port profile, such as that used for Vshield.
For more information about VSD, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
Upgrade
Upgrading the software has the following limitations and restrictions:
•After the VSM feature support level is upgraded to support features in the new release, it cannot be downgraded again to a previous release.
•Connectivity to the VSM can be lost during a VEM upgrade when the VSM VM interfaces connect to its own DVS.
•Connectivity between the active and standby VSM can be lost during a VEM upgrade when the VEM being upgraded provides interface connectivity to one of the VSMs in the pair. In this case, both VSMs become active and lose connectivity. Use the following workaround:
–Power off the VSM connected to the VEM.
–Manually upgrade the VEM that provides interface connectivity to one VSM in the pair.
•If you use a proxy server to connect VUM to the Internet, you may need to disable the proxy before starting a VUM upgrade of your VEMs. Because in VMware versions before VUM Update 1, the proxy prevents VUM from communicating locally with the VSM, automatic VEM upgrades may fail if the proxy is not disabled first.
For more information about upgrades, see the Cisco Nexus 1000V Software Upgrade Guide, Release 4.0(4)SV1(2).
Access Lists
ACLs have the following limitations and restrictions:
Limitations:
•IPV6 ACL rules are not supported.
•VLAN-based ACLs (VACLs) are not supported.
•ACLs are not supported on port channels.
Restrictions:
•IP ACL rules do not support the following:
–fragments option
–addressgroup option
–portgroup option
–interface ranges
•Control VLAN traffic between the VSM and VEM does not go through ACL processing.
Netflow
The Netflow configuration has the following support, limitation, and restrictions:
•L2 match fields are not supported.
•Netflow Sampler is not supported.
•Netflow Exporter format V9 is supported
•Netflow Exporter format V5 is not supported.
•Multicast traffic type is not supported. Cache entries are created for multicast packets but packet/byte count does not reflect replicated packets.
•NetFlow is not supported on port channels.
The Netflow cache table has the following limitation:
•Immediate and Permanent cache types are not supported.
Note The cache size configured using the CLI defines the number of entries and not the size in bytes. The configured entries are allocated for each processor in the ESX host and the total memory allocated depends on the number of processors.
Port Security
Port Security has the following support, limitations, and restrictions:
•The Port Security feature is enabled globally by default.
The CLI command feature/no feature port-security is not supported.•In response to a security violation, you can shut down the port
•Port Security Violation Actions that are supported on a Secure port are Shutdown and Protect. The Restrict Violation Action is not supported.
•Port Security is not supported on the PVLAN promiscuous ports.
Port Profile
Port profiles have the following restrictions or limitations:
•If you attempt to remove a port profile that is in use, that is, one that has already been auto-assigned to an interface, the Cisco Nexus 1000V generates an error message and does not allow the removal.
•When you remove a port profile that is mapped to a VMware port group, the associated port group and settings within the vCenter Server are also removed.
•Policy names are not checked against the policy database when ACL/Netflow policies are applied through port profile. It is possible to apply a non-existent policy.
Telnet Enabled by Default
The Telnet server is enabled by default.
For more information about Telnet, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
SSH Support
Only SSH version 2 (SSHv2) is supported.
For more information, see the Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2).
Cisco NX-OS Commands May Differ from Cisco IOS
Be aware that the Cisco NX-OS CLI commands and modes may differ from those used in Cisco IOS.
For information about CLI commands, see the Cisco Nexus 1000V Command Reference, Release 4.0(4)SV1(2).
For information about the CLI command modes, see the Cisco Nexus 1000V Getting Started Guide, Release 4.0(4)SV1(2)
Layer 2 Switching
This section lists the Layer 2 switching limitations and restrictions and includes the following topics:
•Maximum Allowed VLANs and MAC Addresses per VLAN.
For detailed information about Layer 2 switching, see the Cisco Nexus 1000V Layer 2 Switching Configuration Guide, Release 4.0(4)SV1(2).
No Spanning Tree Protocol
Its forwarding logic is designed to prevent network loops so the Cisco Nexus 1000V does not need to participate in Spanning Tree Protocol. Packets received from the network on any link connecting the host to the network are not forwarded back to the network by the Cisco Nexus 1000V.
MAC Address Table
The following are limitations and restrictions for the MAC address table:
•The forwarding table for each VLAN in a VEM can store up to 1024 MAC addresses.
For detailed information about the Cisco Nexus 1000V MAC address table, see the Cisco Nexus 1000V Layer 2 Switching Configuration Guide, Release 4.0(4)SV1(2).
Maximum Allowed VLANs and MAC Addresses per VLAN
The following are the allowable number of VLANs and MAC addresses per VLAN that can be configured:
For detailed information about Cisco Nexus 1000V VLAN configuration, see the Cisco Nexus 1000V Layer 2 Switching Configuration Guide, Release 4.0(4)SV1(2).
Cisco Discovery Protocol
Cisco Discovery Protocol (CDP) is enabled globally by default.
CDP runs on all Cisco-manufactured equipment over the data link layer and does the following:
•Advertises information to all attached Cisco devices.
•Discovers and views information about those Cisco devices.
–CDP can discover up to 256 neighbors per port if the port is connected to a hub with 256 connections.
If disabled globally, then CDP is also disabled for all interfaces.
For more information about Cisco Discovery Protocol, see the Cisco Nexus 1000V System Management Configuration Guide, Release 4.0(4)SV1(2).
DHCP Not Supported for the Management IP
DHCP is not supported for the management IP. The management IP must be configured statically.
LACP
Link Aggregation Control Protocol is an IEEE standard protocol that aggregates Ethernet links into an Etherchannel.
Cisco Nexus 1000V has the following restrictions for enabling LACP on ports carrying the Control and Packet VLANs:
Note These restrictions do not apply to other data ports using LACP.
•At least two ports must be configured as part of the LACP channel.
•The upstream switch ports must be configured in spanning-tree portfast mode. The LACP negotiation causes upstream switchports to bounce as per protocol before starting the port aggregation process.
Without spanning-tree portfast on upstream switch ports, it takes ~30 seconds to recover these ports on the upstream switch, and since they are carrying Control and Packet VLANs, VSM loses connectivity to the VEM.
The following commands are available to use on Cisco upstream switch ports in interface configuration mode:
spanning-tree portfast
spanning-tree portfast trunk
spanning-tree portfast edge trunk
Caveats
This section includes the following topics:
Open Caveats
The following is a list of open caveats in Cisco Nexus 1000V Release 4.0(4)SV1(2). The Bug ID links you into the Cisco Bug Toolkit.
Resolved Caveats
The following is a list of caveats that were resolved in Cisco Nexus 1000V Release 4.0(4)SV1(2). The Bug ID links you into the Cisco Bug Toolkit.
MIB Support
The Cisco Management Information Base (MIB) list includes Cisco proprietary MIBs and many other Internet Engineering Task Force (IETF) standard MIBs. These standard MIBs are defined in Requests for Comments (RFCs). To find specific MIB information, you must examine the Cisco proprietary MIB structure and related IETF-standard MIBs supported by the Cisco Nexus 1000V Series switch.
The MIB Support List is available at the following FTP site:
ftp://ftp.cisco.com/pub/mibs/supportlists/nexus1000v/Nexus1000VMIBSupportList.html
Related Documentation
Cisco Nexus 1000V includes the following documents available on Cisco.com:
General Information
Cisco Nexus 1000V Release Notes, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Compatibility Information, Release 4.0(4)SV1(2)
Install and Upgrade
Cisco Nexus 1000V Software Installation Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Software Upgrade Guide, Release 4.0(4)SV1(2)
Configuration Guides
Cisco Nexus 1000V License Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Getting Started Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Interface Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Layer 2 Switching Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Port Profile Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Quality of Service Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Security Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V System Management Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V High Availability and Redundancy Configuration Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V XML API User Guide, Release 4.0(4)SV1(2)
Programming Guide
Cisco Nexus 1000V XML API User Guide, Release 4.0(4)SV1(2)
Reference Guides
Cisco Nexus 1000V Command Reference, Release 4.0(4)SV1(2)
Cisco Nexus 1000V MIB Quick Reference
Troubleshooting and Alerts
Cisco Nexus 1000V Troubleshooting Guide, Release 4.0(4)SV1(2)
Cisco Nexus 1000V Password Recovery Guide
Cisco NX-OS System Messages Reference
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
Internet Protocol (IP) addresses and phone numbers that are used in the examples, command display output, and figures within this document are for illustration only. If an actual IP address or phone number appears in this document, it is coincidental.
© 2010 Cisco Systems, Inc. All rights reserved.