Inter-VSAN Routing Configuration Guide, Cisco DCNM for SAN, Release 5.x
Configuring Advanced Inter-VSAN Routing
Downloads: This chapterpdf (PDF - 227.0KB) The complete bookPDF (PDF - 1.54MB) | Feedback

Configuring Advanced Inter-VSAN Routing

Table Of Contents

Configuring Advanced Inter-VSAN Routing

Information About Advanced Inter-VSAN Routing

IVR Service Groups

Default Service Group

Service Group Activation

Autonomous Fabric IDs

FC ID Features and Benefits

Advanced IVR Zones and IVR Zone Sets

IVR CFS Region

Advanced Fabric Services on IVR Flows

Guidelines and Limitations

Service Group Guidelines

Autonomous Fabric ID Guidelines

IVR Without IVR NAT or IVR Auto Topology Guidelines

Domain ID Guidelines

Transit VSAN Guidelines

Border Switch Guidelines

Manual IVR Topology Configuration Guidelines

FC ID Guidelines

IVR Zone Configuration Guidelines

Advanced Fabric Services Guidelines and Limitations

Configuring Advanced Inter-VSAN Routing

Task Flow for Configuring Advanced Inter-VSAN Routing

Configuring IVR Service Groups

Configuring Default AFIDs

Configuring Individual AFIDs

Configuring IVR Without NAT

Manually Configuring an IVR Topology

Activating a Manually Configured IVR Topology

Clearing a Manually Configured IVR Topology Database

Migrating from IVR Auto Topology Mode to IVR Manual Topology Mode

Configuring Persistent FC IDs for IVR

Configuring LUNs in IVR Zoning

Configuring QoS for IVR Zones

Renaming IVR Zones and IVR Zone Sets

Configuring IVR CFS Region ID

Configuring IVR Using Read-Only Zoning


Configuring Advanced Inter-VSAN Routing


This chapter provides advanced configuration information and instructions. Before setting up advanced IVR configurations, see Chapter 1, "Configuring Basic Inter-VSAN Routing," which includes basic configuration instructions and descriptions of IVR features, limits, and terminology.

This chapter includes the following sections:

Information About Advanced Inter-VSAN Routing

Guidelines and Limitations

Configuring Advanced Inter-VSAN Routing

Information About Advanced Inter-VSAN Routing

This section includes the following topics:

IVR Service Groups

Default Service Group

Service Group Activation

Autonomous Fabric IDs

FC ID Features and Benefits

Advanced IVR Zones and IVR Zone Sets

Advanced Fabric Services on IVR Flows

IVR Service Groups

In a complex network topology, you might only have a few IVR-enabled VSANs. To reduce the amount of traffic to non-IVR-enabled VSANs, you can configure service groups that restrict the traffic to the IVR-enabled VSANs. A maximum of 16 IVR service groups are allowed in a network. When a new IVR-enabled switch is added to the network, you must update the service groups to include the new VSANs.

Default Service Group

All AFID and VSAN combinations that are part of an IVR VSAN topology but are not part of any user-defined service group are members of the default service group. The identifier of the default service group is 0.

By default, IVR communication is permitted between members of the default service group. You can change the default policy to deny. To change the default policy, see "Configuring IVR Service Groups" on page 2-9. The default policy is not part of ASCII configuration.

Service Group Activation

A configured service group must be activated. Like zone set activation or VSAN topology activation, the activation of a configured service group replaces the currently active service group, if any, with the configured one. There is only one configured service group database and one active service group database. Each of these databases can have up to 16 service groups.

Autonomous Fabric IDs

The autonomous fabric ID (AFID) distinguishes segmented VSANS (for example, two VSANs that are logically and physically separate but have the same VSAN number). Cisco Fabric Manager Release 4.2(1) supports AFIDs 1 through 64. AFIDs are used in conjunction with IVR auto topology mode to allow segmented VSANs in the IVR VSAN topology database.

FC ID Features and Benefits

FC ID persistence improves IVR management by providing the following features:

Allows you to control and assign a specific virtual domain to use in a native VSAN.

Allows you to control and assign a specific virtual FC ID for a device.

The benefits of persistent FC IDs for IVR are as follows:

Host devices always see the same FC ID for targets.

FC IDs help you plan your SAN layout better by assigning virtual domains for IVR to use.

FC IDs can make SAN monitoring and management easier. When you see the same domain or FC ID consistently assigned, you can readily determine the native VSAN or device to which it refers.

Advanced IVR Zones and IVR Zone Sets

This section describes advanced configuration information for IVR zones and IVR zone sets. For basic information on configuring IVR zones and zone sets, see "Configuring IVR Zones and IVR Zone Sets" on page 1-18.

As part of the IVR configuration, you need to configure one or more IVR zone to enable cross-VSAN communication. To achieve this, you must specify each IVR zone as a set of (pWWN, VSAN) entries. Different IVR zone sets can contain the same IVR zone, because IVR zones can be members of one or more IVR zone sets.


Note The same IVR zone set must be activated on all of the IVR-enabled switches.



Caution Prior to Cisco SAN-OS Release 3.0(3) you can only configure a total of 10,000 zone members on all switches in a network. As of Cisco SAN-OS Release 3.0(3) you can only configure a total of 20,000 zone members on all switches in a network. A zone member is counted twice if it exists in two zones. See "Database Merge Guidelines" on page 1-11.

IVR CFS Region

IVR is used for devices from different VSANs to communicate with each other. As the fabric size increases, there is a need to create IVR islands. The IVR data communication is limited only within the islands. By creating various IVR CFS regions, the data communication can be limited to the regions.

Currently, DCNM-SAN only supports a single IVR CFS region.

Beginning with Release 5.2, DCNM-SAN supports multiple IVR regions and has the following features:

Supports multiple IVR enforced zone sets and IVR master switch (per region).

Shows active and local topology for all switches in DCNM-SAN tables. You need to select a master switch to change the topology for each region.

If no CFS IVR region is configured, the switch belongs to a default region.

DCNM-SAN discovers multiple enforced IVR zones by region, region ID, and IVR CFS state of each switch.

The client or server events are modified to account for changes in the IVR CFS state, region ID, and enforced IVR zones (for each region).

The log window in DCNM-SAN client will reflect all regions information for IVR.

Currently, DCNM-SAN client supports zoning in CFS regions.

Advanced Fabric Services on IVR Flows

Advanced fabric services (such as SME and IOA) use a fabric-wide FC-Redirect infrastructure to redirect the traffic flows. These services can now be enabled on IVR flows using an internal feature, Abstract ACL Manager (AAM).

Guidelines and Limitations

This section includes the following topics:

Service Group Guidelines

Autonomous Fabric ID Guidelines

IVR Without IVR NAT or IVR Auto Topology Guidelines

Manual IVR Topology Configuration Guidelines

FC ID Guidelines

IVR Zone Configuration Guidelines

Advanced Fabric Services Guidelines and Limitations

Service Group Guidelines

When configuring IVR service groups, consider these guidelines:

If you use service groups with IVR auto topology mode, you should enable IVR and configure your service groups first, then distribute them with CFS before setting the IVR auto topology mode.

The CFS distribution is restricted within the service group only when the IVR VSAN topology is in IVR auto topology mode. See "IVR VSAN Topology" on page 1-6.

You can configure as many as 16 service groups in a network.

When a new IVR-enabled switch is added to the network, you must update the service group to include the new VSANs.

The same VSAN and AFID combination cannot be a member of more than one service group, otherwise, a CFS merge will fail.

The total number of AFID and VSAN combinations in all the service groups combined cannot exceed 128. The maximum number of AFID and VSAN combinations in a single service group is 128.

The IVR service group configuration is distributed in all IVR-enabled switches. IVR data traffic between two end devices belonging to a service group stays within that service group. For example, two members (for example, pWWN 1 and pWWN 2) cannot communicate if they belong to the same IVR zone and they belong to different service groups.

During a CFS merge, service groups with the same name would be merged, as long as there are no conflicts with other service groups.

If the total number of service groups exceeds 16 during a CFS merge, the CFS merge fails.

CFS distributes service group configuration information to all reachable SANs. If you do not enable CFS distribution, you must ensure that the service group configuration is the same on all IVR-enabled switches in all VSANs.

IVR end devices belonging to an IVR service group are not exported to any AFID or VSAN outside of its service group.

When at least one service group is defined and an IVR zone member does not belong to the service group, that IVR zone member is not able to communicate with any other device.

The default service group ID is zero (0).

Autonomous Fabric ID Guidelines

You can configure AFIDs individually for VSANs, or you can set the default AFIDs for all VSANs on a switch. If you configure an individual AFID for a subset of the VSANs on a switch that has a default AFID, that subset uses the configured AFID while all other VSANs on that switch use the default AFID.

You can only use an AFID configuration when the VSAN topology is in IVR auto topology mode. In IVR manual topology mode, the AFIDs are specified in the VSAN topology configuration itself and a separate AFID configuration is not needed.


Note Two VSANs with the same VSAN number but different AFIDs are counted as two VSANs out of the total 128 VSANs allowed in the fabric.


When devices attached to multiple switches belong to one VSAN, they cannot communicate with each other by configuring the regular zone set because the AFIDs are different. You can consider that the different AFIDs are different fabrics; therefore, the three switches represent three separate fabrics.

IVR Without IVR NAT or IVR Auto Topology Guidelines

Before configuring an IVR SAN fabric without IVR in NAT mode or IVR auto topology mode, consider the following general guidelines:

Acquire a mandatory Enterprise License Package or SAN-EXTENSION license package and one active IPS card for this feature.

If you change an FSPF link cost, ensure that the FSPF path distance (the sum of the link costs on the path) of any IVR path is less than 30,000.

IVR-enabled VSANs can be configured when an interop mode is enabled or disabled.

This section also includes the following topics:

Domain ID Guidelines

Transit VSAN Guidelines

Border Switch Guidelines

Domain ID Guidelines

Before configuring domain IDs, consider the following guidelines:

Configure unique domain IDs across all VSANs and switches participating in IVR operations if you are not using IVR NAT. The following switches participate in IVR operations:

All edge switches in the edge VSANs (source and destination)

All switches in transit VSANs

Minimize the number of switches that require a domain ID assignment. This ensures minimum traffic disruption.

Minimize the coordination between interconnected VSANs when configuring the SAN for the first time as well as when you add each new switch.

You can configure domain IDs using one of two options:

Configure the allowed-domains list so that the domains in different VSANs are non-overlapping on all participating switches and VSANs.

Configure static, non-overlapping domains for each participating switch and VSAN.


Note In a configuration involving IVR without NAT, if one VSAN in the IVR topology is configured with static domain IDs, then the other VSANs (edge or transit) in the topology must be configured with static domain IDs.


Transit VSAN Guidelines

Before configuring transit VSANS, consider the following guidelines:

Besides defining the IVR zone membership, you can choose to specify a set of transit VSANs to provide connectivity between two edge VSANs:

If two edge VSANs in an IVR zone overlap, then a transit VSAN is not required (though, not prohibited) to provide connectivity.

If two edge VSANs in an IVR zone do not overlap, you may need one or more transit VSANs to provide connectivity. Two edge VSANs in an IVR zone will not overlap if IVR is not enabled on a switch that is a member of both the source and destination edge VSANs.

Traffic between the edge VSANs only traverses through the shortest IVR path.

Transit VSAN information is common to all IVR zone sets. Sometimes, a transit VSAN can also act as an edge VSAN in another IVR zone.

Border Switch Guidelines

Before configuring border switches, consider the following guidelines:

Configure IVR only in the relevant border switches.

Border switches require Cisco MDS SAN-OS Release 1.3(1) or later.

A border switch must be a member of two or more VSANs.

A border switch that facilitates IVR communications must be IVR enabled.

IVR can also be enabled on additional border switches to provide redundant paths between active IVR zone members.

The VSAN topology configuration must be updated before a border switch is added or removed.

Manual IVR Topology Configuration Guidelines

You must create the IVR topology on every IVR-enabled switch in the fabric if you have not enabled IVR auto topology mode. Consider the following guidelines when using IVR manual topology mode:

You can configure a maximum of 128 IVR-enabled switches and 128 distinct VSANs in an IVR topology (see "Database Merge Guidelines" on page 1-11).

You will need to specify the IVR topology using the following information:

The switch WWNs of the IVR-enabled switches.

A minimum of two VSANs to which the IVR-enabled switch belongs.

The AFID, which distinguishes two VSANs that are logically and physically separate, but have the same VSAN number. You can specify up to 64 AFIDs. See Figure 2-1.

Figure 2-1 Example IVR Topology with Non-Unique VSAN IDs Using AFIDs

If two VSANs in an IVR topology have the same VSAN ID and different AFIDs, they count as two VSANs for the 128-VSAN limit for IVR.

The use of a single AFID does not allow for segmented VSANs in an inter-VSAN routing topology.

FC ID Guidelines

Before configuring persistent FC IDs, consider the following:

You can configure two types of database entries for persistent IVR FC IDs:

Virtual domain entries—Contain the virtual domain that should be used to represent a native VSAN in a specific VSAN (current VSAN). Virtual domain entries contain the following information:

Native AFID

Native VSAN

Current AFID

Current VSAN

Virtual domain to be used for the native AFID and VSAN in current AFID and VSAN

Virtual FC ID entries—Contain the virtual FC ID that should be used to represent a device in a specific VSAN (current VSAN). Virtual FC ID entries contain the following information:

Port WWN

Current AFID

Current VSAN

Virtual FC ID to be used to represent a device for the given pWWN in the current AFID and VSAN

If you use persistent FC IDs for IVR, we recommend that you use them for all the devices in the IVR zone set. We do not recommend using persistent FC IDs for some of the IVR devices while using automatic allocation for other devices.

IVR NAT must be enabled to use IVR persistent FC IDs.

In an IVR NAT configuration, if one VSAN in the IVR topology is configured with static domain IDs, then the IVR domains that can be exported to that VSAN must also be assigned static domains.

IVR Zone Configuration Guidelines

When interop mode is enabled, consider the following IVR configuration guidelines:

When a member's native VSAN is in interop mode (for example, when the interop mode is 2, 3, or 4), then ReadOnly, the QoS attribute, and LUN zoning are not permitted.

When a member's VSAN is already in interop mode and an attempt is made to configure ReadOnly, the QoS attribute, or LUN zoning, a warning message is displayed to indicate that the configuration is not permitted.

When you configure ReadOnly, the QoS attribute, or LUN zoning first, and then change the member's VSAN interop mode, a warning message is displayed to indicate the configuration is not permitted. You are then prompted to change the configuration.

Advanced Fabric Services Guidelines and Limitations

The following guidelines and limitations must be considered before enabling AAM for IVR:

CFS distribution must be enabled for IVR.

AAM is supported only in IVR-NAT mode.

The switches where the fabric services (such as SME and IOA) are enabled must be running the AAM supported NX-OS Release 5.0(1) or later.

FC-Redirect can be running in version 1 or version 2 mode.

AAM support for IVR must be enabled before enabling IVR support for FCR.

Generation 1 modules are not supported when IVR support is enabled for FCR. Specifically, ISLs should not be configured on Generation 1 modules, and the devices that support IVR for FCR should not be connected to Generation 1 modules.

LUN zoning is not supported when AAM is enabled for IVR.

IVR merge is supported only when both the fabrics have AAM enabled or both the fabrics have AAM disabled. The IVR merge will fail if one of the fabric has AAM enabled and the other fabric has AAM disabled.

You must delete all the advanced fabric service (SME and IOA) configurations for IVR devices and then disable IVR support for FCR before disabling AAM support for IVR.

Before downgrading to an earlier release to MDS NX-OS Release 5.0(1), you must delete all of the advanced fabric service (SME and IOA) configurations for IVR devices, disable IVR support for FCR, and then disable AAM support for IVR.

Configuring Advanced Inter-VSAN Routing

This section includes the following topics:

Task Flow for Configuring Advanced Inter-VSAN Routing

Configuring IVR Service Groups

Configuring Default AFIDs

Configuring Individual AFIDs

Configuring IVR Without NAT

Manually Configuring an IVR Topology

Activating a Manually Configured IVR Topology

Clearing a Manually Configured IVR Topology Database

Migrating from IVR Auto Topology Mode to IVR Manual Topology Mode

Configuring Persistent FC IDs for IVR

Configuring LUNs in IVR Zoning

Configuring QoS for IVR Zones

Renaming IVR Zones and IVR Zone Sets

Configuring IVR Using Read-Only Zoning

Task Flow for Configuring Advanced Inter-VSAN Routing

To configure an advanced IVR topology in a SAN fabric, follow these steps:

 
Configuration Task
Resource

Step 1 

Determine whether or not to use IVR Network Address Translation (NAT).

See "IVR Network Address Translation" on page 1-6 and "IVR NAT Requirements and Guidelines" on page 1-9.

Step 2 

If you do not plan to use IVR NAT, verify that unique domain IDs are configured in all switches and VSANs participating in IVR.

See "Domain ID Guidelines" on page 2-5.

Step 3 

Enable IVR in the border switches.

See "Configuring IVR and IVR Zones Using the IVR Zone Wizard" on page 1-15

Step 4 

Configure the service group as required.

See "IVR Service Groups" on page 2-1.

Step 5 

Configure the IVR distribution as required.

 

Step 6 

Configure the IVR topology, either manually or automatically.

See"Manually Configuring an IVR Topology" on page 2-11 and "Configuring Basic Inter-VSAN Routing" on page 1-14.

Step 7 

Create and activate IVR zone sets in all of the IVR-enabled border switches, either manually or using fabric distribution.

See "Advanced IVR Zones and IVR Zone Sets" on page 2-2.

Configuring IVR Service Groups

Detailed Steps

To configure an IVR service group, follow these steps:


Step 1 Expand All VSANs, and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Service Group tab to display the existing service groups.

Step 3 Click the Create Row icon to make a new service group.

You see the service group dialog box.

Step 4 Check the switch check box for each switch involved in IVR.

Step 5 Complete the Name field for the service group and fill in the Fabric ID field for this entry.

Step 6 Enter a comma-separated list of VSAN IDs in the VSAN List text box.

Step 7 Click Create to create this entry or click Cancel to discard all changes.

Step 8 Repeat Step 1 through Step 7 for all switches and AFIDs associated with your IVR topology.


Configuring Default AFIDs

Detailed Steps

To configure default AFIDs, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Default Fabric ID tab to display the existing default AFIDs.

Step 3 Click the Create Row icon to create a default AFID.

Step 4 Check the check boxes next to each switch involved in IVR that you want to use this default AFID.

Step 5 Provide a name for each switch WWN and set the default fabric ID.

Step 6 Click Create to create this entry.

Step 7 Repeat Step 1 through Step 6 for all default AFIDs that you want to configure in your IVR topology.


Configuring Individual AFIDs

Detailed Steps

To configure individual AFIDs, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Fabric ID tab to display the existing AFIDs.

Step 3 Click the Create Row icon to create an AFID.

Step 4 Check the check box next to each switch involved in IVR that you want to use this default AFID.

Step 5 Provide a name for each switch WWN and set the fabric ID.

Step 6 Enter a comma-separated list of VSAN IDs in the VSAN List text box.

Step 7 Click Create to create this entry.

Step 8 Repeat Step 1 through Step 6 for all switches and AFIDs you want to configure in your IVR topology.


Configuring IVR Without NAT

Detailed Steps

To enable IVR without NAT, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Action tab.

Step 3 Uncheck the Enable IVR NAT check box.

Step 4 Click the Apply Changes icon to distribute this change to all switches in the fabric.


Manually Configuring an IVR Topology

Restrictions

Transit VSANs are determined based on your configuration. The IVR feature does not have an explicit transit-VSAN configuration.

Most tabs in the Information pane for features using CFS are dimmed until you click the CFS tab. The CFS tab shows which switches have CFS enabled and shows the master switch for this feature. Once the CFS tab is clicked, the other tabs in the Information pane are activated.

You can configure IVR using the IVR tables in the Information pane in DCNM-SAN. Use these tables only if you are familiar with all IVR concepts. We recommend you configure IVR using the IVR Wizard. See "Configuring IVR and IVR Zones Using the IVR Zone Wizard" on page 1-15.

Detailed Steps

To manually configure an IVR topology, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Local Topology tab to display the existing IVR topology.

Step 3 Click the Create Row icon to create rows in the IVR topology.

Step 4 Select the switch, switch WWN, and a comma-separated list of VSAN IDs for this topology.

Step 5 Click Create to create this new row.

Step 6 Click the Apply Changes icon to create the IVR topology.


Repeat this configuration on all IVR-enabled switches or distribute the IVR configuration using CFS.

Activating a Manually Configured IVR Topology

After manually configuring the IVR topology, you must activate it.

Restrictions

Active IVR topologies cannot be deactivated. You can only switch to IVR auto topology mode.

Detailed Steps

To activate a manually configured IVR topology, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Action tab to display the existing IVR topology.

Step 3 Check the Activate Local Topology check box.

Step 4 Click the Apply Changes icon to activate the IVR topology.


Clearing a Manually Configured IVR Topology Database

Detailed Steps

To clear a manually created IVR topology database, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

Step 2 Click the Control tab if it is not already displayed.

Step 3 Highlight the rows you want to delete from the IVR topology.

Step 4 Click the Delete Row icon to delete these rows from the IVR topology.

Step 5 Click the Apply Changes icon to delete the IVR topology.


Migrating from IVR Auto Topology Mode to IVR Manual Topology Mode

Prerequisites

If you want to migrate from IVR auto topology mode to IVR manual topology mode, copy the active IVR VSAN topology database to the user-configured IVR VSAN topology database before switching modes.

Detailed Steps

To migrate from IVR auto topology mode to IVR manual topology mode, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Action tab.

Step 3 Highlight the switch on which you want to disable IVR auto topology mode.

Step 4 Uncheck the Auto Discover Topology check box.

Step 5 Click the Apply Changes icon.


Configuring Persistent FC IDs for IVR

Detailed Steps

To configure persistent FC IDs for IVR, follow these steps:


Step 1 Expand All VSANs and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the FCID tab.

Step 3 Click the Create Row icon to create an FC ID.

Step 4 Select the switch for which you are configuring the virtual FC ID to be used to represent a device in a specific VSAN (current VSAN).

Step 5 Enter the current fabric in the Current Fabric ID field for the fcdomain database.

Step 6 Enter the current VSAN in the Current VSAN ID field for the fcdomain database.

Step 7 Enter the pWWN.

Step 8 Click the drop-down menu to select the FC ID to map to the pWWN you selected.

Step 9 Click Create to create this new row.


Configuring LUNs in IVR Zoning

LUN zoning can be used between members of active IVR zones.You can configure the service by creating and activating LUN zones between the desired IVR zone members in all relevant edge VSANs using the zoning interface or you can use LUN zoning directly supported by IVR. For more details on the advantages of LUN zoning, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide or the Fabric Configuration Guide, Cisco DCNM for SAN.


Note You can configure LUN zoning in an IVR zone set setup.


Configuring QoS for IVR Zones


Note The default QoS attribute setting is low.


Detailed Steps

To configure QoS for an IVR zone, follow these steps:


Step 1 Choose Zone > Edit Local Full Zone Database.

You see the Edit IVR Local Full Zone Database dialog box for the VSAN you selected.

Step 2 Select Zones or a zone set.

Step 3 Check the QoS check box and set the QoS priority.

Step 4 Click Activate to make the changes.


Renaming IVR Zones and IVR Zone Sets

Detailed Steps

To rename an IVR zone or IVR zone set, follow these steps:


Step 1 Choose Zone > Edit Local Full Zone Database.

You see the Edit IVR Local Full Zone Database dialog box for the VSAN you selected.

Step 2 Click a zone or zone set in the left pane.

Step 3 Choose Edit > Rename.

An edit box appears around the zone or zone set name.

Step 4 Enter a new name.

Step 5 Click Activate or Commit Changes.


Configuring IVR CFS Region ID

To configure IVR CFS region, follow these steps:


Step 1 Expand All VSANs, and then select IVR in the Logical Domains pane.

You see the IVR configuration in the Information pane.

Step 2 Click the Control tab to enable the feature on the switch.

You see only the switches in the selected region. All switches without the IVR region configuration are a part of a default region.

Step 3 Expand Switches and select CFS in the Physical Attributes pane.

If the feature is enabled correctly, the switch appears in the CFS tab.

Step 4 Select All Regions and click Create Row.

Step 5 Enter the Region ID for the switch.

Step 6 Click Activate or Commit Changes.


Configuring IVR Using Read-Only Zoning

Read-only zoning (with or without LUNs) can be used between members of active IVR zones. To configure this service, you must create and activate read-only zones between the desired IVR zone members in all relevant edge VSANs using the zoning interface.