Guest

Cisco MDS 9000 NX-OS and SAN-OS Software

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)

  • Viewing Options

  • PDF (502.9 KB)
  • Feedback
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)

Table Of Contents

Cisco MDS 9000 Family Release Notes
for Cisco MDS NX-OS Release 5.0(4c)

Contents

Introduction

Components Supported

MDS 9000 Chassis and Module Support

Migrating from Supervisor-1 Modules to Supervisor-2 Modules

Software Download Process

Determining the Software Version

Determining Software Version Compatibility

Downloading Software

Selecting the Correct Software Image for an MDS 9100 Series Switch

Selecting the Correct Software Image for an MDS 9200 Series Switch

Selecting the Correct Software Image for an MDS 9500 Series Switch

Upgrading Your Cisco MDS NX-OS Software Image

General Upgrading Guidelines

FICON Supported Releases and Upgrade Paths

Upgrading Effect on VSAN 4079

Upgrading with IVR Enabled

Upgrading a Cisco MDS 9124 or Cisco MDS 9134 Switch

Performing a Disruptive Upgrade on an MDS 9000 Family Switch

Resetting SNMP Notifications

Converting Automatically Created PortChannels Before an Upgrade

Downgrading Your Cisco MDS SAN-OS Software Image

General Downgrading Guidelines

NX-OS Release 5.0(x) Software Downgrade and Upgrade Matrix for Cisco MDS 9509 and 9506 Switches

FICON Downgrade Paths

New Features in Cisco MDS NX-OS Release 5.0(4c)

Licensed Cisco NX-OS Software Packages

Enterprise Package

SAN Extension over IP Package

Mainframe Package

Storage Media Encryption Package

Data Mobility Manager Package

Storage Services Enabler Package

On-Demand Port Activation License

I/O Accelerator Package

XRC Acceleration License

Limitations and Restrictions

Support for Generation One Modules

IPv6

User Roles

Red Hat Enterprise Linux

Generation 1 Module Limitation

Schedule Job Configurations

Maximum Number of Zones Supported in Interop Mode 4

InterVSAN Routing

Java Web Start

VRRP Availability

Using a RSA Version 1 Key for SSH Following an Upgrade

CFS Cannot Distribute All Call Home Information

Availability of F Port Trunking and F Port Channels

Reserved VSAN Range and Isolated VSAN Range Guidelines

Applying Zone Configurations to VSAN 1

Running Storage Applications on the MSM-18/4

RSPAN Traffic Not Supported on CTS Ports on 8-Gbps Switching Modules

I/O Accelerator Feature Limitations

Support for FCIP Compression Modes

Saving Copies of the Running Kickstart and System Images

Configuring Buffer Credits on a Generation 2 or Generation 3 Module

Features Not Supported on the Cisco MDS 9148 Switch

PPRC Not Supported with FCIP Write Acceleration

Configuring a Persistent FCID in an IVR Configuration with Brocade Switches

Caveats

Resolved Caveats

Open Caveats

Related Documentation

Release Notes

Regulatory Compliance and Safety Information

Compatibility Information

Hardware Installation

Software Installation and Upgrade

Cisco NX-OS

Command-Line Interface

Intelligent Storage Networking Services Configuration Guides

Troubleshooting and Reference

Obtaining Documentation and Submitting a Service Request


Cisco MDS 9000 Family Release Notes
for Cisco MDS NX-OS Release 5.0(4c)


Release Date: April 5, 2011

Part Number: OL-21012-05 F0

This document describes the caveats and limitations for switches in the Cisco MDS 9000 Family. Use this document in conjunction with documents listed in the "Related Documentation" section.


Note As of Cisco Fabric Manager Release 4.2(1a), Fabric Manager information will no longer appear in the Cisco MDS 9000 Family Release Notes for NX-OS releases. Cisco Fabric Manager Release Notes will include information that is exclusive to Fabric Manager as a management tool for Cisco MDS 9000 Family switches and Cisco Nexus 5000 Series switches. Refer to the following website for Release Notes for Cisco Fabric Manager:
http://www.cisco.com/en/US/products/ps10495/prod_release_notes_list.html


Release notes are sometimes updated with new information on restrictions and caveats. Refer to the following website for the most recent version of the Cisco MDS 9000 Family Release Notes: http://www.cisco.com/en/US/products/ps5989/prod_release_notes_list.html

Table 1 Online History Change 

Revision
Date
Description

A0

04/05/2011

Created release notes.

B0

04/08/2011

Added DDTS CSCto05539.

C0

04/29/2011

Added DDTS CSCtn68418 as an Open Caveat.

Added DDTS CSCto68011 as an Open Caveat.

D0

09/10/2011

Updated Table 11.

Added the limitation "Configuring a Persistent FCID in an IVR Configuration with Brocade Switches".

E0

03/11/2012

Updated Table 11 and Table 15.

F0

April 30, 2012

Added the "NX-OS Release 5.0(x) Software Downgrade and Upgrade Matrix for Cisco MDS 9509 and 9506 Switches" section.

Added open caveat CSCty32238.

Corrected Table 11.


Contents

This document includes the following:

Introduction

Components Supported

MDS 9000 Chassis and Module Support

Migrating from Supervisor-1 Modules to Supervisor-2 Modules

Software Download Process

Upgrading Your Cisco MDS NX-OS Software Image

Downgrading Your Cisco MDS SAN-OS Software Image

New Features in Cisco MDS NX-OS Release 5.0(4c)

Licensed Cisco NX-OS Software Packages

Limitations and Restrictions

Caveats

Related Documentation

Obtaining Documentation and Submitting a Service Request

Introduction

The Cisco MDS 9000 Family of Multilayer Directors and Fabric Switches provides industry-leading availability, scalability, security, and management, allowing you to deploy high performance storage-area networks with lowest total cost of ownership. Layering a rich set of intelligent features onto a high performance, protocol agnostic switch fabric, the Cisco MDS 9000 Family addresses the stringent requirements of large data center storage environments: uncompromising high availability, security, scalability, ease of management, and seamless integration of new technologies.

Cisco MDS 9000 NX-OS Software powers the award winning Cisco MDS 9000 Series Multilayer Switches. It is designed to create a strategic SAN platform with superior reliability, performance, scalability, and features. Formerly known as Cisco SAN-OS, Cisco MDS 9000 NX Software is fully interoperable with earlier Cisco SAN-OS versions and enhances hardware platform and module support.

Components Supported

Table 2 lists the NX-OS software part numbers and hardware components supported by the Cisco MDS 9000 Family.


Note To use the Cisco Storage Services Enabler package, Cisco MDS SAN-OS Release 1.3(5) or later must be installed on the MDS switch.


Table 2 Cisco MDS 9000 Family Supported Software and Hardware Components  

Component
Part Number
Description
Applicable Product

Software

M95S2K9-5.0.4c

MDS 9500 Supervisor/Fabric-2, NX-OS software

MDS 9500 Series only

M92S2K9-5.0.4c

MDS 9200 Supervisor/Fabric-2, NX-OS software

MDS 9222i Switch only

M91S2K9-5.0.4c

MDS 9100 Supervisor/Fabric-2, NX-OS software

MDS 9124 Switch and MDS 9134 Switch

M91S3K9-5.0.4c

MDS 9148 Supervisor/Fabric-3 NX-OS software

MDS 9148 Switch

SSI Interface

SSI-M9K9-504c

Storage Services Interface for NX-OS Release 5.0(4c)

MDS 9000 Family

Licenses

M9500SSE184K9

Storage Services Enabler License for one MSM-18/4 module

MDS 9500 Series only

M9222ISSE1K9

Storage Services Enabler License

MDS 9222i Switch only

M9200SSE184K9

Storage Services Enabler License for one MSM-18/4 module

MDS 9200 Series only

M95DMM184K9

Data Mobility Manager License for one MSM-18/4 module

MDS 9500 Series only

M9222IDMMK9

Data Mobility Manager License for Cisco MDS 9222i

MDS 9222i Switch

M92DMM184K9

Data Mobility Manager License for one MSM-18/4 module

MDS 9200 Series only

Licenses (continued)

M95DMM184TSK9

Data Mobility Manager for one MSM-18/4 module — Time Limited to 180 days only

MDS 9500 Series only

M9222IDMMTSK9

Data Mobility Manager — Time Limited to 180 days only

MDS 9222i Switch only

M92DMM184TSK9

Data Mobility Manager for one MSM-18/4 module — Time Limited to 180 days only

MDS 9200 Series only

M92SSESSNK9

Cisco Storage Services Enabler License for SSN-16
(1 engine)

MDS 9200 Series only

M95SSESSNK9

Cisco Storage Services Enabler License for SSN-16
(1 engine)

MDS 9500 Series only

M92SMESSNK9

Cisco Storage Media Encryption License for SSN-16
(1 engine)

MDS 9200 Series only

M95SMESSNK9

Cisco Storage Media Encryption License for SSN-16
(1 engine)

MDS 9500 Series only

M92IOASSN

Cisco I/O Accelerator License for SSN-16 (1 engine)

MDS 9200 Series only

M95IOASSN

Cisco I/O Accelerator License for SSN-16 (1 engine)

MDS 9500 Series only

M92IOA184

Cisco I/O Accelerator License for MSM-18/4

MDS 9200 Series only

M95IOA184

Cisco I/O Accelerator License for MSM-18/4

MDS 9500 Series only

M9222IIOA

Cisco I/O Accelerator License for Cisco MDS 9222i base switch

MDS 9222i Switch only

M92EXTSSNK9

Cisco SAN Extension License for SSN-16 (1 engine)

MDS 9200 Series only

M95EXTSSNK9

Cisco SAN Extension License for SSN-16 (1 engine)

MDS 9500 Series only

M9200XRC

Cisco XRC Acceleration

MDS 9200 Series only

M9500XRC

Cisco XRC Acceleration

MDS 9500 Series only

Chassis

DS-C9513

Cisco MDS 9513 Multilayer Director (13-slot multilayer director with 2 slots for Supervisor-2 modules, with 11 slots available for switching modules — SFPs sold separately)

MDS 9513 Switch

DS-C9509

Cisco MDS 9509 Multilayer Director (9-slot multilayer director with 2 slots for Supervisor modules, with 7 slots available for switching modules — SFPs sold separately)

MDS 9509 Switch

DS-C9506

Cisco MDS 9506 Multilayer Director (6-slot multilayer director with 2 slots for Supervisor modules, with 4 slots available for switching modules — SFPs sold separately)

MDS 9506 Switch

DS-C9222i-K9

Cisco MDS 9222i Multilayer Fabric Switch (3-rack-unit (3RU) semimodular multilayer fabric switch with 18 4-Gbps Fibre Channel ports, 4 Gigabit Ethernet ports, and a modular expansion slot for Cisco MDS 9000 Family Switching and Services modules)

MDS 9222i Switch

DS-C9148-K9

Cisco MDS 9148 48-Port Multilayer Fabric Switch (1RU fixed-configuration multilayer fabric switch with 48 8-Gbps Fibre Channel ports)

MDS 9148 Switch

DS-C9134-K9

Cisco MDS 9134 34-Port Multilayer Fabric Switch (1RU fixed-configuration multilayer fabric switch with 32 4-Gbps and 2 10-Gbps Fibre Channel ports)

MDS 9134 Switch

DS-C9124-K9

Cisco MDS 9124 24-Port Multilayer Fabric Switch (1RU fixed-configuration multilayer fabric switch with 24 4-Gbps Fibre Channel ports)

MDS 9124 Switch

Supervisor Modules

DS-X9530-SF2-K9

Cisco MDS 9500 Series Supervisor-2 Module

MDS 9500 Series

DS-X9530-SF2A-K9

Cisco MDS 9500 Series Supervisor-2A Module

MDS 9500 Series

Switching Modules

DS-X9112

Cisco MDS 9000 12-port 4-Gbps Fibre Channel Switching Module with SFP LC connectors

MDS 9500 Series

MDS 9200 Series

DS-X9124

Cisco 24-port 4-Gbps Fibre Channel Switching Module with SFP LC connectors

MDS 9500 Series

MDS 9200 Series

DS-X9148

Cisco MDS 9000 48-port 4-Gbps Fibre Channel Switching Module with SFP LC

MDS 9500 Series

MdS 9200 Series

DS-X9704

Cisco MDS 9000 Family 4-Port 10-Gbps Fibre Channel Switching Module with SFP LC

MDS 9500 Series

MDS 9200 Series

DS-X9224-96K9

Cisco MDS 9000 24-Port 8-Gbps Fibre Channel Switching Module with SFP and SFP+ LC connectors

MDS 9500 Series

DS-X9248-96K9

Cisco MDS 9000 48-Port 8-Gbps Fibre Channel Switching Module with SFP and SFP+ LC connectors

MDS 9500 Series

DS-X9248-48K9

Cisco MDS 9000 4/44-Port Host-Optimized 8-Gbps Fibre Channel Switching Module with SFP and SFP+ LC connectors

MDS 9500 Series

MDS 9222i Switch

Services Modules

DS-X9316-SSNK9

Cisco MDS 9000 Family 16-Port Storage Services Node (SSN-16) — 16 fixed 1-Gbps Ethernet ports, plus 4 service engines that support 16 Gigabit Ethernet IP storage services ports.

MDS 9500 Series

MDS 9222i Switch

DS-X9304-18K9

Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4) — 18-port, 4-Gbps Fibre Channel plus 4-port Gigabit Ethernet IP services and switching module with SFP LC connectors

MDS 9500 Series

MDS 9200 Series

External crossbar module

DS-13SLT-FAB1

Cisco MDS 9513 Switching Fabric1 Module

MDS 9513 Switch

DS-13SLT-FAB2

Cisco MDS 9513 Switching Fabric2 Module

MDS 9513 Switch

Optics

DS-X2-FC10G-SR

X2 SC optics, 10-Gbps Fibre Channel for short reach

MDS 9500 Series
MDS 9200 Series
MDS 9134 Switch

DS-X2-FC10G-LR

X2 SC optics, 10-Gbps Fibre Channel for long reach (10 km)

MDS 9500 Series
MDS 9200 Series
MDS 9134 Switch

DS-X2-FC10G-ER

X2 SC optics, 10-Gbps Fibre Channel for extended reach (40 km)

MDS 9500 Series
MDS 9200 Series
MDS 9134 Switch

DS-X2-FC10G-CX4

X2 SC optics, 10-Gbps Fibre Channel over copper

MDS 9500 Series
MDS 9200 Series
MDS 9134 Switch

DS-X2-E10G-SR

X2 SC optics, 10-Gbps Ethernet for short reach

MDS 9500 Series
MDS 9200 Series

LC-type fiber-optic SFP

DS-SFP-FC8G-SW

SFP+ optics (LC type) for 2-, 4-, or 8-Gbps Fibre Channel for shortwave mode

MDS DS-X9200 Series switching modules

DS-SFP-FC8G-LW

SFP+ optics (LC type) for 2-, 4-, or 8-Gbps Fibre Channel for longwave mode; supports distances up to 10 km

MDS DS-X9200 Series switching modules

DS-SFP-FC4G-SW

SFP optics (LC type) for 1-, 2-, or 4-Gbps Fibre Channel for shortwave mode

MDS 9124, MDS 9134, MDS 9222i, DS-X9100, and DS-X9200 Series switching modules

DS-SFP-FC4G-MR

SFP optics (LC type) for 1-, 2-, or 4-Gbps Fibre Channel for longwave mode; supports distances up to 4 km

MDS 9124, MDS 9134, MDS 9222i, DS-X9100, and DS-X9200 Series switching modules

DS-SFP-FC4G-LW

SFP optics (LC type) for 1-, 2-, or 4-Gbps Fibre Channel for longwave mode; supports distances up to 10 km

MDS 9124, MDS 9134, MDS 9222i, DS-X9100, and DS-X9200 Series switching modules

DS-SFP-FC-2G-SW

SFP optics (LC type) for 1- or 2-Gbps Fibre Channel for shortwave mode; not supported for use in 4-Gbps-capable ports

MDS 9000 Series

DS-SFP-FC-2G-LW

SFP optics (LC type) for 1- or 2-Gbps Fibre Channel for longwave mode for Cisco MDS 9500, MDS 9200, and MDS 9100 Series; not supported for use in 4-Gbps-capable ports

MDS 9000 Series

DS-SFP-FCGE-SW

SFP optics (LC type) for 1-Gbps Ethernet and 1- or 2-Gbps Fibre Channel for shortwave mode; not supported for use in 4-Gbps-capable ports

MDS 9000 Series

DS-SFP-FCGE-LW

SFP optics (LC type) for 1-Gbps Ethernet and 1- or 2-Gbps Fibre Channel for longwave mode; not supported for use in 4-Gbps-capable ports

MDS 9000 Series

DS-SFP-GE-T

SFP (RJ-45 connector) for Gigabit Ethernet over copper

MDS 9000 Series

Cisco Coarse Wavelength- Division Multiplexing (CWDM)

DS-CWDM-xxxx

CWDM Gigabit Ethernet and 1- or 2-Gbps Fibre Channel SFP LC type, where product number xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm

MDS 9000 Family

DS-CWDM4Gxxxx

CWDM 4-Gbps Fibre Channel SFP LC type, where product number xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm

MDS 9000 Family

Dense Wavelength- Division Multiplexing (DWDM)

DWDM-X2-xx.xx

DWDM X2 SC optics for 10-Gbps Fibre Channel connectivity to an existing Ethernet DWDM infrastructure, with 15xx.xx nm wavelength, where xx.xx = 60.61, 59.79, 58.98, 58.17, 56.55, 55.75, 54.94, 54.13, 52.52, 51.72, 50.92, 50.12, 48.51, 47.72, 46.92, 46.12, 44.53, 43.73, 42.94, 42.14, 40.56, 39.77, 38.98, 38.19, 36.61, 35.82, 35.04, 34.25, 32.68, 31.90, 31.12, or 30.33

MDS 9500 Series

MDS 9200 Series

DWDM-SFP-xxxx

DWDM Gigabit Ethernet and 1- or 2-Gbps Fibre Channel SFP LC type, where product number xxxx = 3033, 3112, 3190, 3268, 3425, 3504, 3582, 3661, 3819, 3898, 3977, 4056, 4214, 4294, 4373, 4453, 4612, 4692, 4772, 4851, 5012, 5092, 5172, 5252, 5413, 5494, 5575, 5655, 5817, 5898, 5979, or 6061nm

MDS 9000 Family

Add/Drop Multiplexer (ADM)

DS-CWDMOADM4A

4-channel CWDM optical ADM (OADM) module (Cisco CWDM 1470, 1490, 1510, or 1530 NM Add/Drop Module)

MDS 9000 Family

DS-CWDMOADM4B

4-channel CWDM OADM module (Cisco CWDM 1550, 1570, 1590, or 1610 NM Add/Drop Module)

MDS 9000 Family

DS-CWDM-MUX8A

ADM for 8 CWDM wavelengths

MDS 9000 Family

CWDM Multiplexer Chassis

DS-CWDMCHASSIS

2-slot chassis for CWDM ADMs

MDS 9000 Family

Power Supplies

DS-CAC-300W

300W AC power supply

MDS 9100 Series

DS-C24-300AC

300W AC power supply

MDS 9124 Switch

DS-CAC-845W

845W AC power supply for Cisco MDS 9200 Series

MDS9200 Series

DS-CAC-3000W

3000W AC power supply for Cisco MDS 9509

MDS 9509 Switch

DS-CAC-2500W

2500W AC power supply

MDS 9509 Switch

DS-CDC-2500W

2500W DC power supply

MDS 9509 Switch

DS-CAC-6000W

6000W AC power supply for Cisco MDS 9513

MDS 9513 Switch

DS-CAC-1900W

1900W AC power supply for Cisco MDS 9506

MDS 9506 Switch

CompactFlash

MEM-MDS-FLD512M

External 512-MB CompactFlash memory for supervisor module

MDS 9500 Series

Port Analyzer Adapter

DS-PAA-2, DS-PAA

A standalone Fibre Channel-to-Ethernet adapter that allows for simple, transparent analysis of Fibre Channel traffic in a switched fabric

MDS 9000 Family

Smart Card Reader

DS-SCR-K9

Storage Media Encryption (SME) Smart Card Reader

MDS 9000 Family

Smart Card

DS-SC-K9

SME Smart Card

MDS 9000 Family

CD-ROM

M90FM-CD-441

Cisco MDS 9000 Management Software and Documentation CD-ROM for Cisco MDS 9000 NX-OS Software Release 4.1(3a)

MDS 9000 Family


MDS 9000 Chassis and Module Support

Table 3 lists the MDS hardware chassis supported by Cisco MDS NX-OS 5.x.

Table 3 Cisco MDS NX-OS 5.x Chassis Support Matrix 

Switch
NX-OS 5.x Support

MDS 9513

Yes

MDS 9509

Yes

MDS 9506

Yes

MDS 9222i

Yes

MDS 9148

Yes

MDS 9134

Yes

MD S 9124

Yes

Cisco Fabric Switch for HP c-Class BladeSystem and Cisco Fabric Switch for IBM BladeCenter

Yes



Note As of Cisco MDS NX-OS Release 5.0(1a), support for the MDS 9216i switch is discontinued.


Table 4 lists the MDS hardware modules supported by Cisco MDS NX-OS 5.x. For the list of MDS hardware modules supported by Cisco MDS SAN-OS 4.x, see Table 5. For the list of MDS hardware modules supported by Cisco MDS SAN-OS 3.x, see Table 6.


Note As of Cisco MDS NX-OS Release 5.0(1a), support for the following Generation 1 modules is discontinued:

DS-X9302-14K9, 14/2-port Multiprotocol Services (MPS-14/2) Module

DS-X9016, 16-port 1-, 2-Gbps Fibre Channel Switching Module

DS-X9032, 32-port 1-, 2-Gbps Fibre Channel Switching Module

DS-X9032SSM, 32-port Storage Services Module (SSM)

Remove Generation 1 modules from a switch chassis before start the installation of Cisco NX-OS Release 5.0(4c).


Table 4 Module Support Matrix for Cisco MDS NX-OS 5.x 

Module
Description
MDS 9500 Series
MDS 9222i

DS-X9530-SF2-K9

MDS 9500 Supervisor-2 Module

Yes

N/A

DS-X9530-SF2A-K9

MDS 9500 Supervisor-2A Module

Yes

N/A

DS-13SLT-FAB2

MDS 9513 Fabric Module 2

Yes

N/A

DS-13SLT-FAB1

MDS 9513 Fabric Module 1

Yes

N/A

DS-X9224-96K9

24-port 8-Gbps Fibre Channel Switching Module

Yes1

No

DS-X9248-96K9

48-port 8-Gbps Fibre Channel Switching Module

Yes2

No

DS-X9248-48K9

4/44-port Host Optimized8-Gbps Fibre Channel Switching Module

Yes

Yes

DS-X9316-SSNK9

16-port Storage Services Node (SSN-16)

Yes

Yes

DS-X9304-18K9

18/4-Port Multiservice Module (MSM-18/4)

Yes

Yes

DS-X9112

12-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

DS-X9124

24-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

DS-X9148

48-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

DS-X9704

4-port 10-Gbps Fibre Channel Switching Module

Yes

Yes

1 Requires DS-13SLT-FAB2 in the MDS 9513.


Table 5 lists the MDS hardware modules supported by Cisco MDS NX-OS 4.x. For the list of MDS hardware modules supported by Cisco MDS SAN-OS 3.x, see Table 6.

Table 5 Module Support Matrix for Cisco MDS NX-OS 4.x 

Module
Description
MDS 9500 Series
MDS 9222i
MDS 9216i

DS-X9530-SF2-K9

MDS 9500 Supervisor-2 Module

Yes

N/A

N/A

DS-X9530-SF2A-K9

MDS 9500 Supervisor-2A Module

Yes1

N/A

N/A

DS-X9530-SF1-K9

MDS 9500 Supervisor-1 Module

No

N/A

N/A

DS-13SLT-FAB2

MDS 9513 Fabric Module 2

Yes

N/A

N/A

DS-13SLT-FAB1

MDS 9513 Fabric Module 1

Yes

N/A

N/A

DS-X9224-96K9

24-port 8-Gbps Fibre Channel Switching Module

Yes2

No

No

DS-X9248-96K9

48-port 8-Gbps Fibre Channel Switching Module

Yes2

No

No

DS-X9248-48K9

4/44-port Host Optimized8-Gbps Fibre Channel Switching Module

Yes

Yes

No

DS-X9316-SSNK9

16-port Storage Services Node (SSN-16)

Yes

Yes

Yes

DS-X9304-18K9

18/4-Port Multiservice Module (MSM-18/4)

Yes

Yes

Yes

DS-X9112

12-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

DS-X9124

24-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

DS-X9148

48-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

DS-X9704

4-port 10-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

DS-X9302-14K9

14/2-port Multiprotocol Services (MPS-14/2) Module

Yes

No

Yes

DS-X9016

16-port 1-, 2-Gbps Fibre Channel Switching Module

Yes

No

Yes

DS-X9032

32-port 1-, 2-Gbps Fibre Channel Switching Module

Yes

No

Yes

DS-X9032-SSM

32-port Storage Services Module (SSM)

Yes

Yes

Yes

DS-X9308-SMIP

8-port 1-, 2-Gbps IP Switching Module

No

No

No

DS-X9304-SMIP

4-port 1-, 2-Gbps IP Switching Module

No

No

No

1 In software releases earlier than Cisco NX-OS Release 4.2(7a), the Supervisor-2A module appears as unsupported hardware in Device Manager, but the Supervisor-2A module does work with Cisco NX-OS release 4.x software.

2 Requires DS-13SLT-FAB2 in the MDS 9513.


Table 6 lists the MDS hardware modules supported by Cisco MDS SAN-OS 3.x.

Table 6 Module Support Matrix for Cisco MDS SAN-OS 3.x 

Module
Description
MDS 9500 Series
MDS 9222i
MDS 9216i
MDS 9216A
MDS 9216

DS-X9530-SF2-K9

MDS 9500 Supervisor-2 Module

Yes

N/A

N/A

N/A

N/A

DS-X9530-SF2A-K9

MDS 9500 Supervisor-2A Module

Yes1

N/A

N/A

N/A

N/A

DS-X9530-SF1-K9

MDS 9500 Supervisor-1 Module

Yes

N/A

N/A

N/A

N/A

DS-13SLT-FAB2

MDS 9513 Fabric Module 2

Yes

N/A

N/A

N/A

N/A

DS-13SLT-FAB1

MDS 9513 Fabric Module 1

Yes

N/A

N/A

N/A

N/A

DS-X9224-96K9

24-port 8-Gbps Fibre Channel Switching Module

No

No

No

No

No

DS-X9248-96K9

48-port 8-Gbps Fibre Channel Switching Module

No

No

No

No

No

DS-X9248-48K9

4/44-port Host Optimized8-Gbps Fibre Channel Switching Module

No

No

No

No

No

DS-X9316-SSNK9

16-port Storage Services Node (SSN-16)

No

No

No

No

No

DS-X9304-18K9

18/4-Port Multiservice Module (MSM-18/4)2

Yes

Yes

Yes

Yes

No

DS-X9112

12-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

Yes

No

DS-X9124

24-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

Yes

No

DS-X9148

48-port 4-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

Yes

No

DS-X9704

4-port 10-Gbps Fibre Channel Switching Module

Yes

Yes

Yes

Yes

No

DS-X9302-14K9

14/2-port Multiprotocol Services (MPS-14/2) Module

Yes

No

Yes

Yes

Yes

DS-X9016

16-port 1-, 2-Gbps Fibre Channel Switching Module

Yes

No

Yes

Yes

Yes

DS-X9032

32-port 1-, 2-Gbps Fibre Channel Switching Module

Yes

No

Yes

Yes

Yes

DS-X9032-SSM

32-port Storage Services Module (SSM)

Yes

Yes

Yes

Yes

Yes

DS-X9308-SMIP

8-port 1-, 2-Gbps IP Switching Module

Yes

No

Yes

Yes

Yes

DS-X9304-SMIP

4-port 1-, 2-Gbps IP Switching Module

Yes

Yes

Yes

Yes

Yes

1 In software releases earlier than Cisco NX-OS Release 3.3(5a), the Supervisor-2A module appears as unsupported hardware in Device Manager, but the Supervisor-2A module does work with Cisco NX-OS release 3.x software.

2 Cisco SAN-OS Release 3.2(1) and later support the 18/4-Port Multiservice Module (MSM-18/4).


Migrating from Supervisor-1 Modules to Supervisor-2 Modules

As of Cisco MDS SAN-OS Release 3.0(1), the Cisco MDS 9509 and 9506 Directors support both Supervisor-1 and Supervisor-2 modules. Supervisor-1 and Supervisor-2 modules cannot be installed in the same switch, except during migration. Both the active and standby supervisor modules must be of the same type, either Supervisor-1 or Supervisor-2 modules. For Cisco MDS 9513 Directors, both supervisor modules must be Supervisor-2 modules.


Caution Migrating your supervisor modules is a disruptive operation.


Note Migrating from Supervisor-2 modules to Supervisor-1 modules is not supported.


To migrate from a Supervisor-1 module to a Supervisor-2 module, refer to the step-by-step instructions in the Cisco MDS 9000 NX-OS Release 4.1(x) and SAN-OS 3(x) Software Upgrade and Downgrade Guide.

Software Download Process

Use the software download procedure to upgrade to a later version, or downgrade to an earlier version, of an operating system. This section describes the software download process for the Cisco MDS NX-OS software and includes the following topics:

Determining the Software Version

Determining Software Version Compatibility

Downloading Software

Selecting the Correct Software Image for an MDS 9100 Series Switch

Selecting the Correct Software Image for an MDS 9200 Series Switch

Selecting the Correct Software Image for an MDS 9500 Series Switch

Determining the Software Version

To determine the version of Cisco MDS NX-OS or SAN-OS software currently running on a Cisco MDS 9000 Family switch using the CLI, log in to the switch and enter the show version EXEC command.

To determine the version of Cisco MDS NX-OS or SAN-OS software currently running on a Cisco MDS 9000 Family switch using the Fabric Manager, view the Switches tab in the Information pane, locate the switch using the IP address, logical name, or WWN, and check its version in the Release column.

Determining Software Version Compatibility

Table 7 lists the software versions that are compatible in a mixed SAN environment, the minimum software versions that are supported, and the versions that have been tested. We recommend that you use the latest software release supported by your vendor for all Cisco MDS 9000 Family products.

Table 7 Software Release Compatibility

NX-OS Software
Minimum NX-OS or SAN-OS Release
Tested NX-OS and SAN-OS Releases

NX-OS Release 5.0(4c)

SAN-OS Release 3.3(1c) or later

SAN-OS Releases 3.3(1c), 3.3(5)

NX-OS Release 4.1(1b) or later

NX-OS Releases 4.1(1b), 4.2(7a)

 
Fabric Manager Software
Minimum NX-OS or SAN-OS Release
Tested NX-OS and SAN-OS Releases

Fabric Manager Release 5.0(4b)

SAN-OS Release 3.3(1c) or later

SAN-OS Release 3.3(1c), 3.3(5)

NX-OS Release 4.1(1b) or later

NX-OS Release 4.1(1b), 4.2(7a)

NX-OS Release 5.0(4c) or later

NX-OS Release 5.0(4c)


Downloading Software

The Cisco MDS NX-OS software is designed for mission-critical high availability environments. To realize the benefits of nondisruptive upgrades on the Cisco MDS 9500 Directors, we highly recommend that you install dual supervisor modules.

To download the latest Cisco MDS NX-OS software, access the Software Center at this URL:

http://www.cisco.com/public/sw-center

See the following sections in this release note for details on how you can nondisruptively upgrade your Cisco MDS 9000 switch. Issuing the install all command from the CLI, or using Fabric Manager to perform the downgrade, enables the compatibility check. The check indicates if the upgrade can happen nondisruptively or disruptively depending on the current configuration of your switch and the reason.

Compatibility check is done:
Module  bootable          Impact  Install-type  Reason
------  --------  --------------  ------------  ------
     1       yes  non-disruptive       rolling
     2       yes      disruptive       rolling  Hitless upgrade is not supported
     3       yes      disruptive       rolling  Hitless upgrade is not supported
     4       yes  non-disruptive       rolling
     5       yes  non-disruptive         reset
     6       yes  non-disruptive         reset
 
   

At a minimum, you need to disable the default device alias distribution feature using the no device-alias distribute command in global configuration mode. The show incompatibility system bootflash:system image filename command determines which additional features need to be disabled.


Note If you would like to request a copy of the source code under the terms of either GPL or LGPL, please send an e-mail to mds-software-disclosure@cisco.com.


Selecting the Correct Software Image for an MDS 9100 Series Switch

The system and kickstart image that you use for an MDS 9100 series switch depends on which switch you use, as shown in Table 8.

Table 8 Software Images for MDS 9100 Series Switches

Cisco MDS 9100 Series Switch Type
Naming Convention

MDS 9134, 9124, Cisco Fabric Switch for HP c-Class BladeSystem, Cisco Fabric Switch for IBM BladeCenter

Filename begins with m9100-s2ek9

MDS 9148

Filename begins with m9100-s3ek9


Selecting the Correct Software Image for an MDS 9200 Series Switch

The system and kickstart image that you use for an MDS 9200 series switch depends on which switch you use, as shown in Table 9.

Table 9 Software Images for MDS 9200 Series Switches

Cisco MDS 9200 Series Switch Type
Naming Convention

MDS 9222i

Filename begins with m9200-s2ek9


Selecting the Correct Software Image for an MDS 9500 Series Switch

The system and kickstart image that you use for an MDS 9500 Series are for switches with a Supervisor-2 module, as shown in Table 10. Cisco NX-OS Release 5.x and Release 4.x do not support the Supervisor-1 module.

Table 10 Software Images for Supervisor Type

Cisco MDS 9500 Series Switch Type
Supervisor Module Type
Naming Convention

MDS 9513, 9509, and 9506

Supervisor-2 module
Supervisor-2A module

Filename begins with m9500-sf2ek9


Use the show module command to display the type of supervisor module in the switch. The following is sample output from the show module command on a Supervisor 2 module:

switch# show module
Mod  Ports  Module-Type                      Model              Status
---  -----  -------------------------------- ------------------ ------------
...
...
7    0      Supervisor/Fabric-2              DS-X9530-SF2-K9    active *
8    0      Supervisor/Fabric-2              DS-X9530-SF2-K9    ha-standby
 
   

Upgrading Your Cisco MDS NX-OS Software Image

This section lists the guidelines recommended for upgrading your Cisco MDS NX-OS software image and includes the following topics:

General Upgrading Guidelines

Upgrading Effect on VSAN 4079

FICON Supported Releases and Upgrade Paths

Upgrading with IVR Enabled

Upgrading a Cisco MDS 9124 or Cisco MDS 9134 Switch

Upgrading a Cisco MDS 9124 or Cisco MDS 9134 Switch

Performing a Disruptive Upgrade on an MDS 9000 Family Switch

Resetting SNMP Notifications

Converting Automatically Created PortChannels Before an Upgrade


Note Before you begin the upgrade process, review the list of chassis and modules that Cisco MDS NX-OS Release 5.0(4c) supports. See the "MDS 9000 Chassis and Module Support" section.


For detailed instructions for performing a software upgrade using Cisco Fabric Manager, see the Cisco Fabric Manager Release Notes for Release 4.2(1a), which is available from the following website:

http://www.cisco.com/en/US/products/ps10495/prod_release_notes_list.html

General Upgrading Guidelines


Note To upgrade to Cisco NX-OS Release 5.0(4c) from SAN-OS Release 3.2(3a) or earlier, first upgrade to SAN-OS Release 3.3(x), then upgrade to Cisco NX-OS Release 4.1(x) or 4.2(x), and then upgrade to Cisco NX-OS Release 5.0(4c).


Use the following guidelines when upgrading to Cisco MDS NX-OS Release 5.0(4c):

Install and configure dual supervisor modules.

Issue the show install all impact upgrade-image CLI command to determine if your upgrade will be nondisruptive.

Follow the recommended guidelines for upgrading a Cisco MDS 9124 or MDS 9134 Switch as described in "Upgrading a Cisco MDS 9124 or Cisco MDS 9134 Switch" section.

Follow the guidelines for upgrading a single supervisor switch as described in "Performing a Disruptive Upgrade on an MDS 9000 Family Switch" section.

Be aware of the impact of an upgrade on VSAN 4079 if you are upgrading from SAN-OS Release 3.x to NX-OS 5.0(4c). See the "Upgrading Effect on VSAN 4079" section for details.

Be aware that some features impact whether an upgrade is disruptive or nondisruptive:

Fibre Channel Ports: Fibre Channel ports can be nondisruptively upgraded without affecting traffic on the ports. See Table 11 for the nondisruptive upgrade path for all NX-OS and SAN-OS releases.

SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write acceleration, is disrupted during an upgrade. SSM Fibre Channel traffic is not.

Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during an upgrade or downgrade. This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the upgrade is in progress.

Inter-VSAN Routing (IVR): With IVR enabled, you must follow additional steps if you are upgrading from Cisco SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the "Upgrading with IVR Enabled" section for these instructions.

FICON: If you have FICON enabled, the upgrade path is different. See the "FICON Supported Releases and Upgrade Paths" section.


Note In addition to these guidelines, you may want to review the information in the "Limitations and Restrictions" section prior to a software upgrade to determine if a feature may possibly behave differently following the upgrade.


Use Table 11 to determine your nondisruptive upgrade path to Cisco MDS NX-OS Release 5.0(4c), find the image release number you are currently using in the Current column of the table, and use the path recommended.


Note The software upgrade information in Table 11 applies only to Fibre Channel switching traffic. Upgrading system software disrupts IP traffic and SSM intelligent services traffic.


Table 11 Nondisruptive Upgrade Path to Cisco MDS NX-OS Release 5.0(4c) 

Current Release
Nondisruptive Upgrade Path and Ordered Upgrade Steps

NX-OS:

Release 5.0(4b), Release 5.0(4), and all 5.0(1x) releases.

Upgrade to NX-OS Release 5.0(4c).1

All 4.2(x) releases

Upgrade to NX-OS Release 5.0(4c).

All 4.1(x) releases

Upgrade to NX-OS Release 5.0(4c).

SAN-OS:

Release 3.3(1c), 3.3(2), 3.3(3), 3.3(4x), and 3.3(5x).

1. Upgrade to NX-OS Release 4.1(x) or 4.2(x).

2. Upgrade to NX-OS Release 5.0(4c).

Release 3.2(1a), all 3.2(x), 3.1(x), and 3.0(x) releases, and release 2.1(3), 2.1(2e), 2.1(2d), and 2.1(2b)

1. Upgrade to SAN-OS Release 3.3(1c).

2. Upgrade to NX-OS Release 4.1(x) or 4.2(x).

3. Upgrade to NX-OS Release 5.0(4c).

Release 2.1(2), 2.1(1b), 2.1(1a), and
2.0(x)

1. Upgrade to SAN-OS Release 2.1(2b), 2.1(2d), 2.1(2e), or 2.1(3).

2. Upgrade to SAN-OS Release 3.3(1c).

3. Upgrade to NX-OS Release 4.1(x) or 4.2(x).

4. Upgrade to NX-OS Release 5.0(4c).

Release 1.x

1. Upgrade to SAN-OS Release 1.3(4a).

2. Upgrade to SAN-OS Release 2.1(2b).

3. Upgrade to SAN-OS Release 3.3(1c).

4. Upgrade to NX-OS Release 4.1(x) or 4.2(x).

5. Upgrade to NX-OS Release 5.0(4c).

1 See Table 14 before you begin a software upgrade on a Cisco MDS 9509 or MDS 9506 switch.


FICON Supported Releases and Upgrade Paths

Cisco MDS NX-OS Release 5.0(4c) does not support FICON

Table 12 lists the SAN-OS and NX-OS releases that support FICON. Refer to the specific release notes for FICON upgrade path information.

Table 12 FICON Supported Releases 

FICON Supported Releases

NX-OS

Release 4.2(1b)

Release 4.1(1c)

SAN-OS

Release 3.3(1c)

Release 3.2(2c)

Release 3.0(3b)

Release 3.0(3)

Release 3.0(2)

Release 2.0(2b)


Use Table 13 to determine your FICON nondisruptive upgrade path to Cisco MDS NX-OS Release 5.0 Find the image release number you are currently using in the Current Release with FICON Enabled column of the table and follow the recommended path.

Table 13 FICON Nondisruptive Upgrade Path to MDS NX-OS Release 4.2(1b)  

Current Release with FICON Enabled
Upgrade Path

NX-OS 4.1(1c)

You can nondisruptively upgrade directly to NX-OS Release 4.2(1b).

SAN-OS 3.3(1c)

You can nondisruptively upgrade directly to NX-OS Release 4.2(1b).

SAN-OS 3.2(2c)

First upgrade to SAN-OS Release 3.3(1c), and then upgrade to NX-OS Release 4.2(1b).

SAN-OS 3.0(3b)

SAN-OS 3.0(3)

SAN-OS 3.0(2)

SAN-OS 2.0(2b)

Use the interface shutdown command to administratively shut any Fibre Channel ports on Generation 1 modules that are in an operationally down state before nondisruptively upgrading from SAN-OS Release 2.0(2b) to SAN-OS Release 3.0(2) or SAN-OS Release 3.0(3b), and then upgrade to Release 3.3(1c). An operationally down state includes Link failure or not-connected, SFP not present, or Error Disabled status in the output of a show interface command. When an interface is administratively shut it will then show as Administratively down. Interfaces that are currently up or trunking do not need to be shut down.

SAN-OS 1.x

Upgrade to SAN-OS Release 3.0(2). Use the interface shutdown command to shut all the ports operationally down and administratively up on all the Generation 1 modules before nondisruptively upgrading to Release 2.0(2b) and then upgrade to 1.3(4a).


Upgrading Effect on VSAN 4079

If you upgrade to NX-OS Release 5.0(4c), and you have not created VSAN 4079, the NX-OS software will automatically create VSAN 4079 and reserve it for EVFP use.

If VSAN 4079 is reserved for EVFP use, the switchport trunk allowed vsan command will filter out VSAN 4079 from the allowed list. In the following example, the allowed list appears on a separate line following the command:

switch(config-if)# switchport trunk allowed vsan 1-4080
1-4078,4080

switch(config-if)#

If you have created VSAN 4079, the upgrade to NX-OS Release 5.0(4c) will have no affect on VSAN 4079.

If you downgrade to a release of NX-OS lower than NX-OS Release 4.1(x) after NX-OS Release 5.0(4c) creates VSAN 4079 and reserves it for EVFP use, the VSAN will no longer be reserved.

Upgrading with IVR Enabled

An Inter-Switch Link (ISL) flap resulting in fabric segmentation or a merge during or after an upgrade from Cisco MDS SAN-OS Release 2.0(x) to a later image where IVR is enabled might be disruptive. Some possible scenarios include the following:

FCIP connection flapping during the upgrade process resulting in fabric segmentation or merge.

ISL flap results in fabric segmentation or merge because of hardware issues or a software bug.

ISL port becomes part of PCP results in fabric segmentation or merge because of a port flap.

If this problem occurs, syslogs indicate a failure and the flapped ISL could remain in a down state because of a domain overlap.

This issue was resolved in Cisco SAN-OS Release 2.1(2b); you must upgrade to Release 2.1(2b) before upgrading to Release 3.3(1c). An upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) when IVR is enabled requires that you follow the procedure below. If you have VSANs in interop mode 2 or 3, you must issue an IVR refresh for those VSANs.

To upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) for all other VSANs with IVR enabled, follow these steps:


Step 1 Configure static domains for all switches in all VSANs where IVR is enabled. Configure the static domain the same as the running domain so that there is no change in domain IDs. Make sure that all domains are unique across all of the IVR VSANs. We recommend this step as a best practice for IVR-non-NAT mode. Issue the fcdomain domain id static vsan vsan id command to configure the static domains.


Note Complete Step 1 for all switches before moving to Step 2.


Step 2 Issue the no ivr virtual-fcdomain-add vsan-ranges vsan-range command to disable RDI mode on all IVR enabled switches. The range of values for a VSAN ID is 1 to 4093. This can cause traffic disruption.


Note Complete Step 2 for all IVR enabled switches before moving to Step 3.


Step 3 Check the syslogs for any ISL that was isolated.

2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: 
%$VSAN 2005%$ Isolation of interface 
PortChannel 52 (reason: unknown failure)
2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: %$VSAN 2005%$ 
Isolation of interface PortChannel 51 
(reason: domain ID assignment failure)
 
   

Step 4 Issue the following commands for the isolated switches in Step 3:

switch(config)# vsan database
switch(config-vsan-db)# vsan vsan-id suspend
switch(config-vsan-db)# no vsan vsan-id suspend
 
   

Step 5 Issue the ivr refresh command to perform an IVR refresh on all the IVR enabled switches.

Step 6 Issue the copy running-config startup-config command to save the RDI mode in the startup configuration on all of the switches.

Step 7 Follow the normal upgrade guidelines for Release 2.1(2b). If you are adding new switches running Cisco MDS SAN-OS Release 2.1(2b) or later, upgrade all of your existing switches to Cisco SAN-OS Release 2.1(2b) as described in this workaround. Then follow the normal upgrade guidelines for Release 3.3(1c).


Note RDI mode should not be disabled for VSANs running in interop mode 2 or interop mode 3.



Upgrading a Cisco MDS 9124 or Cisco MDS 9134 Switch

If you are upgrading from Cisco MDS SAN-OS Release 3.1(1) to Cisco NX-OS Release 4.2(1b) before upgrading to NX-OS Release 5.0(4c) on a Cisco MDS 9124 or MDS 9134 Switch, follow these guidelines:

During the upgrade, configuration is not allowed and the fabric is expected to be stable.

The Fabric Shortest Path First (FSPF) timers must be configured to the default value of 20 seconds; otherwise, the nondisruptive upgrade is blocked to ensure that the maximum down time for the control plane can be 80 seconds.

If there are any CFS commits in the fabric, the nondisruptive upgrade will fail.

If there is a zone server merge in progress in the fabric, the nondisruptive upgrade will fail.

If a service terminates the nondisruptive upgrade, the show install all failure-reason command can display the reason that the nondisruptive upgrade cannot proceed.

If there is not enough memory in the system to load the new images, the upgrade will be made disruptive due to insufficient resources and the user will be notified in the compatibility table.

Performing a Disruptive Upgrade on an MDS 9000 Family Switch

If you do not follow the upgrade path when performing a disruptive upgrade on an MDS 9000 Family switch, (for example, you upgrade directly from SAN-OS Release 2.1(2) or earlier version to NX-OS Release 4.2(x)), the binary startup configuration is deleted because it is not compatible with the new image, and the ASCII startup configuration file is applied when the switch comes up with the new upgraded image. When the ASCII startup configuration file is applied, there may be errors. Because of this, we recommend that you follow the nondisruptive upgrade path.


Note You cannot upgrade the software image on an MDS 9120 switch, an MDS 9140 switch, or an MDS 9216i switch to Cisco NX-OS Release 5.x. See Table 3 for the list of switches that support Cisco NX-OS Release 5.0(4c).


Resetting SNMP Notifications

Following a software upgrade or downgrade, SNMP notifications will reset as follows:

When you upgrade from SAN-OS Release 3.x to NX-OS Release 4.1(x), and then to NX-OS Release 5.x, SNMP notifications will reset to their default settings.

When you upgrade from SAN-OS Release 3.x to NX-OS Release 4.2(x), and then to NX-OS Release 5.x, SNMP notifications will not reset to their default settings.

When you downgrade from any NX-OS Release 4.2(x), SNMP notifications will reset to their default configuration settings.

Use the snmp-server enable traps command to reenable your required SNMP notifications.

Converting Automatically Created PortChannels Before an Upgrade

Before upgrading from NX-OS Release 4.1(x) or 4.2(x) to Release 5.x, ensure that you do not have any automatically created PortChannels present in the switch configuration. Use the port-channel persistent command to convert an automatically created PortChannel to a persistent PortChannel. Failure to convert automatically created PortChannels prior to the upgrade can result in traffic disruption because Autocreation of PortChannels is a deprecated feature as of NX-OS Release 4.1(1b).

Downgrading Your Cisco MDS SAN-OS Software Image

This section lists the guidelines recommended for downgrading your Cisco MDS SAN-OS software image and includes the following topics:

General Downgrading Guidelines

New Features in Cisco MDS NX-OS Release 5.0(4c)

NX-OS Release 5.0(x) Software Downgrade and Upgrade Matrix for Cisco MDS 9509 and 9506 Switches

General Downgrading Guidelines

Use the following guidelines to nondisruptively downgrade your Cisco MDS NX-OS Release 5.0(4c):

Install and configure dual supervisor modules.

Issue the system no acl-adjacency-sharing execute command to disable ACL adjacency usage on Generation 2 and Generation 1 modules. If this command fails, reduce the number of zones, IVR zones, TE ports, or a combination of these in the system and issue the command again.

Disable all features not supported by the downgrade release. Use the show incompatibility system downgrade-image command to determine what you need to disable.

Use the show install all impact downgrade-image command to determine if your downgrade will be nondisruptive.

Be aware that some features impact whether a downgrade is disruptive or nondisruptive:

Fibre Channel Ports: Fibre Channel ports can be nondisruptively downgraded without affecting traffic on the ports. See Table 15 for the nondisruptive downgrade path for all SAN-OS releases.

SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write acceleration, is disrupted during a downgrade. SSM Fibre Channel traffic is not.

Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during a downgrade. This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the downgrade is in progress.

IVR: With IVR enabled, you must follow additional steps if you are downgrading from Cisco SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the "Upgrading with IVR Enabled" section for these instructions.

FICON: If you have FICON enabled, the downgrade path is different. See the "FICON Downgrade Paths" section.


Note A downgrade from NX-OS Release 4.2(1b) to SAN-OS Release 3.3(1x) is not supported on MDS switches, when FC-Redirect based applications, such as Data Mobility Manager or Storage Media Encryption, are configured in the fabric if either of the following conditions are satisfied:

1. A target for which FC-Redirect is configured is connected locally and there are Generation 1 modules with ISLs configured in the switch.

2. A host, for which FC-redirect is configured, is connected locally on a Generation 1 module.

If these conditions exist, remove the application configuration for these targets and hosts before proceeding with the downgrade.


NX-OS Release 5.0(x) Software Downgrade and Upgrade Matrix for Cisco MDS 9509 and 9506 Switches

See the compatibility information in Table 14 to determine if a downgrade to, or upgrade from Release 5.0(x) software is disruptive or nondisruptive on a Cisco MDS 9509 or 9506 switch.

Table 14 NX-OS Release 5.0(x) Downgrade and Upgrade Matrix

Downgrade Path on a Cisco MDS 9509 or 9506 Switch
Current Release
Desired Release
Expected Behavior
Observed Behavior

5.0(7) or 5.0(8)

5.0(1a), 5.0(1b), or 5.0(4)

Disruptive

Nondisruptive
The user is expected to explicitly reload the switch using the reload command.

5.0(7) or 5.0(8)

4.2(x) or 4.1(x)

Disruptive

Disruptive

5.0(4)

5.0(1a)

Nondisruptive

Nondisruptive

5.0(1a), 5.0(1b), or 5.0(4)

4.2(x) or 4.1(x)

Nondisruptive

Nondisruptive

 
Upgrade Path on a Cisco MDS 9509 or 9506 Switch
Current Release
Desired Release
Expected Behavior
Observed Behavior

5.0(7) or 5.0(8)

5.2(x)

Nondisruptive
Support for Generation 4 modules is available.

Nondisruptive
Support for Generation 4 modules is available.

5.0(1a), 5.0(1b), or 5.0(4)

5.2(x)

Nondisruptive
Support for Generation 4 modules is not available.

Nondisruptive
Support for Generation 4 modules is not available.


Use Table 15 to determine the nondisruptive downgrade path from Cisco NX-OS Release 5.0(4c). Find the SAN-OS image you want to downgrade to in the To SAN-OS Release column of the table and use the path recommended.


Note The software downgrade information in Table 15 applies only to Fibre Channel switching traffic. Downgrading system software disrupts IP and SSM intelligent services traffic.


Table 15 Nondisruptive Downgrade Path from NX-OS Release 5.0(4c) 

To NX-OS or SAN-OS Release
Nondisruptive Downgrade Path and Ordered Downgrade Steps

NX-OS:

Release 5.0(4b), 5.0(4), and all 5.0(1x) releases

Downgrade directly from NX-OS Release 5.0(4c).1

All 4.2(x) and 4.1(x) releases

Downgrade to NX-OS Release 4.2(x) or 4.1(x).

SAN-OS:

All 3.3(x) releases

1. Downgrade to NX-OS Release 4.2(x) or Release 4.1(x).

2. Downgrade to SAN-OS Release 3.3(x).

All 3.2(x), 3.1(x), 3.0(x) releases, and all 2.1(x) releases.

1. Downgrade to NX-OS Release 4.2(x) or Release 4.1(x).

2. Downgrade to SAN-OS Release 3.3(x).

3. Downgrade to SAN-OS Release 3.2(x), Release 3.1(x)., Release 3.0(x), or Release 2.1(x).

All 2.0(x) releases.

1. Downgrade to NX-OS Release 4.2(x) or Release 4.1(x).

2. Downgrade to SAN-OS Release 3.3(x).

3. Downgrade to SAN-OS Release 2.1(2x).

4. Downgrade to SAN-OS Release 2.0(x).

Release 1.x

1. Downgrade to NX-OS Release 4.2(x) or Release 4.1(x).

2. Downgrade to SAN-OS Release 3.3(x).

3. Downgrade to SAN-OS Release 2.1(2b).

4. Downgrade to SAN-OS Release 1.3(4a).

5. Downgrade to SAN-OS Release 1.x.

1 See Table 14 before you perform a software downgrade on a Cisco MDS 9509 or MDS 9506 switch.


FICON Downgrade Paths

Table 16 lists the downgrade paths for FICON releases. Find the image release number that you want to downgrade to in the To Release with FICON Enabled column of the table and follow the recommended downgrade path.

Table 16 FICON Downgrade Path from NX-OS Release 4.1(1c) 

To Release with FICON Enabled
Downgrade Path

SAN-OS 3.3(1c)

You can nondisruptively downgrade directly from NX-OS Release 4.1(1c).

SAN-OS 3.2(2c)

First downgrade to SAN-OS Release 3.3(1c) and then downgrade to Release 3.2(2c).

SAN-OS 3.0(3b)

First downgrade to SAN-OS Release 3.3(1c) and then downgrade to Release 3.0(3b).

SAN-OS 3.0(2)

First downgrade to SAN-OS Release 3.3(1c) and then downgrade to Release 3.0(2).

SAN-OS 2.0(2b)

Use the interface shutdown command to administratively shut any Fibre Channel ports on Generation 1 modules that are in an operationally down state before nondisruptively downgrading from NX-OS Release 4.1 to SAN-OS Release 3.3(1c) then to SAN-OS Release 3.0(3b) or SAN-OS Release 3.0(2), and then to SAN-OS Release 2.0(2b). An operationally down state includes Link failure or not-connected, SFP not present, or Error Disabled status in the output of a show interface command. When an interface is administratively shut it will then show as Administratively down. Interfaces that are currently up or trunking do not need to be shut down.

SAN-OS 1.3(4a)

Downgrade to SAN-OS Release 3.3(1c) and then to Release 3.0(2). Use the shutdown command to shut all the ports operationally down and administratively up on all the Generation 1 modules before nondisruptively downgrading to Release 2.0(2b) and then downgrade to 1.3(4a).


New Features in Cisco MDS NX-OS Release 5.0(4c)

Cisco MDS NX-OS Release 5.0(4c) is a maintenance release that fixes issues associated with the Cisco Call Home feature and the Port Monitor feature.

Licensed Cisco NX-OS Software Packages

Most Cisco MDS 9000 family software features are included in the standard package. However, some features are logically grouped into add-on packages that must be licensed separately, such as the Cisco MDS 9000 Enterprise package, SAN Extension over IP package, Mainframe package, Fabric Manager Server (FMS) package, Storage Services Enabler (SSE) package, Storage Media Encryption package, and Data Mobility Manager package. On-demand ports activation licenses are also available for the Cisco MDS Blade Switch Series and 4-Gbps Cisco MDS 9100 Series Multilayer Fabric switches.

Enterprise Package

The standard software package that is bundled at no charge with the Cisco MDS 9000 Family switches includes the base set of features that Cisco believes are required by most customers for building a SAN. The Cisco MDS 9000 family also has a set of advanced features that are recommended for all enterprise SANs. These features are bundled together in the Cisco MDS 9000 Enterprise package. Refer to the Cisco MDS 9000 Enterprise package fact sheet for more information.

SAN Extension over IP Package

The Cisco MDS 9000 SAN Extension over IP package allows the customer to use FCIP to extend SANs over wide distances on IP networks using the Cisco MDS 9000 family IP storage services. Refer to the Cisco MDS 9000 SAN Extension over IP package fact sheet for more information.

Mainframe Package

The Cisco MDS 9000 Mainframe package uses the FICON protocol and allows control unit port management for in-band management from IBM S/390 and z/900 processors. FICON VSAN support is provided to help ensure true hardware-based separation of FICON and open systems. Switch cascading, fabric binding, and intermixing are also included in this package. Refer to the Cisco MDS 9000 Mainframe package fact sheet for more information.

Storage Media Encryption Package

The Cisco MDS 9000 Storage Media Encryption package enables encryption of data at rest on heterogeneous tape devices and virtual tape libraries as a transparent fabric service. Cisco SME is completely integrated with Cisco MDS 9000 Family switches and the Cisco Fabric Manager application, enabling highly available encryption services to be deployed without rewiring or reconfiguring SANs, and allowing them to be managed easily without installing additional management software. Refer to the Cisco MDS 9000 Storage Media Encryption package fact sheet for more information. The Storage Media Encryption package is for use only with Cisco MDS 9000 Family switches.

Data Mobility Manager Package

The Cisco MDS 9000 Data Mobility Manager package enables data migration between heterogeneous disk arrays without introducing a virtualization layer or rewiring or reconfiguring SANs. Cisco DMM allows concurrent migration between multiple LUNs of unequal size. Rate-adjusted migration, data verification, dual Fibre Channel fabric support, and management using Cisco Fabric Manager provide a complete solution that greatly simplifies and eliminates most downtime associated with data migration. Refer to the Cisco MDS 9000 Data Mobility Manager package fact sheet for more information. The Data Mobility Manager package is for use only with Cisco MDS 9000 Family switches.

Storage Services Enabler Package

The Cisco MDS 9000 SSE package allows network-based storage applications and services to run on the Cisco MDS 9000 family SSMs, Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4), and Cisco MDS 9222i. Intelligent fabric applications simplify complex IT storage environments and help organizations gain control of capital and operating costs by providing consistent and automated storage management. Refer to the Cisco MDS 9000 SSE package fact sheet for more information.

On-Demand Port Activation License

On-demand ports allow customers to benefit from Cisco NX-OS Software features while initially purchasing only a small number of activated ports on 8-Gbps or 4-Gbps Cisco MDS 9100 Series Multilayer Fabric switches. As needed, customers can expand switch connectivity by licensing additional ports.

I/O Accelerator Package

The Cisco I/O Accelerator (IOA) package activates IOA on the Cisco MDS 9222i fabric switch, the Cisco MDS 9000 18/4 Multiservice Module (MSM-18/4), and on the SSN-16 module. The IOA package is licensed per service engine and is tied to the chassis. The number of licenses required is equal to the number of service engines on which the intelligent fabric application is used.The SSN-16 requires a separate license for each engine on which you want to run IOA. Each SSN-16 engine that you configure for IOA checks out a license from the pool managed at the chassis level. SSN-16 IOA licenses are available as single licenses.

XRC Acceleration License

The Cisco Extended Remote Copy (XRC) acceleration license activates FICON XRC acceleration on the Cisco MDS 9222i switch and on the MSM-18/4 in the Cisco MDS 9500 Series directors. One license per chassis is required. You must install the Mainframe Package and the SAN Extension over FCIP Package before you install the XRC acceleration license. The Mainframe Package enables the underlying FICON support, and the FCIP license or licenses enable the underlying FCIP support. XRC acceleration is not supported on the SSN-16.

Limitations and Restrictions

This section lists the limitations and restrictions for this release. The following limitations are described:

Support for Generation One Modules

IPv6

User Roles

Red Hat Enterprise Linux

Generation 1 Module Limitation

Schedule Job Configurations

Maximum Number of Zones Supported in Interop Mode 4

InterVSAN Routing

Java Web Start

VRRP Availability

Using a RSA Version 1 Key for SSH Following an Upgrade

CFS Cannot Distribute All Call Home Information

Availability of F Port Trunking and F Port Channels

Reserved VSAN Range and Isolated VSAN Range Guidelines

Applying Zone Configurations to VSAN 1

Running Storage Applications on the MSM-18/4

RSPAN Traffic Not Supported on CTS Ports on 8-Gbps Switching Modules

I/O Accelerator Feature Limitations

Support for FCIP Compression Modes

Saving Copies of the Running Kickstart and System Images

Configuring Buffer Credits on a Generation 2 or Generation 3 Module

Features Not Supported on the Cisco MDS 9148 Switch

PPRC Not Supported with FCIP Write Acceleration

Configuring a Persistent FCID in an IVR Configuration with Brocade Switches

Support for Generation One Modules

As of Cisco MDS NX-OS Release 5.0(1a), support for Generation One modules has been discontinued.

IPv6

The management port on Cisco MDS switches supports one user-configured IPv6 address, but does not support auto-configuration of an IPv6 address.

User Roles

In SAN-OS Release 3.3(x) and earlier, when a user belongs to a role which has a VSAN policy set to Deny and the role allows access to a specific set of VSANs (for example, 1 through 10), the user is restricted from performing the configuration, clear, execute, and debug commands which had a VSAN parameter outside this specified set. Beginning with NX-OS Release 4.1(1b), these users are still prevented from performing configuration, clear, execute, and debug commands as before, however, they are allowed to perform show commands for all VSANs. The ability to execute the show command addresses the following:

In a network environment, users often need to view information in other VSANs even though they do not have permission to modify configurations in those VSANs.

This behavior makes Cisco MDS 9000 Series switches consistent with other Cisco products, such as Cisco Nexus 7000 Series switches, that exhibit the same behavior for those roles (when they apply to the VLAN policy).

Red Hat Enterprise Linux

The Linux kernel core dump is not supported in NX-OS Release 4.1(1b) and later versions and therefore the CLI command has been removed. A syntax error message will be displayed if you import configurations from SAN-OS Release 3.3(x) and earlier to NX-OS Release 4.1(1b) and later. These syntax errors do not affect the application of other commands in the configuration and can be safely ignored. To address this, remove the kernel core configuration from the ASCII configuration file before importing the configuration.

Generation 1 Module Limitation

When a Cisco or other vendor switch port is connected to a Generation 1 module port (ISL connection), the receive buffer-to-buffer credit of the port connected to a Generation 1 module port should not exceed 255.

Schedule Job Configurations

As of MDS NX-OS Release 4.1(1b) and later, the scheduler job configurations need to be entered in a single line with a semicolon(;) as the delimiter.

Job configuration files created with SAN-OS Release 3.3(1c) and earlier, are not supported. However, you can edit the job configuration file and add the delimiter to support Cisco NX-OS Release 4.1(3a).

Maximum Number of Zones Supported in Interop Mode 4

In interop mode 4, the maximum number of zones that is supported in an active zone set is 2047, due to limitations in the connected vendor switch.

When IVR is used in interop mode 4, the maximum number of zones supported, including IVR zones, in the active zone set is 2047.

InterVSAN Routing

When using InterVSAN Routing (IVR), it is recommended to enable Cisco Fabric Services (CFS) on all IVR-enabled switches. Failure to do so may cause mismatched active zone sets if an error occurs during zone set activation.

Java Web Start

When using Java Web Start, it is recommended that you do not use an HTML cache or proxy server. You can use the Java Web Start Preferences panel to view or edit the proxy configuration. To do this, launch the Application Manager, either by clicking the desktop icon (Microsoft Windows), or type ./javaws in the Java Web Start installation directory (Solaris Operating Environment and Linux), and then select Edit> Preferences.

If you fail to change these settings, you may encounter installation issues regarding a version mismatch. If this occurs, you should clear your Java cache and retry.

VRRP Availability

The Virtual Router Redundancy Protocol (VRRP) is not available on the Gigabit Ethernet interfaces on the MSM-18/4 module or module 1 of the MDS 9222i switch, even though it is visible on these modules. The feature is not implemented in the current release.

Using a RSA Version 1 Key for SSH Following an Upgrade

For security reasons, NX-OS Release 4.2(1b) does not support RSA version 1 keys. As a result, if you upgrade to NX-OS Release 4.2(1b) from an earlier version that did support RSA version 1 keys, and you had configured a RSA version 1 key for SSH, then you will not be able to log in through SSH following the upgrade.

If you have a RSA version 1 key configured for SSH, before upgrading to NX-OS Release 4.1(3a), follow these steps:


Step 1 Disable SSH.

Step 2 Create RSA version 2 DSA keys.

Step 3 Enable SSH.

Step 4 Delete any RSA version 1 keys on any remote SSH clients and replace the version 1 keys with the new version 2 keys from the switch.

Proceed with the upgrade to NX-OS Release 4.2(1b).


If you upgrade before disabling SSH and creating RSA version 2 keys, follow these steps:


Step 1 Open a Telnet session and log in through the console.

Step 2 Issue the no feature ssh command to disable SSH.

Step 3 Issue the ssh key rsa 1024 command to create RSA version 2 keys.

Step 4 Issue the feature ssh command to enable SSH.


CFS Cannot Distribute All Call Home Information

In MDS NX-OS Release 4.2(1b), CFS cannot distribute the following Call Home commands that can be configured with the destination-profile command:

destination-profile profile_name transport-method

destination-profile profile_name http

The output of the show running-config callhome command shows configured Call Home commands:

switch# show running-config callhome
> version 4.1(3)
> callhome
>   email-contact abc@cisco.com <mailto:abc@cisco.com>
>   phone-contact +14087994089
>   streetaddress xyxxyx
>   distribute
>   destination-profile testProfile
>   destination-profile testProfile format XML
>   no destination-profile testProfile transport-method email
>   destination-profile testProfile transport-method http
>   destination-profile testProfile http https://xyz.abc.com
>   destination-profile testProfile alert-group all
>   transport email smtp-server 64.104.140.134 port 25 use-vrf management
>   transport email from abc@cisco.com <mailto:abc@cisco.com>
>   enable
>   commit 
 
   

When you attempt to apply these commands in the ASCII configuration, the following commands fail:

>   no destination-profile testProfile transport-method email
>   destination-profile testProfile transport-method http
>   destination-profile testProfile http https://xyz.abc.com
 
   

To work around this issue, issue these commands after the commit command.

Availability of F Port Trunking and F Port Channels

Trunking F ports and trunking F port channels are not supported on the following MDS 9000 components:

DS-C9134-K9, Cisco MDS 9134 Multilayer Fabric Switch, if NPIV is enabled and the switch is used as the NPV core switch

DS-C9124-K9, Cisco MDS 9124 Multilayer Fabric Switch, if NPIV is enabled and the switch is used as the NPV core switch

Trunking F ports, trunking F port channels and regular F port channels are not supported on the following MDS 9000 components:

DS-X9016, Cisco MDS 9000 2-Gbps16-Port Fibre Channel Switching Module

DS-X9032, Cisco MDS 9000 2-Gbps 32-Port Fibre Channel Switching Module

DS-X9032-14K9, Cisco MDS 9000 14/2-Port Multiprotocol Services Module (MPS-14/2)

For configuration information, refer to the "Configuring Trunking" section in the Cisco MDS 9000 NX-OS Interfaces Configuration Guide.

Reserved VSAN Range and Isolated VSAN Range Guidelines

On an NPV switch with a trunking configuration on any interface, or on a regular switch where the feature fport_channel_trunk command has been issued to enable the Trunking F PortChannels feature, follow these configuration guidelines for reserved VSANs and the isolated VSAN:

If trunk mode is on for any of the interfaces or NP PortChannel is up, the reserved VSANs are 3040 to 4078, and they are not available for user configuration.

The Exchange Virtual Fabric Protocol (EVFP) isolated VSAN is 4079, and it is not available for user configuration.

VSAN 4079 will be impacted by an upgrade to NX-OS Release 4.1(3a), depending on whether or not VSAN 4079 was created prior to the upgrade. See the "Upgrading Effect on VSAN 4079" section for details.

The following VSAN IDs are assigned in the Fibre Channel Framing and Signaling (FC-FS) interface standard:

VF_ID Value
Value Description

00h

Do not use as a Virtual Fabric Identifier.

001h ... EFFh

Available as a Virtual Fabric Identifier.

F00h ... FEEh

Reserved.

FEFh

Control VF-ID (see Fibre Channel Link Services (FC-LS) and Fibre Channel Switch Fabric Generation 4 (FC-SW-4) standards).

FF0h ... FFEh

Vendor specific.

FFFh

Do not use as a Virtual Fabric Identifier.

FEFh = 4079

 

Applying Zone Configurations to VSAN 1

In the setup script, you can configure system default values for the default-zone to be permit or deny, and you can configure default values for the zone distribution method and for the zone mode.

These default settings are applied when a new VSAN is created. However, the settings will not take effect on VSAN 1, because it exists prior to running the setup script. Therefore, when you need those settings for VSAN 1, you must explicitly issue the following commands:

zone default-zone permit vsan 1

zoneset distribute full vsan 1

zone mode enhanced vsan 1

Running Storage Applications on the MSM-18/4

The Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4) does not support multiple, concurrent storage applications. Only one application, such as SME or DMM, can run on the MSM-18/4 at a time.

RSPAN Traffic Not Supported on CTS Ports on 8-Gbps Switching Modules

An inter-switch link (ISL) that is enabled for Cisco TrustSec (CTS) encryption must be brought up in non-CTS mode to support remote SPAN (RSPAN) traffic on the following modules:

DS-X9248-96K9: Cisco MDS 9000 48-Port 8-Gbps Fibre Channel Switching Module

DS-X9224-96K9: Cisco MDS 9000 24-Port 8-Gbps Fibre Channel Switching Module

DS-X9248-48K9: Cisco MDS 9000 4/44-Port Host-Optimized 8-Gbps Fibre Channel Switching Module

If the ISL link is brought up with CTS enabled, random packets drops of both RSPAN traffic and normal traffic will occur on the receiver port switch.

I/O Accelerator Feature Limitations

IOA does not support the following NX-OS features:

F port trunking

F port channeling

IOA cannot be configured on flows in topologies that have devices with NPV and NPIV enabled. For example, IOA is not supported in a topology where a host logs in from a NPV edge switch and IOA is deployed on a NPV core switch for this host.

Support for FCIP Compression Modes

In Cisco NX-OS Release 4.2(1b) and later, FCIP compression mode 1 and compression mode 3 are not supported on the Cisco MSM-18/4 module and on the SSN-16 module.

Saving Copies of the Running Kickstart and System Images

After you upgrade to MDS NX-OS Release 4.2(1b), you are not allowed to delete, rename, move, or overwrite the kickstart and system images that are in the current system bootvar settings on an active or standby MDS Supervisor-2 module on any Cisco MDS 9500 Series switch. This restriction does not apply to the integrated supervisor module on the MDS 9200 and MDS 9100 series switches.

Configuring Buffer Credits on a Generation 2 or Generation 3 Module

When you configure port mode to auto or E on a Generation 2 module, one of the ports will not come up for the following configuration:

Port Mode: auto or E for all of the ports

Rate Mode: dedicated

Buffer Credits: default value

When you configure port mode to auto or E on a Generation 3 module, one or two of the ports will not come up for the following configuration:

Port Mode: auto or E for the first half of the ports, the second half of the ports, or for all of the ports

Rate Mode: dedicated

Buffer Credits: default value

When you configure port mode to auto or E for all ports in the global buffer pool, you need to reconfigure buffer credits on one or more of the ports. The total number of buffer credits configured for all the ports in the global buffer pool should be reduced by 64.

Features Not Supported on the Cisco MDS 9148 Switch

The Cisco MDS 9148 Multilayer Fabric Switch does not support the following NX-OS features:

IVR

Remote Span

Translative loop support

FCC - no generation, quench reaction only

FC-Redirect

In addition, the following features have these limits:

VSANs - 31 maximum

SPAN - 1 session maximum

PPRC Not Supported with FCIP Write Acceleration

IBM Peer to Peer Remote Copy (PPRC) is not supported with FCIP Write Acceleration.

Configuring a Persistent FCID in an IVR Configuration with Brocade Switches

The following information is relevant if you have a fabric that consists of Cisco MDS 9000 switches and Brocade switches, and the Cisco MDS switches are running either NX-OS Release 4.x or Release 5.x and Brocade is running FOS higher than 6.x. In an IVR configuration, when IVR NAT is enabled on a Cisco MDS 9000 switch, the device in the native VSAN should be configured with a persistent FCID. Assuming the FCID is 0xAABBCC, AA should be configured with the virtual IVR domain ID of the VSAN that contains the ISLs and BB should be configured in the following range:

1 through 64 if the Brocade switch is operating in native interop mode.

1 through 30 if the Brocade switch is operating in McData Fabric mode or McData Open Fabric Mode.

This configuration ensures that the devices connected to the Cisco MDS 9000 switch can be seen in the name server database on the Brocade switch.

Caveats

This section lists the open and resolved caveats for this release. Use Table 17 to determine the status of a particular caveat. In the table, "O" indicates an open caveat and "R" indicates a resolved caveat.

Table 17 Open Caveats and Resolved Caveats Reference 

DDTS Number
NX-OS Software Release (Open or Resolved)
NX-OS Software Release (Open or Resolved)
 
5.0(4b)
5.0(4c)

Severity 1

CSCto68011

O

O

Severity 2

CSCtf16263

O

O

CSCth80324

O

R

CSCti98457

O

R

CSCtl86272

O

R

CSCtn01631

O

R

CSCtn08556

O

R

CSCtn72391

O

O

CSCty32238

O

O

Severity 3

CSCsq20408

O

O

CSCte70856

O

R

CSCtl03553

O

R

CSCtn40775

O

R

CSCtl97673

O

R

CSCtn68831

O

R

Severity 4

CSCtk15939

O

R

CSCtn68418

O

O

CSCtn69150

O

R

Severity 6

CSCtk84348

O

R

CSCtn32076

O

R

CSCtn40097

O

R

CSCto05539

O

R


Resolved Caveats

CSCth80324

Symptom: FCIP links may flap due to maximum TCP retransmissions or because extended pings to a peer FCIP switch show packet loss. This issue affects all four Ethernet ports on the Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4) (DS-X9304-18K9) or on the MDS 9222i switch.

Workaround: This issue is resolved.

CSCti98457

Symptom: The Port Monitor triggers a BB credit not available event before 100 msec, even though the configured value for the event to get trigger is 100 ms.

Workaround: This issue is resolved.

CSCtl86272

Symptom: Following a software upgrade to Cisco NX-OS Release 4.2(7c) on an MDS 9222i switch, there is a traffic failure between newly configured flows, such regular zone flows, FC-redirect flows, IVR flows, and so on. The ACL TCAM entry for the affected flow has no adjacency pointer and therefore no forwarding information for the flow. This information can be seen as follows:

switch# attach mod x
switch# show process acltcam fwd-engine 0 input interface fcy/z
...
Loc  cl vsan  s_id   d_id si up sof   ipda dport prot sy fi fr en | pri mod ctl  adj 
up vld cw stats ce
--------------------------------------------------------------------------------------
-----------------
...
6ef6  2  64 7d0109 7d0101  1  0   0  0    0   0      0  0    0  0 |   0   0   0    0  
0   1  0     0  0
...

The error appears in the error-history file for the acltcam process:

switch# att mod x
switch# show process acltcam internal errors
...
128) Event:E_DEBUG, length:91, at 553029 usecs after Fri Jan 21 20:41:27 2011
    [107] acl_tcam_local_domain_list_init (3331):Unable to get local domains for 
existing vsans
...

Workaround: This issue is resolved.

CSCtn01631

Symptom: The Call Home process fails and then restarts when many RMON alerts are sent to Call Home.

Workaround: This issue is resolved.

CSCtn08556

Symptom: When you change a cluster node-description from Name to IP address, IOA fails.

Workaround: This issue is resolved.

CSCte70856

Symptom: The Cisco Call Home feature may stop sending Call Home alerts. In rare cases, the Call Home feature may become unconfigurable and may not be able to display information. In addition, you may not be able to save the configuration. The following syslog messages are displayed:

  %KERN-2-SYSTEM_MSG: mts_print_longest_queue_state: opcode counts for first and last 
50 messages in pers_q of sap 66: - kernel
  %KERN-2-SYSTEM_MSG: mts_print_msg_opcode_in_queue:  opcode 4853 - 100 messages - 
kernel
  %KERN-2-SYSTEM_MSG: mts_acquire_q_space() failing - no space in dst sap 66, uuid 63, 
src sap 28, opcode 4853 - kernel
 
   

This issue might be seen when the message level that is configured in Call Home is higher than the message level of the incoming alerts (such as from the RMON alerts from the Port Monitor feature).

Workaround: This issue is resolved.

CSCtl03553

Symptom: Following a system switchover, the slow drain port-monitor policy becomes active. This issue only occurs if no port-monitor policies are enabled for access ports.

Workaround: This issue is resolved.

CSCtn40775

Symptom: Tape devices that are managed by SME go offline. If you enter the show sme cluster roc_sme_cluster_01 it-nexus command, the following information is displayed:

-------------------------------------------------------------------------------
    Host WWN,              VSAN    Status    Switch        Interface
    Target WWN
-------------------------------------------------------------------------------
 
   
10:00:00:00:c9:38:88:a5,
50:05:07:63:00:4a:4a:01    50      online    rocmds01      sme5/1
 
   
10:00:00:00:c9:38:88:a5,
50:05:07:63:00:4a:4a:02    50      offline   --            --
 
   
Mon Feb 14 20:00:57 .4297]Program itl response failure code 0x3/0x5
Mon Feb 14 20:00:57 .4297]IT-NEXUS on sme13/1 vi-vt (21:25:00:0d:ec:6d:0b:42, 
21:21:00:0d:ec:6d:0b:42
Mon Feb 14 20:00:57 .4297]IT-NEXUS bind fail sme_mts_program_itl: error from cpp 0x3, 
0x5
 
   

Workaround: This issue is resolved.

CSCtl97673

Symptom: When the slow drain port-monitor policy is changed from its default configuration there is no corresponding line added to the running configuration or to the startup configuration. In addition, the slow drain policy activation configuration is lost after a switch reload.

Workaround: This issue is resolved.

CSCtn68831

Symptom: Upgrading from Cisco NX-OS Release 4.1(3a) to NX-OS Release 4.2(7d) fails because there is not enough memory in the buffer.

Workaround: This issue is resolved.

CSCtk15939

Symptom: The Call Home feature is not able to generate full-text message alerts. This symptom might be seen following an upgrade from SAN-OS Release 3.3(x).

Workaround: This issue is resolved.

CSCtn69150

Symptom: The install all command fails without a failure reason.

Workaround: This issue is resolved.

CSCtk84348

Symptom: In Cisco Release NX-OS 4.2(7a), the "credit loss recovery" and "TX credit not available" counters within the Port Monitor software log a human-readable interface-ID to syslog. All other Port Monitor counters do not log to syslog.

Workaround: This issue is resolved.

CSCtl03553

Symptom: Following a system switchover, the Slow Drain port-monitor policy becomes active. This issue only occurs if no port-monitor policies are enabled for access ports.

Workaround: This issue is resolved.

CSCtn32076

Symptom: The Call Home event triggers currently do not include the following message:

MODULE-4-MOD_WARNING 
 
   

Workaround: This issue is resolved.

CSCtn40097

Symptom: When a power supply fails, EMC and Cisco Call Home may not send alerts.

Workaround: This issue is resolved.

CSCto05539

Symptom: A supervisor module failed in a Cisco MDS 9500 Series switch because CRC errors that were receivied by the crossbar-interface ASIC in the supervisor module caused sync loss.

Workaround: This issue is resolved. The resolution is to differentiate CRC errors from actual hardware errors on the crossbar-interfaceASIC in the supervisor module.

Open Caveats

CSCto68011

Symptom: The fcdomain service on both supervisor modules fails, which results in a reload of the device. An error message similar to the following is displayed:

'' %SYSMGR-2-SERVICE_CRASHED: Service ''fcdomain'' (PID 4688) hasn't caught signal 11 
(core will be saved)'' 
 
   

This issue affects the following products when they have SNMP configured:

Cisco MDS 9000 Series Multilayer switches

Cisco Nexus 5000 Series switches and Cisco Nexus 2000 Series, running in FC switching mode (NPV mode is not affected).

The following products are confirmed not vulnerable:

Cisco Nexus 7000 Series switches

Cisco Nexus 4000 Series switches

Workaround: The following workaround is available:

Infrastructure Access Control Lists


Caution Because the feature in this vulnerability uses UDP as a transport, it is possible to spoof the sender's IP address, which may defeat ACLs that permit communication to these ports from trusted IP addresses.

Although it is often difficult to block traffic that transits a network, it is possible to identify traffic that should never be allowed to target infrastructure devices and block that traffic at the border of networks. Infrastructure Access Control Lists (iACLs) are a network security best practice and should be considered as a long-term addition to good network security as well as a workaround for this specific vulnerability. The iACL example below should be included as part of the deployed infrastructure access-list which will protect all devices with IP addresses in the infrastructure IP address range:

    !---
    !--- Feature: SNMP
    !---
    !--- 
    !--- Permit SNMP traffic from trusted sources. 
    !--- 
    ip access-list 150 permit udp TRUSTED_SOURCE_ADDRESSES WILDCARD 
        INFRASTRUCTURE_ADDRESSES WILDCARD eq port snmp
    ip access-list 150 permit tcp TRUSTED_SOURCE_ADDRESSES WILDCARD 
        INFRASTRUCTURE_ADDRESSES WILDCARD eq port snmp
    !--- 
    !--- Deny SNMP traffic from all other sources. 
    !--- 
    ip access-list 150 deny udp any any eq port snmp
    ip access-list 150 deny tcp any any eq port snmp
    !---
    !--- Permit/deny all other Layer 3 and Layer 4 traffic in 
    !--- accordance with existing security policies and 
    !--- configurations.  Permit all other traffic to transit the
    !--- device.
    !---
    access-list 150 permit ip any any
    !--- Apply access-list to management interface
    interface serial 2/0
     ip access-group 150 in
 
   

For more information on IP Access Control Lists see the "Configuring IPv4 and IPv6 Access Control List" section in the Cisco MDS 9000 Family NX-OS Security Configuration Guide at the following location:

http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/sec/nxos/ipacl.html

For more information on IP Access Control Lists see the "Configuring ACLs" section in the Cisco Nexus 5000 Series NX-OS Software Configuration Guide at the following location:

http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli_rel_4_0_1a/sec_ipacls.html

CSCtf16263

Symptom: Following an upgrade from Cisco MDS NX-OS Release 4.2(3a) to Release 5.0(1a) on an MDS 9222i switch, the Encapsulating Security Protocol (ESP) configuration is not applied to members of a PortChannel. This issue occurs only on the MDS 9222i switch.

Workaround: To workaround this issue, following these steps:

1. Enable Fibre Channel Security Protocol (FCSP) on the interface and enter configuration-interface-esp submode.

switch(config)# interface po103
switch(config-if)# fcsp on
switch(config-if)# fcsp esp manual
 
   

2. Add the old egress Security Association (egress-sa) configuration on the switch. Egress-sa is the other side of the active ingress-sa.

switch(config-if-esp)# egress-sa 258
 
   

3. Add a new ingress-sa on the switch. Do not use the previous SA.

switch(config-if-esp)# ingress-sa 256
 
   

4. On the other side of the PortChannel, reconfigure egress with 256.

switch(config)# interface po103
switch(config-if)# fcsp esp manual 
switch(config-if-esp)# egress-sa 256
 
   

At this point, the link is fully secured on both sides.

5. Clean up the old ingress-sa, by deleting it. An error message displays, but the ingress-sa does get deleted.

switch(config-if-esp)# no ingress-sa 258
ERROR: SA 258 not in ingress list
 
   

If you fail to delete the old ingress-sa, an error message displays:

 
   
switch(config-if-esp)# ingress-sa 258
ERROR: SA 258 already in ingress list
 
   

6. Add the old ingress-sa.

switch(config-if-esp)# ingress-sa 258
 
   

CSCtn72391

Symptom: Following a switch reload or a software upgrade, the startup configuration occasionally does not display feature fcip.

Workaround: Once the switch is completely up, copy the running configuration to the startup configuration by entering the copy running-config startup-config command.

CSCty32238

Symptom: On certain hardware, certain Cisco MDS 9000 Series features and applications do not work. These include IVR, IOA, DMM, SME, fcflow, and SPAN.

The following devices with hardware revision 1.5 are affected by this issue:

DS-X9248-96K9, 48-port 8-Gbps Fibre Channel Switching Module

DS-X9248-48K9, 4/44-port host-optimized 8-Gbps Fibre Channel Switching Module

DS-X9224-96K9, 24-port 8-Gbps Fibre Channel Switching Module

The following devices with hardware revision 1.0 are affected by this issue:

DS-X9304-18K9, 18/4-Port Multiservice Module (MSM-18/4)
For this module, the affected version is 73-14372-01A0 hardware version 1.0 (due to the new 73-number)

DS-C9222i-K9, Cisco MDS 9222i Multilayer Fabric Switch
For this switch, the affected version is 73-14373-01A0 hardware version 1.0 (due to the new 73-number)

For the DS-X9248-96K9, DS-X9248-48K9 and DS-X9224-96K9 modules, the output of the show module command indicates whether or not the device is affected.

switch# sh mod 2
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
2    24     1/2/4/8 Gbps FC Module              DS-X9224-96K9      ok
 
   
Mod  Sw              Hw      World-Wide-Name(s) (WWN)
---  --------------  ------  --------------------------------------------------
2    5.2(1)          <B>1.0</B>     20:41:00:0d:ec:24:f4:c0 to
20:58:00:0d:ec:24:f4:c0 
 
   

In the preceding output, the device is hardware revision 1.0 and therefore not affected.

For the DS-X9304-18K9 and the DS-C9222i-K9, the show module command might indicate hardware version 1.0 due to new part numbers; however the show sprom module command shows the affected parts.

switch# sh mod 9
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
9    22     4x1GE IPS, 18x1/2/4Gbps FC Module   DS-X9304-18K9      ok
 
   
Mod  Sw              Hw      World-Wide-Name(s) (WWN)
---  --------------  ------  --------------------------------------------------
9    5.2(1)          1.0     22:01:00:0d:ec:25:e9:80 to 22:12:00:0d:ec:25:e9:80 
 
   
Mod  MAC-Address(es)                         Serial-Num
---  --------------------------------------  ----------
9    00-1a-e2-03-4c-5c to 00-1a-e2-03-4c-64  JAE1131SCBW
 
   
switch# sh sprom module 9 1 |egrep "Part|Serial"
 Serial Number   : JAE1131SCBW
 Part Number     : 73-10688-06     <-- Not 73-14372-01 so h/w ver 1.0 is OK
 Part Revision   : A0

Workaround: Upgrade to software release that has the fix for this issue.

After performing a software upgrade to a Cisco NX-OS release that contains a fix for this issue, it may be necessary to enter the shut command followed by the no shut command on the affected host ports to regain connectivity.

If you perform a nondisruptive upgrade or downgrade from a release that contains a fix to a release that does not contain the fix, you need to reload each module affected by this issue.

If you have a Cisco MDS 9222i swtich that is affected by this issue, and you perform a nondisruptive upgrade or downgrade from a release that contains a fix to a release that does not contain the fix, you need to reload the switch.

CSCsq20408

Symptom: The show startup command displays aspects of the running configuration when SANTap is configured and/or SANTap objects are created. When a user creates objects such as a CVT or DVT, the configuration is showing in the running-configuration and in the startup-configuration without copying the configuration into the startup-configuration.

Workaround: Enter a copy running-config startup-config command whenever you create objects such as a CVT or DVT so that the running configuration and startup configuration are synchronized.

CSCtn68418

Symptom: When you try to save a configuration, you might see the following message:

switch# copy run start
[########################################] 100%
Configuration update aborted: request was aborted
 %DAEMON-3-SYSTEM_MSG: ntp:can't open /mnt/pss/ntp.drift.TEMP: No space left on device 
- ntpd[xxxx]
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR ALERT RECOVERED
 
   
`show system internal flash` output will display /isan as 100% full.
Mount-on                  1K-blocks      Used   Available   Use%  Filesystem
/                            204800     54624      150176     27   /dev/root
/proc                             0         0           0      0   proc
/isan                        409600    409576          24    100   none

This symptom was seen because the Call Home feature had duplicate message throttling disabled and there were flapping interfaces that generated thousands of Call Home messages. These messages filled up the ISAN directory.

Workaround: To work around this issue, enable Call Home duplicate message throttling. If you find that the /isan directory is 100 percent full, open a TAC case to get assistance with deleting the files.

Related Documentation

The documentation set for NX-OS for the Cisco MDS 9000 Family includes the following documents. To find a document online, access the following web site:

http://www.cisco.com/en/US/products/ps5989/tsd_products_support_series_home.html

The documentation set for Cisco Fabric Manager appears in the Cisco Fabric Manager Release Notes for Release 4.2(1), which is available from the following website:

http://www.cisco.com/en/US/products/ps10495/prod_release_notes_list.html

Release Notes

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases

Cisco MDS 9000 Family Release Notes for MDS SAN-OS Releases

Cisco MDS 9000 Family Release Notes for Storage Services Interface Images

Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images

Regulatory Compliance and Safety Information

Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family

Compatibility Information

Cisco Data Center Interoperability Support Matrix

Cisco MDS 9000 NX-OS Hardware and Software Compatibility Information and Feature Lists

Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images

Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

Cisco MDS NX-OS Release Compatibility Matrix for IBM SAN Volume Controller Software for Cisco MDS 9000

Cisco MDS SAN-OS Release Compatibility Matrix for VERITAS Storage Foundation for Networks Software

Hardware Installation

Cisco MDS 9500 Series Hardware Installation Guide

Cisco MDS 9500 Series Supervisor-2A Tech Note

Cisco MDS 9200 Series Hardware Installation Guide

Cisco MDS 9100 Series Hardware Installation Guide

Cisco MDS 9124 and Cisco MDS 9134 Multilayer Fabric Switch Quick Start Guide

Software Installation and Upgrade

Cisco MDS 9000 NX-OS Release 4.1(x) and SAN-OS 3(x) Software Upgrade and Downgrade Guide

Cisco MDS 9000 Family Storage Services Interface Image Install and Upgrade Guide

Cisco MDS 9000 Family Storage Services Module Software Installation and Upgrade Guide

Cisco NX-OS

Cisco MDS 9000 Family NX-OS Licensing Guide

Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide

Cisco MDS 9000 Family NX-OS System Management Configuration Guide

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

Cisco MDS 9000 Family NX-OS Fabric Configuration Guide

Cisco MDS 9000 Family NX-OS Quality of Service Configuration Guide

Cisco MDS 9000 Family NX-OS Security Configuration Guide

Cisco MDS 9000 Family NX-OS IP Services Configuration Guide

Cisco MDS 9000 Family NX-OS Intelligent Storage Services Configuration Guide

Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide

Cisco MDS 9000 Family NX-OS Inter-VSAN Routing Configuration Guide

Command-Line Interface

Cisco MDS 9000 Family Command Reference

Intelligent Storage Networking Services Configuration Guides

Cisco MDS 9000 I/O Acceleration Configuration Guide

Cisco MDS 9000 Family SANTap Deployment Guide

Cisco MDS 9000 Family Data Mobility Manager Configuration Guide

Cisco MDS 9000 Family Storage Media Encryption Configuration Guide

Cisco MDS 9000 Family Secure Erase Configuration Guide

Cisco MDS 9000 Family Cookbook for Cisco MDS SAN-OS

Troubleshooting and Reference

Cisco NX-OS System Messages Reference

Cisco MDS 9000 Family NX-OS Troubleshooting Guide

Cisco MDS 9000 Family NX-OS MIB Quick Reference

Cisco MDS 9000 Family NX-OS SMI-S Programming Reference

Obtaining Documentation and Submitting a Service Request

For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.