Table Of Contents
Device Manager System Requirements
Cisco Network Assistant Compatibility
Finding the Software Version and Feature Set
Upgrading a Switch by Using the Device Manager or Network Assistant
Upgrading a Switch by Using the CLI
Recovering from a Software Failure
Minimum Cisco IOS Release for Major Features
Cisco X2 Transceiver Modules and SFP Modules
Resolved Caveats in Cisco IOS Release 12.2(53)SE1
Resolved Caveats in Cisco IOS Release 12.2(53)SE
Updates to the Software Documentation
Update to the "Configuring IP Unicast Routing" Chapter
User Interface for VRF-Aware RADIUS
Update to the "Configuring IEEE 802.1x Port-Based Authentication" Chapter
Update to the "Configuring IEEE 802.1x Port-Based Authentication" Chapter
Update to the "Configuring Embedded Event Manager" Chapter
Updates to the Switch Getting Started Guide
Updates for the System Message Guide
Obtaining Documentation and Submitting a Service Request
Release Notes for the Cisco Catalyst Blade Switch 3130 and 3032 for Dell, Cisco IOS Release 12.2(53)SE and Later
March 16, 2010
Cisco IOS Release 12.2(53)SE and later runs on the Cisco Catalyst Blade Switch 3130 and 3032 for Dell switches. The Cisco Catalyst Blade Switch 3130 supports support stacking through Cisco StackWise Plus technology. Unless otherwise noted, the term switch refers to a standalone switch and to a switch stack.
Note The Cisco Catalyst Blade Switch 3032 does not support stacking.
These release notes include important information about Cisco IOS Release 12.2(53)SE and later and any limitations, restrictions, and caveats that apply to it. Verify that these release notes are correct for your switch:
•If you are installing a new switch, see the Cisco IOS release label on the rear panel of your switch.
•If your switch is on, use the show version privileged EXEC command. See the "Finding the Software Version and Feature Set" section.
•If you are upgrading to a new release, see the software upgrade filename for the software version. See the "Deciding Which Files to Use" section.
You can download the switch software from this site (registered Cisco.com users with a login password):
http://www.cisco.com/cisco/web/download/index.html
For the complete list of the Cisco Catalyst Blade Switch 3130 and 3032 for Dell documentation, see the "Related Documentation" section.
Contents
These sections provide information about this release:
•"System Requirements" section
•"Upgrading the Switch Software" section
•"Minimum Cisco IOS Release for Major Features" section
•"Limitations and Restrictions" section
•"Documentation Updates" section
•"Related Documentation" section
•"Obtaining Documentation and Submitting a Service Request" section
System Requirements
The system requirements are described in these sections:
•"Device Manager System Requirements" section
•"Cisco Network Assistant Compatibility" section
Hardware Supported
Table 1 lists the hardware supported on this release.
Table 1 Cisco Catalyst Blade Switch 3130 for Dell and 3032 for Dell Supported Hardware
Switch Hardware Description Supported by Minimum Cisco IOS ReleaseCBS3032G1 , CBS3130G-S, and CBS3130X-S
•16 internal Gigabit Ethernet 1000BASE-X downlink ports that connect to the 16 blade servers in the Dell chassis
•4 Gigabit Ethernet (RJ-45) uplink ports
•4 SFP module slots/2 10-Gigabit Ethernet X2 module slots2
•1 Ethernet management port (Fa0) used only for switch module management traffic
Cisco IOS Release 12.2(40)EX1
Cisco X2 transceiver modules
X2-10GB-SR
X2-10GB-LRM
X2-10GB-CX4X2-10GB-LR
X2-10GB-LX412.2(40)EX3
12.2(46)SE
SFP modules3
GLC-T
GLC-SX-MM
GLC-LH-SM12.2(40)EX3
Supports OneX (CVR-X2-SFP10G) and these SFP+ modules
(For the Catalyst Blade Switch 3130)
SFP-10G-SR
SFP-10G-LR
SFP-10G-LRMOnly version 02 or later CX14 cables are supported:
SFP-H10GB-CU1M
SFP-H10GB-CU3M
SFP-H10GB-CU5MCisco IOS Release 12.2(53)SE
1 This switch supports only the IP base software image.
2 X2 supported only on the CBS3130X-S model.
3 SFP = small form-factor pluggable
4 The CX1 cables are used with the OneX converters.
Caution The Cisco Catalyst Blade Switch 3130 for Dell does not support switch stacks with other types of blade switches as members. Combining the Cisco Catalyst Blade Switch 3130 for Dell with other types of blade switches in a switch stack might cause the switch to work improperly or to fail.
Device Manager System Requirements
These sections describe the hardware and software requirements for using the device manager:
•"Hardware Requirements" section
•"Software Requirements" section
Hardware Requirements
Table 2 lists the minimum hardware requirements for running the device manager.
Table 2 Minimum Hardware Requirements
Processor Speed DRAM Number of Colors Resolution Font Size233 MHz minimum1
512 MB2
256
1024 x 768
Small
1 We recommend 1 GHz.
2 We recommend 1-GB DRAM.
Software Requirements
These are the supported operating systems and browsers for the device manager:
•Windows 2000, XP, Vista, and Windows Server 2003.
•Internet Explorer 5.5, 6.0, 7.0, Firefox 1.5, 2.0 or later.
The device manager verifies the browser version when starting a session, and it does not require a plug-in.
Cisco Network Assistant Compatibility
Cisco IOS 12.2(40)EX1 and later is only compatible with Cisco Network Assistant 5.3 and later. You can download Network Assistant from this URL:
http://www.cisco.com/pcgi-bin/tablebuild.pl/NetworkAssistant
For more information about Cisco Network Assistant, see the Release Notes for Cisco Network Assistant on Cisco.com.
Upgrading the Switch Software
These are the procedures for downloading software. Before downloading software, read this section for important information:
•"Finding the Software Version and Feature Set" section
•"Deciding Which Files to Use" section
•"Upgrading a Switch by Using the Device Manager or Network Assistant" section
•"Upgrading a Switch by Using the CLI" section
•"Recovering from a Software Failure" section
Finding the Software Version and Feature Set
The Cisco IOS image is stored as a bin file in a directory that is named with the Cisco IOS release. A subdirectory contains the files needed for web management. The image is stored on the system board flash device (flash:).
You can use the show version privileged EXEC command to see the software version that is running on your switch. The second line of the display shows the version.
Note Although the show version output always shows the software image running on the switch, the model name shown at the end of this display is the factory configuration (IP base feature set or IP services feature set) and does not change if you upgrade the software license.
You can also use the dir filesystem: privileged EXEC command to see the directory names of other software images that you might have stored in flash memory.
Deciding Which Files to Use
The upgrade procedures in these release notes describe how to perform the upgrade by using a combined tar file. This file contains the Cisco IOS image file and the files needed for the embedded device manager. You must use the combined tar file to upgrade the switch through the device manager. To upgrade the switch through the command-line interface (CLI), use the tar file and the archive download-sw privileged EXEC command.
Table 3 lists the filenames for this software release.
Note To use the IPv6 routing and IPv6 ACL features on the Cisco Catalyst Blade Switch 3130 for Dell and 3032 for Dell, you must purchase the IP services software license from Cisco.
The universal software images support multiple feature sets. Use the software activation feature to deploy a software license and to enable a specific feature set. For information about software activation, see the Cisco Software Activation for Dell document on Cisco.com:
http://www.cisco.com/en/US/products/ps8742/products_installation_and_configuration_guides_list.html
Archiving Software Images
Before upgrading your switch software, make sure that you have archived copies of the current Cisco IOS release and the Cisco IOS release from which you are upgrading. You should keep these archived images until you have upgraded all devices in the network to the new Cisco IOS image and until you have verified that the new Cisco IOS image works properly in your network.
Cisco routinely removes old Cisco IOS versions from Cisco.com. See Product Bulletin 2863 for more information:
http://www.cisco.com/en/US/products/sw/iosswrel/ps5187/prod_bulletin0900aecd80281c0e.html
You can copy the bin software image file on the flash memory to the appropriate TFTP directory on a host by using the copy flash: tftp: privileged EXEC command.
Note Although you can copy any file on the flash memory to the TFTP server, it is time-consuming to copy all of the HTML files in the tar file. We recommend that you download the tar file from Cisco.com and archive it on an internal host in your network.
You can also configure the switch as a TFTP server to copy files from one switch to another without using an external TFTP server by using the tftp-server global configuration command. For more information about the tftp-server command, see the "Basic File Transfer Services Commands" section of the Cisco IOS Configuration Fundamentals Command Reference, Release 12.2, at this URL:
http://www.cisco.com/en/US/docs/ios/12_2/configfun/command/reference/ffun_r.html
Upgrading a Switch by Using the Device Manager or Network Assistant
You can upgrade switch software by using the device manager or Network Assistant. For detailed instructions, click Help.
Note When using the device manager to upgrade your switch, do not use or close your browser session after the upgrade process begins. Wait until after the upgrade process completes.
Upgrading a Switch by Using the CLI
This procedure is for copying the combined tar file to the switch. You copy the file to the switch from a TFTP server and extract the files. You can download an image file and replace or keep the current image.
To download software, follow these steps:
Step 1 Use Table 3 to identify the file that you want to download.
Step 2 Download the software image file. If you have a SmartNet support contract, go to this URL, and log in to download the appropriate files:
http://tools.cisco.com/support/downloads/pub/Redirect.x?mdfid=268438038
To download the universal software image files for a Cisco Catalyst Blade Switch 3130 for Dell or a Cisco Catalyst Blade Switch 3032 for Dell, click Blade Switches > Cisco Catalyst Blade Switch 3000 Series for Dell >. To obtain authorization and to download the cryptographic software files, click Cisco Catalyst Blade Switch 3000 Series for Dell Cryptographic Software.
Step 3 Copy the image to the appropriate TFTP directory on the workstation, and make sure that the TFTP server is properly configured.
For more information, see Appendix B in the software configuration guide for this release.
Step 4 Log into the switch through the console port or a Telnet session.
Step 5 (Optional) Ensure that you have IP connectivity to the TFTP server by entering this privileged EXEC command:
Switch# ping tftp-server-addressFor more information about assigning an IP address and default gateway to the switch, see the software configuration guide for this release.
Step 6 Download the image file from the TFTP server to the switch. If you are installing the same version of software that is currently on the switch, overwrite the current image by entering this privileged EXEC command:
Switch# archive download-sw /overwrite /reload tftp:[[//location]/directory]/image-name.tar
The /overwrite option overwrites the software image in flash memory with the downloaded one.
The /reload option reloads the system after downloading the image unless the configuration has been changed and not saved.
For //location, specify the IP address of the TFTP server.
For /directory/image-name.tar, specify the directory (optional) and the image to download. Directory and image names are case sensitive.
This example shows how to download an image from a TFTP server at 198.30.20.19 and to overwrite the image on the switch:
Switch# archive download-sw /overwrite tftp://198.30.20.19/image-name.tarYou can also download the image file from the TFTP server to the switch and keep the current image by replacing the /overwrite option with the /leave-old-sw option.
Recovering from a Software Failure
For additional recovery procedures, see the "Troubleshooting" chapter in the software configuration guide for this release.
Installation Notes
You can assign IP information to your switch by using these methods:
•The Express Setup program, as described in the switch getting started guide.
•The CLI-based setup program, as described in the switch hardware installation guide.
•The DHCP-based autoconfiguration, as described in the switch software configuration guide.
•Manually assigning an IP address, as described in the switch software configuration guide.
New Features
These sections describe the new supported hardware and the new and updated software features provided in this release:
•"New Hardware Features" section
•"New Software Feature" section
New Hardware Features
For a list of all supported hardware, see the "Hardware Supported" section.
New Software Feature
Support for the ip vrf forwarding vrf-name server-group configuration and the ip radius source-interface global configuration VRF-Aware RADIUS commands. For more information, see the "Updates to the Software Documentation" section.
Minimum Cisco IOS Release for Major Features
Table 4 lists the minimum software release (after the first release) required to support the major features of the Catalyst Blade Switch 3130 and 3032 for Dell. Features not listed are supported in all releases.
Limitations and Restrictions
You should review this section before you begin working with the switch. These are known limitations that will not be fixed, and there is not always a workaround. Some features might not work as documented, and some features could be affected by recent changes to the switch hardware or software.
This section contains these limitations:
•"Cisco IOS Limitations" section
•"Device Manager Limitations" section
Cisco IOS Limitations
These limitations apply to the Cisco Catalyst Blade Switch 3130and 3032 for Dell:
•"Access Control List" section
•"Address Resolution Protocol" section
•"Cisco X2 Transceiver Modules and SFP Modules" section
•"IEEE 802.1x Authentication" section
Access Control List
•The Cisco Catalyst Blade Switch 3130 and 3032 for Dell switches have 964 TCAM entries available for ACLs in the default and routing SDM templates instead of the 1024 entries that are available on the Catalyst 3560 and Catalyst 3750 switches.
There is no workaround. (CSCse33114)
•When a MAC access list is used to block packets from a specific source MAC address, that MAC address is entered in the switch MAC-address table.
The workaround is to block traffic from the specific MAC address by using the mac address-table static mac-addr vlan vlan-id drop global configuration command. (CSCse73823)
Address Resolution Protocol
•The switch might place a port in an error-disabled state due to an Address Resolution Protocol (ARP) rate limit exception even when the ARP traffic on the port is not exceeding the configured limit. This could happen when the burst interval setting is 1 second, the default.
The workaround is to set the burst interval to more than 1 second. We recommend setting the burst interval to 3 seconds even if you are not experiencing this problem.(CSCse06827))
Cisco X2 Transceiver Modules and SFP Modules
•Cisco X2-10GB-LR transceiver modules with a version identification number lower than V03 might show intermittent frame check sequence (FCS) errors or be ejected from the switch during periods of operational shock greater than 50g. There is no workaround. (CSCse14048)
•Cisco X2-10GB-CX4 transceiver modules with a version identification number lower than V03 might be difficult to insert because of a dimensional tolerance discrepancy. The workaround is to use modules with a version identification number of V03 or later. (CSCsg28558)
•Switches with the Cisco X2-10GB-LX4 transceiver modules with a version identification number prior to V03 might intermittently fail. The workaround is to use Cisco X2-10GB-LX4 transceiver modules with a version identification number of V03 or later. (CSCsh60076)
•When switches are installed closely together and the uplink ports of adjacent switches are in use, you might have problems accessing the SFP module bale-clasp latch to remove the SFP module or the SFP cable (Ethernet or fiber). Use one of these workarounds:
–Allow space between the switches when installing them.
–In a switch stack, plan the SFP module and cable installation so that uplinks in adjacent stack members are not all in use.
–Use long, small screwdriver to access the latch then remove the SFP module and cable. (CSCsd57938)
•When a Cisco X2-10GB-CX4 transceiver module is in the X2 transceiver module port and you enter the show controllers ethernet-controller tengigabitethernet privileged EXEC command, the command displays some fields as unspecified. This is the expected behavior based IEEE 802.3ae. (CSCsd47344)
•The far-end fault optional facility is not supported on the GLC-GE-100FX SFP module. The workaround is to configure aggressive UDLD. (CSCsh70244).
Configuration
•When an excessive number (more than 100 packets per second) of Address Resolution Protocol (ARP) packets are sent to a Network Admission Control (NAC) Layer 2 IP-configured member port, a switch might display a message similar to this:
PLATFORM_RPC-3-MSG_THROTTLED: RPC Msg Dropped by throttle mechanism: type 0, class 51, max_msg 128, total throttled 984323
-Traceback= 6625EC 5DB4C0 5DAA98 55CA80 A2F2E0 A268D8
No workaround is necessary. Under normal conditions, the switch generates this notification when snooping the next ARP packet. (CSCse47548)
•When there is a VLAN with protected ports configured in fallback bridge group, packets might not be forwarded between the protected ports.
The workaround is to not configure VLANs with protected ports as part of a fallback bridge group. (CSCsg40322)
When a switch port configuration is set at 10 Mb/s half duplex, sometimes the port does not send in one direction until the port traffic is stopped and then restarted. You can detect the condition by using the show controller ethernet-controller or the show interfaces privileged EXEC commands.
The workaround is to stop the traffic in the direction in which it is not being forwarded, and then restart it after 2 seconds. You can also use the shutdown interface configuration command followed by the no shutdown command on the interface. (CSCsh04301)
•When line rate traffic is passing through a dynamic port, and you enter the switchport access vlan dynamic interface configuration command for a range of ports, the VLANs might not be assigned correctly. One or more VLANs with a null ID appears in the MAC address table instead.
The workaround is to enter the switchport access vlan dynamic interface configuration command separately on each port.(CSCsi26392)
•If a half-duplex port running at 10 Mb/s receives frames with Inter-Packet Gap (IPG) that do not conform to Ethernet specifications, the switch might stop sending packets.
There is no workaround. (CSCec74610)
EtherChannel
•In an EtherChannel running Link Aggregation Control Protocol (LACP), the ports might be put in the suspended or error-disabled state after a stack partitions or a member switch reloads. This occurs when
–The EtherChannel is a cross-stack EtherChannel with a switch stack at one or both ends.
–The switch stack partitions because a member reloads. The EtherChannel is divided between the two partitioned stacks, each with a stack master.
The EtherChannel ports are put in the suspended state because each partitioned stack sends LACP packets with different LACP Link Aggregation IDs (the system IDs are different). The ports that receive the packets detect the incompatibility and shut down some of the ports. Use one of these workarounds for ports in this error-disabled state:
–Enable the switch to recover from the error-disabled state.
–Enter the shutdown and the no shutdown interface configuration commands to enable the port.
The EtherChannel ports are put in the error-disabled state because the switches in the partitioned stacks send STP BPDUs. The switch or stack at the other end of the EtherChannel receiving the multiple BPDUs with different source MAC addresses detects an EtherChannel misconfiguration.
After the partitioned stacks merge, ports in the suspended state should automatically recover. (CSCse33842)
•When a switch stack is configured with a cross-stack EtherChannel, it might transmit duplicate packets across the EtherChannel when a physical port in the EtherChannel has a link-up or link-down event. This can occur for a few milliseconds while the switch stack adjusts the EtherChannel for the new set of active physical ports and can happen when the cross-stack EtherChannel is configured with either mode ON or LACP. This problem might not occur with all link-up or link-down events.
No workaround is necessary. The problem corrects itself after the link-up or link-down event. (CSCse75508)
•The switch might display tracebacks similar to this example when an EtherChannel interface port-channel type changes from Layer 2 to Layer 3 or the reverse:
15:50:11: %COMMON_FIB-4-FIBNULLHWIDB: Missing hwidb for fibhwidb Port-channel1 (ifindex 1632) -Traceback= A585C B881B8 B891CC 2F4F70 5550E8 564EAC 851338 84AF0C 4CEB50 859DF4 A7BF28 A98260 882658 879A58
There is no workaround. (CSCsh12472)
IEEE 802.1x Authentication
•If a supplicant using a Marvel Yukon network interface card (NIC) is connected an IEEE 802.1x-authorized port in multihost mode, the extra MAC address of 0c00.0000.0000 appears in the MAC address table.
Use one of these workarounds (CSCsd90495):
–Configure the port for single-host mode to prevent the extra MAC address from appearing in the MAC address table.
–Replace the NIC card with a new card.
•When MAC authentication bypass is configured to use Extensible Authentication Protocol (EAP) for authorization and critical authentication is configured to assign a critical port to an access VLAN:
–If the connected device is supposed to be unauthorized, the connected device might be authorized on the VLAN that is assigned to the critical port instead of to a guest VLAN.
–If the device is supposed to be authorized, it is authorized on the VLAN that is assigned to the critical port.
Use one of these workarounds (CSCse04534):
–Configure MAC authentication bypass to not use EAP.
–Define your network access profiles to not use MAC authentication bypass. For more information, see the Cisco Access Control Server (ACS) documentation.
•When IEEE 802.1x authentication with VLAN assignment is enabled, a CPUHOG message might appear if the switch is authenticating supplicants in a switch stack.
The workaround is not use the VLAN assignment option. (CSCse22791)
Multicasting
•Multicast packets with a time-to-live (TTL) value of 0 or 1 are flooded in the incoming VLAN when all of these conditions are met:
–Multicast routing is enabled in the VLAN.
–The source IP address of the packet belongs to the directly connected network.
–The TTL value is either 0 or 1.
The workaround is to not generate multicast packets with a TTL value of 0 or 1, or disable multicast routing in the VLAN. (CSCeh21660)
•Multicast packets denied by the multicast boundary access list are flooded in the incoming VLAN when all of these conditions are met:
–Multicast routing is enabled in the VLAN.
–The source IP address of the multicast packet belongs to a directly connected network.
–The packet is denied by the IP multicast boundary access-list configured on the VLAN.
There is no workaround. (CSCei08359)
•Reverse path forwarding (RPF) failed multicast traffic might cause a flood of Protocol Independent Multicast (PIM) messages in the VLAN when a packet source IP address is not reachable.
The workaround is to not send RPF-failed multicast traffic, or make sure that the source IP address of the RPF-failed packet is reachable. (CSCsd28944)
•If the clear ip mroute privileged EXEC command is used when multicast packets are present, it might cause temporary flooding of incoming multicast traffic in the VLAN.
There is no workaround. (CSCsd45753)
•When you configure the ip igmp max-groups number and ip igmp max-groups action replace interface configuration commands and the number of reports exceed the configured max-groups value, the number of groups might temporarily exceed the configured max-groups value. No workaround is necessary because the problem corrects itself when the rate or number of IGMP reports are reduced. (CSCse27757)
•When you configure the IGMP snooping throttle limit by using the ip igmp max-groups number interface configuration on a port-channel interface, the groups learned on the port-channel might exceed the configured throttle limit number, when all of these conditions are true:
–The port-channel is configured with member ports across different switches in the stack.
–When one of the member switches reloads.
–The member switch that is reloading has a high rate of IP IGMP joins arriving on the port-channel member port.
The workaround is to disable the IGMP snooping throttle limit by using the no ip igmp max-groups number interface configuration command and then to reconfigure the same limit again. (CSCse39909)
QoS
•When QoS is enabled and the egress port receives pause frames at the line rate, the port cannot send packets.
There is no workaround. (CSCeh18677)
•Egress shaped round robin (SRR) sharing weights do not work properly with system jumbo MTU frames.
There is no workaround. (CSCsc63334)
•In a hierarchical policy map, if the VLAN-level policy map is attached to a VLAN interface and the name of the interface-level policy map is the same as that for another VLAN-level policy map, the switch rejects the configuration, and the VLAN-level policy map is removed from the interface.
The workaround is to use a different name for the interface-level policy map. (CSCsd84001)
•If the ingress queue has low buffer settings and the switch sends multiple data streams of system jumbo MTU frames at the same time at the line rate, the frames are dropped at the ingress.
There is no workaround. (CSCsd72001)
•When you use the srr-queue bandwidth limit interface configuration command to limit port bandwidth, packets that are less than 256 bytes can cause inaccurate port bandwidth readings. The accuracy is improved when the packet size is greater than 512 bytes. There is no workaround. (CSCsg79627)
•If QoS is enabled on a switch and the switch has a high volume of incoming packets with a maximum transmission unit (MTU) size greater than 1512 bytes, the switch might reload.
Use one of these workarounds:
– Use the default buffer size.
– Use the mls qos queue-set output qset-id buffers allocation1 ... allocation4 global configuration command to allocate the buffer size. The buffer space for each queue must be at least 10 percent. (CSCsx69718)
RADIUS
RADIUS change of authorization (COA) reauthorization is not supported on the critical auth VLAN.
There is no workaround. (CSCta05071)
Routing
•The switch stack might reload if the switch runs with this configuration for several hours, depleting the switch memory and causing the switch to fail:
–The switch has 400 Open Shortest Path First (OSPF) neighbors.
–The switch has thousands of OSPF routes.
The workaround is to reduce the number of OSPF neighbors to 200 or less. (CSCse65252)
•When the PBR is enabled and QoS is enabled with DSCP settings, the CPU utilization might be high if traffic is sent to unknown destinations.
The workaround is to not send traffic to unknown destinations. (CSCse97660)
SPAN and RSPAN
•When egress SPAN is running on a 10-Gigabit Ethernet port, only about 12 percent of the egress traffic is monitored.
There is no workaround. This is a hardware limitation. (CSCei10129)
•When the logging event-spanning-tree interface configuration command is configured and logging to the console is enabled, a topology change might generate a large number of logging messages, causing high CPU utilization. CPU utilization can increase with the number of spanning-tree instances and the number of interfaces configured with the logging event-spanning-tree interface configuration command. This condition adversely affects how the switch operates and could cause problems such as STP convergence delay.
High CPU utilization can also occur with other conditions, such as when debug messages are logged at a high rate to the console.
Use one of these workarounds (CSCsg91027):
–Disable logging to the console.
–Rate-limit logging messages to the console.
–Remove the logging event spanning-tree interface configuration command from the interfaces.
•The far-end fault optional facility is not supported on the GLC-GE-100FX SFP module.
The workaround is to configure aggressive UDLD. (CSCsh70244).
VLANs
•When the domain is authorized in the guest VLAN on a member switch port without link loss and an Extensible Authentication Protocol over LAN (EAPOL) is sent to an IEEE 802.1x supplicant to authenticate, the authentication fails. This problem happens intermittently with certain stacking configurations and only occurs on the member switches.
The workaround is to enter the shutdown and no shutdown interface configuration commands on the port to reset the authentication status. (CSCsf98557)
Stacking
•When using the logging console global configuration command, low-level messages appear on both the stack master and the stack member consoles.
The workaround is to use the logging monitor global configuration command to set the severity level to block the low-level messages on the stack member consoles. (CSCsd79037)
•If a new member switch joins a switch stack within 30 seconds of a command to copy the switch configuration to the running configuration of the stack master, the new member might not get the latest running configuration and might not operate properly.
The workaround is to reboot the new member switch. Use the remote command all show run privileged EXEC command to compare the running configurations of the stack members. (CSCsf31301)
•When the flash memory of a stack member is almost full, it might take longer to start up than other member switches. This might cause that switch to miss the stack-master election window. As a result, the switch might fail to become the stack master even though it has the highest priority.
The workaround is to delete files in the flash memory to create more free space. (CSCsg30073)
•The error message %DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND might appear for a switch stack under these conditions:
–IEEE 802.1 is enabled.
–A supplicant is authenticated on at least one port.
–A new member joins a switch stack.
You can use one of these workarounds:
–Enter the shutdown and the no shutdown interface configuration commands to reset the port.
–Remove and reconfigure the VLAN. (CSCsi26444)
•When you use the switch renumber global configuration command to renumber a member switch in a switch stack and then reload the switch, the internal server-facing ports do not have the required default of spanning-tree portfast enabled.
The workaround is to apply the switch provision configuration before you reboot the switch. Enter both the switch current-stack-member-number renumber new-stack-member-number and the switch stack-member-number provision type global configuration commands, and reload the switch. (CSCsl63862)
•If you enter the show tech-support privileged EXEC command after you enter the remote command {all | stack-member-number} privileged EXEC command, the complete output does not appear.
The workaround is to use the session stack-member-number privileged EXEC command. (CSCsz38090)
Device Manager Limitations
•When you are prompted to accept the security certificate and you click No, you only see a blank screen, and the device manager does not launch.
The workaround is to click Yes when you are prompted to accept the certificate. (CSCef45718)
•If you launch the device manager from a Firefox web browser, an invalid certificate alert appears. If you launch the device manager from an Internet Explorer 7.0 browser, a certificate error appears.
The workaround when using Firefox is to either temporarily or permanently accept the certificate. If you temporarily accept the certificate, close and then reopen the Firefox browser window. If you permanently accept the certificate, delete the certificate, then close and restart Firefox:
–If you are using Firefox version 1.5, choose Tools > Options > Advanced > Security > View Certificates > Web Sites, select the certificate and click Delete.
–If you are using Firefox version 2.0, choose Tools > Options > Advanced > Encryption > View Certificates > Web Sites, select the certificate and click Delete.
The workaround when using Internet Explorer is to click Click here for Options in the warning message and click Display Blocked Content. Close the browser window and launch a new session. (CSCsk80229)
Important Notes
These sections describe the important notes related to this software release:
•"Device Manager Notes" section
Cisco IOS Notes
These notes apply to Cisco IOS software:
•If the switch requests information from the Cisco Secure Access Control Server (ACS) and the message exchange times out because the server does not respond, a message similar to this appears:
00:02:57: %RADIUS-4-RADIUS_DEAD: RADIUS server 172.20.246.206:1645,1646 is not responding.If this message appears, make sure that there is network connectivity between the switch and the ACS. You should also make sure that the switch has been properly configured as an AAA client on the ACS.
•If the switch has interfaces with automatic QoS for voice over IP (VoIP) configured and you upgrade the switch software to Cisco IOS Release 12.2(40)EX1 (or later), when you enter the auto qos voip cisco-phone interface configuration command on another interface, you might see this message:
AutoQoS Error: ciscophone input service policy was not properly appliedpolicy map AutoQoS-Police-CiscoPhone not configuredIf this happens, enter the no auto qos voip cisco-phone interface command on all interface with this configuration to delete it. Then enter the auto qos voip cisco-phone command on each of these interfaces to reapply the configuration.
Device Manager Notes
These notes apply to the device manager:
•You cannot create and manage switch clusters through the device manager. To create and manage switch clusters, use the CLI or Cisco Network Assistant.
•When the switch is running a localized version of the device manager, the switch displays settings and status only in English letters. Input entries on the switch can only be in English letters.
•For device manager session on Internet Explorer, popup messages in Japanese or in simplified Chinese can appear as garbled text. These messages appear properly if your operating system is in Japanese or Chinese.
•We recommend this browser setting to speed up the time needed to display the device manager from Microsoft Internet Explorer.
From Microsoft Internet Explorer:
1. Choose Tools > Internet Options.
2. Click Settings in the "Temporary Internet files" area.
3. From the Settings window, choose Automatically.
4. Click OK.
5. Click OK to exit the Internet Options window.
•The HTTP server interface must be enabled to display the device manager. By default, the HTTP server is enabled on the switch. Use the show running-config privileged EXEC command to see if the HTTP server is enabled or disabled.
Beginning in privileged EXEC mode, follow these steps to configure the HTTP server interface:
•The device manager uses the HTTP protocol (the default is port 80) and the default method of authentication (the enable password) to communicate with the switch through any of its Ethernet ports and to allow switch management from a standard web browser.
If you change the HTTP port, you must include the new port number when you enter the IP address in the browser Location or Address field (for example, http://10.1.126.45:184 where 184 is the new HTTP port number). You should write down the port number through which you are connected. Use care when changing the switch IP information.
If you are not using the default method of authentication (the enable password), you need to configure the HTTP server interface with the method of authentication used on the switch.
Beginning in privileged EXEC mode, follow these steps to configure the HTTP server interface:
If you use Internet Explorer Version 5.5 and select a URL with a nonstandard port at the end of the address (for example, www.cisco.com:84), you must enter http:// as the URL prefix. Otherwise, you cannot launch the device manager.
Open Caveats
•CSCsy85676
When you configure an ACL and enter the access-group interface configuration command to apply it to an interface for web authentication, the output from the show epm session ip-address or show ip access_list interface interface-id privileged EXEC command does not show any web authentication filter ID.
There is no workaround.
•CSCsz18634
On a switch running Cisco IOS release 12.2(46)SE, the output of the show interfaces privileged EXEC command shows 0 packets for port channel input and output rates.
The workaround is to reload the switch by entering the reload privileged EXEC command.
•CSCta72141
The bootloader label is incorrect and displays "CISCO DEVELOPMENT TEST VERSION." However, the actual bootloader software is the correct version with the correct functionality.
There is no workaround. It does not impact functionality.
•CSCtb08823
SNMP requests on the stpxRSTPPortRoleTable object only return information for the stack master.
There is no workaround.
•CSCtb25230
When a switch stack is configured with DHCP snooping enabled on the host VLAN, hosts connected to the stack master receive bootp packets, but the a packet might not be forwarded to the end hosts connected to stack member switches. The behavior depends on which interface in the stack received the packet.
The workaround is to disable DHCP snooping for the affected VLAN.
•CSCtc02635
On switches running Cisco IOS release 12.2(50)SE3 running MAC authentication bypass with multidomain authentication (MDA, IP phones connected to a port might not be able to regain network connectivity in the VOICE domain if the session times out and all RADIUS servers are unreachable.
There is no workaround.
•CSCtd29049
A switch that has at least one trunk port configured might fail when you configure more than 950 VLANS by using the vlan vlan-id global configuration command.
There is no workaround.
Resolved Caveats
•Resolved Caveats in Cisco IOS Release 12.2(53)SE1
•Resolved Caveats in Cisco IOS Release 12.2(53)SE
Resolved Caveats in Cisco IOS Release 12.2(53)SE1
•CSCsx97605
The CISCO-RTTMON-MIB is not correctly implemented in this release.
•CSCtb10158
A switch can fail when an SNMP process attempts to configure dot1x authentication when it is already configured.
There is no workaround.
•CSCtc43231
A switch does not receive SNMP trap and inform messages from the correct interface after you have entered the snmp-server trap-source loopback0 and snmp-server source-interface informs loopback0 global configuration commands.
There is no workaround.
•CSCte52821
When you enter the no ip ftp passive global configuration command to allow all types of FTP connections on a switch running Cisco IOS Release 12.2(52)SE or 12.2(53)SE, FTP sessions could disable Telnet or console connections. Then you can no longer use the vty.
Workaround: When you cannot use the vty, restart the switch. To prevent FTP sessions from disabling Telnet or console connections, enter the ip ftp passive global configuration command.
•CSCtc59162
Modifying a prefix list that is configured as an inbound or outbound distribute-list causes the EIGRP peer to resynchronize.
•CSCtc71798
Traffic received on a member interface of a cross-stack EtherChannel is dropped from a switch stack. This intermittently occurred in previous releases after a stack reloaded.
•CSCte67201
On a switch that is configured for IP routing and that is running Cisco IOS Release 12.2(50)SE or later, Cisco Express Forwarding (CEF) can use a large amount of memory. The IP RIB Update process uses about 2000 bytes for each prefix that CEF uses.
There is no workaround. You can reduce the memory use by reducing the number of routes the switch processes.
•CSCte72365
After upgrading from Cisco IOS 12.2(52)SE to Cisco IOS 12.2(53)SE, EIGRP hello packets are flooded on access ports of other subnets. This also occurs when pings are sent to the broadcast address of other subnets.
Resolved Caveats in Cisco IOS Release 12.2(53)SE
•CSCsj68446
The Network Time Protocol (NTP) might not synchronize when the switch is configured as an NTP client. These are the two possible workarounds:
–Enter the no ntp global configuration command twice.
–Reconfigure NTP on the port. For more information, see the "Configuring NTP" section of the "Administering the Switch" chapter in the software configuration guide.
•CSCsv92937
When a blade server starts, the switch internal interface might flap due to the network interface card (NIC) driver. In Cisco IOS Release 12.2(46)SE and earlier, the port might enter the error-disabled state.
The workaround is to enter the errdisable max flap 10 time 10 global configuration command in Cisco IOS Release 12.2(46)SE and earlier. In Cisco IOS Release 12.2(50)SE and later, the switch no longer detects link flapping on the internal interfaces.
•CSCsx29696
On a switch running Cisco IOS Release 12.2(35)SE or later, connectivity issues might occur with these messages:
%SUPQ-4-CPUHB_RECV_STARVE: Still seeing receive queue stuck after throttling•CSCsy14568
When a switch port rejoins a cross-stack EtherChannel after the switch restarts, packets might be dropped for a longer than expected time.
There is no workaround.
•CSCsz18634
On a switch running Cisco IOS release 12.2(46)SE, the output of the show interfaces privileged EXEC command shows 0 packets for port channel input and output rates.
The workaround is to reload the switch by entering the reload privileged EXEC command.
•CSCtc02635
On switches running Cisco IOS Release 12.2(50)SE3 running MAC authentication bypass with multidomain authentication (MDA), IP phones connected to a port might not be able to regain network connectivity in the VOICE domain if the session times out and all RADIUS servers are unreachable.
There is no workaround.
•CSCtc16848
The output of the show inventory user EXEC command sometimes does not display all of the connected SFP modules. The EntitityMIB does not report these SFP modules.
This occurs intermittently on the 3560-48TS, C3560-48PS, and C3560G-48PS switches. There is no workaround.
•CSCtc20603
If IEEE 802.1Q native VLAN tagging is enabled on a switch, PDUs sent from an EtherChannel in LACP mode are tagged.
There is no workaround.
•CSCtc30872
When a BPDU guard is globally enabled on a switch and the access VLAN is a VLAN other than VLAN 1, BPDU guard does not run on a multiple VLAN access port.
The workaround is to enable BPDU guard on the port.
•CSCtc57809
When the no mac address-table static mac-addr vlan vlan-id interface interface-id global configuration command is used to remove a dynamically learned MAC address, the switch fails under these conditions:
–The physical interface is in a no shutdown state.
–The MAC address is first dynamically learned and then changed to static.
There is no workaround.
•CSCtd31242
An IP phone loses network connectivity under these conditions:
–The IP phone is authenticated by MAB (in Open1x mode) on a supplicant switch.
–The supplicant switch is connected to an authenticator switch through the NEAT protocol.
–A call is placed using the IP phone. After approximately 5 minutes, network connectivity to the phone is lost.
The workaround is to statically configure the MAC address of the IP phone on the authenticator switch.
•CSCtd72456
After you have entered the snmp-server host informs global configuration command to enable SNMP informs on a switch, the switch might fail if you enter the show snmp pending user EXEC command.
There is no workaround. Do not enter the show command when SNMP informs are enabled.
Documentation Updates
•Updates to the Software Documentation
•Updates to the Switch Getting Started Guide
•Updates for the System Message Guide
Updates to the Software Documentation
Update to the "Configuring IP Unicast Routing" Chapter
This section was added to the "Configuring IP Unicast Routing" chapter:
User Interface for VRF-Aware RADIUS
To configure VRF-Aware RADIUS, you must first enable AAA on a RADIUS server. This release supports the ip vrf forwarding vrf-name server-group configuration and the ip radius source-interface global configuration commands, as described in the Per VRF AAA Feature Guide at this URL:
http://www.cisco.com/en/US/docs/ios/12_2t/12_2t13/feature/guide/ftvrfaaa.html
The switch does not support ISL trunking.
Update to the "Configuring IEEE 802.1x Port-Based Authentication" Chapter
Common Session ID
Authentication manager uses a single session ID (referred to as a common session ID) for a client no matter which authentication method is used. This ID is used for all reporting purposes, such as the show commands and MIBs. The session ID appears with all per-session syslog messages.
The session ID includes:
•The IP address of the Network Access Device (NAD)
•A monotonically increasing unique 32 bit integer
•The session start time stamp (a 32 bit integer)
This example shows how the session ID appears in the output of the show authentication command. The session ID in this example is 160000050000000B288508E5:
Switch# show authentication sessions
Interface MAC Address Method Domain Status Session IDFa4/0/4 0000.0000.0203 mab DATA Authz Success 160000050000000B288508E5This is an example of how the session ID appears in the syslog output. The session ID in this example is also160000050000000B288508E5:
1w0d: %AUTHMGR-5-START: Starting 'mab' for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E51w0d: %MAB-5-SUCCESS: Authentication successful for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E51w0d: %AUTHMGR-7-RESULT: Authentication result 'success' from 'mab' for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E5The session ID is used by the NAD, the AAA server, and other report-analyzing applications to identify the client. The ID appears automatically. No configuration is required.
Update to the "Configuring IEEE 802.1x Port-Based Authentication" Chapter
This guideline was added to the "802.1x Authentication" section of the "Configuring IEEE 802.1x Port-Based Authentication" chapter.
•When IP phones are connected to an 802.1x-enabled switch port that is in single host mode, the switch grants the phones network access without authenticating them. We recommend that you use multidomain authentication (MDA) on the port to authenticate both a data device and a voice device, such as an IP phone.
Update to the "Configuring Embedded Event Manager" Chapter
Embedded Event Manager 3.2
Embedded Event Manager (EEM) is a distributed and customized approach to event detection and recovery offered directly in a Cisco IOS device. EEM offers the ability to monitor events and take informational, corrective, or any desired EEM action when the monitored events occur or when a threshold is reached. An EEM policy is an entity that defines an event and the actions to be taken when that event occurs.
EEM 3.2 is supported in Cisco IOS Release 12.2(52)SE and later releases, and introduced many new features.
EEM 3.2 introduces the following new event detectors:
•Neighbor Discovery—Neighbor Discovery event detector provides the ability to publish a policy to respond to automatic neighbor detection when:
–a Cisco Discovery Protocol (CDP) cache entry is added, deleted, or updated.
–a Link Layer Discovery Protocol (LLDP) cache entry is added, deleted, or updated.
–an interface link status changes.
–an interface line status changes.
•Identity—Identity event detector generates an event when AAA authorization and authentication is successful, when failure occurs, or after normal user traffic on the port is allowed to flow.
•Mac-Address-Table—Mac-Address-Table event detector generates an event when a MAC address is learned in the MAC address table.
Note The Mac-Address-Table event detector is supported only on switch platforms and can be used only on Layer 2 interfaces where MAC addresses are learned. Layer 3 interfaces do not learn addresses and routers do not usually support the mac-address-table infrastructure needed to notify EEM of a learned MAC address.
EEM 3.2 also introduces new CLI commands to support the applets to work with the new event detectors.
For further details about EEM 3.2 features, see the Embedded Event Manager 3.2 document.
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_3.2.html
For the complete EEM document set, see these documents:
•Embedded Event Manager Overview
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_overview.html
•Writing Embedded Event Manager Policies Using the Cisco IOS CLI
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_policy_cli.html
•Writing Embedded Event Manager Policies Using Tcl
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_policy_tcl.html
Update to the "MSTP" Chapter
This guideline was added to the "MSTP Configuration Guidelines" section of the "Configuring MSTP" chapter:
•When the switch is in MST mode, it uses the long path-cost calculation method (32 bits) to compute the path cost values. With the long path-cost calculation method, these path cost values are supported:
Updates to the Switch Getting Started Guide
When you launch Express Setup, you are prompted for the switch password. Enter the default password, cisco. The switch ignores text in the username field. Before you complete and exit Express Setup, you must change the password from the default password, cisco.
Updates for the System Message Guide
These messages were added:
Error Message DOT1X-4-MEM_UNAVAIL: Memory was not available to perform the 802.1X action. AuditSessionID [chars]Explanation The system memory is not sufficient to perform the IEEE 802.1x authentication. [chars] is the session ID.
Recommended Action Reduce other system activity to reduce memory demands.
Error Message DOT1X-5-FAIL: Authentication failed for client ([chars]) on Interface [chars] AuditSessionID [chars]Explanation The authentication was unsuccessful. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID.
Recommended Action No action is required.
Error Message %DOT1X-5-RESULT_OVERRIDE: Authentication result overridden for client ([chars]) on Interface [chars] AuditSessionID [chars]Recommended Action The authentication result was overridden. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID.
Explanation No action is required.
Error Message DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on Interface [chars] AuditSessionID [chars]Explanation Authentication was successful. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID.
Recommended Action No action is required.
Error Message DOT1X_SWITCH-5-ERR_ADDING_ADDRESS: Unable to add address [enet] on [chars] AuditSessionID [chars]Explanation The client MAC address could not be added to the MAC address table because the hardware memory is full or the address is a secure address on another port. This message might appear if IEEE 802.1x is enabled. [enet] is the client MAC address, the first [chars] is the interface, and the second [chars] is the session ID.
Recommended Action If the hardware memory is full, remove some of the dynamic MAC addresses. If the client address is on another port, remove it from that port.
Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a primary VLAN to an IEEE 802.1x port, which is not allowed. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Use a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid secondary VLAN [dec] to PVLAN host 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host IEEE 802.1x port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the mode of the port so that it is no longer a PVLAN host port or use a valid secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_PRIMARY_VLAN_NOT_FOUND: Attempt to assign VLAN [dec], whose primary VLAN does not exist or is shutdown, to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a private VLAN whose primary VLAN does not exist or is shut down. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Make sure the primary VLAN exists and is not shut down. Verify that the private VLAN is associated with a primary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SEC_VLAN_INVALID: Attempt to assign secondary VLAN [dec] to non-PVLAN host 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a secondary VLAN to a port that is not a private VLAN host port, which is not allowed. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the mode of the port so that it is configured as a private VLAN host port, or use a different VLAN that is not configured as a secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SPAN_DST_PORT: Attempt to assign VLAN [dec] to 802.1x port [chars], which is configured as a SPAN destination AuditSessionID [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port that is configured as a Switched Port Analyzer (SPAN) destination port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the SPAN configuration so that the port is no longer a SPAN destination port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_MDA_INACTIVE: Multi-Domain Authentication cannot activate because Data and Voice VLANs are the same on port AuditSessionID [chars]Explanation Multi-Domain Authentication (MDA) host mode cannot start if the configured data VLAN on a port is the same as the voice VLAN. [chars] is the port session ID.
Recommended Action Change either the voice VLAN or the access VLAN on the interface so that they are not the same. MDA then starts.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_VVLAN: Data VLAN [dec] on port [chars] cannot be equivalent to the Voice VLAN AuditSessionID [chars]Explanation An attempt was made to assign a data VLAN to an IEEE 802.1x port that is the same as the voice VLAN. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change either the voice VLAN or the IEEE 802.1x-assigned VLAN on the interface so that they are not the same.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INTERNAL: Attempt to assign internal VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is used internally and cannot be assigned to this port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Explanation Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INVALID: Attempt to assign invalid VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is out of range. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Update the configuration to use a valid VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND: Attempt to assign non-existent or shutdown VLAN [chars] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port, but the VLAN was not found in the VLAN Trunking Protocol (VTP) database. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Make sure the VLAN exists and is not shutdown or use another VLAN.
These messages have been deleted:
Error Message DOT1X-4-MEM_UNAVAIL: Memory was not available to perform the 802.1X action.Explanation The system memory is not sufficient to perform the IEEE 802.1x authentication.
Recommended Action Reduce other system activity to reduce memory demands.
Error Message DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on Interface [chars]Explanation Authentication was successful. [chars] is the interface.
Recommended Action No action is required.
Error Message DOT1X_SWITCH-5-ERR_ADDING_ADDRESS: Unable to add address [enet] on [chars]Explanation The client MAC address could not be added to the MAC address table because the hardware memory is full or the address is a secure address on another port. This message might appear if IEEE 802.1x is enabled. [enet] is the client MAC address, and [chars] is the interface.
Recommended Action If the hardware memory is full, remove some of the dynamic MAC addresses. If the client address is on another port, remove it from that port.
Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign a primary VLAN to an IEEE 802.1x port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Use a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid secondary VLAN [dec] to PVLAN host 802.1x port [chars]Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host IEEE 802.1x port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the mode of the port so that it is no longer a private VLAN host port, or use a valid secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_PRIMARY_VLAN_NOT_FOUND: Attempt to assign VLAN [dec], whose primary VLAN does not exist or is shutdown, to 802.1x port [chars]Explanation An attempt was made to assign a private VLAN whose primary VLAN does not exist or is shut down. [dec] is the VLAN, and [chars] is the port.
Recommended Action Make sure the primary VLAN exists and is not shut down. Verify that the private VLAN is associated with a primary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SEC_VLAN_INVALID: Attempt to assign secondary VLAN [dec] to non-PVLAN host 802.1x port [chars]Explanation An attempt was made to assign a secondary VLAN to a port that is not a private VLAN host port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the mode of the port so that it is configured as a private VLAN host port, or use a different VLAN that is not configured as a secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SPAN_DST_PORT: Attempt to assign VLAN [dec] to 802.1x port [chars], which is configured as a SPAN destinationExplanation An attempt was made to assign a VLAN to an IEEE 802.1x port that is configured as a Switched Port Analyzer (SPAN) destination port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the SPAN configuration so that the port is no longer a SPAN destination port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_MDA_INACTIVE: Multi-Domain Authentication cannot activate because Data and Voice VLANs are the same on port [chars]Recommended Action Multi-Domain Authentication (MDA) host mode cannot start if the configured data VLAN on a port is the same as the voice VLAN. [chars] is the port.
Recommended Action Change either the voice VLAN or the access VLAN on the interface so that they are not the same. MDA then starts.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_VVLAN: Data VLAN [dec] on port [chars] cannot be equivalent to the Voice VLAN.Explanation An attempt was made to assign a data VLAN to an IEEE 802.1x port that is the same as the voice VLAN. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change either the voice VLAN or the IEEE 802.1x-assigned VLAN on the interface so that they are not the same.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INTERNAL: Attempt to assign internal VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is used internally and cannot be assigned to this port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INVALID: Attempt to assign invalid VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is out of range. [dec] is the VLAN, and [chars] is the port.
Recommended Action Update the configuration to use a valid VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND: Attempt to assign non-existent or shutdown VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port, but the VLAN was not found in the VLAN Trunking Protocol (VTP) database. [dec] is the VLAN, and [chars] is the port.
Recommended Action Make sure that the VLAN exists and is not shut down, or use another VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_ON_ROUTED_PORT: Dot1x cannot assign a VLAN [dec] to a routed port [chars]Explanation An attempt was made to assign a VLAN to a supplicant on a routed port, which is not allowed. [dec] is the VLAN ID and [chars] is the port.
Recommended Action Either disable the VLAN assignment, or change the port type to a nonrouted port.
Error Message DOT1X_SWITCH-5-ERR_VLAN_PROMISC_PORT: Attempt to assign VLAN [dec] to promiscuous 802.1x port [chars]Explanation An attempt was made to assign a VLAN to a promiscuous IEEE 802.1x port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the port mode so that it is no longer a promiscuous port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_RESERVED: Attempt to assign reserved VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is a reserved VLAN and cannot be assigned to this port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_RSPAN: Attempt to assign RSPAN VLAN [dec] to 802.1x port [chars]. 802.1x is incompatible with RSPANExplanation This message means that remote SPAN should not be enabled on a VLAN with IEEE 802.1x-enabled. [dec] is the VLAN, and [chars] is the port.
Recommended Action Either disable remote SPAN configuration on the VLAN, or disable IEEE 802.1x on all the ports in this VLAN.
Error Message SW_VLAN-4-VTP_USER_NOTIFICATION: VTP protocol user notification: [chars].Explanation This message means that the VTP code encountered an unusual diagnostic situation. [chars] is a description of the situation.
Recommended Action Find out more about the error by using the show tech-support privileged EXEC command. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case with the TAC, or contact your Cisco technical support representative, and provide the representative with the gathered information.
Related Documentation
These documents provide complete information about the Cisco Catalyst Blade Switch 3130 and 3032 for Dell and are available on Cisco.com:
You can order printed copies of documents with a DOC-xxxxxx= number. For more information, see the "Obtaining Documentation and Submitting a Service Request" section.
These documents provide complete information about the switch module and are available from this Cisco.com site:
http://www.cisco.com/en/US/products/ps6748/tsd_products_support_series_home.html
•Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Getting Started Guide
•Regulatory Compliance and Safety Information for the Cisco Catalyst Blade Switch 3000 Series for Dell
•Release Notes for the Cisco Catalyst Blade Switch 3130 and 3032 for Dell
Note Before you install, configure, or upgrade the switch module, see the release notes on Cisco.com for the latest information.
•Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
•Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference Cisco Catalyst Blade Switch 3130 and 3032 for Dell System Message Guide (not orderable but available on Cisco.com)
•Cisco Software Activation Document for Dell
•These compatibility matrix documents are available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
–Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix
–Cisco Small Form-Factor Pluggable Modules Compatibility Matrix
–Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable Modules
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
CCDE, CCENT, CCSI, Cisco Eos, Cisco Explorer, Cisco HealthPresence, Cisco IronPort, the Cisco logo, Cisco Nurse Connect, Cisco Pulse, Cisco SensorBase, Cisco StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco TrustSec, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels, Flip for Good, Flip Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (Design), Instant Broadband, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn, Cisco Capital, Cisco Capital (Design), Cisco:Financed (Stylized), Cisco Store, Flip Gift Card, and One Million Acts of Green are service marks; and Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Lumin, Cisco Nexus, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center, Explorer, Follow Me Browsing, GainMaker, iLYNX, IOS, iPhone, IronPort, the IronPort logo, Laser Link, LightStream, Linksys, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, PCNow, PIX, PowerKEY, PowerPanels, PowerTV, PowerTV (Design), PowerVu, Prisma, ProConnect, ROSA, SenderBase, SMARTnet, Spectrum Expert, StackWise, WebEx, and the WebEx logo are registered trademarks of Cisco and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1002R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
© 2009-2010 Cisco Systems, Inc. All rights reserved.