Guest

Cisco ICS 7700 Series Integrated Communication Systems

Cisco ICS 7750 FRU Installation and Replacement, 2.5.0

  • Viewing Options

  • PDF (958.9 KB)
  • Feedback
Cisco ICS 7750 FRU Installation and Replacement

Table Of Contents

Cisco ICS 7750 FRU Installation and Replacement

Contents

Document Conventions

Required Tools and Equipment

PC Requirements

Safety Precautions and Maintenance Guidelines

General Safety Precautions

ESD Safety Precautions

Safety with Electricity

Ground Conductor Warning

Use Copper Conductors Only

Electrical Storm Warning

Telephone Jacks in Wet Locations Warning

Uninsulated Wires and Terminals Warning

Line Installation or Modification Warning

Telephone Use During an Electrical Storm Warning

Telephone Use by Gas Leaks Warning

Installation Hazard

Grounding Requirement Warning

More Than One Power Supply Warning

Telephone Wiring Guidelines

Lifting and Reaching Safety Precautions

System Component Identification

Removing and Replacing Cisco ICS 7750 Components

Best Practices for Hot Swapping

Best Practices for Card Replacement

Best Practices for Resetting or Removing Cards

Best Practices for Inspecting the Chassis Backplane and Card Connectors Before Installing Cards

Best Practices for Installing Cards

Removing and Replacing SPE310s

Accessing the SPE310

Accessing the SPE310 Windows Interface Through Terminal Services Client

Accessing the SPE310 Windows Interface Through Directly Connected Peripherals

Installing Microsoft Terminal Services Client

Determining the Function of an SPE

Removing an SPE

Installing an SPE

Verifying SPE Installation

Configuring a New or Replacement SPE

SPE Installation and Replacement Scenarios

Installing a New SPE for Applications

Replacing an Existing SPE for Applications

Replacing the SPE Running System Manager

Converting the ICS Core Software to ICS System Manager Software

Configuring Your PC IP Address

Configuring Your Web Browser for System Manager

Using ICSConfig to Configure and Verify the SPE Running System Manager

Accessing ICS System Manager and Restoring Cisco ICS 7750 Functionality

Installing Applications and Restoring Saved Application Software Data

Downgrading ICS System Software

Removing and Replacing ASIs, MRPs, the SSP, or the SAP

Backing Up and Restoring Flash-Based MRPs, ASIs, and the SSP

Removing an ASI, MRP, SSP, or SAP

Installing or Replacing an ASI or MRP

Replacing an MRP200 or ASI Card with a Flash-Based MRP Card

Removing and Replacing Interface Cards in ASI81s, MRP3-8FXSs, or MRPs

Electrical Storm Warning

Telephone Jacks in Wet Locations Warning

Uninsulated Wires and Terminals Warning

Line Installation or Modification Warning

Telephone Use During an Electrical Storm Warning

Telephone Use by Gas Leaks Warning

Installation Hazard

Before You Begin

Installing or Replacing an Interface Card in an ASI81, MRP, or MRP3-8FXS

Configuring VLAN Support on the Flash-Based MRP

Replacing the SSP and the SAP

Backing up and Restoring the VLAN Configuration on the SSP

Replacing the SSP

Configuring VLAN Support on the SSP

Replacing the SAP

Removing and Replacing Power Supply Modules

Removing Power Supply Modules

Installing Power Supply Modules

Removing and Replacing the Fan Tray

Removing the Fan Tray

Installing a Fan Tray

Verifying Card Installation

RMA Return Instructions

Checking the Status of Returned RMA Parts

Obtaining Documentation

World Wide Web

Documentation CD-ROM

Ordering Documentation

Documentation Feedback

Obtaining Technical Assistance

Cisco.com

Technical Assistance Center

Cisco TAC Web Site

Cisco TAC Escalation Center


Cisco ICS 7750 FRU Installation and Replacement


October 2, 2002

This document explains how to install and remove field-replaceable units (FRUs) in the Cisco Integrated Communications System (ICS) 7750 (referred to as the Cisco ICS 7750).

The following Cisco ICS 7750 components are FRUs:

Analog station interface (ASI) cards.

Fan tray.

Multiservice route processor (MRP) 200 and 300 cards.

MRP3-8FXS and MRP3-16FXS cards.

Power supply modules.

System alarm processor (SAP) card.

System processing engine (SPE) 310 cards.

System switch processor (SSP) card.

Voice interface cards (VICs), voice WAN interface cards (VWICs), and WAN interface cards (WICs). VICs, VWICs, and WICs are subcomponents of ASIs and MRPs.


Note This document is not intended for use with SPE200s. If you need assistance with an SPE200, contact the Cisco Technical Assistance Center (see the "Technical Assistance Center" section).



Note The MRP200 and MRP300 cards are both voice-and-data-capable routers that support digital and analog voice trunks and WAN routing interfaces to link remote Ethernet LANs to the Public Switched Telephone Network (PSTN), to existing private branch exchanges (PBXs), and to most common analog devices, such as fax machines and teleconferencing stations. The MRP300 has additional functionality provided by 16 MB of onboard Flash memory, with 64 MB of add-on Flash memory available as an option. Configuration files for the MRP200 are loaded and saved to the SPE running System Manager, whereas configuration files for the MRP300 are loaded and saved on the MRP300 in nonvolatile RAM (NVRAM).



Note The ASI81 and MRP3-8FXS cards are both voice-and-data-capable routers that can carry voice traffic over an IP network to link remote Ethernet LANs to central offices over WAN links (depending on the type of card installed in its WIC/VIC/VWIC slot). Each card can support eight connections to analog telephones, fax machines, and teleconferencing stations. The MRP3-8FXS has additional functionality provided by 16 MB of onboard Flash memory, with 64 MB of add-on Flash memory available as an option. Configuration files for the MRP3-8FXS are loaded and saved on the MRP3-8FXS in NVRAM. The MRP3-16FXS card has the same Flash memory capability, with support for 16 connections. (The ASI160 card also supports 16 connections, but does not have the capability for Flash memory.)



Caution Beginning with release 2.5.0, ICS System Software has been enhanced to include support for virtual local area networks (VLANs) and quality of service (QoS) on the Cisco ICS 7750. With this support, you can enable VLAN usage by configuring all system cards on the management VLAN (VLAN 1); you can also configure multiple data and voice VLANs outside of the Cisco ICS 7750 chassis. The implementation of VLANs and QoS includes the ability for the Flash-based MRP cards (MRP300, MRP3-8FXS, and MRP3-16FXS) to be configured as VLAN routers to route between multiple VLANs configured on the LAN. As VLAN routers, the Flash-based MRP cards can reside on other VLANs besides VLAN 1. Additional functionality provided by a DHCP server on the Flash-based MRP cards can be configured to provision IP addresses for external devices, such as PCs and phones, on VLANs other than VLAN 1.

To enable VLAN functionality on the Cisco ICS 7750, you need to manually configure both the VLAN-capable, Flash-based MRP card and the SSP through the IOS command-line interface (CLI). For detailed information about VLAN functionality on the Cisco ICS 7750, refer to the Cisco ICS 7750 Installation and Configuration Guide. For information about configuring VLANs, refer to the "Configuring VLANs" section in the Catalyst 2900 XL and Catalyst 3500 XL Software Configuration Guide, Releases 12.0(5)WC4 and 12.0(5)WC5. For information about configuring a DHCP server on the Flash-based MRP card, refer to the "Configuring DHCP" section in the Cisco IOS IP Configuration Guide, Release 12.2.


Note For a description of the features, modifications, and caveats for the Cisco Integrated Communications System 7750 (Cisco ICS 7750) release 2.5.0, refer to the
Release Notes for System Software Release 2.5.0 on the Cisco ICS 7750.



Note For information about removing and replacing dual in-line memory modules (DIMMs), packet voice data modules (PVDMs), and Virtual Private Networking (VPN) modules, refer to Installing Memory, PVDM, and VPN Modules in ASI Cards, MRP Cards, and SPE Cards in the Cisco ICS 7750. For additional information about system hardware, refer to the
Cisco ICS 7750 System Description and the Cisco ICS 7750 Installation and Configuration Guide.


Contents

This document contains the following sections:

Document Conventions

Required Tools and Equipment

Safety Precautions and Maintenance Guidelines

System Component Identification

Removing and Replacing Cisco ICS 7750 Components

Removing and Replacing SPE310s

Removing and Replacing ASIs, MRPs, the SSP, or the SAP

Removing and Replacing Interface Cards in ASI81s, MRP3-8FXSs, or MRPs

Removing and Replacing Power Supply Modules

Removing and Replacing the Fan Tray

Verifying Card Installation

RMA Return Instructions

Obtaining Documentation

Obtaining Technical Assistance

Document Conventions

This publication uses the following conventions:


Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual.



Caution Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.

Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Waarschuwing

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

Varoitus

Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Warnung

Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

Avvertenza

Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

Advarsel

Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

Aviso

Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.

¡Advertencia!

Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Varning!

Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.


Required Tools and Equipment


Warning Only personnel who are trained and qualified (IP Telephony certified for the Cisco ICS 7750) should be allowed to install or replace this equipment.


You need the following tools and parts to install and maintain the system. If you need additional equipment, contact a customer service representative for ordering information.

A number-1 Phillips screwdriver for installing the cable management bracket (recommended) and mounting the system.

A 6-mm open-end wrench for adjusting the grounding lug.

ESD-prevention equipment or the disposable ESD-preventive wrist strap included in the hardware accessory kit.

Antistatic mat, foam pad, or bag for removed cards or modules. (Put removed components inside an antistatic bag if you plan to return them to the factory; if you are replacing components, place them on an antistatic mat or foam pad.)

Cables and adapters:

1 straight-through Category 5 Ethernet cable.

1 RJ-45-to-DB-9 adapter.

1 console (rolled EIA/TIA-232) cable.

To remove, install, and replace SPEs, you need the following additional tools and parts:

Cisco ICS 7750 chassis equipped with one or more SPE310s.

One or more spare SPE310s.

(Optional) Application CDs for applications to be installed on the SPE(s) (for example, Cisco CallManager software for the Cisco ICS 7750).

Windows-based PC or laptop, which may be connected both to the SSP Ethernet port and the SAP console port. (Specific requirements for this PC are described in the "PC Requirements" section.)

Cisco ICS 7750 System Software, which can be installed from the following sources, with the following options:

CD-ROM—The system software release 2.x.x CD-ROM contains a complete set of the system software, including Microsoft SQL Server software and Microsoft hotfixes. The CD-ROM can be used to install release 2.x.x on an SPE310 that does not currently have system software installed, or it can be used to upgrade an SPE310 that currently has system software release 2.1.0 or higher installed.

For instructions on installing the software from the CD-ROM, refer to the "Upgrading System Software on SPE310s from the CD-ROM" section in Chapter 8, "Maintaining the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide. For download and installation instructions from CCO, refer to the "Downloading and Installing System Software" section in Chapter 8, "Maintaining the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide.

CCO—Two sets of system software release 2.x.x are available for downloading from CCO:

S77a-2.x.x.exe—This package contains the complete set of system software version 2.x.x, including Microsoft SQL Server software. You can use this package for new installations or upgrades of existing system software.

S77a-Upgrade-2.x.x.exe—This package contains only the software components changed since release 2.1.0 and necessary to upgrade the ICS System Software from release 2.1.0 or later. Because it does not contain Microsoft SQL Server software, the package is smaller and requires less download time. You cannot use this upgrade package for SPE310 reimaging or reinstallation of ICS System Software.

You can install ICS System Manager Software on only one SPE310 in the chassis. On any additional SPE310s in the chassis, install ICS Core Software. Refer to the Cisco ICS 7750 Installation and Configuration Guide for information about the applicable system software installation options.

The Cisco ICS 7750 system software packages use the naming conventions shown in Table 1.

Table 1 Cisco ICS 7750 System Software Packages 

System Software Package Name 1
Feature Set
IOS Software Image (for MRPs and ASIs)

S77a-x.x.x.exe

SNMP2 , IP, Bridging, SRB3 , Voice, Reduced IP (SNMP, IP RIP4 /IGRP5 /EIGRP6 , Bridging, ISDN, PPP)

ics7700-sv3y-mz

S77a-Upgrade-x.x.x.exe

SNMP, IP, Bridging, SRB, Voice, Reduced IP (SNMP, IP RIP/IGRP/EIGRP, Bridging, ISDN, PPP)

ics7700-sv3y-mz

1 Each system software package contains an IOS software image for the MRPs and ASIs, an IOS software image for the SSP, ICS System Manager, and ICS Core Software. The first system software package listed is the full Cisco ICS 7750 System Software package, which can be used for a full installation or an upgrade of existing system software. The second system software package listed is for software upgrades of existing Cisco ICS 7750 system software only. This package will be available only on CCO. See the "Required Tools and Equipment" section for the URL of the CCO software.

2 SNMP = Simple Network Management Protocol.

3 SRB = source-route bridging.

4 RIP = Routing Information Protocol.

5 IGRP = Interior Gateway Routing Protocol.

6 EIGRP = Enhanced Interior Gateway Routing Protocol.



Note Beginning with ICS System Software release 2.4.0, the Cisco ICS 7750 System Software installation CD contents and upgrade-only packages have been available on CCO in a compressed format. The files distributed on CCO are packaged as a single self-extracting EXE. Refer to the Cisco Voice Software download page at http://www.cisco.com/kobayashi/sw-center/sw-voice.shtml for the CCO version. You will have to download the EXE file to your SPE310 and then invoke the executable by double-clicking the file. This expands the package files and automatically creates the directory structure required for installation. For installation instructions, refer to the "Upgrading System Software" section in Chapter 8, "Maintaining the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide.



Note The full ICS System Software package (CD or CCO version) is needed if you are replacing the SPE running System Manager.


PC Requirements

You may choose to use a PC (or laptop computer) to download and install software and to perform system management tasks, such as remote configuration or troubleshooting. The PC does not need to be physically near the ICS 7750 chassis because tasks can be executed locally on the SPE310 with an attached keyboard, mouse, and monitor.

Ensure that the PC meets the following requirements:

CPU: Pentium-class 233 MHz or faster

Memory: At least 64 MB of RAM

Hardware:

CD-ROM drive

Network interface card (NIC)

Available COM port

PC keyboard with PS/2-style or USB (Universal Serial Bus) connector

Windows-compatible mouse with PS/2-style or USB or connector

Monitor: SVGA monitor or LCD display with at least 800 x 600 resolution and at least 256 colors (1024 x 768 resolution is recommended)

Operating system: Microsoft Windows 98, Windows Me, Windows XP, Windows NT, or Windows 2000

Web browser: Netscape Communicator 4.7 or later, or Internet Explorer 5.5 or later, with Java plug-in version 1.3.1 or later (refer to the Cisco Software Download web site at http://www.cisco.com/pcgi-bin/tablebuild.pl/java).

Communication software: Microsoft Terminal Services Client


Note Refer to the Cisco ICS 7750 Installation and Configuration Guide for information about initial hardware installation and software configuration steps.


Safety Precautions and Maintenance Guidelines


Note The following guidelines are IMPORTANT SAFETY INSTRUCTIONS.


This section describes guidelines that you should follow when working on the Cisco ICS 7750.

General Safety Precautions

Read the warnings in this section before working on the system.


Warning Read the installation instructions before you connect the system to its power source.



Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.



Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 16A international) is used on the phase conductors (all current-carrying conductors).



Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.



Warning Only personnel who are trained and qualified (IP Telephony certified for the Cisco ICS 7750) should be allowed to install or replace this equipment.



Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.



Warning The device is designed to work with TN power systems.



Warning The SPE contains a lithium battery. There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.


ESD Safety Precautions

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD occurs when electronic printed circuit cards are improperly handled. ESD can result in complete or intermittent failures. Always follow these ESD-prevention procedures when removing and replacing cards and other system components:

Ensure that the chassis is electrically connected to earth ground.

Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact.

Connect the clip to an unpainted surface of the chassis frame to safely channel ESD voltages to ground.

To properly guard against ESD damage and shocks, the wrist strap must be used correctly. If no wrist strap is available, ground yourself by touching the metal part of the chassis.


Caution For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms (Mohms).


Caution Static voltages as low as 30 volts can cause latent damage to circuitry. Be sure to observe all standard antistatic procedures (for example, wear a grounding strap) when handling electronic equipment and components.


Warning Blank faceplates (filler panels) serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards and faceplates are in place.


Safety with Electricity

Follow these guidelines when working on equipment powered by electricity:

Locate the emergency power-off switch in the room in which you are working. Then, if an electrical accident occurs, you can quickly shut the power off.

Disconnect all power before installing or removing a Cisco ICS 7750 chassis.

Do not work alone if potentially hazardous conditions exist.

Never assume that power is disconnected from a circuit. Always check.

Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, and missing safety grounds.

If an electrical accident occurs, proceed as follows:

Use caution; do not become a victim yourself.

Turn off power to the chassis.

If possible, send another person to get medical aid. Otherwise, determine the condition of the victim, and then call for help.

Determine whether the victim needs rescue breathing or external cardiac compressions; then take appropriate action.

Ground Conductor Warning

Warning Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.

Waarschuwing

De aardingsleiding mag nooit buiten werking gesteld worden en de apparatuur mag nooit bediend worden zonder dat er een op de juiste wijze geïnstalleerde aardingsleiding aanwezig is. Neem contact op met de bevoegde instantie voor elektrische inspecties of met een elektricien als u niet zeker weet of voor passende aarding gezorgd is.

Varoitus

Älä koskaan ohita maajohdinta tai käytä laitteita ilman oikein asennettua maajohdinta. Ota yhteyttä asianmukaiseen sähkötarkastusviranomaiseen tai sähköasentajaan, jos olet epävarma maadoituksen sopivuudesta.

Attention

Ne jamais rendre inopérant le conducteur de masse ni utiliser l'équipement sans un conducteur de masse adéquatement installé. En cas de doute sur la mise à la masse appropriée disponible, s'adresser à l'organisme responsable de la sécurité électrique ou à un électricien.

Warnung

Umgehen Sie auf keinen Fall den Erdungsleiter und nehmen Sie die Geräte nicht in Betrieb, wenn der Erdungsleiter nicht sachgemäß installiert ist. Wenden Sie sich an die entsprechende Behörde, die für die Inspektion elektrischer Anlagen zuständig ist, oder an einen Elektriker, wenn Sie nicht sicher sind, ob der Anschluß ordnungsgemäß geerdet ist.

Avvertenza

Non escludere mai il conduttore di protezione né usare l'apparecchiatura in assenza di un conduttore di protezione installato in modo corretto. Se non si sa con certezza che è disponibile un collegamento di messa a terra adeguato, esaminare le Norme CEI pertinenti o rivolgersi a un elettricista qualificato.

Advarsel

Jordingslederen må aldri hindres, og utstyret må aldri brukes uten at en forsvarlig jordingsleder er installert. Kontakt elektrisitetstilsynet eller en elektriker dersom du er usikker på om riktig jording er tilgjengelig.

Aviso

Nunca anule o condutor à terra nem opere o equipamento sem ter um condutor à terra adequadamente instalado. Em caso de dúvida em relação ao sistema de ligação à terra, contacte os serviços locais de inspecção eléctrica ou um electricista qualificado.

¡Advertencia!

No desactive nunca el conductor de tierra ni opere el equipo sin un conductor de tierra instalado correctamente. Póngase en contacto con las autoridades de inspección eléctrica pertinentes o con un electricista, si no está seguro de contar con una toma de tierra adecuada.

Varning!

Koppla aldrig från jordledningen och använd aldrig utrustningen utan en på lämpligt sätt installerad jordledning. Om det föreligger osäkerhet huruvida lämplig jordning finns skall elektrisk besiktningsauktoritet eller elektriker kontaktas.


Use Copper Conductors Only

Warning Use copper conductors only.

Waarschuwing

Gebruik alleen koperen geleiders.

Varoitus

Käytä vain kuparijohtimia.

Attention

Utilisez uniquement des conducteurs en cuivre.

Warnung

Verwenden Sie ausschließlich Kupferleiter.

Avvertenza

Usate unicamente dei conduttori di rame.

Advarsel

Bruk bare kobberledninger.

Aviso

Utilize apenas fios condutores de cobre.

¡Advertencia!

Emplee sólo conductores de cobre.

Varning!

Använd endast ledare av koppar.


Electrical Storm Warning

Warning Never install telephone wiring during an electrical storm.

Waarschuwing

Installeer telefoondraden nooit tijdens een onweersbui.

Varoitus

Älä asenna puhelinjohtoja ukkosmyrskyn aikana.

Attention

Ne jamais installer des câbles téléphoniques pendant un orage.

Warnung

Installieren Sie eine Telefonverkablung niemals während eines Gewitters!

Avvertenza

Mai installare cavi telefonici durante un temporale elettrico.

Advarsel

Telefonledninger skal aldri monteres i tordenvær.

Aviso

Nunca instalar fios telefónicos durante uma tempestade eléctrica.

¡Advertencia!

Nunca instale el cableado del teléfono durante una tormenta.

Varning!

Telefonledningar får aldrig anslutas under åskväder.


Telephone Jacks in Wet Locations Warning

Warning Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Waarschuwing

Installeer telefoonaansluitingen nooit op vochtige locaties tenzij de aansluiting speciaal bestemd is voor vochtige locaties.

Varoitus

Älä asenna puhelimen pistokkeita kosteisiin tiloihin, ellei pistokkeita ole nimenomaisesti suunniteltu tällaisiin tiloihin.

Attention

Ne jamais installer de prises téléphoniques dans un local humide, sauf si celles-ci sont spécifiquement conçues pour cet usage.

Warnung

Telefonanschlüsse niemals in feuchten Umgebungen installieren, es sei denn der Anschluß ist speziell für Feuchtumgebungen entwickelt!

Avvertenza

Mai installare un jack telefonico in una zona bagnata almeno che il jack sia appositamente per zone bagnate.

Advarsel

Telefonkontakter skal aldri monteres i fuktige omgivelser, med mindre kontakten er spesielt laget for våtrom.

Aviso

Nunca instalar tomadas telefónicas em locais húmidos, a menos que a tomada tenha sido especialmente concebida para esse efeito.

¡Advertencia!

Nunca instale las rosetas del teléfono en zonas mojadas a menos que la roseta se diseñe específicamente para estas.

Varning!

Endast specialkonstruerat telefonjack får installeras i våtutrymme.


Uninsulated Wires and Terminals Warning

Warning Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Waarschuwing

Raak ongeïsoleerde telefoondraden of contacten nooit aan tenzij de telefoonlijn van de netwerkinterface werd ontkoppeld.

Varoitus

Älä kosketa eristämättömiä puhelinjohtoja tai liittimiä, ellei puhelinta ole irrotettu verkkoliittymästä.

Attention

Ne jamais toucher un câble téléphonique non isolé lorsque celui-ci est connecté au port réseau.

Warnung

Niemals nicht-isolierte Telefonkabel berühren, außer wenn die Telefonleitung an der Netzwerkschnittstelle abgetrennt wurde!

Avvertenza

Mai toccare cavi telefonici o terminali non isolati almeno che le linee telefoniche non siano state disconnesse dall'interfaccia rete.

Advarsel

Telefonledninger eller -uttak som ikke er isolert, må aldri berøres, med mindre telefonlinjen er frakoplet telenettet.

Aviso

Nunca tocar em fios ou terminais telefónicos não isolados, a menos que a linha telefónica tenha sido desligada ao nível da interface da rede.

¡Advertencia!

Nunca toque los alambres o los terminales del teléfono a menos que la línea telefónica se haya desconectado en el interfaz de la red.

Varning!

Telefonlinjer måste frånkopplas vid nätverksgränssnittet innan oisolerad telefonledning eller -uttag vidrörs.


Line Installation or Modification Warning

Warning Use caution when installing or modifying telephone lines.

Waarschuwing

Wees voorzichtig bij het installeren of modificeren van telefoonlijnen.

Varoitus

Ole varovainen, kun asennat puhelinlinjoja tai teet niihin muutoksia.

Attention

Une extrême prudence est recommandée lors de l'installation ou de la modification de lignes téléphoniques.

Warnung

Achtung bei der Installation und Modifikation von Telefonleitungen!

Avvertenza

Installate o modificate le linee telefoniche con molta cautela.

Advarsel

Det må utvises forsiktighet ved montering eller justering av telefonlinjer.

Aviso

Tomar as devidas precauções ao instalar ou alterar linhas telefónicas.

¡Advertencia!

Precaución al instalar o modificar las líneas telefónicas.

Varning!

Iakttag försiktighet vid installation eller modifiering av telefonlinjer.


Telephone Use During an Electrical Storm Warning

Warning Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

Waarschuwing

Gebruik nooit een telefoon (tenzij het een draadloze telefoon is) tijdens onweer. Er bestaat een kleine kans op een elektrische schok door bliksem.

Varoitus

Vältä puhelimen (muun kuin langattoman puhelimen) käyttöä ukkosmyrskyn aikana. Salamoinnista voi aiheutua sähköiskuvaara.

Attention

Pour éviter tout risque de choc électrique lors d'un orage, il est recommandé de ne pas utiliser un téléphone autre qu'un appareil sans fil.

Warnung

Vermeiden Sie die Benutzung eines Telefons während eines Gewitters (außer eines schnurlosen Geräts). Es besteht ein geringes Risiko eines elektrischem Schlags durch Blitze.

Avvertenza

Non utilizzate il telefono (almeno che sia cellulare) durante un temporale elettrico. Ci sono rischi, anche se poco probabili, di scariche elettriche dovute a fulmini.

Advarsel

Unngå å bruke telefonen (med mindre den er trådløs) i tordenvær. Det eksisterer en minimal risiko for elektrisk støt grunnet lynnedslag.

Aviso

Evitar a utilização do telefone (que não seja do tipo sem fios) durante uma tempestade eléctrica. Pode haver o risco remoto de choque eléctrico provocado pelo relâmpago.

¡Advertencia!

Evite usar el teléfono (a excepción de un teléfono inalámbrico) durante una tormenta. Puede correr peligro por la descarga eléctrica que emite el relámpago.

Varning!

Undvik att telefonera (gäller ej trådlös telefon) under åskväder. Viss risk finns för elstöt vid blixtnedslag.


Telephone Use by Gas Leaks Warning

Warning Do not use a telephone to report a gas leak in the vicinity of the leak.

Waarschuwing

Gebruik nooit een telefoon om een gaslek te melden als de telefoon zich in de buurt van het gaslek bevindt.

Varoitus

Älä ilmoita kaasuvuodosta puhelimitse, jos olet vuodon lähettyvillä.

Attention

Ne jamais utiliser un téléphone près d'une fuite de gaz pour signaler cette fuite à votre société de distribution.

Warnung

Um ein Leck in einer Gasleitung zu melden, benutzen Sie nicht ein Telefongerät in der Nähe des Lecks.

Avvertenza

Non utilizzate un telefono per avvertire di una perdita di gas nelle vicinanze della perdita.

Advarsel

Du skal ikke bruke telefon til å melde fra om en gasslekkasje i nærheten av denne lekkasjen.

Aviso

Não utilizar o telefone para comunicar uma fuga de gás nas proximidades dessa fuga.

¡Advertencia!

No utilice un teléfono para informar de un escape de gas en la zona.

Varning!

Telefonera ej i närheten vid rapportering om gasläcka.


Installation Hazard

Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector and/or 2) while the housing is open.

Waarschuwing

Deze uitrusting dient geïnstalleerd en onderhouden te worden door onderhoudspersoneel zoals gedefinieerd door AS/NZS 3260. Als deze uitrusting onjuist op een stopcontact voor algemeen gebruik wordt aangesloten kan dit gevaarlijk zijn. De telecommunicatielijnen dienen ontkoppeld te worden 1) voordat de stekker naar de hoofdstroomtoevoer eruit wordt genomen en/of 2) terwijl de behuizing open is.

Varoitus

Huoltohenkilöstön on asennettava ja huollettava tämä laite AS/NZS 3260:n määräysten mukaisesti. Laitteen virheellinen kytkeminen yleispistorasiaan voi aiheuttaa vaaratilanteita. Tietoliikennejohdot on irrotettava 1) ennen kuin päävirtaliitin irrotetaan pistorasiasta ja/tai 2) kun kotelo on auki.

Attention

Cet équipement ne doit être installé et entretenu que par du personnel d'entretien comme défini par la réglementation AS/NZS 3260. Un branchement incorrect de cet équipement à une prise de courant peut créer une situation dangereuse. Les lignes de télécommunications doivent être déconnectées 1) avant de débrancher le connecteur d'alimentation principal et/ou 2) lorsque le boîtier est ouvert.

Warnung

Dieses Gerät ist nur von ausgebildetem Personal zu installieren und zu warten (lt. Definition in AS/NZS 3260). Fälschliches Anschließen des Geräts an eine normale Steckdose könnte gefährlich sein. Die Telekommunikationsleitungen dürfen 1) beim Herausziehen des Netzsteckers und/oder 2) bei geöffnetem Gehäuse nicht angeschlossen sein.

Avvertenza

Questo apparecchio deve essere installato e mantenuto in efficienza esclusivamente da personale tecnico che soddisfi i requisiti specificati nelle norme AS/NZS 3260. Un collegamento errato di questo apparecchio ad una presa di uso generale può essere pericoloso. Le linee di telecomunicazione vanno scollegate sia prima di scollegare la spina dell'alimentazione di rete sia prima di aprire l'involucro (non ricollegarle finché non si chiude l'involucro).

Advarsel

Dette utstyret må monteres og vedlikeholdes av vedlikeholdspersonell i henhold til AS/NZS 3260. Feilaktig tilkopling av dette utstyret til et vanlig strømuttak kan medføre fare. Telekommunikasjonslinjene må være frakoplet 1) før strømledningen trekkes ut av kontakten og/eller 2) mens huset er åpent.

Aviso

A instalação e a manutenção deste equipamento devem ser realizadas por pessoal da assistência, conforme definido na norma AS/NZS 3260. A ligação incorrecta deste equipamento a uma tomada de utilização geral poderá ser perigosa. As linhas de telecomunicações têm de estar desligadas 1) antes de desligar a ligação à corrente principal e/ou 2) enquanto a caixa estiver aberta.

¡Advertencia!

Este equipo se debe instalar y mantener solamente por personal de servicio, según definido por AS/NZS 3260. La conexión incorrecta de este equipo a una toma o receptáculo de tipo general podría resultar peligrosa. Las líneas de telecomunicaciones deben desconectarse 1) antes de desenchufar el conector principal de energía y 2) mientras la caja esté abierta.

Varning!

Denna utrustning måste installeras och underhållas av servicepersonal enligt AS/NZS 3260. Felaktig anslutning av denna utrustning till ett vanligt vägguttag kan medföra fara. Teleledningarna måste kopplas ifrån innan väggkontakten dras ut och/eller innan höljet tas av.


Grounding Requirement Warning

Warning This equipment needs to be grounded. Use a green and yellow 14 AWG ground wire to connect the host to earth ground during normal use.

Waarschuwing

Deze apparatuur hoort geaard te woden. Gebruik een groen/gele 14 AWG aarddraad om de host tijdens normaal gebruik met de aarde te verbinden.

Varoitus

Tämä laitteisto täytyy maadoittaa. Yhdistä isäntälaite maahan normaalikäytön aikana käyttämällä vihreä-keltaista 14 AWG -maadoitusjohtoa.

Attention

Cet équipement doit être relié à la terre. Utilisez un fil vert et jaune de gabarit 14 (AWG) pour connecter l'hôte à la terre lors son utilisation normale.

Warnung

Dieses Gerät muß geerdet werden. Verwenden Sie ein grün/gelbes 14-AWG-Erdungskabel, um damit das Host-Gerät während des normalen Betriebs zu erden.

Avvertenza

Questa apparecchiatura deve essere collegata a massa. Durante l'uso normale, collegare l'host alla massa di terra usando un filo di massa verde e giallo di diametro pari a 14 AWG.

Advarsel

Dette utstyret må jordes. Bruk en grønn og gul 14 AWG jordledning til å kople vertsterminalen til jording i løpet av normalt bruk.

Aviso

É necessário que este equipamento esteja ligado à terra. Utilize um fio de ligação à terra de 14 AWG, verde e amarelo, para ligar o host à ligação à terra durante a sua utilização normal.

Advertencia

Este equipo debe conectarse a tierra. Utilizar un hilo de puesta a tierra 14 AWG verde y amarillo para conectar a tierra el equipo principal durante el uso normal.

Varning!

Denna utrustning är avsedd att jordas. Använd en gulgrön jordledning av storlek 14 AWG till att jorda värdenheten vid normal användning.


Figure 1 shows the grounding stud that is located on the back of the Cisco ICS 7750 chassis.

Figure 1 Grounding Stud on the Cisco ICS 7750 Chassis

More Than One Power Supply Warning

Warning This unit might have more than one power supply connection. All connections need to be removed to de-energize the unit.

Waarschuwing

Deze eenheid kan meer dan één stroomtoevoerverbinding bevatten. Alle verbindingen dienen ontkoppeld te worden om de eenheid te ontkrachten.

Varoitus

Tässä laitteessa voi olla useampia kuin yksi virtakytkentä. Kaikki liitännät on irrotettava, jotta jännite poistetaan laitteesta.

Attention

Pour supprimer toute tension et tout courant électrique de l'unité, TOUTES les connexions d'alimentation doivent être débranchées.

Warnung

Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, daß der Einheit kein Strom zugeführt wird, müssen alle Verbindungen entfernt werden.

Avvertenza

Questo prodotto può avere più di una connessione di alimentazione elettrica. Tutte le connessioni devono essere staccate per togliere la corrente dal prodotto.

Advarsel

Denne enheten kan ha mer enn én strømtilførselskobling. Alle koblinger må fjernes fra enheten for å utkoble all strøm.

Aviso

Esta unidade poderá ter mais do que uma conexão de fonte de energia. Todas as conexões necessitam de ser removidas para desactivar a unidade.

¡Advertencia!

Esta unidad puede contar con más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones.

Varning!

Denna enhet har eventuellt mer än en strömförsörjningsanslutning. Alla anslutningar måste tas bort för att göra enheten strömlös.


Telephone Wiring Guidelines

Follow these guidelines when working with any equipment that is connected to telephone wiring or to other network cabling:

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Lifting and Reaching Safety Precautions

Follow these guidelines when lifting or moving the chassis:


Warning To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Lift the unit only by using handles that are an integral part of the chassis, or by grasping the chassis underneath its lower edge.



Warning Two people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back.



Note SAVE THESE INSTRUCTIONS.


System Component Identification

Figure 2 shows the major components in a typical Cisco ICS 7750:

Slots 1 through 6 can contain a combination of SPEs, ASIs, and MRPs.

Slot 7 must contain only an SSP.

Slot 8 must contain only an SAP.

The Power Supply 1 and Power Supply 2 slots can each contain a power supply module (only one power supply module is required to operate the system).

The system contains one fan tray, at the bottom of the chassis.


Note By factory-installed default, the Cisco ICS 7750 chassis comes with the SPE running System Manager installed in slot 6, and with SPEs populated from right to left. Other system cards (such as MRPs and ASIs) are populated from left to right in the chassis.


Figure 2 Cisco ICS 7750

Removing and Replacing Cisco ICS 7750 Components

This section provides general information about removing and replacing the Cisco ICS 7750 components. This section contains the following subsections:

Best Practices for Hot Swapping

Best Practices for Card Replacement

For detailed instructions for removing and replacing system components, see the following sections:

Removing and Replacing SPE310s

Removing and Replacing ASIs, MRPs, the SSP, or the SAP

Removing and Replacing Power Supply Modules

Removing and Replacing the Fan Tray


Warning When performing the procedures in this section, wear grounding wrist straps to avoid ESD damage to the Cisco ICS 7750. Do not directly touch the backplane with your hand or any metal tool to prevent personal injury or equipment damage.



Warning Removing cards, fans, and power supply modules can expose you to high-energy (high-amperage) circuits and possible ejection of molten metal or to the shock hazard of telephony circuit voltages. Be sure to remove all rings, watches, and other jewelry from fingers, wrists, and arms before removing panels and devices.



Note If the chassis has any empty slots, they are covered with blank panels when the Cisco ICS 7750 is shipped to you. Do not remove the panel covering an empty slot until you are ready to install a card in the slot.



Note You do not have to disassemble any system component or remove the chassis from the rack to perform any of the procedures described in this section.


Best Practices for Hot Swapping

You can hot swap cards while the Cisco ICS 7750 is operating. With hot swapping, you do not need to power down the system. However, be sure to read and follow the best practices in this section and in the "Best Practices for Card Replacement" section, and the specific instructions for removing and replacing each type of card or module before you hot swap it.


Warning Only trained and qualified (IP Telephony certified for the Cisco ICS 7750) personnel should be allowed to install or replace this equipment.



Caution When replacing a hot-swappable system card, you do not need to power down the entire chassis by using the chassis power supply switch or by unplugging the power supply. Powering down the entire chassis may cause the Cisco ICS 7750 to lose important configuration data and will interrupt any applications or functions running on other cards in the chassis. (The one exception to this is an electrical accident, in which case turning off the power is recommended; see the "Safety with Electricity" section.)


Caution You can install only one SAP and one SSP in a single Cisco ICS 7750 chassis. If you must hot swap the SAP, the cooling fans do not operate; the system's ability to detect alarms associated with the operating environment, fans, and power supply modules is degraded; and applications using the COM ports on the SAP lose their access to those ports, until an operational SAP is properly reinserted in the chassis. If you must hot swap the SSP, the system loses LAN connectivity, and calls being made from or to Cisco IP phones that are switched through that SSP are disconnected until an operational SSP is properly reinserted in the chassis.


Caution Depending on your system configuration, hot swapping of SPEs, ASIs, or MRPs can adversely affect users connected to the system.

For example, if Cisco CallManager is running on only one SPE, hot swapping that SPE disconnects calls to or from the PSTN and prevents the system from processing further PSTN traffic until an operational SPE is properly reinserted into the chassis. Similarly, hot swapping an ASI or MRP that is in the process of routing voice or WAN traffic prevents that traffic from reaching its destination. If you have a Flash-based MRP card configured as the only VLAN router and the MRP goes offline, all call processing might be lost (along with access to other IP devices). Disruption of call processing services may occur if the MRP is routing calls across VLANs. If fault tolerance is critical, you can use the Hot Standby Router Protocol (HSRP) for more reliable and redundant routing. For additional information about HSRP, refer to Hot Standby Router Protocol (HSRP) Features and Functionality.

Contact your Cisco sales representative for guidelines on installing cards and software on your system for maximum availability and redundancy.

Best Practices for Card Replacement

This section provides best practices for replacing system cards:

Best Practices for Resetting or Removing Cards

Best Practices for Inspecting the Chassis Backplane and Card Connectors Before Installing Cards

Best Practices for Installing Cards

Best Practices for Resetting or Removing Cards

Consult these guidelines (and the instructions in "Best Practices for Hot Swapping") before resetting or removing cards:

Check card LEDs before attempting to reset or remove a card.

Do not press the SHTDN button on any card in the Cisco ICS 7750 chassis unless you are directed to do so.


Caution Always use the extractor levers to disengage cards from the chassis. Failure to use the levers can cause system error messages that indicate a card failure. However, do not use the extractor levers to lift or support the weight of the cards.

Best Practices for Inspecting the Chassis Backplane and Card Connectors Before Installing Cards

Before you install a card, perform the following inspections:

Inspect the backplane for bent pins (see Figure 3) or bent dividers between rows.

If the backplane has bent pins, do not install a card in that slot. Installing a card into a damaged backplane slot will damage the connector on the card.

Figure 3 Backplane Inspection

Inspect the card for damaged holes on the connector (see Figure 4).

If the connector has damaged holes, do not install the card. Installing a card that has a damaged connector will damage the backplane. Return damaged cards to Cisco (see the "RMA Return Instructions" section).

Figure 4 Card Connector Inspection

Best Practices for Installing Cards

When installing cards, consult these guidelines, and follow the card-specific instructions:

Do not force the card faceplate into its slot. This action can damage the pins on the backplane if they are not aligned properly with the module or card.

Before installing a card, be sure to align its top and bottom edges with the upper and lower card guides in the chassis slot. Do not attempt to push the card into its slot until its top and bottom edges are in proper alignment.

When installing a card, carefully slide it all the way into the slot, and press both extractor levers inward (toward the center of the card) as far as they will go. The front of the card should now be flush with the other cards in the chassis. Using this method ensures that the card connector correctly mates with the backplane. For more information and an illustration on installing a card, see the "Installing an SPE" section.

If the card is particularly tight in its slot, or if the extractor lever engagement hooks are not engaging with the chassis, you might need to take the card out and insert it again to cause its extractor levers to engage properly.


Caution Do not push the card with so much force that it bends in the middle, since bending a card might force its sensitive electronic components to come in contact with adjacent cards.

The card or module should be firmly seated in the slot. Any card or module that is only partially connected to the backplane can disrupt system operation.

After card installation is complete, always use the lock-down screws (at the top and bottom of the card) to secure the card firmly in place in the chassis. If the screws do not engage, the extractor levers are not properly aligned, and the card is not firmly seated in the chassis. Remove and reinsert the card until you can fully tighten the screws.

Removing and Replacing SPE310s

This section describes how to determine the function of an SPE, tells how to install and replace SPEs, and contains the following subsections:

Accessing the SPE310

Removing an SPE

Installing an SPE

Verifying SPE Installation

Configuring a New or Replacement SPE

Downgrading ICS System Software


Note This document is not intended for use with SPE200s. If you need assistance with an SPE200, contact the Cisco Technical Assistance Center (see the "Technical Assistance Center" section).


Accessing the SPE310

You can access the SPE310 Windows interface to determine whether the SPE is running ICS System Software or ICS Core Software. The SPE310 Windows interface can be accessed in either of the following ways:

Accessing the SPE310 Windows Interface Through Terminal Services Client

Accessing the SPE310 Windows Interface Through Directly Connected Peripherals

Refer to Chapter 5, "Operating the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide for more information on accessing the SPE310 Windows interface through Terminal Services Client or through directly connected peripherals.

Accessing the SPE310 Windows Interface Through Terminal Services Client

To access the SPE310 Windows interface through Terminal Services Client, follow these steps:


Step 1 On the PC that you use to administer the Cisco ICS 7750, choose Start > Programs > Terminal Services Client > Client Connection Manager.

Step 2 Use the Client Connection Manager to open a Terminal Services connection with the target SPE:

If you already have a Terminal Services Client connection defined for the target SPE, choose it, and choose File > Connect.

If you do not have a Terminal Services Client connection defined for the target SPE, choose File > New Connection, and follow the instructions in the wizard, and then choose File > Connect.

The Terminal Services Client window opens. You can use Terminal Services Client to access standard Windows utilities on the SPE310, such as Windows Explorer and the Control Panel.



Note You cannot perform a full installation of ICS System Manager (including Microsoft SQL Server software) over Terminal Services Client. You must access the SPE310 through directly connected peripherals to install ICS System Manager. You can install ICS Core Software over Terminal Services Client.


Accessing the SPE310 Windows Interface Through Directly Connected Peripherals

You can connect a monitor, keyboard, and mouse directly to the SPE310 to access the Windows user interface, as follows:


Step 1 Connect the monitor cable to the video port on the SPE310, and power on the monitor.

Step 2 Do one of the following, based on the type of peripherals that you are using:

USB—Connect a USB keyboard to one SPE310 USB port, and connect a USB mouse to the other SPE310 USB port.

PS/2—Connect the "Y" splitter cable for your keyboard and mouse to the keyboard/mouse port on the target SPE310. Then connect your keyboard and mouse to the available ends of the "Y" splitter cable.


Note If you are using the "Y" splitter cable to connect a PS/2 mouse and a keyboard to the SPE310, the keyboard and mouse must be connected at or before the time that the SPE310 is rebooted in order to be recognized by the operating system. A USB keyboard and mouse are usually recognized without rebooting the operating system.




Note For a summary of the issues related to the connection of peripherals to SPE310s, as well as best practices for using peripherals with SPE310s, refer to the "Using Peripherals with SPE310s" section in Chapter 5, "Operating the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide.


Installing Microsoft Terminal Services Client

If Microsoft Terminal Services Client is not installed on your PC, complete the following steps:


Step 1 Open Netscape Communicator or Microsoft Internet Explorer.

Step 2 In the Location or Address field, enter the following URL:

http://www.microsoft.com/windows2000/downloads/recommended/TSAC/tsmsi.asp

Step 3 Follow the instructions to download and install Microsoft Terminal Services Client.


Determining the Function of an SPE

Follow these steps to use ICS System Manager to determine whether the SPE installed in the chassis is running ICS Core Software or ICS System Manager software:


Step 1 On a PC connected to the Cisco ICS 7750 or on the SPE running System Manager, launch a web browser, and access ICS System Manager by entering the following in the address field:

http://SPE IP address/ics

where SPE IP address is the IP address of the SPE running System Manager.

The ICS System Manager screen appears in the browser window, and you are prompted for a user ID and password.

Step 2 In the User ID field, enter admin.

Step 3 In the Password field, enter the ICS super admin password (set during ICSConfig).

Step 4 Click Login.

Step 5 Examine the displays provided in ICS System Manager to determine the function of each card in the chassis. For example:

ICS System Manager: V3.2.8

or

ICS Core Software: V3.2.8

Step 6 Exit ICS System Manager when you have finished.


Removing an SPE

This section explains how to remove SPEs. Figure 5 shows how to remove a card.

Figure 5 Removing Cards from the Cisco ICS 7750 Chassis

You do not have to turn off the power for these procedures.


Caution When replacing an SPE, do not power down the entire chassis by using the chassis power supply switch or by unplugging the power supply. Powering down the entire chassis may cause the Cisco ICS 7750 to lose important configuration data and will interrupt any applications or functions running on other cards in the chassis.


Note Powering down an SPE will interrupt any services or applications running on that SPE. Measures should be taken to minimize impact on users.



Note If you have a chassis with more than one SPE installed and if you are not certain which SPE is running System Manager and which card or cards are running other applications, you can use ICS System Manager to check. See the "Determining the Function of an SPE" section.


Complete the following steps to remove an SPE:


Step 1 Press the SHTDN button on the card that you want to remove.


Note If the SPE to be removed is already shut down, this step is unnecessary, and you can proceed to Step 2.


The STATUS LED on the card starts blinking; after several minutes, it turns off. Wait for the STATUS LED to turn off before continuing.

Step 2 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle cards by the edges only, and use an ESD-preventive wrist strap or other grounding device.

Step 3 For the SPE that you wish to remove, completely loosen the lock-down screws (at the top and bottom of the card).

Step 4 Press the upper and lower extractor levers outward (away from the center of the card) at the same time to disengage the card from the backplane. Pull the card out only far enough (about 1 inch) to disengage from the backplane; do not completely remove the card from the chassis.


Caution Always use the extractor levers to disengage or seat cards. Failure to use the levers can cause system error messages that indicate a card failure. Do not use the extractor levers to lift or support the weight of the cards.


Note Unseating or removal of the SPE should be done only when the SPE has been safely shut down. In normal use, you should not unseat or remove an SPE without first ensuring that the SPE has been shut down.



Warning High performance devices on system cards can get hot during operation. To remove a card, hold it by the faceplate and bottom edge. Allow the card to cool before touching any other part of it or placing it an anti-static bag.


Step 5 Grasp the extractor levers, and gently pull the card partially out of the chassis slot until you can grasp the card front panel with one hand. Place your other hand under the card to balance the weight of the card as you prepare to pull it out of the slot.

Step 6 Pull the card straight out of the slot. Avoid touching the circuitry or any connector pins.

Step 7 Place the card on an antistatic mat or foam pad until you are ready to reinstall it in the chassis. If you plan to return the card to the factory, place it inside an antistatic bag, and see the "RMA Return Instructions" section.

Step 8 Repeat Step 1 through Step 7 as needed to remove additional SPEs.


Installing an SPE

This section explains how to install SPEs. Figure 6 shows how to install a card.


Note If you have configured VLAN usage on the Cisco ICS 7750, system cards cannot be moved around in the chassis without first reconfiguring the switchport definition on the SSP. To avoid reconfiguration, make sure that you install the replacement SPE into the same slot in the chassis from which the original SPE was removed.


Figure 6 Installing Cards in the Cisco ICS 7750 Chassis

You do not need to power down the entire chassis for these procedures.


Caution When installing cards, be sure to apply equal amounts of pressure to the top and bottom of the card. You can damage the card and the chassis backplane if you apply too much pressure to either the top or the bottom of the card.

Follow these steps to install an SPE:


Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle cards by the edges only, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Align the SPE with the upper and lower card guides in an available chassis slot, and make sure that the extractor levers are in the open position (pointing up and down).

Step 3 With the top and bottom edges of the card in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force that you use to get the card past the grounding clips. If you encounter extreme resistance, pull the card out slightly and push it back in again.

Step 4 Press the upper and lower extractor levers inward (toward the center of the card) at the same time until they lock into their slots. This step firmly seats the SPE into the chassis.

Step 5 Fasten the lock-down screws for the SPE, securing it in the chassis.

Step 6 Verify the installation (see the "Verifying SPE Installation" section).


Verifying SPE Installation

This section explains how to verify an SPE installation.

To verify that the SPE is operating correctly, check that its STATUS LED is functioning as follows:

The STATUS LED blinks green when the power-on self-test (POST) is in process or the card is shutting down.

The STATUS LED is green when the POST is complete, card initialization is complete, and the card is operating correctly.

The STATUS LED is off when the shutdown process is complete (indicates that the card can be removed from the chassis or that power is off for the entire Cisco ICS 7750).


Note The ALARM LED on Cisco ICS 7750 cards turns yellow during the POST. If the ALARM LED on any card does not turn off upon completion of the POST, that card is not functioning correctly. For general information on solving problems with cards, refer to Chapter 3, "Solving Hardware Problems," in the Cisco ICS 7750 Troubleshooting Guide.


Configuring a New or Replacement SPE

This section provides the procedures for configuring a new or replacement SPE after the SPE is installed. This section contains the following subsections:

SPE Installation and Replacement Scenarios

Installing a New SPE for Applications

Replacing an Existing SPE for Applications

Replacing the SPE Running System Manager


Note Because all system cards in the Cisco ICS 7750 chassis must be on the management VLAN (VLAN 1) when using VLAN functionality, the SPE on which Cisco CallManager is running must also be on VLAN 1. Cisco CallManager will not function properly if the SPE on which it is running has been configured for multiple subinterfaces.



Note The SPE and the MRP200 cards are designated as endpoints when using VLAN support on the Cisco ICS 7750; no VLAN configuration is required on these cards. However, switchport definitions might need to be configured on the SSP for the SPE or the MRP200. See the "Configuring VLAN Support" section.


SPE Installation and Replacement Scenarios

This section describes the scenarios in which SPE installation and/or replacement might be required:

Installing a new SPE for applications—In this instance, you already have a functioning SPE running System Manager in the Cisco ICS 7750 chassis, and you might have one or more existing SPEs for applications. The goal, as identified in this scenario, is to add another SPE and set it up so that it can have applications installed on it. (See the "Installing a New SPE for Applications" section.)

Replacing an existing SPE for applications—In this case, you have an SPE for applications already installed in the chassis, but you wish to replace this SPE with a new one. Here, you might also want to migrate saved configuration data and settings to the new SPE once it is in place and operational. (This scenario includes the assumption that a successful backup was completed for the previously installed applications.) In this scenario, the existing SPE running System Manager and any other installed SPEs are left intact and unchanged. (See the "Replacing an Existing SPE for Applications" section.)

Replacing the SPE running System Manager—This is a more complex scenario, and it requires the greatest number of steps to complete. In addition, although adding or replacing an SPE for applications can be done while the chassis is running, with minimal impact on users and services, replacing the SPE running System Manager takes more time and might require temporary interruption of services. For this reason, replacing the SPE running System Manager is best done at a time when interruption of service will have minimal impact, such as during scheduled maintenance. (See the "Replacing the SPE Running System Manager" section.)

The following sections will address each of these scenarios. You need to follow only the instructions in the scenario that applies to your situation.


Note Because there can be only one SPE running System Manager in a chassis, system software and any application data must be backed up (if possible) before removing the original SPE running System Manager.



Note The procedures and steps for installing specific applications (such as Cisco CallManager) are beyond the scope of this document. For information on how to install, configure, back up, and restore Cisco ICS 7750-compatible applications, refer to the user documentation for those applications. If you still need assistance, see the "Obtaining Technical Assistance" section.



Tip To reduce chances for error and other conditions which could result in lengthy interruption of Cisco ICS 7750 services, it is recommended that you attempt to install or replace only one SPE in a chassis at a time. If you need to perform this operation for more than one SPE in a chassis, complete the entire installation or replacement process for a single SPE, and verify that is functioning properly, before installing or replacing the next SPE. In such a situation, always replace the SPE running System Manager first (if it is one of the SPEs that need to be replaced).


Installing a New SPE for Applications

The procedures in this section apply to installing a new additional SPE in a Cisco ICS 7750 chassis. This assumes that the new additional SPE was shipped from Manufacturing, and as such, has the applicable ICS software installed. These procedures do not apply to replacing an existing SPE for applications or to replacing the SPE running System Manager.


Note To replace an existing SPE for applications, see the "Replacing an Existing SPE for Applications" section. To replace the SPE running System Manager, see the "Replacing the SPE Running System Manager" section.


To install the new SPE for use as an additional SPE that runs applications, insert the SPE into an empty slot in the Cisco ICS 7750 chassis, following the instructions detailed in the "Installing an SPE" section.


Note After you install the SPE in the chassis, wait several minutes before you begin configuring the new SPE, so that the Windows 2000 operating system can finish booting. If you start ICSConfig before Windows 2000 is running, the new SPE will not be discovered, resulting in an error condition.


After you have installed the new SPE into the chassis, you can proceed to the "Using ICSConfig to Configure the New SPE for Applications" section.

If you have configured VLAN functionality, see the "Configuring VLAN Support" section.

After you have installed and configured the SPE, you can continue with the "Installing Applications" section.

Using ICSConfig to Configure the New SPE for Applications

To configure the new SPE for applications, follow these steps:


Step 1 On a PC with network connectivity to the Cisco ICS 7750 or on the SPE running System Manager, launch a web browser.

Step 2 Enter the following URL:

http://SPE IP address/icsconfig/

where SPE IP address is the IP address of the SPE running System Manager.

Step 3 Log in as administrator, using the user ID administrator and the current password (the default is changeme).

Step 4 Click ICS 7700 System Setup.

Step 5 Make any necessary changes to the configuration screens. (Refer to the Cisco ICS 7750 Installation and Configuration Guide for instructions.) Make a note of the IP address of the new SPE. Go to Step 6 to see the changes.

Step 6 When you have configured the necessary settings, the Summary page displays a list of all the configuration pages and the data entered in each field.

All of the page names listed on the Summary page are links to the configuration pages, where you can change any information that you entered. To change any of the settings, click the associated hyperlinked page. When the settings are correct, click Next to continue to the Ready to Submit page.

The Ready to Submit page provides instructions on what to do after you submit the changes to the Cisco ICS 7750. Submitting and processing these changes can take up to 20 minutes.

Step 7 Click Submit.


Caution After clicking Submit, do not reboot your Cisco ICS 7750 or perform any configuration tasks on the Cisco ICS 7750 until this process has completed.

Step 8 Verify that the SPE is functioning correctly (see the "Verifying Card Installation" section).


Configuring VLAN Support

If you have configured VLAN functionality on the Cisco ICS 7750, you must configure the internal ports on the SSP (Fast Ethernet 0/3 through Fast Ethernet 0/8) as "static access vlan 1" or "trunking native vlan 1," depending on the type of card that is installed in the chassis slot.

Follow these steps to configure the interface for the SPE on the SSP:


Step 1 The interface for the SPE (in the slot in which the SPE is connected) must be configured as "static access vlan 1." (This is the default setting on a new SSP, and it might not need to be configured.)

For example, if the SPE is installed in slot 5, the configuration on the SSP would look as follows:

Switch#configure terminal
Switch(config)#int fastEthernet 0/7
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 1

Step 2 If you want to define Class of Service (CoS), set layer 2 CoS to 5 for all packets leaving from this port:

Switch(config)#int fastEthernet 0/7
Switch(config-if)#switchport priority default 5



Note The internal port of the SSP which connects to the SPE or to the MRP200 must be defined as "static access vlan 1." This is the default setting on a new SSP, and might not need to be configured.

The internal port of the SSP which connects to the Flash-based MRP (which would be part of multiple VLANs) must be configured as "dot1q trunk native vlan 1." See the "Configuring VLAN Support on the SSP" section. If the Flash-based MRP is not acting as a VLAN router, you can configure the internal port of the SSP as "static access vlan 1."


For detailed information about configuring VLANs and VLAN support on the Cisco ICS 7750, refer to the Cisco ICS 7750 Installation and Configuration Guide.

Installing Applications

For information on how to install and configure applications on the newly installed SPE, refer to the documentation for the applications.


Caution If you are upgrading system software on an SPE running Cisco Unity, you may need to manually stop some of the services that are running on the Cisco Unity SPE before you can perform the upgrade. Refer to the Release Notes for System Software Release 2.4.0 on the Cisco ICS 7750 for detailed steps to follow to complete the Cisco Unity upgrade.

Replacing an Existing SPE for Applications

The procedures described in this section apply to replacing (or swapping) an existing SPE that is running applications only (not the SPE running System Manager). In this scenario, you remove an SPE for applications and replace it with a new SPE intended to perform the same functions as the previous SPE.


Note To install an additional SPE for applications, see the "Installing a New SPE for Applications" section. To replace the SPE running System Manager, see the "Replacing the SPE Running System Manager" section.


To replace an SPE for running applications that is already installed in a Cisco  ICS 7750 chassis, you need to complete the following procedures in order:

1. Back up configuration data and settings for the original SPE for applications (if application backup functions are available). See the "Backing Up Application Software Data" section.

2. Shut down and remove the SPE that is to be replaced. See the "Shutting Down and Removing the SPE for Applications" section.

3. Insert and power up the new SPE in the same or a different chassis slot. The new SPE should have system software installed; if you need to obtain a new copy of system software, see the "Required Tools and Equipment" section. If you have configured VLAN usage on your system, it is preferable to install the replacement SPE in the same chassis slot from which the original SPE was removed. See the "Installing the Replacement SPE for Applications" section.

4. Set the host name for the SPE. See the "Setting the Host Name on the Replacement SPE" section.

5. Use ICSConfig to configure the SPE. See the "Using ICSConfig to Configure the Replacement SPE for Applications" section.

6. Install applications and restore application configuration data and settings (if available). See the "Installing Applications and Restoring Saved Application Data" section.

The following sections provide detailed procedures.

Backing Up Application Software Data

For information on how to back up application data on an existing SPE, refer to the documentation for each application. Note that not all applications have built-in backup and restore features; in those cases, you need to back up and restore the application data manually.

If you do plan to restore backed up application data, you should also record the IP address and host name of the SPE being replaced. Later, during the configuration phase of setting up the SPE for applications, you will be directed to rename the SPE to match the host name of the card you removed.

To locate the SPE host name, follow these steps:


Step 1 Connect a monitor cable to the video port on the SPE310, and power on the monitor.

Step 2 Do one of the following, based on the type of peripherals you are using:

USB—Connect a USB keyboard to one SPE USB port, and connect a USB mouse to the other SPE USB port.

PS/2—Connect the "Y" splitter cable for your keyboard and mouse to the keyboard/mouse port on the target SPE, and then connect your keyboard and mouse to the available ends of the "Y" splitter cable.


Note If you are using the "Y" splitter cable to connect a PS/2 mouse and a keyboard to the SPE, the keyboard and mouse must be connected at or before the time that the SPE is restarted in order to be recognized by the operating system. This is not the case with a USB keyboard and mouse, which typically are recognized without restarting the operating system.



Note For a list of USB peripherals that have been tested on the Cisco ICS 7750, refer to the "Connecting a Monitor, Keyboard, and Mouse to the SPE Card" section in the
Cisco ICS 7750 Installation and Configuration Guide.


Step 3 Log in as an administrator (user ID administrator), and enter your password (the default is changeme).

Step 4 On the SPE, use either the Command Prompt (DOS) window or the Windows System Properties dialog box to find the host name. To use the Command Prompt window, go to Step 5. To use the System Properties dialog box, go to Step 7.

Step 5 Choose Start > Programs > Accessories > Command Prompt.

Step 6 Enter the hostname command. The SPE host name appears. Record the host name and skip the rest of this procedure.

Step 7 Choose Start > Settings > Control Panel > System.

Step 8 In the System Properties dialog box, under the Network Identification tab, click Properties.

Step 9 In the Identification Changes dialog box, the Computer Name field displays the host name. Record this information.

Step 10 Click Cancel to close the Identification Changes dialog box, and close the System Properties dialog box.


After you have recorded the SPE host name and backed up the application software data, you can continue with the "Shutting Down and Removing the SPE for Applications" section.

Shutting Down and Removing the SPE for Applications

To shut down and remove the old SPE, follow the instructions detailed in the "Removing an SPE" section.

After you have removed the old SPE for running applications, you can continue with the "Installing the Replacement SPE for Applications" section.

Installing the Replacement SPE for Applications

To install the replacement SPE for applications, insert the SPE into the same chassis slot from which you removed the old SPE for applications. Follow the instructions in the "Installing an SPE" section.

After you have installed the SPE in the chassis, you can continue with the "Setting the Host Name on the Replacement SPE" section.


Note If the slot for the replacement SPE is not the original slot from which you removed the SPE, and if a COM port was assigned for that SPE, you must reconfigure the COM ports (using ICS System Manager) to map the SPE to the new location. ICS System Manager does not automatically track this change. For information on how to reconfigure the COM port assignment, refer to the ICS System Manager online help.



Note If you have configured VLAN usage on the Cisco ICS 7750, system cards cannot be moved around in the chassis without first reconfiguring their switchport definitions on the SSP. To avoid reconfiguration, make sure that you install the replacement SPE into the same slot in the chassis from which the original SPE was removed.


Setting the Host Name on the Replacement SPE

If you have backed up application software data that can be restored only to an SPE having the same host name, use the following procedure to change the host name. (This is the case, for instance, with Cisco CallManager backups.)

You do not need to set the date and time on the SPE running core software because the SPE running System Manager will set this information when it discovers the SPE.

To change the host name on the SPE, follow these steps:


Step 1 Connect your peripherals as described in the "Backing Up Application Software Data" section.

Step 2 Log in as an administrator (user ID administrator), and enter your password (the default is changeme).

Step 3 If you have backed up application data that can be restored only to an SPE by using the same host name, proceed to the next step. If no host name change is required, skip the remaining steps, and continue with the "Using ICSConfig to Configure the Replacement SPE for Applications" section.

Step 4 In the Control Panel, double-click System to open System Properties.

Step 5 In the System Properties dialog box, under the Network Identification tab, click Properties.

Step 6 In the Identification Changes dialog box, in the Computer Name field, enter the host name (maximum of 15 characters) you originally had for the SPE you removed, and click OK.

Step 7 Click OK to close the System Properties dialog box.

Step 8 You are prompted to reboot the system. Click OK to reboot the SPE, implementing the host name change.


After you have completed the SPE host name change, continue with the "Using ICSConfig to Configure the Replacement SPE for Applications" section.

Using ICSConfig to Configure the Replacement SPE for Applications

To configure the SPE, using ICSConfig, complete the following steps:


Step 1 On a PC connected to the Cisco ICS 7750 or on the SPE running System Manager, launch a web browser.

Step 2 Enter the following URL:

http://SPE IP address/icsconfig/

where the address entered is the IP address of the SPE running System Manager.

Step 3 Log in as administrator (using the user ID administrator and the default password changeme).

Step 4 Click ICS 7700 System Setup.

Step 5 Make any necessary changes to the configuration screens, ensuring that the new SPE has the same IP address as the IP address of the SPE that was replaced. Refer to the Cisco ICS 7750 Installation and Configuration Guide for instructions. Go to Step 6 to see changes made to the configuration.

Step 6 When you have configured the necessary settings, the Summary page displays a list of all the configuration pages and the data entered in each field.

All the page names listed on the Summary page are links to the configuration pages, where you can change any information that you entered. To change any of the settings, click the associated hyperlinked page. When all the settings are correct, click Next to continue to the Ready to Submit page.

The Ready to Submit page provides instructions on what to do after you submit the changes to your Cisco ICS 7750. Submitting and processing these changes can take up to 20 minutes to complete.

Step 7 Click Submit.


Caution After clicking Submit, do not reboot your Cisco ICS 7750 or perform any configuration tasks on the system during this process.

Step 8 Verify that the SPE is functioning correctly (see the "Verifying Card Installation" section).


If you have configured VLAN functionality, check the configuration on the SSP, and configure CoS. See the "Configuring VLAN Support" section.

After the SPE is installed and configured, you can proceed to the "Installing Applications and Restoring Saved Application Data" section.

Installing Applications and Restoring Saved Application Data

For information on how to install and configure applications on the newly installed SPE, refer to the documentation for the applications. Similarly, for details on how to restore saved or backed-up application data, where such functions are available, see the application documentation.


Caution If you are upgrading system software on an SPE running Cisco Unity, you may need to manually stop some of the services that are running on the Cisco Unity SPE before you can perform the upgrade. Refer to the Release Notes for System Software Release 2.4.0 on the Cisco ICS 7750 for detailed steps to follow to complete the Cisco Unity upgrade.

Replacing the SPE Running System Manager

In this scenario, you replace the SPE running System Manager with a new SPE.


Note The Cisco ICS 7750 supports the operation of only one SPE running System Manager in a chassis. For this reason, the process requires that you back up system software and any application data on the original SPE running System Manager before you install and restore data to the new SPE.



Note The Cisco ICS 7750 services will be interrupted briefly during this process. It is therefore recommended that you replace the SPE running System Manager at a time when impact to users will be minimized, such as during scheduled maintenance or outside normal business hours.


Perform the following procedures, in order, to replace the SPE running System Manager:

1. Back up system data on the original SPE running System Manager. See the "Backing Up System Software Data" section.

2. If there are any applications installed on the SPE that support backup functionality, back up the application data and settings. See the "Backing Up Application Data" section.

3. Shut down and remove the original SPE to be replaced. See the "Shutting Down and Removing the SPE Running System Manager" section.

4. Insert the SPE into the same (now empty) chassis slot from which you removed the original SPE running System Manager. See the "Installing an SPE" section.

5. Remove the factory-installed ICS Core Software and install the ICS System Manager Software. See the "Converting the ICS Core Software to ICS System Manager Software" section.

6. Use ICSConfig to configure or verify the settings of the new ICS System Manager. See the "Using ICSConfig to Configure and Verify the SPE Running System Manager" section.

7. Access ICS System Manager, and restore the functionality of the system. See the "Accessing ICS System Manager and Restoring Cisco ICS 7750 Functionality" section.

8. (Optional) Install applications, and restore application configuration data and settings (if available). See the "Installing Applications and Restoring Saved Application Software Data" section.

The following sections provide detailed procedures.

Backing Up System Software Data

Before replacing the SPE running System Manager, you should always create a backup of the system software configuration, if possible. This system backup will include SPE registry settings, ICS System Manager database records, and IOS configuration files for ASIs and MRPs.

If you do not have a valid backup, you will need to configure the new SPE running System Manager as if it were a new Cisco ICS 7750 chassis installation, a process which takes a considerably longer time to complete. See the Cisco ICS 7750 Installation and Configuration Guide for information and procedures on how to do this.

For instructions on how to back up system software data, refer to the "Backing Up System Data" section in Chapter 5, "Operating the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide. Be sure to back up to a hard disk location other than on the SPE that you are removing, and make sure that there is enough disk space for the backup (approximately 75 MB).


Caution Before you back up system data, make sure that no two devices (such as Cisco IP phones) are assigned the same IP address. If any two devices are using the same IP address, you might experience problems if you later attempt to restore from this backup.


Note COM port assignment information is not stored in the ICS System Manager database and is not included when you perform a backup. You may need to reconfigure the COM port assignment after you restore the ICS System Manager data.


You should also record the host name for the SPE running System Manager that is being replaced. Later, during the configuration phase of setting up the new SPE, you will be directed to rename the SPE to match the host name of the card you removed.

To locate the SPE host name, follow these steps:


Step 1 Connect your peripherals as described in the "Backing Up Application Software Data" section.

Step 2 Log in as an administrator (user ID administrator), and enter your password (the default is changeme).

Step 3 On the SPE, use either the Command Prompt (DOS) window or the Windows System Properties dialog box to find the host name. To use the Command Prompt window, go to Step 4. To use the System Properties dialog box, go to Step 6.

Step 4 To open the Command Prompt window, choose Start > Programs > Accessories > Command Prompt.

Step 5 Enter the hostname command. The SPE host name appears. Record the host name, and skip the rest of this procedure.

Step 6 To access the System Properties dialog box, choose Start > Settings > Control Panel > System.

Step 7 In the System Properties dialog box, under the Network Identification tab, click Properties.

Step 8 In the Identification Changes dialog box, the Computer Name field displays the host name. Record this information.

Step 9 Click Cancel to close the Identification Changes dialog box, and close the System Properties dialog box.


Backing Up Application Data

Backing up applications that may have been installed on the SPE running System Manager is a separate, secondary operation. For information on how to back up application data on an existing SPE, refer to the documentation for each application. When applications do not have backup and restore features, you will need to back up and restore the application data manually.

After you have backed up the system, you can continue with the "Shutting Down and Removing the SPE Running System Manager" section.

Shutting Down and Removing the SPE Running System Manager

To shut down and remove the old SPE running System Manager, follow the instructions detailed in the "Removing an SPE" section.

After shutting down and removing the original SPE running System Manager, continue with "Installing the Replacement SPE Running System Manager" section.

Installing the Replacement SPE Running System Manager

To install the replacement SPE running System Manager, insert the SPE into the same (now empty) chassis slot from which you removed the original SPE running System Manager. To do this, follow the instructions in the "Installing an SPE" section.

After the SPE has been installed in the chassis, go to the "Converting the ICS Core Software to ICS System Manager Software" section.


Note If the slot for the replacement SPE is different from the original slot from which you removed the SPE, and if there was a COM port assigned for that SPE, you must reconfigure the COM ports (using ICS System Manager) to map the SPE to the new location. ICS System Manager does not automatically track this change. For information on how to reconfigure the COM port assignment, refer to the ICS System Manager online help.



Note If you have configured VLAN usage on the Cisco ICS 7750, system cards cannot be moved around in the chassis without first reconfiguring their switchport definitions on the SSP. To avoid reconfiguration, make sure that you install the replacement SPE into the same slot in the chassis from which the original SPE was removed.


Converting the ICS Core Software to ICS System Manager Software

Follow these steps to convert the ICS Core Software to ICS System Manager Software on the SPE.


Step 1 Access the SPE310 Windows user interface. Connect your peripherals as described in the "Accessing the SPE310 Windows Interface Through Directly Connected Peripherals" section.

Step 2 Log in as an administrator (user ID administrator), and enter the default password changeme. Do not change the default password.


Caution It is strongly recommended that you close all open programs before installing this software.

Step 3 On the target SPE, use Windows Explorer to navigate to c:\ICS_Full_2.x.x

where 2.x.x is the version of ICS System Software to be installed.

Step 4 Double-click the Setup.exe file in the directory.

The Setup window appears and displays a message that the system is being checked.


Note The conversion setup program must be run using the full ICS System Software installation package (CD or CCO version). Conversion is not available if you are using the upgrade-only package.



Note Because the conversion setup program installs Microsoft SQL Server, it must be run locally on the target SPE. The setup program cannot be run over a Terminal Services Client connection.


Step 5 In the Welcome window, click Next to continue the setup.

Step 6 In the Hostname field, in the Change Hostname window, enter the host name that you originally assigned to the SPE that you removed.

Changing the host name is subject to the following restrictions:

The host name must be unique to your network.

The host name must not be longer than 15 characters.

The host name cannot have a space anywhere in the host name, including leading or trailing spaces. The following characters and symbols are not valid entries in host names: \ " / [ ] : | < > + = ; , ?.


Note Because Microsoft SQL Server is installed on the SPE as part of the system software and later as part of the Cisco CallManager installation, it is best practice to change the SPE host name before installing system software. If you have already installed system software, you can still change the host name of an SPE running System Manager, but only if no applications (including Cisco CallManager) have been installed on the SPE. For detailed procedures on how to change the host name of an SPE running System Manager, refer to the "Changing the Host Name of the SPE310 Running System Manager" section in Chapter 5, "Operating the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide. After any applications have been installed on the SPE, you cannot change the host name without first reimaging the SPE and restarting the SPE replacement process.


Step 7 Click Next.

Step 8 In the Date & Time window, change the date, time, and time zone for the SPE, if necessary. If daylight savings time is practiced in the selected time zone, you have the option of setting the SPE to automatically adjust the time for daylight savings time changes. Click Next.

Step 9 In the Select Upgrade Type window, click the Convert ICS Core Software to ICS System Manager Software radio button.

Step 10 Click Yes to continue with the setup installation.


Caution Do not install ICS System Manager on an SPE running Cisco Unity Voice Messaging.

The Confirmation window appears. In this window, you can review the installation details and confirm that they are correct.

Step 11 In the Confirmation window, click Next to confirm the installation details and to proceed with the installation.

Step 12 In the Setup window, click Next to install the ICS System Manager software package.


Note There must be one (and only one) SPE310 running ICS System Manager software in the chassis.


If you changed the host name of the SPE as described in Step 6, the SPE will restart.

After the SPE has restarted, the Setup Status window displays an installation task list.

During the Windows 2000 setup, the ICS System Software setup program checks for the installation of hotfixes. If any applicable hotfixes have not been installed on the system, the ICS System Software setup program will install the hotfixes and restart the SPE. Setup will then continue to install the remaining tasks.

Upon completion, the Setup window displays a message about the IOS images being imported into the software image library.

Step 13 In the Setup Status window, installation information and information about the location of log files are displayed. Click Next.

Step 14 In the Instructions window, click Finish to complete the ICS System Software setup.

ICSConfig launches automatically. The Cisco ICS 7700 System Manager Initial Setup window appears, containing the Cisco End User License Agreement.

Step 15 Read the Cisco End User License Agreement. Click I Accept.

Step 16 Click Continue.

Discovery of the system cards begins. You can monitor the progress by watching the percentage display at the top status bar on the attached monitor. When the card discovery process is finished, the ICS System Manager Initial Setup window appears.

Step 17 In the Initial Setup window, click OK to continue.

The ICS Replacement SPE setup window appears.

Step 18 In the ICS Replacement SPE setup window, assign the IP addresses for the system cards. For more information on using ICSConfig, refer to the ICSConfig online help and the "Launching the Configuration Program" section in Chapter 4, "Completing the Cisco ICS 7750 Installation," in the Cisco ICS 7750 Installation and Configuration Guide.


Note If you are installing a new SPE in the chassis, use an IP address not already assigned to another card in the chassis.


Use the system default (changeme) for all passwords unless you have previously changed the password. To move back and forth between the different configuration pages of ICSConfig, click the Back and Next buttons.

Step 19 After you have made all the changes, click Submit to deliver the values entered to the system.

The Replacement SPE window displays a message that the system configuration delivery is complete.

Step 20 Use one of the following options to configure the system:

To access ICSConfig to configure the system, double-click the URL shown in the Replacement SPE window.

To restore backed up System Manager data and settings, double-click the URL shown in the Replacement SPE window to view the procedures, or refer to the "Restoring System Data to the SPE310 Running System Manager" section in Chapter 8, "Maintaining the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide.


Note At the end of the restore process, you will be instructed to seat all the MRPs and ASIs. It can take up to 4 minutes per card to configure each MRP200, ASI81, or ASI160 and for TFTP to execute fully when first booting these cards in a chassis with a new SPE running System Manager. The Flash-based MRP cards (MRP300, MRP3-8FXS, and MRP3-16FXS) may boot in less time.


Step 21 At this point, any SPEs for applications (with the ICS Core Software installed) that may have been unseated should be seated as well.

Step 22 Perform the necessary Cisco IOS configuration for each MRP or ASI in the chassis. For more information, refer to Chapter 6, "Configuring the Cisco ICS 7750," in the Cisco ICS 7750 Installation and Configuration Guide.


After the SPE running System Manager has been configured and the system software has been restored (assuming that a system software backup is available), continue with the "Using ICSConfig to Configure and Verify the SPE Running System Manager" section. If you are using an external PC, continue with the "Configuring Your PC IP Address" section.

Configuring Your PC IP Address

If you are using a PC connected to the Cisco ICS 7750 and the IP address or subnet of the SPE running System Manager was changed as part of the restore, change the IP address of the PC connected to the chassis to the match the IP subnet of the SPE. You can do this manually in Network Settings or, if your network supports it, by reenabling DHCP address resolution on the PC.

Follow these steps to change the IP address on the PC connected to the Cisco ICS 7750:


Step 1 On the PC Desktop, right-click Network Neighborhood (Windows NT) or My Network Places (Windows 2000).

Step 2 Choose Properties.

Step 3 Click the Protocols tab (Windows NT), or right-click Local Area Connection and choose Properties (Windows 2000).

Step 4 Choose TCP/IP Protocol (Windows NT) or Internet Protocol (TCP/IP) (Windows 2000).

Step 5 Click Properties.

Step 6 Click the Specify an IP address radio button (Windows NT) or the Use the following IP address radio button (Windows 2000).

Step 7 In the IP Address field, enter a unique (unused) IP address, such as 10.0.0.250. (By default, system cards are assigned IP addresses in the range beginning with 10.0.0.1 and ending with 10.0.0.127.)

This IP address must meet the following requirements:

It must be in the same subnet as the cards in the Cisco ICS 7750.

It must not fall within the range of contiguous IP addresses that you have reserved for the Cisco ICS 7750 cards.

Step 8 In the Subnet Mask field, enter 255.255.255.0 (if you are using 24 bits of subnetting).

Step 9 Click OK.

Step 10 If a message appears which indicates that your PC must be rebooted to apply the changes, click Yes.

For additional information, refer to Chapter 4, "Completing the Cisco ICS 7750 Installation," in the Cisco ICS 7750 Installation and Configuration Guide.

After the SPE running System Manager has been configured and the system software has been restored (assuming that a system software backup is available), continue with the "Using ICSConfig to Configure and Verify the SPE Running System Manager" section.

Configuring Your Web Browser for System Manager

ICSConfig is a web-browser-based configuration program. To use ICSConfig on the SPE running System Manager, configure your web browser as follows:


Note To access the Cisco ICS System Manager, your browser must be configured as described before you can use the System Manager. Netscape Communicator 4.7 and Internet Explorer 5.5 are the only supported browsers.


Netscape Communicator 4.7

If you are using Netscape Communicator 4.7 on a PC connected to the Cisco ICS 7750, follow these steps to configure it to work with System Manager:


Step 1 Open Netscape Communicator.

Step 2 Choose Edit > Preferences.

Step 3 In the Preferences window, click Advanced.

Step 4 Check the Enable Java, Enable JavaScript, and Enable Style Sheets check boxes.

Step 5 From the Advanced drop-down list, choose Cache.

Step 6 Under Document in Cache Is Compared to Document on Network, choose Every time.

Step 7 Click OK.


Internet Explorer 5.5

If you are using Microsoft Internet Explorer 5.5 on a PC connected to the Cisco ICS 7750, or on the SPE running System Manager, follow these steps to configure it to work with System Manager.


Step 1 Open Internet Explorer.


Note During the installation of this browser, check the Install Minimal or Customize Your Browser check box. In the Component Options window in the Internet Explorer 5 section, check the Microsoft Virtual Machine check box to display applets written in Java.


Step 2 Choose Tools > Internet Options.

Step 3 In the Internet Options window, click the Advanced tab.

a. Under Microsoft VM, check the Java logging enabled and JIT compiler for virtual machine enabled check boxes.

If you do not see this section, you need to reinstall the browser and follow the instructions in the note at the beginning of this section.

b. Click Apply.

Step 4 In the Internet Options window, click the General tab.

a. In the Temporary Internet Files section, click Settings.

b. In the Settings window, choose Every visit to the page, and click OK.

Step 5 In the Internet Options window, click the Security tab.

a. Click the Trusted Sites icon, and click Sites.

b. Uncheck the Require server verification check box.

c. Click OK.

Step 6 While still in the Security tab of the Internet Options window, click Custom Level.

a. In the Security Settings window, scroll to the Microsoft VM > Java permissions section.

If you do not see this section, you need to reinstall the browser and follow the instructions in the note at the beginning of this section.

b. Choose Custom to enable Java Custom Settings.

c. Click Java Custom Settings.

Step 7 In the Trusted Sites window, click the Edit Permissions tab.

a. Under Run Unsigned Content, choose Enable.

b. Click OK.

Step 8 In the Security Settings window, click OK.

Step 9 In the Internet Options window, click the Content tab.

a. In the Personal Information section, click AutoComplete.

b. In the Use AutoComplete For section, uncheck the User Names and Passwords on Forms check box.

c. Click OK.

Step 10 In the Internet Options window, click OK.


Using ICSConfig to Configure and Verify the SPE Running System Manager

In this next stage of the process, you will use ICSConfig to configure and verify correct operation of the SPE.

To configure the SPE with ICSConfig, complete the following steps:


Step 1 Properly reseat any cards in the chassis that were unseated, and connect any cables that were removed at the beginning of the replacement process.

Step 2 On a PC connected to the ICS 7750, or on the SPE running System Manager, launch a web browser.

Step 3 Enter the following URL:

http://SPE IP address/icsconfig/

where the address entered is the IP address of the SPE running System Manager.

Step 4 Log in as administrator (user ID administrator), and enter the password (the default is changeme).

Step 5 Click ICS 7700 System Setup.

Step 6 Make any necessary changes to the configuration screens. (Refer to the Cisco ICS 7750 Installation and Configuration Guide for instructions.)


Note If you have restored system software data, you do not need to make any changes here. Instead, scroll through the pages of ICSConfig to verify that the SPE is operating correctly and has the proper settings.


Step 7 When you have configured the necessary settings, the Summary page displays a list of all of the configuration pages and the data entered in each field.

All the page names listed on the Summary page are links to the configuration pages, where you can change any of the information that you entered. To change any of the settings, click the associated hyperlinked page. When all the settings are correct, click Next to continue to the Ready to Submit page.

The Ready to Submit page provides instructions on what to do after you submit the changes to your Cisco ICS 7750. Submitting and processing these changes can take up to 20 minutes. If you have not made any changes, you can stop and exit ICSConfig instead, and proceed to Step 9.

Step 8 Click Submit.


Caution After you click Submit, do not reboot your Cisco ICS 7750 or perform any configuration tasks on the Cisco ICS 7750 during this process.

Step 9 Verify that the SPE is functioning correctly (see the "Verifying Card Installation" section).


After the SPE is configured and verified, continue with the "Accessing ICS System Manager and Restoring Cisco ICS 7750 Functionality" section.

Accessing ICS System Manager and Restoring Cisco ICS 7750 Functionality

In this procedure, you will use ICS System Manager to monitor the chassis while you reseat any cards that were unseated at the beginning of the installation process and you connect any removed cables.

Perform the following steps:


Step 1 If the SPE running System Manager has had its IP address/subnet changed as part of the restoration or configuration process, and if you are using a PC connected to the Cisco ICS 7750, change the IP address of the PC connected to the chassis to the same IP subnet. You can do this manually in Network Settings or, if your network supports it, by reenabling DHCP address resolution on the PC. (See the "Configuring Your PC IP Address" section, for details on how to access and change the PC network settings.)

Step 2 On a PC connected to the Cisco ICS 7750, or on the SPE running System Manager, launch a web browser, and access ICS System Manager by entering the following in the address field:

http://SPE IP address/ics

where the SPE IP address entered is the IP address of the SPE running System Manager.

The System Manager screen appears in the browser, and you are prompted for a user ID and password.

Step 3 In the User ID field, enter admin. In the Password field, enter the ICS super admin password (set during ICSConfig). Click Login.

Step 4 Reseat any cards that were unseated at the beginning of the installation process. It will take several minutes for each card to boot and for TFTP to initialize fully. If no cards were unseated, go to Step 5.

Step 5 When you have finished and have verified that the cards in the chassis are up and running, exit ICS System Manager, and close the web browser window.

Step 6 Tighten the lock-down screws for all the cards in the Cisco ICS 7750 chassis.

Step 7 If disconnected, reconnect the Cisco ICS 7750 to its original LAN and WAN connections.

Step 8 Connect the cables to the MRPs and ASIs, if any were removed. (Refer to the Cisco ICS 7750 Installation and Configuration Guide.)



Note When first booting MRP200, ASI81, and ASI160 cards in a chassis with a newly installed SPE running System Manager, it can take up to 4 minutes per card to configure each MRP or ASI and for TFTP to execute fully. The Flash-based MRP cards (MRP300, MRP3-8FXS, and MRP3-16FXS) may boot in less time.



Note If there was no backup of ICS System Manager data, the MRPs and ASIs must be configured again by using the IOS CLI.


If you have configured VLAN functionality on the Cisco ICS 7750, see the "Configuring VLAN Support" section.

Continue with the "Installing Applications and Restoring Saved Application Software Data" section.

Installing Applications and Restoring Saved Application Software Data

After the SPE running System Manager is restored and operational, you can install application software on it, if you wish, and restore the saved application software data, if available.

For information on how to install and configure applications on the newly installed SPE, refer to the documentation for the applications. For information on how to restore saved or backed-up application data, where such functions are available, see the application documentation.

Downgrading ICS System Software

There may be instances in which you wish to replace the current installed version of the ICS System Software with an older (lower number) version. However, the ICS System Software Setup program does not support this option during its automatic wizard-based installation.


Note ICS System Software release 2.4.0 was designed to provide enhanced functionality over prior releases. With release 2.4.0, ICS System Manager provides support for an automated installation wizard, new hardware (such as the Flash-based MRP cards) and updated IOS images for the SSP and MRPs. If you downgrade the system software on the Cisco ICS 7750 to a version prior to 2.4.0, you must use compatible hardware (non-Flash-based MRP cards) and software (ICS System Manager and the IOS images for the MRPs and SSP) included in that specific release's installation package.


To install an older version of the ICS System Software than is currently installed on an SPE, follow these steps:


Step 1 Locate the ICS System Software package to be installed on the SPE.


Note The version of ICS System Software that is installed on the SPE running System Manager should be equal to or higher than that running on the core software SPEs installed in the ICS 7750 chassis. Refer to the online help found in each ICS System Software package for guidelines on downgrading software.


Step 2 Connect a monitor, keyboard, and mouse, as described in "Appendix C, "Using Peripherals with Cisco ICS 7750 SPEs" in the Cisco ICS 7750 Troubleshooting Guide.

Step 3 If you plan to install the ICS System Software from CD-ROM, connect the USB CD-ROM drive, as described in "Appendix C, "Using Peripherals with Cisco ICS 7750 SPEs" in the Cisco ICS 7750 Troubleshooting Guide. Otherwise, if you are installing from a downloaded software package, you can skip to Step 4.

Step 4 On the SPE, use the Windows Control Panel to remove the existing ICS System Software.

Click Start > Settings > Control Panel > Add/Remove Programs. Locate the ICS System Software in the installed software list, and click Change/Remove to uninstall it.

To uninstall ICS System Manager, select ICS System Manager V3.x.x


Note Microsoft SQL Server, Java Runtime Environment (JRE), service packs and hotfixes are not uninstalled.


To uninstall ICS Core Software, select ICS Core Software V3.x.x


Note Service packs and hotfixes are not uninstalled.


Follow the prompts to restart the system.


Note An uninstall log is created when ICS System Software is uninstalled. You can use this log to verify that you successfully uninstalled the system software. Refer to the "ICS System Manager Log Files" section in Chapter 5, "Troubleshooting Cisco ICS 7750 Software" in the Cisco ICS 7750 Troubleshooting Guide.


Step 5 Insert the installation CD in the CD-ROM drive, or locate the ICS System Software package on the SPE hard drive. Run Setup to install the software. For more details on how to do this, follow the procedure as outlined in the "ICS System Software Installation" section in Chapter 4, "Installing and Upgrading Cisco ICS 7750 System Software" in the Cisco ICS 7750 Troubleshooting Guide.


Removing and Replacing ASIs, MRPs, the SSP, or the SAP

This section contains the following procedures:

Backing Up and Restoring Flash-Based MRPs, ASIs, and the SSP

Removing an ASI, MRP, SSP, or SAP

Installing or Replacing an ASI or MRP

Replacing an MRP200 or ASI Card with a Flash-Based MRP Card


Caution If you are using the VLAN functionality on the Cisco ICS 7750, the routing Flash-based MRP must be hardware and software VLAN-capable. If you have a Flash-based MRP card configured as the only VLAN router, all call processing might be lost (along with access to other IP devices) if the MRP goes offline. Disruption of call processing services may occur if the MRP is routing calls across VLANs. If fault tolerance is critical, you can use HSRP for more reliable and redundant routing. For additional information about HSRP, refer to Hot Standby Router Protocol (HSRP) Features and Functionality.

Backing Up and Restoring Flash-Based MRPs, ASIs, and the SSP

You must manually back up the IOS configuration files for any Flash-based card, including the MRP or ASI cards (MRP300, MRP3-8FXS, MRP3-16FXS), and the SSP. (See the "Backing up and Restoring the VLAN Configuration on the SSP" section for information about backing up the vlan.dat file.)

Follow these steps to back up and restore the IOS configuration files on the MRP and SSP:


Step 1 Back up the IOS configuration files, as appropriate:

If the ASI81 or MRP200 is installed in the chassis, back up its configuration files, using the ICS System Manager application. For more information, refer to the ICS System Manager online help.

If the MRP300, MRP3-8FXS, or MRP3-16FXS is installed in the chassis, follow these steps to manually back up the IOS configuration files on the card. Use the same procedure for the SSP:

a. Telnet to the MRP300, MRP3-8FXS, or MRP3-16FXS card from the SPE running System Manager or from a PC connected to the Cisco ICS 7750 so that you can enter IOS software commands.

b. Enter the enable command and your IOS enable password to enter privileged EXEC command mode:

MRP>enable
Password: password
MRP#

c. Enter the following command to display the startup configuration:

MRP#show startup-config

d. Copy and paste the output from the show startup-config command into a text file on the SPE running System Manager:

Choose Start > Run.

Enter the following command to open Notepad:

notepad.exe

Select and copy (Ctrl-C) the startup-config output from the Telnet console, and paste (Ctrl-V) the output into the Notepad window.


Note Do not include the "More" lines if they are displayed in the output. Select the contents from the Telnet console and copy them to the clipboard. Go to the Notepad window and paste the clipboard contents.


If "More" is displayed at the bottom of the Telnet console, press Spacebar to display the next screen and copy from the Telnet console again, pasting to the Notepad window. Repeat until the entire startup configuration has been displayed, copied, and pasted.

From the Notepad, choose File > Save.

e. Save the startup-config file under C:\Program Files\Cisco\TFTPPath, if saving the file on the SPE running System Manager. Name the config file in this format:

<backupname>_<hostname>

where backupname is any name you choose, and hostname is the host name of the card.

For example, an MRP300 configuration file could be named Backup1_R00ffff900073.

Step 2 After you have installed the new Flash-based MRP or SSP, restore the startup configurations that were manually backed up for these Flash-based cards from the device (computer on the network) where you stored your backup files.


Note If you stored your backup files on a remote device (computer on the network) that cannot access the SAP, you must copy the backup configuration files either to the SPE running System Manager or to a PC that is connected to the SAP console port.


a. Choose Start > Run.

b. Enter the following command to open the backup startup configuration in Notepad:

notepad.exe \\hostname\sharename\path\filename.txt

where \\hostname\sharename\path is the shared path name to the remote device (computer on the network) where you stored your backup files, and filename is the backup configuration filename for this card specified.

For example, an SSP configuration file could be named Backup1_Switch.txt, and an MRP300 configuration file could be named Backup1_R00ffff900073.txt.

c. From Notepad, choose Edit > Select All.

d. Copy the contents of the Notepad window to the clipboard.

e. Apply the backup startup configuration to the Flash-based card. Open a HyperTerminal session with the SAP.

f. Press Ctrl-backslash (\), and use the SAP menu to switch to the Flash-based card to which you want to restore the startup configuration.

g. Enter privileged EXEC mode by entering the following command:

MRP>enable

h. Enter your enable password.

i. Enter the following command to configure from the terminal:

MRP#configure terminal

j. Paste the backup startup configuration into the HyperTerminal session window.

k. Enter the following command to save the running configuration as the startup configuration:

MRP#copy running-config startup-config 

Step 3 Repeat Step 2(a) through Step 2(k) for the SSP and for every Flash-based MRP or ASI card (MRP300, MRP3-8FXS, or MRP3-16FXS) in the chassis.



Note It is important to restore only those startup configurations that were saved (backed up) at the same time that the System Manager backup procedure was performed. Do not attempt to restore manually, onto a Flash-based card, a startup configuration that was saved at a time other than when System Manager was backed up. Attempting this restoration may cause System Manager to be unable to detect and manage that Flash-based card.


Removing an ASI, MRP, SSP, or SAP

This section explains how to remove an ASI, MRP, SSP, or SAP. You do not have to turn off the power for these procedures.


Note If you have configured VLAN functionality on the Cisco ICS 7750, make sure to back up and save the configuration file on the SSP. During the backup process, you might also need to back up and restore the vlan.dat file. See the "Backing up and Restoring the VLAN Configuration on the SSP" section for additional information.


Figure 7 depicts the process of removing a card from the Cisco ICS 7750 chassis.

Figure 7 Removing Cards from the Cisco ICS 7750 Chassis

Complete the following steps to remove a system card:


Step 1 Press the SHTDN button on the card that you want to remove.

The STATUS LED on the card starts blinking. After several minutes, it will turn off. Wait for the STATUS LED to turn off before continuing.

Step 2 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle cards by the edges only, and use an ESD-preventive wrist strap or other grounding device.

Step 3 Disconnect any cables attached to the front of the card, and secure them out of the way, using cable ties, if necessary.

Step 4 Completely loosen the lock-down screws (at the top and bottom of the card).

Step 5 Press the upper and lower extractor levers outward (away from the center of the card) at the same time to disengage the card from the backplane. Pull the card out only far enough (about 1 inch) to disengage it from the backplane; do not completely remove the card from the chassis.


Caution Always use the extractor levers to disengage or seat cards. Failure to use the levers can cause erroneous system error messages that indicate a card failure. Do not use the extractor levers to lift or support the weight of the cards.

Step 6 Grasp the extractor levers and gently pull the card partially out of the chassis slot until you can grasp the card front panel with one hand. Place your other hand under the card to balance the weight of the card as you prepare to pull it out of the slot.


Warning High performance devices on system cards can get hot during operation. To remove a card, hold it by the faceplate and bottom edge. Allow the card to cool before touching any other part of it or placing it an anti-static bag.


Step 7 Pull the card straight out of the slot. Avoid touching the circuitry or any connector pins.

Step 8 Place the card on an antistatic mat or foam pad until you are ready to reinstall it in the chassis. If you plan to return the card to the factory, place it in an antistatic bag, and see the "RMA Return Instructions" section.


To install a card, see the "Installing or Replacing an ASI or MRP" section.

Installing or Replacing an ASI or MRP

This section provides procedures for installing or replacing ASIs or MRPs.

You do not need to turn off power for these procedures. Figure 8 shows how to install system cards.


Caution When you are installing cards, be sure to apply equal amounts of pressure to the top and bottom of the card. You can damage the card and the chassis backplane if you apply too much pressure to either the bottom or the top of the card.

Figure 8 Installing Cards in the Cisco ICS 7750 Chassis


Note If you wish to install a VIC, WIC, or VWIC, do not completely seat the ASI81, MRP3-8FXS, or MRP into the chassis at this time. See the "Removing and Replacing Interface Cards in ASI81s, MRP3-8FXSs, or MRPs" section for information about installing VICs, WICs, and VWICs.


Follow these steps to install an ASI or MRP:


Step 1 If you are using a PC connected to the Cisco ICS 7750, use a straight-through Ethernet cable to connect your PC Ethernet NIC to either of the 10/100 Ethernet ports (labeled 1x and 2x) on the SSP.

Step 2 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the cards only by the edges, and use an ESD-preventive wrist strap or other grounding device.


Note If you need to install or replace an interface card in an ASI81, MRP, or MRP3-8FXS, see the "Installing or Replacing an Interface Card in an ASI81, MRP, or MRP3-8FXS" section.


Step 3 Align the ASI or MRP with the upper and lower card guides in an available chassis slot, and make sure that the extractor levers are in the open position (pointing up and down).

Step 4 With the top and bottom edges of the card in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force that you use to get the card past the grounding clips. If you encounter extreme resistance, pull the card out slightly, and then push it back in again.

Step 5 Press the upper and lower extractor levers inward (toward the center of the card) at the same time until they lock into their slots. This step firmly seats the ASI or MRP into the chassis.

Step 6 To configure the ASI or MRP, complete the following steps:

a. On a PC connected to the Cisco ICS 7750 or on the SPE running System Manager, launch a web browser.

b. Enter the following URL, using the IP address of the SPE running System Manager:

http://SPE IP address/icsconfig/

c. Log in as administrator (user ID administrator), default password changeme).

d. Click Login.

e. Click ICS 7700 System Setup.

f. Make any necessary changes to the configuration screens. (Refer to the Cisco ICS 7750 Installation and Configuration Guide for instructions.)


Note If you have configured VLAN functionality on your system, use ICSConfig to configure the management VLAN IP address of the Flash-based MRP card on the primary Fast Ethernet interface 0/0 for that MRP. You cannot add a native VLAN subinterface for the Flash-based MRP, nor can you configure the primary Fast Ethernet interface on the Flash-based MRP with the command no ip address.


g. When you have configured the necessary settings, the Summary page displays a list of all of the configuration pages and the data entered in each field.

All the page names listed on the Summary page are links to the configuration pages, where you can change any of the information that you entered. To change any of the settings, click the associated hyperlinked page. When all the settings are correct, click Next to continue to the Ready to Submit page.

The Ready to Submit page provides instructions on what to do after you submit the changes to your Cisco ICS 7750. Submitting and processing these changes can take up to 20 minutes to complete.

h. Click Submit.


Caution After you click Submit, do not reboot your Cisco ICS 7750 or perform any configuration tasks on the Cisco ICS 7750 during this process.

Step 7 Verify that the ASI or MRP is correctly installed (see the "Verifying Card Installation" section).

Step 8 If you do not wish to install additional interface cards or power supply modules, secure the MRP (and any additional cards or power supply modules that you have installed) by completely tightening the captive screws at the top and bottom of the chassis slots.



Note The MRP200 and the SPE cards are designated as endpoints when using VLAN support on the Cisco ICS 7750; no VLAN configuration is required on these cards. However, switchport definitions might need to be configured on the SSP for the MRP200 or the SPE. See the "Configuring VLAN Support" section for additional information.



Note The internal port of the SSP which connects to the Flash-based MRP, that is the acting VLAN router and part of multiple VLANs, must be configured as "dot1q trunk native vlan 1." See the "Configuring VLAN Support on the SSP" section for additional information.


Replacing an MRP200 or ASI Card with a Flash-Based MRP Card

Follow these steps to replace an MRP200 or ASI card with a Flash-based MRP card (MRP300, MRP3-8FXS, or MRP3-16FXS):


Step 1 Save the existing MRP200 or ASI card configuration file in the TFTP path directory on the SPE running System Manager (C:\Program Files\Cisco Systems\TFTPPath).

The name of the configuration file will be in the format of the MRP200 or ASI card's MAC address, followed by .cfg. For example:

000196664ab7.cfg

This is a safety precaution to ensure that you have a backup of the configuration file during the MRP swap.

Step 2 Remove the MRP200 or ASI card from the chassis. See the "Removing an ASI, MRP, SSP, or SAP" section.

Step 3 Insert the Flash-based MRP card into the chassis. See the "Installing or Replacing an ASI or MRP" section.

The Flash-based MRP card will receive a DHCP address and its initial configuration from the SPE running System Manager.

Step 4 Run ICSConfig to configure the Flash-based MRP card with the same IP address as the MRP200 or ASI card that you removed from the chassis.

a. To run ICSConfig, enter the following URL into your web browser:

http://SPE IP address/icsconfig/

where the address entered is the IP address of the SPE running System Manager.

b. Log in as administrator (user ID administrator), and enter the password (the default is changeme).

c. Click ICS 7700 System Setup.

d. Assign the IP address that was configured for the old MRP200 or ASI card to the new Flash-based MRP card. (Refer to the Cisco ICS 7750 Installation and Configuration Guide for instructions.)

Step 5 In enable mode on the Flash-based MRP, execute the following command to download the original MRP200 or ASI card configuration file to the Flash-based MRP card:

MRP#copy tftp:MAC_address.cfg running-config

This command copies the MRP configuration file from TFTP to the running configuration file on the Flash-based MRP card.

Step 6 In enable mode on the Flash-based MRP, execute the following command to save the configuration file to NVRAM on the Flash-based MRP card:

MRP#copy running-config startup-config


Removing and Replacing Interface Cards in ASI81s, MRP3-8FXSs, or MRPs

You can install two WICs, VICs, or VWICs into the MRP, or you can install one WIC, VIC, or VWIC into the ASI81 or MRP3-8FXS. The MRP has two interface card slots (slot 0 and slot 1), whereas the ASI81 and MRP3-8FXS each have one interface slot (slot 1). For more information about these cards, refer to the "Processor Cards Feature Summary" chapter in the Cisco ICS 7750 System Description.

This section provides information on removing and replacing interface cards in ASI81s, MRP3-8FXSs, or MRPs.

Electrical Storm Warning

Warning Never install telephone wiring during an electrical storm.

Waarschuwing

Installeer telefoondraden nooit tijdens een onweersbui.

Varoitus

Älä asenna puhelinjohtoja ukkosmyrskyn aikana.

Attention

Ne jamais installer des câbles téléphoniques pendant un orage.

Warnung

Installieren Sie eine Telefonverkablung niemals während eines Gewitters!

Avvertenza

Mai installare cavi telefonici durante un temporale elettrico.

Advarsel

Telefonledninger skal aldri monteres i tordenvær.

Aviso

Nunca instalar fios telefónicos durante uma tempestade eléctrica.

¡Advertencia!

Nunca instale el cableado del teléfono durante una tormenta.

Varning!

Telefonledningar får aldrig anslutas under åskväder.


Telephone Jacks in Wet Locations Warning

Warning Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Waarschuwing

Installeer telefoonaansluitingen nooit op vochtige locaties tenzij de aansluiting speciaal bestemd is voor vochtige locaties.

Varoitus

Älä asenna puhelimen pistokkeita kosteisiin tiloihin, ellei pistokkeita ole nimenomaisesti suunniteltu tällaisiin tiloihin.

Attention

Ne jamais installer de prises téléphoniques dans un local humide, sauf si celles-ci sont spécifiquement conçues pour cet usage.

Warnung

Telefonanschlüsse niemals in feuchten Umgebungen installieren, es sei denn der Anschluß ist speziell für Feuchtumgebungen entwickelt!

Avvertenza

Mai installare un jack telefonico in una zona bagnata almeno che il jack sia appositamente per zone bagnate.

Advarsel

Telefonkontakter skal aldri monteres i fuktige omgivelser, med mindre kontakten er spesielt laget for våtrom.

Aviso

Nunca instalar tomadas telefónicas em locais húmidos, a menos que a tomada tenha sido especialmente concebida para esse efeito.

¡Advertencia!

Nunca instale las rosetas del teléfono en zonas mojadas a menos que la roseta se diseñe específicamente para estas.

Varning!

Endast specialkonstruerat telefonjack får installeras i våtutrymme.


Uninsulated Wires and Terminals Warning

Warning Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Waarschuwing

Raak ongeïsoleerde telefoondraden of contacten nooit aan tenzij de telefoonlijn van de netwerkinterface werd ontkoppeld.

Varoitus

Älä kosketa eristämättömiä puhelinjohtoja tai liittimiä, ellei puhelinta ole irrotettu verkkoliittymästä.

Attention

Ne jamais toucher un câble téléphonique non isolé lorsque celui-ci est connecté au port réseau.

Warnung

Niemals nicht-isolierte Telefonkabel berühren, außer wenn die Telefonleitung an der Netzwerkschnittstelle abgetrennt wurde!

Avvertenza

Mai toccare cavi telefonici o terminali non isolati almeno che le linee telefoniche non siano state disconnesse dall'interfaccia rete.

Advarsel

Telefonledninger eller -uttak som ikke er isolert, må aldri berøres, med mindre telefonlinjen er frakoplet telenettet.

Aviso

Nunca tocar em fios ou terminais telefónicos não isolados, a menos que a linha telefónica tenha sido desligada ao nível da interface da rede.

¡Advertencia!

Nunca toque los alambres o los terminales del teléfono a menos que la línea telefónica se haya desconectado en el interfaz de la red.

Varning!

Telefonlinjer måste frånkopplas vid nätverksgränssnittet innan oisolerad telefonledning eller -uttag vidrörs.


Line Installation or Modification Warning

Warning Use caution when installing or modifying telephone lines.

Waarschuwing

Wees voorzichtig bij het installeren of modificeren van telefoonlijnen.

Varoitus

Ole varovainen, kun asennat puhelinlinjoja tai teet niihin muutoksia.

Attention

Une extrême prudence est recommandée lors de l'installation ou de la modification de lignes téléphoniques.

Warnung

Achtung bei der Installation und Modifikation von Telefonleitungen!

Avvertenza

Installate o modificate le linee telefoniche con molta cautela.

Advarsel

Det må utvises forsiktighet ved montering eller justering av telefonlinjer.

Aviso

Tomar as devidas precauções ao instalar ou alterar linhas telefónicas.

¡Advertencia!

Precaución al instalar o modificar las líneas telefónicas.

Varning!

Iakttag försiktighet vid installation eller modifiering av telefonlinjer.


Telephone Use During an Electrical Storm Warning

Warning Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

Waarschuwing

Gebruik nooit een telefoon (tenzij het een draadloze telefoon is) tijdens onweer. Er bestaat een kleine kans op een elektrische schok door bliksem.

Varoitus

Vältä puhelimen (muun kuin langattoman puhelimen) käyttöä ukkosmyrskyn aikana. Salamoinnista voi aiheutua sähköiskuvaara.

Attention

Pour éviter tout risque de choc électrique lors d'un orage, il est recommandé de ne pas utiliser un téléphone autre qu'un appareil sans fil.

Warnung

Vermeiden Sie die Benutzung eines Telefons während eines Gewitters (außer eines schnurlosen Geräts). Es besteht ein geringes Risiko eines elektrischem Schlags durch Blitze.

Avvertenza

Non utilizzate il telefono (almeno che sia cellulare) durante un temporale elettrico. Ci sono rischi, anche se poco probabili, di scariche elettriche dovute a fulmini.

Advarsel

Unngå å bruke telefonen (med mindre den er trådløs) i tordenvær. Det eksisterer en minimal risiko for elektrisk støt grunnet lynnedslag.

Aviso

Evitar a utilização do telefone (que não seja do tipo sem fios) durante uma tempestade eléctrica. Pode haver o risco remoto de choque eléctrico provocado pelo relâmpago.

¡Advertencia!

Evite usar el teléfono (a excepción de un teléfono inalámbrico) durante una tormenta. Puede correr peligro por la descarga eléctrica que emite el relámpago.

Varning!

Undvik att telefonera (gäller ej trådlös telefon) under åskväder. Viss risk finns för elstöt vid blixtnedslag.


Telephone Use by Gas Leaks Warning

Warning Do not use a telephone to report a gas leak in the vicinity of the leak.

Waarschuwing

Gebruik nooit een telefoon om een gaslek te melden als de telefoon zich in de buurt van het gaslek bevindt.

Varoitus

Älä ilmoita kaasuvuodosta puhelimitse, jos olet vuodon lähettyvillä.

Attention

Ne jamais utiliser un téléphone près d'une fuite de gaz pour signaler cette fuite à votre société de distribution.

Warnung

Um ein Leck in einer Gasleitung zu melden, benutzen Sie nicht ein Telefongerät in der Nähe des Lecks.

Avvertenza

Non utilizzate un telefono per avvertire di una perdita di gas nelle vicinanze della perdita.

Advarsel

Du skal ikke bruke telefon til å melde fra om en gasslekkasje i nærheten av denne lekkasjen.

Aviso

Não utilizar o telefone para comunicar uma fuga de gás nas proximidades dessa fuga.

¡Advertencia!

No utilice un teléfono para informar de un escape de gas en la zona.

Varning!

Telefonera ej i närheten vid rapportering om gasläcka.


Installation Hazard

Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector and/or 2) while the housing is open.

Waarschuwing

Deze uitrusting dient geïnstalleerd en onderhouden te worden door onderhoudspersoneel zoals gedefinieerd door AS/NZS 3260. Als deze uitrusting onjuist op een stopcontact voor algemeen gebruik wordt aangesloten kan dit gevaarlijk zijn. De telecommunicatielijnen dienen ontkoppeld te worden 1) voordat de stekker naar de hoofdstroomtoevoer eruit wordt genomen en/of 2) terwijl de behuizing open is.

Varoitus

Huoltohenkilöstön on asennettava ja huollettava tämä laite AS/NZS 3260:n määräysten mukaisesti. Laitteen virheellinen kytkeminen yleispistorasiaan voi aiheuttaa vaaratilanteita. Tietoliikennejohdot on irrotettava 1) ennen kuin päävirtaliitin irrotetaan pistorasiasta ja/tai 2) kun kotelo on auki.

Attention

Cet équipement ne doit être installé et entretenu que par du personnel d'entretien comme défini par la réglementation AS/NZS 3260. Un branchement incorrect de cet équipement à une prise de courant peut créer une situation dangereuse. Les lignes de télécommunications doivent être déconnectées 1) avant de débrancher le connecteur d'alimentation principal et/ou 2) lorsque le boîtier est ouvert.

Warnung

Dieses Gerät ist nur von ausgebildetem Personal zu installieren und zu warten (lt. Definition in AS/NZS 3260). Fälschliches Anschließen des Geräts an eine normale Steckdose könnte gefährlich sein. Die Telekommunikationsleitungen dürfen 1) beim Herausziehen des Netzsteckers und/oder 2) bei geöffnetem Gehäuse nicht angeschlossen sein.

Avvertenza

Questo apparecchio deve essere installato e mantenuto in efficienza esclusivamente da personale tecnico che soddisfi i requisiti specificati nelle norme AS/NZS 3260. Un collegamento errato di questo apparecchio ad una presa di uso generale può essere pericoloso. Le linee di telecomunicazione vanno scollegate sia prima di scollegare la spina dell'alimentazione di rete sia prima di aprire l'involucro (non ricollegarle finché non si chiude l'involucro).

Advarsel

Dette utstyret må monteres og vedlikeholdes av vedlikeholdspersonell i henhold til AS/NZS 3260. Feilaktig tilkopling av dette utstyret til et vanlig strømuttak kan medføre fare. Telekommunikasjonslinjene må være frakoplet 1) før strømledningen trekkes ut av kontakten og/eller 2) mens huset er åpent.

Aviso

A instalação e a manutenção deste equipamento devem ser realizadas por pessoal da assistência, conforme definido na norma AS/NZS 3260. A ligação incorrecta deste equipamento a uma tomada de utilização geral poderá ser perigosa. As linhas de telecomunicações têm de estar desligadas 1) antes de desligar a ligação à corrente principal e/ou 2) enquanto a caixa estiver aberta.

¡Advertencia!

Este equipo se debe instalar y mantener solamente por personal de servicio, según definido por AS/NZS 3260. La conexión incorrecta de este equipo a una toma o receptáculo de tipo general podría resultar peligrosa. Las líneas de telecomunicaciones deben desconectarse 1) antes de desenchufar el conector principal de energía y 2) mientras la caja esté abierta.

Varning!

Denna utrustning måste installeras och underhållas av servicepersonal enligt AS/NZS 3260. Felaktig anslutning av denna utrustning till ett vanligt vägguttag kan medföra fara. Teleledningarna måste kopplas ifrån innan väggkontakten dras ut och/eller innan höljet tas av.


Before You Begin

Before you install an interface card into an MRP, ASI81, or MRP3-8FXS, do the following:

Verify that the MRP, ASI81, or MRP3-8FXS card is installed with the minimum IOS release that supports the interface card you wish to install.

VICs and VWICs installed in MRP, ASI81, or MRP3-8FXS cards might require additional digital signal processors (DSPs) for processing heavier voice traffic. You can install up to two packet voice/data modules (PVDMs) on each MRP, ASI, or MRP3-8FXS card. PVDMs contain DSP chips that give MRP, ASI, and MRP3-8FXS cards more processing power. Before you can configure the digital voice ports, the PVDM must be installed on the MRP before the VIC is installed; otherwise, the Cisco ICS 7750 will not recognize the voice port. For more information about installing PVDMs, refer to the Installing Memory, PVDM, and VPN Modules in ASI Cards, MRP Cards, and SPE Cards document. For more information on PVDM requirements, refer to "PVDM Requirements" in the Cisco ICS 7750 Installation and Configuration Guide.


Note To see a list of voice ports on the Cisco ICS 7750, use the IOS show running-config or show diag command.



Note For a list of supported WICs, VICs, and VWICs, and the Cisco IOS release that is required for each, refer to the "Processor Cards Feature Summary" chapter in the Cisco ICS 7750 System Description.


Installing or Replacing an Interface Card in an ASI81, MRP, or MRP3-8FXS

If the Cisco ICS 7750 is running, do not power down the chassis by using the chassis power supply switch or by unplugging the power supply. Powering down the chassis may cause the Cisco ICS 7750 to lose important configuration data and will interrupt any applications or functions that are running on other cards in the chassis.


Note If an existing Flash-based MRP card has been configured as a VLAN router and is being replaced by another Flash-based MRP card, you must manually reconfigure the Flash-based MRP to make the card functional for VLAN usage.

You must also ensure that the internal port of the SSP, which connects to the Flash-based MRP that is the VLAN router and part of multiple VLANs, is configured as "dot1q trunk native vlan 1." See the "Configuring VLAN Support on the SSP" section for additional information.


To install an interface card in an ASI81, MRP, or MRP3-8FXS, follow these steps:


Step 1 Shut down operations on the ASI81, MRP, or MRP3-8FXS, by pressing the card's SHTDN button.

The STATUS LED on the card starts blinking; after several minutes, it turns off. Wait for the STATUS LED to turn off before you continue.

Step 2 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the cards only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 3 Disconnect any cables attached to the front of the interface card, and secure them out of the way, using cable ties, if necessary.

Step 4 Completely loosen the lock-down screws (at the top and bottom of the ASI81, MRP, or MRP3-8FXS).

Step 5 Press the upper and lower extractor levers outward (away from the center of the card) at the same time to disengage the ASI81, MRP, or MRP3-8FXS from the backplane. Pull the card out only far enough (about 1 inch) to disengage it from the backplane; do not completely remove the card from the chassis.


Caution Always use the extractor levers to disengage or seat cards. Failure to use the levers can cause erroneous system error messages indicating a card failure. Do not use the extractor levers to lift or support the weight of the cards.


Warning High performance devices on system cards can get hot during operation. To remove a card, hold it by the faceplate and bottom edge. Allow the card to cool before touching any other part of it or placing it an anti-static bag.


Step 6 If you are replacing an interface card in an ASI81, MRP, or MRP3-8FXS, or if there is an interface card filler panel in the ASI81, MRP, or MRP3-8FXS, use either a number-2 Phillips screwdriver or a small flat-blade screwdriver to remove the interface card or filler panel.

Place the interface card that you removed on a foam mat, or inside a plastic bag, if you are returning the card. Save the filler panel for future use.


Note If you remove an interface card while the system card is running, the configuration of the interface card is lost until the system card reboots.


Step 7 Align the new interface card with the guides in the ASI81, MRP, or MRP3-8FXS. Slide the card gently into the slot. Figure 9 shows the installation of an interface card into an MRP.

Figure 9 Installing an Interface Card into an MRP

Step 8 Push the interface card into place until you feel its edge connector mate securely with the connector in the ASI81, MRP, or MRP3-8FXS.

Step 9 Tighten the interface card mounting screws into the ASI81, MRP, or MRP3-8FXS by using a Phillips or flat-blade screwdriver.


Note If any interface card slot on the ASI81, MRP, or MRP3-8FXS is unoccupied, install a filler panel to enable proper airflow.


Step 10 Align the ASI81, MRP, or MRP3-8FXS with the upper and lower card guides in the chassis slot, and make sure that the extractor levers are in the open position (away from the center of the card).

Step 11 With the top and bottom edges of the ASI81, MRP, or MRP3-8FXS in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force that you use to get the card past the grounding clips. If you encounter extreme resistance, pull the card out slightly, and push it back in again.

Step 12 Press the upper and lower extractor levers inward (toward the center of the card) at the same time until they lock into their slots. This step firmly seats the ASI81, MRP, or MRP3-8FXS into the chassis.

Step 13 Connect the cables to the ASI81, MRP, or MRP3-8FXS interfaces (refer to the Cisco ICS 7750 Installation and Configuration Guide).

Step 14 The STATUS LED on the ASI81, MRP, or MRP3-8FXS blinks green as it boots. Wait until the LED turns green, and then verify the interface card installation. See the "Verifying Card Installation" section.


Configuring VLAN Support on the Flash-Based MRP

If you have configured VLAN functionality on your system, and the Flash-based MRP card is the designated VLAN router, you need to manually configure the Flash-based MRP. Follow the steps in the example below to configure the Flash-based MRP card. (The following are sample configurations [for example, VLAN 3 and VLAN 4, and some QoS settings]. You can choose whatever numbers you wish to define for your VLAN and QoS configurations.)


Step 1 Select Fast Ethernet 0/0 for the trunk configuration:

MRP#configure terminal
MRP(config)# int fastEthernet 0/0

This address is assigned by ICSConfig and should not be modified or removed by the user:

MRP(config-if)#ip address 10.10.10.6 255.255.255.0
MRP(config-if)#no shut
MRP(config-if)#exit

A subinterface with native VLAN should not be created on the MRP300.

Step 2 Create VLAN 3 on the MRP300:

MRP(config)#int fastEthernet 0/0.3

Step 3 Enter the trunking encapsulation as dot1q:

MRP(config-if)#encapsulation dot1q 3

Step 4 Configure layer 3 information on the subinterface 0/0.3:

MRP(config-if)#ip address 10.10.11.6 255.255.255.0
MRP(config-if)#exit

Step 5 Create VLAN 4 on the MRP300:

MRP(config)#int fastEthernet 0/0.4

Step 6 Enter the trunking encapsulation as dot1q:

MRP(config-if)#encapsulation dot1q 4

Step 7 Configure layer 3 information on the subinterface 0/0.4:

MRP(config-if)#ip address 10.10.12.6 255.255.255.0
MRP(config-if)#exit
MRP(config)#^Z

Step 8 Save the configuration:

MRP#copy run start

Step 9 Enable Cisco Express Forwarding (CEF):

MRP(config)#ip cef

To configure layer 3 to layer 2 service-policy mapping in the Fast Ethernet subinterface, follow Step 10 through Step 12 in the example below. (The Cisco ICS 7750 does not support layer 3 to layer 2 service-policy mapping in the Fast Ethernet main interface.)

Step 10 Set the class-map:

MRP(config)#class-map l3-to-l2-high
MRP(config-cmap)#match ip dscp cs5
MRP(config)#class-map l3-to-l2-med 
MRP(config-cmap)#match ip dscp cs3
MRP(config)#class-map l3-to-l2-low
MRP(config-cmap)#match ip dscp cs1

Step 11 Set the policy map:

MRP(config)#policy-map output-l3-to-l2
MRP(config-pmap)#class l3-to-l2-high
MRP(config-pmap-c)#set cos 5
MRP(config-pmap-c)#exit
MRP(config-pmap)#class l3-to-l2-med
MRP(config-pmap-c)#set cos 3
MRP(config-pmap-c)#exit
MRP(config-pmap)#class l3-to-l2-low
MRP(config-pmap-c)#set cos 0

Step 12 Apply the policy map:

MRP(config)#interface fastEthernet 0/0.2
MRP(config-if)#service-policy output output-l3-to-l2
MRP(config-if)#^Z

To configure layer 2 to layer 3 service-policy mapping in the Fast Ethernet subinterface, follow Step 13 through Step 15 as shown in the example configurations below.

Step 13 Set the class-map for layer 2 to layer 3 mapping:

MRP(config)#class-map match-all l2-to-l3-high
MRP(config-cmap)#match cos 4 5
MRP(config)#class-map match-all l2-to-l3-med
MRP(config-cmap)#match cos 2 3
MRP(config)#class-map match-all l2-to-l3-low
MRP(config-cmap)#match cos 0 1

Step 14 Set the policy map for layer 2 to layer 3 mapping:

MRP(config)#policy-map input-l2-to-l3
MRP(config-pmap)#class l2-to-l3-high
MRP(config-pmap-c)#set ip dscp cs5
MRP(config-pmap-c)#exit
MRP(config-pmap)#class l2-to-l3-med
MRP(config-pmap-c)#set ip dscp cs3
MRP(config-pmap-c)#exit
MRP(config-pmap)#class l2-to-l3-low
MRP(config-pmap-c)#set ip dscp cs1

Step 15 Apply the policy map for layer 2 to layer 3 mapping:

MRP(config)#interface fastethernet 0/0.2
MRP(config-if)#service-policy input input-l2-to-l3
MRP(config-if)#^Z


Note You must also ensure that the internal port of the SSP, which connects to the Flash-based MRP that is acting as the VLAN router and part of multiple VLANs, is configured as "dot1q trunk native vlan 1." See the "Configuring VLAN Support on the SSP" section for more details.


Replacing the SSP and the SAP

This section provides procedures for the following tasks:

Backing up and Restoring the VLAN Configuration on the SSP

Replacing the SSP

Replacing the SAP

Backing up and Restoring the VLAN Configuration on the SSP

The VLAN configuration is saved in Flash memory on the SSP under the vlan.dat file. If you have configured VLAN functionality on the Cisco ICS 7750, make sure that you back up and save the configuration file on the SSP. (See the "Backing Up and Restoring Flash-Based MRPs, ASIs, and the SSP" section for additional information about the configuration file.)

The procedure to back up the vlan.dat file is the same procedure that is used to copy a Flash file to a network server.

To copy the vlan.dat file to a TFTP network server, use the following command in EXEC mode from the command prompt on the SSP:

Switch#copy flash:vlan.dat tftp://<ip address of server>/<dir>/<filename>

where <ip address of server> is the IP address of the TFTP server, <dir> is the directory name on the TFTP server, and <filename> is the filename to write on the TFTP server.

You might also need to restore the VLAN information, depending on the VTP mode of the SSP.

If the SSP is operating in VTP transparent mode, back up and restore the vlan.dat file, along with the configuration text. Reload the SSP for the vlan.dat file to take effect.

If the SSP is operating in VTP server or client mode, the SSP will relearn the VLAN configuration in the network through VTP advertisements. You will need to reset the correct VTP domain and password on the SSP. Refer to the "Configuring VLANs" section in the Catalyst 2900 XL and Catalyst 3500 XL Software Configuration Guide, Releases 12.0(5)WC4 and 12.0(5)WC5.

Problems with VTP advertisements might occur in the following situations:

If the configuration text contains "switchport access vlan 3" and no vlan.dat file, the SSP will go into VTP transparent mode. The SSP will create a vlan.dat file using the current information in its configuration, and choose a domain name of UPGRADE. In this case, use the CLI to configure the SSP for server or client mode and define the correct domain name and password. The SSP should learn the VLAN configuration from the advertisements. For additional information, refer to the "Configuring VLANs" section in the Catalyst 2900 XL and Catalyst 3500 XL Software Configuration Guide, Releases 12.0(5)WC4 and 12.0(5)WC5.

If all switches in the network lose power and the SSP is the only server switch (with no vlan.dat file), the client will not advertise after it reboots. In this case, all VLANs need to be recreated on the server.

If the SSP (in server or client mode) is the only switch in the VTP domain, the SSP will not receive any advertisements; therefore, the vlan.dat file should be backed up and restored as in VTP transparent mode.


Tip It is recommended that you run the SSP in VTP transparent mode if the SSP is not part of any VTP domain.


To restore the vlan.dat file and copy the system image into the current Flash configuration on the SSP, reload the SSP, and execute the following command:

Switch#copy tftp://<ip address of server>/<dir>/<filename> flash:vlan.dat

where <ip address of server> is the IP address of the TFTP server, <dir> is the directory name on the TFTP server, and <filename> is the filename to copy from on the TFTP server.


Note Refer to Loading and Maintaining System Images for additional information about copying images between Flash memory and a network server.


Replacing the SSP

Complete the following steps to replace the SSP (see Figure 8).


Note For this procedure, install only a new SSP (an SSP that has never been installed or configured) that is in a factory configuration (with no configuration data stored on it).



Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the cards only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Align the SSP with the upper and lower card guides in slot 7 of the chassis, and make sure that the extractor levers are in the open position (pointing up and down).

Step 3 With the top and bottom edges of the card in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force that you use to get the card past the grounding clips, particularly if this is the first time a card has been inserted in this slot. If you encounter extreme resistance, pull the card out slightly, and then push it back in again.

Step 4 Press the upper and lower extractor levers inward (toward the center of the card) at the same time until they lock into their slots. This step firmly seats the SSP into the chassis.

ICS System Manager will assign an IP address to the SSP that is different from the IP address of the original SSP.

Step 5 To configure the SSP, complete the following steps:

a. On a PC connected to the Cisco ICS 7750 or on the SPE running System Manager, launch a web browser.

b. Enter the following URL, using the IP address of the SPE running System Manager:

http://SPE IP address/icsconfig/

c. Log in as administrator (using the user ID administrator), and enter the password (the default is changeme).

d. Click Login.

e. Click ICS 7700 System Setup.

f. Make any necessary changes to the configuration screens. (Refer to the Cisco ICS 7750 Installation and Configuration Guide for configuration instructions.)

g. When you have entered the necessary settings, the Summary page displays a list of all the configuration pages and the data entered in each field.

All the page names listed on the Summary page are links to the configuration pages, where you can change any of the information that you entered. To change any of the settings, click the associated hyperlinked page. When all the settings are correct, click Next to continue to the Ready to Submit page.


Note Upon insertion of a replacement SSP into the chassis, the new SSP obtains an IP address that is different from the original IP address of the SSP. However, you can reassign the original IP address to the new SSP by using ICSConfig.


The Ready to Submit page provides instructions on what to do after you submit the changes to your Cisco ICS 7750. Submitting and processing these changes can take up to 20 minutes to complete.

h. Click Submit.


Caution After you click Submit, do not reboot your Cisco ICS 7750 or perform any configuration tasks on the Cisco ICS 7750 until this process is completed.

Step 6 Verify that the SSP is correctly installed (see the "Verifying Card Installation" section).

Step 7 If you do not wish to install additional cards or power supply modules, secure the SSP (and any additional cards or power supply modules that you have installed) by completely tightening the lock-down screws at the top and bottom of the cards.


Configuring VLAN Support on the SSP

If you have configured VLAN functionality on the Cisco ICS 7750, follow these steps:


Step 1 Restore the configuration file that you backed up on the SSP, and also restore the vlan.dat file, if necessary. See the "Backing up and Restoring the VLAN Configuration on the SSP" section.

Step 2 Check to make sure that the management VLAN on the SSP is configured as VLAN 1; this is necessary for the SPE to access the SSP. See the following example:

Switch#configure terminal
Switch(config)#interface VLAN 1
Switch(config-subif)#management

Step 3 Check to make sure that the interface for the SPE or the MRP200 (in the slot in which the SPE or the MRP200 is connected) is configured as "static access vlan 1." This is the default setting on a new SSP; if the configuration is missing, configure the interface.

For example, if the SPE is installed in slot 5, the configuration on the SSP would look as follows:

Switch#configure terminal
Switch(config)#int fastEthernet 0/7
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 1


Note The internal port of the SSP which connects to the SPE or to the MRP200 must be defined as "static access vlan 1."


Step 4 If you want to define CoS, set layer 2 CoS to 5 for all packets leaving from the port configured in
Step 3.

Switch(config)#int fastEthernet 0/7
Switch(config-if)#switchport priority default 5

Step 5 Configure the internal port of the SSP that connects to the Flash-based MRP (which is the acting VLAN router and part of multiple VLANs), as "dot1q trunk native vlan 1."

For example, if the Flash-based MRP is installed in slot 1, the configuration on the SSP would look as follows:

Switch#configure terminal
Switch(config)#interface fastEthernet 0/3
Switch(config-if)#switchport mode trunk
Switch(config-if)#switchport trunk encapsulation dot1q
Switch(config-if)#switchport trunk native vlan 1


Note The internal port of the SSP which connects to the Flash-based MRP, which would be part of multiple VLANs, must be configured as "dot1q trunk native vlan 1."


Step 6 Configure at least one of the external ports on the SSP that connects to other switches as "dot1q trunk" to enable the exchange of 802.1p/q header information between the switches.

For example:

Switch#configure terminal
Switch(config)#interface fastEthernet 0/1
Switch(config-if)#switchport mode trunk
Switch(config-if)#switchport trunk encapsulation dot1q
Switch(config-if)#switchport trunk native vlan 1



Note For detailed information about VLAN support on the Cisco ICS 7750, refer to the Cisco ICS 7750 Installation and Configuration Guide. For information about configuring VLANs, refer to the "Configuring VLANs" section in the Catalyst 2900 XL and Catalyst 3500 XL Software Configuration Guide, Releases 12.0(5)WC4 and 12.0(5)WC5.


Replacing the SAP

Complete the following steps to replace the SAP (see Figure 8).


Note For this procedure, install only an SAP that is in a factory configuration (with no IOS enable password stored on it).



Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the cards only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Align the SAP with the upper and lower card guides in slot 8 of the chassis, and make sure that the extractor levers are in the open position (pointing up and down).

Step 3 With the top and bottom edges of the card in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force that you use to get the card past the grounding clips, particularly if this is the first time a card has been inserted in this slot. If you encounter extreme resistance, pull the card out slightly, and then push it back in again.

Step 4 Press the upper and lower extractor levers inward (toward the center of the card) at the same time until they lock into their slots. This step firmly seats the SAP into the chassis.

Step 5 You do not need to configure any settings for the SAP. However, verify that the SAP is functioning correctly (see the "Verifying Card Installation" section).

Step 6 If you do not wish to install additional cards or power supply modules, secure the SAP (and any additional cards or power supply modules that you have installed) by completely tightening the lock-down screws at the top and bottom of the cards.


Removing and Replacing Power Supply Modules

Cisco ICS 7750 power supply modules are hot-swappable. The power supply module remains off until it is firmly seated. If two power supply modules are installed in the chassis, you can install or remove one power supply module or turn on or off one power supply module without affecting system performance.


Caution If your system has only one power supply module installed and you need to hot swap the power supply module, install the new power supply module before removing the old one.


Warning Before working on a system that has an on/off switch, turn OFF the power and unplug the power cord.



Warning Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.



Warning This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the two power supply cords before servicing the unit.


Removing Power Supply Modules

Figure 10 shows how to remove a power supply from the chassis.

Figure 10 Removing a Power Supply Module from the Chassis

Complete the following steps to remove a power supply module (see Figure 10):


Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the modules only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Loosen the two small Phillips screws on the top and bottom of the power supply module.

Step 3 Grasp the handle on the front of the power supply module, and gently pull the unit straight out of the chassis until it releases from the backplane connector.

Step 4 Continue to pull the power supply module out until it is free of the chassis.


Installing Power Supply Modules

Follow these steps to install a new power supply module:


Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the modules only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Align the power supply module with the guides in the power supply module slot.

Step 3 Slowly push the power supply module toward the rear of the chassis until its connector aligns with the connector on the backplane. Do not force the connection.

Step 4 Continue to push the power supply module toward the rear of the chassis until the connector is firmly seated.

Step 5 If you do not wish to install additional power supply modules or cards, secure the power supply module (and any additional cards or power supply modules that you have installed) by completely tightening the lock-down screws at the top and bottom of the cards.


Removing and Replacing the Fan Tray

The chassis includes four fans in a front-accessible, hot-swappable fan tray. The fans cool the chassis slots, the SPE hard-disk drives, and the power supply modules. Air is taken in at the bottom-front of the chassis and is exhausted out the top-rear. Fan speeds are affected by the ambient temperature and controlled by the SAP. The fans provide temperature and fan speed readings to the SAP that enable the SAP to monitor the cooling operation. Individual fans are replaced by removing and replacing the entire fan tray.

You do not need to power down the chassis for this procedure.


Caution Do not operate the system for more than 1 minute with the fan tray removed.

Removing the Fan Tray

Figure 11 shows how to remove the fan tray.

Figure 11 Removing the Fan Tray from the Chassis

Complete the following steps to remove the fan tray (see Figure 11):


Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the modules only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Use a Phillips screwdriver to loosen the two lock-down screws at the bottom of the fan tray.

Step 3 Grasp the front of the fan tray, and slowly pull the tray out of the chassis. Support the fan tray from the bottom, and lift the back edge of it over the front lip of the chassis.


Installing a Fan Tray

Complete the following steps to install a fan tray:


Step 1 Put on an ESD-preventive wrist strap, and attach it to an unpainted chassis surface.


Caution To prevent ESD damage, handle the modules only by the edges, and use an ESD-preventive wrist strap or other grounding device.

Step 2 Slowly slide the fan tray into the chassis. Align the fan tray along the chassis guides and rails during insertion.

Insert the unit with a single, steady motion. Bouncing the fan tray during insertion might cause an alarm condition in the system. The unit should not be forced into the slot.

Step 3 Tighten the two lock-down screws located on the bottom front of the fan tray.

Step 4 Reset the clock in Fan Manager in ICS System Manager. For additional information, refer to the ICS System Manager online help.


Verifying Card Installation

To verify that the cards you have just installed are operating correctly, verify that the LEDs on those cards are functioning as described in Table 2.


Note The ALARM LED on Cisco ICS 7750 cards turns yellow during the POST. If the ALARM LED on any card does not turn off at the completion of POST, that card is not functioning correctly. For general information on solving problems with cards, refer to Chapter 5, "Solving Hardware Problems," in the Cisco ICS 7750 Troubleshooting Guide.


Table 2 Using LEDs to Verify Card Installation 

Card
LED
Verify the Following:

SAP

STATUS

Blinks green while the card is booting up and running the POST.

Green after the card boots up, the POST is complete, and the card is operating correctly.

SAP

PWR1

Green when the power supply module is operating correctly and supplying power to the system. (If there are two power supply modules installed, check both the PWR1 LED and the PWR2 LED.)

SSP

STATUS

Blinks green while the card is booting up.

Green after the card boots up, the POST is complete, and the card is operating correctly.

SSP

1x

Green shows that there is Ethernet link integrity on this port.

Blinks green when data is being transmitted on this port.

SSP

2x

Green shows there is Ethernet link integrity on this port.

Blinks green when data is being transmitted on this port.

MRP, ASI

STATUS

Blinks green while the card is booting up.

Green after the POST is complete and the card is operating correctly.

MRP, ASI81, MRP3-8FXS

SLOT 0

Check this LED on all MRPs, ASI81s, and MRP3-8FXSs that have a WIC, VIC, or VWIC installed in slot 0:

Green shows that the WIC, VWIC, or VIC is correctly installed in the slot.

Off means that no card is installed in the slot or that a card is incorrectly installed in the slot.

MRP, ASI81, MRP3-8FXS

SLOT 1

Check this LED on all MRPs, ASI81s, and MRP3-8FXSs that have a WIC, VIC, or VWIC installed in slot 1:

Green shows that the WIC, VWIC, or VIC is correctly installed in the slot.

Off means that no card is installed in the slot or that a card is incorrectly installed in the slot.

SPE

STATUS

Blinks green when the POST is in process or the card is shutting down.

Green when the POST is complete, the card initialization is complete, and the card is operating correctly.

Off when the shutdown process is complete (indicates that the card can be removed from the chassis or that power is off for the entire Cisco ICS 7750).

WIC, VIC, or VWIC

Depends on card

Refer to the Cisco ICS 7750 Troubleshooting Guide to verify the LED activity for the specific WIC, VIC, or VWICs that are installed in MRPs and ASI81s.


RMA Return Instructions

Under the terms and conditions of the Cisco Systems return materials authorization (RMA) policy, any replaced RMA parts must be returned to Cisco Systems.

Follow these guidelines to return parts:

Use the disposable grounding wrist trap when packing and handling electronic part(s).

Reuse the original packaging material to return electronic parts.

Affix an RMA return shipping label to the outside of each package.

Write the RMA number on the outside of all packages you return and in the reference field
(Section 2) on the waybill.

Return the parts within ten days of the date that you receive the replacement parts, or you will be billed for the outstanding parts at list price. If you are unable to return the parts within this time frame, you must call Asset Recovery at 408 526-7284 to get an approved extension.

You are responsible for all return shipping costs and customs duties. For all non-U.S. returns, you must include five copies of the proforma/customs invoice for each shipment, which lists the following items: RMA number; value of the items; description of items (including the Cisco product number).

Send a copy of the waybill and flight details by fax to Cisco USA at 408 526-5533. You can also send a copy of the waybill and flight details by e-mail to asset-recovery@cisco.com. Either method eliminates the need for further information from you and assists Cisco Systems in closing the RMA.

For U.S. returns, please send a copy of the ship date and waybill tracking number as follows:

Fax: 408 526-5533

E-mail: asset-recovery@cisco.com

For all returns, ship the return parts freight-prepaid to:

Cisco Systems
RMA Receiving
2011A Senter Road
Docks 2-3-4
San Jose, CA 95112
Attention: RMA #

Checking the Status of Returned RMA Parts

To check the status of your RMA on the web, go to the following website:

http://www.cisco.com/cgi-bin/front.x/agents/svo_tools/SVOStatusDispatcher

If you have questions, please use any of the following methods to contact Cisco Systems:

For U.S. customers: 800 800-1180, extension 6-7284

For international customers: 408 526-7284

For all customers:

FAX number: 408 526-5533

Electronic mail: asset-recovery@cisco.com

Obtaining Documentation

The following sections explain how to obtain documentation from Cisco Systems.

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at the following URL:

http://www.cisco.com

Translated documentation is available at the following URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering Documentation

Cisco documentation is available in the following ways:

Registered Cisco Direct Customers can order Cisco product documentation from the Networking Products MarketPlace:

http://www.cisco.com/cgi-bin/order/order_root.pl

Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store:

http://www.cisco.com/go/subscription

Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco corporate headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

If you are reading Cisco product documentation on Cisco.com, you can submit technical comments electronically. Click Feedback at the top of the Cisco Documentation home page. After you complete the form, print it out and fax it to Cisco at 408 527-0730.

You can e-mail your comments to bug-doc@cisco.com.

To submit your comments by mail, use the response card behind the front cover of your document, or write to the following address:

Cisco Systems
Attn: Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.

Cisco.com

Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you to

Streamline business processes and improve productivity

Resolve technical issues with online support

Download and test software packages

Order Cisco learning materials and merchandise

Register for online skill assessment, training, and certification programs

You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com, go to the following URL:

http://www.cisco.com

Technical Assistance Center

The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC Web Site and the Cisco TAC Escalation Center.

Inquiries to Cisco TAC are categorized according to the urgency of the issue:

Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.

Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.

Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.

Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.

Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of service contracts, when applicable.

Cisco TAC Web Site

The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC Web Site, go to the following URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco services contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to the following URL to register:

http://www.cisco.com/register/

If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com registered user, you can open a case online by using the TAC Case Open tool at the following URL:

http://www.cisco.com/tac/caseopen

If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC Web Site.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority level 2; these classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer will automatically open a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled; for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). In addition, please have available your service agreement number and your product serial number.