Installing the ONS 15454 SDH Air Ramp Rack Mounting Brackets

Table Of Contents

Installing the ONS 15454 SDH Air Ramp Rack Mounting Brackets

Air Ramp Kit

Install the Mounting Brackets

Related Documentation

Obtaining Documentation and Submitting a Service Request


Installing the ONS 15454 SDH Air Ramp Rack Mounting Brackets


Product Name: 15454E-ARBK-KIT=

This document provides installation procedures for installing mounting brackets on the ONS 15454 SDH Air Ramp shelf, to allow the shelf assembly to be installed in a 19 in. IEC rack (IEC-297-1), or 19/23 in. ANSI racks, and ETSI racks, as defined in ETS 300 119-1[2,3,4]. This Air Ramp mounting kit provides brackets and instructions to forward-mount (38 mm from front) the ONS 15454 SDH Air Ramp. Use this document in conjunction with the Cisco ONS 15454 SDH Procedure Guide.

This document contains the following sections:

"Air Ramp Kit" section

"Install the Mounting Brackets" section

"Related Documentation" section

"Obtaining Documentation and Submitting a Service Request" section

This document contains the following procedures:

"Install the Mounting Brackets" procedure

Air Ramp Kit

The Air Ramp rack mounting kit for the ONS 15454 SDH shelf includes the following items.

19/23 in. brackets (2)

Pan Head M4.0 x 8mm mounting screws (2)

Install the Mounting Brackets


Step 1 Verify the rack type for your air ramp installation. The brackets in this kit are compatible with the following racks.

19in racks as defined in IEC 297-1(2)

19 in. or 23 in. ANSI racks as defined in ETS 300 119-1 (2,3,4)

19 in. ETSI racks as defined in ETS 300 119-1 (2,3,4)

Step 2 Align the mounting bracket screw holes against the shelf assembly screw holes according to Figure 1. The bracket mounting holes will align with the forward-most mounting holes on the air ramp. When aligned properly the mounting flange will be 38 mm from the front edge of the air ramp.

Step 3 Insert the screws (2 places) as shown in Figure 1 and tighten.

Step 4 Repeat for the other side of the assembly.


Figure 1 Positioning the mounting brackets

Refer to Cisco ONS 15454 SDH Procedure Guide for procedures to install the air ramp in a rack.

Related Documentation

Cisco ONS 15454 SDH Procedure Guide

Cisco ONS 15454 SDH Troubleshooting Guide

Cisco ONS 15454 SDH Reference Manual