Cisco ONS 15454 Hardware Installation Guide
Appendix A, Hardware Specifications
Downloads: This chapterpdf (PDF - 404.0KB) The complete bookPDF (PDF - 90.39MB) | Feedback

Table of Contents

Hardware Specifications

A.1 ONS15454 Shelf Specifications

A.1.1 Bandwidth

A.1.2 Configurations

A.1.3 Cisco Transport Controller

A.1.4 External LAN Interface

A.1.5 TL1 Craft Interface

A.1.6 Modem Interface

A.1.7 Alarm Interface

A.1.8 EIA Interface (ANSI only)

A.1.9 BITS Interface (ANSI only)

A.1.10 System Timing

A.1.11 System Power

A.1.12 Fan Tray

A.1.13 System Environmental Specifications

A.1.14 Dimensions

A.2 ONS15454M2 Shelf Specifications

A.2.1 Bandwidth

A.2.2 Configurations

A.2.3 Cisco Transport Controller

A.2.4 External LAN Interface for EMS

A.2.5 TL1 Craft Interface

A.2.6 Modem Interface

A.2.7 Alarm Interface

A.2.8 Passive Unit Remote Inventory

A.2.9 BITS Interface

A.2.10 System Timing

A.2.11 System Power

A.2.12 Fan Tray

A.2.13 System Environmental Specifications

A.2.14 Dimensions

A.3 ONS15454M6 Shelf Specifications

A.3.1 Bandwidth

A.3.2 Configurations

A.3.3 Cisco Transport Controller

A.3.4 External LAN Interface for EMS

A.3.5 TL1 Craft Interface

A.3.6 Modem Interface

A.3.7 Alarm Interface

A.3.8 Passive Unit Remote Inventory

A.3.9 BITS Interface

A.3.10 System Timing

A.3.11 System Power

A.3.11.1 AC Power Specifications

A.3.11.2 DC Power Specifications

A.3.11.3 Power Calculation

A.3.12 Fan Tray

A.3.13 System Environmental Specifications

A.3.14 Dimensions

Hardware Specifications

This appendix contains hardware and software specifications of the ONS 15454 (ANSI and ETSI), ONS 15454 M2, and ONS 15454 M6 shelf.


Note Unless otherwise specified, “ONS 15454” refers to both ANSI and ETSI shelf assemblies.



Note Unless otherwise specified, the ECU module refers to the ECU, ECU2, and ECU-60V units. For details about the various ECU modules, see the “External Connection Units” section.


The following sections are included:

A.1 ONS 15454 Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.

A.1.1 Bandwidth

The ONS 15454 has these bandwidth specifications:

  • Total bandwidth: 240 Gbps
  • Data plane bandwidth: 160 Gbps
  • SONET/SDH plane bandwidth: 80 Gbps

A.1.2 Configurations

The ONS 15454 can be configured for these dense wavelength division multiplexing (DWDM) topologies:

  • Hubbed rings
  • Multihubbed rings
  • Point-to-point
  • Linear
  • Linear with optical add/drop multiplexing (OADM)
  • Hybrid terminal node
  • Hybrid OADM node
  • Hybrid line amplifier node

A.1.3 Cisco Transport Controller

CTC, the ONS 15454 craft interface software, has these specifications:

  • 10BaseT Ethernet
  • TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE card access: RJ-45 connector
  • Backplane access: LAN pin field (ANSI only)
  • Front Mount Electrical Connection (FMEC) access: LAN connector on MIC-C/T/P faceplate (ETSI only)

A.1.4 External LAN Interface

The ONS 15454 external LAN interface has these specifications:

  • 10BaseT Ethernet
  • Backplane access: LAN pin field (ANSI only)
  • FMEC access: LAN connector on MIC-C/T/P faceplate (ETSI only)

A.1.5 TL1 Craft Interface

The ONS 15454 TL1 craft interface has these specifications:

  • Speed: 9600 bps
  • TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector
  • Backplane access: CRAFT pin field (ANSI only)

A.1.6 Modem Interface

The ONS 15454 modem interface has these specifications:

  • Hardware flow control
  • TCC2/TCC2P/TCC3/TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector

A.1.7 Alarm Interface

The ONS 15454 alarm interface has these specifications:

  • ETSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

FMEC access: 62-Pin DB connector on MIC-A/P faceplate

Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA

Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA

  • ANSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

Backplane access: Alarm pin fields

Alarm contacts: 0.045 mm, –48 V, 50 mA

A.1.8 EIA Interface (ANSI only)

The ONS 15454 electrical interface assembly (EIA) interface has these specifications:

  • SMB: AMP #415504-3 75-ohm, 4-leg connectors
  • BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King or ITT are also compatible)
  • AMP Champ: AMP#552246-1 with #552562-2 bail locks

A.1.9 BITS Interface (ANSI only)

The ONS 15454 building integrated timing supply (BITS) interface has these specifications:

  • 2 DS-1 BITS inputs
  • 2 derived DS-1 outputs
  • Backplane access: BITS pin field

A.1.10 System Timing

The ONS 15454 ANSI has these system timing specifications:

  • Stratum 3 per Telcordia GR-253-CORE
  • Free running accuracy: +/– 4.6 ppm
  • Holdover stability: 3.7 x 10–7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

The ONS 15454 ETSI has these system timing specifications:

  • Stratum 3E, per ITU-T G.813
  • Free running accuracy: +/– 4.6 ppm
  • Holdover stability: 3.7 exp –7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

A.1.11 System Power

The ONS 15454 ANSI has these power specifications:

  • Nominal Input Voltage: –48 VDC
  • Power consumption: Configuration dependent; 55 W (fan tray only)
  • Power requirements:

Nominal: –48 VDC

Input Voltage Range: –40.5 to –57.0 VDC

  • Power terminals: #6 Lug
  • ANSI shelf fusing: 100–A fuse panel (minimum 30 A fuse per shelf)
    HD shelf fusing: 100–A fuse panel (minimum 30 A fuse per shelf)

The ONS 15454 ETSI has these power specifications:

  • Nominal Input Voltage: –48 VDC
  • Power consumption: Configuration dependent; 53 W (fan tray only)
  • Power requirements:

Nominal: –48 VDC

Input Voltage Range: –40.5 to –57.0 VDC

  • Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates)
  • Fusing: 100 A fuse panel; minimum 30 A fuse per shelf

A.1.12 Fan Tray

The following table lists power requirements for the fan-tray assembly.

 

Table A-1 Fan Tray Assembly Power Requirements

Fan Tray Assembly
Watts
Amps
BTU/Hr
FTA2

53

1.21

198

FTA3 -T

86.4

1.8

295

15454E-CC-FTA/15454-CC-FTA

115

2.4

393

A.1.13 System Environmental Specifications

The ONS 15454 ANSI has these environmental specifications:

  • Operating temperature:

C-Temp: 32 to +131 degrees Farenheit (0 to +55 degrees Celsius)

I-Temp: –40 to +139 degrees Farenheit (–40 to +65 degrees Celsius)

  • Operating humidity: 5 to 95 percent, noncondensing

The ONS 15454 ETSI has the following environmental specifications:

  • Operating temperature: 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)
  • Operating humidity: 5 to 95 percent, noncondensing

A.1.14 Dimensions

The ONS 15454 ANSI shelf assembly has these dimensions:

  • Height: 18.5 in. (40.7 cm)
  • Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached
  • Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)
  • Weight: 55 lb (24.947 kg) empty

The ONS 15454 ETSI shelf assembly has the following dimensions:

  • Height: 616.5 mm (24.27 in.)
  • Width: 535 mm (17 in.) without mounting ears attached
  • Depth: 280 mm (11.02 in.)
  • Weight: 26 kg empty (57.3 lb)

A.2 ONS 15454 M2 Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.

A.2.1 Bandwidth

The ONS 15454 M2 has these bandwidth specifications (depending on the applications):

  • Total bandwidth: 200 Gbps
  • Data plane bandwidth: 100 Gbps per slot

A.2.2 Configurations

The ONS 15454 M2 can be configured for these dense wavelength division multiplexing (DWDM) topologies:

  • Hubbed rings
  • Multihubbed rings
  • Point-to-point
  • Linear
  • Linear with optical add/drop multiplexing (OADM)
  • Line amplifier node
  • Transponder Shelf
  • Layer 2 aggregation shelf

A.2.3 Cisco Transport Controller

CTC, the ONS 15454 M2 craft interface software, has these specifications:

  • 10/100BaseT Ethernet
  • TNC/TNCE/TSC/TSCE card access: RJ-45 LAN connector on the controller front plate

A.2.4 External LAN Interface for EMS

The ONS 15454 M2 external LAN interface has these specifications:

  • 10/100BaseT Ethernet located on the power module

A.2.5 TL1 Craft Interface

The ONS 15454 M2 TL1 craft interface has these specifications:

  • TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector

A.2.6 Modem Interface

The ONS 15454 M2 modem interface has these specifications:

  • Hardware flow control
  • TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector

A.2.7 Alarm Interface

The ONS 15454 M2 does not support alarm interface.

A.2.8 Passive Unit Remote Inventory

The ONS 15454 M2 provides 1 standard USB port located on the power module to retrieve the passive units inventory data.

A.2.9 BITS Interface

The ONS 15454 M2 building integrated timing supply (BITS) interface has these specifications:

  • 1 DS-1 BITS inputs wire wrap for ANSI applications
  • 1 derived DS-1 outputs wire wrap for ANSI applications
  • 1 E1 BITS input DIN-1.0/2.3 for ETSI applications
  • 1 E1 BITS output DIN-1.0/2.3 for ETSI applications

A.2.10 System Timing

The ONS 15454 M2 for ANSI has these timing specifications:

  • Stratum 3 per Telcordia GR-253-CORE
  • Free running accuracy: +/- 4.6 ppm
  • Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

The ONS 15454 M2 for ETSI has the following system timing specifications:

  • Stratum 3, per ITU-T G.813
  • Free running accuracy: +/- 4.6 ppm
  • Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

A.2.11 System Power

The ONS 15454 M2 has these AC power specifications:

  • Input Voltage: 100V - 240V AC (+/- 10%)
  • Power consumption: Configuration dependent; 35 W (Fan Tray and LCD)
  • Power terminals standard 3 pole AC connector
  • For an AC power supply, the fuse rating must not exceed 10A, 15A, or 20A depending on the standard in various countries. For North America, the branch circuit protection must be rated 20A
  • Total maximum power consumption of 350W with ancillaries, controllers and linecards

The ONS 15454 M2 has these DC power specifications:

  • Nominal Input Voltage: –48 VDC
  • Power consumption: Configuration dependent; 35 W (Fan Tray and LCD)
  • Power requirements:

Nominal: –48 VDC

Input Voltage Range: -40.5 to -57.6 VDC

  • Power terminals: DSUB 2 poles for ETSI applications and terminal block double pole for ANSI applications
  • External fuse must not exceed 15A
  • Total maximum power consumption of 450W with ancillaries, controllers and linecards

A.2.12 Fan Tray

The following table lists power requirements for the fan-tray assembly.

Table A-2 Fan-Tray Assembly Power Requirements

Fan Tray Assembly
Watts
Amps
BTU/Hr

15454-M2-FTA

35

1

120

15454-M2-FTA2

40

1

135

A.2.13 System Environmental Specifications

The ONS 15454 M2 for ANSI environment has these specifications:

  • Operating temperature: 23 to +131 degrees Farenheit (-5 to +55 degrees Celsius)
  • Operating humidity: 5 to 95 percent, noncondensing

The ONS 15454 M2 for ETSI environment has the following specifications:

  • Operating temperature: 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)
  • Operating humidity: 5 to 95 percent, noncondensing

A.2.14 Dimensions

The ONS 15454 M2 shelf assembly has these dimensions:

  • Height: 3.5 inches (88.9 mm)
  • Width: 19 or 23 inches (482.6 or 584.2 mm) with mounting ears attached
  • Depth: 11.1 inches (281.94 mm)
  • Weight:

11.02 pounds (5 kg) with preinstalled air filter and no cards installed

15.40 pounds (6.82 kg) with the power module, fan-tray assembly and air filter installed but with no cards.

A.3 ONS 15454 M6 Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and ONS 15454 M6 shelf dimensions.

The ONS 15454 M6 shelf is compliant with the ETS 300-119-4 standard.

A.3.1 Bandwidth

The ONS 15454 M6 has the following bandwidth specifications (depending on the applications):

  • Total bandwidth: 400 Gbps
  • Data plane bandwidth: 100 Gbps per slot

A.3.2 Configurations

The ONS 15454 M6 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:

  • Hubbed rings
  • Multihubbed rings
  • Point-to-point
  • Linear
  • Linear with optical add/drop multiplexing (OADM)
  • Hybrid terminal node
  • Hybrid OADM node
  • Hybrid line amplifier node
  • Transponder Shelf
  • Layer 2 aggregation shelf

A.3.3 Cisco Transport Controller

CTC, the ONS 15454 M6 craft interface software, has the following specifications:

  • 10/100BaseT Ethernet
  • TNC/TNCE/TSC/TSCE card access: RJ-45 LAN connector on the controller front plate
  • Shelf access: RJ-45 LAN Connector located on the ECU or ECU2

A.3.4 External LAN Interface for EMS

The ONS 15454 M6 external LAN interface has the following specification:

  • 10/100BaseT Ethernet located on the ECU or ECU2 and supports:

10/100 Mbps full duplex

Auto detection

A.3.5 TL1 Craft Interface

The ONS 15454 M6 TL1 craft interface has the following specifications:

  • Speed: 9600 bps
  • TNC/TNCE/TSC/TSCE access: EIA/TIA-232 DB-9 type connector
  • An alternative RJ-45 LAN connector on TNC/TNCE/TSC/TSCE or ECU or ECU2

A.3.6 Modem Interface

The ONS 15454 M6 modem interface has the following specifications:

  • Hardware flow control
  • TNC/TNCE/TSC/TSCE: EIA/TIA-232 DB-9 type connector

A.3.7 Alarm Interface

The ONS 15454 M6 alarm interface has the following specifications:

  • 2 SCSI Connectors located on the ECU or ECU2
  • Visual: Critical, Major, Minor, Remote
  • Audible: Critical, Major, Minor, Remote
  • Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA
  • Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA

A.3.8 Passive Unit Remote Inventory

The ONS 15454 M6 provide 12 standard USB ports located on the ECU or ECU2 to retrieve the inventory data from the passive units.

A.3.9 BITS Interface

The ONS 15454 M6 building integrated timing supply (BITS) interface has the following specifications:

  • 2 T1 BITS inputs wire wrap for ANSI applications
  • 2 derived T1 outputs wire wrap for ANSI applications
  • 2 E1 BITS input DIN-1.0/2.3 for ETSI applications
  • 2 E1 BITS output DIN-1.0/2.3 for ETSI applications

A.3.10 System Timing

The ONS 15454 M6 for ANSI has the following system timing specifications:

  • Stratum 3 per Telcordia GR-253-CORE
  • Free running accuracy: +/- 4.6 ppm
  • Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

The ONS 15454 M6 for ETSI has the following system timing specifications:

  • Stratum 3, per ITU-T G.813
  • Free running accuracy: +/- 4.6 ppm
  • Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
  • Reference: External BITS, line, internal

A.3.11 System Power

A.3.11.1 AC Power Specifications

The ONS 15454 M6 has these AC power specifications:

  • Shelf power consumption: Configuration dependent; 130 W (Fan Tray, LCD, and ECU module).
  • Power terminals standard 3-pole AC connector.
  • Fuse rating for an AC power supply must not exceed 10 A, 15 A, or 20 A depending on the standard in various countries. For North America, the branch circuit protection must be rated 20 A.

The following table lists power specifications of the AC power modules for the ONS 15454 M6 shelf.

Table A-3 ONS 15454 M6 AC Power Specifications

AC Power Module
Input Voltage Range
Output Voltage
Load

15454-M6-AC

100–120 V AC (US nominal range), 60Hz

-48.0 V DC

900 W

200–250 V AC (Europe nominal range), 50Hz

-48.0 V DC

900 W

15454-M6-AC2

100–120 V AC (US nominal range), 60Hz

-48.0 V DC

1200 W

200–250 V AC (Europe nominal range), 50Hz

-48.0 V DC

1500 W

 

A.3.11.2 DC Power Specifications

The following table lists power specifications of the DC power modules for the ONS 15454 M6 shelf.

Table A-4 ONS 15454 M6 DC Power Specifications

DC Power Module
Rating
Nominal Voltage
Current
Input Voltage Range
Maximum Load

15454-M6-DC

30 Amp

–48 VDC

30 Amp

–40.5 to –57.6 VDC

1440 W

–60 VDC

24 Amp

–50 to –72 VDC

15454-M6-DC20

20 Amp

–48 VDC

20 Amp

–40.5 to –57.6 VDC

960 W

–60 VDC

16 Amp

–50 to –72 VDC

15454-M6-DC40

40 Amp

-48 VDC

40 Amp

–40.5 to –57.6 VDC

1920 W

-60 VDC

32 Amp

–50 to –72 VDC


Note When the ONS 15454 M6 shelf is powered at –60 VDC (nominal), only these cards can be installed: TNC, OPT-AMP-C, OPT-AMP-17-C, OPT-EDFA-17, and OPT-EDFA-24 cards, and the 15454-M6-ECU-60 card.


  • 15454-M6-DC, 15454-M6-DC20, and 15454-M6-DC40 shelf power consumption (configuration dependent):

130 W with 15454-M6-FTA Fan Tray, LCD, and ECU module

140 W with 15454-M6-FTA2 Fan Tray, LCD, and ECU module

  • Power terminals—DSUB 3 poles for ETSI applications and terminal block, double pole for ANSI applications.
  • External fuse must not exceed 40 A

A.3.11.3 Power Calculation

For the ONS 15454 M6 shelf that is powered by the 15454-M6-DC20 or the 15454-M6-DC40 power module, the controller card calculates the total power consumption of the shelf, which is displayed in the Provisioning > Power Monitor tab in CTC. For the power calculation to function properly ensure that:

  • There is no MEA alarm on any card.
  • The LCD module is properly plugged-in.

The total power consumption value for the shelf is computed by aggregating the power consumption values of individual cards and ancillary units installed or pre-provisioned in the shelf. The following table lists the power consumption values of the line cards that are considered for power calculation.

Table A-5 Line Card Power Consumption Values

Card
Actual Power (Watts) 1
Typical Power (Watts) 2

10GE_XP

79

40

10X10G-LC

70

25

100G-LC-C

150

90

32DMX

50

30

32DMX-O

50

30

32MUX

50

30

32WSS

65

20

4MD

50

30

40-DMX-C

50

30

40E-TXP-C

130

50

40E-MXP-C

143

50

40G-MXP

112

50

40G-MXP-C

143

50

40G-TXP

99

50

40G-TXP-C

130

50

40-MUX-C

50

30

40-SMR1-C

60

12

40-SMR2-C

70

12

40WSS-C

79

32

40WSS-CE

79

32

40-WXC-C

50

30

40-WXC-L

50

30

80-WXC-C

100

30

AD-1C

50

30

AD-2C

50

30

AD-4C

50

30

ADM-10G

160

20

AR_MXP

74

35

AR_XP

74

35

AR_XPE

74

35

C-TCDU

50

30

CFP-LC

140

40

CPT-PTM-4

130

60

CPT-PTF-4

200

80

F-TCDU

50

30

GE_XP

79

40

MS-ISC-100T

69

20

MXP_2.5G_10E

50

30

MXP_2_5G_10E_UT2

50

30

MXP_2.5G_10G

50

30

MXP_MR_10DME

74

40

MXP_MR_10DME_UT3

74

40

MXP_MR_2.5G

60

35

MXPP_MR_2.5G

60

38

OPT-AMP-17-C

50

30

OPT-AMP-C

50

30

OPT-BST

50

30

OPT-BST-E

50

30

OPT-EDFA-17

50

30

OPT-EDFA-24

50

30

OPT-PRE

50

30

OPT-RAMP-C

55

11

OPT-RAMP-CE

58

11

OSC-CSM

27

15

OTU2-XP

70

37

PSM

50

30

RAMAN-COP

90

12

RAMAN-CTP

90

12

TNC and TNCE

62

52

TSC and TSCE

55

46

TXP_MR_10E

50

30

TXP_MR_10EX

53

30

TXP_MR_10E_UT2

50

30

TXP_MR_10G

50

30

TXP_MR_2.5G

50

30

TXPP_MR_10EX

53

30

TXPP_MR_2.5G

50

30

WSE

74

40

100G-CK-C

153

93

100ME-CKC

153

93

1.Power consumed by a line card once it has boot-up.

2.Power consumed by a line card when it is physically present in the shelf but deleted in CTC, or when it has not boot-up due to PWR-CON-LMT alarm after installation or pre-provisioning.

During power calculation, certain wattage is always reserved for ancillary units like the ECU, fan tray, and standby controller card, irrespective of whether they are present in the shelf or not. The reserved power for the ONS 15454 M6 shelf with a TNC or TNC-E controller card is 284 W, and for the TSC or TSC-E controller card it is 270 W.


Note In the shelf powered by the15454-M6-DC20 power module, a new line card will not boot if it causes the power consumption of the shelf to exceed 960 W. The PWR-CON-LMT alarm is raised in the Alarms tab in CTC when the installation or pre-provisioning of a card causes the power consumption to exceed 960 W. You must uninstall and deprovision the card that causes the PWR-CON-LMT alarm.



Note In the shelf powered by the15454-M6-DC40 power module, a new line card will not boot if it causes the power consumption of the shelf to exceed 1920 W. The PWR-CON-LMT alarm is raised in the Alarms tab in CTC when the installation or pre-provisioning of a card causes the power consumption to exceed 1920 W. You must uninstall and deprovision the card that causes the PWR-CON-LMT alarm.


A.3.12 Fan Tray

The following table lists power requirements for the fan-tray assembly.

Table A-6 Fan-Tray Assembly Power Requirements

Fan Tray Assembly
Watts
Amps
BTU/Hr

15454-M6-FTA

120

3

410

15454-M6-FTA2

130

3.5

445

A.3.13 System Environmental Specifications

The ONS 15454 M6 for ANSI environment has these specifications:

  • Operating temperature: 23 to +131 degrees Farenheit (-5 to +55 degrees Celsius)
  • Operating humidity: 5 to 95 percent, noncondensing

The ONS 15454 M6 for ETSI environment has these specifications:

  • Operating temperature: 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)
  • Operating humidity: 5 to 95 percent, noncondensing

A.3.14 Dimensions

The ONS 15454 M6 shelf assembly has these dimensions:

  • Height: 10.4 inches (264.16 mm)
  • Width: 19 or 23 inches (482.6 or 584.2 mm) with mounting ears attached
  • Depth: 11.1 inches (281.94 mm)
  • Weight:

23.55 pounds (10.680 kg) with preinstalled air filter and no cards installed

40.12 pounds (18.2 kg) with all the ancillary units (2 DC power modules, ECU or ECU2, fan-tray assembly and air filter) installed but with no cards.