Cisco ONS SDH TL1 Command Guide, Release 9.8.x
Chapter 11, ED Commands
Downloads: This chapterpdf (PDF - 1.71MB) The complete bookPDF (PDF - 11.06MB) | Feedback

Table of Contents

ED Commands

11.1 ED-CPS

ED Commands

This chapter provides edit (ED) commands for the Cisco ONS 15454 SDH, Cisco ONS 15454 M2, and Cisco ONS 15454 M6.


NoteAll commands supported on the Cisco ONS 15454 SDH platform are also supported on Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.


11.1 ED-CPS

This command can be used to modify Control Plane Service parameter. The user needs to specify only the source port to identify the CPS. If the CPS is of type ADD 2WAY, both src AIDs have to be specified

 
Usage Guidelines

  • If the AID is invalid, an IIAC (invalid AID) error message is returned. The following AIDs are supported:

CLIENT cps type support FAC and VFAC AID type.

TRUNK cps type support CHAN AID type.

ADD cps type support CHAN, PCHAN and LINEWL AID type.

  • The ALL AID is invalid for this command
  • In case of 1WAY, unidirectional connection, SRC and DST are single AIDs. In case of 2WAY, bidirectional connection, SRC and DST are double AIDs. However, in case of CLIENT or TRUNK cpstype, src and dst are single AID and the connection is of type 2WAY because of bidirectional ports hence this rule is not applicable.
  • If the RESTTYPE is REVERT, it is required to set the REVERTMODE and SOAK parameters.
  • If the RESTTYPE is REVERT, it is mandatory to set the REVERTMODE parameter as MANUAL or AUTO.
  • SOAK time is mandatory if the REVERTMODE parameter is set to MANUAL or AUTO.

Category

DWDM

Security

Provisioning

Input Format

ED-CPS[:<TID>]:<SRC>:<CTAG>[:::CKTID=<CKTID>],[VALMODE=<VALMODE>],[VALZONE=<VALZONE>],[VALMODESEC=<VALMODESEC>],[VALZONESEC=<VALZONESEC>],[CMDMDE=<CMDMDE>],[RESTTYPE=<RESTTYPE>],[REVERTMODE=<REVERTMODE>],[SOAK=<HH-MM-SS>][:<PST>[,<SST>]];

Input Example

ED-CPS::PCHAN-1-1-RX&PCHAN-1-1-TX:8:::CKTID=twoway_add-passive,VALMODE=FULL,VALZONE=GREEN:;

ED-CPS::CHAN-1-2-2:1:::RESTTYPE=REVERT,REVERTMODE=MANUAL,SOAK=00-00-10;

Input Parameters

<SRC>

Source access identifier from the “ALL” section. Listable.

  • 1WAY

A unidirectional connection from a source port to a destination port. In 1WAY wavelength connection only one AID is requested

  • 2WAY

A bidirectional connection between the two ports. CLIENT or TRUNK 2WAY is requested together with one AID.

<CKTID>

(Optional) Circuit identification parameter contains the Common Language Circuit ID or other alias of the circuit being provisioned. Does not contain blank spaces. CKTID is a string of ASCII characters. The maximum length of CKTID can be 48.

<VALMODE>

Identifies the validation mode.

  • NONE

No Optical validation is performed.

  • FULL

The optical validation is performed as indicated in VALZONE parameter.

<VALZONE>

Identifies the validation operate zone.

  • UNKNOWN

Not evaluated

  • GREEN

Margin > 3 sigma

  • YELLOW

1 < margin < 3 sigma

  • ORANGE

0 < margin < 1 sigma

  • RED

-3 < margin < 0 sigma

  • OUT

Margin < -3 sigma

<VALMODESEC>

Identifies the validation mode for secondary circuit.

<VALZONESEC>

Identifies the validation operate zone for secondary circuit.

<RESTTYPE>

Specifies the restoration type on CPS circuit or UNI configuration. Parameter type is RESTTYPE.

  • NONE

Restore type is not specified.

  • RESTORE

Only restoration is allowed. The circuit is not revertible.

  • REVERT

The circuit is revertible, manually or automatically.

<REVERTMODE>

Specifies the revertive mode type. Paraneter type is REVERTMODE.

  • AUTO

Circuit is automatically revertible after the soak time expires.

  • MANUAL

Manually revert the circuit.

  • NONE

Not revertible.

<SOAK>

This is the soak time specified in HH-MM-SS format. After the soak time expires, if the revertive mode is AUTO, the circuit reverts automatically. If revertive mode is MANUAL, the soak time is ignored.

11.2 ED-<GIGE_TYPE>

(Cisco ONS 15454 SDH) The Edit 10GIGE, 100GIGE, 40GIGE, or GIGE (ED-<GIGE_TYPE>) command edits Ethernet facility attributes. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

  • The SYNCMSG, SENDDUS, ADMSSM, and ESMC parameters are applicable only for AR-MXP and AR-XP cards.
  • The following parameters apply only to ED-GIGE; ADMINSTATE, LINKSTATE, MTU, FLOWCTRL, AUTONEG, HIWMRK, LOWMRK, DUPLEX, SPEED, and SOAK.
  • The MACADDR parameter is applicable for ED-10GIGE only.
  • The ENCAP parameter applies to 10GIGE SFP+ ports on 10x10G-LC only.
  • In the CFP-TXP mode, the ED-<GIGE_TYPE> is applicable for SOAK, SYNCMSG, and SENDDUS paramters on the CFP-LC card on the VFAC AID.
  • In the CFP-TXP mode, the ED-<GIGE_TYPE> is applicable for MTU and MACADDR paramters on the 100G-LC-C virtual ports on VCFAC AID.
  • Autonegotiation parameters such as AUTONEG, DUPLEX, SPEED, ACTDUPLEX, and ACTSPEED are not applicable for 10GIGE on AR-XPE, AR-XP, AR-MXP cards and GIGE on AR-XPE card only.

Category

Ports

Security

Provisioning

Input Format

ED-GIGE:[<TID>]:<AID>:<CTAG>:::[ADMINSTATE=<ADMINSTATE>],[LINKSTATE=<LINKSTATE>],[MTU=<MTU>],[MFS=<MFS>],[FLOW=<FLOW>],[FLOWCTRL=<FLOWCTRL>],[AUTONEG=<AUTONEG>],[HIWMRK=<INT>],[LOWMRK=<INT>],[OPTICS=<OPTICS>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[MACADDR=<MACADDR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>],[SQUELCH=<SQUELCH>],[CIR=<CIR>],[CBS=<CBS>],[EBS=<EBS>],[LIENABLE=<LIENABLE>],[LITIMER=<LITIMER>],[ENCAP=<ENCAP>],[PAUSEFRAME=<PAUSEFRAME>],[CLNTDST=<CLNTDST>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[ADMSSM=<ADMSSM>],[ESMC=<ESMC>],<PAUSEFRAME>],[EXPDUPLEX=<EXPDUPLEX>],[EXPSPEED=<EXPSPEED>],[SELECTIVEAUTO=<SELECTIVEAUTO>],[SQUELCHMODE=<SQUELCHMODE>]:[<PST>[,<SST>]];

Input Example

ED-GIGE:PETALUMA:FAC-1-1:123:::ADMINSTATE=DOWN,LINKSTATE=DOWN,MTU=1548,
FLOWCTRL=NONE,AUTONEG=Y,HIWMRK=485,LOWMRK=25,OPTICS=1000_BASE_LX,
DUPLEX=AUTO,SPEED=AUTO,NAME="GIGE PORT",CMDMDE=FRCD,
MACADDR=00-0E-AA-BB-CC-FF,FREQ=1550,LOSSB=SX,SOAK=32,LIENABLE=Y,
LITIMER=200:IS,AINS;

Table 11-1 ED-<GIGE_TYPE> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the FACILITY. The AR-MXP, AR-XP, and AR-XPE cards use the VFAC Access Identifier.

<ADMINSTATE>

(Optional) The parameter type is UP_DOWN, which indicates an up or down value.

  • DOWN

Down

  • UP

Up

<LINKSTATE>

(Optional) The parameter type is UP_DOWN, which indicates an up or down value.

  • DOWN

Down

  • UP

Up

<MTU>

(Optional) Maximum transport unit. The parameter type is MTU_TYPE, which indicates the maximum transport unit used by an Ethernet card. Defaults to 9600.

  • 10004

10004. Indicates jumbo size.

  • 1500

1500

  • 1548

1548

  • 9600

9600. Indicates jumbo size.

  • 64

64

  • 9700

9700. Indicates jumbo size.

<MFS>

(Optional) Maximum frame size. The parameter type is MFS_TYPE, which is the maximum frame size used by an Ethernet card.

  • 1548

Normal frame size

  • JUMBO

Jumbo frame size

<FLOWCTRL>

(Optional) Flow control. The parameter type is FLOW, which indicates the type of flow control that has been negotiated for an Ethernet port. Defaults to NONE.

  • ASYMMETRIC

Asymmetric flow control

  • ASYMMETRIC_LOCAL

Asymmetric local flow control

  • NONE

No flow control

  • PASSTHRU

Passthrough flow control

  • SYMMETRIC

Symmetric flow control

<AUTONEG>

(Optional) Autonegotiation. The parameter is ON_OFF, which disables or enables an attribute. Defaults to Y.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<HIWMRK>

(Optional) High water mark. HIWMRK is an integer. Defaults to 485.

<LOWMRK>

(Optional) Low water mark. LOWMRK is an integer. Defaults to 25.

<OPTICS>

(Optional) The parameter is OPTICS, which indicates the type of Gigabyte Ethernet optics being used.

  • 1000_BASE_CX

1000BaseCX

  • 1000_BASE_LX

1000BaseLX

  • 1000_BASE_SX

1000BaseSX

  • 1000_BASE_T

1000BaseT

  • 1000_BASE_ZX

1000BaseZX

  • 100_BASE_BX_D

100BaseBX_D

  • 100_BASE_BX_U

100BaseBX_U

  • 100_BASE_FX

100BaseFX

  • 100_BASE_LX

100BaseLX

  • CWDM_1470

Coarse wavelength division multiplexing (CWDM) 1470

  • CWDM_1490

CWDM 1490

  • CWDM_1510

CWDM 1510

  • CWDM_1530

CWDM 1530

  • CWDM_1550

CWDM 1550

  • CWDM_1570

CWDM 1570

  • CWDM_1590

CWDM 1590

  • CWDM_1610

CWDM 1610

  • ITU_100G_1530_33

ITU-100G 1530.33

  • ITU_100G_1531_12

ITU-100G 1531.12

  • ITU_100G_1531_90

ITU-100G 1531.90

  • ITU_100G_1532_68

ITU-100G 1532.68

  • ITU_100G_1534_25

ITU-100G 1534.25

  • ITU_100G_1535_04

ITU-100G 1535.04

  • ITU_100G_1535_82

ITU-100G 1535.82

  • ITU_100G_1536_61

ITU-100G 1536.61

  • ITU_100G_1538_19

ITU-100G 1538.19

  • ITU_100G_1538_98

ITU-100G 1538.98

  • ITU_100G_1539_77

ITU-100G 1539.77

  • ITU_100G_1540_56

ITU-100G 1540.56

  • ITU_100G_1542_14

ITU-100G 1542.14

  • ITU_100G_1542_94

ITU-100G 1542.94

  • ITU_100G_1543_73

ITU-100G 1543.73

  • ITU_100G_1544_53

ITU-100G 1544.53

  • ITU_100G_1546_12

ITU-100G 1546.12

  • ITU_100G_1546_92

ITU-100G 1546.92

  • ITU_100G_1547_72

ITU-100G 1547.72

  • ITU_100G_1548_51

ITU-100G 1548.51

  • ITU_100G_1550_12

ITU-100G 1550.12

  • ITU_100G_1550_92

ITU-100G 1550.92

  • ITU_100G_1551_72

ITU-100G 1551.72

  • ITU_100G_1552_52

ITU-100G 1552.52

  • ITU_100G_1554_13

ITU-100G 1554.13

  • ITU_100G_1554_94

ITU-100G 1554.94

  • ITU_100G_1555_75

ITU-100G 1555.75

  • ITU_100G_1556_55

ITU-100G 156.55

  • ITU_100G_1558_17

ITU-100G 1558.17

  • ITU_100G_1558_98

ITU-100G 1558.98

  • ITU_100G_1559_79

ITU-100G 1559.79

  • ITU_100G_1560_61

ITU-100G 1560.61

  • UNKNOWN

Unknown

  • UNPLUGGED

Unplugged

<DUPLEX>

(Optional) The parameter is ETHER_DUPLEX, which indicates duplex mode. Defaults to AUTO.

  • AUTO

Auto mode

  • FULL

Full mode

  • HALF

Half mode

<SPEED>

(Optional) The parameter type is ETHER_SPEED, which indicates Ethernet speed. Defaults to AUTO.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 10_MBPS

10 Megabits per second

  • 1_GBPS

1 Gigabit per second

  • 40_GBPS

40 Gigabit per second

  • AUTO

Automatic

  • AUTO_FDX

Enable auto negotiation with full duplex.

<NAME>

(Optional) Port name. NAME is a string. Defaults to NULL. Maximum length is 32 characters.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state where the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that might make the command fail.

<MACADDR>

(Optional) MACADDR is a string. Defaults to NULL. Maximum length is 18 characters.

<FREQ>

(Optional) The parameter type is OPTICAL_WLEN, which indicates the optical wavelength.

  • 1310

Wavelength 1310

  • 1470

Wavelength 1470

  • 1490

Wavelength 1490

  • 1510

Wavelength 1510

  • 1528.77

Wavelength 1528.77

  • 1529.16

Wavelength 1529.16

  • 1529.55

Wavelength 1529.55

  • 1529.94

Wavelength 1529.94

  • 1530

Wavelength 1530

  • 1530.33

Wavelength 1530.33

  • 1530.73

Wavelength 1530.73

  • 1531.12

Wavelength 1531.12

  • 1531.51

Wavelength 1531.51

  • 1531.90

Wavelength 1531.90

  • 1532.29

Wavelength 1532.29

  • 1532.68

Wavelength 1532.68

  • 1533.07

Wavelength 1533.07

  • 1533.47

Wavelength 1533.47

  • 1533.86

Wavelength 1533.86

  • 1534.25

Wavelength 1534.25

  • 1534.64

Wavelength 1534.64

  • 1535.04

Wavelength 1535.04

  • 1535.43

Wavelength 1535.43

  • 1535.82

Wavelength 1535.82

  • 1536.22

Wavelength 1536.22

  • 1536.61

Wavelength 1536.61

  • 1537

Wavelength 1537

  • 1537.40

Wavelength 1537.40

  • 1537.79

Wavelength 1537.79

  • 1538.19

Wavelength 1538.19

  • 1538.58

Wavelength 1538.58

  • 1538.98

Wavelength 1538.98

  • 1539.37

Wavelength 1539.37

  • 1539.77

Wavelength 1539.77

  • 1540.16

Wavelength 1540.16

  • 1540.56

Wavelength 1540.56

  • 1540.95

Wavelength 1540.95

  • 1541.35

Wavelength 1541.35

  • 1541.75

Wavelength 1541.75

  • 1542.14

Wavelength 1542.14

  • 1542.35

Wavelength 1542.35

  • 1542.54

Wavelength 1542.54

  • 1542.94

Wavelength 1542.94

  • 1543.33

Wavelength 1543.33

  • 1543.73

Wavelength 1543.73

  • 1544.13

Wavelength 1544.13

  • 1544.53

Wavelength 1544.53

  • 1544.92

Wavelength 1544.92

  • 1545.30

Wavelength 1545.30

  • 1545.32

Wavelength 1545.32

  • 1545.72

Wavelength 1545.72

  • 1546.12

Wavelength 1546.12

  • 1546.52

Wavelength 1546.52

  • 1546.92

Wavelength 1546.92

  • 1547.32

Wavelength 1547.32

  • 1547.72

Wavelength 1547.72

  • 1548.12

Wavelength 1548.12

  • 1548.51

Wavelength 1548.51

  • 1548.92

Wavelength 1548.92

  • 1549.32

Wavelength 1549.32

  • 1549.71

Wavelength 1549.71

  • 1550

Wavelength 1500

  • 1550.12

Wavelength 1550.12

  • 1550.52

Wavelength 1550.52

  • 1550.92

Wavelength 1550.92

  • 1551.32

Wavelength 1551.32

  • 1551.72

Wavelength 1551.72

  • 1552.12

Wavelength 1552.12

  • 1552.52

Wavelength 1552.52

  • 1552.93

Wavelength 1552.93

  • 1553.30

Wavelength 1553.30

  • 1553.33

Wavelength 1553.33

  • 1553.73

Wavelength 1553.73

  • 1554.13

Wavelength 1554.13

  • 1554.13

Wavelength 1554.13

  • 1554.94

Wavelength 1554.94

  • 1555.34

Wavelength 1555.34

  • 1555.75

Wavelength 1555.75

  • 1556.15

Wavelength 1556.15

  • 1556.55

Wavelength 1556.55

  • 1556.96

Wavelength 1556.96

  • 1557.36

Wavelength 1557.36

  • 1557.77

Wavelength 1557.77

  • 1558.17

Wavelength 1558.17

  • 1558.58

Wavelength 1558.58

  • 1558.98

Wavelength 1558.98

  • 1559.39

Wavelength 1559.39

  • 1559.79

Wavelength 1559.79

  • 1560.20

Wavelength 1560.20

  • 1560.61

Wavelength 1560.61

  • 1561.01

Wavelength 1561.01

  • 1561.42

Wavelength 1561.42

  • 1561.83

Wavelength 1561.83

  • 1562.23

Wavelength 1562.23

  • 1562.64

Wavelength 1562.64

  • 1563.05

Wavelength 1563.05

  • 1563.45

Wavelength 1563.45

  • 1563.86

Wavelength 1563.86

  • 1564.27

Wavelength 1564.27

  • 1564.68

Wavelength 1564.68

  • 1565.09

Wavelength 1565.09

  • 1565.50

Wavelength 1565.50

  • 1565.90

Wavelength 1565.90

  • 1566.31

Wavelength 1566.31

  • 1566.72

Wavelength 1566.72

  • 1570

Wavelength 1570

  • 1570.83

Wavelength 1570.83

  • 1571.24

Wavelength 1571.24

  • 1571.65

Wavelength 1571.65

  • 1572.06

Wavelength 1572.06

  • 1572.48

Wavelength 1572.48

  • 1572.89

Wavelength 1572.89

  • 1573.30

Wavelength 1573.30

  • 1573.71

Wavelength 1573.71

  • 1574.13

Wavelength 1574.13

  • 1574.54

Wavelength 1574.54

  • 1574.95

Wavelength 1574.95

  • 1575.37

Wavelength 1575.37

  • 1575.78

Wavelength 1575.78

  • 1576.20

Wavelength 1576.20

  • 1576.61

Wavelength 1576.61

  • 1577.03

Wavelength 1577.03

  • 1577.44

Wavelength 1577.44

  • 1577.86

Wavelength 1577.86

  • 1578.27

Wavelength 1578.27

  • 1578.69

Wavelength 1578.69

  • 1579.10

Wavelength 1579.10

  • 1579.52

Wavelength 1579.52

  • 1579.93

Wavelength 1579.93

  • 1580.35

Wavelength 1580.35

  • 1580.77

Wavelength 1580.77

  • 1581.18

Wavelength 1581.18

  • 1581.60

Wavelength 1581.60

  • 1582.02

Wavelength 1582.02

  • 1582.44

Wavelength 1582.44

  • 1582.85

Wavelength 1582.85

  • 1583.27

Wavelength 1583.27

  • 1583.69

Wavelength 1583.69

  • 1584.11

Wavelength 1584.11

  • 1584.53

Wavelength 1584.53

  • 1584.95

Wavelength 1584.95

  • 1585.36

Wavelength 1585.36

  • 1585.78

Wavelength 1585.78

  • 1586.20

Wavelength 1586.20

  • 1586.62

Wavelength 1586.62

  • 1587.04

Wavelength 1587.04

  • 1587.46

Wavelength 1587.46

  • 1587.88

Wavelength 1587.88

  • 1588.30

Wavelength 1588.30

  • 1588.73

Wavelength 1588.73

  • 1589.15

Wavelength 1589.15

  • 1589.57

Wavelength 1589.57

  • 1589.99

Wavelength 1589.99

  • 1590

Wavelength 1590

  • 1590.41

Wavelength 1590.41

  • 1590.83

Wavelength 1590.83

  • 1591.26

Wavelength 1591.26

  • 1591.68

Wavelength 1591.68

  • 1592.10

Wavelength 1592.10

  • 1592.52

Wavelength 1592.52

  • 1592.95

Wavelength 1592.95

  • 1593.37

Wavelength 1593.37

  • 1593.79

Wavelength 1593.79

  • 1594.22

Wavelength 1594.22

  • 1594.64

Wavelength 1594.64

  • 1595.06

Wavelength 1595.06

  • 1595.49

Wavelength 1595.49

  • 1596.34

Wavelength 1596.34

  • 1596.76

Wavelength 1596.76

  • 1597.19

Wavelength 1597.19

  • 1597.62

Wavelength 1597.62

  • 1598.04

Wavelength 1598.04

  • 1598.47

Wavelength 1598.47

  • 1598.89

Wavelength 1598.89

  • 1599.32

Wavelength 1599.32

  • 1599.75

Wavelength 1599.75

  • 1600.06

Wavelength 1600.06

  • 1601.03

Wavelength 1601.03

  • 1601.46

Wavelength 1601.46

  • 1601.88

Wavelength 1601.88

  • 1602.31

Wavelength 1602.31

  • 1602.74

Wavelength 1602.74

  • 1603.17

Wavelength 1603.17

  • 1603.60

Wavelength 1603.60

  • 1604.03

Wavelength 1604.03

  • 1610

Wavelength 1610

  • USE-TWL1

Use Tunable Wavelength 1

<LOSSB>

(Optional) The parameter type is REACH, which indicates the reach values.

  • 100GBASE-LR4

100GBASE-LR4

  • 100GBASE-SR10

100GBASE-SR10

  • 40GBASE-FR

40GBASE-FR

  • 40GBASE-LR4

40GBASE-LR4

  • 40GBASE-SR4

Reach supported on 40GIGE payload on CFP-LC card.

  • 4I1-9D1F

4I1-9D1F

  • C4S1-2D1

C4S1-2D1

  • FE-BX

FE-BX

  • FX

FX

  • GE-BX

GE-BX

  • GE-EX

GE-EX

  • LX-10

LX-10

  • TEN-GE-LRM

TEN-GE-LRM

  • TEN-GE-ZR

TEN-GE-ZR

  • VSR2000-3R2

VSR2000-3R2

  • AUTOPROV

Autoprovisioning

  • CWDM

Coarse wavelength division multiplexing (CWDM)

  • CWDM-40KM

CWDM 40 kilometers.

  • CX

Reach CX

  • CX1

Reach CX1

  • DX

Reach DX

  • HX

Reach HX

  • I1

Reach I1

  • IR-1

Reach IR-1

  • IR-2

Reach IR-2

  • L1

Reach L1

  • L2

Reach L2

  • L3

Reach L3

  • LR-1

Reach LR-1

  • LR-2

Reach LR-2

  • LR-3

Reach LR-3

  • LX

Reach LX

  • P1I1-2D1

Long haul 10G Ethernet with 1310 nm wavelength

  • P1L1-1D2

Longhaul 2.5G Ethernet with 1550 nm wavelength

  • P1L1-2D2

Long haul 10G Ethernet with 1550 nm wavelength

  • P1S1-1D1

Shorthaul 2.5G Ethernet with 1310 nm wavelength

  • P1S1-2D1

Short haul 10G Ethernet in 1310 nm wavelength

  • SC

Reach SC

  • S1

Reach S1

  • S2

Reach S2

  • SR

Reach SR

  • SR-1

Reach SR-1

  • SX

Reach SX

  • T

Reach T

  • TEN-GE-ER

10 GE extended range

  • TEN-GE-LR

10 GE long range

  • TEN-GE-SR

10 GE short range

  • ULH

Reach ULH

  • VSR

Reach VSR

  • VX

Reach VX

  • ZX

Reach ZX

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer. Defaults to 32.

<LIENABLE>

(Optional) Enable or Disable link integrity timer. Takes either Y or N. Value Y enables the LITIMER and value N disables LITIMER.

By default LITIMER is enabled.

Note The LIENABLE parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<LITIMER>

(Optional) Link integrity timer duration in the range between 200 ms and 10000 ms in multiples on 100 ms.

Note The LITIMER parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

  • <OSC>

To enable or disable the OSC on the port.

Note The OSC parameter is supported only on 15454-M2 and 15454-M6.

<ENCAP>

(Optional) Frame encapsulation type. The parameter type is ENCAP, which is the frame encapsulation type.

  • GFP

GFP frame mode

  • HDLC

HDLC frame mode

  • WIS

WIS mode

  • CBR

CBR mapping mode.

  • TRP

Transparent mapping mode.

  • GMP

GMP mapping mode. Supported only on 8GFC on 10x10G-LC card.

<PAUSEFRAME>

To Enable or Disable the Pause Frame.

  • Y

Enable

  • N

Disable

<CLNTDST>

Client distance in kilometers.

  • 10KM

10 kilometers.

  • 30KM

30 kilometers.

<EXPDUPLEX>

(Optional) Ethernet duplex mode. The parameter type is ETHER_DUPLEX, which is the duplex mode.

  • AUTO

Auto mode

  • FULL

Full mode

  • HALF

Half mode

<SELECTIVEAUTO>

(Optional) Selective auto-negotiation. The parameter is Y or N (enable or disable auto-negotiation) This indicates selective auto-negotiation of EXPSPEED and EXPDUPLEX only.

  • Y

Enable selective auto-negotiation.

  • N

Disable selective auto-negotiation.

<EXPSPEED>

(Optional) Ethernet speed. The parameter type is ETHER_SPEED, which is the Ethernet speed.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 10_MBPS

10 Megabits per second

  • 1_GBPS

1 Gigabit per second

  • 40_GBPS

40 Gigabit per second

  • AUTO

Auto

  • AUTO_FDX

Enable auto negotiation with full duplex.

<SYNCMSG>

Indicates if the BITS facility supports synchronization status message. Default is ON (Y). The parameter type is EXT_RING, which indicates whether the ring supports the extended K1/K2/K3 protocol.

  • N

The ring does not support the extended K1/K2/K3 protocol.

  • Y

The ring does support the extended K1/K2/K3 protocol.

<SENDDUS>

The facility will send the DUS (Do not use for Synchronization) value as the SSM for that facility. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<ADMSSM>

SSM selectable value. It will only appear when SSM is disabled. Defaults to STU. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SONET.

  • DUS

Do Not Use For Synchronization

  • PRS

Primary Reference Source, Stratum 1 Traceable

  • RES

Reserved For Network Synchronization Use

  • SMC

SONET Minimum Clock Traceable

  • ST2

Stratum 2 Traceable

  • ST3

Stratum 3 Traceable

  • ST3E

Stratum 3E Traceable

  • ST4

Stratum 4 Traceable

  • STU

Synchronized, Traceability Unknown

  • TNC

Transit Node Clock (2nd Generation Only)

<ESMC>

By enabling ESMC, Gige port can be enabled as timing reference

  • N

Disable

  • Y

Enable

<PAUSEFRAME>

To Enable or Disable the Pause Frame.

  • N

Disable

  • Y

Enable

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • MT

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.3 ED-<MOD1FCPAYLOAD>

(Cisco ONS 15454 SDH) The Edit 1GISC3, 2GISC3, D1VIDEO, DV6000, ESCON, ETRCLO, HDTV or PASSTHRU (ED-<MOD1FCPAYLOAD>) command edits the attributes related with the Fibre Channel facility. The state Locked,AutomaticInService is not supported on the FC port. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

The user can change the service state of a facility to locked-enabled or disabled, only if all the following conditions are met

  • The facility is not sourcing a synchronization clock
  • The facility's DCC is disabled.
  • The facility is not part of a protection group
  • The facility is not supporting cross-connects

Note The conditions stipulated can be overridden by using the CMDMDE=FRCD option. The FRCD option will immediately remove the facility from service with no consideration for orderly interruption. Do not use in scripts or automated batch operations.



Note To completely disable the CMDMDE=FRCD option, provision the <to be defined parameter> in the NE defaults to FALSE. This will prevent the FRCD option from being honored by the NE. The NE default parameter can be provisioned using the CTC only.



Note • The port parameters VIZ, LINKRCVRY, DISTEXTN, AUTODETECTION, LINKCREDITS, and MFS can be edited only if the port state is OOS, Maintenance or OOS,DSBLD.

  • The port parameters AUTODETECTION, LINKCREDITS, and MFS can be edited only if distance extension is enabled (set to B2B).
  • When 1GFICON and 2GFICON payloads are provisioned, distance extension=B2B is the default and only valid setting. Setting distance extension (using the ED-nGFICON command) to any other setting will be denied with an error message, for example, Provisioning Rules Failed.


 

Category

Ports

Security

Provisioning

Input Format

ED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],[DISTEXTN= <DISTANCE_EXTENSION>],[AUTODETECTION=<AUTO_DETECTION>], [LINKCREDITS=<CREDITS>],[FASTSWITCH=<FASTSWITCH>],[MFS=<MAXFRMSIZE>] ,[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>],[SQUELCH=<SQUELCH>],[ENCAP=<ENCAP>][:<PST>[,<SST>]];

Input Example

ED-1GFC:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,FASTSWITCH=,MFS=2148,NAME="FC PORT",CMDMDE=NORM,SOAK=32,
FREQ=1550,LOSSB=LR-1:LOCKED,MAINTENANCE;

Table 11-2 ED-<MOD1FCPAYLOAD> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<LINKRCVRY>

(Optional) Link recovery. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<DISTEXTN>

(Optional) Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None. The parameter type is DISTANCE_EXTENSION (distance extension).

Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time.

  • B2B

Buffer to buffer flow control

  • NONE

No distance extension

<AUTODETECTION>

(Optional) Autodetection. Turns autodetection on or off. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<LINKCREDITS>

(Optional) Number of link credits. If autodetection is set to off, the value of the link credits will be used to configure the hardware. LINKCREDITS is an integer.

<MFS>

(Optional) Maximum frame size. MFS is an integer.

<NAME>

(Optional) NAME is a string. User-assigned port name.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<FREQ>

(Optional) Parameter type is OPTICAL_WLEN (optical wavelength).

  • 1310

Wavelength 1310

  • 1470

Wavelength 1470

  • 1490

Wavelength 1490

  • 1510

Wavelength 1510

  • 1528.77

Wavelength 1528.77

  • 1529.55

Wavelength 1529.55

  • 1529.94

Wavelength 1529.94

  • 1530

Wavelength 1530

  • 1530.33

Wavelength 1530.33

  • 1530.73

Wavelength 1530.73

  • 1531.12

Wavelength 1531.12

  • 1531.51

Wavelength 1531.51

  • 1531.90

Wavelength 1531.90

  • 1532.29

Wavelength 1532.29

  • 1532.68

Wavelength 1532.68

  • 1533.07

Wavelength 1533.07

  • 1533.47

Wavelength 1533.47

  • 1533.86

Wavelength 1533.86

  • 1534.25

Wavelength 1534.25

  • 1534.64

Wavelength 1534.64

  • 1535.04

Wavelength 1535.04

  • 1535.43

Wavelength 1535.43

  • 1535.82

Wavelength 1535.82

  • 1536.22

Wavelength 1536.22

  • 1536.61

Wavelength 1536.61

  • 1537

Wavelength 1537

  • 1537.40

Wavelength 1537.40

  • 1537.79

Wavelength 1537.79

  • 1538.19

Wavelength 1538.19

  • 1538.58

Wavelength 1538.58

  • 1538.98

Wavelength 1538.98

  • 1539.37

Wavelength 1539.37

  • 1539.77

Wavelength 1539.77

  • 1540.16

Wavelength 1540.16

  • 1540.56

Wavelength 1540.56

  • 1540.95

Wavelength 1540.95

  • 1541.35

Wavelength 1541.35

  • 1541.75

Wavelength 1541.75

  • 1542.14

Wavelength 1542.14

  • 1542.35

Wavelength 1542.35

  • 1542.54

Wavelength 1542.54

  • 1542.94

Wavelength 1542.94

  • 1543.33

Wavelength 1543.33

  • 1543.73

Wavelength 1543.73

  • 1544.13

Wavelength 1544.13

  • 1544.53

Wavelength 1544.53

  • 1544.92

Wavelength 1544.92

  • 1545.32

Wavelength 1545.32

  • 1545.72

Wavelength 1545.72

  • 1546.12

Wavelength 1546.12

  • 1546.52

Wavelength 1546.52

  • 1546.92

Wavelength 1546.92

  • 1547.32

Wavelength 1547.32

  • 1547.72

Wavelength 1547.72

  • 1548.12

Wavelength 1548.12

  • 1548.51

Wavelength 1548.51

  • 1548.92

Wavelength 1548.92

  • 1549.32

Wavelength 1549.32

  • 1549.71

Wavelength 1549.71

  • 1550

Wavelength 1500

  • 1550.12

Wavelength 1550.12

  • 1550.52

Wavelength 1550.52

  • 1550.92

Wavelength 1550.92

  • 1551.32

Wavelength 1551.32

  • 1551.72

Wavelength 1551.72

  • 1552.12

Wavelength 1552.12

  • 1552.52

Wavelength 1552.52

  • 1552.93

Wavelength 1552.93

  • 1553.33

Wavelength 1553.33

  • 1553.73

Wavelength 1553.73

  • 1554.13

Wavelength 1554.13

  • 1554.13

Wavelength 1554.13

  • 1554.94

Wavelength 1554.94

  • 1555.34

Wavelength 1555.34

  • 1555.75

Wavelength 1555.75

  • 1556.15

Wavelength 1556.15

  • 1556.55

Wavelength 1556.55

  • 1556.96

Wavelength 1556.96

  • 1557.36

Wavelength 1557.36

  • 1557.77

Wavelength 1557.77

  • 1558.17

Wavelength 1558.17

  • 1558.58

Wavelength 1558.58

  • 1558.98

Wavelength 1558.98

  • 1559.39

Wavelength 1559.39

  • 1559.79

Wavelength 1559.79

  • 1560.20

Wavelength 1560.20

  • 1560.61

Wavelength 1560.61

  • 1561.01

Wavelength 1561.01

  • 1561.42

Wavelength 1561.42

  • 1561.83

Wavelength 1561.83

  • 1570

Wavelength 1570

  • 1570.83

Wavelength 1570.83

  • 1571.24

Wavelength 1571.24

  • 1571.65

Wavelength 1571.65

  • 1572.06

Wavelength 1572.06

  • 1572.48

Wavelength 1572.48

  • 1572.89

Wavelength 1572.89

  • 1573.30

Wavelength 1573.30

  • 1573.71

Wavelength 1573.71

  • 1574.13

Wavelength 1574.13

  • 1574.54

Wavelength 1574.54

  • 1574.95

Wavelength 1574.95

  • 1575.37

Wavelength 1575.37

  • 1575.78

Wavelength 1575.78

  • 1576.20

Wavelength 1576.20

  • 1576.61

Wavelength 1576.61

  • 1577.03

Wavelength 1577.03

  • 1577.44

Wavelength 1577.44

  • 1577.86

Wavelength 1577.86

  • 1578.27

Wavelength 1578.27

  • 1578.69

Wavelength 1578.69

  • 1579.10

Wavelength 1579.10

  • 1579.52

Wavelength 1579.52

  • 1579.93

Wavelength 1579.93

  • 1580.35

Wavelength 1580.35

  • 1580.77

Wavelength 1580.77

  • 1581.18

Wavelength 1581.18

  • 1581.60

Wavelength 1581.60

  • 1582.02

Wavelength 1582.02

  • 1582.44

Wavelength 1582.44

  • 1582.85

Wavelength 1582.85

  • 1583.27

Wavelength 1583.27

  • 1583.69

Wavelength 1583.69

  • 1584.11

Wavelength 1584.11

  • 1584.53

Wavelength 1584.53

  • 1584.95

Wavelength 1584.95

  • 1585.36

Wavelength 1585.36

  • 1585.78

Wavelength 1585.78

  • 1586.20

Wavelength 1586.20

  • 1586.62

Wavelength 1586.62

  • 1587.04

Wavelength 1587.04

  • 1587.46

Wavelength 1587.46

  • 1587.88

Wavelength 1587.88

  • 1588.30

Wavelength 1588.30

  • 1588.73

Wavelength 1588.73

  • 1589.15

Wavelength 1589.15

  • 1589.57

Wavelength 1589.57

  • 1589.99

Wavelength 1589.99

  • 1590

Wavelength 1590

  • 1590.41

Wavelength 1590.41

  • 1590.83

Wavelength 1590.83

  • 1591.26

Wavelength 1591.26

  • 1591.68

Wavelength 1591.68

  • 1592.10

Wavelength 1592.10

  • 1592.52

Wavelength 1592.52

  • 1592.95

Wavelength 1592.95

  • 1593.37

Wavelength 1593.37

  • 1593.79

Wavelength 1593.79

  • 1594.22

Wavelength 1594.22

  • 1594.64

Wavelength 1594.64

  • 1595.06

Wavelength 1595.06

  • 1595.49

Wavelength 1595.49

  • 1596.34

Wavelength 1596.34

  • 1596.76

Wavelength 1596.76

  • 1597.19

Wavelength 1597.19

  • 1597.62

Wavelength 1597.62

  • 1598.04

Wavelength 1598.04

  • 1598.47

Wavelength 1598.47

  • 1598.89

Wavelength 1598.89

  • 1599.32

Wavelength 1599.32

  • 1599.75

Wavelength 1599.75

  • 1600.06

Wavelength 1600.06

  • 1601.03

Wavelength 1601.03

  • 1601.46

Wavelength 1601.46

  • 1601.88

Wavelength 1601.88

  • 1602.31

Wavelength 1602.31

  • 1602.74

Wavelength 1602.74

  • 1603.17

Wavelength 1603.17

  • 1603.60

Wavelength 1603.60

  • 1604.03

Wavelength 1604.03

  • 1610

Wavelength 1610

  • USE-TWL1

Use Tunable Wavelength 1

<LOSSB>

(Optional) Parameter type is REACH (reach values).

  • 100GBASE-LR4

100GBASE-LR4

  • 100GBASE-SR10

100GBASE-SR10

  • 40GBASE-FR

40GBASE-FR

  • 40GBASE-LR4

40GBASE-LR4

  • 40GBASE-SR4

Reach supported on 40GIGE payload on CFP-LC card.

  • 4I1-9D1F

4I1-9D1F

  • C4S1-2D1

C4S1-2D1

  • FE-BX

FE-BX

  • FX

FX

  • GE-BX

GE-BX

  • GE-EX

GE-EX

  • LX-10

LX-10

  • TEN-GE-LRM

TEN-GE-LRM

  • TEN-GE-ZR

TEN-GE-ZR

  • VSR2000-3R2

VSR2000-3R2

  • AUTOPROV

Autoprovisioning

  • CX

Reach CX

  • CX1

Reach CX1

  • DX

Reach DX

  • HX

Reach HX

  • I1

Reach I1

  • IR-1

Reach IR-1

  • IR-2

Reach IR-2

  • L1

Reach L1

  • L2

Reach L2

  • L3

Reach L3

  • LR-1

Reach LR-1

  • LR-2

Reach LR-2

  • LR-3

Reach LR-3

  • LX

Reach LX

  • S1

Reach S1

  • S2

Reach S2

  • SR

Reach SR

  • SR-1

Reach SR-1

  • SX

Reach SX

  • T

Reach T

  • TEN-GE-ER

10 GE extended range

  • TEN-GE-LR

10 GE long range

  • TEN-GE-SR

10 GE short range

  • VX

Reach VX

  • ZX

Reach ZX

<ENCAP>

Specifies the mapping mode on the port provisioned. Parameter Type is ENCAP.

  • CBR

CBR mapping mode.

  • GFP

GFP mapping mode.

  • GMP

GMP mapping mode is supported only on 8GFC on 10x10G-LC card.

  • TRP

Transparent mapping mode.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. the parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.4 ED-<MOD1FICONPAYLOAD>

(Cisco ONS 15454 SDH) The Edit 1GFICON, 2GFICON, 4GFICON, or ESCON (ED-<MOD1FICONPAYLOAD>) command edits the attributes related with the FICON payload facility. The state Locked,AutomaticInService is not supported on the FICON port. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ports

Security

Provisioning

Input Format

ED-<MOD1FICONPAYLOAD>[:<TID>]:<AID>:<CTAG>[:::LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTANCE_EXTENSION>],[AUTODETECTION=<AUTO_DETECTION>],[LINKCREDITS=<CREDITS>],[FASTSWITCH=<FASTSWITCH>],[MFS=<MAXFRMSIZE>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[SQUELCH=<SQUELCH>],[SQUELCHMODE=<SQUELCHMODE>],[ENCAP=<ENCAP>][:<PST>[,<SST>]];

Input Example

ED-1GFICON:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,FASTSWITCH=,MFS=2148,NAME="FC PORT",CMDMDE=NORM,SOAK=32,
FREQ=1550,LOSSB=LR-1::LOCKED,MAINTENANCE;

Table 11-3 ED-<MOD1FICONPAYLOAD> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<LINKRCVRY>

(Optional) Link recovery. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<DISTEXTN>

(Optional) Distance extension. It can be set to B2B Credit Management state or None. The parameter type is DISTANCE_EXTENSION.

Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time.

  • B2B

Buffer to buffer flow control

  • NONE

No distance extension

<AUTODETECTION>

(Optional) Autodetection. Turns autodetection on or off. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<LINKCREDITS>

(Optional) Number of link credits. If autodetection is set to off, the value of the link credits will be used to configure the hardware. LINKCREDITS is an integer.

<FASTSWITCH>

<TBD>

<MFS>

Maximum frame size. MFS is an integer.

<NAME>

NAME is a string. User-assigned port name.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<FREQ>

(Optional) Parameter type is OPTICAL_WLEN, which is the optical wavelength.

  • 1310

Wavelength 1310

  • 1470

Wavelength 1470

  • 1490

Wavelength 1490

  • 1510

Wavelength 1510

  • 1529.55

Wavelength 1529.55

  • 1529.94

Wavelength 1529.94

  • 1530

Wavelength 1530

  • 1530.33

Wavelength 1530.33

  • 1530.73

Wavelength 1530.73

  • 1531.12

Wavelength 1531.12

  • 1531.51

Wavelength 1531.51

  • 1531.90

Wavelength 1531.90

  • 1532.29

Wavelength 1532.29

  • 1532.68

Wavelength 1532.68

  • 1533.07

Wavelength 1533.07

  • 1533.47

Wavelength 1533.47

  • 1533.86

Wavelength 1533.86

  • 1534.25

Wavelength 1534.25

  • 1534.64

Wavelength 1534.64

  • 1535.04

Wavelength 1535.04

  • 1535.43

Wavelength 1535.43

  • 1535.82

Wavelength 1535.82

  • 1536.22

Wavelength 1536.22

  • 1536.61

Wavelength 1536.61

  • 1537

Wavelength 1537

  • 1537.40

Wavelength 1537.40

  • 1537.79

Wavelength 1537.79

  • 1538.19

Wavelength 1538.19

  • 1538.58

Wavelength 1538.58

  • 1538.98

Wavelength 1538.98

  • 1539.37

Wavelength 1539.37

  • 1539.77

Wavelength 1539.77

  • 1540.16

Wavelength 1540.16

  • 1540.56

Wavelength 1540.56

  • 1540.95

Wavelength 1540.95

  • 1541.35

Wavelength 1541.35

  • 1541.75

Wavelength 1541.75

  • 1542.14

Wavelength 1542.14

  • 1542.35

Wavelength 1542.35

  • 1542.54

Wavelength 1542.54

  • 1542.94

Wavelength 1542.94

  • 1543.33

Wavelength 1543.33

  • 1543.73

Wavelength 1543.73

  • 1544.13

Wavelength 1544.13

  • 1544.53

Wavelength 1544.53

  • 1544.92

Wavelength 1544.92

  • 1545.32

Wavelength 1545.32

  • 1545.72

Wavelength 1545.72

  • 1546.12

Wavelength 1546.12

  • 1546.52

Wavelength 1546.52

  • 1546.92

Wavelength 1546.92

  • 1547.32

Wavelength 1547.32

  • 1547.72

Wavelength 1547.72

  • 1548.12

Wavelength 1548.12

  • 1548.51

Wavelength 1548.51

  • 1548.92

Wavelength 1548.92

  • 1549.32

Wavelength 1549.32

  • 1549.71

Wavelength 1549.71

  • 1550

Wavelength 1500

  • 1550.12

Wavelength 1550.12

  • 1550.52

Wavelength 1550.52

  • 1550.92

Wavelength 1550.92

  • 1551.32

Wavelength 1551.32

  • 1551.72

Wavelength 1551.72

  • 1552.12

Wavelength 1552.12

  • 1552.52

Wavelength 1552.52

  • 1552.93

Wavelength 1552.93

  • 1553.33

Wavelength 1553.33

  • 1553.73

Wavelength 1553.73

  • 1554.13

Wavelength 1554.13

  • 1554.13

Wavelength 1554.13

  • 1554.94

Wavelength 1554.94

  • 1555.34

Wavelength 1555.34

  • 1555.75

Wavelength 1555.75

  • 1556.15

Wavelength 1556.15

  • 1556.55

Wavelength 1556.55

  • 1556.96

Wavelength 1556.96

  • 1557.36

Wavelength 1557.36

  • 1557.77

Wavelength 1557.77

  • 1558.17

Wavelength 1558.17

  • 1558.58

Wavelength 1558.58

  • 1558.98

Wavelength 1558.98

  • 1559.39

Wavelength 1559.39

  • 1559.79

Wavelength 1559.79

  • 1560.20

Wavelength 1560.20

  • 1560.61

Wavelength 1560.61

  • 1561.01

Wavelength 1561.01

  • 1561.42

Wavelength 1561.42

  • 1561.83

Wavelength 1561.83

  • 1570

Wavelength 1570

  • 1570.83

Wavelength 1570.83

  • 1571.24

Wavelength 1571.24

  • 1571.65

Wavelength 1571.65

  • 1572.06

Wavelength 1572.06

  • 1572.48

Wavelength 1572.48

  • 1572.89

Wavelength 1572.89

  • 1573.30

Wavelength 1573.30

  • 1573.71

Wavelength 1573.71

  • 1574.13

Wavelength 1574.13

  • 1574.54

Wavelength 1574.54

  • 1574.95

Wavelength 1574.95

  • 1575.37

Wavelength 1575.37

  • 1575.78

Wavelength 1575.78

  • 1576.20

Wavelength 1576.20

  • 1576.61

Wavelength 1576.61

  • 1577.03

Wavelength 1577.03

  • 1577.44

Wavelength 1577.44

  • 1577.86

Wavelength 1577.86

  • 1578.27

Wavelength 1578.27

  • 1578.69

Wavelength 1578.69

  • 1579.10

Wavelength 1579.10

  • 1579.52

Wavelength 1579.52

  • 1579.93

Wavelength 1579.93

  • 1580.35

Wavelength 1580.35

  • 1580.77

Wavelength 1580.77

  • 1581.18

Wavelength 1581.18

  • 1581.60

Wavelength 1581.60

  • 1582.02

Wavelength 1582.02

  • 1582.44

Wavelength 1582.44

  • 1582.85

Wavelength 1582.85

  • 1583.27

Wavelength 1583.27

  • 1583.69

Wavelength 1583.69

  • 1584.11

Wavelength 1584.11

  • 1584.53

Wavelength 1584.53

  • 1584.95

Wavelength 1584.95

  • 1585.36

Wavelength 1585.36

  • 1585.78

Wavelength 1585.78

  • 1586.20

Wavelength 1586.20

  • 1586.62

Wavelength 1586.62

  • 1587.04

Wavelength 1587.04

  • 1587.46

Wavelength 1587.46

  • 1587.88

Wavelength 1587.88

  • 1588.30

Wavelength 1588.30

  • 1588.73

Wavelength 1588.73

  • 1589.15

Wavelength 1589.15

  • 1589.57

Wavelength 1589.57

  • 1589.99

Wavelength 1589.99

  • 1590

Wavelength 1590

  • 1590.41

Wavelength 1590.41

  • 1590.83

Wavelength 1590.83

  • 1591.26

Wavelength 1591.26

  • 1591.68

Wavelength 1591.68

  • 1592.10

Wavelength 1592.10

  • 1592.52

Wavelength 1592.52

  • 1592.95

Wavelength 1592.95

  • 1593.37

Wavelength 1593.37

  • 1593.79

Wavelength 1593.79

  • 1594.22

Wavelength 1594.22

  • 1594.64

Wavelength 1594.64

  • 1595.06

Wavelength 1595.06

  • 1595.49

Wavelength 1595.49

  • 1596.34

Wavelength 1596.34

  • 1596.76

Wavelength 1596.76

  • 1597.19

Wavelength 1597.19

  • 1597.62

Wavelength 1597.62

  • 1598.04

Wavelength 1598.04

  • 1598.47

Wavelength 1598.47

  • 1598.89

Wavelength 1598.89

  • 1599.32

Wavelength 1599.32

  • 1599.75

Wavelength 1599.75

  • 1600.06

Wavelength 1600.06

  • 1601.03

Wavelength 1601.03

  • 1601.46

Wavelength 1601.46

  • 1601.88

Wavelength 1601.88

  • 1602.31

Wavelength 1602.31

  • 1602.74

Wavelength 1602.74

  • 1603.17

Wavelength 1603.17

  • 1603.60

Wavelength 1603.60

  • 1604.03

Wavelength 1604.03

  • 1610

Wavelength 1610

  • USE-TWL1

Use Tunable Wavelength 1

<LOSSB>

The parameter type is REACH, which is the reach value.

  • 100GBASE-LR4

100GBASE-LR4

  • 100GBASE-SR10

100GBASE-SR10

  • 40GBASE-FR

40GBASE-FR

  • 40GBASE-LR4

40GBASE-LR4

  • 40GBASE-SR4

Reach supported on 40GIGE payload on CFP-LC card.

  • 4I1-9D1F

4I1-9D1F

  • C4S1-2D1

C4S1-2D1

  • FE-BX

FE-BX

  • FX

FX

  • GE-BX

GE-BX

  • GE-EX

GE-EX

  • LX-10

LX-10

  • TEN-GE-LRM

TEN-GE-LRM

  • TEN-GE-ZR

TEN-GE-ZR

  • VSR2000-3R2

VSR2000-3R2

  • AUTOPROV

Autoprovisioning

  • CX

Reach CX

  • CX1

Reach CX1

  • DX

Reach DX

  • HX

Reach HX

  • I1

Reach I1

  • IR-1

Reach IR-1

  • IR-2

Reach IR-2

  • L1

Reach L1

  • L2

Reach L2

  • L3

Reach L3

  • LR-1

Reach LR-1

  • LR-2

Reach LR-2

  • LR-3

Reach LR-3

  • LX

Reach LX

  • S1

Reach S1

  • S2

Reach S2

  • SR

Reach SR

  • SR-1

Reach SR-1

  • SX

Reach SX

  • T

Reach T

  • TEN-GE-ER

10 GE extended range

  • TEN-GE-LR

10 GE long range

  • TEN-GE-SR

10 GE short range

  • VX

Reach VX

  • ZX

Reach ZX

<ENCAP>

Specifies the mapping mode on the port provisioned. Parameter Type is ENCAP.

  • CBR

CBR mapping mode.

  • GFP

GFP mapping mode.

  • GMP

GMP mapping mode is supported only on 8GFC on 10x10G-LC card.

  • TRP

Transparent mapping mode.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. the parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.5 ED-<MOD2DWDMPAYLOAD>

(Cisco ONS 15454 SDH, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Edit 10GFC, 10GIGE, 100GIGE, 40GIGE, 1GFC, 1GFICON, 1GISC3, 2GFC, 2GFICON, 2GISC3, 4GFC, 4GFICON, 5GIB, 8GFC, D1VIDEO, DV6000, DVBASI, ESCON, ETRCLO, GIGE, HDTV, ISC1, ISC3, OTU3, OTU4, PASSTHRU, AUTO, 3GVIDEO, SDSDI , HDSDI, OTU1, OTU2, ISC3STP1G, or ISC3STP2G (ED-<MOD2DWDMPAYLOAD>) command edits the operating parameters for a DWDM client facility. See Table 27-1 for supported modifiers by platform. This command creates GCC with a given GCCRATE.

 
Usage Guidelines

The command supports the modifier AUTO, 3GVIDEO, SDSDI, HDSDI, OTU1, ISC3STP1G, and ISC3STP2G.

  • Squelchmode applicable for SDSDI, HDSDI, 3GVIDEO, ISC3STG1G, ISC3STP2G, and ESCON are NONE and SQUELCH.
  • Squelchmode applicable for 1GFC, 2GFC, 4GFC in NON-TXP mode and 8GFC are NONE, NOS and SQUELCH.
  • Squelchmode for 4GFC client in TXP modes are NONE and NOS.
  • The only allowed Squelchmode for 4GFC trunk is SQUELCH
  • Video RATES - NTSC/PAL can be set based on ANSI/ETSI chassis types respectively for HDSDI and 3GVIDEO.
  • Video RATE is not applicable for other video payloads - SDSDI, ESCON, ISC3STP1G, and ISC3STP2G.
  • Video RATE is also not applicable for 1G/2G/3G/4G/8G-FC payloads.
  • Editing the working port will automatically edit the protect port.
  • OVRCLK is the new parameter added and applicable for OTU2 payload on SFP+ ports of 10x10G-LC only.

Category

DWDM

Security

Provisioning

Input Format

ED-<MOD2DWDMPAYLOAD>[:<TID>]:<AID>:<CTAG>[:::LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTANCE_EXTENSION>],[AUTODETECTION=<AUTO_DETECTION>],[LINKCREDITS=<CREDITS>],[FASTSWITCH=<FASTSWITCH>],[MFS=<MAXFRMSIZE>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[SQUELCH=<SQUELCH>],[SQUELCHMODE=<SQUELCHMODE>],[ENCAP=<ENCAP>],[:<PST>[,<SST>]];

Input Example

ED-SDSDI::VFAC-3-1-1:1:::SQUELCHMODE=SQUELCH;

Table 11-4 ED-<MOD2DWDMPAYLOAD> Command - Parameter Support

Input Parameters
Description

<AID>

The AR-MXP, AR-XP, and AR-XPE cards use the VFAC Access Identifier. See access identifier from the “ALL” section.

<SQUELCHMODE>

Shuts down the far-end laser in response to certain defects.

  • DISABLE

Disable

  • AIS

AIS

  • G-AIS

Generis AIS

  • ODU-AIS

ODU AIS

  • SQUELCH

Squelch is enabled

  • NONE

Transparent

  • NOS

Disable in FC payloads.

<ENCAP>

Specifies the mapping mode on the port provisioned. Parameter Type is ENCAP.

  • CBR

CBR mapping mode.

  • GFP

GFP mapping mode.

  • GMP

GMP mapping mode is supported only on 8GFC on 10x10G-LC card.

  • TRP

Transparent mapping mode.

11.6 ED-<MOD_PATH>

(Cisco ONS 15454 SDH) The Edit VC3, VC44C, VC464C, VC48C, VC4, VC416C, VC42C, VC43C, VC11, or VC12 (ED-<MOD_PATH>) command edits the attributes associated with VC paths.

 
Usage Guidelines

The SFBER, SDBER, RVRTV, and RVTM parameters only apply to subnetwork connection protection (SNCP) at the VC path level.

The path trace message is a 64-character string including the terminating carriage return (CR) and line feed (LF) that is transported in the J1 byte of the SDH VC Path overhead.

Both the EXPTRC and TRC string can be provisioned by a user with up to a 62-character string.The EXPTRC parameter indicates that the contents of the expected incoming path trace are provisioned by the user. The TRC parameter indicates the contents of the outgoing path trace message.

The INCTRC parameter indicates the contents of the incoming path trace message.

Path trace has three modes: OFF, MANUAL, and AUTO. The path trace mode defaults to OFF. The MANUAL mode performs the comparison of the received string with the user-entered expected string. The AUTO mode performs the comparison of the present received string with an expected string set to a previously received string. If there is a mismatch, TIM-P alarm is raised. When the path trace mode is in OFF mode, there is no path trace processing, and all the alarm and state conditions are reset.

The TACC parameter edits an existing single VC or VT and changes it to a test access point. When an editing command on TACC is executed, it assigns the VC or VT for the first two-way connection and VC+1 as the second 2-way connection. For single facility access digroup (FAD) test access, only a single VC/VT is used for the TAP creation. For more information on TACC, refer to the Cisco ONS SDH and Cisco ONS 15600 SDH TL1 Reference Guide .

J1 is implemented on the E1, E3, E4, DS3i-N-12, and STM cards.

E100 and E1000 cards do not support path trace.

The STM1, STM16AS, and STM64 cards only support EXPTRC in the ED-VC-PATH command.


NoteEach TL1 command must be less than or equal to 255 characters. Any command larger than 255 characters must be split into multiple commands. For example, if you use the ED-<VC_PATH> command to edit the J1 EXPTRC/TRC message, SNCP attributes, and TACC attributes and the command exceeds 255 characters, the command will not be processed. You must use multiple ED-<VC_PATH> commands instead.


The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

The following actions will return error messages:

  • Sending this command to edit SFBER, SDBER, RVRTV or RVTM for the non-SNCP VC path.
  • Sending this command to edit the EXPTRC string with the AUTO path trace mode (TRCMODE=AUTO).
  • Sending this command to edit both TACC and any other attribute(s) will return the “Parameters Not Compatible” error message.
  • Sending this command to edit TACC on an AID with cross-connects will return the “VC in Use” error message.

This command is allowed to edit EXPTRC on STM1, STM16AS, and STM64 cards.


Note • TACC creation will be denied on protect ports and cards in 1:1, 1:N, and 1+1 configurations.

  • The VFAC AID is only valid on slots containing an ML-Series card. TACC is not supported for the ML-Series cards.
  • After the MS-SPRing switching, provisioning of the J1 trace string or trace mode is not allowed on the protection path.
  • TACC creation is allowed on protection channel access (PCA) for two-fiber and four-fiber MS-SPRing.
  • TACC is not supported on G1000, MXP_2.5_10G, TXP_MR_10G, ML1000-2, and ML100T-12 cards.
  • HOLDOFFTIMER is not specific to a path. It is applicable to the SNCP selector. If HOLDOFFTIMER is changed on one path associated with the selector, the HOLDOFFTIMER of the other path associated with the same selector is also changed.
  • The cross-connects on the DS3i-N-12 card are VC4 width, but the individual VC1s within the 3C will be accessible. For editing the path attributes, use ED-VC3 with the FAC AID. For test access creation, use ED-VC4 because the test access path width (like the cross-connect) has to be 3C on the DS3i-N-12 card, which creates a new entity (TAP) on the DS3i-N-12 card in 3C width. On the DS3i-N-12 card, the ED-VC command can be used either with VC3 or VC4 modifier depending on the parameter to be modified.


 

Category

Paths

Security

Provisioning

Input Format

ED-<MOD_PATH>:[TID]:<AID>:[CTAG]:::[SFBER=<SFBER>],[SDBER=<SDBER>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[HOLDOFFTIMER=<HOLDOFFTIMER>],
[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>],
[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-VC3:FERNDALE:VC3-1-1-1:115:::SFBER=1E-3,SDBER=1E-5,RVRTV=Y,RVTM=1.0,
HOLDOFFTIMER=2000,EXPTRC=“EXPTRCSTRING”,TRC=“TRCSTRING”,
TRCMODE=OFF,TACC=8,TAPTYPE=SINGLE,CMDMDE=NORM:UNLOCKED,
AUTOMATICINSERVICE;

 

Table 11-5 ED-<MOD_PATH> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “CrossConnectId1” section.

<SFBER>

(Optional) Signal failure threshold. Applies only to SNCP. Applies to VC4-level paths. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.

  • 1E-3

SFBER is 1E-3.

  • 1E-4

SFBER is 1E-4.

  • 1E-5

SFBER is 1E-5.

<SDBER>

(Optional) Signal degrade threshold. Applies only to SNCP. Applies to VC4-level paths (VCn). The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.

  • 1E-5

SDBER is 1E-5.

  • 1E-6

SDBER is 1E-6.

  • 1E-7

SDBER is 1E-7.

  • 1E-8

SDBER is 1E-8.

  • 1E-9

SDBER is 1E-9.

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to SNCP. The parameter type is ON_OFF, which disables or enables an attribute.

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. RVTM is not allowed to be set while RVRTV is N. Only applies to SNCP. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

  • N

Disable an attribute.

  • Y

Enable an attribute.

<HOLDOFFTIMER>

(Optional) Hold-off timer for SNCP DRI. Values must be within 0 and 10000 milliseconds (0 to 10 seconds), with increments of 100 milliseconds. HOLDOFFTIMER is an integer.

<EXPTRC>

(Optional) Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR and LF. Applicable to VC-level paths in SDH (VCn). EXPTRC is a string.

<TRC>

(Optional) The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. A null value defaults to the NE transmitting null characters (Hex 00). Applicable to VC-level paths in SDH (VCn). TRC is a string.

<TRCMODE>

(Optional) Path trace mode. Applicable only to VC-level paths in SDH (VCn). Defaults to the OFF mode. The parameter type is TRCMODE (trace mode).

  • AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards.

  • AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on alarm indication signal (AIS) and remote defect indication (RDI) if TIM-P is detected.

  • MAN

Use the provisioned expected string as the expected string.

  • MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected.

  • OFF

Turn off path trace capability. Nothing will be reported.

<TACC>

(Optional) TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. TACC is an integer.

<TAPTYPE>

(Optional) TAP type. the parameter type is TAPTYPE (test access point type).

  • DUAL

Dual FAD

  • SINGLE

Single FAD

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. the parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.7 ED-<MOD_RING>

(Cisco ONS 15454 SDH) The Edit Multiplex Section-Shared Protection Ring (ED-<MOD_RING>) command edits the MS-SPRing attributes.

 
Usage Guidelines

The RVRTV, RVTM, SRVRTV, SRVTM, NODEID, and RINGID attributes can be edited for the four-fiber MS-SPRing.

The RVRTV, RVTM, NODEID, and RINGID attributes can be edited for the two-fiber MS-SPRing.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

The following actions will produce errors:

  • If the system fails on getting IOR, a SROF (Get IOR Failed) error message is returned
  • If the AID is invalid, an IIAC (Invalid AID) error message is returned.
  • If the MS-SPRing does not exist, a SRQN (MSSPR Does Not Exist) error message is returned.
  • The SROF (Facility Not Provisioned) or SROF (Cannot Access MSSPR) error message will be returned for an invalid query.
  • The SRQN (MSSPR Edition Failed) error message is returned for an invalid edition query.
  • Sending this command to modify SRVRTV or SRVTM on a two-fiber MS-SPRing will return an IDNV (Invalid Data For 2F-MS-SPRing) error message.
  • Sending this command to modify the node ID with invalid data will return an IIAC (Invalid NodeId) error message.
  • Sending this command to change the ring ID into invalid data will return an IIAC (Invalid RingId) error message.
  • Changing the MS-SPRing node ID with a duplicated ID will return a SROF (Cannot Set NodeId) error message.
  • Changing the MS-SPRing ring ID with a duplicated ID will return a SROF (Cannot Set RingId) error message.

Note • The ALL AID is invalid for this command.

  • The list AID format is supported in Release 4.6 and later.


 

Category

MS-SPRing

Security

Provisioning

Input Format

ED-<MOD_RING>:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],[SRVTM=<SRVTM>][:];

Input Example

ED-BLSR:PETALUMA:MSSPR-43:123:::RINGID=43,NODEID=3,RVRTV=Y,RVTM=2.0,
SRVRTV=Y,SRVTM=5.0;

 

Table 11-6 ED-<MOD_RING> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “AidUnionId1” section. Identifies the MS-SPRing of the NE. ALL or MSSPR-ALL AID is not allowed for editing an MS-SPRing.

<RINGID>

The MS-SPRing ID of the NE, up to six characters. Valid characters are A-Z and 0-9. RINGID is a string.

<NODEID>

The MS-SPRing node ID of the NE. NODEID ranges from 0 to 31. NODEID is an integer.

<RVRTV>

Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

RVTM

Revertive time. RVTM is not allowed to be set while “RVRTV” is N. the parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<SRVRTV>

The span revertive mode for four-fiber MS-SPRing only. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<SRVTM>

The span revertive time for four-fiber MS-SPRing only. SRVTM is not allowed to be set while SRVRTV is N. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

11.8 ED-<STM_TYPE>

(Cisco ONS 15454 SDH) The Edit STM1, STM4, STM16, or STM64 command edits the attributes (for example, service parameters) and state of an STM facility. Allowable states for a facility are Locked, Locked with Automatic In Service transitioning, Locked for Maintenance, and Unlocked. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

The OPRNOMINAL parameter is supported only by optical card types that support Optical PM. The following cards support OPRNOMINAL: STM1-8, MRC-12, MRC-12-2.5G, MRC-4-2.5G, STM64-XFP, CTX-2500, CTX, STM64-4, STM16-16, STM64-4-DWDM, ASAP-4.

The data communications channel (DCC) transmit is bridged to both working and protect in a 1+1 configuration. On the receive side, the active one is selected for DCC. The DCC is provisioned on the working port only in a 1+1 configuration.

All lines in a 1+1 MS-SPRing must have the same mode. If you change the mode of a line that is in a 1+1 MS-SPRing, an error message will be returned.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

You cannot directly transition a facility from IS to Locked-Disabled,DSBLD service state. You can transition a facility to Locked-Disabled, DSBLD service state from any state except Locked-Disabled, Maintenance. To transition a facility from Locked-Disabled, Maintenance to Locked-Disabled, DSBLD service state, all the following conditions must be met:

  • The facility is not sourcing a synchronization clock
  • The facility's DCC is disabled
  • The facility is not part of a protection group
  • The facility is not supporting cross-connects
  • The facility is not using overhead connections or overhead terminations (such as express orderwire, local orderwire, or user data channels [UDCs])

Note The conditions stipulated can be overridden by using the CMDMDE=FRCD option. The FRCD option will immediately remove the facility from service (except for IS to Locked-Disabled, DSBLD transition) with no consideration for orderly interruption.


Category

Ports

Security

Provisioning

Input Format

ED-<STM_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>],
[SOAK=<SOAK>],[OSPF=<OSPF>],[MSDCC=<MSDCC>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>],
[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>],
[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],
[FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>],OPRNOMINAL=<OPRNOMINAL>]:[<PST>[,<SST>]];

Input Example

ED-STM16:PENNGROVE:FAC-6-1:114:::DCC=Y,AREA=10.92.63.1,SYNCMSG=N,SENDDUS=N,
PJMON=48,SFBER=1E-4,SDBER=1E-6,MODE=SINGLESHELF,MUX=E2,SOAK=10,OSPF=Y,
MSDCC=N,NAME="STMPORT",CMDMDE=NORM,EXPTRC="AAA",TRC="AAA",
TRCMODE=MAN,TRCFORMAT=16-BYTE,ADMSSM=G811,SENDDUSFF=N,
AISONLPBK=AIS_ON_LPBK_ALL,FREQ=1550,LOSSB=LR-1,FOREIGNFEND=N,
FOREIGNIP="IPADDRESS",OPRNOMINAL=Y:UNLOCKED,AUTOMATICINSERVICE;

 

Table 11-7 ED-STM1 Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<DCC>

(Optional) Indicates whether or not the RS-DCC is to be used. Identifies the RS-DCC connection of the port. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<AREA>

(Optional) The area ID shows up only if the DCC is enabled.

<SYNCMSG>

(Optional) Synchronization status message. The parameter type is EXT_RING, which indicates if the ring supports the extended K1/K2/K3 protocol.

  • N

The ring does not support the extended K1/K2/K3 protocol.

  • Y

The ring does support the extended K1/K2/K3 protocol.

<SENDDUS>

(Optional) Whether the facility will send the Do Not Use for Synchronization (DUS) value as the synchronization status message for that facility. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<PJMON>

(Optional) Identifies an STM port PJMON. Defaults to 0 (zero). PJMON is an integer. Set a valid VC4 number of the optical port.

Note The PJMON number displayed in TL1 interface does not correspond to the PJVC4MON number in CTC, but instead corresponds to the VC4 number of the optical port.

<SFBER>

(Optional) Signal failure threshold. the parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.

  • 1E-3

SFBER is 1E-3.

  • 1E-4

SFBER is 1E-4.

  • 1E-5

SFBER is 1E-5.

<SDBER>

(Optional) Signal degrade threshold. the parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.

  • 1E-5

SDBER is 1E-5

  • 1E-6

SDBER is 1E-6

  • 1E-7

SDBER is 1E-7

  • 1E-8

SDBER is 1E-8

  • 1E-9

SDBER is 1E-9

<MODE>

(Optional) STM port mode. The parameter type is OPTICAL_MODE, which is the facility’s optical mode.

  • SINGLESHELF

The NE contains only one shelf and the AID representation does not consider the shelf identifier for command requests/response and autonomous reports.

  • MULTISHELF

The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style.

  • MULTISHELFETH

The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style. The shelves are connected by means of an external Ethernet switch.

<MUX>

(Optional) MS-SPRing extension byte (supported only on the STM16AS card). The parameter type is MUX_TYPE, which is the MS-SPRing extension type.

  • E2

E2 byte (orderwire)

  • F1

F1 byte (user)

  • K3

K3 byte

  • Z2

Z2 byte

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<OSFP>

(Optional) The Open Shortest Path First discovery. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<MSDCC>

(Optional) The MS-DCC connection on the port. The parameter type is EXT_RING, which indicates if the ring supports the extended K1/K2/K3 protocol.

  • N

The ring does not support the extended K1/K2/K3 protocol.

  • Y

The ring does support the extended K1/K2/K3 protocol.

<NAME>

(Optional) NAME is a user-specified string to identify the facility.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<EXPTRC>

(Optional) Expected section trace content. Indicates the expected section trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). String data type.

<TRC>

(Optional) The section trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. Defaults to NULL. TRC is a string.

<TRCMODE>

(Optional) Section trace mode. Applicable only to VC-level paths in SDH (VCn). Defaults to the MAN mode. The parameter type is TRCMODE (trace mode).

  • AUTO

Use the previously received section trace string as the expected string. Not applicable to MXP/TXP cards.

  • AUTO-NO-AIS

Use the previously received section trace string as the expected string and do not turn on AIS and RDI if TIM-P is detected.

  • MAN

Use the provisioned expected string as the expected string.

  • MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected.

  • OFF

Turn off section trace capability. Nothing will be reported.

<TRCFORMAT>

(Optional) Trace message size. The parameter type is TRCFORMAT (trace format).

  • 1-BYTE

1 byte trace message

  • 16-BYTE

16 byte trace message

  • 64-BYTE

64 byte trace message

<ADMSSM>

(Optional) SSM selectable value. It will only appear when SSM is disabled. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SDH.

  • DUS_SDH

Do Not Use For Synchronization

  • G811

G811 Standard

  • RES_SDH

Reserved For Network Synchronization Use

  • G812T

G812T Standard

  • STU_SDH

Synchronized, Traceability Unknown

  • G812TL

G812TL Standard

  • SETS

Synchronous Equipment Timing Source

<SENDDUSFF>

(Optional) The parameter type is EXT_RING, which indicates whether the ring supports the extended K1/K2/K3 protocol.

  • N

The ring does not support the extended K1/K2/K3 protocol.

  • Y

The ring does support the extended K1/K2/K3 protocol.

<AISONLPBK>

(Optional) The parameter type is AIS_ON_LPBK, which indicates if AIS should be sent on loopback.

  • AIS_ONLPBK_FACILITY

AIS is sent on facility loopback.

  • AIS_ON_LPBK_ALL

AIS is sent on all loopbacks.

  • AIS_ON_LPBK_OFF

AIS is not sent on loopback.

  • AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopback.

<FREQ>

(Optional) The parameter type is OPTICAL_WLEN (optical wavelength).

  • 1310

Wavelength 1310

  • 1470

Wavelength 1470

  • 1490

Wavelength 1490

  • 1510

Wavelength 1510

  • 1529.55

Wavelength 1529.55

  • 1529.94

Wavelength 1529.94

  • 1530

Wavelength 1530

  • 1530.33

Wavelength 1530.33

  • 1530.73

Wavelength 1530.73

  • 1531.12

Wavelength 1531.12

  • 1531.51

Wavelength 1531.51

  • 1531.90

Wavelength 1531.90

  • 1532.29

Wavelength 1532.29

  • 1532.68

Wavelength 1532.68

  • 1533.07

Wavelength 1533.07

  • 1533.47

Wavelength 1533.47

  • 1533.86

Wavelength 1533.86

  • 1534.25

Wavelength 1534.25

  • 1534.64

Wavelength 1534.64

  • 1535.04

Wavelength 1535.04

  • 1535.43

Wavelength 1535.43

  • 1535.82

Wavelength 1535.82

  • 1536.22

Wavelength 1536.22

  • 1536.61

Wavelength 1536.61

  • 1537

Wavelength 1537

  • 1537.40

Wavelength 1537.40

  • 1537.79

Wavelength 1537.79

  • 1538.19

Wavelength 1538.19

  • 1538.58

Wavelength 1538.58

  • 1538.98

Wavelength 1538.98

  • 1539.37

Wavelength 1539.37

  • 1539.77

Wavelength 1539.77

  • 1540.16

Wavelength 1540.16

  • 1540.56

Wavelength 1540.56

  • 1540.95

Wavelength 1540.95

  • 1541.35

Wavelength 1541.35

  • 1541.75

Wavelength 1541.75

  • 1542.14

Wavelength 1542.14

  • 1542.35

Wavelength 1542.35

  • 1542.54

Wavelength 1542.54

  • 1542.94

Wavelength 1542.94

  • 1543.33

Wavelength 1543.33

  • 1543.73

Wavelength 1543.73

  • 1544.13

Wavelength 1544.13

  • 1544.53

Wavelength 1544.53

  • 1544.92

Wavelength 1544.92

  • 1545.32

Wavelength 1545.32

  • 1545.72

Wavelength 1545.72

  • 1546.12

Wavelength 1546.12

  • 1546.52

Wavelength 1546.52

  • 1546.92

Wavelength 1546.92

  • 1547.32

Wavelength 1547.32

  • 1547.72

Wavelength 1547.72

  • 1548.12

Wavelength 1548.12

  • 1548.51

Wavelength 1548.51

  • 1548.92

Wavelength 1548.92

  • 1549.32

Wavelength 1549.32

  • 1549.71

Wavelength 1549.71

  • 1550

Wavelength 1500

  • 1550.12

Wavelength 1550.12

  • 1550.52

Wavelength 1550.52

  • 1550.92

Wavelength 1550.92

  • 1551.32

Wavelength 1551.32

  • 1551.72

Wavelength 1551.72

  • 1552.12

Wavelength 1552.12

  • 1552.52

Wavelength 1552.52

  • 1552.93

Wavelength 1552.93

  • 1553.33

Wavelength 1553.33

  • 1553.73

Wavelength 1553.73

  • 1554.13

Wavelength 1554.13

  • 1554.13

Wavelength 1554.13

  • 1554.94

Wavelength 1554.94

  • 1555.34

Wavelength 1555.34

  • 1555.75

Wavelength 1555.75

  • 1556.15

Wavelength 1556.15

  • 1556.55

Wavelength 1556.55

  • 1556.96

Wavelength 1556.96

  • 1557.36

Wavelength 1557.36

  • 1557.77

Wavelength 1557.77

  • 1558.17

Wavelength 1558.17

  • 1558.58

Wavelength 1558.58

  • 1558.98

Wavelength 1558.98

  • 1559.39

Wavelength 1559.39

  • 1559.79

Wavelength 1559.79

  • 1560.20

Wavelength 1560.20

  • 1560.61

Wavelength 1560.61

  • 1561.01

Wavelength 1561.01

  • 1561.42

Wavelength 1561.42

  • 1561.83

Wavelength 1561.83

  • 1570

Wavelength 1570

  • 1570.83

Wavelength 1570.83

  • 1571.24

Wavelength 1571.24

  • 1571.65

Wavelength 1571.65

  • 1572.06

Wavelength 1572.06

  • 1572.48

Wavelength 1572.48

  • 1572.89

Wavelength 1572.89

  • 1573.30

Wavelength 1573.30

  • 1573.71

Wavelength 1573.71

  • 1574.13

Wavelength 1574.13

  • 1574.54

Wavelength 1574.54

  • 1574.95

Wavelength 1574.95

  • 1575.37

Wavelength 1575.37

  • 1575.78

Wavelength 1575.78

  • 1576.20

Wavelength 1576.20

  • 1576.61

Wavelength 1576.61

  • 1577.03

Wavelength 1577.03

  • 1577.44

Wavelength 1577.44

  • 1577.86

Wavelength 1577.86

  • 1578.27

Wavelength 1578.27

  • 1578.69

Wavelength 1578.69

  • 1579.10

Wavelength 1579.10

  • 1579.52

Wavelength 1579.52

  • 1579.93

Wavelength 1579.93

  • 1580.35

Wavelength 1580.35

  • 1580.77

Wavelength 1580.77

  • 1581.18

Wavelength 1581.18

  • 1581.60

Wavelength 1581.60

  • 1582.02

Wavelength 1582.02

  • 1582.44

Wavelength 1582.44

  • 1582.85

Wavelength 1582.85

  • 1583.27

Wavelength 1583.27

  • 1583.69

Wavelength 1583.69

  • 1584.11

Wavelength 1584.11

  • 1584.53

Wavelength 1584.53

  • 1584.95

Wavelength 1584.95

  • 1585.36

Wavelength 1585.36

  • 1585.78

Wavelength 1585.78

  • 1586.20

Wavelength 1586.20

  • 1586.62

Wavelength 1586.62

  • 1587.04

Wavelength 1587.04

  • 1587.46

Wavelength 1587.46

  • 1587.88

Wavelength 1587.88

  • 1588.30

Wavelength 1588.30

  • 1588.73

Wavelength 1588.73

  • 1589.15

Wavelength 1589.15

  • 1589.57

Wavelength 1589.57

  • 1589.99

Wavelength 1589.99

  • 1590

Wavelength 1590

  • 1590.41

Wavelength 1590.41

  • 1590.83

Wavelength 1590.83

  • 1591.26

Wavelength 1591.26

  • 1591.68

Wavelength 1591.68

  • 1592.10

Wavelength 1592.10

  • 1592.52

Wavelength 1592.52

  • 1592.95

Wavelength 1592.95

  • 1593.37

Wavelength 1593.37

  • 1593.79

Wavelength 1593.79

  • 1594.22

Wavelength 1594.22

  • 1594.64

Wavelength 1594.64

  • 1595.06

Wavelength 1595.06

  • 1595.49

Wavelength 1595.49

  • 1596.34

Wavelength 1596.34

  • 1596.76

Wavelength 1596.76

  • 1597.19

Wavelength 1597.19

  • 1597.62

Wavelength 1597.62

  • 1598.04

Wavelength 1598.04

  • 1598.47

Wavelength 1598.47

  • 1598.89

Wavelength 1598.89

  • 1599.32

Wavelength 1599.32

  • 1599.75

Wavelength 1599.75

  • 1600.06

Wavelength 1600.06

  • 1601.03

Wavelength 1601.03

  • 1601.46

Wavelength 1601.46

  • 1601.88

Wavelength 1601.88

  • 1602.31

Wavelength 1602.31

  • 1602.74

Wavelength 1602.74

  • 1603.17

Wavelength 1603.17

  • 1603.60

Wavelength 1603.60

  • 1604.03

Wavelength 1604.03

  • 1610

Wavelength 1610

  • USE-TWL1

Use Tunable Wavelength 1

<LOSSB>

(Optional) The parameter type is REACH, which is the reach value.

  • AUTOPROV

Autoprovisioning

  • CWDM

Coarse wavelength division multiplexing (CWDM)

  • CWDM-40KM

CWDM 40 kilometers.

  • CX

Reach CX

  • CX1

Reach CX1

  • DX

Reach DX

  • HX

Reach HX

  • I1

Reach I1

  • IR-1

Reach IR-1

  • IR-2

Reach IR-2

  • L1

Reach L1

  • L2

Reach L2

  • L3

Reach L3

  • LR-1

Reach LR-1

  • LR-2

Reach LR-2

  • LR-3

Reach LR-3

  • LX

Reach LX

  • S1

Reach S1

  • S2

Reach S2

  • SR

Reach SR

  • SR-1

Reach SR-1

  • SX

Reach SX

  • T

Reach T

  • TEN-GE-ER

10 GE extended range

  • TEN-GE-LR

10 GE long range

  • TEN-GE-SR

10 GE short range

  • ULH

Reach ULH

  • VSR

Reach VSR

  • VX

Reach VX

  • ZX

Reach ZX

<FOREIGNFEND>

(Optional) Indicates whether the far-end NE on the DCC is a foreign NE. The parameter type is ON_OFF (disable or enabled an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<FOREIGNIP>

(Optional) The IP address of the far-end NE on the DCC. Used only if FOREIGNFEND is Y. FOREIGNIP is a string.

<OPRNOMINAL >

Reads the current raw optical receive power and sets the raw OPR value as the nominal optical receive power.

  • N

Not Supported

  • Y

Sets the OPR

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AUTOMATICINSERVICE. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.9 ED-ALS

(Cisco ONS 15454 SDH) The Edit Automatic Laser Shutdown (ED-ALS) command is used to modify the automatic laser shutdown (ALS) attributes of an STM facility and all the facilities that support the ALS feature. For transponder and muxponder cards, this command is used to modify the ALS parameter of the STM16 and STM64 ports.

 
Usage Guidelines

The ED-ALS command is applicable for the following:

  • For all non-OTU payloads on 100G-LC-C, 10x10G-LC, and CFP-LC cards on the CHAN AID.
  • Payload interfaces for OTU enabled ports.

Category

Ports

Security

Provisioning

Input Format

ED-ALS[:<TID>]:<AID>:<CTAG>[:::ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>],[ALSRCPW=<ALSRCPW>],[OSRI=<OSRI>],[:];

Input Example

Cisco ONS 15454 SDH

ED-ALS:CISCO:FAC-4-1-1:1:::ALSMODE=AUTO,ALSRCINT=130,ALSRCPW=80.1;

 

Table 11-8 ED-ALS Command - Parameter Support

Input Parameters
Description

<SRC>

Access identifier from the “AidUnionId” section.

<ALSMODE>

(Optional) ALS is enabled or disabled. the parameter type is ALS_MODE, which is the working mode for automatic laser shutdown.

  • AUTO

Automatic

  • DISABLED

Disabled

  • MAN

Manual

  • MAN-RESTART

Manual restart for test

<ALSRCINT>

(Optional) ALS recovery interval. The range is 60 to 300 seconds. ALSRCINT is an integer.

<ALSRCPW>

(Optional) ALS recovery pulse width. The range is 80.0 to 100.00 seconds, in increments of 100 ms. ALSRCPW is a float.

11.10 ED-APC

(Cisco ONS 15454 SDH) The Edit Amplification Power Control (ED-APC) command is used to modify the APC application attributes. The default value for an optional parameter is the NE default value. The value might not be the current value for the parameter. Use a retrieve command to retrieve the current value.

 
Usage Guidelines

None

Category

DWDM

Security

Provisioning

Input Format

ED-APC[:<TID>]:<AID>:<CTAG>[::<ROLE>][:APCENABLE=<APCENABLE>][:];

Input Example

ED-APC:PENNGROVE:WDMSIDE-A:CTAG:::APCENABLE=N;

Table 11-9 ED-APC Command - Parameter Support

Input Parameters
Description

<WDMSIDE>

The AID is used to access the WDM side of an MSTP node.

  • WDMSIDE-{UNKNOWN,A,B,C,D,E,F,G,H}

MSTP side identifier

<ROLE>

The role the unit is playing in the protection group.

  • PROT

The entity is the protection unit in the protection group.

  • WORK

The entity is the working unit in the protection group.

<APCENABLE>

(Optional) Enable/disable the APC application. Default is N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

11.11 ED-AUTO

(Cisco ONS 15454 SDH, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Edit Auto (ED-AUTO) command is used to retrieve the AUTO port provisioned. Port bandwidth changes to OC3/OC12/OC48/1GE as per the incoming signal when auto sense is enabled. Default is OC48 when auto sense is disabled.

 
Usage Guidelines

None

Category

DWDM

Security

Provisioning

Input Format

ED-AUTO:[<TID>]:<AID>:<CTAG>::: AUTOSENSE=<AUTOSENSE>;

Input Example

ED-AUTO:CISCO:VFAC-2-1-1:CTAG:::AUTOSENSE=Y;

Input Parameters

<AID>

The AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID.

<AUTOSENSE>

Specifies if auto sense must be enabled or disabled.

  • Y

Enables auto sense.

  • N

Disables auto sense.

11.12 ED-BITS

(Cisco ONS 15454 SDH) The Edit Building Integrated Timing Supply (ED-BITS) command edits the building integrated timing supply (BITS) reference attributes.

 
Usage Guidelines

The SYNC-BITS1 and SYNC-BITS2 AIDs can be used to set the BITS-OUT port state.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Synchronization

Security

Provisioning

Input Format

Cisco ONS 15454 SDH

ED-BITS:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[SABIT=<SABIT>],[LBO=<LBO>], [SYNCMSG=<SYNCMSG>],[AISTHRSHLD=<AISTHRSHLD>], [BITSFAC=<BITSFAC>],[ADMSSM=<ADMSSM>][:<PST>];

Input Example

Cisco ONS 15454 SDH

ED-BITS:SONOMA:BITS-2:779:::LINECDE=AMI,FMT=E1-MF,SYNCMSG=N,
,SABIT=BYTE-5,BITSFAC=E1,ADMSSM=G811:UNLOCKED

 

Table 11-10 ED-BITS Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “BITS” section.

<LINECDE>

(Optional) Line code. The parameter type is LINE_CODE (line code).

  • AMI

Line code value is AMI.

  • B3ZS

Binary three-zero substitution.

  • B6ZS

Line code value is B6ZS.

  • B8ZS

Line code value is B8ZS.

  • HDB3

Line code value is HDB3. (Applicable only for SDH platform).

  • JBZS

JBZS

  • ZBTSI

ZBTSI

<FMT>

(Optional) Digital signal frame format. Defaults to E1-MF. The parameter type is FRAME_FORMAT, which is the frame format for an E1 port.

  • AUTOPROV

AUTOPROV

  • CBIT

C-BIT line type applies to the DS3XM and DS3E cards.

  • D4

Frame format is D4

  • DS2 FRAMED

DS2 FRAMED

  • E1-CRC

SDH E1 CRC frame format

  • E1-CRCMF

SDH E1 CRCMF frame format

  • E1-MF

SDH E1 MF frame

  • E1-FRAME

SDH E1-frame format

  • E1-UNFRAMED

SDH E1 unframed format

  • E2 FRAMED

E2 FRAMED

  • E3-FRAME

E3-FRAME

  • E3-PLCP

E3-PLCP

  • ESF

Frame format is ESF

  • FRAMENA

FRAMENA

  • G-751

G-751

  • G-832

G-832

  • M13

M13 line type applies to the DS3XM and DS3E cards.

  • M23

M23

  • SYNTRAN

SYNTRAN

  • UNFRAMED

Frame format is unframed

<IMPEDANCE>

(Optional) Impedance is the total opposition that a circuit presents to alternating current. The maximum power transfer that takes place from the source to load when the impedance match.

  • 120 ohms

120 ohm termination

  • 100 ohms

100 ohm termination

  • 75 ohms

75 ohm termination

<LBO>

(Optional) Line buildout settings. BITS line buildout. Default value is 0 to 133. LBO is an integer. The parameter type is BITS_LineBuildOut (BITS line buildout).

  • 0–133

BITS line buildout range is 0–133.

  • 134–266

BITS line buildout range is 134–266.

  • 267–399

BITS line buildout range is 267–399.

  • 400–533

BITS line buildout range is 400–533.

  • 534–655

BITS line buildout range is 534–655.

<SYNCMSG>

(Optional) Indicates whether the BITS facility supports synchronization status message. Default is on (Y). The parameter type is EXT_RING, which indicates whether the ring supports the extended K1/K2/K3 protocol.

  • N

The ring does not support the extended K1/K2/K3 protocol.

  • Y

The ring does support the extended K1/K2/K3 protocol.

<AISTHRSHLD>

(Optional) Alarm indication signal threshold. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SDH.

  • DUS_SDH

Do Not Use For Synchronization

  • G811

G811 Standard

  • RES_SDH

Reserved For Network Synchronization Use

  • G812T

G812T Standard

  • STU_SDH

Synchronized, Traceability Unknown

  • G812TL

G812TL Standard

  • SETS

Synchronous Equipment Timing Source

<SABIT>

(Optional) When the frame format selection is E1, SABIT is the bit used to receive and transmit the SSM. The parameter type is SABITS (SA BITS).

  • BYTE-4

SABIT is BYTE-4.

  • BYTE-5

SABIT is BYTE-5.

  • BYTE-6

SABIT is BYTE-6.

  • BYTE-7

SABIT is BYTE-7.

  • BYTE-8

SABIT is BYTE-8.

<BITSFAC>

(Optional) BITS facility settings. BITS-2 always inherits the value of BITS-1. The parameter type is BITS_FAC, which is the BITS facility rate.

  • 2 M

2 MHz rate

  • 64 K

64 K rate

  • 6 M

6 MHz rate

  • E1

E1 rate

<ADMSSM>

(Optional) SSM selectable. Only applicable to BITS-IN when SSM is disabled. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SDH.

  • DUS_SDH

Do Not Use For Synchronization

  • G811

G811 Standard

  • RES_SDH

Reserved For Network Synchronization Use

  • G812T

G812T Standard

  • STU_SDH

Synchronized, Traceability Unknown

  • G812TL

G812TL Standard

  • SETS

Synchronous Equipment Timing Source

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

11.13 ED-BULKROLL-<STM_TYPE>

(Cisco ONS 15454 SDH) The Edit Bulkroll for STM4, STM64, STM1, and STM16 command edits information about the rolling of traffic from one endpoint to another without interrupting service. This uses the FORCE option to force a valid signal. The only parameters that can be edited are RMODE and FORCE. The time slots cannot be edited. Use ED-ROLL-<MOD_PATH> for single path level rolling. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

None

Category

Bridge and Roll

Security

Provisioning

Input Format

ED-BULKROLL-<STM_TYPE>:[<TID>]:<FROM>:<CTAG>:::
[RFROMSTART=<RFROMSTART>],[RTOSTART=<RTOSTART>],
[RFROMEND=<RFROMEND>],[CMDMDE=<CMDMDE>];

Input Example

ED-BULKROLL-STM16:CISCO:FAC-1-1:1:::RFROMSTART=VC3-1-1-1,
RTOSTART=VC3-1-1-1,RFROMEND=VC3-1-1-1,CMDMDE=FRCD;

 

Table 11-11 ED-ROLL-<MOD_PATH> Command - Parameter Support

Input Parameters
Description

<FROM>

One of the end points. Access identifier from the “FACILITY” section for line level rolling and bulk rolling. Must not be null.

<RFROMSTART>

(Optional) The starting time slot in the source roll port. For bulk rolling only. The AID is from the “CrossConnectId1” section (VC or VC11).

<RFROMEND>

(Optional) The ending time slot in the source roll port. For bulk rolling only. The AID is from the “CrossConnectId1” section (VC or VC11).

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

11.14 ED-BWP-ETH

(Cisco ONS 15454 SDH) This command is used to modify a Bandwidth Profile entry in BWP DB. The BWP DB is a collection of BWP used in a Network Element.

 
Usage Guidelines

Error conditions for deleting bandwidth profile can be:

  • Invalid AID. If the AID is invalid, an IIAC (Invalid AID) error message is returned.
  • The "ALL" AID is invalid for this command.
  • The BWP having the specified AID should be present in the node, that is, already been entered by ENT-BWP-ETH command.

Category

ETHERNET

Security

Provisioning

Input Format

ED-BWP-ETH:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[CIR=<CIR>],[CBS=<CBS>],[PBS=<PBS>],[PIR=<PIR>],[CFMSTATE=<CFM_STATE>][:];

Input Example

ED-BWP-ETH:ROCKS:BWP-10000:1:::NAME="MyBWP",CIR=10,CBS=1M,PBS=1M,PIR=20,CFMSTATE=Y;

Input Parameters

 

Table 11-12 ED-BWP-ETH Command - Parameter Support

Input Parameters
Description

<AID>

This AID is used to access BWP.

  • BWP-ALL

All aid for BWP.

  • BWP-{1-10000}

Single AID for BWP. The valid identifiers ranges from 1 to 10000.

<NAME>

The BWP name. BWP name is a String.

<CIR>

Ingress committed information rate. This is a value between 0.0 and 100.0. Default value is 100.0.

<CBS>

Ingress committed burst bucket size.

  • 4K

4 Kbit bucket size

  • 8K

16 Kbit bucket size

  • 16K

32 Kbit bucket size

  • 32K

64 Kbit bucket size

  • 64K

128 Kbit bucket size

  • 128K

256 Kbit bucket size

  • 256K

512 Kbit bucket size

  • 512K

1 Mbit bucket size

  • 1M

2 Mbit bucket size

  • 2M

4 Mbit bucket size

  • 4M

8 Mbit bucket size

  • 8M

16 Mbit bucket size

  • 16M

16 Kbit bucket size

<PBS>

Ingress peak burst bucket size

  • 4K

4 Kbit bucket size

  • 8K

8 Kbit bucket size

  • 16K

16 Kbit bucket size

  • 32K

32 Kbit bucket size

  • 64K

64 Kbit bucket size

  • 128K

128 Kbit bucket size

  • 256K

256 Kbit bucket size

  • 512K

512 Kbit bucket size

  • 1M

1 Mbit bucket size

  • 2M

2 Mbit bucket size

  • 4M

4 Mbit bucket size

  • 8M

8 Mbit bucket size

  • 16M

16 Mbit bucket size

<PIR>

Peak information rate. This is a value between 0.0 and 100.0. Default value is 100.0.

<CFMSTATE>

Link Integrity status

  • Y

Enabled

  • N

Disabled

11.15 ED-CFM

(Cisco ONS 15454 SDH) The Edit Connectivity Fault Management (ED-CFM) command edits the Connectivity Fault Management (CFM) protocol at the port level.

 
Usage Guidelines

  • This command is applicable only to GE_XP and 10GE_XP cards.
  • The card should be in Layer2 over DMDM mode.

Category

Port

Security

Provisioning

Input Format

ED-CFM:[<TID>]:<AID>:<CTAG>;

Input Example

ED-CFM:454-156:ETH-1-1-1:1:::CFMSTATE=enable;

Input Parameters

Table 11-13 ED-CFM Command - Parameter Support

Input Parameters
Description

<AID>

Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “ETH” section.

<CFM_STATE>

Indicates whether the CFM is enabled or disabled on the port.

  • ENABLE

Indicates the CFM is enabled on the port.

  • DISABLE

Indicates the CFM is disabled on the port.

11.16 ED-CHGRP

(Cisco ONS 15454 SDH) The Edit Channel Group (ED-CHGRP) command edits the layer 2 channel group information of GE_XP and 10GE_XP ethernet cards.

 
Usage Guidelines

The default values for all optional parameters are network element (NE) default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Channel Group

Security

Provisioning

Input Format

ED-CHGRP:[<TID>]:<AID>:<CTAG>:::[ATTACH=<ATTACH>],[DETACH=<DETACH>],[LACPMODE=<LACPMODE>],[HASHALGO=<HASHALGO>],[NIMODE=<NIMODE>],[MACLEARNING=<MACLEARNING>],[INGRESSCOS=<INGRESSCOS>],[ETHERCETYPE=<ETHERCETYPE>],[ETHERSTYPE=<ETHERSTYPE>],[BPDU=<BPDU>],[QNQMODE=<QNQMODE>],[TRNSPSVLAN=<TRNSP_SVLAN>],[MTU=<MTU>],[FLOWCONTROL=<FLOWCONTROL>],[SPEED=<SPEED>],[EXPSPEED=<EXPSPEED>],[CIR=<CIR],[CBS=<CBS>],[EBS=<EBS>]:[<PST>[,<SST>]];;

Input Example

ED-CHGRP::CHGRP-12-2:1:::ATTACH=ETH-12-5-1&ETH-12-1-1,LACPMODE=ON,HASHINGALGO=HASHING-UCAST-SA-DA-VLAN-INCOMING-PORT,NIMODE=UNI,MACLEARNING=Y,INGRESSCOS=0,ETHERCETYPE=8100,ETHERSTYPE=8100,BPDU=Y,QNQMODE=SELECTIVE,MTU=9700,FLOWCTRL=ASYMMETRIC,SPEED=10_GBPS,EXPSPEED=1_GBPS,CIR=100,CBS=4K,EBS=4k;

 

Table 11-14 ED-CHGRP Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “CHGRP” section.

<NIMODE>

Identifies the Ethernet Network Interface Mode.

  • NNI

(Default) Network-Network Interface Mode

  • UNI

User-Network Interface Mode

<LACPMODE>

LACP mode values

  • ON

Manual mode of LACP

  • ACTIVE

Active mode of LACP

  • PASSIVE

Passive mode of LACP

<HASHINGALGO>

Hashing algorithm value

  • HASHING_SA_VLAN_INCOMING_PORT

The Hashing Algorithm value is HASHING_SA_VLAN_INCOMING_PORT.

  • HASHING_DA_VLAN_INCOMING_PORT

The Hashing Algorithm is HASHING_DA_VLAN_INCOMING_PORT.

  • HASHING_SA_DA_VLAN_INCOMING_PORT

The Hashing Algorithm is HASHING_SA_DA_VLAN_INCOMING_PORT.

  • HASHING_SRC_IP_TCP_UDP

The Hashing Algorithm is HASHING_SRC_IP_TCP_UDP.

  • HASHING_DST_IP_TCP_UDP

The Hashing Algorithm is HASHING_DST_IP_TCP_UDP

  • HASHING_SRC_DST_ IP_TCP_UDP

The Hashing Algorithm is HASHING_SRC_DST_IP_TCP_UDP.

<MTU>

(Optional) Maximum transport unit. The parameter type is MTU_TYPE, which indicates the maximum transport unit used by an Ethernet card. Defaults to 9600.

  • 10004

10004. Indicates jumbo size.

  • 1500

1500

  • 1548

1548

  • 9600

9600. Indicates jumbo size.

  • 64

64

  • 9700

9700. Indicates jumbo size.

<ATTACH >

Ethernet AID for the ethernet port on GE_XP and 10GE_XP card.

<DETACH>

To remove or detach the port.

<SPEED>

(Optional) The parameter type is ETHER_SPEED, which indicates Ethernet speed. Defaults to AUTO.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 10_MBPS

10 Megabits per second

  • 1_GBPS

1 Gigabit per second

  • 40_GBPS

40 Gigabit per second

  • AUTO_FDX

Enable auto negotiation with full duplex.

<EXPSPEED>

(Optional) Ethernet speed. The parameter type is ETHER_SPEED, which is the Ethernet speed.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 10_MBPS

10 Megabits per second

  • 1_GBPS

1 Gigabit per second

  • AUTO

Auto

<CIR>

Ingress committed information rate. The value ranges from 0.0 to 100.0. The default value is 100.0.

<CBS>

Ingress committed burst bucket size.

  • 4K

4 Kbit bucket size

  • 8K

16 Kbit bucket size

  • 16K

32 Kbit bucket size

  • 32K

64 Kbit bucket size

  • 64K

128 Kbit bucket size

  • 128K

256 Kbit bucket size

  • 256K

512 Kbit bucket size

  • 512K

1 Mbit bucket size

  • 1M

2 Mbit bucket size

  • 2M

4 Mbit bucket size

  • 4M

8 Mbit bucket size

  • 8M

16 Mbit bucket size

  • 16M

16 Kbit bucket size

<EBS>

Ingress excess burst bucket size.

<MACLEARNING>

MAC Address Learning Mode. This activates the MAC address learning on the interface to avoid packet broadcasting.

  • Y

Enables the MAC learning on the interface.

  • N

Disables the MAC learning on the interface.

<INGRESSCOS>

Identifies the COS value set in the S-VLAN tag.

  • 0 to 7

Set a Cos value

  • TRUST

Use the Customer COS

  • VLAN

The COS will be provisioned on CVLAN basis (QinQ selective mode)

<ETHERCETYPE>

Identifies a customer foreseen Ethernet type. If the customer uses a non-standard Ethernet type, the incoming packets will be accepted only if the CE-VLAN Ethernet type matches this parameter.

<ETHERSTYPE>

Identifies a customer foreseen Ethernet type. If the customer uses a non-standard Ethernet type, the incoming packets will be accepted only if the CE-VLAN Ethernet type matches this parameter.

<BPDU>

BPDU (Bridge Protocol Data Unit) management mode; Drop/Passthrough BPDU tagged packets.

  • Y

Enables the BPDU tag.

  • N

Disables the BPDU tag.

<QNQMODE>

This is used to represent the QinQ mode operations.

  • Selective

The S-VLAN tag is added only on specified CE-VLANs. The other packets are dropped.

  • Transparent

The S-VLAN tag is always performed where all packets having the S-VLAN-ID identified by TRNSPSVLAN parameter are allowed.

<TRNSPSVLAN>

VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs.

<NAME>

(Optional) NAME is a string. User-assigned port name.

11.17 ED-CMD-SECU

(Cisco ONS 15454 SDH) The Edit Command Security (ED-CMD-SECU) command edits the command security level of a particular command.

 
Usage Guidelines

None

Category

Security

Security

Superuser

Input Format

ED-CMD-SECU:[<TID>]:<AID>:<CTAG>::<CAP>;

Input Example

ED-CMD-SECU::INIT-REG:1::SUPER;

 

Table 11-15 ED-CMD-SECU Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier string. Identifies the entity in the NE to which the command pertains. It is the command verb along with verb modifier(s), as it currently exists. It can be a single command or a block of commands, where the block could include all commands. Only INIT-REG will be supported. AID is a string. It must not be null.

<CAP>

Command access privilege. It must not be null. The parameter type is PRIVILEGE, which is the security level.

  • PROV

Provision security level. 60 minutes of idle time.

  • SUPER

Superuser security level. 15 minutes of idle time.

  • ROOT_USER

Root user.

  • SEC_SUPER

Security super user.

  • SEC_USER

Security user.

11.18 ED-COS-ETH

(Cisco ONS 15454 SDH) The Edit Cost of Service Ethernet (ED-COS-ETH) command edits the egress parameter of a CoS table associated to an L2 Ethernet port.

 
Usage Guidelines

The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ethernet

Security

Provisioning

Input Format

ED-COS-ETH:[<TID>]:<AID>:<CTAG>:::[QOSENABLED=<QOSENABLED>],[BW0=<BWO>],
[WEIGHT0=<WEIGHT0>],[BW1=<BW1>],[WEIGHT1=<WEIGHT1>],[BW2=<BW2>],
[WEIGHT2=<WEIGHT2>],[BW3=<BW3>],[WEIGHT3=<WEIGHT3>],[BW4=<BW4>],
[WEIGHT4=<WEIGHT4>],[BW5=<BW5>],[WEIGHT5=<WEIGHT5>],[BW6=<BW6>],
[WEIGHT6=<WEIGHT6>],[BW7=<BW7>],[WEIGHT7=<WEIGHT7>][:];

Input Example

ED-COS-ETH:PETALUMA:ETH-1-1-1:1:::QOSENABLED=Y,BW0=10,WEIGHT0=0,BW1=20,
WEIGHT1=2,BW2=40,WEIGHT2=4,BW3=60,WEIGHT3=6,BW4=70,WEIGHT4=8,BW5=80,
WEIGHT5=10,BW6=85,WEIGHT6=12,BW7=100,WEIGHT7=15:;

 

Table 11-16 ED-COS-ETH Command - Parameter Support

Input Parameters
Description

<AID>

Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “FACILITY” section.

<QOSENABLED>

Used to enable or disable the egress QOS policy of an L2 Ethernet port.

  • N

Disable the service.

  • Y

Enable the service.

<BW0>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT0>

Value represents the weighted round-robin (WRR) weight associated to the COS values, an integer value between 0 and 15.

<BW1>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT1>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW2>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT2>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW3>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT3>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW4>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT4>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW5>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT5>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW6>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT6>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

<BW7>

Bandwidth percentage, a value between 0 and 100.

<WEIGHT7>

Value represents the WRR weight associated to the COS values, an integer value between 0 and 15.

11.19 ED-CRS-<PATH>

(Cisco ONS 15454 SDH) The Edit Cross-Connection for VC3, VC44C, VC38C, VC464C, VC48C, VC4, VC416C, VC42C, VC43C, VC11, or VC12 (ED-CRS-<PATH>) command edits a cross-connect. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

  • ADD and REMOVE cannot be used together. The example provided is for informational purposes only. ADD and REMOVE are mutually exclusive.
  • Add/Remove drops is possible only on ONEWAY, SNCP_DROP, SNCP_DC, and SNCP_EN type of cross-connects (one-way only).
  • Traditional cross-connections cannot be upgraded to DRI cross-connections using the ED_CRS command.
  • CKTID is a string of ASCII characters. The maximum length of CKTID is 48. If the CKTID is EMPTY or NULL, this field will not appear.
  • The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
  • You cannot add or drop onto unidirectional connections on MS-SPRing DRI primary or secondary nodes.

Category

Cross Connections

Security

Provisioning

Input Format

ED-CRS-<PATH>:[<TID>]:<SRC>,<DST>:<CTAG>::[<CCT>]:[ADD=<ADD>],
[REMOVE=<REMOVE>],[CKTID=<CKTID>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-CRS-VC4::VC4-1-1-1,VC4-2-1-1:1:::ADD=VC4-13-1-1,REMOVE=VC4-2-1-1,CKTID=CKTID
CMDMDE=FRCD:UNLOCKED,AUTOMATICINSERVICE;

 

Table 11-17 ED-CRS-<PATH> Command- Parameter Support

Input Parameters
Description

<SRC>

Source AID from the “CrossConnectId1” section.

<DST>

Destination AID from the “CrossConnectId1” section.

<CCT>

(Optional) Type of connection. Used for specifying one or two-way connections. The parameter type is CCT, which is the type of cross-connect to be created.

  • 1WAY

A unidirectional connection from a source tributary to a destination tributary

  • 1WAYDC

SNCP multicast drop (one-way continue)

  • 1WAYEN

SNCP multicast end node (one-way continue)

  • 1WAYMON

A bidirectional connection between the two tributaries

Note 1WAYMON is not supported with TL1. However, it is still supported from Cisco Transport Controller (CTC). Using CTC, you can create 1WAYMON cross-connects and can be retrieved through TL1.

  • 1WAYPCA

A unidirectional connection from a source tributary to a destination tributary on the protection path/fiber

  • 2WAY

A bidirectional connection between the two tributaries

  • 2WAYDC

A bidirectional drop-and-continue connection applicable only to SNCP traditional and integrated DRIs

  • 2WAYPCA

A bidirectional connection between the two tributaries on the extra protection path/fiber

  • DIAG

Diagnostics cross-connect. Supports BERT (MS-SPRing PCA diagnostics cross-connect).

<ADD>

(Optional) AID from the “AidUnionId” section.

<REMOVE>

(Optional) AID from the “AidUnionId” section.

<CKTID>

(Optional) Circuit identification that contains the common language Circuit ID or other alias of the circuit being provisioned. Cannot contain blank spaces. CKTID is a string of ASCII characters. The maximum length of CKTID can be 48.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.20 ED-CRS-ETH

(Cisco ONS 15454 SDH) This command modifies an ethernet connection relationship between two or more ethernet connection end points inside the ethernet facilities.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values may not be the current value for a parameter. In order to obtain the current value use RTRV-XX command to retrieve them.

The ethernet connection end point identifier must be the same for all the ethernet ports inside the connection and must be kept the same for all the ethernet circuit.

CKTID is a string of ASCII characters. The maximum length of CKTID can be 48. If the CKTID is EMPTY or NULL this field is not displayed

If the AID is invalid, an IIAC (Invalid AID) error message is returned.

The "ALL" AID is invalid for this command.

Category

ETHERNET

Security

Provisioning

Input Format

ED-CRS-ETH:[<TID>]:<SRC>,<DST>:<CTAG>:::[ADD=<ADD>],[REMOVE=<REMOVE>],[CKTID=<CKTID>][:];

Input Example

ED-CRS-ETH:KARTHIK:ETH-1-1-1-12,ETH-1-21-1-12:1:::CKTID=NEW,ADD=ETH-1-2-1;

 

Table 11-18 ED-CRS-ETH Command - Parameter Support

Input Parameters
Description

<SRC>

Ethernet connection identifier AIDs used to access L2 ethernet connection end point.

  • ALL

The ALL aid is applicable for RTRV-only commands, basically the RTRV-rr type of commands.

  • ETHID[-{1-12}]-{1-5,12-16}-{1-22}-1-{1-20}

Ethernet connection end point aid for GE-XP card.

  • ETHID[-{1-12}]-{1-6,12-17}-{1-4}-1-{1-20}

Facility AID for 10GE-XP card.

<DST>

Ethernet connection identifier AIDs are used to access L2 ethernet connection end point

  • ALL

The ALL aid is applicable for RTRV-only commands, basically the RTRV-rr type of commands.

  • ETHID[-{1-12}]-{1-5,12-16}-{1-22}-1-{1-20}

Ethernet connection end point aid for GE-XP card.

  • ETHID[-{1-12}]-{1-6,12-17}-{1-4}-1-{1-20}

Facility aid for 10GE-XP card.

<ADD>

The AID AidUnionId. Default value is - NULL

<REMOVE>

The AID AidUnionId. Default value is - "NULL".

<CKTID>

Circuit identification parameter contains the Common Language Circuit ID or other alias of the circuit being provisioned. Default value is - "NULL"

11.21 ED-DAT

(Cisco ONS 15454 SDH) The Edit Date and Time (ED-DAT) command edits the date and time.

 
Usage Guidelines

None

Category

System

Security

Provisioning

Input Format

ED-DAT:[<TID>]::<CTAG>::[<DATE>],[<TIME>];

Input Example

ED-DAT:CISCO::1234::99-12-21,14-35-15;

Input Parameters

<DATE>

(Optional) Date. DATE is a string.

<TIME>

(Optional) Time. TIME is a string.

11.22 ED-DS3I

(Cisco ONS 15454 SDH) The Edit DS3I (ED-DS3I) command edits the attributes of a DS3i-N-12 facility.

 
Usage Guidelines

The following actions will return error messages:

  • Sending this command to edit TACC and any other attribute while the port has a cross-connection or the port/VT has a test access point (TAP or TACC Number) will return the IPNC (Parameters Not Compatible) error message.
  • Editing the TACC through the ED-xxx command is only allowed if there are no circuits or cross-connects on the port and the port or VT does not have a test access point (TAP or TACC Number). Otherwise, an error message will be returned.

Note • This command is not allowed if the card is a protect card. TACC creation will be denied on protect ports/cards.

  • Automatic application of loopbacks originating from the far end can be inhibited on the ports of a DS3i-N-12 card.
  • The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.


 

You cannot directly transition a facility from IS to Locked-Disabled,DSBLD service state. You can transition a facility to Locked-Disabled,DSBLD service state from any state except Locked-Disabled,Maintenance. To transition a facility from Locked-Disabled,Maintenance to Locked-Disabled,DSBLD service state, all the following conditions must be met:

  • The facility is not sourcing a synchronization clock
  • The facility's DCC is disabled
  • The facility is not part of a protection group
  • The facility is not supporting cross-connects
  • The facility is not using overhead connections or overhead terminations (such as express orderwire, local orderwire, or user data channels [UDCs])

Note The conditions stipulated can be overridden by using the CMDMDE=FRCD option. The FRCD option will immediately remove the facility from service (except for IS to Locked-Disabled,DSBLD transition) with no consideration for orderly interruption.


Category

Ports

Security

Provisioning

Input Format

ED-DS3I:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>],
[INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SFBER=<SFBER>],
[SDBER=<SDBER>],[SOAK=<SOAK>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-DS3I:CISCO:FAC-1-2:1:::FMT=C-BIT,LINECDE=B8ZS,LBO=0-255,INHFELPBK=N,
TACC=8,TAPTYPE=SINGLE,SFBER=1E-4,SDBER=1E-6,SOAK=10,NAME="DS3I PORT",
CMDMDE=NORM:UNLOCKED,AUTOMATICINSERVICE;

 

Table 11-19 ED-DS3I Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

  • C-BIT

C-BIT line type applies to the DS3i-N-12 cards.

  • M13

M13 line type applies to the DS3i-N-12 cards.

  • UNFRAMED

Line type is unframed.

<LINECDE>

(Optional) Line code. Defaults to B8ZS. The parameter type is DS_LINE_CODE.

  • AMI

Line code value is AMI.

  • B8ZS

Line code value is B8ZS.

  • HDB3

Line code value is HDB3.

<LBO>

(Optional) Line buildout settings. LBO is an integer. Defaults to 0–255. The parameter type is E_LBO, which is the electrical signal line buildout.

  • 0–225

Electrical signal line buildout range is 0–225.

  • 226–450

Electrical signal line buildout range is 226–450.

<INHFELPBK>

(Optional) Far-end loopback inhibition attribute of the port. If it is Y, the automatic far-end loopbacks are inhibited. It is either on or off. Defaults to Y. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<TACC>

(Optional) TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. TACC is an integer.

<TAPTYPE>

(Optional) TAP type. The parameter type is TAPTYPE, which is the test access point type.

  • DUAL

Dual FAD

  • SINGLE

Single FAD

<SFBER>

(Optional) Signal failure threshold. Defaults to 1E-4. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.

  • 1E-3

SFBER is 1E-3.

  • 1E-4

SFBER is 1E-4.

  • 1E-5

SFBER is 1E-5.

<SDBER>

(Optional) Signal degrade threshold. Defaults to 1E-7. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.

  • 1E-5

SDBER is 1E-5.

  • 1E-6

SDBER is 1E-6.

  • 1E-7

SDBER is 1E-7.

  • 1E-8

SDBER is 1E-8.

  • 1E-9

SDBER is 1E-9.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. Defaults to 32. SOAK is an integer.

<NAME>

(Optional) Maximum length is 32 characters. NAME is a string. Defaults to Null.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Not assigned

  • NotInstalled

Unequipped

11.23 ED-DSCP-<MOD2>

(Cisco ONS 15454 SDH) The Edit ETH or CHGRP (ED-DSCP-<MOD2>) command edits Differentiated Service Code Points (DSCP) to COS conversion table associated to a L2 ethernet port or a channel group.

 
Usage Guidelines

This command is applicable when the INGRESSCOS parameter is set to DSCP value on the ethernet port or channel group.

Category

Ethernet or Channel Group

Security

Provisioning

Input Format

ED-DSCP-MOD2:[<TID>]:<AID>:<CTAG>::<COS>:DSCPFIRST=<DSCP_FIRST>,DSCPLAST=<DSCP_LAST>[:];

Input Example

ED-DSCP-ETH::ETH-5-1-1:1234::3:DSCPFIRST=26,DSCPLAST=30;

ED-DSCP-CHGRP::CHGRP-5-1:1::3:DSCPFIRST=26,DSCPLAST=30;

Table 11-20 ED-DSCP-MOD2 Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier.

  • Ethernet

Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “ETH” section.

  • Channel Group

Access identifier from the “CHGRP” section.

<INGRESSCOS>

Identifies the COS value set in the S-VLAN tag.

  • 0 to 7

Set a Cos value

  • DSCP

The COS is set according to DSCP to COS mapping table.

  • TRUST

Use the Customer COS

  • VLAN

The COS will be provisioned on CVLAN basis (QinQ selective mode)

<DSCPFIRST>

DSCP range. Indicates a DSCP value used in the ethernet frame to define the QoS in L3 ethernet transport. It is a number in the range 0..64. Default values is 0

<DSCPLAST>

DSCP range. Indicates a DSCP value used in the ethernet frame to define the QoS in L3 ethernet transport. It is a number in the range 0..64. Default values is 0.

11.24 ED-E1

(Cisco ONS 15454 SDH) The Edit E1(ED-E1) command edits the attributes of an E1 facility.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Sending this command to edit TACC and any other attribute while the port has a cross-connect or the port/VT has a test access point (TAP or TACC Number), will return the IPNC (Parameters Not Compatible) error message.


NoteTACC creation will be denied on the protect ports/cards.


You cannot directly transition a facility from IS to Locked-Disabled,DSBLD service state. You can transition a facility to Locked-Disabled,DSBLD service state from any state except Locked-Disabled,Maintenance. To transition a facility from Locked-Disabled,Maintenance to Locked-Disabled,DSBLD service state, all the following conditions must be met:

  • The facility is not sourcing a synchronization clock
  • The facility's DCC is disabled
  • The facility is not supporting cross-connects

Note The conditions stipulated can be overridden by using the CMDMDE=FRCD option. The FRCD option will immediately remove the facility from service (except for IS to Locked-Disabled,DSBLD transition) with no consideration for orderly interruption.


Category

Ports

Security

Provisioning

Input Format

ED-E1[:<TID>]:<AID>:<CTAG>[:::CLKSRC=<CLKSRC>],[LINECDE=<LINECDE>],[FMT=<FMT>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SFBER=<SFBER>],[SDBER=<SDBER>],[SOAK=<SOAK>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[ADMSSM=<ADMSSM>],[SABIT=<SABIT>][:<PST>[,<SST>]];

Input Example

ED-E1:CISCO:FAC-2-1:1:::LINECDE=HDB3,FMT=E1-MF,TACC=8,TAPTYPE=SINGLE,
SFBER=1E-4,SDBER=1E-6,SOAK=10,NAME="E1 PORT",CMDMDE=NORM,
SYNCMSG=N,SENDDUS=N,RETIME=Y,ADMSSM=STU_SDH,
SABIT=BYTE-4:UNLOCKED,AUTOMATICINSERVICE;

Table 11-21 ED-E1 Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<CLKSRC>

Clock source

  • INTERNAL

INTERNAL

  • LOOPBACK TIMING

LOOPBACK TIMING

  • SYNCE

SYNCE

  • ADAPTIVE

ADAPTIVE

<LINECDE>

(Optional) Line code. Defaults to HDB3. The parameter type is LINE_CODE (line code). (Applicable only for SDH platform).

  • AMI

Line code value is AMI.

  • B3ZS

Binary three-zero substitution.

  • B6ZS

Line code value is B6ZS.

  • B8ZS

Line code value is B8ZS.

  • HDB3

Line code value is HDB3. (Applicable only for SDH platform).

  • JBZS

JBZS

  • ZBTSI

ZBTSI

<FMT>

(Optional) Digital signal frame format. Defaults to E1-MF. The parameter type is FRAME_FORMAT, which is the frame format for an E1 port.

  • AUTOPROV

AUTOPROV

  • CBIT

C-BIT line type applies to the DS3XM and DS3E cards.

  • D4

Frame format is D4

  • DS2 FRAMED

DS2 FRAMED

  • E1-CRCMF

SDH E1 CRCMF frame format

  • E1-MF

SDH E1 MF frame

  • E1-UNFRAMED

SDH E1 unframed format

  • E2 FRAMED

E2 FRAMED

  • E3-FRAME

E3-FRAME

  • E3-PLCP

E3-PLCP

  • ESF

Frame format is ESF

  • FRAMENA

FRAMENA

  • G-751

G-751

  • G-832

G-832

  • M13

M13 line type applies to the DS3XM and DS3E cards.

  • M23

M23

  • SYNTRAN

SYNTRAN

  • UNFRAMED

Frame format is unframed

<TACC>

(Optional) TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. TACC is an integer.

<TAPTYPE>

(Optional) TAP type. Defaults to DUAL. The parameter type is TAPTYPE, which is the test access point type.

  • DUAL

Dual FAD

  • SINGLE

Single FAD

  • 1E-5

SDBER is 1E-5.

  • 1E-6

SDBER is 1E-6.

  • 1E-7

SDBER is 1E-7.

  • 1E-8

SDBER is 1E-8.

  • 1E-9

SDBER is 1E-9.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. Defaults to 32. SOAK is an integer.

<NAME>

(Optional) NAME is a string. Defaults to NULL. Maximum length is 32 characters.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<SYNCMSG>

(Optional) Synchronization status messaging is enabled or disabled on the E1 facility. Defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

No

  • Y

Yes

<SENDDUS>

(Optional) The facility will send the DUS value as the synchronization status message for that facility. Defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

No

  • Y

Yes

<RETIME>

(Optional) Indicates if retiming is needed. Defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

No

  • Y

Yes

<ADMSSM>

(Optional) The administrative synchronization status message. Defaults to STU_SDH. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level.

  • DUS

Do Not Use For Synchronization

  • PRS

Primary Reference Source, Stratum 1 Traceable

  • DUS_SDH

Do Not Use For Synchronization

  • G811

G811 Standard

  • G812T

G812T Standard

  • STU_SDH

Synchronized, Traceability Unknown

  • G812TL

G812TL Standard

  • SETS

Synchronous Equipment Timing Source

<SABIT>

(Optional) When the frame format selection is E1, SABIT is the bit used to receive and transmit the SSM. The parameter type is SABITS (SA BITS).

  • BYTE-4

SABIT is BYTE-4.

  • BYTE-5

SABIT is BYTE-5.

  • BYTE-6

SABIT is BYTE-6.

  • BYTE-7

SABIT is BYTE-7.

  • BYTE-8

SABIT is BYTE-8.

<PST>

(Optional) Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.25 ED-E3

(Cisco ONS 15454 SDH) The Edit E3 (ED-E3) command edits the attributes of an E3 facility.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Sending this command to edit TACC and any other attribute while the port has a cross-connect or the port or VT has a test access point (TAP or TACC Number) will return the IPNC (Parameters Not Compatible) error message.


NoteTACC creation will be denied on the protect ports and cards.


You cannot directly transition a facility from IS to Locked-Disabled,DSBLD service state. You can transition a facility to Locked-Disabled,DSBLD service state from any state except Locked-Disabled,Maintenance. To transition a facility from Locked-Disabled,Maintenance to Locked-Disabled,DSBLD service state, all the following conditions must be met:

  • The facility is not sourcing a synchronization clock
  • The facility's DCC is disabled
  • The facility is not supporting cross-connects

Note The conditions stipulated can be overridden by using the CMDMDE=FRCD option. The FRCD option will immediately remove the facility from service (except for IS to Locked-Disabled,DSBLD transition) with no consideration for orderly interruption.


Category

Ports

Security

Provisioning

Input Format

Cisco ONS 15454

ED-E3[:<TID>]:<AID>:<CTAG>[:::CLKSRC=<CLKSRC>],[FMT=<FMT>],[LINECDE=<LINECDE>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SFBER=<SFBER>],[SDBER=<SDBER>],[SOAK=<SOAK>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[AISONLPBK=<AISONLPBK>][:<PST>[,<SST>]];

Input Example

Cisco ONS 15454

ED-E3:CISCO:E3-1-2:1:::TACC=8,TAPTYPE=SINGLE,SFBER=1E-4,SDBER=1E-6,SOAK=10,
NAME="E3 PORT",CMDMDE=CMDMDE, UNLOCKED,AUTOMATICINSERVICE;

Table 11-22 ED-E3 Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

  • FACILITY

Facility

  • TERMINAL

Terminal

  • OFF

Off

  • ALL

All

<CLKSRC>

Clock Source

  • INTERNAL

INTERNAL

  • LOOPBACK TIMING

LOOPBACK TIMING

  • SYNCE

SYNCE

  • ADAPTIVE

ADAPTIVE

<FMT>

(Optional) Digital signal frame format. Defaults to E1-MF. The parameter type is FRAME_FORMAT, which is the frame format for an E1 port.

  • AUTOPROV

AUTOPROV

  • CBIT

C-BIT line type applies to the DS3XM and DS3E cards.

  • DS2 FRAMED

DS2 FRAMED

  • E2 FRAMED

E2 FRAMED

  • E3-FRAME

E3-FRAME

  • E3-PLCP

E3-PLCP

  • FRAMENA

FRAMENA

  • G-751

G-751

  • G-832

G-832

  • M13

M13 line type applies to the DS3XM and DS3E cards.

  • M23

M23

  • SYNTRAN

SYNTRAN

<LINECDE>

(Optional) Line code. Defaults to HDB3. The parameter type is LINE_CODE (line code). (Applicable only for SDH platform).

  • B3ZS

Binary three-zero substitution.

  • B6ZS

B6ZS

  • JBZS

JBZS

  • ZBTSI

ZBTSI

<TACC>

(Optional) TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. TACC is an integer.

<TAPTYPE>

(Optional) TAP type. Defaults to DUAL. The parameter type is TAPTYPE, which is the test access point type.

  • DUAL

Dual FAD

  • SINGLE

Single FAD

<SFBER>

(Optional) Signal failure threshold. Defaults to 1E-4. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.

  • 1E-3

SFBER is 1E-3.

  • 1E-4

SFBER is 1E-4.

  • 1E-5

SFBER is 1E-5.

<SDBER>

(Optional) Signal degrade threshold. Defaults to 1E-7. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.

  • 1E-5

SDBER is 1E-5.

  • 1E-6

SDBER is 1E-6.

  • 1E-7

SDBER is 1E-7.

  • 1E-8

SDBER is 1E-8.

  • 1E-9

SDBER is 1E-9.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals.Defaults to 32. SOAK is an integer.

<NAME>

(Optional) NAME is a string. Defaults to NULL. Maximum length is 32 characters.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.26 ED-E4

(Cisco ONS 15454 SDH) The Edit E4 (ED-E4) command edits the attributes of an E4 facility. Currently this is only applicable to STM1E Ports 9 to 12 when they are in E4-FRAMED or E4-UNFRAMED mode.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ports

Security

Provisioning

Input Format

ED-E4:[<TID>]:<AID>:<CTAG>:::[SFBER=<SFBER>],[SDBER=<SDBER>],[SOAK=<SOAK>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-E4:CISCO1:FAC-6-1:114:::SFBER=1E-4,SDBER=1E-6,SOAK=10,NAME="E4 PORT",
CMDMDE=NORM:UNLOCKED,AUTOMATICINSERVICE;

Table 11-23 ED-E4 Command Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<SFBER>

(Optional) Signal failure threshold. Defaults to 1E-4. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.

  • 1E-3

SFBER is 1E-3.

  • 1E-4

SFBER is 1E-4.

  • 1E-5

SFBER is 1E-5.

<SDBER>

(Optional) Signal degrade threshold. Defaults to 1E-7. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.

  • 1E-5

SDBER is 1E-5.

  • 1E-6

SDBER is 1E-6.

  • 1E-7

SDBER is 1E-7.

  • 1E-8

SDBER is 1E-8.

  • 1E-9

SDBER is 1E-9.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals.Defaults to 32. SOAK is an integer.

<NAME>

(Optional) NAME is a string. Defaults to NULL. Maximum length is 32 characters.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.27 ED-EFM

(Cisco ONS 15454 SDH) The Edit Ethernet in the First Mile (ED-EFM) command edits the ethernet OAM parameters on the front end port of the fast (10/100 Mbps) ethernet card.

 
Usage Guidelines

  • The EFMSTATE parameter should be “enabled” for the facility by ED-FSTE to edit the EFM parameters.
  • You cannot enable or disable the remote loopback through the local interface on the remote OAM peer entity if any other type of loopback (facility/terminal) is already configured on the local interface.

Category

Ports

Security

Provisioning

Input Format

ED-EFM:[<TID>]:<AID>:<CTAG>:::[STATE=<STATE>],[MODE=<MODE>],[LFACTION=<LFACTION>],[SESSIONTIMER=<SESSIONTIMER>];

Input Example

ED-EFM::ETH-12-1-1:1:::MODE=PASSIVE,LFACTION=ERROR-BLOCK,DGACTION=ERROR-BLOCK,SESSIONTIMER=40;

 

Table 11-24 ED-EFM Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “ETH” section.

<STATE>

Indicates whether the EFM is enabled or disabled on the port.

  • ENABLE

Indicates the EFM is enabled on the port.

  • DISABLE

Indicates the EFM is disabled on the port.

<MODE>

Indicates the mode of the EFM port.

  • ACTIVE

The port is in the active state.

  • PASSIVE

The port is in the passive state.

<LFACTION>

Action to be taken for the failure of the link on the port.

  • RFIACTION-NONE

No action.

  • ERROR-BLOCK

Block the port.

<SESSIONTIMER>

Session expire timer for EFM (in seconds).

11.28 ED-ETH

(Cisco ONS 15454 SDH) The Edit Ethernet (ED-ETH) command edits the front-end port information of a 10/100/1000 Mbps Ethernet card.

 
Usage Guidelines

The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

SELECTIVEAUTO parameter is applicable only when EXPSPEED and EXPDUPLEX is not set to AUTO mode.


NoteThis command is available in Software Release 8.0.1 and later. It is not available in R8.0.0 and earlier.


Category

Ethernet

Security

Provisioning

Input Format

ED-ETH:[<TID>]:<AID>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>],[SELECTIVEAUTO=<SELECTIVEAUTO>],[EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOSTHRESHOLD>],[IPTOS=<IPTOSTHRESHOLD>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>],[LIENABLE=<LIENABLE>],[LITIMER=<LITIMER>][:<PST>[,<SST>]];

Input Example

ED-ETH:CISCO:FAC-1-1:123:::FLOW=FLOW,EXPDUPLEX=EXPDUPLEX,
SELECTIVEAUTO=SELECTIVEAUTO, EXPSPEED=EXPSPEED,
VLANCOS=VLANCOS,IPTOS=IPTOS,NAME="ETHPORT",CMDMDE=CMDMDE,
SOAK=32,LIENABLE=Y,LITIMER=200:IS,AINS;

Table 11-25 ED-ETH Command - Parameter Support

Input Parameters
Description

<AID>

Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “ETH” section.

<FACILITY>

Access identifier from the “FACILITY” section.

<FLOW

(Optional) Flow. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<EXPDUPLEX>

(Optional) Ethernet duplex mode. The parameter type is ETHER_DUPLEX, which is the duplex mode.

  • AUTO

Auto mode

  • FULL

Full mode

  • HALF

Half mode

<SELECTIVEAUTO>

(Optional) Selective auto-negotiation. The parameter is Y or N (enable or disable auto-negotiation) This indicates selective auto-negotiation of EXPSPEED and EXPDUPLEX only.

  • Y

Enable selective auto-negotiation.

  • N

Disable selective auto-negotiation.

<EXPSPEED>

(Optional) Ethernet speed. The parameter type is ETHER_SPEED, which is the Ethernet speed.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 10_MBPS

10 Megabits per second

  • 1_GBPS

1 Gigabit per second

  • 40_GBPS

40 Gigabit per second

  • AUTO

Auto

  • AUTO_FDX

Enable auto negotiation with full duplex.

<VLANCOS>

(Optional) Priority queing threshold based on VLAN class of service for incoming Ethernet packets. VLANCOS is an integer.

<IPTOS>

(Optional) Priority queing threshold based on IP type of service for incoming Ethernet packets. IPTOS is an integer.

<NAME>

(Optional) Name. NAME is a string.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

<SUPPRESS>

Pre-service alarm flag for data ports.

  • ON

Enable suppress.

  • OFF

Disable suppress. Default is Off.

<SOAK>

(Optional) OOS-AINS to IS transition soak time as measured in 15-minute intervals. SOAK is an integer.

<LIENABLE>

(Optional) Enable or Disable link integrity timer. Takes either Y or N. Value Y enables the LITIMER and value N disables LITIMER.

By default LITIMER is enabled.

Note The LIENABLE parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<LITIMER>

(Optional) Link integrity timer duration in the range between 200 ms and 10000 ms in multiples on 100 ms.

Note The LITIMER parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<PST>

(Optional) Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.29 ED-EQPT

(Cisco ONS 15454 SDH) The Edit Equipment (ED-EQPT) command edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this command is allowed only on the working AID. The ED-EQPT command also modifies a shelf role from NC to SC on an NE configured in multishelf mode.

 
Usage Guidelines

The PROTID parameter indicates the unique identifier of the protection group (the protect card). “NULL” is a special value of the PROTID parameter and indicates absence of a protection group. For the 1:1 protection type, RVRTV and RVTM parameters can be changed. For the 1:1 protection type, if the PROTID parameter is entered as “NULL”, the protection group is deleted, as shown in the following example:

ED-EQPT:[<TID>]:SLOT-2:<CTAG>:::PROTID=NULL;

For the 1:N protection type, if the PROTID is “NULL”, the AIDs in the list are removed from the protection group. If all the working cards are in the AID list, the protection group is deleted.

For example, if Slot 1, Slot 2, and Slot 4 were the only working cards in the protection group, the following command will remove Slot 4 from the protection group:

ED-EQPT:[<TID>]:SLOT-4:<CTAG>:::PROTID=NULL;

The protection group still has Slot 1 and Slot 2 as working cards.

The following command will remove all the other working cards in the preceding example and consequently delete the protection group itself:

ED-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>:::PROTID=NULL;

The ED-EQPT command can be successfully executed on an already provisioned card to add or remove a working card from a protection group. This command is not valid on a protect card. Only cards can be added to or removed from a protection group. Protection type is immutable and is determined at the time of creation of a protection group (while adding the first working card). After it is provisioned, the equipment type cannot be edited either.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

The following examples show how to add an existing card to a protection group using the ED-EQPT command:

  • 1:1 protection group:

ED-EQPT::SLOT-2:12:::PROTID=SLOT-1,RVRTV=Y,RVTM=9.0;

  • 1:N protection group:

ED-EQPT::SLOT-2:12:::PROTID=SLOT-3,PRTYPE=1-N,RVTM=6.5;

Error conditions for editing a 1:1 or 1:N protection group could be:

  • Editing the PRTYPE or PROTID (non-NULL value) parameters.
  • Editing RVRTV or RVTM when no protection group exists.
  • Editing RVRTV for 1:N protection.
  • Failed to remove, currently switched to protect.

The DS3i-N-12 card’s provisioning is based on the cross-connect type and the DS3i-N-1 card’s location. CARDMODE provisioning is allowed on the DS3i-N-12 and ML-Series cards as follows:

  • The DS3i-N-12 card in the lower speed I/O slot with the cross-connect card only allows the DS3I-VC32 CARDMODE. Other cases allow the CARDMODE to be DS3I-VC-4-16.
  • There is no card reboot if the CARDMODE is changed on the DS3i-N-12 card.
  • The DS3i-N-12 card can be upgraded or downgraded by changing the CARDMODE with the ED-EQPT command.

CMDMDE provisioning behaves as follows:

  • If the command mode (CMDMDE) is set to NORM during the creation of a 1:1 or 1:N protection group, all cards must be physically plugged in and in the service state (IS). If the cards are not physically plugged in and are not in ready state, the command is denied with an appropriate error message. CMDMDE=FRCD will override the default behavior and allow creation of protection group regardless of the physical presence and ready state of cards.
  • If the command mode is set to NORM during the removal of a card in a 1:1 or 1:N protection group, there must be no cross-connects (for example, services) present on the card. CMDMDE=FRCD will override the default behavior and allow deletion of protection group regardless of presence of cross-connects on the card.

On the FC_MR-4 card, the card mode cannot be changed to FCMR-LINERATE when the payload on any port is 1GFICON or 2GFICON. These payloads are allowed only in Distance Extension Card Mode.

Category

Equipment

Security

Provisioning

Input Format

Cisco ONS 15454 SDH

ED-EQPT[:<TID>]:<AID>:<CTAG>[:::PROTID=<PROTID>],[PRTYPE=<PRTYPE>],[RVRTV=<RVRTV>],[RVTM=<RVTM>],[CARDMODE=<CARDMODE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>],[PEERNAME=<PEERNAME>],[CMDMDE=<CMDMDE>],[RETIME=<RETIME>],[SHELFROLE=<SHELFROLE>],[NEWSHELFID=<NEWSHELFID>],[FRPROLE=<FRPROLE>],[FRPSTATE=<FRPSTATE>],[FRPHOLDOFFTIME=<FRPHOLDOFFTIME>],[ADMINCVLAN=<ADMINCVLAN>],[ADMINSVLAN=<ADMINSVLAN>],[CFMSTATE=<CFMSTATE>],[CCTIMER=<CCTIMER>],[PROTOPMODE=<PROTOPMODE>],[SWITCHWITHCRCALARM=<SWITCHWITHCRCALARM>],[CRCTHR=<CRCTHR>],[CRCPOLLINTRVL=<CRCPOLLINTRVL>],[CRCSOAKCNT=<CRCSOAKCNT>],[USB=<USB>][:<PST>[,<SST>]];

Input Example

Cisco ONS 15454 SDH

ED-EQPT::SLOT-15:a::CARDMODE=GEXP-L2ETH,SWITCHWITHCRCALARM=Y;

ED-EQPT::SLOT-15:a::CARDMODE=GEXP-L2ETH,CRCPOLLINTRVL=4;

 

Table 11-26 ED-EQPT Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “EQPT” section.

<CMDMDE>

The parameter type is command mode (CMDMDE). Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in IS-NR or OOS-AU,AINS service states.

  • FRCD

Force the system to override a state where the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that might make the command fail.

<CARDMODE>

Defines the card mode.

  • 10GLANWAN-LINE-SQUELCH

Changes the card mode from LAN to WAN.

  • DS1E1-DS1ONLY

DS1 mode on DS1E1 card.

  • DS1E1-E1ONLY

E1 mode on DS1E1 card.

  • DS1E1-E1MIXED

Hybrid/E1-retimed port usage profile.

  • DS1E1-DS1MIXED

Hybrid/DS1-retimed port usage profile.

  • DS3XM12-STS12

Indicates the DS3XM-12 card in the STS12 back plane rate mode.

  • DS3XM12-STS48

Indicates the DS3XM-12 card in the STS12 back plane rate mode.

  • DWDM-LINE

Line terminating mode.

  • DWDM-SECTION

Section terminating mode.

  • DWDM-TRANS-AIS

Transparent mode AIS.

  • DWDM-TRANS-SQUELCH

Transparent mode SQUELCH.

  • FCMR-DISTEXTN

FC-MR-4 card with Distance Extension support.

  • FCMR-LINERATE

FC-MR-4 card without Distance Extension support.

  • ML-GFP

ML1 series card in DOS FPGA using GFP framing type.

  • ML-HDLC

ML1 series card in DOS FPGA using HDLC framing type.

  • ML-IEEE-RPR

ML1 series card in DOS FPGA which supports Resilient Packet Ring (RPR).

  • MXPMR25G-FCGE

Fiber channel or GIGE mode for the MXP-MR-2.5G.

  • MXPMR10DME-FCGEISC

Fiber channel, GIGE, or ISC mode for the Cisco ONS 15454 MXP-MR-10DME, MXP-MR-10DMEX card series.

  • MXPMR10DME-FCGEISC-4GFC

1..4 facilities with fiber channel, GIGE, or ISC traffic mode and facility 5 with 4 Gbps fiber channel traffic mode for the Cisco ONS 15454 MXP-MR-10DME, MXP-MR-10DMEX card series.

  • MXPMR10DME-4GFC-FCGEISC

Facility 1 with 4 Gbps fiber channel traffic mode and 5..8 facilities with fiber channel, GIGE, or ISC traffic mode for the Cisco ONS 15454 MXP-MR-10DME, MXP-MR-10DMEX card series.

  • MXPMR10DME-4GFC

4 Gbps fiber channel traffic mode for the Cisco ONS 15454 MXP-MR-10DME, MXP-MR-10DMEX card series.

  • PSM-NORMAL

PSM working in classic configuration.

  • PSM-STANDALONE

PSM working in stand-alone mode.

  • AMPL-BST

Booster mode for amplifier cards: OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards.

  • AMPL-PRE

Pre-amplifier mode for amplifier cards: OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards.

  • 10GEXP-TXP

10GE-XP behaves as two separate transponders, where client 1 is associated to trunk 3 and client 2 is associated to trunk 4.

  • 10GEXP-L2ETH

10GE-XP behaves as an L2 Ethernet switch.

  • GEXP-10x1Gx2-MXP

GE-XP behaves as a double Muxponder having ten 1 Gbps client facilities with one trunk. The first 10 GIGE clients are associated to the first trunk (21), while GIGE facilities from 11 to 20 are associated to trunk 22.

  • GEXP-20x1G-MXP

GE-XP behaves as a single Muxponder having ten 1 Gbps client facilities with one trunk. Only the first 10 GIGE clients are associated to the first trunk (21) while the other facilities are unused.

  • GEXP-L2ETH

GE-XP behaves as an L2 Ethernet Switch.

  • CEMR-AUTO

Auto allocation of back-end channels for CE-MR-10 (Cisco ONS 15454 SONET only)

  • CEMR-MANUAL

Manual allocation of back-end channels for CE-MR-10 (Cisco ONS 15454 SONET only)

  • UNKNOWN

Unknown.

  • WXC80-BIDI

80-WXC-C working in bidirectional mode.

  • WXC80-DMX

80-WXC-C working as demultiplexer.

  • WXC80-MUX

80-WXC-C working as multiplexer.

  • 40G-MXP-MUXPONDER

40G-MXP-MUXPONDER working as multiplexer.

  • 40G-MXP-UNIDIR-REGEN

40G-MXP-UNIDIR-REGEN working as regenerator.

<FRPHOLDOFFTIME>

Indicates the hold off timer value. The protection does not start until the hold off time expires.

  • 100-MSEC

Indicates the hold off timer value as 100 milliseconds.

  • 1-MSEC

Indicates the hold off timer value as 1milisecond.

  • 200-MSEC

Indicates the hold off timer value as 200 milliseconds.

  • 2-MSEC

Indicates the hold off timer value as 2 milliseconds.

  • 500-MSEC

Indicates the hold off timer value as 500 milliseconds.

  • 50-MSEC

Indicates the hold off timer value as 50 milliseconds.

  • 5-MSEC

Indicates the hold off timer value as 50 milliseconds.

  • DISABLED

Indicates that the hold off timer is disabled.

<ADMINCVLAN>

Customer VLAN identifier for REP. ADMINCVLAN is a number between 1 and 4096. The value 0 is reserved to untagged VLAN.

<ADMINSVLAN

>

Service provider VLAN identifier for REP. ADMINSVLAN is a number between 1 and 4096. The value 0 is reserved to untagged VLAN.

<CFMSTATE>

Link Integrity status.

  • Y

Enabled

  • N

Disabled

<CCTIMER>

Indicates continuity check message timer.

  • ONE-MIN

1 minute.

  • ONE-SEC

1 second.

  • TEN-SEC

10 seconds.

<PROTOPMODE>

PROTOPMODE

<FRPROLE>

Indicates the fast ring protection enable mode for GE-XP/10GE-XP units involved in a protection scheme.

  • MASTER

Role is of card master of the ring.

  • SLAVE

Role is of card slave of the ring.

<FRPSTATE>

Indicates the fast ring protection enable state.

  • DISABLED

Disabled protection

  • ENABLED

Enabled protection

  • FORCED

Forced protection

<NEWSHELFID>

(Optional) New shelf identifier is used to change the value of the shelf identifier for the addressed shelf. The value must be different by one and can be in the range from two to eight. This field can only be changed if (in the same command) the SHELFROLE is equal to SC. Integer.

<PEERID>

The regeneration peer slot from the “EQPT” section.

<PROTID>

(Optional) Protection group name. PROTID is a string.

<REGENNAME>

The name of a regeneration group. REGENNAME is a string.

<RETIME>

(Optional) Indicates the RETIME function for all the facilities on this card. The parameter type is ON_OFF (disable or enable an attribute). (Supported on the DS1/E1-56 card for the Cisco ONS 15454 SDH platform).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Defaults to N, non-revertive.

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<SWITCHWITHCRCALARM>

Switch the GZ card with CRC Alarms

<CRCTHR>

CRC threshold values beyond which alarms are raised. The available threshold values are 10E-2, 10E-3, and 10E-4.

<CRCPOLLINTRVL>

Interval of time after which the polling starts.

<CRCSOAKCNT>

Number of poll cycles during which defect is integrated. The value ranges from 3 to 10.

<USB>

Identifies the USB port where a passive unit is connected.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SHELFROLE>

The role of the shelf in the context of the node. When it is omitted it defaults to SC. The parameter is SHELF_ROLE.

<SST>

(Optional) Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.30 ED-FAC

(Cisco ONS 15454 SDH) The Edit Facility (ED-FAC) command edits the payload (or signal) type of a facility.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ports

Security

Provisioning

Input Format

ED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-FAC:CISCO:FAC-3-9:2222:::PAYLOAD=E4-FRAMED,
CMDMDE=NORM:UNLOCKED,AUTOMATICINSERVICE;


NoteThe ED-FAC command is supported only on the STM1E-12 card on the Cisco ONS 15454 SDH.


Table 11-27 ED-FAC Command - Parameter Support

Input Parameters
Description

<SRC>

Source access identifier from the “FACILITY” section.

<PAYLOAD>

(Optional) Payload. The parameter type is PAYLOAD, which identifies payload type.

  • E4 Framed

E4 Framed facility

  • E4 Unframed

E4 Unframed facility

  • STM 1E

STM 1E facility

  • E3

E3 facility

  • T3

T3 facility

  • OC3

OC3 facility

  • OC12

OC12 facility

  • OC48

OC48 facility

<CMDMDE>

Command mode. Defaults to NORM. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state in which the command would normally be denied.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

Primary state. Defaults to Unlocked. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

Secondary state. Defaults to AutomaticInService. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Maintenance

Maintenance mode

11.31 ED-FFP-<MOD2DWDMPAYLOAD>

(Cisco ONS 15454 SDH, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Edit Facility Protection Group for 10GFC, 10GIGE, 40GIGE, 100GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, 4GFC, 4GFICON, 8GFC, D1VIDEO, DV6000, DVBASI, ETRCLO, FSTE, GIGE, HDTV, ISC1, OTU3, OTU1, OTU2, OTU4, ISC3STP1G, or ISC3STP2G (ED-FFP-<MOD2DWDMPAYLOAD>) command edits the operating parameters for a dense wavelength division multiplexing (DWDM) client facility.

 
Usage Guidelines

  • Y-cable with bidirectional protection is applicable only for ISC3STP1G and ISC3STP2G payloads on the AR-MXP, AR-XP, and AR-XPE cards.
  • Y-cable with unidirectional protection is applicable only for payloads other than ISC3STP1G and ISC3STP2G on the AR-MXP, AR-XP, and AR-XPE cards.
  • The command does not support 3GVIDEO, SDSDI, HDSDI, and AUTO payloads on AR-MXP, AR-XP, and AR-XPE cards.

Category

DWDM

Security

Provisioning

Input Format

ED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];

Input Example

ED-FFP-OTU1:CISCO:VFAC-1-1-1:100:::PROTID=DC-METRO,RVRTV=N,RVTM=1.0,PSDIRN=BI;

 

Table 11-28 ED-FFP-<MOD2DWDMPAYLOAD> Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section. The AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID.

<PROTAID>

(Optional) The protection group identifier (protection group name). Defaults to the protecting port AID of the protection group. PROTAID can have a maximum length of 32 characters. PROTAID is a string.

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection-switching. Null defaults to N. Only applies to SNCP. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. RVTM is not allowed to be set while RVRTV is N. Only applies to SNCP. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 9.5

Revertive time is 0.5 to 9.5 minutes.

<PSDIRN>

(Optional) Protection switch operation. Identifies the switching mode. Defaults to UNI. The parameter type is UNI_BI (unidirectional or bidirectional switch operations).

Note The MXP_2.5G_10G and TXP_MR_10G cards do not support bidirectional switching.

  • BI

Bidirectional protection switching

  • UNI

Unidirectional protection switching

11.32 ED-FFP-<STM_TYPE>

(Cisco ONS 15454 SDH) The Edit Facility Protection Group for STM1, STM4, STM16, or STM64 (ED-FFP-<STM_TYPE) command edits the optical facility protection. See Table 27-1 for supported modifiers by platform.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.


NoteThis command can be used on both protecting and working AIDs.


Category

Protection

Security

Provisioning

Input Format

ED-FFP-<STM_TYPE>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[:];

Input Example

ED-FFP-STM1:PETALUMA:FAC-1-1:1:::PROTID=PROT_NAME,RVRTV=Y,RVTM=1.0,
PSDIRN=BI;

 

Table 11-29 ED-FFP-<STM_TYPE Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<PROTAID>

(Optional) The protection group identifier (protection group name). PROTAID can have a maximum length of 32 characters. PROTAID is a string.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<PSDIRN>

(Optional) Protection switch operation. Indicates the switch mode. The parameter type is TRANS_MODE, which is the G1000 transponder mode.

  • BI

Bidirectional

  • NONE

Not in transponder mode

  • UNI

Unidirectional

<VRGRDTM>

(Optional) Verification guard timer. Only applicable to optimized 1+1. The parameter type is VERIFICATION_GUARD_TIMER, which is the optimized 1+1 verification guard timer.

  • 0.5

500 ms

  • 1.0

1 second

<DTGRDTM>

(Optional) Detection guard timer. Only applicable to optimized 1+1. The parameter type is DETECTION _GUARD_TIMER, which is the optimized 1+1 detection guard timer.

  • 0.0

0 seconds

  • 0.05

50 ms

  • 0.1

100 ms

  • 0.5

500 ms

  • 1.0 to 5.0

1 second to 5 seconds

<RCGRDTM>

(Optional) Recovery guard timer. Only applicable to optimized 1+1. The parameter type is RECOVERY_GUARD_TIMER, which is the optimized 1+1 recovery guard timer.

  • 0.0

0 seconds

  • 0.05

50 ms

  • 0.1

100 ms

  • 0.5

500 ms

  • 1.0 to 10.0

1 second to 10 seconds

11.33 ED-FFP-OCH

(Cisco ONS 15454 SDH) The Edit Facility Protection Group Optical Channel (ED-FFP-OCH) command changes the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G or TXPP_MR_2.5G card.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

DWDM

Security

Provisioning

Input Format

ED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];

Input Example

ED-FFP-OCH:VA454-22:CHAN-2-2:100:::PROTID=“FIXED PROTECTION”,RVRTV=N,
RVTM=1.0,PSDIRN=BI;

Table 11-30 ED-FPP-OCH Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “CHANNEL” section.

<PROTAID>

(Optional) The protection group identifier (protection group name). PROTAID is a string.

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<PSDIRN>

(Optional) Protection switch operation. The parameter type is TRANS_MODE, which is the G1000 transponder mode.

  • BI

Bidirectional

  • NONE

Not in transponder mode

  • UNI

Unidirectional

11.34 ED-FFP-OTS

(Cisco ONS 15454 SDH) The Edit Facility Protection Group OTS (ED-FFP-OTS) command changes provisioning for the Y-cable or splitter protection group on the OTU2-XP card

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

DWDM

Security

Provisioning

Input Format

ED-FFP-OTS:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];

Input Example

ED-FFP-OTS:VA454-22:CHAN-2-2:100:::PROTID=“FIXED PROTECTION”,RVRTV=N,
RVTM=1.0,PSDIRN=BI;

Table 11-31 Parameter Support

Parameter
Description

<AID>

Access identifier from the “CHANNEL” section.

<PROTAID>

The protection group identifier (protection group name). PROTAID is a string.

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<PSDIRN>

(Optional) Protection switch operation. The parameter type is TRANS_MODE, which is the G1000 transponder mode.

  • BI

Bidirectional

  • NONE

Not in transponder mode

  • UNI

Unidirectional

11.35 ED-FOG

(Cisco ONS 15454 SDH) The Edit Fan-Out-Group (ED-FOG) command adds and deletes the members connecting to the CPT 50 panel and applied on the carrier packet transport (CPT) system.

 
Usage Guidelines

The interfaces that can be attached should be valid for the FOG. At least one interface must be always attached to the FOG.

Category

Equipment

Security

Provisioning

Input Format

ED-FOG[:<TID>]:<AID>:<CTAG>[:::ATTACH=<ATTACH>],[DETACH=<DETACH>],[QUEUEMODE=<QUEUEMODE>],[PBNAME=<PBNAME>];

Input Examples

ED-FOG::FOG-1-36:1:::ATTACH=FAC-2-2-1;

Input Parameters

<AID>

Access identifier from the “EQPT” section.

<ATTACH>

AID of the fabric and line card ports used as the Fan-out members. This is the AID of the interface to be attached to the FOG.

<DETACH>

AID of the fabric and line card ports used as the Fan-out members. This is the AID of the interface to be detached from the FOG.

<QUEUEMODE>

QUEUEMODE

  • NOPRI

NOPRI

  • STRICT

STRICT

<PBNAME>

PBNAME

11.36 ED-FSTE

(Cisco ONS 15454 SDH, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Edit Fast Ethernet (ED-FSTE) command edits the front end port information of the Fast Ethernet (10/100 Mbps) card.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

SELECTIVEAUTO parameter is applicable only when EXPSPEED and EXPDUPLEX is not set to AUTO mode.

Squelch can either be enabled or set to transparent on FE.


NoteFor the ML-100T-8 card, only the NAME parameter can be set.


Category

Ports

Security

Provisioning

Input Format

ED-FSTE:[<TID>]:<SRC>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>],[EXPSPEED=<EXPSPEED>],[SELECTIVEAUTO=<SELECTIVEAUTO>],[VLANCOS=<VLANCOSTHRESHOLD>],[IPTOS=<IPTOSTHRESHOLD>],[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>],[LIENABLE=<LIENABLE>],[LITIMER=<LITIMER>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[CIR=<CIR>],[CBS=<CBS>],[EBS=<EBS>],[OSC=<OSC>],[AUTONEG=<AUTONEG>],[MTU=<MTU>],[SQUELCHMODE=<SQUELCH>]:[<PST>[,<SST>]];

Input Example

ED-FSTE:CISCO:FAC-1-1:123:::FLOW=Y,EXPDUPLEX=HALF,EXPSPEED=10_MBPS,
SELECTIVEAUTO=Y,VLANCOS=2,IPTOS=4,NAME="FSTEPORT",CMDMDE=FRCD,
SUPPRESS=Y,SOAK=32,LIENABLE=Y,LITIMER=200:IS,AINS;

Table 11-32 ED-FSTE Command- Parameter Support

Input Parameter s
Description

<AID>

Access identifier from the “FACILITY” section. The AR-MXP, AR-XP, and AR-XPE cards use the VFAC Access Identifier.

<FLOW>

(Optional) Flow control. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<EXPDUPLEX>

(Optional) Ethernet duplex mode. The parameter type is ETHER_DUPLEX, which is the duplex mode.

  • AUTO

Auto mode

  • FULL

Full mode

  • HALF

Half mode

<EXPSPEED>

(Optional) Ethernet speed. The parameter type is ETHER_SPEED, which is the Ethernet speed.

  • 100_MBPS

100 Megabits per second

  • 10_GBPS

10 Gigabits per second

  • 40_GBPS

40 Gigabits per second

  • AUTO_FDX

Enable auto negotiation with full duplex.

<SELECTIVEAUTO>

Auto-negotiation.

  • Y

Enable selective auto-negotiation.

  • N

Disable selective auto-negotiation.

<VLANCOS>

(Optional) Priority queuing threshold based on VLAN class of service of incoming Ethernet packets. Default value is 1175. VLANCOS is an integer.

<IPTOS>

(Optional) Priority queuing threshold based on IP type of service of incoming Ethernet packets. Default value is 368. IPTOS is an integer.

<NAME>

(Optional) Name. NAME is a string.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<SUPPRESS>

Pre-service alarm flag for data ports.

  • ON

Enable suppress.

  • OFF

Disable suppress. Default is Off.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<LIENABLE>

(Optional) Enable or Disable link integrity timer. Takes either Y or N. Value Y enables the LITIMER and value N disables LITIMER.

By default LITIMER is enabled.

Note The LIENABLE parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<LITIMER>

(Optional) Link integrity timer duration in the range between 200 ms and 10000 ms in multiples on 100 ms.

Note The LITIMER parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<FREQ>

(Optional) The parameter type is OPTICAL_WLEN, which indicates the optical wavelength.

  • 1310

Wavelength 1310.

  • 1529.16

Wavelength 1529.16

  • 1562.23

Wavelength 1562.23

  • 1562.64

Wavelength 1562.64

  • 1563.05

Wavelength 1563.05

  • 1563.45

Wavelength 1563.45

  • 1563.86

Wavelength 1563.86

  • 1564.27

Wavelength 1564.27

  • 1564.68

Wavelength 1564.68

  • 1565.09

Wavelength 1565.09

  • 1565.50

Wavelength 1565.50

  • 1565.90

Wavelength 1565.90

  • 1566.31

Wavelength 1566.31

  • 1566.72

Wavelength 1566.72

<LOSSB>

(Optional) The parameter type is REACH, which indicates the reach values.

  • 100GBASE-LR4

100GBASE-LR4

  • 100GBASE-SR10

100GBASE-SR10

  • 40GBASE-FR

40GBASE-FR

  • 40GBASE-LR4

40GBASE-LR4

  • 40GBASE-SR4

Reach supported on 40GIGE payload on CFP-LC card.

  • 4I1-9D1F

4I1-9D1F

  • C4S1-2D1

C4S1-2D1

  • FE-BX

FE-BX

  • FX

FX

  • GE-BX

GE-BX

  • GE-EX

GE-EX

  • LX-10

LX-10

  • TEN-GE-LRM

TEN-GE-LRM

  • TEN-GE-ZR

TEN-GE-ZR

  • VSR2000-3R2

VSR2000-3R2

  • AUTOPROV

Auto provisioning

  • CWDM

Coarse wavelength division multiplexing (CWDM)

  • CWDM-40KM

CWDM 40 kilometers.

  • CX1

Reach CX1

  • LR

Reach LR

  • LR-2

Reach LR-2

  • LX

Reach LX

  • P1I1-2D1

Long haul 10G Ethernet with 1310 nm wavelength

  • P1L1-1D2

Longhaul 2.5G Ethernet with 1550 nm wavelength

  • P1L1-2D2

Long haul 10G Ethernet with 1550 nm wavelength

  • P1S1-1D1

Shorthaul 2.5G Ethernet with 1310 nm wavelength

  • P1S1-2D1

Short haul 10G Ethernet in 1310 nm wavelength

  • SC

Reach SC

  • SR

Reach SR

  • TEN-GE-ER

10 GE extended range

  • TEN-GE-LR

10 GE long range

  • TEN-GE-SR

10 GE short range

  • ULH

Reach ULH

  • VSR

Reach VSR

<CIR>

Ingress committed information rate. This is a value between 0.0 and 100.0. Default value is 100.0.

<CBS>

Ingress committed burst bucket size.

  • 4K

4 Kbit bucket size

  • 8K

8 Kbit bucket size

  • 16K

16 Kbit bucket size

  • 32K

32 Kbit bucket size

  • 64K

64 Kbit bucket size

  • 128K

128 Kbit bucket size

  • 256K

256 Kbit bucket size

  • 512K

512 Kbit bucket size

  • 1M

1 Mbit bucket size

  • 2M

2 Mbit bucket size

  • 4M

4 Mbit bucket size

  • 8M

8 Mbit bucket size

  • 16M

16 Mbit bucket size

<EBS>

Ingress excess burst bucket size.

<OSC>

To enable or disable the OSC on the port.

Note The OSC parameter is supported only on 15454-M2 and 15454-M6.

<AUTONEG>

Automatic negotiation. Defaults to Y. The parameter type is ON_OFF, which disables or enables an attribute.

<MTU>

(Optional) Maximum transport unit. The parameter type is MTU_TYPE, which indicates the maximum transport unit used by an Ethernet card. Defaults to 9600.

<SQUELCHMODE>

Shuts down the far-end laser in response to certain defects

  • NONE

Transparent

  • SQUELCH

Squelch is enabled

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AINS

Automatic in service

  • DSBLD

Disabled

  • LPBK

Loopback

  • MEA

Mismatch of equipment and attributes

  • MT

Maintenance mode

  • OOG

Out of group

  • SWDL

Software downloading

  • UAS

Unassigned

  • UEQ

Unequipped

11.37 ED-FTPSERVER

(Cisco ONS 15454 SDH) The Edit FTP Server (ED-FTPSERVER) command edits FTP server entries.

 
Usage Guidelines

This command is used to edit only the ENABLE and TIMER parameters.

Category

ENE

Security

Superuser

Input Format

ED-FTPSERVER:[<TID>]::<CTAG>:::IPADDR=<IPADDR>,[ENABLE=<ENABLE>],
[TIMER=<TIMER>];

Input Examples

1. ED-FTPSERVER:::A:::IPADDR=10.20.30.40,ENABLE=Y,TIMER=30;

2. ED-FTPSERVER:TID::CTAG:::IPADDR=“[3ffe:0501:0008:0000:0260:97ff:fe40:efab]”,ENABLE=Y,
TIMER=45;

 

Table 11-33 ED-FTPSERVER- Parameter Support

Input Parameters
Description

<IPADDR>

Specifies the IP address of the FTP Server.

<ENABLE>

Specifies the enable/disable option of the FTP Server. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<TIMER>

(Optional) Specifies the timeout value of the FTP server in minutes. Timer is an integer that can be set between 0 and 60 minutes.

11.38 ED-G1000

(Cisco ONS 15454 SDH) The Edit G1000 (ED-G1000) command edits the attributes related to a G1000 port.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ports

Security

Provisioning

Input Format

ED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>],
[LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[LIENABLE=<LIENABLE>],
[LITIMER=<LITIMER>]:[<PST>[,<SST>]];

Input Example

ED-G1000:CISCO:FAC-1-1:CTAG:::MFS=1548,FLOW=Y,LOWMRK=20,HIWMRK=492,
AUTONEG=Y,NAME="G1000 PORT",CMDMDE=FRCD,SOAK=32,LIENABLE=Y
LITIMER=300:UNLOCKED,DSBLD;

 

Table 11-34 ED-G1000 Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<MFS>

(Optional) Maximum frame size. The parameter type is MFS_TYPE, which is the maximum frame size used by an Ethernet card.

  • 1548

Normal frame size

  • JUMBO

Jumbo frame size

<FLOW>

(Optional) Flow control. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<LOWMRK>

(Optional) Low watermark value. LOWMRK is an integer. Defaults to 25.

<HIWMRK>

(Optional) High watermark value. HIWMRK is an integer. Defaults to 485.

<AUTONEG>

(Optional) Automatic negotiation. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<NAME>

(Optional) Name. NAME is a string.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<LIENABLE>

(Optional) Enable or Disable link integrity timer. Takes either Y or N. Value Y enables the LITIMER and value N disables LITIMER.

By default LITIMER is enabled.

Note The LIENABLE parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<LITIMER>

(Optional) Link integrity timer duration in the range between 200 ms and 10000 ms in multiples on 100 ms.

Note The LITIMER parameter is supported on only CE-1000-4 and CE-1000T-8 cards on the 15454.

<ENCAP>

Specifies the mapping mode on the port provisioned. Parameter Type is ENCAP.

  • CBR

CBR mapping mode.

  • GFP

GFP mapping mode.

  • GMP

GMP mapping mode is supported only on 8GFC on 10x10G-LC card.

  • TRP

Transparent mapping mode.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.39 ED-GFP

(Cisco ONS 15454 SDH) The Edit Generic Framing Protocol (ED-GFP) command edits GFP parameters on FC_MR-4 and CE-1000-4 cards

 
Usage Guidelines

On the FC_MR-4 card, the parameters AUTOTHGFPBUF, GFPBUF, and FILTER can be edited only if distance extension is enabled (set to B2B).

Category

Ports

Security

Provisioning

Input Format

ED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],
[GFPBUF=<GFPBUF>],[FILTER=<FILTER>];

Input Example

ED-GFP:CISCO:VFAC-1-0:123:::FCS=N,AUTOTHGFPBUF=Y,GFPBUF=16,FILTER=EGRESS;

Table 11-35 ED-GFP Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “FACILITY” section.

<FCS>

(Optional) Payload frame check sequence. The parameter type is FCS (frame check sequence).

  • FCS-16

Frame check sequencing using 16 bits.

  • FCS-32

Frame check sequencing using 32 bits.

  • NONE

No frame check sequence.

<AUTOTHGFPBUF>

(Optional) Autothreshold GFP Buffer. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<GFPBUF>

(Optional) GFP buffer size. GFPBUF is an integer.

<FILTER>

(Optional) Parameter type is GFP_FILTER, which provides the filter feature in GFP.

  • INGRESS

Active filter feature on the Ingress port.

  • NONE

Turn off filter feature.

11.40 ED-HDLC

(Cisco ONS 15454 SDH) The Edit High-Level Data Link Control (ED-HDLC) command edits HDLC-related attributes for HDLC-encapsulated payloads.

 
Usage Guidelines

On the FC_MR-4 card, the parameters AUTOTHGFPBUF, GFPBUF, and FILTER can be edited only if distance extension is enabled (set to B2B).

On POS ports of CE-MR-10 card, FCS cannot be set to NONE when the encapsulation is set to GFP.

Category

Ports

Security

Provisioning

Input Format

ED-HDLC:[<TID>]:<SRC>:<CTAG>[:::FCS=<FCS>][CRC=<CRC>];

Input Example

ED-HDLC:PETALUMA:VFAC-1-1-PORT:CTAG:::FCS=FCS-16;

Table 11-36 ED-HDLC Command - Parameter Support

Input Parameters
Description

<SRC>

Access identifier from the “FACILITY” section.

<FCS>

Payload frame check sequence. The parameter type is FCS (frame check sequence).

  • FCS-16

Frame check sequence using 16 bits

  • FCS-32

Frame check sequence using 32 bits

  • NONE

No frame check sequence

<CRC>

Cyclic Redundancy Check.

Note CRC is applicable only to ADM10G card.

  • CRC-16

Cyclic Redundancy Check using 16 bits.

  • CRC-32

Cyclic Redundancy Check using 32 bits.

11.41 ED-L2-ETH

(Cisco ONS 15454 SDH) The Edit layer 2 Ethernet (ED-L2-ETH) command edits the layer 2 port information of GE-XP and 10GE-XP Ethernet cards.

 
Usage Guidelines

The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

Ethernet

Security

Provisioning

Input Format

ED-L2-ETH[:<TID>]:<AID>:<CTAG>[:::NIMODE=<NIMODE>],[MACLEARNING=<MACLEARNING>],[INGRESSCOS=<INGRESSCOS>],[ETHERCETYPE=<ETHER_CE_TYPE>],[ETHERSTYPE=<ETHER_S_TYPE>],[ALWMACADDR=<ALW_MAC_ADDR>],[INHMACADDR=<INH_MAC_ADDR>],[BPDU=<BPDU>],[BRIDGESTATE=<BRIDGE_STATE>],[QNQMODE=<QNQMODE>],[TRNSPSVLAN=<TRNSP_SVLAN>],[NAME=<NAME>],[IGMPROUTER=<IGMPROUTER>],[AISACTION=<AISACTION>],[PROTACTION=<PROTACTION>],[CMDMDE=<CMDMD>],[IGMPONCVLAN=<IGMPONCVLAN>],[IGMPCVLAN=<IGMPCVLAN>],[DLF=<DLF>],[DLFTHRES=<DLFTHRES>],[MCAST=<MCAST>],[MCASTTHRES=<MCASTTHRES>],[BCAST=<BCAST>],[BCASTTHRES=<BCASTTHRES>],[CLRCRCALM=<CLRCRCALM>][:];

Input Example

"ETH-2-21-1::NIMODE=NNI,MACLEARNING=N,INGRESSCOS=0,ETHERCETYPE=8100,ETHERSTYPE=8100,BPDU=N,BRIDGESTATE=FORWARDING,ACTBRIDGESTATE=UNKNOWN,QNQMODE=SELECTIVE,IGMPROUTER=NONE,AISACTION=AIS-NONE,PROTACTION=PROT-SQUELCH,IGMPONCVLAN=N,DLF=N,DLFTHRES=0,MCAST=N,MCASTTHRES=0,BCAST=N,BCASTTHRES=0,CLRCRCALM=N:"

"ETH-2-22-1::NIMODE=NNI,MACLEARNING=N,INGRESSCOS=0,ETHERCETYPE=8100,ETHERSTYPE=8100,BPDU=N,BRIDGESTATE=FORWARDING,ACTBRIDGESTATE=UNKNOWN,QNQMODE=SELECTIVE,IGMPROUTER=NONE,AISACTION=AIS-NONE,PROTACTION=PROT-SQUELCH,IGMPONCVLAN=N,DLF=N,DLFTHRES=0,MCAST=N,MCASTTHRES=0,BCAST=N,BCASTTHRES=0,CLRCRCALM=Y:"

Table 11-37 ED-L2-ETH Command - Parameter Support

Input Parameters
Description

<AID>

Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “ETH” section.

<NIMODE>

Identifies the Ethernet Network Interface Mode.

  • NNI

(Default) Network-Network Interface Mode

  • UNI

User-Network Interface Mode

<MACLEARNING>

MAC address learning mode. This activates the MAC address learning on the interface to avoid packet broadcasting.

  • Y

Enables MAC learning

  • N

Disable MAC learning

<INGRESSCOS>

Identifies the COS value set in the S-VLAN tag.

  • 0 to 7

Set a Cos value

  • DSCP

The COS is set according to DSCP to COS mapping table.

  • TRUST

Use the Customer COS

  • VLAN

The COS will be provisioned on CVLAN basis (QinQ selective mode)

<ETHERCETYPE>

Identifies a customer foreseen Ethernet type. If the customer uses a non-standard Ethernet type, the incoming packets will be accepted only if the CE-VLAN Ethernet type matches this parameter.

<ETHERSTYPE>

Identifies a customer foreseen Ethernet type. If the customer uses a non-standard Ethernet type, the incoming packets will be accepted only if the CE-VLAN Ethernet type matches this parameter.

<ALWMACADDR>

Identifies the allowed MAC addresses filtered out by the L2 Ethernet port. Every single MAC address is in the format of aa-bb-cc-dd-ee-ff, where every digit is in a hexadecimal form.

<INHMACADDR>

Identifies the inhibited MAC addresses filtered out by the L2 Ethernet port. Every single MAC address is in the format of aa-bb-cc-dd-ee-ff, where every digit is in a hexadecimal form.

<BPDU>

BPDU (Bridge Protocol Data Unit) management mode; Drop/Passthrough BPDU tagged packets.

  • Y

Enables the BPDU tag.

  • N

Disables the BPDU tag.

<BRIDGESTATE>

Defines if the traffic is blocked on the port.

  • Unknown

Unknown state

  • Disabled

Disabled state

  • Blocking

Blocking state

  • Listening

Listening state

  • Learning

Learning state

  • Forwarding

Forwarding state

  • Broken

Broken state

<QNQMODE>

This is used to represent the QinQ mode operations.

  • Selective

The S-VLAN tag is added only on specified CE-VLANs. The other packets are dropped.

  • Transparent

The S-VLAN tag is always performed where all packets having the S-VLAN-ID identified by TRNSPSVLAN parameter are allowed.

<TRNSPSVLAN>

VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs.

<NAME>

(Optional) Name. NAME is a string.

<IGMPROUTER>

IGMP M Router port. Indicates the type of connection between this port and the IGMP M Router.

  • STATIC

A static connection is present between this port and the IGMP M Router

  • NONE

No connection is present

<AISACTION>

VLAN-AIS Action. Indicates what action take place on port when VLAN-AIS alarm is raisedValues

  • AIS-SQUELCH

The port is squelched

  • AIS-NONE

No action after VLAN-AIS

<PROTACTION>

Indicates the action that takes place on the standby port in the protection unit when a ONEPLUSONEL2 protection is activated.

  • PROT-SQUELCH

The port is squelched.

  • PROT-NONE

Ethernet traffic is blocked.

<IGMPCVLAN>

Indicates the customer VLAN value for IGMP on CVLAN.

<IGMPONCVLAN>

Indicates IGMP on customer VLAN.

<DLF>

To enable or disable storm control on DLFPC packet.

<DLFTHRES>

Indicates the DLFPC packet threshold value for storm control.

<MCAST>

To enable or disable the storm control on multicast packet.

<MCASTTHRES>

Indicates the multicast packet threshold value for storm control.

<BCAST>

To enable or disable the storm control on broadcast packet.

<BCASTTHRES>

Indicates the broadcast packet threshold value for storm control.

<CLRCRCALM>

Clears the DATA-CRC alarm.

11.42 ED-LM-EFM

(Cisco ONS 15454 SDH) The Edit Link Monitoring Ethernet in the First Mile (ED-LM-EFM) command edits the Ethernet in the First Mile (EFM) link monitoring parameters and the action associated with each of the parameters.

 
Usage Guidelines

  • This command is applicable only to GE_XP and 10GE_XP cards.
  • The card should be in Layer2 over DMDM mode.

Category

Ports

Security

Provisioning

Input Format

ED-LM-EFM:[<TID>]:<AID>:<CTAG>:::LMPARAM=<LMPARAM>,[LOWTH=<LOWTH>],[HIGHTH=<HIGHTH>],[ACTION=<ACTION>],[WINDOW=<WINDOW>];

Input Example

ED-LM-EFM::ETH-12-1-1:1:::LMPARAM=ERR-FRAME,LOWTH=20,HIGHTH=30,ACTION=DISABLE-PORT,WINDOW=40;

 

Table 11-38 ED-EFM Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “ETH” section.

<LMPARAM>

Name of the link monitoring parameter.

  • ERR-FRAME

Error frames.

  • ERR-FRAME-PRD

Error frame period.

  • ERR-FRAME-SEC

Error frames second.

<LOWTH>

The lowest value of the link monitoring parameter. It is an integer.

<HIGHTH>

The highest value of the link monitoring parameter. It is an integer.

<ACTION>

Action to be taken when the link monitoring parameter crosses the HIGH value, which is set by the user. The value can be NONE or DISABLED.

<WINDOW>

This indicates the window associated with each of the link monitoring parameter (number of packets, number of frames or the timer). It is an integer.

11.43 ED-LMP

(Cisco ONS 15454 SDH) The Edit Link Management Protocol (ED-LMP) command edits the global LMP protocol attributes.

 
Usage Guidelines

This command is only available on platforms which support the LMP protocol.

Category

LMP

Security

Provisioning

Input Format

ED-LMP:[<TID>]::<CTAG>:::[ENABLED=<ENABLED>],[WDMEXT=<WDM>], [ROLE=<ROLE>], [LMPNODEID-<NODEID>][:];

Input Example

ED-LMP:PETALUMA::704:::ENABLED=Y,WDMEXT=Y,ROLE=PEER,
LMPNODEID=198.133.219.25;

Table 11-39 ED-LMP Command - Parameter Support

Input Parameters
Description

<ENABLED>

LMP Protocol Status.

  • Y

The protocol is enabled.

  • N

The protocol is disabled.

<WDM>

Determines if the LMP WDM extensions are in effect.

  • Y

The LMP WDM extensions are in effect.

  • N

The LMP WDM extensions are not in effect.

<ROLE>

The role the LMP protocol is configured to play.

  • OLS

The LMP protocol is configured to respond as an Optical Line System.

  • PEER

The LMP protocol is configured to respond as a peer node.

<NODEID>

LMP Node ID. NODEID is a stable IP address that is always reachable if there is any connectivity to it. The default LMP node ID value is the IP address of the node.

11.44 ED-LMP-CTRL

(Cisco ONS 15454 SDH) The Edit Link Management Protocol Control Channel (ED-LMP-CTRL) command edits the LMP control channels.

 
Usage Guidelines

This command is only available on nodes where the LMP protocol is available and has been enabled.

Category

LMP

Security

Provisioning

Input Format

ED-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],[REMOTEIP=<REMOTEIP>],[HELLO=<HELLO>],
[HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>],
[DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>];

Input Example

ED-LMP-CTRL:PETALUMA:CTRL-123:704:::LOCALPORT=FAC-1-1-1,
REMOTENE=15.15.15.115,REMOTEIP=126.0.0.1,HELLO=500,HELLOMIN=300,
HELLOMAX=5000,DEAD=12000,DEADMIN=2000,DEADMAX=20000:OOS,DSBLD;

Table 11-40 ED-LMP-CTRL Command - Parameter Support

Input Parameters
Description

<SRC>

The LMP control channel AID values

  • CTRL-ALL

Specifies all the control channels.

  • CTRL-{1-4}

Specifies an individual control channel.

<LOCALPORT>

Local port is the pathway that the LMP control channel will use to send and receive messages.

<REMOTENE>

Remote IP address used by the far-end LMP control channel.

<REMOTEIP>

Remote IP address with which the LMP control channel sends and receives messages.

<HELLO>

The time interval in which the LMP protocol sends HELLO messages.

<HELLOMIN>

Minimum hello time the LMP control channels can send out HELLO messages to the remote node.

<HELLOMAX>

The maximum amount of time the LMP control channel can wait between HELLO messages.

<DEAD>

Time interval an LMP control channel will wait for a HELLO message from the remote side before listing the control channel as down.

<DEADMIN>

The minimum amount of time that an LMP control channel can wait before listing the control channel status as down.

<DEADMAX>

The maximum amount of time that the LMP control channel can wait before listing the control channel as down.

<PST>

Primary State. This parameter indicates the current overall service condition of an entity.

  • IS

In service

  • OOS

Out of service

<SST>

Secondary State. This parameter provides additional information pertaining to PST and PSTQ.

  • AINS

Automatic in service

  • DSBLD

Disabled

  • LPBK

Loopback

  • MEA

Mismatch of equipment and attributes

  • MT

Maintenance mode

  • OOG

Out of group

  • SWDL

Software downloading

  • UAS

Unassigned

  • UEQ

Unequipped

11.45 ED-LMP-TLINK

(Cisco ONS 15454 SDH) The Edit Link Management Protocol Traffic Engineering (TE) Link (ED-LMP-TLINK) command edits the LMP TE link.

 
Usage Guidelines

This command can only be used on nodes that have the LMP protocol available and enabled.

Category

LMP

Security

Provisioning

Input Format

ED-LMP-TLINK:[<TID>]:<SRC>:<CTAG>:::REMOTEID=<REMOTE_ID>, REMOTETE=<REMOTE_TELINK>, [MUXCAP=<MUXCAP>]:[<PST>[,<SST>]];

Input Example

ED-LMP-TLINK:PETALUMA:TLINK-123:704:::REMOTEID=15.15.15.115,REMOTETE=123,
MUXCAP=LAMBDA:OOS,DSBLD;

Table 11-41 ED-LMP-TLINK Command - Parameter Support

Input Parameters
Description

<SRC>

LMP TE Link AID Values.

  • TLINK-ALL

Specifies all the TE links.

  • TLINK-{1-256}

Specifies an individual TE link.

<REMOTEID>

Remote node ID associated with the LMP TE link.

<REMOTETE>

Remote ID used by the far-end LMP TE Link.

<MUXCAP>

The muxponder capability of the LMP TE link.

  • PKTSWITCH1

Packet Switching 1.

  • PKTSWITCH2

Packet Switching 2.

  • PKTSWITCH3

Packet Switching 3.

  • PKTSWITCH4

Packet Switching 4.

  • LAYER2

Layer 2 switching.

  • TDM

TDM switching.

  • LAMBDA

Lambda switching.

  • FIBER

Fiber switching.

<PST>

Primary State. This parameter indicates the current overall service condition of an entity.

  • IS

In service

  • OOS

Out of service

<SST>

Secondary State. This parameter provides additional information pertaining to PST and PSTQ.

  • AINS

Automatic in service

  • DSBLD

Disabled

  • LPBK

Loopback

  • MEA

Mismatch of equipment and attributes

  • MT

Maintenance mode

  • OOG

Out of group

  • SWDL

Software downloading

  • UAS

Unassigned

  • UEQ

Unequipped

11.46 ED-LMP-DLINK

(Cisco ONS 15454 SDH) The Edit Link Management Protocol Data Link (ED-LMP-DLINK) command edits the LMP data link.

 
Usage Guidelines

This command is only applicable on a node that supports the LMP protocol; the node must have the LMP protocol enabled.

Category

LMP

Security

Provisioning

Input Format

ED-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>],TELINK=<TELINK>,
REMOTEID=<REMOTEID>;

Input Example

ED-LMP-DLINK:PETALUMA:FAC-14-1-1:704:::LINKTYPE=PORT,TELINK=TLNK-45,
REMOTEID=646631;

Table 11-42 ED-LMP-DLINK Command - Parameter Support

Input Parameters
Description

<SRC>

Access identifier from the “FACILITY” section.

<LINKTYPE>

The type of LMP data link.

  • PORT

Port data link

  • COMPONENT

Component data link

<TELINK>

Used to map LMP data links to LMP TE links.

<REMOTEID>

The remote LMP data link ID.

11.47 ED-LNK

(Cisco ONS 15454 SDH) The Edit Link (ED-LNK) command edits an optical link state.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

Category

DWDM

Security

Provisioning

Input Format

ED-LNK:[<TID>]:<FROM>,<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-LNK:PENNGROVE:BAND-6-1-TX,
BAND-13-1-RX:114:::CMDMDE=NORM:UNLOCKED,AUTOMATICINSERVICE;

Table 11-43 ED-LNK Command - Parameter Support

Input Parameters
Description

<FROM>

Identifier at one end of the optical link from the “BAND” section.

<TO>

Identifier at the other end of the optical link from the “BAND” section.

<CMDMDE>

(Optional) Command mode. Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in Unlocked-Enabled or Locked-Disabled, AutomaticInService service states.

  • FRCD

Force the system to override a state in which the command would normally be denied.

  • NORM

Execute the command normally. Do not override any conditions that could make the command fail.

<PST>

(Optional) Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.

Note PST is not supported for OCH provisioning.

  • Unlocked

In service

  • Locked

Out of service

<SST>

(Optional) Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

Note SST is not supported for OCH provisioning.

  • AutomaticInService

Automatic in service

  • Disabled

Disabled

  • Loopback

Loopback

  • MismatchofEquipmentAlarm

Mismatch of equipment and attributes

  • Maintenance

Maintenance mode

  • OutOfGroup

Out of group

  • SoftwareDownload

Software downloading

  • Unassigned

Unassigned

  • NotInstalled

Unequipped

11.48 ED-LNKTERM

(Cisco ONS 15454 SDH) The Edit Provisionable Patchcord Termination (ED-LNKTERM) command edits the attributes of a provisionable patchcord that has already been created. Only the remote end attributes (REMOTENODE, REMOTELNKTERMID) can be edited.

 
Usage Guidelines

  • No two provisionable patchcord terminations on a node can have the same remote end link termination information. An attempt to modify an existing provisionable patchcord termination while not following the above restriction will return an error message.
  • If the provisionable patchcord termination does not exist, an error message will be returned.
  • This command does not accept multiple and ALL AIDs.
  • REMOTENODE is a string with a maximum length of 20 characters.

Category

Provisionable Patchcords

Security

Provisioning

Input Format

ED-LNKTERM:[<TID>]:<AID>:<CTAG>:::[REMOTENODE=<REMOTENODE>],
[REMOTELNKTERMID=<REMOTELNKTERMID>];

Input Example

ED-LNKTERM::LNKTERM-1:CTAG:::REMOTENODE=172.20.208.226,
REMOTELNKTERMID=25;

 

Table 11-44 ED-LNKTERM Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “LNKTERM” section. Indicates a link (provisionable patchcord) termination on the local node.

<REMOTENODE>

(Optional) The node where the other end of the provisionable patchcord resides. This can be an IP address or a valid TID. Defaults to the IP address of the local node/existing value. REMOTENODE is a string.

<REMOTELNKTERMID>

(Optional) The corresponding provisionable patchcord termination on the remote node (as specified by the REMOTENODE parameter). Integer value within the range of 1 to 65535. Defaults to existing value.

11.49 ED-MA-CFM

(Cisco ONS 15454 SDH) The Edit Maintenance Association Connectivity Fault Management (ED-MA-CFM) command edits the maintenance association present on the card.

 
Usage Guidelines

  • This command is applicable only to GE_XP and 10GE_XP cards.
  • The card should be in Layer2 over DMDM mode.
  • The ALL AID is invalid for this command.

Category

Equipment

Security

Provision

Input Format

ED-MA-CFM:[<TID>]:<AID>:<CTAG>:::MANAME=<MANAME>,SVLANID=<SVLANID>,[NEWMANAME=<NEWMANAME>],[NEWSVLANID=<NEWSVLNAID>],[CCENABLE=<CCENABLE>];

Input Example

ED-MA-CFM:454-156:SLOT-1:1:::MANAME=MANAME,SVLANID=4,NEWMANAME=NEWMA,NEWSVLANID=5;

 

Table 11-45 ED-MA-CFM Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “EQPT” section.

<MANAME>

Maintenance Association Name. It is a string. The MA name length should not exceed more than 43 characters.

<SVLANID>

VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs.

<CCENABLE>

Enable or disable Continuos Check messaging

  • Y

Enable

  • N

Disable

<NEWMANAME>

New name for Maintenance Association. It is a string.

<NEWSVLANID>

New service Vlan ID. It is an integer.

11.50 ED-MCAST

(Cisco ONS 15454SDH)

Edit Multicast attributes (ED-MCAST) command is used to modify the Multicast VLAN registration attributes.

 
Usage Guidelines

The default values for all optional parameters are NE default values. These values may not be the current value for a parameter. In order to obtain the current value use RTRV-XX command to retrieve them.

Error conditions:

  • If the AID is invalid, an IIAC (Invalid AID) error message is returned.
  • The "ALL" AID is invalid for this command.

Category

ETHERNET

Security

Provisioning

Input Format

ED-MCAST[:<TID>]:<AID>:<CTAG>[:::MVRSTATE=<MVRSTATE>],[MVRSVLAN=<MVRSVLAN>],[MVRSTARTIP=<MVRSTARTIP>],[MVRIPRANGE=<MVRIPRANGE>],[IGMPONCVLAN=<IGMPONCVLAN>][:];

Input Example

ED-MCAST::SLOT-1-4:321:::MVRSTATE=Y,MVRSVLAN=46,MVRSTARTIP=230.64.72.57
,MVRIPRANGE=20:;

Input Parameters

Table 11-46 ED-MCAST Command - Parameter Support

Input Parameters
Description

<AID>

Equipment aids are used to access specific cards.

  • ALL

It is only used for RTRV-INV, RTRV-EQPT, RTRV-ALM/COND-EQPT commands.

  • SLOT-ALL

The NE equipment AIDs.

  • SLOT[-{1-50}]-{1-6,12-17}

Individual equipment AID of the I/O card units or slots.

<MVRSTATE>

Multicast VLAN Registration status. Default values is - N

  • Y

Enabled

  • N

Disabled

<MVRSVLAN>

Define the SVLAN used to distribute the Multicast stream inside the Network. Default values is 0

<MVRSTARTIP>

Define the first IP Address of the Multicast IP Group.

<MVRIPRANGE>

MVR IP Range. Indicates the number of IP address starting from mvrStartIp used to identified the multicast IP group. It is a number in the range 0..255. Default values is 0

<IGMPONCVLAN>

To Enable IGMP on Customer VLAN.

11.51 ED-MIP-CFM

(Cisco ONS 15454 SDH) The Edit Maintenance Intermediate Point Connectivity Fault Management (ED-MIP-CFM) command edits the maintenance intermediate points on the port.

 
Usage Guidelines

  • This command is applicable only to GE_XP and 10GE_XP cards.
  • The card should be in Layer2 over DMDM mode.

Category

Ports

Security

Provisioning

Input Format

ED-MIP-CFM:[<TID>]:<AID>:<CTAG>:::VLANID=<VLANID>,LEVEL=<LEVEL>;

Input Example

ED-MIP-CFM::ETH-1-1-1:1:::VLANID=2,LEVEL=3;

Input Parameters

<AID>

Access identifier from the “ETH” section.

<VLANID>

VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs.

<LEVEL>

This indicates the level of the maintenance domain. The value ranges from 0 to 7.

11.52 ED-NE-GEN

(Cisco ONS 15454 SDH) The Edit Network Element General (ED-NE-GEN) command edits the node attributes of the NE.

 
Usage Guidelines

  • The node name can be a maximum of 20 characters. If the entered name exceeds 20 characters, an Node Name Too Long (IPNV) error message is returned.
  • An existing NTP timing source can be removed by setting the address to 0.0.0.0.
  • The maximum length of IPADDR and DEFRTR is 20 characters. The default value is the local IP address and default router.
  • The maximum length of IPMASK is 18 characters. The default value is the mask of local IP address.
  • The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
  • An existing NTP and Backup NTP timing source can be removed by setting the address to 0.0.0.0.

Caution Changing the IPADDR, IPMASK, or IIOP Port will cause a reset of the TCC2/TCC2P/TCC3.


NoteOSI parameters are not supported in Release 9.0 and 9.1.


Category

System

Security

Superuser

Input Format

ED-NE-GEN[:<TID>]::<CTAG>[:::NAME=<NAME>],[IPADDR=<IPADDR>],[IPMASK=<IPMASK>],[DEFRTR=<DEFRTR>],[IPV6ADDR=<IPV6ADDR>],[IPV6PREFLEN=<IPV6PREFLEN>],[IPV6DEFRTR=<IPV6DEFRTR>],[IPV6ENABLE=<IPV6ENABLE>],[IIOPPORT=<IIOPPORT>],[NTP=<NTP>],[SUPPRESSIP=<SUPPRESSIP>],[MODE=<MODE>],[MSPUBVLANID=<MSPUBVLANID>],[MSINTLVLANID=<MSINTLVLANID>],[SERIALPORTECHO=<SERIALPORTECHO>],[OSIROUTINGMODE=<OSIROUTINGMODE>],[OSIL1BUFSIZE=<OSIL1BUFSIZE>],[OSIL2BUFSIZE=<OSIL2BUFSIZE>],[BKUPNTP=<BKUPNTP>],[SYSTEMMODE=<SYSTEMMODE>],[FORCEENABLE=<FORCEENABLE>];

Input Example

ED-NE-GEN:CISCO::123:::NAME=NODENAME,IPADDR=192.168.100.52, IPMASK=255.255.255.0,DEFRTR=192.168.100.1,IPV6ADDR=“[3ffe:0501:0008:0000:0260:97ff:efab]”,IPV6PREFLEN=112,IPV6DEFRTR=“[3ffe:0501:0008:0000:0260:97ff:fe40:efab]”,
IPV6ENABLE=Y,IIOPPORT=57790, NTP=192.168.100.52, SUPPRESSIP=NO,
MODE=SINGLESHELF,MSPUBVLANID=1,MSINTLVLANID=5,SERIALPORTECHO=Y,OSIROUTINGMODE=ES,OSIL1BUFSIZE=512,OSIL2BUFSIZE=512,BKUPNTP=10.1.1.2,FORCEENABLE=YES;;

Table 11-47 ED-NE-GEN Command - Parameter Support

Input Parameters
Description

<NAME>

(Optional) Node name. NAME is a string. Defaults to Null.

<IPADDR>

(Optional) Node IP address. IPADDR is a string.

<IPMASK>

(Optional) Node IP mask. IPMASK is a string.

<DEFRTR>

(Optional) Node default router. DEFRTR is a string.

<IPV6ADDR>

Specifies the IPv6 address of the NE. IPV6ADDR is a string.


Note IPV6ADDR parameter can be set only if IPV6ENABLE parameter is set to Y


<IPV6PREFLEN>

Specifies the prefix length for the IPv6 address of the NE. IPV6PREFLEN is an integer

<IPV6DEFRTR>

Specifies the IPv6 default router address for the NE. IPV6DEFRTR is a string

<IPV6ENABLE>

(Optional) Specifies if the IPv6 enable mode for the NE is enabled or disabled.

  • Y

Indicates that IPV6 mode is enabled.

  • N

Indicates that IPV6 mode is disabled.

<IIOPPORT>

(Optional) Node IIOP port. IIOPPORT is an integer. Defaults to 57790.

<NTP>

(Optional) Node Network Time Protocol (NTP) timing origin address. NTP is a string. Defaults to 0.0.0.0.

<SUPPRESSIP>

Suppress the IP display.

  • NO

No

  • YES

Yes

<MODE>

(Optional) Indicates the AID mode to access shelf identifier objects. Defaults to SINGLESHELF. This field is always set to MULTISHELF for DWDM nodes with more than one shelf managed. The parameter type is SHELF_MODE, which is the NE mode.

  • SINGLESHELF

The NE contains only one shelf and the AID representation does not consider the shelf identifier for command requests/response and autonomous reports.

  • MULTISHELF

The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style.

  • MULTISHELFETH

The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style. The shelves are connected by means of an external Ethernet switch.

<MSPUBVLANID>

Public VLAN ID used by the node controller to communicate the with external network. The VLAN ID can be in the range of 1 to 4094. But for M6 shelf, you cannot modify the MSPUBVLANID value. The MSPUBVLANID value is 1.

<MSINTLVLANID>

Internal VLAN ID used by the node controller to communicate with the Subtending shelves. The VLAN ID can be in the range of 1 to 4094. But for M6 shelf, you cannot modify the MSINTLVLANID value. The MSINTLVLANID value is 2.

<SERIALPORTECHO>

Indicates if echo is turned on for the TL1 serial port sessions.

  • Y

Echo is turned on.

  • N

Echo is turned off.

<OSIROUTINGMODE>

Indicates the routing mode of the node.

  • ES

Provisions the node as an OSI ES. The ONS node performs all ES functions and relies upon an IS for communication with other IS nodes inside and outside the ES OSI area.

  • IS1

Provisions the node as an OSI IS. The ONS node performs all IS functions including routing data between ISs and ESs, between networks, and between parts of a network.

  • IS2

The ONS node performs all IS functions. It communicates with other IS and ES nodes within an OSI area. It also broadcasts ISHs to IS nodes in other areas to which it is connected.

<OSIL1BUFSIZE>

Level 1 Link State Protocol Data Unit (LSP) buffer size. The default is 512.

<OSIL2BUFSIZE>

Level 2 Link State Protocol Data Unit (LSP) buffer size. The default is 512.

<BKUPNTP>

Indicates that the Secondary NTP server is used as backup for primary.

<SYSTEMMODE>

Indicates the system mode

  • SONET

SONET

  • SDH

SDH

<FORCEENABLE>

(Optional) Indicates whether the command should proceed even if there are Database Out of Sync alarms.

  • YES

Yes

  • NO

No

11.53 ED-NE-PATH

(Cisco ONS 15454 SDH) The Edit Network Element Path (ED-NE-PATH) command edits the path attributes of the NE.

 
Usage Guidelines

The default values for optional parameters are NE default values.

Category

System

Security

Provisioning

Input Format

ED-NE-PATH:[<TID>]::<CTAG>:::[PDIP=<PDIP>],[XCMODE=<XCMODE>];

Input Example

ED-NE-PATH:::CTAG:::PDIP=Y,XCMODE=MIXED;

Table 11-48 ED-NE-PATH Command - Parameter Support

Input Parameters
Description

<PDIP>

(Optional) Flag used to indicate whether PDI-P should be generated on the outgoing VT structured VCs. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<XCMODE>

(Optional) Cross-connect mode. The parameter type is XCMODE, which is applicable only to a node with cross-connect cards (XC-VXL-10G, XC-VXL-2.5G, or XC-VXC-10G) that support cross-connect mode change.

  • MIXED

Both VC11 and VC12 cross-connects can be provisioned on the node.

  • VC11

Only VC11 cross-connects can be provisioned on the node.

  • VC12

Only VC12 cross-connects can be provisioned on the node.

11.54 ED-NE-SYNCN

(Cisco ONS 15454 SDH) The Edit Network Element Synchronization (ED-NE-SYNCN) command edits the synchronization attributes of the NE.

 
Usage Guidelines

  • The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
  • Although mixed-mode timing is supported in this release, it is not recommended. Refer to the Cisco ONS SDH and Cisco ONS 15600 SDH TL1 Reference Guide for more information.
  • The ONS 15454 SDH mode functionality is:

External mode: The node derives its timing from the BITS inputs.

Line mode: The node derives its timing from the SDH line(s).

Mixed mode: The node derives its timing from the BITS input or SDH lines.


NoteYou cannot edit or retrieve the SSMGEN and QRES parameters on the SDH platform.


Category

Synchronization

Security

Provisioning

Input Format

ED-NE-SYNCN:[<TID>]:[<AID>]:<CTAG>:::[TMMD=<TMMD>],[RVRTV=<RVRTV>],[RVTM=<RVTM>]

;

Input Example

ED-NE-SYNCN:CISCO::123:::TMMD=LINE,RVRTV=Y,RVTM=8.0;

Table 11-49 ED-NE-SYNCN Command - Parameter Support

Input Parameters
Description

<AID>

The node or shelf access identifier from the “SHELF” section. If omitted, it addresses the node or first shelf of the node. Must not be null.

<TMMD>

(Optional) Timing mode. Defaults to EXTERNAL. The parameter type is TIMING_MODE, which is the timing mode for the current node.

  • EXTERNAL

The node derives its clock from the BITS input.

  • LINE

The node derives it’s clock from the SDH lines.

  • MIXED

The node derives it’s clock from the mixed timing mode.

<SSMGEN>

(Optional) Synchronization status message (SSM) set. Defaults to GEN1. The parameter type is SYNC_GENERATION, which is the generation of the synchronization status message set.

  • GEN1

First generation SSM set

  • GEN2

Second generation SSM set

<QRES>

(Optional) Quality of the RES. Defaults to DUS. The parameter type is SYNC_QUALITY_LEVEL, which is the network synchronization quality level.

  • ABOVE-G811

Better than G811

  • ABOVE-STU_SDH

Between STU_SDH and G811 (default setting)

  • ABOVE-G812T

Between G812T and STU_SDH

  • ABOVE-G812L

Between G812L and G812T

  • ABOVE-SETS

Between SETS and G812L

  • BELOW-SETS

Below SETS but still usable

  • SAME-AS-DUS_SDH

Disable the RES message by equating to DUS_SDH

<RVRTV>

(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. A null value is equivalent to ALL. The parameter type is ON_OFF (disable or enable an attribute).

  • N

Does not revert service to original line after restoration.

  • Y

Reverts service to original line after restoration.

<RVTM>

(Optional) Revertive time. A null value is equivalent to ALL. The parameter type is REVERTIVE_TIME (revertive time).

  • 0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes.

<SYSTMN>

(ONS 15454 only) Identifies the system timing standard used by the node.

  • SONET

SONET timing standard

  • SDH

SDH timing standard

11.55 ED-OCH

(Cisco ONS 15454 SDH) The Edit Optical Channel (ED-OCH) command edits the attributes (service parameters) and state of an OCH facility.

 
Usage Guidelines

Refer to the Cisco ONS SDH and Cisco ONS 15600 SDH TL1 Reference Guide for specific card provisioning rules.


NotePrimary=Locked and secondary=AutomaticInService status do not apply to Ethernet mode.


The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.

  • Disable all the ports, before you change the card mode from LAN to WAN mode.
  • The SQUELCHMODE parameter is added to OCH interfaces of 100G-LC-C, 10x10G-LC, and CFP-LC cards.
  • CDLOW and CDHIGH parameters are interdependant. You must set both the parameters to edit either of them.
  • CDLOW is always less than or equal CDHIGH in the range of -70000 to + 70000.

Category

DWDM

Security

Provisioning

Input Format

ED-OCH[:<TID>]:<AID>:<CTAG>[:::EXPWLEN=<EXPWLEN>],[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],[NAME=<PORTNAME>],[OSDBER=<SDBER>],[GCC=<GCC>],[GCCRATE=<GCCRATE>],[DWRAP=<DRWAP>],[FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[SOAK=<SOAK>],[LOSSB=<LOSSB>],[CMDMDE=<CMDMDE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>],[PORTMODE=<PORTMODE>],[ODUTRANSMODE=<ODUTRANSMODE>],[ERRORDECORRELATOR=<ERRORDECORRELATOR>],[FCS=<FCS>],[PPR=<PPR>],[TRIGTH=<TRIGTH>],[RVRTTH=<RVRTTH>],[TRIGWINDOW=<TRIGWINDOW>],[RVRTWINDOW=<RVRTWINDOW>],[OVRCLK=<OVRCLK>],[RXWLEN=<RXWLEN>],[SQUELCHMODE=<SQUELCHMODE>],[FECALMSUPRESS=<FECALMSUPRESS>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[ADMSSM=<ADMSSM>],[CDLOW=<CDLOW>],[CDHIGH=<CDHIGH>],[VOATXPOWER=<VOATXPOWER>],[TXLASERSHUTDN=<TXLASERSHUTDN>][:<PST>[,<SST>]];

Input Example

ED-OCH:CISCO:CHAN-6-2:114:::EXPWLEN=1530.32,NAME="NYLINE",GCC=Y,
GCCRATE=192K,OSDBER=1E-6,DWRAP=Y,FEC=STD,PAYLOADMAP=ASYNCH,
SOAK=10,CMDMDE=FRCD:IS,AINS;

ED-OCH::CHAN-2-2:1:::CDLOW=-6000,CDHIGH=8000,VOATXPOWER=-9.08,TXLASERSHUTDN=Y;

Table 11-50 ED-OCH Command - Parameter Support

Input Parameters
Description

<AID>

Access identifier from the “CHANNEL” section.

<EXPWLEN>

(Optional) Optical wavelength for this port. Applicable only to the following types of cards: optical service channel cards, optical amplifier cards, dispersion compensation units, multiplexer and demultiplexer cards, and optical add/drop multiplexing (OADM) cards. The parameter type is OPTICAL_WLEN, which is the optical wavelength.

  • 1310

Wavelength 1310

  • 1470

Wavelength 1470

  • 1490

Wavelength 1490

  • 1510

Wavelength 1510

  • 1528.77

Wavelength 1528.77

  • 1529.16

Wavelength 1529.16

  • 1529.55

Wavelength 1529.55

  • 1529.94

Wavelength 1529.94

  • 1530

Wavelength 1530

  • 1530.33

Wavelength 1530.33

  • 1530.72

Wavelength 1530.72

  • 1531.12

Wavelength 1531.12

  • 1531.51

Wavelength 1531.51

  • 1531.90

Wavelength 1531.90

  • 1532.29

Wavelength 1532.29

  • 1532.68

Wavelength 1532.68

  • 1533.07

Wavelength 1533.07

  • 1533.47

Wavelength 1533.47

  • 1533.86

Wavelength 1533.86

  • 1534.25

Wavelength 1534.25

  • 1534.64

Wavelength 1534.64

  • 1535.04

Wavelength 1535.04

  • 1535.43

Wavelength 1535.43

  • 1535.82

Wavelength 1535.82

  • 1536.22

Wavelength 1536.22

  • 1536.61

Wavelength 1536.61

  • 1537

Wavelength 1537

  • 1537.40

Wavelength 1537.40

  • 1537.79

Wavelength 1537.79

  • 1538.19

Wavelength 1538.19

  • 1538.58

Wavelength 1538.58

  • 1538.98

Wavelength 1538.98

  • 1539.37

Wavelength 1539.37

  • 1539.77

Wavelength 1539.77

  • 1540.16

Wavelength 1540.16

  • 1540.56

Wavelength 1540.56

  • 1540.95

Wavelength 1540.95

  • 1541.35

Wavelength 1541.35

  • 1541.75

Wavelength 1541.75

  • 1542.14

Wavelength 1542.14

  • 1542.35

Wavelength 1542.35

  • 1542.54

Wavelength 1542.54

  • 1542.94

Wavelength 1542.94

  • 1543.33

Wavelength 1543.33

  • 1543.73

Wavelength 1543.73

  • 1544.13

Wavelength 1544.13

  • 1544.53

Wavelength 1544.53

  • 1544.92

Wavelength 1544.92

  • 1545.32

Wavelength 1545.32

  • 1545.72

Wavelength 1545.72

  • 1546.12

Wavelength 1546.12

  • 1546.52

Wavelength 1546.52

  • 1546.92

Wavelength 1546.92

  • 1547.32

Wavelength 1547.32

  • 1547.72

Wavelength 1547.72

  • 1548.11

Wavelength 1548.11

  • 1548.51

Wavelength 1548.51

  • 1548.91

Wavelength 1548.91

  • 1549.32

Wavelength 1549.32

  • 1549.72

Wavelength 1549.72

  • 1550

Wavelength 1500

  • 1550.12

Wavelength 1550.12

  • 1550.52

Wavelength 1550.52

  • 1550.92

Wavelength 1550.92

  • 1551.32

Wavelength 1551.32

  • 1551.72

Wavelength 1551.72

  • 1552.12

Wavelength 1552.12

  • 1552.52

Wavelength 1552.52

  • 1552.93

Wavelength 1552.93

  • 1553.33

Wavelength 1553.33

  • 1553.73

Wavelength 1553.73

  • 1554.13

Wavelength 1554.13

  • 1554.13

Wavelength 1554.13

  • 1554.94

Wavelength 1554.94

  • 1555.34

Wavelength 1555.34

  • 1555.75

Wavelength 1555.75

  • 1556.15

Wavelength 1556.15

  • 1556.55

Wavelength 1556.55

  • 1556.96

Wavelength 1556.96

  • 1557.36

Wavelength 1557.36

  • 1557.77

Wavelength 1557.77

  • 1558.17

Wavelength 1558.17

  • 1558.58

Wavelength 1558.58

  • 1558.98

Wavelength 1558.98

  • 1559.39

Wavelength 1559.39

  • 1559.79

Wavelength 1559.79

  • 1560.20

Wavelength 1560.20

  • 1560.61

Wavelength 1560.61

  • 1561.01

Wavelength 1561.01

  • 1561.42

Wavelength 1561.42

  • 1561.83

Wavelength 1561.83

  • 1562.23

Wavelength 1562.23

  • 1562.64

Wavelength 1562.64

  • 1563.05

Wavelength 1563.05

  • 1563.45

Wavelength 1563.45

  • 1563.86

Wavelength 1563.86

  • 1564.27

Wavelength 1564.27

  • 1564.68

Wavelength 1564.68

  • 1565.09

Wavelength 1565.09

  • 1565.50

Wavelength 1565.50

  • 1565.90

Wavelength 1565.90

  • 1566.31

Wavelength 1566.31

  • 1566.72

Wavelength 1566.72

  • 1570

Wavelength 1570

  • 1570.83

Wavelength 1570.83

  • 1571.24

Wavelength 1571.24

  • 1571.65

Wavelength 1571.65

  • 1572.06

Wavelength 1572.06

  • 1572.48

Wavelength 1572.48

  • 1572.89

Wavelength 1572.89

  • 1573.30

Wavelength 1573.30

  • 1573.71

Wavelength 1573.71

  • 1574.13

Wavelength 1574.13

  • 1574.54

Wavelength 1574.54

  • 1574.95

Wavelength 1574.95

  • 1575.37

Wavelength 1575.37

  • 1575.78

Wavelength 1575.78

  • 1576.20

Wavelength 1576.20

  • 1576.61

Wavelength 1576.61

  • 1577.03

Wavelength 1577.03

  • 1577.44

Wavelength 1577.44

  • 1577.86

Wavelength 1577.86

  • 1578.27

Wavelength 1578.27

  • 1578.69

Wavelength 1578.69

  • 1579.10

Wavelength 1579.10

  • 1579.52

Wavelength 1579.52

  • 1579.93

Wavelength 1579.93

  • 1580.35

Wavelength 1580.35

  • 1580.77

Wavelength 1580.77

  • 1581.18

Wavelength 1581.18

  • 1581.60

Wavelength 1581.60

  • 1582.02

Wavelength 1582.02

  • 1582.44

Wavelength 1582.44

  • 1582.85

Wavelength 1582.85

  • 1583.27

Wavelength 1583.27

  • 1583.69

Wavelength 1583.69

  • 1584.11

Wavelength 1584.11

  • 1584.53

Wavelength 1584.53

  • 1584.95

Wavelength 1584.95

  • 1585.36

Wavelength 1585.36

  • 1585.78

Wavelength 1585.78

  • 1586.20

Wavelength 1586.20

  • 1586.62

Wavelength 1586.62

  • 1587.04

Wavelength 1587.04

  • 1587.46

Wavelength 1587.46

  • 1587.88

Wavelength 1587.88

  • 1588.30

Wavelength 1588.30

  • 1588.73

Wavelength 1588.73

  • 1589.15

Wavelength 1589.15

  • 1589.57

Wavelength 1589.57

  • 1589.99

Wavelength 1589.99

  • 1590

Wavelength 1590

  • 1590.41

Wavelength 1590.41

  • 1590.83

Wavelength 1590.83

  • 1591.26

Wavelength 1591.26

  • 1591.68

Wavelength 1591.68

  • 1592.10

Wavelength 1592.10

  • 1592.52

Wavelength 1592.52

  • 1592.95

Wavelength 1592.95

  • 1593.37

Wavelength 1593.37

  • 1593.79

Wavelength 1593.79

  • 1594.22

Wavelength 1594.22

  • 1594.64

Wavelength 1594.64

  • 1595.06

Wavelength 1595.06

  • 1595.49

Wavelength 1595.49

  • 1596.34

Wavelength 1596.34

  • 1596.76

Wavelength 1596.76

  • 1597.19

Wavelength 1597.19

  • 1597.62

Wavelength 1597.62

  • 1598.04

Wavelength 1598.04

  • 1598.47

Wavelength 1598.47

  • 1598.89

Wavelength 1598.89

  • 1599.32

Wavelength 1599.32

  • 1599.75

Wavelength 1599.75

  • 1600.06

Wavelength 1600.06

  • 1601.03

Wavelength 1601.03

  • 1601.46

Wavelength 1601.46

  • 1601.88

Wavelength 1601.88

  • 1602.31

Wavelength 1602.31

  • 1602.74

Wavelength 1602.74

  • 1603.17

Wavelength 1603.17

  • 1603.60

Wavelength 1603.60

  • 1604.03

Wavelength 1604.03

  • 1610

Wavelength 1610

  • USE-TWL1

Use Tunable Wavelength 1

<VOAATTN>

(Optional) The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. VOAATTN is a float.

<FCS>

(Optional) First Circuit Startup. An automatic channel startup that operates the VOA when the light is detected on the ingress port.

  • Y

Automatic Channel startup enabled.

  • N

Automatic Channel startup disabled.

<VOAPWR>

(Optional) The value of calibrated output power that the VOA is going to set as a result of its attenuation. VOAPWR is a float.

<CALOPWR>

(Optional) The value of the calibrated optical power expected for the line added to the calculated value, which equals the total expected output power. Expressed in dBm. Defaults to 0 dBm. CALOPWR is a float.

<NAME>

(Optional) Port name. PORTNAME is a string.

<OSDBER>

OTN SDBER. Can only be provisioned on the working port. Defaults to 1E-7

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

  • 1E-5

SDBER is 1E-5

  • 1E-6

SDBER is 1E-6

  • 1E-7

SDBER is 1E-7

  • 1E-8

SDBER is 1E-8

  • 1E-9

SDBER is 1E-9

<GCC>

Identifies the Generic communication channel (GCC) connection of the port.

  • Y

GCC can be utilized

  • N

GCC cannot be utilized

<GCCRATE>

(Optional) The data rate of the GCC traffic. The default is 192 Kbps. For MXP_2.5G_10G and TXP_MR_10G cards, this applies only to the DWDM port. The parameter type is GCCRATE, which is the data rate of the GCC traffic.

  • 192K

192 Kbps

  • 400K

400 Kbps

  • 576K

576 Kbps

  • 1200K

1200 Kbps

<DWRAP>

(Optional) The ITU-T G.709 monitoring digital wrapper. It is either on or off. The system default is ON. For MXP_2.5G_10G and TXP_MR_10G cards, this applies only to the DWDM port. The parameter type is ON_OFF (disable or enable an attribute). To enable ITU-T G.709 monitoring, there should be no GCC on the DWDM port and the payload (in which the card is configured) should not be UNFRAMED. To disable ITU-T G.709 monitoring, there should be no GCC on the DWDM port, the FEC should be turned to off, there should be no overhead circuit created on the DWDM port, and none of the client ports on the card should be part of a Y-cable protection group (muxponder only).

  • N

Disable an attribute.

  • Y

Enable an attribute.

<FEC>

(Optional) Forward error correction. It can be enabled only if ITU-T G.709 monitoring is turned ON. It is either off or enabled in standard or enhanced mode. The system default is standard FEC enabled. The FEC level PM and thresholds apply if the FEC is turned ON. The parameter type is FEC_MODE, which specifies the type of forward error correction.

  • ENH

Enhanced FEC is enabled.

  • ENH-20

20 % Enhanced FEC supported on fixed trunk port of 100G-LC-C card.

  • ENH-I4

Enhanced FEC 1.4 is enabled.

  • ENH-I7

Enhanced FEC 1.7 is enabled.

  • HG-7

High Gain 7% FEC.

  • OFF

FEC is disabled.

  • STD

Standard FEC is enabled.

<PAYLOADMAP>

(Optional) The type of payload mapping. It can be enabled only if ITU-T G.709 monitoring is turned ON and FEC is enabled. The parameter type is PAYLOAD_MAPPING, which is the payload mapping mode.

  • ASYNCH

Asynchronous mapping mode

  • ODU

ODU multiplex structure mode

  • SYNCH

Synchronous mapping mode

  • N

Disable an attribute.

  • Y

Enable an attribute.

  • NOOPU2FIXEDSTUFF

Mapping with no FIXEDSTUFF

<SOAK>

(Optional) Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.

<LOSSB>

The parameter type is REACH which indicates the reach values.

  • 100GBASE-LR4

100GBASE-LR4

  • 100GBASE-SR10

100GBASE-SR10

  • 40GBASE-FR

40GBASE-FR

  • 40GBASE-LR4

40GBASE-LR4

  • 40GBASE-SR4

Reach supported on 40GIGE payload on CFP-LC card.

  • 4I1-9D1F

4I1-9D1F

  • AUTOPROV

Autoprovisioning

  • C4S1-2D1

C4S1-2D1

  • CWDM-40KM

CWDM 40 kilometers.

  • CX

Reach CX

  • CX1

Reach CX1

  • DX

Reach DX

  • FE-BX

FE-BX

  • FX

FX

  • GE-BX

GE-BX

  • GE-EX

GE-EX

  • HX

Reach HX

  • I1

Reach I1

  • IR-1

Reach IR-1

  • IR-2

Reach IR-2

  • L1

Reach L1

  • L2

Reach L2

  • L3

Reach L3

  • LR-1

Reach LR-1

  • LR-2

Reach LR-2

  • LR-3
</