DLT-CRS-ETH:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]; Deletes a cross-connection between the Ethernet paths. |
DLT-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>,<DST>:<CTAG>[:::]; Deletes Y-cable protection on client facilities. |
DLT-LMP-CTRL:[<TID>]:<SRC>:<CTAG>; Deletes a Link Management Protocol (LMP) control channel. |
DLT-LMP-TLINK:[<TID>]:<SRC>:<CTAG>; Deletes an LMP TE link. |
DLT-LMP-DLINK:[<TID>]:<SRC>:<CTAG>; Deletes an LMP data link. |
DLT-LNK:[<TID>]:<FROM>,<TO>:<CTAG>; Deletes an optical link between two optical connection points. |
DLT-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>],[CMDMDE=<CMDMDE>]; Deletes the optical channel (OCH) client connection. |
DLT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]; Deletes the OCH network connection. |
DLT-OSC:[<TID>]:<AID>:<CTAG>; Deletes the optical service channel (OSC) group of the NE. |
DLT-WDMSIDE:[<TID>]:<AID>:<CTAG>[::::]; Deletes a wavelength division multiplexing (WDM) side. |
DLT-WDMANS:[<TID>]:<AID>:<CTAG>::<PARAM>,[<WLEN>][::]; Deletes the automatic optical node setup application attributes. |
ED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>], [CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]] Edits the operating parameters for a DWDM client facility. |
ED-APC:[<TID>]::<CTAG>::[<ROLE>]:[APCENABLE=<APCENABLE>][:]; Modifies the amplification power control (APC) application attributes. |
ED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:]; Edits a Y-cable protection group on client facilities. |
ED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>], [RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:]; Edits the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G or TXPP_MR_2.5G card. |
ED-FFP-OTS:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>], [RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:]; Edits the provisioning for the Y-cable or splitter protection group on the OTU2-XP card. |
ED-LMP:[<TID>]:<AID>:<CTAG>:::[ENABLE=<ENABLE>],[WDM=<WDM>],[ROLE=<ROLE>], [NODEID=<NODEID>[:]; Edits the global LMP attributes. |
ED-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],[REMOTEIP=<REMOTEIP>],[HELLO=<HELLO>], [HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>], [DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>]; Edits an LMP control channel. |
ED-LMP-TLNIK:[<TID>]:<SRC>:<CTAG>:::[REMOTEID=<REMOTEID>], [REMOTETE=<REMOTETE>],[MUXCAP=<MUXCAP>]:[<PST>[,<SST>]]; Edits an LMP TE link. |
ED-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>],[TELINK=<TELINK>], [REMOTEID=<REMOTEID>]; Edits an LMP data link. |
ED-LNK:[<TID>]:<FROM>,<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]: [<PST>[,<SST>]]; Edits an optical link. |
ED-OCH:[<TID>]:<AID>:<CTAG>:::[EXPWLEN=<EXPWLEN>],[VOAATTN=<VOAATTN>], [FCS=<FCS>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],[NAME=<PORTNAME>], [OSDBER=<SDBER>],[GCC=<GCC>],[GCCRATE=<GCCRATE>],[DWRAP=<DRWAP>], [FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[SOAK=<SOAK>],[LOSSB=<LOSSB>], [CMDMDE=<CMDMDE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>], [PORTMODE=<PORTMODE>],[ODUTRANSMODE=<ODUTRANSMODE>], [ERRORDECORRELATOR=<ERRORDECORRELATOR>]:[<PST>[,<SST>]]; Edits the attributes (service parameters) and state of an OCH facility. |
ED-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]]; Edits the OCH client connection. |
ED-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]]; Edits the OCH network connection. |
ED-OMS:[<TID>]:<AID>:<CTAG>[:::EXPBAND=<EXPBAND>],[VOAATTN=<VOAATTN>], [VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],[NAME=<NAME>],[SOAK=<SOAK>], [CMDMDE=<CMDMDE>][:<PST>[,<SST>]]; Edits the attributes (service parameters) and state of an optical multiplex section (OMS) facility. |
ED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,][NODEID=<NODEID>]; Edits the OSC group attributes. |
ED-OTS:[<TID>]:<AID>:<CTAG>[:::VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>], [OFFSET=<OFFSET>],[CALTILT=<CALTILT>],[OSRI=<OSRI>],[NAME=<NAME>], [SOAK=<SOAK>],[<FG>],[<CG>],[CMDMDE=<CMDMDE>][:<PST>[,<SST>]]; Edits the attributes (service parameters) and state of an optical transport section (OTS) facility. |
ED-OTU2:[<TID>]:<AID>:<CTAG>[:::OSDBER=<SDBER>],[GCC=<GCC>], [DWRAP= <DRWAP>],[FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>], [PMMODE= <PMMODE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[NAME=<PORTNAME>], [CMDMDE=<CMDMDE>][:<PST>[,<SST>]];; Edits the attributes (service parameters) and state of an OTU2 facility. |
ED-SLV-WDMANS:[<TID>]:<AID>:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>], [LOWSLVEXP=<LOWSLVEXP>]; Edits the expected span loss verification. |
ED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>],[TRC=<TRC>], [TRCMODE=<TRCMODE>],[TRCLEVEL=<TRCLEVEL>],[TRCFORMAT=<TRCFORMAT>][:]; Edits trace-related OCH facilities. |
ED-WDMANS:[<TID>]:<AID>:<CTAG>::[<WLEN>]:[VOAATTN=<VOAATTN>], [POWEROSC=<POWEROSC>],[NTWTYPE=<NTWTYPE>],[CHLOSS=<CHLOSS>], [GAIN=<GAIN>],[TILT=<TILT>],[CHPWR=<CHPWR>],[AMPLMODE=<AMPLMODE>], [RATIO=<RATIO>],[OSCLOSS=<OSCLOSS>],[DITHER=<DITHER>], [TOTALPWR=<TOTALPWR>],[HIGHSLVEXP=<HIGHSLVEXP>], [LOWSLVEXP=<LOWSLVEXP][:]; Edits the automatic optical node setup (AONS) application attributes. |
ED-WDMSIDE:[<TID>]:<AID>:<CTAG>:::[NEWSIDE=<NEWSIDE>][:]; Modifies the WDM node side attribute. |
ENT-CRS-ETH:[<TID>]:<SRC>,<DST>:<CTAG>::[<ECT>]:[CKTID=<CKTID>][:]; Creates an Ethernet connection. |
ENT-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>,<DST>:<CTAG>:::[PROTTYPE= <PROTTYPE>],[PROTID=<PROTID>],[RVRTV=<RVRTV>],[RVTM=<RVTM>], [PSDIRN=<PSDIRN>][:]; Creates Y cable protection on client facilities. |
ENT-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],REMOTEIP=<REMOTEIP>,[HELLO=<HELLO>], [HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>], [DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>]; Creates an LMP control channel. |
ENT-LMP-TLINK:[<TID>]:<SRC>:<CTAG>:::REMOTEID=<REMOTE_ID>, REMOTETE=<REMOTE_TELINK>, [MUXCAP=<MUXCAP>]:[<PST>[,<SST>]]; Creates an LMP TE link. |
ENT-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>], TELINK=<TELINK>,REMOTEID=<REMOTEID>; Creates an LMP data link. |
ENT-LNK:[<TID>]:<FROM>,<TO>:<CTAG>::::[<PST>[,<SST>]]; Creates an optical link between two optical connection points. |
ENT-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>][,<SST>]; Allocates an OCH client connection. |
ENT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>::[<WCT>]:[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]]; Allocates an OCH network connection. |
ENT-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>], [EAST=<EAST>],[WEST=<WEST>]; Creates the OSC group of the NE. |
ENT-WDMSIDE:[<TID>]:<AID>:<CTAG>:::LINEIN=<LINEIN>,LINEOUT=<LINEOUT>[:]; Adds a new WDM node side and defines its attributes. |
ENT-WDMANS:[<TID>]:<AID>:<CTAG>::[<WLEN>]:[VOAATTN=<VOAATTN>], [POWEROSC=<POWEROSC>],[NTWTYPE=<NTWTYPE>],[CHLOSS=<CHLOSS>], [GAIN=<GAIN>],[TILT=<TILT>],[CHPWR=<CHPWR>],[AMPLMODE=<AMPLMODE>], [RATIO=<RATIO>],[OSCLOSS=<OSCLOSS>],[DITHER=<DITHER>], [TOTALPWR=<TOTALPWR>],[HIGHSLVEXP=<HIGHSLVEXP>], [LOWSLVEXP=<LOWSLVEXP>]; Adds the automatic optical node setup application attributes. |
OPR-APC:[<TID>]::<CTAG>[::::]; Permits the APC application inside the NE to force regulation of the optical power to the entire DWDM ring. |
OPR-LASER-OTS:[<TID>]:<AID>:<CTAG>; Instructs a laser to be switched on. |
OPR-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>::<SW>; Performs a protection switch on the trunk port of a TXPP_MR_2.5G card (protect version only). |
OPR-PROTNSW-OTS:[<TID>]:<AID>:<CTAG>::<SW>; Performs a protection switch on the trunk port of TXPP_MR_2.5G, MXPP_MR_2.5G, Optical Protection Unit, and OTU2-XP cards. |
OPR-SLV-WDMANS:[<TID>]:<AID>:<CTAG>; Invokes the calculation of the expected span loss verification. |
OPR-WDMANS:[<TID>]::<CTAG>; Operates the AONS application inside the NE to force a recalculation of the value to be assigned to all variable optical attenuators (VOA) representing the optical path inside the node. |
RLS-LASER-OTS:[<TID>]:<AID>:<CTAG>; Instructs a laser to be switched off. |
RLS-PROTNSW-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>:<CTAG>[::]; Releases a Y-cable protection switch on client facilities. |
RLS-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>; Performs a protection switch on the trunk port of a TXPP_MR_2.5G card. |
RLS-PROTNSW-OTS:[<TID>]:<AID>:<CTAG>; Releases the protection switch on a TXPP_MR_2.5G card, or a protection switch unit, or a OTU2-XP card. |
RTRV-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the configuration parameter of a DWDM client. Output format: SID DATE TIME M CTAG COMPLD "<AIDUNIONID>,<AIDTYPE>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],[LBCL=<LBCL>], [OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:<PSTPSTQ>,[<SST>]" ; |
RTRV-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::[<CONDTYPE>][,,::]; Retrieves the alarm threshold values. Output format: SID DATE TIME M CTAG COMPLD "<AID>,<MOD>:<CONDTYPE>,,,<THLEVEL>" ; |
RTRV-APC:[<TID>]::<CTAG>; Retrieves the APC application attributes. Output format: SID DATE TIME M CTAG COMPLD "::[APCENABLE=<APCENABLE>,][APCSTATE=<APCSTATE>]" ; |
RTRV-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>:<CTAG>[::::]; Retrieves Y-cable protection on client facilities. Output format: SID DATE TIME M CTAG COMPLD "<AIDUNIONID>,<AIDUNIONID1>::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>]" ; |
RTRV-FFP-OCH:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the protection group information for the TXP_MR_2.5G and TXPP_MR_2.5G trunk port. Output format: SID DATE TIME M CTAG COMPLD "<WORK>,<PROTECT>::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[VRGRDTM=<VRGRDTM>], [DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>],[OPOTYPE=<OPOTYPE>]" ; |
RTRV-FFP-OTS:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the Y-cable or splitter protection group information for the OTU2-XP card. Output format: SID DATE TIME M CTAG COMPLD "<WORK>,<PROTECT>::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>],[RVRTV=<RVRTV>],[RVTM=<RVTM>,[,PSDIRN=<PSDIRN>]" ; |
RTRV-LMP:[<TID>]::<CTAG>; Retrieves the global LMP attributes. Output format: SID DATE TIME M CTAG COMPLD "::ENABLE=<ENABLE>,[WDM=<LOCALPORT>],[ROLE=<ROLE>],[NODEID=<NODEID>], [OPSTATE=<OPSTATE>]" ; |
RTRV-LMP-CTRL:[<TID>]:<SRC>:<CTAG>; Retrieves an LMP control channel. Output format: SID DATE TIME M CTAG COMPLD "<AID>::REMOTEID=<REMOTEID>,LOCALPORT=<LOCALPORT>, REMOTEIP=<REMOTEIP>,[HELLO=<HELLO>],[HELLOMIN=<HELLOMIN>], [HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>],[DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>],[OPSTATE=<OPSTATE>]:[<PST>[,<SST>]] ; |
RTRV-LMP-TLINK:[<TID>]:<SRC>:<CTAG>; Retrieves an LMP TE link. Output format: SID DATE TIME M CTAG COMPLD "<SRC>::[REMOTEID=<REMOTEID>],[DWDM=<DWDM>],[REMOTETE=<REMOTETE>], [MUXCAP=<MUXCAP>],[OPSTATE=<OPSTATE>]:[<PST>[,<SST>]]" ; |
RTRV-LMP-DLINK:[<TID>]:<SRC>:<CTAG>; Retrieves an LMP data link. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[LINKTYPE=<LINKTYPE>],[REMOTEID=<REMOTEID>],[TELINK=<TELINK>], [OPSTATE=<OPSTATE>]" ; |
RTRV-LNK:[<TID>]::<CTAG>; Retrieves all the optical links created in the NE. Output format: SID DATE TIME M CTAG COMPLD "<FROM>,<TO>::[OLNKT=<OLNKT>],[CTYPE=<CTYPE>],[RDIRN=<RDIRN>], [BAND=<BAND>],[WLEN=<WLEN>]:<PST_PSTQ>,[<SST>]" ; |
RTRV-LNK-<MOD2O>:[<TID>]:<AID>:<CTAG>:::[OLNKT=<OLNKT>],[CTYPE=<CTYPE>], [RDIRN=<RDIRN>]; Retrieves any optical link associated with the entered AIDs or AID range. Output format: SID DATE TIME M CTAG COMPLD "<FROM>,<TO>::[OLNKT=<OPTICALLINKTYPE>],[CTYPE=<CREATIONTYPE>], [RDIRN=<RDIRN>],[BAND=<BAND>],[WLEN=<WLEN>]:<PST_PSTQ>,[<SST>]" ; |
RTRV-MACTABLE::SLOT-12:1:::ADDRTYPE=LEARNED-MAC, VLANIDFROM=10, VLANIDTO=20; Retrieves all the MAC addresses stored in the card. |
RTRV-NE-APC:[<TID>]:[<AID>]:<CTAG>; Retrieves the APC application ports that are involved in node setup regulation. Output format: SID DATE TIME M CTAG COMPLD "<AID>,<MOD>::[MODIFDAT=<MODIFDAT>],[MODIFTM=<MODIFTM>], [CHECKDAT=<CHECKDAT>],[CHECKTM=<CHECKTM>]" ; |
RTRV-NE-WDMANS:[<TID>]::<CTAG>; Retrieves the optical node setup (WDMANS) application ports involved in node setup regulation. Output format: SID DATE TIME M CTAG COMPLD "[<AID>],<AIDTYPE>::[REGULATED=<REGULATED>],[PARAM=<PARAM>]" ; |
RTRV-OCH:[<TID>]:<AID>:<CTAG>; Retrieves the attributes (service parameters) and state of an OCH facility. Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[RDIRN=<RDIRN>],[OPTYPE=<OPTICALPORTTYPE>], [OPWR=<POWER>],[EXPWLEN=<EXPWLEN>],[ACTWLEN=<ACTWLEN>], [ILOSS=<ILOSS>],[VOAMODE=<VOAMODE>],[VOAATTN=<VOAATTN>], [VOAPWR=<VOAPWR>],[VOAREFATTN=<VOAREFATTN>], [VOAREFPWR=<VOAREFPWR>],[REFOPWR=<REFOPWR>],[CALOPWR=<CALOPWR>], [CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>], [COMM=<COMM>],[GCCRATE=<GCCRATE>],[DWRAP=<DWRAP>],[FEC=<FEC>], [PAYLOADMAP=<PAYLOADMAP>],[OSPF=<OSPF>],[LBCL=<LBCL>],[OPT=<OPT>], [OPR=<OPR>]:<PST_PSTQ>,[<SSTQ>],[OSFBER=<OSFBER>],[OSDBER=<OSDBER>], [MACADDR=<MACADDR>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]" ; |
RTRV-OCHCC:[<TID>]:<AID>:<CTAG>; Retrieves the OCH client connection provisioning information. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[PAYLOAD=<PAYLOAD>],[CTKID=<CTKID>]:<PSTPSTQ>" ; |
RTRV-OCHNC:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the OCH wavelength connection provisioning information. Output format: SID DATE TIME M CTAG COMPLD "<SRC>,<DST>:<WCT>:[CKTID=<CKTID>]::<PSTPSTQ>" ; |
RTRV-OMS:[<TID>]:<AID>:<CTAG>; Retrieves the attributes (service parameters) and state of an OMS facility. Output format: SID DATE TIME M CTAG COMPLD "<AID>::RDIRN=<RDIRN>,OPTYPE=<OPTICALPORTTYPE>,[OPWR=<POWER>], EXPBAND=<EXPBAND>,[ACTBAND=<ACTBAND>],[ILOSS=<ILOSS>], [VOAMODE=<VOAMODE>],[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>], [VOAREFATTN=<VOAREFATTN>],[VOAREFPWR=<VOAREFPWR>], [REFOPWR=<REFOPWR>],[CALOPWR=<CALOPWR>],[CHPOWER=<CHPOWER>], [NAME=<NAME>]:<PST_PSTQ>,[<SSTQ>]" ; |
RTRV-OPM:[<TID>]:[<AID>]:<CTAG>[::::]; Retrieves the optical power monitoring (OPM) parameters present at the OCH layer in a reconfigurable optical add/drop mode (ROADM) node. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[POWEROUT=<POWEROUT>],[POWERADD=<POWERADD>], [POWERPT=<POWERPT>]" ; |
RTRV-OSC:[<TID>]:<AID>:<CTAG>; Retrieves all of the OSC information of the NE. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[RINGID=<RINGID>],[NODEID=<NODEID>],[EAST=<EAST>],[WEST=<WEST>]" ; |
RTRV-OTS:[<TID>]:<AID>:<CTAG>; Retrieves the attributes (service parameters) and state of an OTS facility. Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:<OPTICALPORTTYPE>,[<POWER>],[<OSCPWR>],[<ILOSS>], [<VOAMODE>],[<VOAATTN>],[<VOAPWR>],[<VOAREFATTN>],[<VOAREFPWR>], [<OSRI>],[<AMPLMODE>],[<AMPLMODEFLG>],[<CHPOWER>],[<CHPOWERFLG>], [<GAIN>],[<EXPGAIN>],[<EXPGAINFLG>],[<REFOPWR>],[<OFFSET>],[<REFTILT>], [<REFTILTFLG>],[<CALTILT>],[<ASEOPWR>],[<DCULOSS>],[<AWGST>],[<HEATST>], [<NAME>],[<SOAK>],[<SOAKLEFT>],[<WRKCHANNELS>],[<RATIO>],[<RAMAN_STATUS>], [<RAMAN_QUALITY>],[<TIME>],[<DATE>],[<RAMAN_RESTORE_FC>],[<TIME_FC>], [<DATE_FC>],[<FG>],[<CG>]:<PST>,[<SST>]"; |
RTRV-PATH-OCH:[<TID>]:<AID>:<CTAG>; Retrieves the OCH path inside a node. Output format: SID DATE TIME M CTAG COMPLD "<AID>:[WLEN],[PATH]:" ; |
RTRV-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>; Retrieves the protection switch status of a TXPP_MR_2.5G card. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<SW>,<SWTYPE>" ; |
RTRV-PROTNSW-OTS:[<TID>]:<AID>:<CTAG>; Retrieves the protection switch status of a TXPP_MR_2.5G card or OTU2-XP card in splitter mode. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<SW>,<SWTYPE>" ; |
RTRV-RAMAN:[<TID>]:<AID>:<CTAG>; Retrieves the attributes of a Raman measure. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<MEAS_INDEX>:<MINRAMANLEV>,<MAXRAMANLEV>,<DATE>,<TIME>" ; |
RTRV-SLV-WDMANS:[<TID>]:<AID>:<CTAG>; Retrieves the options provisionable by the ED-SLV-WDMANS command. Output format: SID DATE TIME M CTAG COMPLD "<AID>:[<ROLE>]:[<HIGHSLVEXP>],[<LOWSLVEXP>],[<SLVACT>],[<RESOLUTION>], [<TYPE>]:" ; |
RTRV-TRC-OCH:[<TID>]:<SRC>:<CTAG>::[<MSGTYPE>],[<TRCLEVEL>][::]; Retrieves the sent trace string, expected trace string, received trace string, trace mode, and the trace level for the SONET J0 Section, the TTI PATH, and the SECTION monitoring levels of the DWDM facility. Output format: SID DATE TIME M CTAG COMPLD "<CHANNEL>,<MOD>::[TRCLEVEL=<TRCLEVEL>],[EXPTRC=<EXPTRC>],[TRC=<TRC>], [INCTRC=<INCTRC>],[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>]" ; |
RTRV-WDMANS:[<TID>]:<AID>:<CTAG>; Retrieves the AONS application attributes. Output format: SID DATE TIME "<AID>:[<WLEN>]:[VOAATTN=<VOAATTN>],[VOAATTNFLG=<VOAATTNFLG>], [POWEROSC=<POWEROSC>],[POWEROSCFLG=<POWEROSCFLG>], [NTWTYPE=<NTWTYPE>],[NTWTYPEFLG=<NTWTYPEFLG>],[CHLOSS=<CHLOSS>],[CHLOSSFLG=<CHLOSSFLG>],[GAIN=<GAIN>],[GAINFLG=<GAINFLG>],[TILT=<TILT>], [TILTFLG=<TILTFLG>],[CHPWR=<CHPWR>],[CHPWRFLG=<CHPWRFLG>], [AMPLMODE=<AMPLMODE>],[AMPLMODEFLG=<AMPLMODEFLG>], [RATIO=<RATIO>],[RATIOFLG=<RATIOFLG>],[OSCLOSS=<OSCLOSS>], [OSCLOSSFLG=<OSCLOSSFLG>],[OPTICALNODETYPE=<OPTICALNODETYPE>], [DITHER=<DITHER>],[DITHERFLG=<DITHERFLG>],[TOTALPWR=<TOTALPWR>], [TOTALPWRFLG=<TOTALPWRFLG>],[HIGHSLVEXP=<HIGHSLVEXP>], [HIGHSLVEXPFLG=<HIGHSLVEXPFLG>],[LOWSLVEXP=<LOWSLVEXP>], [LOWSLVEXPFLG=<LOWSLVEXPFLG>],[LASTCALCDAT=<LASTCALCDAT>], [LASTRUNDAT=<LASTRUNDAT>],[LASTRUNTM=<LASTRUNTM>][:]"; |
RTRV-WDMSIDE:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the WDM side and defines its attributes. Output format: SID DATE TIME M CTAG COMPLD "<AID>::LINEIN=<LINEIN>,LINEOUT=<LINEOUT>,[OCS=<OSC>][:]" ; |
RTRV-WLEN:[<TID>]:<AID>:<CTAG>; Retrieves the wavelength provisioning information. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<CCT>:[SIZE=<SIZE>],[CKTID=<CKTID>],[TOSIDE=<TOSIDE>],[SRC=<SRC>], [DST=<DST>]:<PST_PSTQ>,[<SSTQ>]" ; |
SET-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<CONDTYPE>,<THLEV>[,,,]; Sets alarm thresholds on MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, OSCM, OSC-CSM, OPT-PRE, OPT-BST, MD-4, MUX-32, DMX-32, AD-1C, AD-2C, AD-4C, AD-1B, AD-4B facilities, ports and channels. |