Conditions include any problem detected on an Cisco ONS 15310-MA SDH, Cisco ONS 15454 SDH, and Cisco ONS 15600 SDH shelf. They can include standing or transient notifications. A snapshot of all current raised, standing conditions on the network, node, or card can be retrieved in the Cisco Transport Controller (CTC) Conditions window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are also found in the History tab in CTC.)

Table 26-1 Conditions

Condition
Description
Cisco ONS 15454 SDH
Cisco ONS 15600 SDH
Cisco ONS 15310 MA SDH

AIS

Alarm Indication Signal

Y

Y

Y

AIS-L

Alarm Indication Signal—Line

Y

Y

Y

ALS

Automatic Laser Shutdown

Y

Y

Y

AMPLI-INIT

Optical Amplifier Initialization

Y

Y

Y

APC-DISABLED

Automatic Power Control Disabled

Y

Y

Y

APC-FAIL

Automatic Power Control Failure

Y

Y

Y

APSB

Byte Failure

Y

Y

Y

APSC-IMP

Improper Automatic Protection Switch (APS) Code

Y

Y

Y

APSCDFLTK

Default K Byte

Y

Y

Y

APSCINCON

Inconsistent APS Code

Y

Y

Y

APSCM

Protection Switching Channel Match Failure

Y

Y

Y

APSCNMIS

Node ID Mismatch

Y

Y

Y

APSIMP

APS Invalid Mode

Y

Y

Y

APSMM

APS Mode Mismatch

Y

Y

Y

AS-CMD

Alarms Suppressed By User Command

Y

Y

Y

AS-MT

Alarms Suppressed For Maintenance

Y

Y

Y

AU-AIS

AIS—Administration Unit—Alarm Indication Signal

Y

Y

Y

AU-LOF

LOF—Administration Unit—Loss of Multi Frame

Y

Y

Y

AU-LOP

LOP—Administration Unit—Loss of Pointer

Y

Y

Y

AUD-LOG-LOSS

Audit Log 100 Percent Full—Oldest records will be lost

Y

Y

Y

AUD-LOG-LOW

Audit Log 80 Percent Full

Y

Y

Y

AUTOLSROFF

Automatic Laser Shutoff Due To High Temperature

Y

Y

Y

AUTORESET

Automatic System Reset

Y

Y

Y

AUTOSW-AIS-SNCP

Automatic SNCP Switch caused by AIS

Y

Y

Y

AUTOSW-LOP-SNCP

Automatic SNCP Switch Caused By LOP

Y

Y

Y

AUTOSW-PDI-SNCP

Automatic SNCP Switch Caused By PDI

Y

Y

Y

AUTOSW-SDBER-SNCP

Automatic SNCP Switch Caused By SDBER

Y

Y

Y

AUTOSW-SFBER-SNCP

Automatic SNCP Switch Caused By SFBER

Y

Y

Y

AUTOSW-UNEQ-SNCP

Automatic SNCP Switch Caused By UNEQ

Y

Y

Y

AWG-DEG

AWG Temperature Degrade

Y

Y

Y

AWG-FAIL

AWG Temperature Failure

Y

Y

Y

AWG-OVERTEMP

AWG Over-Temperature

Y

Y

Y

AWG-WARM-UP

AWG Warm Up

Y

Y

Y

BAT-FAIL

Battery Failure

Y

Y

Y

BAT-HGH-VLT

High Volt

Y

Y

Y

BAT-LOW-VLT

Low Volt

Y

Y

Y

BKUPMEMP

Primary Non-Volatile Backup Memory Failure

Y

Y

Y

CARLOSS

Carrier Loss On The LAN

Y

Y

Y

CASETEMP-DEG

Case Temperature Degrade

Y

Y

Y

CKTDOWN

Signaling unable to set up circuit

Y

Y

Y

CLDRESTART

Cold Restart

Y

Y

Y

COMIOXC

IO Slot To XCON Communication Failure

Y

Y

Y

COMM-FAIL

Plug-in Module Communication Failure

Y

Y

Y

CONTBUS-A-18

TCC A To DCC A Processor Communication Failure

Y

Y

Y

CONTBUS-B-18

TCC B To DCC B Processor Communication Failure

Y

Y

Y

CONTBUS_A

Controller A To Shelf Slot Communication Failure

Y

Y

Y

CONTBUS_B

Controller B To Shelf Slot Communication Failure

Y

Y

Y

CTNEQPT-MISMATCH

Connection Equipment Mismatch

Y

Y

Y

CTNEQPT-PBPROT

Interconnection Equipment Failure—Protect XC Payload Bus

Y

Y

Y

CTNEQPT-PBWORK

Interconnection Equipment Failure—Working XC Payload Bus

Y

Y

Y

DATAFLT

Software Fault—Data Integrity Fault

Y

Y

Y

DBOSYNC

Standby Database Out of Sync

Y

Y

Y

DS3-MISM

DS3 Frame Format Mismatch

Y

Y

Y

DSP-COMM-FAIL

DSP Communication Failure

Y

Y

Y

DSP-FAIL

DSP Failure

Y

Y

Y

DUP-IPADDR

IP address already in use within the same DCC Area

Y

Y

Y

DUP-NODENAME

Node name already in use within the same DCC area

Y

Y

Y

E-W-MISMATCH

Both Ends Of Fiber Provisioned As East Or Both As West

Y

Y

Y

E3-ISD

E3 Idle Condition

Y

Y

Y

EHIBATVG

Extreme High Volt

Y

Y

Y

ELWBATVG

Extreme Low Volt

Y

Y

Y

EOC

RS-DCC Termination Failure

Y

Y

Y

EQPT

Equipment Failure

Y

Y

Y

EQPT-MISS

Replaceable Equipment/Unit is Missing

Y

Y

Y

ERFI-P-CONN

Enhanced Remote Failure Indication—Path—Connectivity

Y

Y

Y

ERFI-P-PAYLD

Enhanced Remote Failure Indication—Path—Payload

Y

Y

Y

ERFI-P-SRVR

Enhanced Remote Failure Indication—Path—Server

Y

Y

Y

ERROR-CONFIG

Error in Startup Configuration

Y

Y

Y

ETH-LINKLOSS

Rear Panel Ethernet Link Removed

Y

Y

Y

EXCCOL

Excess Collisions On The LAN

Y

Y

Y

EXERCISE-RING-FAIL

Exercise Request on Ring Failed

Y

Y

N

EXERCISE-RING-REQ

Exercise Request on Ring

Y

Y

N

EXERCISE-SPAN-FAIL

Exercise Request on Span Failed

Y

Y

N

EXERCISE-SPAN-REQ

Exercise Request on Span

Y

Y

N

EXT

Failure Detected External To The NE

Y

Y

Y

EXTRA-TRAF-PREEMPT

Extra Traffic Preempted

Y

Y

N

FAILTOSW

Failure To Switch To Protection

Y

Y

N

FAILTOSW-HO

Failure To Switch To Protection—High Order Path

Y

Y

Y

FAILTOSW-LO

Failure To Switch To Protection—Low Order Path

Y

Y

Y

FAILTOSWR

Failure To Switch To Protection—Ring

Y

Y

N

FAILTOSWS

Failure To Switch To Protection—Span

Y

Y

N

FAN

Fan Failure

Y

Y

Y

FANDEGRADE

Partial Fan Failure

Y

Y

Y

FE-AIS

Far End AIS

Y

Y

Y

FE-DS1-MULTLOS

Far End Multiple DS1 LOS Detected On DS3

Y

Y

N

FE-DS1-NSA

Far End DS1 Equipment Failure—Non Service Affecting

Y

Y

N

FE-DS1-SA

Far End DS1 Equipment Failure—Service Affecting

Y

Y

N

FE-DS1-SNGLLOS

Far End Single DS1 LOS

Y

Y

N

FE-DS3-NSA

Far End DS3 Equipment Failure—Non Service Affecting

Y

Y

Y

FE-DS3-SA

Far End DS3 Equipment Failure—Service Affecting

Y

Y

Y

FE-E1-MULTLOS

Far end multiple E1 LOS detected on E3

Y

Y

Y

FE-E1-NSA

Far end E1 eqpt fail non service affecting

Y

Y

Y

FE-E1-SA

Far end E1 eqpt fail service affecting

Y

Y

Y

FE-E1-SNGLLOS

Far end signal E1 LOS

Y

Y

Y

FE-E3-NSA

Far end E3 eqpt fail non service affecting

Y

Y

Y

FE-E3-SA

Far end E3 eqpt fail service affecting

Y

Y

Y

FE-EQPT-NSA

Far End Common Equipment Failure—Non Service Affecting

Y

Y

Y

FE-EXERCISING-RING

Far End Exercising Ring

Y

Y

N

FE-EXERCISING-SPAN

Far End Exercising Span

Y

Y

N

FE-FRCDWKSWPR-RING

Far End Working Facility Forced To Switch To Protection—Ring

Y

Y

N

FE-FRCDWKSWPR-SPAN

Far End Working Facility Forced To Switch To Protection—Span

Y

Y

N

FE-IDLE

Far End IDLE

Y

Y

Y

FE-LOCKOUTOFPR-ALL

Far End Lockout Of Protection—All Spans

Y

Y

Y

FE-LOCKOUTOFPR-RING

Far End Lockout Of Protection—Ring

Y

Y

N

FE-LOCKOUTOFPR-SPAN

Far End Lockout Of Protection—Span

Y

Y

N

FE-LOCKOUTOFWK-RING

Far End Lockout Of Working—Ring

Y

Y

N

FE-LOCKOUTOFWK-SPAN

Far End Lockout Of Working—Span

Y

Y

N

FE-LOF

Far End LOF

Y

Y

Y

FE-LOS

Far End LOS

Y

Y

Y

FE-MANWKSWPR-RING

Far End Manual Switch Of Working Facility To Protection—Ring

Y

Y

N

FE-MANWKSWPR-SPAN

Far End Manual Switch Of Working Facility To Protection—Span

Y

Y

N

FE-SDPRLF

APS Channel—Far End Protection Line Signal Degrade

Y

Y

Y

FEC-MISM

FEC Mismatch

Y

Y

Y

FEPRLF

Far End Protection Line Failure

Y

Y

Y

FIBERTEMP-DEG

Fiber Temperature Degrade

Y

Y

Y

FORCED-REQ

Forced Switch Request

Y

Y

Y

FORCED-REQ-RING

Forced Switch Request On Ring

Y

Y

N

FORCED-REQ-SPAN

Forced Switch Request On Span

Y

Y

N

FRCDSWTOINT

Forced Switch To Internal Clock

Y

Y

Y

FRCDSWTOPRI

Forced Switch To Primary Reference

Y

Y

Y

FRCDSWTOSEC

Forced Switch To Second Reference

Y

Y

Y

FRCDSWTOTHIRD

Forced Switch To Third Reference

Y

Y

Y

FRNGSYNC

Free Running Synchronization Mode

Y

Y

Y

FSTSYNC

Fast Start Synchronization Mode

Y

Y

Y

FULLPASSTHR-BI

Bidirectional Full Pass Through Is Active

Y

Y

Y

GAIN-HDEG

Optical Amplifier Gain Degrade High

Y

Y

Y

GAIN-HFAIL

Optical Amplifier Gain Failure High

Y

Y

Y

GAIN-LDEG

Optical Amplifier Gain Degrade Low

Y

Y

Y

GAIN-LFAIL

Optical Amplifier Gain Failure Low

Y

Y

Y

GCC-EOC

GCC Termination Failure

Y

Y

Y

GE-OOSYNC

Gigabit Ethernet Out of Sync

Y

Y

Y

HI-LASERBIAS

Equipment High Laser Bias

Y

Y

Y

HI-RXPOWER

Equipment High Receive Power

Y

Y

Y

HI-TXPOWER

Equipment High Transmit Power

Y

Y

Y

HITEMP

High Temperature

Y

Y

Y

HLDOVRSYNC

Holdover Synchronization Mode

Y

Y

Y

HP-RFI

Remote Failure Indication—High Order—Remote Failure/Alarm Indication

Y

Y

Y

HP-TIM

High Order—Trace Identifier Mismatch Failure

Y

Y

Y

HP-UNEQ

Signal Label Mismatch Failure (SLMF)—Unequipped High Order—Path Unequipped

Y

Y

Y

I-HITEMP

Industrial High Temperature

Y

Y

Y

IMPROPRMVL

Improper Removal

Y

Y

Y

INC-GFP-OUTOFFRAME

Out Of Frame Detected by Generic Framing Protocol (GFP) Receiver

Y

Y

Y

INC-GFP-SIGLOSS

Client Signal Loss Frames Detected by GFP Receiver

Y

Y

Y

INC-ISD

DS3 Idle Condition

Y

Y

Y

INC-SIGLOSS

Incoming Signal Loss on Fibre Channel Interface

Y

Y

Y

INC-SYNCLOSS

Incoming Synchronization Loss on Fibre Channel Interface

Y

Y

Y

INC_GFP_SYNCLOSS

Client Synchronization Loss Frames Detected by GFP Receiver

Y

Y

Y

INHSWPR

Inhibit Switch To Protect Request On Equipment

Y

Y

Y

INHSWWKG

Inhibit Switch To Working Request On Equipment

Y

Y

Y

INTRUSION-PSWD

Security Intrusion Attempt Detected—See Audit Log

Y

Y

Y

INVMACADR

Invalid MAC Address

Y

Y

Y

IOSCFGCOPY

Ios Config Copy In Progress

Y

Y

Y

KB-PASSTHR

K Bytes Pass-Through Is Active

Y

Y

Y

KBYTE-APS-CHANNEL-FAILURE

Kbyte Channel Failure

Y

Y

Y

LAN-POL-REV

Lan Connection Polarity Reversed

Y

Y

Y

LASER-APR

Laser Auto Power Reduction

Y

Y

Y

LASERBIAS-DEG

Laser Bias Degrade

Y

Y

Y

LASERBIAS-FAIL

Laser Bias Failure

Y

Y

Y

LASEREOL

Laser Approaching End of Life

Y

Y

Y

LASERTEMP-DEG

Laser Temperature Degrade

Y

Y

Y

LKOUTPR-R

Lockout Of Protection—Ring

Y

Y

N

LKOUTPR-S

Lockout Of Protection—Span

Y

Y

N

LKOUTWK-R

Lockout Of Working—Ring

Y

Y

N

LKOUTWK-S

Lockout Of Working—Span

Y

Y

N

LMP-HELLODOWN

Link Management Protocol (LMP) Hello FSM to Control Channel down

Y

Y

Y

LMP-NDFAIL

LMP Neighbor Discovery has failed

Y

Y

Y

LO-RXPOWER

Equipment Low Receive Power

Y

Y

Y

LO-TXPOWER

Equipment Low Transmit Power

Y

Y

Y

LOA

Loss of Alignment

Y

Y

Y

LOC

Loss of Channel

Y

Y

Y

LOCKOUT-REQ

Lockout Switch Request On Facility or Equipment

Y

Y

Y

LOCKOUT-REQ-RING

Lockout Switch Request On Ring

Y

Y

N

LOCKOUTOFPR

Lockout Of Protection

Y

Y

Y

LOF

Loss Of Frame

Y

Y

Y

LOM

Loss of Multi-Frame

Y

Y

Y

LOS

Loss Of Signal

Y

Y

Y

LOS-CONT

Loss Of Continuity

Y

Y

Y

LP-PLM

Signal Label Mismatch Failure (SLMF)—PLM Low Order—Path Label Mismatch

Y

Y

Y

LP-RFI

RFI—Low Order—Remote Failure/Alarm Indication

Y

Y

Y

LP-TIM

TIM Low Order—Trace Identifier Mismatch Failure

Y

Y

Y

LP-UNEQ

Signal Label Mismatch Failure (SLMF)—Unequipped Low Order—Path Unequipped

Y

Y

Y

LPBKCRS

Cross-connect Loopback

Y

Y

Y

LPBKDS1FEAC

DS1 Loopback Due To Far End Alarm and Control (FEAC) Command

Y

Y

N

LPBKDS3FEAC

DS3 Loopback Due To FEAC Command

Y

Y

Y

LPBKDS3FEAC-CMD

DS3 Loopback Command Sent To Far End

Y

Y

Y

LPBKE1FEAC

E1 loopback due to FEAC command

Y

Y

Y

LPBKE3FEAC

E3 loopback due to FEAC command

Y

Y

Y

LPBKE3FEAC-CMD

E3 loopback command sent to far end

Y

Y

Y

LPBKFACILITY

Facility Loopback

Y

Y

Y

LPBKTERMINAL

Terminal Loopback

Y

Y

Y

MAN-REQ

Manual Switch Request

Y

Y

Y

MANRESET

Manual System Reset

Y

Y

Y

MANSWTOINT

Manual Switch To Internal Clock

Y

Y

Y

MANSWTOPRI

Manual Switch To Primary Reference

Y

Y

Y

MANSWTOSEC

Manual Switch To Second Reference

Y

Y

Y

MANSWTOTHIRD

Manual Switch To Third Reference

Y

Y

Y

MANUAL-REQ-RING

Manual Switch Request On Ring

Y

Y

N

MANUAL-REQ-SPAN

Manual Switch Request On Span

Y

Y

N

MEA

Mismatch Of Equipment And Attributes

Y

Y

Y

MEM-GONE

Free Memory On Card Near Zero

Y

Y

Y

MEM-LOW

Free Memory On Card Very Low

Y

Y

Y

MFGMEM

Manufacturing Data Memory (EEPROM Failure)

Y

Y

Y

MS-AIS

AIS—Multiplex Section—Alarm Indication Signal

Y

Y

Y

MS-EOC

Multiplex Section DCC Termination Failure

Y

Y

Y

MS-RFI

RFI—Multiplex Section—Remote Failure/Alarm Indication

Y

Y

Y

MSSP-OOSYNC

Procedural Error—MS-SPRing out of sync

Y

Y

N

NO-CONFIG

No Startup Configuration

Y

Y

Y

NTWTPINC

Network Topology Incomplete

Y

Y

Y

OCHNC-ACTIV-FAIL

Optical Channel Activation Failure

Y

Y

N

OCHNC-DEACTIV-FAIL

Optical Channel Deactivation Failure

Y

Y

N

OCHNC-FAIL

Optical Channel Connection Failure

Y

Y

N

OCHNC-INC

Optical Channel Incomplete

Y

Y

N

ODUK-AIS-PM

ODUk: Alarm Indication Signal

Y

Y

Y

ODUK-BDI-PM

ODUk: PM Backward Defect Indication

Y

Y

Y

ODUK-LCK-PM

ODUk: Locked Defect —Performance Monitoring (PM)

Y

Y

Y

ODUK-OCI-PM

ODUk: Open Connection Indication

Y

Y

Y

ODUK-SD-PM

ODUk: Signal Degrade

Y

Y

Y

ODUK-SF-PM

ODUk: Signal Failure

Y

Y

Y

ODUK-TIM-PM

ODUk: Trail Trace Identifier Mismatch

Y

Y

Y

OOU-TPT

Out of Use—Transport Failure

Y

Y

Y

OPTNTWMIS

Optical Network Type Mismatch

Y

Y

Y

OPWR-HDEG

Optical Power Degrade High

Y

Y

Y

OPWR-HFAIL

Optical Power Failure High

Y

Y

Y

OPWR-LDEG

Optical Power Degrade Low

Y

Y

Y

OPWR-LFAIL

Optical Power Failure Low

Y

Y

Y

OTUK-AIS

OTUk: Alarm Indication Signal

Y

Y

Y

OTUK-BDI

OTUk: Backward Defect Indication

Y

Y

Y

OTUK-LOF

OTUk: Loss Of Frame

Y

Y

Y

OTUK-SD

OTUk: Signal Degrade

Y

Y

Y

OTUK-SF

OTUk: Signal Failure

Y

Y

Y

OTUK-TIM

OTUk: Trail Trace Identifier Mismatch

Y

Y

Y

OUT-OF-SYNC

8B10B Out of Sync

Y

Y

Y

PDI-P

Payload Defect Indication—Path

Y

Y

Y

PEER-NORESPONSE

Peer Card Not Responding

Y

Y

Y

PORT-CODE-MISM

Pluggable port security code mismatch

Y

Y

Y

PORT-COMM-FAIL

Module Communication Failure

Y

Y

Y

PORT-MISMATCH

Pluggable port rate mismatch

Y

Y

Y

PORT-MISSING

Pluggable port missing

Y

Y

Y

PRC-DUPID

Duplicate Node ID

Y

Y

Y

PROTNA

Protection Unit Not Available

Y

Y

Y

PTIM

Payload Type Identifier Mismatch

Y

Y

Y

PWR-REDUN

Redundant Power Capability Lost

Y

Y

Y

RAI

Remote Alarm Indication

Y

Y

Y

RCVR-MISS

Facility Termination Equipment—Receiver Missing

Y

Y

Y

RFI

Remote Failure Indication

Y

Y

Y

RFI-L

Remote Failure Indication—Line

Y

Y

Y

RING-ID-MIS

Ring Id Mismatch

Y

Y

N

RING-MISMATCH

Far End Of Fiber Is Provisioned With Different Ring ID

Y

Y

N

RING-SW-EAST

Ring Switch Is Active On The East Side

Y

Y

N

RING-SW-WEST

Ring Switch Is Active On The West Side

Y

Y

N

RSVP-HELLODOWN

RSVP Hello FSM to Neighbor down

Y

Y

Y

RUNCFG-SAVENEED

Need to Save Running Config

Y

Y

Y

SD

Signal Degrade

Y

Y

Y

SD-L

Bit Error Rate (BER) Threshold Exceeded For Signal Degrade—Line

Y

Y

Y

SDBER-EXCEED-HO

BER Threshold Exceeded For Signal Degrade—High Order

Y

Y

Y

SF

Signal Failure

Y

Y

Y

SF-L

BER Threshold Exceeded For Signal Failure—Line

Y

Y

Y

SFBER-EXCEED-HO

BER Threshold Exceeded For Signal Failure—High Order

Y

Y

Y

SFTWDOWN

Software Download In Progress

Y

Y

Y

SH-INS-LOSS-VAR-DEG-HIGH

Shutter Insertion Loss Variation Degrade High

Y

Y

Y

SH-INS-LOSS-VAR-DEG-LOW

Shutter Insertion Loss Variation Degrade Low

Y

Y

Y

SHUTTER-OPEN

Shutter Open

Y

Y

Y

SNTP-HOST

Simple Network time Protocol (SNTP) Host Failure

Y

Y

Y

SPAN-SW-EAST

Span Switch Is Active On The East Side

Y

Y

N

SPAN-SW-WEST

Span Switch Is Active On The West Side

Y

Y

N

SQM

Sequence Mismatch

Y

Y

Y

SQUELCH

Ring Is Squelching Traffic

Y

Y

N

SQUELCH-PATH

Squelching Path

Y

Y

N

SQUELCHED

Equipment Squelched

Y

Y

N

SSM-DUS

Do Not Use For Synchronization

Y

Y

Y

SSM-FAIL

Failed To Receive Synchronization Status Message

Y

Y

Y

SSM-LNC

ITU-T G.812—Local Node Clock traceable

Y

Y

Y

SSM-OFF

Synchronization Status Messages Are Disabled On This Interface

Y

Y

Y

SSM-PRC

ITU-T G.811—Primary Reference Clock traceable

Y

Y

Y

SSM-PRS

Stratum 1 Primary Reference Source Traceable

Y

Y

Y

SSM-RES

Reserved For Network Synchronization Use

Y

Y

Y

SSM-SDH-TN

ITU-T G.812—Transit Node Clock traceable

Y

Y

Y

SSM-SETS

ITU-T G.813—Synchronous Equipment Timing Source traceable

Y

Y

Y

SSM-SMC

SDH Minimum Clock Traceable

Y

Y

Y

SSM-ST2

Stratum 2 Traceable

Y

Y

Y

SSM-ST3

Stratum 3 Traceable

Y

Y

Y

SSM-ST3E

Stratum 3E Traceable

Y

Y

Y

SSM-ST4

Stratum 4 Traceable

Y

Y

Y

SSM-STU

Synchronized—Traceability Unknown

Y

Y

Y

SSM-TNC

Transit Node Clock Traceable

Y

Y

Y

SWMTXMOD

Switching Matrix Module Failure

Y

Y

Y

SWTOPRI

Switch To Primary Reference

Y

Y

Y

SWTOSEC

Switch To Second Reference

Y

Y

Y

SWTOTHIRD

Switch To Third Reference

Y

Y

Y

SYNC-FREQ

Synchronization Reference Frequency Out Of Bounds

Y

Y

Y

SYNCPRI

Primary Synchronization Reference Failure

Y

Y

Y

SYNCSEC

Secondary Synchronization Reference Failure

Y

Y

Y

SYNCTHIRD

Third Synchronization Reference Failure

Y

Y

Y

SYSBOOT

System Reboot

Y

Y

Y

TIM

TIM Section—Trace Identifier Mismatch Failure

Y

Y

Y

TIM-MON

TIM Section Monitor—Trace Identifier Mismatch Failure

Y

Y

Y

TPTFAIL

Transport layer failure

Y

Y

Y

TRMT

Transmit Failure

Y

Y

Y

TRMT-MISS

Facility Termination Equipment—Transmitter Missing

Y

Y

Y

TU-AIS

AIS—Tributary Unit—Alarm Indication Signal

Y

Y

Y

TU-LOP

LOP—Tributary Unit—Loss of Pointer

Y

Y

Y

TUNDERRUN

Ethernet Transmit First In First Out Underrun

Y

Y

Y

TX-AIS

Alarm Indication Signal in TX

Y

Y

Y

TX-RAI

Remote Alarm Indication in TX

Y

Y

Y

UNC-WORD

FEC Uncorrected Word

Y

Y

Y

VCG-DEG

VCAT Group Degraded

Y

Y

Y

VCG-DOWN

VCAT Group Down

Y

Y

Y

VOA-HDEG

Variable Optical Attenuator Degrade High

Y

Y

Y

VOA-HFAIL

Variable Optical Attenuator Failure High

Y

Y

Y

VOA-LDEG

Variable Optical Attenuator Degrade Low

Y

Y

Y

VOA-LFAIL

Variable Optical Attenuator Failure Low

Y

Y

Y

WKSWPR

Switched To Protection

Y

Y

Y

WTR

Wait To Restore

Y

Y

Y

WVL-MISMATCH

Equipment Wavelength Mismatch

Y

Y

Y