Cisco ONS 15454 SDH TL1 Command Guide, Release 7.2
Chapter 17, REPT Commands
Downloads: This chapterpdf (PDF - 550.0KB) The complete bookPDF (PDF - 12.29MB) | Feedback

REPT Messages

Table Of Contents

REPT Messages

17.1  REPT ALM <MOD2ALM>

17.2  REPT ALM BITS

17.3  REPT ALM COM

17.4  REPT ALM ENV

17.5  REPT ALM LMP

17.6  REPT ALM EQPT

17.7  REPT ALM SECU

17.8  REPT ALM SYNCN

17.9  REPT DBCHG

17.10  REPT EVT <MOD2ALM>

17.11  REPT EVT BITS

17.12  REPT EVT COM

17.13  REPT EVT ENV

17.14  REPT EVT EQPT

17.15  REPT EVT FXFR

17.16  REPT EVT IOSCFG

17.17  REPT EVT SECU

17.18  REPT EVT SESSION

17.19  REPT EVT SYNCN

17.20  REPT PM <MOD2>

17.21  REPT SW


REPT Messages


This chapter provides report (REPT) messages for the Cisco ONS 15454 SDH.

17.1  REPT ALM <MOD2ALM>

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Report Alarm for 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STM1, STM4, STM16, STM64, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC3,VC4,VC4-2c,VC4-3c,VC4-4c,VC4-8c,VC4-16c,VC4-64c, VC12, VCG, VT1, VT2, or WLEN (REPT ALM <MOD2ALM>) message reports an alarm condition against a facility or a path. See Table 27-1 for supported modifiers by platform.

Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM <MOD2ALM>
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>],
[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM 1GFC
"FAC-2-1:MJ,LOS,SA,08-01,14-25-59,,:\"LOSS OF SIGNAL\",STM4"
;

Output Parameters

<AID>

Access identifier from the "ALL" section.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

NSA

The condition is non-service affecting

SA

The condition is service affecting

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

32-channel demultiplexer for L-band

32WSS-L

32-channel wavelength switch selector for L-band

AD-1B

Optical Add/Drop Multiplexer (OADM) 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Band Filter

AD-4C

OADM 4-Channel Filter

AICI

AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

Any Service, Any Port (ASAP) carrier card with four pluggable interface module (PIM) slots.

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

The Data Communications Channel

DMX-32

Optical De/Multiplexed (DMX) 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical Multiplexer (MUX) 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier card for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel (OSC) Module

PIM-4

Pluggable interface module with 4 pluggable port module (PPM) slots

PPM-1

Pluggable port module with 1 port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622Mbps) optical facilities

STM64-4

A four port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) asynchronous transfer mode (ATM) optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card that has 8 ports over the lower speed slot of the ONS 15454 SDH with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) packet-over-SDH (POS) optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.2  REPT ALM BITS

The Report Alarm Building Integrated Timing Supply (REPT ALM BITS) message reports an alarm condition on a BITS facility.

Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM BITS
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM BITS
"BITS-1:MJ,SYNC,SA,08-01,14-25-59,,:\"LOSS OF TIMING\""
;

Output Parameters

<AID>

Access identifier from the "BITS" section.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

NSA

The condition is non-service affecting

SA

The condition is service affecting

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.


17.3  REPT ALM COM

The Report Alarm Common (REPT ALM COM) message reports an alarm condition when an AID cannot be given, for example, a fan failure is reported using this message.

Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM COM
"[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM COM
"COM:MJ,FAN,NSA,08-01,14-25-59,,:\"FAN FAILURE\""
;

Output Parameters

<AID>

(Optional) Access identifier. Identifies the entity to which the command pertains. Indicates an alarm without AID. AID is a string.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

NSA

The condition is non-service affecting.

SA

The condition is service affecting.

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.


17.4  REPT ALM ENV

The Report Alarm Environment (REPT ALM ENV) message reports a customer-defined condition on an environmental alarm input.

Usage Guidelines

None

Category

Environment

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM ENV
"<AID>:<NTFCNCDE>,<ALMTYPE>,[<OCRDAT>],[<OCRTM>],[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM ENV
"ENV-IN-1:MJ,OPENDR,08-01,14-25-59,\"OPEN DOOR\""
;

Output Parameters

<AID>

Access identifier from the "ENV" section. Identifies an environmental input.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<ALMTYPE>

Abbreviated code identifying the alarm. The parameter type is ENV_ALM, which is the environmental alarm type.

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

ENGTRANS

Standby engine transfer

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUELLEAK

Fuel leak

FUSE

Fuse failure

GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

HATCH

CEV hatch fail

GEN

Generator failure

HIAIR

High airflow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LEVELCON

Level converter

LVDADSL

Secondary asymmetric digital subscriber line (ADSL) low voltage disconnect

LVDBYPAS

Low voltage disconnected bypass

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48 V power supply failure

PWR-139

-139 V power converter

PWR-190

-190 V power converter

PWRMJ

Power supply major

PWRMN

Power supply minor

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

RINGGENMJ

Ringing generator major

RINGGENMN

Ringing generator minor

RTACADSL

AC or AC/rectifier power fail ADSL equipment

RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

RTACPWR

AC or AC/rectifier power fail DCL equipment

RTACPWRENG

Commercial AC fail, site equipped with standby engine

RTBAYPWR

AC power loss distributed power RT bay

RTRVENG

Retrieve standby engine, commercial AC restored

SMOKE

Smoke

TEMP

High-low temperature

TOXICGAS

Toxic gas

TREPEATER

T-repeater shelf

VENTN

Ventilation system failure

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.


17.5  REPT ALM LMP

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Report Alarm Link Management Protocol (REPT ALM LMP) autonomous message is used to report the LMP-FAIL alarms for the control channels and traffic engineering (TE) links.

Usage Guidelines

None.

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME** ATAG REPT ALM LMP "[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

va454-5 1998-06-20 14:30:00
A 814.812 REPT ALM LMP
"CTRL-1:MJ,LMP-FAIL,NSA,08-01,14-25-59,,\"LMP Failure\","
;

Output Parameters

<AID>

The LMP control channel AID value.

CTRL-ALL

Specifies all the control channels.

CTRL-{1-4}

Specifies an individual control channel.

<NTFCNCDE>

The two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The condition is not reported.

<CONDTYPE>

The condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 26 "Conditions" for a list of conditions.

<SRVEFF>

Indicates the effect of the alarm on service.

NSA

The condition is non-service affecting.

SA

The condition is service affecting.

<OCRDAT>

(Optional) Date in YYYY-MM-DD format.

<OCRTM>

(Optional) Time in HH:MM:SS format.

<DESC>

Is a condition, alarm or event description.


17.6  REPT ALM EQPT

The Report Alarm Equipment (REPT ALM EQPT) message reports an alarm condition against an equipment unit or slot.

Usage Guidelines

None

Category

Equipment

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM EQPT
"<AID>:<NTFCNCDE>,<CONDITION>,<SRVEFF>,[<OCRDAT>],[<OCRTM>,,:[<DESC>],
[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM EQPT
"SLOT-7:MJ,CONTR,NSA,08-01,14-25-59,,:\"CONTROLLER FAILURE\",TCC"
;

Output Parameters

<AID>

Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<CONDITION>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

NSA

The condition is non-service affecting.

SA

The condition is service affecting.

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

3- channel demultiplexer for L-band

32WSS-L

32-channel wavelength switch selector for L-band

AD-1B

OADM 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Band Filter

AD-4C

OADM 4-Channel Filter

AICI

AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

ASAP carrier card with four PIM slots

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

Data Communications Channel

DMX-32

Optical DMX 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical MUX 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel Module

PIM-4

Pluggable interface module with 4 PPM slots

PPM-1

Pluggable port module with 1-port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

STM64-4

A four port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card which has 8 ports over the lower speed slot of the ONS 15454 with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.7  REPT ALM SECU

The Report Alarm Security (REPT ALM SECU) message reports the occurrence of an alarmed security event against the NE.

Usage Guidelines

Based on Telcordia TR-NWT-000835, the AID of the security alarm should be the Connection Identifier (CID), which is not currently supported.

The COM or UID is an acceptable substitute for the AID.


Note The INTRUSION-PSWD condition is the only condition that is reported as a standing condition instead of a transient condition. It defaults to NA and is reported by the REPT EVT SECU message. However, it can be reprovisioned to be reported at a higher severity. If the severity of this alarm is higher than NA, it is reported by the REPT ALM SECU message.


Category

Security

Security

Superuser

Output Format

SID DATE TIME
** ATAG REPT ALM SECU
"<AID>:<NOTIFCODE>,<SECUALMTYPE>"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SECU
"COM:CR,INTRUSION-PSWD"
;

Output Parameters

<AID>

Access identifier. Identifies an entity with the condition. Defaults to COM. AID is a string.

<NOTIFCODE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is the two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<SECUALMTYPE>

Security alarm type. It is a subset of the CONDITION type. In this release, the only allowable type is INTRUSION-PSWD. The parameter type is SECUALMTYPE, which is the security alarm type.

INTRUSION-PSWD

Condition raised after an invalid password is used during login. This condition is raised only if the password is used a specific number of times.


17.8  REPT ALM SYNCN

The Report Alarm Synchronization (REPT ALM SYNCH) message reports an alarm condition against a synchronization reference.

Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM SYNCN
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>],
[<EQPTTYPE>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SYNCN
"SYNC-NE:MJ,MAN,SA,08-01,14-25-59,,:\"MANUAL SWITCH\",TCC"
;

Output Parameters

<AID>

Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition.

<NTFCNCDE>

Notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

NSA

The condition is non-service affecting.

SA

The condition is service affecting.

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<DESC>

(Optional) Condition description.

<EQPTTYPE>

(Optional) The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

32 channels demultiplexer for L-band

32WSS-L

32 channels wavelength switch selector for L-band

AD-1B

OADM 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Band Filter

AD-4C

OADM 4-Channel Filter

AICI

The AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

ASAP Carrier card with four PIM slots

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

Data Communications Channel

DMX-32

Optical DMX 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical MUX 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel Module

PIM-4

Pluggable interface module with 4 PPM slots

PPM-1

Pluggable port module with 1-port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four-port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

STM64-4

A four-port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card which has 8 ports over the lower speed slot of the ONS 15454 SDH with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.9  REPT DBCHG

The Report Database Change (REPT DBCHG) message reports any changes on the NE that result from:

TL1 provisioning commands or their graphical user interface (GUI) equivalents containing the verbs: ALW, DLT, ED, ENT, INH, INIT, OPR, RLS, SET, and SW (for example, DLT-EQPT, ENT-CRS-VC3).

External event such as a board insertion.

When secondary state is changed from AutomaticInService state to any other state, no REPT DBCHG messages are generated.

Usage Guidelines

The REPT DBCHG is turned off by default. To turn REPT DBCHG on, you must issue the ALW-MSG-DBCHG command.

<SOURCE> and <USERID> are optional string parameters with a maximum length of 20 characters.

<COMMAND> is a string parameter with a maximum length of 20 characters.

<AID> is a string parameter with a maximum length of 64 characters. Any excess characters will be truncated.

REPT DBCHG messages will be generated every time a roll is performed. A cross-connect delete and add REPT DBCHG message will not be sent every time a roll is performed.

Category

Log

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT DBCHG
"TIME=<TIME>,DATE=<DATE>,[SOURCE=<SOURCE>],[USERID=<USERID>],
DBCHGSEQ=<DBCHGSEQ>:<COMMAND>:[<AID>]:::[<PSTPSTQ>,],<SST>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT DBCHG
"TIME=14-35-46,DATE=99-07-28,SOURCE=123,USERID=CISCO15,DBCHGSEQ=456:
ENT-CRS-VC11:VC11-4-1-2-6-4:::Locked-Enabled, AutomaticInService"
;

Output Parameters

<TIME>

The time of the message triggered by the NE.

<DATE>

The date of the message triggered by the NE.

<SOURCE>

(Optional) An input-command CTAG if present. SOURCE is a string.

<USERID>

(Optional) The user name or user identifier. USERID is a string.

<DBCHGSEQ>

Identifier or range of identifiers to be retrieved. It is a sequential number of the DBCHGSEQ message. DBCHSEQ is an integer

<COMMAND>

The input command or substitute. COMMAND is a string.

<AID>

Access identifier. AID is a string.

<PSTPSTQ>

Administrative state in the PST-PSTQ format. The parameter type is PST_PSTQ, which is the service state of the entity described by the primary state (PST) and a primary state qualifier (PSTQ).

Unlocked-Enabled

In service and normal

Unlocked-Disabled

Out of service and autonomous

Locked-Disabled

Out of service and autonomous and management

Locked-Enabled

Out of service and management

<SST>

Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


17.10  REPT EVT <MOD2ALM>

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Report Event for 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STM1,STM4,STM16,STM64, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC3, VC4, VC4-2c, VC4-3c, VC4-4c, VC4-8c, VC4-16c,VC4-64c, VC12, VCG, VT1, VT2, or WLEN (REPT EVT <MOD2ALM>) message reports the occurrence of a nonalarmed event. In Software Release 5.0 and later, REPT EVT <MOD2ALM> can report the remote monitoring (RMON)-managed threshold crossing alarm. See Table 27-1 for supported modifiers by platform.

Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT <MOD2ALM>
"<AID>:<CONDTYPE>,[<CONDEFF>],,,[<LOCN>],,[<MONVAL>],[<THLEV>],
[<TMPER>]:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT 1GFC
"FAC-5-1:WKSWPR,TC,,,FEND,,12,13,15-MIN:\"WORKING SWITCH TOPROTECTION\",
STM16"
;

Output Parameters

<AID>

Access identifier from the "ALL" section

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<LOCN>

(Optional) Location associated with a particular command in reference to the entity identified by the AID. The parameter type is LOCATION, which is the location where the action is to take place.

FEND

Action occurs on the Far End of the facility.

NEND

Action occurs on the Near End of the facility.

<MONVAL>

(Optional) Monitored value. Value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. MONVAL is a float.

<THLEV>

(Optional) Threshold level. THLEV is a float.

<TMPER>

(Optional) Accumulation time period for performance counters. The parameter type is TMPER, which is the accumulation time period for the performance management center.

1-DAY

Performance parameter accumulation interval length; every 24-hours. For SDH PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.

1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

32 channels demultiplexer for L-band

32WSS-L

32 channels wavelength switch selector for L-band

AD-1B

OADM 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Band Filter

AD-4C

OADM 4-Channel Filter

AICI

AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

ASAP carrier card with four PIM slots

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

Data Communications Channel

DMX-32

Optical DMX 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical MUX 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel Module

PIM-4

Pluggable interface module with 4 PPM slots

PPM-1

Pluggable port module with 1-port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

STM64-4

A four port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card which has 8 ports over the lower speed slot of the ONS 15454 SDH with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.11  REPT EVT BITS

The Report Event Building Integrated Timing Supply (REPT EVT BITS) message reports a nonalarmed event against a BITS facility.

Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT EVT BITS
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT BITS
"BITS-1:SSM-STU,TC,,,,,,,:\"SYNCHRONIZED - TRACEABILITY UNKNOWN\""
;

Output Parameters

<AID>

Access identifier from the "BITS" section.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<DESC>

(Optional) Condition description.


17.12  REPT EVT COM

The Report Event Common (REPT EVT COM) message reports a nonalarmed event against an NE when there is no AID associated with it.

Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT COM
"[<AID>]:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT COM
"COM:CLDRESTART,TC,,,,,,,:\"COLD RESTART\","
;

Output Parameters

<AID>

(Optional) Access identifier. Identifies the entity to which the command pertains. AID is a string.

<CONDTYPE>

(Optional) Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<CONDEFF>

The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<DESC>

(Optional) Condition description.


17.13  REPT EVT ENV

The Report Event Environment (REPT EVT ENV) message reports the occurrence of a nonalarmed event against an environment alarm input.

Usage Guidelines

None

Category

Environment

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT ENV
"<AID>:<ALMTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT ENV
"ENV-IN-2:OPENDR,TC,,,,,,,:\"OPEN DOOR\""
;

Output Parameters

<AID>

Access identifier from the "ENV" section. Identifies an environmental input.

<ALMTYPE>

Abbreviated code identifying the alarm. The parameter type is ENV_ALM, which is the environmental alarm type.

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

ENGTRANS

Standby engine transfer

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUELLEAK

Fuel leak

FUSE

Fuse failure

GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

HATCH

CEV hatch fail

GEN

Generator failure

HIAIR

High airflow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LEVELCON

Level converter

LVDADSL

Secondary ADSL low voltage disconnect

LVDBYPAS

Low voltage disconnect bypass

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48 V power supply failure

PWR-139

-139 V power converter

PWR-190

-190 V power converter

PWRMJ

Power supply major

PWRMN

Power supply minor

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

RINGGENMJ

Ringing generator major

RINGGENMN

Ringing generator minor

RTACADSL

AC or AC/rectifier power fail ADSL equipment

RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

RTACPWR

AC or AC/rectifier power fail DCL equipment

RTACPWRENG

Commercial AC fail, site equipped with standby engine

RTBAYPWR

AC power loss distributed power RT bay

RTRVENG

Retrieve standby engine, commercial AC restored

SMOKE

Smoke

TEMP

High-low temperature

TOXICGAS

Toxic gas

TREPEATER

T-repeater shelf

VENTN

Ventilation system failure

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<DESC>

(Optional) Condition description.


17.14  REPT EVT EQPT

The Report Event Equipment (REPT EVT EQPT) message reports the occurrence of a nonalarmed event against an equipment unit or slot.

Usage Guidelines

None

Category

Equipment

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT EQPT
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT EQPT
"SLOT-7:PLUGIN,TC,,,,,,,:\"EQUIPMENT PLUG-IN\",TCC"
;

Output Parameters

<AID>

Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

32-channel demultiplexer for L-band

32WSS-L

32-channel wavelength switch selector for L-band

AD-1B

OADM 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Bans Filter

AD-4C

OADM 4-Channel Filter

AICI

AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

ASAP carrier card with four PIM slots

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

Data Communications Channel

DMX-32

Optical DMX 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical MUX 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel Module

PIM-4

Pluggable interface module with 4 PPM slots

PPM-1

Pluggable port module with 1-port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

STM64-4

A four-port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card which has 8 ports over the lower speed slot of the ONS 15454 SDH with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.15  REPT EVT FXFR

The Report Event Software Download (REPT EVT FXFR) message reports the FTP software download status of the start, completion, and completed percentage.

Usage Guidelines

The FXFR_RSLT is only sent when the FXFR_STATUS is COMPLD.

The PRCNT_XFRD is only sent when the FXFR_STATUS is IP or COMPLD.

Category

File Transfer

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT FXFR
"<FILENAME>,<FXFR_STATUS>,[<FXFR_RSLT>],[<PRCNT_XFRD>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT FXFR
"NEW.PKG,COMPLD,SUCCESS,21215147"
;

Output Parameters

<FILENAME>

When a package is being transferred between the FTP server and the controller cards, the filename field will contain the string ACTIVE. Following this transfer, if there is a second controller card on the NE, the file will be copied over to the second card during which time REPT EVT FXFR messages will be generated with a filename of STANDBY. FILENAME is a string.

<FXFR_STATUS>

The status of the file transfer: Start, IP (in progress), or COMPLD. The parameter type is TX_STATUS, which is the status of the file transfer.

COMPLD

The file transmission is completed.

IP

The file transmission is in progress.

START

The file transmission is started.

<FXFR_RSLT>

(Optional) The result of the file transfer: Success or Failure. The parameter type is TX_RSLT, which is the result of the file transfer.

FAILURE

A failed result

SUCCESS

A successful result

<PRCNT_XFRD>

(Optional) The percentage transfer complete. PRCNT_XFRD is a string.


17.16  REPT EVT IOSCFG

The Report Event Cisco IOS Configuration File (REPT EVT IOSCFG) message reports the status of copying the Cisco IOS configuration file when the COPY-IOSCFG command is issued.

Usage Guidelines

You can identify if this message is caused by a Cisco IOS configuration file downloading, uploading or merging by looking at the SRC and DEST field in the message. Refer to the COPY-IOSCFG command for more details.

There is no success/failure in the message to indicate the success or failure of the merge process when merging the startup Cisco IOS configuration file to the running configuration file.

Category

File Transfer

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT IOSCFG
"<AID>:<SRC>,<DEST>,<STATUS>,[<RESULT>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT IOSCFG
"SLOT-1:STARTUP,IOS-CONFIG-FILE-IN-NETWORK,COMPLD,SUCCESS"
;

Output Parameters

<AID>

Access identifier from the "EQPT" section. Slot AID for the equipment.

<SRC>

Source access identifier. Specifies where the Cisco IOS config file is copied from. SRC is a string.

<DEST>

Destination. Specifies where the Cisco IOS config file is copied to. DEST is a string.

<STATUS>

The status of COPY-IOSCFG: Start, IP, or COMPLD. The parameter type is TX_STATUS, which is the status of the file transfer.

COMPLD

The file transmission is completed.

IP

The file transmission is in progress.

START

The file transmission is started.

<RESULT>

(Optional) The result of the file transfer: Success or Failure. the parameter type is TX_RSLT, which is the result of the file transfer.

FAILURE

A failed result

SUCCESS

A successful result


17.17  REPT EVT SECU

The Report Event Security (REPT-EVT-SECU) message reports the occurrence of a nonalarmed security event against the NE. Based on Telcordia TR-NWT-000835.

Usage Guidelines

The AID of the security alarm should be the CID, which is not supported in this release. The COM or UID is an acceptable substitute for the AID here. CIDs will be supported in a future release.

For the rule of single failure, single message/alarm, the security alarm will not be reported as REPT ALM COM, because it is reported as REPT ALM SECU.

Because the NE sends this security message as a transient message, to make all TL1 autonomous messages consistent, the TL1 agent reports the security message into REPT EVT SECU.

This message is inhibited by default. A Superuser will have to issue the ALW-MSG-SECU to see this message.

Category

Security

Security

Superuser

Output Format

SID DATE TIME
A ATAG REPT EVT SECU
"<AID>:<DNFIELD>,[<CONDEFF>],,,,,,,:<SECURITY>:<DNFIELD1>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SECU
"COM:LOGIN-FAILURE-PSWD,TC,,,,,,,:\"SECURITY:
INVALID LOGIN - PASSWORD - SEE AUDIT LOG\""
;

Output Parameters

<AID>

Access identifier. Identifies an entity with the condition. Defaults to COM. AID is a string.

<DNFIELD>

String.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

RCV

Receive direction only

TRMT

Transmit direction only

<SECURITY>

The category of condition. SECURITY is a string.

<DNFIELD1>

DNFIELD1 is a string.


17.18  REPT EVT SESSION

The Report Event Session (REPT EVT SESSION) message reports a nonalarmed event related to establishing a session with the NE.

Usage Guidelines

The WARN field might contain different information depending on the type of session-related event.

If the password aging feature has not been enabled (or the feature is enabled but the password is not close to expiring):

/*USER <UID> LOGGED IN <IP/SERIAL PORT*/

If the forced password feature is enforced and the user is logging in for the first time (or the password has expired):

/*PLEASE CHANGE PASSWORD BEFORE CONTINUING*/

If a session is terminated for any reason (except a user timeout), the reason for the session termination is indicated in the warning (<WARN>).

Category

Security

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT SESSION
"<AID>:<EXP>,<PCN>"
"<WARN>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SESSION
"TCCP:YES,5-DAY"
"/* USER TERRI LOGGED IN TO TCCP */"
;

Output Parameters

<AID>

Access identifier. Identifies the NE with which a session is established. AID is a string.

<EXP>

Indicates whether the password is alive (for example, no password updating is required at the moment), expired, or is about to expire. the parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE or the user is locked out of the NE.

NO

No

YES

Yes

<PCN>

The number of days still remaining before the existing password expires. PCN is a string. PCN appears only if EXP=YES and one of the following conditions exists:

The warning period has not been exhausted

The user is a new user establishing a session for the first time and the forced password change policy has been activated.

<WARN>

Free format text containing additional information about the security event. WARN is a string.


17.19  REPT EVT SYNCN

The Report Event Synchronization (REPT EVT SYNCN) message reports the occurrence of a non-alarmed event against a synchronization entity.

Usage Guidelines

None

Categories

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT SYNCN
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SYNCN
"SYNC-NE:SWTOINT,SC,,,,,,,:\"SWITCH TO INTERNAL CLOCK\",TCC"
;

Output Parameters

<AID>

Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Table 26-1 for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

32DMX-L

32-channel demultiplexer for L-band

32WSS-L

32-channel wavelength switch selector for L-band

AD-1B

OADM 1-Band Filter

AD-1C

OADM 1-Channel Filter

AD-2C

OADM 2-Channel Filter

AD-4B

OADM 4-Bans Filter

AD-4C

OADM 4-Channel Filter

AICI

AIC-I card

AIP

Alarm Indication Panel

ALM-PWR

Alarm Power

ASAP-4

ASAP carrier card with four PIM slots

BP

The backplane of the NE

CE-100T-8

8-port 100T card

CE-1000-4

4-port GIGE mapper card

CRFT-TMG

Craft Timing

DCC

Data Communications Channel

DMX-32

Optical DMX 32 Channels

DS3i-N-12

DS3i-N-12 card

E1

E1 card

E1-42

42-port E1 card

E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

E1N

E1N card

E3

E3 card

FILLER_CARD

Filler card

FMEC-SMZ-E1

FMEC card corresponding to E1 card

FMEC-SMZ-E3

FMEC card corresponding to E3 card

FTA

Fan Tray of the NE

FTA1

Fan Tray 1 of the NE

FTA2

Fan Tray 2 of the NE

G1K-4

G1K-4 card

MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

ML100X-8

8-port 100T card with optical interface

MMU

Multiring mesh upgrade unit

MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

MUX-32

Optical MUX 32 Channels

MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

MXP-MR-10DME

10 Gbps datamux with enhanced FEC

OPT-AMP-L

Optical preamplifier for L-band

OPT-BST

Optical booster amplifier

OPT-BST-L

Optical booster for L-band

OPT-PRE

Optical Preamplifier

OSC-CSM

Optical Service Channel with Combiner/Separator Module

OSCM

Optical Service Channel Module

PIM-4

Pluggable interface module with 4 PPM slots

PPM-1

Pluggable port module with 1-port SFP module

SHELF

Shelf entity

STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

STM4-4

A four port STM4 card

STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

STM64-4

A four-port STM64 card

STM64-LR-1

An interface card that supports one or more STM64 optical facilities

STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

STM1IR-STM1SH-
1310-8

An STM1 card which has 8 ports over the lower speed slot of the ONS 15454 SDH with XC-VXL-10G/XC-VXL-2.5G/192

STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

TCC

Timing, Communications, and Control card

TXP-MR-10G

10G Multirate Transponder card

TXP-MR-2.5G

Multirate 2.5G Unprotected

TXPP-MR-2.5G

Multirate 2.5G Protected

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned equipment type

XC-VXC-10G

XC-VXC-10G cross-connect card

XCVXL-10G

XC-VXL-10G cross-connect card

XCVXL-2.5G

XC-VXL-2.5G cross-connect card


17.20  REPT PM <MOD2>

The Report Performance Monitoring for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS3I, DV6000, E1, E3, E4, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, STM4, STM64, STM1, STM16, OCH, OMS, OTS, POS, STM1E, VC3, VC44C, VC38C, VC464C, VC48C, STS36C, VC4, VC416C, VC42C, VC43C, or VC12 (REPT PM <MOD2>) message reports autonomous monitoring statistics as a result of the schedule created by SCHED-PMREPT. See Table 27-1 for supported modifiers by platform.

Usage Guidelines

None

Category

Performance

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT PM <MOD2>
"<AID>:<MONTYPE>,<MONVAL>,<VLDTY>,<lSTM>,<DIRN>,<TMPER>,<MONDAT>,
<MONTM>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT PM 10GFC
"FAC-3-1:CVL,10,PRTL,NEND,BTH,15-MIN,05-25,14-46"
;

Output Parameters

<AID>

Access identifier from the "ALL" section.

<MONTYPE>

Monitored type. The parameter type is ALL_MONTYPE, which is the monitoring type list.

AISSP

Alarm Indication Signal SecondsPath

ALL

All possible values

BBEP

SDH Background Block Errors Path

BBE-PM

OTN—Background Block Errors—Path Monitor Point

BBER

SDH Background Block Error Ratio

BBER-PM

OTN—Background Block Error Ratio—Path Monitor Point expressed as one tenth of a percentage.

BBER-SM

OTN—Background Block Error Ratio—Section Monitor Point expressed as one tenth of a percentage

BBE-SM

OTN—Background Block Errors—Section Monitor Point

BIEC

FEC—Bit Errors Corrected

CGV

8B10B—Code Group Violations

CVCPP

Coding Violations—CP-Bit Path

CVL

Coding Violations—Line

CVP

Coding Violations—Path

CVS

Coding Violations—Section

CVV

Coding Violations—Section

DCG

8B10B—Data Code Groups

ESCPP

Errored Seconds—CPBit Path

ESL

Errored Seconds—Line

ESP

Errored Seconds—Path

ES-PM

OTN—Errored Seconds—Path Monitor Point

ESR

Errored Second—Ratio

ESR-PM

Errored Seconds Ratio—Path monitor Point expressed as one tenth of a percentage

ESR-SM

Errored Seconds Ratio—Section monitor Point expressed as one tenth of a percentage

ESS

Errored Seconds—Section

ES-SM

OTN—Errored Seconds—Section Monitor Point

ESV

Errored Seconds—VC Path

etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

etherStatsCollisions

Number of transmit packets that are collisions

etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets

etherStatsDropEvents

Number of received frames dropped at the port level

etherStatsFragments

The total number of packets received that were less than 64 octets

etherStatsJabbers

The total number of packets received that are longer than 1518 octets

etherStatsOctets

The total number of octets of data

etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

FCP

Failure Count—Line

FC-PM

OTN—Failure Count—Path Monitor Point

FC-SM

OTN—Failure Count—Section Monitor Point

HP-AR

Availability Ratio

HP-BBE

High-Order Path Background Block Error

HP-BBER

High-Order Path Background Block Error Ratio

HP-EB

High-Order Path Errored Block

HP-ES

High-Order Path Errored Second

HP-ESA

High-Order Path Errored Seconds-A

HP-ESB

High-Order Path Errored Seconds-B

HP-ESR

High-Order Path Errored Second Ratio

HP-FC

High-Order Path Failure Count

HP-NPJC-PDET

High Order Path Negative Pointer Justification Count - Path Detected

HP-NPJC-PGEN

High Order Path Pointer Justification Count Seconds - Path Generated

HP-OI

Outage Intensity

HP-PJCDIFF

High Order Path Pointer Justification Count Difference

HP-PJCS-PDET

High Order Path Pointer Justification Count

HP-PPJC-PDET

High Order Path Positive Pointer Justification Count

HP-PPJC-PGEN

High Order Path, Positive Pointer Justification Count

HP-SEPI

The number of SEP events in available time

HP-SES

High-Order Path Severely Errored Seconds

HP-SESR

High-Order Path Severely Errored Second Ratio

HP-UAS

High-Order Path Unavailable Seconds

ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

ifInDiscards

The number of inbound packets

ifInErrorBytePktss

Receive Error Byte

ifInErrors

The number of inbound packets (or transmission units) that contained errors

ifInFramingErrorPkts

Receive Framing Error

ifInJunkInterPkts

Receive Interpacket Junk

ifInMulticastPkts

Number of multicast packets received since the last counter reset

ifInOctets

Number of bytes transmitted since the last counter reset

ifInUcastPkts

Number of unicast packets received since the last counter reset

ifOutBroadcastPkts

Number of broadcast packets transmitted

ifOutDiscards

The number of outbound packets

ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

ifOutMulticastPkts

Number of multicast packets transmitted

ifOutPayloadCrcErrors

Received payload CRC errors

ifOutUcastPkts

Number of unicast packets transmitted

IOS

8B10B-Idle Ordered Sets

IPC

Invalid Packet Count

LBCL-AVG

Average Laser Bias current in microA

LBCL-MAX

Maximum Laser Bias current in microA

LBCL-MIN

Minimum Laser Bias current in microA

LBCN

Normalized Laser Bias Current for STM1-8

LBCN-HWT

Laser Bias current

LBCN-LWT

Laser Bias current

LOSSL

Loss of Signal Seconds—Line

LP-BBE

Low-Order Path Background Block Error

LP-BBER

Low-Order Path Background Block Error Ratio

LP-EB

Low-Order Path Errored Block

LP-ES

Low-Order Path Errored Second

LP-ESA

Low-Order Path Errored Seconds-A

LP-ESB

Low-Order Path Errored Seconds-B

LP-ESR

Low-Order Path Errored Second Ratio

LP-FC

Low-Order Path Failure Count

LP-NPJC-DET

Low Order Negative Pointer Justification Count, Detected

LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

LP-PPJC-DET

Low Order Positive Pointer Justification Count, Detected

LP-PPJC-GEN

Low Order positive Pointer Justification Count, Generated

LP-SEP

A sequence of between 3 to 9 consecutive SES

LP-SEPI

Low-Order Path Severely Errored Period Intensity

LP-SES

Low-Order Path Severely Errored Seconds

LP-UAS

Low-Order Path Unavailable Seconds

MS-PSC

Protection switch count

MS-PSD

Protection switch duration

NIOS

8B10B—Non Idle Ordered Sets

NPJC-PDET

Negative Pointer Justification Count - Path Detected

NPJC-PGEN

Negative Pointer Justification Count - Path Generated

OPR-AVG

Average Receive Power in tenths of a microW

OPR-MAX

Maximum Receive Power in tenths of a microW

OPR-MIN

Minimum Receive Power in tenths of a microW

OPRN

Normalized Optical Receive Power for STM1-8

OPRN-MAX

Maximum value for OPRN

OPRN-MIN

Minimum value for OPRN

OPT-AVG

Average Transmit Power in tenths of a microW

OPT-MAX

Maximum Transmit Power in tenths of a microW

OPT-MIN

Minimum Transmit Power in tenths of a microW

OPTN

Normalized value for Optical Power Transmitted for STM1-8 card

OPTN-MAX

Maximum value for OPTN

OPTN-MIN

Minimum value for OPTN

OPWR-AVG

Optical Power—Average Interval Value in tenths of a dBm

OPWR-MAX

Optical Power—Maximum Interval Value in tenths of a dBm

OPWR-MIN

Optical Power—Minimum Interval Value in tenths of a dBm

PPJC-PDET

Positive Pointer Justification Count - Path Detected

PPJC-PGEN

Positive Pointer Justification Count - Path Generated

PSC

Protection Switching Count

PSC-R

Protection Switching Count—Ring

PSC-S

Protection Switching Count—Span

PSC-W

Protection Switching Count—Working

PSD

Protection Switching Duration

PSD-R

Protection Switching Duration—Ring

PSD-S

Protection Switching Duration—Span

PSD-W

Protection Switching Duration—Working

SASCPP

Severely Errored Framing/AIS Second—CP-Bit Path

SASP

Severely Errored Framing/AIS Seconds Path

SEFS

Severely Errored Framing Seconds

SESCPP

Severely Errored Second—CP-Bit Path

SESL

Severely Errored Second—Line

SESP

Severely Errored Second—Path

SES-PM

OTN—Severely Errored Second—Path

SESR

Severely Errored Second—Ratio

SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as one tenth of a percentage

SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as one tenth of a percentage

SESS

Severely Errored Second—Section

SES-SM

OTN—Severely Errored Second—Section Monitor Point

SESV

Severely Errored Second—VC Path

UASCPP

Unavailable Second—CP-Bit Path

UASL

Unavailable Second—Line

UASP

Unavailable Second—Path

UAS-PM

OTN—Unavailable Second—Path Monitor Point

UAS-SM

OTN—Unavailable Second—Section Monitor Point

UASV

Unavailable Second—VC Path

UNC-WORDS

FEC—Uncorrectable Words

VPC

Valid Packet Count

<MONVAL>

The value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. MONVAL is a string.

<VLDTY>

Indicates whether the information for the specified time period was accumulated over the entire time period or some portion thereof. Validity indicator for the reported PM data. The parameter type is VALIDITY, which is the response validity.

COMPL

Complete response

PRTL

Partial response

<lSTM>

Location associated with a particular command in reference to the entity identified by the AID. The parameter type is LOCATION, which is the location where the action is to take place.

FEND

Action occurs on the Far End of the facility.

NEND

Action occurs on the Near End of the facility.

<DIRN>

Direction relative to the entity identified by the AID. Direction of PM relative to the entity identified by the AID. The parameter type is DIRECTION (transmit and receive directions).

BTH

Both transmit and receive directions

RCV

Receive direction only

TRMT

Transmit direction only

<TMPER>

Accumulation time period for performance counters. The parameter type is TMPER, which is the accumulation time period for the performance management center.

1-DAY

Performance parameter accumulation interval length; every 24-hours. For SDH PM data only one day of history data is available. For RMON managed PM data, seven days of history data are available.

1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.

<MONDAT>

The beginning date of the PM or storage register period specified in TMPER. The format is MM-DD. MONDAT is a string.

<MONTM>

The beginning time of day of the PM or storage register period specified in TMPER. The format is HH-MM. MONTM is a string.


17.21  REPT SW

The Report Switch (REPT SW) message reports the autonomous switching of a unit in a duplex equipment pair to the standby state and its mate unit to the active state. An automatic report for the occurrence or clearance of an alarm or event that triggers the switch might be associated with the message.

Usage Guidelines

None

Category

Protection

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT SW
"<ACTID>,<STDBYID>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT SW
"SLOT-8,SLOT-10"
;

Output Parameters

<ACTID>

Identifies the equipment unit from the "EQPT" section that was placed in the active state. Parameter grouping cannot be used with this parameter.

<STDBYID>

Identifies the equipment unit from the "EQPT" section that was placed in the standby state. Parameter grouping cannot be used with this parameter.