Cisco ONS 15454 SDH TL1 Command Guide, Release 7.0.1
Chapter 25, Access Identifiers
Downloads: This chapterpdf (PDF - 371.0KB) The complete bookPDF (PDF - 12.04MB) | Feedback

Access Identifiers

Table Of Contents

Access Identifiers

25.1  ALL

25.1.1  AidUnionId

25.1.2  AidUnionId1

25.1.3  BAND

25.1.4  BANDWL

25.1.5  BITS

25.1.6  CHANNEL

25.1.7  COM

25.1.8  CrossConnectId

25.1.9  CrossConnectId1

25.1.10  ENV

25.1.11  EQPT

25.1.12  FACILITY

25.1.13  IPADDR

25.1.14  LINE

25.1.15  LINEWL

25.1.16  LNKTERM

25.1.17  MSSPR

25.1.18  OPM

25.1.19  OSC

25.1.20  PRSLOT

25.1.21  RFILE

25.1.22  SHELF

25.1.23  SYN

25.1.24  SYN_SRC

25.1.25  SYNC_REF

25.1.26  SYNCSW

25.1.27  UDC

25.1.28  VC

25.1.29  WDMANS

25.1.30  WLEN

25.2  CTC Port Numbers and TL1 Aids


Access Identifiers


This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the
Cisco ONS 15454 SDH.

The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code.

25.1  ALL

Table 25-1 ALL 

AID
Pattern

AidUnionId

FACILITY

VC

 

AidUnionId1

MS-SPRing

 

BAND

ALL

BAND[-{1-8}]-{1-6,12-17}-{1-4}-ALL

BAND[-{1-8}]-{1-6,12-17}-{1-4}-{RX,TX}

BAND[-{1-8}]-{1-6,12-17}-{1}-ALL

BAND[-{1-8}]-{1-6,12-17}-{1}-{RX,TX}

 

BANDWL

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

BANDWL-[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-<WLEN>

BANDWL-[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

BITS

ALL

BITS-ALL

BITS[<SHELFID>]-ALL

BITS[<SHELFID>]-{1,2}

SYNC[<SHELFID>]-BITS{1,2}

 

CHANNEL

ALL

CHAN[-{1-8}]-{1-6,12-17}-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-32}-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-32}-{RX,TX}

CHAN[-{1-8}]-{1-6,12-17}-{1-4}-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-4}-{RX,TX}

CHAN[-{1-8}]-{1-6,12-17}-{2,3}

CHAN[-{1-8}]-{1-6,12-17}-{5}

CHAN[-{1-8}]-{1-6,12-17}-{9,10}

 

COM

Common

 

CrossConnectId

FACILITY

 

CrossConnectId1

VCM

FACILITY

VC

 

ENV

ALL

ENV-IN-ALL

ENV-IN[-{1-8}]-ALL

ENV-IN[-{1-8}]-{1-20}

ENV-IN[-{1-8}]-{1-32}

ENV-IN[-{1-8}]-{1-3}

ENV-IN[-{1-8}]-{1-4}

ENV-IN[-{1-8}]-{1-6}

ENV-OUT-ALL

ENV-OUT[-{1-8}]-ALL

ENV-OUT[-{1-8}]-{1-16}

ENV-OUT[-{1-8}]-{1-2}

ENV-OUT[-{1-8}]-{1-4}

ENV-{IN,OUT}[-{1-8}]-{1-16}

EQPT

ALL

AIP-ALL

AIP[-{1-8}]

BIC-ALL

BIC[-{1-8}]-ALL

BIC[-{1-8}]-{A,B}

BP-ALL

BP[-{1-8}]

FAN-ALL

FAN[-{1-8}]

PPM-{1-6,12-17}-1

PPM-{1-6,12-17}-{1-12}

PPM[-{1-8}]-{1-6,12-17}-{1-4}

PPM[-{1-8}]-{1-6,12-17}-{1-8}

PWR-ALL

PWR[-{1-8}]-ALL

PWR[-{1-8}]-{A,B}

SLOT-ALL

SLOT[-{1-8}]-ALL

SLOT[-{1-8}]-{1-17}

SLOT[-{1-8}]-{1-6,12-17}

FACILITY

ALL

FAC[-{1-8}]-{1-4,14-17}-{1-8}

FAC[-{1-8}]-{1-6,12-17}-1

FAC[-{1-8}]-{1-6,12-17}-ALL

FAC[-{1-8}]-{1-6,12-17}-{0-11}

FAC[-{1-8}]-{1-6,12-17}-{0-1}

FAC[-{1-8}]-{1-6,12-17}-{1-12,14,16,18,20,22,24,
26,28,30,32,34,36}

FAC[-{1-8}]-{1-6,12-17}-{1-12,14,16,18,20,22,24}

FAC[-{1-8}]-{1-6,12-17}-{1-4}

FAC[-{1-8}]-{1-6,12-17}-{1-6}

FAC[-{1-8}]-{1-6,12-17}-{1}

FAC[-{1-8}]-{5,6,12,13}-{1}

FAC[-{1-8}]-{8,10}-{1}

VFAC[-{1-8}]-{1-6,12-17}-{0-1}

VFAC[-{1-8}]-{1-6,12-17}-{1,2}

VFAC[-{1-8}]-{1-6,12-17}-{1,2}-{1,8}

IPADDR

111.222.333.444

 

LINE

LINE[-{1-8}]-{1-6,12-17}-{1-2}-ALL

LINE[-{1-8}]-{1-6,12-17}-{1-2}-{RX,TX}

LINE[-{1-8}]-{1-6,12-17}-{1-3}-ALL

LINE[-{1-8}]-{1-6,12-17}-{1-3}-{RX,TX}

LINE[-{1-8}]-{8,10}-{1}-ALL

LINE[-{1-8}]-{8,10}-{1}-{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{1}-{RX,TX}(COM)

LINE-[{1-8}-]{1-6,12-17}-{2}-{RX,TX}(OSC)

LINE-[{1-8}-]{1-6,12-17}-{3}-{RX,TX}(LINE)

LINE-[{1-8}-]{1-6,12-17}-{1-3}-ALL

LINE-[{1-8}-]{1-6,12-17}-{1}-{RX,TX}(LINE)

LINE-[{1-8}-]{1-6,12-17}-{2}-{RX,TX}(COM)

LINE-[{1-8}-]{1-6,12-17}-{3}-{RX,TX}(OSC)

LINE-[{1-8}-]{1-6,12-17}-{4}-{RX,TX}(DC)

LINE-[{1-8}-]{1-6,12-17}-{1-4}-ALL

LINE-[{1-8}-]{1-6,12-17}-1-RX (For input OTS)

LINE-[{1-8}-]{1-6,12-17}-1-ALL

CHAN-[{1-8}-]{1-6,12-17}-{1-32}-TX (For drop OCH)

CHAN-[{1-8}-]{1-6,12-17}-{1-32}-ALL

LINE-[{1-8}-]{1-5,12-16}-{1}-{RX,TX} (EXP)

LINE-[{1-8}-]{1-5,12-16}-{2}-{RX,TX} (COM)

LINE-[{1-8}-]{1-5,12-16}-{3}-{TX} (DROP)

LINE-[{1-8}-]{1-5,12-16}-{1-3}-ALL

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-{RX} (ADD)

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-{PT} (PT)

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-ALL

LINE-[{1-8}-]{1-6,12-17}-{1}-{RX,TX} (EXP)

LINE-[{1-8}-]{1-6,12-17}-{2}-{RX,TX} (COM)

LINE-[{1-8}-]{1-6,12-17}-{3}-{RX,TX} (EXP to other ring)

LINE-[{1-8}-]{1-6,12-17}-{1-3}-ALL

LINEWL

LINEWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

LINEWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

LINEWL-[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-<WLEN>

LINEWL -[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

MS-SPRing

MSSPR-RINGID

 

OPM

ALL

OPM[-{1-8}]-{1-5,12-16}-<WLEN>

OPM[-{1-8}]-{1-5,12-16}-ALL

OSC

OSC-RINGID

 

PRSLOT

NULL

SLOT-1

SLOT-13

SLOT-15

SLOT-17

SLOT-3

SLOT-5

 

RFILE

RFILE-DB

RFILE-LOG

RFILE-PKG

RFILE-COMPDB

 

SHELF

SHELF-ALL

SHELF-{1-8}

 

SYN

SYNC-NE

 

SYN_SRC

BITS-1

BITS-2

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1}

FAC-{5,6,12,13}-{1}

INTERNAL

NONE

STM1-{2}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

SYNC-NE

SYNC_REF

SYNC-ALL

SYNC-NE

SYNC-{BITS1,BITS2}

 

SYNCSW

INT

PRI

SEC

 

UDC

UDC-{F,DCC}-{A,B}

 

VC

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-1-{1-7}-{1-2}

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3-{1-6,12-17}-{1-4}-{1-3}

VC4-{1-4,11-14}-{1-16}-1

VC4-{1-4,11-14}-{1-16}-{1,5,9,13}

VC4-{1-4,11-14}-{1-16}-{1,9}

VC4-{1-4,11-14}-{1-4}-1

VC4-{1-4,11-14}-{1-4}-{1,17,33,49}

VC4-{1-4,11-14}-{1-4}-{1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61}

VC4-{1-4,11-14}-{1-4}-{1,9,17,25,33,41,49,57}

VC4-{1-4,11-14}-{1-4}-{1-64}

VC4-{1-4,14-17}-1

VC4-{1-4,14-17}-1-1

VC4-{1-4,14-17}-{1-12}-1

VC4-{1-4,14-17}-{1-4}-1

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4-{1-4,14-17}-{1-8}-1

VC4-{1-6,12-17}-1

VC4-{1-6,12-17}-1-1

VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,
15}

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-{1-6,12-17}-1-{1-16}

VC4-{1-6,12-17}-1-{1-2}

VC4-{1-6,12-17}-1-{1-3}

VC4-{1-6,12-17}-1-{1-4}

VC4-{1-6,12-17}-1-{1-9}

VC4-{1-6,12-17}-{1-4}

VC4-{1-6,12-17}-{1-4}-1

WDMANS

AONS-{E,W}

WDMANS-{E,W}

 

WLEN

WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90,1532.68,1534.25,1535.04,1535.82,
1536.61,1538.19,1538.98,1539.77,1540.56,1542.14,1542.94,1543.73,1544.53,1546.12,
1546.92,,1547.72,1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,1554.94,1555.75,1556.55,
1558.17,1558.98,1559.79,1560.61}


25.1.1  AidUnionId

Table 25-2 AidUnionId 

AID
Patterns
Facility

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,
30,32,34,36}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-12}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

VFAC-{1,2,5,6}-{1-8}

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}
VC

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-1-{1-7}-{1-2}

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3-{1-6,12-17}-{1-4}-{1-3}

VC4-{1-4,11-14}-{1-16}-1

VC4-{1-4,11-14}-{1-16}-{1,5,9,13}

VC4-{1-4,11-14}-{1-16}-{1,9}

VC4-{1-4,11-14}-{1-4}-1

VC4-{1-4,11-14}-{1-4}-{1,17,33,49}

VC4-{1-4,11-14}-{1-4}-
{1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61}

VC4-{1-4,11-14}-{1-4}-{1,9,17,25,33,41,49,57}

VC4-{1-4,11-14}-{1-4}-{1-64}

VC4-{1-4,14-17}-1

VC4-{1-4,14-17}-1-1

VC4-{1-4,14-17}-{1-12}-1

VC4-{1-4,14-17}-{1-4}-1

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4-{1-4,14-17}-{1-8}-1

VC4-{1-6,12-17}-1

VC4-{1-6,12-17}-1-1

VC4-{1-6,12-17}-1-
{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-{1-6,12-17}-1-{1-16}

VC4-{1-6,12-17}-1-{1-2}

VC4-{1-6,12-17}-1-{1-3}

VC4-{1-6,12-17}-1-{1-4}

VC4-{1-6,12-17}-1-{1-9}

VC4-{1-6,12-17}-{1-4}

VC4-{1-6,12-17}-{1-4}-1


25.1.2  AidUnionId1

Table 25-3 AidUnionId1 

AID
Patterns

MS-SPRing

ALL

MSSPR-RINGID


25.1.3  BAND

The BAND AID is used to access Optical Multiplex Section (OMS) layer of optical networking units.

Table 25-4 BAND 

Pattern
Description

ALL

All of the OMSs of the NE. The ALL AID is applicable for retrieve-only commands.

BAND[-{1-8}]-{1-6,12-17}-{1-4}-ALL

All the channels in a Band OADM (1Bn, 4Bn) unit.

BAND[-{1-8}]-{1-6,12-17}-{1-4}-{RX,TX}

The Receive/Transmit channels in a Band OADM (1Bn, 4Bn) unit.

BAND[-{1-8}]-{1-6,12-17}-{1}-ALL

All the channels in an Optical Multiplexer/Demultiplexer (4Ch) unit.

BAND[-{1-8}]-{1-6,12-17}-{1}-{RX,TX}

The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (4Ch) unit.


25.1.4  BANDWL

Band wavelength. Identifies a wavelength channel included in any of the lower layer OMS facilities.

Table 25-5 BANDWL 

Pattern
Description

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

Identifies an allocated wavelength channel included in any of the lower layer OMS facilities.

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

Identifies all of the allocated wavelength channels included in any of the lower layer OMS facilities.

BANDWL-[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-<WLEN>

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies.

Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in.

The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)]

BANDWL-[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies.

Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in.

The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)]


25.1.5  BITS

AID for building integrated timing supply (BITS).

Table 25-6 BITS 

Pattern
Description

ALL

The ALL AID is applicable to RTRV commands only (RTRV-BITS and RTRV-ALM/COND-BITS). The All AID is equivalent to BITS-ALL for these commands. For RTRV-ALM/COND-SYNCN, the ALL AID translates to BITS-ALL, SYNC-BITS1, and SYNC-BITS2

BITS-ALL

BITS AIDs of both BITS-1 and BITS-2 in the RTRV-BITS command.

BITS[<SHELFID>]-ALL

BITS shelf ID of both BITS-1 and BITS-2 in the RTRV-BITS command.

BITS[<SHELFID>]-{1,2}

Individual BITS AID.

SYNC[<SHELFID>]-BITS{1,2}

BITS-OUT AIDs of BITS-1 and BITS-2. These AIDs are applicable only in ED/RTRV-BITS commands and are used for setting and retrieving the BITS-OUT parameters.


25.1.6  CHANNEL

Accesses the Optical Channels (OCH) layer of Optical Networking/Client units.

Table 25-7 CHANNEL 

CHANNEL Values
Description

ALL

ALL OCHs of the NE. The ALL AID is applicable for retrieve-only commands

CHAN[-{1-8}]-{1-6,12-17}-ALL

All the channels of an Optical Transponder/Muxponder. The format is CHAN-[SLOT]-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-32}-
ALL

All the channels in an Optical Multiplexer/Demultiplexer (32Ch) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-32}-
{RX,TX}

The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (32Ch) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION]

CHAN[-{1-8}]-{1-6,12-17}-{1-32}-
{RX,PT}

The Receive/Passthrough channels in an Optical WSS (32Ch) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION]

CHAN[-{1-8}]-{1-6,12-17}-{1-4}-ALL

All the channels in an OADM (1Ch, 2Ch, 4Ch) unit and Optical and Optical Multiplexer/Demultiplexer (4Ch) unit. The format is CHAN-[SLOT]-[PORT]-ALL

CHAN[-{1-8}]-{1-6,12-17}-{1-4}-
{RX,TX}

The Receive/Transmit Channels in an OADM (1Ch, 2Ch, 4Ch) unit and Optical Multiplexer/Demultiplexer (4Ch) unit. The format is CHAN-[SLOT]-[PORT]-[DIRECTION]

CHAN[-{1-8}]-{1-6,12-17}-{2,3}

A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G and TXP_MR_2.5G use CHAN-slot-2 for the 1 DWDM Facility. TXPP_MR_2.5G uses CHAN-[SLOT]-{2,3} for the two DWDM facilities. The format is CHAN-[SLOT]-[PORT]

CHAN[-{1-8}]-{1-6,12-17}-{5}}

A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G uses CHAN-[SLOT]-2 for the 1 DWDM facility. MXP_2.5G_10G uses the CHAN-slot-5 for the 1 DWDM facility. The format is CHAN-[SLOT]-[PORT]

CHAN[-{1-8}]-{1-6,12-17}-{9,10}

A single channel of an Optical Muxponder. The MXP_MR_10DME_C and MXP_2.5G_10G use CHAN-[SHELF]-SLOT-9 for the 1 DWDM Facility. The MXPP_2.5G_10G uses CHAN-[SHELF]-SLOT-{9,10} for the 2 DWDM Facilities. The format is CHAN-[SHELF]-[SLOT]-[PORT]


25.1.7  COM

Common

Table 25-8 COM 

Pattern
Description

COM

Common


25.1.8  CrossConnectId

Table 25-9 CrossConnectId 

AID
Pattern

FACILITY

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,
30,32,34,36}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-12}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

VFAC-{1,2,5,6}-{1-8}

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}

25.1.9  CrossConnectId1

Table 25-10 CrossConnectId1 

AID
Pattern

VCM

VCM-{1-6,12-17}-{0-1}-ALL

VCM-{1-6,12-17}-{0-1}-{1-256}

VCM-{1-6,12-17}-{1-4}-ALL

VCM-{1-6,12-17}-{1-4}-{1-256}

FACILITY

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,
30,32,34,36}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-12}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

VFAC-{1,2,5,6}-{1-8}

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}

VC

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-1-{1-7}-{1-2}

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC (continued)

VC3-{1-6,12-17}-{1-4}-{1-3}

VC4-{1-4,11-14}-{1-16}-1

VC4-{1-4,11-14}-{1-16}-{1,5,9,13}

VC4-{1-4,11-14}-{1-16}-{1,9}

VC4-{1-4,11-14}-{1-4}-1

VC4-{1-4,11-14}-{1-4}-{1,17,33,49}

VC4-{1-4,11-14}-{1-4}-{1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61}

VC4-{1-4,11-14}-{1-4}-{1,9,17,25,33,41,49,57}

VC4-{1-4,11-14}-{1-4}-{1-64}

VC4-{1-4,14-17}-1

VC4-{1-4,14-17}-1-1

VC4-{1-4,14-17}-{1-12}-1

VC4-{1-4,14-17}-{1-4}-1

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4-{1-4,14-17}-{1-8}-1

VC4-{1-6,12-17}-1

VC4-{1-6,12-17}-1-1

VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-{1-6,12-17}-1-{1-16}

VC4-{1-6,12-17}-1-{1-2}

VC4-{1-6,12-17}-1-{1-3}

VC4-{1-6,12-17}-1-{1-4}

VC4-{1-6,12-17}-1-{1-9}

VC4-{1-6,12-17}-{1-4}

VC4-{1-6,12-17}-{1-4}-1


25.1.10  ENV

The environmental AID for the AIC-I cards

Table 25-11 ENV 

Pattern
Description

ALL

The ALL AID applies to retrieve-only commands: RTRV-ALM/COND-ENV, RTRV-ATTR-CONT, and RTRV-ATTR-ENV

ENV-IN-ALL

Environmental AID for ALL environmental alarms

ENV-IN[-{1-8}]-ALL

Environmental AID for ALL multishelf environmental alarms

ENV-IN[-{1-8}]-{1-4}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms

ENV-IN[-{1-8}]-{1-20}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms

ENV-IN[-{1-8}]-{1-32}

Environmental AID for AIC-I card extensions. "IN" is used for environmental alarms

ENV-IN[-{1-8}]-{1-3}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms

ENV-IN[-{1-8}]-{1-6}

Environmental AID. "IN" is used for environmental alarms

ENV-OUT-ALL

Environmental AID for AIC-I cards. "OUT" is used for environmental controls

ENV-OUT[-{1-8}]-ALL

Environmental AID for AIC-I cards. "OUT" is used for environmental controls

ENV-OUT[-{1-8}]-{1-4}

Environmental AID for AIC-I cards. "OUT" is used for environmental controls

ENV-OUT[-{1-8}]-{1-16}

Environmental AID for AIC-I card extensions. "OUT" is used for environmental controls

ENV-OUT[-{1-8}]-{1-2}

Environmental AID for AIC-I cards. "OUT" is used for environmental controls

ENV-{IN,OUT}[-{1-8}]-{1-16}

ENV-IN[1-16} is used for the environmental alarm AID. ENV-OUT-{1-16} is used for the external control AID


25.1.11  EQPT

Equipment AIDs are used to access specific cards.

Table 25-12 EQPT 

Pattern
Description

AIP-[-{1-8}]

The AID for the alarm interface panel (AIP). It is used for RTRV-INV output only.

AIP-ALL

The AID for all of the AIPs in any shelf of the node. It is used for RTRV-INV output only.

ALL

Only used for RTRV-INV, RTRV-EQPT, and RTRV-ALM/COND-EQPT commands. RTRV-INV returns all the inventory information for the NE. The ONS 15454 includes the multiservice cards, common control cards, and the AIP, BP, and FAN. The ONS 15327 includes the multiservice cards and common control cards. RTRV-EQPT with ALL AID returns EQPT information on all the slots. RTRV-ALM/COND-EQPT with ALL AID returns EQPT and PWR-A and PWR-B type of alarms and conditions.

BIC-ALL

AIDs for the backplane interface connectors (BICs), BIC-A and BIC-B. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BIC-[-{1-8}]-ALL

AIDs for the backplane interface connectors (BICs), BIC-A and BIC-B of a single shelf in a multishelf node. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BIC[-{1-8}]-{A,B}

AIDs for the BICs. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BP[-{1-8}]

The AID for the backplane. It is used for RTRV-INV output only.

BP-ALL

The AID for all of the backplanes in any shelf on the multishelf node. It is used for RTRV-INV output only.

FAN[-{1-8}]

The AID for the fan tray. It is used for RTRV-INV output only.

FAN-ALL

The AID for all of the fan tray in all the shelves of a multishelf node. It is used for RTRV-INV output only.

PPM-{1-6,12-17}-1

PPM for the OC192-XFP card. Format is PPM-[SLOT]-[PPM].

PPM-{1-6,12-17}-{1-12}

PPM for the MRC-12 card. Format is PPM-[SLOT]-[PPM].

PPM[-{1-8}]-{1-6,12-17}-
{1-4}

PPM AID for dense wavelength division multiplexing (DWDM) MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_10E cards. Format of AID is PPM-[SLOT]-[PPM].

PPM[-{1-8}]-{1-6,12-17}-
{1-8}

(ONS 15454 only) PPM AID for the MXP_MR_2.5G and MXPP_MR_2.5G cards. Format of AID is PPM-[SLOT]-[PPM].

PWR-ALL

AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

PWR[-{1-8}]-{A,B}

AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

PWR[-{1-8}]-ALL

AIDs for all of the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

SLOT-ALL

All of the NE equipment AIDs.

SLOT[-{1-8}]-{1-17}

EQPT AID where the format is SLOT-[SLOT].

SLOT[-{1-8}]-{1-6,12-17}

Individual equipment AID of the multiservice card units or slots where the format is SLOT-[SLOT].


25.1.12  FACILITY

Facilities AIDs are used to access specific ports.

Facility AID format:

Format for DS3i-N-12 electrical facilities: FAC-[SLOT]-[PORT]

Format for POS ports: VFAC-[SLOT]-[PORT]

Format for POS port with PIM and PPM: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]

Table 25-13 FACILITY 

Pattern
Description

ALL

The ALL AID is applicable for RTRV-only commands (RTRV-rr type of commands), for example: RTRV-STM16 with an ALL AID returns all STM16 facilities on the node

FAC[-{1-8}]-{1-4,14-17}-{1-8}

Facilities for an STM1 card where the format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{1-6,12-17}-1

Facility AID for the 1 Client (CLNT) port on a TXP_MR_10G, TXP_MR_2.5G, TXP_MR_2.5G or TXPP_MR_2.5G card where the format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{1-6,12-17}-ALL

All the facilities of an I/O unit or slot where the format is FAC-[SLOT]-[ALL]

FAC[-{1-8}]-{1-6,12-17}-{0-11}

Facilities for the Ethernet front-end ports on the ML100T-12 card. Ports are numbered starting with 0 (that is, the first port is FAC-SLOT-0, second port is FAC-SLOT-1, ..., last port is FAC-SLOT-11 for ML100T-12, first port is FAC-SLOT-0 and second port is FAC-SLOT-1 for ML1000-2). The format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{1-6,12-17}-{0-1}

Facilities for the Ethernet back-end Ports on the ML1000-2 card. Ports are 0-based, (for example, the first port is FAC-SLOT-0 and the second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT]

FAC-{1-6,12-17}-{1-8}

Facility AID for the Ethernet front-end ports on the CE-100T-8 card The format is FAC-[SLOT]-[PORT].

FAC-{1-6,12-17}-{0-11}

Facility AID for the Ethernet front-end ports on the MS-ISC-100T The first port is FAC-SLOT-0, the second port is FAC-SLOT-1, and so on. The last port is FAC-SLOT-11. The format is FAC-[SLOT]-[PORT].

FAC[-{1-8}]-{1-6,12-17}-{1-12,14,16,18,
20,22,24,26,28,30,32,34,36}

Facility AIDs for the DS3i-N-12 VC416 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available

FAC[-{1-8}]-{1-6,12-17}-{1-12,14,16,18,
20,22,24}

Facility AIDs for DS3i-N-12 VC44 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available

FAC[-{1-8}]-{1-6,12-17}-{1-4}

Facility AID for the four Client (CLNT) facilities on the MXP_2.5G_10G card. Facility AID for 4-Port G1000/FC_MR-4 card. Facility AID for creating/editing cross-connects (VC3, VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C) for the 4-Port G1000/FC_MR-4 card where format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{1-6,12-17}-{1-6}

Facilities for the DS3i-N-12 card where the format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{1-6,12-17}-{1}

Facility AID for the 1-Port STM4, STM16, and STM1 in OSC-CSM cards. Facility AID for the client ports on the MXP/TXP and TXP_MR_2.5G cards where format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{5,6,12,13}-{1}

Facility AID for the STM16/STM64 cards. The STM16/STM64 cards can only use Slot 5, Slot 6, Slot 12, and Slot 13 where format is FAC-[SLOT]-[PORT]

FAC[-{1-8}]-{8,10}-{1}

Facility AID for the OSCM card. The OSCM cards can only use the XC10G slots (Slot 8, Slot 10) where format is FAC-[SLOT]-[PORT]

VFAC[-{1-8}]-{1-6,12-17}-{0-1}

Facilities for the back-end POS ports on the ML-Series card. Port numbering is 0-based (first POS port is VFAC-SLOT-0, second POS port is VFAC-SLOT-1). VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C for the ML1000 and ML100T cards. Format is VFAC-[SLOT]-[PORT]

VFAC[-{1-8}]-{1-6,12-17}-{1,2}

GFP facilities on the MXP-MR-2.5G and MXPP-MR-2.5G cards

VFAC[-{1-8}]-{1-6,12-17}-{1,2}
-{1,8}

GFP Client facilities for MXP-MR-2.5G and MXPP-MR-2.5G cards

FAC[-{1-30}]-{1-4,14-17}-{1-4}

Facility AID for four Ether Ports on the CE1000 card.

VFAC[-{1-30}]-{1-4,14-17}-{1-4}

Facility AID for the back-end ports on the CE1000 card.


25.1.13  IPADDR

IP Address

Table 25-14 IPADDR 

Pattern
Description

111.222.333.444

Standard 4 Part IP Address Notation

ALL

ALL


25.1.14  LINE

The LINE AID is used to access the Optical Transport Section (OTS) layer of optical networking units. Applicable only to ONS 15454 SDH AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION].

Table 25-15 LINE 

Values
Description

ALL

All of the OTSs of the NE. The ALL AID applies to retrieve-only commands

LINE-{1-6,12-17}-{1-2}-ALL

All the lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, and AD-4C units

LINE-{1-6,12-17}-{1-2}-{RX,TX}

The receive/transmit Lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, and AD-4C units

LINE-{1-6,12-17}-{1-3}-{RX,TX}

The receive/transmit lines in a OPT-BST units

LINE-{8,10}-{1}-ALL

All the lines in a OSCM units

LINE-{8,10}-{1}-{RX,TX}

The receive/transmit lines in OSCM units

LINE-[{1-8}-]{1-6,12-17}-{1}-
{RX,TX}

For Booster units, there is an input OTS for LINE(1) and an output OTS (Amplified) for amplification stage COM(2), 2 OTS for input line COM(2) and output LINE(1) and 2 OTS for OSC(3) Add & Drop service channel.

LINE-[{1-8}-]{1-6,12-17}-{2}-
{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{3}-
{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{1-3}-ALL

LINE-[{1-8}-]{1-6,12-17}-{1}-
{RX,TX}

Pre-Amplifier unit with 2 stages of amplification; input OTS for LINE(1) and an output OTS (Amplified) for amplification stage COM(2), 2 OTS for input line COM(2) and output LINE(1) and 2 OTS for OSC(3) Add & Drop service channel and output and an input OTS for the DCU(2).

LINE-[{1-8}-]{1-6,12-17}-{2}-
{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{3}-
{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{4}-
{RX,TX}

LINE-[{1-8}-]{1-6,12-17}-{1-4}-ALL

LINE-[{1-8}-]{1-6,12-17}-1-RX
For input OTS

For demux units there is an OTS for input line, and up to 32 OCH for drop channel connectors. Demux is a unidirectional unit.

LINE-[{1-8}-]{1-6,12-17}-1-ALL

CHAN-[{1-8}-]{1-6,12-17}-{1-32}-TXFor Drop OCH

CHAN-[{1-8}-]{1-6,12-17}-{1-32}-
ALL

LINE-[{1-8}-]{1-5,12-16}-{1}-
{RX,TX} (EXP)

Wavelength switch selector unit has input and output OTS for signal coming from amplifier units COM(2), input and output OTS for signal continuing to next WSS unit in the node EXP(1) and an output PT(3) drop port for the signal continuing to 32-DMX-L card. It also has 32 internal OCH pass-through channels (PT) and 32 external input channels (ADD). This unit is 2 slots sized.

LINE-[{1-8}-]{1-5,12-16}-{2}-
{RX,TX} (COM)

LINE-[{1-8}-]{1-5,12-16}-{3}-{TX} (DROP)

LINE-[{1-8}-]{1-5,12-16}-{1-3}-ALL

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-
{RX} (ADD)

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-
{PT} (PT)

CHAN-[{1-8}-]{1-5,12-16}-{1-32}-
ALL

LINE-[{1-8}-]{1-6,12-17}-{1}-
{RX,TX} (EXP)

Multiring/mesh unit has 6 OTS connectors: 2 are the input and output OTS for signal coming from amplifier units COM(1), the other are for the split 50/50 signal continuing to AD, MUX/DEMUX, WSS unit. Because the incoming signal is split into 2 separate signals, there are two sets of input and output EXP port (2 and 3).

LINE-[{1-8}-]{1-6,12-17}-{2}-
{RX,TX} (COM)

LINE-[{1-8}-]{1-6,12-17}-{3}-
{RX,TX} (EXP to other ring)

LINE-[{1-8}-]{1-6,12-17}-{1-3}-ALL


25.1.15  LINEWL

Line wavelength. Identifies a wavelength channel included in any of the lower layer OTS facilities.

Table 25-16 LINEWL 

Values
Description

LINEWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

Identifies an allocated wavelength channel included in any of the lower layer OTS facilities.

LINEWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

Identifies all of the allocated wavelength channels included in any of the lower layer OTS facilities.

LINEWL-[{1-8}-]{1-6,12-17}-{1-32}-
{RX,TX,PT}-<WLEN>

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies.

Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in.

The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)].

LINEWL -[{1-8}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies.

Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in.

The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)].


25.1.16  LNKTERM

Link Termination AIDs that are used to access the termination points of a provisionable patchcord.

Table 25-17 LNKTERM 

Pattern
Description

ALL

Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands

LNKTERM-ALL

Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands

LNKTERM-{1-65535}

Indicates a single provisionable patchcord termination point on a node


25.1.17  MSSPR

MS-SPRing AIDs are used to access the MS-SPRing of the NE.

Table 25-18 MSSPR 

Pattern
Description

ALL

ALL AID for all MS-SPRings in the NE. The ALL AID is applicable for retrieve-only commands like RTRV-MSSPR and RTRV-ALM/COND-MSSPR

MSSPR-RINGID

MS-SPRing AID is keyword MS-SPRing followed by RINGID. RINGID is a string of up to 6 characters; valid characters are [A-Z,0-9] (case insensitive)


25.1.18  OPM

OPM AIDs represent the single wavelength inside an optical power monitoring object

Table 25-19 OPM

Values
Description

ALL

The first ID represents the shelf, the second ID represents the slot, and the last ID is the wavelength, represented in the form of 15xx.yy nanometers. The last index of the wavelength is the value of the wavelength as described in OPTICAL_WLEN.

OPM[-{1-8}]-{1-5,12-16}-ALL

OPM[-{1-8}]-{1-5,12-16}-<wlen>


25.1.19  OSC

OSC AIDs are used to access the OSC of the NE

Table 25-20 OSC 

Values
Description

ALL

All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands

OSC-RINGID

RINGID is a string of up to six characters, valid characters are [A-Z,0-9] (case insensitive)


25.1.20  PRSLOT

Valid protection slots for the electrical cards. Format is SLOT-[SLOT].

Table 25-21 PRSLOT 

Pattern
Description

NULL

Indicates there is no protection group. Used when trying to delete a protection group.

SLOT-1

The No. 1 slot of an NE

SLOT-3

The No. 3 slot of an NE

SLOT-5

The No. 5 slot of an NE

SLOT-13

The No. 13 slot of an NE

SLOT-15

The No. 15 slot of an NE

SLOT-17

The No. 17 slot of an NE


25.1.21  RFILE

File transfer type.

Table 25-22 RFILE

Pattern
Description

RFILE-DB

Transferring the provisioning database.

RFILE-LOG

Transferring a log file

RFILE-PKG

Transferring a software package

RFILE-COMPDB

Transferring the provisioning and system database


25.1.22  SHELF

Identifies a shelf within a node. SHELF is applicable only to nodes that are set to MULTISHELF or MULTISHELFETH mode.

Table 25-23 SHELF

Pattern
Description

SHELF-ALL

All of the shelves in the node.

SHELF-{1-8}

A specific shelf in the node.


25.1.23  SYN

Synchronization AIDs

Table 25-24 SYN 

Pattern
Description

SYNC-NE

NE synchronization AID


25.1.24  SYN_SRC

Synchronization source

Table 25-25 SYN_SRC 

Pattern
Description

BITS-1

Synchronization source is BITS-1. Format is BITS-[PORT]

BITS-2

Synchronization source is BITS-2. Format is BITS-[PORT]

FAC-{1-4,11-14}-{1-4}

Synchronization source is 4-Port STM64. Format is FAC-[SLOT]-[PORT]

FAC-{1-6,12-17}-{1-4}

Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT]

FAC-{1-6,12-17}-{1}

Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT]

FAC-{5,6,12,13}-{1}

Synchronization source is the optical card (STM16 and STM 64) facility. Format is FAC-[SLOT]-[PORT]

INTERNAL

Set the SYN_SRC to be the system default value. The "Internal" value of the SYN_SRC is only applied for the SYNC-NE AID on the ED-SYNCN command

NONE

Set the SYNC_SRC value to the default value for BITS-OUT. The "NONE" value of SYNC_SRC only applies to the BITS-1 and BITS-2 AID of the ED-SYNCN command

SYNC-NE

SYNC-NE source. It is only used in the alarm report or alarm retrieve commands.


25.1.25  SYNC_REF

Synchronization AIDs

Facility AID format for line timing:

Format for optical facilities without PPM: FAC-[SLOT]-[PORT]

Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]

Table 25-26 SYNC_REF 

Pattern
Description

ALL

Equivalent to a combination of SYNC-ALL, BITS-1, and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN, and RTRV-COND-SYNCN

SYNC-ALL

All synchronization references

SYNC-{1-30}-NE

NE synchronization AID

SYNC-{1-30}-{BITS1,BITS2}

BITS1 and BITS2 sync AIDs


25.1.26  SYNCSW

Synchronization reference

Table 25-27 SYNCSW 

Pattern
Description

INT

Internal clock. The "INT" value of the SYNCSW is only applied for the SYNC-NE AID on the OPR-SYNCSW command.

PRI

Primary timing reference

SEC

Secondary timing reference


25.1.27  UDC

UDC AIDs for F-UDC and DCC-UDC channels on the AIC-I card.

Table 25-28 UDC 

Pattern
Description

ALL

ALL AID is applicable to retrieve-only commands, for example: RTRV-ALM/COND-UDCF and RTRV-ALM/COND-UDCDCC. It corresponds to a superset of F-UDC and DCC-UDC AIDs

UDC-{F,DCC}-{A,B}

F-UDC and DCC-UDC AIDs for A and B channels


25.1.28  VC

SDH Frame Level AID Set.

VC4 AID Formats

For Optical Facilities: VC4-[SLOT]-[PORT]-[VC4]

For Electrical Facilities: VC4-[SLOT]-[VC4]

VC3 AID Formats

For Optical Facilities: VC3-[SLOT]-[PORT]-[VC4]-[VC3]

For Electrical Facilities: VC3-[SLOT]-[VC4]-[VC3]

VC12 AID Formats

For Optical Facilities: VC12-[SLOT]-[PORT]-[VC4]-[VC3]-[TUG2]-[VC12]

For Electrical Facilities: VC12-[SLOT]-[VC4]-[VC3]-[TUG2]-[VC12]

VC11 AID Formats

For Optical Facilities: VC11-[SLOT]-[PORT]-[VC4]-[VC3]-[TUG2]-[VC11]

For Electrical Facilities: VC11-[SLOT]-[VC4]-[VC3]-[TUG2]-[VC11]

Table 25-29 VC 

Pattern
Description

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11 for the STM1E-12 card

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11 for STM4-4

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11 for STM1-8 card

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11 for STM-16 card

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11 for STM-4 card

VC11-{1-6,12-17}-{1-14}-1-11{1-7}-{1-2}

VC11 for the E1 card

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC11 for the STM-1 card

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12 for the STM1E-12 card

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12 for STM4-4 card

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12 for STM1-8 card

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12 AIDs for the E1 card

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12 for STM-16 card

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12 for E1-42 card

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12 for STM-4 card

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC12 for STM-1 card

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3 for the STM1E-12 card

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3 for the STM4-4 card

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3 for the STM1-8 card

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3 for the STM-16 card

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3 for the STM-4 card

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3 for the STM-1 card

VC3-{1-6,12-17}-{1-4}-{1-3}

VC3 AID for DS3i-N-12 and E3 card

VC4-{1-4,14-17}-1

VC4 for E1-42 card

VC4-{1-4,14-17}-1-1

VC4 for STM1-8 card

VC4-{1-4,14-17}-{1-12}-1

VC4 for the STM1E-12 card

VC4-{1-4,14-17}-{1-4}-1

VC4 for the STM4 card and VC4-4c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-3c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-2c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4 for the STM4-4 card

VC4-{1-4,14-17}-{1-8}-1

VC4 for the STM1-8 card

VC4-{1-6,12-17}-1

VC4 for E1 card

VC4-{1-6,12-17}-1-1

VC4-4c for the STM-4 card. VC4-16c for the STM-16 card

VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-2c for the STM-16 card

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-3c for the STM-16

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-4c for the STM-16 card

VC4-{1-6,12-17}-1-{1-16}

VC4 for the STM-16 card

VC4-{1-6,12-17}-1-{1-2}

VC4-3c for the STM-4 card

VC4-{1-6,12-17}-1-{1-3}

VC4-2c for the STM-4 card

VC4-{1-6,12-17}-1-{1-4}

VC4 for the STM-4 card

VC4-{1-6,12-17}-1-{1-9}

VC4-8c for the STM-16 card (454)

VC4-{1-6,12-17}-{1-4}

VC4 for DS3i-N-12, E3, G1000 cards

VC4-{1-6,12-17}-{1-4}-1

VC4 for STM-1 card


25.1.29  WDMANS

This AID is used to access the automatic optical node set up (AONS) application of the NE.

Table 25-30 WDMANS 

Pattern
Description

AONS-{E,W}

Automatic Optical Node Setup identifier (per ring direction based)

WDMANS-{E,W}

Automatic Optical Node Setup identifier (per ring direction based)


25.1.30  WLEN

This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line) the wavelengths contained are all the available in the node: currently 32. If the facility is of type OCH (CHAN) the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.

Table 25-31 WLEN 

Pattern
Description

WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90,
1532.68,1534.25,1535.04,1535.82,1536.61,1538.19,1538.98,1539.77,
1540.56,1542.14,1542.94,1543.73,1544.53,1546.12,1546.92,,1547.72,
1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,1554.94,
1555.75,1556.55,1558.17,1558.98,1559.79,1560.61}

Wavelength identifier


25.2  CTC Port Numbers and TL1 Aids

Table 25-32 CTC Port Numbers and TL1 Aids

Equipment
CTC Port Name
CTC Port Number
TL1 Aid

OSC-CSM

COM-RX

2

LINE-shelf-slot-1-RX

COM-TX

3

LINE-shelf-slot-1-TX

LINE-RX

4

LINE-shelf-slot-2-RX

LINE-TX

5

LINE-shelf-slot-2-TX

OSC-RX

6

LINE-shelf-slot-3-RX

OSC-TX

7

LINE-shelf-slot-3-TX

OC3

1

FAC-shelf-slot-1

32 DMX

CHAN TX

1-32

CHAN-shelf-slot-i-TX (i=1..32)

COM-RX

33

LINE-shelf-slot-1-RX

OPT-PRE

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

DC-RX

3

LINE-shelf-slot-2-RX

DC-TX

4

LINE-shelf-slot-2-TX

4 MD

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

CHAN-RX

5

CHAN-shelf-slot-3-RX

CHAN-TX

6

CHAN-shelf-slot-3-TX

CHAN-RX

7

CHAN-shelf-slot-4-RX

CHAN-TX

8

CHAN-shelf-slot-4-TX

COM-RX

9

LINE-shelf-slot-1-RX

COM-TX

10

LINE-shelf-slot-1-TX

32 DMX L

CHAN TX

1 - 32

CHAN-shelf-slot-i-TX (i=1..32)

COM RX

33

LINE-shelf-slot-1-RX

32 WSS L

ADD-RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

PT

33-64

CHAN-shelf-slot-i-PT (i=1..32)

DROP-TX

69

LINE-shelf-slot-3-TX

EXP-RX

66

LINE-shelf-slot-2-RX

EXP-TX

65

LINE-shelf-slot-2-TX

COM-RX

68

LINE-shelf-slot-1-RX

COM-TX

67

LINE-shelf-slot-1-TX

OPT-BST

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-BST E

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-BST L

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-2-TX

OSC-RX

3

LINE-shelf-slot-1-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-1-RX

LINE-TX

6

LINE-shelf-slot-2-TX

MMU

EXPA-RX

5

LINE-shelf-slot-3-RX

EXPA-TX

6

LINE-shelf-slot-3-TX

EXP-RX

1

LINE-shelf-slot-1-RX

EXP-TX

2

LINE-shelf-slot-1-TX

COM-RX

3

LINE-shelf-slot-2-RX

COM-TX

4

LINE-shelf-slot-2-TX

AD 1B

BAND-RX

1

BAND-shelf-slot-1-RX

BAND-TX

2

BAND-shelf-slot-1-TX

EXP-RX

3

LINE-shelf-slot-1-RX

EXP-TX

4

LINE-shelf-slot-1-TX

COM-RX

5

LINE-shelf-slot-2-RX

COM-TX

6

LINE-shelf-slot-2-TX

AD 1C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

EXP-RX

3

LINE-shelf-slot-1-RX

EXP-TX

4

LINE-shelf-slot-1-TX

COM-RX

5

LINE-shelf-slot-2-RX

COM-TX

6

LINE-shelf-slot-2-TX

AD 2C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

EXP-RX

5

LINE-shelf-slot-1-RX

EXP-TX

6

LINE-shelf-slot-1-TX

COM-RX

7

LINE-shelf-slot-2-RX

COM-TX

8

LINE-shelf-slot-2-TX

AD 4C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

CHAN-RX

5

CHAN-shelf-slot-3-RX

CHAN-TX

6

CHAN-shelf-slot-3-TX

CHAN-RX

7

CHAN-shelf-slot-4-RX

CHAN-TX

8

CHAN-shelf-slot-4-TX

EXP-RX

9

LINE-shelf-slot-1-RX

EXP-TX

10

LINE-shelf-slot-1-TX

COM-RX

11

LINE-shelf-slot-2-RX

COM-TX

12

LINE-shelf-slot-2-TX

32 WSS

ADD-RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

PT

33-64

CHAN-shelf-slot-i-PT (i=1..32)

DROP-TX

69

LINE-shelf-slot-3-TX

EXP-RX

66

LINE-shelf-slot-2-RX

RXP-TX

65

LINE-shelf-slot-2-TX

COM-RX

68

LINE-shelf-slot-1-RX

COM-TX

67

LINE-shelf-slot-1-TX

32 DMXO

CHAN-TX

1-32

CHAN-shelf-slot-i-TX (i=1..32)

COM-RX

33

LINE-shelf-slot-1-RX

32 MUXO

CHAN RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

COM TX

33

LINE-shelf-slot-1-TX