Cisco ONS 15454 SDH Procedure Guide, Release 4.0
Chapter 6, Create Circuits and VT Tunnels
Downloads: This chapterpdf (PDF - 1.39MB) The complete bookPDF (PDF - 9.09MB) | Feedback

Create Circuits and Low-Order Tunnels

Table Of Contents

Create Circuits and Low-Order Tunnels

Before You Begin

NTP-D127 Verify Network Turn Up

NTP-D81 Create an Automatically Routed Low-Order VC12 Circuit

NTP-D82 Create a Manually Routed Low-Order VC12 Circuit

NTP-D83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops

DLP-D317 Verify XCVXL Card Installation

DLP-D314 Assign a Name to a Port

DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination

DLP-D96 Provision a Low-Order VC12 Circuit Route

NTP-D54 Create an Automatically Routed Low-Order VC3 Circuit

NTP-D55 Create a Manually Routed Low-Order VC3 Circuit

NTP-D56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

DLP-D218 Provision SNCP Ring Selectors During Circuit Creation

DLP-D218 Provision a Low-Order VC3 Circuit Source and Destination

DLP-D96 Provision a Low-Order VC3 Circuit Route

NTP-D133 Create an Automatically Routed Low-Order Tunnel

NTP-D134 Create a Manually Routed Low-Order Tunnel

DLP-D219 Provision a Low-Order Tunnel Route

NTP-D216 Create a Low-Order Path Tunnel for Port Grouping

NTP-D187 Create a Low-Order Aggregation Point

NTP-D135 Test Low-Order Circuits

NTP-D188 Create an Automatically Routed High-Order Circuit

NTP-D189 Create a Manually Routed High-Order Circuit

NTP-D190 Create a Unidirectional High-Order Circuit with Multiple Drops

DLP-D97 Provision a High-Order Circuit Source and Destination

DLP-D98 Provision a High-Order Circuit Route

NTP-D62 Test High-Order Circuits

NTP-D139 Create a Half Circuit on an MS-SPRing or 1+1 Node

NTP-D140 Create a Half Circuit on an SNCP ring Node

DLP-D311 Provision a Half Circuit Source and Destination - MS-SPRing and 1+1

DLP-D312 Provision a Half Circuit Source and Destination - SNCP Ring

NTP-D191 Create an E-Series EtherSwitch Circuit (Multicard or Single-Card Mode)

NTP-D192 Create a Circuit for an E-Series Card in Port-Mapped Mode

NTP-D142 Create an E-Series Shared Packet Ring Ethernet Circuit

NTP-D143 Create an E-Series Hub and Spoke Ethernet Configuration

NTP-D144 Create an E-Series Single-Card EtherSwitch Manual Cross-Connect

NTP-D145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect

DLP-D99 Determine Available VLANs

DLP-D246 Provision E-Series Ethernet Card Mode

DLP-D220 Provision E-Series Ethernet Ports

DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership

NTP-D146 Test E-Series Circuits

NTP-D147 Create a G-Series Circuit

NTP-D148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode

DLP-D222 Provision G-Series Ethernet Ports

NTP-D149 Test G-Series or ML-Series Circuits

NTP-D193 Create an ML-Series Circuit

NTP-D194 Create Overhead Circuits

DLP-D313 Create a DCC Tunnel

DLP-D83 Provision Orderwire

DLP-D212 Create a User Data Channel Circuit


Create Circuits and Low-Order Tunnels


This chapter explains how to create Cisco ONS 15454 SDH low-order circuits and tunnels, high-order circuits, and Ethernet circuits. For additional information about ONS 15454 SDH circuits, refer to the Circuits and Tunnels chapter in the Cisco ONS 15454 SDH Reference Manual.

Before You Begin

Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide as necessary.

This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).

1. 127 Verify Network Turn Up—Complete this procedure before you create any circuits.

2. 81 Create an Automatically Routed Low-Order VC12 Circuit—Complete as needed.

3. 82 Create a Manually Routed Low-Order VC12 Circuit—Complete as needed.

4. 83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops—Complete as needed.

5. 54 Create an Automatically Routed Low-Order VC3 Circuit—Complete as needed.

6. 55 Create a Manually Routed Low-Order VC3 Circuit—Complete as needed.

7. 56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops—Complete as needed.

8. 133 Create an Automatically Routed Low-Order Tunnel—Complete as needed.

9. 134 Create a Manually Routed Low-Order Tunnel—Complete as needed.

10. 216 Create a Low-Order Path Tunnel for Port Grouping—Complete as needed.

11. 187 Create a Low-Order Aggregation Point—Complete as needed.

12. 135 Test Low-Order Circuits—Complete this procedure after you create an electrical circuit.

13. 188 Create an Automatically Routed High-Order Circuit—Complete as needed.

14. 189 Create a Manually Routed High-Order Circuit—Complete as needed.

15. 190 Create a Unidirectional High-Order Circuit with Multiple Drops—Complete as needed.

16. 62 Test High-Order Circuits—Complete this procedure after you create a high-order optical circuit.

17. 139 Create a Half Circuit on an MS-SPRing or 1+1 Node—Complete this procedure as needed to create a half circuit using an STM-N as a destination in an MS-SPRing or 1+1.

18. 140 Create a Half Circuit on an SNCP ring Node—Complete as needed to create a half circuit using an STM-N as a destination in an SNCP ring.

19. 191 Create an E-Series EtherSwitch Circuit (Multicard or Single-Card Mode)—Complete as needed.

20. 192 Create a Circuit for an E-Series Card in Port-Mapped Mode—Complete as needed.

21. 142 Create an E-Series Shared Packet Ring Ethernet Circuit—Complete as needed.

22. 143 Create an E-Series Hub and Spoke Ethernet Configuration—Complete as needed.

23. 144 Create an E-Series Single-Card EtherSwitch Manual Cross-Connect—Complete as needed.

24. 145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect—Complete as needed.

25. 146 Test E-Series Circuits—Complete after creating E-Series SDH circuits.

26. 147 Create a G-Series Circuit—Complete as needed.

27. 148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode—Complete as needed.

28. 149 Test G-Series or ML-Series Circuits—Complete after creating G-Series SDH circuits.

29. 193 Create an ML-Series Circuit—Complete as needed.

Table 6-1 defines ONS 15454 SDH circuit creation terms and options.

Table 6-1 ONS 15454 SDH Circuit Options 

Circuit Option
Description

Source

The circuit source is where the circuit enters the ONS 15454 SDH network.

Destination

The circuit destination is where the circuit exits an ONS 15454 SDH network.

Automatic circuit routing

CTC routes the circuit automatically on the shortest available path based on routing parameters and bandwidth availability.

Manual circuit routing

Manual routing allows you to choose a specific path, not just the shortest path chosen by automatic routing. You can choose a specific VC4, VC3, or VC12 for each circuit segment and create circuits from work orders prepared by an operations support system (OSS).

Low-order tunnel

Low-order tunnels allow VC3 and VC12 circuits to pass through an ONS 15454 SDH without using cross-connect card (XC10G and XCVXL) resources. Low-order- circuits using tunnels will use cross-connect capacity only at the source and destination nodes. One low-order tunnel can carry three VC3s, and each VC3 can carry 21 VC12s. One tunnel can carry one VC3 circuit span and 42 VC12 circuit spans, and each VC3 is a separate container that can contain a VC3 circuit span or 21 VC12 circuit spans.

Low-order Aggregation Point

Low-order aggregation points (LAPs) allow low-order VC12 and VC3 circuits to be aggregated into a VC4 to reduce cross-connect card low-order matrix resource utilization. The VC4 grooming end of the LAP requires an STM-N card.


ONS 15454 SDH circuits are either low-order or high-order circuits. Table 6-2 shows the circuit source and destination options for low-order circuits.

Table 6-2 CTC Circuit Source and Destination Options for Low-Order VC3 Circuits 

Card
Ports
VC4s
VC3s

E1-N-14

-

-

-

E1-42

-

-

-

E3-12

12

4 per port

3 per VC4

DS3i-N-12

12

4 per port

3 per VC4

STM1E-12

12

-

7 per port

OC3 IR 4/STM1

4

3 per port

3 per VC4

OC3 IR 4/STM1-8

8

3 per port

3 per VC4

OC12 IR/STM4 OC12 LR/STM4

1

4 per port

3 per VC4

OC12 IR 4/STM4 OC12 LR 4/STM4

4

4 per port

3 per VC4

All OC-48/STM16 cards

1

16 per port

3 per VC4

All OC-192/STM64 cards

1

64 per port

3 per VC4


Table 6-3 CTC Circuit Source and Destination Options for Low-Order VC12 Circuits 

Card
Ports
VC4s
TUG3s
TUG2s
VC12s

E1-N-14

14

-

-

7 per port

2 per TUG2

E1-42

42

-

2 per port

7 per TUG3

3 per TUG3

E3-12

-

-

-

-

-

DS3i-N-12

-

-

-

-

-

STM1E-12

12

-

7 per port

7 per TUG3

3 per TUG2

OC3 IR 4/STM1

4

3 per port

3 per VC4

7 per TUG3

3 per TUG2

OC3 IR 4/STM1-8

8

3 per port

3 per VC4

7 per TUG3

3 per TUG2

OC12 IR/STM4 OC12 LR/STM4

1

4 per port

3 per VC4

7 per TUG3

3 per TUG2

OC12 IR 4/STM4 OC12 LR 4/STM4

4

3 per port

3 per VC4

7 per TUG3

3 per TUG2

All OC-48/STM16 cards

1

16 per port

3 per VC4

7 per TUG3

3 per TUG2

OC-192/STM64

1

64 per port

3 per VC4

7 per TUG3

3 per TUG2


Table 6-4 shows the options that display for high-order circuits.

Table 6-4 CTC Circuit Source and Destination Options for High-Order VC4 Circuits

Card
Ports
VC4s

E1-N-14

-

-

E1-42

-

1

E3-12

12

4 per port

DS3i-N-12

12

4 per port

STM1E-12

12

-

OC3 IR 4/STM1

4

-

OC3 IR 4/STM1-8

8

3 per port

OC12 IR/STM4 OC12 LR/STM4

1

4

OC12 IR 4/STM4 OC12 LR 4/STM4

4

4 per port

All OC-48/STM16 cards

16

-

All OC-192/STM64 cards

64

-


NTP-D127 Verify Network Turn Up

Purpose

This procedure verifies that the ONS 15454 SDH network is ready for circuit provisioning.

Tools/Equipment

None

Prerequisite Procedures

Chapter 5, "Turn Up Network"

Required/As Needed

Required

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into an ONS 15454 SDH on the network where you will create circuits. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 From the View menu, choose Go to Network View. Wait for all the nodes that are part of the network to display on the network map. (Large networks may take several minutes to display all the nodes.)


Note If this is the first time your computer has connected to this ONS 15454 SDH network, the node icons will be stacked on the left side of the graphic area, possibly out of view. Use the scroll bar under the network map to display the icons. To separate the icons press Ctrl and drag and drop the icon to the new location. Repeat until all the nodes are visible on the graphic area.


Step 3 Verify node accessibility. In the network view, all node icons must be either green, yellow, orange, or red.

If all network nodes do not display after a few minutes, or if a node icon is grey with an IP address under it, do not continue. Look at the Net box in the lower right corner of the window. If it is grey, log in again, making sure not to check the Disable Network check box on the CTC Login dialog box. If problems persist, see Chapter 5, "Turn Up Network" to review the network turn-up procedure appropriate for your network topology, or refer to the Cisco ONS 15454 SDH Troubleshooting Guide for troubleshooting procedures.

Step 4 Verify DCC connectivity. All nodes must be connected by green lines. If lines are missing or grey in color, do not continue. See Chapter 5, "Turn Up Network" and follow the network turn-up procedure appropriate for your network topology. Verify that all nodes have DCC connectivity before continuing. If DCCs need to be created, complete the "DLP-D253 Provision SDH DCC Terminations" task on page 5-5.

Step 5 Click the Alarms tab to view alarm descriptions.Investigate and resolve, if necessary, all critical (red node icon) or major (orange node icon) alarms. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide to resolve alarms before continuing.

Step 6 From the View menu, choose Go to Home View. Verify that the node is provisioned according to your site or engineering plan:

a. View the cards displayed in the shelf map. Verify that the ONS 15454 SDH cards appear in the specified slots.

b. Click the Provisioning > General tabs. Verify that the node name, contacts, date, time, and NTP/SNTP server IP address (if used) are correctly provisioned. If needed, make corrections using the "DLP-D140 Change the Node Name, Date, Time, and Contact Information" task on page 10-2.

c. Click the Network tab. Verify that the IP address, Subnet mask, Default Router, Prevent LCD IP Config, and Gateway Settings are correctly provisioned. If not, make corrections using the "NTP-D201 Change CTC Network Access" procedure on page 10-4.

d. Click the Protection tab. Verify that protection groups are created as specified in your site plan. If the protection groups are not created, complete the "NTP-D203 Modify or Delete Card Protection Settings" procedure on page 10-12.

e. If the node is in an MS-SPRing, click the MS-SPRing tab. (If the node is not in an MS-SPRing, continue with Step f.) Verify that the following items are provisioned as specified in your site plan:

MS-SPRing type (2-Fiber or 4-Fiber)

MS-SPRing ring ID and node IDs

Ring reversion time

East and west card assignments

4-fiber MS-SPRings: span reversion and east/west protect card assignments

If you need to make corrections, see the "NTP-D40 Provision MS-SPRing Nodes" task on page 5-15 for instructions.

f. Click the Security tab. Verify that the users and access levels are provisioned as specified. If not, see the "NTP-D30 Create Users and Assign Security" procedure on page 4-3 to correct the information.

g. If SNMP is used, click the SNMP tab and verify the trap and destination information. If the information is not correct, see the "NTP-D87 Change SNMP Settings" procedure on page 10-26 to correct the information.

h. Click the DCC/GCC tab. Verify that DCCs were created to the applicable STM-N slots and ports. If DCCs were not created for the appropriate STM-N slots and ports, see Chapter 5, "Turn Up Network" and complete the turn-up procedure appropriate for your network topology.

i. Click the Timing tab. Verify that timing is provisioned as specified. If not, use the "NTP-D85 Change Node Timing" procedure on page 10-18 to make the changes.

j. Click the Alarm Behavior tab. If you provisioned optional alarm profiles, verify that the alarms are provisioned as specified. If not, see the "NTP-D71 Create, Download, and Assign Alarm Severity Profiles" procedure on page 7-17 to change the information.

k. Verify that the network element defaults listed in the status area of the node view window is correct.

Step 7 Repeat Step 6 for each node in the network.

Step 8 As appropriate, complete the circuit creation procedure listed on page 6-1.

Stop. You have completed this procedure.


NTP-D81 Create an Automatically Routed Low-Order VC12 Circuit

Purpose

This procedure creates an automatically routed low-order VC12 circuit, meaning CTC chooses the circuit route based on the parameters you specify and on the software version.

Tools/Equipment

XCVXL 10G or XCVXL 2.5G cards must be installed at the circuit source and destination nodes.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-1), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC12.

Bidirectional—Leave checked for this circuit (default).

Number of Circuits—Type the number of DS-1 circuits you want to create. The default is 1. If you are creating multiple circuits with the same slot and consecutive port numbers, you can use Auto-ranged to create the circuits automatically.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Auto-ranging creates identical (same source and destination), sequential circuits automatically. Deselect the box if you do not want CTC to create sequential circuits automatically.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If low-order circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, low-order circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Select this check box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms are generated if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed on protected drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards and ports as source and destination choices.

Figure 6-1 Setting Circuit Attributes For a Low-Order VC12 Circuit

Step 7 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task. Otherwise, continue with Step 8.

Step 8 Click Next.

Step 9 Complete the "DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination" task.

Step 10 Under Circuit Routing Preferences (Figure 6-2), choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Select this check box if you want to specify nodes and spans to include or exclude in the CTC-generated circuit route.

Review Route Before Creation—Select this check box if you want to review and edit the circuit route before the circuit is created.

Step 11 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. CTC creates a fully-protected circuit route based on the path diversity option you choose. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 14.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, and then continue with Step 14.


Caution Circuits routed on MS-SPRing protection channels are not protected. They are preempted during MS-SPRing switches.

Step 12 If you selected Fully Protected Path in Step 10, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Figure 6-2 Setting Circuit Routing Preferences for a Low-Order VC12 Circuit

Step 13 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 14 If you selected Using Required Nodes/Spans in Step 10, complete the following substeps. If not, continue with Step 17.

a. Click Next.

b. Under Circuit Route Constraints, click a node or span on the circuit map.

c. Click Include to include the node or span in the circuit. Click Exclude to exclude the node or span from the circuit. The order in which you choose included nodes and spans is the order in which the circuit will be routed. Click spans twice to change the circuit direction.

d. Repeat Step c for each node or span you wish to include or exclude.

e. Review the circuit route. To change the circuit routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists and click the Up or Down buttons to change the circuit routing order. Click Remove to remove a node or span.

Step 15 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC12 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC12 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-Order Aggregation Point—This option is available if you are creating a VC12 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC12 circuit source node. This option is available only if the VC12 circuit originates on an STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC12 circuit destination node. This option is available only if the VC12 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 16 If you chose low-order Aggregation Point, complete the following substeps. If not, continue with Step 17.

a. Click Next.

b. On the Low-Order Aggregation Point Destination panel, click the node that you want to be the LAP destination, then click Add Destination.

Step 17 If you selected Review Route Before Creation in Step 10, complete the following substeps. If not, continue with Step 18.

a. Click Next.

b. Review the circuit route. To add or delete a circuit span, choose a node on the circuit route. Blue arrows show the circuit route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned circuit does not reflect the routing and configuration you want, click Back to verify and change circuit information. If the circuit needs to be routed to a different path, see the "82 Create a Manually Routed Low-Order VC12 Circuit" procedure.

Step 18 Click Finish. One of the following results occurs, depending on the circuit properties you chose in the Circuit Creation dialog box:

If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC automatically creates the number of circuits entered in the Number of Circuits field. If auto ranging cannot complete all the circuits, for example, because sequential ports are unavailable at the source or destination, a dialog box is displayed. Set the new source or destination for the remaining circuits, then click Finish to continue auto ranging.

If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

After completing the circuit(s), CTC displays the Circuits window.

Step 19 On the Circuits window, verify that the new circuit(s) appear in the circuits list.

Step 20 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


NTP-D82 Create a Manually Routed Low-Order VC12 Circuit

Purpose

This procedure creates low-order VC12 circuit and allows you to provision the circuit route.

Tools/Equipment

XCVXL 10G or XCVXL 2.5G cards must be installed at the circuit source and destination nodes.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-1), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC12.

Number of Circuits—Type the number of VC12 circuits you want to create. The default is 1. If you are creating multiple circuits with the same slot and consecutive port numbers, you can use Auto-ranged to create the circuits automatically.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Auto-ranging creates identical (same source and destination), sequential circuits automatically. Deselect the box if you do not want CTC to create sequential circuits automatically.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If low-order circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, low-order circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Select this check box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms are generated if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed on protected drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards and ports as source and destination choices.

Step 7 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task. Otherwise, continue with Step 8.

Step 8 Click Next.

Step 9 Complete the "DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination" task.

Step 10 Under Circuit Routing Preferences (see Figure 6-2), deselect Route Automatically.

Step 11 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 16.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, and then continue with Step 16.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 12 If you selected Fully Protected Path, choose a Node-Diverse Path option:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired— Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Step 13 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 14 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC12 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC12 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-order Aggregation Point—This option is available if you are creating a VC12 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC12 circuit source node. This option is available only if the VC12 circuit originates on an STM1E-12, DS3i-N-12, or STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC12 circuit destination node. This option is available only if the VC12 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 15 If you chose Low-Order Aggregation Point, complete the following substeps. If not, continue with Step 16.

a. Click Next.

b. On the Low-Order Aggregation Point Destination panel, click the node that you want to be the LAP destination, then click Add Destination.

Step 16 Click Next. Under Route Review and Edit, node icons are displayed to route the circuit. The circuit source node is selected. Green arrows pointing from the source node to other network nodes indicate spans that are available for routing the circuit.

Step 17 Complete the "DLP-D96 Provision a Low-Order VC3 Circuit Route" task for the VC12 circuit you are creating.

Step 18 Click Finish. CTC will compare your manually-provisioned circuit route with the specified path diversity option you chose in Step 12. If the path does not meet the specified path diversity requirement, CTC displays an error message and allows you to change the circuit path. If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

Step 19 When all the circuits are created, CTC displays the main Circuits window. Verify that the circuit(s) you created are correct.

Step 20 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


NTP-D83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops

Purpose

This procedure creates a unidirectional low-order VC12 circuit with multiple drops (destinations).

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-3), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC12.

Bidirectional—Deselect for this circuit.

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable when the Number of Circuits field is 1.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If the VC12 circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, the VC12 circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Check this box if you want the circuit routed to protect drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you check this box, CTC displays only protected cards as source and destination choices.

Figure 6-3 Setting Circuit Attributes for a Unidirectional Low-Order VC12 Circuit

Step 7 Click Next.

Step 8 Complete the "DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination" task.

Step 9 Under Circuit Routing Preferences, deselect Route Automatically. When Route Automatically is not selected, Using Required Nodes/Spans and Review Route Before Circuit Creation are unavailable.

Step 10 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 16.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, and then continue with Step 16.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 11 If you selected Fully Protected Path, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Step 12 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 13 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC12 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC12 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-order Aggregation Point—This option is available if you are creating a VC12 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC12 circuit source node. This option is available only if the VC12 circuit originates on an STM1E-12, DS3i-N-12, or STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC12 circuit destination node. This option is available only if the VC12 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 14 If you chose Low-Order Aggregation Point, complete the following substeps. If not, continue with Step 16.

a. Click Next.

b. On the Low-Order Aggregation Point Destination panel, click the node that you want to be the LAP destination, then click Add Destination.

Step 15 Click Next. Under Route Review and Edit, node icons are displayed so you can route the circuit manually. The circuit source node is selected. Green arrows pointing from the source node to other network nodes indicate spans that are available for routing the circuit.

Step 16 Complete the "DLP-D96 Provision a Low-Order VC12 Circuit Route" task for the VC12 circuit you are creating.

Step 17 Click Finish. CTC completes the circuit and displays the Circuits window.

Step 18 On the Circuits window, click the circuit that you want to route to multiple drops. The Delete, Edit, and Search buttons become active.

Step 19 Click Edit (or double-click the circuit row). The Edit Circuit window is displayed with the General tab selected.

All nodes in the DCC network are displayed on the network. Circuit source and destination information appears under the source and destination nodes. To display a detailed view of the circuit, click Show Detailed Map. To rearrange a node icon, select the node, press Ctrl, then drag and drop the icon to the new location.

Step 20 On the Edit Circuit dialog box, click the Drops tab. A list of existing drops is displayed.

Step 21 Click Create.

Step 22 On the Define New Drop dialog box, create the new drop:

a. Node—Choose the target node for the circuit drop.

b. Slot—Choose the target card and slot.

c. Port, VC4, VC3, TUG3, TUG2, VC12—Choose the Port, VC4, VC3, TUG3, TUG2, or VC12 from the Port, VC4, VC3, TUG3, TUG2, or VC12 pull-down menus. The card selected in Step b determines the fields that display. See Table 6-3 for a list of options.

d. The routing preferences for the new drop will match those of the original circuit. However, you can modify the following:

If the original circuit was routed on a protected path, you can change the nodal diversity options: Required, Desired, Don't Care; Link Diverse only. See Step 12 for descriptions.

If the original circuit was not routed on a protected path, the Protection Channel Access options is available. See Step 11 for a description of the PCA option.

e. Click OK. The new drop appears in the Drops list.

Step 23 If you need to create additional drops for the circuit, repeat Step 21 and 22 to create the additional drops.

Step 24 Click Close. The Circuits window is displayed.

Step 25 Verify that the new drops are displayed under the Destination column for the circuit you edited. If they do not appear repeat Steps 5 through 25, making sure all options are provisioned correctly.

Step 26 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


DLP-D317 Verify XCVXL Card Installation

Purpose

This task verifies the installation of XCVXL 10G or XCVXL 2.5 cross-connect cards. These cards are required for low-order circuits.

Tools/Equipment

None

Prerequisite Procedures

None

Required/As Needed

As needed.

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Display the low-order circuit source node in node view.

Step 2 On the shelf graphic, verify that XCVXL 10G or XCVXL 2.5G cross-connect cards are installedin Slots 8 and 10.

Step 3 Display the low-order circuit destination node in node view and repeat Step 2.

Step 4 If the circuit source or destination node does not have XCVXL cards installed, complete the "NTP-D92 Upgrade the XC10G Card to the XCVXL Card" procedure on page 12-5.

Step 5 Return to your originating procedure (NTP).


DLP-D314 Assign a Name to a Port

Purpose

This task assigns a name to a port on any ONS 15454 SDH card.

Tools/Equipment

None

Prerequisite Procedures

NTP-D24 Verify Card Installation, page 4-2

Required/As Needed

As needed.

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into the node where you want to assign a port name for a card or cards. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions.

Step 2 Double-click the card that has the port you want to provision.

Step 3 Click the Provisioning tab.

Step 4 Click the Port Name column for the port number you are assigning a name to and enter the desired port name.

The port name can be up to 32 alphanumeric/special characters and is blank by default.

Step 5 Click Apply.

Step 6 Return to your originating procedure (NTP).


DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination

Purpose

This task provisions an electrical circuit source and destination for a low-order VC12 circuit.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during one of the following procedures:

81 Create an Automatically Routed Low-Order VC12 Circuit, or

82 Create a Manually Routed Low-Order VC12 Circuit, or

83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note After you have selected the circuit properties in the Circuit Source dialog box according to the specific circuit creation procedure, you are ready to provision the circuit source.



Step 1 From the Node pull-down menu, choose the node where the source will originate.

Step 2 From the Slot pull-down menu, choose the slot containing the E1-N-14 card (Figure 6-4) or E1-42 card (Figure 6-5) where the circuit will originate.

Figure 6-4 Defining the Circuit Source on a E1-N-14 Card

Figure 6-5 Defining the Circuit Source on a E1-42 Card

Step 3 Choose the port from the Port pull-down menu.

Step 4 Only if you choose the E1_42 card, choose the source TUG3 from the TUG3 pull-down menu.

Step 5 From the TUG2 pull-down menu, choose the source TUG2.

Step 6 From the VC12 pull-down menu, choose the source VC12.

Step 7 If you need to create a secondary source, for example, an SNCP ring bridge/selector circuit entry point in a multivendor SNCP ring, click Use Secondary Source and repeat Steps 1 through 5 to define the secondary source. If you do not need to create a secondary source, continue with Step 8.

Step 8 Click Next.

Step 9 From the Node pull-down menu, choose the destination (termination) node.

Step 10 From the Slot pull-down menu, choose the slot containing the destination card. The destination is typically a E1 card. However, you can also choose an STM-N card to map the VC12 to a VC4 for optical transport.

Step 11 Depending on the destination card, choose the destination port from the sub-menus that display based on the card selected in Step 10. See Table 6-2 for a list of valid options. CTC does not display ports, VC4s, TUG3s, TUG2s, or VC12s already used by other circuits. If you and a user working on the same network choose the same VC4, TUG3, TUG2, or VC12 simultaneously, one of you will receive a Path in Use error and be unable to complete the circuit. The user with the incomplete circuit needs to choose new destination parameters.

Step 12 If you need to create a secondary destination, for example, an SNCP ring bridge/selector circuit exit point in a multivendor SNCP ring, click Use Secondary Destination and repeat Steps 9 through 11 to define the secondary destination.

Step 13 Click Next.

Step 14 Return to your originating procedure (NTP).


DLP-D96 Provision a Low-Order VC12 Circuit Route

Purpose

This task provisions the circuit route for low-order VC12 manually-routed circuits.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during one of the following procedures:

82 Create a Manually Routed Low-Order VC12 Circuit, or

83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops, or

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 On the Circuit Creation wizard under Route Review and Edit, click the source node icon if it is not already selected.

Step 2 Starting with a span on the source node, click the arrow of the span you want the circuit to travel. The arrow turns white. Under Selected Span, the From and To fields display span information. The source VC12 is displayed.

Step 3 If you want to change the source VC12, adjust the Source VC12 field; otherwise, continue with Step 4.

Step 4 If you want to change the source TUG2, TUG3, VC3 or VC4, adjust the TUG2, TUG3, VC3 or VC4 fields; otherwise, continue with Step 5.

Step 5 Click Add Span.The span is added to the Included Spans list and the span arrow turns blue.

Repeat Steps 2 through 5 until the circuit is provisioned from the source to the destination node through all intermediary nodes. If Fully Protect Path is checked on the Circuit Routing Preferences panel, you must:

Add two spans for all SNCP ring or unprotected portions of the circuit route from the source to the destination

Add one span for all MS-SPRing or 1+1 portions of route from the source to the destination

Step 6 Return to your originating procedure (NTP).


NTP-D54 Create an Automatically Routed Low-Order VC3 Circuit

Purpose

This procedure creates an automatically routed low-order VC12 circuit, meaning CTC chooses the circuit route based on the parameters you specify and on the software version.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

XCVXL 10G or XCVXL 2.5G cards must be installed at the circuit source and destination nodes.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-6), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC3.

Number of Circuits—Type the number of VC3 circuits you want to create. The default is 1. If you are creating multiple circuits with the same slot and consecutive port numbers, you can use Auto-ranged to create the circuits automatically.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Auto-ranging creates identical (same source and destination), sequential circuits automatically. Deselect the box if you do not want CTC to create sequential circuits automatically.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If low-order circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, low-order circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Select this check box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms are generated if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed on protected drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards and ports as source and destination choices.

Figure 6-6 Setting Circuit Attributes For a Low-Order VC3 Circuit

Step 7 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task. Otherwise, continue with Step 8.

Step 8 Click Next.

Step 9 Complete the "DLP-D218 Provision a Low-Order VC3 Circuit Source and Destination" task.

Step 10 Under Circuit Routing Preferences (Figure 6-7), choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Select this check box if you want to specify nodes and spans to include or exclude in the CTC-generated circuit route.

Review Route Before Creation—Select this check box if you want to review and edit the circuit route before the circuit is created.

Step 11 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. CTC creates a fully-protected circuit route based on the path diversity option you choose. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 14.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, and then continue with Step 14.


Caution Circuits routed on MS-SPRing protection channels are not protected. They are preempted during MS-SPRing switches.

Step 12 If you selected Fully Protected Path in Step 10, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Figure 6-7 Setting Circuit Routing Preferences for a Low-Order VC3 Circuit

Step 13 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 14 If you selected Using Required Nodes/Spans in Step 10, complete the following substeps. If not, continue with Step 17.

a. Click Next.

b. Under Circuit Route Constraints, click a node or span on the circuit map.

c. Click Include to include the node or span in the circuit. Click Exclude to exclude the node or span from the circuit. The order in which you choose included nodes and spans is the order in which the circuit will be routed. Click spans twice to change the circuit direction.

d. Repeat Step c for each node or span you wish to include or exclude.

e. Review the circuit route. To change the circuit routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists and click the Up or Down buttons to change the circuit routing order. Click Remove to remove a node or span.

Step 15 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC3 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC3 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-order Aggregation Point—This option is available if you are creating a VC3 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC12 circuit source node. This option is available only if the VC3 circuit originates on an STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC3 circuit destination node. This option is available only if the VC3 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 16 If you chose low-order Aggregation Point, complete the following substeps. If not, continue with Step 17.

a. Click Next.

b. On the Low-Order Aggregation Point Destination panel, click the node that you want to be the LAP destination, then click Add Destination.

Step 17 If you selected Review Route Before Creation in Step 10, complete the following substeps. If not, continue with Step 18.

a. Click Next.

b. Review the circuit route. To add or delete a circuit span, choose a node on the circuit route. Blue arrows show the circuit route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned circuit does not reflect the routing and configuration you want, click Back to verify and change circuit information. If the circuit needs to be routed to a different path, see the "82 Create a Manually Routed Low-Order VC12 Circuit" procedure.

Step 18 Click Finish. One of the following results occurs, depending on the circuit properties you chose in the Circuit Creation dialog box:

If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC automatically creates the number of circuits entered in the Number of Circuits field. If auto ranging cannot complete all the circuits, for example, because sequential ports are unavailable at the source or destination, a dialog box is displayed. Set the new source or destination for the remaining circuits, then click Finish to continue auto ranging.

If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

After completing the circuit(s), CTC displays the Circuits window.

Step 19 On the Circuits window, verify that the new circuit(s) appear in the circuits list.

Step 20 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


NTP-D55 Create a Manually Routed Low-Order VC3 Circuit

Purpose

This procedure creates low-order VC3 circuit and allows you to provision the circuit route.

Tools/Equipment

XCVXL 10G or XCVXL 2.5G cards must be installed at the circuit source and destination nodes.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-6), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC3.

Number of Circuits—Type the number of VC3 circuits you want to create. The default is 1. If you are creating multiple circuits with the same slot and consecutive port numbers, you can use Auto-ranged to create the circuits automatically.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Auto-ranging creates identical (same source and destination), sequential circuits automatically. Deselect the box if you do not want CTC to create sequential circuits automatically.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If low-order circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, low-order circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Select this check box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms are generated if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plan e (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed on protected drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards and ports as source and destination choices.

Step 7 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task. Otherwise, continue with Step 8.

Step 8 Click Next.

Step 9 Complete the "DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination" task.

Step 10 Under Circuit Routing Preferences (see Figure 6-2), deselect Route Automatically.

Step 11 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 16.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, then continue with Step 16.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 12 If you selected Fully Protected Path in Step 11, choose a Node-Diverse Path option:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired— Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Step 13 If you selected Fully Protected Path Step 11 and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 14 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC3 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC3 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-order Aggregation Point—This option is available if you are creating a VC3 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC3 circuit source node. This option is available only if the VC3 circuit originates on an STM1E-12, DS3i-N-12, or STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC3 circuit destination node. This option is available only if the VC3 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 15 If you chose Low-Order Aggregation Point in Step 14, complete the following substeps. If not, continue with Step 16.

a. Click Next.

b. Under Select Low-Order Grooming Node, click the node that you want to be the LAP grooming node, then click Add Destination.

Step 16 Click Next. Under Route Review and Edit, node icons are displayed to route the circuit. The circuit source node is selected. Green arrows pointing from the source node to other network nodes indicate spans that are available for routing the circuit.

Step 17 Complete the "DLP-D96 Provision a Low-Order VC3 Circuit Route" task for the VC3 circuit you are creating.

Step 18 Click Finish. CTC will compare your manually-provisioned circuit route with the specified path diversity option you chose in Step 12. If the path does not meet the specified path diversity requirement, CTC displays an error message and allows you to change the circuit path. If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

Step 19 When all the circuits are created, CTC displays the main Circuits window. Verify that the circuit(s) you created are correct.

Step 20 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


NTP-D56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

Purpose

This procedure creates a unidirectional low-order VC3 circuit with multiple drops (destinations).

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 Complete the "DLP-D317 Verify XCVXL Card Installation" task.

Step 3 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 4 From the View menu, choose Go to Network View.

Step 5 Click the Circuits tab, then click Create.

Step 6 In the Circuit Creation dialog box (Figure 6-8), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters, (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_LO_PATH_CIRCUIT.

Size—Choose VC3.

Bidirectional—Deselect for this circuit.

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable when the Number of Circuits field is 1.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.


Note If the VC3 circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, the VC3 circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.


Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Check this box if you want the circuit routed to protect drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you check this box, CTC displays only protected cards as source and destination choices.

Figure 6-8 Setting Circuit Attributes for a Unidirectional Low-Order VC3 Circuit

Step 7 Click Next.

Step 8 Complete the "DLP-D218 Provision a Low-Order VC3 Circuit Source and Destination" task.

Step 9 Under Circuit Routing Preferences, deselect Route Automatically. When Route Automatically is not selected, Using Required Nodes/Spans and Review Route Before Circuit Creation are unavailable.

Step 10 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 12. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 16.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, then continue with Step 16.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 11 If you selected Fully Protected Path, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Step 12 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 13 Click Next. On the Low-Order Circuit panel under Create, choose one of the following:

Low-Order Tunnel on Transit Nodes—This option is available if the VC3 circuit passes through a node that does not have a low-order tunnel, or if an existing low-order tunnel is full. Low-order tunnels allow VC3 circuits to pass through ONS 15454 SDHs without consuming cross-connect card resources. Low-order tunnels are required if the circuit passes through a node with XC10G cross-connect cards. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Cisco ONS 15454 SDH Reference Manual for more information.

Low-order Aggregation Point—This option is available if you are creating a VC3 circuit to an STM-N port. A low-order aggregation point (LAP) allows low-order circuits to be routed through a node using one VC4 connection on the cross-connect card matrix rather than multiple connections on the low-order matrix. If available, choose one of the following:

Use source as the VC4 grooming end—Creates the LAP on the VC3 circuit source node. This option is available only if the VC3 circuit originates on an STM1E-12, DS3i-N-12, or STM-N card.

Use destination as the VC4 grooming end—Creates the LAP on the VC3 circuit destination node. This option is available only if the VC3 circuit terminates on an STM-N card.

None—Choose this option if you do not want to create a low-order tunnel or a LAP. This will be the only available option if CTC cannot create a low-order tunnel or LAP.

Step 14 If you chose Low-Order Aggregation Point, complete the following substeps. If not, continue with Step 15.

a. Click Next.

b. On the Low-Order Aggregation Point Destination panel, click the node that you want to be the LAP destination, then click Add Destination.

Step 15 Click Next. Under Route Review and Edit, node icons are displayed so you can route the circuit manually. The circuit source node is selected. Green arrows pointing from the source node to other network nodes indicate spans that are available for routing the circuit.

Step 16 Complete the "DLP-D96 Provision a Low-Order VC3 Circuit Route" task for the VC3 circuit you are creating.

Step 17 Click Finish. CTC completes the circuit and displays the Circuits window.

Step 18 On the Circuits window, click the circuit that you want to route to multiple drops. The Delete, Edit, and Search buttons become active.

Step 19 Click Edit (or double-click the circuit row). The Edit Circuit window is displayed with the General tab selected.

All nodes in the DCC network are displayed on the network. Circuit source and destination information appears under the source and destination nodes. To display a detailed view of the circuit, click Show Detailed Map. To rearrange a node icon, select the node, press Ctrl, then drag and drop the icon to the new location.

Step 20 On the Edit Circuit dialog box, click the Drops tab. A list of existing drops is displayed.

Step 21 Click Create.

Step 22 On the Define New Drop dialog box, create the new drop:

a. Node—Choose the target node for the circuit drop.

b. Slot—Choose the target card and slot.

c. Port, VC4, or VC3—Choose the Port, VC4, or VC3 from the Port, VC4, or VC3 pull-down menus. The card selected in Step b determines the fields that display. See Table 6-3 for a list of options.

d. The routing preferences for the new drop will match those of the original circuit. However, you can modify the following:

If the original circuit was routed on a protected path, you can change the nodal diversity options: Required, Desired, Don't Care; Link Diverse only. See Step 12 for descriptions.

If the original circuit was not routed on a protected path, the Protection Channel Access options is available. See Step 11 for a description of the PCA option.

e. Click OK. The new drop appears in the Drops list.

Step 23 If you need to create additional drops for the circuit, repeat Step 21 and 22 to create the additional drops.

Step 24 Choose Close. The Circuits window is displayed.

Step 25 Verify that the new drops are displayed under the Destination column for the circuit you edited. If they do not appear repeat Steps 5 through 25, making sure all options are provisioned correctly.

Step 26 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


DLP-D218 Provision SNCP Ring Selectors During Circuit Creation

Purpose

This task provisions SNCP ring selectors during circuit creation. Use this task only if the circuit will be routed on an SNCP ring.

Tools/Equipment

None

Prerequisite Procedures

You must have the Circuit Creation wizard displayed.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 On the Circuit Attributes panel of the Circuit Creation wizard, set the SNCP path selectors:

Revertive—Check this box if you want traffic to revert to the working path when the conditions that diverted it to the protect path are repaired. If you do not choose Revertive, traffic remains on the protect path after the switch.

Reversion time—If Revertive is checked, click the Reversion time field and choose a reversion time from the pull-down menu. The range is 0.5 to 12.0 minutes. The default is 5.0 minutes. This is the amount of time that will elapse before the traffic reverts to the working path. Traffic can revert when conditions causing the switch are cleared.

SF threshold—For high-order circuits, set the SNCP path-level signal failure bit error rate (BER) thresholds. Unavailable for low-order circuits.

SD threshold—For high-order circuits, set the SNCP path-level signal degrade BER thresholds. Unavailable for low-order circuits.

Switch on PDI-P—For high-order circuits, check this box if you want traffic to switch when an high-order payload defect indicator is received. Unavailable for low-order circuits.

Step 2 Return to your originating procedure (NTP).


DLP-D218 Provision a Low-Order VC3 Circuit Source and Destination

Purpose

This task provisions an electrical circuit source and destination for a low-order VC3 circuit.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during one of the following procedures:

54 Create an Automatically Routed Low-Order VC3 Circuit, or

55 Create a Manually Routed Low-Order VC3 Circuit, or

56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note After you have selected the circuit properties in the Circuit Source dialog box according to the specific circuit creation procedure, you are ready to provision the circuit source.



Step 1 From the Node pull-down menu, choose the node where the source will originate.

Step 2 From the Slot pull-down menu, choose the slot containing the E3-12 or DS3i-N-12 card where the circuit will originate. Figure 6-9 shows an example circuit source for an E3-12 card.

Figure 6-9 Defining the Circuit Source on a E3-12 Card

Step 3 Choose the port from the Port pull-down menu.

Step 4 Choose the VC4 from the VC4 pull-down menu.

Step 5 Choose the VC3 from the VC3 pull-down menu.

Step 6 If you need to create a secondary source, for example, an SNCP ring bridge/selector circuit entry point in a multivendor SNCP ring, click Use Secondary Source and repeat Steps 1 through 5 to define the secondary source. If you do not need to create a secondary source, continue with Step 8.

Step 7 Click Next.

Step 8 From the Node pull-down menu, choose the destination (termination) node.

Step 9 From the Slot pull-down menu, choose the slot containing the destination card. The destination is typically a E3 or DS3 card. However, you can also choose an STM-N card to map the VC3 to a VC4 for optical transport.

Step 10 Depending on the destination card, choose the destination port from the sub-menus that display based on the card selected in Step 2. See Table 6-2 for a list of valid options. CTC does not display ports, VC4s, or VC3s already used by other circuits. If you and a user working on the same network choose the same port, VC4, or VC3 simultaneously, one of you will receive a Path in Use error and be unable to complete the circuit. The user with the incomplete circuit needs to choose new destination parameters.

Step 11 If you need to create a secondary destination, for example, an SNCP ring bridge/selector circuit exit point in a multivendor SNCP ring, click Use Secondary Destination and repeat Steps 9 through 11 to define the secondary destination.

Step 12 Click Next.

Step 13 Return to your originating procedure (NTP).


DLP-D96 Provision a Low-Order VC3 Circuit Route

Purpose

This task provisions the circuit route for manually-routed low-order VC3 circuits.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during one of the following procedures:

55 Create a Manually Routed Low-Order VC3 Circuit, or

56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 On the Circuit Creation wizard under Route Review and Edit, click the source node icon if it is not already selected.

Step 2 Starting with a span on the source node, click the arrow of the span you want the circuit to travel. The arrow turns white. Under Selected Span, the From and To fields display span information. The source VC3 is displayed.

Step 3 If you want to change the source VC3, adjust the Source VC3 field; otherwise, continue with Step 4.

Step 4 If you want to change the source VC4, adjust the Source VC4 field; otherwise, continue with Step 5.

Step 5 Click Add Span.The span is added to the Included Spans list and the span arrow turns blue.

Step 6 Repeat Steps 2 through 5 until the circuit is provisioned from the source to the destination node through all intermediary nodes. If Fully Protect Path is checked on the Circuit Routing Preferences panel, you must:

Add two spans for all SNCP ring or unprotected portions of the circuit route from the source to the destination

Add one span for all MS-SPRing or 1+1 portions of route from the source to the destination

Step 7 Return to your originating procedure (NTP).


NTP-D133 Create an Automatically Routed Low-Order Tunnel

Purpose

This procedure creates an automatically routed low-order tunnel from source to destination nodes.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note Low-order tunnels allow low-order VC12 and VC3 circuits to pass through intermediary ONS 15454 SDH nodes without consuming low-order matrix resources on the cross-connect card. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Low-order tunnels are required if low-order circuits must pass through nodes with XC10G cross-connect cards. Refer to the Circuits and Tunnels chapter in the Cisco ONS 15454 SDH Reference Manual for more information.



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box (Figure 6-10), complete the following fields:

Name—Assign a name to the low-order tunnel. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the tunnel.

Type—Choose VC_LO_PATH TUNNEL. The Bidirectional, Number of Circuits, and Field Size fields in the dialog box become unavailable.

Size—The default size is VC4. You cannot change this value.

For VC3 Port Grouping Only—Leave this box unchecked.

Bidirectional—Unavailable for low-order tunnels.

Number of Circuits—Unavailable for low-order tunnels.

Auto-ranged—Unavailable for low-order tunnels.

State—Choose a service state to apply to the low-order tunnel:

IS—The low-order tunnel is in service.

OOS—The low-order tunnel is out of service. Traffic is not passed on the circuit.

OOS-AINS—The low-order tunnel is in service when it receives a valid signal; until then, the tunnel is out of service.

OOS-MT—The low-order tunnel is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the tunnel. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the tunnel will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Figure 6-10 Setting Attributes for a Low-Order Tunnel

Step 6 Click Next.

Step 7 Under Circuit Source, choose the node where the low-order tunnel will originate from the Node pull-down menu.

Step 8 Click Next.

Step 9 Under Circuit Destination, choose the node where the low-order tunnel will terminate from the Node pull-down menu.

Step 10 Click Next.

Step 11 Under Circuit Routing Preferences, choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Select this check box to specify nodes and spans to include or exclude in the CTC-generated tunnel route.

Review Route Before Creation—Select this check box to review and edit the low-order tunnel route before the circuit is created.

Step 12 If you selected Using Required Nodes/Spans:

a. Click Next.

b. Under Circuit Route Constraints, click a span on the low-order tunnel map.

c. Click Include to include the node or span in the low-order tunnel. Click Exclude to exclude the node or span from the low-order tunnel. The order in which you choose included nodes and spans sets the low-order tunnel sequence. Click spans twice to change the circuit direction.

d. Repeat Step c for each node or span you wish to include or exclude.

e. Review the low-order tunnel route. To change the tunnel routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists, then click the Up or Down buttons to change the tunnel routing order. Click Remove to remove a node or span.

Step 13 If you selected Review Route Before Creation:

a. Click Next.

b. Review the tunnel route. To add or delete a tunnel span, choose a node on the tunnel route. Blue arrows show the tunnel route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned tunnel does not reflect the routing and configuration you want, click Back to verify and change tunnel information.

Step 14 Click Finish. The Circuits window displays.

Step 15 Verify that the tunnel you just created appears in the circuits list. Low-order tunnels are identified by LOT in the Type column.

Stop. You have completed this procedure.


NTP-D134 Create a Manually Routed Low-Order Tunnel

Purpose

This procedure creates a manually routed, low-order tunnel from source to destination nodes.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note Low-order tunnels allow low-order circuits to pass through intermediary ONS 15454 SDHs without consuming low-order matrix resources on the cross-connect card. In general, creating low-order tunnels is a good idea if you are creating many low-order circuits from the same source and destination. Refer to the Circuits and Tunnels chapter in the Cisco ONS 15454 SDH Reference Manual for more information.



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 4.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box (Figure 6-11), complete the following fields:

Name—Assign a name to the low-order tunnel. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the tunnel.

Type—Choose VC_LO_PATH TUNNEL. The Bidirectional, Number of Circuits, and Field Size fields in the dialog box become unavailable.

Size—The default size is VC4. You cannot change this value.

For VC3 Port Grouping Only—Leave this box unchecked.

Bidirectional—Unavailable for low-order tunnels.

Number of Circuits—Unavailable for low-order tunnels.

Auto-ranged—Unavailable for low-order tunnels.

State—Choose a service state to apply to the low-order tunnel:

IS—The low-order tunnel is in service.

OOS—The low-order tunnel is out of service. Traffic is not passed on the circuit.

OOS-AINS—The low-order tunnel is in service when it receives a valid signal; until then, the circuit is out of service.

OOS-MT—The low-order tunnel is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed. Use OOS-MT for testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the tunnel will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Step 6 Click Next.

Step 7 Under Circuit Source, choose the node where the low-order tunnel will originate from the Node pull-down menu.

Step 8 Click Next.

Step 9 Under Circuit Destination, choose the node where the low-order tunnel will terminate from the Node pull-down menu.

Step 10 Click Next.

Step 11 Under Circuit Routing Preferences, deselect Route Automatically.

Step 12 Click Next. Under Route Review and Edit, node icons are displayed to route the tunnel. The circuit source node is selected. Green arrows pointing from the source node to other network nodes indicate spans that are available for routing the tunnel.

Step 13 Complete the "DLP-D219 Provision a Low-Order Tunnel Route" task for the tunnel you are creating. The Circuits window displays.

Step 14 Verify that the tunnel you just created appears in the circuits list. Low-order tunnels are identified by LOT in the Type column.

Stop. You have completed this procedure.


DLP-D219 Provision a Low-Order Tunnel Route

Purpose

This task provisions the route for a manually-routed low-order tunnel.

Tools/Equipment

None

Prerequisite Procedures

Perform this task as part of the "134 Create a Manually Routed Low-Order Tunnel" procedure.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 On the Circuit Creation wizard under Route Review and Edit, click the source node icon if it is not already selected. Arrows indicate the available spans for routing the tunnel from the source node.

Step 2 Click the arrow of the span you want the low-order tunnel to travel. The arrow turns white. Under Selected Span, the From and To fields display the slot and port that will carry the tunnel. The source VC4 is displayed.

Step 3 If you want to change the source VC4, change it in the Source VC4 field; otherwise, continue with Step 4.

Step 4 Click Add Span.The span is added to the Included Spans list and the span arrow turns blue.

Step 5 Repeat Steps 3 and 4 until the tunnel is provisioned from the source to the destination node through all intermediary nodes.

Step 6 Return to the "134 Create a Manually Routed Low-Order Tunnel" procedure.


NTP-D216 Create a Low-Order Path Tunnel for Port Grouping

Purpose

This procedure creates a low-order path tunnel for the E3 and DS3I cards in networks with XC10G cross-connect cards installed. The XC10G card creates only VC4-level port groups, so VC4 tunnels must be used to transport VC3 signal rates.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box complete the following fields:

Name—Assign a name to the low-order tunnel. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the tunnel.

Type—Choose VC_LO_PATH TUNNEL. The Bidirectional, Number of Circuits, and Field Size fields in the dialog box become unavailable.

Size—The default size is VC4. You cannot change this value.

For VC3 Port Grouping Only—Check this box.

Bidirectional—This check box is automatically selected.

Number of Circuits—This field automatically lists one port group.

Three ports form one port group. For example, in one E3 or one DS3I card, there are four port groups:

Ports 1 to 3 = PG1

Ports 4 to 6 = PG2

Ports 7 to 9 = PG3

Ports 10 to 12 = PG4

Low-order path tunneling is performed at the VC3 level.

Auto-ranged—This check box is automatically selected.

State—Choose a service state to apply to the low-order tunnel:

IS—The low-order tunnel is in service.

OOS—The low-order tunnel is out of service. Traffic is not passed on the circuit.

OOS-AINS—The low-order tunnel is in service when it receives a valid signal; until then, the tunnel is out of service.

OOS-MT—The low-order tunnel is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the tunnel. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the tunnel will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Step 6 If the tunnel will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task. Otherwise, continue with Step 7.

Step 7 Click Next.

Step 8 Under Circuit Source, choose the node where the low-order tunnel will originate from the Node pull-down menu.

Step 9 Click Next.

Step 10 Under Circuit Destination, choose the node where the low-order tunnel will terminate from the Node pull-down menu.

Step 11 Click Next.

Step 12 Under Circuit Routing Preferences, choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Select this check box to specify nodes and spans to include or exclude in the CTC-generated tunnel route.

Review Route Before Creation—Select this check box to review and edit the low-order tunnel route before the circuit is created.

Step 13 If you selected Using Required Nodes/Spans:

a. Click Next.

b. Under Circuit Route Constraints, click a span on the low-order tunnel map.

c. Click Include to include the node or span in the low-order tunnel. Click Exclude to exclude the node or span from the low-order tunnel. The order in which you choose included nodes and spans sets the low-order tunnel sequence. Click spans twice to change the circuit direction.

d. Repeat Step c for each node or span you wish to include or exclude.

e. Review the low-order tunnel route. To change the tunnel routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists, then click the Up or Down buttons to change the tunnel routing order. Click Remove to remove a node or span.

Step 14 If you selected Review Route Before Creation:

a. Click Next.

b. Review the tunnel route. To add or delete a tunnel span, choose a node on the tunnel route. Blue arrows show the tunnel route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned tunnel does not reflect the routing and configuration you want, click Back to verify and change tunnel information.

Step 15 Click Finish. The Circuits window displays.

Step 16 Verify that the tunnel you just created appears in the circuits list. Low-order tunnels are identified by LOT in the Type column.

Stop. You have completed this procedure.


NTP-D187 Create a Low-Order Aggregation Point

Purpose

This procedure creates a low-order aggregation point (LAP). LAPs allow multiple VC3 or VC12 low-order circuits to be aggregated on a single VC4 circuit. LAPs allow multiple low-order circuits to pass through cross-connect cards without utilizing resources on the cross-connect card low-order matrix.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note You can create low-order aggregation points for circuits in MS-SPRing or 1+1 protection, or for unprotected circuits. You cannot create them for SNCP ring circuits.



Note The maximum number of LAPs that you can create depends on the node protection topology and number of low-order circuits that terminate on the node. Assuming no other low-order circuits terminate at the node, the maximum number of LAPs that you can terminate at one node is 8 for 1+1 and 12 for MS-SPRing protection.



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box (Figure 6-11), complete the following fields:

Name—Assign a name to the low-order aggregation point. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the LAP.

Type—Choose VC_LOW_PATH_AGGREGATION. The Size, Bidirectional, and Number of Circuits fields become unavailable.

Size—Unavailable for LAPs.

Bidirectional—Unavailable for LAPs.

Number of Circuits—Unavailable for LAPs.

Auto-ranged—Unavailable for LAPs.

State—Choose a service state to apply to the LAP:

IS—The LAP is in service.

OOS—The LAP is out of service. Traffic is not passed on the circuit.

OOS-AINS—The LAP is in service when it receives a valid signal; until then, the tunnel is out of service.

OOS-MT—The LAP is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the LAP. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the LAP will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Figure 6-11 Setting Attributes for a Low-Order Aggregation Point


Note LAPs cannot be be routed on an SNCP ring, so the SNCP path selectors do not apply.


Step 6 Click Next.

Step 7 Under Circuit Source, choose the source node, slot, port, and VC4 for the LAP. The LAP source is where the low-order circuits will be aggregated into a single VC4. The LAP destination is where the low-order circuits originate.

a. From the Node pull-down menu, choose the node where the LAP will originate.

b. From the Slot pull-down menu, choose the slot containing the STM-N, STM-N, E3-12, DS3i, or STM1E-12 card where the LAP will originate.

c. Depending on the card chosen in Step b, choose the port and/or VC4 from the Port and VC4 pull-down menus.

Step 8 Click Next.

Step 9 Under Circuit Destination, choose the node where the low-order circuits aggregated by the LAP will terminate from the Node pull-down menu.

Step 10 Click Next.

Step 11 Under Circuit Routing Preferences, choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Select this check box to specify nodes and spans to include or exclude in the CTC-generated tunnel route.

Review Route Before Creation—Select this check box to review and edit the VT tunnel route before the circuit is created.

Step 12 If you selected Using Required Nodes/Spans:

a. Click Next.

b. Under Circuit Route Constraints, click a span on the LAP map.

c. Click Include to include the node or span in the LAP. Click Exclude to exclude the node or span from the LAP. The sequence in which you choose the nodes and spans sets the LAP sequence. Click spans twice to change the circuit direction.

d. Repeat Step c for each node or span you wish to include or exclude.

e. Review the LAP route. To change the tunnel routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists, then click the Up or Down buttons to change the tunnel routing order. Click Remove to remove a node or span.

Step 13 If you selected Review Route Before Creation:

a. Click Next.

b. Review the tunnel route. To add or delete a tunnel span, choose a node on the tunnel route. Blue arrows show the tunnel route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned tunnel does not reflect the routing and configuration you want, click Back to verify and change tunnel information.

Step 14 Click Finish. The Circuits window displays.

Step 15 Verify that the LAP you just created appears in the circuits list. LAPs are identified in the Type column.

Stop. You have completed this procedure.


NTP-D135 Test Low-Order Circuits

Purpose

This procedure tests low-order VC12 and VC3 circuits.

Tools/Equipment

A test set and all appropriate cables

Prerequisite Procedures

This procedure assumes you completed a facility loopback tests on the fibers and cables from the source and destination ONS 15454 SDHs to the DSX, and that you created a circuit using one of the following procedures:

81 Create an Automatically Routed Low-Order VC12 Circuit

82 Create a Manually Routed Low-Order VC12 Circuit

83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops

54 Create an Automatically Routed Low-Order VC3 Circuit

55 Create a Manually Routed Low-Order VC3 Circuit

56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

Required/As Needed

Required

Onsite/Remote

Onsite

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 From the View menu, choose Go to Network View.

Step 3 Click the Circuit tab.

Step 4 Set the circuit and circuit ports to the maintenance state (OOS-MT). Take note of the original state because you will return the circuit to that state later.

a. Click the circuit you want to test then choose Circuits > Set Circuit State from the Tools menu.

b. On the Set Circuit State dialog box, choose OOS-MT from the Target State pull-down menu.

c. Check the Apply to drop ports check box.

d. Click Apply.

Step 5 Attach loopback cables to the circuit destination card.

a. Verify the integrity of the loopback cable by looping the test set transmit (Tx) connector to the test set receive (Rx) connector. If the test set does not run error-free, check the cable for damage and check the test set to make sure it is set up correctly before going to Step b.

b. Attach the loopback cable to the port you are testing. Connect the transmit (Tx) connector to the receive (Rx) connector of the port.

Step 6 Attach loopback cables to the circuit source node.

a. Verify the integrity of loopback cable by looping the test set transmit (Tx) connector to the test set receive (Rx) connector. If the test set does not run error-free, check the cable for damage and check the test set to make sure it is set up correctly before going to Step b.

b. Attach the loopback cable to the port you are testing. Connect the test set to the circuit source port: (transmit (Tx) port of the test set to the circuit receive (Rx) port; test set receive (Rx) port to the circuit transmit (Tx) port.

Step 7 Configure the test set for the ONS 15454 SDH card that is the source of the circuit you are testing:

VC4 or VC4-nc—If you are testing a VC4 circuit or a VC4-nc circuit on an STM-N card, you must have a direct optical interface into the ONS 15454 SDH. Set the test set for STM-N. For information about configuring your test set, consult your test set user guide.

VC3—If you are testing a clear channel E3/DS3I, you must have a patch panel or a direct E3/DS3I interface into the ONS 15454 SDH. Set the test set for clear channel E3/DS3I. For information about configuring your test set, consult your test set user guide.

VC12—If you are testing an E1, you must have a patch panel or a direct E1 interface to the ONS 15454 SDH. Set the test set for E1. For information about configuring your test set, consult your test set user guide.

Step 8 Verify that the test set displays a clean signal. If a clean signal is not displayed, repeat Steps 1 through 7 to make sure the test set and cabling is configured correctly.

Step 9 Inject errors from the test set. Verify that the errors display at the source and destination nodes.

Step 10 Clear the PMs for the ports that you tested. See the "DLP-D130 Clear Selected PM Counts" task on page 8-18 for instructions.

Step 11 Put the circuit and circuit ports back to the state they were in at the beginning of the test:

a. Click the circuit you want to test then choose Circuits > Set Circuit State from the Tools menu.

b. On the Set Circuit State dialog box, choose IS (in service), OOS (out of service) or OOS-AINS (auto in service) from the Target State pull-down menu.

c. Check the Apply to drop ports check box.

d. Click Apply.

Step 12 Perform the protection switch test appropriate to the SDH topology:

For SNCP rings, complete the "DLP-D94 SNCP Protection Switching Test" task on page 5-36

For MS-SPRings complete the "DLP-D91 MS-SPRing Switch Test" task on page 5-24.

Step 13 Perform a bit error rate test (BERT) for 12 hours or follow your site requirements for length of time. For information about configuring your test set for BERT, see your test set user guide.

Step 14 After the BERT is complete, print the results or save them to a disk for future reference. For information about printing or saving test results see your test set user guide.

Stop. You have completed this procedure.


NTP-D188 Create an Automatically Routed High-Order Circuit

Purpose

This procedure creates an automatically-routed bidirectional or unidirectional high-order circuit, including STM-1 and concatenated STM4-2c, STM4-3c, STM4-4c, STM4-8c, STM4-16c, and STM4-64c speeds.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box (Figure 6-12), complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the high-order circuit size: STM-1, STM4-2c, STM4-3c, STM4-4c, STM4-8c, STM4-16c, or STM4-64c.

Bidirectional—Leave checked for this circuit (default).

Number of Circuits—Type the number of high-order circuits you want to create. The default is 1. If you are creating multiple circuits with the same source and destination, you can use auto-ranging to create the circuits automatically.

Auto-ranged—This check box is automatically selected when you enter more than 1 in the Number of Circuits field. Leave this check box selected if you are creating multiple high-order circuits with the same source and destination and you want CTC to create the circuits automatically. Deselect the box if you do not want CTC to create the circuits automatically.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed to protected drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards as source and destination choices.

Figure 6-12 Setting Circuit Attributes for an High-Order Circuit

Step 6 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 7 Click Next.

Step 8 Complete the "DLP-D97 Provision a High-Order Circuit Source and Destination" task for the high-order circuit you are creating.

Step 9 Under Circuit Routing Preferences (Figure 6-13), choose Route Automatically. Two options are available; choose either, both, or none based on your preferences.

Using Required Nodes/Spans—Choose this check box to specify nodes and spans to include or exclude in the CTC-generated circuit route.

Review Route Before Creation—Choose this check box to review and edit the circuit route before the circuit is created.

Step 10 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 11. CTC creates a fully-protected circuit route based on the path diversity option you choose. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 13.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, then continue with Step 13.

Step 11 If you selected Fully Protected Path, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Figure 6-13 Setting Circuit Routing Preferences for a High-Order Circuit

.

Step 12 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 13 If you selected Using Required Nodes/Spans in Step 9, complete the following substeps. If not, continue with Step 14:

a. Click Next.

b. Under Circuit Route Constraints, click a node or span on the circuit map.

c. Click Include to include the node or span in the circuit, or click Exclude to exclude the node or span from the circuit. The order in which you choose included nodes and spans is the order in which the circuit will be routed. Click spans twice to change the circuit direction.

d. Repeat Step c. for each node or span you wish to include or exclude.

e. Review the circuit route. To change the circuit routing order, choose a node under the Required Nodes/Lines or Excluded Notes Links lists, then click the Up or Down buttons to change the circuit routing order. Click Remove to remove a node or span.

Step 14 If you selected Review Route Before Creation in Step 9, complete the following substeps; otherwise, continue with Step 15:

a. Click Next.

b. Review the circuit route. To add or delete a circuit span, choose a node on the circuit route. Blue arrows show the circuit route. Green arrows indicate spans that you can add. Click a span arrowhead, then click Include to include the span or Remove to remove the span.

c. If the provisioned circuit does not reflect the routing and configuration you want, click Back to verify and change circuit information. If the circuit needs to be routed to a different path, see the "189 Create a Manually Routed High-Order Circuit" procedure to assign the circuit route yourself.

Step 15 Click Finish. One of the following occurs, based on the circuit properties you provisioned in the Circuit Creation dialog box:

If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC automatically creates the number of circuits entered in Number of Circuits. If auto ranging cannot complete all the circuits, for example, because sequential ports are unavailable on the source or destination, a dialog box is displayed. Set the new source or destination for the remaining circuits, then click Finish to continue auto ranging.

If you entered more than 1 in Number of Circuits and did not choose Auto-ranged, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat Steps Step 5 through 15 for each additional circuit.

After completing the circuit(s), CTC displays the Circuits window.

Step 16 On the Circuits window, verify that the circuit(s) you created appear in the circuits list.

Step 17 Complete the "62 Test High-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


NTP-D189 Create a Manually Routed High-Order Circuit

Purpose

This procedure creates a manually routed, bidirectional or unidirectional high-order circuit, including including STM-1 and concatenated STM4-2c, STM4-3c, STM4-4c, STM4-8c, STM4-16c, and STM4-64c speeds.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the high-order circuit size: STM-1, STM4-2c, STM4-3c, STM4-4c, STM4-8c, STM4-16c, or STM4-64c.

Bidirectional—Leave checked for this circuit.

Number of Circuits—Type the number of high-order circuits you want to create. The default is 1.

Auto-ranged—Applies to automatically-routed circuits only. If you entered more than 1 in Number of Circuits, deselect this check box. (The check box is unavailable if only one circuit is entered in Number of Circuits.)

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed to protect drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards as source and destination choices.

Step 5 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 6 Click Next.

Step 7 Complete the "DLP-D97 Provision a High-Order Circuit Source and Destination" task for the high-order circuit you are creating.

Step 8 Under Circuit Routing Preferences (Figure 6-13), deselect Route Automatically.

Step 9 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 10.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 12.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, then continue with Step 12.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 10 If you selected Fully Protected Path, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.

Step 11 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 12 Click Next. Under Route Review and Edit, node icons are displayed so you can route the circuit manually.

Step 13 Complete the "DLP-D98 Provision a High-Order Circuit Route" task.

Step 14 Click Finish. If the path does not meet the specified path diversity requirement, CTC displays an error message and allows you to change the circuit path. If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box is displayed after the circuit is created so you can create the remaining circuits. Repeat Steps 4 through 14 for each additional circuit.

Step 15 When all the circuits are created, CTC displays the main Circuits window. Verify that the circuit(s) you created appear in the window.

Step 16 Complete the "62 Test High-Order Circuits" procedure.

Stop. You have completed this procedure.


NTP-D190 Create a Unidirectional High-Order Circuit with Multiple Drops

Purpose

This procedure creates a unidirectional STM-N circuit with multiple traffic drops (circuit destinations).

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into the node where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the high-order circuit size: STM-1, STM4-2c, STM4-3c, STM4-4c, STM4-8c, STM4-16c, or STM4-64c.

Bidirectional—Deselect this check box for this circuit.

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable when the Number of Circuits field is 1.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Select this check box if you want the circuit routed to protect drops only, that is, to ONS 15454 SDH cards that are in 1:1, 1:N, or 1+1 protection. If you select this check box, CTC displays only protected cards as source and destination choices.

Step 6 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 7 Click Next.

Step 8 Complete the "DLP-D97 Provision a High-Order Circuit Source and Destination" task for the circuit you are creating.

Step 9 Deselect Route Automatically. When Route Automatically is not selected, Using Required Nodes/Spans and Review Route Before Circuit Creation are unavailable.

Step 10 Set the circuit path protection:

To route the circuit on a protected path, leave Fully Protected Path checked and continue with Step 11. Fully-protected paths may or may not have SNCP path segments (with primary and alternate paths), and the path diversity options apply only to SNCP path segments, if any exist.

To create an unprotected circuit, uncheck Fully Protected Path and continue with Step 13.

To route the circuit on an MS-SPRing protection channel, if available, uncheck Fully Protected Path, check Protection Channel Access, click Yes on the Warning dialog box, then continue with Step 13.


Caution Circuits routed on MS-SPRing protection channels are not protected and are preempted during MS-SPRing switches.

Step 11 If you selected Fully Protected Path, choose one of the following:

Nodal Diversity Required—Ensures that the primary and alternate paths within the SNCP ring portions of the complete circuit path are nodally diverse.

Nodal Diversity Desired—Specifies that node diversity is preferred, but if node diversity is not possible, CTC creates fiber-diverse paths for the SNCP ring portion of the complete circuit path.

Link Diversity Only—Specifies that only fiber-diverse primary and alternate paths for SNCP ring portions of the complete circuit path are needed. The paths may be node-diverse, but CTC does not check for node diversity.


Note For manually-routed circuits, CTC checks your manually-provisioned path against the path diversity option you choose. If the path does not meet the path diversity requirement that is specified, CTC displays an error message.


Step 12 If you selected Fully Protected Path and the circuit will be routed on an SNCP dual ring interconnect (DRI), click the Dual Ring Interconnect check box.

Step 13 Click Next. Under Route Review and Edit, node icons are displayed so you can route the circuit manually. The green arrows pointing from the selected node to other network nodes indicate spans that are available for routing the circuit.

Step 14 Complete the "DLP-D98 Provision a High-Order Circuit Route" task.

Step 15 Click Finish. After completing the circuit, CTC displays the Circuits window.

Step 16 On the Circuits window, click the circuit that you want to route to multiple drops. The Delete, Edit, and Search buttons become active.

Step 17 Click Edit. The Edit Circuit window is displayed with the General tab selected. Nodes in the DCC network are displayed graphically. Circuit source and destination information appears under the source and destination nodes. To display a detailed view of the circuit, click Show Detailed Map. You can rearrange the node icons by pressing Ctrl while you drag and drop the icon to the new location.

Step 18 On the Edit Circuit dialog box, click the Drops tab. A list of existing drops is displayed.

Step 19 Click Create.

Step 20 On the Define New Drop dialog box, define the new drop:

a. Node—Choose the target node for the circuit drop.

b. Slot—Choose the target card and slot.

c. Port, VC4—Choose the port and/or VC4 from the Port and VC4 pull-down menus. The choice in these menus depends on the card selected in Step b. See Table 6-2 for a list of options.

d. The routing preferences for the new drop will match those of the original circuit. However, you can modify the following:

If the original circuit was routed on a protected path, you can change the nodal diversity options: Required, Desired, Don't Care; Link Diverse only. See Step 11 for descriptions.

If the original circuit was not routed on a protected path, the Protection Channel Access options is available. See Step 10 for a description of the PCA option.

e. Click OK. The new drop appears in the Drops list.

Step 21 If you need to create additional drops on the circuit, repeat Steps 18 through 20.

Step 22 Click Close. The Circuits window appears.

Step 23 Verify that the new drops are displayed under the Destination column for the circuit you edited. If they do not appear, repeat Steps 19 through 22 making sure all options are provisioned correctly.

Step 24 Complete the "62 Test High-Order Circuits" procedure.

Stop. You have completed this procedure.


DLP-D97 Provision a High-Order Circuit Source and Destination

Purpose

This task provisions the source and destination for a high-order optical circuit.

Tools/Equipment

None

Prerequisite Procedures

Perform this task during one of the following procedures:

188 Create an Automatically Routed High-Order Circuit

189 Create a Manually Routed High-Order Circuit

190 Create a Unidirectional High-Order Circuit with Multiple Drops

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 From the Node pull-down menu, choose the node where the circuit will originate.

Step 2 From the Slot pull-down menu, choose the slot containing the high-order card where the circuit originates. (If a card's capacity is fully utilized, it does not appear in the menu.)

Step 3 Depending on the circuit origination card, choose the source port and/or VC-4 from the Port and VC-4 sub-menus. The Port menu is only available if the card has multiple ports. VC-4s are not displayed if they are already in use by other circuits.


Note The VC4s that display depend on the card, circuit size, and protection scheme. For example, if you create an VC4 circuit on an STM-4 card in an SNCP ring, only four VC4s are available. If you create an VC4 circuit on an STM-4 card in an MS-SPRing, two VC4s are available because of the MS-SPRing protection characteristics.


Step 4 If you need to create a secondary source, for example, an SNCP ring bridge/selector circuit entry point in a multivendor SNCP ring, click Use Secondary Source and repeat Steps 1 through 3 to define the secondary source.

Step 5 Click Next.

Step 6 From the Node pull-down menu, choose the destination node.

Step 7 From the Slot pull-down menu, choose the slot containing the optical card where the circuit will terminate (destination card). (If a card's capacity is fully utilized, the card does not appear in the menu.)

Step 8 Depending on the card selected in Step 2, choose the destination port and/or VC-4 from the Port and VC-4 sub-menus. The Port menu is available only if the card has multiple ports. The VC-4s that display depend on the card, circuit size, and protection scheme.

Step 9 If you need to create a secondary destination, for example, an SNCP ring bridge/selector circuit entry point in a multivendor SNCP ring, click Use Secondary Destination and repeat Steps 6 through 8 to define the secondary destination.

Step 10 Click Next.

Step 11 Return to your originating procedure (NTP).


DLP-D98 Provision a High-Order Circuit Route

Purpose

This task provisions a high-order circuit route for manually-routed circuits.

Tools/Equipment

None

Prerequisite Procedures

Perform this task during one of the following procedures:

188 Create an Automatically Routed High-Order Circuit

189 Create a Manually Routed High-Order Circuit

190 Create a Unidirectional High-Order Circuit with Multiple Drops

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 On the Circuit Creation wizard under Route Review and Edit, click the source node icon if it is not already selected.

Step 2 Starting with a span on the source node, click the arrow of the span you want the circuit to travel. The arrow turns white. Under Selected Span, the From and To fields display span information. The source VC-4 is displayed. Figure 6-14 shows an example.

Figure 6-14 Manually Routing a STM-N Circuit

Step 3 If you want to change the source VC-4, adjust the Source VC4 field; otherwise, continue with Step 4.

Step 4 Click Add Span. The span is added to the Included Spans list and the span arrow turns blue.

Step 5 Repeat Steps 2 through 4 until the circuit is provisioned from the source to the destination node through all intermediary nodes. If Fully Protect Path is checked on the Circuit Routing Preferences panel, you must:

Add two spans for all SNCP ring or unprotected portions of the circuit route from the source to the destination

Add one span for all MS-SPRing or 1+1 portions of route from the source to the destination

Step 6 Return to your originating procedure (NTP).


NTP-D62 Test High-Order Circuits

Purpose

This procedure tests a high-order circuit.

Tools/Equipment

Test set capable of optical speeds, appropriate fibers, and attenuators

Prerequisite Procedures

This procedure assumes you completed facility loopback tests to test the fibers and cables from the source and destination ONS 15454 SDHs to the fiber distribution panel or the DSX and one of following circuit procedures:

188 Create an Automatically Routed High-Order Circuit

189 Create a Manually Routed High-Order Circuit

Required/As Needed

Required

Onsite/Remote

Onsite

Security Level

Provisioning or higher



Step 1 Log into the node where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions.

Step 2 From the View menu, choose Go to Network View.

Step 3 Click the Circuits tab.

Step 4 Set the circuit and circuit ports to Out of Service-Maintenance (OOS_MT):

a. Click the circuit you want to test.

b. From the Tools menu, choose Circuits > Set Circuit State.

c. On the Set Circuit State dialog box, choose OOS-MT from the Target State pull-down menu.

d. If unchecked, check the Apply to drop ports check box.

e. Click Apply.

Step 5 Set up the patch cable at the destination node:

a. Test the patch cable by connecting one end to the test set transmit (Tx) port and the other end to the test receive (Rx) port. If the test set does not run error-free, check the cable for damage and check the test set to make sure it is set up correctly.

b. Install the loopback cable on the port you are testing between the transmit (Tx) and receive (Rx) connections.

Step 6 Set up the loopback cable at the source node:

a. Test the loopback cable by connecting one end to the test set transmit (Tx) port and the other end to the test receive (Rx) port. If the test set does not run error-free, check the cable for damage and check the test set to make sure it is set up correctly.

b. At the source node attach the loopback cable to the port you are testing. Connect the test set to the circuit source port: transmit (Tx) port of the test set to the circuit receive (Rx) port; test set receive (Rx) port to the circuit transmit (Tx) port.

Step 7 Configure the test set for the source ONS 15454 SDH card:

STM-1 cards—You will test a VC4 circuit on one of the STM-1 ports. Configure the test set for an STM-1 port.

STM-4 cards—You will test either a VC4-4c (the "c" denotes concatenated) or a muxed VC4-4. If you are testing a VC4-4c, configure the test set for a VC4-4c. If you are testing a muxed VC4-4, configure the test set for a muxed VC4-4 and choose the E3, DS3I, or E1 you will test. For information about configuring your test set, consult your test set user guide.

STM-16 cards—You will test either a VC4-16c or a muxed VC4-16. If you are testing a VC4-16c configure the test set for a VC4-16c. If you are testing a muxed VC4-16, configure the test set for a muxed VC4-16 and choose the E3, DS3I, or E1 you will test. For information about configuring your test set, consult your test set user guide.

STM-64 cards—You will test a VC4-64c or a muxed VC4-64. If you are testing a VC4-64c configure the test set for a VC4-64c. If you are testing a muxed VC4-64, configure the test set for a muxed VC4-64 and choose the E3, DS3I, or E1 you will test. For information about configuring your test set, consult your test set user guide.

Step 8 Verify that the test set displays a clean signal. If a clean signal is not displayed, repeat Steps 1 through 7 to make sure you have configured the test set and cabling correctly.

Step 9 Inject errors from the test set. Verify that the errors display at the source and destination nodes.

Step 10 Clear the PMs for the ports that you tested. See the "DLP-D130 Clear Selected PM Counts" task on page 8-18 for instructions.

Step 11 Perform protection switch testing appropriate to the SDH topology:

For SNCP rings, see the "DLP-D94 SNCP Protection Switching Test" task on page 5-36.

For MS-SPRings see the "DLP-D91 MS-SPRing Switch Test" task on page 5-24.

Step 12 Perform a bit error rate test (BERT) for 12 hours or follow your site requirements for length of time. For information about configuring your test set for BERT, see your test set user guide.

Step 13 After the BERT is complete, print the results or save them to a disk for future reference. For information about printing or saving test results see your test set user guide.

Step 14 Change the circuit and circuit ports from OOS_MT to their previous service states:

a. Click the circuit you want to test, then,from the Tools menu choose Circuits > Set Circuit State.

b. On the Set Circuit State dialog box, choose IS (in service), OOS (out of service), or OOS-AINS (auto inservice), from the Target State pull-down menu.

c. If unchecked, check the Apply to drop ports check box.

d. Click Apply.

Stop. You have completed this procedure.


NTP-D139 Create a Half Circuit on an MS-SPRing or 1+1 Node

Purpose

This procedure creates a low-order or high-order circuit from a drop card to an STM-N trunk (span) card on the same node in an MS-SPRing or 1+1 topology.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the half circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—For low-order circuits, choose VC_LO_PATH_CIRCUIT. For high-order circuits, choose VC_HO_PATH_CIRCUIT. VC4 cross-connects will carry the circuit across the ONS 15454 SDH network.

Size—For high-order circuits, choose the VC4. For low-order circuits, choose VC12 or VC3.

Bidirectional—Leave checked for this circuit (default).

Number of Circuits—Type the number of circuits you want to create. The default is 1.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Deselect the box.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Select this check box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Deselect this check box if it is selected.

Step 6 Click Next.

Step 7 Complete the "DLP-D311 Provision a Half Circuit Source and Destination - MS-SPRing and 1+1" task.

Step 8 Click Finish. One of the following results occurs, depending on the circuit properties you chose in the Circuit Creation dialog box:

If you entered more than 1 in Number of Circuits and selected Auto-ranged, CTC automatically creates the number of circuits entered in Number of Circuits. If auto ranging cannot complete all the circuits, for example, because sequential ports are unavailable at the source or destination, a dialog box is displayed. Set the new source or destination for the remaining circuits, then click Finish to continue auto ranging.

If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

After completing the circuit(s), CTC displays the Circuits window.

Step 9 On the Circuits window, verify that the new circuits appear in the circuits list.

Stop. You have completed this procedure.


NTP-D140 Create a Half Circuit on an SNCP ring Node

Purpose

This procedure creates a low-order or high-order circuit from a drop card to an STM-N trunk (span) card on the same SNCP ring node.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If not, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab, then click Create.

Step 5 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—For low-order circuits, choose VC_LO_PATH_CIRCUIT. For high-order circuits, choose VC_HO_PATH_CIRCUIT. VC4 cross-connects will carry the circuit across the ONS 15454 SDH network.

Size—For high-order circuits, choose the VC4. For low-order circuits, choose VC12 or VC3.

Bidirectional—Leave checked for this circuit (default).

Number of Circuits—Type the number of circuits you want to create. The default is 1.

Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of Circuits field. Deselect the box.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Check this box if you want to apply the state chosen in the State field to the circuit source and destination ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Deselect this check box if it is selected.

Step 6 Set the SNCP path selectors. See the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 7 Click Next.

Step 8 Click Finish. One of the following results occurs, depending on the circuit properties you chose in the Circuit Creation dialog box:

If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC automatically creates the number of circuits entered in the Number of Circuits field. If auto ranging cannot complete all the circuits, for example, because sequential ports are unavailable at the source or destination, a dialog box is displayed. Set the new source or destination for the remaining circuits, then click Finish to continue auto ranging.

If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the Circuit Creation dialog box is displayed so you can create the remaining circuits. Repeat this procedure for each additional circuit.

After completing the circuit(s), CTC displays the Circuits window.

Step 9 On the Circuits window, verify that the new circuits appear in the circuits list.

Step 10 Complete the "135 Test Low-Order Circuits" procedure. Skip this step if you built a test circuit.

Stop. You have completed this procedure.


DLP-D311 Provision a Half Circuit Source and Destination - MS-SPRing and 1+1

Purpose

This task provisions a half circuit source and destination.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during the 139 Create a Half Circuit on an MS-SPRing or 1+1 Node procedure.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 From the Node pull-down menu, choose the node that will contain the half circuit.

Step 2 From the Slot pull-down menu, choose the slot containing the card where the circuit will originate.

Step 3 From the Port pull-down menu, choose the port where the circuit will originate. This field may not be available, depending on the card chosen in Step 2.

Step 4 Complete one of the following:

For low-order VC12 circuits, choose the VC4, TUG3, TUG2, and VC12.

For low-order VC3 circuits, choose the VC4, and VC3.

For high-order circuits, choose the VC4.

Step 5 Click Next.

Step 6 From the Node pull-down menu, choose the node chosen in Step 1.

Step 7 From the Slot pull-down menu, choose the STM-N card to map the low-order VC3 or VC12 circuit for optical transport or to map the VC4 circuit to an STM.

Step 8 Choose the destination STS or VT from the sub-menus that display.

Step 9 Return to your originating procedure (NTP).


DLP-D312 Provision a Half Circuit Source and Destination - SNCP Ring

Purpose

This task provisions a half circuit source and destination.

Tools/Equipment

None

Prerequisite Procedures

You perform this task during the 140 Create a Half Circuit on an SNCP ring Node procedure.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 From the Node pull-down menu, choose the node that will contain the half circuit.

Step 2 From the Slot pull-down menu, choose the slot containing the card where the circuit will originate.

Step 3 From the Port pull-down menu, choose the port where the circuit will originate. This field may not be available, depending on the card chosen in Step 2.

Step 4 Complete one of the following:

For low-order VC12 circuits, choose the VC4, TUG3, TUG2, and VC12.

For low-order VC3 circuits, choose the VC4 and VC3.

For high-order circuits, choose the VC4.

Step 5 Click Next.

Step 6 From the Node pull-down menu, choose the node chosen in Step 1.

Step 7 From the Slot pull-down menu, choose the STM-N card to map the low-order VC3 or VC12 circuit for optical transport or to map the VC4 circuit to an STM.

Step 8 Click Next.

Step 9 Choose the destination VC4, VC3, TUG3, TUG2, and VC12 from the sub-menus that display.

Step 10 Click Use Secondary Destination and repeat Steps 1 through 9.

Step 11 Return to your originating procedure (NTP).


NTP-D191 Create an E-Series EtherSwitch Circuit (Multicard or Single-Card Mode)

Purpose

This procedure creates a multicard or single-card EtherSwitch circuit. It does not apply to E-Series cards in port-mapped mode. To create a port-mapped mode circuit, see 192 Create a Circuit for an E-Series Card in Port-Mapped Mode.

Tools/Equipment

E-Series Ethernet cards (E100T-G or E1000-2-G) must be installed at each end of the Ethernet circuit.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 If a high number of VLANs is already used by the network, complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available (you will create a VLAN during each circuit creation task).

Step 4 Verify that the circuit source and destination Ethernet cards are provisioned for the mode of the circuit you will create, either multicard or single-card. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 5 Provision and enable the Ethernet ports. See "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 6 From the View menu, choose Go to Network View.

Step 7 Click the Circuits tab, then click Create.


Caution A TCC+/TCC2 card reset disrupts single-card and multicard Etherswitch circuits for 45 seconds to two minutes. During this time a spanning tree topology is created by the newly activated TCC+/TCC2 card.

Step 8 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the circuit size. Valid circuit sizes for an Ethernet Multicard circuit are VC4 and VC4-2c. Valid circuit sizes for an Ethernet Single-card circuit are VC4, VC4-2c and VC4-4c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose IS (in service). Ethergroup circuits are always in service.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave the default unchanged (unchecked).

Step 9 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 10 Click Next.

Step 11 Provision the circuit source:

a. From the Node pull-down menu, choose one of the EtherSwitch circuit endpoint nodes. (Either end node can be the EtherSwitch circuit source.)

b. From the Slot pull-down menu, choose one of the following:

If you are building a Multicard EtherSwitch circuit, choose Ethergroup.

If you are building a Single-card EtherSwitch circuit, choose the Ethernet card where you enabled the single-card EtherSwitch.

Step 12 Click Next.

Step 13 Provision the circuit destination:

a. From the Node pull-down menu, choose the second EtherSwitch circuit endpoint node.

b. From the Slot pull-down menu, choose one of the following:

If you are building a Multicard EtherSwitch circuit, choose Ethergroup.

If you are building a Single-card EtherSwitch circuit, choose the Ethernet card where you enabled the single-card EtherSwitch.

Step 14 Click Next.

Step 15 Under Circuit VLAN Selection, click New VLAN. If the desired VLAN already exists, continue with Step 18.

Step 16 In the New VLAN dialog box, complete the following:

VLAN Name—Assign an easily-identifiable name to your VLAN.

VLAN ID—Assign a VLAN ID. The VLAN ID should be the next available number between 2 and 4093 that is not already assigned to an existing VLAN. Each ONS 15454 SDH network supports a maximum of 509 user-provisionable VLANs.

Step 17 Click OK.

Step 18 Under Circuit VLAN Selection, highlight the VLAN name and click the arrow button (>>) to move the available VLAN(s) to the Circuit VLANs column.

Step 19 If you are building a single-card EtherSwitch circuit and want to disable spanning tree protection on this circuit, uncheck the Enable Spanning Tree check box and click OK on the Disabling Spanning Tree dialog box. The Enable Spanning Tree box will remain checked or unchecked for the creation of the next single-card, point-to-point Ethernet circuit.


Caution Disabling spanning tree protection increases the likelihood of logic loops on an Ethernet network.


Caution Turning off spanning tree on a circuit-by-circuit basis means that the ONS 15454 SDH is no longer protecting the Ethernet circuit and that the circuit must be protected by another mechanism in the Ethernet network.


Caution Multiple circuits with spanning tree protection enabled will incur blocking if the circuits traverse the same E-series card and use the same VLAN.


Note You can disable or enable spanning tree protection on a circuit-by-circuit basis only for single-card, point-to-point Ethernet circuits. Other E-series Ethernet configurations disable or enable spanning tree on a port-by-port basis.


Step 20 Click Next.

Step 21 Confirm that the following information about the circuit is correct:

Circuit name

Circuit type

Circuit size

ONS 15454 SDH circuit nodes

Step 22 Click Finish.

Step 23 Complete the "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 24 Complete the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task.

Stop. You have completed this procedure.


NTP-D192 Create a Circuit for an E-Series Card in Port-Mapped Mode

Purpose

This procedure creates an E-Series point-to-point SDH circuit with an E-Series card in port-mapped mode.

Tools/Equipment

An E-Series Ethernet card must be installed at each end of the circuit and configured in port-mapped mode.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 Provision the Ethernet cards that will carry the circuit for port-mapped mode. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 4 Provision and enable the Ethernet ports. See "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 5 From the View menu, choose Go to Network View.

Step 6 Click the Circuits tab and click Create.

Step 7 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the circuit size. Valid circuit sizes for an E-Series in port-mapped mode are VC4, VC4-2c and VC4-4c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Select this checkbox if you want to apply the state chosen in the State field (IS or OOS-MT only) to the Ethernet circuit source and destination ports. You cannot apply OOS-AINS to E-Series Ethernet card ports. CTC will apply the circuit state to the ports only if the circuit bandwidth is the same as the port bandwidth or, if the port bandwidth is larger than the circuit, the circuit must be the first circuit to use the drop port. If not, a Warning dialog box displays the ports where the circuit state could not be applied. If the box is unchecked, CTC will not change the state of the source and destination ports.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Auto-ranged—Unavailable.

Protected Drops—Leave the default unchanged (unchecked).

Step 8 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 9 Click Next.

Step 10 Provision the circuit source:

a. From the Node pull-down menu, choose the circuit source node. Either end node can be the point-to-point circuit source.

b. From the Slot pull-down menu, choose the slot containing the E-Series card that you will use for one end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 11 Click Next.

Step 12 Provision the circuit destination:

a. From the Node pull-down menu, choose the circuit destination node.

b. From the Slot pull-down menu, choose the slot containing the E-Series card that you will use for other end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 13 Click Next. The Circuits window appears.

Step 14 Confirm that the following circuit information is correct:

Circuit name

Circuit type

Circuit size

ONS 15454 SDH circuit nodes

Step 15 Click Finish.

Step 16 Complete the "146 Test E-Series Circuits" procedure.

Stop. You have completed this procedure.


NTP-D142 Create an E-Series Shared Packet Ring Ethernet Circuit

Purpose

This procedure creates a shared packet ring Ethernet circuit. It does not apply to E-Series cards in Port-mapped mode.

Tools/Equipment

E-Series Ethernet cards must be installed at both Ethernet circuit endpoint nodes.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 If a high number of VLANs is already used by the system, complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available (you will create a VLAN during each circuit creation task).

Step 4 Verify that the Ethernet cards that will carry the circuit are provisioned for Multi-card EtherSwitch Group. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 5 Provision and enable the Ethernet ports. See "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 6 From the View menu, choose Go to Network View.

Step 7 Click the Circuits tab and click Create.

Step 8 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the circuit size. Valid shared packet ring circuit sizes are VC4 and VC4-2c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose IS (in service). Ethergroup circuits are always in service.

Apply to drop ports—Uncheck this box; states cannot be applied to E-Series ports.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave the default unchanged (unchecked).

Step 9 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 10 Click Next.

Step 11 Provision the circuit source:

a. From the Node pull-down menu, choose one of the shared packet ring circuit endpoint nodes. (Either end node can be the shared packet ring circuit source.)

b. From the Slot pull-down menu, choose Ethergroup.

Step 12 Click Next.

Step 13 Provision the circuit destination:

a. From the Node pull-down menu, choose the second shared packet ring circuit endpoint node.

b. From the Slot pull-down menu, choose Ethergroup.

Step 14 Click Next.

Step 15 Review the VLANs listed under Available VLANs. If the VLAN you want to use is displayed, continue with Step 16. If you need to create a new VLAN, complete the following steps:

a. Click the New VLAN button.

b. On the New VLAN dialog box, complete the following:

VLAN Name—Assign an easily-identifiable name to your VLAN.

VLAN ID—Assign a VLAN ID. The VLAN ID should be the next available number between 2 and 4093 that is not already assigned to an existing VLAN. Each ONS 15454 SDH network supports a maximum of 509 user-provisionable VLANs.

c. Click OK.

Step 16 In the Available VLANs column, click the VLAN you want to use and click the arrow button (>>) to move the VLAN to the Circuit VLANs column.


Note Moving the VLAN from Available VLANs to Circuit VLANs forces all the VLAN traffic to use the shared packet ring you are creating.


Step 17 Click Next.

Step 18 Under Circuit Routing Preferences, uncheck the Route Automatically check box and click Next.

Step 19 Under Route Review and Edit, click the source node, then click a span (green arrow) leading away from the source node.

The span turns white.

Step 20 Click Add Span.

The span turns blue. CTC adds the span to the Included Spans list.

Step 21 Click the node at the end of the blue span.

Step 22 Click the green span attached to the node you clicked in Step 21.

The span turns white.

Step 23 Click Add Span.

The span turns blue.

Step 24 Repeat Steps 20 through 23 for every node in the ring.

Step 25 Verify that the new circuit is correctly configured in the Route Review and Edit. If the circuit information is not correct, click the Back button and repeat the procedure with the correct information.


Note If the circuit is incorrect, you can also click Finish, delete the completed circuit, and begin the procedure again.


Step 26 Click Finish.

Step 27 Complete the "DLP-D220 Provision E-Series Ethernet Ports" task for each node that carries the circuit.

Step 28 Complete the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task for each node that carries the circuit.

Step 29 Complete the "146 Test E-Series Circuits" procedure.

Stop. You have completed this procedure.


NTP-D143 Create an E-Series Hub and Spoke Ethernet Configuration

Purpose

This procedure creates a hub and spoke Ethernet configuration, which is made up of multiple circuits that share a common endpoint. It does not apply to E-Series cards in port-mapped mode.

Tools/Equipment

E-Series Ethernet cards (E100T-G or E1000-2-G) must be installed at all Ethernet circuit endpoint nodes.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into the hub node (the common endpoint). See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 Complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available (you will create a VLAN during each circuit creation task).

Step 4 Display the node view.

Step 5 Verify that the Ethernet card that will carry the hub and spoke circuit is provisioned for Singlecard EtherSwitch Group. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 6 Provision and enable the Ethernet ports. See "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 7 Log into the spoke node and repeat Steps 4 and 5 for the Ethernet card in the other circuit endpoint. (You only need to verify that the hub node is provisioned for Singlecard EtherSwitch once.)

Step 8 Click the Circuits tab and click Create.

Step 9 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the circuit size. Valid circuit sizes for a single-card Etherswitch circuit are VC4, VC4-2c, and VC4-4c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose IS (in service). Ethergroup circuits are always in service.

Apply to drop ports—Uncheck this box; states cannot be applied to E-Series ports.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave the default unchanged (uchecked).

Step 10 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 11 Click Next.

Step 12 Provision the circuit source:

a. From the Node pull-down menu, choose the hub node.

b. From the Slot pull-down menu, choose the Ethernet card where you enabled the single-card EtherSwitch.

Step 13 Click Next.

Step 14 Provision the circuit destination:

a. From the Node pull-down menu, choose an EtherSwitch circuit endpoint node.

b. From the Slot pull-down menu, choose the Ethernet card where you enabled the single-card EtherSwitch.

Step 15 Click Next.

Step 16 Review the VLANs listed under Available VLANs. If the VLAN you want to use is displayed, continue with Step 18. If you need to create a new VLAN, complete the following steps:

a. Click the New VLAN button.

b. On the New VLAN dialog box, complete the following:

VLAN Name—Assign an easily-identifiable name to your VLAN.

VLAN ID—Assign a VLAN ID. The VLAN ID should be the next available number between 2 and 4093 that is not already assigned to an existing VLAN. Each ONS 15454 SDH network supports a maximum of 509 user-provisionable VLANs.

c. Click OK.

Step 17 In the Available VLANs column, click the VLAN you want to use and click the arrow button (>>) to move the VLAN to the Circuit VLANs column.


Note Moving the VLAN from Available VLANs to Circuit VLANs forces all the VLAN traffic to use the shared packet ring you are creating.


Step 18 Click Next.

Step 19 Confirm that the following information about the hub and spoke circuit is correct:

Circuit name

Circuit type

Circuit size

VLAN names

ONS 15454 SDH circuit nodes

If the circuit information is not correct, click the Back button and repeat the procedure with the correct information.


Note You can also click Finish, delete the completed circuit, and start the procedure from the beginning.


Step 20 Click Finish.

Step 21 Complete the "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 22 Complete the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task.

Step 23 Complete the "146 Test E-Series Circuits" procedure.

Step 24 To create additional circuits ("spokes"):

a. Complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available for the circuit destination node.

b. Repeat Steps 4 through 23.

Stop. You have completed this procedure.


NTP-D144 Create an E-Series Single-Card EtherSwitch Manual Cross-Connect

Purpose

This procedure manually creates a Single-Card EtherSwitch cross-connect between E-Series Ethernet cards and an STM-N cards connected to non-ONS equipment.

Tools/Equipment

E-Series Ethernet cards (E100T-G or E1000-2-G) must be installed at the circuit source node.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note In this procedure, cross-connect refers to a circuit connection created within the same node between the Ethernet card and an STM-N card connected to third-party equipment. You create cross-connects at the source and destination nodes so an Ethernet circuit can be routed from source to destination across third-party equipment.



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 If a high number of VLANs is already used by the network, complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available (you will create a VLAN during each circuit creation task).

Step 4 On the node view, double-click the Ethernet card that will carry the cross-connect.

Step 5 Verify that the Ethernet card that will carry the circuit is provisioned for Singlecard EtherSwitch. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 6 From the View menu, choose Go to Network View.

Step 7 Click the Circuits tab and click Create.

Step 8 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the cross-connect. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the cross-connect.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the cross-connect size. For single-card EtherSwitch, the available sizes are VC4, VC4-2c and VC4-4c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave the default unchanged (unchecked).

Step 9 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 10 Click Next.

Step 11 Provision the circuit source:

a. From the Node pull-down menu, choose the cross-connect source node.

b. From the Slot pull-down menu, choose the Ethernet card where you verified the single-card EtherSwitch in Step 5.

Step 12 Click Next.

Step 13 Provision the circuit destination:

a. From the Node pull-down menu, choose the cross-connect circuit source node selected in Step 11. (For Ethernet cross-connects, the source and destination nodes are the same.)

b. From the Slot pull-down menu, choose the STM-N card that is connected to the non-ONS equipment.

c. Depending on the STM-N card, choose the port and/or circuit size from the Port and Size pull-down menus.

Step 14 Click Next.

Step 15 Review the VLANs listed under Available VLANs. If the VLAN you want to use is displayed, continue with Step 16. If you need to create a new VLAN, complete the following steps:

a. Click the New VLAN button.

b. On the New VLAN dialog box, complete the following:

VLAN Name—Assign an easily-identifiable name to your VLAN.

VLAN ID—Assign a VLAN ID. The VLAN ID should be the next available number between 2 and 4093 that is not already assigned to an existing VLAN. Each ONS 15454 SDH network supports a maximum of 509 user-provisionable VLANs.

c. Click OK.

Step 16 Click the VLAN you want to use on the Available VLANs column, then click the arrow >> button to move the VLAN to the Circuit VLANs column.

Step 17 Click Next. The Circuit Creation (Circuit Routing Preferences) dialog box opens.

Step 18 Confirm that the following information about the single-card EtherSwitch manual cross-connect is correct (in this task, "circuit" refers to the Ethernet cross-connect):

Circuit name

Circuit type

Circuit size

VLAN names

ONS 15454 SDH nodes

If the information is not correct, click the Back button and repeat the procedure with the correct information.

Step 19 Click Finish.

Step 20 Complete the "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 21 Complete the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task.

Step 22 Complete the "146 Test E-Series Circuits" procedure.

Stop. You have completed this procedure.


NTP-D145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect

Purpose

This procedure manually creates Multicard EtherSwitch cross-connects between E-Series Ethernet cards and STM-N cards connected to non-ONS equipment.

Tools/Equipment

E-Series Ethernet cards must be installed at the circuit source node.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note In this procedure, cross-connect refers to a circuit connection created within the same node between the Ethernet card and an STM-N card connected to third-party equipment. You create cross-connects at the source and destination nodes so an Ethernet circuit can be routed from source to destination across third-party equipment.



Step 1 Log into a circuit endpoint. See "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 Complete the "DLP-D99 Determine Available VLANs" task to verify that sufficient VLAN capacity is available (you will create a VLAN during each circuit creation task).

Step 4 Verify that the Ethernet card that will carry the circuit is provisioned for Multicard EtherSwitch Group. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 5 Provision and enable the Ethernet ports. See "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 6 From the View menu, choose Go to Network View.

Step 7 Click the Circuits tab and click Create.

Step 8 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the source cross-connect. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the source cross-connect.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the size of the circuit that will be carried by the cross-connect. For Multicard EtherSwitch circuits, the available sizes are VC4 and VC4-2c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave Leave the default unchanged (unchecked).

Step 9 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 10 Click Next.

Step 11 Provision the cross-connect source:

a. From the Node pull-down menu, choose the cross-connect source node.

b. From the Slot pull-down menu, choose Ethergroup.

Step 12 Click Next.

Step 13 From the Node pull-down menu under Destination, choose the circuit source node selected in Step 11. (For Ethernet cross-connects, the source and destination nodes are the same.)

The Slot field is provisioned automatically for Ethergroup.

Step 14 Click Next.

Step 15 Review the VLANs listed under Available VLANs. If the VLAN you want to use is displayed, continue with Step 17. If you need to create a new VLAN, complete the following steps:

a. Click the New VLAN button.

b. On the New VLAN dialog box, complete the following:

VLAN Name—Assign an easily-identifiable name to your VLAN.

VLAN ID—Assign a VLAN ID. The VLAN ID should be the next available number between 2 and 4093 that is not already assigned to an existing VLAN. Each ONS 15454 SDH network supports a maximum of 509 user-provisionable VLANs.

c. Click OK.

Step 16 In the Available VLANs column, click the VLAN you want to use and click the arrow button (>>) to move the VLAN to the Circuit VLANs column.

Step 17 Click Next.

The Circuit Creation (Circuit Routing Preferences) dialog box opens.

Step 18 Verify the cross-connect information (in this step, "circuit" refers to the Ethernet cross-connect):

Circuit name

Circuit type

Circuit size

VLANs

ONS 15454 SDH nodes

If the information is not correct, click the Back button and repeat the procedure with the correct information.

Step 19 Click Finish.

Step 20 Complete the "DLP-D220 Provision E-Series Ethernet Ports" task.

Step 21 Complete the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task.

Step 22 From the View menu, choose Go to Home View.

Step 23 Click the Circuits tab.

Step 24 Highlight the circuit and click Edit.

The Edit Circuit dialog box opens.

Step 25 Click Drops and click Create.

The Define New Drop dialog box opens.

Step 26 From the Slot menu, choose the STM-N card that links the ONS 15454 SDH to the non-ONS 15454 SDH equipment.

Step 27 From the Port menu, choose the appropriate port.

Step 28 From theVC4 menu, choose the VC4 that matches the VC4 of the connecting non-ONS 15454 SDH equipment.

Step 29 Click OK.

Step 30 Confirm the circuit information that displays in the Edit Circuit dialog box and click Close.

Step 31 Repeat Steps 3 through 30 at the second Ethernet manual cross-connect endpoint. The first and second created Ethernet circuits will be bridged by the appropriate circuit in the non-ONS equipment.


Note The appropriate circuit must exist in the non-ONS equipment to connect the two Ethernet manual cross-connect endpoints.



Caution If a CARLOSS alarm repeatedly appears and clears on an Ethernet manual cross-connect, the two Ethernet circuits might have a circuit-size mismatch. For example, a circuit size of VC4 was configured on the first ONS 15454 SDH and circuit size of VC4-2c was configured on the second ONS 15454 SDH. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide if the alarm persists .

Step 32 Complete the "146 Test E-Series Circuits" procedure.

Stop. You have completed this procedure.


DLP-D99 Determine Available VLANs

Purpose

This task verifies that the network has the capacity to support the additional new VLANs required for the creation E-Series circuits. It does not apply to E-Series cards in port-mapped mode.

Tools/Equipment

E-Series Ethernet cards must be installed at each end of the Ethernet circuit.

Prerequisite Procedures

127 Verify Network Turn Up

DLP-D60 Log into CTC, page 3-23

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 At any CTC view, click the Circuits tab.

Step 2 Click any existing Ethernet circuit to highlight that row.

Step 3 Click Edit, then click the VLANs tab.

The Edit Circuit dialog displays the number of VLANs used by circuits and the total number of VLANs available for use.

Step 4 Determine that number of available VLANs listed is sufficient for the number of E-series Ethernet circuits that you will create.


Caution Multiple E-series Ethernet circuits with spanning tree enabled will block each other if the circuits traverse the same E-series Ethernet card and use the same VLAN.

Step 5 Return to your originating procedure (NTP).


DLP-D246 Provision E-Series Ethernet Card Mode

Purpose

This task provisions an E-Series Ethernet card for multicard EtherSwitch Group, single-card EtherSwitch or port-mapped mode.

Tools/Equipment

E-Series Ethernet cards must be installed.

Prerequisite Procedures

DLP-D60 Log into CTC, page 3-23

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Caution You cannot change the mode while the Ethernet card is carrying circuits. If you want change the card mode, delete any circuits that it carries first. See the "NTP-D152 Delete Circuits" procedure on page 9-13.


Step 1 In the network view, double-click the node containing the E-Series Ethernet card you want to provision, then double-click the Ethernet card.

Step 2 Click the Provisioning > Ether Card tabs.

Step 3 Under Card Mode, choose one of the following:

For multicard EtherSwitch circuit groups, choose Multicard EtherSwitch Group. Click Apply.

For single-card EtherSwitch circuits, choose Single-card EtherSwitch. Click Apply.

For port-mapped circuits, choose Port-mapped. Click Apply.

Step 4 Multicard EtherSwitch circuits only: repeat Steps 2 and 3 for all other Ethernet cards in the node that will carry the multicard EtherSwitch circuits.

Step 5 Repeat Steps 1 through 4 for other nodes as necesarry.

Step 6 Return to your originating procedure (NTP).


DLP-D220 Provision E-Series Ethernet Ports

Purpose

This task enables ports for the E-Series cards.

Tools/Equipment

None

Prerequisite Procedures

DLP-D60 Log into CTC, page 3-23

Required/As Needed

Required to enable E-Series Ethernet traffic

Onsite/Remote

Onsite or remote

Security

Provisioning or higher



Step 1 Display the node view.

Step 2 Double-click the Ethernet card that you want to provision.

Step 3 Click the Provisioning > Ether Port tabs.

Step 4 For each Ethernet port, provision the following parameters:

Port Name—If you want to label the port, type a port name.

Mode—Choose the appropriate mode for the Ethernet port:

Valid choices for the E100T-G card are Auto, 10 Half, 10 Full, 100 Half, or 100 Full.

Valid choices for the E1000-2-G card are 1000 Full or Auto.


Note Both 1000 Full and Auto mode set the E1000-2-G port to the 1000 Mbps and Full duplex operating mode; however, flow control is disabled when 1000 Full is selected. Choosing Auto mode enables the E1000-2-G card to auto-negotiate flow control. Flow control is a mechanism that prevents network congestion by ensuring that transmitting devices do not overwhelm receiving devices with data. The E1000-2-G port handshakes with the connected network device to determine if that device supports flow control.


Enabled—Click this check box to activate the corresponding Ethernet port.

Priority—Choose a queuing priority for the port. Options range from 0 (Low) to 7 (High). Priority queuing (IEEE 802.1Q) reduces the impact of network congestion by mapping Ethernet traffic to different priority levels. Refer to the priority queuing information in the Cisco ONS 15454 SDH Reference Manual. This parameter does not apply to an E-Series card in port-mapped mode.

Stp Enabled—Click this check box to enable the spanning tree protocol (STP) on the port. This parameter does not apply to an E-Series card in port-mapped mode. Refer to the spanning tree information in the Cisco ONS 15454 SDH Reference Manual.

Step 5 Click Apply.

Step 6 Repeat Steps 1 through 5 for all other cards in the VLAN or in port-mapped mode, repeat Steps 1 through 5 for the other card in a point-to-point circuit.

Step 7 Your Ethernet ports are provisioned and ready to be configured for VLAN membership. See the "DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task for instructions.

Step 8 Return to your originating procedure (NTP).


DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership

Purpose

This task provisions E-Series card ports for VLAN membership. It does not apply to E-Series cards in port-mapped mode.

Tools/Equipment

None

Prerequisite Procedures

DLP-D60 Log into CTC, page 3-23

Required/As Needed

Required to enable Ethernet traffic on E-Series Ethernet cards

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Display the node view.

Step 2 Double-click the E-Series card graphic to open the card.

Step 3 Click the Provisioning > Ether VLAN tabs.

Step 4 To put a port in a VLAN:

a. Click the port and choose either Tagged or Untag. Table 6-5 shows valid port settings.

b. If a port is a member of only one VLAN, choose Untag from the Port column in the VLAN's row. Choose -- for all the other VLAN rows in that Port column.


Note The VLAN with Untag selected can connect to the port, but other VLANs cannot access that port.


c. Choose Tagged at all VLAN rows that need to be trunked. Choose Untag at VLAN rows that do not need to be trunked, for example, the default VLAN.


Note Each Ethernet port must be attached to at least one untagged VLAN. A trunk port connects multiple VLANs to an external device, such as a switch, which also supports trunking. A trunk port must have tagging (802.1Q) enabled for all the VLANs that connect to that external device.


Step 5 After each port is in the appropriate VLAN, click Apply.

.

Table 6-5 VLAN Settings 

Setting
Description

--

A port marked with this symbol does not belong to the VLAN.

Untag

The ONS 15454 SDH will tag ingress frames and strip tags from egress frames.

Tagged

The ONS 15454 SDH will process ingress frames according to the VLAN ID; egress frames will not have their tags removed.



Note If Tagged is chosen, the attached external Ethernet devices must recognize IEEE 802.1Q VLANs.



Note Both ports on an E1000-2-G cards cannot be members of the same VLAN.


Step 6 Return to your originating procedure (NTP).


NTP-D146 Test E-Series Circuits

Purpose

This procedure tests circuits created on E-Series Ethernet cards provisioned for multicard EtherSwitch, single-card EtherSwitch, or port-mapped mode.

Tools/Equipment

Ethernet test set and appropriate fibers

Prerequisite Procedures

This procedure assumes you completed facility loopback tests to test the fibers and cables from the source and destination ONS 15454 SDHs to the fiber distribution panel or the DSX, and one of the following:

191 Create an E-Series EtherSwitch Circuit (Multicard or Single-Card Mode)

142 Create an E-Series Shared Packet Ring Ethernet Circuit

143 Create an E-Series Hub and Spoke Ethernet Configuration

Required/As Needed

As needed

Onsite/Remote

Onsite

Security

Provisioning or higher



Step 1 Log into the ONS 15454 SDH source Ethernet node. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions.

Step 2 On the shelf graphic, double-click the circuit source card.

Step 3 Click the Provisioning > Ether Port tabs.

Step 4 Verify the following settings:

Mode— Auto, 10 Half, 10 Full, 100 Half, or 100 Full.

Enabled—Checked

Priority—Set to the priority level indicated by the circuit or site plan. Priority does not apply to E-Series cards in port-mapped mode.

Stp—Checked if Spanning Tree Protocol is enabled for the circuit. STP does not apply to E-Series cards in port-mapped mode.

Step 5 Click the Ether VLAN tab. If the E-Series cards is not in port-mapped mode, verify that the source port is on the same VLAN as the destination port.

Step 6 Repeat Steps 1 through 5 for the destination node.

Step 7 At the destination node connect the Ethernet test set to the destination port and configure the test set to send and receive the appropriate Ethernet traffic.


Note At this point, you will not be able to send and receive Ethernet traffic.


Step 8 At the source node connect an Ethernet test set to the source port and configure the test set to send and receive the appropriate Ethernet traffic.

Step 9 Transmit Ethernet frames between both test sets. If you cannot transmit and receive Ethernet traffic between the nodes, repeat Steps 1 through 8 to make sure you configured the Ethernet ports and test set correctly.

Step 10 Perform protection switch testing appropriate to the topology:

For SNCP rings, see the "DLP-D94 SNCP Protection Switching Test" task on page 5-36

For MS-SPRings see the "DLP-D91 MS-SPRing Switch Test" task on page 5-24.

Configure your test set according to local site practice. For information about configuring your test set, see your test set user guide.

Step 11 After the Ethernet test is complete, print the results or save them to a disk for future reference. For information about printing or saving test results see your test set user guide.

Stop. You have completed this procedure.


NTP-D147 Create a G-Series Circuit

Purpose

This procedure creates a G-Series circuit.

Tools/Equipment

A G-Series Ethernet card must be installed at each end of the circuit.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 3.

Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit, complete the "DLP-D314 Assign a Name to a Port" task. If you want CTC to assign a name automatically based on circuit type, node name, and sequence number, continue with Step 3.

Step 3 From the View menu, choose Go to Network View.

Step 4 Click the Circuits tab and click Create.

Step 5 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the circuit size. Valid circuit sizes for a G-Series circuit are VC4, VC4-2c, VC4-3c, VC4-4c, VC4-8c, and VC4-16c.


Note Restrictions apply to provisioning multiple circuits on a G-Series card when one of the circuit sizes provisioned is STS-24c. Refer to the Cisco ONS 15454 SDH Reference Manual for complete information.


Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—leave the default unchanged (unchecked).


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Auto-ranged—Unavailable.

Protected Drops—Leave unchecked.

Step 6 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 7 Click Next.

Step 8 Provision the circuit source:

a. From the Node pull-down menu, choose the circuit source node. Either end node can be the point-to-point circuit source.

b. From the Slot pull-down menu, choose the slot containing the G-Series card that you will use for one end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 9 Click Next.

Step 10 Provision the circuit destination:

a. From the Node pull-down menu, choose the circuit destination node.

b. From the Slot pull-down menu, choose the slot containing the G-Series card that you will use for other end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 11 Click Next. The Circuits window appears.

Step 12 Confirm that the following circuit information is correct:

Circuit name

Circuit type

Circuit size

ONS 15454 SDH circuit nodes

Step 13 Click Finish.


Note To change the capacity of a G-Series circuit, you must delete the original circuit and reprovision a new larger circuit.


Step 14 Complete the "149 Test G-Series or ML-Series Circuits" procedure.

Stop. You have completed this procedure.


NTP-D148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode

Purpose

This procedure manually creates a cross-connect between a G-Series Ethernet card or an E-Series in Port-mapped mode and an STM-N card connected to non-ONS equipment.

Tools/Equipment

A G-Series or E-Series card must be installed at the circuit source node.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note In this procedure, cross-connect refers to a circuit connection created within the same node between the Ethernet card and an STM-N card connected to third-party equipment. You create cross-connects at the source and destination nodes so an Ethernet circuit can be routed from source to destination across third-party equipment.



Step 1 Log into a node where you will create the cross-connect. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 If you are provisioning an E-Series card, verify that the Ethernet card that will carry the circuit is provisioned for port-mapped mode. See the "DLP-D246 Provision E-Series Ethernet Card Mode" task.

Step 3 Click the Circuits tab and click Create.

Step 4 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the source cross-connect. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the source cross-connect.

Type—Choose VC_HO_PATH_CIRCUIT.

Size—Choose the size of the circuit that will be carried by the cross-connect. Valid sizes for a G-Series circuit are VC4, VC4-2c, VC4-3c, VC4-4c, VC4-8c, and VC4-16c. For an E-Series in port-mapped mode, valid sizes are VC4, VC4-2c and VC4-4c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

Auto-ranged—Unavailable.

State—Choose a service state to apply to the circuit after it is created:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.

Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Protected Drops—Leave the default unchanged (unchecked).

Step 5 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 6 Click Next.

Step 7 Provision the circuit source:

a. From the Node pull-down menu, choose the circuit source node.

b. From the Slot pull-down menu, choose the Ethernet card that will be the cross-connect source.

c. From the Port pull-down menu, choose the cross-connect source port.

Step 8 Click Next.

Step 9 Provision the circuit destination:

a. From the Node pull-down menu, choose the cross-connect source node selected in Step 9. (For Ethernet cross-connects, the source and destination nodes are the same.)

b. From the Slot pull-down menu, choose the STM-N card that connects to the non-ONS equipment.

c. Depending on the STM-N card, choose the port and VC4 from the Port and VC4 pull-down menus.

Step 10 Click Next.

Step 11 Verify the cross-connect information (in this step, "circuit" refers to the cross-connect):

Circuit name

Circuit type

Circuit size

ONS 15454 SDH circuit nodes

If the information is not correct, click the Back button and repeat the procedure with the correct information.

Step 12 Complete the "149 Test G-Series or ML-Series Circuits" procedure for a G-Series card, or complete the "146 Test E-Series Circuits" procedure for an E-Series card.

Step 13 Click Finish.

Stop. You have completed this procedure.


DLP-D222 Provision G-Series Ethernet Ports

Purpose

This task provisions G-Series Ethernet ports.

Tools/Equipment

None

Prerequisite Procedures

DLP-D60 Log into CTC, page 3-23

Required/As Needed

Required to enable Ethernet traffic on the G-Series

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 In the node view, double-click the G-Series card graphic to open the card.

Step 2 Click the Provisioning > Port tabs.

Step 3 For each G-Series port, provision the following parameters:

Port Name—If you want to label the port, type the port name.

State—Choose IS to put the port in service.

Flow Control Neg—Click this check box to enable flow control negotiation on the port (default). If you do not want to enable flow control, uncheck the box.


Note To activate flow control, the Ethernet device attached to the G-Series card must be set to auto-negotiation. If flow control is enabled but the negotiation status indicates no flow control, check the auto-negotiation settings on the attached Ethernet device.


Max Size—To permit the acceptance of jumbo size Ethernet frames, choose Jumbo (default). If you do not want to permit jumbo size Ethernet frames, choose 1548.


Note The maximum frame size of 1548 bytes enables the port to accept valid Ethernet frames that use protocols, such as ISL. ISL adds 30 bytes of overhead and may cause the frame size to exceed the traditional 1518 byte maximum.


Step 4 Click Apply.

Step 5 Refresh the Ethernet statistics:

a. Click the Performance > Statistics tabs.

b. Click the Refresh button.


Note Reprovisioning an Ethernet port on the G-Series card does not reset the Ethernet statistics for that port.


Step 6 Return to your originating procedure (NTP).


NTP-D149 Test G-Series or ML-Series Circuits

Purpose

This procedure tests circuits created on G-Series Ethernet cards.

Tools/Equipment

Ethernet test set and appropriate fibers

Prerequisite Procedures

This procedure assumes you completed facility loopback tests to test the fibers and cables from the source and destination ONS 15454 SDHs to the fiber distribution panel or the DSX.

147 Create a G-Series Circuit or

148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode

Required/As Needed

As needed

Onsite/Remote

Onsite

Security Level

Provisioning or higher



Step 1 Log into the ONS 15454 SDH source Ethernet node. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions.

Step 2 Change the circuit and circuit ports to an OOS-MT service state:

a. Click the Circuits tab.

b. Click the circuit you want to test.

c. From the Tools menu, choose Circuits > Change Circuit State.

d. On the Change Circuit State dialog box, choose OOS_MT from the Target Circuit State pull-down menu.

e. Check the Apply to circuit drops check box.

f. Click OK.

Step 3 On the shelf graphic, double-click the circuit source card.

Step 4 Click the Provisioning > Port tabs.

Step 5 Verify the following settings:

State—OOS_MT

Flow Control Neg—Checked or unchecked as indicated by the circuit or site plan

Max Size—Check or unchecked as indicated by the circuit or site plan

Media Type— SX, LX, or ZX for G-Series, or SX or LX for ML-Series

Step 6 Repeat Steps 1 through 5 for the destination node.

Step 7 At the destination node connect the Ethernet test to the destination port and configure the test set to send and receive the appropriate Ethernet traffic.


Note At this point, you will not be able to send and receive Ethernet traffic.


Step 8 At the source node connect an Ethernet test set to the source port and configure the test set to send and receive the appropriate Ethernet traffic.

Step 9 Transmit Ethernet frames between both test sets. If you cannot transmit and receive Ethernet traffic between the nodes, repeat Steps 1 through 6 to make sure you configured the Ethernet ports and test set correctly.

Step 10 Perform protection switch testing appropriate to the SDH topology:

For SNCP rings, see the "DLP-D94 SNCP Protection Switching Test" task on page 5-36.

For MS-SPRings see the "DLP-D91 MS-SPRing Switch Test" task on page 5-24.

Configure your test set according to local site practice. For information about configuring your test set, see your test set user guide.

Step 11 Change the circuit and circuit ports to the IS service state:

a. Click the Circuits tab.

b. Choose the circuit you want to test.

c. From the Tools menu, choose Circuits > Change Circuit State.

d. On the Change Circuit State dialog box, choose IS from the Target Circuit State pull-down menu.

e. Check the Apply to circuit drops check box.

f. Click OK.

Step 12 After the circuit test is complete, print the results or save them to a disk for future reference. For information about printing or saving test results see your test set user guide.

Stop. You have completed this procedure.


NTP-D193 Create an ML-Series Circuit

Purpose

This procedure creates an ML-Series point-to-point SDH circuit. Refer to the Cisco ONS 15454 SONET/SDH ML-Series Multilayer Ethernet Card Software Feature and Configuration Guide for more ML-Series information.

Tools/Equipment

An ML-Series Ethernet card must be installed at each end of the circuit.

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 From the View menu, choose Go to Network View.

Step 3 Click the Circuits tab and click Create.

Step 4 In the Create Circuits dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces). Circuit names should be 44 characters or less if you want the ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

Type—Choose VC_HO_PATH_CIRCUIT. For using the VC_LO_PATH_CIRCUIT type option on the ML-Series cards, see "187 Create a Low-Order Aggregation Point" procedure.

Size—Choose the circuit size. Valid circuit sizes for an ML-Series circuit are VC4, VC4-2c, VC4-3c, VC4-4c, and VC4-8c.

Bidirectional—Leave the default unchanged (checked).

Number of Circuits—Leave the default unchanged (1).

State—Choose a service state to apply to the circuit:

IS—The circuit is in service.

OOS—The circuit is out of service. Traffic is not passed on the circuit.

OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the circuit state automatically changes to in service (IS).

OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and allows loopbacks to be performed on the circuit. Use OOS-MT for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or OOS-AINS when testing is complete. See the "DLP-D230 Change a Circuit State" task on page 9-8.

Apply to drop ports—Uncheck this box.


Note Loss of Signal alarms display if in service (IS) ports are not receiving signals.


Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter the service level agreement number. Otherwise, leave the field set to zero.

Auto-ranged—Unavailable.

Protected Drops—Leave the default unchanged (unchecked).

Step 5 If the circuit will be routed on an SNCP ring, complete the "DLP-D218 Provision SNCP Ring Selectors During Circuit Creation" task.

Step 6 Click Next.

Step 7 Provision the circuit source:

a. From the Node pull-down menu, choose the circuit source node. Either end node can be the point-to-point circuit source.

b. From the Slot pull-down menu, choose the slot containing the ML-Series card that you will use for one end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 8 Click Next.

Step 9 Provision the circuit destination:

a. From the Node pull-down menu, choose the circuit destination node.

b. From the Slot pull-down menu, choose the slot containing the ML-Series card that you will use for the other end of the point-to-point circuit.

c. From the Port pull-down menu, choose a port.

Step 10 Click Next. The Circuits window appears.

Step 11 Confirm that the following circuit information is correct:

Circuit name

Circuit type

Circuit size

ONS 15454 SDH circuit nodes

Step 12 Click Finish.

Step 13 Complete the "149 Test G-Series or ML-Series Circuits" procedure.


Note To change the capacity of a ML-Series circuit, you must delete the original circuit and reprovision a new larger circuit.


Stop. You have completed this procedure.


NTP-D194 Create Overhead Circuits

Purpose

This procedure creates overhead circuits on an ONS 15454 SDH network. Overhead circuits include DCC tunnels, the AIC-I card orderwire, and the AIC-I card user data channel.

Tools/Equipment

None

Prerequisite Procedures

127 Verify Network Turn Up

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 Log into a node on the network where you will create the overhead circuit. See the "DLP-D60 Log into CTC" task on page 3-23 for instructions. If you are already logged in, continue with Step 2.

Step 2 From the View menu, choose Go to Network View.

Step 3 As needed, complete the "DLP-D313 Create a DCC Tunnel" task.

Step 4 As needed, complete the "DLP-D83 Provision Orderwire" task.

Step 5 As needed, complete the "DLP-D212 Create a User Data Channel Circuit" task.

Stop. You have completed this procedure.


DLP-D313 Create a DCC Tunnel

Purpose

This task creates a DCC tunnel to transport traffic from third-party SDH equipment across ONS 15454 SDH networks. Tunnels can be created on the Section DCC channel (D1-D3) (if not used by the ONS 15454 SDH as a terminated DCC), or any Line DCC channel (D4-D6, D7-D9, or D10-D12).

Tools/Equipment

None

Prerequisite Procedures

NTP-D35 Verify Node Turn Up, page 5-2

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Note Each ONS 15454 SDH can have up to 32 DCC tunnel connections. Terminated Section DCCs used by the ONS 15454 SDH cannot be used as a DCC tunnel endpoint, and a Section DCC that is used as an DCC tunnel endpoint cannot be terminated. All DCC tunnel connections are bidirectional.



Step 1 In network view, click the Provisioning > Overhead Circuits tabs.

Step 2 Click Create.

Step 3 In the Circuit Creation dialog box (Figure 6-15), provision the DCC tunnel:

Name—Type the tunnel name.

Type—Choose one:

DCC Tunnel-D1-D3—Allows you to choose either the Section DCC (D1-D3) or a Line DCC (D4-D6, D7-D9, or D10-D12) as the source or destination endpoints.

DCC Tunnel-D4-D12—Provisions the full Line DCC as a tunnel.

Source Node—Choose the source node.

Slot—Choose the source slot.

Port—If displayed, select the source port.

Channel—Displayed if you chose DCC Tunnel-D1-D3 as the tunnel type. Choose one of the following:

DCC1 (D1-D3)—is the Section DCC

DCC2 (D4-D6)—is Line DCC 1

DCC3 (D7-D9)—is Line DCC 2

DCC4 (D10-D12)—is Line DCC 3

DCC options are not displayed if they are used by the ONS 15454 SDH (DCC1) or other tunnels.

Figure 6-15 Provisioning a DCC tunnel

Step 4 Click OK.

Step 5 Put the ports that are hosting the DCC tunnel in service. See the "DLP-D214 Change the Service State for a Port" task on page 5-6 for instructions.

Step 6 Return to your originating procedure (NTP).


DLP-D83 Provision Orderwire

Purpose

This task provisions orderwire on the AIC-I card.

Tools/Equipment

An AIC-I card must be installed in Slot 9.

Prerequisite Procedures

NTP-D24 Verify Card Installation, page 4-2

DLP-D60 Log into CTC, page 3-23

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 In the network view, click the Provisioning > Overhead Circuits tabs.

Step 2 Click Create.

Step 3 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces).

Type—Choose either LOW (local orderwire) or EOW (express orderwire) appropriate to the orderwire path that you want to create. If regenerators are not used between ONS 15454 SDH nodes, you can use either local or express orderwire channels. If regenerators exist, use the express orderwire channel. You can provision up to four ONS 15454 SDH STM-N ports for each orderwire path.

PCM—Choose either MU_LAW or A_LAW.

Figure 6-16 shows the Local Orderwire subtab.The provisioning procedures are the same for both types of orderwire.


Caution When provisioning orderwire for ONS 15454 SDHs residing in a ring, do not provision a complete orderwire loop. For example, a four-node ring typically has east and west ports provisioned at all four nodes. However, to prevent orderwire loops, provision two orderwire ports (east and west) at all but one of the ring nodes.

Figure 6-16 Provisioning Local Orderwire

Step 4 Under Endpoints, choose the source and destination nodes and source and destination optical ports and slots from the pull-down menus.

Step 5 Click Finish.

Step 6 Return to your originating procedure (NTP).


DLP-D212 Create a User Data Channel Circuit

Purpose

This task creates a user data channel (UDC) circuit on the ONS 15454 SDH. A UDC circuit allows you to create a dedicated data channel between nodes.

Tools/Equipment

None

Prerequisite Procedures

NTP-D24 Verify Card Installation, page 4-2

DLP-D60 Log into CTC, page 3-23

Required/As Needed

As needed.

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher



Step 1 In network view, click the Provisioning > Overhead Circuits tabs.

Step 2 Click Create.

Step 3 In the Circuit Creation dialog box, complete the following fields:

Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters (including spaces).

Type—Choose either User Data-F1 or User Data D-4-D-12 from the pull-down menu.

Step 4 Under Endpoints, choose the source and destination nodes and source and destination optical ports and slots from the pull-down menus.

Step 5 Click Finish.

Step 6 Return to your originating procedure (NTP).