Installation Overview

RHCS Components and Functionality

Supported RHCS Fencing Options

RHCS HA Local Redundancy Requirements

Configuring Hardware for Prime Central RHCS Local Redundancy HA

Configuring the OS for Prime Central Local Redundancy HA Managed by RHCS

Installing the Red Hat Cluster Service

Verifying the Prime Central RHCS HA Installation

Installing Prime Central and an Embedded Database in a Local Redundancy HA Configuration

Before You Begin

Adding Clustering to the Installed Red Hat Server

Adding Shared Partitions

Accessing and Distributing the Prime Central .tar File

Installing Prime Central on the First Node in an HA Setup

Setting Up the Prime Central Cluster Service

Modifying Parameters in the cluster.conf File

Checking the Cluster Services

Next Steps

Installing Prime Central Fault Management in a Local Redundancy HA Configuration

Before You Begin

Installing RHEL 6.2

Configuring Multipath

Adding Shared Partitions

Setting Up the Prime Central Fault Management Virtual Machine

Distributing the Node .tar File

Distributing the Virtual Machine .tar File

Installing Prime Central Fault Management on the Virtual Machine

GUI-Based Installation

Silent Installation

Setting Up the Fault Management Cluster Service

Checking the Cluster Services

Next Steps

Troubleshooting

Upgrading to Prime Central 1.2 in a Local Redundancy HA Configuration

Upgrading to Prime Central Fault Management 1.2 in a Local Redundancy HA Configuration

Uninstalling Prime Central Fault Management

Uninstalling Prime Central


Quick Start Guide

Cisco Prime Central 1.2 High Availability Quick Start Guide


Revised: August 27, 2013, OL-28573-01

1 Preface

This guide explains how to install Cisco Prime Central and an embedded Oracle database in a local redundancy, high availability (HA) configuration that uses the Red Hat Cluster Suite (RHCS). Other operational redundancy deployments are not supported.

The IP addresses in this guide are shown for illustrative purposes only and are not intended to be actual addresses.

The primary audience for this guide is network operations personnel and system administrators. This guide assumes that you are familiar with the following products and topics:

Basic internetworking terminology and concepts

Network topology and protocols

Red Hat Enterprise Linux administration

Oracle database administration

Telecommunication Management Network (TMN) architecture model

Related Documentation

See the Cisco Prime Central 1.2 Documentation Overview for a list of Prime Central 1.2 guides.


Note We sometimes update the documentation after original publication. Therefore, you should review the documentation on Cisco.com for any updates.


See also the following Red Hat HA and KVM Hypervisor documentation:

Red Hat Enterprise Linux 5 Cluster Administration: Configuring and Managing a Red Hat Cluster

Red Hat Enterprise Linux 5 DM Multipath Configuration and Administration

Red Hat Enterprise Linux 6 Installation Guide

Red Hat Enterprise Linux 6 High Availability Add-On Overview

Red Hat Enterprise Linux 6 Cluster Administration: Configuring and Managing the High Availability Add-On

Red Hat Enterprise Linux 6 Virtualization Administration Guide

Red Hat Enterprise Linux 6 Virtualization Getting Started Guide

Red Hat Enterprise Linux 6 Virtualization Host Configuration and Guest Installation Guide

Red Hat Enterprise Linux 6 Hypervisor Deployment Guide

Red Hat Enterprise Linux 6 DM Multipath Configuration and Administration

Obtaining Documentation and Submitting a Service Request

For information on obtaining documentation, submitting a service request, and gathering additional information, see What's New in Cisco Product Documentation at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html.

Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The RSS feeds are a free service.

2 Installation Overview

The Prime Central RHCS local redundancy HA configuration has the following characteristics and requirements:

Prime Central and the embedded database are installed in a dual-node cluster. Figure 1 shows a basic dual-node, local redundancy cluster.

RHCS must be installed on both cluster nodes. Each node has the platform to run both Prime Central and the database services. RHCS manages the local HA setup.

RHCS requires a disk resource that is mountable from both nodes.

The Prime Central installer places Prime Central and the database on the node where you ran the installation. After installation, you can relocate them as needed.

Prime Central and the database services must placed on the same server.

Prime Central and the embedded database are always mounted with external shared storage.

Prime Central does not recognize RHCS. RHCS continuously obtains the cluster status by running a set of scripts. If a problem occurs, RHCS unmounts, then remounts the appropriate server and database. Therefore, every node in the HA setup must be able to mount the storage.

Note the following:

The Prime Central and oracle home directories must be created manually under the mounted storage. This ensures that the operating system (OS) user created on both servers has a home directory available, even if the storage is moved to another node. These directories must have relevant permissions for the network user and oracle user.

Each service has its own virtual IP address (virtual IP). This means Prime Central clients treat a failover or switchover like a local service restart.

Only one instance of the Prime Central files exists, and it is located on the shared storage. Duplicate user and home directories are created on each node as placeholders. If a switchover occurs, the storage unmounts from one node and mounts on the other.

A local redundancy configuration requires a fencing hardware unit for cutting off a node from the shared storage. Fencing ensures data integrity and prevents a "split-brain scenario" where servers are disconnected from each other, and each assumes the other server failed. If a failure occurs, the cutoff can be performed by:

Powering off the node with a remote power switch

Disabling a switch port fiber channel

Revoking a host's SCSI 3 reservations

If a problem with the cluster node occurs, RHCS invokes the fencing device with the peer and waits for the success signal.

Figure 1 Prime Central Dual-Node, Local Redundancy Cluster

1

External storage

3

Local cluster node 2

2

Local cluster node 1

   

RHCS Components and Functionality

RHCS is included with the Red Hat Enterprise Linux 5.8 (RHEL 5.8) Advanced Program and has the following components:

Cluster infrastructure—Basic functions that enable a group of computers (nodes) to work together as a cluster. The RHCS cluster infrastructure performs cluster management, lock management, fencing, and cluster configuration management.

High availability service management—Failover of services from one cluster node to another when a node becomes inoperative.

Cluster administration tools—Configuration and management tools for setting up, configuring, and managing a Red Hat cluster, including cluster infrastructure components, high availability service management components, and storage.

Supported RHCS Fencing Options

A fencing device cuts off a node from shared storage to ensure data integrity. The supported fencing options are:

fence_ilo—Cisco validated Prime Central HA with the HP Integrated Lights-Out (HP iLO) fence_ilo automatic fencing method; other automatic fencing methods can be used but have not been validated.

fence_manual—Assigns the manual fencing agent. This fencing agent is temporary; you should not use it in production because it does not perform automated actions. If a cluster problem occurs, you must manually disconnect the node and storage, or use another fencing agent to disconnect them. If you choose this option during the installation because you want to add a different Red Hat-supported fencing device, use the RHCS GUI to provision the device after installation. Be sure to add it as the main fencing method, and move the manual fencing agent to the backup method, as shown in Figure 2 and Figure 3.

Note the following:

In Figure 2, the HP iLO host 1 is 192.168.1.10.

In Figure 3, the HP iLO host 2 is 192.168.1.11.

To prevent fencing loops, the cluster interconnect and power fencing (for example, HP iLO) should use the same network, such as bond0.

If the main fencing device is a remote power switch, define all ports that simultaneously supply power to the node.


Note For general information about the RHCS web GUI, see Verifying the Prime Central RHCS HA Installation. For complete information about using the RHCS web GUI, see the Red Hat Conga User Guide. For information about provisioning and managing dual-node cluster fencing devices, see the RHCS user documentation.


Figure 2 RHCS GUI Fencing Method Window—Node 1

1

Backup fencing method

2

Main fencing method


Figure 3 RHCS GUI Fencing Method Window—Node 2

1

Backup fencing method

2

Main fencing method


The fencing methods shown in Figure 2 and Figure 3 change the following sections in the cluster.conf file:

<cluster>
<clusternodes>
<clusternode name="prime-central-linux1.cisco.com" nodeid="1" votes="1">
<multicast addr="224.0.0.251" interface="eth0"/>
<fence>
<method name="method_1">
<device name="hpilofence1"/>
</method>
</fence>
</clusternode>
<clusternode name="prime-central-linux2.cisco.com" nodeid="2" votes="1">
<multicast addr="224.0.0.251" interface="eth0"/>
<fence>
<method name="method_2">
<device name="hpilofence2"/>
</method>
</fence>
</clusternode>
 
   
...
 
   
<fencedevices>
<fencedevice agent="fence_ilo" hostname="value-of-HP-iLO-host-1" login="prime" name="hpilofence1" 
passwd="password"/>
<fencedevice agent="fence_ilo" hostname="value-of-HP-iLO-host-2" login="prime" name="hpilofence2" 
passwd="password"/>
</fencedevices>
 
   
...
 
   
</cluster>

RHCS HA Local Redundancy Requirements

Table 1 Prime Central RHCS HA Local Redundancy Requirements 

Area
Requirement

OS

Red Hat Enterprise Linux 5.8 with the Red Hat Clustering Suite.

Oracle

11gR2 Enterprise Edition.

Note Oracle 11gR2 EE is included in the Prime Central embedded database installation.

Hardware

RHEL 5.8-certified platform with fencing capabilities.

Network

Cluster nodes must be able to communicate with each other using multicast.

Each network switch and the associated networking equipment in a Red Hat cluster must be configured to enable multicast addresses and support IGMP. Without multicast and IGMP, not all nodes can participate in a cluster, causing the cluster to fail.

Network timing must be configured.

Note During the RHCS HA installation, you will be asked to confirm that NTP timing is configured.

Storage and file system

RHCS requires shared Fibre Channel, Fibre Channel over Ethernet (FCoE), or Internet Small Computer System Interface (iSCSI) storage that presents an ext3 file system and is accessible from all cluster nodes.

Disk space

5 GB under /tmp.

Miscellaneous

The same subnet must be assigned to all nodes, including all services (virtual IP addresses in the same subnet).

All nodes must have RHEL 5.8 installed.

All systems must be homogeneous with the same configuration versions and packages.

Shared storage must not be auto-mounted, because RHCS performs the mounting. Use one partition for each cluster service. For a single shared disk, use a single partition for each service on the same disk. In other words, the shared storage must not appear in /etc/fstab.

All shared storage units must be configured with a label, which RHCS uses to mount and unmount storage.

Virtual IP addresses must be assigned for each service. IP addresses assigned to services should not be attached to any server. RHCS will manage them; that is, it will add and remove them from the server that is running the service.

Fencing devices must be deployed.

Multicast communication must not be blocked by a firewall.


We strongly recommend that you use a hardware installation designed to avoid a single point of failure. See Figure 4.

Figure 4 Local Redundancy Hardware Installation Designed to Avoid a Single Point of Failure

1

Dual NICs

4

NIC bonding (active/backup mode)

2

Disk mirroring

5

Each NIC connects to a separate switch

3

Redundant RAID controllers

   

Configuring Hardware for Prime Central RHCS Local Redundancy HA

Figure 5 shows the recommended hardware configuration for Prime Central RHCS local redundancy HA.

Figure 5 Prime Central Dual-Node Cluster for Local Redundancy HA

1

Prime Central external storage: one Prime Central volume

4

Oracle external storage:

One to three data volumes

One archive volume

Zero to three redo log volumes

2

Prime Central server:

Two internal disks

One OS

One mirror

5

Oracle database server:

Two internal disks

One OS

One mirror

3

Dual Gigabit Ethernet crossover connections

6

Dual connections from each server to each external disk storage unit


Configure the external storage so all disks and logical unit numbers (LUNs) are accessible from both servers in the cluster. The disk and LUN configuration depends on the storage type:

If you are using JBOD disks, provide enough physical disks to create the volumes listed in Table 2 to satisfy the Oracle performance requirements.

If you are using storage that supports hardware RAID, divide the physical disks into LUNs so that the volumes listed in Table 2 can be created and configured to satisfy the Oracle performance requirements and can be protected with RAID5, RAID1, or RAID10. The Oracle volumes can be created on a single LUN.

Table 2 Volume Sizes 

Volume
Minimum Size
Comments

Prime Central

50 GB

Oracle application + data files

10 GB

Oracle redo logs

12.8 GB

Oracle archives

20 GB

Contact your Cisco account representative for information.

Oracle additional data files (if used)

Based on Prime Central alarm history.

Oracle backup

50 GB


Configuring the OS for Prime Central Local Redundancy HA Managed by RHCS

To configure the OS for Prime Central local HA managed by RHCS:

1. Install the OS and all recommended patches on both servers in the cluster. Installations on both servers must be identical.

2. Verify that access is available to all external disks.

3. Create the internal disk partitions listed in Table 3. Placing the individual directories in separate partitions is recommended, but not required.

4. Complete the internal disk partitions for both servers.

5. Keep the nodes synchronized:

# echo server tick.redhat.com$'\n'restrict tick.redhat.com mask 255.255.255.255 nomodify notrap noquery >> 
/etc/ntp.conf
# chkconfig ntpd on
# service ntpd start
 
   

Table 3 Disk Partitions

Partition
Space Required (MB)

swap

Standard amount of space, as per the system configuration

/tmp

Standard amount of space + 5120

/

Standard amount of space + 6144

/var

Standard amount of space + 1024 for HA utilities

/usr/local/bin

Standard amount of space + 200 for cluster utilities

/etc

Standard amount of space + 200 for the cluster configuration


Installing the Red Hat Cluster Service

Using the procedures in the Red Hat user documentation, install RHEL 5.8 with the RHCS. When you set up the RHCS disk groups and volumes, keep the following in mind:

All of the shared storage should have an ext3 file system installed and a label set.

Shared storage must be accessible from all cluster nodes.

Verifying the Prime Central RHCS HA Installation

Table 4 Local Redundancy Verification Tests 

Description
Procedure
Expected Results
Local Cluster Hardware Failure

Name: Cluster node hardware failure.

Purpose: Test the local site failover (including fence test) due to node failure.

1. Aggressively power off the active node that runs both services (Prime Central and DB).

2. Verify that both services are relocated to the redundant node.

Within several minutes, the redundant cluster node identifies that the active node is not available and fences it, evicting it from the cluster and relocating all the services to the only remaining node.

Manual Cluster Administration

Name: Manual service stop.

Purpose: Verify that the service can be stopped manually.

1. Enter clusvcadm -d service-name.

2. Verify that the service is not running and no errors appear in the cluster log (/var/log/messages for both cluster nodes).

The stopped service is no longer running.

Name: Manual service start.

Purpose: Verify that the service can be started manually.

1. Enter clusvcadm -e service-name.

2. Verify that the service is running and no errors exist in the cluster log (/var/log/messages on both cluster nodes).

The service is running.

Name: Manual service restart.

Purpose: Verify that the service can be restarted manually.

1. Enter clusvcadm -R service-name.

2. Verify that the service is running and no errors exist in the cluster log (/var/log/messages on both cluster nodes).

The service is running.

Name: Manual service relocation.

Purpose: Verify that the service can be relocated manually.

1. Enter clusvcadm -r service-name.

2. Verify that the service is not running on the current node and is running on the standby node.

3. Verify that no errors appear in the cluster log (/var/log/messages on both cluster nodes). The service is stopped on the active node and then started on the redundant node.

4. Test both the Prime Central and Oracle services.

The service is stopped on the active node and started on the redundant node.

Ordered Cluster Node Startups

Name: Node startup in existing cluster.

Purpose: Verify that a cluster node starts up and rejoins a cluster after it is restarted.

1. Restart one of the cluster nodes.

2. Verify that the node joins the cluster after the reboot.

3. Relocate one of the services to the rebooted node and verify that it is running.

4. Check the log for errors.

The rebooted node joins the cluster and runs the services.

Name: Simultaneous node startup.

Purpose: Verify that the cluster is set up correctly when both nodes start simultaneously.

1. Start both nodes from the power off state.

2. Verify that both nodes appear in the cluster after they are up, with both services running on the cluster.

3. Check the log for errors.

Both cluster nodes join the cluster; both services are running.

Name: Single-node startup.

Purpose: Test the cluster functionality when only one is node running.

1. Power down both nodes, then start one of them.

The running node fences the other node and runs the services. The fenced node joins the cluster to create the dual-node cluster.

2. Check the log for errors.

Both cluster nodes join the cluster; both services are running.

Local Cluster Service Failure

Name: Service failure.

Purpose: Test the service startup after a failure occurs.

1. Simulate a service failure by stopping its processes or shutting down the Oracle listener.

2. Verify that the service restarts on the same node where it was running.

3. Check the log for errors.

4. Test both the Prime Central and Oracle services.

The service is restarted on the same node.

Local Cluster Hardware Failure

Name: Stop node with fencing off.

Purpose: Verify that the node requires manual fencing after the other node, including its fencing agent, is removed.

1. Disconnect the fencing agent from one of the nodes, then power it off.

2. Observe the other node behavior.

3. Check the log for errors and the request for manual fencing.

The fence_ack_manual required notification appears in the log files. The cluster is running with one node and all services running on it.

Name: Single-node cluster.

Purpose: Verify that the cluster can function when the other node does not exist or has no power.

1. Power down both nodes.

2. Disconnect the fencing agent from one of the nodes.

3. Start the other node. It attempts to fence the other node, but fails with the regular fencing agent. Manual fencing is required.

4. Acknowledge the manual fencing.

The cluster does not start the services (and does not show in the clustat command) before acknowledging that manual fencing is performed.


3 Installing Prime Central and an Embedded Database in a Local Redundancy HA Configuration

Installing Prime Central in an RHCS local HA configuration is a three-part process:

1. Install RHEL 5.8 on both nodes.

2. Use multipath shared storage and install Prime Central on node 1.

3. Configure and enable clustering so that Prime Central can relocate between nodes.

The examples provided use the following hostnames and IP addresses; yours will be different:

Node 1—prime-ha-node1.cisco.com (192.168.1.110)

Node 2—prime-ha-node2.cisco.com (192.168.1.120)

Virtual IP address—prime-service.cisco.com (192.168.1.130)

Gateway—192.168.1.1

Domain Name System (DNS)—192.168.1.2

Figure 6 shows an example of a Prime Central cluster in an HA configuration.

Figure 6 Prime Central Cluster in an HA Configuration

Before You Begin

Verify that your system meets all the hardware and software requirements in "Installation Requirements" in the Cisco Prime Central 1.2 Quick Start Guide.

Set up two nodes that have:

Static IP addresses and hostnames that are registered correctly in the DNS.

The same root password, which cannot contain a percent sign (%).

Set up one virtual IP address and hostname that are registered correctly in the DNS. In this section, the virtual IP address is 192.168.1.130.

Set up shared storage that is compatible with RHEL device-mapper (DM) multipath and cluster fencing.

Install RHEL 5.8 on both nodes.

If you changed the default installation folder (/opt/pc/primecentral), make the equivalent changes in the following files (look for the section titled "Require manual definition" in each file):

/root/ha-stuff/pc/PrimeCentral.sh

/root/ha-stuff/pc/UninstallPrimeCentral.sh

/usr/local/bin/pc.sh

Adding Clustering to the Installed Red Hat Server

To add clustering to the newly installed Red Hat server, complete the following steps in parallel on both nodes, except where noted:


Step 1 Create local directories named /rhel and /cdrom.

Step 2 Copy the .iso file that was used for the virtual machine (VM) RHCS installation to the /rhel directory.

Step 3 Mount the /rhel .iso file to /cdrom:

# cd /rhel
# mount -t iso9660 -o loop /rhel/rhel-server-5.8-x86_64-dvd.iso /cdrom
 
   

Note To permanently mount the drive, update the /etc/fstab file. See http://docs.redhat.com/docs/en-US/Red_Hat_Enterprise_Linux/4/html/Introduction_To_System_Administration/s2-storage-mount-fstab.html.


Step 4 Create a file named /etc/yum.repos.d/local.repo. Use UNIX format and be sure there are no spaces before lines.

Step 5 Save the newly created file in local.repo, as follows:

[local]
name=Red Hat Enterprise Linux $releasever - $basearch - Local
baseurl=file:///cdrom/Server
enabled=1
gpgcheck=0
gpgkey=file:///etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release
 
   
[cluster]
name=Red Hat Enterprise Linux $releasever - $basearch - Cluster
baseurl=file:///cdrom/Cluster
enabled=1
gpgcheck=0
gpgkey=file:///etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release
 
   

Step 6 Install the clustering package:

# yum groupinstall Clustering
 
   

Step 7 Add the information for both nodes to the /etc/hosts file; for example:

192.168.1.110     prime-ha-node1.cisco.com     prime-ha-node1
192.168.1.120     prime-ha-node2.cisco.com     prime-ha-node2
 
   

Step 8 Generate a Secure Shell (SSH) key for the root user:

# chmod 755 ~
# ssh-keygen -t rsa -N "" -b 2047 -f ~/.ssh/id_rsa
# chmod 600 ~/.ssh/id_rsa
 
   

Step 9 (On the first node only) Share the node's public key with the other node so that dynamically creating a secure shell between the nodes does not prompt for a password:

# rsync -av ~/.ssh/id_rsa.pub ~/.ssh/authorized_keys
# ssh root@node2 "cat ~/.ssh/id_rsa.pub" >> ~/.ssh/authorized_keys
# rsync -av ~/.ssh/authorized_keys root@prime-ha-node2.cisco.com:/root/.ssh/
 
   

Step 10 Verify that the .ssh directory has 700 permission and the .ssh/id_rsa file has 600 permission:

# chmod 700 ~/.ssh
# chmod 600 ~/.ssh/id_rsa
 
   

Step 11 Verify that your SSH is working without an authentication or password prompt:


Caution The Prime Central service will not start if SSH prompts for authentication or a password. Be sure to complete all of the following substeps.

a. On node prime-ha-node1.cisco.com, enter:

# ssh root@prime-ha-node2.cisco.com
# exit
# ssh root@prime-ha-node2
# exit
# ssh root@192.168.1.120
# exit

b. On node prime-ha-node2.cisco.com, enter:

# ssh root@prime-ha-node1.cisco.com
# exit
# ssh root@prime-ha-node1
# exit
# ssh root@192.168.1.110
# exit

c. If you are prompted for a password, check the permissions of all folders and files that you modified in the preceding steps.

d. If you are prompted to continue connecting, enter yes. (The prompt should appear only the first time you use SSH to connect to the node.)

Step 12 Verify that the virtual IP address is accessible from outside the cluster's subnet:

# ip addr add 192.168.1.130 dev eth0
 
   

Step 13 On a computer outside the cluster's subnet, ping the virtual IP address:

# ping 192.168.1.130
# ip addr del 192.168.1.130 dev eth0
 
   

If you do not get a valid response, determine which part of the OS or network setup is blocking.


Adding Shared Partitions

To add shared partitions, complete the following steps in parallel on both nodes, except where noted:


Note The examples provided use device mapping names such as mpath2 and mpath2p1; yours will be different.



Step 1 Set up multipath:

# vi /etc/multipath.conf
-- Comment out 'blacklist' section
-- For example:
-- #blacklist {
# devnode "*"
#}
# modprobe dm-multipath
# service multipathd start
# chkconfig multipathd on
 
   

Step 2 Check for available disks:

cd /dev/mapper/
ls -la
total 0
drwxr-xr-x  2 root root     120 May  4 18:42 .
drwxr-xr-x 13 root root    3940 May  4 18:42 ..
crw-------  1 root root  10, 63 May  4 18:42 control
brw-rw----  1 root disk 253,  2 May  4 18:42 mpath2
brw-rw----  1 root disk 253,  0 May  4 18:42 VolGroup00-LogVol00
brw-rw----  1 root disk 253,  1 May  4 18:42 VolGroup00-LogVol01
 
   

In the output, note mpath2, which is the multipath virtual device or disk that you will use later as shared storage.


Note If you previously set up a partition on the disk, you might see output such as mpath2p. You must delete that partition before proceeding to the next step.


Step 3 (On the first node only) Create a 100-GB, shared partition:

# fdisk mpath2
Command (m for help): p
Command (m for help): n
Command action
   e   extended
   p   primary partition (1-4)
p
Partition number (1-4): 1
First cylinder (1-19581, default 1): 
Using default value 1
Last cylinder or +size or +sizeM or +sizeK (1-19581, default 19581): +100GB
Command (m for help): w
 
   

Step 4 Reboot both nodes.

Step 5 Check for new partitions:

# cd /dev/mapper/
# ls -la
total 0
drwxr-xr-x  2 root root     180 May  4 19:49 .
drwxr-xr-x 13 root root    4120 May  4 19:49 ..
crw-------  1 root root  10, 63 May  4 19:49 control
brw-rw----  1 root disk 253,  2 May  4 19:49 mpath2
brw-rw----  1 root disk 253,  3 May  4 19:49 mpath2p1
brw-rw----  1 root disk 253,  0 May  4 19:49 VolGroup00-LogVol00
brw-rw----  1 root disk 253,  1 May  4 19:49 VolGroup00-LogVol01
 
   

Step 6 (On the first node only) Format the new shared partition:

# mkfs.ext3 /dev/mapper/mpath2p1
 
   

Step 7 Create target locations:

# mkdir /opt/pc
 
   

Step 8 Verify that both nodes can mount and unmount the shared storage:

a. On the first node, mount the shared storage and save a file that contains only the value 1 to the shared storage. The test.txt file should exist in the list of contents of /opt/pc:

# mount /dev/mapper/mpath2p1 /opt/pc
# vi /opt/pc/test.txt
1
:wq
# ls -la /opt/pc
# umount /opt/pc

b. On the second node, mount the shared storage and verify that the test.txt file exists and contains the value 1:

# mount /dev/mapper/mpath2p1 /opt/pc
# vi /opt/pc/test.txt
:q
# umount /opt/pc

If you cannot mount or unmount the shared storage, or if the test.txt file does not exist when you mount it to the second node, your multipath is not set up correctly.


Accessing and Distributing the Prime Central .tar File


Step 1 Insert the Cisco Prime Central 1.2 USB, navigate to the High Availability/Prime Central folder, and locate the primecentral_v1.2_ha_vm.tar.gz file.

Step 2 Use SSH to connect to the first node.

Step 3 Copy the primecentral_v1.2_ha_vm.tar.gz file to the first node.

Step 4 Back up the following directories on both nodes:

/root/ha-stuff/pc

/usr/local/bin

Step 5 Distribute the file:

# tar -zxf primecentral_v1.2_ha_vm.tar.gz -C / --owner root --no-same-owner
# chmod 755 /root/ha-stuff/pc/*
# chmod 755 /usr/local/bin/*
 
   

Installing Prime Central on the First Node in an HA Setup

To install Prime Central on the first node only:


Step 1 Mount the shared partitions:

# mount /dev/mapper/mpath2p1 /opt/pc
 
   

Step 2 Add a virtual IP cluster service address for the Prime Central service:

# ip addr add 192.168.1.130 dev eth0
 
   

Step 3 Update the install.properties file and verify that all required properties have values. Review the comments at the top of the install.properties file for details.


Note To install Prime Central silently, you must edit the /root/ha-stuff/pc/install.properties file. See "Sample install.properties Files" in the Cisco Prime Central 1.2 Quick Start Guide.


Step 4 Install Prime Central:

# cd /root/ha-stuff/pc
# ./PrimeCentral.sh 192.168.1.130 node's-root-password second-node-IP-address
 
   

Note You run the PrimeCentral.sh script by adding the preceding command-line parameters. If you do not add the command-line parameters, you are prompted for the required data.


Step 5 In another terminal window, check the installation process:

# tail -f /tmp/primecentral_install.log
 
   

Step 6 After the installation succeeds, start Prime Central:

# /usr/local/bin/pc.sh start
 
   

Step 7 Verify that Prime Central is running correctly; then, stop it:

# /usr/local/bin/pc.sh stop
 
   

Step 8 Remove the virtual IP addresses:

# ip addr del 192.168.1.130 dev eth0
 
   

Step 9 Unmount the shared partitions:

# umount /opt/pc
 
   

Setting Up the Prime Central Cluster Service

To set up and manage a cluster, you can use the CLI or the GUI. This section explains how to use the CLI. To use the GUI, see the Red Hat Enterprise Linux 5 Cluster Administration Guide, sections 3 and 4.

To set up the Prime Central cluster service, complete the following steps in parallel on both nodes, except where noted:


Step 1 Modify the /etc/cluster/cluster.conf file by setting unique values for the parameters listed in Table 5.

Step 2 Copy the edited cluster.conf file to the /etc/cluster/ directory.

Whenever you modify the cluster.conf file, increment the config_version value so the cluster.conf file propagates correctly to the nodes. To propagate the cluster.conf file manually, you must stop the cluster, copy the file, and then start the cluster.

Step 3 Start the cluster services:

# service cman start
# service rgmanager start
 
   

Enter each command on one node and then immediately enter the same command on the other node.

For example, when cman starts on a node, it waits for the other node to start cman. If the other node takes too long to start cman, cman times out on the first node.

Step 4 (For the RHCS luci GUI only) Using the username admin, start the RHCS ricci service:

# service ricci start
 
   

Step 5 (For the RHCS luci GUI only) On the first node only, start the RHCS luci services:

# luci_admin init
# service luci start
 
   

Step 6 To test failover, relocate the service to another node:

# clusvcadm -r vmpcservice -m prime-ha-node2.cisco.com
 
   

Step 7 After the Prime Central service is running in an HA cluster, you cannot restart its components (such as the portal, integration layer, and database) without first freezing the cluster. After you restart the component, you can unfreeze the cluster.

For example, attaching or detaching an application to or from Prime Central requires an integration layer restart. On the active node, freeze the HA cluster, restart the integration layer, and unfreeze the cluster:

# clusvcadm -Z Prime-Central-service-name
# su - primeusr
# itgctl stop
# itgctl start
# exit
# clusvcadm -U Prime-Central-service-name
 
   

Modifying Parameters in the cluster.conf File

The following table lists the parameters in the /etc/cluster/cluster.conf file for which you must set unique values.

Table 5 Parameters to Modify in the cluster.conf File 

Parameter
Default Value
Notes

Cluster name

bm1cluster

Multicast address

224.0.0.251

The multicast address must be unique per subnet and must be working before you start your cluster. For a tool to verify that your multicast address is correct, see Troubleshooting.

Service IP address

192.168.1.130

First node name

prime-ha-node1.cisco.com

Second node name

prime-ha-node2.cisco.com

Shared partition path

/dev/mapper/mpath2p1


Checking the Cluster Services

On both nodes, check the status of the cluster:

# clustat
 
   

The output is similar to the following:

Cluster Status for bm1cluster @ Thu Jun 27 23:58:35 2013
Member Status: Quorate
 
   
Member Name                  ID    Status
------ ----                  ----  ------
prime-ha-node1.cisco.com     1     Online, Local, rgmanager
prime-ha-node2.cisco.com     2     Online, rgmanager
 
   
Service Name                  Owner (Last)                  State         
------- ----                  ----- ------                  -----         
service:vmpcservice           prime-ha-node2.cisco.com      started

Next Steps

Complete the following steps on both nodes, except where noted:


Step 1 Configure cman, rgmanager, and ricci to start automatically upon bootup:

# chkconfig cman on
# chkconfig rgmanager on
# chkconfig ricci on
 
   

Step 2 (On the first node only) Configure luci to start automatically upon bootup:

# chkconfig luci on
 
   

Step 3 Verify that the required ports are open. For a list of ports that Prime Central requires, see "Prime Central Protocols and Ports" in the Cisco Prime Central 1.2 Quick Start Guide.

Step 4 Enable the firewall:

# service iptables start
# chkconfig iptables on
# service ip6tables start
# chkconfig ip6tables on
 
   

Step 5 Disable Security-Enhanced Linux (SELinux):

# vi /etc/selinux/config
SELINUX=disabled
 
   

4 Installing Prime Central Fault Management in a Local Redundancy HA Configuration

Installing the Prime Central Fault Management component in a dual-node, RHCS HA configuration is a three-part process:

1. Install Red Hat Enterprise Linux 6.2 (RHEL 6.2) with HA and kernel-based virtual machine (KVM) packages on each node.

2. Create a single virtual machine installed with RHEL 5.8 and running the Prime Central Fault Management component.

3. Use multipath shared storage that contains the virtual machine image.

The examples provided use the following hostnames and IP addresses; yours will be different:

Node 1—fm-ha-node1.cisco.com (192.168.1.150)

Node 2—fm-ha-node2.cisco.com (192.168.1.160)

Virtual IP address—fm-service.cisco.com (192.168.1.170)

Gateway—192.168.1.1

DNS—192.168.1.2

Figure 7 shows an example of a Fault Management cluster in an HA configuration.

Figure 7 Fault Management Cluster in an HA Configuration

Before You Begin

Verify that your system meets all the hardware and software requirements in "Installation Requirements" in the Cisco Prime Central 1.2 Quick Start Guide.

If you changed the default installation folder (/opt/primeusr/faultmgmt), make the equivalent changes in the following files (look for the section titled "Require manual definition" in each file):

/usr/local/bin/fm.sh

/images/fm_status.sh

Installing RHEL 6.2

To install RHEL 6.2, complete the following steps in parallel on both nodes, except where noted:


Step 1 Configure specialized storage devices, high availability, and virtualization. See the Red Hat documentation for instructions.

Step 2 Verify that the following options are checked:

Virtualization: Virtualization Tools

High Availability: High Availability

Desktops: General Purpose Desktop

Desktops: X Window System

Step 3 Create local directories named /rhel and /cdrom-6.2.

Step 4 Copy the .iso file that was used for the node installation to the /rhel directory.

Step 5 Mount the /rhel .iso file to /cdrom-6.2:

# cd /rhel
# mount -t iso9660 -o loop /rhel/rhel-server-6.2-x86_64-dvd.iso /cdrom-6.2
 
   

Note To permanently mount the drive, update the /etc/fstab file. See http://docs.redhat.com/docs/en-US/Red_Hat_Enterprise_Linux/4/html/Introduction_To_System_Administration/s2-storage-mount-fstab.html.


Step 6 Create a file named /etc/yum.repos.d/local.repo. Use UNIX format and be sure there are no spaces before lines.

Step 7 Save the newly created file in local.repo, as follows:

[local]
name=Red Hat Enterprise Linux $releasever - $basearch - Local
baseurl=file:///cdrom-6.2/Server
enabled=1
gpgcheck=0
gpgkey=file:///etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release
 
   
[HighAvailability]
name=Red Hat Enterprise Linux $releasever - $basearch - HighAvailability
baseurl=file:///cdrom-6.2/HighAvailability
enabled=1
gpgcheck=0
gpgkey=file:///etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release
 
   
[ResilientStorage]
name=Red Hat Enterprise Linux $releasever - $basearch - ResilientStorage
baseurl=file:///cdrom-6.2/ResilientStorage
enabled=1
gpgcheck=0
gpgkey=file:///etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release
 
   

Step 8 (Optional) If you forget the HA package and want to install it later, enter:

# yum groupinstall "High Availability"
 
   

Step 9 (Optional) If you forget the desktop and want to install it later, enter:

# yum groupinstall "X Window System" Desktop
# vi /etc/inittab
 
   

Then, change id:3:initdefault: to id:5:initdefault: and reboot the server.

Step 10 Temporarily disable the firewall and SELinux to enable initial testing of the cluster:

a. To disable the firewall, enter:

# service iptables save
# service iptables stop
# chkconfig iptables off
# service ip6tables save
# service ip6tables stop
# chkconfig ip6tables off

b. To disable SELinux, enter:

# vi /etc/selinux/config
change
SELINUX=enforcing
to
SELINUX=disabled

Step 11 Keep the nodes synchronized:

# echo server tick.redhat.com$'\n'restrict tick.redhat.com mask 255.255.255.255 nomodify notrap noquery 
>> /etc/ntp.conf
# chkconfig ntpd on
# service ntpd start
 
   

Step 12 Switch network daemons:

# service NetworkManager stop
# chkconfig NetworkManager off
# yum remove NetworkManager
# chkconfig network on
 
   

Step 13 Edit the /etc/hosts file to add the node information; for example:

192.168.1.150 prime-ha-node1.cisco.com prime-ha-node1
192.168.1.160 prime-ha-node2.cisco.com prime-ha-node2
 
   

Step 14 Generate an SSH key for the root user:

# chmod 755 ~
# ssh-keygen -t rsa -N "" -b 2047 -f ~/.ssh/id_rsa
# chmod 600 ~/.ssh/id_rsa
 
   

Step 15 (On the first node only) Share the node's public key with the other node so that dynamically creating a secure shell between the nodes does not prompt for a password:

# rsync -av ~/.ssh/id_rsa.pub ~/.ssh/authorized_keys
# ssh root@node2 "cat ~/.ssh/id_rsa.pub" >> ~/.ssh/authorized_keys
# rsync -av ~/.ssh/authorized_keys root@node2:/root/.ssh/
 
   

Step 16 Verify that the .ssh directory has 700 permission and the .ssh/id_rsa file has 600 permission:

# chmod 700 ~/.ssh
# chmod 600 ~/.ssh/id_rsa
 
   

Step 17 Verify that your SSH is working without an authentication or password prompt:


Caution The Fault Management service will not start if SSH prompts for authentication or a password. Be sure to complete all of the following substeps.

a. On node prime-ha-node1.cisco.com, enter:

# ssh root@prime-ha-node2.cisco.com
# exit
# ssh root@prime-ha-node2
# exit
# ssh root@192.168.1.150
# exit

b. On node prime-ha-node2.cisco.com, enter:

# ssh root@prime-ha-node1.cisco.com
# exit
# ssh root@prime-ha-node1
# exit
# ssh root@192.168.1.160
# exit

c. If you are prompted for a password, check the permissions of all folders and files that you modified in the preceding steps.

d. If you are prompted to continue connecting, enter yes. (The prompt should appear only the first time you use SSH to connect to the node.)


Configuring Multipath

To configure multipath, complete the following steps in parallel on both nodes, except where noted:


Note These steps set up a nonclustered drive. If you want to do a live migration of your virtual machines, you must set up a clustered drive such as the Clustered Logical Volume Manager (CLVM).



Step 1 Install multipath:

# yum install device-mapper-multipath
 
   

Step 2 Configure and start the services:

# mpathconf --enable --user_friendly_names y --find_multipaths y
# modprobe dm_multipath
# service multipathd start
# chkconfig multipathd on
 
   

Step 3 Check for available disks. The names of the multipath disks must be identical on both nodes:

cd /dev/mapper/
ls -la
total 0
drwxr-xr-x.  2 root root    160 Jul 12 19:28 .
drwxr-xr-x. 18 root root   4160 Jul 12 19:28 ..
crw-rw----.  1 root root 10, 58 Jul 12 19:09 control
lrwxrwxrwx.  1 root root      7 Jul 12 19:28 mpathc -> ../dm-3
lrwxrwxrwx.  1 root root      7 Jul 12 19:09 vg_primehanode2-lv_home -> ../dm-2
lrwxrwxrwx.  1 root root      7 Jul 12 19:09 vg_primehanode2-lv_root -> ../dm-0
lrwxrwxrwx.  1 root root      7 Jul 12 19:09 vg_primehanode2-lv_swap -> ../dm-1
 
   

In the output, note mpathc, which is the multipath virtual device or disk that you will use later as shared storage.


Adding Shared Partitions

To add shared partitions, complete the following steps in parallel on both nodes, except where noted:


Note The examples provided use device mapping names such as mpathc and mpathcp1; yours will be different.



Step 1 (On the first node only) Create a 100-GB, shared partition:

# cd /dev/mapper
# fdisk mpathc
Command (m for help): p
Command (m for help): n
Command action
   e   extended
   p   primary partition (1-4)
p
Partition number (1-4): 1
First cylinder (1-19581, default 1): 
Using default value 1
Last cylinder or +size or +sizeM or +sizeK (1-19581, default 19581): +100GB
Command (m for help): w
 
   

Step 2 Reboot both nodes.

Step 3 Check for new partitions:

# cd /dev/mapper/
# ls -la
total 0
drwxr-xr-x  2 root root     180 May  4 19:49 .
drwxr-xr-x 13 root root    4120 May  4 19:49 ..
crw-------  1 root root  10, 63 May  4 19:49 control
brw-rw----  1 root disk 253,  2 May  4 19:49 mpathc
brw-rw----  1 root disk 253,  3 May  4 19:49 mpathcp1
brw-rw----  1 root disk 253,  0 May  4 19:49 VolGroup00-LogVol00
brw-rw----  1 root disk 253,  1 May  4 19:49 VolGroup00-LogVol01
 
   

Step 4 Create target locations on both nodes:

# mkdir /images
 
   

Step 5 Check if the new partition is mapped to another server:

# mount /dev/mapper/mpathcp1 /images
 
   

If the mount fails due to an invalid file type, the partition is not a link to an existing partition; skip to Step 6.

Otherwise, run a directory listing of /images. If the listing contains data from an existing partition, do not reformat this partition. Instead, leave this partition as is and return to Step 1 to create another partition.

Step 6 (On the first node only) Format the new shared partition:

# mkfs.ext4 /dev/mapper/mpathcp1
 
   

Step 7 Verify that both nodes can mount and unmount the shared storage:

a. On the first node, mount the shared storage and save a file that contains only the value 1 to the shared storage. The test.txt file should exist in the list of contents of /images:

# mount /dev/mapper/mpathcp1 /images
# vi /images/test.txt
1
:wq
# ls -la /images
# umount /images

b. On the second node, mount the shared storage and verify that the test.txt file exists and contains the value 1:

# mount /dev/mapper/mpathcp1 /images
# vi /images/test.txt
:q
# umount /images

If you cannot mount or unmount the shared storage, or if the test.txt file does not exist when you mount it to the second node, your multipath is not set up correctly.


Setting Up the Prime Central Fault Management Virtual Machine


Step 1 Mount the newly created partition on the first node:

# mount /dev/mapper/mpathcp1 /images
 
   

Step 2 (On the first node only) Add a new storage pool:

a. Run vncserver and use the VNC client to access the node.

b. Launch the virt-manager.

c. Click Edit Connection Details.

d. Click the Storage tab.

e. Click the + button to add a new storage pool.

f. In the Add a New Storage Pool: Step 1 of 2 window, enter fm_images as the storage pool name, choose fs: Pre-Formatted Block Device as the type, and click Forward.

g. In the Add a New Storage Pool: Step 2 of 2 window, verify that the settings are as follows; then, click Finish:

Target Path: /images

Format: auto

Source Path: /dev/mapper/mpathcp1

Step 3 (On the first node only) Add a new storage volume:

a. In the virt-manager, click the Storage tab.


Caution Do not check the Autostart: On Boot check box.

b. Click the New Volume button.

c. In the Add a Storage Volume window, enter the following values; then, click Finish:

Name: fm_vm (.img is appended)

Format: raw

Max Capacity (MB): Use all available storage space from the pool.

Allocation (MB): 0

Step 4 Create a virtual network:

a. On each node, add a bridge to the host, to enable the virtual machines to use the same physical network as the nodes:

# cd /etc/sysconfig/network-scripts/
# vi ifcfg-br0

Add these lines and save:

DEVICE=br0
TYPE=Bridge
BOOTPROTO=static
ONBOOT=yes
DELAY=0
IPADDR=192.168.1.150
GATEWAY=192.168.1.1
DNS1=192.168.1.2

Note The IPADDR has the same value as the node to which you are adding this file. This example is for node 1.


# vi ifcfg-eth0

Add this line and save:

BRIDGE=br0
# service network restart
# brctl show
bridge name bridge id STP enabled interfaces
br0 8000.0025b500005b no eth0
vnet0
virbr0 8000.5254003af3e9 yes virbr0-nic

b. On each node, update the /etc/sysctl.conf file to allow forwarding to the virtual machines:

# vi /etc/sysctl.conf
net.ipv4.ip_forward = 1

Step 5 Create a new virtual machine:

a. Copy the RHEL 5.8 .iso file to the /rhel directory.

b. In the virt-manager window, click the create a new virtual machine button.

c. In the Step 1 of 5 window, enter fm_vm as the virtual machine name, click Local install media, and click Forward.

d. In the Step 2 of 5 window, click Use ISO image and specify the location of the RHEL 5.8 .iso image. Verify that the OS type is Linux and the version is Red Hat Enterprise Linux 5.4 or later. Then, click Forward.

e. In the Step 3 of 5 window, enter the amount of RAM and CPUs to use for the virtual machine. For recommendations, see "Installation Requirements" in the Cisco Prime Central 1.2 Quick Start Guide. Then, click Forward.

f. In the Step 4 of 5 window, check Enable storage for this virtual machine. Click Select managed or other existing storage and browse to /images/fm_vm.img (which you created in Step 3c). Then, click Forward.

g. In the Step 5 of 5 window, verify that the settings are as follows; then, click Finish:

Advanced options: Host device eth0 (Bridge 'br0')

Virt Type: kvm

Architecture: x86_64

Step 6 Install RHEL 5.8 on the new virtual machine. The OS library, kernel-headers, is required; choose the Software Development option when installing RHEL to ensure that the kernel-headers library is installed.

Step 7 Temporarily disable the firewall and SELinux to enable initial testing of the cluster:

a. To disable the firewall, enter:

# service iptables save
# service iptables stop
# chkconfig iptables off
# service ip6tables save
# service ip6tables stop
# chkconfig ip6tables off

b. To disable SELinux, enter:

# vi /etc/selinux/config
change
SELINUX=enforcing
to
SELINUX=disabled

Step 8 Update the /etc/hosts file on the virtual machine:

# IP-address FQDN hostname
 
   

For example:

192.168.1.170 fm-service.cisco.com fm-service
 
   

Step 9 From the virtual machine, ping both nodes. If the ping fails, add both nodes to the virtual machine's /etc/hosts file. For example:

192.168.1.150 prime-ha-node1.cisco.com prime-ha-node1
192.168.1.160 prime-ha-node2.cisco.com prime-ha-node2
 
   

Step 10 Save the /etc/hosts file; then, run the following tests:

# hostname -a
fm-service
# hostname -f
fm-service.cisco.com
# hostname -i
192.168.1.170
# ipcalc -h 192.168.1.170
HOSTNAME=fm-service.cisco.com
 
   

If any of the tests return incorrect results, check the /etc/hosts file for typos. Also check the /etc/sysconfig/network file and verify that the HOSTNAME entry contains your server's FQDN (fm-service.cisco.com in this example).

Step 11 Generate an SSH key for the virtual machine's root user and share it with both nodes:

# chmod 755 ~
# ssh-keygen -t rsa -N "" -b 2047 -f ~/.ssh/id_rsa
# chmod 600 ~/.ssh/id_rsa
 
   
# rsync -av ~/.ssh/id_rsa.pub ~/.ssh/authorized_keys
# ssh root@prime-ha-node1.cisco.com "cat ~/.ssh/id_rsa.pub" >> ~/.ssh/authorized_keys
# ssh root@prime-ha-node2.cisco.com "cat ~/.ssh/id_rsa.pub" >> ~/.ssh/authorized_keys
# rsync -av ~/.ssh/authorized_keys root@prime-ha-node1.cisco.com:/root/.ssh/
# rsync -av ~/.ssh/authorized_keys root@prime-ha-node2.cisco.com:/root/.ssh/
 
   

Step 12 On the virtual machine, verify that the .ssh directory has 700 permission and the .ssh/id_rsa file has 600 permission:

# chmod 700 ~/.ssh
# chmod 600 ~/.ssh/id_rsa
 
   

Step 13 Verify that your SSH is working without an authentication or password prompt:


Caution The Fault Management service will not start if SSH prompts for authentication or a password. Be sure to complete all of the following substeps.

a. On node prime-ha-node1.cisco.com, enter:

# ssh root@fm-service.cisco.com
# exit
# ssh root@fm-service
# exit
# ssh root@192.168.1.170
# exit

b. On node prime-ha-node2.cisco.com, enter:

# ssh root@fm-service.cisco.com
# exit
# ssh root@fm-service
# exit
# ssh root@192.168.1.170
# exit

c. If you are prompted for a password, check the permissions of all folders and files that you modified in the preceding steps.

d. If you are prompted to continue connecting, enter yes. (The prompt should appear only the first time you use SSH to connect to the node.)

Step 14 Distribute the virtual machine:

a. Click the running virtual machine and choose Shutdown > Save.

b. On the first node, copy the virtual machine definitions file to the shared directory:

# virsh dumpxml fm_vm > /images/fm_vm.xml
# mkdir /var/images
# cp /images/fm_vm.xml /var/images/fm_vm.xml
# umount /images

c. On the second node, copy the virtual machine definition to the second node:

# mount /dev/mapper/mpathcp1 /images
# virsh define /images/fm_vm.xml
# mkdir /var/images
# cp /images/fm_vm.xml /var/images/fm_vm.xml
# umount /images

Distributing the Node .tar File


Step 1 Insert the Cisco Prime Central 1.2 USB, navigate to the High Availability/Fault Management folder, and locate the primefm_v1.2_ha_node.tar.gz file.

Step 2 Use SSH to connect to the first node.

Step 3 Copy the primefm_v1.2_ha_node.tar.gz file to the first node.

Step 4 Back up the /etc/cluster/ and /images directories.

Step 5 Distribute the file:

# mount /dev/mapper/mpathcp1 /images
# tar -zxf primefm_v1.2_ha_node.tar.gz -C / --owner root --no-same-owner
# chmod 755 /images/*.sh
 
   

Step 6 Edit the fm_status.sh file by changing VM_FQDN to your virtual machine's FQDN:

# vi /images/fm_status.sh
 
   

For example:

VM_FQDN=fm-service.cisco.com
 
   

Distributing the Virtual Machine .tar File


Step 1 Insert the Cisco Prime Central 1.2 USB, navigate to the High Availability/Fault Management folder, and locate the primefm_v1.2_ha_vm.tar.gz file.

Step 2 Mount the shared drive. (The shared storage should still be mounted to the first node. If not, verify that the shared storage is not mounted to the other node; then, mount it to the first node.)

# mount /dev/mapper/mpathcp1 /images
 
   

Step 3 Launch the virtual machine:

# virsh start fm_vm
 
   

Step 4 Use SSH to connect to the virtual machine.

Step 5 Copy the primefm_v1.2_ha_vm.tar.gz file to the virtual machine.

Step 6 Back up the /root/ha-stuff/fm and /usr/local/bin directories.

Step 7 Distribute the file:

# tar -zxf primefm_v1.2_ha_vm.tar.gz -C / --owner root --no-same-owner
# cd /root/ha-stuff/fm
# tar -zxf FM1.2Build.tar.gz
# cp /root/ha-stuff/fm/fm_install.properties /root/ha-stuff/fm/Disk1/InstData/VM/
# chmod -R 755 /root/ha-stuff/fm/Disk*
# chmod 755 /usr/local/bin/*.sh
 
   

Installing Prime Central Fault Management on the Virtual Machine

You can use the GUI to install Fault Management on the virtual machine, or you can install it silently. The following procedures explain both the GUI-based and silent installation options; choose your preferred option.

GUI-Based Installation


Step 1 Use SSH to connect to the virtual machine.

Step 2 Enter:

# cd /root/ha-stuff/fm/Disk1/InstData/VM
 
   

Step 3 Install Prime Central Fault Management:

# ./primefm_v1.2.bin
 
   

At the installer prompts, enter the information described in the Cisco Prime Central 1.2 Quick Start Guide, section "Installing Prime Central Fault Management on the Server."

Step 4 In another terminal window, check the installation process:

# tail -f /opt/primeusr/faultmgmt/install/log/PrimeFM-*.log
 
   

Step 5 After the installation succeeds, use SSH to connect to the Prime Central HA active server and enter:

# clusvadm -Z Prime-Central-service-name
# su - primeusr
# itgctl stop
# itgctl start
# clusvcadm -U Prime-Central-service-name
 
   

Step 6 To test the Prime Central Fault Management installation, open a browser, log into the Prime Central portal, and verify that the Prime Central Fault Management component is running.


Silent Installation


Step 1 Use SSH to connect to the virtual machine.

Step 2 Enter:

# cd /root/ha-stuff/fm/Disk1/InstData/VM
 
   

Step 3 Edit the fm_install.properties file to match your setup.

Step 4 Install Prime Central Fault Management:

# ./primefm_v1.2.bin -i silent -f fm_install.properties
 
   

Step 5 In another terminal window, check the installation process:

# tail -f /opt/primeusr/faultmgmt/install/log/PrimeFM-*.log
 
   

Step 6 The silent installation does not report errors. To see if any errors occurred, check the log files—starting with primefm.log—in the /opt/primeusr/faultmgmt/install/log folder.

Step 7 After the installation succeeds, use SSH to connect to the Prime Central HA active server and enter:

# clusvadm -Z Prime-Central-service-name
# su - primeusr
# itgctl stop
# itgctl start
# clusvcadm -U Prime-Central-service-name
 
   

Step 8 To test the Prime Central Fault Management installation, open a browser, log into the Prime Central portal, and verify that the Prime Central Fault Management component is running.

Step 9 Remove the fm_install.properties file, which contains your server's passwords used during the silent installation.


Setting Up the Fault Management Cluster Service


Step 1 Run the 6.2 cluster workaround on both nodes (see https://access.redhat.com/knowledge/solutions/67583):

# mkdir /var/lib/ricci/.libvirt
# chown ricci:ricci /var/lib/ricci/.libvirt
 
   

Step 2 Verify that the system contains a user named ricci. If the ricci user is missing, enter:

useradd ricci
 
   

Step 3 On both nodes, edit and save the vm.sh agent to allow a longer start time for the Fault Management virtual machine. (If you are using different hardware, you might need to increase the timeout value.)

a. Enter:

# vi /usr/share/cluster/vm.sh

b. Locate the timeout value (in seconds):

<action name="start" timeout="300"/>

c. Change the timeout value to:

<action name="start" timeout="600"/>

Step 4 Modify the /etc/cluster/cluster.conf file and set unique values. The multicast address must be unique per subnet and must be working before you start your cluster. For a tool to verify that your multicast address is correct, see Troubleshooting.

Step 5 Copy the edited cluster.conf file to the /etc/cluster/ directory on both nodes.

If the cluster is not up and running when you change the cluster.conf file, manually copy cluster.conf to the other node; then, restart the cluster:

# rsync -av /etc/cluster/cluster.conf root@prime-ha-node2.cisco.com:/etc/cluster/ 
 
   

Step 6 Validate the cluster.conf file:

# ccs_config_validate
 
   

Step 7 Install luci and ricci (if they are not already installed):

# yum install luci
# yum install ricci
 
   

Step 8 Start the ricci service on both nodes:

# passwd ricci
# service ricci start
 
   

Note Enter the passwd ricci command only once; doing so creates a password for the user ricci.


Step 9 Start the cluster services on both nodes:

# service cman start
# service rgmanager start
 
   

Step 10 (Only if you are using the RHCS luci GUI) On the first node only, start the luci service:

# luci_admin init
# service luci start
 
   

Step 11 (Only if you are using the RHCS luci GUI) Log into luci on the node where you started the luci service; for example:

https://prime-ha-node1.cisco.com:8084
 
   

Checking the Cluster Services


Step 1 Review the cluster log file in /var/log/messages.

Step 2 Check the status of the cluster:

# clustat
 
   

The output is similar to the following:

Cluster Status for bm1cluster @ Tue Jul 30 15:47:46 2013
Member Status: Quorate
 
   
Member Name                         ID    Status
------ ----                         ----  ------
prime-ha-node1.cisco.com            1     Online, Local, rgmanager
prime-ha-node2.cisco.com            2     Online, rgmanager
 
   
Service Name                        Owner (Last)                    State         
------- ----                        ----- ------                    -----         
service:vm1                         prime-ha-node1.cisco.com        started       
 
   

Step 3 Test the Prime Central Fault Management installation:

a. Open a browser, log into the Prime Central portal, and verify that the Prime Central Fault Management component is running.

b. Relocate the virtual machine:

# clusvcadm -r vm1 -m prime-ha-node2.cisco.com

c. After the relocation is complete, reverify that the Fault Management component is running on the Prime Central portal.

Step 4 After the Fault Management service is running in an HA cluster, you cannot restart its components (such as Netcool/Impact, OMNIbus, and Tivoli Common Reporting [TCR]) without first freezing the cluster. After you restart the component, you can unfreeze the cluster.

To restart a Fault Management component:

a. On the active Fault Management node, enter:

# clusvcadm -Z Fault-Management-service-name

b. Use SSH to connect to the Fault Management virtual machine and enter:

# su - primeusr
# fmctl stop
# fmctl start
# exit

c. Use SSH to connect to the active Fault Management node and enter:

# clusvcadm -U Fault-Management-service-name

Next Steps

Complete the following steps on both nodes, except where noted:


Step 1 Configure cman, rgmanager, and ricci to start automatically upon bootup:

# chkconfig cman on
# chkconfig rgmanager on
# chkconfig ricci on
 
   

Step 2 (On the first node only) Configure luci to start automatically upon bootup:

# chkconfig luci on
 
   

Step 3 Verify that the required ports are open. For a list of ports that the Fault Management component requires, see "Prime Central Protocols and Ports" in the Cisco Prime Central 1.2 Quick Start Guide.

Step 4 (On both nodes and on the virtual machine) Enable the firewall:

# service iptables start
# chkconfig iptables on
# service ip6tables start
# chkconfig ip6tables on
 
   

Step 5 Disable SELinux:

# vi /etc/selinux/config
SELINUX=disabled
 
   

5 Troubleshooting

The following troubleshooting steps help solve common problems in an HA configuration.

Problem   The HA installation fails.

Solution   Check the log files to locate the problem and take the appropriate action. Log files contain detailed information about request processing and exceptions and are your best diagnostic tool for troubleshooting. See "Troubleshooting the Installation" in the Cisco Prime Central 1.2 Quick Start Guide.

Problem   Prime Central does not start in a clustered setup.

Solution   Check the /var/log/messages files for failure to either mount the shared storage or add the virtual IP address. If the shared storage failed to mount, shut down the cluster and verify that you can manually add the shared storage to a node. (Be sure to unmount it after your test.)

If the virtual IP address was not added, verify that it is in the same subnet as the nodes and is not in use by any other computer in the network.

If you find that /usr/local/bin/pc.sh start failed, check /usr/local/bin/pc.log and /usr/local/bin/pc-start.log, which will tell you if the database or other Prime Central components failed to start. Then, to determine which component failed to start:

1. Stop the luci, ricci, rgmanager, and cman services on both nodes to shut down the cluster.

2. On the node where you originally installed Prime Central:

a. Mount the shared storage.

b. Add the virtual IP address.

c. Verify that all services have stopped:

/usr/local/bin/pc.sh stop
 
   

d. Enter:

# su - primeusr
# emdbctl -start
# itgctl start
# portalctl start
 
   

e. Check the output from each of the preceding commands to locate the problem.

Problem   You receive the error "<err> 'fsck -p /dev/mapper/mpath2p1' failed, error=4; check /tmp/fs-vmpcfs.fsck.log.mq4986 for errors."

Solution   Enter the following command and reboot when it is finished running:

# fsck -f /dev/mapper/mpath2p1

Problem   You receive the error "Timeout exceeded while waiting for `/images/fm_status.sh'" in /var/log/messages.

Solution   Verify that you can use SSH to connect to each node and virtual machine without an authentication or password prompt. If SSH prompts for authentication or a password, the Prime Central and Fault Management services cannot start.

Problem   Your environment uses the wrong fencing device.

Solution   The examples in this guide use fence_manual and fence_virsh, which are test fencing devices and cannot be used for production. For information about which fencing device to use in your environment, see the Red Hat Enterprise Linux 6 Cluster Administration: Configuring and Managing the High Availability Add-On.

Problem   The cman and rgmanager services do not start.

Solution   Check the log files in /var/log/messages and /var/log/cluster. Use the following tool to verify that your multicast address is correct: http://juliandyke.wordpress.com/2010/12/03/testing-multicasting-for-oracle-11-2-0-2-grid-infrastructure/.

Problem   Cannot perform a live migration.

Solution   To support live migration of the virtual machines, confirm that the shared storage is set up as a clustered file system, such as Global File System (GFS) or CLVM.

Problem   Cannot stop the cluster.

Solution   Use luci or the command line to shut down your cluster:

luci—Select the cluster; then, from the drop-down list, choose Stop this cluster.

Command line—Alternating between the two nodes, shut down the services in the reverse order in which you started them. For example, enter the stop command for rgmanager on node1; then, enter it on node2. Enter the stop command for cman on node1; then, enter it on node2.

# service luci stop
# service ricci stop
# service rgmanager stop
# service cman stop

Problem   When trying to unmount the shared storage, a "device is busy" message is returned.

Solution   Verify that all cluster services have stopped and that you have closed all terminal sessions that are accessing the shared storage location. To determine which user is accessing the shared storage, enter:

# fuser -m -v shared-storage
 
   

For example:

# fuser -m -v /opt/pc

Problem   You do not know if the node can support virtualization.

Solution   Enter:

# egrep '^flags.*(vmx|svm)' /proc/cpuinfo
 
   

If the command returns no output, the node does not support virtualization.

If the command output contains vmx or svm flags, the node supports virtualization. For example:

flags           : fpu vme de pse tsc msr pae mce cx8 apic mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr 
sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good xtopology 
nonstop_tsc aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 cx16 xtpr pdcm dca sse4_1 
sse4_2 popcnt aes lahf_lm ida arat dts tpr_shadow vnmi flexpriority ept vpid

Problem   You receive the error "operation failed: domain 'fm_vm' already exists with uuid..."

Solution   An fm_vm.xml file might already exist on the second node due to a previous attempt to define the file. Do the following:

1. Verify that /images is unmounted from the first node.

2. On the second node (that is, the node on which you did not create the virtual machine), enter:

# mv /etc/libvirt/qemu/fm_vm.xml /tmp
# mount /dev/mapper/mpathcp1 /images 
# virsh define /images/fm_vm.xml
# umount /images

Problem   Cannot test the cluster.conf file.

Solution   Use rg_test commands. For example:

To display the resource rules that rg_test understands, enter:

rg_test rules
 
   

To test a configuration, enter:

rg_test test /etc/cluster/cluster.conf
 
   

To display the start ordering of a service, enter:

rg_test noop /etc/cluster/cluster.conf start service service-name
 
   

To display the stop ordering of a service, enter:

rg_test noop /etc/cluster/cluster.conf stop service service-name

Problem   When you reboot one or both nodes, the node is fenced before it can join the cluster.

Solution   To start up, the node might require an additional fencing delay. Edit your cluster.conf file by increasing the value of the post_join_delay attribute:

<fence_daemon clean_start="0" post_fail_delay="0" post_join_delay="30"/>

Problem   After you relocate the Prime Central service, the integration layer is shown in the Prime Central Suite Monitoring portlet > Applications tab, but its state is Down.

Solution   On servers where the hardware requirements are at or below the minimum for Prime Central high availability, the integration layer requires more time to start up. Do the following:

1. On the active node where Prime Central is running, locate the /opt/pc/primecentral/esb/etc/com.cisco.prime.esb.jms.cfg file.

2. Edit the file by increasing the waitForStart attribute for the jmsvm.internalBrokerURL property. (If the line is commented, uncomment it.)

The default waitForStart value is 10,000 milliseconds; increase it depending on the slowness of your server. For example, to increase the waitForStart value to 30 seconds, enter:

jmsvm.internalBrokerURL=vm://internalBroker?broker.persistent=false&jms.prefetchPolicy.queuePrefetch=1&creat
e=false&waitForStart=30000

Problem   The Prime Central portal does not look correct.

Solution   The cluster manager might have relocated the server. Clear your browser cache and refresh your screen; then, log back into the Prime Central portal.

Problem   You need to restart a Prime Central or Fault Management component in an HA environment.

Solution   Prime Central contains components such as the portal, integration layer, and database. Fault Management contains components such as Netcool/Impact, OMNIbus, and TCR. If you need to perform maintenance on a specific component, you must freeze the HA cluster before you can stop the component. After you restart the component, you can unfreeze the cluster.

To freeze the cluster, enter:

clusvcadm -Z service-name
 
   

To unfreeze the cluster, enter:

clusvcadm -U service-name

Problem   After adding multipath, you cannot see the multipath names when listing the /dev/mapper directory.

Solution   Do the following:

1. Enter:

# vi /etc/multipath.conf
 
   

2. Change the find_multipaths value to no.

3. Enter:

# wq
# service multipathd reload
 
   

You should now see the multipath names.

Problem   You receive the following error while mounting the storage:

[root@prime-central-linux4 ~]# mount /dev/mapper/mpathbp2 /images/
mount: wrong fs type, bad option, bad superblock on /dev/mapper/mpathbp2,
       missing codepage or helper program, or other error
       In some cases useful info is found in syslog - try
       dmesg | tail or so

Solution   Enter:

fsck.ext3 <storage-path>
fsck.ext3 /dev/mapper/mpathbp2

Problem   The fmctl status command shows that Fault Management started in KVM, but hangs in "starting" status in the cluster.

Solution   Check the SSH password-less connection between the two nodes and KVM.

6 Upgrading to Prime Central 1.2 in a Local Redundancy HA Configuration

You must upgrade the server with Red Hat Enterprise Linux 5.5 to 5.8 before upgrading Prime Central.

To upgrade from Prime Central 1.1 to 1.2 in a local redundancy HA configuration:


Step 1 Shut down the cluster.

Step 2 Insert the Cisco Prime Central 1.2 USB, navigate to the High Availability/Prime Central folder, and locate the primecentral_v1.2_ha_vm.tar.gz file.

Step 3 Use SSH to connect to the first node.

Step 4 Copy the primecentral_v1.2_ha_vm.tar.gz file to the first node.

Step 5 Back up the following directories on both nodes:

/root/ha-stuff/pc

/usr/local/bin

Step 6 Distribute the file:

# tar -zxf primecentral_v1.2_ha_vm.tar.gz -C / --owner root --no-same-owner
# chmod 755 /root/ha-stuff/pc/*
# chmod 755 /usr/local/bin/*
 
   

Step 7 On the first node only, do the following:

a. Mount the shared partitions:

# mount /dev/mapper/mpath2p1 /opt/pc

b. Add a virtual IP cluster service address for the Prime Central service:

# ip addr add 192.168.1.130 dev eth0

c. Update the install.properties file and verify that all required properties have values. Review the comments at the top of the install.properties file for details.


Note To install Prime Central silently, you must edit the /root/ha-stuff/pc/install.properties file. See "Sample install.properties Files" in the Cisco Prime Central 1.2 Quick Start Guide.


d. Install Prime Central:

# cd /root/ha-stuff/pc
# ./PrimeCentral.sh 192.168.1.130 node's-root-password second-node-IP-address

Note You run the PrimeCentral.sh script by adding the preceding command-line parameters. If you do not add the command-line parameters, you are prompted for the required data.


e. In another terminal window, check the upgrade process:

# tail -f /tmp/primecentral_install.log

f. After the upgrade succeeds, start Prime Central:

# /usr/local/bin/pc.sh start

g. Verify that Prime Central is running correctly; then, stop it:

# /usr/local/bin/pc.sh stop

h. Remove the virtual IP addresses:

# ip addr del 192.168.1.130 dev eth0

i. Unmount the shared partitions:

# umount /opt/pc

When the upgrade completes, the log files are available in ~/upgrade/1.1.0.0-1.2.0.0/upgrade.log.


7 Upgrading to Prime Central Fault Management 1.2 in a Local Redundancy HA Configuration

You must upgrade the server with Red Hat Enterprise Linux 5.5 to 5.8 before upgrading Prime Central Fault Management.

To upgrade from Prime Central Fault Management 1.1 to 1.2 in a local redundancy HA configuration:


Step 1 Shut down the cluster.

Step 2 Insert the Cisco Prime Central 1.2 USB, navigate to the High Availability/Fault Management folder, and locate the primefm_v1.2_ha_node.tar.gz file.

Step 3 Use SSH to connect to the first node.

Step 4 Copy the primefm_v1.2_ha_node.tar.gz file to the first node.

Step 5 Back up the /etc/cluster/ and /images directories.

Step 6 Distribute the file:

# mount /dev/mapper/mpathcp1 /images
# tar -zxf primefm_v1.2_ha_node.tar.gz -C / --owner root --no-same-owner
# chmod 755 /images/*.sh
 
   

Step 7 Edit the fm_status.sh file by changing VM_FQDN to your virtual machine's FQDN:

# vi /images/fm_status.sh
 
   

For example:

VM_FQDN=fm-service.cisco.com
 
   

Step 8 Return to the High Availability/Fault Management folder and locate the primefm_v1.2_ha_vm.tar.gz file.

Step 9 Mount the shared drive. (The shared storage should still be mounted to the first node. If not, verify that the shared storage is not mounted to the other node; then, mount it to the first node.)

# mount /dev/mapper/mpathcp1 /images
 
   

Step 10 Launch the virtual machine:

# virsh start fm_vm
 
   

Step 11 Use SSH to connect to the virtual machine.

Step 12 Copy the primefm_v1.2_ha_vm.tar.gz file to the virtual machine.

Step 13 Back up the /root/ha-stuff/fm and /usr/local/bin directories.

Step 14 Distribute the file:

# tar -zxf primefm_v1.2_ha_vm.tar.gz -C / --owner root --no-same-owner
# cd /root/ha-stuff/fm
# tar -zxf FM1.2Build.tar.gz
# cp /root/ha-stuff/fm/fm_install.properties /root/ha-stuff/fm/Disk1/InstData/VM/
# chmod -R 755 /root/ha-stuff/fm/Disk*
# chmod 755 /usr/local/bin/*.sh
 
   

Step 15 Enter:

# cd /root/ha-stuff/fm/Disk1/InstData/VM
 
   

Step 16 Edit the fm_install.properties file to match your setup.

Step 17 Enter:

# ./primefm_v1.2.bin -i silent -f fm_install.properties
 
   

Step 18 In another terminal window, check the upgrade process:

# tail -f /opt/primeusr/faultmgmt/install/log/PrimeFM-*.log
 
   

Step 19 To see if any errors occurred, check the log files—starting with primefm.log—in the /opt/primeusr/faultmgmt/upgrade/logs folder.

Step 20 After the upgrade succeeds, use SSH to connect to the Prime Central HA active server and enter:

# clusvadm -Z Prime-Central-service-name
# su - primeusr
# itgctl stop
# itgctl start
# clusvcadm -U Prime-Central-service-name
 
   

Step 21 To test the Prime Central Fault Management upgrade, open a browser, log into the Prime Central portal, and verify that the Prime Central Fault Management component is running.

Step 22 Remove the fm_install.properties file, which contains your server's passwords.


8 Uninstalling Prime Central Fault Management


Note If you are also uninstalling Prime Central, you must uninstall the Fault Management component first.



Step 1 From the Prime Central portal, choose Administration > System > Suite Monitoring > Applications tab, and remove Fault Management.

Step 2 Use SSH to connect to the Prime Central active node and do the following:

a. Freeze the Prime Central cluster:

clusvcadm -Z service-name

b. Restart the integration layer:

# su - primeusr
# itgctl stop
# itgctl start

c. Unfreeze the Prime Central cluster:

clusvcadm -U service-name

Step 3 Use SSH to connect to the Prime Central Fault Management active node and freeze the Fault Management cluster service:

clusvcadm -Z service-name
 
   

Step 4 Use SSH to connect to the Prime Central Fault Management virtual machine and do the following:

a. Navigate to the /var/adm/cisco/uninstall/Uninstall_Prime_Central_Fault_Management folder.

The uninstall folder contains the installvariables.properties file.

b. Uninstall Prime Central Fault Management:

./Uninstall_Prime_Central_Fault_Management -i silent

The uninstallation log files are available at /var/adm/cisco/uninstall/PrimeFM-uninstall.log-time-stamp.

Step 5 Stop and disable the Fault Management cluster service on both nodes:

# service luci stop
# service ricci stop
# service rgmanager stop
# service cman stop
 
   

9 Uninstalling Prime Central


Step 1 Stop and disable the Prime Central cluster service on both nodes:

# service luci stop
# service ricci stop
# service rgmanager stop
# service cman stop
 
   

Step 2 Mount and add the virtual IP address to the node that was used for the Prime Central installation:

# ip addr add 192.168.1.130 dev eth0
# mount /dev/mapper/mpath2p1 /opt/pc
 
   

Step 3 Uninstall the application:

a. As the root user, log into the Prime Central server. (If you logged in previously as a nonroot user, enter the su - command to become the root user.)

b. Uninstall Prime Central:

# cd /root/ha-stuff/pc
# ./UninstallPrimeCentral.sh 192.168.1.120

In the preceding command, 192.168.1.120 is the IP address of the second node.

The uninstallation log files are available at /var/adm/cisco/uninstall/UNINSTALL_LOG_time-stamp.

Step 4 Unmount and remove the virtual IP address:

# ip addr del 192.168.1.130 dev eth0
# umount /opt/pc