Installation and Configuration Guide for the Cisco NAM 2220 Appliance
BIOS Settings
Downloads: This chapterpdf (PDF - 353.0KB) The complete bookPDF (PDF - 6.09MB) | Feedback

BIOS Settings

Table Of Contents

BIOS Settings


BIOS Settings


This appendix lists the BIOS settings used in the Cisco NAM 2220 appliance. The appliance uses BIOS version 88.


Note We recommend that you do not change any of these BIOS settings.


Table E-1 Cisco 2220 NAM Appliance BIOS Settings 

Type
CMOS Setup Menu Contents
Setting

Main

Quiet Boot

Enabled

POST Error Pause

Disabled

System Date

Use CLI clock set command to set current date and time.

System Time

Advanced—Processor

Core Frequency

n/a

System Bus Frequency

n/a

Enhanced Speed Step

Enabled

Core-Multi Processing

Enabled

Virtualization Technology

Disabled

Simulated MSI Support

Enabled

Execute Disable Bit

Enabled

Hardware Prefetcher

Enabled

Adjacent Cache Line Prefetch

Enabled

Processor Retest

Disabled

Advanced—Memory

Memory Mirroring Possible

Display only

Memory Sparing Possible

Select Memory RAS Configuration

RAS Disabled

Snoop Filter

Enabled

FSB High Bandwidth Optimization

Disabled

Advanced—ATE Controller

Onboard PATA Controller

Enabled

Onboard SATA Controller

Enabled

SATA Mode

Enhanced

AHCI Mode

Disabled

Configure SATA as RAID

Disabled

Advanced—Mass Storage Controller

SAS Controller

Enabled

Hardware-RAID Activation Key Present

Always installed

Advanced—Serial Port

Serial Port A Enable

Enabled

Address

3F8

IRQ

4

Serial Port B Enable

Enabled

Address

2F8

IRQ

3

Advanced—USB Configuration

USB Controller

Enabled

Legacy USB Support

Enabled

Port 60/64 Emulation

Disabled

Device Reset Timeout

20 seconds

USB 2.0 Controller

Enabled

Advanced—PCI

Memory Mapped I/O Start Address

2.5 GB

Memory Mapped I/O Above
4 GB

Disabled

Onboard Video

Enabled

Dual Monitor Video

Disabled

Onboard NIC ROM

Enabled

I/O Module NIC ROM

Enabled

Intel I/OAT

Enabled

Advanced—System Acoustic and Performance Configuration

Set Fan Profile

Performance

Altitude

301 m - 900 m

Advanced—Server

Admin Password

User Password

Front Panel Lockout

Disabled

Server Management

Assert NMI on SERR

Enabled

Assert NMI on PERR

Enabled

Resume on AC Power Loss

Last State

Clear system Event Log

Disabled

FRB-2 Enable

Enabled

OS Boot Watchdog Timer

Disabled

OS Boot Watchdog Timer Policy

Linked to above.

Plug & Play BMC Detection

Enabled

Server Management—Console Redirection

Console Redirection

Serial Port B

Flow Control

None

Baud Rate

9.6 K

Terminal Type

VT-100

Boot Options

Boot Timeout

10 seconds

Boot Option #1

CD

Boot Option #2

Hard Drive

Boot Option #3

[EFI Shell]

Boot Manager

CD

 
 

Hard Drive

 
 

[EFI Shell]

 

Error Manager