Cisco IOS XR System Error Message Reference Guide, Release 4.2.x
Platform Messages
Downloads: This chapterpdf (PDF - 5.3MB) The complete bookPDF (PDF - 68.41MB) | Feedback

Platform Messages

Table Of Contents

Platform Messages

AFMON_EA_OOR Messages

AFMON_EA_VERIFY Messages

AFMON Messages

AHCI Messages

ALPHA_DISPLAY Messages

APIV Messages

ARB Messages

ASM Messages

ASR9k_IFLX Messages

AVSM_APIV Messages

BCM_LOGGER Messages

BCM_SWITCH Messages

BP_SERVER Messages

BPE Messages

BRIDGE Messages

CAIBIST Messages

CANB_SERVER Messages

CARD Messages

CARDMGR Messages

CBC Messages

CCI_HAL_SATORI Messages

CCI_SSTAR Messages

CCTL_ENS Messages

CCTL Messages

CE_SWITCH Messages

CEMGBL Messages

CETHHA Messages

CFP Messages

CGV6_SERVICES Messages

CHP Messages

CIH Messages

CLKCTRL_T Messages

CLKCTRL Messages

CLUSTER_UPGRADE Messages

COMMON Messages

CONCERTO Messages

CPU_CTRL Messages

CPUCTRL_SIP700_DLL Messages

CPUCTRL_SIP700 Messages

CPUCTRL Messages

CPUCTRLLIB Messages

CROSSBAR Messages

DC_SERVICE_SRVR Messages

DIAGS Messages

DISCOVERY Messages

DISK_DRIVER Messages

DISKCAM Messages

DMAC Messages

DRP_PAIRING_CLIENT Messages

DRP_PAIRING Messages

DSC_CTRL Messages

DSC Messages

DSCMEDIA Messages

EIO Messages

EMUX Messages

ENV_AGT_DLL Messages

ENVMON_MON Messages

ENVMON Messages

EOBC Messages

ETH_SRVR_API Messages

ETH_SRVR Messages

ETHER_CTRL_DLL Messages

ETHER_CTRL Messages

FABARBITER Messages

FABIO Messages

FABMGR Messages

FABRIC_CTRL Messages

FAN Messages

FAULT_MGR_CLIENT Messages

FAULT_MGR_EH Messages

FAULT_MGR Messages

FAULT Messages

FCA Messages

FDIAGS Messages

FFQ Messages

FIB_DBG Messages

FIB_IDB_LIB Messages

FIB_LTRACE Messages

FPD_BURNER Messages

FPGAMGR Messages

FSYNC Messages

G_PLIM_QOS Messages

GE_DMAC Messages

GSR_FIB_STATS_API Messages

GSR_IPV4_EA Messages

GSR_IPv6_EA Messages

GSR_lc_exmem Messages

GSR_LC_PM Messages

GSR_LIB Messages

GSR_MPLS_EA Messages

GSR_PRP_PM Messages

GSR_TUNNEL_EA Messages

GT_I2C Messages

HAL_COMM_DBG Messages

HBAGENT Messages

HD Messages

HFR_IP_EA Messages

HFR_IPV6_EA Messages

HFR_L2FIB_METRO_SHOW Messages

HFR_LCPM_SHOW Messages

HFR_MPLS_EA Messages

HFR_PM_CS Messages

HFR_PM_SHOW Messages

HFR_PM_TEST Messages

HFR_PM Messages

HFR_SPP Messages

HFR_TUNNEL_EA Messages

HORSE Messages

HPI Messages

hytop Messages

I2C_DRV Messages

I2C_MASTERSHIP Messages

I2C Messages

I2CCTRL Messages

ILITE Messages

IMUX Messages

INTCTRL Messages

INTEG_SWITCH Messages

INV_AGENT Messages

INV Messages

INVMGR Messages

IPCP_SRVR Messages

JBI Messages

KD Messages

LAMPTEST Messages

LC_CPIDB Messages

LC_CPPIF Messages

LC_CPUCTRL Messages

LC_FPGA_UPGRADE Messages

LC_PIDB Messages

LC_QFPCPUCTRL Messages

LDA Messages

LIB_ISOLATION Messages

libpcmcia_ide Messages

libpcmcia_linux Messages

LIC_UDI Messages

MACE Messages

MANSDORF Messages

MBI_HELLO Messages

MBI_LIB_ACCESS Messages

MBI_LIB Messages

MBIMGR Messages

MBUS Messages

MCE Messages

MCU Messages

MDIO Messages

MGID_ERROR Messages

MGID_OOR Messages

MLAN Messages

MLRMGR Messages

MPC8641 Messages

MSM Messages

NFEA_HW_PROG Messages

NFEA_PAL Messages

NIRVANA Messages

NP Messages

NPUXBAR_BRIDGE Messages

NVEDGE_DATA Messages

OBFL_PD Messages

OBFL Messages

obfl Messages

OBFL Messages

obfl Messages

OBFL Messages

obfl Messages

OBFL Messages

obfl Messages

OBFL Messages

obfl Messages

OIRD Messages

P40X0_DPAA Messages

PBR_EA_OOR Messages

PBR_EA_VERIFY Messages

PCIE_CLIENT Messages

PCIE_HAL Messages

PCIE_SWITCH Messages

PCIE Messages

PCIER Messages

PCIMGR Messages

PCMCIA Messages

PCMCIAD Messages

PCTL Messages

PDMA_SPP Messages

PEX Messages

PEX8111 Messages

PEX8508 Messages

PEXMGR Messages

PEXRC Messages

PFM Messages

PLAT_BMADJ Messages

PLAT_FIB_EA Messages

PLAT_FIB_ECD Messages

PLAT_FIB_GTRIE Messages

PLAT_FIB_HAL Messages

PLAT_FIB_MPLS Messages

PLAT_FIB_RP Messages

PLAT_FIB Messages

PLAT_ICPE_EA_DEBUG Messages

PLAT_ICPE_EA_LTRACE Messages

PLAT_ICPE_EA Messages

PLAT_L2FIB_ATOM Messages

PLAT_L2FIB_BRIDGING Messages

PLAT_L2FIB_COMMON Messages

PLAT_L2FIB_DEBUG Messages

PLAT_L2FIB_L2TP Messages

PLAT_L2FIB_LOCSW Messages

PLAT_L2FIB_LTRACE Messages

PLAT_L2FIB_MAC_CACHE Messages

PLAT_L2FIB_METRO Messages

PLAT_L2FIB_POGO Messages

PLAT_L2FIB_RP Messages

PLAT_L2FIB_SNOOP Messages

PLAT_L2FIB_VPLS Messages

PLAT_L2FIB Messages

PLAT_L2VPN_DEBUG Messages

PLAT_L2VPN_FGID Messages

PLAT_L2VPN_LTRACE Messages

PLAT_L2VPN Messages

PLAT_MCAST Messages

PLAT_THOR_L2FIB_ATOM Messages

PLAT_THOR_L2FIB_DEBUG Messages

PLAT_THOR_L2FIB_LOCSW Messages

PLAT_THOR_L2FIB_LTRACE Messages

PLAT_THOR_L2FIB_VPLS Messages

PLAT_THOR_L2FIB Messages

PLAT_UDI_MGR Messages

PLAT_V6FIB_RP Messages

PLATFORM_ASR9K_LIB Messages

PLATFORM_HFR_LIB Messages

PLDMGR Messages

PLIM_16P_OC48 Messages

PLIM_IPC Messages

PLIM_SERVICES Messages

PLIM_UPGRADE_FPD Messages

PLMGR_OBJ_LIB Messages

PLMGR_BAG_OPS Messages

PLU Messages

PLUTLU Messages

PM_OS Messages

PORT_CFG Messages

POWERMGR Messages

preroute Messages

PRM_VERIFY Messages

PRM Messages

PROCMGR_DLL Messages

PROCMGR Messages

PRP_HW Messages

PRP3_FABIO Messages

PRP3_SLR_FABIO Messages

PSARB Messages

PSARBLC Messages

PUNT_INFRA Messages

PUNT_SWITCH Messages

PUNT Messages

PWHE_EA_PD Messages

PWR_MGMT Messages

PWR_SUPPLY Messages

PWRMON Messages

QFPCPUBridgeFPGA Messages

QOSHAL Messages

QSFP_PLUS Messages

RCCLIB Messages

REDDRV Messages

REEP Messages

ROM_UPGRADE_LIB Messages

ROMMON_BURNER Messages

RSP_CPUCTRL Messages

RUNA Messages

RWMGR Messages

SATORI Messages

SCC Messages

SCF Messages

SE_P2MP_SRVR Messages

SERDES Messages

SERVICE_AGENT Messages

SFP Messages

SHELFMGR_API Messages

SHELFMGR_HAL Messages

SHELFMGR Messages

SHELFMGRV2 Messages

SHOW_VERSION_CMD Messages

SIM_INFRA Messages

SIM_IPC Messages

SIM_SE Messages

SL Messages

SMITH Messages

SPA_JBI Messages

SPAN_EA Messages

SPAQFPBridgeCtrl Messages

SPB_I2C Messages

SPENET Messages

SPMCE Messages

SQUID_LOADER Messages

STP_SHIM Messages

SYSLDR_LC Messages

SYSLDR_RP Messages

SYSLDR Messages

TFQ Messages

TIMESYNC_CLIENT Messages

TIMESYNC Messages

TIPCP Messages

TLU Messages

TOPMGR Messages

TSEC_SPP Messages

TSEC Messages

TUNL_GRE_EA_PD Messages

TUNNEL_GRE_EA Messages

TURBO Messages

UDLD Messages

UPGRADE_FPD Messages

UPGRADE Messages

USB Messages

VCDMA Messages

VIC Messages

VKG_AMCC2035 Messages

VKG_BCM8705 Messages

VKG_CPP_LCPM_SHOW Messages

VKG_CPP_PM_TEST Messages

VKG_CPP_PM Messages

VKG_IP_EA Messages

VKG_IPV4_EA Messages

VKG_IPV6_EA Messages

VKG_LCPM_SHOW Messages

VKG_MPLS_EA Messages

VKG_PM_TEST Messages

VKG_PM Messages

VKG_PMLIB_CLIENT Messages

VKG_PMLIB_IM Messages

VKG_PMLIB Messages

VKG_SERDES Messages

VKG_SIS Messages

WD_PLATFORM Messages

WDMBI Messages

XBAR Messages

XCVR Messages

XFP Messages

ZENJF Messages

ZL Messages

ZPLL_API Messages


Platform Messages


This section contains all Platform related System Error Messages, such as shelf magr, chassis, env ctrl, and so forth.

AFMON_EA_OOR Messages

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_OOR-4-NP_FLOWS_OOR_GREEN Performance Traffic Monitoring: Monitored flows on LC [unsigned int] no longer at maximum capacity

Explanation    Performance traffic monitoring has cleared an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a LC is no longer at maximum.

Recommended Action    None

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_OOR-4-NP_FLOWS_OOR_GREEN Performance Traffic Monitoring: Monitored flows on NP [unsigned int] no longer at maximum capacity

Explanation    Performance traffic monitoring has cleared an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a NP is no longer at maximum.

Recommended Action    None

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_OOR-4-NP_FLOWS_OOR_RED Performance Traffic Monitoring: Maximum monitored flows ([unsigned int]) reached on LC [unsigned int]

Explanation    Performance traffic monitoring has encountered an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a LC has reached maximum capacity. New flows will no longer be learnt

Recommended Action    Reduce the number of flows being monitored on the LC. This can be done by 1) Modifying ACL: (a) Remove the performance traffic service policy from the interface (b) Modify the ACL used in the service policy to be more specific to match a smaller set of flows to be monitored (c) Reapply the service policy to the interface 2) Moving monitored flows to a different interface on a different LC

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_OOR-4-NP_FLOWS_OOR_RED Performance Traffic Monitoring: Maximum monitored flows ([unsigned int]) reached on NP [unsigned int]

Explanation    Performance traffic monitoring has encountered an out-of-resource condition. Performance traffic monitoring process on the linecard has detected that the number of flows being monitored on a NP has reached maximum capacity. New flows will no longer be learnt

Recommended Action    Reduce the number of flows being monitored on the NP. This can be done by 1) Modifying ACL: (a) Remove the performance traffic service policy from the interface (b) Modify the ACL used in the service policy to be more specific to match a smaller set of flows to be monitored (c) Reapply the service policy to the interface 2) Moving monitored flows to a different interface on a different NP

AFMON_EA_VERIFY Messages

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_VERIFY-6-POLICY_ERROR Performance traffic service policy verification failed, error [chars]: [chars]

Explanation    Peformance traffic service policy verification encountered the specified error

Recommended Action    Correct the performance traffic service policy

Error Message     
 
    
    
   

%PLATFORM-AFMON_EA_VERIFY-6-POLICY_ERROR Performance traffic service policy verification failed, error [chars]: [chars]

Explanation    Peformance traffic service policy verification encountered the specified error

Recommended Action    Correct the performance traffic service policy

AFMON Messages

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-AVL_TREE_CORRUPT Corruption detected in AVL tree for [chars]

Explanation    During restart, corruption was detected in the AVL tree. Tree is reinitialized as part of recovery, some interval history during this time could be lost for the flow

Recommended Action    No action is required if it is flow tree. Process will try to recover by recreating the tree. In case of interface tree, remove all the policy config on the LC. If that fail, reload the LC If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-EA_DEBUG_INIT_FAIL Failed to initialise debug infra within AFMon EA. Error: [chars]

Explanation    Debug initialization failed within EA. Debugs may not be printed

Recommended Action    No action is required. Process will be automatically restarted.

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-EA_LTRACE_INIT_FAIL Failed to initialise ltrace infra within AFMon EA. Error [chars]

Explanation    Ltrace initialization failed within EA. Ltraces may not be printed

Recommended Action    No action is required. Process will be automatically restarted.

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-EA_POL_MOD_ROLLBACK_FAIL Error encountered during Rollback phase of policy modification on interface: [chars] (ifh: [hex]), Error: [chars]

Explanation    AFMon EA encountered an error during rollback phase of policy modification on an interface. In this condition, h/w programming of the policy may not be in sync with policy configuration.

Recommended Action    Remove the Vidmon policy on the interface for which the this error message is printed and then re-apply the policy

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-ERR_EVENT_ATTACH Failed to attach event to event manager: [chars]

Explanation    Failed to attach event to event manager.

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-ERR_EVENT_INIT Failed to initialize event manager event: [chars]

Explanation    Failed to initialize event manager event.

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-ERR_EVM_CREATE Failed to setup event manager

Explanation    Failed to setup event manager.

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-FAM_CONNECT_FAIL FAM connection failed - [chars]

Explanation    Connection to FAM process failed during AFMon EA process init. This would lead to an inablility of AFMon EA to receive flow updates from the hardware

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-IM_CONNECT_FAIL Server connection failed - [chars]. Error code - [chars]

Explanation    Connection to IM server failed during AFMon EA process init. This would lead to an inablility of AFMon EA to process CAPS from AFMon MA and to a potential disconnect between the hardware/software views of the configured afmon policies on the system.

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-3-MAX_FLOW_LIMIT LC has reached maximum limit for flows, current [dec] maximum allowed [dec]

Explanation    Software enforces a limit of 1.5 times the maximum number of flows permitted on a LC. When this limit is reached, no more new flows can be added unless the current flow count comes under the limit

Recommended Action    Reduce the number of flows in the LC If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%PLATFORM-AFMON-4-ERR_EVM_EVENT_BLOCK Unrecoverable error in event loop. Error: [chars]

Explanation    An error (other than EINTR) occured in the event loop. The process has exited and restarted.

Recommended Action    No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

AHCI Messages

Error Message     
 
    
    
   

%PLATFORM-AHCI-2-DEV_HD0_NOT_RESPONDING HD0 device not responding

Explanation    SATA HD0 device not responding

Recommended Action    Please attempt the following: If dual RSP, and the problem is on the active RSP, issue 'redundancy switchover' If the problem is on the standby/simplex RSP: Restart low level ahci driver via ksh, 'process restart devb-ahci' Failing which, Reload RSP If problem persists, SATA HD0 devices have to be replaced If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-AHCI-2-DEV_HD1_NOT_RESPONDING HD1 device not responding

Explanation    SATA HD1 device not responding

Recommended Action    Please attempt the following: If dual RSP, and the problem is on the active RSP, issue 'redundancy switchover' If the problem is on the standby/simplex RSP: Restart low level ahci driver via ksh, 'process restart devb-ahci' Failing which, Reload RSP If problem persists, SATA HD1 devices have to be replaced If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ALPHA_DISPLAY Messages

Error Message     
 
    
    
   

%PLATFORM-ALPHA_DISPLAY-3-INIT_ERROR Process Initialization Failed: ([chars]%s)

Explanation    The alphadisplay process failed to initialize. The alphadisplay process controls the 8 characters alphanumeric LEDs on the bottom of all 12000 series line and route processor cards (excluding SIP cards). It provides for the configuration of custom messages as well as the reading of the current output both through CLI and XML. %s - indicates the reason for the failure. There are 2 types of possible failures, these include: - Event Manager Creation Failure - SYSDB Initialization Failure %s - is the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process alphadisplay' to verify that the process is up and running. If it is still non-operational, try doing try doing 'process restart alphadisplay' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ALPHA_DISPLAY-6-CHANGE Alpha display on node [chars] changed to [chars] in state [chars]

Explanation    Message to indicate that alpha-display was updated with new string or state.

Recommended Action    None.

Error Message     
 
    
    
   

%PLATFORM-ALPHA_DISPLAY-6-CHANGE Alpha display on node [chars] changed to [chars] in state [chars]

Explanation    Message to indicate that alpha-display was updated with new string or state.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-ALPHA_DISPLAY-6-CHANGE Alpha display on node [chars] changed to [chars] in state [chars]

Explanation    Message to indicate that alpha-display was updated with new string or state.

Recommended Action    None.

Error Message     
 
    
    
   

%PLATFORM-ALPHA_DISPLAY-7-EVENT_ERROR Event Failure: ([chars])

Explanation    The alphadisplay process received a bad event. The alphadisplay process controls the 8 characters alphanumeric LEDs on the bottom of all 12000 series line and route processor cards (excluding SIP cards). It provides for the configuration of custom messages as well as the reading of the current output both through CLI and XML. %s - is the decoded error reason

Recommended Action    Monitor the event messages. The alphadisplay process will handle the failure gracefully but if they continually appear on the console, try doing 'process restart alphadisplay' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

APIV Messages

Error Message     
 
    
    
   

%PLATFORM-APIV-3-MODULE_INCOMPATIBLE APIV module [chars] is incompatible

Explanation    APIV module version negotiation failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-APIV-3-SW_ERROR [chars]

Explanation    An internal software error has occurred for the specified APIV module

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-APIV-5-API_INCOMPATIBLE Message [dec] in APIV module [chars] is incompatible (reason: [chars])

Explanation    The APIV module message version negotiation failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ARB Messages

Error Message     
 
    
    
   

%PLATFORM-ARB-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    Arbiter driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    Arbiter driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    Arbiter driver encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    Arbiter driver encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-5-ERR_CONT Continuing execution: [chars]: Caused by [chars]

Explanation    This message indicates an error occurred beyond which execution of the arbiter driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-5-ERR_CONT Continuing execution: [chars]: Caused by [chars]

Explanation    This message indicates an error occurred beyond which execution of the arbiter driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EVM_CREATE Event Manager create failed for [chars]. Reason: [chars]

Explanation    Arbiter driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EVM_CREATE Event Manager create failed for [chars]. Reason: [chars]

Explanation    Arbiter driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]. Reason: [chars]

Explanation    Arbiter driver Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]. Reason: [chars]

Explanation    Arbiter driver Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EXIT Exit on error: [chars]: Caused by [chars]

Explanation    An error occurred in arbiter driver which requires exiting (and, hence, restarting) the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_EXIT Exit on error: [chars]: Caused by [chars]

Explanation    An error occurred in arbiter driver which requires exiting (and, hence, restarting) the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed. Reason: [chars]

Explanation    Arbiter driver Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed. Reason: [chars]

Explanation    Arbiter driver Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_LWM_REPLY An error occurred during LWM message reply. Reason: [chars]

Explanation    Arbiter driver LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ARB-7-ERR_LWM_REPLY An error occurred during LWM message reply. Reason: [chars]

Explanation    Arbiter driver LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ASM Messages

Error Message     
 
    
    
   

%PLATFORM-ASM-0-FAULT_RECOVERY_ERR The fault recovery procedure for the FromFab component of the fabric driver has failed. The root fault was: [chars]

Explanation    When a hardware fault occurs and the device driver cannot correct it, the Platform Manager is required to reset the ASICs. This error indicates that the Platform Manager failed to reset the ASICs and the hardware on the PRP may not be in an operational state. This condition affects the functionality of the entire router. %s is the Interrupt Source.

Recommended Action    If the system has not failed over automatically and a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0 ' where x is the slot of route processor that generated the error. If no redundant RP is configured you will need to reboot the router by issuing the reload command. Call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-0-SW_INIT_ERR A software error occurred in the FrFab driver component during initialization: [chars]

Explanation    The fabricq_prp_driver process which controls the FromFab driver on the route processor has failed to initalize and cannot recover automatically. This is a software fault. The FromFab driver controls the hardware that receives data from the fabric. It runs in the fabricq_prp_driver process. An unrecoverable failure of the fabricq_prp_driver process may prevent this route processor card from communicating with other cards on the chassis. %s indicates the type failure

Recommended Action    Restart the fabricq_prp_driver process with the following command: 'process restart fabricq_prp_driver' If the error message appears again, then: if a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0 ' where x is the slot of route processor that generated the error. if no redundant RP is configured you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-BADDESC_ERR Assembler detected a bad descriptor error: Data [hex]

Explanation    Assembler detected a bad descriptor in the free queue. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-CRC_ERR assembler dll: block: [chars], entity: [chars] had CRC error, count: [dec]

Explanation    PII block got a packet from the entity mentioned above with a CRC error.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-DEVICE_HALT FFQ: device halted, sub-block: [chars], halted entity: [chars]

Explanation    FFQ, ASIC got halted. The halted block and its parent block are provided

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FATAL assembler dll: fatal error encountered, reason equals [chars]

Explanation    iqm, assembler dll manager encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FATAL_2 assembler dll: fatal error encountered, reason equals [chars], errno equals [dec]

Explanation    assembler encountered a fatal error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FIA_INTFERR Assembler detected a FIA interface error: Data [hex]

Explanation    Assembler detected an error with the fia interface. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FIA_PARITYERR Assembler detected a FIA parity error: Data [hex]

Explanation    A parity error has been detected on the assembler to fia interface. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FQEMPTY_ERR Assembler detected that a free queue is empty

Explanation    The assembler component has detected that one of the free queues used to buffer packets coming from the fabric into the route processor is empty.

Recommended Action    The system will most likely recover from this error automatically. No intervention is required. If this error is reported frequently you may want to call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-FQEMPTY_ERR Assembler detected a free queue empty error: Data [hex]

Explanation    Assembler detected a that the free queue is empty. The hex number indicates the error cause register value.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-GEN_INFO assembler dll: general information,[chars]

Explanation    The ASM's informational message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-HWINIT_INCOMPLETE assembler dll: hardware initialization not complete

Explanation    hardware init is not complete.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-INFO assembler dll: service degrading error, reason equals [chars]

Explanation    The assembler encountered an error that would lead to degraded service.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-INTR_ENABLE_FAIL assembler dll: intr enable at addr: [hex] mask: [hex] failed.

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-INTR_STATUS_GET_ERR assembler dll: intr status get failed for: [chars]@[hex], rc equals [dec]

Explanation    Hardware register read failed.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-MALLOC_FAILED assembler dll: fatal memory allocation error for [dec] bytes

Explanation    ASM encountered a fatal memory allocation error

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-NOT_AVAILABLE assembler dll: asic is not available

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-NOT_OPERATIONAL assembler dll: asic is not operational, state: [dec]

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-NOT_YET_IMPLEMENTED assembler dll: this function [chars] is not yet implemented

Explanation    FFQ, assembler dll , a function is not implemented.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-3-RESET_ERR Assembler is being reset because of too many errors.

Explanation    Assembler software driver is seeing too many errors that indicated a problem with the hardware. Some of the error logs prior to this message should indicate the errors that lead to this reset.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-4-BADDESC_ERR Assembler detected a bad descriptor.

Explanation    Assembler detected a bad descriptor in the free queue. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a hardware problem on the route processor card.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error occurs increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-ASM-6-UNHANDLED_HALT assembler dll: halt not handled, parent: [chars], child: [chars], intr: [dec]

Explanation    Hardware halt is not handled.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-ASM-6-UNHANDLED_INTR assembler dll: intr not handled, parent: [chars], child: [chars], group id: [dec], intr: [dec]

Explanation    Hardware interrupt is not handled in the code, need to implement.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

ASR9k_IFLX Messages

Error Message     
 
    
    
   

%PLATFORM-ASR9k_IFLX-5-FRONT_PORT_SHARING_WARNING PLATFORM-IFLX: [chars]

Explanation    Only 10/100M IFLX front port sharing mode is supported. No explicit blocking

Recommended Action    Do not config unsupported IFLX front port sharing mode

AVSM_APIV Messages

Error Message     
 
    
    
   

%PLATFORM-AVSM_APIV-3-REGISTRATION_TIMEOUT Timeout ([dec] seconds) waiting for APIV modules registration.

Explanation    The registration of APIV modules has not completed. The specified timeout period has reached and is this event will be considered as a failure that will trigger a reload of the affected card.

Recommended Action    Contact Cisco TAC to diagnose the problem.

Error Message     
 
    
    
   

%PLATFORM-AVSM_APIV-4-MOD_NOT_REGISTERED The [chars] APIV module (module ID equals [dec]) was not registered in time to receive version negotiation event notification.

Explanation    This event will cause the module to fail in APIV versioning negotiation operation.

Recommended Action    Contact Cisco TAC to diagnose the problem.

BCM_LOGGER Messages

Error Message     
 
    
    
   

%PLATFORM-BCM_LOGGER-6-LOGGING_DEVICE Node: [chars]: [chars] will be used for storing control ethernet logs. Current logs are under [chars] directory.

Explanation    This is an informational message to indicate the location of for es_persist, bcm.log, stp.log and stp_shim.log are.

Recommended Action    Do nothing

Error Message     
 
    
    
   

%PLATFORM-BCM_LOGGER-7-COPY_FAILED Copying of log file to [chars] failed. err equals [dec], status equals [dec]. Restarting to recover.

Explanation    This is an informational message to indicate that copying a log file to the storage device indicated has failed. This could be because the device was being formatted. The process will restart to recover.

Recommended Action    Do nothing

Error Message     
 
    
    
   

%PLATFORM-BCM_LOGGER-7-DIR_NOT_FOUND [chars] directory not found.

Explanation    This is an informational message to indicate that a log directory in the storage device is not found. This could be because the device was being formatted. The process will restart to recover.

Recommended Action    Do nothing

Error Message     
 
    
    
   

%PLATFORM-BCM_LOGGER-7-NO_STORAGE_DEVICE_FOUND Copying of control-ethernet log files to persistent storage is suspended because no persistent storage device (harddisk/PCMCIA disk) found

Explanation    The service that copies /tmp/bcm.log, stp.log, es_persist to persistent storage, did not find any of harddisk, disk0, disk1 available

Recommended Action    See if any of harddisk, disk0, disk1 are accessible on the RP. If they are accessible, restart bcm_logger.

BCM_SWITCH Messages

Error Message     
 
    
    
   

%PLATFORM-BCM_SWITCH-2-LINK_SHUT_DOWN Spanning Tree Port [chars] state changed to ADMIN_DOWN

Explanation    Spanning Tree Port's state change by manual intervention.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-BCM_SWITCH-2-LINK_STATE_CHANGE Spanning Tree Port [chars] state changed to [chars]

Explanation    Spanning Tree Port's state change indication.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-BCM_SWITCH-2-MMU_ERR Control Ethernet Intra-rack Switch [dec] detected MMU error

Explanation    The switch encountered a MMU error. MMU errors can affect traffic forwarding in the switch.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BCM_SWITCH-2-PCI_ERR PCI fatal error seen on switch [dec] DMA channel [dec] type [chars]

Explanation    The switch encountered a PCI error during a DMA transaction.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BCM_SWITCH-6-GBP_FULL Control Ethernet Intra-rack Switch [dec] detected Memory full condition

Explanation    The switch encountered a memory full condition. Normally this error is not expected. As per the spec, this situation should fix itself. The ports will drop packets in ingress if the situation persists.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

BP_SERVER Messages

Error Message     
 
    
    
   

%PLATFORM-BP_SERVER-3-ERR_DSC_ELECTION This RP detected more than 2 RPs (active/standby) inserted in the chassis.

Explanation    When more than 2 RPs (active/standby) are used in the same chassis, one must be elected as the dSC, the master of the chassis. In order to select which RP will become the dSC, insert only the RPs that will be part of the Owner Logical Router (maximum of 2 RPs). Once these RPs are fully booted, you may insert other RPs as required and assign them to manage logical routers. At this point, chassis mastership has been determined and subsequent power-cycle of the chassis will support multiple RPs with no problem.

Recommended Action    Eject RPs that are unused or not in the Owner Logical Router. Ensure there are no more than 2 RPs inserted. Reload the RPs. Wait for console prompt. Insert other RP cards and load them as required.

Error Message     
 
    
    
   

%PLATFORM-BP_SERVER-3-ERR_INIT_DSC Failed to learn if we are running on the DSC ([chars])

Explanation    This process needs to know if it runs on the DSC or standby DSC. An error occured while trying to get the information from the DSC process. The process will voluntary exit, and should be restarted.

Recommended Action    Verify that the DSC process is running using 'show process' command.

Error Message     
 
    
    
   

%PLATFORM-BP_SERVER-3-ERR_MAC_BLK_SIZE Backplane NVRAM contains MAC address info field [hex] which is invalid. Please rectify this problem to ensure quality operation of your router

Explanation    There is a MAC address block field in the backplane NVRAM. If the MAC address block field is invalid, there is the possibility of corrupted backplane NVRAM or incompatibility with the software

Recommended Action    Verify that the chassis is supported with the version of software. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered.

Error Message     
 
    
    
   

%PLATFORM-BP_SERVER-3-INVALID_BP_VERSION Backplane NVRAM contains Backplane Version number [dec] which is invalid. Please rectify this problem to ensure quality operation of your router

Explanation    There is a Backplane Version field in the backplane NVRAM. If the Backplane Version field is invalid, there is the possibility of corrupted backplane NVRAM or incompatibility with the software

Recommended Action    Verify that the chassis is supported with the version of software. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered.

Error Message     
 
    
    
   

%PLATFORM-BP_SERVER-3-INVALID_CHASSIS_MODEL Backplane NVRAM contains chassis model number [dec] which is invalid. Please rectify this problem to ensure quality operation of your router

Explanation    Backplane NVRAM contains the chassis model number which the software relies on for chassis identification. This is a complaint about an invalid chassis model number is stored in backplane NVRAM. Software will try its best to use the CSC card in the chassis to determine the chassis model.

Recommended Action    Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/pcgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the information you have gathered.

BPE Messages

Error Message     
 
    
    
   

%PLATFORM-BPE-3-ERR [chars], [chars]([hex])

Explanation    An error occurred in BPE Driver which requires exiting (and, hence, restarting) the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    BPE Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    BPE encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-5-ERR_CONT Continuing execution: [chars]: Caused by [chars]

Explanation    This message indicates an error occurred beyond which execution of the bpe_driver may continue, attempting to effect recovery or work-around internally, minimizing loss of information/functionality.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-5-INFO [chars]

Explanation    This message logs an informational message.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-DEBUG_CONT Continuing execution: [chars]

Explanation    This message indicates an condition occurred beyond which execution of the bpe_driver may continue

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-ERR_EVM_CREATE Event Manager create failed for [chars]. Reason: [chars]

Explanation    BPE Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]. Reason: [chars]

Explanation    BPE Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-ERR_EXIT Exit on error: [chars]: Caused by [chars]

Explanation    An error occurred in BPE Driver which requires exiting (and, hence, restarting) the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed. Reason: [chars]

Explanation    BPE Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BPE-7-ERR_LWM_REPLY An error occurred during LWM message reply. Reason: [chars]

Explanation    bpe LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

BRIDGE Messages

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_BUS_BIT_STUCK_0 DDR bus data bit stuck-0

Explanation    DDR bus databit stuck on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_BUS_BIT_STUCK_1 DDR bus data bit stuck-1

Explanation    DDR bus databit stuck on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_BUS_BIT_STUCK_2 DDR bus data bit stuck-2

Explanation    DDR bus databit stuck on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_BUS_BIT_STUCK_3 DDR bus data bit stuck-3

Explanation    DDR bus databit stuck on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_LOSS_OF_SYNC_0 DDR interface loss of sync-0

Explanation    Loss of sync on DDR interface on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_LOSS_OF_SYNC_1 DDR interface loss of sync-1

Explanation    Loss of sync on DDR interface on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_LOSS_OF_SYNC_2 DDR interface loss of sync-2

Explanation    Loss of sync on DDR interface on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-DDR_LOSS_OF_SYNC_3 DDR interface loss of sync-3

Explanation    Loss of sync on DDR interface on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_FIA2BR_0 FIFO-0 FIA to bridge-0 overflow

Explanation    FIFO-0 FIA to bridge instance-0 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_FIA2BR_1 FIFO-0 FIA to bridge-1 overflow

Explanation    FIFO-0 FIA to bridge instance-1 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_FIA2BR_2 FIFO-0 FIA to bridge-2 overflow

Explanation    FIFO-0 FIA to bridge instance-2 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_FIA2BR_3 FIFO-0 FIA to bridge-3 overflow

Explanation    FIFO-0 FIA to bridge instance-3 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_NPU2BR_0 FIFO-0 NPU to bridge-0 overflow

Explanation    FIFO-0 NPU to bridge instance-0 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_NPU2BR_1 FIFO-0 NPU to bridge-1 overflow

Explanation    FIFO-0 NPU to bridge instance-1 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_NPU2BR_2 FIFO-0 NPU to bridge-2 overflow

Explanation    FIFO-0 NPU to bridge instance-2 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_0_OFLOW_NPU2BR_3 FIFO-0 NPU to bridge-3 overflow

Explanation    FIFO-0 NPU to bridge instance-3 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_FIA2BR_0 FIFO-1 FIA to bridge-0 overflow

Explanation    FIFO-1 FIA to bridge instance-0 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_FIA2BR_1 FIFO-1 FIA to bridge-1 overflow

Explanation    FIFO-1 FIA to bridge instance-1 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_FIA2BR_2 FIFO-1 FIA to bridge-2 overflow

Explanation    FIFO-1 FIA to bridge instance-2 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_FIA2BR_3 FIFO-1 FIA to bridge-3 overflow

Explanation    FIFO-1 FIA to bridge instance-3 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_NPU2BR_0 FIFO-1 NPU to bridge-0 overflow

Explanation    FIFO-1 NPU to bridge instance-0 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_NPU2BR_1 FIFO-1 NPU to bridge-1 overflow

Explanation    FIFO-1 NPU to bridge instance-1 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_NPU2BR_2 FIFO-1 NPU to bridge-2 overflow

Explanation    FIFO-1 NPU to bridge instance-2 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-FIFO_1_OFLOW_NPU2BR_3 FIFO-1 NPU to bridge-3 overflow

Explanation    FIFO-1 NPU to bridge instance-3 overflow.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_0_TX_FIFO_OFLOW_0 MAC on NPU-0 transmit fifo overflow - 0

Explanation    MAC on NPU-0 had transmit fifo overflow on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_0_TX_FIFO_OFLOW_1 MAC on NPU-0 transmit fifo overflow - 1

Explanation    MAC on NPU-0 had transmit fifo overflow on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_0_TX_FIFO_OFLOW_2 MAC on NPU-0 transmit fifo overflow - 2

Explanation    MAC on NPU-0 had transmit fifo overflow on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_0_TX_FIFO_OFLOW_3 MAC on NPU-0 transmit fifo overflow - 3

Explanation    MAC on NPU-0 had transmit fifo overflow on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_1_TX_FIFO_OFLOW_0 MAC on NPU-1 transmit fifo overflow - 0

Explanation    MAC on NPU-1 had transmit fifo overflow on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_1_TX_FIFO_OFLOW_1 MAC on NPU-1 transmit fifo overflow - 1

Explanation    MAC on NPU-1 had transmit fifo overflow on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_1_TX_FIFO_OFLOW_2 MAC on NPU-1 transmit fifo overflow - 2

Explanation    MAC on NPU-1 had transmit fifo overflow on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-MAC_1_TX_FIFO_OFLOW_3 MAC on NPU-1 transmit fifo overflow - 3

Explanation    MAC on NPU-1 had transmit fifo overflow on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_EGR_Q_ERR_0 NPU-0 egress queue error - 0

Explanation    Egress queue error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_EGR_Q_ERR_1 NPU-0 egress queue error - 1

Explanation    Egress queue error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_EGR_Q_ERR_2 NPU-0 egress queue error - 2

Explanation    Egress queue error on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_EGR_Q_ERR_3 NPU-0 egress queue error - 3

Explanation    Egress queue error on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_LOSS_OF_SYNC_0 NPU-0 interface loss of sync-0

Explanation    Loss of sync on NPU-0 interface on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_LOSS_OF_SYNC_1 NPU-0 interface loss of sync-1

Explanation    Loss of sync on NPU-0 interface on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_LOSS_OF_SYNC_2 NPU-0 interface loss of sync-2

Explanation    Loss of sync on NPU-0 interface on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_LOSS_OF_SYNC_3 NPU-0 interface loss of sync-3

Explanation    Loss of sync on NPU-0 interface on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_0 NPU-0 scheduler mem parity error - 0

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_1 NPU-0 scheduler mem parity error - 1

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_2 NPU-0 scheduler mem parity error - 2

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_3 NPU-0 scheduler mem parity error - 3

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_PLL_LOCK_0 NPU-0 XAUI PLL not locked on bridge - 0

Explanation    NPU-0 XAUI PLL not locked on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_PLL_LOCK_1 NPU-0 XAUI PLL not locked on bridge - 1

Explanation    NPU-0 XAUI PLL not locked on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_PLL_LOCK_2 NPU-0 XAUI PLL not locked on bridge - 2

Explanation    NPU-0 XAUI PLL not locked on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_PLL_LOCK_3 NPU-0 XAUI PLL not locked on bridge - 3

Explanation    NPU-0 XAUI PLL not locked on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_0 NPU-0 XAUI not ready on bridge - 0

Explanation    NPU-0 XAUI not ready on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_1 NPU-0 XAUI not ready on bridge - 1

Explanation    NPU-0 XAUI not ready on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_2 NPU-0 XAUI not ready on bridge - 2

Explanation    NPU-0 XAUI not ready on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_3 NPU-0 XAUI not ready on bridge - 3

Explanation    NPU-0 XAUI not ready on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_EGR_Q_ERR_0 NPU-1 egress queue error - 0

Explanation    Egress queue error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_EGR_Q_ERR_1 NPU-1 egress queue error - 1

Explanation    Egress queue error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_EGR_Q_ERR_2 NPU-1 egress queue error - 2

Explanation    Egress queue error on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_EGR_Q_ERR_3 NPU-1 egress queue error - 3

Explanation    Egress queue error on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_LOSS_OF_SYNC_0 NPU-1 interface loss of sync-0

Explanation    Loss of sync on NPU-1 interface on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_LOSS_OF_SYNC_1 NPU-1 interface loss of sync-1

Explanation    Loss of sync on NPU-1 interface on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_LOSS_OF_SYNC_2 NPU-1 interface loss of sync-2

Explanation    Loss of sync on NPU-1 interface on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_LOSS_OF_SYNC_3 NPU-1 interface loss of sync-3

Explanation    Loss of sync on NPU-1 interface on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_SCH_MEMP_ERR_0 NPU-1 scheduler mem parity error - 0

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_SCH_MEMP_ERR_1 NPU-1 scheduler mem parity error - 1

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_SCH_MEMP_ERR_2 NPU-1 scheduler mem parity error - 2

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_SCH_MEMP_ERR_3 NPU-1 scheduler mem parity error - 3

Explanation    Scheduler Hang, Sram or egress mid-fifo parity error on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_PLL_LOCK_0 NPU-1 XAUI PLL not locked on bridge - 0

Explanation    NPU-1 XAUI PLL not locked on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_PLL_LOCK_1 NPU-1 XAUI PLL not locked on bridge - 1

Explanation    NPU-1 XAUI PLL not locked on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_PLL_LOCK_2 NPU-1 XAUI PLL not locked on bridge - 2

Explanation    NPU-1 XAUI PLL not locked on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_PLL_LOCK_3 NPU-1 XAUI PLL not locked on bridge - 3

Explanation    NPU-1 XAUI PLL not locked on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_0 NPU-1 XAUI not ready on bridge - 0

Explanation    NPU-1 XAUI not ready on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_1 NPU-1 XAUI not ready on bridge - 1

Explanation    NPU-1 XAUI not ready on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_2 NPU-1 XAUI not ready on bridge - 2

Explanation    NPU-1 XAUI not ready on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_3 NPU-1 XAUI not ready on bridge - 3

Explanation    NPU-1 XAUI not ready on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_DATABIT_STUCK_0 QDR memory data bit stuck-0

Explanation    QDR memory databit stuck on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_DATABIT_STUCK_1 QDR memory data bit stuck-1

Explanation    QDR memory databit stuck on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_DATABIT_STUCK_2 QDR memory data bit stuck-2

Explanation    QDR memory databit stuck on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_DATABIT_STUCK_3 QDR memory data bit stuck-3

Explanation    QDR memory databit stuck on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_M_FREE_EMPTY_0 Multicast free pages empty - 0

Explanation    Multicast free pages empty on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_M_FREE_EMPTY_1 Multicast free pages empty - 1

Explanation    Multicast free pages empty on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_M_FREE_EMPTY_2 Multicast free pages empty - 2

Explanation    Multicast free pages empty on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_M_FREE_EMPTY_3 Multicast free pages empty - 3

Explanation    Multicast free pages empty on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_0 QDR memory ECC failure on bridge-0

Explanation    QDR memory ECC failure on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_1 QDR memory ECC failure on bridge-1

Explanation    QDR memory ECC failure on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_2 QDR memory ECC failure on bridge-2

Explanation    QDR memory ECC failure on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_3 QDR memory ECC failure on bridge-3

Explanation    QDR memory ECC failure on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_SELFTEST_FAIL_0 QDR memory self test failure on bridge-0

Explanation    QDR memory self test failure on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_SELFTEST_FAIL_1 QDR memory self test failure on bridge-1

Explanation    QDR memory self test failure on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_SELFTEST_FAIL_2 QDR memory self test failure on bridge-2

Explanation    QDR memory self test failure on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-QDR_MEM_SELFTEST_FAIL_3 QDR memory self test failure on bridge-3

Explanation    QDR memory self test failure on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. Please verify the bridge FPGA is loaded properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-REG_ACCESS_FAIL_0 Register access failure on bridge-0

Explanation    Register access failure on bridge instance-0.

Recommended Action    Please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-REG_ACCESS_FAIL_1 Register access failure on bridge-1

Explanation    Register access failure on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-REG_ACCESS_FAIL_2 Register access failure on bridge-2

Explanation    Register access failure on bridge instance-2.

Recommended Action    Please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-REG_ACCESS_FAIL_3 Register access failure on bridge-3

Explanation    Register access failure on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR1_0 State machine-0 error-1 on bridge-0

Explanation    State machine - 0 ran into error-1 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR1_1 State machine-0 error-1 on bridge-1

Explanation    State machine - 0 ran into error-1 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR1_2 State machine-0 error-1 on bridge-2

Explanation    State machine - 0 ran into error-1 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR1_3 State machine-0 error-1 on bridge-3

Explanation    State machine - 0 ran into error-1 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR2_0 State machine-0 error-2 on bridge-0

Explanation    State machine - 0 ran into error-2 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR2_1 State machine-0 error-2 on bridge-1

Explanation    State machine - 0 ran into error-2 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR2_2 State machine-0 error-2 on bridge-2

Explanation    State machine - 0 ran into error-2 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR2_3 State machine-0 error-2 on bridge-3

Explanation    State machine - 0 ran into error-2 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR3_0 State machine-0 error-3 on bridge-0

Explanation    State machine - 0 ran into error-3 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR3_1 State machine-0 error-3 on bridge-1

Explanation    State machine - 0 ran into error-3 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR3_2 State machine-0 error-3 on bridge-2

Explanation    State machine - 0 ran into error-3 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_0_ERR3_3 State machine-0 error-3 on bridge-3

Explanation    State machine - 0 ran into error-3 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR1_0 State machine-1 error-1 on bridge-0

Explanation    State machine - 1 ran into error-1 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR1_1 State machine-1 error-1 on bridge-1

Explanation    State machine - 1 ran into error-1 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR1_2 State machine-1 error-1 on bridge-2

Explanation    State machine - 1 ran into error-1 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR1_3 State machine-1 error-1 on bridge-3

Explanation    State machine - 1 ran into error-1 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR2_0 State machine-1 error-2 on bridge-0

Explanation    State machine - 1 ran into error-2 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR2_1 State machine-1 error-2 on bridge-1

Explanation    State machine - 1 ran into error-2 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR2_2 State machine-1 error-2 on bridge-2

Explanation    State machine - 1 ran into error-2 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR2_3 State machine-1 error-2 on bridge-3

Explanation    State machine - 1 ran into error-2 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR3_0 State machine-1 error-3 on bridge-0

Explanation    State machine - 1 ran into error-3 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR3_1 State machine-1 error-3 on bridge-1

Explanation    State machine - 1 ran into error-3 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR3_2 State machine-1 error-3 on bridge-2

Explanation    State machine - 1 ran into error-3 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-STATEMC_1_ERR3_3 State machine-1 error-3 on bridge-3

Explanation    State machine - 1 ran into error-3 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAN_SYNC_0 XAUI to NPU-0 chan sync error on bridge-0

Explanation    XAUI to NPU-0 chan sync error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAN_SYNC_1 XAUI to NPU-0 chan sync error on bridge-1

Explanation    XAUI to NPU-0 chan sync error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAN_SYNC_2 XAUI to NPU-0 chan sync error on bridge-2

Explanation    XAUI to NPU-0 chan sync error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAN_SYNC_3 XAUI to NPU-0 chan sync error on bridge-3

Explanation    XAUI to NPU-0 chan sync error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAR_ALIGN_0 XAUI to NPU-0 char alignment error on bridge-0

Explanation    XAUI to NPU-0 char alignment error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAR_ALIGN_1 XAUI to NPU-0 char alignment error on bridge-1

Explanation    XAUI to NPU-0 char alignment error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAR_ALIGN_2 XAUI to NPU-0 char alignment error on bridge-2

Explanation    XAUI to NPU-0 char alignment error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_CHAR_ALIGN_3 XAUI to NPU-0 char alignment error on bridge-3

Explanation    XAUI to NPU-0 char alignment error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_0 XAUI to NPU-0 MGT code violation on bridge-0

Explanation    XAUI to NPU-0 MGT code violation on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_1 XAUI to NPU-0 MGT code violation on bridge-1

Explanation    XAUI to NPU-0 MGT code violation on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_2 XAUI to NPU-0 MGT code violation on bridge-2

Explanation    XAUI to NPU-0 MGT code violation on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3 XAUI to NPU-0 MGT code violation on bridge-3

Explanation    XAUI to NPU-0 MGT code violation on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_0 XAUI to NPU-0 Rx alignment loss - 0

Explanation    Rx alignment loss on XAUI to NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_1 XAUI to NPU-0 Rx alignment loss - 1

Explanation    Rx alignment loss on XAUI to NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_2 XAUI to NPU-0 Rx alignment loss - 2

Explanation    Rx alignment loss on XAUI to NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3 XAUI to NPU-0 Rx alignment loss - 3

Explanation    Rx alignment loss on XAUI to NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_0 XAUI to NPU-0 state error on bridge-0

Explanation    XAUI to NPU-0 state error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_1 XAUI to NPU-0 state error on bridge-1

Explanation    XAUI to NPU-0 state error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_2 XAUI to NPU-0 state error on bridge-2

Explanation    XAUI to NPU-0 state error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_3 XAUI to NPU-0 state error on bridge-3

Explanation    XAUI to NPU-0 state error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_0 XAUI to NPU-0 tx fifo overflow - 0

Explanation    XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_1 XAUI to NPU-0 tx fifo overflow - 1

Explanation    XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_2 XAUI to NPU-0 tx fifo overflow - 2

Explanation    XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_0_TX_FIFO_OFLOW_3 XAUI to NPU-0 tx fifo overflow - 3

Explanation    XAUI interface to NPU-0 reported tx fifo overflow on bridge instance - 3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAN_SYNC_0 XAUI to NPU-1 chan sync error on bridge-0

Explanation    XAUI to NPU-1 chan sync error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAN_SYNC_1 XAUI to NPU-1 chan sync error on bridge-1

Explanation    XAUI to NPU-1 chan sync error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAN_SYNC_2 XAUI to NPU-1 chan sync error on bridge-2

Explanation    XAUI to NPU-1 chan sync error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAN_SYNC_3 XAUI to NPU-1 chan sync error on bridge-3

Explanation    XAUI to NPU-1 chan sync error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAR_ALIGN_0 XAUI to NPU-1 char alignment error on bridge-0

Explanation    XAUI to NPU-1 char alignment error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAR_ALIGN_1 XAUI to NPU-1 char alignment error on bridge-1

Explanation    XAUI to NPU-1 char alignment error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAR_ALIGN_2 XAUI to NPU-1 char alignment error on bridge-2

Explanation    XAUI to NPU-1 char alignment error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_CHAR_ALIGN_3 XAUI to NPU-1 char alignment error on bridge-3

Explanation    XAUI to NPU-1 char alignment error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_MGT_CV_0 XAUI to NPU-1 MGT code violation on bridge-0

Explanation    XAUI to NPU-1 MGT code violation on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_MGT_CV_1 XAUI to NPU-1 MGT code violation on bridge-1

Explanation    XAUI to NPU-1 MGT code violation on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_MGT_CV_2 XAUI to NPU-1 MGT code violation on bridge-2

Explanation    XAUI to NPU-1 MGT code violation on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_MGT_CV_3 XAUI to NPU-1 MGT code violation on bridge-3

Explanation    XAUI to NPU-1 MGT code violation on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_0 XAUI to NPU-1 Rx alignment loss - 0

Explanation    Rx alignment loss on XAUI to NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_1 XAUI to NPU-1 Rx alignment loss - 1

Explanation    Rx alignment loss on XAUI to NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_2 XAUI to NPU-1 Rx alignment loss - 2

Explanation    Rx alignment loss on XAUI to NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_RX_ALIGN_LOSS_3 XAUI to NPU-1 Rx alignment loss - 3

Explanation    Rx alignment loss on XAUI to NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_STAT_VEC_0 XAUI to NPU-1 state error on bridge-0

Explanation    XAUI to NPU-1 state error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_STAT_VEC_1 XAUI to NPU-1 state error on bridge-1

Explanation    XAUI to NPU-1 state error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_STAT_VEC_2 XAUI to NPU-1 state error on bridge-2

Explanation    XAUI to NPU-1 state error on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_STAT_VEC_3 XAUI to NPU-1 state error on bridge-3

Explanation    XAUI to NPU-1 state error on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_0 XAUI to NPU-1 tx fifo overflow - 0

Explanation    XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_1 XAUI to NPU-1 tx fifo overflow - 1

Explanation    XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_2 XAUI to NPU-1 tx fifo overflow - 2

Explanation    XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_1_TX_FIFO_OFLOW_3 XAUI to NPU-1 tx fifo overflow - 3

Explanation    XAUI interface to NPU-1 reported tx fifo overflow on bridge instance - 3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_A_DATABUS_STUCK_0 XAUI-A databus stuck-0

Explanation    XAUI-A databus stuck on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_A_DATABUS_STUCK_1 XAUI-A databus stuck-1

Explanation    XAUI-A databus stuck on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_A_DATABUS_STUCK_2 XAUI-A databus stuck-2

Explanation    XAUI-A databus stuck on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-1-XAUI_A_DATABUS_STUCK_3 XAUI-A databus stuck-3

Explanation    XAUI-A databus stuck on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_0_RX_FRAME_ERR_0 MAC on NPU-0 receive frame error - 0

Explanation    MAC on NPU-0 received an errored frame interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_0_RX_FRAME_ERR_1 MAC on NPU-0 receive frame error - 1

Explanation    MAC on NPU-0 received an errored frame interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_0_RX_FRAME_ERR_2 MAC on NPU-0 receive frame error - 2

Explanation    MAC on NPU-0 received an errored frame interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_0_RX_FRAME_ERR_3 MAC on NPU-0 receive frame error - 3

Explanation    MAC on NPU-0 received an errored frame interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_1_RX_FRAME_ERR_0 MAC on NPU-1 receive frame error - 0

Explanation    MAC on NPU-1 received an errored frame interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_1_RX_FRAME_ERR_1 MAC on NPU-1 receive frame error - 1

Explanation    MAC on NPU-1 received an errored frame interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_1_RX_FRAME_ERR_2 MAC on NPU-1 receive frame error - 2

Explanation    MAC on NPU-1 received an errored frame interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MAC_1_RX_FRAME_ERR_3 MAC on NPU-1 receive frame error - 3

Explanation    MAC on NPU-1 received an errored frame interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MCAST_PAGE_ERR_0 Multicast page error on bridge-0

Explanation    Multicast page error on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MCAST_PAGE_ERR_1 Multicast page error on bridge-1

Explanation    Multicast page error on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MCAST_PAGE_ERR_2 Multicast page error on bridge-2

Explanation    Multicast page error on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-MCAST_PAGE_ERR_3 Multicast page error on bridge-3

Explanation    Multicast page error on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_DIP2_ERR_0 NPU-0 egress flow control DIP2 parity error - 0

Explanation    Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_DIP2_ERR_1 NPU-0 egress flow control DIP2 parity error - 1

Explanation    Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_DIP2_ERR_2 NPU-0 egress flow control DIP2 parity error - 2

Explanation    Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_DIP2_ERR_3 NPU-0 egress flow control DIP2 parity error - 3

Explanation    Egress flow control DIP2 parity error on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_OOS_0 NPU-0 egress flow control out-of-sync - 0

Explanation    Egress flow control out-of-sync on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_OOS_1 NPU-0 egress flow control out-of-sync - 1

Explanation    Egress flow control out-of-sync on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_OOS_2 NPU-0 egress flow control out-of-sync - 2

Explanation    Egress flow control out-of-sync on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_0_FC_OOS_3 NPU-0 egress flow control out-of-sync - 3

Explanation    Egress flow control out-of-sync on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_DIP2_ERR_0 NPU-1 egress flow control DIP2 parity error - 0

Explanation    Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_DIP2_ERR_1 NPU-1 egress flow control DIP2 parity error - 1

Explanation    Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_DIP2_ERR_2 NPU-1 egress flow control DIP2 parity error - 2

Explanation    Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_DIP2_ERR_3 NPU-1 egress flow control DIP2 parity error - 3

Explanation    Egress flow control DIP2 parity error on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_OOS_0 NPU-1 egress flow control out-of-sync - 0

Explanation    Egress flow control out-of-sync on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_OOS_1 NPU-1 egress flow control out-of-sync - 1

Explanation    Egress flow control out-of-sync on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_OOS_2 NPU-1 egress flow control out-of-sync - 2

Explanation    Egress flow control out-of-sync on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-NPU_1_FC_OOS_3 NPU-1 egress flow control out-of-sync - 3

Explanation    Egress flow control out-of-sync on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-QDR_M_WR_ERR_0 Multicast write when free page fifo empty - 0

Explanation    Multicast write when free page fifo empty on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-QDR_M_WR_ERR_1 Multicast write when free page fifo empty - 1

Explanation    Multicast write when free page fifo empty on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-QDR_M_WR_ERR_2 Multicast write when free page fifo empty - 2

Explanation    Multicast write when free page fifo empty on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-2-QDR_M_WR_ERR_3 Multicast write when free page fifo empty - 3

Explanation    Multicast write when free page fifo empty on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_0_FIA_0 Checksum error - 0 from FIA on bridge-0

Explanation    Checksum error - 0 from FIA on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_0_FIA_1 Checksum error - 0 from FIA on bridge-1

Explanation    Checksum error - 0 from FIA on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_0_FIA_2 Checksum error - 0 from FIA on bridge-2

Explanation    Checksum error - 0 from FIA on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_0_FIA_3 Checksum error - 0 from FIA on bridge-3

Explanation    Checksum error - 0 from FIA on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_1_FIA_0 Checksum error - 1 from FIA on bridge-0

Explanation    Checksum error - 1 from FIA on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_1_FIA_1 Checksum error - 1 from FIA on bridge-1

Explanation    Checksum error - 1 from FIA on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_1_FIA_2 Checksum error - 1 from FIA on bridge-2

Explanation    Checksum error - 1 from FIA on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CHKSUM_ERR_1_FIA_3 Checksum error - 1 from FIA on bridge-3

Explanation    Checksum error - 1 from FIA on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_FIA_0 CRC error - 0 from FIA on bridge-0

Explanation    CRC error - 0 from FIA on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_FIA_1 CRC error - 0 from FIA on bridge-1

Explanation    CRC error - 0 from FIA on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_FIA_2 CRC error - 0 from FIA on bridge-2

Explanation    CRC error - 0 from FIA on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_FIA_3 CRC error - 0 from FIA on bridge-3

Explanation    CRC error - 0 from FIA on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_NPU_0 CRC error from NPU-0 on bridge-0

Explanation    CRC error from NPU-0 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_NPU_1 CRC error from NPU-0 on bridge-1

Explanation    CRC error from NPU-0 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_NPU_2 CRC error from NPU-0 on bridge-2

Explanation    CRC error from NPU-0 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_0_NPU_3 CRC error from NPU-0 on bridge-3

Explanation    CRC error from NPU-0 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_FIA_0 CRC error - 1 from FIA on bridge-0

Explanation    CRC error - 1 from FIA on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_FIA_1 CRC error - 1 from FIA on bridge-1

Explanation    CRC error - 1 from FIA on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_FIA_2 CRC error - 1 from FIA on bridge-2

Explanation    CRC error - 1 from FIA on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_FIA_3 CRC error - 1 from FIA on bridge-3

Explanation    CRC error - 1 from FIA on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_NPU_0 CRC error from NPU-1 on bridge-0

Explanation    CRC error from NPU-1 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_NPU_1 CRC error from NPU-1 on bridge-1

Explanation    CRC error from NPU-1 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_NPU_2 CRC error from NPU-1 on bridge-2

Explanation    CRC error from NPU-1 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-CRC_ERR_1_NPU_3 CRC error from NPU-1 on bridge-3

Explanation    CRC error from NPU-1 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_CRC_ERR_0 Decoder A CRC Error - 0

Explanation    Decoder A CRC error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_CRC_ERR_1 Decoder A CRC Error - 1

Explanation    Decoder A CRC error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_FRAME_ERR_0 Decoder A Framing Error - 0

Explanation    Decoder A framing error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_FRAME_ERR_1 Decoder A Framing Error - 1

Explanation    Decoder A framing error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_PKT_LEN_ERR_0 Decoder A Packet Length Error - 0

Explanation    Packet with invalid length encountered by decoder A on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_PKT_LEN_ERR_1 Decoder A Packet Length Error - 1

Explanation    Packet with invalid length encountered by decoder A on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_PWM_ERR_0 Decoder A PWM Error - 0

Explanation    PWM bit level decoder error on decoder A on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_PWM_ERR_1 Decoder A PWM Error - 1

Explanation    PWM bit level decoder error on decoder A on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_TYPE_DISABLED_0 Decode A Type Disabled - 0

Explanation    Pkt received for timestamp type disabled on Decoder A on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-DEC_A_TYPE_DISABLED_1 Decode A Type Disabled - 1

Explanation    Pkt received for timestamp type disabled on Decoder A on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_LONG_PKT_0_0 Egress long packet detected - 0,0

Explanation    Egress long packet detected on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_LONG_PKT_0_1 Egress long packet detected - 0,1

Explanation    Egress long packet detected on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_LONG_PKT_1_0 Egress long packet detected - 1,0

Explanation    Egress long packet detected on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_LONG_PKT_1_1 Egress long packet detected - 1,1

Explanation    Egress long packet detected on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_NPH_LEN_0_0 Egress invalid length detected - 0,0

Explanation    Invalid egress NPH length detected on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_NPH_LEN_0_1 Egress invalid length detected - 0,1

Explanation    Invalid egress NPH length detected on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_NPH_LEN_1_0 Egress invalid length detected - 1,0

Explanation    Invalid egress NPH length detected on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_NPH_LEN_1_1 Egress invalid length detected - 1,1

Explanation    Invalid egress NPH length detected on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_DATA_FIFO_OFLOW_0_0 Egress seg data fifo overflow - 0,0

Explanation    Egress seg data fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_DATA_FIFO_OFLOW_0_1 Egress seg data fifo overflow - 0,1

Explanation    Egress seg data fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_DATA_FIFO_OFLOW_1_0 Egress seg data fifo overflow - 1,0

Explanation    Egress seg data fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_DATA_FIFO_OFLOW_1_1 Egress seg data fifo overflow - 1,1

Explanation    Egress seg data fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_EXT_FIFO_OFLOW_0_0 Egress seg hdr ext fifo overflow - 0,0

Explanation    Egress seg hdr ext fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_EXT_FIFO_OFLOW_0_1 Egress seg hdr ext fifo overflow - 0,1

Explanation    Egress seg hdr ext fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_EXT_FIFO_OFLOW_1_0 Egress seg hdr ext fifo overflow - 1,0

Explanation    Egress seg hdr ext fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_EXT_FIFO_OFLOW_1_1 Egress seg hdr ext fifo overflow - 1,1

Explanation    Egress seg hdr ext fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_FIFO_OFLOW_0_0 Egress seg hdr fifo overflow - 0,0

Explanation    Egress seg hdr fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_FIFO_OFLOW_0_1 Egress seg hdr fifo overflow - 0,1

Explanation    Egress seg hdr fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_FIFO_OFLOW_1_0 Egress seg hdr fifo overflow - 1,0

Explanation    Egress seg hdr fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SEG_HDR_FIFO_OFLOW_1_1 Egress seg hdr fifo overflow - 1,1

Explanation    Egress seg hdr fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_FIFO_OFLOW_0_0 Egress sgt fifo overflow - 0,0

Explanation    Egress sgt fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_FIFO_OFLOW_0_1 Egress sgt fifo overflow - 0,1

Explanation    Egress sgt fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_FIFO_OFLOW_1_0 Egress sgt fifo overflow - 1,0

Explanation    Egress sgt fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_FIFO_OFLOW_1_1 Egress sgt fifo overflow - 1,1

Explanation    Egress sgt fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_HDR_EXT_FIFO_OFLOW_0_0 Egress sgt hdr ext fifo overflow - 0,0

Explanation    Egress sgt hdr ext fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_HDR_EXT_FIFO_OFLOW_0_1 Egress sgt hdr ext fifo overflow - 0,1

Explanation    Egress sgt hdr ext fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_HDR_EXT_FIFO_OFLOW_1_0 Egress sgt hdr ext fifo overflow - 1,0

Explanation    Egress sgt hdr ext fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT_HDR_EXT_FIFO_OFLOW_1_1 Egress sgt hdr ext fifo overflow - 1,1

Explanation    Egress sgt hdr ext fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT2_FIFO_OFLOW_0_0 Egress sgt2 fifo overflow - 0,0

Explanation    Egress sgt2 fifo overflow on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT2_FIFO_OFLOW_0_1 Egress sgt2 fifo overflow - 0,1

Explanation    Egress sgt2 fifo overflow on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT2_FIFO_OFLOW_1_0 Egress sgt2 fifo overflow - 1,0

Explanation    Egress sgt2 fifo overflow on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SGT2_FIFO_OFLOW_1_1 Egress sgt2 fifo overflow - 1,1

Explanation    Egress sgt2 fifo overflow on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SP_NOT_ZERO_0_0 Non-zero seg profile detected - 0,0

Explanation    Non-zero seg profile detected on xaui-0 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SP_NOT_ZERO_0_1 Non-zero seg profile detected - 0,1

Explanation    Non-zero seg profile detected on xaui-0 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SP_NOT_ZERO_1_0 Non-zero seg profile detected - 1,0

Explanation    Non-zero seg profile detected on xaui-1 bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-EGR_SP_NOT_ZERO_1_1 Non-zero seg profile detected - 1,1

Explanation    Non-zero seg profile detected on xaui-1 bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MAXLEN_ERR_0 FIA to NPU-0 packet maximum length error - 0

Explanation    Packet maximum length error on FIA to NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MAXLEN_ERR_1 FIA to NPU-0 packet maximum length error - 1

Explanation    Packet maximum length error on FIA to NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MAXLEN_ERR_2 FIA to NPU-0 packet maximum length error - 2

Explanation    Packet maximum length error on FIA to NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MAXLEN_ERR_3 FIA to NPU-0 packet maximum length error - 3

Explanation    Packet maximum length error on FIA to NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_0 FIA to NPU-0 packet minimum length error - 0

Explanation    Packet minimum length error on FIA to NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_1 FIA to NPU-0 packet minimum length error - 1

Explanation    Packet minimum length error on FIA to NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_2 FIA to NPU-0 packet minimum length error - 2

Explanation    Packet minimum length error on FIA to NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_0_PKT_MINLEN_ERR_3 FIA to NPU-0 packet minimum length error - 3

Explanation    Packet minimum length error on FIA to NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_0 FIA to NPU-1 packet maximum length error - 0

Explanation    Packet maximum length error on FIA to NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_1 FIA to NPU-1 packet maximum length error - 1

Explanation    Packet maximum length error on FIA to NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_2 FIA to NPU-1 packet maximum length error - 2

Explanation    Packet maximum length error on FIA to NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MAXLEN_ERR_3 FIA to NPU-1 packet maximum length error - 3

Explanation    Packet maximum length error on FIA to NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_0 FIA to NPU-1 packet minimum length error - 0

Explanation    Packet minimum length error on FIA to NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_1 FIA to NPU-1 packet minimum length error - 1

Explanation    Packet minimum length error on FIA to NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_2 FIA to NPU-1 packet minimum length error - 2

Explanation    Packet minimum length error on FIA to NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-FIA2NPU_1_PKT_MINLEN_ERR_3 FIA to NPU-1 packet minimum length error - 3

Explanation    Packet minimum length error on FIA to NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_JUMP_ERR_0 GST jump error - 0

Explanation    GST jump error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_JUMP_ERR_1 GST jump error - 1

Explanation    GST jump error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_PWM_TIMEOUT_0 GST PWM timeout - 0

Explanation    GST PWM not received within 1 ms on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_PWM_TIMEOUT_1 GST PWM timeout - 1

Explanation    GST PWM not received within 1 ms on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_SYNC_ERR_0 GST SYNC ERR - 0

Explanation    GST Sync error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-GST_SYNC_ERR_1 GST SYNC ERR - 1

Explanation    GST Sync error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_INV_LEN_0 Ingress invalid length detected - 0

Explanation    Invalid ingress NPH length detected on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_INV_LEN_1 Ingress invalid length detected - 1

Explanation    Invalid ingress NPH length detected on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_L4_ARRAY_OFLOW_0 Ingress L4 array overflow - 0

Explanation    L4 array overflow on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_L4_ARRAY_OFLOW_1 Ingress L4 array overflow - 1

Explanation    L4 array overflow on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_L4_ARRAY_UFLOW_0 Ingress L4 array underflow - 0

Explanation    L4 array underflow on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-ING_L4_ARRAY_UFLOW_1 Ingress L4 array underflow - 1

Explanation    L4 array underflow on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_FIADDR_0 Missing EOP-0 from FIA DDR on bridge-0

Explanation    Missing EOP-0 from FIA DDR on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_FIADDR_1 Missing EOP-0 from FIA DDR on bridge-1

Explanation    Missing EOP-0 from FIA DDR on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_FIADDR_2 Missing EOP-0 from FIA DDR on bridge-2

Explanation    Missing EOP-0 from FIA DDR on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_FIADDR_3 Missing EOP-0 from FIA DDR on bridge-3

Explanation    Missing EOP-0 from FIA DDR on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_XAUI_0 Missing EOP-0 from XAUI on bridge-0

Explanation    Missing EOP-0 from XAUI on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_XAUI_1 Missing EOP-0 from XAUI on bridge-1

Explanation    Missing EOP-0 from XAUI on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_XAUI_2 Missing EOP-0 from XAUI on bridge-2

Explanation    Missing EOP-0 from XAUI on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_0_XAUI_3 Missing EOP-0 from XAUI on bridge-3

Explanation    Missing EOP-0 from XAUI on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_FIADDR_0 Missing EOP-1 from FIA DDR on bridge-0

Explanation    Missing EOP-1 from FIA DDR on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_FIADDR_1 Missing EOP-1 from FIA DDR on bridge-1

Explanation    Missing EOP-1 from FIA DDR on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_FIADDR_2 Missing EOP-1 from FIA DDR on bridge-2

Explanation    Missing EOP-1 from FIA DDR on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_FIADDR_3 Missing EOP-1 from FIA DDR on bridge-3

Explanation    Missing EOP-1 from FIA DDR on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_XAUI_0 Missing EOP-1 from XAUI on bridge-0

Explanation    Missing EOP-1 from XAUI on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_XAUI_1 Missing EOP-1 from XAUI on bridge-1

Explanation    Missing EOP-1 from XAUI on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_XAUI_2 Missing EOP-1 from XAUI on bridge-2

Explanation    Missing EOP-1 from XAUI on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-MISS_EOP_1_XAUI_3 Missing EOP-1 from XAUI on bridge-3

Explanation    Missing EOP-1 from XAUI on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_CONST_BP_0 NPU-0 constantly backpressuring bridge - 0

Explanation    NPU-0 is constantly backpressuring bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_CONST_BP_1 NPU-0 constantly backpressuring bridge - 1

Explanation    NPU-0 is constantly backpressuring bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_CONST_BP_2 NPU-0 constantly backpressuring bridge - 2

Explanation    NPU-0 is constantly backpressuring bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_CONST_BP_3 NPU-0 constantly backpressuring bridge - 3

Explanation    NPU-0 is constantly backpressuring bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MAXLEN_ERR_0 NPU-0 packet maximum length error - 0

Explanation    Packet maximum length error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MAXLEN_ERR_1 NPU-0 packet maximum length error - 1

Explanation    Packet maximum length error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MAXLEN_ERR_2 NPU-0 packet maximum length error - 2

Explanation    Packet maximum length error on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MAXLEN_ERR_3 NPU-0 packet maximum length error - 3

Explanation    Packet maximum length error on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MINLEN_ERR_0 NPU-0 packet minimum length error - 0

Explanation    Packet minimum length error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MINLEN_ERR_1 NPU-0 packet minimum length error - 1

Explanation    Packet minimum length error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MINLEN_ERR_2 NPU-0 packet minimum length error - 2

Explanation    Packet minimum length error on NPU-0 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_PKT_MINLEN_ERR_3 NPU-0 packet minimum length error - 3

Explanation    Packet minimum length error on NPU-0 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_SCH_0_HANG_0 NPU-0 scheduler 0 hang - 0

Explanation    Scheduler 0 Hang on NPU-0 interface on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_CORE_ERR_0 NPU-0 timestamp core error on bridge - 0

Explanation    NPU-0 timestamp core error on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_CORE_ERR_1 NPU-0 timestamp core error on bridge - 1

Explanation    NPU-0 timestamp core error on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_CORE_ERR_2 NPU-0 timestamp core error on bridge - 2

Explanation    NPU-0 timestamp core error on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_CORE_ERR_3 NPU-0 timestamp core error on bridge - 3

Explanation    NPU-0 timestamp core error on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_UPDATE_ERR_0 NPU-0 timestamp update error - 0

Explanation    Timestamp update error on NPU-0 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_0_TS_UPDATE_ERR_1 NPU-0 timestamp update error - 1

Explanation    Timestamp update error on NPU-0 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_CONST_BP_0 NPU-1 constantly backpressuring bridge - 0

Explanation    NPU-1 is constantly backpressuring bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_CONST_BP_1 NPU-1 constantly backpressuring bridge - 1

Explanation    NPU-1 is constantly backpressuring bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_CONST_BP_2 NPU-1 constantly backpressuring bridge - 2

Explanation    NPU-1 is constantly backpressuring bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_CONST_BP_3 NPU-1 constantly backpressuring bridge - 3

Explanation    NPU-1 is constantly backpressuring bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MAXLEN_ERR_0 NPU-1 packet maximum length error - 0

Explanation    Packet maximum length error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MAXLEN_ERR_1 NPU-1 packet maximum length error - 1

Explanation    Packet maximum length error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MAXLEN_ERR_2 NPU-1 packet maximum length error - 2

Explanation    Packet maximum length error on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MAXLEN_ERR_3 NPU-1 packet maximum length error - 3

Explanation    Packet maximum length error on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MINLEN_ERR_0 NPU-1 packet minimum length error - 0

Explanation    Packet minimum length error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MINLEN_ERR_1 NPU-1 packet minimum length error - 1

Explanation    Packet minimum length error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MINLEN_ERR_2 NPU-1 packet minimum length error - 2

Explanation    Packet minimum length error on NPU-1 interface on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_PKT_MINLEN_ERR_3 NPU-1 packet minimum length error - 3

Explanation    Packet minimum length error on NPU-1 interface on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_CORE_ERR_0 NPU-1 timestamp core error on bridge - 0

Explanation    NPU-1 timestamp core error on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_CORE_ERR_1 NPU-1 timestamp core error on bridge - 1

Explanation    NPU-1 timestamp core error on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_CORE_ERR_2 NPU-1 timestamp core error on bridge - 2

Explanation    NPU-1 timestamp core error on bridge instance-2.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_CORE_ERR_3 NPU-1 timestamp core error on bridge - 3

Explanation    NPU-1 timestamp core error on bridge instance-3.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_UPDATE_ERR_0 NPU-1 timestamp update error - 0

Explanation    Timestamp update error on NPU-1 interface on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-NPU_1_TS_UPDATE_ERR_1 NPU-1 timestamp update error - 1

Explanation    Timestamp update error on NPU-1 interface on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PAR_MERR_0 Multi bit mem parity error - 0

Explanation    Multi bit mem parity error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PAR_MERR_1 Multi bit mem parity error - 1

Explanation    Multi bit mem parity error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PAR_SERR_0 Single bit mem parity error - 0

Explanation    Single bit mem parity error on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PAR_SERR_1 Single bit mem parity error - 1

Explanation    Single bit mem parity error on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_FIA_0 Packet length error from FIA for NPU-0 on bridge-0

Explanation    Packet length error from FIA for NPU-0 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_FIA_1 Packet length error from FIA for NPU-0 on bridge-1

Explanation    Packet length error from FIA for NPU-0 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_FIA_2 Packet length error from FIA for NPU-0 on bridge-2

Explanation    Packet length error from FIA for NPU-0 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_FIA_3 Packet length error from FIA for NPU-0 on bridge-3

Explanation    Packet length error from FIA for NPU-0 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_XAUI_0 Packet length error - 0 from XAUI on bridge-0

Explanation    Packet length error - 0 from XAUI on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_XAUI_1 Packet length error - 0 from XAUI on bridge-1

Explanation    Packet length error - 0 from XAUI on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_XAUI_2 Packet length error - 0 from XAUI on bridge-2

Explanation    Packet length error - 0 from XAUI on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_0_XAUI_3 Packet length error - 0 from XAUI on bridge-3

Explanation    Packet length error - 0 from XAUI on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_FIA_0 Packet length error from FIA for NPU-1 on bridge-0

Explanation    Packet length error from FIA for NPU-1 on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_FIA_1 Packet length error from FIA for NPU-1 on bridge-1

Explanation    Packet length error from FIA for NPU-1 on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_FIA_2 Packet length error from FIA for NPU-1 on bridge-2

Explanation    Packet length error from FIA for NPU-1 on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_FIA_3 Packet length error - 1 from FIA on bridge-3

Explanation    Packet length error from FIA for NPU-1 on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_XAUI_0 Packet length error - 1 from XAUI on bridge-0

Explanation    Packet length error - 1 from XAUI on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_XAUI_1 Packet length error - 1 from XAUI on bridge-1

Explanation    Packet length error - 1 from XAUI on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_XAUI_2 Packet length error - 1 from XAUI on bridge-2

Explanation    Packet length error - 1 from XAUI on bridge instance-2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-PKT_LEN_ERR_1_XAUI_3 Packet length error - 1 from XAUI on bridge-3

Explanation    Packet length error - 1 from XAUI on bridge instance-3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-SCH_0_HANG_0 Scheduler 0 hang - 0

Explanation    Scheduler 0 Hang on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-SCH_0_HANG_1 NPU-0 scheduler 0 hang - 1

Explanation    Scheduler 0 Hang on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-SCH_1_HANG_0 Scheduler 1 hang - 0

Explanation    Scheduler 1 Hang on bridge instance-0.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-SCH_1_HANG_1 Scheduler 1 hang - 1

Explanation    Scheduler 1 Hang on bridge instance-1.

Recommended Action    Please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_FRAG_ERR_0 XAUI to NPU-0 fragment error - 0

Explanation    XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_FRAG_ERR_1 XAUI to NPU-0 fragment error - 1

Explanation    XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_FRAG_ERR_2 XAUI to NPU-0 fragment error - 2

Explanation    XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_FRAG_ERR_3 XAUI to NPU-0 fragment error - 3

Explanation    XAUI interface to NPU-0 reported fragmentation error on TX side on bridge instance - 3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_FULL_0 XAUI 0 High Queue full error - 0

Explanation    Queue full error on XAUI 0 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_FULL_1 XAUI 0 High Queue full error - 1

Explanation    Queue full error on XAUI 0 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_OFLOW_0 XAUI 0 High Queue overflow error - 0

Explanation    Queue overflow error on XAUI 0 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_OFLOW_1 XAUI 0 High Queue overflow error - 1

Explanation    Queue overflow error on XAUI 0 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_PKT_LEN_0 XAUI 0 High Queue packet length error - 0

Explanation    Queue packet length error on XAUI 0 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_PKT_LEN_1 XAUI 0 High Queue packet length error - 1

Explanation    Queue packet length error on XAUI 0 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_SEQ_0 XAUI 0 High Queue sequence error - 0

Explanation    Queue sequence error on XAUI 0 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_HQ_SEQ_1 XAUI 0 High Queue sequence error - 1

Explanation    Queue sequence error on XAUI 0 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_FULL_0 XAUI 0 Low Queue full error - 0

Explanation    Queue full error on XAUI 0 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_FULL_1 XAUI 0 Low Queue full error - 1

Explanation    Queue full error on XAUI 0 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_OFLOW_0 XAUI 0 Low Queue overflow error - 0

Explanation    Queue overflow error on XAUI 0 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_OFLOW_1 XAUI 0 Low Queue overflow error - 1

Explanation    Queue overflow error on XAUI 0 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_PKT_LEN_0 XAUI 0 Low Queue packet length error - 0

Explanation    Queue packet length error on XAUI 0 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_PKT_LEN_1 XAUI 0 Low Queue packet length error - 1

Explanation    Queue packet length error on XAUI 0 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_SEQ_0 XAUI 0 Low Queue sequence error - 0

Explanation    Queue sequence error on XAUI 0 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_LQ_SEQ_1 XAUI 0 Low Queue sequence error - 1

Explanation    Queue sequence error on XAUI 0 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_FULL_0 XAUI 0 Mgmt Queue full error - 0

Explanation    Queue full error on XAUI 0 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_FULL_1 XAUI 0 Mgmt Queue full error - 1

Explanation    Queue full error on XAUI 0 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_OFLOW_0 XAUI 0 Mgmt Queue overflow error - 0

Explanation    Queue overflow error on XAUI 0 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_OFLOW_1 XAUI 0 Mgmt Queue overflow error - 1

Explanation    Queue overflow error on XAUI 0 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_PKT_LEN_0 XAUI 0 Mgmt Queue packet length error - 0

Explanation    Queue packet length error on XAUI 0 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_PKT_LEN_1 XAUI 0 Mgmt Queue packet length error - 1

Explanation    Queue packet length error on XAUI 0 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_SEQ_0 XAUI 0 Mgmt Queue sequence error - 0

Explanation    Queue sequence error on XAUI 0 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_0_MQ_SEQ_1 XAUI 0 Mgmt Queue sequence error - 1

Explanation    Queue sequence error on XAUI 0 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_FRAG_ERR_0 XAUI to NPU-1 fragment error - 0

Explanation    XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_FRAG_ERR_1 XAUI to NPU-1 fragment error - 1

Explanation    XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_FRAG_ERR_2 XAUI to NPU-1 fragment error - 2

Explanation    XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 2.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_FRAG_ERR_3 XAUI to NPU-1 fragment error - 3

Explanation    XAUI interface to NPU-1 reported fragmentation error on TX side on bridge instance - 3.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_FULL_0 XAUI 1 High Queue full error - 0

Explanation    Queue full error on XAUI 1 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_FULL_1 XAUI 1 High Queue full error - 1

Explanation    Queue full error on XAUI 1 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_OFLOW_0 XAUI 1 High Queue overflow error - 0

Explanation    Queue overflow error on XAUI 1 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_OFLOW_1 XAUI 1 High Queue overflow error - 1

Explanation    Queue overflow error on XAUI 1 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_PKT_LEN_0 XAUI 1 High Queue packet length error - 0

Explanation    Queue packet length error on XAUI 1 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_PKT_LEN_1 XAUI 1 High Queue packet length error - 1

Explanation    Queue packet length error on XAUI 1 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_SEQ_0 XAUI 1 High Queue sequence error - 0

Explanation    Queue sequence error on XAUI 1 HQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_HQ_SEQ_1 XAUI 1 High Queue sequence error - 1

Explanation    Queue sequence error on XAUI 1 HQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_FULL_0 XAUI 1 Low Queue full error - 0

Explanation    Queue full error on XAUI 1 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_FULL_1 XAUI 1 Low Queue full error - 1

Explanation    Queue full error on XAUI 1 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_OFLOW_0 XAUI 1 Low Queue overflow error - 0

Explanation    Queue overflow error on XAUI 1 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_OFLOW_1 XAUI 1 Low Queue overflow error - 1

Explanation    Queue overflow error on XAUI 1 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_PKT_LEN_0 XAUI 1 Low Queue packet length error - 0

Explanation    Queue packet length error on XAUI 1 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_PKT_LEN_1 XAUI 1 Low Queue packet length error - 1

Explanation    Queue packet length error on XAUI 1 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_SEQ_0 XAUI 1 Low Queue sequence error - 0

Explanation    Queue sequence error on XAUI 1 LQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_LQ_SEQ_1 XAUI 1 Low Queue sequence error - 1

Explanation    Queue sequence error on XAUI 1 LQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_FULL_0 XAUI 1 Mgmt Queue full error - 0

Explanation    Queue full error on XAUI 1 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_FULL_1 XAUI 1 Mgmt Queue full error - 1

Explanation    Queue full error on XAUI 1 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_OFLOW_0 XAUI 1 Mgmt Queue overflow error - 0

Explanation    Queue overflow error on XAUI 1 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_OFLOW_1 XAUI 1 Mgmt Queue overflow error - 1

Explanation    Queue overflow error on XAUI 1 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_PKT_LEN_0 XAUI 1 Mgmt Queue packet length error - 0

Explanation    Queue packet length error on XAUI 1 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_PKT_LEN_1 XAUI 1 Mgmt Queue packet length error - 1

Explanation    Queue packet length error on XAUI 1 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_SEQ_0 XAUI 1 Mgmt Queue sequence error - 0

Explanation    Queue sequence error on XAUI 1 MQ on bridge instance-0.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-BRIDGE-3-XAUI_1_MQ_SEQ_1 XAUI 1 Mgmt Queue sequence error - 1

Explanation    Queue sequence error on XAUI 1 MQ on bridge instance-1.

Recommended Action    If the error persists, please reload the board using the command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CAIBIST Messages

Error Message     
 
    
    
   

%PLATFORM-CAIBIST-3-ERR_HW_BIST [chars] asic instance [dec] bist block [chars] ch [dec] failed on BIST[[hex]].

Explanation    BIST failure

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CAIBIST-3-ERR_HW_BIST_INFO [chars]

Explanation    provide BIST failure info

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CAIBIST-3-ERR_HW_BIST_TIMEDOUT [chars] asic instance [dec] bist block [chars] BIST timedout.

Explanation    BIST failure

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CAIBIST-3-ERR_SW_INIT [chars].

Explanation    software initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CANB_SERVER Messages

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-ALARM_CLEARED Clear alarm from CBC in slot [chars], alarm code [chars]

Explanation    Alarm cleared received from CBC, condition has alleviated.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-ALARM_INDICATION Raise alarm from CBC in slot [chars], alarm code [chars]

Explanation    Alarm indication received from CBC. This may be a serious failure (example: power sequencer failure), however process may continue functioning as expected (or successfully retry) despite the failure.

Recommended Action    Provide the following CLI: (admin)# show env Use the pid from canb-server output to look for matching pid in the pfm output. If the alarm indication does not clear within 30 minutes, contact TAC.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-ERROR_EXIT Canbus-server process exiting in [chars].[dec], error code [chars]

Explanation    The CAN Bus Server process exited due to the reason mentioned in the message.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Verify process is up and running, give CLI: If it is still non-operational, use CLI: If it is still non-operational, perform card reload. If still non-operational, contacting TAC and performing RSP switchover is recommended.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-IDPROM_CACHE_OVERFLOW IDPROM cache write overflow detected at [chars].[dec] on tx_request_array[[dec]].tx_base_ptr, a retry will be scheduled

Explanation    This is an error message related to the Canbus Controller processing the received UART message.

Recommended Action    Do EP soft/hard OIR, or restart canb-server.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-INVALID_SLOT Invalid slot id:[dec] detected at [chars].[dec]

Explanation    This is an error message related to the Canbus Controller processing the received message.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-INVALID_SLOT_BUS Invalid slot id:[dec] on bus:[dec] detected at [chars].[dec]

Explanation    This is an error message related to the Canbus Controller processing the received message.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-MEM_CORRUPT_TX_REQUEST_ARRAY Memory corruption detected at [chars].[dec] on tx_request_array[[dec]], magic_num expected: [hex], actual [hex]

Explanation    This is an error message related to the Canbus Controller processing the received UART message.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-MESSAGE_FAILED Unexpected CBC message received from slot [chars] [ver [dec].[dec]] for msg type [dec], id [dec], len [dec]

Explanation    A message was received and did not match any outstanding requests and also is not a standalone message. This is not a critical failure, the process can continue functioning as expected despite the message arrival, message is discarded.

Recommended Action    If this appears once or infrequently, it is not necessary to contact TAC. If it appears continuously or comes and goes repeatedly, it is best to please collect the following details and contact TAC. Provide the following CLI output: (admin)# show canb server-stats loc all (admin)# show canb trace loc target nodeid (admin)# debug canb server error loc target nodeid Let the debug run 2 minutes (admin)# undebug canb server error loc target nodeid (admin)# show canb trace loc target nodeid (admin)# show canb server-stats loc all

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-OBFL_CACHE_OVERFLOW OBFL cache write overflow detected at [chars].[dec] on tx_request_array[[dec]].tx_base_ptr, a retry will be scheduled

Explanation    This is an error message related to the Canbus Controller processing the received UART message.

Recommended Action    restart canb-server.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-3-OPERATION_FAIL Failed in [chars].[dec], error code [chars]

Explanation    The particular operation mentioned in the message failed due to some reason. This may be a serious failure, however process may continue functioning as expected (or successfully retry) despite the failure.

Recommended Action    Provide the following debug: (admin)# show canb server-stats loc all (admin)# show canb trace loc target nodeid (admin)# debug canb server error loc target nodeid Let the debug run for 2 minutes (admin)# undebug canb server error loc target nodeid (admin)# show canb server-stats loc all

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-CRC_ERROR CRC error in Rx message from CBC and recover by retransmit, throttled count equals [dec]

Explanation    The message received from Canbus Controller has CRC error computed. This is indicative of a low level serial device transmission error. In most cases, the message is fully recoverable automatically.

Recommended Action    Provide the following CLI output: (admin)# show canb trace loc target nodeid (admin)# show canb server-stats loc all (admin)# show env volt Wait 5 minutes, again give CLI: (admin)# show env volt If the voltage output looks correct, then there is likely no negative impact from the CRC error. If the voltage output looks incorrect, wait 30 minutes and give the CLI command again. If the voltage output still looks incorrect, If this error occurs repetitively for a particular card, contact TAC for further evaluation.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-OPERATION_INFO [chars].[dec], Info - [chars]

Explanation    Informational condition and/or failure. The process can continue functioning as expected despite the failure.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-RP_ISOLATION [chars] is in RP isolation

Explanation    This is an informational message indicating that target RP has transitioned into RP isolation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-RP_ISOLATION_RESET_REQ CPU reset request ignored for [chars]

Explanation    This is an informational message indicating that RP Isolation is in force, CPU reset request for the target slot is ignored.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-UPGRADE_COMPLETED CBC upgrade completed on [chars]

Explanation    This is an informational message indicating that Canbus Controller firmware upgrade is completed on the specified location.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-UPGRADE_IN_PROGRESS CBC upgrade in progress on [chars], Page [dec] of range [dec]-[dec]

Explanation    This is an informational message indicating that Canbus Controller firmware upgrade is in progress on the specified location. The page that is being presently upgraded is mentioned in the message. This page number would be in the specified range, corresponding to the Canbus Controller partition that is being upgraded.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-UPGRADE_INFO CBC upgrade on [chars]: [chars]

Explanation    This is an informational message related to the Canbus Controller upgrade process on the specified location.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-6-UPGRADE_STARTED Starting CBC upgrade on [chars] with image [chars]

Explanation    This is an informational message indicating that the Canbus Controller firmware on the specified loation is going to be upgraded with the image at the specified path.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-7-CBC_POST_RESET_NOTIFICATION Node [chars], [chars] ([hex][hex]%02x[hex])

Explanation    Informational log only

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION Node [chars], [chars] ([hex][hex]%02x[hex])

Explanation    Informational log only

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CANB_SERVER-7-OPERATION_DEBUG Debug [chars].[dec], [dec], [dec], error code [chars]

Explanation    This is a programmed diagnostic debug message.

Recommended Action    No action required.

CARD Messages

Error Message     
 
    
    
   

%PLATFORM-CARD-0-OVERCURRENT ClkCtrl detected an overcurrent condition on card [chars]

Explanation    ClkCtrl driver detected a card overcurrent condition

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CARDMGR Messages

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-BAD_CS_INFO could not get CS revision info!

Explanation    Could not get CS revision info

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-CHDIR_FAILED chdir to [chars] failed: [chars]

Explanation    Chdir failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-MODULE_UNAVAILABLE module [chars] not available

Explanation    Module unavailable

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-NO_CARDS_DEFINED no cards defined

Explanation    No cards defined

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-NO_DRIVERS_FOUND no device drivers defined

Explanation    No device drivers

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-NO_SOCKETS no sockets found!

Explanation    No sockets

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-PCMCIA_INIT_ERROR PCMCIA initialization error at: [chars]

Explanation    PCMCIA initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-SELECT_FAILURE select (): [chars]

Explanation    Select failure

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-3-UNSUPPORTED_CARD Unsupported card in socket [dec]

Explanation    Unsupported card

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-6-PRODUCT_INFO product info: [chars]

Explanation    Product info

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-6-SOCKET_INFO socket [dec]: [chars]

Explanation    Socket info

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-ADJ_RES_FAILED could not adjust resource: [chars]: [chars]

Explanation    Could not adjust resource

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-BAD_OPEN could not open [chars]: [chars]

Explanation    Open of file failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-BIND_FAILED bind '[chars]' to socket [dec] failed: [chars]

Explanation    Bind failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-BIND_MTD_REGION_FAILED bind MTD '[chars]' to region at [hex] failed: [chars]

Explanation    Bind mtd region failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-BIND_MTD_SOCKET_FAILED bind MTD '[chars]' to socket [dec] failed: [chars]

Explanation    Bind mtd to socket failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-CIS_DATA_PARSING_ERROR error parsing CIS([hex]) on socket [dec]: [chars]

Explanation    CIS data parsing error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-CIS_DATA_READ_ERROR error reading CIS data on socket [dec]: [chars]

Explanation    CIS data read error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-CIS_REPLACE_ERROR could not replace CIS: [chars]

Explanation    CIS replace error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-CS_REL_MISMATCH Card Services release does not match

Explanation    Release mismatch

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-GET_DEV_INFO_FAILED get device info on socket [dec] failed: [chars]

Explanation    Device info failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-NO_MEM Malloc failure

Explanation    Out of memory

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-OPEN_SOCK_FAILED open_sock(socket [dec]) failed: [chars]

Explanation    Open of socket failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-READ_FAILED read ([dec]): [chars]

Explanation    Read failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-THREAD_CREATE_FAILED Thread create failed: [chars]

Explanation    Thread create failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-UNBIND_FAILED unbind '[chars]' from socket [dec] failed: [chars]

Explanation    Unbind failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CARDMGR-7-UNBIND_MTD_FAILED unbind MTD '[chars]' from socket [dec] failed: [chars]

Explanation    Unbind MTD failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CBC Messages

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_A_FAILED CBC A failed

Explanation    CBC detected CANBUS A failure. This may be a serious failure, however the system may continue functioning as expected despite the failure.

Recommended Action    Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_B_FAILED CBC B failed

Explanation    CBC detected CANBUS B failure. This may be a serious failure, however the system may continue functioning as expected despite the failure.

Recommended Action    Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_BOTH_FAILED Canbus A and B have failed

Explanation    CBC detected both CANBUS A and CANBUS B have failed. This may be a serious hardware failure.

Recommended Action    Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_FANTRAY_INRUSH_FAILED CBC inrush fantray has failed

Explanation    CBC has detected that the inrush fantray has failed. This will result in the LCs getting overheated. Please turn off power to the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_PWR_FUSE_FAILED CBC power fuse has failed

Explanation    CBC has detected power fuse failure. The proper functioning of the board requies that the current drawn be within the rating of the boards power fuse.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-CANBUS_PWR_SEQ_FAILED CBC power sequence failed

Explanation    The CBC alarm indicating that the power up sequence has failed. The proper functioning of the board requires that a successful application of power be applied to the board in the proper sequence.

Recommended Action    Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-SLOT_ID_CHANGE CBC slot id changed

Explanation    CBC detected unexpected slot id change. The system can no longer manage/monitor the card's environment conditions.

Recommended Action    Reboot the LC. If the problem persists Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CBC-1-VERSION_ERROR CBC major version error on node [chars]. Expected equals [dec], Actual equals [dec]

Explanation    The CBC on the slot has an incorrect firmware type programmed. The firmware major version does not match the card type.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CCI_HAL_SATORI Messages

Error Message     
 
    
    
   

%PLATFORM-CCI_HAL_SATORI-3-ERR_TX_PKT [chars]: [dec] [chars]

Explanation    CCI HAL SATORI Packet transmit error.

Recommended Action    Execute spp_pdma_show_ltrace from the kshell of the card where this message was seen.

CCI_SSTAR Messages

Error Message     
 
    
    
   

%PLATFORM-CCI_SSTAR-3-ERR_DRV_INIT CPUCtrl (SSTAR) Initialization failed: [chars]

Explanation    The cpuctrl (sstar) driver detected an error during initialization.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CCI_SSTAR-3-ERR_EVM_CREATE Failed to create event manager

Explanation    The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CCI_SSTAR-3-ERR_INTERRUPT_THREAD_EXIT [chars] priority interrupt thread failed. Exiting.

Explanation    The cpuctrl (sstar) driver detected a critical failure in the interrupt thread initialization. Abort and exit the thread.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CCTL_ENS Messages

Error Message     
 
    
    
   

%PLATFORM-CCTL_ENS-3-ERROR_EXIT Envmon process exiting because [chars], error code [chars]

Explanation    The Chassis Control driver process exited due to the reason mentioned in the message.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location ' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CCTL_ENS-7-OPERATION_FAIL Failed to [chars], error code [chars]

Explanation    The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.

Recommended Action    Debug message only. No action is required.

CCTL Messages

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-CARD_POWERUP_FAIL Unable to powerup card(for node:[chars]) rc: [chars]

Explanation    The hardware powerup was unsuccessful due to the mentioned reason.

Recommended Action    Card powerup is typically initiated when a card needs to power. If that fails, please collect 'show cctl trace shelfmgr loc ' from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-CARD_SHUTDOWN_FAIL Unable to shutdown card(for node: [chars]) rc: [chars]

Explanation    The shutdown of the card was unsuccessful due to the mentioned reason.

Recommended Action    Card shutdown is typically initiated when a card needs to be hard reset. If that fails, only a software reset be initiated. Please collect 'show cctl trace shelfmgr loc' from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-CHASSIS_SHUTDOWN_FAIL Unable to shutdown chassis because [chars]

Explanation    The shutdown of the chassis was unsuccessful due to the mentioned reason.

Recommended Action    Chassis shutdown is typically initiated due to some critical failure. If the software initiated chassis shutdown has failed, then user should intervene and shut down the chassis manually.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-CPLD_POWER_ALARM Fabric PLD [chars] interrupt detected instance [dec] Channel [dec] [chars] register: [hex]

Explanation    The Fabric PLD power fault alarm was encountered

Recommended Action    A power fault has occurred.If the fault has occurred, node will be shutdown. Please collect syslog and cctl client debug's from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-CPLD_POWER_CTRL_ALARM Fabric PLD [chars] interrupt detected instance [dec] [chars] register [hex]

Explanation    The Fabric PLD power fault alarm was encountered

Recommended Action    A power fault has occurred.If the fault has occurred, node will be shutdown. Please collect syslog and cctl client debug's from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-MB_POWERUP_CHECK_FAIL Voltage validation failed, motherboard did not power up. Shutting down card.

Explanation    The voltage validation and power status check for the card failed. This might be a power issue to the card or a faulty card.

Recommended Action    Try reloading the card or physical OIR, verify power to chassis and the card.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-RESET_SP_FAIL Unable to reset SP node([chars]) rc: [chars]

Explanation    The hard reset of sp was unsuccessful due to the mentioned reason.

Recommended Action    Reset of SP is typically initiated when that SP needs to be hard reset. If that fails, only a software reset be initiated. Please collect 'show cctl trace shelfmgr loc' from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-STANDBY_SHUTDOWN_FAILED Unable to shutdown the standby node as part of chassis shutdown

Explanation    The shutdown of the standby SC/RP node failed during the chassis shutdown process.

Recommended Action    Please power off the chassis manually.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-TAIKO_POWER_ALARM [chars] Alarm detected on Taiko node([dec]) register: [hex]

Explanation    The taiko power alarm was encountered

Recommended Action    Node will be shutdown immediately as hardware error occured. Please collect 'show cctl trace error' from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-2-TAIKO_TEMP_ALARM [chars] Alarm detected on Taiko node([dec]) register: [hex]

Explanation    The taiko temperature alarm was encountered

Recommended Action    Node will be shutdown immediately as hardware error occured. Please collect 'show cctl trace error' from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-BARBARIAN_VOLT_FIX_FAILED Voltage fix on VP4 could not be activated for Barbarian SPA in slot [dec]

Explanation    VP4 rail on the SPA could not be margined to nominal voltage due to some failure.

Recommended Action    SAR chip SRAM parity errors might result. Margin the rail manually.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-ERROR_EXIT Envmon process exiting because [chars], error code [chars]

Explanation    The Chassis Control driver process exited due to the reason mentioned in the message.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process envmon location ' to verify that the process is up and running. If it is still non-operational, try doing from the admin mode 'process restart envmon location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_CLEAR_LED An I2C failure occurred while trying to clear the alarm LED(s).

Explanation    An I2C failure occurred while trying to clear one or more of the alarm card LEDs.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_HANG Unable to recover from I2C bus hang for sensor [chars].

Explanation    An I2C bus hang was encountered when attempting to access a sensor.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_PM_CLEAR_FAULT An I2C failure occurred while trying to clear the fault status of Power Module id: [dec].

Explanation    An I2C error was encountered when attempting to clear the fault / alarm information of a Power Module.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_PM_FAULT An I2C failure occurred while checking the fault status of Power Module id: [dec].

Explanation    An I2C error was encountered when attempting to access the fault / alarm information of a Power Module.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_PM_LED An I2C failure occurred while trying to set the Power Module presence LED(s).

Explanation    An I2C failure occurred while trying to set or clear the LEDs of a Power Module in a power shelf.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_PM_PRESENCE An I2C failure occurred while checking for the presence of Power Modules in [chars].

Explanation    This I2C failure indicates that there was a fault when checking the presence information for the Power Modules in a power shelf. The shelf might have been removed or is not inserted correctly.

Recommended Action    Check that the shelf is present and seated correctly.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_PM_SENSOR An I2C failure occurred when reading sensor [chars] for Power Module id: [dec].

Explanation    An I2C error was encountered when attempting to read a sensor on a Power Module.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_SET_LED An I2C failure occurred while trying to set the alarm LED(s).

Explanation    An I2C failure occurred while trying to set one or more of the alarm card LEDs.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-I2C_FAILURE_ZONE An I2C failure occurred while checking the zone breaker status in [chars].

Explanation    This I2C failure indicates that a fault occurred when checking the circuit breaker status on the shelf.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-MASTERSHIP_EXIT Exiting because not able to [chars] mastership

Explanation    The Chassis Control driver process exited as it was not able to grab mastership or unable to release it.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-READ_POWER_SHELF_TYPE_FAILURE Unable to detect power shelf type. Assuming AC shelf and continuing for now. Please check EEPROM programming on power shelf backplane.

Explanation    We are unable to read the power shelf backplane EEPROM for some reason. Need to check the programming of the backplane.

Recommended Action    Check that the power-shelf is seated correctly, and that the backplane EEPROM is programmed correctly. In the admin mode, use 'show diag power-supply eeprom-info' to check the contents of the EEPROM.

Error Message     
 
    
    
   

%PLATFORM-CCTL-3-UNKNOWN_CHASSIS_ID Unknown Controller/Platform type [hex] read from EEPROM.

Explanation    The value read from the EEPROM does not match any of the known Controller/platform type values.

Recommended Action    Please check the EEPROM programming. 'show diag eeprom-info' in admin mode gives a raw dump of the EEPROM data. Refer EDCS-137763 to interpret the data to check if the Controller/Platform type is programmed correctly or not. If the Controller/Platform type is incorrect, the unit will have to be RMA'd to reprogram the EEPROM correctly. If the Controller/Platform type is correct, EEPROM read is failed due to unknown reason, Its Recommended to Hard OIR of the card.

Error Message     
 
    
    
   

%PLATFORM-CCTL-4-BARBARIAN_VOLT_FIX_ACTIVE Voltage fix on VP4 active for Barbarian SPA in slot [dec]

Explanation    VP4 rail on the SPA is margined to nominal voltage due to SAR chip errata.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-4-CPLD_POWER_SEQUENCER_FAULT_OR_ALERT Power Sequencer [inst: [dec] channel: [dec] sensor_type: [chars]] detected alarm [chars] value: [dec] threshold: [dec]

Explanation    The fabric power sequencer detected a temperature or power alarm.

Recommended Action    An alarm was detected. If a critical alarm is detected node will be shutdown. Please collect syslog and cctl client debugs from the node where alarm was detected.

Error Message     
 
    
    
   

%PLATFORM-CCTL-4-CPLD_POWER_WARN Fabric PLD [chars] interrupt detected instance [dec] Channel [dec] [chars] register: [hex]

Explanation    The Fabric PLD power alert was encountered

Recommended Action    A power alert has occurred. If the alert has occurred, node will not be shutdown. Please collect syslog and cctl client debug's from the node on which this ios-msg is seen.

Error Message     
 
    
    
   

%PLATFORM-CCTL-4-UNKNOWN_SHELF_ID Unknown shelf ID [hex] read from power shelf backplane EEPROM - please check EEPROM programming.

Explanation    The value read from the power shelf backplane does not match any of the known shelf ID values. Please check the EEPROM programming.

Recommended Action    Please check the EEPROM programming of the power-shelf backplane. 'show diag power-supply eeprom-info' in admin mode gives a raw dump of the EEPROM data. Refer EDCS-137763 to interpret the data to check if the shelf ID is programmed correctly or not. If the shelf ID is incorrect, the unit will have to be RMA'd to reprogram the EEPROM correctly.

Error Message     
 
    
    
   

%PLATFORM-CCTL-6-OPERATION_SUCCESS [chars]

Explanation    The particular operation mentioned in the message succeeded.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-6-TEMP_ALARM [chars] alarm occured for [chars] sensor at temperature [dec] deg C, against configured threshold of [dec] deg C

Explanation    Informational msg indicating temperature at which alarm occured.

Recommended Action    Software will take corrective action on its own. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-6-TEMP_READ_ERR Invalid temp value read for [chars] sensor.

Explanation    Informational msg indicating invalid temperature read

Recommended Action    Software will take corrective action on its own. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CCTL-7-OPERATION_FAIL Failed to [chars], error code [chars]

Explanation    The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.

Recommended Action    Debug message only. No action is required.

CE_SWITCH Messages

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-2-DEADLINE_MONITOR_FAILED Switch process failed to register with deadline monitor, error [chars]

Explanation    ce-switch process failed to register with deadline monitor

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-2-LINK_SHUT_DOWN Intra-rack switch port [dec] state changed to ADMIN_DOWN

Explanation    The intra-rack switch port was administratively shut down.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-2-STACKING_LINK_DOWN Broadcom switch stacking link down

Explanation    The driver was unable to successfully initialise the stacking link

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-3-DMAC_LINK_STATE_CHANGE CE_SWITCH DMAC link interface ([dec]) is down

Explanation    The internal link interface for the specified port is down.

Recommended Action    The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c CE_SWITCH .pcds file. pcds_decode -c NIANTIC .pcds file. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of (admin)'show tech support control ethernet location nodeId'

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-6-BADSFP Front panel nV Edge Control Port [dec] has unsupported SFP plugged in.
Port is disabled, please plug in Cisco support 1Gig SFP for port to be enabled

Explanation    nV Edge Control ports needs Cisco supported SFPs.

Recommended Action    'Plug in a Cisco supported 1Gig SFP'

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-6-ERRDIS
Front Panel port [dec] error disabled because of UDLD
uni directional forwarding. There will be automatic
retries to try and bring up the port periodically

Explanation    Front panel SFP port is UDLD Uni-Directional, check sfp/fiber for errors

Recommended Action    'Check if the media (fiber / sfp) has any errors'

Error Message     
 
    
    
   

%PLATFORM-CE_SWITCH-6-UPDN Interface [dec] ([chars]) is [chars]

Explanation    A link to the RSP control plane switch has change state.

Recommended Action    'Copy the error message exactly as it appears on the console or in the system log. Issue the show controllers ce-switch link detail location loc in msg command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show controllers ce-switch link detail location loc in msg output, call your Cisco technical support representative and provide the representative with the gathered information.'

CEMGBL Messages

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-2-CRIT [chars] : [chars]

Explanation    An unexpected critical error condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-2-CRIT [chars] : [chars]

Explanation    An unexpected critical error condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-2-SFP_INVALID_TYPE CE SFP monitor init failed with invalid board type [hex]

Explanation    An unexpected failure in register notification failed.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-2-SFP_INVALID_TYPE CE SFP monitor init failed with invalid board type [hex]

Explanation    An unexpected failure in register notification failed.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-4-WARNING [chars] : [chars]

Explanation    An unexpected condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-4-WARNING [chars] : [chars]

Explanation    An unexpected condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-5-SFP_OIR Control-ethernet external gigabit sfp [chars] - [chars]

Explanation    The control-eth ext ge sfp state changed

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-5-SFP_OIR Control-ethernet external gigabit sfp [chars] - [chars]

Explanation    The control-eth ext ge sfp state changed

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-7-ERROR [chars] : [chars]

Explanation    An unexpected error condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-7-ERROR [chars] : [chars]

Explanation    An unexpected error condition encountered.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-7-REGISTER_NOTIFY_FAIL CE register notification failed with cb : [hex] intf : [hex] num_elements : [hex]

Explanation    An unexpected failure in register notification failed.

Recommended Action    Collect system log information. No action is required.

Error Message     
 
    
    
   

%PLATFORM-CEMGBL-7-REGISTER_NOTIFY_FAIL CE register notification failed with cb : [hex] intf : [hex] num_elements : [hex]

Explanation    An unexpected failure in register notification failed.

Recommended Action    Collect system log information. No action is required.

CETHHA Messages

Error Message     
 
    
    
   

%PLATFORM-CETHHA-2-CRITICAL Hardware error on control-ethernet port [chars]

Explanation    Hardware error on CPU control ethernet port.

Recommended Action    Remove/Replace the RP.

Error Message     
 
    
    
   

%PLATFORM-CETHHA-2-PORT_FAULT High rate of errors on control ethernet port [chars]

Explanation    The rate of link errors on the control ethernet port has exceeded the threshold. The link should be fixed to avoid disruption in router services.

Recommended Action    Fix the bad link after switching traffic to redundant link.

Error Message     
 
    
    
   

%PLATFORM-CETHHA-4-NOGE RP does not have GE connectivity

Explanation    RP does not have GE connectivity. Reload/failovers may cause problems.

Recommended Action    Check the GE connections on the front panel of the RP/SC and re-connect/replace to make sure atleast one GE connection is there.

Error Message     
 
    
    
   

%PLATFORM-CETHHA-7-STATS_INFO Statistics: [chars]

Explanation    Packet tx/rx statistics on CPU control ethernet port.

Recommended Action    Remove/Replace the RP.

CFP Messages

Error Message     
 
    
    
   

%PLATFORM-CFP-2-DEV_CFP_COMPLIANCE_ERROR CFP Module for port [dec] is not Cisco compliant

Explanation    A compliance error was detected during CFP initialization. A compliance error is due to checksum error, EEPROM CRC error, vendor data error, or decryption error. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. The optics will not be enabled if an CFP compliance error is detected.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show controller i/f phy' and 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-DEV_CFP_OPTICS_PORT_UNSUP CFP Module for port [dec] is not supported

Explanation    A CFP Module not supported for the port error was detected during CFP initialization. A CFP Module not supported for the port error is reported when Optics is not supported on the port. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, SFP OIR and line card process restart. Traffic will not be impacted by this error.

Recommended Action    Verify that the CFP Module is supported for the port. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show controller i/f phy' and 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-DEV_CFP_PID_NOT_SUPPORTED CFP Module for port [dec] is not a supported Product ID (PID)

Explanation    A PID not supported error was detected during CFP initialization. A PID not support error is reported when either the PID can not be read it not supported on the platform. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. Traffic will not be impacted by this error.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show controller i/f phy' and 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-DEV_CFP_SUPPORTED_ERROR CFP Module for port [dec] is not a supported module type

Explanation    A supported error was detected during CFP initialization. A support error is reported when the CFP type can not be determined or it is not supported on the platform. The CFP is the pluggable optics on the line cards. CFP initialization may happen when linecard boots up, CFP OIR and line card process restart. The optics will not be enabled if an CFP supported error is detected.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands 'show controller i/f phy' and 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-HIGH_BIAS_ALARM CFP Case High Bias Alarm

Explanation    Environmental monitoring has detected a CFP case bias greater than or equal to the high bias alarm threshold. The CFP is the pluggable optics on the line cards. The bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-HIGH_TEMP_ALARM CFP Case High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP case temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-HIGH_VOLTAGE_ALARM CFP Case High Voltage Alarm

Explanation    Environmental monitoring has detected an CFP case voltage greater than or equal to the high voltage alarm threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_HIGH_BIAS_ALARM CFP Lane 0 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_HIGH_RX_POWER_ALARM CFP Lane 0 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_HIGH_TEMP_ALARM CFP Lane 0 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_HIGH_TX_POWER_ALARM CFP Lane 0 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_LOW_BIAS_ALARM CFP Lane 0 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_LOW_RX_POWER_ALARM CFP Lane 0 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_LOW_TEMP_ALARM CFP Lane 0 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_0_LOW_TX_POWER_ALARM CFP Lane 0 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_HIGH_BIAS_ALARM CFP Lane 1 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_HIGH_RX_POWER_ALARM CFP Lane 1 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_HIGH_TEMP_ALARM CFP Lane 1 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_HIGH_TX_POWER_ALARM CFP Lane 1 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_LOW_BIAS_ALARM CFP Lane 1 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_LOW_RX_POWER_ALARM CFP Lane 1 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_LOW_TEMP_ALARM CFP Lane 1 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_1_LOW_TX_POWER_ALARM CFP Lane 1 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_HIGH_BIAS_ALARM CFP Lane 10 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_HIGH_RX_POWER_ALARM CFP Lane 10 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_HIGH_TEMP_ALARM CFP Lane 10 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_HIGH_TX_POWER_ALARM CFP Lane 10 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_LOW_BIAS_ALARM CFP Lane 10 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_LOW_RX_POWER_ALARM CFP Lane 10 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_LOW_TEMP_ALARM CFP Lane 10 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_10_LOW_TX_POWER_ALARM CFP Lane 10 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_HIGH_BIAS_ALARM CFP Lane 11 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_HIGH_RX_POWER_ALARM CFP Lane 11 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_HIGH_TEMP_ALARM CFP Lane 11 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_HIGH_TX_POWER_ALARM CFP Lane 11 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_LOW_BIAS_ALARM CFP Lane 11 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_LOW_RX_POWER_ALARM CFP Lane 11 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_LOW_TEMP_ALARM CFP Lane 11 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_11_LOW_TX_POWER_ALARM CFP Lane 11 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_HIGH_BIAS_ALARM CFP Lane 12 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_HIGH_RX_POWER_ALARM CFP Lane 12 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_HIGH_TEMP_ALARM CFP Lane 12 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_HIGH_TX_POWER_ALARM CFP Lane 12 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_LOW_BIAS_ALARM CFP Lane 12 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_LOW_RX_POWER_ALARM CFP Lane 12 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_LOW_TEMP_ALARM CFP Lane 12 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_12_LOW_TX_POWER_ALARM CFP Lane 12 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_HIGH_BIAS_ALARM CFP Lane 13 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_HIGH_RX_POWER_ALARM CFP Lane 13 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_HIGH_TEMP_ALARM CFP Lane 13 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_HIGH_TX_POWER_ALARM CFP Lane 13 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_LOW_BIAS_ALARM CFP Lane 13 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_LOW_RX_POWER_ALARM CFP Lane 13 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_LOW_TEMP_ALARM CFP Lane 13 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_13_LOW_TX_POWER_ALARM CFP Lane 13 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_HIGH_BIAS_ALARM CFP Lane 14 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_HIGH_RX_POWER_ALARM CFP Lane 14 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_HIGH_TEMP_ALARM CFP Lane 14 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_HIGH_TX_POWER_ALARM CFP Lane 14 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_LOW_BIAS_ALARM CFP Lane 14 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_LOW_RX_POWER_ALARM CFP Lane 14 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_LOW_TEMP_ALARM CFP Lane 14 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_14_LOW_TX_POWER_ALARM CFP Lane 14 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_HIGH_BIAS_ALARM CFP Lane 15 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_HIGH_RX_POWER_ALARM CFP Lane 15 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_HIGH_TEMP_ALARM CFP Lane 15 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_HIGH_TX_POWER_ALARM CFP Lane 15 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_LOW_BIAS_ALARM CFP Lane 15 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_LOW_RX_POWER_ALARM CFP Lane 15 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_LOW_TEMP_ALARM CFP Lane 15 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_15_LOW_TX_POWER_ALARM CFP Lane 15 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_HIGH_BIAS_ALARM CFP Lane 2 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_HIGH_RX_POWER_ALARM CFP Lane 2 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_HIGH_TEMP_ALARM CFP Lane 2 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_HIGH_TX_POWER_ALARM CFP Lane 2 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_LOW_BIAS_ALARM CFP Lane 2 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_LOW_RX_POWER_ALARM CFP Lane 2 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_LOW_TEMP_ALARM CFP Lane 2 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_2_LOW_TX_POWER_ALARM CFP Lane 2 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_HIGH_BIAS_ALARM CFP Lane 3 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_HIGH_RX_POWER_ALARM CFP Lane 3 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_HIGH_TEMP_ALARM CFP Lane 3 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_HIGH_TX_POWER_ALARM CFP Lane 3 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_LOW_BIAS_ALARM CFP Lane 3 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_LOW_RX_POWER_ALARM CFP Lane 3 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_LOW_TEMP_ALARM CFP Lane 3 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_3_LOW_TX_POWER_ALARM CFP Lane 3 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_HIGH_BIAS_ALARM CFP Lane 4 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_HIGH_RX_POWER_ALARM CFP Lane 4 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_HIGH_TEMP_ALARM CFP Lane 4 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_HIGH_TX_POWER_ALARM CFP Lane 4 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_LOW_BIAS_ALARM CFP Lane 4 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_LOW_RX_POWER_ALARM CFP Lane 4 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_LOW_TEMP_ALARM CFP Lane 4 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_4_LOW_TX_POWER_ALARM CFP Lane 4 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_HIGH_BIAS_ALARM CFP Lane 5 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_HIGH_RX_POWER_ALARM CFP Lane 5 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_HIGH_TEMP_ALARM CFP Lane 5 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_HIGH_TX_POWER_ALARM CFP Lane 5 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_LOW_BIAS_ALARM CFP Lane 5 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_LOW_RX_POWER_ALARM CFP Lane 5 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_LOW_TEMP_ALARM CFP Lane 5 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_5_LOW_TX_POWER_ALARM CFP Lane 5 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_HIGH_BIAS_ALARM CFP Lane 6 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_HIGH_RX_POWER_ALARM CFP Lane 6 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_HIGH_TEMP_ALARM CFP Lane 6 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_HIGH_TX_POWER_ALARM CFP Lane 6 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_LOW_BIAS_ALARM CFP Lane 6 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_LOW_RX_POWER_ALARM CFP Lane 6 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_LOW_TEMP_ALARM CFP Lane 6 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_6_LOW_TX_POWER_ALARM CFP Lane 6 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_HIGH_BIAS_ALARM CFP Lane 7 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_HIGH_RX_POWER_ALARM CFP Lane 7 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_HIGH_TEMP_ALARM CFP Lane 7 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_HIGH_TX_POWER_ALARM CFP Lane 7 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_LOW_BIAS_ALARM CFP Lane 7 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_LOW_RX_POWER_ALARM CFP Lane 7 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_LOW_TEMP_ALARM CFP Lane 7 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_7_LOW_TX_POWER_ALARM CFP Lane 7 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_HIGH_BIAS_ALARM CFP Lane 8 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_HIGH_RX_POWER_ALARM CFP Lane 8 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_HIGH_TEMP_ALARM CFP Lane 8 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_HIGH_TX_POWER_ALARM CFP Lane 8 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_LOW_BIAS_ALARM CFP Lane 8 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_LOW_RX_POWER_ALARM CFP Lane 8 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_LOW_TEMP_ALARM CFP Lane 8 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_8_LOW_TX_POWER_ALARM CFP Lane 8 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_HIGH_BIAS_ALARM CFP Lane 9 High Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_HIGH_RX_POWER_ALARM CFP Lane 9 High Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_HIGH_TEMP_ALARM CFP Lane 9 High Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_HIGH_TX_POWER_ALARM CFP Lane 9 High Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_LOW_BIAS_ALARM CFP Lane 9 Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_LOW_RX_POWER_ALARM CFP Lane 9 Low Rx Power Alarm

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power alarm threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_LOW_TEMP_ALARM CFP Lane 9 Low Temperature Alarm

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LANE_9_LOW_TX_POWER_ALARM CFP Lane 9 Low Tx Power Alarm

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power alarm threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LOW_BIAS_ALARM CFP Case Low Bias Alarm

Explanation    Environmental monitoring has detected a CFP case bias less than or equal to the low laser bias alarm threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LOW_TEMP_ALARM CFP Case Low Temperature Alarm

Explanation    Environmental monitoring has detected an CFP case temperature less than or equal to the low temperature alarm threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-2-LOW_VOLTAGE_ALARM CFP Case Low Voltage Alarm

Explanation    Environmental monitoring has detected a CFP case voltage less than or equal to the low voltage alarm threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-HIGH_BIAS_WARNING CFP Case High Bias Warning

Explanation    Environmental monitoring has detected a CFP case bias greater than or equal to the high bias warning threshold. The CFP is the pluggable optics on the line cards. The bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-HIGH_TEMP_WARNING CFP Case High Temperature Warning

Explanation    Environmental monitoring has detected a CFP case temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-HIGH_VOLTAGE_WARNING CFP Case High Voltage Warning

Explanation    Environmental monitoring has detected a CFP case voltage greater than or equal to the high voltage warning threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_HIGH_BIAS_WARNING CFP Lane 0 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_HIGH_RX_POWER_WARNING CFP Lane 0 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_HIGH_TEMP_WARNING CFP Lane 0 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_HIGH_TX_POWER_WARNING CFP Lane 0 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_LOW_BIAS_WARNING CFP Lane 0 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_LOW_RX_POWER_WARNING CFP Lane 0 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_LOW_TEMP_WARNING CFP Lane 0 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_0_LOW_TX_POWER_WARNING CFP Lane 0 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_HIGH_BIAS_WARNING CFP Lane 1 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_HIGH_RX_POWER_WARNING CFP Lane 1 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_HIGH_TEMP_WARNING CFP Lane 1 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_HIGH_TX_POWER_WARNING CFP Lane 1 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_LOW_BIAS_WARNING CFP Lane 1 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_LOW_RX_POWER_WARNING CFP Lane 1 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_LOW_TEMP_WARNING CFP Lane 1 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_1_LOW_TX_POWER_WARNING CFP Lane 1 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_HIGH_BIAS_WARNING CFP Lane 10 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_HIGH_RX_POWER_WARNING CFP Lane 10 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_HIGH_TEMP_WARNING CFP Lane 10 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_HIGH_TX_POWER_WARNING CFP Lane 10 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_LOW_BIAS_WARNING CFP Lane 10 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_LOW_RX_POWER_WARNING CFP Lane 10 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_LOW_TEMP_WARNING CFP Lane 10 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_10_LOW_TX_POWER_WARNING CFP Lane 10 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_HIGH_BIAS_WARNING CFP Lane 11 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_HIGH_RX_POWER_WARNING CFP Lane 11 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_HIGH_TEMP_WARNING CFP Lane 11 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_HIGH_TX_POWER_WARNING CFP Lane 11 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_LOW_BIAS_WARNING CFP Lane 11 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_LOW_RX_POWER_WARNING CFP Lane 11 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_LOW_TEMP_WARNING CFP Lane 11 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_11_LOW_TX_POWER_WARNING CFP Lane 11 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_HIGH_BIAS_WARNING CFP Lane 12 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_HIGH_RX_POWER_WARNING CFP Lane 12 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_HIGH_TEMP_WARNING CFP Lane 12 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_HIGH_TX_POWER_WARNING CFP Lane 12 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_LOW_BIAS_WARNING CFP Lane 12 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_LOW_RX_POWER_WARNING CFP Lane 12 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_LOW_TEMP_WARNING CFP Lane 12 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_12_LOW_TX_POWER_WARNING CFP Lane 12 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_HIGH_BIAS_WARNING CFP Lane 13 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_HIGH_RX_POWER_WARNING CFP Lane 13 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_HIGH_TEMP_WARNING CFP Lane 13 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_HIGH_TX_POWER_WARNING CFP Lane 13 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_LOW_BIAS_WARNING CFP Lane 13 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_LOW_RX_POWER_WARNING CFP Lane 13 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_LOW_TEMP_WARNING CFP Lane 13 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_13_LOW_TX_POWER_WARNING CFP Lane 13 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_HIGH_BIAS_WARNING CFP Lane 14 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_HIGH_RX_POWER_WARNING CFP Lane 14 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_HIGH_TEMP_WARNING CFP Lane 14 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_HIGH_TX_POWER_WARNING CFP Lane 14 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_LOW_BIAS_WARNING CFP Lane 14 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_LOW_RX_POWER_WARNING CFP Lane 14 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_LOW_TEMP_WARNING CFP Lane 14 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_14_LOW_TX_POWER_WARNING CFP Lane 14 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_HIGH_BIAS_WARNING CFP Lane 15 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_HIGH_RX_POWER_WARNING CFP Lane 15 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_HIGH_TEMP_WARNING CFP Lane 15 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_HIGH_TX_POWER_WARNING CFP Lane 15 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_LOW_BIAS_WARNING CFP Lane 15 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_LOW_RX_POWER_WARNING CFP Lane 15 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_LOW_TEMP_WARNING CFP Lane 15 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_15_LOW_TX_POWER_WARNING CFP Lane 15 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_HIGH_BIAS_WARNING CFP Lane 2 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_HIGH_RX_POWER_WARNING CFP Lane 2 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_HIGH_TEMP_WARNING CFP Lane 2 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_HIGH_TX_POWER_WARNING CFP Lane 2 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_LOW_BIAS_WARNING CFP Lane 2 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_LOW_RX_POWER_WARNING CFP Lane 2 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_LOW_TEMP_WARNING CFP Lane 2 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_2_LOW_TX_POWER_WARNING CFP Lane 2 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_HIGH_BIAS_WARNING CFP Lane 3 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_HIGH_RX_POWER_WARNING CFP Lane 3 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_HIGH_TEMP_WARNING CFP Lane 3 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_HIGH_TX_POWER_WARNING CFP Lane 3 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_LOW_BIAS_WARNING CFP Lane 3 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_LOW_RX_POWER_WARNING CFP Lane 3 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_LOW_TEMP_WARNING CFP Lane 3 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_3_LOW_TX_POWER_WARNING CFP Lane 3 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_HIGH_BIAS_WARNING CFP Lane 4 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_HIGH_RX_POWER_WARNING CFP Lane 4 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_HIGH_TEMP_WARNING CFP Lane 4 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_HIGH_TX_POWER_WARNING CFP Lane 4 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_LOW_BIAS_WARNING CFP Lane 4 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_LOW_RX_POWER_WARNING CFP Lane 4 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_LOW_TEMP_WARNING CFP Lane 4 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_4_LOW_TX_POWER_WARNING CFP Lane 4 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_HIGH_BIAS_WARNING CFP Lane 5 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_HIGH_RX_POWER_WARNING CFP Lane 5 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_HIGH_TEMP_WARNING CFP Lane 5 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_HIGH_TX_POWER_WARNING CFP Lane 5 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_LOW_BIAS_WARNING CFP Lane 5 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_LOW_RX_POWER_WARNING CFP Lane 5 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_LOW_TEMP_WARNING CFP Lane 5 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_5_LOW_TX_POWER_WARNING CFP Lane 5 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_HIGH_BIAS_WARNING CFP Lane 6 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_HIGH_RX_POWER_WARNING CFP Lane 6 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_HIGH_TEMP_WARNING CFP Lane 6 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_HIGH_TX_POWER_WARNING CFP Lane 6 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_LOW_BIAS_WARNING CFP Lane 6 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_LOW_RX_POWER_WARNING CFP Lane 6 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_LOW_TEMP_WARNING CFP Lane 6 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_6_LOW_TX_POWER_WARNING CFP Lane 6 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_HIGH_BIAS_WARNING CFP Lane 7 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_HIGH_RX_POWER_WARNING CFP Lane 7 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_HIGH_TEMP_WARNING CFP Lane 7 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_HIGH_TX_POWER_WARNING CFP Lane 7 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_LOW_BIAS_WARNING CFP Lane 7 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_LOW_RX_POWER_WARNING CFP Lane 7 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_LOW_TEMP_WARNING CFP Lane 7 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_7_LOW_TX_POWER_WARNING CFP Lane 7 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_HIGH_BIAS_WARNING CFP Lane 8 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_HIGH_RX_POWER_WARNING CFP Lane 8 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_HIGH_TEMP_WARNING CFP Lane 8 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_HIGH_TX_POWER_WARNING CFP Lane 8 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_LOW_BIAS_WARNING CFP Lane 8 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_LOW_RX_POWER_WARNING CFP Lane 8 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_LOW_TEMP_WARNING CFP Lane 8 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_8_LOW_TX_POWER_WARNING CFP Lane 8 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_HIGH_BIAS_WARNING CFP Lane 9 High Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias greater than or equal to the high laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_HIGH_RX_POWER_WARNING CFP Lane 9 High Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power greater than or equal to the high Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. Verify that the input signal has the necessary attenuation. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_HIGH_TEMP_WARNING CFP Lane 9 High Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature greater than or equal to the high temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_HIGH_TX_POWER_WARNING CFP Lane 9 High Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power greater than or equal to the high Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_LOW_BIAS_WARNING CFP Lane 9 Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP laser bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_LOW_RX_POWER_WARNING CFP Lane 9 Low Rx Power Warning

Explanation    Environmental monitoring has detected a CFP Rx power less than or equal to the low Rx power warning threshold. The CFP is the pluggable optics on the line cards. The Rx power threshold values are read from the CFP.

Recommended Action    Verify the following - device is properly inserted. - the RX fiber is inserted properly - the far end is enabled and transmitting - that input attnuation is not too high If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_LOW_TEMP_WARNING CFP Lane 9 Low Temperature Warning

Explanation    Environmental monitoring has detected a CFP laser temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LANE_9_LOW_TX_POWER_WARNING CFP Lane 9 Low Tx Power Warning

Explanation    Environmental monitoring has detected a CFP Tx power less than or equal to the low Tx power warning threshold. The CFP is the pluggable optics on the line cards. The Tx power threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LOW_BIAS_WARNING CFP Low Laser Bias Warning

Explanation    Environmental monitoring has detected a CFP case bias less than or equal to the low laser bias warning threshold. The CFP is the pluggable optics on the line cards. The laser bias threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LOW_TEMP_WARNING CFP Case Low Temperature Warning

Explanation    Environmental monitoring has detected an CFP case temperature less than or equal to the low temperature warning threshold. The CFP is the pluggable optics on the line cards. The temperature threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal' - 'show environment temperatures'

Error Message     
 
    
    
   

%PLATFORM-CFP-3-LOW_VOLTAGE_WARNING CFP Case Low Voltage Warning

Explanation    Environmental monitoring has detected a CFP case voltage less than or equal to the low voltage warning threshold. The CFP is the pluggable optics on the line cards. The voltage threshold values are read from the CFP.

Recommended Action    Verify that the device is properly inserted. If the issue persists then copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the commands - 'show controller i/f phy' - 'show controller i/f internal'

CGV6_SERVICES Messages

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-2-ERR_CGV6_SERVICES_INIT [chars] [hex]

Explanation    An error occurred in initialization of CGV6 Services . If this occurred during process startup or RP Switchover, then the process may be restarted.

Recommended Action    Restart the cgv6_services process (process restart cgv6_services location ) If the issue persists, do a cold reboot Services CGV6 MSC.If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-3-ERROR error: [chars]: [chars]: [hex]

Explanation    A fatal error occurred in the cgv6 services process which involves exiting the process.

Recommended Action    collect the info from 'show diag', 'show platform', 'show inv' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-6-INFO [chars]

Explanation    This is a debug message in the CGV6 SERVICE PROCESS to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    'show logging' to confirm sysdb errors

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-7-DEBUG [chars]: [chars] errno [dec]

Explanation    This is a debug message in the CGV6 SERVICES PROCESS to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    'show logging' to confirm sysdb errors

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-7-GENERIC_ERROR [chars] [hex]

Explanation    A generic error occurred in Services CGV6 SERVICE. Cause of the error will be mentioned in the message displayed.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%PLATFORM-CGV6_SERVICES-7-GENERIC_INFO Info: [chars]

Explanation    The message is used to report generic info about Services CGV6 SERVICES.

Recommended Action    *NONE*

CHP Messages

Error Message     
 
    
    
   

%PLATFORM-CHP-0-FAULT_RECOVERY_ERR The fault recovery procedure for the ToFab component of the fabric driver has failed. The root fault was: [chars]

Explanation    When a hardware fault occurs and the device driver cannot correct it, the Platform Manager is required to reset the ASICs. This error indicates that the Platform Manager failed to reset the ASICs and the hardware on the PRP may not be in an operational state. This condition affects the functionality of the entire router. %s is the Interrupt Source.

Recommended Action    If the system has not failed over automatically and a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0 ' where x is the slot of route processor that generated the error. If no redundant RP is configured you will need to reboot the router by issuing the reload command. Call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-CRC_ERR chopper dll: block: [chars], entity: [chars] had CRC error, count: [dec]

Explanation    PII block got a packet from the entity mentioned above with a CRC error.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-DEVICE_HALT TFQ: device halted, sub-block: [chars], halted entity: [chars]

Explanation    TFQ, ASIC got halted. The halted block and its parent block are provided

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-DMA_ERR Chopper detected a DMA error: Data [hex]

Explanation    This message indicates that the Chopper hardware found a DMA problem. The hexadecimal data indicates the error register value when the problem is detected. This usually indicates a hardware error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-FATAL chopper dll: fatal error encountered, reason equals [chars]

Explanation    iqm, chopper dll manager encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-FATAL_2 chopper dll: fatal error encountered, reason equals [chars], errno equals [dec]

Explanation    chopper encountered a fatal error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-FUSILLI_PARITY_ERR Chopper detected a Fusilli parity error: Data [hex]

Explanation    A parity error has been detected on the Chopper to Fusilli interface. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP. RP may be reset.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-GEN_INFO chopper dll: general information,[chars]

Explanation    The CHP's informational message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-HWINIT_INCOMPLETE chopper dll: hardware initialization not complete

Explanation    hardware init is not complete.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-INFO chopper dll: service degrading error, reason equals [chars]

Explanation    The chopper encountered an error that would lead to degraded service.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-INTR_ENABLE_FAIL chopper dll: intr enable at addr: [hex] mask: [hex] failed.

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-INTR_STATUS_GET_ERR chopper dll: intr status get failed for: [chars]@[hex], rc equals [dec]

Explanation    Hardware register read failed.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-MALLOC_FAILED chopper dll: fatal memory allocation error for [dec] bytes

Explanation    CHP encountered a fatal memory allocation error

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-NOT_AVAILABLE chopper dll: asic is not available

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-NOT_OPERATIONAL chopper dll: asic is not operational, state: [dec]

Explanation    hardware state is not correct.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-NOT_YET_IMPLEMENTED chopper dll: this function [chars] is not yet implemented

Explanation    TFQ, chopper dll , a function is not implemented.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-PCI_ERR Chopper detected a PCI error: Data [hex]

Explanation    A PCI error has been detected by the Chopper PCI interface. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP. RP may be reset.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-3-SRAM_PARITY_ERR Chopper detected a SRAM parity error: Data [hex]

Explanation    A parity error has been detected on the Chopper to SRAM interface. The hex number indicates the error cause register value. This usually indicates a hardware problem on the RP. RP may be reset.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CHP-6-UNHANDLED_HALT chopper dll: halt not handled, parent: [chars], child: [chars], intr: [dec]

Explanation    Hardware halt is not handled.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%PLATFORM-CHP-6-UNHANDLED_INTR chopper dll: intr not handled, parent: [chars], child: [chars], group id: [dec], intr: [dec]

Explanation    Hardware interrupt is not handled in the code, need to implement.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

CIH Messages

Error Message     
 
    
    
   

%PLATFORM-CIH-0-ASIC_ERROR_BOARD_RELOAD [chars][[dec]]: reload board due to too many reset

Explanation    Mulitple reset occurred, need to reload board

Recommended Action    Due to too many reset, board has been reloaded to recover *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-0-ASIC_ERROR_RELOAD_SYS [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need to reload system

Recommended Action    An error has happened and need to reload the system. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-0-ASIC_ERROR_SHUTDOWN_BOARD [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and board need shutdown.

Recommended Action    An error has happened and board is shutdown. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and been handled.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_HARD_RESET [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need a hard reset.

Recommended Action    An error has happen and HARD reset has been performed to recover. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_PON_RESET [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need a power on reset.

Recommended Action    An error has happen and PON reset has been performed to recover. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_REPROG_RESOURCE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need reprogram resource.

Recommended Action    An error that causes reprogram resource has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_REPROG_RESOURCE_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors need to reprogram resource have happened, such errors has crossed threshold.

Recommended Action    Errors that cause reprogram resource have happened and exceeded threshold. The error condition has been handled. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_RETRAIN_LINK [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause retrain link.

Recommended Action    An error that causes retrain link has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_SCRUB_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors have occured and need memory scrubbing, such errors have crossed threshold.

Recommended Action    Errors have been handled. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_SHUTDOWN_LINK_FABRIC [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause fabric link shutdown.

Recommended Action    An error that causeis fabric link shutdown has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_SHUTDOWN_LINK_ILITE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause ilte link shutdown.

Recommended Action    An error that causes ilite link shutdown has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_SPECIAL_HANDLE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and been handled.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_SPECIAL_HANDLE_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors have occured and been handled. Such errors have crossed threshold.

Recommended Action    ASIC errors that need special handling have occured and exceed the threshold. The error condition has been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_PERSIST_THRESHOLD [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error threshold was crossed.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_RELOAD_BOARD [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need to reload board

Recommended Action    An error has happened and board is reloaded. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_REQUEST_RELOAD_BOARD [chars][[dec]]: device is not recovered from fault - and reload is requested.

Explanation    An ASIC error has occured and cause board reload.

Recommended Action    The output message is warning board reload request. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-1-ASIC_ERROR_SHUTDOWN_LINK_ILITE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause ilte link shutdown.

Recommended Action    An error that causes ilite link shutdown has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-2-ASIC_ERROR_HARD_RESET [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and hard reset is needed.

Recommended Action    An error has happened and HARD reset has been performed to recover. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-2-ASIC_ERROR_PON_RESET [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and power on reset is needed

Recommended Action    An error has happen and PON reset has been performed to recover. Collect required information and contact TAC *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-3-ASIC_ERROR_SHUTDOWN_LINK_FABRIC [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause fabric link shutdown.

Recommended Action    An error that causes fabric link shutdown has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-3-ASIC_ERROR_SPECIAL_HANDLE_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors have occured and been handled. Such error have crossed threshold.

Recommended Action    ASIC errors that need special handling have occured and exceed the threshold. The error condition has been handled. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-3-COMMON_ERROR [chars]

Explanation    The CIH library encountered an error related to memory or data value.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-3-MISS_MEM_INFO Leaf node [chars] do not have mem info

Explanation    Missing mem_info while processing error interrupt.

Recommended Action    Error at the memory location will not be corrected in this case. Need add this information to parser generated file *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and been handled.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_ASIC_SCAN ASIC SCAN is needed due to ASIC error [hex] with instance [dec]

Explanation    An ASIC error which requires ASIC SCAN has occured, the ASIC SCAN will be triggered.

Recommended Action    The linecard will be booted after the ASIC SCAN is completed, save the ASIC SCAN output files on the linecard local disk, provide the files to TAC support for further debugging. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_HARD_RESET_START [chars][[dec]]: HARD_RESET needed [hex]

Explanation    An ASIC error has occured and need to hard reset, this marks the beginning of it.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_PON_RESET_START [chars][[dec]]: PON_RESET needed [hex]

Explanation    An ASIC error has occured and need power on reset, this mark the beginning of it.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_REPROG_RESOURCE_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause reprogram resource, such error has crossed threshold.

Recommended Action    Errors that cause reprogram resource have happened and exceed threshold. This has been handled. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_RETRAIN_LINK [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and cause retrain link.

Recommended Action    An error that causes retrain link has happened and been handled *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_SCRUB_THRESH [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors have occured and need memory scrubbing, such errors have crossed threshold.

Recommended Action    Errors have been handled. *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_SPECIAL_HANDLE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error that need special handling has occured and been handled.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-5-ASIC_ERROR_THRESHOLD [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    ASIC errors have exceed the threshold.

Recommended Action    *None*

Error Message     
 
    
    
   

%PLATFORM-CIH-7-ASIC_ERROR_REPROG_RESOURCE [chars][[dec]]: [chars] error has occurred[chars]%s [hex] [chars] [chars]

Explanation    An ASIC error has occured and need to reprogram resource.

Recommended Action    An error that causes reprogram resource has happened and been handled *None*

CLKCTRL_T Messages

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-2-DEV_VERSION_ERROR Timing driver version is not compatible with the hardware FPGA version. S/W ver: [dec]:[dec] H/W ver: [dec]:[dec]

Explanation    Timing driver software version is not compatible with the hardware FPGA version.

Recommended Action    Upgrade the ClkCtrl Timing FPGA image using the FPD procedure. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-2-EEPROM_OVERCURRENT ClkCtrl detected an EEPROM overcurrent condition

Explanation    ClkCtrl detected an EEPROM overcurrent condition

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-2-PARITY_ERROR Timing software detected a parity error address equals [dec] data equals [dec]

Explanation    Timing software detected a parity error from interrupt controller

Recommended Action    If a redundant RSP card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover'. 2 - reload the RSP card that failed with the 'reload location' command in admin mode. If no redundant RSP is configured, you will need to reboot the router by issuing the above reload command. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-INVALID_64K_INPUT_SYNC_0 Invalid signal received for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-INVALID_64K_INPUT_SYNC_1 Invalid signal received for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-PLL_T0_STATE_FREERUN The clock-control T0 PLL (reference clock for all interfaces) is [chars] FREERUN mode.

Explanation    No external reference frequency is available for synchronization, so the T0 PLL output is free-running.

Recommended Action    None. This is just a status indication.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-PLL_T0_STATE_HOLDOVER The clock-control T0 PLL (reference clock for all interfaces) is [chars] HOLDOVER mode.

Explanation    No external reference frequency is available for synchronization, so the T0 PLL output is in holdover, maintaining the most-recent frequency to which it was locked.

Recommended Action    None. This is just a status indication.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-PLL_T4_STATE_FREERUN The clock-control T4 PLL (reference clock for Sync 0 and Sync 1 ports) is [chars] FREERUN mode.

Explanation    No external reference frequency is available for synchronization, so the T4 PLL output is free-running.

Recommended Action    None. This is just a status indication.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_AIS_SYNC_0 Alarm indication signal condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_AIS_SYNC_1 Alarm indication signal condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_FRAME_ERR_SYNC_0 Frame error rate exceeded condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    For UTI mode alarm is raised if frame error rate exceeds 2%.

Recommended Action    1) Ensure valid BITS/UTI signal is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_FRAME_ERR_SYNC_1 Frame error rate exceeded condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    For UTI mode alarm is raised if frame error rate exceeds 2%.

Recommended Action    1) Ensure valid BITS/UTI signal is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_INVALID_10M_CLOCK_SYNC_2 Invalid 10MHz input clock observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 10MHz UTC clock signal has been invalidated possibly due to loss-of-signal condition, offset out of range or phase lock issue.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 10MHz clock is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_LOF_SYNC_0 Loss of frame condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_LOF_SYNC_1 Loss of frame condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_LOS_SYNC_0 Loss of signal condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_LOS_SYNC_1 Loss of signal condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_NO_SATELLITE_AVAILABLE_SYNC_2 The specified [chars] TOD message received at input port indicates no satellite availability for sync [dec] clock-interface

Explanation    The received and parsed GPS TOD message frame from external equipment indicates no satellite availablity, which could possibly indicate that the time-of-day received is not synchronized to a UTC/TAI timescale.

Recommended Action    1) Ensure GPS receiver connectivity on the external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_NO_TOD_MSG_SYNC_2 No TOD messages in the specified [chars] format are received on sync [dec] clock-interface

Explanation    No TOD messages are being detected on the GPS port UART receiver.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_RAI_SYNC_0 Remote alarm indication condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.

Recommended Action    Verify input BITS clock signal is set up correctly.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-RX_ALARM_RAI_SYNC_1 Remote alarm indication condition observed for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.

Recommended Action    Verify input BITS clock signal is set up correctly.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_OC_SYNC_0 Transmit open circuit condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    BITS transmitter has detected an open circuit condition.

Recommended Action    Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_OC_SYNC_1 Transmit open circuit condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    BITS transmitter has detected an open circuit condition.

Recommended Action    Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_SC_SYNC_0 Transmit short circuit condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    Condition raised by BITS transmitter when internal short-circuit resistance is approx 25 ohms or less.

Recommended Action    None.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_SC_SYNC_1 Transmit short circuit condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    Condition raised by BITS transmitter when internal short-circuit resistance is approx 25 ohms or less.

Recommended Action    None.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TAF_SYNC_0 Incorrect frame alignment condition observed for Tx mode [chars] on sync [dec] clock-interface.

Explanation    Condition raised possibly due to incorrect internal BITS transmitter configuration.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TAF_SYNC_1 Incorrect frame alignment condition observed for Tx mode [chars] on sync [dec] clock-interface.

Explanation    Condition raised possibly due to incorrect internal BITS transmitter configuration.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TMF_SYNC_0 Incorrect multi-frame alignment condition observed for Tx mode [chars] on sync [dec] clock-interface.

Explanation    Condition raised possibly due to incorrect internal BITS transmitter configuration.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TMF_SYNC_1 Incorrect multi-frame alignment condition observed for Tx mode [chars] on sync [dec] clock-interface.

Explanation    Condition raised possibly due to incorrect internal BITS transmitter configuration.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TPDV_SYNC_0 Transmit pulse density violation condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    In T1 mode TPDV alarm is raised when the transmit data stream does not meet ANSI T1.403 requirements for transmit pulse density.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL_T-3-TX_ALARM_TPDV_SYNC_1 Transmit pulse density violation condition observed for Tx mode [chars] on sync [dec] clock-interface

Explanation    In T1 mode TPDV alarm is raised when the transmit data stream does not meet ANSI T1.403 requirements for transmit pulse density.

Recommended Action    Re-configure and verify if condition is cleared. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CLKCTRL Messages

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    ClkCtrl Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    ClkCtrl Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    ClkCtrl Driver encountered a fatal error and is not able to recover. The supplied text string will explain the reason. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    ClkCtrl encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    ClkCtrl encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    ClkCtrl encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-INVALID_10M_CLOCK Alarm [chars]. Invalid 10MHz input clock received for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 10MHz UTC clock signal has been invalidated possibly due to loss-of-signal condition, offset out of range or phase lock issue.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 10MHz clock is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-INVALID_10M_CLOCK Alarm [chars]. Invalid 10MHz input clock received for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 10MHz UTC clock signal has been invalidated possibly due to loss-of-signal condition, offset out of range or phase lock issue.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 10MHz clock is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-INVALID_64K_INPUT Invalid signal [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-INVALID_64K_INPUT Invalid signal [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-INVALID_64K_INPUT Invalid signal [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The 64k composite clock signal has been invalidated possibly due to loss-of-signal condition or AMI violations.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Ensure valid 64kHz + 8kHz Japanese timing signal(defined in G.703 Appendix II.1) is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-NO_SATELLITE_AVAILABLE Alarm [chars]. The specified [chars] TOD message received at input port inidicates no satellite availability for sync [dec] clock-interface

Explanation    The received and parsed GPS TOD message frame from external equipment indicates no satellite availablity, which could possibly indicate that the time-of-day received is not synchronized to a UTC/TAI timescale.

Recommended Action    1) Ensure GPS receiver connectivity on the external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-NO_SATELLITE_AVAILABLE Alarm [chars]. The specified [chars] TOD message received at input port inidicates no satellite availability for sync [dec] clock-interface

Explanation    The received and parsed GPS TOD message frame from external equipment indicates no satellite availablity, which could possibly indicate that the time-of-day received is not synchronized to a UTC/TAI timescale.

Recommended Action    1) Ensure GPS receiver connectivity on the external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-NO_TOD_MSG Alarm [chars]. No TOD messages in the specified [chars] format are received on sync [dec] clock-interface

Explanation    No TOD messages are being detected on the GPS port UART receiver.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-NO_TOD_MSG Alarm [chars]. No TOD messages in the specified [chars] format are received on sync [dec] clock-interface

Explanation    No TOD messages are being detected on the GPS port UART receiver.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_AIS Alarm indication signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_AIS Alarm indication signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_AIS Alarm indication signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected AIS defect for incoming signal. AIS is usually an unframed all-ones signal. For T1 mode AIS is declared when the BITS receiver detects four or fewer zeroes in a 3ms period. For E1 mode AIS is declared when the BITS receiver detects fewer than three zeroes in two E1 frames.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Trace and check the source of AIS signal. Possibly an incorrect internal configuration in the service provider equipment, or a failure in their upstream connections.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_FRAME_ERR Frame error rate exceeded condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For UTI mode alarm is raised if frame error rate exceeds 2%.

Recommended Action    1) Ensure valid BITS/UTI signal is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_FRAME_ERR Frame error rate exceeded condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For UTI mode alarm is raised if frame error rate exceeds 2%.

Recommended Action    1) Ensure valid BITS/UTI signal is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_FRAME_ERR Frame error rate exceeded condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For UTI mode alarm is raised if frame error rate exceeds 2%.

Recommended Action    1) Ensure valid BITS/UTI signal is applied at input port.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOF Loss of frame condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOF Loss of frame condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOF Loss of frame condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected OOF defect for incoming signal. For T1 mode OOF is declared when out of every four frame bits two or more frame bits are received in error. For E1 mode OOF is declared when three consecutive incorrect FAS is received. Also for E1 mode(CRC-4 framing) OOF can be declared when 915 or more CRC blocks out of 1000 are received in error. Additionally for E1 mode(CAS signalling) OOF can be declared when two consecutive multiframe alignment words are received in error or, for a period of one multiframe, all bits in timeslot 16 are zero.

Recommended Action    1) Ensure framing format on port matches framing format on the line. 2) Configure to other framing format to check if error clears.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOS Loss of signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOS Loss of signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_LOS Loss of signal condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    For T1 mode LOS is declared (as detected by BITS receiver) when no pulses are detected in a window of 192 consecutive pulse intervals. In E1 and 2048kHz modes LOS is declared when no pulses are detected in a window of 255 consecutive pulse intervals. For UTI mode, LOS is detected by hardware as per J.211 specifications.

Recommended Action    1) Ensure cable connection between the configured interface port and external equipment. 2) Check the cable integrity and cable connectors. The receive pair should be on pins 1,2 on the RJ-45 jack.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_RAI Remote alarm indication condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.

Recommended Action    Verify input BITS clock signal is set up correctly.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_RAI Remote alarm indication condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.

Recommended Action    Verify input BITS clock signal is set up correctly.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-RX_ALARM_RAI Remote alarm indication condition [chars] for Rx mode [chars] on sync [dec] clock-interface

Explanation    The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it is receiving from the upstream equipment.

Recommended Action    Verify input BITS clock signal is set up correctly.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-TX_ALARM_OC Transmit open circuit condition [chars] for Tx mode [chars] on sync [dec] clock-interface

Explanation    BITS transmitter has detected an open circuit condition.

Recommended Action    Ensure cable connection between the configured interface port and external equipment.

Error Message     
 
    
    
   

%PLATFORM-CLKCTRL-3-TX_ALARM_OC Transmit open circuit condition [chars] for Tx mode [chars] on sync [dec] clock-interface

Explanation    BITS transmitter has detected an open circuit condition.