Cisco IOS XR System Error Message Reference Guide, Release 4.0
Fabric Messages
Downloads: This chapterpdf (PDF - 1.1MB) The complete bookPDF (PDF - 53.73MB) | Feedback

Fabric Messages

Table Of Contents

Fabric Messages

CCSQ_DLL Messages

CCSQ_LIB Messages

CCSQ_MGR Messages

FAB_SVR Messages

FABQ Messages

FABRIC_COMM_DRVR Messages

FABRIC_DRIVER_LITE Messages

FABRIC_DRVR_SHARED Messages

FABRIC_DRVR Messages

FABRIC_SRVR Messages

FABRICQ_MGR Messages

FABRICQ Messages

FDI Messages

FEATURE_LPTS Messages

FGID_AGG Messages

FGID_ALLOC Messages

FGID_BCDL_CONSUMER Messages

FGID_LIB Messages

FGID_SVR Messages

FIA_API Messages

FIA Messages

FIFO Messages

FSDB_FADB_MAIN Messages

FSDB_FADB Messages

FSDB Messages

FSTATSA Messages

FSTATSC Messages

FSTATSS Messages

HFR_FSDB_FADB_LTRACE Messages

INGRESSQ_ALARM Messages

INGRESSQ_DLL Messages

INGRESSQ_LIB Messages

INGRESSQ Messages


Fabric Messages


This section contains all Fabric (hardware and software both) related System Error Messages.

CCSQ_DLL Messages

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-2-DEVICE_HALT CCSQ: device halted, sub-block: [chars], halted entity: [chars]

Explanation    CCSQ, ASIC got halted. The halted block and its parent block are provided

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-2-ERR_EIO_TRAIN EIO link training threshold exceeded, link: [dec]

Explanation    Repeated attempts to train the EIO links to the neighboring Asic have failed. No further attempts to retrain the link will be made.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-2-TAKING_NODE_DOWN Taking the node down, Reason: [chars]

Explanation    CCSQ DLL encountered an fatal error mentioned above. The driver triggers MSC node-down to recover from the error.

Recommended Action    This might be a recovery action from a fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-3-ERR_ASIC_GENERIC Block: [chars], Generic Error [chars] at Memory Address [hex].

Explanation    CCSQ encountered a device error that has exceeded its threshold value. Driver takes appropriate action to log and fix the error which may include a device reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-3-ERR_ASIC_MBE Multiple Bit Error in Block: [chars] Error: [chars].

Explanation    CCSQ encountered a multiple bit error in the mentioned block. This error is an uncorrectable error. Driver takes appropriate action to log and fix the error which may include a device reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-3-ERR_INIT [chars]

Explanation    The CCSQ driver failed to initialize the device resulting in the restart of the CCSQ driver process.

Recommended Action    Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ccsq_mgr' Also, collect the fabric snapshot: 'show fabric-snapshot file loc '

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-3-ERR_MEM_ALLOC Error Allocating memory for [chars]

Explanation    The CCSQ dll Memory Allocation Error message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-3-RESET Resetting CCSQ ASIC Device

Explanation    CCSQ, cpuctrl net interface encountered a CRC/Sync Error. This will result in the PIO or CDMA failure.

Recommended Action    If it is possible to isolate the trigger point for the sn link error, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-4-ERR_ASIC_CRC CRC Error: Block:[chars] Error:[chars] Count: [dec]

Explanation    CCSQ block received a packet with a CRC error. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic. This error may cause performance degradation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-4-ERR_ASIC_SN_LINK CpuCtrl Interface RxFIFO Error: [chars]

Explanation    CCSQ, cpuctrl net interface Rx FIFO last sync.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-4-INTR_ENABLE_FAIL Interrupt enable at addr: [hex] mask: [hex] failed.

Explanation    Hardware state is not correct.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-5-ERR_ASIC_PARITY Block: [chars], entity: [chars] had parity error(s), addr: [dec], parity: [dec]

Explanation    In the specified block a parity error encountered at mentioned addr offset. If the error exceeds its threshold, the driver trigger a corrective action which may include device reset or MSC reload.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-5-ERR_ASIC_SBE Single Bit Error in Block: [chars] Error: [chars].

Explanation    CCSQ encountered a single bit error in the mentioned block. Persistent errors are corrected by the software. Non-persistent errors are automatically corrected by the next write operation.

Recommended Action    This error is an correctable error. There are no side effects. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_DLL-7-ERR_REGISTER_GET Register get failed for address [hex], Reason: [chars]

Explanation    An attempt to read a Hardware register failed. This could result in inconsistent behavior of the device.

Recommended Action    Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the read failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CCSQ_LIB Messages

Error Message     
 
    
    
   

%FABRIC-CCSQ_LIB-7-ERR_LWM_SEND CCSQ Lib: LWM Message send failed msg: [dec], retried: [dec] time(s), errno: [chars]

Explanation    Unable to send a LWM message to the CCSQ server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CCSQ_MGR Messages

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    CCSQ manager encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    CCSQ encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_BAG_REG Bag register failed for rules. Reason: [chars]

Explanation    EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_CLIENT_REG Client [chars] failed. Reason: [chars]

Explanation    CCSQ Manager client Registration/Unregistration error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_DLL_INIT Dll Initialization for [chars] failed. Reason: [chars]

Explanation    CCSQ driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_EVM_CREATE Event Manager create failed for [chars]. Reason: [chars]

Explanation    CCSQ Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]. Reason: [chars]

Explanation    CCSQ Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed. Reason: [chars]

Explanation    CCSQ Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_LWM_REPLY An error occurred during LWM message reply. Reason: [chars]

Explanation    CCSQ LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-CCSQ_MGR-7-ERR_SYSDB_EDM_REG Sysdb Register EDM failed. Reason: [chars]

Explanation    CCSQ Sysdb Register EDM error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FAB_SVR Messages

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_ASIC_INIT Failed to initialize the CPU control ASIC interface to [chars]: [chars]. Exiting...

Explanation    Fabric server encountered an error while initializing the CPU control ASIC to either receive packets from the fabricq ASIC or transmit packets from the ingressq ASIC. This is crucial for the process and is automatically restarted on this failure.

Recommended Action    If problem either persists (following a process restart) then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_CREATE Failed to create event connection to EVM, Reason: [chars]([dec]). Exiting...

Explanation    Fabric server encountered an error while trying to create a connection to event manager to manage the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_EVM_HANDLER Failed to register event handler, Reason: [chars]([dec]). Exiting...

Explanation    Fabric server encountered an error while trying to register event handler for the posix message queue. This facility is deemed crucial and the process automatically restarts on this failure.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_NOTIFY Failed to register handler for disconnection with EVM, Reason: [chars]([dec]). Exiting...

Explanation    Fabric server encountered an error while trying to register event handler for disconnection or connection error event. This facility is deemed crucial and the process automatically restarts on this failure.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_EVENT_CONN_OPEN Failed to open connection with EVM, Reason: [chars]([dec]). Exiting...

Explanation    Fabric server encountered an error while trying to open connection with event manager. This facility is deemed crucial and the process automatically restarts on this failure.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_EVM_CREATE Failed to create the event manager. Reason: [chars]. Exiting...

Explanation    Fabric server encountered an error while attempting to create an event manager. This failures affects the ability of the process to service various messages / pulses from other threads / processes. This facility is deemed crucial and the process automatically restarts on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_INIT [chars] during the initialization. Reason: [chars]. Exiting...

Explanation    Fabric server encountered the specified error during the initialization sequence. This facility is deemed crucial and hence the process is automatically restarted on this failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_THREAD_ATTRIBUTE Failed to set the thread attribute: [chars]. Exiting...

Explanation    Fabric server encountered an error while setting the thread attribute during the process initialization sequence. This is crucial for the process and is automatically restarted on this failure.

Recommended Action    If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location loc If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FAB_SVR-7-ERR_THREAD_MUTEX_INIT Failed to initialize a mutex for client with ID [dec]: [chars]. Exiting...

Explanation    Fabric server encountered an error while creating a mutex for use by a client with the specified ID. This is crucial for the process and is automatically restarted on this failure.

Recommended Action    If the problem is experienced only by this process in the system, restart the fabric server process by executing the following command at the CLI of the active RP: process restart fab_svr location loc If problem either persists (following a process restart) or also noticed on other processes then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FABQ Messages

Error Message     
 
    
    
   

%FABRIC-FABQ-0-PRP3_FAULT_RECOVERY_ERR ToFab component of the fabric driver has failed. The root fault was: [chars]

Explanation    When a hardware fault occurs and the device driver cannot correct it, the Platform Manager is required to reset the ASICs. This error indicates that the Platform Manager failed to reset the ASICs and the hardware on the PRP may not be in an operational state. This condition affects the functionality of the entire router. %s is the Interrupt Source.

Recommended Action    If the system has not failed over automatically and a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0 ' where x is the slot of route processor that generated the error. If no redundant RP is configured you will need to reboot the router by issuing the reload command. Call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-2-PRP3_DRVR_INIT_ERROR Process initialization failed: [chars] Reason: [chars]

Explanation    PRP fabric queue process failed to initialize. The fabric driver process handles fabric connectivity. It initializes the packet FPGA and coordinates with that fabric DLLs that allow applications to send and receive packets via the fabric. An unrecoverable failure of the process may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-2-PRP3_PKT_INIT_ERROR Packet carving failed to initialize: [chars] Reason: [chars]

Explanation    Initial carving of a packet particle pool failed. Platform specific memory region, packet header and particle pool configuration information are required by the generic packet manager process (PAKMAN) to operate. A failure in packet carving initialization may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-FATAL FABQ: fatal error encountered, reason equals [chars]

Explanation    Fabric Queue Driver encountered a fatal error and is not able recover from the error. A reason text will be supplied. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-INIT_ERROR Process initialization failed: ([chars]%s)

Explanation    PRP fabric queue process failed to initialize. The fabric queue process handles fabric connectivity. It initializes and starts up the threads in ToFab and FrFab components. An unrecoverable failure of the process may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_ERROR Packet carving failed to initialize: ([chars]%s)

Explanation    Initial carving of a packet particle pool failed. Platform specific memory region, packet header and particle pool configuration information are required by the generic packet manager process (PAKMAN) to operate. A failure in packet carving initialization may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_FAIL PKT_INIT: [chars] failed, rc equals [dec], reason:[chars]

Explanation    Packet carving function has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_POOL PKT_INIT: particle_multi_pool_define failed ([chars]), rc equals [dec], reason:[chars]

Explanation    Initial carving of a packet particle pool has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_FABMSG Fabric messaging infrastructure failed: [chars] Reason: [chars]

Explanation    PRP fabric messaging infrastructure failed. The fabric driver process handles fabric connectivity. It initializes the packet FPGA and coordinates with that fabric DLLs that allow applications to send and receive packets via the fabric. An unrecoverable failure of the process may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_FRFAB_PKT_NO_STREAM Client ID([dec]) Port([dec]) From Fabric Packet from slot [dec] has invalid Stream ID([dec])

Explanation    The packet received from the fabric begins with a header with Stream ID not initialized. The issue can happen due to hardware issue or the sender of the packet encoded invalid information in the packet header. %d - Client ID. Every process that uses the fabric API has an unique Client ID. %d - Port number (0 to 15) %d - Sender's slot number (0 to 15) %d - Stream ID encoded in the packet's header

Recommended Action    If the error recurs very frequently call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_FRFAB_PKT_STARTOFFSET Client ID([dec]) Port([dec]) From Fabric Packet from slot [dec] has invalid Start Offset([dec])

Explanation    The packet received from the fabric begins with a header with Start Offset less than the required. This suggests the packet is corrupted. The issue can happen due to hardware issue or the sender of the packet encoded invalid information in the packet header. %d - Client ID. Every process that uses the fabric API has an unique Client ID. %d - Port number (0 to 15) %d - Sender's slot number (0 to 15) %d - Start Offset encoded in the packet's header

Recommended Action    If the error recurs very frequently call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_FRFAB_TAIL_PAR_ERR Client ID([dec]) Port([dec]) Fabric FPGA detects Parity error from a packet received from the Fabric

Explanation    The Hummer detects a parity error on a packet received from the fabric. This is likely due to a hardware issue, or software misconfigured the hardware. %d - Client ID. Every process that uses the fabric API has an unique Client ID. %d - Port number (0 to 15)

Recommended Action    The prp3_fabric_driver process should be able to detect the error and decide to reset fabric FPGA if necessary. If the error is persistent, and router traffic is affected, and if the system has not failed over automatically and a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode 'reload location RP/0/x/CPU0 ' where x is the slot of route processor that generated the error. If no redundant RP is configured you will need to reboot the router by issuing the reload command. Call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_HW_IRQ_ERR Hummer Port([dec]) Interrupt- type([dec]) - [chars]: Reason: [chars]

Explanation    An error is detected when the software is trying to service an interrupt from the Hummer FPGA. Hummer is the fabric packet processing FPGA on the route processor. There are 16 bidirectional ports for 16 different traffic streams. A Hummer port needs to be enabled in the hardware level in order to function. A failure in servicing the Hummer interrupt may prevent this route processor from communicating with other cards in the chassis. %d - indicates the port number (0 to 15) %d - interrupt number that identifies the interrupt type %s - a description of the interrupt event failure %s - is the error reason

Recommended Action    Try restarting the process where the error message was found. Otherwise, try the following: If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_IRQ_ERR Fabric FPGA Error Interrupt: [chars]

Explanation    An error is detected when the software is trying to service an interrupt from the Hummer fabric FPGA. Hummer is the fabric packet processing FPGA on the route processor. There are 16 bidirectional ports for 16 different traffic streams. A Hummer port needs to be enabled in the hardware level in order to function. An error status interrupt may indicate a hardware condition that may prevent this route processor from communicating with other cards in the chassis.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_PORT_DISABLE_ERR Cannot disable Hummer port([dec]): Reason: [chars]

Explanation    Failed to disable Hummer port. Hummer is the fabric packet processing FPGA on the route processor. There are 16 bidirectional ports for 16 different traffic streams. A Hummer port needs to be enabled in the hardware level in order to function. A failure in disabling the Hummer port may prevent this route processor from communicating with other cards in the chassis. It points to a HW issue or a serious software defects. %d - indicates the port number (0 to 15) %s - is the error reason.

Recommended Action    Try restarting the process where the error message was found. Otherwise, try the following: If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_PORT_ENABLE_ERR Cannot enable Hummer port([dec]): Reason: [chars]

Explanation    Failed to enable Hummer port. Hummer is the fabric packet processing FPGA on the route processor. There are 16 bidirectional ports for 16 different traffic streams. A Hummer port needs to be enabled in the hardware level in order to function. A failure in enabling the Hummer port may prevent this route processor from communicating with other cards in the chassis. %d - indicates the port number (0 to 15) %s - is the error reason.

Recommended Action    Try restarting the process where the error message was found. Otherwise, try the following: If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_REUSE_NO_BUFFER Client ID([dec]) Port([dec]) Packet passed to client cannot be reused since there is No Buffer

Explanation    The packet processing code formats packets from the fabric and passes them to the clients. When the client finished with the packet, the packet processing code cannot reuse the packet buffer because none is found associated with the packet. The issue can happen due to a software issue with the client. %d - Client ID. Every process that uses the fabric API has an unique Client ID. %d - Port number (0 to 15)

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_SHM Shared Memory failed during [chars]: [chars]

Explanation    An internal software error occurred that prevented the fabric interface from working properly with shared memory.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_TOFAB_CREDIT_CNT_EXCEEDED RP To Fabric Credit Count([dec]) for destination slot [dec] is greater than the limit. Port([dec])

Explanation    PRP3 fabric hardware requires software to track To Fabric hardware resources for each chassis slot. During the update of this shared per slot information, software detected the resources for this slot exceeded that actual maximum available. This is likely the side affect of a packet resource management event in the fabric driver DLL. %d To Fabric count that exceeds maximum %d The slot associated with the error %d The fabric application port that detected the error (but not necessarily the port that caused the error.

Recommended Action    The error is likely a software bug in tofab packet error or process restart handling. Copy the error message exactly as it appears and report it to your Cisco technical representative together with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_TOFAB_QUEUE_BLOCKED RP To Fabric Queue slot:[dec] is Blocked, report fault to Sysldr

Explanation    The PRP3 to fabric queue of the particular priority and slot is blocked. This means packets that go that slot of that priority will fail. In addition, at least one of the multicast queues (high or low priority) is blocked as well. This likely means the particular slot is failing to accept packets and will cause backpressure on the PRP to fabric queue. Because of hardware design, if a multicast packet includes the one faulty slot then it will be stuck in the tofab multicast queue, and subsequent multicast packets will be stuck even if they do not include the faulty slot in their slotmask. Having the unicast queue blocked is somewhat allowable, but having the multicast queue blocked is not acceptable. This error message is raised when both unicast and multicast are blocked. In order to alleviate this problem, the fault is sent to sysldr, for sylsdr to decide to reload the slot. It is very likely that the problem slot was not accepting packets. slot:%d - is the slot that is back pressuring to the PRP

Recommended Action    The slot should be reloaded to correct the problem, if not done already by sysldr. Copy the error message exactly as it appears and report it to your Cisco technical representative together with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PRP3_TX_DONE_RING RP To Fabric Tx Done Ring. Port:[dec], Tx Index: [dec]: [chars]

Explanation    While servicing To Fabric packets which the PRP3 Fabric FPGA indicates have been transmitted, software detects differences between hardware packet list and software cache of what was to be transmitted. Port:%d the PRP3 hardware fabric port that reported the issue Index:%d the index of the Tx Done Ring when error reported %s a description of the To Fabric event failure

Recommended Action    Copy the error message exactly as it appears and report it to your Cisco technical representative together with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-SHOW_ERR FABQ_SHOW: fatal error encountered: [chars]

Explanation    Error while executing a show command

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-6-PKT_INIT_INFO PKT_INIT: pak mem size:[hex], pak mem start: [hex], pak scaling:[dec]

Explanation    Information on packet memory carving

Recommended Action    This is information and does not require any correction.

Error Message     
 
    
    
   

%FABRIC-FABQ-7-PKT_INIT_INFO Packet initialization: pak mem size:[hex], pak mem start: [hex], pak scaling:[dec]

Explanation    Information on packet memory carving.

Recommended Action    This is informational and does not require any correction.

Error Message     
 
    
    
   

%FABRIC-FABQ-7-PRP3_PKT_INIT_INFO Packet initialization: pak mem size:[hex], pak mem start: [hex], pak scaling:[dec]

Explanation    Information on packet memory carving.

Recommended Action    This is debug-level informational and does not require any correction.

FABRIC_COMM_DRVR Messages

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERR_DRV_INIT Initialization of fabric driver failed: [chars] ; exiting...

Explanation    Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERR_EVM_CREATE SFE driver failed to create event manager for [chars].

Explanation    The SFE common infra driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERR_INTERNAL_SW [chars]; [chars]

Explanation    The SFE common infra driver encountered a SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERR_MEM_ALLOC SFE common infra driver was unable to allocate [dec] bytes

Explanation    The SFE common infra driver was unable to allocate memory. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERRRATE_EXCEED_GLACIAL [chars] ; Node Key equals [hex]

Explanation    The Fabric driver encountered the annunciated error. For Error Node Keys - 0x1050016; 0x1050018; 0x105001A : This indicates a hardware problem in Fabric ASIC. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERRRATE_EXCEED_NO_LIMIT [chars]

Explanation    The fabric driver encountered the annunciated error. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-3-ERRRATE_EXCEED_SLOW [chars]

Explanation    The fabric driver encountered the annunciated error. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-7-ERR_LTRACE_INIT SFE common infra driver failed to initialize the ltrace file [chars]; rc equals [chars]

Explanation    The SFE common infra driver could not open the ltrace buffer. The SFE common infra driver and the system should function as normal, with the exception that ltrace will not be available for sfe_drvr process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-7-ERR_SHM_INIT SFE common infra driver failed to initialize shm [chars]; rc equals [chars]

Explanation    The SFE common infra driver could not initialize shelfmgr.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_COMM_DRVR-7-ERRRATE_EXCEED_DEBUG [chars]

Explanation    The fabric driver encountered the annunciated error. The Fabric driver and the System should still continue to function as normal.

Recommended Action    No action is required.

FABRIC_DRIVER_LITE Messages

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-3-ERR_ASIC_ACCESS_EXCEPTION Fabric ASIC access timed out (reported by lite process)

Explanation    This indicates that the fabric ASIC failed to acknowledge an access request from the CPU. This can happen if the host CPU tries to access an address that is out of range for the ASIC. Also, accessing a register from a block that is still in the logic reset state could stall this access and subsequent accesses to the ASIC.

Recommended Action    If this condition is noticed for every access to the ASIC, then the ASIC is possibly wedged. Resetting the ASIC or reloading the fabric card will help to recover from this condition. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-3-ERR_DRIVER_INIT Initialization of fabric driver lite failed: [chars] ; exiting...

Explanation    Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr_lite) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-3-ERR_EVM_CREATE Failed to create event manager for '[chars]'

Explanation    The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr_lite) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-3-ERR_SHMEM_INIT Shared Memory Error: [chars]

Explanation    Attempt to init/open the shared memory fails

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-3-ERR_THREAD_ATTRIBUTE FABRIC driver lite failed to change interrupt thread to an IO thread: [chars]

Explanation    The Fabric driver was unable to change the interrupt thread to an IO thread. Because of this failure, the interrupt thread will not be able to receive the interrupt thread events. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr_lite) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-4-ERR_LTRACE_INIT Fabric driver lite failed to initialize the ltrace - rc equals [chars]

Explanation    The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the system should still function as normal, with the exception that ltrace will not be available for sfe_drvr process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRIVER_LITE-6-ASIC_INITIALIZED Fabric ASICs initialized (reported by lite process)

Explanation    This indicates Fabric ASICs are initialized and is expected during normal operation.

Recommended Action    No action is required.

FABRIC_DRVR_SHARED Messages

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR_SHARED-2-ERR_SHMEM_INIT Initialization of shared memory failed: [chars]

Explanation    Fabric driver encountered the annunciated error during the shared memory initialization. The fabric driver cannot complete the initialization of the fabric ASICs.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FABRIC_DRVR Messages

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_BOARD_FAULT [chars]. Register: [hex] Current Status: [hex]. Expected Status: [hex].

Explanation    Fabric board is not operational due to the indicated fault. This information is extracted from the fabric PLD registers.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_CCTL_POWER_FAULT Fabric CPLD detects power fault: [chars].

Explanation    Fabric CPLD detects the specified power fault. If the failure is for the LTC2978 device, then this error is due to the failure of the cctl library function call.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_HALT_VIA_CPLD Failed to halt [chars] using CPLD halt assert signal. Halting ASIC via its internal register.

Explanation    The specified device could not be halted using the CPLD register. Use the fabric ASICs internal register to halt the device. This message is meant to catch specific hardware failure.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_HW_HEALTH_MON [chars].

Explanation    The fabric driver verifies the hardware interfaces between the various components on the fabric board. This is done on cold start (POST) and periodically there after. This message is annunciated when any of the tests fail.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_HW_INIT [chars].

Explanation    The board initialization failed the specified operation while configuring the device. The driver will exit and attempt to come up again. On multiple such failures, the board will be shutdown permanently by the shelf manager.

Recommended Action    Collect console logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_LOCALBUS_FAULT Fabric CPLD detects localbus fault: [chars].

Explanation    Fabric CPLD detects the specified local bus fault.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-1-ERR_THRESHOLD_ASIC_RESETS_REACHED Reload fabric card as [chars] was reset for maximum allowed times ([dec])

Explanation    A fabric ASIC may be reset a maximum of 5 times and thereafter the fabric driver requests for the card to be reloaded. On the fifth reset, the card is reloaded.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-2-ERR_MAINTENANCE_MODE Failed to put card in maintenance mode by sysmgr. error code([hex]) - [chars]

Explanation    Fabric driver detected hardware errors and requested sysmgr to place the card in maintenance mode. But sysmgr failed to do so. The card and its fabric ASICs should have been isolated from the system before attempting going to maintenance mode.

Recommended Action    Check the health of the sysmgr process on the node. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-2-ERR_SHUTDOWN Failed to shutdown by shelfmgr. error code([hex]) - [chars]

Explanation    Fabric driver detected hardware errors and requested shelfmgr to shut down the node. But shelfmgr failed to do so. The card and its fabric ASICs should have been isolated from the system before the shutdown attempt.

Recommended Action    Check the health of the shelfmgr process on the RP in its rack. If shelfmgr is healthy, and the card cannot self reload, then reload the card with the following command in admin mode: 'hw shut loc y/SMx/sp', where x is the SM module number that generated the error, y is the rack that it is in. If manual shutdown does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-BM_DEAD_NODE_FAILURE BM Dead Node Failure Occurred for Aggregation Node ([chars]) : ([chars]).

Explanation    All the receive links for a particular stage have gone down triggering the ASIC to go into BM Dead Node. Software will auto recover. Dead node is expected to be seen during plane shut as well as SM OIR where it will result in all receive links of a particular stage to go down.

Recommended Action    If the error is seen at steady state, software will auto recover. Verify that the fabric is stable. If fabric appears unstable, collected fabric show tech.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-BM_DEAD_NODE_RECOVERY_FAILURE BM Dead Node Recovery Failure Occurred, Dead Node Status ([chars]) : ([hex]).

Explanation    We were unable to recover from dead node state. We attempted 3 times, but dead node clearing recovery is failing.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-CCI_INTR_INIT_FAIL Fabric driver failed to initialize the CPLD interrupts with CCI: err code([hex])

Explanation    Fabric driver cannot initialize the CPLD interrupts with CCI infrastructure. The node may not be able to handle CPLD interrupts.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-CCI_LIB_INIT_FAIL Fabric driver failed to initialize the CPU Controller Interface library: err code([hex])

Explanation    Fabric driver cannot initialize the CPU Controller Interface library infrastructure for CPLD initialization and handling. Fabric ASICs access is also compromised.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-CIH_LIB_INIT_FAIL Fabric driver failed to initialize the Common Interrupt Handling library: err code([hex])

Explanation    Fabric driver cannot initialize the Common Interrupt library infrastructure for interrupt and error handling and logging. The node might not be able to handle interrupts.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-DBG_TCAM_LIB_INIT_FAIL Fabric driver failed to initialize the Debug TCAM library: err code([hex])

Explanation    Fabric driver cannot initialize the Debug TCAM library. The node may be not be able to use the debug TCAM to debug cell flows through the fabric ASICs.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_FAULT [chars]: [chars].

Explanation    Fabric driver cannot proceed due to the indicated error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_FGID_SRAM_BIST_DONE FGID SRAM BIST failed to complete for [chars]. Result of SRAM BIST: [hex]

Explanation    This message is seen when the FGID SRAM BIST operation fails to complete after a request is issued to start it for the identified ASIC. The result of the BIST operation for that ASIC is also captured in the message. This condition implies that the ASIC is either not powered up or it is not properly reset at initialization.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_FGID_SRAM_BIST_PASS FGID SRAM BIST failed for [chars]. Pass status: [hex] Expected Pass status: [hex]

Explanation    This message is seen when the FGID SRAM BIST is completed without the necessary pass bits being set for the identified ASIC. Observed pass bits status and the expected status for the ASIC are also captured in the message. The pass status is a 3 bit status i.e. one per SRAM. Number of SRAMs depend on the fabric stage and the fabric board as specified below: S2 Card: 3 SRAMs i.e. SRAM A, SRAM B & SRAM C. S2 ASIC on S123 Cards (all LCC flavors): 1 SRAM i.e. SRAM A. S3 ASIC on S123 & S13 Cards (all LCC flavors): 2 SRAMs i.e. SRAM A & SRAM B. Pass status bit positions: SRAM A: bit 2 SRAM B: bit 1 SRAM C: bit 0.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_HARD_RESET ASIC [chars] in error & halted. Hard reset to recover.

Explanation    Identified Fabric ASIC experienced a severe error and is halted. Hard reset & re-initialize the ASIC to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_PON_RESET ASIC [chars] in error & halted. Power-On reset to recover.

Explanation    Identified Fabric ASIC experienced a severe error and is halted. Power on reset & re-initialize the ASIC to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_SCAN_UNSUPPORTED Combined SPB-motherboard for JTAG not supported. Ensure 73 level base number is 12773

Explanation    SPB is not designed for supporting SPB-motherboard JTAG operation necessary for asic scan functionality. SPB board with this support will have a 73 level base number of 12773. This value is programmed in the SPB EEPROM at locations 42 to 44.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_ASIC_SYSLOG [[chars]]: [chars][LEAF ID: [hex]]; TYPE:[chars] [[chars]]; SYSTEM EFFECT:[chars]; ACTION TAKEN:[chars].

Explanation    This message is logged whenever an ASIC detects an error. This message includes: ASIC identifier, interrupt name & its ID, Interrupt type, effect of the error on the system & the software action taken.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_BOARD_ALERT [chars]. Current Status: [hex]. Expected Status: [hex].

Explanation    Power controllers on the fabric card are raising the alerts indicating that either the voltages or temperature on the card is at its tolerance limits.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_BOARD_PLD_VERSION Fabric Board PLD Version ([dec]) not supported. Upgrade to latest.

Explanation    This indicates that the fabric board is running with PLD version that is not supported. Version lower than (0x1c) is not supported. Please upgrade to the latest PLD Version.

Recommended Action    Shut down the plane associated to this fabric card, and upgrade the PLD Version of this board. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_DRV_INIT Initialization of fabric driver failed: [chars] ; exiting...

Explanation    Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_DRV_INIT Initialization of fabric driver failed: [chars] ; exiting...

Explanation    Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_EVM_CREATE Failed to create event manager for '[chars]'

Explanation    The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_EVM_CREATE Failed to create event manager for '[chars]'

Explanation    The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_FGID_ACCESS Fabric Board Going down. FGID access being aborted.

Explanation    One or more ASICs for the stage on the fabric card are being reset. Hence this multicast FGID access operation for the specified stage is aborted. This may be seen on any SM node going down, during asic reset cleanup process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_FGID_REFRESH Request [dec] to refresh FGID entry [hex].

Explanation    An FGID entry is disabled following a parity error. A request to refresh the entry is issued.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_FGID_REFRESH_RETRY Failed to refresh FGID entry. Reload the fabric card.

Explanation    An FGID entry is disabled following a parity error. Request to refresh the entry wasn't entertained. This will reload the fabric card to recover.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_FGID_WRITE Device(s) being reset. [chars] FGID write to offset [hex] aborted.

Explanation    One or more ASICs for the stage on the fabric card are in being reset. Hence this multicast FGID write operation for the specified stage is aborted.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_INVALID_INSTANCE Access to invalid device id ([dec]).

Explanation    This indicates that an attempt to access internal information was made to an invalid device id.

Recommended Action    None. software error handling will recover.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_LIB_INIT_FAIL Fabric driver failed to initialize ASIC error infrastructure: err code([hex])

Explanation    Fabric driver cannot initialize the ASIC error infrastructure for recording ASIC errors and interrupts. The node is compromised in handling those errors.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_MAX_TOPO_TIME_OUT Maximum attempts to receive topology information exceeded. Restarting sfe_drvr ...

Explanation    This indicates that the maximum tries for the driver to receive the necessary topology information to initialize the asic has exceeded. The driver will not continually re-request topology information.

Recommended Action    Check if all the required fabric cards are UP and running.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_MAX_TOPO_TIME_OUT Maximum attempts to receive topology information exceeded. Restarting sfe_drvr ...

Explanation    This indicates that the maximum tries for the driver to receive the necessary topology information to initialize the asic has exceeded. The driver will not continually re-request topology information.

Recommended Action    Check if all the required fabric cards are UP and running.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_POD_INIT Failed to [chars] POD (node: [hex], module: [hex], asic: [unsigned int], POD:[unsigned int]) - error : [chars]; exiting...

Explanation    Fabric Driver failed to initialize one of the POD hardware modules. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_POD_INIT Failed to initialize POD for node: [hex], error : [chars]; exiting...

Explanation    Fabric Driver failed to initialize one of the POD hardware modules. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_RELOAD Failed to reload. [chars]

Explanation    Fabric driver encountered an error when trying to reload. The card cannot be reloaded at the time of the message. Fabric driver may retry again when resources and conditions are met. The card and its fabric ASICs should have been isolated from the system.

Recommended Action    Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card does not reload after waiting for minutes, reload the card with the following command in admin mode: 'reload loc 0/SMx/sp', where x is the SM module number that generated the error. If manual reload does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_RMA_CARD Persistent errors seen on ASIC [chars]. Shutdown the fabric card.

Explanation    The ASIC on the fabric board is faulty and being taken out of operation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_SELF_RELOAD Failed to reload by shelf-mgr [hex] [[chars]]. Self-reloading...

Explanation    Fabric driver encountered a system error which shelf-mgr cannot reload the node. The fabric driver self-reloads instead. The card and its fabric ASICs should have been isolated from the system before the self-reload.

Recommended Action    Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card cannot self reload, then reload the card with the following command in admin mode: 'reload loc y/SMx/sp', where x is the SM module number that generated the error, and y is the rack that it is in. If manual reload does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_SELF_RELOAD Failed to reload by shelfmgr. error code([hex]) Self-reloading...

Explanation    Fabric driver encountered a system error which shelfmgr cannot reload the node. The fabric driver self-reloads instead. The card and its fabric ASICs should have been isolated from the system before the self-reload.

Recommended Action    Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card cannot self reload, then reload the card with the following command in admin mode: 'reload loc y/SMx/sp', where x is the SM module number that generated the error, and y is the rack that it is in. If manual reload does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_STUCK_BARRIER_FLOW Barriers stuck for type [dec] at phase [dec] [curr: [hex] prev: [hex]] on [chars].

Explanation    Barrier flow of certain type is stuck at identified phase on the specified ASIC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_THREAD_ATTRIBUTE FABRIC driver failed to change interrupt thread to an IO thread: [chars]

Explanation    The Fabric driver was unable to change the interrupt thread to an IO thread. Because of this failure, the interrupt thread will not be able to receive the interrupt thread events. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_THREAD_ATTRIBUTE FABRIC driver failed to change interrupt thread to an IO thread: [chars]

Explanation    The Fabric driver was unable to change the interrupt thread to an IO thread. Because of this failure, the interrupt thread will not be able to receive the interrupt thread events. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_TIMER_START Leaf Timer Failed to start. Timer Type: [dec].

Explanation    Fabric driver could not start timer.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_WAITING_FOR_TOPO_TIMED_OUT Driver timed out waiting for topology information. Attempt re-request for topology.

Explanation    This indicates that the driver has not received the necessary topology information to initialize the asic. The driver will continually re-request topology. This message can also be seen in a multichassis system when a fabric card is pulled out or powered down and the other end is still up and running or if the plane config for this card is missing.

Recommended Action    Check if all the required fabric cards are UP and running.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERR_WAITING_FOR_TOPO_TIMED_OUT Driver timed out waiting for topology information. Attempt re-request for topology.

Explanation    This indicates that the driver has not received the necessary topology information to initialize the asic. The driver will continually re-request topology. This message can also be seen in a multichassis system when a fabric card is pulled out or powered down and the other end is still up and running or if the plane config for this card is missing.

Recommended Action    Check if all the required fabric cards are UP and running.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_GLACIAL [chars] ; Node Key equals [hex]

Explanation    The Fabric driver encountered the annunciated error. For Error Node Keys - 0x1050016; 0x1050018; 0x105001A : This indicates a hardware problem in Fabric ASIC. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_GLACIAL [chars] ; Node Key equals [hex]

Explanation    The Fabric driver encountered the annunciated error. For Error Node Keys - 0x1050016; 0x1050018; 0x105001A : This indicates a hardware problem in Fabric ASIC. If the displayed error is one of the following 'Correctable Single-Bit Error in Cell Reference FIFO' 'Correctable Single-Bit Error in Reference Count Table' 'Correctable Single-Bit Error in Cell Store SRAM' The data will be corrected. The number of correctable single-bit errors occur on reading these memory is aggregated, When the aggregate count exceeds threshold (2 in 2 days), This ios msg is reported. The shelf-mgr reloads the fabric card.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_NO_LIMIT [chars]

Explanation    The fabric driver encountered the annunciated error. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-ERRRATE_EXCEED_SLOW [chars]

Explanation    The fabric driver encountered the annunciated error. Sysmgr will reload the node up to a fixed number of times the error is encountered, to recover. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-FIT_INIT_FAIL Fabric driver failed to initialize with FIT: err code([hex])

Explanation    Fabric driver cannot initialize the FIT library. User will not be able to induce errors via FIT tool.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-LINK_SHUT_DOWN_PERM Link [chars] Shutdown permanently due to [chars] .

Explanation    The Fabric driver encountered an error beyond the threshold times on the annunciated Fabric Switching Element link and the link is shutdown permanently by the driver .

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-LM_DRAIN_QUEUE_FAILURE sfe[[dec]]: Failed to Drain Queue Associated To Destination ([dec]).

Explanation    Unable to drain all the cells from a given queue. This may cause barrier timeouts once the queue is re-enabled. Hard resetting Asic'

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-RCC_HW_INIT_FAIL Fabric driver failed to initialize with RCC HW init library: err code([hex])

Explanation    Fabric driver cannot initialize with the RCC HW init library. Possible fabric multicast feature may not function correctly.

Recommended Action    Collect all the event and console logs. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-3-RCC_LIB_INIT_FAIL Fabric driver failed to initialize the RCC memory controller library: err code([hex])

Explanation    Fabric driver cannot initialize the RCC memory controller library. The node may be not be able to initialized properly.

Recommended Action    Collect all the event logs and 'sh controller fabric trace driver all location location of the node' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-4-ERR_LTRACE_INIT Fabric driver failed to initialize the ltrace - rc equals [chars]

Explanation    The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the system should still function as normal, with the exception that ltrace will not be available for sfe_drvr process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-4-ERR_LTRACE_INIT Fabric driver failed to initialize the ltrace - rc equals [chars]

Explanation    The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the system should still function as normal, with the exception that ltrace will not be available for sfe_drvr process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-4-RCC_INIT_INCOMPLETE RCC BIST on device [dec] running for [dec] seconds; ([hex])

Explanation    Fabric drivers health is contingent of the RCC library's initialization. Driver will poll to verify the status of the RCC hw init.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ABORT_FGID_WRITE Aborted FGID mcast write to [hex] as [chars] in PON reset state.

Explanation    Aborted an FGID write update because the ASIC is in the reset state. This can happen when an FGID update request is in flight when the ASIC goes through a PON reset operation as a part of an error recovery. During PON reset operation, the FGID memory refresh logic is not operational and hence the write operation is not carried through. After a PON reset recovery, the connection with the FGID server is reestablished and a full FGID download is done again. Note, that this is expected only for PON reset recovery and not hard reset.

Recommended Action    None

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_FREEZE_PRE_SCAN Freeze state of ASIC [chars] before asic scan.

Explanation    Freeze state of the ASIC before initiating ASIC scan.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_INITIALIZED Notify FSDB that [chars] is OPER_UP.

Explanation    Notify FSDB that the specified ASIC is operationally UP. This indicates that the fabric ASIC is initialized and FGID download is completed. This is expected during normal operation. On a driver restart, this message will be annunciated when the FGID download done message is received.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_INITIALIZED Fabric ASICs initialized

Explanation    This indicates Fabric ASICs are initialized and is expected during normal operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_PON_RESET_POST_SCAN Power-On reset ASIC [chars] to recover after asic scan.

Explanation    Recover identified ASIC with a power on reset following ASIC scan.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_READ_ACCESS ASIC: [chars] - read register access [hex] failed

Explanation    This indicates a failed access to the ASIC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_RESET_REASONS ASIC bit mask: Ready: [hex] Reset: [hex] Pending interrupt: [hex] Ready bits: [hex].

Explanation    This message is seen when fabric ASIC require to be reset during a driver restart. The output contains the a bit mask depiction of all ASICs on the fabric board. 'Ready' and 'Reset' masks identifies the ASICs that are in ready or reset state. If an ASIC is in reset state, pending interrupt captures additional information.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_RESET_REASONS ASIC bit mask: Ready:[hex] Reset:[hex] Halted:[hex] Not Ready:[hex] Init Fail: [hex]

Explanation    This message is seen when fabric ASIC require to be reset during a driver restart. The output contains the a bit mask depiction of all ASICs on the fabric board. 'Ready' and 'Reset' masks identifies the ASICs that are in ready or reset state. 'Halt', 'Not ready' and 'Init fail' provide additional information if the 'Reset' mask is non-zero.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ASIC_WRITE_ACCESS ASIC: [chars] - write value [hex] register access [hex] failed

Explanation    This indicates a failed access to the ASIC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-AWAIT_FGID_DOWNLOAD Await FGID download completion to notify FSDB of ASIC initialization.

Explanation    This indicates Fabric ASICs are initialized pending the FGID download done notification from FGID server. FSDB will be notified about the ASIC initialization complete state only after the ASICs are initialized and the FGID download is completed.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-BARRIER_FLOW_STARTED Barrier flow started on all ASICs

Explanation    Barriers started flowing on all the nodes/types.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-BUS_STALL_ADDR_TRACEBACK Traceback on an address [hex] detected earlier to cause bus stall interrupt.

Explanation    Certain address accesses were causing bus stall interrupts on the superstar ASIC. Such addresses are cached by the driver. Subsequently, when these addresses are accessed by the driver, this message is logged to provide a traceback information to help with debugging.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-DLL_LOAD SEA ASIC driver loaded

Explanation    Fabric driver loaded for the SEA asics.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-ERR_ASIC_ACCESS_TIMED_OUT Access to [chars] timed out. Device will be PON reset to recover.

Explanation    Sometimes, when the register access of the superstar ASIC fails, read of any of its registers returns 0xdeaddead. Now if this happens when CIH is processing an interrupt, CIH would accidentally determine the source of the interrupt as Rx Snoop SRAM SBE interrupt. In reality, this interrupt is not even enabled by the driver. The Rx snoop SRAM SBE interrupt is obtained if we traverse the interrupt tree of the superstar ASIC as given below: - Bit 0 of the top level CPU hierarchy interrupt is Rx block. - Bit 0 of the Rx block hierarchy is Rx block leaf interrupts. - Bit 0 of the Rx block leaf interrupts in Rx Snoop SRAM SBE.

Recommended Action    If this condition is noticed for every access to the ASIC, then the ASIC is possibly wedged. Resetting the ASIC or reloading the fabric card will help to recover from this condition. Driver automatically tries recovering the ASIC via PON reset. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-FIT_HARD_RESET FIT forcing hard reset of device id: [dec]

Explanation    This indicates that the FIT tool has forced/induced a hard reset.

Recommended Action    None.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-FIT_POWER_ON_RESET FIT forcing power on reset of device id: [dec]

Explanation    This indicates that the FIT tool has forced/induced a power on reset.

Recommended Action    None.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-MISSING_PLANE_CONFIG Plane config is missing or inconsistent.

Explanation    Missing admin plane configuration for this module.

Recommended Action    Check the admin plane configuration to ensure that it corresponds with the actual physical topology of the system. If this configuration looks correct then contact support, otherwise correct the configuration and the system should recover.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-6-MISSING_PLANE_CONFIG Plane config is missing or inconsistent.

Explanation    Missing admin plane configuration for this module.

Recommended Action    Check the admin plane configuration to ensure that it corresponds with the actual physical topology of the system. If this configuration looks correct then contact support, otherwise correct the configuration and the system should recover.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_BP_CFG [chars]: Error in Back pressure configuration, BP Groups : [dec], [dec], [dec]

Explanation    The Fabric driver encountered an error in back pressure configuration. This indicates BP configuration received from the fabric control software is incorrect. If this condition prevails, it could impact data traffic when fabric gets congested.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_BP_CFG [chars]: Error in Back pressure configuration, BP Groups : [dec], [dec], [dec]

Explanation    The Fabric driver encountered an error in back pressure configuration. This indicates BP configuration received from the fabric control software is incorrect. If this condition prevails, it could impact data traffic when fabric gets congested.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_DEBUG_REG Fabric driver failed to register with the debug; rc equals [chars]

Explanation    The Fabric driver was unable to register with the debug. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_DEBUG_REG Fabric driver failed to register with the debug; rc equals [chars]

Explanation    The Fabric driver was unable to register with the debug. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_INTERNAL_SW [chars]

Explanation    The Fabric driver encountered the annunciated internal SW error. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_INTERNAL_SW [chars]

Explanation    The Fabric driver encountered the annunciated internal SW error. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_LINK_TOPO A config error has occurred that may cause cell drop on [chars]. [chars]

Explanation    The upstream information received from idle cells on this link does not match with FSDB information. The topology mismatch information is a bitmap of links seeing errors. Links 0-31 is in word 0, links 32-63 in word 1, links 64-95 in word 2 and links 96-127 in word 3.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERR_LINK_TOPO Topology mismatch for [chars]

Explanation    The upstream information received from idle cells on this link does not match with FSDB information.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERRRATE_EXCEED_DEBUG [chars]

Explanation    The fabric driver encountered the annunciated error. If the displayed error is one of the following 'Multicast High Priority Acknowledge Barrier Timeout' 'Multicast Low Priority Acknowledge Barrier Timeout' 'Unicast High Priority Acknowledge Barrier Timeout' 'Unicast Low Priority Acknowledge Barrier Timeout 'Multicast High Priority Request Barrier Timeout' 'Multicast Low Priority Request Barrier Timeout' 'Unicast High Priority Request Barrier Timeout' 'Unicasts Low Priority Request Barrier Timeout' The Fabric driver and the System should still continue to function as normal. The affected link will be identified and taken offline momentarily. These errors are expected during OIR operations. If the error happens during steady state, investigation should be done for other unexpected oir events. If there is no other unexpected oir or anything, and the issue happened 2 in 2 days, then some effort should be done to identify the source link.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-ERRRATE_EXCEED_DEBUG [chars]

Explanation    The fabric driver encountered the annunciated error. The Fabric driver and the System should still continue to function as normal.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-LINK_SHUT_DOWN Fabric Link: [chars] - Shutdown: [chars]

Explanation    The Fabric driver encountered an error on the annunciated Fabric Switching Element link and the link is brought down.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_DRVR-7-LINK_SHUT_DOWN Fabric Link: [chars] - Shutdown: [chars]

Explanation    The Fabric driver encountered an error on the annunciated Fabric Switching Element link and the link is brought down.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FABRIC_SRVR Messages

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-1-ERR_WRONG_CHASSIS [chars]

Explanation    MINIQ Version 2 chassis type do not support sea/superstar based fabric cards. MINIQ Version 1 chassis type do not support superstar based fabric cards. This is because of unsupported backplane in these chassis.

Recommended Action    Replace the chassis.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-2-ERR_SHUTDOWN Failed to shutdown by shelf-mgr. error code([hex])

Explanation    Fabric driver encountered a system error in bringing down the node through shelfmgr. The card and its fabric ASICs should have been isolated from the system before the shutdown attempt.

Recommended Action    Check the health of the shelfmgr process on the dSC RP. If shelfmgr is healthy, and the card cannot self reload, then reload the card with the following command in admin mode: 'hw shut loc y/SMx/sp', where x is the SM module number that generated the error, y is the rack that it is in. If manual shutdown does not work, or if the error recurs, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_ANNOUNCE EES announcement failed, rc equals [chars]

Explanation    EES domain enabling failed. This will prevent ucd/mcd messages to be exchanged between the applications and driver.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_BOARD_NOT_POWERED Waiting for fabric mother board to be powered up...

Explanation    Fabric card is not powered up yet. So, continue to wait.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_DRV_INIT Initialization of fabric driver failed: [chars] ; exiting...

Explanation    Fabric driver encountered the annunciated error during the driver initialization. The System Manager process (sysmgr) will automatically respawn the (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_EES_REG EES registration failed, rc equals [chars]

Explanation    EES domain enabling failed. This will prevent ucd/mcd messages to be exchanged between the applications and driver.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_ENABLE [chars] failed for [dec], rc equals [chars]

Explanation    The driver failed to enable/disable inter-process communication with fgid_server. This will prevent ucd/mcd messages to be exchanged between fgid_server and driver.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_EVM_CREATE Failed to create event manager for '[chars]'

Explanation    The Fabric driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_FGID_CONS_THREAD Process sfe_drvr will be restarted. Asic status(oper_up/avl_map) equals [hex]/[hex]. Cfg availability (topo/oob/bpe) equals [hex]/[hex]/[hex].

Explanation    This is an error message and is seen in the abnormal condition when the fgid consumer thread fails to start successfully. Fgid consumer thread will successfully start if all the asics are operationally up. If the asics do not report oper-up within the timeout period fgid_consumer thread cannot be started. As a consequence SFE Driver is restarted. avl_map is a bitmap representing all the asics that are required to be operationally up to successfully start the fgid consumer thread. The oper_up bitmap indicates the asics that are currently operationally up. The topo/oob/bpe information indicates which of the asics have received the specific (topo/oob/bpe) configuration.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-ERR_FGID_DOWNLOAD_FAILED Initial FGID Download failed (after total delay of [dec] secs)

Explanation    The message is seen when initial FGID download from the FGID server to SFE driver does not get completed even after multiple attempts to reset the EES connection. This means the communication between SFE driver and FGID driver is broken and indicates a EES transport issue.

Recommended Action    Capture the output of the CLIs as specified in required_info and contact your Cisco technical support representative. Once the required information is captured, a restart of sfe_drvr process on the affected fabric card, followed by a restart of fgid_server process on the appropriate RP/DRP can be attempted to recover from this error.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-3-RESET_ALL_ASICS FDI request to reset all the ASICs on the fabric board.

Explanation    Process a request received from FSDB to reset all the ASICs on the fabric card.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-4-ERR_ECM_CREATE Failed to create Event Connection Manager : [chars]

Explanation    The Fabric driver was unable to create an event connection manager for EDM. Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-4-ERR_ECM_NOTIFY Failed to register with ECM to receive notifications : [chars]

Explanation    The Fabric driver was unable register with ECM to receive notifications when the connection to Sysdb goes down/up/closed. Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-4-ERR_FGID_DOWNLOAD Initial FGID Download did not complete within timeout period ([dec] secs). Retrying.

Explanation    The message is seen when initial FGID download from the FGID server to SFE driver does not get completed. Generally this indicates a transient EES transport issue. The SFE driver will try to recover from this error by resetting the EES connection to FGID server.

Recommended Action    There is no specific manual intervention needed to be taken by the customer for this message. As mentioned in the explanation, SFE driver will try to recover from this situation on its own. However, if this message is being seen often, then please capture the output of the CLIs mentioned in the required_info, and contact Cisco technical support representative.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-4-ERR_LTRACE_INIT Fabric driver failed to initialize the ltrace - rc equals [chars]

Explanation    The Fabric driver could not open/initialize the ltrace buffer. The Fabric driver and the system should still function as normal, with the exception that ltrace will not be available for sfe_drvr process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-6-ASIC_RESET_REASONS Asics being reset, Respawn Count equals [dec] Checkpoint status equals [dec] Interrupt Status equals [hex] ASICs are ready equals [dec]

Explanation    This message is seen when fabric ASICS are being reset. The status reported here provide information about the reason for the reset.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-6-FAB_MODULE [chars]

Explanation    This is to give information regarding fabric module type.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-6-FABRIC_DISCOVERY Discovered [chars] fabric

Explanation    This is to give information regarding fabric card type.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-6-INVALID_CARD_TYPE_ERROR Cannot find board revision

Explanation    The message is seen when we fail to read the EEPROM for board revision. Check platform libraries & i2c bus connectivity.

Recommended Action    Check the EEPROM programming, environmental condition and the type of board that is inserted.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_BAG_REG [chars]

Explanation    The Fabric driver was unable to register Fabric driver bags. The Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_DEBUG_INIT Fabric driver failed to initialize the debug; rc equals [chars]

Explanation    The Fabric driver was unable to initialize debug. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_DEBUG_REG Fabric driver failed to register with the debug; rc equals [chars]

Explanation    The Fabric driver was unable to register with the debug. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_INTERNAL_SW [chars]

Explanation    The Fabric driver encountered the annunciated internal SW error. The System Manager process (sysmgr) will automatically respawn this (sfe_drvr) process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_PCDS_SUPPORT [chars]

Explanation    PCDS support will not be available due to the specified reason.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRIC_SRVR-7-ERR_SYSDB_EDM_REG [chars]

Explanation    The Fabric driver was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried. The Fabric driver and the System should continue to function as normal, with the exception that the 'show' commands for Fabric driver will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FABRICQ_MGR Messages

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-3-ERR_FBP_CFG Fabricq received an invalid FBP config. [chars]

Explanation    The Fabricq received an invalid FBP configuration

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-3-ERR_INIT Initialization Error: [chars] Reason: [chars]. Exiting.

Explanation    Fabricq manager encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the fabricq_mgr driver is up and running by executing the following command at the CLI of the active RP: 'show process fabricq_mgr location ' If it is still non-operational, enable the following debugs of the fabricq_mgr driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart fabricq_mgr location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    Fabricq encountered a fatal memory allocation error. Please contact TAC support.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-4-ERR_CHKPT_INIT Checkpoint Initialization failed. Reason: [chars]

Explanation    Fabricq Checkpoint Init error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_BAG_REG Bag register failed for rules. Reason: [chars]

Explanation    EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_CLIENT_REG Client [chars] failed. Reason: [chars]

Explanation    Fabricq Manager client Registration/Unregistration error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_DLL_INIT Dll Initialization for [chars] failed. Reason: [chars]

Explanation    Fabricq driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_EVM_CREATE Event Manager create failed for [chars]. Reason: [chars]

Explanation    Fabricq Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]. Reason: [chars]

Explanation    Fabricq Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed. Reason: [chars]

Explanation    Fabricq Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_LWM_REPLY An error occurred during LWM message reply. Reason: [chars]

Explanation    Fabricq LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ_MGR-7-ERR_SYSDB_EDM_REG Sysdb Register EDM failed. Reason: [chars]

Explanation    Fabricq Sysdb Register EDM error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FABRICQ Messages

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-ERR_ASIC_ERROR Fabricq [dec]: [chars]

Explanation    Fabricq encountered an ASIC error which software cannot resolve

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-ERR_ASIC_GENERIC Fabric Asic [dec] encountered generic error(s). Details: [chars]

Explanation    Fabricq encountered an interrupt that has exceeded its threshold value. Software takes appropriate action to log and fix the error.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-ERR_ASIC_INIT fabricq asic [dec]: encountered [chars] during init: [chars]

Explanation    Fabricq Asic driver encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-ERR_HW_DLL Fabricq [dec]: [chars] : [chars]

Explanation    Fabricq encountered an internal hardware dll api error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-ERR_SW_DLL Fabricq [dec]: [chars] : [chars]

Explanation    Fabricq encountered an internal software dll api error Following are some of the reasons for this internal error: 1) mutext init 2) thread creation.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-FFI_LINK_BRINGDOWN Fabric link [dec] on ASIC [dec] is brought down due to too many [chars] errors

Explanation    A fabric link was brought down due to too many errors.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-1-IO_ERROR Fabricq [dec]: [chars]

Explanation    Fabricq encountered an IO error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_ASIC_FCRAM_ASSERT Assert error in Fabricq ASIC [dec]. FCRAM Channel [dec].

Explanation    Fabricq ASIC encountered a FCRAM Channel error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_ASIC_FCRAM_ASSERT Assert error in Fabricq ASIC [dec]. FCRAM Channel [dec].

Explanation    Fabricq ASIC encountered a FCRAM Channel error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_BIST Error during [chars] BIST

Explanation    Built-In Self-Test failed for Fabricq ASIC.

Recommended Action    Collect output of 'show logging', run offline diagnostics on the card and contact TAC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_BIST Error during [chars] BIST

Explanation    Fabricq BIST error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_DMA [chars]

Explanation    An error occurred while a DMA transfer initiated by the FQM process was taking place. This means certain data requested by the FQM process will not be available.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_INIT Instance: [dec]. Error: [chars]

Explanation    Fabricq Asic driver encountered a fatal error resulting in the restart of the fabricq_mgr driver process.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the fabricq_mgr driver is up and running by executing the following command at the CLI of the active RP: 'show process fabricq_mgr location ' If it is still non-operational, enable the following debugs of the fabricq_mgr driver process: error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events and restart the driver by executing the following command at the CLI of the active RP: 'process restart fabricq_mgr location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_NULL_INPUT_ARGS [chars]

Explanation    Fabricq asic dll encountered an internal software API error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-ERR_RX_FBP Fabricq ASIC received incorrect FBP bitmap. [chars]

Explanation    The Fabricq ASIC is configured to expect fabric backpressure information for a particular set of groups on a small set of links. This error indicates that incoming backpressure information doesn't match the expected config.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-PCL_CCNT_ERR Major error in PCL of fabricq asic [dec]: [chars] data.

Explanation    Sponge encountered a PCL cell count mismatch error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-PCL_CSLOT_SYNC Major internal error in PCL of fabricq asic [dec]: [chars].

Explanation    Sponge encountered a PCL internal error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-PCL_PKT Minor error in PCL of fabricq asic [dec]. [chars]

Explanation    Sponge encountered a PCL Packet error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-PCL_XCELL_ERR Major error in PCL of fabricq asic [dec]: [chars]

Explanation    Sponge encountered a PCL extra cell error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-RESET Resetting Fabricq ASIC Device [dec]. Reason: [chars]

Explanation    Resetting Fabricq ASIC on detecting fatal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-3-RESET Resetting Fabricq ASIC Device [dec]. Reason: [chars]

Explanation    The fabricq ASIC is reset due to the reason displayed in the message. Most often the situation recovers after ASIC reset. If the resets persists, contact technical support with the following information.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-ERR_ASIC_MBE Fabricq Asic [dec] detected multibit error(s). Details: [chars]

Explanation    Fabricq Asic encountered a memory uncorrectable error

Recommended Action    The multi-bit errors can happen in one of many blocks of the fabricq ASIC. One of them is the Fabric Interface (FI). If these error messages are generated for short intervals for FI links when a fabric card is disabled / reloaded / OIR'ed, then they are harmless. If these messages continue for more than 2 minutes, with incrementing uncorrectable error (UCE) counters, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-ERR_ASIC_PARITY Fabricq Asic [dec] detected parity error(s). Details: [chars]

Explanation    Fabricq Asic encountered a parity error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-ERR_ASIC_SN_LINK Fabricq ASIC [dec] encountered a CpuCtrl [chars] error

Explanation    Fabricq ASIC encountered a CpuCtrl CRC/Sync error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-FFI_LINK_ALARM Link Alarm on Fabricq ASIC [dec] link [dec]

Explanation    Fabricq ASIC encountered a link alarm

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-FFI_TOPOLOGY Fabric topology inconsistency detected for ASIC [unsigned int] link [unsigned int] (observed topology information: [hex], expected: [hex])

Explanation    An inconsistency between the expected and observed topologies of the fabric was detected.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-FI_LINK_ALARM Link Alarm on Fabricq ASIC [dec] link [dec]

Explanation    Fabricq ASIC encountered a link alarm

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-FI_LINK_BRINGDOWN Fabric link [dec] on ASIC [dec] may be brought down due to too many errors

Explanation    A fabric link was brought down due to too many UCE or parity errors.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-FI_TOPOLOGY Fabric topology inconsistency detected for ASIC [unsigned int] link [unsigned int] (observed topology information: [hex], expected: [hex])

Explanation    An inconsistency between the expected and observed topologies of the fabric was detected.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-MI_WEDGE Major error in Fabricq ASIC [dec]. MI [chars] Wedged

Explanation    Fabricq ASIC encountered a MI Unicast/Multicast Wedge error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-4-PSN_WRAP Major error in PCL of Fabricq asic [dec]: [chars] . [hex] spo_pcl_mem_ppbr [hex][hex]%08x[hex]%08x[hex]%08x[hex]

Explanation    Fabricq encountered a PCL Packet Sequence Wrap error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-5-ERR_RES_PROG Error during Resource Programming [chars] [unsigned int] Reason: [chars]

Explanation    An error occurred while the Fabricq driver was trying to create queues for an interface. This may leave one or more interfaces out of operation.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-5-ERR_RES_PROG Error during Resource Programming [chars] [unsigned int] Reason: [chars]

Explanation    An error occurred while the Fabricq driver was trying to create queues for an interface. This may leave one or more interfaces out of operation.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-5-MI_BPDECODE Major error in Fabricq ASIC [dec]. MI [chars] Backpressure decode error

Explanation    Fabricq ASIC encountered a MI Unicast/Multicast BP Decode error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_EOP Minor error in Fabricq ASIC [dec]. [chars] End of Packet error

Explanation    Fabricq ASIC encountered a Unicast/Multicast Unexpected/Missing End Of Packet error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_EOP Minor error in Fabricq ASIC [dec]. [chars] End of Packet error

Explanation    Fabricq ASIC encountered a Unicast/Multicast Unexpected/Missing End Of Packet error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_GENERIC Fabric Asic [dec] encountered generic error(s). Details: [chars]

Explanation    Fabricq encountered an interrupt that has exceeded its threshold value. Software takes appropriate action to log and fix the error.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_OOR Fabricq Asic [dec] encountered [chars] Out Of Resources error.

Explanation    Fabricq encountered an out of resources error.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_RESET_DEFERRAL Fabricq ASIC [dec] : [chars]

Explanation    The annunciated error occurred relating to asic deferral.

Recommended Action    In one of the persistent storage devices (harddisk:/, disk0: etc.) on the DSC's RP that was active at the time the message was emitted, a file may have been created under a directory called asic_snapshots/ for this occurrence. The name is of the format 'sponge_debug_snapshot.noderack_slog_CPU0.[first/latest]' Collect that file if present and save it to the case.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-ERR_ASIC_SBE Fabricq Asic [dec] detected single bit error(s). Details: [chars]

Explanation    Fabricq Asic encountered a memory correctable error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-SIF_FBP Minor error: Cluster: [dec] in Fabricq ASIC [dec] has SIF FBP [chars] error

Explanation    The Fabricq asic encountered a fabric backpressure error. These sort of errors are to be expected during bootup or during OIR events, and are harmless for the vast majority of the time. The only time they would signify a serious error is if they recur for long periods.

Recommended Action    If these messages are recurring and/or you're seeing other faults (such as traffic loss) then contact your support agent.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-SPI_FBP Minor error: Cluster: [dec] in Fabricq ASIC [dec] has SPI FBP [chars] error

Explanation    The Fabricq asic encountered a fabric backpressure error. These sort of errors are to be expected during bootup or during OIR events, and are harmless for the vast majority of the time. The only time they would signify a serious error is if they recur for long periods.

Recommended Action    If these messages are recurring and/or you're seeing other faults (such as traffic loss) then contact your support agent.

Error Message     
 
    
    
   

%FABRIC-FABRICQ-6-URG_CTX Minor error in PCL of Fabricq asic [dec]. Urgent Context exceeded 5 equals [hex]

Explanation    Fabricq encountered a PCL Urgent Context error

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%FABRIC-FABRICQ-7-ERR_DMA Error during DMA transfer: Source Addr [hex], Dest Addr [pointer]. Reason: [chars]

Explanation    An error occurred while a DMA transfer initiated by the FQM process was taking place. This means certain data requested by the FQM process will not be available.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FDI Messages

Error Message     
 
    
    
   

%FABRIC-FDI-2-ERR_CONNECTION [chars]; Conn_id equals [dec] Conn_name equals [chars]

Explanation    The FDI library encountered the annunciated connection error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-2-ERR_INTERNAL_SW [chars] ; rc equals [chars]

Explanation    The FDI encountered the annunciated internal sw error.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FDI-2-ERR_MSG_TYPE FDI received incorrect message type - [dec] from mid ([dec]:[dec]:[dec])

Explanation    FDI received incorrect message type and failed to process the message. The System Manager process (sysmgr) will automatically respawn the process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-3-EES_ANNOUNCEMENT_ERR EES Announcement Failed: [chars]

Explanation    This process encountered an internal software error. [chars] provide detailed information about this error Process will restart to recover from this error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-3-ERR_BUFF_Q FDI Buffers are full; Conn_id [dec]. Data_Size [dec]. Buffer_states ([dec] [dec])

Explanation    FDI buffers are full and FDI can't buffer any more messages. Buffer will fill up for 2 main reasons: 1. Receiver is blocked and not able to return ack 2. Some kind of transport problem In such cases, FDI would flap the connection and flush the buffers hoping that conditions 1 or 2 were transient.

Recommended Action    Examine the state of GSP on the node of the FDI application. Collect gsp stats for the sender and receiver application. Also determine if receiver application was ever blocked during the time buffer went full. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-3-ERR_CORRUPT_MSG Possible Corrupt Msg Returned By GSP Case ([chars])

Explanation    --

Recommended Action    Examine the state of GSP on the node of the FDI application. Collect gsp stats for the sender and receiver application. Also determine if receiver application was ever blocked during the time buffer went full. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-3-ERR_SEND_FAIL Unable to send message to peer [dec]-[hex]-[dec]: [chars]

Explanation    An unexpected error occurred while sending an message. Process will restart to recover from this error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_COMM_SYSTEM_ERROR IPC non blocking communication failed to group id: [dec], tag [hex] - id [dec], seq [dec], status [dec]: [chars]

Explanation    The FDI Library uses gsp_group_memberset_nb ( non blocking api ). Any errors are communicated back via a callback. These errors are considered bad, since it is likely a member did not receive a message. These errors returned are communicated via this msg. This may indicate some transport issue.

Recommended Action    Restart application may be required, if messages continued to be logged.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_DEBUG_CLEAN FDI library failed to cleanup FDI debug info in debug infrastructure ; rc equals [chars]

Explanation    The FDI library was unable to cleanup FDI debug info in debug infrastructure. The System should still continue to function as normal.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_DEBUG_INIT FDI library failed to initialize debug for fdi - [chars]; rc equals [chars]

Explanation    The FDI library was unable to initialize debug. The FDI component and the System should still continue to function as normal, with the exception that the debugs will not be available for FDI.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_DEBUG_REG FDI library failed to register with debug infrastructure ; rc equals [chars]

Explanation    The FDI library was unable to register with debug infrastructure. The FDI component and the System should still continue to function as normal, with the exception that the debugs will not be available for FDI.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_EDM_INIT [chars]; rc equals [chars]

Explanation    The FDI Library encountered the annunciated EDM Initialization error. The System should still continue to function as normal, with the exception that the 'show' commands for FDI will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_GROUP_MEMBER_ALREADY_EXISTS Group ([dec]) Member ([dec]:[dec]:[dec]) already exsts overriding with latest member info([dec]:[dec]:[dec]).

Explanation    A member is attempting to be added to a group with an entry already present. The member likely did not get cleaned up correctly. Assumed latest member info is correct, and override existing entry.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_MEM_ALLOC FDI failed to allocate [dec] bytes

Explanation    The FDI was unable to allocate memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_MEMBER_ALREADY_EXISTS Member [chars] entry already exists and registered. Updating with new member info.

Explanation    The FDI Library has received a new member notification for a member that already exists in the FDI db, and registered. Possible that we failed to cleanup old member, or a delayed new member msg. There should be no system impact as FDI will just update with the latest info.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FDI-7-ERR_MSG_SEQ_GT Out of sequence (greater than) message received from [chars] [chars] reset connection.

Explanation    The FDI Library encountered an internal error with a message received. Since one message is active at one time, the message received should be the next expected seqnum. This may indicate system resource issue, or a period where system is heavily loaded. If message persists, application may need to be restarted.

Recommended Action    Restart application may be required, if messages continued to be logged.

FEATURE_LPTS Messages

Error Message     
 
    
    
   

%FABRIC-FEATURE_LPTS-3-ERR_DOUBLE_FREE Double free of FGID [dec]

Explanation    A software error occurred, when the PA attempted to double free the FGID

Recommended Action    No action required Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FEATURE_LPTS-3-ERR_FGID_DB_RETRIES_EXCEEDED Number of unknown errors from FGID-DB ([dec]) has exceeded maximum

Explanation    A software error occurred, when the PA attempted to allocate FGID's from the FGID aggregator.

Recommended Action    The process will attempt to recover by restarting. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FEATURE_LPTS-3-ERR_UNALLOCATED_FREE Attempt to free unallocated FGID [dec]

Explanation    A software error occurred, when the PA attempted to free unknown FGID

Recommended Action    No action required Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FEATURE_LPTS-3-ERR_UNKNOWN_FGID_DB_ERROR Unknown error from FGID-DB, [chars] FGID [dec] [[dec]]([dec], [dec]): [chars]

Explanation    A software error occurred, when the PA attempted to Allocate, free or join FGID from the FGID Aggregator.

Recommended Action    The process will attempt to recover by retrying the operation. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FGID_AGG Messages

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_DEBUG_INIT fgid_aggregator unable to initialize dbg ; rc equals [chars]

Explanation    The FGID Aggregator was unable to initialize debug. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_EVM_CREATE FGID Aggregator failed to create [chars] evm ; rc equals [chars]

Explanation    The FGID aggregator was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_EVM_SYNC_ATTACH FGID Aggregator failed to attach [chars] to evm ; rc equals [chars]

Explanation    The FGID Aggregator was unable to attach the indicated event handler to the event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_GSP [chars]: rc equals [chars]

Explanation    The FGID Aggregator was unable to create/join GSP group. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_INTERNAL_SW [chars]; [chars]

Explanation    The FGID Aggregator encountered the annunciated SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_MEM_ALLOC FGID Aggregator unable to allocate [dec] bytes

Explanation    The FGID Aggregator was unable to allocate memory. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-3-ERR_SYSMGR [chars]; rc equals [chars]

Explanation    The FGID Aggregator encountered the annunciated sysmgr error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_AGG-7-ERR_LTRACE_INIT FGID Aggregator failed to initialize the ltrace file [chars] : [chars]

Explanation    The FGID Aggregator Could not open the annunciated ltrace buffer. The FGID component and the system should still function as normal, with the exception that ltrace will not be available for fgid_aggregator process.

Recommended Action    No action is required.

FGID_ALLOC Messages

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-3-ERR_EVM_CREATE FGID Allocator failed to create [chars] evm; rc equals [chars]

Explanation    The FGID allocator was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-3-ERR_GSP [chars]: rc equals [chars]

Explanation    The FGID Allocator encountered the annunciated GSP error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-3-ERR_INTERNAL_SW [chars] ; rc equals [chars]

Explanation    The FGID Allocator encountered the annunciated internal SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-3-ERR_MEM_ALLOC FGID Allocator failed to allocate [dec] bytes

Explanation    The FGID Allocator was unable to allocate memory. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-3-ERR_SYSMGR [chars]; rc equals [chars]

Explanation    The FGID Allocator encountered the annunciated sysmgr error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_BAG_REG FGID allocator failed to register FGID bags; rc equals [chars]

Explanation    The FGID allocator was unable to register FGID bags. The FGID component and the System should continue to function as normal, with the exception that the 'show' commands for FGID allocator will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_CHKPT_INIT FGID Allocator failed to initialize the checkpoint library ; rc equals [chars]

Explanation    The FGID Allocator was unable to initialize the checkpoint library. The fgid_allocator process may need restarting, if the errors persist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_CHKPT_ITERATE_START FGID Allocator failed to start to iterate Checkpoint table [chars]; rc equals [chars]

Explanation    The FGID Allocator was unable to start to iterate checkpoint table. The fgid_allocator process may need restarting, if the errors persist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_CHKPT_REG FGID Allocator failed to register the Checkpoint table [chars] ; rc equals [chars]

Explanation    The FGID Allocator was unable to register the checkpoint table. The fgid_allocator process may need restarting, if the errors persist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_DEBUG_INIT FGID Allocator failed to initialize debug ; rc equals [chars]

Explanation    The FGID Allocator failed to initialize debug. The FGID component and the System should still continue to function as normal, with the exception that the debugs will not be available fgid_allocator process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_LTRACE_INIT FGID Allocator failed to initialize the ltrace file [chars]; rc equals [chars]

Explanation    The FGID Allocator could not open the annunciated ltrace buffer. The FGID component and the system should function as normal, with the exception that ltrace will not be available for fgid_aggregator process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_SYSDB_BIND FGID Allocator failed to bind to Sysdb name space [chars]; rc equals [chars]

Explanation    The FGID-DB allocator unable to bind to sysdb name space. The fgid_allocator may need restarting if the errors persist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_ALLOC-7-ERR_SYSDB_EDM_REG FGID allocator failed to perform EDM registration; rc equals [chars]

Explanation    The FGID allocator was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried. The FGID component and the System should continue to function as normal, with the exception that the 'show' commands for FGID allocator will not be available.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FGID_BCDL_CONSUMER Messages

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BCDL [chars] ; rc equals [chars]

Explanation    The BCDL Consumer process has encountered the annunciated BCDL error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_BOARD_TYPE FGID BCDL Consumer failed to get hardware board type: rc equals [chars]

Explanation    The FGID BCDL Consumer was unable to get the board type.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_DEBUG_INIT The FGID BCDL Consumer Failed to initialize debug; rc equals [chars]

Explanation    The FGID BCDL Consumer was unable to initialize debug. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_EVM [chars] : [chars]

Explanation    The FGID BCDL consumer encountered the annunciated Event Manager Error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FDI_CLIENT_REG Unable to perform FDI client registration; rc equals [chars]

Explanation    The FGID BCDL Consumer was unable to register with the FDI client. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_DOWNLOAD_DONE_NOTIF FGID BCDL Consumer failed to notify SFE driver about FGID download complete; rc equals [chars]

Explanation    The FGID BCDL Consumer encountered an error while notifying the SFE driver about FGID download completion. This indicates a problem with communication between SFE_DRVR and FGID BCDL consumer. Restart SFE driver manually.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_FGID_SET FGID BCDL Consumer failed to set FGID [chars] bitmap; rc equals [chars]

Explanation    The FGID BCDL Consumer encountered an error while setting S2 or S3 bitmap. This indicates a problem with the communication between the SFE driver and the FGID BCDL consumer. The FGID BCDL consumer and/or SEA driver may need restarting if the errors persist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-3-ERR_RACK_NUM FGID BCDL Consumer failed to get the rack value; rc equals [chars]

Explanation    The FGID BCDL Consumer encountered an error while retrieving the rack value from nodeid. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_BCDL_CONSUMER-7-ERR_LTRACE_INIT FGID BCDL Consumer failed to initialize the ltrace file [chars] : rc equals [chars]

Explanation    The FGID BCDL Consumer could not open the annunciated ltrace buffer. The FGID component and the system should function as normal, with the exception that ltrace will not be available for FGID BCDL Consumer process.

Recommended Action    No action is required.

FGID_LIB Messages

Error Message     
 
    
    
   

%FABRIC-FGID_LIB-7-ERR_DEBUG_INIT FGID library failed to initialize the debug ; rc equals [chars].

Explanation    The FGID library failed to initialize debug. The FGID component and the system should still function as normal, with the exception that the debugs will not be available for FGID library.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_LIB-7-ERR_LTRACE_INIT FGID library failed to initialize the ltrace ; rc equals [chars].

Explanation    The FGID library failed to initialize ltrace. The FGID component and the system should still function as normal, with the exception that the ltrace will not be available for FGID library.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FGID_SVR Messages

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-2-ERR_EES_INIT Rack num could not be determined, rc equals [chars]

Explanation    Rack num could not be determined because platform_get_my_nodeid failed.

Recommended Action    Whenever this happens, fgid_server will dump a core file. No action is required.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_BCDL [chars]; rc equals [chars]

Explanation    The FGID Server encountered the annunciated BCDL error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_DSC Failed to register for DSC notification; rc equals [chars]

Explanation    The FGID Server encountered DSC error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_EES [chars], rc equals [chars]

Explanation    Issue with EES

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_EVM_CREATE FGID Server failed to create [chars] evm; rc equals [chars]

Explanation    The FGID Server was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_EVM_SYNC_ATTACH FGID Server failed to attach [chars] evm; rc equals [chars]

Explanation    The FGID Server was unable to attach the indicated event handler to the event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_GSP [chars] ; rc equals [chars]

Explanation    The FGID-DB server encountered the annunciated GSP error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_INTERNAL_SW [chars]; [chars]

Explanation    The FGID Server encountered the annunciated SW error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_MEM_ALLOC FGID Server unable to allocate [dec] bytes

Explanation    The FGID Server was unable to allocate memory. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-3-ERR_USAGE FGID Server : Server Id requested [chars] is not a allowed server_id

Explanation    Incorrect command line parameters were passed to the FGID Server, and so it failed to start.

Recommended Action    Check the startup arguments passed to FGID-DB. A default configuration will be used if no parameters are passed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-4-WARNING_INTERNAL_SW [chars]; [chars]

Explanation    The FGID Server encountered the annunciated SW error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-7-ERR_LTRACE_INIT FGID Server failed to initialize the ltrace file [chars]; rc equals [chars]

Explanation    The FGID Server Could not open the annunciated ltrace buffer. The FGID component and the system should function as normal, with the exception that ltrace will not be available for fgid_server process.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FGID_SVR-7-ERR_SYSMGR [chars] ; rc equals [chars]

Explanation    The FGID-DB server failed in sysmgr API

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FIA_API Messages

Error Message     
 
    
    
   

%FABRIC-FIA_API-7-ERR_ECM Event Connection Manager (ECM) Error: [chars] : [chars]

Explanation    The FIA driver client library encountered the annunciated error condition. There are 3 types of this failure. - ECM create failure: In this case the FIA driver client library will not be able to connect to the FIA driver. - Register notification handler failure: In this case the FIA driver client library will not receive notification of ECM events. - Failure to open a connection:

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FIA Messages

Error Message     
 
    
    
   

%FABRIC-FIA-0-ASIC_FATAL_FAULT Fabric interface asic ASIC[dec] encountered fatal fault [hex] - [chars]

Explanation    Fabric Interface Asic encountered an internal fatal fault. Card reload is the only way to recover from this error. The format string would display which of the internal fatal error resulted in this alarm.

Recommended Action    The board would get reloaded. On reload of board, run following commands from RSP ksh to decode PCDS information - pcds_decode -c FIA .pcds file pcds_decode -c PFM_NODE .pcds file. If users has auto reset option disabled in admin config, then the board would not get reloaded on its own. At this stage collect the output of 'show asic-errors fia inst all location loc'.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_0 Arbitration Serdes Link 0 Failure on FIA 0

Explanation    Arbitration serdes link 0 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_1 Arbitration Serdes Link 0 Failure on FIA 1

Explanation    Arbitration serdes link 0 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_0 Arbitration Serdes Link 1 Failure on FIA 0

Explanation    Arbitration serdes link 1 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_1 Arbitration Serdes Link 1 Failure on FIA 1

Explanation    Arbitration serdes link 1 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ASIC_INIT_ERR_0 Crossbar fabric interface ASIC-0 init error

Explanation    Crossbar fabric interface ASIC-0 failed during init.

Recommended Action    Reboot the board. If the error persists, contact TAC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-ASIC_INIT_ERR_1 Crossbar fabric interface ASIC-1 init error

Explanation    Crossbar fabric interface ASIC-1 failed during init.

Recommended Action    Reboot the board. If the error persists, contact TAC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_0 Data Serdes Link 0 Failure on FIA 0

Explanation    Data serdes link 0 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_1 Data Serdes Link 0 Failure on FIA 1

Explanation    Data serdes link 0 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_0 Data Serdes Link 1 Failure on FIA 0

Explanation    Data serdes link 1 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_1 Data Serdes Link 1 Failure on FIA 1

Explanation    Data serdes link 1 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_0 Data Serdes Link 2 Failure on FIA 0

Explanation    Data serdes link 2 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_1 Data Serdes Link 2 Failure on FIA 1

Explanation    Data serdes link 2 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_0 Data Serdes Link 3 Failure on FIA 0

Explanation    Data serdes link 3 failure on FIA 0.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_1 Data Serdes Link 3 Failure on FIA 1

Explanation    Data serdes link 3 failure on FIA 1.

Recommended Action    Wait a few minutes. If it doesn't recover, please reload the board using command 'reload location '. Make sure board is seated properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-PKT_INT_ERR_AT_DDRIF_0_0 Pkt Integrity Error at DDR interface from Punt/Bridge-0 FPGA on FIA 0

Explanation    Packet Integrity Error at DDR interface from Punt/Bridge-0 FPGA on FIA 0.

Recommended Action    Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-PKT_INT_ERR_AT_DDRIF_0_1 Pkt Integrity Error at DDR interface from Punt/Bridge-0 FPGA on FIA 1

Explanation    Packet Integrity Error at DDR interface from Punt/Bridge-0 FPGA on FIA 0.

Recommended Action    Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-PKT_INT_ERR_AT_DDRIF_1_0 Pkt Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA 0

Explanation    Packet Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA 0.

Recommended Action    Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-PKT_INT_ERR_AT_DDRIF_1_1 Pkt Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA 1

Explanation    Packet Integrity Error at DDR interface from Punt/Bridge-1 FPGA on FIA 1.

Recommended Action    Verify correct version of Punt/Bridge FPGA is loaded. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-SUSTAINED_CRC_ERR Fabric interface ASIC-[dec] has sustained CRC errors

Explanation    Fabric interface ASIC is reporting a sustained rate of CRC errors.

Recommended Action    Check for other failures like online diags. Reload the board to see if the error goes away. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-TEMP_TOO_HIGH_0 Crossbar fabric interface ASIC-0 temperature is too high

Explanation    Crossbar fabric interface ASIC-0 is reporting a very high temperature.

Recommended Action    Check if board is reporting temperature alarm. If not, it is due to Crossbar fabric interface heatsink not being installed properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-1-TEMP_TOO_HIGH_1 Crossbar fabric interface ASIC-1 temperature is too high

Explanation    Crossbar fabric interface ASIC-1 is reporting a very high temperature.

Recommended Action    Check if board is reporting temperature alarm. If not, it is due to Crossbar fabric interface heatsink not being installed properly. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-2-ERR_MUTEX_LOCK Driver failed to lock mutex to access qlink register. rc([hex]) [chars]

Explanation    The FIA driver cannot access the qlink register due to mutex lock failure.

Recommended Action    This is a fatal error as the fia_driver process cannot configure the qlink ASIC on ASIC/channel errors or enabling the channels.

Error Message     
 
    
    
   

%FABRIC-FIA-2-ERR_MUTEX_UNLOCK Driver failed to unlock mutex to after accessing qlink. rc([hex]) [chars]

Explanation    The FIA driver cannot unlock the mutex after accessing the qlink.

Recommended Action    This is a fatal error as the fia_driver process cannot configure the qlink ASIC on ASIC/channel errors or enabling the channels if the mutex is not working.

Error Message     
 
    
    
   

%FABRIC-FIA-2-FIAHW_INT_FIFO [chars] [chars] ([hex])

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait atleast 3 minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-2-FIAHW_INT_PARITY [chars] [chars] ([hex])

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait atleast 3 minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-CPP_ERR [chars]:[dec] [chars] - [chars]

Explanation    FIA and CPP SPI interface error

Recommended Action    Report the error

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_BRIDGE Initialization Error: FIA-driver failed to create Bridge interface. Exiting

Explanation    FIA driver could not create Bridge instance.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_BRIDGE_EVM Initialization Error: Bridge-driver failed to create Event Manager. Exiting

Explanation    Fabric Bridge driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_BRIDGE_INIT Initialization Error: Bridge-driver failed to initialize [chars]. Reason: [chars]. Exiting

Explanation    Fabric Bridge driver subsystem initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_BRIDGE_OS Initialization Error: Bridge-driver failed to invoke OS [chars] service. Exiting

Explanation    Fabric Bridge driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_CLIENT_EVM Initialization Error: FIA-driver client failed to create Event Manager. Exiting.

Explanation    FIA-driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_CLIENT_INIT Initialization Error: FIA-driver client failed to initialize [chars]. . Exiting

Explanation    Fabric driver subsystem initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_ECM_CREATE Failed to create Event Connection Manager[[chars]]: [chars], exiting....

Explanation    The FIA driver encountered an event connection manager error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_ECM_REG Failed to register [chars] connection notification handler with the Event Connection Manager: [chars], exiting....

Explanation    The FIA driver encountered an event connection manager error. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_EIO_TRAIN EIO link training failure threshold reached. Link will not be re-trained. ASIC instance: [dec], EIO link ID: [dec]

Explanation    Repeated attempts to train the EIO links between the FIA and Ingressq/Fabric ASIC has failed. No further attempts to retrain the link will be made. This is indicative of a hardware failure on the serial link between the ASICs or an inter-process communication error between the driver processes.

Recommended Action    Collect the required information indicated below. Also, run the field diags and the health check. If the health check or diags fail, then initiate the RMA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_ENS_LIB Initialization Error: FIA-driver failed to initialize client library on [chars]. Reason: [chars]. Exiting

Explanation    FIA driver ENS client library initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_ENS_MSG Initialization Error: FIA-driver failed to send message to [chars]. Reason: [chars]. Exiting

Explanation    FIA driver ENS message communication error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_EVM_CREATE Initialization Error: FIA-driver failed to create Event Manager. Exiting.

Explanation    FIA-driver Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_EVM_INIT Failed to initialize the event manager: [chars], exiting...

Explanation    The FIA driver was unable to initialize an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_INIT Initialization Error [[chars]]: [chars], exiting....

Explanation    The FIA driver failed to initialize the device resulting in the restart of the FIA driver process. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    Verify that the fia_driver is up and running by executing the following command at the CLI of the active RP: 'show process fia_driver location ' If it is still non-operational, enable the following debugs of the FIA driver process: eio All EIO library events error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events Restart the driver by executing the following command at the CLI of the active RP: process restart fia_driver loc loc If the problem persists, this could be indicative of a hardware failure and it is recommended to run the field diagnostics on the failing MSC.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_INIT Initialization Error: FIA-driver failed to initialize [chars]. Reason: [chars]. Exiting

Explanation    Fabric driver subsystem initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_INIT_XAUI Initialization Error: FIA-driver failed to initialize XAUI interface with NP.[dec]. Exiting.

Explanation    FIA driver encountered a fatal error during interface initialization and is not able recover from the error after retries. A reason text will be supplied. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_MEM Initialization Error: FIA-driver could not map device memory

Explanation    FIA driver encountered a fatal memory allocation error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_MEM_ALLOC Memory allocation failed for internal data structures

Explanation    Memory was not available for an internal data structure. The requested operation could not be accomplished because of a low memory condition. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Run the debug show commands, gather data and contact tac. Also ensure the LC is populated with the minimum amount of memory required for proper operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_MEM_ALLOC Memory allocation failed for internal data structures

Explanation    Memory was not available for an internal data structure. The requested operation could not be accomplished because of a low memory condition. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Run the debug show commands, gather data and contact tac. Also ensure the LC is populated with the minimum amount of memory required for proper operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_MEM_ALLOC Memory allocation failed for internal data structures

Explanation    Memory was not available for an internal data structure. The requested operation could not be accomplished because of a low memory condition. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Run the debug show commands, gather data and contact tac. Also ensure the LC is populated with the minimum amount of memory required for proper operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_MEM_MAP Failed to map ASIC instance [dec] into memory (PROT flags: [dec], MAP flags: [dec]): [chars]

Explanation    The FIA driver was unable to map the hardware of the specified ASIC instance into its memory space and therefore failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_PLL Failed to lock TX slice PLL after [unsigned int] retries (ASIC instance: [dec], slice ID: [unsigned int]).

Explanation    While initializing the transmit slices of the FIA, the driver failed to lock the PLL. This is caused due to a clock synchronization problem between the MSC and the fabric board. This would result in loss of connectivity and bandwidth to affected fabric board.

Recommended Action    Collect the required information indicated below. Also, run the field diags and the health check. If the health check or diags fail, then initiate the RMA process. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_REGISTER Initialization Error: [chars] failed to register with [chars]. Exiting

Explanation    Fabric driver subsystem initialization error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_RESTART Initialization Error: FIA-driver exhausted maximum restart attempts to initialize. Exiting.

Explanation    FIA driver encountered a persistence fatal error during initialization and subsequent restarts. A reason text will be supplied. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-ERR_SHELFMGR_INIT Failed to [chars] due to [chars], [chars]

Explanation    The FIA driver failed to retrieve card state/type from shelfmgr. If the failure is due to a non EBUSY/EAGAIN error this will result in restart of the FIA driver process. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    Please collect the information specified in required_info section. Verify that the fia_driver is up and running by executing the following command at the CLI of the active RP: 'show process fia_driver location ' If it is still non-operational, enable the following debugs of the FIA driver process: eio All EIO library events error Errors in the driver fatal Fatal errors which cause driver to exit info All informational events init Initialization events Restart the driver by executing the following command at the CLI of the active RP: process restart fia_driver loc loc

Error Message     
 
    
    
   

%FABRIC-FIA-3-FFIAHW_ERR_FIFO [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. In this case parity error was detected in the FFIA internal reassembly memory. This error will trigger a recovery operation. The LC may not be able to forward data packets and traffic loss may be observed due to this error.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FFIAHW_ERR_FIFO [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. In this case parity error was detected in the FFIA internal memory. This error will trigger a recovery operation. The LC may not be able to forward data packets and traffic loss may be observed due to this error.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FFIAHW_ERR_PARITY [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. In this case the backpressure signals between FFIA and Tx PSE is having signal integrity issue. This error will trigger a recovery operation. The LC may not be able to forward data packets and traffic loss may be observed due to this error.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_CHIP Failed to configure [chars] config value : [hex] in hardware, fc_mask equals [hex], status equals [hex]

Explanation    The low level FIA driver was unable to complete its write operation. Possible cause is hardware failure. Error recovery will be triggered for this error. The direction value of fia_config passed and status returned of the failure are indicated in the message.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_CRC16 Too many CRC errors on fabric serial line (from slot [dec])

Explanation    This error indicates a problem in the interface between the card reporting error and the switch fabric card in the indicated slot. Data corruption is imminent.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, Move the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_CRC16 Too many CRC errors on fabric serial line (from fabric plane [dec])

Explanation    This error indicates a problem in the interface between the card reporting error and the switch fabric card in the indicated fabric plane. Data corruption is imminent.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, you can try moving the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_CRC16 Too many CRC errors on fabric serial line (from fabric plane [dec])

Explanation    This error indicates a problem in the interface between the card reporting error and the switch fabric card in the indicated fabric plane. Data corruption is imminent. Central Fabric control will take appropriate action to correct the situation.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If the cards are disabled, try the following 1. Ensure firmware running on all the cards are up to date. 2. Run field diagnostics on the card that is facing problem. 3. Take out the card and insert in a new slot to check if problem persists.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_DEVCTL FIA device access (read) failed for [chars]

Explanation    The low level fabric interface ASIC driver was unable to complete its hardware access operation. Hardware configuration may not have been successfully completed. This may result in traffic loss. The output of the show command may not be valid. The direction of the error is indicated in the message.

Recommended Action    Restart the fiad process on the LC. If the error persists, reload the LC using 'hw-module' command.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_EMPTY_DEST_SOFTREQ [chars] Empty destination software request error [hex]

Explanation    An unexpected error has occurred. This error typically means that a unicast or a multicast packet was received by the fabric interface ASIC to be forwarded across the switching fabric without any destination slot set in the header of the data packet. The direction of the error and the slot are indicated by the parameter in the message.

Recommended Action    None, this is a transient error and can be safely ignored. However multiple occurrences of this error indicates a software problem. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_EXT_FIFO [chars] [chars] ([hex])

Explanation    This error indicates a (possibly temporary) problem in the interface between the card reporting error and the switch fabric. Either the switch fabric is not able source or drain the data packets to this LC. This error is traffic affecting. Error recovery will be triggered. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, you can try moving the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_EXT_PARITY [chars] [chars] ([hex])

Explanation    This error indicates a (possibly temporary) problem in the interface between the card reporting error and the switch fabric. The error recovery will be triggered and the process should recover after a reset of the affected ASIC. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, you can try moving the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_INT Unexpected [chars] interrupt

Explanation    An unexpected error has occurred. This error will trigger an error recovery and is traffic affecting. The direction in which the error occurred is specified as part of the message. This error message indicates a masked interrupt occurred, even though its handled by the driver, this error should not have happened.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS Persistent LOS on serial link (from slot [dec])

Explanation    This error indicates a problem (Loss of Sync) in the interface between the card reporting error and the switch fabric card in the indicated slot. This error is traffic affecting. Error recovery is triggered by this error.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, Move the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS Persistent LOS on serial link (from fabric plane [dec])

Explanation    This error indicates a problem (Loss of Sync) in the interface between the card reporting error and the switch fabric card in the indicated fabric plane. This error is traffic affecting. Error recovery is triggered by this error.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If errors persist, you can try moving the card to another slot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS Persistent LOS on serial link (from fabric plane [dec])

Explanation    This error indicates a problem (Loss of Sync) in the interface between the card reporting error and the switch fabric card in the indicated fabric plane. This error is traffic affecting. Error recovery is triggered by this error.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.) If the cards are disabled, try the following 1. Ensure firmware running on all the cards are up to date. 2. Run field diagnostics on the card that is facing problem. 3. Take out the card and insert in a new slot to check if problem persists.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS_CLEAR LOS cleared on serial link (from fabric plane [dec])

Explanation    An earlier reported error (Loss of Sync) is now cleared. Normal operations can resume.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS_CLEAR LOS cleared on serial link (from fabric plane [dec])

Explanation    An earlier reported error (Loss of Sync) is now cleared. Normal operations can resume.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_LOS_CLEAR LOS cleared on serial link (from slot [dec])

Explanation    An earlier reported error (Loss of Sync) is now cleared. Normal operations can resume.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_MULTI_DEST_SOFTREQ [chars] Multi destination unicast software request error [hex]

Explanation    An unexpected error has occurred. This error typically means that a unicast data packet was received by the fabric interface ASIC to be forwarded across the switching fabric with more than one destination slot. The direction of the error and the slot are indicated by the parameter in the message.

Recommended Action    None, this is a transient error and can be safely ignored. However multiple occurrences of this error indicates a software problem. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_NOHALT Unexpected [chars] interrupt without halt

Explanation    An unexpected error has occurred. This error will trigger an error recovery procedure & is traffic affecting. The direction in which the error occurred is specified as part of the message.

Recommended Action    Wait atleast 3 minutes for the corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_RATE Error report timer wheel failure detected

Explanation    An internal data structure was missing a field. Some errors may not be reported to the fabric control software. This error indicates data corruption in internal structures.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_RATE Error report timer wheel failure detected

Explanation    An internal data structure was missing a field. Some errors may not be reported to the fabric control software. This error indicates data corruption in internal structures.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_RATE Error report timer wheel failure detected

Explanation    An internal data structure was missing a field. Some errors may not be reported to the fabric control software. This error indicates data corruption in internal structures.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_TMR Forced timeout of an internal timer failed, error [chars]

Explanation    The library call failed. This indicates internal data corruption on the LC. Certain errors may not be reported to the fabric control software.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_TMR Forced timeout of an internal timer failed, error [chars]

Explanation    The library call failed. This indicates internal data corruption on the LC. Certain errors may not be reported to the fabric control software. The error string as returned by the library call is included in the message.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_TMR Forced timeout of an internal timer failed, error [chars]

Explanation    The library call failed. This indicates internal data corruption on the LC. Certain errors may not be reported to the fabric control software.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_UNHANDLED Unexpected error case

Explanation    An unexpected error has occurred. This error will trigger an error recovery and is traffic affecting. An error other than the CRC or LOS has occurred.

Recommended Action    Wait atleast 3 minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_UNHANDLED Unexpected error case

Explanation    An unexpected error has occurred. This error will trigger an error recovery and is traffic affecting.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-FIAHW_UNHANDLED Unexpected error case

Explanation    An unexpected error has occurred. This error will trigger an error recovery and is traffic affecting.

Recommended Action    Wait several minutes for corrective action to occur. Ignore repeats of this error while corrective action is taking place. Look for error reports about the switch fabric (CSC/SFC.)

Error Message     
 
    
    
   

%FABRIC-FIA-3-LIBENS_ERR Error in [chars], slot:[dec] rc[[hex]]:[chars]

Explanation    FIA ENS lib has an access error

Recommended Action    Report the error

Error Message     
 
    
    
   

%FABRIC-FIA-3-LIBENS_INIT Init error in [chars], data:[hex] rc[[hex]]:[chars]

Explanation    FIA ENS client library initialization error

Recommended Action    Report the error.

Error Message     
 
    
    
   

%FABRIC-FIA-3-LIBENS_PRODUCER Error in [chars], data:[dec], handle[[hex]], rc[[hex]]:[chars]

Explanation    Fabric FIA ENS library producer error

Recommended Action    Report the error

Error Message     
 
    
    
   

%FABRIC-FIA-3-TFIAHW_ERR_PACKET [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. A corrupted packet was received from the Rx BMA, this indicates communication bus between the FIA and Rx BMA on the hardware datapath may have signal integrity issues. This error will trigger an error recovery. The LC may not be able to forward data packets and traffic loss may be observed due to this error. If this error is seen due to manual CSC switchover, this ios message can be safely ignored and no action is needed.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error.

Error Message     
 
    
    
   

%FABRIC-FIA-3-TFIAHW_ERR_PACKET [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. The LC may not be able to forward data packets and traffic loss may be observed due to this error. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-3-TFIAHW_ERR_PARITY [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. The internal parity error affects the communication bus between adjacent ASICs on the hardware datapath. The LC may not be able to forward data packets and traffic loss may be observed due to this error. The From Fabric or To Fabric direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    If the problem is seen only during failover operations like CSC card change or a RP Failover and all the nodes are running without issues. No action required. If the problem is continues check if there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. Collect following data.

Error Message     
 
    
    
   

%FABRIC-FIA-3-TFIAHW_ERR_PARITY [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware problem on the card. A corrupted packet was received from the SCA, this indicates communication bus between the FIA and SCA on the hardware datapath may have signal integrity issues. This error will trigger an error recovery. The LC may not be able to forward data packets and traffic loss may be observed due to this error.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-4-ERR_CHKPT Failed to [chars] checkpoint record: [chars]

Explanation    The FIA driver encountered an error while updating or accessing its checkpoint information. Further high availability of the driver may be impacted.

Recommended Action    Verify that the fia_driver process is up and running by executing the following command at the CLI of the active RP: 'show process fia_driver' If the high availability of the FIA driver is not important, then this message may be ignored. However, if this functionality is necessary then restart the FIA driver by issuing the following command at the CLI of the active RP: 'process restart fia_driver' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-4-ERR_SYSDB_CONN_TO_COID Failed to [chars] (despite connection to SysDB being open): [chars]

Explanation    The FIA driver was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-4-ERR_SYSDB_EDM_REG Failed to register [chars] (despite connection to SysDB being open): [chars]

Explanation    The FIA driver was unable to become an external data manager (EDM) despite having a connection to SysDB. The operation will be retried.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-4-FIAHW_RGMII_LINK_DOWN Warning: The IPC RGMII Link is Down

Explanation    This warning indicates that the RGMII Link is up after configuration

Recommended Action    Reconfigure the IPC Path

Error Message     
 
    
    
   

%FABRIC-FIA-4-FIAHW_UNHALT Warning: The FIA is unhalted before programming

Explanation    This warning indicates that the FIA is not in Halt State for Programming

Recommended Action    UnHalt the FIA before programming.

Error Message     
 
    
    
   

%FABRIC-FIA-4-FIAHW_WARNING_UNSUPPORTED_CARD Warning: This is an unsupported FABRIC Bandwidth for Chinook card

Explanation    This warning indicates that the Fabric bandwidth is not sufficient for Chinook to come up.

Recommended Action    Replace the card in 10G or 40G chassis.

Error Message     
 
    
    
   

%FABRIC-FIA-4-FIAHW_WARNING_UNSUPPORTED_CARD Warning: This is an unsupported SIP-600 card with lower revision Fabric Interface ASIC

Explanation    This warning indicates that this is an older version of SIP-600 card which does not have a supported Fabric Interface ASIC (FIA). As a result, any CSC switch-over, RP fail-over or fabric card OIR may result in FIA ASIC errors, and the router may experience abnormal behavior.

Recommended Action    Replace with a later version of SIP-600.

Error Message     
 
    
    
   

%FABRIC-FIA-5-ERR_DEV_NOT_FOUND Driver has not discovered ASIC instance [dec] yet [[chars]], retrying....

Explanation    The FIA driver is polling for the device.

Recommended Action    If the message appears once and then stops, there is no cause for concern. If it persists or if fia_driver gets respawned by sysmgr for not returning EOI, then this could indicate a problem.

Error Message     
 
    
    
   

%FABRIC-FIA-6-PCDS_STATS_TIMESTAMP_FAILURE pcds_get_timestamp failed for fia stats

Explanation    This is a message indicating FIA PCDS a debugging information collection has faced a problem in getting the time stamp to be associated with the statistics collected.

Recommended Action    If the card is currently not used in service, reload using 'hw-module' command can clear the error condition. If the card is already in service this message may be ignored.

Error Message     
 
    
    
   

%FABRIC-FIA-6-PCDS_STATS_TIMESTAMP_FAILURE pcds_get_timestamp failed for superfish stats

Explanation    This is a message indicating FIA PCDS a debugging information collection has faced a problem in getting the time stamp to be associated with the statistics collected.

Recommended Action    If the card is currently not used in service, reload using 'hw-module' command can clear the error condition. If the card is already in service this message may be ignored.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_CHKPT_INIT Failed to initialize checkpoint library: [chars].

Explanation    The FIA driver failed to initialize the checkpoint library. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_CHKPT_REG Failed to register checkpoint table: [chars].

Explanation    The FIA driver failed to register the checkpoint table. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_EVM Failed to attach [chars] to event manager:[chars], exiting...

Explanation    The FIA driver was unable to attach the indicated event / handler to the event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_EVM_ASYNC_ATTACH Failed to attach an asynchronous [chars] handler to event manager: [chars].

Explanation    The FIA driver was unable to attach the indicated asynchronous handler to the event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_EVM_CREATE Failed to create event manager for '[chars]': [chars], exiting...

Explanation    The FIA driver was unable to create an event manager for processing messages and hence failed to initialize. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed on [chars] thread: [chars]

Explanation    The FIA driver LWM event manager has failed to block on the indicated thread.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_LWM_REPLY Failed to send reply: [chars].

Explanation    The FIA driver failed to send messaging reply.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_MEM_ALLOC Failed to allocate memory.

Explanation    FIA driver memory allocation error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_SYSDB_EDM_DATALIST Failed to [chars] SYSDB EDM datalist: [chars].

Explanation    The FIA driver has failed to either create / add a external data manager datalist.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_SYSDB_EDM_OPEN Failed to open EDM event connection manager: [chars], exiting...

Explanation    The FIA driver to failed open the SysDB EDM connection by binding to it and registering using the event connection manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FIA-7-ERR_THREAD_CREATE Failed to create [chars] thread: [chars], exiting....

Explanation    The FIA driver failed to create the specified thread. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger MSC reload. After a certain number of MSC reloads, the shelf manager will permanently shutdown the MSC.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FIFO Messages

Error Message     
 
    
    
   

%FABRIC-FIFO-2-SW_FATAL_ERROR fatal s/w error encountered - [chars], [chars]

Explanation    An unrecoverable fatal s/w error was encountered, which results in severe board malfunction. The exact cause is appended to the error msg.

Recommended Action    Reload the board. *SUPPORT*

FSDB_FADB_MAIN Messages

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-EVT_MGR_CREATE_FAIL event manager create failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to create an event manager for process fsdb_fadb

Recommended Action    Search the event logs for events/errors related to the failure reason. Event management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-EXTRACT_NODE_ID_FAIL nodeid_extract_fields failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to extract info from node id in process fsdb_fadb

Recommended Action    Search the event logs for events/errors related to the failure reason. Node ID management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-GET_NODE_ID_FAIL platform_get_my_nodeid failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to get node id in process fsdb_fadb

Recommended Action    Search the event logs for events/errors related to the failure reason. Node ID management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-RESPAWN_COUNT_GET_FAIL respawn count get failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to attach sync event handler for process fsdb_fadb

Recommended Action    Search the event logs for events/errors related to the failure reason. Utility to get respawn count is part of overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-SYNC_HDLR_ATTACH_FAIL sync event handler attach failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to attach sync event handler for process fsdb_fadb

Recommended Action    Search the event logs for events/errors related to the failure reason. Event management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-SYSDB_BIND_FAIL sysdb bind failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to bind to the rack endpoint to get router inventory

Recommended Action    Search the event logs for events/errors related to the failure reason. Sysdb is part of overall system. If there are failures here, then other processes may also exhibit similar problems. A re-attempt for sysdb bind can be forced by restarting the fsdb_fadb process on the node of interest.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB_MAIN-3-SYSDB_LIST_FREE_FAIL sysdb list free failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to free a list while getting the sysdb inventory

Recommended Action    Search the event logs for events/errors related to the failure reason. Sysdb is part of overall system. If there are failures here, then other processes may also exhibit similar problems.

FSDB_FADB Messages

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB-3-SHM_CREATE_FAIL Shared memory creation failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to create the FADB shared memory.

Recommended Action    Search the event logs for events/errors related to the failure reason. Shared Memory Management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB-3-SHM_OPEN_FAIL shm_open failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to open the FADB shared memory

Recommended Action    Search the event logs for events/errors related to the failure reason. Shared Memory Management and disk access is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB-4-SHM_FILE_TRUNCATE_FAIL [chars]: shared memory file truncate failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to truncate the FADB shared memory file

Recommended Action    Search the event logs for events/errors related to the failure reason. Shared Memory Management and disk access is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB_FADB-4-SHM_MMAP_FAIL [chars]: shared memory mapping failed: [chars]

Explanation    FSDB FADB encountered an error while attempting to map the FADB shared memory

Recommended Action    Search the event logs for events/errors related to the failure reason. Shared Memory Management is part of overall system. If there are failures here then other processes may also exhibit similar problems. Collect all the event logs (show logging) and the output of the following command. 'admin show process fsdb_fadb location loc' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FSDB Messages

Error Message     
 
    
    
   

%FABRIC-FSDB-0-BARRIER_STALL_RACK_RELOAD Rack [dec] reloading due to fabric barrier stall on the rack. Fabric shutdown log saved in file [chars].

Explanation    Rack is brought down if RPs on the rack are detected stalling on fabric barriers. If the rack is isolated from fabric via CLI, then this is expected. If this message occurs otherwise, it could be due to a software error or an unexpected hw error.

Recommended Action    If fabric links, fabric cards or fabric chassis connecting to the rack are brought down via CLI, then this is expected. If the problem happens otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-0-BARRIER_STALL_ROUTER_RELOAD Router reloading due to fabric barrier stall. Fabric shutdown log saved in file [chars].

Explanation    Router is brought down if RPs on the dsc rack are detected stalling on fabric barriers. If the dsc rack is isolated from fabric via CLI, then this is expected. If this message occurs otherwise, it could be due to a software error or an unexpected hw error.

Recommended Action    If fabric links, fabric cards or fabric chassis connecting to the dsc rack are brought down via CLI, then this is expected. If the problem happens otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-0-FABRIC_LOSS_LC_RELOAD [chars] reloading due to loss of fabric connectivity

Explanation    A line-card is reloading after detecting that it has totally lost connectivity to the fabric. If all the fabric boards are OIR'ed or brought down through CLI, this is expected. If this message occurs otherwise, it could be due to a software error.

Recommended Action    If the fabric planes are brought down or the S3-Sponge links are brought down intentionally, then this is expected. If the problem happens otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-1-ERR_PLANE_CONFIG Fabric hardware found at location [chars] is inconsistent with current configured values : [chars]

Explanation    The fabric plane configuration for this multi-chassis system cannot be implemented with the hardware that has been discovered. This error may cause one or more fabric planes to stay down which will affect the bring up of the rest of the system. Possible causes could be incorrect admin plane configuration (i.e. the configuration states that slot 1 is the first card in a plane whereas slot 0 really is) or an incorrectly sized fiber module is inserted in a slot.

Recommended Action    Check the admin plane configuration to ensure that it corresponds with the actual physical topology of the system. If this configuration looks correct then contact support, otherwise correct the configuration and the system should recover.

Error Message     
 
    
    
   

%FABRIC-FSDB-1-FABRIC_UPDOWN Fabric [chars] for data traffic

Explanation    If the fabric is reported down, it means that none of the fabric planes are UP. If the fabric is not UP, system cannot be used for any data traffic.

Recommended Action    Ensure that fabric cards are installed in the system. For multichassis systems ensure that the fabric racks have booted and the fabric cables are installed. Fabric can come up late if the fabric rack or fabric cards are booted up late. Wait for more time to see if the fabric comes UP. For MC systems, check if plane admin config exists on the router. If not, configure the plane admin config. If condition persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-1-PLANE_UPDOWN Plane [dec] state changed to [chars]%s; [chars]

Explanation    If the plane is reported down other than when administratively brought down, it means that the sprayer cannot reach *any* destination on the plane. This a symptom of too many other fabric errors (DESTINATION_UPDOWN) than an error itself. The plane can no longer be used to send any traffic. If the plane is reported mcast_down, it means that certain fabric destinations are not reachable on this plane. It is still good for unicast traffic, but for destinations which are reachable on this plane.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-2-ERR_CONTROL_MSG Rack [dec] sent illegal fabric control message - [chars]

Explanation    Fabric control software running in another rack has notified a status change that is impossible or illegal.

Recommended Action    This error can be caused by an attempt to use the router with in a fabric configuration that is not supported. For example, there may be three or more line card racks that have dual-rack fabric cards installed. Ensure that the correct racks are installed in the router and that software displays the correct rack numbers and rack types for each rack. Ensure that the software fabric configuration is correct. If these steps do not find an error, restart fabric control software on the rack that produced this message, and on the rack sending the illegal message. 'admin process restart fsdb_server loc loc'. As restart process is disruptive, save output of all the commands mentioned in required_info before restarting the process. If problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-2-INVALID_PLANE_SHUT_REQ Plane [dec] is reported to be defective. Unable to shut down the plane: [chars]

Explanation    This indicates that fsdb aserver process has received the request to shut down a fault plane. The plane is not shut down by the fsdb aserver due to the reason mentioned.

Recommended Action    If the identified plane is not already shut, shut down the plane in admin configuration: controller fabric plane shutdown Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-2-MSG_TO_FSDB_FAILED_CONNECT Cannot connect to fabric management process to report plane [dec] defective

Explanation    This is to indicate that the process has failed to connect to the fabric management process to report that the plane is defective.

Recommended Action    1) Get the output from the following commands: 'sh controller fabric trace all' on the dSC sh diagnostic result location this node detail sh diagnostic trace error location all sh diagnostic trace message location all 2) shut down the identified faulty plane in admin configuration: controller fabric plane shutdown 3) restart the process that is seeing the issue Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-2-MSG_TO_FSDB_FAILED_SEND Cannot send report of plane [dec] defective to the fabric management process

Explanation    This is to indicate that the process has failed to send an IPC message to the fabric management process that the plane is defective.

Recommended Action    1) Get the output from the following commands: 'sh controller fabric trace all' on the dSC sh diagnostic result location this node detail sh diagnostic trace error location all sh diagnostic trace message location all 2) shut down the identified faulty plane in admin configuration: controller fabric plane shutdown 3) restart the process that is seeing the issue Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ASERVER_DOWNLOAD Fabric configuration download [chars]: [chars]

Explanation    Fabric control software failed to synchronize configuration details between the fsdb_server and fsdb_aserver processes. If the affected rack is being added to the system it cannot be brought into service. If the affected rack is already in service, then it cannot respond to fabric failures or changes.

Recommended Action    No action is necessary. If condition persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-DEVCTL_FAIL System failed to read rommon variable [chars]

Explanation    Fabric Status Database server (FSDB) failed to read a rommon variable.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_BUNDLE_LINK [dec] link down in bundle [chars] on plane [dec]

Explanation    This is to indicate that the no. of down links in a bundle has changed from zero to non-zero or vice versa.

Recommended Action    This message is expected if a cable is inserted or removed, or if a fabric card (or chassis) to which the cable connects is powered on or off, or rebooted. If a change to DOWN is seen in other circumstances it may be due to a hardware failure.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_BUNDLE_STATE Bundle [chars] on plane [dec] is [chars]

Explanation    Bundle state has changed. This can be because the state of one of the bundle ports comprising the bundle has changed. A bundle port is considered down if all the links comprising the bundle port go down.

Recommended Action    This message is expected if a cable is inserted or removed, or if a fabric card (or chassis) to which the cable connects is powered on or off, or rebooted. If a change to DOWN is seen in other circumstances it may be due to a hardware failure.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_CHKPT Failed to register checkpoint record: [chars]. Exiting...

Explanation    FSDB server encountered an error while updating or accessing its checkpoint information. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_CHKPT_INIT Failed to initialize check point library: [chars]. Exiting...

Explanation    FSDB was unable to setup the checkpointing facility to offer high availability functionality. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_DEBUG Failed to setup the debugging services: [chars]. Exiting...

Explanation    FSDB was unable to initialize the debugging services. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_DSC FSDB Server: DSC Error [[chars]]: [chars]

Explanation    Fabric Status Database server (FSDB) failed to communicate with the DSC server. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_ECM_CREATE Failed to create the event connection manager for [chars]: [chars]. Exiting...

Explanation    FSDB encountered an error while attempting to create an event connection manager for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_ECM_NOTIFY Failed to install ECM notification handler for [chars] path: [chars]. Exiting...

Explanation    FSDB encountered an error while attempting to install an ECM notification handler for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_EVM_CREATE Failed to create the event manager: [chars]. Exiting...

Explanation    FSDB encountered an error while attempting to create an event manager. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_GET_NODEID FSDB Server: Failed to [chars]: [chars]

Explanation    FSDB server failed to obtain either its node ID or extract rack/slot/instance information (having obtained the node ID). The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_INTERNAL [chars] : [chars]

Explanation    An internal error occurred that was expected to succeed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_PARSE_FILE Parse error in fabric definition file [chars], line [dec]

Explanation    A file describing switch fabric components has errors. Some fabric components cannot be brought into service.

Recommended Action    A failed or incomplete software upgrade could cause this error. It could also be caused by corruption of an existing definition file. Ensure that the definition file is not damaged. If the problem persists, re-install the fabric control software.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_RESYNC_ASSERT Restarting to recover from resync timeout

Explanation    During the deferral window, fsdb_server did not hear from a driver or rack due to some connection/transport issue. Restarting fsdb_server will try to recover it.

Recommended Action    This clearly indicates an underlying transport issue.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_RESYNC_TIMEOUT Timeout during initial synchronization with [chars]

Explanation    When FSDB starts up it attempts to resynchronize the state with all current entities. This message indicates that one or more of these entities has not responded within the timeout period. This could lead to FSDB having an inconsistent view of the fabric, and can potentially cause traffic loss.

Recommended Action    Restarting FSDB process on any racks suffering from traffic loss may help, if not, restart FSDBs on all racks might resolve the issue. 'admin process restart fsdb_server location loc' Since 'restart process' is a disruptive operation and all the previous state is lost, all the logs for the commands mentioned in required_info should be saved. If problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_SYSDB FSDB Server: Sysdb failed to [chars]: [chars]

Explanation    FSDB encountered a Sysdb communication failure. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_SYSDB_BIND Connection to the sysdb server failed: [chars]

Explanation    FSDB failed to open a connection to the Sysdb Server process for one of the paths. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_SYSDB_EDM_NOTIF_GEN FSDB Server: Failed generating [chars] notification: [chars]

Explanation    FSDB external data manager failed to generate a trap notification. Process would continue to run normally.

Recommended Action    This message indicate that trap notifications of the operational states of planes and bundles would not occur. If snmp manageability is not enabled, this message can be ignored. However, if this functionality is necessary then restart the process by issuing the following command at the CLI of the active RP after collecting all the output of all the specified commands. 'admin process restart fsdb_server/fsdb_aserver loc loc' Restart fsdb_server if the bundle state traps are missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_SYSDB_EDM_REG Failed to register as an EDM for [chars]: [chars], exiting...

Explanation    The FSDB was unable to become an external data manager (EDM) for the specified path. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger respective RP/SC switchover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_SYSDB_REG_NOTIF FSDB Server: Failed to register notification for [chars] path: [chars]. SNMP traps will not be generated for this path

Explanation    FSDB external data manager failed to register for notifications for the specified path. Process would continue to run normally, except that SNMP traps will not be generated for changes in fabric state.

Recommended Action    This message indicate that trap notifications of the operational states of planes and bundles would not occur. If snmp manageability is not enabled, this message can be ignored. However, if this functionality is necessary then restart the process by issuing the following command at the CLI of the active RP after collecting all the output of all the specified commands. 'admin process restart fsdb_server/fsdb_aserver loc loc' Restart fsdb_server if the bundle state traps are missing else if plane state traps are missing restart fsdb_aserver. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-ERR_UNKNOWN_FAB_DEF Cannot find fabric definition file [chars]

Explanation    A file describing switch fabric components is not present on the router.

Recommended Action    If the hardware installed in the router has changed, ensure that fabric control software has been upgraded to the correct version. If the correct software has been installed, report the problem to technical support.

Error Message     
 
    
    
   

%FABRIC-FSDB-3-OPEN_FAIL Unable to open [chars] after [dec] retries

Explanation    Fabric Status Database server (FSDB) failed to open a rommon file.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_DEST_CONN Node ([chars]) is not reachable on plane [dec]

Explanation    This is to indicate that a node has lost connectivity to a plane. Most likely, back plane connectivity between the node and the fabric card has failed.

Recommended Action    To fix the issue please reinsert the card and make sure it seats well. If that doesn't help than verify the integrity of mid-plane pins.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_FLED [chars] : [chars], LED(Row [dec], col [dec]), corresponding to node [dec]

Explanation    Fabric LED internal software error occurred. It is possible to continue operation, although some LEDs on fabric led board may incorrectly illuminate. However, if this functionality is necessary then restart the process by issuing the following command at the CLI of the active RP after collecting all the output of all the specified commands. 'admin process restart fsdb_server loc loc' *SUPPORT*

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_INTERNAL_WARN [chars] : [chars]

Explanation    FSDB encountered a minor internal software error. It is possible that fabric operates normally without any issues.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_THREAD_COND_SIGNAL Failed thread conditional signal on [chars]: [chars].

Explanation    FSDB encountered an error while attempting to signal a thread conditionally. The operation related to the resource will be affected and the process will continue to run normally.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_THREAD_COND_WAIT Failed thread conditional wait on [chars]: [chars].

Explanation    FSDB encountered an error while attempting to wait conditionally on a thread. The operation related to the resource will be affected and the process will continue to run normally.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_THREAD_MUTEX_LOCK Failed to lock [chars] mutex : [chars].

Explanation    FSDB encountered an error while locking a mutex to access the specified shared resource. The operation related to the resource may be affected while the process continues to run normally.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-ERR_THREAD_MUTEX_UNLOCK Failed to unlock [chars] mutex : [chars].

Explanation    FSDB encountered an error while locking unlocking a mutex to access the specified shared resource. The operation related to the resource may be affected while the process continues to run normally.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSDB-4-PLANE_SHUTDOWN It is advisable to have [chars] to be up. Shutting down all the planes will leave the router in unrecoverable state.

Explanation    In a CRS-16 system, at least one odd plane and at least one even plane is required. In others, at least one plane is required. If all the planes are shutdown, the router goes into an unrecoverable state.

Recommended Action    Try to unshut a plane. If it does not help, the only way out is to reload the router either from the CLI or power cycle.

Error Message     
 
    
    
   

%FABRIC-FSDB-6-BOOT_WITHOUT_FABRIC FSDB Aserver: System will boot without waiting for fabric to be up

Explanation    System is booting up without waiting for fabric to be up.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FSDB-6-PLANE_DEST_UNREACHABLE Fabric address [dec] unreachable on plane [dec]. [dec] links up. Threshold [dec]

Explanation    This message gives additional information related to a plane in multicast-down state. It reports the number of operating fabric links from the plane to the destination. The threshold reported is the number of fabric links that are required for the destination to be considered reachable.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FSDB-6-PLANE_GROUP_DISABLED Disabled fabric traffic from group [dec] of rack [dec] in plane [dec]. [dec] links up. Threshold [dec]

Explanation    This message gives additional information related to a plane in multicast-down state. It reports that a group of fabric cards are unable to send traffic to any destination. For CRS-1 16-slot chassis, group 0 is the upper shelf containing line cards 0 to 7. Group 1 is the lower shelf containing line cards 8 to 15 and both RPs The message reports the number of operating data links from the specified group to the fabric plane that are operating. The reported threshold is the number of data links that should be operating in order to make the fabric group usable.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FSDB-6-PLANE_GROUP_UNREACHABLE All fabric addresses in group [dec] of rack [dec] unreachable on plane [dec]. [dec] links up. Threshold [dec]

Explanation    This message gives additional information related to a plane in multicast-down state. It reports that a group of fabric addresses have become unreachable. For CRS-1 16-slot chassis, group 0 is the upper shelf containing line cards 0 to 7. Group 1 is the lower shelf containing line cards 8 to 15 and both RPs. The message reports the number of data links that are operating from the fabric plane to the specified group. The threshold is the number of data links that should be operating in order to make the fabric group reachable.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FSDB-6-PLANE_RACK_MCAST_DOWN Plane [dec] reported in multicast-down state by rack(s)[chars]

Explanation    This message gives additional information related to a plane in multicast-down state. The message contains a comma-separated list of the line card racks that reported the multicast-down state.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-FSDB-7-ERR_MEM_ALLOC Failed to allocate memory.

Explanation    FSDB has failed to allocate memory for its resources. This would affect proper functioning of fabric.

Recommended Action    This indicates a low-memory condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%FABRIC-FSDB-7-ERR_SYSDB_BAG_ENCODE FSDB Server: SYSDB Bag encode[[chars]]: [chars]

Explanation    FSDB server encountered error in sysdb bag encode operation. This could affect output of some of the fabric CLI commands.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FSTATSA Messages

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_BAG_REG Bag register error is detected; [chars].

Explanation    Fabric statistics aggregator process encountered a fatal error to register its bags to bag software. This software error will cause process termination for recovery The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_DEBUG_INIT_EVENT Debug initialization for the fstats/server/[chars] event failed; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to initialize debug facility and hence failed to initialize. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_DEBUG_REGISTER Debug registration for fabric statistics server failed; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to register debug facility and hence failed to initialize. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_EVM_CREATE Failed to create event manager; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to create its event manager for receiving events. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_GSP_GROUP_CREATE GSP group [chars] creation/join was failed; [chars]; rc equals [hex].

Explanation    Fabric statistics aggregator process encountered a fatal error to create group for group communication. This software error will cause process termination to recover. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_INTERNAL Internal software error: [chars]; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal internal software error. This software error will cause process termination to recover. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. *RECUR*

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_SYSDB_BIND Can't bind to SysDB at [chars]; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to bind to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_SYSDB_EDM_REG Failed to register SysDB EDM at [chars]; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to register EDM to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSA-3-ERR_SYSMGR_PROC_READY Failed to report process ready to sysmgr; [chars]

Explanation    Fabric statistics aggregator process encountered a fatal error to report process ready to sysmgr. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FSTATSC Messages

Error Message     
 
    
    
   

%FABRIC-FSTATSC-3-ERR_GSP_GROUP_CREATE GSP group [chars] creation/join was failed; [chars].

Explanation    Fabric statistics client library encountered failure of creating group for GSP group communication.

Recommended Action    Restart Fabric statistics client manually if the error is persistent.

Error Message     
 
    
    
   

%FABRIC-FSTATSC-7-ERR_DEBUG_CLEANUP Debug cleanup for fabric statistics client library failed: [chars]

Explanation    Fabric statistics client library encountered debug facility clean up failure.

Recommended Action    None.

Error Message     
 
    
    
   

%FABRIC-FSTATSC-7-ERR_DEBUG_INIT_EVENT Debug initialization for the fstats/client/[chars] event failed: [chars]

Explanation    Fabric statistics client library encountered debug facility initialization failure. When this error happens, the library will not able to enable debug.

Recommended Action    Restart Fabric statistics client manually if the error is persistent.

Error Message     
 
    
    
   

%FABRIC-FSTATSC-7-ERR_DEBUG_REG Debug registration for fabric statistics client library failed: [chars]

Explanation    Fabric statistics client library encountered debug facility registration failure. When this error happens, the library will not able to enable debug.

Recommended Action    Restart Fabric statistics client manually if the error is persistent.

Error Message     
 
    
    
   

%FABRIC-FSTATSC-7-ERR_GSP_LOOKUP GSP lightweight group [chars] lookup was failed; [chars].

Explanation    Fabric statistics client library encountered failure when it looks up Fabric server light weight group for light weight group communication. Normally, this is a transient error. It can be a true error if the error is persistent.

Recommended Action    Restart Fabric statistics client manually if the error is persistent in a specific fabric card. Restart Fabric statistics server manually if the error is persistent in many fabric cards.

FSTATSS Messages

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_BAG_REG Bag register error is detected; [chars].

Explanation    Fabric statistics server process encountered a fatal error to register its bags to bag software. This software error will cause process termination for recovery The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_DEBUG_INIT_EVENT Debug initialization for the fstats/server/[chars] event failed; [chars]

Explanation    Fabric statistics server process encountered a fatal error to initialize debug facility and hence failed to initialize. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_DEBUG_REGISTER Debug registration for fabric statistics server failed; [chars]

Explanation    Fabric statistics server process encountered a fatal error to register debug facility and hence failed to initialize. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_EVM_CREATE Failed to create event manager; [chars]

Explanation    Fabric statistics server process encountered a fatal error to create its event manager for receiving events. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_GSP_GROUP_CREATE GSP group [chars] creation/join was failed; [chars]; rc equals [hex].

Explanation    Fabric statistics server process encountered a fatal error to create group for group communication. This software error will cause process termination to recover. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_INTERNAL Internal software error: [chars]; [chars]

Explanation    Fabric statistics server process encountered a fatal internal software error. This software error will cause process termination to recover. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_MEM_ALLOC Could not allocate memory for [chars].

Explanation    Fabric statistics server process encountered memory allocation error for creating statistics database or storing statistics data. This software error will cause process termination to recover during process initialization. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    Memory allocation failures will happen if the router runs out of memory or memory leak in this process or other processes. User needs to do 'process restart memory hog process job id' to recover.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_SYSDB_BIND Can't bind to SysDB at [chars]: [chars]

Explanation    Fabric statistics server process encountered a fatal error to bind to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_SYSDB_EDM_REG Failed to register SysDB EDM at [chars]: [chars]

Explanation    Fabric statistics server process encountered a fatal error to register EDM to admin plane sysdb server. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-3-ERR_SYSMGR_PROC_READY Failed to report process ready to sysmgr; [chars]

Explanation    Fabric statistics server process encountered a fatal error to report process ready to sysmgr. This software error will cause process termination for recovery. The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. If the problem continues, sysmgr will trigger node reload. After a certain number of node reloads, the shelf manager will permanently shutdown the node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FSTATSS-7-ERR_RSC_REG_INCONSISTENT_VALUE [chars]: fabric resource registration error due to inconsistent value.

Explanation    Fabric statistics server process encountered a transient error due to the inconsistent checking of the received message. This error message will be a true error if many error message is logged and the error is persistent.

Recommended Action    If the error continues, user will need to restart the process for recovery.

HFR_FSDB_FADB_LTRACE Messages

Error Message     
 
    
    
   

%FABRIC-HFR_FSDB_FADB_LTRACE-3-ERROR_INIT_FAIL ltrace initialization operation failed for error traces: [chars]

Explanation    The FSDB FADB ltrace lib failed to initialize the error ltrace

Recommended Action    Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-HFR_FSDB_FADB_LTRACE-3-EVENT_INIT_FAIL ltrace initialization operation failed for events: [chars]

Explanation    The FSDB FADB ltrace lib failed to initialize the events ltrace

Recommended Action    Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-HFR_FSDB_FADB_LTRACE-3-INTERNAL_INIT_FAIL ltrace initialization operation failed for internal traces: [chars]

Explanation    The FSDB FADB ltrace lib failed to initialize the internal ltrace

Recommended Action    Search the event logs for events/errors related to the failure reason. Ltrace usage is common to overall system. If there are failures here then other processes may also exhibit similar problems. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

INGRESSQ_ALARM Messages

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_ALARM-2-DEVICE_HALT INGRESSQ: device halted, sub-block: [chars], halted entity: [chars]

Explanation    INGRESSQ, ASIC got halted. The halted block and its parent block are provided

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

INGRESSQ_DLL Messages

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-BRM_BARRIER_SYNCUP_FAILED BRM BlocK: Barrier sync up failed for this node.

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-ERR_ASIC_GENERIC [chars]

Explanation    Ingressq encountered a device error that has exceeded its threshold value. Driver takes appropriate action to log and fix the error which may include a device reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-ERR_BIST Error during [chars] BIST

Explanation    BIST failed for the mentioned block. The driver should trigger a device reset to fix this error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-ERR_INIT [chars]

Explanation    The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.

Recommended Action    Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: 'show fabric-snapshot file loc '

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-ERROR_HW_ACCESS [chars] Error: [chars]

Explanation    Ingressq Driver encountered an error during access to the ASIC. The error may have been caused because expected or unexpected software and hardware errors. In case, the error is a hardware error, Ingressq driver will reset the ASIC to recover.

Recommended Action    If the error persists, please contact TAC support.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-FATAL_ERR [chars] fatal error

Explanation    --

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-1-TAKING_NODE_DOWN Taking the node down, Reason: [chars]

Explanation    Ingressq DLL encountered an fatal error mentioned above. The driver triggers MSC node-down to recover from the error.

Recommended Action    This might be a recovery action from a fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-2-ERR_EIO_TRAIN EIO link training threshold exceeded, link: [dec]

Explanation    An attempt to train the EIO links to the neighboring Asic have failed. The ingressq driver retries the eio link training. If this error is seen repeatedly, please contact TAC support.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-2-TAKING_NODE_DOWN Taking the node down, Reason: [chars]

Explanation    Ingressq DLL encountered an fatal error mentioned above. The driver triggers MSC node-down to recover from the error.

Recommended Action    This might be a recovery action from a fault. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-BRM_BARRIER_SYNCUP_FAILED Barrier sync up failed for this node. Last sync state equals [dec]

Explanation    This may be a transient error seen if fabric components are powered down incorrectly. The system should recover from this error automatically. If the error persists, please contact TAC support.

Recommended Action    Check Fabric health and look for any disconnects between the fabric stages. Make sure that the fabric planes are up. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_FCRAM_ASSERT Assert Error valid: [dec], block: [dec], debug_info: [dec]

Explanation    Ingressq encountered an assert error in the FCRAM. The driver triggers a device reset. The device should be reinitialized.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_ASIC_MBE Multiple Bit Error in Block: [chars] Error: [chars] at Memory Address [hex].

Explanation    Ingressq encountered a multiple bit error in the mentioned block. This error is an uncorrectable error. Driver takes appropriate action to log and fix the error which may include a device reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_BIST Error during [chars] BIST

Explanation    BIST failed for the mentioned block. The driver should trigger a device reset to fix this error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_INIT [chars]

Explanation    The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.

Recommended Action    Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: 'show fabric-snapshot file loc '

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_MEM_ALLOC Error Allocating memory for [chars]

Explanation    The Ingressq dll Memory Allocation Error message.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-ERR_MEM_ALLOC Error Allocating memory for [chars]

Explanation    Ingressq encountered a fatal memory allocation error. If a new configuration being applied, the configuration will be rejected. The user may reapply the configuration. If the error happens normal operation, the process will restart to recover from this error.

Recommended Action    The driver/client processes try to recover from this error. If any discrepancies are found in the device functionality, contact TAC Support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-RESET Resetting IQM ASIC Device

Explanation    Ingressq, cpuctrl net interface encountered a CRC/Sync Error. This will result in the PIO or CDMA failure.

Recommended Action    If it is possible to isolate the trigger point for the sn link error, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-RESET [chars] Resetting IQM ASIC Device with halt status [hex] due to [chars]

Explanation    Ingressq Seal ASIC error halt occur.

Recommended Action    If it is possible to isolate the trigger point for the sn link error, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_POST_OP_FAILED Sequencer state: [dec], reason: [chars] : [chars], #retries: [dec]

Explanation    Ingressq driver state machine encountered a failure in initializing the device above threshold number of times. Driver will continue to initialize the device. If the error persists, please contact TAC support.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_POST_OP_FAILED Sequencer state: [dec], reason: [chars] : [chars], #retries: [dec]

Explanation    Ingressq driver state machine encountered a failure in initializing the device above threshold number of times. Driver will continue to initialize the device.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_PRE_OP_FAILED Exiting. sequencer state: [dec], reason: [chars] : [chars]

Explanation    Ingressq driver state machine encountered an unrecoverable error. This will result in driver restart.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location ' If it is still non-operational, enable the following debugs of the ingressq driver process: asic error asic fatal asic info and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-SEQ_STATE_PRE_OP_FAILED Exiting. sequencer state: [dec], reason: [chars] : [chars]

Explanation    Ingressq driver state machine encountered an unrecoverable error. This will result in driver restart.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times the error is encountered, to recover. Verify that the ingressq driver is up and running by executing the following command at the CLI of the active RP: 'show process ingressq location ' If it is still non-operational, enable the following debugs of the ingressq driver process: asic error asic fatal asic info and restart the driver by executing the following command at the CLI of the active RP: 'process restart ingressq location ' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-WDG_SEG_HUNG Spiller Seg blk is hung, reseting spiller - pkt_fifo [hex], ctrl_fifo [hex], icf_fifo [hex]

Explanation    Watchdog detected that spiller seg block is hung, resetting spiller to recover

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-3-WDG_SEG_HUNG Seal Seg blk is hung, reseting seal - pkt_fifo [hex], ctrl_fifo [hex], icf_fifo [hex]

Explanation    --

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_AGGR_DELTA_THRSHLD BRM aggr delta, spo link: [dec], cast: [dec], threshold: [unsigned long int]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_AGGR_DELTA_THRSHLD BRM aggr delta, egress link: [dec], cast: [dec], threshold: [unsigned long int]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_DELTA_THRSHLD BRM delta threshold, spo link: [dec], cast: [dec], threshold: [unsigned long int]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_DELTA_THRSHLD BRM delta threshold, egress link: [dec], cast: [dec], threshold: [unsigned long int]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_DID_CULPRIT BRM double in delta culprit, spo link: [dec], cast: [dec]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_DID_CULPRIT BRM double in delta culprit, egress link: [dec], cast: [dec]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_INVALID_INPUT BRM invalid input; spo: [dec], cast: [dec], current_barr: [hex] input_barr: [hex]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_INVALID_INPUT BRM invalid input; egress: [dec], cast: [dec], current_barr: [hex] input_barr: [hex]

Explanation    There might be a fabric disconnect in the system.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_PHASE_CHANGE_COUNTER BRM, phase didn't change, spo link: [dec], cast: [dec], phase: [hex], phase to counter: [hex], phase to thr: [hex]

Explanation    Barrier Manager encountered a phase change error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-BRM_PHASE_CHANGE_COUNTER BRM, phase didn't change, egress link: [dec], cast: [dec], phase: [hex], phase to counter: [hex], phase to thr: [hex]

Explanation    Barrier Manager encountered a phase change error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-CDMA_REQ_ERROR CpuCtrl error, addr:([hex],[hex]), dir: [dec], rc: [dec]

Explanation    CpuCtrl driver was not able to complete the CDMA request for the above specified address location. This may be caused if the device is not initialized correctly or synchronized correctly.

Recommended Action    If it is possible to isolate the trigger point for the cdma failure, collect all the necessary condition that caused the error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-CDMA_REQ_ERROR CpuCtrl error, addr:([hex],[hex]), dir: [dec], rc: [dec]

Explanation    CpuCtrl driver was not able to complete the CDMA request for the above specified address location. This may be caused if the device is not initialized correctly or synchronized correctly.

Recommended Action    If it is possible to isolate the trigger point for the cdma failure, collect all the necessary condition that caused the error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-CONFIG_ERR Ingressq received packets in invalid queue(s). [chars]

Explanation    Ingressq has various queues that are used by Ingress ASICs to send specific stream of traffic. These queues are specifically configured before they are used to forward traffic. Ingressq received a few packets in queues that were misconfigured or not configured at all. The driver will automatically try to recover from the condition.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_CRC CRC Error: Block:[chars] Error:[chars] Count: [dec]

Explanation    Ingressq block received a packet with a CRC error. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic. This error may cause performance degradation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_CRC CRC Error: Block:[chars] Error:[chars] Count: [dec]

Explanation    Ingressq block received a packet with a CRC error. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic. This error may cause performance degradation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_DROP Block: [chars] encountered error: [chars]. It received a packet with SOP/EOP/MAC error(s)

Explanation    Ingressq received a packet with SOP/EOP/MAC error It is primarily caused by either software or mac issue.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_LENGTH Block: [chars] encountered error: [chars]. It received a packet with length error(s), expected: [dec], received: [dec]

Explanation    Ingressq received a packet with incorrect length either from cpuctrl or Ingress PSE. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_LENGTH Block: [chars] encountered error: [chars]. It received a packet with length error(s), expected: [dec], received: [dec]

Explanation    Ingressq received a packet with incorrect length either from cpuctrl or Ingress PSE. It is primarily caused by either the link errors between the devices or packet corruption in the upstream asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_SN_LINK CpuCtrl Interface RxFIFO Error: [chars]

Explanation    Ingressq, cpuctrl net interface Rx FIFO last sync.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_ASIC_SN_LINK CpuCtrl Interface RxFIFO Error: [chars]

Explanation    Ingressq, cpuctrl net interface Rx FIFO last sync.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INIT Error encountered during Checkpoint Initialization

Explanation    Ingressq Checkpoint Init error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INIT Error encountered during Checkpoint Initialization

Explanation    Ingressq Checkpoint Init error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INSERT Error encountered during [chars] Checkpoint Insertion

Explanation    Ingressq Checkpoint Insert error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-ERR_CHKPT_INSERT Error encountered during [chars] Checkpoint Insertion

Explanation    Ingressq Checkpoint Insert error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-INTR_ENABLE_FAIL Interrupt enable at addr: [hex] mask: [hex] failed.

Explanation    Hardware state is not correct.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-INTR_ENABLE_FAIL Interrupt enable at addr: [hex] mask: [hex] failed.

Explanation    Hardware state is not correct.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-LNS_CCDF_OVERFLOW_ERROR control cell fifo overflow error

Explanation    Ingressq LNS control cell fifo overflow.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-LNS_CCDF_OVERFLOW_ERROR control cell fifo overflow error

Explanation    Ingressq LNS control cell fifo overflow.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-LNS_LOP_DROP Error: Cells dropped due to low availability of planes, aggr cell drop count: [unsigned long long int]

Explanation    Ingressq dropped a few cells because of unavailability of enough planes to forward the cells to its destination. If the cells are dropped intermittently during system reconfiguration (LC reload, RP fail over, etc.), then these drops are expected. System will recover after the hardware reprogramming completes. If these drops are seen continuously for long periods, then this indicates that either the node is not programmed correctly, or there is an error in data plane software.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-LNS_LOP_DROP Error: Cells dropped due to low availability of planes, aggr cell drop count: [unsigned long long int]

Explanation    Ingressq dropped a few cells because of unavailability of enough planes to forward the cells to its destination. If the cells are dropped intermittently during system reconfiguration (LC reload, RP fail over, etc.), then these drops are expected. System will recover after the hardware reprogramming completes. If these drops are seen continuously for long periods, then this indicates that either the node is not programmed correctly, or there is an error in data plane software.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-PFI_PARITY_ERROR parity error in plane RA, name: [chars], link: [dec], RA: [dec], Addr: [dec]

Explanation    Ingressq, cpuctrl net interface Rx FIFO last sync.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-4-PFI_PARITY_ERROR parity error in plane RA, name: [chars], link: [dec], RA: [dec], Addr: [dec]

Explanation    Ingressq, cpuctrl net interface Rx FIFO last sync.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_PARITY Block: [chars], entity: [chars] had parity error(s), addr: [dec], parity: [dec]

Explanation    In the specified block a parity error encountered at mentioned addr offset. If the error exceeds its threshold, the driver trigger a corrective action which may include device reset or MSC reload.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_PARITY Block: [chars], entity: [chars] had parity error(s), addr: [dec], parity: [dec]

Explanation    In the specified block a parity error encountered at mentioned addr offset. If the error exceeds its threshold, the driver trigger a corrective action which may include device reset or MSC reload.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-5-ERR_ASIC_SBE Single Bit Error in Block: [chars] Error: [chars] at Memory Address: [hex]

Explanation    Ingressq encountered a single bit error in the mentioned block. Persistent errors are corrected by the software. Non-persistent errors are automatically corrected by the next write operation.

Recommended Action    This error is an correctable error. There are no side effects. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-BRM_BARRIER_SYNCED_UP Barrier synced up on this node.

Explanation    This message indicates that system barriers synced on this node. This message is expected during normal operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_GENERIC Block: [chars], Generic Error [chars] at Memory Address [hex].

Explanation    Ingressq encountered a device error that has exceeded its threshold value. Driver takes appropriate action to log and fix the error which may include a device reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_OOR Block: [chars], entity: [chars] had Out Of Resources error(s), count: [dec]

Explanation    Ingressq block is unable to get packet memory for the incoming packets. This condition is caused by over subscription or hitting the Packet Per Second rate. This will affect the QOS. Thus it is recommended to reduce the packet rate to this MSC.

Recommended Action    Reduce the incoming packet rate to this MSC as under the OOR condition the QOS If the OOR is seen in non-oversubscribed case, contact TAC Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-ERR_ASIC_OOR Block: [chars], entity: [chars] had Out Of Resources error(s), count: [dec]

Explanation    Ingressq block is unable to get packet memory for the incoming packets. This condition is caused by over subscription or hitting the Packet Per Second rate. This will affect the QOS. Thus it is recommended to reduce the packet rate to this MSC.

Recommended Action    Reduce the incoming packet rate to this MSC as under the OOR condition the QOS If the OOR is seen in non-oversubscribed case, contact TAC Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-ERR_TX_CONN Ingressq links to plane(s) [chars] could not be brought up. Please check the connected planes

Explanation    Ingressq ASIC has 32 TX links into the fabric planes. This message lists the fabric planes that cannot be used by the Ingressq ASIC for data traffic.

Recommended Action    If these fabric planes have not been installed, please ignore this message. If these fabric planes have been installed, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-HEALTH_MONITOR [chars]

Explanation    Ingressq driver monitors the ASIC every 5 seconds to look for any problems/inconsistencies. If an error is reported momentarily, it could be a false positive seen during a transient state, or during oversubscription. In case, the error is seen repeatedly, please contact TAC support.

Recommended Action    If the error persists, please contact TAC support.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-INFO [chars]

Explanation    Just info

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-SEQ_STATE_THRESHOLD_EXCEEDED sequencer state: [dec], threshold: [dec], reason: [chars] [chars], #retries: [dec]

Explanation    Ingressq sequencer state threshold exceeded.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-SEQ_STATE_THRESHOLD_EXCEEDED sequencer state: [dec], threshold: [dec], reason: [chars], #retries: [dec]

Explanation    Ingressq sequencer state threshold exceeded.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALL_CLEARED [chars]: barrier stall cleared.

Explanation    Ingressq, Barrier stall cleared on one of the casts

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALL_CLEARED [chars]: barrier stall cleared.

Explanation    Ingressq, Barrier stall cleared on one of the casts

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALLED [chars]: barrier stalled.

Explanation    This may be a transient error seen if fabric components are powered down incorrectly. The system should recover from this error automatically. If the error persists, please contact

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-6-WDG_BARRIER_STALLED [chars]: barrier stalled.

Explanation    Ingressq, Barrier stalled on one of the casts

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-7-ERR_REGISTER_GET Register get failed for address [hex], Reason: [chars]

Explanation    An attempt to read a Hardware register failed. This could result in inconsistent behavior of the device.

Recommended Action    Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the read failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-7-ERR_REGISTER_GET Register get failed for address [hex], Reason: [chars]

Explanation    An attempt to read a Hardware register failed. This could result in inconsistent behavior of the device.

Recommended Action    Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the read failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-7-ERR_REGISTER_SET Register set failed for address [hex], Reason: [chars]

Explanation    An attempt to write a Hardware register failed.

Recommended Action    Run diags on the board and contact TAC support. If it is possible to isolate the trigger point for the set failure, collect all the necessary condition that caused the error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-7-ERR_RES_PROG Error during Resource Programming: [chars] Reason: [chars]

Explanation    Ingressq encountered an error during resource programming. If there are no further attempts to reprogram the device, the device behavior may be inconsistent.

Recommended Action    The driver/client processes try to recover from this error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_DLL-7-ERR_RES_PROG Error during Resource Programming: [chars] Reason: [chars]

Explanation    Ingressq encountered an error during resource programming. If there are no further attempts to reprogram the device, the device behavior may be inconsistent.

Recommended Action    The driver/client processes try to recover from this error. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

INGRESSQ_LIB Messages

Error Message     
 
    
    
   

%FABRIC-INGRESSQ_LIB-7-ERR_LWM_SEND Ingressq Lib: LWM Message send failed msg: [dec], retried: [dec] time(s), errno: [chars]

Explanation    Unable to send a LWM message to the Ingressq server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

INGRESSQ Messages

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-2-ASIC_RESET_FAILED Ingressq: Error encountered during Ingressq ASIC reset.

Explanation    Ingressq ASIC is reset before the MSC is powered down. If this reset fails, the fabric ASICs might complain of barrier errors. These errors should be transient, and the system will recover from it. In case, the errors aren't transient, please contact TAC support

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-3-ERR_INIT Fatal error encountered, reason equals [chars]

Explanation    The Ingressq driver failed to initialize the device resulting in the restart of the Ingressq driver process.

Recommended Action    Collect all the event logs and the output of the following command executed from the CLI of the active RP: 'show process ingressq' Also, collect the fabric snapshot: show fabric-snapshot file loc

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-3-ERR_MEM_ALLOC Error Allocating [dec] bytes of memory

Explanation    Ingressq encountered a fatal memory allocation error. If a new configuration being applied, the configuration will be rejected. The user may reapply the configuration. If the error happens normal operation, the process will restart to recover from this error.

Recommended Action    The driver/client processes try to recover from this error. If any discrepancies are found in the device functionality, contact TAC Support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-4-ERR_CHKPT_INIT Error encountered during Checkpoint Init. Exiting

Explanation    Ingressq Checkpoint Init error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-6-LINK_DOWN Ingressq: Link [dec] has been administratively shut down.

Explanation    Ingressq link has been shut down due to admin configuration. Ingressq ASIC won't be able to use this link for data traffic.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_BAG_REG Bag register failed for rules

Explanation    EDM Bags are used to share information between components using sysdb. This Error indicates that bag registration failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_CHKPT_DELETE Error encountered during [chars] Checkpoint Deletion

Explanation    Ingressq Checkpoint delete error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_CHKPT_INSERT Error encountered during [chars] Checkpoint Insertion

Explanation    Ingressq Checkpoint Insert error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_CLIENT_REG Client [chars] failed. Error: [chars]

Explanation    Ingressq client failed to Register/Unregister with Ingressq Server process. This error is also detected from the client's side. Retrial attempts would be made by the client.

Recommended Action    1. Verify the connectivity between the client and the Ingressq process. 'show controllers ingressq clients location ' Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_DLL_REG Dll registration for [chars] failed

Explanation    Ingressq driver tried to register for a dll but it encountered an error. The driver might lose some of its functionality.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_EVM_CREATE Event Manager create failed for [chars]

Explanation    Ingressq Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_EVM_NOTIFY Event Manager notify failed for [chars]

Explanation    Ingressq Event Manager notify error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_LWM_CREATE Event Manager create failed. Error([dec]) [chars]

Explanation    Ingressq Event Manager create error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_LWM_EVENT_BLOCK LWM Event Manager event block failed

Explanation    Ingressq Event Manager event block error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_LWM_REPLY An Error occurred during LWM message reply. Reason: [chars]

Explanation    Ingressq LWM reply error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_RES_PROG Error during Resource Programming: [chars] Reason: [chars]

Explanation    Ingressq encountered an error during resource programming. If there are no further attempts to reprogram the device, the device behavior may be inconsistent.

Recommended Action    The driver/client processes try to recover from this error. If any discrepancies are found in the device functionality, contact TAC Support. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_SYSDB_BIND Sysdb Bind failed.

Explanation    Ingressq Sysdb Bind error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_SYSDB_EDM_REG Sysdb Register EDM failed.

Explanation    Ingressq Sysdb Register EDM error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_SYSDB_REG_VERIFY Sysdb Registration verification failed.

Explanation    Ingressq Sysdb Registration verification error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-INGRESSQ-7-ERR_SYSDB_SET Sysdb Item Set Failed : [chars]

Explanation    Ingressq Sysdb Set error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.