Cisco IOS XR System Error Message Reference Guide, Release 3.9.0
Layer 2 Messages
Downloads: This chapterpdf (PDF - 2.26MB) The complete bookPDF (PDF - 52.83MB) | Feedback

Layer 2 Messages

Table Of Contents

Layer 2 Messages

10GE_PLIM Messages

ACCT_SVR Messages

ALPHA_TCAM Messages

ALPHA Messages

ASIC_ERRORS Messages

ASIC_SCAN_SERVER Messages

ATM_ILMI Messages

ATM_INARP Messages

ATM_NETIO Messages

ATM_OAM Messages

ATM_RM Messages

ATM_SAAR Messages

ATM_SOCKET Messages

ATM_SOP Messages

ATM_VCM Messages

atmdrv Messages

ATMGCMGR Messages

BFD Messages

BM_PD Messages

C_SHIM_PARTNER Messages

C12000_FR Messages

CCL Messages

CDP Messages

CEMA Messages

CFM Messages

CFMMIB Messages

CHDLC_EA Messages

CHDLC_MA Messages

CHDLC_SOCK Messages

CHDLCDLL Messages

CHIPs Messages

CHNLZD_EFCM Messages

COMMS Messages

CPP_ACL_EA Messages

CPP_EXMEM Messages

CPP_FM Messages

cpp_ifm Messages

CPP_LPTS_EA Messages

CPP_MDM Messages

CPP_PFILTER_EA Messages

cpp_sbs Messages

CPP_TCAM_RM Messages

CPP_UIDB Messages

CPPBQS Messages

cppdrv Messages

CPPHA Messages

cpposlib Messages

d1qnetio Messages

DI Messages

DIV2_DM Messages

DRIVERS_UTIL Messages

DWDM Messages

E3EGRESSQ Messages

E3INGRESSQ Messages

E5EGRESSQ Messages

E5INGRESSQ Messages

edge_l2fwd_rewrite Messages

edge_l2fwd_table Messages

EGRESSQ_HW_DLL Messages

EGRESSQ Messages

ELO_COMMON Messages

ELO Messages

ELOGM Messages

EMA Messages

EPI Messages

ESPI Messages

eth_gl Messages

ETH_OUTPUT Messages

ETHER_NETIO Messages

ether_spa_intr Messages

ether_spa_mac_error Messages

ether_spa_plugin Messages

ETHER Messages

FB_PLIM Messages

FB_SHIM_ENCAP Messages

FIB_IPV4 Messages

FIB_IPV6 Messages

FIB_MPLS Messages

FR_EDM Messages

FR_INARP Messages

FR_LMI Messages

FR_NETIO Messages

FR_SFRAR Messages

FR_SOCKET Messages

FR_UV Messages

FR_VCM_EA Messages

FR_VCM Messages

FRMIB Messages

FSYNC Messages

FWD_EDGE_COMMON Messages

GATM Messages

GDO Messages

GE_ASIC_PRP3 Messages

GE_ASIC Messages

GE Messages

GSR_aib Messages

GSR_edge_fwd_lib Messages

GSR Messages

GT64115 Messages

gulf Messages

HALE_MQS Messages

HALE_QOS Messages

HALE_REPLICORD Messages

HALE_TCAM Messages

HALE_TLU Messages

HFA_COMMON Messages

HFA_LIB Messages

if_discovery Messages

IGMPSN_POLICY Messages

IGMPSN Messages

IOB Messages

IPV6_EA Messages

IXP2800_FWD Messages

IXP2800_HW Messages

IXP2800_SERVICE Messages

IXP2800_VFW Messages

JACKET Messages

JDAM Messages

L2C Messages

L2FIB_DEBUG Messages

L2FIB_LIB Messages

L2FIB_SHM Messages

L2FIB Messages

L2TP Messages

L2VPN_DEBUG Messages

L2VPN_PW Messages

L2VPN Messages

LACP_LITE Messages

LC Messages

MARVEL Messages

METRO_STATS_API Messages

METRO_STATS Messages

METRO_UIDB Messages

MFR_EA_LTRACE_DLL Messages

MFR_EA_LTRACE Messages

MFR_EA Messages

MFR_MA Messages

MICKEY Messages

MLCTRLR Messages

MMSMLIB Messages

MOTHRA Messages

MOUSE Messages

MULTILINK_UV Messages

Multilink Messages

ND Messages

OAMMIB Messages

OC768_FRAMER_ASIC Messages

OPTICS Messages

PAL_CGM Messages

PFILTER_EA Messages

PLAOC768_API Messages

PLAOC768 Messages

PLATFORM_ATM_OAM Messages

plim_4p_oc12 Messages

PLIM_4P_OC192 Messages

PLIM_ASIC_API Messages

PLIM_ASIC Messages

PLIM_CLKSEL Messages

PLIM_FPGA Messages

PLIM_IOX_4P_GE Messages

PLIM_LIB Messages

plim_oc48 Messages

PLIM_OC768 Messages

PLIM Messages

pm5315 Messages

pm5316 Messages

PM622 Messages

PMSAR Messages

POS Messages

PPP_EA Messages

PPP_FSM Messages

PPP_GBL_CFG Messages

PPP_LCP Messages

PPP_lite Messages

PPP_MA Messages

PPP_NETIO Messages

PPP_SOCK Messages

PPPOE_EA Messages

PPPOE_GBL_CFG Messages

PPPOE_MA Messages

PRECAM Messages

PSE Messages

PSELIB Messages

QM_E5 Messages

QM Messages

QUEUEING Messages

RSMLIB Messages

Serial Messages

SLARP_LITE Messages

SLOGIC Messages

SONET_APS Messages

SONET_LOCAL Messages

SPA_192 Messages

SPA_ATM_V2 Messages

SPA_C_SHIM Messages

SPA_CHIN Messages

SPA_CHOC_DSX Messages

SPA_ETHER Messages

SPA_FPD Messages

SPA_OC3_OC12 Messages

SPA_OC48 Messages

SPA_PLIM_SB Messages

SPA_T3E3 Messages

SPA_THOR Messages

SPA Messages

SPABRG_384 Messages

SPABRG Messages

SPAMSG Messages

SPAN Messages

SPU_LIB Messages

SPU_VFW_LIB Messages

SPU_VFW Messages

SPU Messages

SRP Messages

SSRP Messages

STP_IO Messages

STP_LIB Messages

STP Messages

STREE Messages

TCAM_RM_CARVE_VERIFY Messages

TCAM_RM Messages

UDLD Messages

UIDB_RM Messages

VCM_CLIENT Messages

VCM_EA Messages

VCM Messages

vlan_netio Messages

vlea Messages

vlma Messages

VPA_1P_OC192 Messages

VPA_8P_GE Messages

VPA_RULES Messages

WAHOO Messages

WAN_INARP Messages

WAN_LIB_IFDB Messages

WAN_LIB_VCC Messages

WANPHY Messages

XCONNECT Messages


Layer 2 Messages


This section contains all Layer 2 related System Error Messages, including ATM, Ethernet drivers, Packet-over-Sonet (PoS), SONET, PLIMS, and so forth.

10GE_PLIM Messages

Error Message     
 
    
    
   

%L2-10GE_PLIM-2-RX_UNKNOWN Interface [chars], Detected PLA Fault

Explanation    The PLIM PLA ASIC had an unkown fault on the given interface which will result in a link flap.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-10GE_PLIM-2-STARTUP PLIM Process Error: [chars]

Explanation    The PLIM process failed to spawn correctly.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-10GE_PLIM-2-UNSUP This PLIM is no longer supported

Explanation    This PLIM is a prototype and is not longer supported

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-10GE_PLIM-2-XGXS_RX_SYNC An XGXS RX lane failed to synchronize for port [dec].

Explanation    The XGXS Rx Lanes failed to synchronize after a Xenpak OIR or Link Flap.

Recommended Action    Try to shut/no shut the port. If the MAC does not get enabled, then A physical OIR of the Xenpak device will be needed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-10GE_PLIM-2-XGXS_TX_SYNC An XGXS TX lane failed to synchronize for port [dec].

Explanation    The XGXS Tx Lanes failed to synchronize after a Xenpak OIR or Link Flap.

Recommended Action    Try to shut/no shut the port. If the MAC does not get enabled, then A physical OIR of the Xenpak device will be needed. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-10GE_PLIM-3-OIM_ERR An Optic Interface Module error occurred at port [dec], reason : [chars]

Explanation    A fatal error occurred in 10GE PLIM driver OIM rule validation.

Recommended Action    1. Remove the Xenpak and check if it is Cisco qualified Xenpak. 2. If it is Cisco qualified Xenpak, check DWDM Xenpak placement rule.

Error Message     
 
    
    
   

%L2-10GE_PLIM-4-INVALID_MAC Failed to get MAC address for Slot [dec], Port [dec], Interface assigned random MAC address.

Explanation    PLIM driver was unable to get a MAC address for the interface.

Recommended Action    Check if the process 'shelfmgr' is up and running on the RP. Try to reload the LC to see if that helps. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-10GE_PLIM-4-RX_LOSS Interface [chars], Detected RX Loss of Signal

Explanation    The PLIM received an Rx LOS or LF on the given interface which will result in a link flap.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-10GE_PLIM-4-RX_RF Interface [chars], Detected Remote Fault

Explanation    The PLIM received a remote fault on the given interface which will result in a link flap.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-10GE_PLIM-6-ERR_UPGRADE [chars]

Explanation    This is a Informational message in the plim_8p_10ge driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-10GE_PLIM-6-OIM_OIR Optic Interface Module [chars] for port [dec]

Explanation    The Optic Interface Module (OIM) for the specified port has either been inserted or removed.

Recommended Action    No action is required.

ACCT_SVR Messages

Error Message     
 
    
    
   

%L2-ACCT_SVR-3-ERR_INIT init error: [chars] - restarting process to recover.

Explanation    The process acct_svr encountered a software error while initializing. The process is exiting and will be restarted. System will not be affected.

Recommended Action    The process will be restarted automatically to recover.

Error Message     
 
    
    
   

%L2-ACCT_SVR-3-ERR_INIT init error: [chars] - restarting process to recover.

Explanation    The process acct_svr encountered a software error while initializing. The process is exiting and will be restarted. System will not be affected.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ACCT_SVR-3-ERR_INTERNAL software internal error: [chars] - restarting process to recover.

Explanation    The process acct_svr encountered an internal error. The process is exiting and will be restarted. System will not be affected.

Recommended Action    The process acct_svr will automatically be restarted to recover.

Error Message     
 
    
    
   

%L2-ACCT_SVR-3-ERR_INTERNAL software internal error: [chars] - restarting process to recover.

Explanation    The process acct_svr encountered an internal error. The process is exiting and will be restarted. System will not be affected.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ACCT_SVR-4-HFA_CLK_DELTA_FAIL HFA get clock delta has failed consecutively [dec] out of [dec] total times.

Explanation    The process acct_svr has failed to get the HFA clock delta for the given consecutive times.This log is printed out after so many consecutive failures to retrieve the clock delta, which may lead to skewed timestamps in the flow report.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ACCT_SVR-4-HFA_CLK_DELTA_FAIL HFA get clock delta has failed consecutively [dec] out of [dec] total times.

Explanation    The process acct_svr has failed to get the HFA clock delta for the given consecutive times. The flow report uses the forwarding asic clock which may be slightly off from the system clock. To correct the timestamp, the HFA clock delta is retrieve and on failure, the previously recorded delta is used. This log is printed out after so many consecutive failures to retrieve the clock delta, which may lead to skewed timestamps in the flow report.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ACCT_SVR-7-ISR_FIFO_USAGE_FLAG ISR FIFO ring buffer usage is [chars] threshold ([dec]). direction: [dec] num_items equals [dec]

Explanation    The process acct_svr detected the condition of ISR FIFO ring buffer usage above or below the threshold. If the usage is above the threshold, the process acct_svr will bring the ISR FIFO ring buffer usage back to below the threshold after a while. Traffic will not be affected by this condition.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ACCT_SVR-7-ISR_FIFO_USAGE_FLAG ISR FIFO ring buffer usage is [chars] threshold ([dec]). direction: [dec] num_items equals [dec]

Explanation    The process acct_svr detected the condition of ISR FIFO ring buffer usage above or below the threshold. If the usage is above the threshold, the process acct_svr will bring the ISR FIFO ring buffer usage back to below the threshold after a while. Traffic will not be affected by this condition.

Recommended Action    No action is required.

ALPHA_TCAM Messages

Error Message     
 
    
    
   

%L2-ALPHA_TCAM-3-ERROR_MSG
[chars], rc equals [hex], [chars]

Explanation    This is a error message in the HFA Alpha driver to indicate tcam carving error.

Recommended Action    Reload of LC will be workaround. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ALPHA Messages

Error Message     
 
    
    
   

%L2-ALPHA-3-ERR_ACCESS Memory access error: [chars]: Err equals [chars]

Explanation    A memory access error occurred in programable switching engine (PSE) driver which involves exiting the process. %s - indicates the reason for the failure. %s - is the decoded error reason.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ALPHA-3-ERROR_MSG
[chars] [chars]: [hex] [hex]

Explanation    This is a error message in the HFA Alpha driver to indicate either anomolies which are not service impacting. Some of the messages may indicate a failure to allocate resources needed by applications. This error may occur during the error recovery mechanism for programmable switching engine (PSE) while HFA Alpha driver fixes the parity errors in the memories after restart of the PSE.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ALPHA-6-VERSION_WARNING [chars] [chars] error [hex]

Explanation    This is an informational message in the programable switching Engine driver to indicatng unsupported version of programmable Switching engine (PSE) for some features. %s - is the warning message. %s - is the decoded warning reason. %x - is the decoded error code.

Recommended Action    Debug message only. No action is required.

Error Message     
 
    
    
   

%L2-ALPHA-7-INFO_MSG [chars] [chars]

Explanation    This is an informational message in the programable switching Engine driver to indicate an operation. %s - indicates the direction of the PSE. %s - is the decoded informational reason.

Recommended Action    Debug message only. No action is required.

Error Message     
 
    
    
   

%L2-ALPHA-7-PHB_DUMP
[hex]: [hex] [hex] [hex] [hex]

Explanation    This is a debug message to display PHB dump of programable switching engine (PSE).

Recommended Action    Debug message only. No action is required.

Error Message     
 
    
    
   

%L2-ALPHA-7-REG_DUMP
[chars]
cpu_int [hex] cpu_mask_int_reg [hex] error_addr_reg [hex]
error_data_hi_reg [hex] error_data_lo_reg [hex] error_parity_reg [hex]
fs_error_reg [hex] pf_err_reg [hex] prep_int_status_reg [hex]
prep_pc_reg [hex] pc1_status_reg [hex] plu_int_reg [hex]
plu_int_en_reg [hex] plu_err_en_reg [hex] plu_ecc_error_reg [hex]
plu_ecc_syndrome_reg [hex] tlu_int_reg [hex] tlu_sdram_adr_err_reg [hex]
tlu_sdram_ecc_syndrome_reg [hex] mip_int_status_reg [hex] mip_pc_reg [hex]
pc2_status_reg [hex] pst_status_reg [hex] cam_status_reg [hex]
nf_stat_reg [hex] pop_int_status_reg [hex] pop_pc_reg [hex]
ssram_adr_err_reg [hex] ssram_err_data_reg [hex] pl_pipeline_ctl_reg [hex]
pl_aa_pak_avl_1_reg [hex] pl_aa_end_reg [hex] pl_aa_fatal_err_reg [hex]
gather_int_stat_reg [hex] xbm_read_status_reg [hex] xbm_rcl_w_status_1_reg [hex]
xbm_rcl_w_status_2_reg [hex] xbm_rcl_r_status_reg [hex] xbm_tail_w_status_1_reg [hex]
xbm_tail_w_status_2_reg [hex] xbm_tail_w_status_reg [hex] xbm_control_status_1_reg [hex]
xbm_control_status_2_reg [hex] fs_pcr_reg [hex] prep_pair_reg[0] [hex]
plu_pcr_reg [hex] pc1_pcr_reg [hex] tlu_pcr_reg [hex]
dummy_pcr_reg [hex] mip_pair_reg[0] [hex] pc2_pcr_reg [hex]
cam_match_pcr_reg [hex] pst_pcr_reg [hex] pop_pair_reg[0] [hex] gather_pcr_reg[hex]

Explanation    This is a debug message to display registers of programable switching engine (PSE).

Recommended Action    Debug message only. No action is required.

ASIC_ERRORS Messages

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_CREATE ASIC Error library has failed to create an Event Connection Manager. Reason: [chars].

Explanation    The ASIC Error library encountered an error during the creation of the Error Connection Manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_CREATE ASIC Error library has failed to create an Event Connection Manager. Reason: [chars].

Explanation    The ASIC Error library encountered an error during the creation of the Error Connection Manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_CREATE ASIC Error library has failed to create an Event Connection Manager. Reason: [chars].

Explanation    The ASIC Error library encountered an error during the creation of the Error Connection Manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_REG ASIC Error library has failed to register a connection notification handler with the Event Connection Manager. Reason: [chars].

Explanation    ASIC Error library encountered an error while setting up a SYSDB notofication handler with the event connection manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_REG ASIC Error library has failed to register a connection notification handler with the Event Connection Manager. Reason: [chars].

Explanation    ASIC Error library encountered an error while setting up a SYSDB notofication handler with the event connection manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_ECM_REG ASIC Error library has failed to register a connection notification handler with the Event Connection Manager. Reason: [chars].

Explanation    ASIC Error library encountered an error while setting up a SYSDB notofication handler with the event connection manager.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB ASIC Error library failed to [chars]. Reason: [chars].

Explanation    ASIC Error library encountered an error during the specified SYSDB operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB ASIC Error library failed to [chars]. Reason: [chars].

Explanation    ASIC Error library encountered an error during the specified SYSDB operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB ASIC Error library failed to [chars]. Reason: [chars].

Explanation    ASIC Error library encountered an error during the specified SYSDB operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_BAG_ENCODE ASIC Error library: Encountered SYSDB Bag encode error [chars] during [chars] operation.

Explanation    ASIC error library encountered a SYSDB encode error while performing the indicated operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_BAG_ENCODE ASIC Error library: Encountered SYSDB Bag encode error [chars] during [chars] operation.

Explanation    ASIC error library encountered a SYSDB encode error while performing the indicated operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_BAG_ENCODE ASIC Error library: Encountered SYSDB Bag encode error [chars] during [chars] operation.

Explanation    ASIC error library encountered a SYSDB encode error while performing the indicated operation.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_EDM_REG ASIC Error library has failed to register an EDM. Reason: [chars].

Explanation    The ASIC Error library was unable to become an external data manager despite having a connection to the SYSDB.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_EDM_REG ASIC Error library has failed to register an EDM. Reason: [chars].

Explanation    The ASIC Error library was unable to become an external data manager despite having a connection to the SYSDB.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

Error Message     
 
    
    
   

%L2-ASIC_ERRORS-7-ERR_SYSDB_EDM_REG ASIC Error library has failed to register an EDM. Reason: [chars].

Explanation    The ASIC Error library was unable to become an external data manager despite having a connection to the SYSDB.

Recommended Action    An error would be reported to the client application which should handle this condition appropriately. *None*

ASIC_SCAN_SERVER Messages

Error Message     
 
    
    
   

%L2-ASIC_SCAN_SERVER-2-NODE_BRINGDOWN [chars]

Explanation    This is a message in the Asic Scan Server to indicate that it has triggerred a critical alarm and will result in node bringdown. The reason for the failure and the status of the scan operation is reported.

Recommended Action    Run the board diagnostics.

Error Message     
 
    
    
   

%L2-ASIC_SCAN_SERVER-7-ERR_EVM_CREATE ASIC Scan Server failed to create the event manager: Reason equals [chars].

Explanation    ASIC scan server has failed to create the event manager. This would result in the automatic restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ASIC_SCAN_SERVER-7-ERR_INIT ASIC Scan Server encountered error [[chars]]: Reason equals [chars].

Explanation    ASIC scan server has failed the initialization sequence due to the specified reason. This would result in the automatic restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ASIC_SCAN_SERVER-7-ERR_IO ASIC Scan Server failed to [chars]: Reason equals [chars].

Explanation    ASIC scan server has failed the specified io operation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ATM_ILMI Messages

Error Message     
 
    
    
   

%L2-ATM_ILMI-2-IM_ERR [chars] : [chars]

Explanation    Error in IM operation

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_ILMI-2-INTERNAL_ERR [chars] : [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_ILMI-2-SYSDB_ERR [chars]

Explanation    Error in sysdb operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

ATM_INARP Messages

Error Message     
 
    
    
   

%L2-ATM_INARP-2-INTERNAL_ERR [chars] : [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_INARP-2-NOMEM Operation failed due to memory shortage, function: [chars]

Explanation    Memory on the box is critically low.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

ATM_NETIO Messages

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-CARD_DLL Failed to open card specific dll [chars]

Explanation    Card specific dll may not be present

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-INSERT_DICT Insertion to ATM Netio Dictionary fails

Explanation    The env variable setting may not be set up for load path variable

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-INVALID_DLL DLL not found for the specified card : [chars]

Explanation    Check the installation Dlls missing from package

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-LOAD_PATH Failed to get load path env variable for dll [chars]

Explanation    The env variable setting may not be set up for load path variable

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-MEMORY Failed to malloc [unsigned int] bytes

Explanation    The DLL has failed to acquire the required amount of memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-PARSE_FAILURE Failed to parse atm_netio.rules at line: [chars]

Explanation    The file atm_netio.rules has been modified and parsing fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-3-PARSER_NULL_PATH Path to load the atm_netio.rules is NULL

Explanation    The path to atm_netio.rules file cannot be located.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_NETIO-6-DEBUG_REG Debug registration failed: [chars]

Explanation    Debug message registration failed

Recommended Action    No action is required.

ATM_OAM Messages

Error Message     
 
    
    
   

%L2-ATM_OAM-2-IM_ERR [chars] : [chars]

Explanation    Error in IM operation

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_OAM-2-INTERNAL_ERR [chars] : [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_OAM-2-SYSDB_ERR [chars]

Explanation    Error in sysdb operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

ATM_RM Messages

Error Message     
 
    
    
   

%L2-ATM_RM-1-SYSDB_ERR [chars] : [chars]

Explanation    Error in sysdb operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-ATM_RM-2-INTERNAL_ERR [chars] : [chars]

Explanation    A critical function failed that expected to succeed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_RM-2-NOMEM Failed to allocate [dec] bytes due to memory shortage

Explanation    Memory on the router is critically low.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-ATM_RM-4-BANDWIDTH_ERR [chars] : Bandwidth available [unsigned int] : Failed to reserve [unsigned int]

Explanation    Insufficient bandwidth available. possible cause: Too many vc's inheriting QoS from class parameters

Recommended Action    check vc class configuration on interface If there are vcs you want specific QoS values for under the main interface, try configuring QoS on these vcs before applying class to the interface in order to stop unwanted inheritance. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ATM_SAAR Messages

Error Message     
 
    
    
   

%L2-ATM_SAAR-2-INIT Failed to initialise ATM SAAR: [chars] ([chars])

Explanation    There was an error initialising the ATM SAAR component.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_SAAR-6-DEBUG_REG Debug registration failed: [chars]

Explanation    Debug message registration failed

Recommended Action    No action is required.

ATM_SOCKET Messages

Error Message     
 
    
    
   

%L2-ATM_SOCKET-2-INTERNAL_ERR [chars] : [chars]

Explanation    A critical function failed that expected to succeed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_SOCKET-2-NOMEM Allocation of [dec] bytes failed due to memory shortage

Explanation    Memory on the router is critically low.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-ATM_SOCKET-3-RESMGR_ATTACH Failed to setup atm socket as a resource manager: [chars]

Explanation    The atm_io process failed to advertise itself to the system as a resource manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ATM_SOP Messages

Error Message     
 
    
    
   

%L2-ATM_SOP-3-INTR ATM SOP Intr: [chars]: [dec]: [chars]: [dec] [chars]

Explanation    The SOP FPGA has been interrupted due a hardware error

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_SOP-7-DEBUG ATM SOP DEBUG: [chars]: [hex]: [hex]: [hex]

Explanation    ATM SOP debug message

Recommended Action    No action is required.

ATM_VCM Messages

Error Message     
 
    
    
   

%L2-ATM_VCM-2-IM_ERR [chars] : [chars]

Explanation    Error in IM operation

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_VCM-2-INTERNAL_ERR [chars] : [chars] : [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATM_VCM-2-SYSDB_ERR [chars]

Explanation    Error in sysdb operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

atmdrv Messages

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR [chars], [dec] error, reason:[chars]

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR [chars], [dec] error, reason:[chars]

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_ENCAP [chars] - [dec]: [chars] rc equals [hex] connid equals [dec] key equals [hex]

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_ENCAP [chars] - [dec]: [chars] rc equals [hex] connid equals [dec] key equals [hex]

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_STS [chars] - [dec]: [chars] (rc equals [hex])

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_STS [chars] - [dec]: [chars] (rc equals [hex])

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_VC [chars] - [dec]: [chars] (connid equals [dec])

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-2-ERR_VC [chars] - [dec]: [chars] (connid equals [dec])

Explanation    atmdrv generic error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-3-cpk_err [chars]. Port [dec]: number of occurance equals [unsigned int] intr_status equals [hex]

Explanation    atmdrv cpk24 interrupt handling related errors, or alerts

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-3-cpk_err [chars]. Port [dec]: number of occurance equals [unsigned int] intr_status equals [hex]

Explanation    atmdrv cpk24 interrupt handling related errors, or alerts

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-4-warning [chars], [dec] warning, reason:[chars]

Explanation    atmdrv warning message

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, and mail this message to your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-4-warning [chars], [dec] warning, reason:[chars]

Explanation    atmdrv warning message

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, and mail this message to your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-atmdrv-7-db_dump reason:[chars] port:[dec], vpi/vci:[dec]/[dec], connid:[dec], channels(r/s):[hex]/[hex], shape:[dec], encap:[dec]

Explanation    atmdrv debug message

Recommended Action    None

ATMGCMGR Messages

Error Message     
 
    
    
   

%L2-ATMGCMGR-2-DBG_INIT Failed to initialize [chars], because of [chars].

Explanation    A failure occurred during the initialization of the debug events.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ATMGCMGR-2-INIT Failed to initialize [chars], because of [chars].

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

BFD Messages

Error Message     
 
    
    
   

%L2-BFD-3-CHANGE_ECHO_SOURCE_ADDRESS_FAILED BFD session to neighbor [chars] on interface [chars] has failed to update echo source address to [chars].

Explanation    Failed to change echo source address and construct echo packet hdr for BFD session.

Recommended Action    Recreate the BFD session and reconfigure echo source address for it.

Error Message     
 
    
    
   

%L2-BFD-3-REVERT_ECHO_SOURCE_ADDRESS_FAILED BFD session to neighbor [chars] on interface [chars] has failed to revert echo source address to [chars].

Explanation    Failed to revert echo source and construct echo packet hdr for BFD session.

Recommended Action    Recreate the BFD session and reconfigure echo source address for it.

Error Message     
 
    
    
   

%L2-BFD-3-REVERT_ECHO_SOURCE_ADDRESS_SECCUSS BFD session to neighbor [chars] on interface [chars] has reverted echo source address to [chars].

Explanation    Revert echo source and construct echo packet hdr for BFD session successfully.

Recommended Action    Recreate the BFD session and reconfigure echo source address for it.

Error Message     
 
    
    
   

%L2-BFD-4-ASYNC_DETECT_TIMER_FAULTY_EXPIRY BFD Async Detect timer expired for neighbor [chars] interface [chars] even when async pkt received within timer duration, timer_duration equals [unsigned int] ms, [unsigned int] ms elapsed since last async pkt received

Explanation    BFD Async Detect timer expired even when async pkt received within timer duration, timer_duration

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-4-RATE_LIMIT_WARNING_HIGH_WATERMARK BFD PPS allocation exceeds 90 percent of maximum.

Explanation    BFD has allocated 90 percent of its packet per second allowance on this LC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-4-RATE_LIMIT_WARNING_LOW_WATERMARK BFD PPS allocation now less 85 percent of maximum.

Explanation    BFD has released some of the previously allocated packet per second usage and is now at less than 85 percent of its allowance on this LC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-ADJACENCY_DELETE Adjacency for neighbor [chars] on interface [chars] was deleted

Explanation    The adjacency for neighbor ip address was deleted.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-FIB_NOT_READY Forwarding is not ready for neighbor [chars] on interface [chars]

Explanation    The forwarding for session is not ready.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-MAX_AGENT_SESSIONS_EXCEEDED Number of requested sesssions has exceeded limit [dec]

Explanation    Each linecard is only able to host specific number of BFD sessions. This message indicates that maximum number of hosting BFD sessions has reached its maximum. Those session creating requests after reaching this limit will purposely be prevented from being created. These prevented sessions will continuously be retried to be created in the These prevented sessions will continuously be retried to be created in the background, and they will be once resources are available (ex: once some existing essions are deleted). Those sessions in the retry queue can be viewed via 'show bfd session pending' command.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_NO_RESOURCES No resources for session to neighbor [chars] on interface [chars], interval equals [unsigned int] ms[chars]

Explanation    The BFD session can not be created or modified due to lack of resources.

Recommended Action    Remove other BFD sessions to free resources for this session

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_NO_RESOURCES_CLR Lack of resources condition has cleared for session to neighbor [chars] on interface [chars]

Explanation    Resources are now available for this session.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_REMOVED BFD session to neighbor [chars] on interface [chars] has been removed

Explanation    The BFD session has been removed. This is due to the application(s) removing the BFD session. This can happen as a result of BFD being unconfigured under the application(s) or as a result of the application(s) adjacency being removed.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_STATE_DOWN BFD session to neighbor [chars] on interface [chars] has gone down. Reason: [chars]

Explanation    The BFD session has gone down. This may be as a result of the forwarding path being down.

Recommended Action    Determine if the forwarding path to the neighbor has gone down.

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_STATE_UP BFD session to neighbor [chars] on interface [chars] is up

Explanation    The BFD session is now up.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-BFD-6-SESSION_VERSION_CHANGE BFD session to neighbor [chars] on interface [chars] is administratively down due to version change from version [unsigned int] to version [unsigned int]

Explanation    The BFD session has been brought administratively down to change protocol version.

Recommended Action    No action is required.

BM_PD Messages

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_CERRNO Failure registering cerrno DLL with subsys num [unsigned int] and DLL name [chars]. Error: [chars]

Explanation    A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_CERRNO Failure registering cerrno DLL with subsys num [unsigned int] and DLL name [chars]. Error: [chars]

Explanation    A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_CERRNO Failure registering cerrno DLL with subsys num [unsigned int] and DLL name [chars]. Error: [chars]

Explanation    A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_CERRNO Failure registering cerrno DLL with subsys num [unsigned int] and DLL name [chars]. Error: [chars]

Explanation    A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_CERRNO Failure registering cerrno DLL with subsys num [unsigned int] and DLL name [chars]. Error: [chars]

Explanation    A failure occurred during the registration of the DLL for decoding error codes from the component. This may render certain codes unprintable, but otherwise has no negative impact.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent bundle Manager adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform dependent adjacency programming DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-3-DLL_TRACE Failure initializing tracing ([chars] buffer). Error: [chars]

Explanation    A failure occurred during the initialization of tracing for the adjacency management DLL. This will cause the DLL to be unloaded, and adjacency programming will not happen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-BASE_MAC Unable to obtain base MAC address

Explanation    LRd returned a NULL MAC address to be used as the base MAC address for the system and bundle MAC addresses.

Recommended Action    Check the VT topology definition file to ensure a Host MAC Address is specified. Check the LRd stub library and VT IO code to see if there is a bug in accessing the defined value.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_ADJ_CMPL_DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform independent adjacency completion DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_ADJ_DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform independent adjacency completion DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_ADJ_DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform independent adjacency completion DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_ADJ_DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the platform independent adjacency completion DLL. This will result in the hosting process being restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_ADJ_DLL_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the bundlemgr adjacency process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-BM_PD-4-ERR_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

C_SHIM_PARTNER Messages

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-AIB_INIT_FAILED Failed during AIB initialization, err: [chars]

Explanation    The C-shim Partner initialization failed while trying to connect to AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-AIB_INIT_FAILED Failed during AIB initialization, err: [chars]

Explanation    The C-shim Partner initialization failed while trying to connect to AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_ADD_ERR Fatal Error: Adding batched channelized interface caps failed. Reason: [chars]

Explanation    'There is an error when adding batched channelized interface caps.'

Recommended Action    Please try to reload that particular SPA or restart the SPA process associated with that SPA. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_ADD_ERR Fatal Error: Adding batched channelized interface caps failed. ifh [hex],Reason: [chars].

Explanation    'There is an error when adding batched channelized interface caps.'

Recommended Action    Please try to reload that particular SPA or restart the SPA process associated with that SPA. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_CNTL_ERR Fatal Error: Failed to modify channelized interface caps. Reason: [chars]

Explanation    'There is an error when modifying channelized interface caps.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_CNTL_ERR Fatal Error: Failed to modify channelized interface caps. Reason: [chars]

Explanation    'There is an error when modifying channelized interface caps.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_LKP_ERR Fatal Error: Channelized caps definition file is missing. Reason: [chars]

Explanation    'The Channelized Caps definition file is missing. There may have a packaging issue or someone just accidently removed that file.'

Recommended Action    Please reload the corresponding Jacket Card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-CAP_LKP_ERR Fatal Error: Channelized caps definition file is missing. Reason: [chars]

Explanation    'The Channelized Caps definition file is missing. There may have a packaging issue or someone just accidently removed that file.'

Recommended Action    Please reload the corresponding Jacket Card. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-ECM_INIT_FAILED Failed during create ECM initialization, Err: [chars]

Explanation    'There is a software error when creating ECM connection.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-ECM_INIT_FAILED Failed during create ECM initialization, Err: [chars]

Explanation    'There is a software error when creating ECM connection.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-SET_CALLBACK_ERR Fatal Error: Setting call-back to IM failed. Reason: [chars]

Explanation    'There is a software error when trying to set call-back to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-SET_CALLBACK_ERR Fatal Error: Setting call-back to IM failed. Reason: [chars]

Explanation    'There is a software error when trying to set call-back to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-SVR_UBIND_ERR Fatal Error: Failed to unbind to IM. Reason: [chars]

Explanation    'There is a software error when trying to unbind to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-3-SVR_UBIND_ERR Fatal Error: Failed to unbind to IM. Reason: [chars]

Explanation    'There is a software error when trying to unbind to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-4-SVR_BIND_ERR Warning: Failed to bind to IM. Reason: [chars]

Explanation    'There is a software error when trying to bind to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-4-SVR_BIND_ERR Warning: Failed to bind to IM. Reason: [chars]

Explanation    'There is a software error when trying to bind to IM.'

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-7-IFH_ERR Warning: Wrong if-handle [hex] [chars]

Explanation    'Receive a message with wrong interface handle. This may be ignored.'

Recommended Action    Ignore

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-7-IFH_ERR Warning: Wrong if-handle [hex] [chars]

Explanation    'Receive a message with wrong interface handle. This may be ignored.'

Recommended Action    Ignore

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-7-IM_CALLBACK_ERR Warning: [chars] failed. Reason: [chars]

Explanation    'There is a software error when handling messages from IM.'

Recommended Action    Ignore

Error Message     
 
    
    
   

%L2-C_SHIM_PARTNER-7-IM_CALLBACK_ERR Warning: [chars] failed. Reason: [chars]

Explanation    'There is a software error when handling messages from IM.'

Recommended Action    Ignore

C12000_FR Messages

Error Message     
 
    
    
   

%L2-C12000_FR-3-SUBIF_COUNT FR Subinterface counter is not initialised

Explanation    Initialisation of subinterface counter in the shared memory failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CCL Messages

Error Message     
 
    
    
   

%L2-CCL-3-INIT_ERROR Initialization failed: ([chars]%s)

Explanation    The classification control list (ccl) DLL failed to initialize. This DLL does a generalization of an Access Control List to include matching on MQC match criteria like QOS group, MPLS EXP, etc. If the ccl DLL fails to initialize, the access control list cannot be programmed into the hardware. %s - indicates the reason for the initialization failure. %s - is the decoded error reason.

Recommended Action    The failure should be handled by the process that is loading the DLL. The calling process should retry the initialization. Collect all debug information if the DLL is continually failing: 'debug ccl ace error location 0/x/cpu0' 'debug ccl api detail location 0/x/cpu0'

CDP Messages

Error Message     
 
    
    
   

%L2-CDP-3-ERR_CONN Connection error on [chars]([pointer]): [chars]

Explanation    An error occurred on one of the event connections managed by CDP which CDP could not recover automatically.

Recommended Action    Try restarting CDP. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IM_ATTR_REGISTRATION Unable to register for duplex change notifications: [chars]

Explanation    CDP registration for duplex change notifications failed. This means that duplex information will be missing from outgoing CDP packets

Recommended Action    Try restarting CDP ('proc restart cdp location location'). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IM_CAPS_ADD Failed to add the CDP capsulation to interface [chars]: [chars]

Explanation    CDP could not install the CDP capsulation on the specified interface and hence it is not possible for CDP to send or receive any packets on this interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IM_CAPS_REMOVE Failed to remove the CDP capsulation on interface [chars]: [chars]

Explanation    CDP could not uninstall the CDP capsulation on the specified interface and hence CDP may be in an inconsistent state.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IM_MTU_REGISTER Failed to register for MTU size changes on interface [chars]: [chars]

Explanation    CDP failed to register with the interface manager for MTU size changes on this particular interface. This may cause problems sending CDP packets.

Recommended Action    Perform 'cdp disable', 'cdp enable' on the interface to try to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IM_STATE_REGISTER Failed to register for state changes on interface [chars]: [chars]

Explanation    CDP failed to register with the interface manager for state changes on this particular interface. This means CDP will be unable to track the state of the interface. CDP functionality may be impaired.

Recommended Action    Perform 'cdp disable', 'cdp enable' on the interface to try to recover. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_INTF_INIT Initialisation of CDP on interface [chars] failed: [chars].

Explanation    CDP is unable to run on the specified interface. It is likely that this is due to a lack of available resources.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Configuring 'cdp disable', 'cdp enable' on the interface, or restarting CDP on the affected node may recover the situation.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_INTF_STATS No CDP protocol statistics can be collected on [chars]: [chars]

Explanation    It was not possible to register for stats collection on the specified interface. The entry in the 'show interface name accounting' command is likely to be inaccurate for CDP packets.

Recommended Action    Try restarting CDP and the Statistics server process on this node. proc restart cdp location node proc restart statsd_server location node If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IPV4_ADDRESS_SCAN [chars]: Failed to scan the IPv4 addresses for this interface: [chars]. This means that IPv4 information will be missing from outgoing CDP packets

Explanation    A scan of the IPv4 addresses on this interface has failed. This means that IPv4 address information for this interface will not be included in outgoing CDP packets. The neighboring device will not see the IPv4 address information for this interface.

Recommended Action    Restarting CDP as the address consumer, or the ipv4_ma as the address provider on this node may rectify the problem. proc restart cdp location location of failure or proc restart ipv4_ma location location of failure

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IPV4_REGISTRATION Unable to register for IPv4 address notifications: [chars]. This means that IPv4 information will be missing from outgoing CDP packets.

Explanation    CDP registration with the IP address library has failed. This means that IPv4 address information for interfaces local to this node will not be included in outgoing CDP packets. The neighboring devices will not see the IPv4 address information for this router's interfaces.

Recommended Action    Restarting CDP as the address consumer, or the ipv4_ma as the address provider on this node may rectify the problem. proc restart cdp location location of failure or proc restart ipv4_ma location location of failure

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IPV6_ADDRESS_SCAN [chars]: Failed to scan the IPv6 addresses for this interface: [chars]. This means that IPv6 information will be missing from outgoing CDP packets

Explanation    A scan of the IPv6 addresses on this interface has failed. This means that IPv6 address information for this interface will not be included in outgoing CDP packets. The neighboring device will not see the IPv6 address information for this interface.

Recommended Action    Restarting CDP as the address consumer, or the ipv6_ma as the address provider on this node may rectify the problem. proc restart cdp location location of failure or proc restart ipv6_ma location location of failure

Error Message     
 
    
    
   

%L2-CDP-3-ERR_IPV6_REGISTRATION Unable to register for IPv6 address notifications: [chars]. This means that IPv6 information will be missing from outgoing CDP packets.

Explanation    CDP registration with the IP address library has failed. This means that IPv6 address information for interfaces local to this node will not be included in outgoing CDP packets. The neighboring devices will not see the IPv6 address information for this router's interfaces.

Recommended Action    Restarting CDP as the address consumer, or the ipv6_ma as the address provider on this node may rectify the problem. proc restart cdp location location of failure or proc restart ipv6_ma location location of failure

Error Message     
 
    
    
   

%L2-CDP-3-ERR_STATS No per-interface CDP protocol statistics can be collected: [chars]

Explanation    It was not possible for CDP to register for per-interface CDP protocol stats collection. The entries in the 'show interface accounting' command are likely to be inaccurate for CDP packets.

Recommended Action    Try restarting CDP and the Statistics server process on this node. proc restart cdp location node proc restart statsd_server location node If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-3-STALE_TLV On [chars] the [chars] TLV is not up to date: [chars]

Explanation    CDP received a notification to update a TLV that it sends but failed to do so due to the error given. The information stored by CDP is now out of date.

Recommended Action    Perform 'cdp disable', 'cdp enable' on the interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-4-DUPLEX_MISMATCH Duplex mismatch discovered on [chars] ([chars]), with [chars] [chars] ([chars]).

Explanation    CDP discovered mismatching duplex configuration on neighboring interfaces.

Recommended Action    Configure the interfaces with the same duplex (full or half).

Error Message     
 
    
    
   

%L2-CDP-4-ERR_MULTICAST_ADDR_SET Error setting up the CDP multicast address on [chars] (media [chars]): [chars]

Explanation    The driver returned an error while setting up the CDP multicast address. It is possible that CDP packets will be dropped and not reach the CDP process.

Recommended Action    If CDP packet loss is seen then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-4-ERR_TABLE_RESIZE Not enough memory to clear and resize the CDP table

Explanation    CDP ran out of memory when trying to resize the CDP hash table.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. CDP will try and continue to use the previous CDP table.

Error Message     
 
    
    
   

%L2-CDP-4-NEIGHBOR_LIMIT The CDP cache on this node is full. It contains [dec] neighbor entries

Explanation    The limit for neighbors in the CDP cache has been reached. No more neighbors will be added to the neighbor cache until some existing entries have been removed. The number of entries is limited to defend against DoS attacks.

Recommended Action    Check the existing CDP neighbors for bogus entries, CDP may be the victim of an attempted DoS attack. The 'clear cdp table' command can be used if CDP neighbor entries need removing.

Error Message     
 
    
    
   

%L2-CDP-4-NO_KNOWN_MEDIA CDP did not find any recognized media to run over

Explanation    CDP failed to initialize the media module because it could not find any media that it recognizes. This may be a normal situation if CDP does not support the interface types on this node. In other circumstances CDP should recover automatically by restarting.

Recommended Action    If there are no interfaces on this node with a media type that CDP is expected to run on then this could be a normal condition. If it is expected that CDP should run on the type of interfaces on this node then Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-4-NO_KNOWN_MEDIA_DRIVERS CDP did not find any recognized media drivers

Explanation    CDP failed to initialize the media module because it could not find any media drivers that it recognizes. This may be a normal situation if CDP does not support the interface types on this node. In other circumstances CDP should recover automatically by restarting.

Recommended Action    There are no media drivers for the interfaces on this node. If CDP does not support the interface types on this node then this could be a normal situation Otherwise Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-4-WARN_INIT Initialization warning, module: [chars], operation: [chars]: [chars]

Explanation    A failure occurred during the initialization of CDP. CDP will restart and this should resolve the problem.

Recommended Action    CDP will try to recover automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-4-WARN_TERM Termination warning, module: [chars], operation: [chars]: [chars]

Explanation    A failure occurred during CDP's termination. In this situation CDP should recover automatically.

Recommended Action    CDP should recover automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CDP-6-DELETED_NEIGHBOR CDP Neighbour [chars] on interface [chars] has been deleted, remote interface [chars]

Explanation    An entry has been removed from the CDP neighbors table. Notification of deleted CDP neighbors requested through 'cdp log adjacency changes'.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-CDP-6-NEW_NEIGHBOR New CDP neighbor [chars] detected on interface [chars], remote interface [chars]

Explanation    A new entry has been added to the CDP neighbors table. Notification of new CDP neighbors requested through 'cdp log adjacency changes'.

Recommended Action    No action is required.

CEMA Messages

Error Message     
 
    
    
   

%L2-CEMA-3-FATAL_ERR CEMA Fatal Error: [chars]

Explanation    An internal fatal error was detected in CEMA module operation

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CEMA-3-MISMATCH_ERR CEMA Mismatch Error: [chars]

Explanation    A process on the line card that manages a SPA was restarted. As a part of restart, a mismatch was detected between user specified configuration and the actual configuration of SPA hardware.

Recommended Action    The mismatch can be service affecting in certain cases. Please check if the entity specified in the error log and all it's children are functioning correctly. Contact Cisco TAC for further assistance.

Error Message     
 
    
    
   

%L2-CEMA-4-GEN_ERR CEMA Internal Error: [chars]

Explanation    An internal error was detected in CEMA module operation

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CFM Messages

Error Message     
 
    
    
   

%L2-CFM-4-ERR_CONFIG Unsupported CFM config detected on interface handle [hex]. Total packets dropped [dec]

Explanation    Ethernet OAM CCMs are configured for an Layer 2 VPN interface over an unsupported pseudowire encapuslation

Recommended Action    Ethernet OAM CCMs upward MEP/MIP configuration is not supported for VPLS/L2TPv3 based L2VPN Attachment Circuits. Please review ethernet CFM configuration attached to the L2VPN interfaces and remove the unsupported Ethernet CFM upward MEP/MIP configuration.

CFMMIB Messages

Error Message     
 
    
    
   

%L2-CFMMIB-3-NO_DEBUG Unable to register for DOT1AG MIB debug. No further debugging will occur: [chars]

Explanation    In the initialisation of the DOT1AG MIB DLL an error occurred whilst attempting to register for debugging. Consequently there will be no debug output from the DOT1AG MIB DLL.

Recommended Action    Continue working with the DOT1AG MIB DLL without any debugging taking place or restart the DLL such that during initialisation there is another attempt register for debugging.

Error Message     
 
    
    
   

%L2-CFMMIB-3-NO_TRAP Unable to register for SNMP traps. Traps will not be sent regardless of trap events occurring: [chars]

Explanation    In the initialisation of the DOT1AG MIB DLL an error occurred whilst trying to register a callback function for the enabling of SNMP traps. Alternatively whilst trying to enable traps there was a failure in binding to SysDB for trap notifications.

Recommended Action    Continue working with the DOT1AG MIB DLL without any the ability to send traps when events occur or restart the DLL such that there is another attempt to register for traps.

CHDLC_EA Messages

Error Message     
 
    
    
   

%L2-CHDLC_EA-4-ERR_EVM_EVENT_BLOCK Error receiving an event: [chars]. The cHDLC EA process will restart

Explanation    An error occured in the event loop. The process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_EA-4-ERR_INIT Failure during initialization of the [chars]. Error [chars]. The cHDLC EA process will restart

Explanation    A failure occured during the initialization of the process. The process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_EA-6-ERR_IMP_MULTIPLE_NTFCNS CH[hex]: Multiple [chars] notifications received in a single batch from improxy

Explanation    A batch from IMProxy contained multiple notifications for a single interface. This should not occur but the situation has been recovered successfully by the cHDLC EA. No problems should be seen as a result.

Recommended Action    *NONE*

CHDLC_MA Messages

Error Message     
 
    
    
   

%L2-CHDLC_MA-3-ERR_IIR_BDL_OP The cHDLC MA failed to process a bundle IIR [chars] message on CH[hex], error: [chars]

Explanation    The chdlc_ma process failed to process a bundle IIR notification message. Further it is not able to propagate the message back to the virtual interface owner, and hence it is possible that the basecaps is out of step with the bundle configuration.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%L2-CHDLC_MA-3-ERR_INTF_UP_DOWN An error has occured resulting in the interface state being UP, and the line state being DOWN on interface CH[hex]. Because keepalives are disabled the line will never come up. The situation may be resolved by shutting and no shutting the interface, or enabling keepalives.

Explanation    If keepalives are disabled and certain errors occur then the interface and line state can end up being out of step. Without keepalives enabled, SLARP has no way to recover by discovering the correct line state, so user intervention is required for a chance of recovery.

Recommended Action    shut and then no shut the problematic interface, or enable keepalives on the interface.

Error Message     
 
    
    
   

%L2-CHDLC_MA-3-ERR_SYSMGR_SOCK_FEAT_START Startup of the cHDLC Socket feature has unexpectedly failed: [chars]

Explanation    The cHDLC socket feature unexpectedly failed to be started by sysmgr. This may mean that processes which use cHDLC sockets to send and receive packets will be unable to do so, and may not be working correctly. Symptoms would include loss of SLARP keepalive packets causing the line state to go down, loss of CDP packets and loss of LACP packets on cHDLC encapsulated interfaces.

Recommended Action    The problem can be fixed by manually starting the cHDLC Socket server process on the affected node using the command 'process start chdlc_socket location location'. The command 'show process chdlc_socket location location' will indicate the state of the process. Once the socket server process is running, no further action is required.

Error Message     
 
    
    
   

%L2-CHDLC_MA-4-ERR_EVM_EVENT_BLOCK Error receiving an event: [chars]. The cHDLC MA process will restart

Explanation    An error occured in the event loop.The process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_MA-4-ERR_INIT Failure during initialization of the [chars]. Error [chars]. The process will restart

Explanation    A failure occured during the initialization of the process. The cHDLC MA process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_MA-4-ERR_PKT_API_HANDLER Failure during the handling of an event received from the packet thread in [chars]: [chars].

Explanation    A failure occured whilst handling an event received from the packet thread.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_MA-4-ERR_PKT_HANDLER Failure during the handling of a packet event in [chars]: [chars].

Explanation    A failure occured whilst handling a packet event.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_MA-4-ERR_THREAD Failure during a cross thread operation in [chars]: [chars].

Explanation    A failure occured during thread handling.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_MA-6-ERR_IM_MULTIPLE_NTFCNS CH[hex]: Multiple [chars] notifications received in a single batch from Interface Manager

Explanation    A batch from Interface Manager contained multiple notifications for a single interface. This should not occur but the situation has been recovered successfully by the cHDLC MA. No problems should be seen as a result.

Recommended Action    *NONE*

CHDLC_SOCK Messages

Error Message     
 
    
    
   

%L2-CHDLC_SOCK-4-ERR_EVM_EVENT_BLOCK Error receiving an event: [chars]. The cHDLC socket server process will restart

Explanation    An error occured in the event loop. The process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_SOCK-4-ERR_INIT Failure during intialisation of the chdlc_socket process - specifically [chars]. Error: [chars]. The process will restart

Explanation    A failure occurred during the initialisation of the cHDLC socket process. The process will restart which should recover the situation.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHDLC_SOCK-4-ERR_PAKMAN_CORRUPTION Unable to handle pakman corruption error: [chars]. chdlc_socket process restarting

Explanation    A packet manager corruption has been reported and the cHDLC Socket process has failed to cleanup to recover from the problem. The process will exit and be automatically restarted to recover from this situation.

Recommended Action    It is expected that restarting the process will fix this problem. This is done automatically so no action should be required. If the problem recurs, then there is a problem in packet manager. A drastic solution would be to reload the linecard.

CHDLCDLL Messages

Error Message     
 
    
    
   

%L2-CHDLCDLL-3-ERR_DEBUG_REGISTER Could not register for debug events : [chars]

Explanation    There was an error registering the cHDLC Netio debug with the debug library. No debug will be available for the cHDLC Netio DLLs.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%L2-CHDLCDLL-3-ERR_PKT_ENCAP Encapsulation of HDLC packet failed. Packet type-code [hex]

Explanation    The encapsulation of an HDLC packet failed for the network protocol with the ethernet type code specified. The packet has been dropped.

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%L2-CHDLCDLL-3-ERR_TRACE_REGISTER Could not register with tracing infrastructure: [chars]

Explanation    An attempt to register with the tracing infrastructure failed. This will mean that tracing for the cHDLC Netio DLLs will not be available.

Recommended Action    *SUPPORT*

CHIPs Messages

Error Message     
 
    
    
   

%L2-CHIPs-2-error [chars]

Explanation    A high severity error has occurred in PLIM FPGA. This might result in the PLIM being reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CHNLZD_EFCM Messages

Error Message     
 
    
    
   

%L2-CHNLZD_EFCM-3-ERROR_CFG_BUFF Err: [chars]

Explanation    An error has occurred in the Extended Flow Control Manager. EFCM was unable to open or map shared memory for debug.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHNLZD_EFCM-3-ERROR_COMM_ERR Err: [chars]

Explanation    An error has occurred in the Extended Flow Control Manager. An attempt to set an entry in the Flow Control calendar failed. This error indicates that messaging between the SPA process and the Jacket process failed in XR.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHNLZD_EFCM-3-ERROR_EINVAL Err: [chars]

Explanation    An error has occurred in the Extended Flow Control Manager. This is caused by an out of bounds Flow Control channel number or bay number trying to be used during the configuration of Flow Control for the SPA.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHNLZD_EFCM-3-ERROR_NOIFH Err: [chars]

Explanation    An error has occurred in the Extended Flow Control Manager. While removing Flow Control information, the calling function failed to provide an interface handle.

Recommended Action    *RECUR*

Error Message     
 
    
    
   

%L2-CHNLZD_EFCM-6-INFO Info: [chars]

Explanation    Extended Flow Control Manager(EFCM) informative message. This message is used to provide information regarding the configuration (internal only) of Flow Control for channelized SPAs.

Recommended Action    *RECUR*

COMMS Messages

Error Message     
 
    
    
   

%L2-COMMS-3-MSG_DROPPED Unexpected error has lead to an incoming message being dropped: [chars]

Explanation    An incoming control message could not be fully processed due to an unexpected error.

Recommended Action    Restarting the process in question should result in a full resync of all data. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-COMMS-3-MY_ID_MISMATCH Checkpoint data for this connection (id %hu) has invalid id (%hu)

Explanation    The Checkpoint table contained unexpected data. This is unexpected, and could indicate memory corruption of some sort.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-COMMS-3-MY_SAVE_FAILED Failed to save Checkpoint sequence information for connection [chars]

Explanation    The client failed to save its own sequence data to Checkpoint. If the process restarts before the save is successfully retried, remote clients may get out of sync, and data loss could occur.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-COMMS-3-SAVE_FAILED Failed to save Checkpoint entry [hex]/[hex] on connection [chars]

Explanation    The client failed to save data to Checkpoint. If the process restarts before the save can be retried, then data loss could occur.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-COMMS-4-DUPLICATE_ENTRY Duplicate Checkpoint entry for ID %hu on node [hex]

Explanation    The Checkpoint table contained a duplicate entry. This is unexpected, and likely indicates a software fault.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPP_ACL_EA Messages

Error Message     
 
    
    
   

%L2-CPP_ACL_EA-3-INIT Failed to initialize [chars], because of [chars]

Explanation    Initialization process such as getting an evm failed.

Recommended Action    sysmgr will retry to start the cpp_acl_ea. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

CPP_EXMEM Messages

Error Message     
 
    
    
   

%L2-CPP_EXMEM-3-FATAL_ERROR [chars]: [chars]

Explanation    A fatal error occurred in CPP external memory manager which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_EXMEM-6-THRESHOLD_CLEAR CPP [dec] [chars] memory recovered - [dec] percent depleted

Explanation    Exmem resource cross under its threshold

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_EXMEM-6-THRESHOLD_DECLARE CPP [dec] [chars] memory low - [dec] percent depleted

Explanation    Exmem resource cross over its threshold

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_EXMEM-7-DEBUG_MSG [chars]

Explanation    This is a debug message

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPP_FM Messages

Error Message     
 
    
    
   

%L2-CPP_FM-6-FIELD_IGNORED Matching on field type [unsigned int] ([chars] value [unsigned int] ([hex])) not supported for client [chars] ([unsigned int]), rule oid: [chars], seqnos: [unsigned long long int], [unsigned long long int], [unsigned long long int]: RULE *IGNORED*

Explanation    User is trying to use a classification criterion not supported by the feature. For example, user is trying to apply a with a class matching matched on an IPv6 ACL that contains a match on flow-label. The entire rule (e.g. ACE) containing the unsupported criterion is ignored. In our example, only the ACEs containing match on flow label are ignored. All other ACEs are still downloaded to CPP.

Recommended Action    No action is required.

cpp_ifm Messages

Error Message     
 
    
    
   

%L2-cpp_ifm-3-FATAL_ERR Fatal error: [chars]: ErrCode equals [dec]

Explanation    A fatal error occurred in the CPP IFM Library.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cpp_ifm-3-WARN_ERR Warning: [chars]: ErrCode equals [dec]

Explanation    A non-fatal condition occured in the CPP IFM Library that may affect the functionality of CPP.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPP_LPTS_EA Messages

Error Message     
 
    
    
   

%L2-CPP_LPTS_EA-3-INIT Failed to initialize [chars], because of [chars]

Explanation    Initialization process such as getting an evm failed.

Recommended Action    sysmgr will retry to start the cpp_lpts_ea. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

CPP_MDM Messages

Error Message     
 
    
    
   

%L2-CPP_MDM-3-FATAL_ERR [chars]: Err equals [hex]

Explanation    A fatal error occurred in CPP Infra Metadata Mgr which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_MDM-7-DEBUG_MSG [chars]

Explanation    This is a debug message

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPP_PFILTER_EA Messages

Error Message     
 
    
    
   

%L2-CPP_PFILTER_EA-3-MSG_SEND_FAILED cpp_pfilter_ea: msg: [dec], retried: [dec] time(s), failed to send, errno: [chars]

Explanation    Unable to send a message to the CPP Pfilter EA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

cpp_sbs Messages

Error Message     
 
    
    
   

%L2-cpp_sbs-3-FATAL_ERR [chars]: Err equals [hex]

Explanation    A fatal error occurred in CPP Infra Stats Block Service which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cpp_sbs-3-FATAL_ERR [chars]: Err equals [hex]

Explanation    A fatal error occurred in CPP Infra Stats Block Service which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPP_TCAM_RM Messages

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-3-FATAL_ERR Fatal error: [chars]: Err equals [dec]

Explanation    A fatal error occurred in CPP TCAM RM which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-3-MSG_SEND_FAILED cpp_tcam_rm: msg: [dec], retried: [dec] time(s), failed to send, errno: [chars]

Explanation    Unable to send a message to the CPP TCAM RM server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-3-NONFATAL_ERR Nonfatal error: [chars]: Err equals [dec]

Explanation    This is a error message in the CPP TCAM RM to indicate anomalies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temporary situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-6-HIGH_WATER_MARK CPP [dec] TCAM resources in the system is limited.

Explanation    The TCAM device has limited number of free cells left to allocate.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-6-INFO_MSG Info: [chars]

Explanation    This is an informational message in the CPP TCAM RM.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-CPP_TCAM_RM-6-LOW_WATER_MARK CPP [dec] TCAM resource is sufficient.

Explanation    The TCAM device has sufficient number of free cells left.

Recommended Action    No action is required.

CPP_UIDB Messages

Error Message     
 
    
    
   

%L2-CPP_UIDB-3-FATAL_ERROR [chars]: [chars]

Explanation    A fatal error occurred in uidb manager which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPP_UIDB-7-DEBUG_MSG [chars]

Explanation    This is a debug message

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPPBQS Messages

Error Message     
 
    
    
   

%L2-CPPBQS-6-SRTMEMLOW_CLEAR CPP [dec] HW [chars]:[chars] schedule resources recover from depletion - [dec]% available

Explanation    CPP BQS HW schedule resources have recovered from critical threshold.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPBQS-6-SRTMEMLOW_DECLARE CPP [dec] HW [chars]:[chars] schedule resources depleted - [dec]% available

Explanation    CPP BQS HW schedule resources have dropped below critical threshold.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

cppdrv Messages

Error Message     
 
    
    
   

%L2-cppdrv-2-HALT [chars]([dec]) Interrupt : [chars] Seq:[dec] Halt bit set.

Explanation    A Serious CPP hardware error has occurred.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-ALLOCATE_NOTIFY CPP[dec]: Failed to allocate data: ([chars]).

Explanation    A function failed to allocate data.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-CLEANUP_NOTIFY Failed to cleanup data: ([chars]).

Explanation    A function failed to cleanup data.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-DESTROY_NOTIFY Failed to destroy connection: ([chars]).

Explanation    A function failed to destroy a connection.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_ACQUIRE_LOCK ([hex]) Failed to acquire memory lock - [chars].

Explanation    Driver SW failed to acquire shared memory lock.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_ATTACH CPP[dec]: ([hex]) - Failed to attach [chars].

Explanation    Device Failed to attach.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_CREATE CPP[dec]: ([hex]) - Failed to create [chars] - [chars].

Explanation    Driver failed to get device details.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_ERR Fatal error: [chars]: ErrCode equals [dec]

Explanation    A fatal error occurred in CPP Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_GET_DETAILS CPP[dec]: ([hex]) - Failed to get device details - [chars].

Explanation    Driver failed to get device details.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_INIT CPP[dec]: ([hex]) - Failed to initialize [chars] - [chars].

Explanation    Driver failed to initialize a device.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_INTERNAL CPP[dec]: ([hex]) Failed: internal SW error- [chars].

Explanation    Driver failed to initialize a device.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_MEM_CLEAR CPP[dec]: ([hex]) Failed to clear memory - [chars].

Explanation    Driver failed to clear memory.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_MEM_SIZE CPP[dec]: ([hex]) Failed to acquire memory size - [chars].

Explanation    Driver SW failed to acquire the size of a block of memory.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_MEM_WRITE CPP[dec]: ([hex]) Failed to write to memory [chars].

Explanation    Driver failed to write to memory.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_PLAT_DB CPP[dec]: ([hex]) - Platform failure accessing [chars].

Explanation    Platform DB query failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_RELEASE_LOCK ([hex]) Failed to release memory lock - [chars]

Explanation    Driver SW failed to release shared memory lock.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-FATAL_UNSUPPORT CPP[dec]: ([hex]) Unsupported CPP type: CPP TYPE:[dec]

Explanation    Unsupported CPP TYPE.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-HOT [chars]([dec]) Interrupt : [chars] Seq:[dec] repeating interrupt has been disabled.

Explanation    A repeating hardware interrupt has been disabled.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-INIT_NOTIFY Failed to initialize: ([chars]).

Explanation    A function failed to initialize.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-INIT_NOTIFY_ID CPP[dec]: Failed to initialize: ([chars]).

Explanation    A function failed to initialize.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-LOCKDOWN [chars]([dec]) CPP Driver LOCKDOWN due to fatal error.

Explanation    A fatal error has caused the driver to LOCKDOWN.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-TCAM_PERR [chars]([dec]) TCAM Parity error TCAM device #[dec] at offset [hex].

Explanation    A Parity error has occurred in a TCAM device.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-TCAM_PERR_FAILURE [chars]([dec]) Failed to correct TCAM Parity error. Parity error detection disabled.

Explanation    Failed to correct a TCAM Parity error and further detection has been disabled.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-3-WARN_ERR Warning: [chars]: ErrCode equals [dec]

Explanation    A non-fatal condition occurred in the CPP driver that may affect the functionality of CPP.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-4-ADRSPC_LIMIT Address space limit [unsigned int] KB reached, mapping block [chars] size [unsigned int] dynamically, over limit space: [unsigned int] KB

Explanation    The process indicated tried to map more of the Forwarding Engine's address space than was allocated for it. A slower access method will be used instead. This will lower the performance of some operations which require accesses to the Forwarding Engine

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cppdrv-6-ACCTRC128B Access CPP [dec] address [hex] (Blk/Off:[dec]/[hex]) [chars] [dec] bytes [hex]_[hex] flags [hex]

Explanation    A CPP access was traced

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-cppdrv-6-ACCTRC64B Access CPP [dec] address [hex] (Blk/Off:[dec]/[hex]) [chars] [dec] bytes [hex] flags [hex]

Explanation    A CPP access was traced

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-cppdrv-6-INTR [chars]([dec]) Interrupt: [chars]

Explanation    A CPP hardware interrupt has occurred.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

CPPHA Messages

Error Message     
 
    
    
   

%L2-CPPHA-3-CDMDONE CPP [dec] microcode crashdump creation completed

Explanation    CDM has completed crashdump creation.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-FAILURE CPP [dec] failure [chars] detected

Explanation    A CPP failure has been detected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-FAULT CPP [dec] fault:[chars] det:[chars] class:[chars] sev:[chars] idx:[dec] cppstate:[chars] res:[chars] flags:[hex] cdmflags:[hex]

Explanation    A CPP failure has been detected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-FAULTCRASH CPP [dec] unresolved fault detected, initiating crash dump.

Explanation    A CPP failure has been detected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-FAULTRATE CPP [dec] fault:[chars] det:[chars] class:[chars] sev:[chars] idx:[dec] cppstate:[chars] res:[chars] flags:[hex] cdmflags:[hex]

Explanation    A CPP fault has occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-INITFAIL CPP [dec] initialization failed - [chars] ([hex])

Explanation    A CPP initialization failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-CPPHA-3-NOCDM CPP [dec] CDM not running.

Explanation    A CPP failure has been detected.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

cpposlib Messages

Error Message     
 
    
    
   

%L2-cpposlib-3-CLEAN_NOTIFY Failed to cleanup: ([chars]).

Explanation    A function failed to cleanup.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cpposlib-3-ERROR_NOTIFY [chars] encountered an error

Explanation    A process encountered error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-cpposlib-3-INIT_NOTIFY Failed to initialize: ([chars]).

Explanation    A function failed to initialize.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

d1qnetio Messages

Error Message     
 
    
    
   

%L2-d1qnetio-3-CHAIN_BUILDER_FAILED The chain build function failed because '[chars]' (error: [chars])

Explanation    The software forwarding support for IEEE802.1Q VLANs was unable to set up an interface. Software forwarding VLAN functionality on the affected node may be impaired.

Recommended Action    It may help to restart the VLAN EA process on the affected node, with process restart vlan_ea location [location]. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-3-IDB_NOT_FOUND The Netio IDB associated with handle [hex] could not be found

Explanation    The software forwarding support for IEEE802.1Q VLANs was unable to process a message sent to a particular interface because the interface does not exist in NetIO. Software forwarding VLAN functionality on the affected interface may be impaired. The interface can be determined from its handle with show im chains ifhandle [handle].

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-3-REGISTRY_CREATION_FAILED Unable to create the protocol registries during capsulation initialization

Explanation    The 802.1Q NetIO component could not necessary data structures during its initialization. Software forwarding VLAN functionality on the affected is likely not to work.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-3-SUBBLOCK_REG_FAILED 802.1Q Netio failed to register the dot1q_ether subblock (error: [chars])

Explanation    The software forwarding support for IEEE802.1Q VLANs was unable to initialise on the specified node. Software forwarding VLAN functionality on the affected is likely not to work.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-3-TRACE_INIT_ERROR A error occurred during trace initialization, err: [chars]

Explanation    The 802.1Q NetIO component encoutered an error during trace buffer initialization. This is likely to cause VLAN interface setup to fail.

Recommended Action    If this error occurred as a result of applying configuration, try removing and reapplying the configuration. If this does not work, it may be necessary to reload the affected linecard. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-4-CHAIN_UNBUILDER_FAILED The chain unbuild function failed because '[chars]' (error: [chars])

Explanation    The software forwarding support for IEEE802.1Q VLANs was unable to clean up an interface. Forwarding should not be affected.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-4-DEBUG_INIT_ERROR An error occurred during debug initialization (error: [chars])

Explanation    The 802.1Q NetIO component encoutered an error during debug initialization. This is likely to cause VLAN interface setup to fail.

Recommended Action    If this error occurred as a result of applying configuration, try removing and reapplying the configuration. If this does not work, it may be necessary to reload the affected linecard. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-4-DEVCTL_NOT_SUP Unsupported NetIO devctl code ([dec]) received

Explanation    The 802.1Q NetIO component received an unexpected message. The message has been ignored. This may indicate that there is a version mismatch among the VLAN components.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-d1qnetio-4-TERM_FAILED 802.1Q NetIO termination failed because '[chars]' (error: [chars])

Explanation    The software forwarding support for IEEE802.1Q VLANs was unable to clean up. Forwarding should not be affected.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

DI Messages

Error Message     
 
    
    
   

%L2-DI-3-CHANNELCREATE unable to create channel [chars] (Error code [int])

Explanation    Process failed to create communication channel and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-CHKPT unable to create checkpoint service.

Explanation    Process failed to create checkpoint service and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-COMMAND Three command line parameters required: depository_id promid (0/1/2/3)

Explanation    Process received wrong third command line parameter and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-COMMAND3 Third command line parameter is [unsigned long int].It must be 0/1/2/3.

Explanation    Process received wrong third command line parameter and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-CONNECTION Unable to connect to channel [chars] (Error code [int])

Explanation    Process failed to connect to communication channel and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DESTINSANE Data structure destination organizer [chars] is inconsistent for destination [unsigned long int].

Explanation    Process detected inconsistent data structures and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DESTORG unable to create destination organizer.

Explanation    Process failed to create destination organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DIDORG unable to create DID organizer.

Explanation    Process failed to create DID organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DLLABSENT Driver DLL [chars] is absent on the platform.

Explanation    A specific driver DLL is required to run certain hardware detected.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DLLORG unable to create DLL organizer.

Explanation    Process failed to create DLL organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-DLLSYMMISSING Driver DLL [chars] has missing symbol [chars].

Explanation    A specific driver DLL is not correct.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-ENTRY One of the drivers unable to init.

Explanation    Process unable to init one of the drivers and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-ERRORG unable to create error organizer.

Explanation    Process failed to create error organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-EVE Failed to init event manager event.

Explanation    Process failed to create event manager event and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-EVELOOP IM notify event manager loop exited (Error no equals [unsigned long int]).

Explanation    Process terminated event manager loop and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-EVEMGR Failed to create event manager.

Explanation    Process failed to create event manager and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-INCONSISTINSTHASH Data structure Instance Hash is inconsistent for instance id [unsigned long int].

Explanation    Process detected inconsistent data structures and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-INCONSISTRSRCHASH Data structure Resource Hash is inconsistent for resource id [unsigned long int].

Explanation    Process detected inconsistent data structures and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-INSTHASH unable to create instance hash.

Explanation    Process failed to create instance hash and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-INSTSTORE unable to create instance persistence store.

Explanation    Process failed to create instance persistence store and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-INTORG unable to create interrupt organizer.

Explanation    Process failed to create interrupt organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-MAINLINE Unable to create mainline ipc server.

Explanation    Process unable to create mainline ipc server and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-MUTEXINIT Mutex initialization error [chars] (Error code [int])

Explanation    Process failed to initialize a mutex and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-MUTEXLOCKFAIL [chars] operation failed in [chars]; reason [chars]

Explanation    DI failed to lock the packet mutex.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DI-3-NETIOEST NetIO failed to connect to driver_infra_partner and exiting..

Explanation    The initial set up between two driver processes failed. NetIO exiting.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-OUTMEM malloc ([unsigned long int] bytes) from::[chars] failed.

Explanation    Process failed to allocate run-time memory and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-PEERSTORE unable to create peer persistence store.

Explanation    Process failed to create peer persistence store and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-REGOMISSING No installed software to match Hardware in slot [unsigned long int] (PROMID [unsigned long int]).

Explanation    Report missing driver registration.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-REGOMISSING1 No installed software to match Hardware in I/O slot in route-processor [unsigned long int] (PROMID [unsigned long int]).

Explanation    Report missing driver registration.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-REGOORG unable to create registration organizer.

Explanation    Process failed to create registration organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-RESIDORG unable to create RESID organizer.

Explanation    Process failed to create RESID organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-RESOURCEHASH unable to create resource hash.

Explanation    Process failed to create resource hash and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-SHMWIN failed to reserve the shmwin VM region.

Explanation    Process failed to reserve the shmwin VM region and hence exiting.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-STARTCHKPT unable to start checkpoint service.

Explanation    Process failed to start checkpoint service and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-STARTDESTORG unable to start destination organizer.

Explanation    Process failed to start destination organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-SYNHORG unable to create synchronizer organizer.

Explanation    Process failed to create synchronizer organizer and hence terminating.

Recommended Action    'No action is required.'

Error Message     
 
    
    
   

%L2-DI-3-THREADCREATE Unable to create thread [chars] (Error code [int])

Explanation    Process failed to create thread and hence terminating.

Recommended Action    'No action is required.'

DIV2_DM Messages

Error Message     
 
    
    
   

%L2-DIV2_DM-3-INFO driver manager: service degrading error, reason equals [chars]

Explanation    Driver manager encountered an error that would lead to degraded service.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DIV2_DM-3-INIT Driver manager: init. error encountered, reason equals [chars]

Explanation    Driver manager encountered an error and is not able recover frm it. A reason text will be supplied. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DIV2_DM-3-NO_MEM Driver manager: memory allocation error for [dec] bytes

Explanation    Driver manager encountered a fatal memory allocation error

Recommended Action    Reduce other system activity (e.g. by killing non-essential processes) to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

DRIVERS_UTIL Messages

Error Message     
 
    
    
   

%L2-DRIVERS_UTIL-3-TUPLE_READ_ERROR [chars]: Tuple read failed with error [hex] [chars]

Explanation    An error occured when trying to read the tuple from sysdb.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

DWDM Messages

Error Message     
 
    
    
   

%L2-DWDM-3-FATAL dwdm: fatal error encountered, reason equals [chars]

Explanation    dwdm encountered a fatal error and is not able recover from the error. A reason text will be supplied call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DWDM-3-FATAL_2 dwdm: fatal error encountered, reason equals [chars], errno equals [dec]

Explanation    dwdm code encountered a fatal error and is not able to recover from the error. A reason text will be supplied call support with this text. An integer errno will also be printed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DWDM-3-INFO dwdm: service degrading error, reason equals [chars]

Explanation    The dwdm encountered an error that would lead to degraded service.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DWDM-3-NOT_YET_IMPLEMENTED dwdm: this function [chars] is not yet implemented

Explanation    dwdm, a function was not implemented.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-DWDM-4-FORCED_MAINTENANCE dwdm: Port : [chars], Forced Maintenance: [chars], Reason: [chars]

Explanation    If this alarm is on, that means that the port is put into OOS-MT (maintenance) state despite the maintenance-embargo flag for this port being TRUE. If it is off, that means there is no Forced Maintenance.

Recommended Action    A forced maintenance activity implies that there may be loss of traffic. A port should not be put into OOS-MT (maintenance) state if its embargo flag is TRUE, unless absolutely necessary.

Error Message     
 
    
    
   

%L2-DWDM-5-EMBARGO_ENABLED dwdm: Port : [chars], Embargo Enabled : [dec]

Explanation    If this alarm is on, that means that the maintenance-embargo flag is enabled. This implies maintenace activity is not allowed unless forced.

Recommended Action    This maintenance flag can be disabled on tenGigE or POS interface corresponding to dwdm port.

Error Message     
 
    
    
   

%L2-DWDM-5-SRLG_OVERFLOW DWDM: Port id: [chars], Overflow of SRLGs: [chars]

Explanation    We support 100 SRLGs per DWDM port at the CRS. If some application like CTC has more than 100 values to configure, it indicates this situation by configuring the 101st value with a positive integer. If the 101st value is not configured, we understand that there is no overflow. This ios_msg logs this information in the logfile.

Recommended Action    Just be aware!

Error Message     
 
    
    
   

%L2-DWDM-6-CLEAR_COUNTERS Cleared counters on [chars]

Explanation    Counters on a dwdm controller has been cleared by the user. This message is for information only.

Recommended Action    None.

E3EGRESSQ Messages

Error Message     
 
    
    
   

%L2-E3EGRESSQ-3-ERR_MEM_ALLOC Failed to allocate [dec] bytes from [chars] ([chars])

Explanation    The process failed to allocate memory. Most likely, all system memory has been allocated already.

Recommended Action    Verify that the card has at least the minimum supported memory configuration. Use the 'show memory' and 'show processes memory location' commands to identify what processes use the memory. If memory usage for a process seems abnormal, restarting the process using the command 'process restart' could be a workaround. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-3-ERR_THREAD_MUTEX_LOCK Failed to lock mutex

Explanation    The process failed to obtain a software mutex lock. Software mutex are used to protect certain operations from being executed simultaneously by concurrent processes. This indicates a software error which could lead to data corruption and loss of traffic.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-3-ERR_THREAD_MUTEX_UNLOCK Failed to unlock mutex

Explanation    The process failed to obtain a software mutex unlock. Software mutex are used to protect certain operations from being executed simultaneously by concurrent processes. This indicates a software error which could lead to data corruption and loss of traffic.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-3-MEM_MAP [chars] (size [hex] addr [hex]) - [chars]

Explanation    The process could not map the egress asic SDRAM into its memory space.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-3-RECONFIG [chars]: error [hex]

Explanation    The egress queueing asic was reset, but could not be reconfigured. This may result in partial or complete loss of functionality of the asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_MEM_ALLOC_SHMWIN Failed to open shared memory window [chars] ([chars])

Explanation    The process failed to open the specified shared memory window. This problem can be caused by a lack of system memory.

Recommended Action    Verify that the card has at least the minimum supported memory configuration. Use the 'show memory' and 'show processes memory location' commands to identify what processes use the memory. If memory usage for a process seems abnormal, restarting the process using the command 'process restart' could be a workaround.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_MEM_FREE Failed to free [chars] ([chars])

Explanation    The process failed to free memory. This is likely a symptom of software corruption. The system may be in an unstable condition. The software failed to free memory, and this can eventually lead to an out-of-memory condition.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_MEM_MQS_COUNTER_THR_EXCEEDED MQS counter utilization [dec] exceeds the high threshold of [dec]

Explanation    The multicast counter utilization has exceeded the high threshold. This may impact the delay and/or jitter of multciast traffic egressing out of this line card. The maximum counters available are 2048.

Recommended Action    Reduce the multicast traffic rate sent to this line card.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_MUTEX_INIT Failed to [chars] ([chars])

Explanation    The process failed to initialize a software mutex. Software mutex are used to protect certain operations from being executed simultaneously by concurrent processes. This indicates a software error which could lead to eventual data corruption and loss of traffic.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_MUTEX_REVIVE Failed to register for mutex revival ([chars])

Explanation    The process failed to register for mutex revival. In the event of a software error where another process would crash while holding a shared mutex, this process would not self-recover. This warning does not cause any degradation in the router operation. The warning simply means that a particular error recovery mechanism will not be effective.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-ERR_PLATFORM_INFO Failed to obtain platform info for [chars] ([chars])

Explanation    The process failed to obtain information on the specified shared memory window. This will prevent proper initialization and operation multicast feature. This indicates a software error condition.

Recommended Action    Reload the linecard. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-4-INTERRUPT [chars]: reg [hex]

Explanation    The E3EGRESSQ asic experienced an interrupt, and will be reset. After reset, normal operation should resume.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3EGRESSQ-6-ERR_MEM_MQS_COUNTER_THR_NORMAL MQS counter utilization [dec] within the low threshold of [dec]

Explanation    The multicast counter utilization has eased off to below the low threshold.

Recommended Action    No action required.

E3INGRESSQ Messages

Error Message     
 
    
    
   

%L2-E3INGRESSQ-3-RECONFIG [chars]: error [hex]

Explanation    The ingress queueing asic was reset, but could not be reconfigured. This may result in partial or complete loss of functionality of the asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E3INGRESSQ-4-INTERRUPT [chars]: reg [hex]

Explanation    The E3INGRESSQ asic experienced an interrupt, and will be reset. After reset, normal operation should resume.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

E5EGRESSQ Messages

Error Message     
 
    
    
   

%L2-E5EGRESSQ-3-RECONFIG [chars]: error [hex]

Explanation    The egress queueing asic was reset, but could not be reconfigured. This may result in partial or complete loss of functionality of the asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E5EGRESSQ-4-ERR_MEM_MQS_COUNTER_THR_EXCEEDED MQS counter utilization [dec] exceeds the high threshold of [dec]

Explanation    The multicast counter utilization has exceeded the high threshold. This may impact the delay and/or jitter of multciast traffic egressing out of this line card. The maximum counters available are 16384.

Recommended Action    Reduce the multicast traffic rate sent to this line card.

Error Message     
 
    
    
   

%L2-E5EGRESSQ-4-ERROR [chars]: error [hex]

Explanation    The e5 egress queue driver encountered an internal error. The router may/may not continue to function normally.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E5EGRESSQ-4-INTERRUPT [chars]: reg [hex]

Explanation    The E5EGRESSQ asic experienced an interrupt, and will be reset. After reset, normal operation should resume.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E5EGRESSQ-6-ERR_MEM_MQS_COUNTER_THR_NORMAL MQS counter utilization [dec] within the low threshold of [dec]

Explanation    The multicast counter utilization has eased off to below the low threshold.

Recommended Action    No action required.

E5INGRESSQ Messages

Error Message     
 
    
    
   

%L2-E5INGRESSQ-3-RECONFIG [chars]: error [hex]

Explanation    The ingress queueing asic was reset, but could not be reconfigured. This may result in partial or complete loss of functionality of the asic.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-E5INGRESSQ-4-INTERRUPT [chars]: reg [hex]

Explanation    The E5INGRESSQ asic experienced an interrupt, and will be reset. After reset, normal operation should resume.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

edge_l2fwd_rewrite Messages

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-FM_ADD_FEAT_ERR [chars], Failed to add feature for [chars], err: [chars]

Explanation    edge_l2fwd_rewrite failed to add specific feature in FM.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-FM_DEL_FEAT_ERR [chars], Failed to del feature for [chars], err: [chars]

Explanation    edge_l2fwd_rewrite failed to delete specific feature in FM.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-FWD_MEMMGR_READ_ERR [chars], Failed to read [chars] from FWD MemMgr, err: [chars]

Explanation    edge_l2fwd_rewrite failed to read adj counters/PLU/TLU through FWD Memory manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-HFA_CREATE_ERR [chars],Failed to create gather index in HFA

Explanation    edge_l2fwd_rewrite failed to create gather index in HFA

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-HFA_PROG_ERR [chars],Failed to program [chars] ucast in HFA

Explanation    edge_l2fwd_rewrite failed to program feature specific ucast in HFA

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-HFA_REGISTER_ERR [chars],Unable to open connection with HFA

Explanation    edge_l2fwd_rewrite Connection open with the HFA failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-INSERT_ENCAP_STRING_ERR [chars], Insert encap string failed for Ifhandle equals [hex] err:[chars]

Explanation    edge_l2fwd_rewrite failed while removing the encap string

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-MEM_REG_ERR [chars], Error while registering with Forwarding Memory Manager

Explanation    edge_l2fwd_rewrite Registration with the forwarding Memmgr Failed !

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-PLU_FREE_ERR [chars],PLU free failed, error:[chars]

Explanation    edge_l2fwd_rewrite Failed to free PLU though the forwarding Memory Manager

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-PLU_MALLOC_ERR [chars], Failed to allocate memory for the PLU Leaf

Explanation    edge_l2fwd_rewrite Forwarding memory module failed to allocate memory for the PLU leaf

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-PLU_WRITE_ERR [chars],[dec],PLU write error:[chars]

Explanation    edge_l2fwd_rewrite Failed while writing into the PLU though the forwarding Memory Manager

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-REMOVE_ENCAP_STRING_ERR [chars], remove encap string failed OI equals [hex] err:[chars]

Explanation    edge_l2fwd_rewrite failed while removing the encap string

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-RM_INIT_ERR [chars], [dec] error, reason:[chars]

Explanation    edge_l2fwd_rewrite Encap Resource Manager Initialisation error

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-TLU_FREE_ERR [chars],TLU free error:[chars]

Explanation    edge_l2fwd_rewrite Failed to free TLU through forwarding Memory manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-TLU_MALLOC_ERR [chars], Failed to allocate memory for the TLU Leaf

Explanation    edge_l2fwd_rewrite Forwarding memory module failed to allocate memory for the TLU leaf

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-TLU_SIZE_ERR [chars], Invalid TLU write size, TLU size:[dec], Write Size:[dec]

Explanation    edge_l2fwd_rewrite failed to write to TLU as the write size is not less than the actual TLU size

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-TLU_WRITE_ERR [chars],[dec],TLU write error:[chars]

Explanation    edge_l2fwd_rewrite Failed while writing into the TLU though the forwarding Memory manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-UIDB_READ_ERR [chars],Uidb read failed - err: [chars]

Explanation    edge_l2fwd_rewrite Uidb read failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-UIDB_SET_ERR [chars],Uidb set failed for xconnid:[dec], err: [chars]

Explanation    edge_l2fwd_rewrite Uidb set failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-XBMA_ADD_ERR [chars], Failed to add mcast entry, err: [chars]

Explanation    edge_l2fwd_rewrite failed to add mcast entry in XBMA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-XBMA_CONN_ERR [chars], Failed to connect to XBMA server, err: [chars]

Explanation    edge_l2fwd_rewrite failed to connect to XBMA server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-XBMA_DEL_ERR [chars], Failed to del mcast entry, err: [chars]

Explanation    edge_l2fwd_rewrite failed to delete mcast entry in XBMA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_rewrite-2-XBMA_INIT_ERR [chars], Failed to initialize XBMA library, err: [chars]

Explanation    edge_l2fwd_rewrite failed to initialize XBMA lib.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

edge_l2fwd_table Messages

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_DEL_ERR [chars], Failed to delete [chars] for [chars] in FAD

Explanation    edge_l2fwd_table failed to delete l2fwd lookup entry in FAD

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_INIT_ERR [chars], Failed to initialize FAD, reason:[chars]

Explanation    edge_l2fwd_table FAD module failed to get initialized.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_INSERT_ERR [chars], Failed to insert lookup entry for [chars] in FAD

Explanation    edge_l2fwd_table failed to insert l2fwd lookup entry in FAD

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_REGION_PROG_ERR [chars], Failed to program [chars] region in FAD

Explanation    edge_l2fwd_table failed to program TCAM region in FAD. The region is specific to feature(L2TPv3/VPLS etc)

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_TCAM_FORMAT_PROG_ERR [chars], Failed to program [chars] TCAM format in FAD

Explanation    edge_l2fwd_table failed to program feature specific TCAM format in FAD layer.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FAD_UPDATE_ERR [chars], Failed to update lookup entry for [chars] in FAD

Explanation    edge_l2fwd_table failed to update l2fwd lookup entry in FAD

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-FM_CONFIG_ERR [chars], Failed to set [chars] feature config in FM

Explanation    edge_l2fwd_table failed to set feature specific config processing in FM.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-PLU_MALLOC_ERR [chars], Failed to allocate memory for the PLU Leaf

Explanation    edge_l2fwd_rewrite Forwarding memory module failed to allocate memory for the PLU leaf

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-PLU_WRITE_ERR [chars],[dec],PLU write error:[chars]

Explanation    edge_l2fwd_rewrite Failed while writing into the PLU though the Forwarding Memory Manager

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-reg_err [chars],[dec] Table registeration failed ! Table type:[chars], direction:[dec]

Explanation    edge_l2fwd_table failed to register the memory requirement and populate the memory handle

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-TABLE_MALLOC_ERR [chars], Failed to allocate memory for the Table: [chars]

Explanation    edge_l2fwd_rewrite Forwarding memory module failed to allocate memory for the Table

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-TLU_MALLOC_ERR [chars], Failed to allocate memory for the TLU Leaf

Explanation    edge_l2fwd_rewrite Forwarding memory module failed to allocate memory for the TLU leaf

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-2-TLU_WRITE_ERR [chars],[dec],TLU write error:[chars]

Explanation    edge_l2fwd_rewrite Failed while writing into the TLU though the forwarding memory manager

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-edge_l2fwd_table-3-ERR [chars], [dec] error, reason:[chars]

Explanation    edge_l2fwd_table generic error

Recommended Action    Pls get the information specified under the component required_info and call your Cisco technical support representative and provide the representative with the gathered information with this error message text

EGRESSQ_HW_DLL Messages

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-ENQ_PKT_LOGIC_ERROR Sharq ENQ packet logic error occurred, shq_enq_reg_debug_mux [hex]

Explanation    Egress Queue Manager encountered a ENQ packet logic error. Possible cause for this error condition is a faulty hardware.

Recommended Action    No action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-ERR_MEM_ALLOC Failed to allocate memory for [chars]

Explanation    System failed to allocate memory. It's likely that the system is running low on memory. Following are some reasons: 1) Failed to allocate memory for Egressq client add. 2) Failed to allocate memory for Egressq mapping table. 3) Failed to allocate memory for Queue leaky bucket limit table Memory. 4) Failed to allocate memory for Queue leaky bucket limit table memory. 5) Failed to allocate memory for Group leaky bucket limit table memory. 6) Failed to allocate memory for Group leaky bucket limit table memory. 7) Failed to allocate memory for Port leaky bucket limit table memory. 8) Failed to allocate memory for PLIM Asic back pressure table memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-FAIL_TO_GET_BP_MAP_FROM_PLIM_AISC Failed to get backpressure map from Plim ASIC [dec]. reason [chars]

Explanation    Sharq driver invoke Plim ASIC dll to retrieve the per port backpressure map but failed.

Recommended Action    Please check Plim ASIC and related driver process status, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-FCRAM_BIST_FAILURE FCRAM BIST failed, channel: [dec], count: [dec], error_addr: [hex]

Explanation    Egress Queue Manager encountered a FCRAM BIST failure error. Possible cause for this error condition is a faulty hardware.

Recommended Action    No action is required. Process will be automatically restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-FORWARD_PACKET_TO_UNALLOCATED_QUEUE Forward packets sent to unallocated egress queue [dec]. (queue state: [chars], queue length: [dec] bytes)

Explanation    Egressq driver detected that packets were sent to an Egressq queue which is unallocated. These packets will not be serviced and will remain in the queue until this queue is allocated and becomes active, or asic reset or linecard reload.

Recommended Action    If this message appears more than once in response to the specific action taken or if the message indicates a large number of bytes (more than 10MB) in an unallocated queue(s), Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-HW_ERROR [chars]

Explanation    Egress Queue Manager encountered a HW error. This is a severe error and ASIC will be reset by the driver.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-NON_ZERO_Q0_COUNTER EgressQ detected packets sent to Illegal queue (counter value [hex])

Explanation    Egressq driver detected that packets are sent to Q0, which is invalid queue.

Recommended Action    If this message appears more than once in short period, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-QUEUE_STUCK EgressQ Stuck condition detected (PLIM link [dec], link trained: [chars], Port [dec], Group [dec], Queue [dec], Queue state: [chars])

Explanation    Egressq driver detects the queue stuck condition (CSCsj48554). There is no packet output from one or more of the PLIM links and the queue length for related queue(s) is building up.

Recommended Action    By default, driver will perform the asic soft reset after detecting queue stuck condition. If this message appears more than once in short period, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-SBE_THRESHOLD_EXCEED Single Bit Error rate exceeded configured high threshold value: [chars]

Explanation    Egressq SBE rate has exceeded the configured high threshold value. This is a self healing error condition.

Recommended Action    No action is required. It is a self healing error. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-3-UNALLOCATED_QUEUE_NOT_EMPTY Packets present in unallocated egress queue [dec]. (queue state: [chars], queue length: [dec] bytes)

Explanation    Egressq driver detected that packets were present in an Egressq queue which is unallocated. These packets will not be serviced and will remain in the queue until this queue is allocated and becomes active. This situation should normally not happen, but may possibly happen during transient conditions when egress queue information is being updated (for e.g. on SPA OIR). During this brief time period, one or few packets may be sent to an incorrect queue.

Recommended Action    If this message appears more than once in response to the specific action taken or if the message indicates a large number of bytes (more than 10MB) in an unallocated queue(s), Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-7-ERR_EVM_FAIL EVM error : [chars] reason : [chars]

Explanation    An internal error was detected when trying to create EVM connection. It can fail during following scenarios: 1) EDM registration/connect/notify. 2) BAG's rule registration failed.

Recommended Action    No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-7-ERR_INTERNAL Internal error : [chars] reason : [chars]

Explanation    An internal error was detected. There are several scenarios which can cause this error condition. Error message describes the cause. Some of these error conditions are serious and result in driver process restart, e.g. ASIC Init/remap, enable/disable failure. Following are some of the reasons for this internal error: 1) Obsolete API usage, it can be caused due to uncompatible component installed in the system. 2) Interface creation failed due to egressq port creation failure. 3) Can't map Interface handle to egressq port, it could be because of: a) Invalid interface handle passed. b) Internal interface to port mapping table is corrupted. 4) Egressq ASIC reinitialization failed, this is an irrecoverable situation, and Egressq driver will be restarted. 5) Egressq Group/Queue creation/ deletion failed. 6) ASIC enable /disable failed.

Recommended Action    No action is required. The process will automatically retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ_HW_DLL-7-ERR_LWM_FAIL LWM message send failed: [chars] reason: [chars]

Explanation    An internal error was detected when trying to send a LWM message. There are several scenarios which can cause this error condition. Error message describes the exact cause.

Recommended Action    No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

EGRESSQ Messages

Error Message     
 
    
    
   

%L2-EGRESSQ-3-ERR_MEM_ALLOC Failed to allocate memory for [chars]

Explanation    System failed to allocate memory. It's likely that the system is running low on memory. Following are some reasons: 1) Failed to allocate memory for Egressq client add. 2) Failed to allocate memory for Egressq mapping table. 3) Failed to allocate memory for Queue leaky bucket limit table Memory. 4) Failed to allocate memory for Queue leaky bucket limit table memory. 5) Failed to allocate memory for Group leaky bucket limit table memory. 6) Failed to allocate memory for Group leaky bucket limit table memory. 7) Failed to allocate memory for Port leaky bucket limit table memory. 8) Failed to allocate memory for PLIM Asic back pressure table memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-EGRESSQ-7-ERR_CLIENT_REG Client registration failed: [chars] reason: [chars]

Explanation    An internal error was detected while clients are registering to Egressq process.

Recommended Action    No action is required. Clients will automatically retry to connect to Egressq. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ-7-ERR_EVM_FAIL EVM error : [chars] reason : [chars]

Explanation    An internal error was detected when trying to create EVM connection. It can fail during following scenarios: 1) EDM registration/connect/notify. 2) BAG's rule registration failed.

Recommended Action    No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ-7-ERR_INTERNAL Internal error : [chars] reason : [chars]

Explanation    An internal error was detected. There are several scenarios which can cause this error condition. Error message describes the cause. Some of these error conditions are serious and result in driver process restart, e.g. ASIC Init/remap, enable/disable failure. Following are some of the reasons for this internal error: 1) Obsolete API usage, it can be caused due to uncompatible component installed in the system. 2) Interface creation failed due to egressq port creation failure. 3) Can't map Interface handle to egressq port, it could be because of: a) Invalid interface handle passed. b) Internal interface to port mapping table is corrupted. 4) Egressq ASIC reinitialization failed, this is an irrecoverable situation, and Egressq driver will be restarted. 5) Egressq Group/Queue creation/ deletion failed. 6) ASIC enable /disable failed.

Recommended Action    No action is required. The process will automatically retry. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EGRESSQ-7-ERR_LWM_FAIL LWM message send failed: [chars] reason: [chars]

Explanation    An internal error was detected when trying to send a LWM message. There are several scenarios which can cause this error condition. Error message describes the exact cause.

Recommended Action    No action is required. The process retries automatically. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ELO_COMMON Messages

Error Message     
 
    
    
   

%L2-ELO_COMMON-3-SYSMGR_FAIL Unable to signal that process is exiting: [chars]

Explanation    The process has failed to inform System Manager that it is shutting down. The process will exit anyway, but it is possible that any configuration entered will not cause SysMgr to restart the process. In this case, a timeout will occur when committing configuration, and the config will fail to apply.

Recommended Action    If configuration fails to apply, recommitting it should correct the issue. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO_COMMON-4-EVM_CLEANUP_FAILED Failed to cleanup Event Manager: [chars]

Explanation    Whilst exiting, an error was encountered cleaning up the Event Manager. This process will exit anyway, and no further errors should be seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO_COMMON-4-PROC_READY_FAILED Unable to signal process ready: [chars]

Explanation    The process failed to inform System Manager that it is ready, and will be restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO_COMMON-4-VERIFY_CLEANUP_FAILED Failed to cleanup common verification module: [chars]

Explanation    Whilst exiting, an error was encountered cleaning up a common module. The process will exit anyway, and no further errors should be seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO_COMMON-4-VERIFY_INIT_FAILED Failed to initialize common verification module: [chars]

Explanation    The process has failed to initialize a module, and will be restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ELO Messages

Error Message     
 
    
    
   

%L2-ELO-3-BAD_CONFIG Invalid configuration values applied: [chars]

Explanation    Invalid configuration has been incorrectly applied. This can potentially indicate a recent change in acceptable configuration values, or an internal fault.

Recommended Action    Check that all configuration is within the acceptable ranges for the current version of the software and the installed hardware. If the error persists, and all values are within range, copy and save this message, and call your technical support representative for assistance.

Error Message     
 
    
    
   

%L2-ELO-3-COULD_NOT_GET_NODEID Ethernet Link OAM Daemon failed to determine the node it is running on: [chars]

Explanation    The Ethernet Link OAM Daemon failed to determine the ID of the node on which it is running. It will exit, and should be restarted by System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-COULD_NOT_REMOVE_CAPS Failed to remove PFI caps from interface 'CH[hex]': [chars]

Explanation    The Ethernet Link OAM Daemon failed to clean up a caps entry in PFI for the named interface. This error is not fatal in itself, although it may prevent OAM from being re-enabled on the given interface until the problem is resolved.

Recommended Action    Read the error message, and attempt to resolve any issue that may have caused it. Restarting the Ethernet Link OAM Daemon will then allow it to resynchronise with PFI and cleanup the dangling caps. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-DAEMON_INIT_FAILED Ethernet Link OAM Daemon failed to initialize [chars]: [chars]

Explanation    The Ethernet Link OAM Daemon failed to initialize correctly, and will now exit. It should be restarted by SysMgr.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-ERRDIS_FAILED CH[hex]: failed to Error-Disable the port: [chars]

Explanation    The port should have been Error Disabled, but an unexpected error has prevented it from being shut down. The port is still up, and will not be disabled.

Recommended Action    Shutdown the port manually if it is still desirable to bring it down. Otherwise, no action is required. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-EXITING Ethernet Link OAM Daemon failed to process events: [chars]

Explanation    The Ethernet Link OAM Daemon failed to process an event, and will now exit. It should be restarted by SysMgr, allowing it to resynchronise its internal state.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-LOOPBACK_SET_FAILED [chars]: Failed to change Loopback state in the platform: [chars]

Explanation    An attempt to change the Loopback state of an interface failed. This will either be in response to a local command to change the remote peer's Loopback state, or a command on the remote peer to put this interface in slave loopback mode.

Recommended Action    Retry the Loopback operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-PFI_CLEANUP_FAILED_NOMEM Failed to allocate sufficient memory to clean up OAM data from interfaces within PFI

Explanation    Insuffient memory is available to perform a clean up operation. PFI data structures have not been correctly cleaned up.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Once this is done, restart the Ethernet Link OAM daemon in order to force a resynchronisation, which will clean up the dangling data structures.

Error Message     
 
    
    
   

%L2-ELO-3-RECEIVE_OAMPDU_FAILED Failed to successfully receive an OAMPDU from SPIO: [chars]

Explanation    The Ethernet Link OAM Daemon was unable to receive an OAMPDU successfully from SPIO. This could be due to the OAMPDU not being received properly or being corrupt such that the OAMPDU can't be properly processed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-SPIO_INTF_INIT [chars]: Failed to register for packet IO on interface initialisation: [chars]

Explanation    The Ethernet Link OAM Daemon was unable to register the specified interface to send and receive packets. This is likely caused by a memory resource allocation error.

Recommended Action    Restarting the process will cause a retry of the initialisation, which should successfully register for packet IO. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-3-SPIO_MODULE_INIT Failed to register for packet IO on initialisation: [chars]

Explanation    The Ethernet Link OAM Daemon was unable to register the module to send and receive packets. This is likely caused by a memory resource allocation error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-CHKPT_SAVE_FAILED CH[hex]: failed to save checkpoint entry: [chars]

Explanation    The Ethernet Link OAM Daemon failed to save the checkpoint entry for the given interface. Although this error is not immediately fatal, information will be lost if the process restarts before successfully saving its checkpoint data.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-DAEMON_CLEANUP_FAILED Ethernet Link OAM Daemon failed to cleanup [chars]: [chars]

Explanation    The Ethernet Link OAM Daemon failed to cleanup correctly. It will exit anyway, and no further errors should be seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-INVALID_PLATFORM_EVENT_IFH Platform event triggered on interface 'CH[hex]' for which OAM is not configured

Explanation    The platform has triggered an event for an interface that has not been configured for Ethernet Link OAM. This indicates a bug in the software.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-INVALID_PLATFORM_EVENT_TYPE An unknown event of type '[hex]' has been triggered by the platform

Explanation    The platform has triggered an event that is not recognized. This is most likely due to a bug in the platform layers.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-LOOPBACK_FAILED Etherenet Link OAM Daemon has failed to initiate loopback mode with a remote peer

Explanation    The Ethernet Link OAM Damon has failed to initiate loopback mode. Loopback mode is unavailable until the issue is resolved.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-NOT_IN_LOOPBACK [chars]: Unable to exit Slave Loopback mode as requested, because we're not currently in loopback mode

Explanation    A requset has been made by the remote peer to stop Slave loopback mode. However, we are not currently in Slave loopback mode. This indicates that the remote peer is out of sync with our current state.

Recommended Action    Start slave Loopback mode before attempting to stop it.

Error Message     
 
    
    
   

%L2-ELO-4-PFI_ERROR CH[hex]: [chars] notification received from PFI, but interface does not have OAM configured

Explanation    Unexpected updates have been received by the Ethernet Link OAM Daemon regarding interfaces on which OAM is not configured. This indicates that a resync is required between the OAM process and PFI.

Recommended Action    Restart the Ethernet Link OAM Daemon on the affected node. This will force a resync of the state with PFI. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-4-SEND_FAILED [chars]: Failed to send a [chars] message: [chars]

Explanation    Failed to send a message out of the given interface. The message has been lost, and will not be delievered to the remote peer.

Recommended Action    Resynchonrisation mechanisms should ensure subsequent messages are correctly sent. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-6-CPU_STARVED Ethernet Link OAM Daemon has been unable to send heartbeats for [unsigned long long int] ms

Explanation    The Ethernet Link OAM Daemon has been blocked or starved of CPU time. As a result, it will not have been able to send out periodic heartbeats regularly, potentially causing OAM sessions to drop. The problem is likely due to unusually high load on the system.

Recommended Action    Identify any potential high CPU users, and reduce their impact. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_CAPABILITIES_CONFLICT [chars]: Configuration conflict

Explanation    Discovery mode cannot complete due to a conflict in the required configuration of the remote peer.

Recommended Action    Ensure that the configuration requirements on this interface match the configuration of the remote OAM peer.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_DISCOVERY_TIMEOUT [chars]: OAM discovery failed to complete in the specified time

Explanation    Discovery mode has been ongoing for the configured timeout, but no suitable response has been received from the remote peer.

Recommended Action    Ensure the remote OAM peer is correctly configured and that the link is up.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_REMOTE_CRITICAL_EVENT [chars]: Remote critical event detected

Explanation    The remote peer has indicated a critical event.

Recommended Action    No specific IOS-XR action needs to be performed.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_REMOTE_DYING_GASP [chars]: Remote dying gasp detected, with reason: [chars]

Explanation    The remote peer has indicated a dying gasp. This means that the remote peer is coming down.

Recommended Action    Restart the remote peer.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_REMOTE_LINK_FAULT [chars]: Remote link fault detected

Explanation    The remote peer has indicated that a link fault has occurred. This indicates a uni-directional link.

Recommended Action    Check the wiring between the two interfaces.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_REMOTE_LOOPBACK [chars]: OAM [chars] loopback has been [chars] on the interface

Explanation    The OAM session has either entered or exited local or remote loopback. If loopback has been entered then traffic flow will be disrupted until it is exited at which point normal functionality will resume.

Recommended Action    None. This is an informational message.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_SESSION_DOWN [chars]: OAM session has gone down

Explanation    The OAM session has ended. Either it has been deconfigured, or no response has been received from the OAM peer in the configured time interval.

Recommended Action    Check that the remote peer is correctly configured still. If it is, then a large number of packets may be being dropped on the link.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_SESSION_UP [chars]: OAM session has come up

Explanation    The OAM session has been fully established, and regular heartbeat messages are being sent and received.

Recommended Action    None. This is an informational message.

Error Message     
 
    
    
   

%L2-ELO-6-INTF_THRESHOLD_BREACHED [chars]: [chars] [chars] threshold breached

Explanation    A threshold has been breached in the hardware. This is an indication of a deteriorating link.

Recommended Action    No specific IOS-XR action needs to be performed.

Error Message     
 
    
    
   

%L2-ELO-6-LOOPBACK_CANCEL [chars]: Cancelling loopback mode as our MAC is lower than the remote MAC

Explanation    An attempt has been made to start loopback mode from both peers simultaneously. As per the IEEE 802.3 OAM specification, this OAM client has cancelled the request as the local MAC address is lower than the remote MAC address.

Recommended Action    Retry the Loopback operation from this peer once the remote loopback session on the remote peer has been terminated.

Error Message     
 
    
    
   

%L2-ELO-6-MISCONFIGURED_INTERFACE The profile configuration from profile '[chars]' cannot be applied as the platform does not support all the configured values: [chars]

Explanation    A profile can be configured that has configuration parameters that are not supported for all interfaces on the router. If that profile is later attached to an interface for which not all its values are supported, this message is generated. The interface will use the default values for any parameter that is out of range. The configuration parameters that may not be supported are support for remote loopback and support for link monitoring events. Further, the window size of a link monitor event must be a multiple of the interface's statistics' poll interval.

Recommended Action    Nothing need be done if the default values are acceptable for the invalid parameters. Otherwise, modify the profile to contain only configuration that is supported for the interfaces to which it is attached, or use an alternate profile for this interface.

Error Message     
 
    
    
   

%L2-ELO-6-MISWIRED [chars]: Mis-wiring detected

Explanation    The Mis-Wiring Detection feature of Ethernet Link OAM has detected a mis-wiring situation. Mis-wiring occurs when the TX wire of an interface is not connected to the same remote interface as the RX wire.

Recommended Action    Check the wiring of the specified interface. By setting the mis-wiring action to 'log', and using the packet debugging facility of Ethernet Link OAM ('debug ethernet oam packets'), the MAC addresses of the source of packets can be used to identify where the links are.

Error Message     
 
    
    
   

%L2-ELO-6-NO_PROFILE Profile '[chars]' is not configured, but has been attached to an interface

Explanation    A profile has been attached to an interface. However, that profile has not yet been configured. Until the named profile is created, the interface will use the default profile configuration.

Recommended Action    Create the specified profile, or remove the configuration associating the profile with the interface.

Error Message     
 
    
    
   

%L2-ELO-6-REMOTE_MASTER_LEFT_LOOPBACK [chars]: Local client in Slave Loopback, and remote Master has abruptly left Loopback mode. Exiting Slave loopback locally

Explanation    While running the link in OAM Loopback mode, with the local peer as the Slave, the Master peer abruptly ended Loopback mode without first informing this peer to end it. This may indicate a problem with the remote peer.

Recommended Action    No corrective action is required. This peer has exited Loopback mode also, and the link is now back to normal operational status.

Error Message     
 
    
    
   

%L2-ELO-6-REMOTE_SLAVE_LEFT_LOOPBACK [chars]: Remote client has abruptly left Slave loopback mode. Exiting loopback state

Explanation    While running the link in OAM Loopback mode, with the local peer as the Master, the Slave peer abruptly ended Loopback mode without being told to do so by this peer. This may indicate a problem with the remote peer.

Recommended Action    No corrective action is required. This peer has exited Loopback mode also, and the link is now back to normal operational status.

Error Message     
 
    
    
   

%L2-ELO-6-UNEXPECTED_LOOPBACK_STATE [chars]: An unexpected multiplexer and parser state have been received from the remote peer.

Explanation    While running the link in OAM Loopback mode the local peer received an unexpected multiplexer and parser state combination from the remote peer. This may indicate a problem with the remote peer.

Recommended Action    No corrective action is required. This peer has exited Loopback mode also, and the link is now back to normal operational status.

Error Message     
 
    
    
   

%L2-ELO-6-UNEXPECTED_STATE A variable response from the remote peer contained invalid state.

Explanation    Whilst parsing a variable response packet an invalid state was found. This could be an indication of a faulty implementation on remote peer.

Recommended Action    No specific IOS-XR action needs to be performed.

ELOGM Messages

Error Message     
 
    
    
   

%L2-ELOGM-4-DEBUG_CLEANUP_FAILED Ethernet Link OAM Global Manager failed to cleanup debug: [chars]

Explanation    Whilst exiting, the Global Manager failed to cleanup the debug module. The process will exit anyway, and no further errors should be seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELOGM-4-DEBUG_INIT_FAILED Ethernet Link OAM Global Manager failed to initialize debug: [chars]

Explanation    During initialization, the Global Manager failed to initialize the debug module and will now exit. It should be restarted by System Manager and resynchronize it's internal state.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELOGM-4-EXITING Ethernet Link OAM Global Manager failed to process events: [chars]

Explanation    The process failed to process incoming events, and will exit. It should be restarted by System Manager and resynchronize its internal state.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ELOGM-4-INIT_FAILED Ethernet Link OAM Global Manager failed to initialize: [chars]

Explanation    During initialization, an unexpected error was encountered. The process will exit and be restarted by System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

EMA Messages

Error Message     
 
    
    
   

%L2-EMA-4-ERR_ACTIVATE Failure during activation of [chars]. Error: [chars]

Explanation    A failure occurred during the activation of the process. Activation occurs when the card transitions to ACTIVE state. This error resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EMA-4-ERR_EVM_EVENT_BLOCK Unrecoverable error in event loop. Error: [chars]

Explanation    An error (other than EINTR) occured in the event loop. The process has exited and restarted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EMA-4-ERR_INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EMA-4-ERR_SYSMGR Failure communicating readiness to System Manager. Error: [chars]

Explanation    The process was initialized successfully but was unable to inform System Manager of the success.

Recommended Action    Check on the status of the sysmgr process on the node from which the error was reported. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

EPI Messages

Error Message     
 
    
    
   

%L2-EPI-3-ATTR_NOTIFY_FAILED Failed to notify a client of a change to interface attributes - out of memory

Explanation    The EPI library was unable to notify a client of a change to some interface attributes because it was unable to allocate memory. This may result in the client of the EPI library attempting to send invalid packets.

Recommended Action    This message will be seen as a result of a configuration change if the system is low on memory. Attempt to free up some memory and reapply the configuration change that caused this message to be displayed. If the problem persists, try restarting the process using this library. If this does not help, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EPI-3-INIT_FAILED Failed to initialize, [chars] failed [unsigned int]: [chars]

Explanation    An error was encountered while the EPI library was initializing. The error message contains details about the source of the error.

Recommended Action    The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EPI-3-PAK_FREE_FAILED Failed to free packet buffer: [chars]

Explanation    An error was encountered while the EPI library was attempting to free a packet buffer. The error message contains details about the source of the error.

Recommended Action    This message should be harmless, but it is possible that there is an inconsistency that may lead to a memory leak. If the problem persists, try restarting the process. If this does not help, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-EPI-3-PKT_OVERFLOW The maximum number of packets being stored for interface: CH[hex] has been exceeded

Explanation    The EPI library has been asked to create a packet for an interface which already has the maximum number of supported packets in storage. EPI has created the packet, but may have difficulty updating packets on this interface in future.

Recommended Action    This message is likely to indicate an internal error in the process that means it is not freeing its old packet information correctly. If the process is not restarted then a future configuration change for the interface in question may not be reflected in the generated packets. Try restarting the process and, if the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ESPI Messages

Error Message     
 
    
    
   

%L2-ESPI-3-ERR_MEM_ALLOC Memory allocation failed for internal data structures

Explanation    Memory was not available for an internal data structure. The requested operation could not be accomplished because of a low memory condition. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Run the debug show commands, gather data and contact tac. Also ensure the LC is populated with the minimum amount of memory required for proper operation. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ESPI-3-RX_ERR [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware/software problem on the FPGA. This affects communication bus between adjacent ASICs on the hardware datapath. The LC may not be able to forward data packets and traffic loss may be observed due to this error. The From CPP or To CPP direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    ESPI Interface is Reset and Recovered

Error Message     
 
    
    
   

%L2-ESPI-3-TX_ERR [chars]: [chars] [hex]

Explanation    This error usually indicates an internal hardware/software problem on the FPGA. The affects the communication bus between adjacent ASICs on the hardware datapath. The LC may not be able to forward data packets and traffic loss may be observed due to this error. The From CPP or To CPP direction, the detailed error string and the slot number are provided as part of the message.

Recommended Action    ESPI Interface is Reset and Recovered

eth_gl Messages

Error Message     
 
    
    
   

%L2-eth_gl-4-EVENT_BLOCK An error was received while waiting for an event: (error: [chars])

Explanation    The indicated process encountered an error while listening for events. The process will automatically restart and retry.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-eth_gl-4-INIT_FAILED Initialization failed: [chars] (error: [chars])

Explanation    The indicated process failed to initialize. Previous messages may give the reason. The process will automatically restart and retry. Until it succeeds, Ethernet functionality may be impacted.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ETH_OUTPUT Messages

Error Message     
 
    
    
   

%L2-ETH_OUTPUT-3-ERR_NO_MEM Out of memory (failed attempt to reserve [unsigned int] bytes)

Explanation    The Ethernet Output process was not able to allocate the memory that it needed to complete the operation. Ethernet Output process client functionality on the affected node may be reduced until the problem is resolved.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

ETHER_NETIO Messages

Error Message     
 
    
    
   

%L2-ETHER_NETIO-4-DEBUG_REG Debug registration failed: [chars]

Explanation    It was not possible for the Ethernet slow path support to initialize its debugging support. Some of the output from debug ether-netio output may be incomplete.

Recommended Action    No action is required.

ether_spa_intr Messages

Error Message     
 
    
    
   

%L2-ether_spa_intr-1-MAX_BURST_EVENT A Maximum burst of [chars] has occurred for [dec]/[dec]/[dec] [chars]

Explanation    A maximum burst of interrupts have occurred on the interface/ SPA. The interrupt in question has been permanently disabled. Manual intervention required to re-enable the interrupt.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ether_spa_intr-6-BURST_EVENT Burst of [chars] occurred for [dec]/[dec]/[dec]. No Manual intervention required

Explanation    A burst of interrupts have occurred and the interrupt manager has throttled the interrupt. It will be re-enabled automatically after the pause timer expires and no further intervention is required.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ether_spa_mac_error Messages

Error Message     
 
    
    
   

%L2-ether_spa_mac_error-1-RECOVERY_FAILED A Maximum MAC Error recovery retries has occurred for [dec]/[dec]/[dec]. PORT DISABLED after exceeding maximum retries. LINK force DOWN. Manual intervention required to bring port back into operation. Issue shutdown and no-shutdown on the interface to bring port into operation.

Explanation    A MAC Frame Corruption occurred on the interface, concern port is in error condition after maximum recovery retries. The concern port has been permanently disabled. Manual intervention required to re-enable the port.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

ether_spa_plugin Messages

Error Message     
 
    
    
   

%L2-ether_spa_plugin-6-ERRORRECOVER A Hardware or Software error occurred. Reason : [chars] Automatic Error recovery initiated. No further intervention required.

Explanation    An error occurred in one of the devices, recovery would be attempted. If recovery succeeds no further messages would be logged and no intervention would be required.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ether_spa_plugin-6-LINK_EVENT Interface TenGige [dec]/[dec]/[dec], [chars]

Explanation    This will log the reason for the link to go down

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ether_spa_plugin-6-OPTICS_OIR An Optics is [chars] for bay [dec] and port [dec]

Explanation    The Optic Interface Module (OIM) for the specified port either has been inserted or removed.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-ether_spa_plugin-6-UNSUPPORTED_OPTICS [chars] port [dec] security check failed . Disable

Explanation    An Unsupported Optic Interface Module (OIM) for the specified port has been inserted .

Recommended Action    No action is required.

ETHER Messages

Error Message     
 
    
    
   

%L2-ETHER-1-CONFIGERROR Ethernet: Invalid configuration, [chars] is not supported by this interface

Explanation    Invalid configuration

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-1-IMERROR Ethernet: [chars]() line [dec]: interface manager call [chars] failed: [chars]

Explanation    The call to im failed for some reason.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-2-DEVCTLFAILED Ethernet: [chars]: devctl failed with code [hex]

Explanation    A devctl call failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-2-OUTOFMEMORY Ethernet: [chars]() line [dec]: out of memory, unable to create [chars]

Explanation    Card has no more memory available.

Recommended Action    Verify that the card is not out of memory. Contact your Cisco technical support representative if the problem persists.

Error Message     
 
    
    
   

%L2-ETHER-2-SYSDBREGISTERFAILED Ethernet: Sysdb registration failed ([chars])

Explanation    The driver failed to initialize communication with sysdb.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-BADASYNCEVENT Ethernet: Unknown asynchronous event [dec] in [chars]

Explanation    An invalid asynchronous event was received by the driver.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-BDL_IIR_OP_FAILED The basecaps failed to process a bundle IIR [chars] message on [chars], error: [chars]

Explanation    The ethernet driver failed to process a bundle IIR notification message. Further it is not able to propagate the message back to the virtual interface owner, and hence it is possible that the Ether basecaps is out of step with the bundle configuration.

Recommended Action    Restart the ether_caps_partner process in an attempt to recover, or if this fails, detach and re-attach the physical member interface that the error was reported on by unconfiguring and reconfiguring the bundle member id.

Error Message     
 
    
    
   

%L2-ETHER-3-DILBFAILED Ethernet: [chars]() line [dec]: failed to [chars].

Explanation    A dilb call failed, preventing communication between threads/processes.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-DPCFAILED Ethernet: [chars]() line [dec]: DPC call to [chars] failed.

Explanation    A direct procedure call failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-EDMERROR Ethernet: [chars]() line [dec]: Bad sysdb call for tuple [chars]: [chars]

Explanation    An edm sysdb call was improperly formed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-INITFAILED Ethernet: [chars]() line [dec]: init failed in function [chars]: [chars]

Explanation    Basic initialization failed due to problem in a called function.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-INVALIDARGSIZE Ethernet: Incompatible structure definition for [chars] in [chars]

Explanation    A structure passed is the wrong size due most likely to compilation problem.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-INVALIDTIMER Ethernet: [chars](): Invalid timer type [dec]

Explanation    An invalid timer type was found in an expired timer.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-RESTARTFAILED Ethernet: [chars]() line [dec]: [chars]: [dec]

Explanation    Restarting the driver failed for some reason.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If the problem persists, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-3-TIMERINITFAILED Ethernet: Failure initializing asynchronous timers: [chars]() - [chars]

Explanation    A failure occured while creating or initializing the timers for the driver.

Recommended Action    Make sure there is enough memory available. Contact your representative if the problem persists.

Error Message     
 
    
    
   

%L2-ETHER-3-UNSUPPORTEDSTATS Ethernet: Unsupported stats request [dec] in [chars]

Explanation    A driver has requested an unsupported stats type.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-4-ERR_EVM_EVENT_BLOCK Failure during receipt of message. Error: [chars]

Explanation    A failure occurred handling a message arriving at one of the Ethernet capsulation processes. Under normal circumstances the process restarts with no impact to functionality. If this error message is seen repeatedly then Ethernet services may be affected on all Ether type interfaces on the given node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-ETHER-4-INIT Failure during intialisation of [chars] in a Ether basecaps process. Error: [chars]

Explanation    A failure occurred during the initialisation of one of the Ethernet capsulation processes. Under normal circumstances the process restarts with no impact to functionality. If this error message is seen repeatedly then Ethernet services may be affected on all Ether type interfaces on the given node.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FB_PLIM Messages

Error Message     
 
    
    
   

%L2-FB_PLIM-3-ERROR [chars]: [hex], [chars]

Explanation    An error occurred in 1p OC12-ch-ds1 PLIM process. This may cause features to not work properly.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_PLIM-3-ERROR_NO_RC [chars]

Explanation    An error occurred in 1p OC12-ch-ds1 PLIM process, which might involve exiting the process. Some features may not work if this error is seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_PLIM-3-INIT_ERROR [chars]: [hex], [chars]

Explanation    An error occurred initialization of 1p OC12-ch-ds1 PLIM process, which will involve exiting the process and recover.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_PLIM-3-ML_ERROR [chars]

Explanation    An error occurred in the 1p OC12-ch-ds1 Multilink platform dependent component. This may cause the multilink feature to not function properly.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_PLIM-3-ML_PULSE_ERROR [chars]

Explanation    An error occurred in the 1p OC12-ch-ds1 PLIM multilink pulse message processing. This may cause the multilink feature to not function properly.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_PLIM-4-WARNING [chars]: [hex], [chars]

Explanation    This is a warning message in the 1p OC12-ch-ds1 PLIM process to indicate anomolies which are not fatal. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FB_SHIM_ENCAP Messages

Error Message     
 
    
    
   

%L2-FB_SHIM_ENCAP-3-EINVAL [chars]: [hex], [dec]

Explanation    An invalid input condition detected.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_SHIM_ENCAP-3-NO_SHIM [chars]: [hex]

Explanation    The SHIM information not found for the interface given.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FB_SHIM_ENCAP-3-UNEXPECTED [chars]: [dec]

Explanation    Unexpected encap type

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FIB_IPV4 Messages

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ADJ_ERROR [chars] ifh: [hex], [chars]

Explanation    Platform IPv4 FIB, adjacency error

Recommended Action    Please collect the console log and following traces: show cef trace loc show cef platform trace [common|ipv4] all loc show adjacency hardware trace loc show bundle trace all loc show im trace loc Most of the time, these are harmless transient messages, caused by the delay in FIB and AIB processes learning about new interface. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ADJ_ERROR [chars] ifh: [hex], [chars]

Explanation    Platform IPv4 FIB, adjacency error

Recommended Action    Please collect the console log and following traces: show cef trace loc show cef platform trace [common|ipv4] all loc show adjacency hardware trace loc show bundle trace all loc show im trace loc Most of the time, these are harmless transient messages, caused by the delay in FIB and AIB processes learning about new interface. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ADJ_ERROR [chars] ifh: [hex], [chars]

Explanation    A runtime failure occurred in FIB engine layer while processing/updating adjacency information. The message string indicates the reason for the This message also provides a string interpretation of the error code and the interface handle.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv4 all location show im trace location show bundle trace location show adjacency hardware trace location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_INFO [chars] [dec]

Explanation    Platform IPv4 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_INFO [chars] [dec]

Explanation    Platform IPv4 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_INFO [chars] [unsigned int]

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv4 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    Platform IPv4 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    Platform IPv4 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv4 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERROR [chars]

Explanation    Platform IPv4 FIB, error

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERROR [chars]

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card whee the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv4 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-ERROR [chars]

Explanation    Platform IPv4 FIB, error

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv4] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV4-3-GEN_ERR FIB IPV4 internal error: [chars]

Explanation    An internal software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FIB_IPV4-5-RECURSIVE_LOOP FIB IPv4 Recursive loop: [chars]

Explanation    Recursive loop was detected. The route update will be dropped

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FIB_IPV4-6-INFO [chars]

Explanation    PLATFORM IPv4 FIB, Information

Recommended Action    The message is just for information. No action is needed.

FIB_IPV6 Messages

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ADJ_ERROR [chars] ifh: [hex], [chars]

Explanation    Platform IPv6 FIB, adjacency error

Recommended Action    Please collect the console log and following traces: show cef trace loc show cef platform trace [common|ipv6] all loc show adjacency hardware trace loc show bundle trace all loc show im trace loc Most of the time, these are harmless transient messages, caused by the delay in FIB and AIB processes learning about new interface. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_INFO [chars] [unsigned int]

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv6 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_INFO [chars] [dec]

Explanation    Platform IPv6 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv6] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_INFO [chars] [dec]

Explanation    Platform IPv6 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv6] all loc ). Also notice if the error message is transient or persistent. If errros persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_INFO_VERBOSE [chars] [chars] [chars] [dec]

Explanation    Platform IPv6 FIB, error information

Recommended Action    *SUPPORT*

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_INFO_VERBOSE [chars] [chars] [chars] [dec]

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. It provides more verbose information. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv6 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    Platform IPv6 FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv6] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. This message also provides an error code and a string interpretation of the error code. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv6 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERROR [chars]

Explanation    Platform IPv6 FIB, error

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv6] all loc ). Also notice if the error message is transient or persistent. If errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERROR [chars]

Explanation    A runtime failure occurred in FIB engine layer. Typically, this is an internal error. The message string indicates the reason for the failure. Here is a list of possible reasons for this message (not all-inclusive). - Failed to retrieve information from FIB objects. This condition indicates a problem with the software on the card where the error is seen. - Failed to initialize objects. This condition indicates a problem with the software on the card. Typically, this occurs when the software tries to initialize invalid objects. - Unexpected events. This condition indicates a problem where an event is triggered in the software unexpectedly on the card. - Invalid objects. This condition indicates a problem where the object being processed by the software is invalid.

Recommended Action    Please collect the console log and the CLI output. CLI RP show cef /RP LC show cef location show cef trace location show cef platform trace common all location show cef platform trace ipv6 all location /LC TECH show tech cef show version show install summary /TECH /CLI Also notice if the error message is transient or persistent. Report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-ERROR [chars]

Explanation    Platform IPv6 FIB, error

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|ipv6] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_IPV6-3-GEN_ERR FIB IPV6 internal error: [chars]

Explanation    An internal software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FIB_IPV6-5-RECURSIVE_LOOP FIB IPv6 Recursive loop: [chars]

Explanation    Recursive loop was detected. The route update will be dropped

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FIB_IPV6-6-INFO [chars]

Explanation    PLATFORM IPv6 FIB, Information

Recommended Action    The message is just for information. No action is needed.

FIB_MPLS Messages

Error Message     
 
    
    
   

%L2-FIB_MPLS-3-ERR_INFO [chars] [dec]

Explanation    Platform MPLS FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|mpls] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_MPLS-3-ERR_STR [chars], [chars] ([unsigned int])

Explanation    Platform MPLS FIB, error information

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|mpls] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

Error Message     
 
    
    
   

%L2-FIB_MPLS-3-ERROR [chars]

Explanation    Platform MPLS FIB, error

Recommended Action    Please collect the console log, FIB traces (show cef trace loc ), FIB platform trace (show cef platform trace [common|mpls] all loc ). Also notice if the error message is transient or persistent. If the errors persist, report to your technical support representative.

FR_EDM Messages

Error Message     
 
    
    
   

%L2-FR_EDM-2-INIT [chars] : [chars]

Explanation    Init error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_EDM-3-NO_STATS unable to get stats for vc [hex], [dec]

Explanation    The statistics manager returned null data for vc

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_EDM-3-NOMEM unable to allocate [dec] bytes of memory

Explanation    The system is low on memory and not enough was available to complete the request

Recommended Action    Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_INARP Messages

Error Message     
 
    
    
   

%L2-FR_INARP-2-CONNECT_IM failure on IM connection: [chars]

Explanation    This error indicates a problem with InARP/IM interaction.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-2-INIT failed to initialize: [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-IF_VC_CLASS unable to apply class [chars] to interface [chars]: [chars]

Explanation    A vc-class was configured on an interface but couldn't be applied for the given reason

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-INVALID_FD received an event on unknown fd [dec]

Explanation    An event was received with an unknown fd

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-NOMEM unable to allocate [dec] bytes of memory

Explanation    The system is low on memory and not enough was available to complete the request

Recommended Action    Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-PVC_VC_CLASS unable to apply class [chars] to interface [chars].[dec]: [chars]

Explanation    A vc-class was configured on an interface but couldn't be applied

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-SOCKET_SEND could not send on socket: [chars]

Explanation    Socket returned an error, not EAGAIN or EINTR

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-UNKNOWN_EVENT received an unknown event [hex]

Explanation    An unknown event was received

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-3-UNKNOWN_IDB received information about an unrecognised interface

Explanation    A set of IDBs are kept with information on each InARP interface. Somehow this information has become inconsistent with the system.

Recommended Action    Restart the main process (containing the InARP DLL) If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-4-UNKNOWN_INTFTYPE received an event for an unknown interface type: [dec]

Explanation    The system sent a messages which wasn't expected. It will be ignored.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_INARP-4-UNKNOWN_MSG received an unknown message: [dec]

Explanation    An unknown InARP message was received - it will be ignored

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_LMI Messages

Error Message     
 
    
    
   

%L2-FR_LMI-2-INIT LMI failed to initialize: [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-CODEP_ERROR Configured values of [chars] and [chars] conflict during application. Changing [chars] to [dec] to maintain consistency

Explanation    LMI parameters N392 and N393 are co-dependent - they must obey the rule N392 equals N393. Somehow SysDB is attempting to apply config which conflicts unreconcilably. The parameter being configured is adjusted to be equal to the other.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-ENCAP Unable to process Frame Relay encapsulation request

Explanation    An error occurred processing a request to set Frame Relay encapsulation on an interface. LMI will not be able to control the interface.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-FSM_T391_EXPIRY FSM in STOPPED state while timer is running: Interface [chars]

Explanation    This indicates that FSM has gone into an error condition. We should not have a valid timer expiry event if the FSM for this particular interface was in STOPPED state.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-IDB_INIT IDB initialization failure for [chars] - [chars]

Explanation    Interface creation within fr_lmi process failed for the named interface.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-IDB_SEARCH The interface specified by a handle is not one that LMI recognizes as running Frame Relay

Explanation    A call to rt_search failed to return an idb object.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-IM_ERR [chars]

Explanation    Error in IM operation. Ex: Connection to IM not getting established, or some IM API errored out.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-INVALID_VC An error occured while inserting the vc_idb into the tree, a invalid vc_idb(ifh [hex], dlci [dec]) exists

Explanation    Dangling VC found. Possible reasons: VC deletion failed in previous attempt or LMI did not get a deletion nfn from IM

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-KEEPALIVES An error occurred informing the VC Manager that LMI is [chars] responsible for the line state of an interface: [chars]

Explanation    An error occurred in the VCM call to set the keepalive state.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-LINE_STATE An error occurred informing the VC Manager of the line state: [chars]

Explanation    The VC Manager returned an error after receving a request to set the line state.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-MALLOC Memory allocation failed: [chars]

Explanation    A call to malloc failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-RECVFROM An error occurred receiving a packet: [chars]

Explanation    The socket call recvfrom returned an error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-SENDTO An error occurred sending a packet: [chars]

Explanation    The socket call sendto returned an error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-SET_DLCI_STATUS An error occurred sending the updated VC states to the VC Manager: [chars]

Explanation    The VC Manager returned an error after receving a request to update VC states.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-VC_CREATE Unable to create LMI DLCI [dec]: [chars]

Explanation    LMI was unable to create a VC it needed to function properly.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-3-VCM_VC_STATES LMI was unable to send all VC states to the VC Manager

Explanation    An error occurred sending the VC states to the VC Manager. This could have occurred searching LMI's internal database or in the call to the VCM.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_LMI-6-CODEP_CHANGE Changing defaulted value of [chars] to [dec] due to configured value of [chars]

Explanation    LMI parameters N392 and N393 are co-dependent - they must obey the rule N392 equals N393. Sometimes when one is changed the other must be changed as well to keep the protocol functioning properly.

Recommended Action    None. This is not an error, just a notification.

FR_NETIO Messages

Error Message     
 
    
    
   

%L2-FR_NETIO-3-MEMORY Failed to allocate [unsigned int] bytes

Explanation    The DLL has failed to acquire the required amount of memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-FR_NETIO-6-DEBUG_REG Debug registration failed: [chars]

Explanation    Debug message registration failed

Recommended Action    No action is required.

FR_SFRAR Messages

Error Message     
 
    
    
   

%L2-FR_SFRAR-2-INIT SFRAR failed to initialize: [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SFRAR-3-SYSMGR SFRAR process ready call failed: [chars]

Explanation    The call to inform the System Manager that SFRAR is running failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_SOCKET Messages

Error Message     
 
    
    
   

%L2-FR_SOCKET-2-INIT Socket failed to initialize: [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-CONN Failed to setup fr socket EVM connection: [chars]

Explanation    The fr_socket process failed to connect to the event manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-DPC_FAIL Failed to register [chars] protocol in netio

Explanation    The fr_socket process failed to send dpc message to Netio

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-NETIO_OUTPUT_FAIL Failed to send packet out to Netio: [chars]

Explanation    The fr_socket process failed to send packet out to Netio.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-NOMEM unable to allocate [dec] bytes of memory

Explanation    The system is low on memory and not enough was available to complete the request

Recommended Action    Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-PACKET_CONN Failure in packet manager connection: [chars]

Explanation    The fr_socket process failed to connect to packet manager

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-RESMGR_ATTACH Failed to setup fr socket as a resource manager: [chars]

Explanation    The fr_socket process failed to advertise itself to the system as a resource manager.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-SEND_ASYNC Failed to send async pulse [dec]: [chars]

Explanation    The fr_socket process failed to send async pulse to FR socket EVM

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_SOCKET-3-SYSMGR SysMgr process ready call failed: [chars]

Explanation    The call to inform the System Manager that the FR socket is running failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_UV Messages

Error Message     
 
    
    
   

%L2-FR_UV-3-ERR_ABORT_ENCAP_FAIL [dec] encap aborts failed: The system may now be in an inconsistant state.

Explanation    The FR Uberverifier has detected a misconfiguration. It was not able to cleanup its internal DB while handling encap abort creates.

Recommended Action    The misconfiguration can be corrected by restarting fr_uv process on the specific location on which this error message is seen. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_UV-3-ERR_MISCONFIG Misconfiguration: Item [chars] on interface [chars] is incompatible with other configuration. The system may now be in an inconsistant state.

Explanation    The FR Uberverifier has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier cannot correct this.

Recommended Action    The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_UV-3-EVENT Unrecoverable error in event loop. Error: [chars]

Explanation    An error (other than EINTR) occured in the event loop. The process must exit.

Recommended Action    Identify the location of the card where there error was reported. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory location location summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory location location summary output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_UV-3-INIT Failure during intialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_UV-3-SYSMGR Failure communicating readiness to System Manager. Error: [chars]

Explanation    The process was initialized successfully but was unable to inform System Manager of the success.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_VCM_EA Messages

Error Message     
 
    
    
   

%L2-FR_VCM_EA-2-INIT FR VCM EA failed to initialize: [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-2-INTERNAL_ERR [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-3-AIB_INIT_FAILED Failed during AIB initialization, err: [chars]

Explanation    The FR VCM EA process initialization failed whilst trying to connect to AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-3-BATCH_INTERFACE_ERROR Error during messaging: [chars]

Explanation    The FR VCM EA process has detected an error during messaging. Possible memory corruption or out of resource.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-3-DATABASE_KEY_MISSING Internal database access error

Explanation    The FR VCM EA process code/data is inconsistent. Possible coding error or data corruption.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-3-DLCI_MATCH_FAILED Failed DLCI match, err: [chars]

Explanation    The FR VCM EA has a wrong value of the DLCI and is not the same as what the MA sends.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM_EA-3-NO_STATS Failed to initialize FR VCM subinterface stats collection, err: [chars]

Explanation    The FR VCM EA subinterface stats collection initialization failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FR_VCM Messages

Error Message     
 
    
    
   

%L2-FR_VCM-2-CONFIG_INIT Configuration registration failed: [chars]

Explanation    Unable to register for configuration changes.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-2-CONNS Connection initialization failed: [chars]

Explanation    Unable to initialize connections to one or more servers.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-CONNECT_TO_L2VPN Connect to L2VPN server failed: [chars]

Explanation    FR VCM process on linecard tried to connect to L2VPN server on RP. Connect registration failed. FR L2 sub-interfaces will not be operational on this linecard.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-ENCAPS_TYPE Unable to specify [chars] encaps type for interface [chars]: [chars]

Explanation    The configuration in the NetIO DLL could not be updated, the system may continue with the existing encapsulation type

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-IDB FR [chars] IDB [chars] failed: [chars]

Explanation    Unexpected error on Interface Descriptor Block

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-IM_OP FR [chars] on [chars] failed: [chars]

Explanation    The operation on the named item is not completing successfully when it is expected to, and hence the FR support may be disabled

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-INTF_NOTFOUND FR interface [chars] not found

Explanation    An action has been performed on a FR interface, but FR doesn't have any information about the interface.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-MAIN_IF FR error on main interface [chars]: [chars]

Explanation    Unexpected error on the main interface

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-NOMEM unable to allocate [dec] bytes of memory

Explanation    The system is low on memory and not enough was available to complete the request

Recommended Action    Check the box for processes with excessive memory If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-PTP_VC FR PVC create (dlci [dec]) on PTP subinterface failed - only one PVC is allowed

Explanation    Point-to-point (PTP) subinterfaces only allow one PVC and an attempt to create a second PVC is being rejected

Recommended Action    Remove the old PVC before creating the replacement, or use a multipoint subinterface instead

Error Message     
 
    
    
   

%L2-FR_VCM-3-SUB_IF FR error on sub-interface [chars]: [chars]

Explanation    Unexpected error on the sub-interface

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-SYSDB_OP FR SysDB [chars] on [chars] failed: [chars]

Explanation    Unexpected failure performing a SysDB operation.

Recommended Action    Check SysDB is still running, and if not restart it. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-3-VC_EXISTS FR VC with DLCI [dec] already exists

Explanation    The DLCI is unique per 'main' interface and this dlci is already used

Recommended Action    None.

Error Message     
 
    
    
   

%L2-FR_VCM-3-VC_NOTFOUND FR VC with DLCI [dec] not found

Explanation    An operation was performed which expected a VC with the specified DLCI to exist, but it doesn't

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FR_VCM-6-DEBUG_REG Debug registration failed: [chars]

Explanation    Debug message registration failed

Recommended Action    No action is required.

FRMIB Messages

Error Message     
 
    
    
   

%L2-FRMIB-3-SYSDB FR MIB: [chars]: [chars]: [chars]

Explanation    This message indicates the FR MIB library fails to perform a SYSDB operation. *DDTS*

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

FSYNC Messages

Error Message     
 
    
    
   

%L2-FSYNC-3-COMMS_ERROR Communications error for node [chars]: [chars]%s

Explanation    A error occurred in the communication between Frequency Synchronization processes. Frequency Synchronization information may be out of sync.

Recommended Action    Restarting fsyncmgr on the card on which this message was seen may fix the problem. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-3-ESMC_SEND_TIMER Failed to re-arm the ESMC SSM send timer: [chars]

Explanation    An error occurred when attempting to re-arm the ESMC SSM send timer. No further SSMs will be sent from interfaces on the card on which this message was seen.

Recommended Action    Restarting fsyncmgr on the card on which this message was seen may fix the problem. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-COMMS_RETRY_FAILED Communications retry failed: [chars]%s

Explanation    A Frequency Synchronization process has failed to send a message and attempts to retry the send have also failed.

Recommended Action    The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-ESMC_RECEIVE_TIMER Failed to re-arm the ESMC SSM receive timer for [chars]: [chars]

Explanation    An error occurred when attempting to re-arm the ESMC SSM receive timer for the specified interface. Any SSMs received on the interface will continue to be handled, but any future peer timeouts (i.e. loss of SSMs) on the interface will go undetected.

Recommended Action    Restarting fsyncmgr on the card on which this message was seen may fix the problem. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-INIT_FAILED Failed to initialize: [chars]%s

Explanation    An error was encountered while the specified process was initializing. The error message contains details about the source of the error.

Recommended Action    The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-INPUT_PROGRAMMING_FAILED Failed to program the inputs for selection point [chars]: [chars]

Explanation    The Frequency Synchronization manager that generated the message failed to program the inputs for the specified selection point into the platform. Any changes to the inputs (for example, if an input is no longer available or if it's QL has changed) will not take effect.

Recommended Action    If the error message indicates an out-of-resource condition, then resolve the underlying resource issue, and restart the Frequency Synchronization manager on the affected node using the following command: process restart fsyncmgr location node Otherwise, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-INTF_IM_ERROR Interface manager failed to [chars] for [chars]: [chars]

Explanation    *SUPPORT*

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-INTF_STATUS_ERROR Failed to handle interface status change for [chars]: [chars]

Explanation    *SUPPORT*

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-LOST_EVENT [chars] lost event: [chars]

Explanation    The specified process failed to receive an event that was sent to it.

Recommended Action    If any problems are seen, they may nbe rectified by restarting the process using the 'process restart' command.

Error Message     
 
    
    
   

%L2-FSYNC-4-QLT_TIMER Failed to [chars] the [chars] timer for [chars]: [chars]

Explanation    *SUPPORT*

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-SELECTION_ERROR Failed to handle selection update for selection point [chars]: [chars]

Explanation    The Frequency Synchronization manager that generated the message encountered an error during handling of an update to the inputs selected at the specified selection point. The message contains more details of the error. The change to which inputs are selected, or to the QL or priority of the selected input, may not take effect.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-SHUTDOWN_CHECK_FAILED Could not determine whether to exit: [chars]

Explanation    A Frequency Synchronization process could not determine whether all Frequency Synchronization configuration has been removed and so cannot exit safetly. Frequency Synchronization processes may be running despite no Frequency Synchronization configuration existing.

Recommended Action    No action is required. If the message continues to be seen, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-4-SIGNAL_UPDATE_FAILED Failed to create object representing signal from [chars] to local Selection Point [chars]: [chars]

Explanation    The Frequency Synchronization manager that generated the message failed to update its database, either in response to a message received from a remote Frequency Synchronization manager on another node, or after a change to the selected inputs in another selection point on this node. This is most likely due to an out-of-resource condition. The corresponding frequency signal will not be used.

Recommended Action    Resolve the underlying resource issue, then restart the Frequency Synchronization manager on the affected node using the following command: process restart fsyncmgr location node

Error Message     
 
    
    
   

%L2-FSYNC-4-TIMER_FAILED Failed to process a timer event: [chars]

Explanation    A Frequency Synchronization process has failed to process a timer event.

Recommended Action    The process will exit and will be restarted. If the problem persists, Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-FSYNC-6-SELECTION_CHANGE New selection for selection point [chars]: [unsigned int] inputs selected[chars]

Explanation    A new set of inputs has been selected at the specified selection point, to drive the output of the selection point.

Recommended Action    This message is for information only, no further action is required.

Error Message     
 
    
    
   

%L2-FSYNC-6-SELECTION_FALLBACK Selection point [chars] is no longer externally synchronized: [chars]

Explanation    There is no longer a line or external source available for the specified selection point, so it has fallen back to the internal oscillator if available, or otherwise disabled the outputs.

Recommended Action    This message is for information only, no further action is required.

FWD_EDGE_COMMON Messages

Error Message     
 
    
    
   

%L2-FWD_EDGE_COMMON-3-EDGE_ADJ_ERR adj engine layer internal error [chars] : [chars]

Explanation    A runtime failure occurred in adjacency engine layer resulting in a failure to provide some system service as indicated in the message text. This is most likely an internal error. %s - indicates the reason for the failure. %s - is the decoded error reason.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-FWD_EDGE_COMMON-3-EDGE_ADJ_ERR adj engine layer internal error [chars] : [chars]

Explanation    A runtime failure occurred in adjacency engine layer resulting in a failure to provide some system service as indicated in the message text. This is most likely an internal error. %s - indicates the reason for the failure. %s - is the decoded error reason.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-FWD_EDGE_COMMON-3-EDGE_ADJ_NULL Adjacency HW pointer is NULL for path [dec] fwd_type [dec]

Explanation    A runtime failure occurred in fib ip engine layer resulting in a failure to provide some system service as indicated in the message text. This is most likely an internal error. path %d - indicates the path index fwd_type %d - the forward type

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-FWD_EDGE_COMMON-3-EDGE_IP_ERR fib ip engine layer internal error [chars] : [chars]

Explanation    A runtime failure occurred in fib ip engine layer resulting in a failure to provide some system service as indicated in the message text. This is most likely an internal error. %s - indicates the reason for the failure. %s - is the decoded error reason.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-FWD_EDGE_COMMON-3-EDGE_IP_ERR fib ip engine layer internal error [chars] : [chars]

Explanation    A runtime failure occurred in fib ip engine layer resulting in a failure to provide some system service as indicated in the message text. This is most likely an internal error. %s - indicates the reason for the failure. %s - is the decoded error reason.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

GATM Messages

Error Message     
 
    
    
   

%L2-GATM-2-ERR [chars] - [dec]: [chars]

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-GATM-2-ERR_HEX [chars] - [dec]: [chars] ([hex])

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-GATM-2-ERR_IFH_STS [chars] - [dec]: [chars] ifh equals [hex] rc equals [hex]

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-GATM-2-ERR_INT [chars] - [dec]: [chars] ([dec])

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-GATM-2-ERR_STR [chars] - [dec]: [chars] ([chars])

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-GATM-2-ERR_STS [chars] - [dec]: [chars] (rc equals [hex])

Explanation    Error in gatm operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

GDO Messages

Error Message     
 
    
    
   

%L2-GDO-5-L2PORT_FAULT_NOTIFY [chars]

Explanation    ATM SPA GDO L-AIS insertion/removal notification messages

Recommended Action    *NONE*

Error Message     
 
    
    
   

%L2-GDO-7-DEBUG [chars]

Explanation    ATM SPA GDO L-AIS insertion/removal debug messages

Recommended Action    *NONE*

GE_ASIC_PRP3 Messages

Error Message     
 
    
    
   

%L2-GE_ASIC_PRP3-3-INIT_ERR GigE hardware initialization failed. Reason equals [chars], Error Decode equals [chars]

Explanation    The GE hardware managment subsystem encountered an error during initialization. This process monitors and controls hardware components required for the RP management ethernet port. A failure in this subsystem will disable the the RP's onboard ethernet. %s - indicates the reason for the failure %s - indicates the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process ge_mgmt' to verify that the process is up and running. If it is not, try doing 'process restart ge_mgmt' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GE_ASIC_PRP3-3-PKT_ERR GigE hardware packet error. Reason equals [chars]

Explanation    The GE hardware managment subsystem encountered an error during receiving of packets. This process monitors and controls hardware components required for the RP management ethernet port. A failure in this subsystem will disable the the RP's onboard ethernet. %s - indicates the reason for the failure

Recommended Action    Execute 'show process ge_mgmt' to verify that the process is up and running. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

GE_ASIC Messages

Error Message     
 
    
    
   

%L2-GE_ASIC-3-INIT_ERR GigE hardware initialization failed. Reason equals [chars], Error Decode equals [chars]

Explanation    The GE hardware managment subsystem encountered an error during initialization. This process monitors and controls hardware components required for the RP management ethernet port. A failure in this subsystem will disable the the RP's onboard ethernet. %s - indicates the reason for the failure %s - indicates the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process ge_mgmt' to verify that the process is up and running. If it is not, try doing 'process restart ge_mgmt' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

GE Messages

Error Message     
 
    
    
   

%L2-GE-3-INIT_ERR PRP Gigabit Ethernet execution agent initialization failed. [chars]/[chars]

Explanation    The PRP Gigabit ethernet execution agent failed to initialize. The PRP gigabit ethernet execution agent provides the support for packet forwarding over the GE port present on the Performance Route Processor. A failure of this execution agent likely means that packets being sent to or from the PRP's GE ports are going to be lost. %s - indicates the reason for the failure %s - is the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process ge_mgmt location 0/x/cpu0' to verify that the process is up and running. If it is still non-operational, try doing 'process restart ge_mgmt location 0/x/cpu0' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

GSR_aib Messages

Error Message     
 
    
    
   

%L2-GSR_aib-3-RES_ERROR Error: [chars]: Err equals [chars]

Explanation    A error occurred in GSR aib Driver resulting in a failure to provide some system service as indicated in the message text. This is most likely any internal error. %s - reason for the failure. %s - dll causing the error.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-GSR_aib-6-INFO_MSG Info: [chars]

Explanation    This is a Informational message in the GSR aib driver to indicate an operation.

Recommended Action    No action is required.

GSR_edge_fwd_lib Messages

Error Message     
 
    
    
   

%L2-GSR_edge_fwd_lib-3-RES_ERROR [chars]: Err equals [chars]

Explanation    An error occurred in Edge fowarding lib resulting in a failure to provide some system service as indicated in the message text. %s - indicates the reason for the failure. %s - is the decoded error reason. This error indicates there is problem in LC Forwarding resources

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

GSR Messages

Error Message     
 
    
    
   

%L2-GSR-3-ERR_MEM_ALLOC Memory allocation failed for internal data storage

Explanation    Memory was not available for an internal data structure. The requested operation could not be accomplished because of a low memory condition. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Reload the LC using 'hw-module' command. If the problem recurs, reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. Also ensure the LC is populated with the minimum amount of memory required for proper operation.

Error Message     
 
    
    
   

%L2-GSR-3-ERR_SF_RESET [chars] : Hardware initialization of Fabric interface ASIC failed. Node will be reloaded for recovery after collecting diag information

Explanation    During boot-up or fabric configuration change or error handling, there was a problem in the initialization of fabric interface ASIC. Problem causes the node to be reloaded and will be restored by itself.

Recommended Action    Call your Cisco technical support representative and provide the gathered information. Node will be reloaded and restored in short time.

Error Message     
 
    
    
   

%L2-GSR-3-ERR_THREAD_CREATE Internal OS call to create additional threads failed, [chars]

Explanation    An internal OS library returned an error. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a OS kernel problem on the card. The LC will not boot up successfully and will not be able to participate in data forwarding. This condition can impact various processes on the LC. The LC is in unstable condition.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-ERR_THREAD_CREATE Internal OS call to create additional threads failed, [chars]

Explanation    An internal OS library returned an error. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a OS kernel problem on the card. The LC will not boot up successfully and will not be able to participate in data forwarding. This condition can impact various processes on the LC. The LC is in unstable condition.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_CHKPT Call to checkpoint library failed, status equals [chars]

Explanation    An internal support library returned an error. The driver was not able to save data for restart ability. A restart of the FIAD process may not be NSF compliant. Any software upgrade requiring FIAD to be restarted will result in traffic loss. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a OS kernel problem on the card.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_CHKPT_DATA_EXISTS The driver is coming up in normal mode, but checkpoint information already exists.

Explanation    When a driver comes up in NORMAL_MODE, checkpointing data should not already exist. This indicates a mismatch in the driver state. The checkpointed data may be corrupted on the LC. Restart ability of processes may be affected.

Recommended Action    The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_CHKPT_RECOVERY_NODATA The driver is coming up in restart mode, but the checkpoint info does not exist.

Explanation    When a driver comes up in RECOVERY_MODE, checkpointing data should have already been saved to the checkpointing record by the previous life of the driver. This can impact the drivers ability to restart without affecting traffic.

Recommended Action    The system may not recover from this error automatically. A reload of the linecard should be initiated in order to recover. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_DEVCTL_ERR Unsupported devctl case [dec]

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_DLOPEN Failed to load [chars]

Explanation    The library (dll) named could not be found or there was an error while loading. Indicates a software installation problem. The LC will not boot up successfully and will not be able to participate in data forwarding.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_INT_ATTACH Internal OS call to process interrupts failed

Explanation    An internal OS library returned an error. Some error conditions on the LC may not be reported correctly. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a OS kernel problem on the card.

Recommended Action    The system will normally recover from this error without intervention. This error indiactes a more fundamental issue on the LC. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_MEM_CHIP_ERR ([chars]): no memory for chip data.

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_MEM_ERROR ([chars]): FIA failed to initialize memory. Exiting

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_MMAP_ERROR ([chars]): FIA memory mapping failed. Exiting

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_NOT_RESET FIA was not reset before programming

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_STARTUP_DATA ([chars]), Illegal size of input for FIA startup data structure

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_SYNC_ERROR ([chars]): FIA failed to sync, los_status [hex], los_error [hex], fia_config [hex]

Explanation    This error usually indicates an internal hardware problem on the card.

Recommended Action    If there are other error reports about the switch fabric (CSC/SFC) then wait several minutes for corrective action. Otherwise, run diagnostics for slot reporting error. Use 'diag slot verbose' command. (This command may not work for the slot containing the primary route processor.) If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_UNHALT Could not unhalt [chars]

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_UNSUPPORTED_CDB Unsupported cdb version

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FIA_UNSUPPORTED_OPAQUE_DATA Unsupported opaque data version

Explanation    An unexpected error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-FS_ERR1 [chars] : [hex]

Explanation    EE192 SerDes retimer driver error. An internal OS library returned an error. The system will usually recover from this error automatically. If the frequency of this alert increases noticeably it could indicate a OS kernel problem on the card. The LC will not boot up successfully and will not be able to participate in data forwarding. This condition can impact various processes on the LC. The LC is in unstable condition.

Recommended Action    The system will normally recover from this error without intervention. This error indiactes a more fundamental issue on the LC. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information.

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR_HW [chars] : [chars] : [hex]

Explanation    EE192 Spabrg driver error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.'

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR2_HW [chars] : [chars] : [hex] [hex]

Explanation    EE192 Spabrg driver error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.'

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR3_HW [chars] : [chars] : [hex] [hex] [hex]

Explanation    EE192 Spabrg driver error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.'

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR4_HW [chars] : [hex] [hex]

Explanation    EE192 Spabrg driver error

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.'

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR5_HW [chars] : [chars] : [hex] [hex]

Explanation    EE192 Spabrg driver single-bit error

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR6_HW [chars] : [chars] : [hex] [hex] [hex]

Explanation    EE192 Spabrg driver single-bit error

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-3-SPABRG_ERR7_HW [chars] : [hex] [hex]

Explanation    EE192 Spabrg driver error

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-4-ERR_SYSDB_SET system database item set failed [chars]

Explanation    Error in communication channel with the system database. There was a problem accessing the named item. This could be a temporary problem caused by an outage in the connection to the server. The connection will be restored, but the operation itself was aborted.

Recommended Action    Call your Cisco technical support representative and provide the gathered information. Copy the output of the following commands exactly as they appear. show processes fiad location X/X/X

Error Message     
 
    
    
   

%L2-GSR-4-FIA_EDM system database access failed [chars]

Explanation    Error in communication channel with clients. There was a problem accessing the system database item. This could be a temporary problem caused by an outage in the connection to the server. The connection will be restored, but the operation itself was aborted.

Recommended Action    Call your Cisco technical support representative and provide the gathered information. Copy the output of the following commands exactly as they appear. show processes fiad location X/X/X

Error Message     
 
    
    
   

%L2-GSR-6-FIA_INFO_MSG [chars]

Explanation    This is a Informational message in the FIA Driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-6-FIA_PCDS_FAILURE [chars] failed, slot equals [dec], error info equals [chars]

Explanation    This is a message indicating FIA PCDS failure.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-6-PCDS_STATS_TIMESTAMP_FAILURE pcds_get_timestamp failed for fishstick stats

Explanation    This is a message indicating failed to get timestamp for fishstick stats.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-GSR-6-SPABRG_CRIT_INFO [chars] : [chars] : [hex]

Explanation    EE192 Spabrg driver critical info

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-GSR-6-SPABRG_INFO1_HW [chars] : [chars] : [hex]

Explanation    EE192 Spabrg driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-GSR-6-SPABRG_INFO2_HW [chars] : [chars] : [hex], [hex]

Explanation    EE192 Spabrg driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-GSR-6-SPABRG_INFO3_HW [chars] : [chars] : [hex], [hex], [hex]

Explanation    EE192 Spabrg driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-GSR-7-FIA_FCTL [chars] failed, slot equals [dec], error info equals [chars]

Explanation    An interprocess call returned an error. Possibly a timeout. The central switch fabric software may not recognize the LC that exhibits this error. Maintenance bus may not be operating as desired.

Recommended Action    Look for other fctl messages. Wait for corrective action. The system will normally recover from this error without intervention. If the frequency with which this error is occurring increases substantially, call your Cisco technical support representative and provide the gathered information. Copy the output of the following commands exactly as they appear. show processes fctl show processes fiad location X/X/X show diag X/X/X show diag chassis-info

GT64115 Messages

Error Message     
 
    
    
   

%L2-GT64115-2-PCI_CONFIG Fatal error: [chars]: [dec]

Explanation    A fatal error occurred during GT64115 PCI Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GT64115-2-PCI_INIT Fatal error: [chars]

Explanation    A fatal error occurred during GT64115 PCI Driver initialization

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-GT64115-3-PCI_BRIDGE_INTR PCI Bridge Intr: [chars] [dec] [dec]

Explanation    This is an error message resulted from an interrupt from the PCI device.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

gulf Messages

Error Message     
 
    
    
   

%L2-gulf-3-FATAL_ERROR Fatal error: [chars]: [chars]: [dec]

Explanation    A fatal error occurred in gulf Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-gulf-4-WARNING warning: [chars]: [chars]: [dec]

Explanation    A warning condition is detected in gulf Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-gulf-6-INFO_MSG Info: [chars]: [chars]: [dec]

Explanation    This is a Informational message in the gulf driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-gulf-7-DEBUG_MSG Debug: [chars]: [chars]: [dec]

Explanation    This is a debug message in the gulf driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

HALE_MQS Messages

Error Message     
 
    
    
   

%L2-HALE_MQS-3-ERR_MEM_ALLOC [chars] , [chars]

Explanation    This message indicates a failure in allocating memory for MQS extension. The causes for this error could be lack of memory or a hardware resource.

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

HALE_QOS Messages

Error Message     
 
    
    
   

%L2-HALE_QOS-3-ERR_COMMIT Route ([chars],[chars])

Explanation    This message indicates a failure in committing route (S, G). This means QoS feature will not be applied for the specified route; Traffic through this route would go to the default queue. The causes for this error could be lack of memory, a hardware resource limitation, or an internal error. %s,%s - indicates the (S, G)

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. Retry the QoS configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HALE_QOS-3-ERR_MEM_ALLOC [chars] , [chars]

Explanation    This message indicates a failure in allocating memory for QOS extension. The causes for this error could be lack of memory or a hardware resource limitation.

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

HALE_REPLICORD Messages

Error Message     
 
    
    
   

%L2-HALE_REPLICORD-3-ERR_MEM_ALLOC [chars] , [chars]

Explanation    This message indicates a failure in allocating memory for replicorder extension. The causes for this error could be lack of memory or a hardware resource limitation.

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

HALE_TCAM Messages

Error Message     
 
    
    
   

%L2-HALE_TCAM-3-ERR_MEM_ALLOC [chars] , [chars]

Explanation    This message indicates a failure in allocating memory for TCAM extension. The causes for this error could be lack of memory or a hardware resource limitation.

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HALE_TCAM-3-ERROR [chars]: [chars]

Explanation    A SW exception occurred in TCAM extension Library

Recommended Action    If TCAM memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration.

HALE_TLU Messages

Error Message     
 
    
    
   

%L2-HALE_TLU-3-ERR_MEM_ALLOC [chars] , [chars]

Explanation    This message indicates a failure in allocating memory for TLU extension. The causes for this error could be lack of memory or a hardware resource limitation.

Recommended Action    If memory is the issue, reduce other system activity to ease memory demands. If conditions warrant and minimum memory requirements not met, upgrade to a larger memory configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

HFA_COMMON Messages

Error Message     
 
    
    
   

%L2-HFA_COMMON-3-FATAL_ERR Fatal error: [chars]: Err equals [chars]

Explanation    A fatal error occurred in HFA common Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_COMMON-4-ANOMALY [chars]

Explanation    A SW exception of unexpected condition or an out of resources (memory, HW profiles, etc) situation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_COMMON-6-INFO_MSG [chars] [chars]

Explanation    This is a Informational message in the HFA common Driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-HFA_COMMON-6-INFO_WARNING [chars] err [hex]

Explanation    This is a Informational message in the HFA common Driver to indicate an operation.

Recommended Action    No action is required.

HFA_LIB Messages

Error Message     
 
    
    
   

%L2-HFA_LIB-3-ANOMALY [chars]

Explanation    Software exception. Quite probably a SW bug.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-3-BLWM_CLIENT_CONF_FAILED hfa: blwm client configuration failed, error: [hex] [chars]

Explanation    Unable to configure BLWM client functionality.Will not be able to send any BLWM mesages from HFA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-3-BLWM_CLIENT_REBIND_FAILED hfa: blwm client rebind failed, error: [hex] [chars]

Explanation    Unable to rebind with BLWM client functionality after a connection reconnect. Will not be able to send any BLWM mesages from HFA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-3-BLWM_MSG_SEND_FAILED hfa: blwm msg send/flush: retried: [dec] time(s), failed to send, error: [hex] [chars]

Explanation    Unable to send/flush a BLWM message to the HFA server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-3-BLWM_RECVD_REPLY_FAIL hfa: Received a failure reply code for a batched request, reply code: [dec]

Explanation    This is the message printed by the default handler installed by HFA to process the replies received for batched requests. The default handler's behavior is to just print this message. The BLWM might be processed completely but the return code in the reply message indicates failure. The application should install its own handler to handle the replies to batched requests.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-3-MSG_SEND_FAILED hfa: msg: [dec], retried: [dec] time(s), failed to send, errno: [chars]

Explanation    Unable to send a message to the HFA server.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-4-BLWM_REPLAY_REQUEST hfa: Replaying a batched request of type [dec] that might have been partially processed before.

Explanation    Due to a server restart, a batched request might have been partially processed. The default handler installed by HFA simply replays the request. Applications that can not afford to replay a request should install their own handler.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-4-ERR_LOCK [chars] error on [chars], rc equals [dec]

Explanation    An error occurred when un/locking HFA HW. Some of the Harware programming may be inconsistent.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-HFA_LIB-6-INFO_WARNING [chars]: [dec]

Explanation    This is a Informational message in the HFA client LIB to indicate an operation.

Recommended Action    Debug message only. No action is required.

if_discovery Messages

Error Message     
 
    
    
   

%L2-if_discovery-3-FATAL_ERROR Fatal error: [chars]: [chars]: [dec]

Explanation    A fatal error occurred in plim pos 4p oc12 Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-if_discovery-6-INFO_MSG Info: [chars]: [chars]

Explanation    This is a Informational message in the plim pos 4p oc12 driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-if_discovery-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the plim pos 4p oc12 driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

IGMPSN_POLICY Messages

Error Message     
 
    
    
   

%L2-IGMPSN_POLICY-3-ORA_INSTBUILD Failed to build [chars]: [chars] ([chars])

Explanation    Internal error in the routing policy library.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN_POLICY-3-ORA_ORABUILD Failed to build ORA[chars]: [chars] ([chars])

Explanation    There was an internal error in the routing policy library.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN_POLICY-3-ORA_RUN Could not apply policy operation [chars] to attribute [chars] because [chars]

Explanation    Internal error in the routing policy library.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

IGMPSN Messages

Error Message     
 
    
    
   

%L2-IGMPSN-3-DP_CONGESTION Layer 2 multicast data plane programming congestion

Explanation    Applications are providing state change to the layer 2 multicast data plane hardware faster than the hardware can be programmed. Internal message to the hardware have been dropped such that IGMP snooping state is now out of sync with the hardware. The user must slow the rate of IGMP state change being received by the system. The system will automatically recover from this condition once the rate of IGMP state change has been reduced.

Recommended Action    The user must slow the rate of IGMP state change being received by the system. The system will automatically recover from this condition once the rate of IGMP state change has been reduced.

Error Message     
 
    
    
   

%L2-IGMPSN-3-ERR_INIT Initialization failed: [chars], [chars]

Explanation    An error occurred during initialization.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN-3-INIT Initialization failed: [chars]

Explanation    An error occurred during initialization.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN-3-NET_ERR [chars] : [chars]

Explanation    Internal error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN-3-SOCK_ERR [chars] : [chars]

Explanation    Internal error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN-3-SYSDBINIT Error initializing the system database: [chars]

Explanation    An error occurred when initializing the system database.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IGMPSN-5-DP_CONGESTION_CLEAR Layer 2 multicast data plane programming congestion cleared

Explanation    The layer 2 multicast data plane hardware programming has been resynced with the state in the IGMP snooping application.

Recommended Action    The system is attempting to recover from a layer 2 multicast data plane programming congestion condition. No user action is required.

IOB Messages

Error Message     
 
    
    
   

%L2-IOB-3-INTR IOB Intr: [chars]

Explanation    The IOB FPGA has been interrupted due to an access fault

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IOB-5-UNKNOWN_INTR IOB Intr: [chars]: [dec]: [dec]

Explanation    This is a message in the IOB FPGA driver to indicate that it has detected an unknown interrupt.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

IPV6_EA Messages

Error Message     
 
    
    
   

%L2-IPV6_EA-3-INIT Failed to initialize [chars], because of [chars]

Explanation    Initialization process such as getting an evm failed.

Recommended Action    sysmgr will retry to start the hfrlc_ipv6_ea. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%L2-IPV6_EA-3-INIT Failed to initialize [chars], because of [chars]

Explanation    Initialization process such as getting an evm failed.

Recommended Action    sysmgr will retry to start the ipv6_ea. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%L2-IPV6_EA-3-NOMEM IPv6 EA failed to program '[chars]' due to low memory

Explanation    The IPv6 EA process could not allocate memory needed to program some IPv6 feature.

Recommended Action    Check memory status.

Error Message     
 
    
    
   

%L2-IPV6_EA-3-PLAT_UPD_FAILED Platform update failed: [chars] - [chars](CH[hex])

Explanation    Platform update failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IPV6_EA-3-PLAT_UPD_FAILED_GL Platform update failed for [dec] interface: [chars] - [chars]

Explanation    Platform update failed for all interfaces in a batch.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IPV6_EA-4-ERROR [chars]: [chars]

Explanation    There was an error with processing an event in the EA.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

IXP2800_FWD Messages

Error Message     
 
    
    
   

%L2-IXP2800_FWD-3-IPCP_FAILURE Function [chars] failure errno [chars]

Explanation    IPCP communication failure.

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_FWD-3-NONFATAL_ERROR Nonfatal error: [chars] error code [dec]

Explanation    This is a error message of the IXP2800 forwarding driver to indicate either anomalies which are not fatal. Some of the messages may indicate a failure to allocate resources needed by applications.

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_FWD-7-LOG_FILE_ERROR Test DLL failed to open log file [chars] ([chars])

Explanation    The NPU test DLL failed to open the log file

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_FWD-7-UNEXPECTED_FUNC_INVOC Function [chars] invoked

Explanation    An unexpected function invocation occured

Recommended Action    None

IXP2800_HW Messages

Error Message     
 
    
    
   

%L2-IXP2800_HW-2-NOMEM ixp2800 HW driver Could not allocate memory

Explanation    'ixp2800 HW driver has failed to aquire the required amount of memory.'

Recommended Action    *REDUCE*

Error Message     
 
    
    
   

%L2-IXP2800_HW-3-FATAL_ERROR [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A fatal error occurred in IXP2800_HW Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IXP2800_HW-4-WARNING [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A warning condition occurred in IXP2800_HW Driver which involves exiting the process.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-IXP2800_HW-6-INFO [chars]

Explanation    SERVICE card ixp2800_hw driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-IXP2800_HW-7-LOG_FILE_ERROR ixp2800 HW driver DLL failed to open log file [chars] ([chars])

Explanation    The NPU HW driver DLL failed to open the log file

Recommended Action    None

IXP2800_SERVICE Messages

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-2-NOMEM ixp2800 service Could not allocate memory

Explanation    'ixp2800 service has failed to aquire the required amount of memory.'

Recommended Action    *REDUCE*

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-3-FATAL_ERROR [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A fatal error occurred in IXP2800_SERVICE Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-3-HOST_SPU_ERROR [chars] Fatal error - [chars]

Explanation    A fatal error occurred in SPU common Driver

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-3-IPCP_FAILURE Function [chars] failure errno [chars]

Explanation    IPCP communication failure.

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-4-WARNING [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A warning condition occurred in IXP2800_SERVICE Driver which involves exiting the process.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-6-INFO [chars]

Explanation    SERVICE card ixp2800_service driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-IXP2800_SERVICE-7-LOG_FILE_ERROR ixp2800 service DLL failed to open log file [chars] ([chars])

Explanation    The NPU service DLL failed to open the log file

Recommended Action    None

IXP2800_VFW Messages

Error Message     
 
    
    
   

%L2-IXP2800_VFW-2-NOMEM ixp2800 service Could not allocate memory

Explanation    'ixp2800 vFW service has failed to aquire the required amount of memory.'

Recommended Action    *REDUCE*

Error Message     
 
    
    
   

%L2-IXP2800_VFW-3-FATAL_ERROR [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A fatal error occurred in IXP2800_SERVICE Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-IXP2800_VFW-3-IPCP_FAILURE Function [chars] failure errno [chars]

Explanation    IPCP communication failure.

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_VFW-3-NONFATAL_ERROR Nonfatal error: [chars] error code [dec]

Explanation    This is a error message of the IXP2800 service driver to indicate either anomalies which are not fatal. Some of the messages may indicate a failure to allocate resources needed by applications.

Recommended Action    None

Error Message     
 
    
    
   

%L2-IXP2800_VFW-4-WARNING [chars]()[[dec]]: [chars]: [chars] ([dec])

Explanation    A warning condition occurred in IXP2800_SERVICE Driver which involves exiting the process.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-IXP2800_VFW-6-INFO [chars]

Explanation    SERVICE card ixp2800_service driver informational message

Recommended Action    NONE : Informational message only

Error Message     
 
    
    
   

%L2-IXP2800_VFW-7-LOG_FILE_ERROR ixp2800 service DLL failed to open log file [chars] ([chars])

Explanation    The NPU service DLL failed to open the log file

Recommended Action    None

JACKET Messages

Error Message     
 
    
    
   

%L2-JACKET-3-CRITICAL_ERROR [chars]: [chars]: [hex]

Explanation    A critical error occurred in jacket driver which involves exiting the process. The jacket driver will restart and unless the same error occurs on the next attempt the driver will function normally. If the error is persistent, it indicates the system error or HW error which needs further investigation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-JACKET-3-PIO_CRITICAL_ERROR Asic PIO failure : [chars], instance [dec]: rc [dec] cerr [chars] errno [dec] data1 [hex] data2 [hex]

Explanation    A critical error occurred while accessing the hardware in jacket driver which involves exiting the process. The driver will restart and attempt normal functionality. If the error is transient, the jacket driver and the SPAs will continue normal operation. If the error is persistent, the jacket card hardware needs to be checked out for access failures.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-JACKET-3-RULES_CRITICAL_ERROR SPA subslot [dec]: FAILED: [chars] for [chars]

Explanation    A critical error occurred in jacket driver rules validation for a SPA which results in the SPA not being enabled. This does not affect the other slots on the jacket card. Please check the SW support for the SPA slot for which this message is seen.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-JACKET-3-SPA_DISABLE [dec] requests to disable SPA [dec] due to spa bus error

Explanation    This is an error message indicating a Hardware access error for a SPA and disable the SPA to avoid LC reload

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JACKET-3-SPA_PIO_ERROR SPA subslot [dec]: had [chars] error when accessing address [hex] with fault code [dec]

Explanation    This is an error message indicating a Hardware access error for a SPA. If this is a recurrent message, it usually is due to faulty hardware, loose connection at the SPA connector on the jacket card. Try reseating the SPA and see if the issue is resolved. If not, please check with TAC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JACKET-3-SPA_SELF_DESTRUCT [chars] has requested to disable SPA [dec] due to spa bus error

Explanation    This is an error message indicating a Hardware access error for a SPA. If this is a recurrent message, it usually is due to faulty hardware, loose connection at the SPA connector on the jacket card. Try reseating the SPA and see if the issue is resolved. If not, please check with TAC.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JACKET-6-EVENT_INFO SPA subslot [dec]: [chars] for [chars], driver [chars]

Explanation    This is an informational message in the jacket driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JACKET-6-INFO [chars]: [chars]

Explanation    This is an informational message in the jacket driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JACKET-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the jacket driver to indicate anomolies which are not critical. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

JDAM Messages

Error Message     
 
    
    
   

%L2-JDAM-3-FATAL_ERROR Fatal error: [chars]: [chars]: [dec]

Explanation    A fatal error occurred in JDAM Driver which involves exiting the PLIM process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-JDAM-6-INFO_MSG [chars] [chars] [dec]

Explanation    This is a Informational message in the JDAM driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-JDAM-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the JDAM driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2C Messages

Error Message     
 
    
    
   

%L2-L2C-3-ERR_MISCONFIG Misconfiguration: Item [chars] on interface [chars] is incompatible with other configuration. The system may now be in an inconsistent state.

Explanation    The L2VPN Uberverifier has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier cannot correct this.

Recommended Action    The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2C-4-WARN_EVENT Event loop error: [chars]

Explanation    The L2VPN Uberverifier has encountered a problem in its event loop and cannot continue. In this situation it should restart.

Recommended Action    The L2VPN Uberverifier should recover on restart. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2C-4-WARN_INIT Failed to initialize [chars]: [chars]

Explanation    The L2VPN Uberverifier process failed to initialize correctly. In this situation it restarts, but may not recover if there is a persistant error in the IOS-XR system and the L2VPN Uberverifier is later unable to reestablish its connections and initialize successfully.

Recommended Action    The Uberverifier is not essential for system operation. However, if it is not running as intended, it may be possible for a misconfiguration to be allowed. If this persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2FIB_DEBUG Messages

Error Message     
 
    
    
   

%L2-L2FIB_DEBUG-3-ERR [chars]: [chars]

Explanation    Some error occurred in operations related to Shared Memory area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2FIB_LIB Messages

Error Message     
 
    
    
   

%L2-L2FIB_LIB-2-OOR L2FIB has run out of [chars] resource memory. No more updates will be handled by the L2FIB. Please delete ACs to resume normal operation on this node

Explanation    The l2fib_mgr process on the node has detected an out of resource condition for the indicated resource. Normal operation cannot resume until routes are deleted.

Recommended Action    Run show l2vpn forwarding resource command and check which resource(s) are running low on memory. Significant ACs will have to be deleted on the affected node to resume normal l2fib operation.

Error Message     
 
    
    
   

%L2-L2FIB_LIB-3-ERR [chars]

Explanation    Some error occurred in operations related to L2FIB API area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB_LIB-3-SHM_ERR [chars] failed: [chars]

Explanation    Some error occurred in operations related to Shared Memory area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB_LIB-4-RSRC_LOW L2FIB running low on [chars] resource memory. L2FIB will now begin resource constrained forwarding. Only route deletes will be handled in this state, which may result in mismatch between L2VPN mgr/AIB/L2FIB and L2FIB. Traffic loss on certain ACs can be expected. The L2FIB will automatically resume normal operation, once the resource utilization returns to normal level

Explanation    The l2fib_mgr process has detected that average utilization for specified resource has risen above a predefined high watermark value, and has entered resource contrained forwarding mode. In this mode, the l2fib will only handle route deletes which may potentially freeup some memory. Due to this operational mode, the L2VPN mgr/AIB/L2FIB and L2FIB will be out of sync. Once ACs are deleted and resource utilization level drops to acceptable levels again, l2fib will come out of this operational mode and resume normal operation.

Recommended Action    Run show l2vpn forwarding resource command and check which resource(s) are running low on memory. Any action that reduces number of ACs will eventually result in the l2fib returning to normal operation after few seconds.

Error Message     
 
    
    
   

%L2-L2FIB_LIB-6-BDXC_SEND [chars]

Explanation    An IPC between L2FIB and its client process failed; the message will be retried. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2FIB_SHM Messages

Error Message     
 
    
    
   

%L2-L2FIB_SHM-2-INIT L2FIB initialization failed: [chars]

Explanation    Initialization of L2FIB failed. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB_SHM-3-ERR [chars] failed: [chars]

Explanation    Some error occurred in operations related to Shared Memory area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2FIB Messages

Error Message     
 
    
    
   

%L2-L2FIB-2-INIT L2FIB initialization failure: [chars] [chars]

Explanation    L2FIB initialization failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-2-INVALID_MSG L2FIB thread [chars] received an invalid message: [chars] [unsigned int]

Explanation    L2FIB thread got an invalid message so it is exiting

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-2-SHM_INIT L2FIB shared memory initialization failed: [chars]

Explanation    Initialization of L2FIB failed. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-3-SHM_ERR [chars] failed: [chars]

Explanation    Some error occurred in operations related to Shared Memory area. The text of the message displays the failed operation and the related error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-3-WAVL_ERR [chars] failed (tree equals [chars])

Explanation    Some error occurred in WAVL operations The text of the message displays the failed operation and the related wavl tree. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-6-GEN_INFO_CERR [chars]: [chars]

Explanation    An internal software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-6-GEN_INFO_ERR [chars]

Explanation    An internal software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2FIB-6-MAC_TABLE_RESYNC_COMPLETE The resynchronization of the MAC address table is complete

Explanation    The command to resynchronize the MAC address table may take a while to complete. This message indicates that resynchronization is complete and the MAC address table can be displayed..

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2FIB-6-XC_MOD XC/BP delete-and-create: [chars]

Explanation    The L2VPN provision message is handled by deleting old XC/BP, and creating a new one.

Recommended Action    None.

L2TP Messages

Error Message     
 
    
    
   

%L2-L2TP-2-INIT L2TP initialization failure: [chars] [chars]

Explanation    L2TP initialization failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2TP-3-GEN_ERR L2TP internal error: [chars]

Explanation    An internal software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2TP-3-IPC_ERR L2TP IPC transport error: [chars] [chars]

Explanation    An IPC transport software error occurred

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2VPN_DEBUG Messages

Error Message     
 
    
    
   

%L2-L2VPN_DEBUG-3-ERR [chars]: [chars]

Explanation    Debug and ltrace library initialization failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

L2VPN_PW Messages

Error Message     
 
    
    
   

%L2-L2VPN_PW-3-INVALID Error [chars]

Explanation    AToM getting invalid provision

Recommended Action    This is not expected and fatal.

Error Message     
 
    
    
   

%L2-L2VPN_PW-3-NOPRIMARY Pseudowire with address [chars], id [unsigned long int], [chars]

Explanation    The L2VPN Backup Pseudowire couldn't find it's primary PW.

Recommended Action    This is not expected and fatal.

Error Message     
 
    
    
   

%L2-L2VPN_PW-3-UPDOWN Pseudowire with address [chars], id [unsigned long int], state is [chars]

Explanation    The L2VPN Pseudowire went up or down

Recommended Action    If the state change was unexpected, confirm the configuration settings for the cross-connect.

L2VPN Messages

Error Message     
 
    
    
   

%L2-L2VPN-2-CRIT_MEM_SHUT [chars] process shutting down due to 'Critical' memory state.

Explanation    The system has notified a process that it is critically short of memory and the process is shutting down.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-3-BAG_REG_ERR bag(s) registration failed: [chars]

Explanation    Some error occured while trying to register edm bags. The text of the message displays the failed operation with error code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-3-EVENT_ERR [chars] failed: [chars]

Explanation    Some error occured in event/event manager/event connection operations. The text of the message displays the failed operation with error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-3-GEN_ERR [chars] failed: [chars]

Explanation    Some requested operation failed. The text of the message displays the failed operation with error code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-3-INTERNAL_ERROR L2VPN sanity check failed for Pseudowire ID [chars] pw-id [unsigned long int]: [chars]. Limit is [dec]

Explanation    An internal error has been encountered and the Pseudowire cannot be established.

Recommended Action    Please provide the exact error message seen on the console, collect a core dump of the running l2vpn_mgr process, and the show tech-support l2vpn output for further analysis of the error condition and potential recovery

Error Message     
 
    
    
   

%L2-L2VPN-3-SYSDB_BIND_ERR sysdb_bind failed for '[chars]': [chars]

Explanation    Some error occured in sysdb bind operation bind. The text of the message displays the failed operation for the bindpoint with error code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-3-SYSDB_ERR [chars] failed: [chars]

Explanation    Some error occured in sysdb operation. The text of the message displays the failed operation with error code. The traceback can be used to get the function/line number of error generating code.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-L2VPN-4-BRIDGE_MTU_MISMATCH [chars] mtu of [dec] does not match bridge mtu of [dec]

Explanation    The interface MTU does not match the bridge payload MTU.

Recommended Action    Configure the bridge to match the interface MTU.

Error Message     
 
    
    
   

%L2-L2VPN-4-ENCAP_REMOVED_PW Pseudowire encapsulation is deleted, pseudowire attached with pw-class '[chars]' will become unresolved

Explanation    Encapsulation in the pw-class is deleted, all pseudowires attached with this pw-class will be unresolved as encapsulation type become not specified.

Recommended Action    Config the psedowire encapsulation in the pw-class and re-attach the pw-class to the pseudowires.

Error Message     
 
    
    
   

%L2-L2VPN-4-MAC_LIMIT_AC_SHUT Number of MAC addresses in AC '[chars]' has reached the configured MAC limit maximum and hence it has been shutdown

Explanation    Number of MAC addresses in the attachment circuit has reached the configured maximum. Since 'shut' action has been configured for MAC limit event on the port, it has been shut down.

Recommended Action    Manual intervention is required to bring the port up again. Please use 'clear l2vpn bridge-domain' command to bring the port up.

Error Message     
 
    
    
   

%L2-L2VPN-4-MAC_LIMIT_BD_SHUT Number of MAC addresses in bridge-domain '[chars]' has reached the configured MAC limit maximum and hence it has been shutdown

Explanation    Number of MAC addresses in the bridge-domain has reached the configured maximum. Since 'shut' action has been configured for MAC limit event on the bridge-domain, it has been shut down. All the ports under the bridge too are automatically shutdown.

Recommended Action    Manual intervention is required to bring the port up again. Please use 'clear l2vpn bridge-domain' command to bring the bridge-domain up.

Error Message     
 
    
    
   

%L2-L2VPN-4-MAC_LIMIT_PW_SHUT Number of MAC addresses in PW '[chars], [unsigned long int]' has reached the configured MAC limit maximum and hence it has been shutdown

Explanation    Number of MAC addresses in the pseudowire has reached the configured maximum. Since 'shut' action has been configured for MAC limit event on the port, it has been shut down.

Recommended Action    Manual intervention is required to bring the port up again. Please use 'clear l2vpn bridge-domain' command to bring the port up.

Error Message     
 
    
    
   

%L2-L2VPN-4-PROVISIONING_WARNING L2VPN sanity check failed for Attachment Circuit on node [chars]: [chars]. Limit is [dec]

Explanation    An internal error has been encountered and the Attachment Circuit cannot be established.

Recommended Action    Verify that the number of Attachment Circuits (AC) on the router does not exceed the L2VPN scaling capability for that line card. It may get resolved by removing the configuration for the ACs that are in UR or DN state including the ones identified in this message. Then re-configure the required ACs without exceeding the node limit.

Error Message     
 
    
    
   

%L2-L2VPN-5-NO_LICENSE L2VPN AC manager could not get a license for node [chars], [chars]

Explanation    License is required for L2VPN feature to work, but AC manager could not get a license for the node from License manager.

Recommended Action    Install license for the feature.

Error Message     
 
    
    
   

%L2-L2VPN-6-BRIDGE_MTU_MISMATCH_CLEAR [chars] mtu of [dec] now matches bridge mtu

Explanation    The interface MTU now matches the bridge payload MTU.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-ENCAP_REMOVED_PW_CLEAR Unresolved pseudowire encapsulation has been resolved for pw-class '[chars]'

Explanation    Encapsulation in the pw-class is set, all pseudowires attached to this pw-class should be out of the unresolved state.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_AC_CLEAR Number of MAC addresses in AC '[chars]' has gone below 75 percent of the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the attachment circuit has gone below 75% of the configured maximum. If MAC learning or/and unicast flooding was disabled on the port due to MAC limit action, then it would get re-enabled automatically.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_AC_SET Number of MAC addresses in AC '[chars]' has reached the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the attachment circuit has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_BD_CLEAR Number of MAC addresses in bridge-domain '[chars]' has gone below 75 percent of the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the attachment circuit has gone below 75% of the configured maximum. If MAC learning or/and unicast flooding was disabled on the bridge-domain due to MAC limit action, then it would get re-enabled automatically.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_BD_SET Number of MAC addresses in bridge-domain '[chars]' has reached the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the bridge-domain has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_PW_CLEAR Number of MAC addresses in PW '[chars], [unsigned long int]' has gone below 75 percent of the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the pseudowire has gone below 75% of the configured maximum. If MAC learning or/and unicast flooding was disabled on the port due to MAC limit action, then it would get re-enabled automatically.

Recommended Action    No particular action is required.

Error Message     
 
    
    
   

%L2-L2VPN-6-MAC_LIMIT_PW_SET Number of MAC addresses in PW '[chars], [unsigned long int]' has reached the configured MAC limit maximum, [chars]

Explanation    Number of MAC addresses in the pseudowire has reached the configured maximum. If MAC limit action to disable MAC learning and unicast flooding has been configured on the port, then that particular action might have been taken automatically.

Recommended Action    No particular action is required.

LACP_LITE Messages

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_LL_DLL_ASYNC_SEND_FAIL Send async pulse to lacp lite process fails; Error [chars]

Explanation    Attempt to send pulse to LACP lite process fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_LL_DLL_CHAN_CONNECT_FAIL Cannot connect to lacp lite process; Error [chars]

Explanation    Attempt to connect to LACP lite process channel fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_SHMEM_MMAP_FAIL Cannot mmap file [chars]; Error [chars]

Explanation    Attempt to mmap the shared memory fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_SHMEM_OPEN_FAIL Cannot open shmem file [chars]; Error [chars]

Explanation    Attempt to open the shared memory fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_SHMEM_TRNC_FAIL Cannot truncate file [chars] to [dec] bytes; Error [chars]

Explanation    Attempt to truncate the shared memory file fails

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_SHMEM_UNAVAILABLE LACP lite SHMEM can accommodate only [dec] records (request for [dec] records)

Explanation    BM-Local has requested transfer of more interface records than shared memory can accommodate

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LACP_LITE-3-ERR_UNSUPPORTED_FLAG LACP lite API is called with unsupportd flag (request for [dec])

Explanation    BM-Local has called LACP lite API with unsupported flag

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.

LC Messages

Error Message     
 
    
    
   

%L2-LC-0-TESTEMERG [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-1-TESTALERT [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-2-TESTCRIT [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-3-BMA_CHKPT Call to [chars] failed, chkpt_status equals [hex]

Explanation    The library call failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA_CHKPT_NOINIT Error initializing checkpointing table.

Explanation    The driver was not able to initialize a table to store checkpointed data.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA_CHKPT_NORESTORE The driver was not able to restore '[chars]' from checkpointed data.

Explanation    No checkpointing record was found in the table.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA_CHKPT_NOSAVE The driver was not able to save '[chars]' in checkpointed data.

Explanation    BMA buffer carve information could not be saved in the checkpoint record.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA_CHKPT_RECOVERY_NODATA The driver is coming up in RECOVERY_MODE, but the checkpoint info does not exist.

Explanation    When a driver comes up in RECOVERY_MODE, checkpointing data should have already been saved to the checkpointing record by the previous life of the driver.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA_DI_INVALID_MODE DI started the driver in an invalid mode: [hex]

Explanation    The Driver Infrastructure (DI) started the driver in an invalid or unsupported mode.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMA48ERR [chars] BMA error: stat_reg [hex] adr [hex] data [hex] qm [hex] plim [hex] l3 [hex] ms [hex] sdram [hex]

Explanation    There is an error in the BMA (reg. information).

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMA48ERRS [chars] BMA48 [chars] error [hex]

Explanation    There is an error in the BMA48.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMA48FIM [chars] BMA48 [chars] error fim_cf_status [hex]; fim_df0: adr [hex] data [hex]; fim_df1: adr [hex] data [hex]; fim_df2: adr [hex] data [hex]; fim_df3: adr [hex] data [hex]

Explanation    There is an error in the BMA.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMABUFF [chars] BMA has [unsigned int] buffers in queue [unsigned int] when maximum of [unsigned int] are allowed

Explanation    Number of buffers in one of the BMA queues has overflowed.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMACMDFTCH Problem in BMA command fetching, status equals [dec] [chars] BMA

Explanation    The BMA encountered problems while trying to fetch the given command. If appears more than once we may have a HW problem. The GRP should recognize a lost of communication with the LC and reload it.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-BMACMDLOST [chars] BMA has lost a command

Explanation    The given BMA has lost a command. If appears more than once we may have a HW problem. The GRP should recognize a lost of communication with the LC and reload it.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-BMACMDRPLY Problem in BMA reply to command type [dec] [chars] BMA sequence no equals [dec]

Explanation    There was a problem in the reply to the given BMA command. If appears more than once we may have a HW problem. The GRP should recognize a lost of communication with the LC and reload it.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAERR [chars] error: msstat [hex] dma0 [hex] dma1 [hex] dma2 [hex] qm [hex] plim [hex] fia [hex] l3 [hex] ms [hex] sdram [hex]

Explanation    There is an error in the BMA (reg. information).

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAERRS [chars] [chars] error [hex]

Explanation    There is an error in the BMA.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAERRSS [chars] [chars] error [hex] [chars] [hex]

Explanation    There is an error in the BMA.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAMEM [chars] SDRAM data error [hex] in address [hex]

Explanation    Packet memory parity error. Each bit (0-15) set in data error word represents a parity error in one byte of the errored location in memory. Bits 16 and 17 of data error word, if either is set, indicate the error happened during CPU access to the packet memory, otherwise it is during normal operation. Address represents the offset of the memory location being accessed from the beginning of packet memory on the side mentioned (to or from fabric.) This error indicates a possibly temporary problem in either the packet memory device or the BMA.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-LC-3-BMASDRAM_BADCAS_LATENCY [chars] DIMMs do not support CAS latency needed. got [hex]

Explanation    SDRAM DIMM modules installed in BMA SDRAM DIMM sockets do not support CAS latency needed. CAS latency is specified in the DIMM EEPROM as a number. When converted to a binary number, each bit corresponds to one CAS latency. Bit 2 must be set to 1, indicating that a CAS latency of 3 is supported.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMASDRAM_BADSIZE [chars] DIMMs are of unsupported size. Read this: rows [dec], cols [dec], DIMM banks [dec], SDRAM Device banks [dec]

Explanation    SDRAM DIMM modules installed in BMA SDRAM DIMM sockets are of unsupported size.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMASDRAM_BADWIDTH [chars] DIMMs have unsupported data width, expected [dec], got [dec]

Explanation    SDRAM DIMM modules installed in BMA SDRAM DIMM sockets have unsupported data width.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMASDRAM_NOTMATCH [chars] SDRAM DIMMs do not match

Explanation    SDRAM DIMM modules installed in to Fabric or from Fabric BMA DIMM0 and DIMM1 sockets do not match. While the DIMMs on one side (to Fabric) could be different from the DIMMs on the other side (from Fabric), the two DIMMs on the same side have to be identical. Also, all four DIMMs need to be mounted and making proper contact.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAUCODE_GET [chars] BMA: feature [chars], line card type [chars], could not get [chars] BMA microcode

Explanation    For the BMA microcode download command, failed to get the given BMA microcode bundled in the image.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAUCODE_LCTYPE [chars] BMA: feature [chars], specified linecard type(s) ([hex]) ! equals current ([hex])

Explanation    For the BMA microcode download command, there was a mismatch between what was specified in the BMA microcode file and the current type of line card

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-BMAUCODE_NULL Null downloaded BMA microcode

Explanation    For the BMA microcode download command, failed to get the given BMA microcode bundled in the image because it is null.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-CARVE_BUFHDRS [chars] BMA: out of SDRAM buffer headers

Explanation    Ran out of available SDRAM buffer headers while attempting to carve buffers. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-CARVE_BUFSIZE [chars] BMA: illegal specified/real SDRAM buffer size(s) equals ([unsigned long int],[unsigned long int]). Range equals ([dec],[dec])

Explanation    The calculated SDRAM buffer size (in bytes and including header and data portions), is not within the given range. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_EXBUFS [chars] BMA: [unsigned int] SDRAM buffers max ([unsigned int])

Explanation    The maximum number of SDRAM buffer headers is limited to a maximum number which has been exceeded. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_EXFREEQS [chars] BMA: [unsigned int] free queues max ([unsigned int])

Explanation    Number of free queues allowed for SDRAM buffer carving has been exceeded. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_EXPCT [chars] BMA: [unsigned int] sum SDRAM buffer percentages 100

Explanation    The sum of percentages per SDRAM buffer size has exceeded 100. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_EXSDRAM [chars] BMA: used SDRAM ([unsigned long long int] bytes) available for carve ([unsigned long int] bytes)

Explanation    The calculated sum of SDRAM to be carved is larger than the available SDRAM for carving. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_NOFREEQS [chars] BMA: no more free queues

Explanation    There are no more available free queues which can be used for SDRAM buffer carve. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_PARMS [chars] BMA: equals 1 SDRAM bufmem parameters equals equals 0

Explanation    This is an internal parameter error with one or more SDRAM buffer memory parameters: maximum buffer header count or SDRAM sizes (total, not available for carve, and available for carve

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_QELEM [chars] BMA: [unsigned int] Queue Manager SRAM elements max ([unsigned int])

Explanation    Ran out of Queue Manager elements, which are used for SDRAM buffer carving. This could be a cause of SDRAM buffer carve failure.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-CARVE_QMREAD BMA address [hex]: Queue Manager SRAM [hex], read error(s)

Explanation    This happened during Queue Manager SRAM initialization. Reading one or more zeroed Queue Manager SRAM locations gave a non-zero result. Possible errors are in head, tail, length, length threshold, buffer address, next queue element, or scratch RAM locations.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-DOWNREV BMA is an old version.

Explanation    The system software detected an old version of the BMA.

Recommended Action    Call your technical support for an upgraded verion.

Error Message     
 
    
    
   

%L2-LC-3-IICDEV_NOTACKADDR IIC Device [dec] failed to ack address

Explanation    BMA SDRAM DIMM failed to acknowledge address. This is an SDRAM IIC bus protocol error.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-IICDEV_NOTACKREAD IIC Device [dec] failed to ack read command

Explanation    BMA SDRAM DIMM failed to acknowledge read command. This is an SDRAM IIC bus protocol error.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-IICDEV_NOTRESPOND IIC Device [dec] does not respond, perhaps absent

Explanation    BMA SDRAM DIMM does not respond, perhaps absent.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-INIT_CARD_TYPE Unknown card type ([hex])

Explanation    A card was either manufactured improperly, has failed, or is newer than the software

Recommended Action    Replace the card or upgrade the software

Error Message     
 
    
    
   

%L2-LC-3-INIT_MEM Memory failure, addr [hex], read [hex]%08x, not [hex]%08x

Explanation    Initialization of the memory address failed.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-INIT_READ Error reading memory at [hex]

Explanation    Failed to read the given memory location.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-INIT_RESET Failed to take line card out of reset

Explanation    Initialization of the line card IO registers failed.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-INIT_ZERO No bytes to write to location [hex]

Explanation    No bytes were written to the given location.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-INVQ Invalid local output queue: [hex] [hex] [hex] [hex] [hex] [hex]

Explanation    The above packet was routed to an invalid queue. The data shown s the packet header.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-L3FEERR L3FE error: rxbma [hex] addr [hex] txbma [hex] addr [hex] dram [hex] addr [hex] io [hex] addr [hex]

Explanation    There was an error in the line card's L3FE ASIC (reg. information).

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-L3FEERRS L3FE [chars] error [hex] address [hex]

Explanation    There was an error in the line card's L3FE ASIC.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-LC_CODE_DLD_ALLOC Failed buffer allocation for code download

Explanation    Could not allocate a data buffer to contain contents of the given linecard downloaded file. There may be insufficient DRAM.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-LC_CODE_DLD_CHKSUM code download IPC data checksum error

Explanation    For the GLC code download command, failed the checksum verification.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-LC_CODE_PROG no downloaded code to program

Explanation    For the GLC code program command, no downloaded code to program.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-LOOKUP_ERROR Hardware assist lookup error [hex] in memory encountered

Explanation    Memory corruption detected.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-MACSTR Adj/midb ([chars]) has incorrect high word ([hex]) in its mac string

Explanation    The line card CEF/MDS received an adjacency/midb with the incorrect mac rewrite string. Packets forwarded to that adjacency/midb will be dropped.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-OUTINFO Adj/midb([chars]): incorrect output_info equals [hex] maclen equals [dec]

Explanation    The line card CEF/MDS received an adjacency/midb with the incorrect output_info field. Packets forwarded to that adjacency/midb will be dropped.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-3-PARITYERRTTM48 Parity error in memory encountered

Explanation    One bit memory corruption detected.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-SELECTOR [dec]: unknown BMA selector value

Explanation    An unknown BMA selector value was encountered.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative

Error Message     
 
    
    
   

%L2-LC-3-TESTERR [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-4-CARVE_JVMASK [chars] BMA: suspect return value [dec] on quiesce-for-carve

Explanation    The BMA quiesce-for-carve algorithm retrieved a bad jump vector mask return value. This could indicate an error in the quiesce.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-4-CARVE_TIME [chars] BMA: quiesce-for-carve exceeded timeout ([dec] ms) in [chars] loop, [dec] times

Explanation    The BMA quiesce-for-carve algorithm waits an allotted time for line card queues to flush. One or more waits exceeded this allotted time. These queues are specific to the line card's ASICs. This error message might not actually indicate an error - the allotted time might not be sufficient and should be increased.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message     
 
    
    
   

%L2-LC-4-TESTWARNING [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-5-TESTNOTICE [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-6-TESTINFO [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

Error Message     
 
    
    
   

%L2-LC-7-TESTDEBUG [chars]

Explanation    Test message for software test.

Recommended Action    Stop typing LC test logger.

MARVEL Messages

Error Message     
 
    
    
   

%L2-MARVEL-3-CHAN_CREATE Failed to create channel : [chars]

Explanation    Failed to create marvel-test (driver) channel using event_manager_create.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-DEBUG_INIT Debug initialization failed

Explanation    Initialization of the debug event failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-DEBUG_REG Debug registration failed : [chars]

Explanation    debug_register() call failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-EVENT_MGR_FAIL [chars] : [chars]

Explanation    Generic failure of any event manager API.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-MMAP Failed to map device address : [chars]

Explanation    mmap() system call failed to map the device physical address.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-MSG_REPLY Failed to send reply message : [chars]

Explanation    This error is reported when msg_reply() (LWM call) fails.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-NOMEM Failed to allocate memory

Explanation    This error is reported when malloc()/calloc() type system call fails.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-3-OPEN Failed to open file [chars] : [chars]

Explanation    This error is generated when the open() system call fails.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MARVEL-6-RX_ASYNC_MSG Invalid asynchronous message received.

Explanation    This error is generated when an invalid asynchronous message is received.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

METRO_STATS_API Messages

Error Message     
 
    
    
   

%L2-METRO_STATS_API-7-DEBUG_MSG Debug Msg : [chars]: [chars]

Explanation    This is a debug message in the Hardware Stats Manager Library to indicate anomalies. In most cases these messages will stop once the temporary condition is resolved. Examples of when this error occurs are: 1. The client connection handle received is NULL 2. The arguments to the bind message are incorrect 3. Unable to bind to the hardware IPC driver 4. Error while trying to initialize debug event. 5. Not enough memory to bind to the client

Recommended Action    No action is required. These are Debug messages. An error was returned by Stats Manager APIs to applications. Applications receiving this error will report the error.

Error Message     
 
    
    
   

%L2-METRO_STATS_API-7-ERR_DLL_INIT DLL INIT : [chars]: [chars]

Explanation    This error indicates that there was an error while initializing the stats dll.

Recommended Action    No action is required. The process is restarted automatically.

Error Message     
 
    
    
   

%L2-METRO_STATS_API-7-ERR_THREAD Locking issues: [chars]: [chars]

Explanation    This error indicates that the Hardware Stats Manager Library is unable to initialize/destroy locking for client's attributes and tables.

Recommended Action    An error was returned by Stats Manager APIs to applications. Applications receiving this error will report it. Take recommended actions specified in the application's error message. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-METRO_STATS_API-7-RESERVE_LMT_MSG Stats Counters Exhausted Msg : [chars] [dec] [chars] [dec] [chars] [chars]

Explanation    This is a debug message in the Hardware Stats Manager Library to indicate the stats reserve limit is reached. In most cases these messages will stop once the temporary condition is resolved. Examples of when this error occurs are: 1. The client tries more counters than that are free for that type

Recommended Action    No action is required. These are Debug messages. An error was returned by Stats Manager APIs to applications. Applications receiving this error will report the error.

METRO_STATS Messages

Error Message     
 
    
    
   

%L2-METRO_STATS-7-ERR_INIT [chars]: [chars]

Explanation    These errors are encountered at mstats process initialization time. The types of errors are: 1 Unable to determine hardware version. 2 Unable to create event manager. This will prevent stats process from receiving events. 3 Unable to create timer. 4 Unable to initialize client database. This will result in clients not being able to register with stats server to collect stats. 5 Unable to allocate Ingress/Egress stats. This will result in Stats manager not being able to maintain/update any hardware stats. 6 Unable to register with debug. This will prevent stats process from logging debug messages. 7 Unable to initialize or register with checkpoint service. This will prevent stats manager from restoring the information required at restart. 8 Unable to connect with SYSDB. This includes failure to connect, bind, register with SYSDB. 9 Unable to Initialize hardware packet service.

Recommended Action    No action is required. Process will be restarted. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-METRO_STATS-7-ERR_MEM Memory error: [chars]: [chars]

Explanation    An error occurred in Hardware Stats Manager during shared memory operations. This may be because the system is running low on memory. The types of errors are: 1 Cannot open/reset/close shared memory window 2 Cannot allocate/free shared memory. This will cause Stats Server to not be able to have a shadow copy of stats for all clients.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

METRO_UIDB Messages

Error Message     
 
    
    
   

%L2-METRO_UIDB-7-ERR_INIT [chars] failed due to [chars]

Explanation    Initialization of uidb_svr process has failed due to one of the following reasons: 1) Failed to create server context. 2) Failed to get schedular parameters. 3) Failed to initialize event manager. This would prevent process from receiving events. 4) Failed to register with debug. This would prevent process from logging debug messages. 5) Failed to bind UIDB server with MIPC server. This is needed to program features in hardware. 6) Failed to connect to PLIM asic processes. This is needed to program features in hardware. 7) Failed to initialize checkpoint. This is needed to checkpoint UIDB data to restore on process restart. 8) Failed to allocate, initialize and checkpoint shadow memory. This is needed to store and restore UIDB internal data. 9) Failed to get metro asic version. 10) Failed to attach event handlers needed to handle LWM messages. This is needed to enable/disable various features in hardware. 11) Various Sysdb or EDM failures 12) event_block failed. This indicates process has encountered unexpected error while waiting for events.

Recommended Action    No action is required. Process will be restarted. If not recovered, it's a fatal condition. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

MFR_EA_LTRACE_DLL Messages

Error Message     
 
    
    
   

%L2-MFR_EA_LTRACE_DLL-3-OPER_FAIL ltrace dll : [chars]

Explanation    MFR EA ltrace dll operation failure

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MFR_EA_LTRACE Messages

Error Message     
 
    
    
   

%L2-MFR_EA_LTRACE-3-ERROR_INIT_FAIL ltrace initialization operation failed for error traces: [chars]

Explanation    The MFR EA ltrace lib failed to initialize the error ltrace

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA_LTRACE-3-EVENT_INIT_FAIL ltrace initialization operation failed for events: [chars]

Explanation    The MFR EA ltrace lib failed to initialize the events ltrace

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA_LTRACE-3-INTERNAL_INIT_FAIL ltrace initialization operation failed for internal traces: [chars]

Explanation    The MFR EA ltrace lib failed to initialize the internal ltrace

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MFR_EA Messages

Error Message     
 
    
    
   

%L2-MFR_EA-2-DPC_CALL_FAILED MFR EA failed handling a DPC [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-2-INTERNAL_ERR [chars]

Explanation    Internal error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-AIB_INIT_FAILED Failed during AIB initialization, err: [chars]

Explanation    The MFR EA process initialization failed whilst trying to connect to AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-INTERFACE_OPERATION_FAILED Interface [chars] operation failed for index [dec]

Explanation    The MFR EA process failed whilst trying to change interface state.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MALLOC Memory allocation failed: [chars]

Explanation    A call to malloc failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_AIB_REMOVE_FAILED Failed during AIB remove, err: [chars]

Explanation    The MFR EA process failed whilst trying to remove entry from AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_AIB_SET_FAILED Failed during AIB set , err: [chars]

Explanation    The MFR EA process failed whilst trying to insert entry to AIB.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_CAPS_ADD_FAILED Failed during caps set, err: [chars]

Explanation    The MFR EA process failed whilst trying to set caps.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_CAPS_REMOVE_FAILED Failed during caps remove, err: [chars]

Explanation    The MFR EA process failed whilst trying to remove caps.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_ENCAP_REMOVE_FAILED Failed during encaps remove, err: [chars]

Explanation    The MFR EA process failed whilst trying to remove encaps.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_ENCAP_SET_FAILED Failed during encaps set, err: [chars]

Explanation    The MFR EA process failed whilst trying to set encaps.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-MEMBER_INFO_COLLECT_FAILED Failed to collect member link inforamtion, err: [chars]

Explanation    The MFR EA process failed whilst trying to collect member link info.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-NO_STATS Failed to initialize MFR interface stats collection, err: [chars]

Explanation    The MFR EA interface stats collection initialization failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_EA-3-STATE_CHANGE_FAILED Failed during interface state change, err: [chars]

Explanation    The MFR EA process failed whilst trying to change interface state.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MFR_MA Messages

Error Message     
 
    
    
   

%L2-MFR_MA-2-FAIL MFR MA failed to [chars]. Thread id is [dec]. [chars]

Explanation    During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-DPC_ERROR [chars] [hex] [chars]

Explanation    An error occurred during an operation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-ENCAP Unable to process mfr encapsulation request

Explanation    An error occurred processing a request to set mfr encapsulation on an interface.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-ERR_MEMBER_ADD Cannot add [chars] to bundle with nodeid [hex] and group [dec]

Explanation    Could not find the bundle interface with the nodeid and group. Hence cannot add the member interface to bundle.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-ERR_MUTEX_LOCK Mutex lock failed. [chars]

Explanation    Locking the mutex governing the access to MFR MA IDB database failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-ERR_PULSE Received unexpected Async Event [hex] for ifhandle [hex]

Explanation    IPC thread received an async event pulse for which there is no handler.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-ERROR [chars] [chars]

Explanation    An error occurred during an operation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-MALLOC Memory allocation failed: [chars]

Explanation    A call to malloc failed.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-RECVFROM An error occurred receiving a packet: [chars]

Explanation    The socket call recvfrom returned an error.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-3-THREAD_ERROR [chars] . Thread id is [dec]. [chars]

Explanation    An error occurred during an operation.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_CHKPT Unexpected error encountered whilst [chars]: [chars]

Explanation    MFR MA encountered an error using the Checkpoint Service. The error message describes what operation has failed and why it failed. The most likely reason for this a low memory condition but the error could also be caused by a programming error.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_CHKPT_CORRUPT Corrupt [chars] checkpoint record found: [chars]

Explanation    Whilst restoring one of its checkpoint tables MFR MA found a corrupt checkpoint entry. The entry will be ignored and so the relevant interface's MFR session will be renegotiated after the restart and as a result there may be a short period where traffic is lost.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_CHKPT_DUPLICATE Duplicate [chars] checkpoint record found for [chars]

Explanation    Whilst restoring one of its checkpoint tables MFR MA found multiple entries for the same interface. MFR MA will use the first checkpoint entry it finds for each interface and ignore any subsequent duplicates. This is caused by a programming error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information..

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_EVC_ERROR Error resetting '[chars]' connection: [chars]

Explanation    After detecting an error with the connection to the specified service, MFR MA failed to reset that connection. This is an internal error. It requires a restart of the process for recovery.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_MEM_ALLOC Failed to allocate [unsigned int] bytes for '[chars]'

Explanation    The process failed to allocate memory for the specified resource.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_MGD_TIMER Unexpected error encountered whilst [chars]: [chars]

Explanation    MFR MA encountered an unexpected error using the Managed Timer library. This is most likely due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. Consider restarting the MFR MA process. *RECUR*.

Error Message     
 
    
    
   

%L2-MFR_MA-4-ERR_THREAD_CREATE Failed to create '[chars]' thread: [chars]

Explanation    MFR MA encountered an unexpected error creating a new thread. The process will restart to attempt to recover. This is possibly due to a low memory condition but may also be an internal programming error. The error message should provide more information about the cause.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.. *RECUR*.

Error Message     
 
    
    
   

%L2-MFR_MA-6-SENDTO Packet send attempt timed out: [chars]

Explanation    The socket call to send a control packet timed out.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MICKEY Messages

Error Message     
 
    
    
   

%L2-MICKEY-2-INTR Mickey Intr: [chars]: [dec]: [dec]

Explanation    A high severity error has interrupted the Mickey FPGA. This might result in the PLIM being reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MICKEY-3-SERDES_CTRL Mickey Serdes Ctrl: [chars]: [dec]: [dec]: [dec]

Explanation    This message indicates that the software tried to configure an unsupported loopback type.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MICKEY-5-UNKNOWN_INTR Mickey Intr: [chars]: [dec]: [dec]

Explanation    This message indicates the Mickey FPGA has detected an unknown interrupt.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MLCTRLR Messages

Error Message     
 
    
    
   

%L2-MLCTRLR-2-NOMEM [chars]([dec]): not enough memory for [chars]

Explanation    The process is out of memory.

Recommended Action    Check process list for source of memory loss. Check if h/w memory requirements are met.

Error Message     
 
    
    
   

%L2-MLCTRLR-3-ERROR [chars]([dec]): [chars] failed ([chars]) - [chars]

Explanation    A general failure occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.

Recommended Action    Verify continued correct operation of MLCTRLR.

Error Message     
 
    
    
   

%L2-MLCTRLR-4-ALARM [chars]: [chars] [chars]

Explanation    The specified MLCTRLR Alarm has been declared or released.

Recommended Action    Recommended action is to repair the source of the alarm.

Error Message     
 
    
    
   

%L2-MLCTRLR-4-FEAC [chars] [chars]

Explanation    New Far End Alarm Code received.

Recommended Action    None.

Error Message     
 
    
    
   

%L2-MLCTRLR-4-LOOPSTATUS [chars] [chars]

Explanation    A configurable controller loopback status.

Recommended Action    None.

Error Message     
 
    
    
   

%L2-MLCTRLR-4-UPDOWN [chars]: [chars] [chars]

Explanation    The specified MLCTRLR is operationally down due to alarm. Check alarm status using show controller Mlt command on the cli.

Recommended Action    Recommended action is to repair the source of the alarm.

Error Message     
 
    
    
   

%L2-MLCTRLR-4-WARNING [chars]([dec]): [chars] - [chars]

Explanation    A non-fatal error occured while executing the function in question. The message contains info about the location and cause of the failure and possibly anticipated actions/effects.

Recommended Action    Verify continued correct operation of MLCTRLR.

MMSMLIB Messages

Error Message     
 
    
    
   

%L2-MMSMLIB-4-EXIT_ON_ERR [chars]. Reason: [chars]

Explanation    An error occurred in the PSE ASIC client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information from the PSE driver. The root cause may be located in either hardware or software.

Recommended Action    *RECUR*

MOTHRA Messages

Error Message     
 
    
    
   

%L2-MOTHRA-3-FATAL_ERROR Fatal error: [chars]: [chars]: [hex]

Explanation    A fatal error occurred in mothra Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MOTHRA-3-PIO_FATAL_ERROR Asic PIO failure : [chars], instance [dec]: rc [dec] cerr [chars] errno [dec] data1 [hex] data2 [hex]

Explanation    A fatal error occurred in Santa Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MOTHRA-6-INFO_MSG Info: [chars]: [chars]

Explanation    This is a Informational message in the mothra driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-MOTHRA-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the mothra driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MOUSE Messages

Error Message     
 
    
    
   

%L2-MOUSE-2-INTR Mouse Intr: [chars]: [dec]: [dec]

Explanation    A high severity error has interrupted the Mouse FPGA. This might result in the PLIM being reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MOUSE-5-UNKNOWN_INTR Mouse Intr: [chars]: [dec]: [dec]

Explanation    This message indicates the Mouse FPGA has detected an unknown interrupt.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

MULTILINK_UV Messages

Error Message     
 
    
    
   

%L2-MULTILINK_UV-3-ERR_MISCONFIG Misconfiguration: Item [chars] on interface [chars] is incompatible with other configuration. The system may now be in an inconsistant state.

Explanation    The Multilink Uberverifier has detected a misconfiguration. It was not detected in the verification phase, so the Uberverifier cannot correct this.

Recommended Action    The misconfiguration can be corrected by deleting all configuration from the specified interface and its subinterfaces, and then reapplying the configuration. If the problem persists, do the following: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MULTILINK_UV-3-EVENT Unrecoverable error in event loop. Error: [chars]

Explanation    An error (other than EINTR) occured in the event loop. The process must exit.

Recommended Action    Identify the location of the card where there error was reported. Copy the error message exactly as it appears on the console or in the system log. Issue the show memory location location summary command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show memory location location summary output, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MULTILINK_UV-3-INIT Failure during initialization of [chars]. Error: [chars]

Explanation    A failure occurred during the initialization of the process. This resulted in the restart of the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-MULTILINK_UV-3-SYSMGR Failure communicating readiness to System Manager. Error: [chars]

Explanation    The process was initialized successfully but was unable to inform System Manager of the success.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Multilink Messages

Error Message     
 
    
    
   

%L2-Multilink-3-INCORRECT_BW_UPDATE Bundle [chars] with bandwidth [dec]. Link ifh [hex] with bandwidth [dec]

Explanation    When the indicated member link was deactivated, bundle bandwidth could not be updated correctly as decrementing the link's bandwidth would have made the bundle bandwidth to go below zero. Bundle bandwidth is now made zero.

Recommended Action    Check the bundle and member interface status. Verify that the bundle bandwidth is correct now. If not, shut all the members of the bundle and then no shut all the members to bring back the bundle bandwidth to correct value.

Error Message     
 
    
    
   

%L2-Multilink-3-ML_GROUP_FAILURE Failed to add/remove serial link [chars] into multilink bundle [chars]

Explanation    The link addition/removal from a Multilink bundle has failed due to a software error.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-Multilink-3-MTU_IMPOSE_FAILED Failed to set MTU of [unsigned int] on [chars]

Explanation    The specified MTU could not be applied on this interface.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-Multilink-4-ALARM [chars]: [chars] [chars]

Explanation    The specified Multilink Alarm has been declared or released.

Recommended Action    Recommended action is to repair the source of the alarm.

ND Messages

Error Message     
 
    
    
   

%L2-ND-3-INIT Process initialisation failed. [chars]: [chars] ([hex])

Explanation    There was a software error during process startup.

Recommended Action    The process will restart and try to recover. If this message is not seen again and no other adverse effects are observed then there is no need to take any action. Otherwise, check whether the error code contained in the message indicates that there was a failure to allocate the necessary memory and take the following action. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If resource allocation was not the problem and it hasn't been fixed by a subsequent restart, then take the following action. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. If the process does not restart automatically, restart it manually. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

OAMMIB Messages

Error Message     
 
    
    
   

%L2-OAMMIB-3-NO_DEBUG Unable to register for OAM MIB debug. No further debugging will occur: [chars]

Explanation    In the initialisation of the OAM MIB DLL an error occurred whilst attempting to register for debugging. Consequently there will be no debug output from the OAM MIB DLL.

Recommended Action    Continue working with the OAM MIB DLL without any debugging taking place or restart the DLL such that during initialisation there is another attempt register for debugging.

Error Message     
 
    
    
   

%L2-OAMMIB-3-NO_TRAP Unable to register for SNMP traps. Traps will not be sent regardless of trap events occurring: [chars]

Explanation    In the initialisation of the OAM MIB DLL an error occurred whilst trying to register a callback function for the enabling of SNMP traps. Alternatively whilst trying to enable traps there was a failure in binding to SysDB for trap notifications.

Recommended Action    Continue working with the OAM MIB DLL without any the ability to send traps when events occur or restart the DLL such that there is another attempt to register for traps.

OC768_FRAMER_ASIC Messages

Error Message     
 
    
    
   

%L2-OC768_FRAMER_ASIC-3-CRITICAL_ERROR [chars]: [chars]: [hex]

Explanation    OC768 Framer ASIC Driver encountered a critical error which causes the process to exit.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-OC768_FRAMER_ASIC-6-INFO [chars]: [chars]

Explanation    This is a informational message from OC768 Framer ASIC driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-OC768_FRAMER_ASIC-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in OC768 Framer ASIC driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

OPTICS Messages

Error Message     
 
    
    
   

%L2-OPTICS-3-CRITICAL_ERROR Optical init failure: [chars]: [chars]: [hex]

Explanation    A critical error occurred in OPTICS Driver which involves exiting the process.

Recommended Action    Power cycle the plim.

Error Message     
 
    
    
   

%L2-OPTICS-6-INFO Info: [chars]: [chars]

Explanation    This is an informational message in the OPTICS driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-OPTICS-7-DEBUG_MSG Debug: [chars]: [chars] value [dec]

Explanation    This is a debug message in the optics driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PAL_CGM Messages

Error Message     
 
    
    
   

%L2-PAL_CGM-3-INIT_ERROR Initialization failed: ([chars]%s)

Explanation    The PAL ACL CGM DLL failed to initialize because of memory alloc failure. This DLL does a generalization of an Access Control List to include matching on MQC match criteria If the ccl DLL fails to initialize, the access control list cannot be programmed into the hardware.

Recommended Action    The failure should be handled by the process that is loading the DLL. The calling process should retry the initialization.

PFILTER_EA Messages

Error Message     
 
    
    
   

%L2-PFILTER_EA-3-ERR_IM_CAPS [chars] acl failed on interface CH[hex]. [chars]

Explanation    1) An ACL could not be applied to hardware because of one of the following reasons: a) TCAM max limit has been reached. b) RLB resources are not available. c) IPv6 address compression table is full. This error can happen when a new bundle member is added and the ACL can not be programmed successfully. 2) An ACL could not be removed from hardware.

Recommended Action    1) When this error occurs the running-config will not be in sync with line card configuration. It is recommended that the bundle member on which the error occured be removed from the bundle. The ACL configuration may also be reduced until it can be successfully programmed on the new bundle member. 2) If the ACL could not be removed from hardware a line card reload is recommended.

Error Message     
 
    
    
   

%L2-PFILTER_EA-3-ERR_IM_CAPS [chars] acl failed on interface CH[hex]. [chars]

Explanation    1) An ACL could not be applied to hardware because of one of the following reasons: a) TCAM max limit has been reached. b) RLB resources are not available. c) IPv6 address compression table is full. This error can happen when a new bundle member is added and the ACL can not be programmed successfully. 2) An ACL could not be removed from hardware.

Recommended Action    1) When this error occurs the running-config will not be in sync with line card configuration. It is recommended that the bundle member on which the error occured be removed from the bundle. The ACL configuration may also be reduced until it can be successfully programmed on the new bundle member. 2) If the ACL could not be removed from hardware a line card reload is recommended.

Error Message     
 
    
    
   

%L2-PFILTER_EA-3-INIT_ERROR Process initialization failed: ([chars]%s)

Explanation    The pfilter_ea process failed to initialize. This pfilter_ea process programs the 'packet filter' security access control list in the hardware. If the pfilter_ea process fails to initialize, the access control list cannot be programmed into the hardware. %s - indicates the reason for the initialization failure. %s - is the decoded error reason.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process pfilter_ea location 0/x/cpu0' to verify that the process is up and running. If it is still non-operational, try doing 'process restart pfilter_ea location 0/x/cpu0'. Collect all debug information if the process is continually restarting 'debug pfilter-ea all' (during the process restart). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PFILTER_EA-3-INIT_ERROR Process initialization failed: ([chars]%s)

Explanation    The pfilter_ea process failed to initialize. This pfilter_ea process programs the 'packet filter' security access control list in the hardware. If the pfilter_ea process fails to initialize, the access control list cannot be programmed into the hardware. %s - indicates the reason for the initialization failure. %s - is the decoded error reason.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process pfilter_ea location 0/x/cpu0' to verify that the process is up and running. If it is still non-operational, try doing 'process restart pfilter_ea location 0/x/cpu0'. Collect all debug information if the process is continually restarting 'debug pfilter-ea all' (during the process restart). If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PFILTER_EA-7-EVENT_ERROR Event Failure: ([chars])

Explanation    The pfilter_ea process received a bad event. This pfilter_ea process programs the 'packet filter' security access control list in the hardware. %s - is the decoded error reason.

Recommended Action    Monitor the event messages. The pfilter_ea process will handle the failure gracefully but if they continually appear on the console, try doing 'process restart pfilter_ea location 0/x/cpu0'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PFILTER_EA-7-EVENT_ERROR Event Failure: ([chars])

Explanation    The pfilter_ea process received a bad event. This pfilter_ea process programs the 'packet filter' security access control list in the hardware. %s - is the decoded error reason.

Recommended Action    Monitor the event messages. The pfilter_ea process will handle the failure gracefully but if they continually appear on the console, try doing 'process restart pfilter_ea location 0/x/cpu0'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PFILTER_EA-7-INIT [chars] failed due to [chars]

Explanation    Initialization of packet filter process has failed due to one of the following reasons: 1) Failed to initialize event manager. This would prevent process from receiving events. 2) Failed to register with debug. This would prevent process from logging debug messages. 3) Failure to connect with SYSDB. 4) Failed initialize internal permit/deny entries for IPv4/IPv6. These entries are needed for programming/removal of hardware entries for IPv4/IPv6 security ACLs. 5) Failed to initialize connection with interface manager proxy service. 6) Failed to initialize RLB (range logic block) checkpoint. This is needed for checkpointing range logic block information for restore on process restart. 7) Failed to initialize Feature EA DLL API needed for programming of hardware resources. 8) Failed to initialize callback function from Feature EA DLL for compiling IPv4/IPv6 TCAM entries needed for security ACL programming in hardeare. 9) Failed to initialize callback function from Feature EA DLL to handle reprogramming of RLB and IPv6 source prefix compression table request from TCAM manager. 10) Failed to initialize feature checkpoint info. This is needed for checkpointing IPv4 and IPv6 security ACLs programmed in hardware. 11) Failed to initialize callback functions from ACL configuration manager to perform hardware resource checks and ACE resequencing. 12) event_block failed. This indicates process has encountered unexpected error while waiting for events. 13) Failed to initialize callback functions for receiving incremental updates for IPv4/IPv6 security ACL configuration.

Recommended Action    No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

Error Message     
 
    
    
   

%L2-PFILTER_EA-7-INIT [chars] failed due to [chars]

Explanation    Initialization of packet filter process has failed due to one of the following reasons: 1) Failed to initialize event manager. This would prevent process from receiving events. 2) Failed to register with debug. This would prevent process from logging debug messages. 3) Failure to connect with SYSDB. 4) Failed initialize internal permit/deny entries for IPv4/IPv6. These entries are needed for programming/removal of hardware entries for IPv4/IPv6 security ACLs. 5) Failed to initialize connection with interface manager proxy service. 6) Failed to initialize RLB (range logic block) checkpoint. This is needed for checkpointing range logic block information for restore on process restart. 7) Failed to initialize Feature EA DLL API needed for programming of hardware resources. 8) Failed to initialize callback function from Feature EA DLL for compiling IPv4/IPv6 TCAM entries needed for security ACL programming in hardeare. 9) Failed to initialize callback function from Feature EA DLL to handle reprogramming of RLB and IPv6 source prefix compression table request from TCAM manager. 10) Failed to initialize feature checkpoint info. This is needed for checkpointing IPv4 and IPv6 security ACLs programmed in hardware. 11) Failed to initialize callback functions from ACL configuration manager to perform hardware resource checks and ACE resequencing. 12) event_block failed. This indicates process has encountered unexpected error while waiting for events. 13) Failed to initialize callback functions for receiving incremental updates for IPv4/IPv6 security ACL configuration.

Recommended Action    No action is required. Process will be restarted. If not recovered, it's a fatal condition. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information. *REDUCE*

PLAOC768_API Messages

Error Message     
 
    
    
   

%L2-PLAOC768_API-3-CRITICAL_ERROR [chars]: [chars]: [hex]

Explanation    PLAOC768 system checkout Library encountered a critical error which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLAOC768_API-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message from the PLAOC768 system checkout Library to indicate either anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temporary situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLAOC768 Messages

Error Message     
 
    
    
   

%L2-PLAOC768-3-ASIC_ERROR [chars] : block [dec] error [dec], [chars]

Explanation    An ASIC error occurred in PLAOC768 ASIC which is reported here.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLAOC768-3-CRITICAL_ERROR [chars]: [chars]: [dec]

Explanation    PLAOC768 Driver encountered an critical error condition which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLAOC768-3-PIO_CRITICAL_ERROR Asic PIO failure : [chars], instance [dec]: rc [dec] cerr [chars] errno [dec] data1 [hex] data2 [hex]

Explanation    A critical error occurred in PLAOC768 Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLAOC768-6-INFO [chars]: [chars]

Explanation    This is a informational message in the PLAOC768 driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-PLAOC768-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message from the PLAOC768 driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLATFORM_ATM_OAM Messages

Error Message     
 
    
    
   

%L2-PLATFORM_ATM_OAM-3-PACKET_RX ATM OAM PKT RX error:[chars]

Explanation    There was a software error while processing received OAM cell

Recommended Action    No action required if the message is displayed just a few times and stops after that. If the message repeats continously, collect the System Messages displayed on the console and provide them to cisco support. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

plim_4p_oc12 Messages

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-ALLOC_FAILED Process failed to allocate memory [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized due to unavailable memory and will be restarted. It may affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller,...

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-CREATE_THREAD_ERROR Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller,... %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-DEBUG_INIT_ERROR Debugging subsystem initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize it's debug subsystem. As result plim debug commands will not work on the PLIM module in question. The rest of functionality of the PLIM driver remains unaffected by the failure. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    Restart the process using 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0'. Process restart may affect traffic on all 4 oc12 interfaces located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-ERR_EVM_CREATE Interface module driver initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of such failure no trafiic may pass on all 4 oc12 ports located on the 4 port linecard. The interfaces associated with failed PLIM will not come up.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt to restart the process using command 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-ERR_EVM_EVENT_BLOCK process received invalid event [chars]

Explanation    Physical Layer Interface Module(PLIM) driver experience an errorr while awaiting for event arrival. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of the error the PLIM process will be restarted. Traffic may be interrupted on all affected interfaces. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0 If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-ERR_PORT_INIT PLIM port init failed [dec] stage-[chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize port. As result of the failure affected interfaces will not come up. %d - failed port number %s - specific stage of port initialization that failed PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer and Packet Over Sonet(POS) controller.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-FWD_REGISTER_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller,... %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-PORT_AVAILABLE_FAILED Port failed to become available [chars] [dec]

Explanation    Physical Layer Interface Module(PLIM) driver failed to make port available for forwarding. The interface in question will not forward packets. %s - error code %d - port number

Recommended Action    Restart the process using 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0'. Process restart may affect traffic on all 4 oc12 interfaces located on the line card. Reload the line card using 'hw-module location 0/slot/cpu0 reload' if the process restart failed to solve the problem.. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-RESET_FAILED PLIM reset failed [chars]

Explanation    The Physical Layer Interface Module(PLIM) driver failed to reset PLIM hardware. %s - error code PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist consider restarting plim process ( 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0'. PLIM process restart may affect traffic on all 4 oc12 ports. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-STATS_COLLECT_REGISTER_FAILED Statistics collector registration error [chars] [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to register PLIM interface statistics collector. No interface statistics such as sonet counters and packet counters will be available on the specified interface. %s - contains interface name %s - contains error code

Recommended Action    Restart the process using 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0'. Process restart may affect traffic on all 4 oc12 interfaces located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-STATSD_COLL_INIT_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller,... %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-TIMER_INIT_FAILED Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller,... %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_4p_oc12 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_4p_oc12 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-TX_CLK_GET_INVALID_PORT_CTX Failed to retrieve tx clock source

Explanation    Physical Layer Interface Module(PLIM) driver was unable to determine transmit clock source for the sonet port. The error may appear during show or configuration of the sonet port.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist contact technical support.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-3-TX_CLK_SET_INVALID_PORT_CTX Failed to configure tx clock source for sonet port

Explanation    Physical Layer Interface Module(PLIM) driver failed to make configure transmit clock source for the sonet port. The sonet port hardware configuration is invalid and may result in traffic being dropped or high error count on the port. This error may appear during attempt to configure clock source for the sonet port.

Recommended Action    Retry the sonet port configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_4p_oc12-4-INVALID_TIMER Invalid timer [dec]

Explanation    Physical Layer Interface Module(PLIM) driver received unknown timer event. %d - timer type

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLIM_4P_OC192 Messages

Error Message     
 
    
    
   

%L2-PLIM_4P_OC192-3-DEVICE_INTR_CLEAR No Framer/RAC devices are generating excessive interrupts

Explanation    The previously reported excessive interrupts condition has been cleared. Interrupt rate limiting has been disabled.

Recommended Action    none

Error Message     
 
    
    
   

%L2-PLIM_4P_OC192-3-DEVICE_INTR_DISABLE Excessive interrupts from the [chars] device of port [hex]

Explanation    The specified device is generating excessive interrupts. This message indicates that we are rate limiting the interrupt coming from this device. This indicates a potential HW issue, traffic forwarding (protection switching) may be impacted.

Recommended Action    Check the fiber or the peer connection. If the problem persist after checking fiber and peer router, please contact support.

Error Message     
 
    
    
   

%L2-PLIM_4P_OC192-3-ERR [chars]

Explanation    fail to init debug service event manager fails to provide its service

Recommended Action    sysmgr will respawn plim_4p_oc192 'show logging' to look for the errors from event manager

Error Message     
 
    
    
   

%L2-PLIM_4P_OC192-3-MEM_ERR [chars]

Explanation    fail to allocate memory.

Recommended Action    sysmgr would restart the process. show process memory to find out whehter there is potential memory leak show memory to confirm system memory goes low

PLIM_ASIC_API Messages

Error Message     
 
    
    
   

%L2-PLIM_ASIC_API-7-ERR [chars] Reason:[chars]

Explanation    BAMBI API generated errors.

Recommended Action    No action is required.

PLIM_ASIC Messages

Error Message     
 
    
    
   

%L2-PLIM_ASIC-2-EIO_TRAIN PLASPA: [chars]

Explanation    EIO training errors. The EIO link to the PLASPA failed to train. This will result in traffic loss through this PLIM.

Recommended Action    Check seating of both the PLIM and the MSC and then reload the MSC. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_ASIC-3-ERR [chars]

Explanation    Plim asic driver errors. Typically these errors indicate failure in system services or bad programming of the hardware.

Recommended Action    Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_ASIC-3-HW_ERR plaspa instance [dec] [chars], [chars]

Explanation    Plim Asic errors. Typically these indicate errors detected by the ASIC. Too many of these errors might indicate problem with the board, and can trigger a reload of the LC.

Recommended Action    Check whether process 'plaspa_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_ASIC-3-LTRACE_INIT Ltrace init for file [chars] failed [chars]

Explanation    --

Recommended Action    Typcially these indicate that ltrace is out of service. check at other processes using ltrace and see whether the problem happens to them.

PLIM_CLKSEL Messages

Error Message     
 
    
    
   

%L2-PLIM_CLKSEL-3-ERR_INIT PLIM process is restarted because of a failure in Clock Selection Library initialization: ([chars]/[chars]).

Explanation    The initilaization of the Clock Selection Library failed. The Clock Selection Library is used by the physical layer interface module (PLIM) driver on the linecard. The PLIM driver creates the SONET controller and POS interface, handling the all the SONET event, applying SONET/POS configuration to the layer-1 device hardware. If the PLIM driver fails to initialize, no traffic will pass, therefore no higher level protocol will work. %s - indicates the reason for the failure %s - is the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn the PLIM process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process process name location 0/x/cpu0' to verify that the process is up and running, where process name equals 'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48 linecard; If it is still non-operational, try to do a manually process restart with CLI: 'process restart process name location 0/x/cpu0'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_CLKSEL-4-ERR_DEBUG Debug initialization failed with [chars].

Explanation    Debug message initialzation failed.

Recommended Action    This error has no effect on any feature except that debug information cannot be turned on by CLI 'debug plim-clksel location 0/x/CPU0'. Restarting the process with the CLI below, process restart will not affect traffic. 'process restart process name location 0/x/CPU0' may resolve the problem.

PLIM_FPGA Messages

Error Message     
 
    
    
   

%L2-PLIM_FPGA-3-CRITICAL_ERROR [chars]: [chars]: [hex]

Explanation    PLIM FPGA ASIC Driver encountered a critical error as described in the error message. This error causes PLIM OC768 process to exit.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_FPGA-3-PIO_CRITICAL_ERROR Asic PIO failure : [chars], instance [dec]: rc [dec] cerr [chars] errno [dec] data1 [hex] data2 [hex]

Explanation    A critical error occurred in PLIM FPGA Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_FPGA-6-INFO [chars]: [chars]

Explanation    This is a informational message from PLIM FPGA driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-PLIM_FPGA-7-DEBUG_MSG Debug: [chars]: [chars] value [dec]

Explanation    This is a debug message in PLIM FPGA driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLIM_IOX_4P_GE Messages

Error Message     
 
    
    
   

%L2-PLIM_IOX_4P_GE-3-INIT_ERR Initialization error: [chars]: [chars]

Explanation    The 4 port Gigabit Ethernet (GE) driver failed to initialize properly. This driver provides the system access to the hardware. A failure during initialization of this process may render the interfaces provided by the hardware unusable. %s - indicates the reason for the failure %s - is the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process, up to a fixed number of times when this error is encountered, to recover. Execute 'show process plim_iox_4p_ge location 0/x/cpu0' to verify that the process is up and running. If it is still non-operational, try doing 'process restart plim_iox_4p_ge location 0/x/cpu0' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_IOX_4P_GE-6-INFO_MSG [chars] [dec]

Explanation    This is an Informational message in the plim_iox_4p_ge driver to indicate operation that may be of interest to the user.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-PLIM_IOX_4P_GE-6-RXLOS_INT SFP Rx LOS Interrupt: port: [dec], count equals [dec]

Explanation    This is an informational message in the gigE driver driver to indicate a Loss of Signal (LOS) has occurred on the indicated port.

Recommended Action    1. Ensure the equipment at the far end of the link is functioning and configurations are correct. 2. Ensure the cable are installed correctly Rx plugged into far-end Tx & Tx plugged into far-end Rx 3. Check SFP and cable compatability. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLIM_LIB Messages

Error Message     
 
    
    
   

%L2-PLIM_LIB-2-ERR_FM_REPLY Physical layer interface module library failed to reply to the Fault Manager for error recovery: [chars]

Explanation    The PLIM driver soft error recovery failed because the PLIM library function failed with replying to the Fault Manager request. If the PLIM soft error recovery failed, the PLIM hardware state may not be in the correct state, and the traffic may be affected. %s - is the decoded error reason

Recommended Action    The Fault Manager will reset the linecard if the error recovery failed, search through the event logs, if there is no any message indicating that the Fault Manager has reset the linecard, try to do a manually reset with CLI: 'hw-module location 0/x/cpu0 reload' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_LIB-2-ERR_FM_REQUEST The Fault Manager cannot send message to physical layer interface module driver to start soft error recovery: [chars]/[chars]

Explanation    When a soft error is detected with any ASIC on the datapath, the Fault Manager will start the soft error recovery on the datapath. If the Fault Manager cannot send request to the PLIM driver, the soft error recovery will not be completed, therefore the traffic will not go through the datapath. %s - indicates the reason for the failure %s - is the decoded error reason

Recommended Action    The Fault Manager will reset the linecard if sending message failed, search through the event logs, if there is no any message indicating that the Fault Manager has reset the linecard, try to do a manually reset with CLI: 'hw-module location 0/x/cpu0 reload' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_LIB-3-ERR_INIT Physical layer interface module library initialization failed: ([chars]/[chars]).

Explanation    The physical layer interface module (PLIM) library on the linecard failed to initialize. The PLIM library is used by PLIM driver which creates the SONET controller, POS interface, handling the all the SONET event and applying SONET/POS configuration to the layer1 devices. If the PLIM driver failed to initialize, no traffic will pass, therefore no higher level protocol will work. %s - indicates the reason for the failure %s - is the decoded error reason

Recommended Action    The System Manager process (sysmgr) will automatically respawn the PLIM process, up to a fixed number of times when this error is encountered, to recover. Execute the following command to verify that the process is up and running. 'show process process name location 0/x/cpu0' where process name equals 'e48_plim_oc3' for OC3 linecard; 'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48 linecard; If it is still non-operational, try to do a manually process restart with CLI: 'process restart process name location 0/x/cpu0'. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_LIB-3-ERROR error: [chars]: [chars]: [hex]

Explanation    A fatal error occurred in the plim library driver which involves exiting the process.

Recommended Action    collect the info from 'show diag', 'show hfr', 'show inv' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_LIB-4-ERR_MSG_RCV Physical layer interface module library failed in receiving the message: [chars]

Explanation    The PLIM library detects a failure condition when receiving the message. The message is used only for error recovery, the process should not receive the message in normal case. This error means a error condition is detected while the process is waiting for a message, it can be ignored if the error does not persist. Otherwise, if the error persists, it is recommended to restart the process, restarting process will not affect the traffic.

Recommended Action    If the error persists, execute the following command to restart the process. 'process restart process name location 0/x/cpu0' where process name equals 'e48_plim_oc3' for OC3 linecard; 'pl_e48_pos_4p_oc12' for OC12 linecard; 'pl_e48_pos_1p_oc48' for OC48 linecard; If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_LIB-7-DEBUG [chars]: [chars] errno [dec]

Explanation    This is a debug message in the PLIM library driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    'show logging' to confirm sysdb errors

plim_oc48 Messages

Error Message     
 
    
    
   

%L2-plim_oc48-3-ALLOC_FAILED Process failed to allocate memory [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized due to unavailable memory and will be restarted. It may affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver.

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ALLOC_FAILED Process failed to allocate memory [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized due to unavailable memory and will be restarted. It may affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver.

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-CREATE_THREAD_ERROR Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-CREATE_THREAD_ERROR Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-DEBUG_INIT_ERROR Debugging subsystem initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize it's debug subsystem. As result plim debug commands will not work on the PLIM module in question. The rest of functionality of the PLIM driver remains unaffected by the failure. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-DEBUG_INIT_ERROR Debugging subsystem initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize it's debug subsystem. As result plim debug commands will not work on the PLIM module in question. The rest of functionality of the PLIM driver remains unaffected by the failure. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-E3_BW_CHNG_REJ DSU bandwidth change for E3 controller is not supported

Explanation    This is a known hardware limitation. The bandwidth will be defaulted to 34010 kbps.

Recommended Action    None.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_EVM_CREATE Interface module driver initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of such failure no trafiic may pass on the oc48 port located on the linecard. The interfaces associated with failed PLIM will not come up.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt to restart the process using command 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_EVM_CREATE Interface module driver initialization failed

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of such failure no trafiic may pass on the oc48 port located on the linecard. The interfaces associated with failed PLIM will not come up.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt to restart the process using command 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_EVM_EVENT_BLOCK process received invalid event [chars]

Explanation    Physical Layer Interface Module(PLIM) driver experience an errorr while awaiting for event arrival. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of the error the PLIM process will be restarted. Traffic may be interrupted on all affected interfaces. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0 If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_EVM_EVENT_BLOCK process received invalid event [chars]

Explanation    Physical Layer Interface Module(PLIM) driver experience an errorr while awaiting for event arrival. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller. As result of the error the PLIM process will be restarted. Traffic may be interrupted on all affected interfaces. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered to recover. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If it's not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0 If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_MBUS_OP Optical parameter measurement error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to measure laser bias or optical receive power. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. PLIM driver performs periodic measurements of the laser bias and received signal optical power. The results of such measurements are represented in the 'show controller pos 0/slot/0/0' command under the 'optical power monitoring' section. %s - error code

Recommended Action    If the error persist reset the linecard using 'hw-module location 0/slot/CPU0 reload' command. The line card restart may affect traffic passing on the oc48 interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_MBUS_OP Optical parameter measurement error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to measure laser bias or optical receive power. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. PLIM driver performs periodic measurements of the laser bias and received signal optical power. The results of such measurements are represented in the 'show controller pos 0/slot/0/0' command under the 'optical power monitoring' section. %s - error code

Recommended Action    If the error persist reset the linecard using 'hw-module location 0/slot/CPU0 reload' command. The line card restart may affect traffic passing on the oc48 interface. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_PORT_INIT PLIM port init failed [dec] stage-[chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize port. As result of the failure affected interfaces will not come up. %d - failed port number %s - specific stage of port initialization that failed PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer and Packet Over Sonet(POS) controller.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-ERR_PORT_INIT PLIM port init failed [dec] stage-[chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize port. As result of the failure affected interfaces will not come up. %d - failed port number %s - specific stage of port initialization that failed PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer and Packet Over Sonet(POS) controller.

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-FWD_REGISTER_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-FWD_REGISTER_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-PORT_AVAILABLE_FAILED Port failed to become available [chars] [dec]

Explanation    Physical Layer Interface Module(PLIM) driver failed to make port available for forwarding. The interface in question will not forward packets. %s - error code %d - port number

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. Reload the line card using 'hw-module location 0/slot/cpu0 reload' if the process restart failed to solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-PORT_AVAILABLE_FAILED Port failed to become available [chars] [dec]

Explanation    Physical Layer Interface Module(PLIM) driver failed to make port available for forwarding. The interface in question will not forward packets. %s - error code %d - port number

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. Reload the line card using 'hw-module location 0/slot/cpu0 reload' if the process restart failed to solve the problem. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-RESET_FAILED PLIM reset failed [chars]

Explanation    The Physical Layer Interface Module(PLIM) driver failed to reset PLIM hardware. %s - error code PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist consider restarting plim process ( 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. PLIM process restart may affect traffic on the oc48 port located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-RESET_FAILED PLIM reset failed [chars]

Explanation    The Physical Layer Interface Module(PLIM) driver failed to reset PLIM hardware. %s - error code PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist consider restarting plim process ( 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. PLIM process restart may affect traffic on the oc48 port located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-STATS_COLLECT_REGISTER_FAILED Statistics collector registration error [chars] [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to register PLIM interface statistics collector. No interface statistics such as sonet counters and packet counters will be available on the specified interface. %s - contains interface name %s - contains error code

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-STATS_COLLECT_REGISTER_FAILED Statistics collector registration error [chars] [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to register PLIM interface statistics collector. No interface statistics such as sonet counters and packet counters will be available on the specified interface. %s - contains interface name %s - contains error code

Recommended Action    Restart the process using 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0'. Process restart may affect traffic on the oc48 interface located on the line card. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-STATSD_COLL_INIT_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-STATSD_COLL_INIT_ERROR Process initialization error [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialized and will be restarted. It will affect traffic passing through the ports located on the PLIM. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically restart this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TIMER_INIT_FAILED Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TIMER_INIT_FAILED Process init failed [chars]

Explanation    Physical Layer Interface Module(PLIM) driver failed to initialize. PLIM driver is responsible for initializing/configuring PLIM hardware such as sonet framer, Packet Over Sonet(POS) controller, optical transceiver. %s - error code

Recommended Action    The System Manager process (sysmgr) will automatically respawn this process up to a fixed number of times when this error is encountered. Execute 'show process pl_e48_pos_1p_oc48 location 0/slot/cpu0' to verify that the process is up and running. If the process is not operational attempt 'process restart pl_e48_pos_1p_oc48 location 0/slot/cpu0' where slot - is slot number in question. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TX_CLK_GET_INVALID_PORT_CTX Failed to retrieve tx clock source

Explanation    Physical Layer Interface Module(PLIM) driver was unable to determine transmit clock source for the sonet port. The error may appear during show or configuration of the sonet port.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist contact technical support.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TX_CLK_GET_INVALID_PORT_CTX Failed to retrieve tx clock source

Explanation    Physical Layer Interface Module(PLIM) driver was unable to determine transmit clock source for the sonet port. The error may appear during show or configuration of the sonet port.

Recommended Action    If the error occurred during user command execution retry the command and if the error persist contact technical support.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TX_CLK_SET_INVALID_PORT_CTX Failed to configure tx clock source for sonet port

Explanation    Physical Layer Interface Module(PLIM) driver failed to make configure transmit clock source for the sonet port. The sonet port hardware configuration is invalid and may result in traffic being dropped or high error count on the port. This error may appear during attempt to configure clock source for the sonet port.

Recommended Action    Retry the sonet port configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-3-TX_CLK_SET_INVALID_PORT_CTX Failed to configure tx clock source for sonet port

Explanation    Physical Layer Interface Module(PLIM) driver failed to make configure transmit clock source for the sonet port. The sonet port hardware configuration is invalid and may result in traffic being dropped or high error count on the port. This error may appear during attempt to configure clock source for the sonet port.

Recommended Action    Retry the sonet port configuration. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-4-INVALID_TIMER Invalid timer [dec]

Explanation    Physical Layer Interface Module(PLIM) driver received unknown timer event. %d - timer type

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-plim_oc48-4-INVALID_TIMER Invalid timer [dec]

Explanation    Physical Layer Interface Module(PLIM) driver received unknown timer event. %d - timer type

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLIM_OC768 Messages

Error Message     
 
    
    
   

%L2-PLIM_OC768-3-CRITICAL_ERROR [chars]: [chars]: [hex]

Explanation    PLIM OC768 driver encountered a critical error as described in the error message. This error causes PLIM OC768 process to exit.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM_OC768-6-INFO [chars]: [chars]

Explanation    This is an informational message from PLIM OC768 driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-PLIM_OC768-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the plim_oc768 driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PLIM Messages

Error Message     
 
    
    
   

%L2-PLIM-2-EIO_TRAIN PLA: [chars], [chars]

Explanation    EIO training errors. The PLA EIO failed to train... this will result in traffic loss and the MSC will fail to send traffic thru the PLIM.

Recommended Action    Currently, the only recovery is for an MSC reload. Once the Fault-Mgr is available, the ASIC will be reset in order to retrain the EIO. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM-3-CHK_ERR PLA: [chars], [chars]

Explanation    Checkpoint Initialization Failure. The pla_server process failed to initialize its checkpointing data. The process cannot continue and needs to be restarted.

Recommended Action    None, the process should recover. If it does not, the system will most likely be in an unrecoverable state and will take appropriate action. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM-3-ERR [chars]

Explanation    fail to init debug events; sysdb fails to provide services; event mgr fails to provides its services;

Recommended Action    pla_server would be restarted by sysmgr. check out whether there is any problems with sysdb check out whether there is any problems with the event mgr there should be error msgs from sysdb or event msg. 'show logging' could confirm this sh plim pla trace info sh plim pla trace error

Error Message     
 
    
    
   

%L2-PLIM-3-HW_ERR asic error: [chars]

Explanation    Plim Asic errors. Typically these indicate errors detected by the ASIC. Too many of these errors might indicate problem with the board, and can trigger a reload of the LC.

Recommended Action    Check whether process 'pla_server' is up and running. Check if the linecard reported any other errors and/or traffic loss was observed. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PLIM-3-INCONSISTENT_CONFIG [chars]

Explanation    As part of trying to configure dot1q vlan with vlan id same as that of outer vlan of QinQ configuration or vice versa on another sub-interface, then error has to be reported to remove the inconsistent config.

Recommended Action    Upon seeing this message, delete the subinterface that has just been created. Otherwise the system will be in inconsistent state.

Error Message     
 
    
    
   

%L2-PLIM-3-MEM_ERR [chars]

Explanation    fail to allocate memory.

Recommended Action    show process memory to find out whehter there is potential memory leak show memory to confirm system memory goes low sh plim pla trace info sh plim pla trace error

Error Message     
 
    
    
   

%L2-PLIM-3-SQUID_ERR [chars]

Explanation    squid fails to find the device

Recommended Action    1. reseat the plim. 2. if the problem is still there after reseating, run diag on the plim

pm5315 Messages

Error Message     
 
    
    
   

%L2-pm5315-3-FATAL_ERROR Fatal error: [chars]: [chars]: [dec]

Explanation    A fatal error occurred in karachi Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-pm5315-6-INFO_MSG Info: [chars]: [chars]

Explanation    This is a Informational message in the karachi driver to indicate an operation.

Recommended Action    No action is required.

Error Message     
 
    
    
   

%L2-pm5315-7-DEBUG_MSG Debug: [chars]: [chars] errno [dec]

Explanation    This is a debug message in the karachi driver to indicate anomolies which are not FATAL. Some of the messages may indicate a failure to allocate resources needed by applications. In many cases these messages must not keep appearing after the temperory situation is resolved.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

pm5316 Messages

Error Message     
 
    
    
   

%L2-pm5316-3-FATAL_ERROR [chars](): fatal error: [chars]: [chars]: [dec]

Explanation    A fatal error occurred in plim Driver which involves exiting the process.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-pm5316-4-WARNING [chars](): warning: [chars]: [chars]: [dec]

Explanation    A warning condition occurred in plim Driver which involves exiting the process.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

PM622 Messages

Error Message     
 
    
    
   

%L2-PM622-2-error [chars]

Explanation    A high severity error has occurred in PLIM FPGA. This might result in the PLIM being reset.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

PMSAR Messages

Error Message     
 
    
    
   

%L2-PMSAR-2-CFG_ERR : [chars]: [dec]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CHAN_STATS_ERR [chars]() [dec], chan:[dec],[dec],[dec]; cid:[dec], sar:[dec] reason:[chars] status:[dec], ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CLOSE_VC_COSQ_ERR [chars]() [dec], close cosq failure. rsar:[dec], ssar:[dec], queue:[dec], cosq_id:[dec] reason:[chars]; status:[dec] ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CLOSE_VC_ERR [chars]() [dec], close vc failure. rsar:[dec], ssar:[dec], vpi:[dec], vci:[dec] reason:[chars]; status:[dec] ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CMD_ACK_ERR [chars]() [dec], SAR:[dec] poll incomplete cmd ack, [chars]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CMD_ERR [chars]

Explanation    A critical PM622 TSP command failed that expected to succeed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CMD_POLL_TIMEOUT [chars]() [dec], SAR:[dec] cmd poll timed out, [chars]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-CMD_POST_ERR [chars]() [dec], SAR:[dec] post cmd failure. status:[dec], [chars] [dec] ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-INITERR Fatal error: [chars]: [hex]

Explanation    SAR device cx27470 initialization failed

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-MMAPERR [chars](),[dec]: [chars] [hex]

Explanation    SAR device cx27470 mmap access violation failure

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-MUTEX_TIMEOUT [chars]() [dec], Get SAR:[dec], thread_id:[dec] mutex timed out, [chars]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-OPEN_VC_ERR [chars]() [dec], open vc failure. rsar:[dec], ssar:[dec], vpi:[dec], vci:[dec] reason:[chars]; status:[dec], ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-OPEN_VP_ERR [chars]() [dec], open vp failure. sar:[dec] vpi:[dec], reason:[chars]; ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-PORT_STATS_ERR [chars]() [dec], port stats failure. sar:[dec] reason:[chars]; status:[dec], ack:[hex], [hex], [hex], [hex]

Explanation    A fatal error occurred during PM SAR Driver cofiguration

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-2-RESOURCE_ERR [chars] [dec], [chars] with errno:[dec]

Explanation    A critical IOX resource request failed that expected to succeed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-3-ESYS_ERR [chars] [dec]: reason [chars] errno:[dec]

Explanation    CX27470 esys generic fatal error message.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-3-ESYS_LOAD_ELF [chars] [dec]: file [chars] [chars] [chars]

Explanation    CX27470 esys load elf input file symbol not found.

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-3-EVENT_INDICATE [chars]() [dec], reason:[chars]; sar:[dec], log_entry_index:[dec], type:[dec], status:[dec]

Explanation    An event raised PM SAR Driver, check the event type

Recommended Action    If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%L2-PMSAR-3-UNKNOWN_EVENT [chars]() [dec], reason:[chars]; sar:[dec], log_entry_index:[dec]