Cisco IOS XR System Error Reference Guide for XR1200 Series Platform Specific Messages, Release 3.3
Fabric Messages
Downloads: This chapterpdf (PDF - 149.0KB) The complete bookPDF (PDF - 2.03MB) | Feedback

Fabric Messages

Table Of Contents

Fabric Messages

FABQ Messages


Fabric Messages


This section contains all Fabric (hardware and software both) related System Error Messages. The following facility codes are represented in this module:

FABQ Messages

FABQ Messages

Error Message     
 
    
    
   

%FABRIC-FABQ-3-FATAL FABQ: fatal error encountered, reason=[chars]

Explanation    Fabric Queue Driver encountered a fatal error and is not able recover from the error. A reason text will be supplied. Call support with this text.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-INIT_ERROR Process initialization failed: ([chars]%s)

Explanation    PRP fabric queue process failed to initialize. The fabric queue process handles fabric connectivity. It initializes and starts up the threads in ToFab and FrFab components. An unrecoverable failure of the process may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_ERROR Packet carving failed to initialize: ([chars]%s)

Explanation    Initial carving of a packet particle pool failed. Platform specific memory region, packet header and particle pool configuration information are required by the generic packet manager process (PAKMAN) to operate. A failure in packet carving initialization may prevent this route processor from communicating with other cards in the chassis. %s - indicates the reason for the failure. %s - is the error reason.

Recommended Action    If a redundant route processor card has been configured: 1 - force a failover with the following command in admin mode: 'redundancy switchover' 2 - reload the route processor card that failed with the following command in admin mode: 'reload location RP/0/x/CPU0' where x is the slot of route processor that generated the error. If no redundant RP is configured, you will need to reboot the router by issuing the reload command. If the error recurs call your Cisco technical support representative and provide the gathered information. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_FAIL PKT_INIT: [chars] failed, rc=[dec], reason:[chars]

Explanation    Packet carving function has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-PKT_INIT_POOL PKT_INIT: particle_multi_pool_define failed ([chars]), rc=[dec], reason:[chars]

Explanation    Initial carving of a packet particle pool has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-3-SHOW_ERR FABQ_SHOW: fatal error encountered: [chars]

Explanation    Error while executing a show command

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.

Error Message     
 
    
    
   

%FABRIC-FABQ-6-PKT_INIT_INFO PKT_INIT: pak mem size:[hex], pak mem start: [hex], pak scaling:[dec]

Explanation    Information on packet memory carving

Recommended Action    This is information and does not require any correction.

Error Message     
 
    
    
   

%FABRIC-FABQ-7-PKT_INIT_INFO Packet initialization: pak mem size:[hex], pak mem start: [hex], pak scaling:[dec]

Explanation    Information on packet memory carving.

Recommended Action    This is informational and does not require any correction.