This documentation has been moved.
PPPoE Circuit-Id Tag Processing
Downloads: This chapterpdf (PDF - 201.0KB) The complete bookPDF (PDF - 2.22MB) | Feedback

PPPoE Circuit-Id Tag Processing

Table Of Contents

PPPoE Circuit-Id Tag Processing

Finding Feature Information

Contents

Prerequisites for the PPPoE Circuit-Id Tag Processing Feature

Information About the PPPoE Circuit-Id Tag Processing Feature

Differences Between ATM- and Fast or Gigabit Ethernet-Based Broadband Access Networks

DSL Forum 2004-71 Solution

Approach for a Circuit-Id Tag in Ethernet-Based Broadband Access Networks

Benefits of the PPPoE Circuit-Id Tag Processing Feature

How to Configure the PPPoE Circuit-Id Tag Processing Feature

Configuring the PPPoE Circuit-Id Tag Processing Feature

Removing the PPPoE Circuit-Id Tag

Displaying the Session Activity Log

Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature

Configuring PPPoE Circuit-Id Tag Processing: Example

Configuring BRAS to Include a NAS-Port-Id Attribute: Example

Removing the PPPoE Circuit-Id Tag: Example

Additional References

Related Documents

Standards

MIBs

RFCs

Technical Assistance

Feature Information for PPPoE Circuit-Id Tag Processing


PPPoE Circuit-Id Tag Processing


First Published: February 14, 2006
Last Updated: May 4, 2009

The PPPoE Circuit-Id Tag Processing feature provides a way to extract a Circuit-Id tag from the digital subscriber line (DSL) as an identifier for the authentication, authorization, and accounting (AAA) access request on a Fast Ethernet or Gigabit Ethernet interface, thereby simulating ATM-based Broadband access, but using cost-effective Fast Ethernet or Gigabit Ethernet instead. The tag is useful for troubleshooting the network, and is also used in RADIUS authentication and accounting processes.

Finding Feature Information

For the latest feature information and caveats, see the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the "Feature Information for PPPoE Circuit-Id Tag Processing" section.

Use Cisco Feature Navigator to find information about platform support and Cisco IOS XE software image support. To access Cisco Feature Navigator, go to http://www.cisco.com/go/cfn. An account on Cisco.com is not required.

Contents

Prerequisites for the PPPoE Circuit-Id Tag Processing Feature

Information About the PPPoE Circuit-Id Tag Processing Feature

How to Configure the PPPoE Circuit-Id Tag Processing Feature

Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature

Additional References

Prerequisites for the PPPoE Circuit-Id Tag Processing Feature

It is recommended that you be familiar with RFC 2516 before configuring this feature. See the "RFCs" section for a pointer to this standard.

Information About the PPPoE Circuit-Id Tag Processing Feature

To configure the PPPoE Circuit-Id Tag Processing feature, you should understand the following concepts:

Differences Between ATM- and Fast or Gigabit Ethernet-Based Broadband Access Networks

DSL Forum 2004-71 Solution

Approach for a Circuit-Id Tag in Ethernet-Based Broadband Access Networks

Benefits of the PPPoE Circuit-Id Tag Processing Feature

Differences Between ATM- and Fast or Gigabit Ethernet-Based Broadband Access Networks

Broadband digital subscriber line multiplexer (DSLAM) and Broadband Remote Access Server (BRAS) vendors see a need to provide Fast or Gigabit Ethernet-based networks as an alternative to an ATM access network, with a DSLAM bridging the ATM-DSL local loop to the Fast or Gigabit Ethernet-based access network and allowing Fast or Gigabit Ethernet-based connectivity to the BRAS. But in an Fast or Gigabit Ethernet access network, there is no unique mapping between the subscriber Line-Id and the interface, as is found in an ATM-based network. In an ATM-based network, the ATM VC is associated to a subscriber line.

During the authentication phase that initiates the PPP access and AAA accounting requests, the BRAS includes a NAS-Port-Id attribute in RADIUS authentication packets, if the feature "TAL based on the NAS-Port-Id" feature is configured. This attribute identifies the DSL line for the subscriber. See "Configuring BRAS to Include a NAS-Port-Id Attribute: Example" section for an example.

DSL Forum 2004-71 Solution

To apply the same subscriber mapping capability to Fast or Gigabit Ethernet interfaces that is possible on ATM interfaces, DSL Forum 2004-71 proposes a solution whereby the DSLAM sends the DSL Line-Id in the PPP over Ethernet (PPPoE) discovery phase. This method provides a way for a PPPoE server acting as a BRAS to extract the Line-Id tag and use the Circuit-Id field of that tag as a NAS-Port-Id attribute in AAA access and accounting requests. The PPPoE Circuit-Id Tag Processing feature makes use of the proposed DSL Forum 2004-71 method and allows the BRAS to detect the presence of the subscriber Circuit-Id tag inserted by the DSLAM during the PPPoE discovery phase. The BRAS will send this tag as a NAS-Port-Id attribute in PPP authentication and AAA accounting requests. The tag is useful in troubleshooting the Ethernet network, and it is also used in RADIUS authentication and accounting processes.

Approach for a Circuit-Id Tag in Ethernet-Based Broadband Access Networks

Traditional ATM-based DSL broadband access networks have the topology shown in Figure 1.

Figure 1 ATM-Based DSL Broadband Access Network

In terms of logical connectivity, there is a one-to-one mapping of the DSL subscriber line to the end user and the ATM VC used to carry the PPP session through the DSLAM and to the BRAS, where this VC information is converted into a NAS-Port-Id for use in RADIUS packets.

The simple mapping available from an ATM-based network between the physical line in the DSL local loop to the end user and a VC (from DSLAM to BRAS) is not available for an Fast or Gigabit Ethernet-based network. To solve this problem, the PPPoE Circuit-Id Tag Processing feature uses a PPPoE intermediate agent function on the DSLAM to attach a tag to the PPPoE discovery packets. The BRAS then receives the tagged packet, decodes the tag, and inserts the line identifier into RADIUS packets destined for the RADIUS server.

DSLAM intercepts PPPoE discovery frames from the client and inserts a unique line identifier (circuit-id) using the PPPoE Vendor-Specific tag (0x0105) to PPPoE Active Discovery Initiation and Request (PADI and PADR) packets; see Figure 2. The DSLAM forwards these packets to the BRAS after the insertion. The tag contains the circuit-id of the DSL line on which the PADI or PADR packet was received, in the access node where the intermediate agent resides.

Figure 2 PPPoE Circuit-Id Tag Processing Solution

When the vendor-tag circuit-id service command is configured in BBA (broadband access) group configuration mode, the BRAS processes the received PPPoE Vendor-Specific tag in the PADR packet and extracts the Circuit-Id field, which is sent to the remote AAA server as the NAS-Port-Id attribute (RADIUS attribute 87) in RADIUS access and accounting requests. When the radius-server attribute nas-port format d global configuration command is also configured on the BRAS, the Acct-Session-Id attribute will contain the information about the incoming access interface, where discovery frames are received, and about the session being established.

Outgoing PAD Offer and Session-confirmation (PADO and PADS) packets from the BRAS will have the DSLAM-inserted Circuit-Id tag. DSLAM should strip the tag out of PADO and PADS packets. If the DSLAM cannot strip off the tag, the BRAS should remove it before sending the packets out, and this is accomplished using the vendor-tag circuit-id strip BBA group configuration mode command.

Benefits of the PPPoE Circuit-Id Tag Processing Feature

The shift towards Fast or Gigabit Ethernet-based DSLAMs offers the following benefits:

Ability to use simpler and lower cost provisioning options for DSL subscribers over an Fast or Gigabit Ethernet-based backhaul network rather than on an ATM-based network.

Ability to use higher bandwidth connectivity options available from Fast or Gigabit Ethernet not possible on ATM.

Ability to upgrade to next-generation DSLAMs with quality of service (QoS), and support for higher bandwidth, asymmetric dual latency modems such as the ADSL2.

Ability to inject high-bandwidth content such as video in an Ethernet network.

How to Configure the PPPoE Circuit-Id Tag Processing Feature

This section contains the following procedures:

Configuring the PPPoE Circuit-Id Tag Processing Feature (Required)

Removing the PPPoE Circuit-Id Tag (Required)

Displaying the Session Activity Log (Optional)

Configuring the PPPoE Circuit-Id Tag Processing Feature

This section describes how to configure an Fast or Gigabit Ethernet-based access network on a Cisco BRAS. The extracted Circuit-Id tag (see "Information About the PPPoE Circuit-Id Tag Processing Feature" section) is sent in the following RADIUS syntax, as recommended by the DSL Forum:

"Access-Node-Identifier eth slot/port[:vlan-tag]"

The Access-Node-Identifier is a unique subscriber identifier or telephone number text string entered without spaces. Per DSL-Forum 2004-71, the maximum length supported for the tag is 48 bytes. The BRAS copies the entire tag into the NAS-Port-Id and sends it to the AAA server.

SUMMARY STEPS

1. enable

2. configure terminal

3. radius-server attribute nas-port format d

4. bba-group pppoe group-name

5. vendor-tag circuit-id service

DETAILED STEPS

 
Command or Action
Purpose

Step 1 

enable

Example:

Router> enable

Enables privileged EXEC mode.

Enter your password if prompted.

Step 2 

configure terminal

Example:

Router# configure terminal

Enters global configuration mode.

Step 3 

radius-server attribute nas-port format d

Example:

Router(config)# radius-server attribute nas-port format d

(Optional) Selects the PPPoE extended NAS-Port format used for RADIUS access and accounting.

Configure this command so that the Acct-Session-Id attribute, as displayed in the debug radius command, will contain the information about the incoming access interface, where discovery frames are received, and about the session being established. See the "Displaying the Session Activity Log" and "Configuring PPPoE Circuit-Id Tag Processing: Example" sections for more information.

Step 4 

bba-group pppoe group-name

Example:

Router(config-bba-group)# bba-group pppoe pppoe-group

Defines a PPPoE profile.

Step 5 

vendor-tag circuit-id service

Example:

Router(config-bba-group)# vendor-tag circuit-id service

Enables processing of the received PPPoE Vendor-Specific tag in the PADR packet, which extracts the Circuit-Id part of the tag and sends it to the AAA server as the NAS-Port-Id attribute in RADIUS access and accounting requests.

Removing the PPPoE Circuit-Id Tag

Outgoing PADO and PADS packets will have the DSLAM-inserted Vendor-Specific Line-Id tag, and DSLAM must strip the Circuit-Id tag from the packets. If the DSLAM cannot strip the tag, the BRAS must remove it before sending out the packets. This task is accomplished through configuration of the vendor-tag circuit-id strip command in BBA group configuration mode.

SUMMARY STEPS

1. enable

2. configure terminal

3. bba-group pppoe group-name

4. vendor-tag strip

DETAILED STEPS

 
Command or Action
Purpose

Step 1 

enable

Example:

Router> enable

Enables privileged EXEC mode.

Enter your password if prompted.

Step 2 

configure terminal

Example:

Router# configure terminal

Enters global configuration mode.

Step 3 

bba-group pppoe group-name

Example:

Router(config)# bba-group pppoe pppoe-group

Defines a PPPoE profile and enters BBA group configuration mode.

Step 4 

vendor-tag strip

Example:

Router(config-bba-group)# vendor-tag strip

Enables the BRAS to strip off incoming Vendor-Specific Circuit-Id tags from outgoing PADO and PADS packets.

Displaying the Session Activity Log

When the radius-server attribute nas-port format d global configuration command is added to the PPPoE Circuit-Id Tag Processing feature configuration on the BRAS (see the "Configuring PPPoE Circuit-Id Tag Processing: Example" section for an example), the report from the debug radius privileged EXEC command will include information about the incoming access interface, where discovery frames are received, and about the session being established in PPPoE extended NAS-Port format (format d).

Enable the debug radius command to display a report of session activity. In the example shown in this section:

The acct_session_id is 79 or 4F in hexadecimal format.

In the message "Acct-session-id pre-pended with Nas Port = 0/0/0/200," the interface on which the PPPoE discovery frames arrived is FastEthernet0/0.200. The 0/0/0 is Cisco format for slot/subslot/port.

The Acct-Session-Id vendor-specific attribute 44 contains the string "0/0/0/200_0000004F," which is a combination of the ingress interface and the session identifier.


Note Strings of interest in the debug radius output log are presented in bold text for example purposes only.


Router# debug radius

02:10:49: RADIUS(0000003F): Config NAS IP: 0.0.0.0
02:10:49: RADIUS/ENCODE(0000003F): acct_session_id: 79
02:10:49: RADIUS(0000003F): sending
02:10:49: RADIUS/ENCODE: Best Local IP-Address 10.0.58.141 for Radius-Server 
172.20.164.143
02:10:49: RADIUS(0000003F): Send Access-Request to 172.20.164.143:1645 id 1645/65, len 98
02:10:49: RADIUS:  authenticator 1C 9E B0 A2 82 51 C1 79 - FE 24 F4 D1 2F 84 F5 79
02:10:49: RADIUS:  Framed-Protocol     [7]   6 PPP                       [1]
02:10:49: RADIUS:  User-Name           [1]   7   "peer1"
02:10:49: RADIUS:  CHAP-Password       [3]   19  *
02:10:49: RADIUS:  NAS-Port-Type       [61]  6 Ethernet                  [15]
02:10:49: RADIUS:  NAS-Port            [5]   6   200
02:10:49: RADIUS:  NAS-Port-Id         [87]  22  "FastEthernet6/0.200:"
02:10:49: RADIUS:  Service-Type        [6]   6 Framed                    [2]
02:10:49: RADIUS:  NAS-IP-Address      [4]   6   10.0.58.141
02:10:49: RADIUS: Received from id 1645/65 172.20.164.143:1645, Access-Accept, len 32 
02:10:49: RADIUS:  authenticator 06 45 84 1B 27 1F A5 C3 - C3 C9 69 6E B9 C0 6F 94
02:10:49: RADIUS:  Service-Type        [6]   6 Framed                    [2]
02:10:49: RADIUS:  Framed-Protocol     [7]   6 PPP                       [1]
02:10:49: RADIUS(0000003F): Received from id 1645/65
02:10:49: [62]PPPoE 65: State LCP_NEGOTIATION    Event PPP_LOCAL
02:10:49: PPPoE 65/SB: Sent vtemplate request on base Vi2
02:10:49: [62]PPPoE 65: State VACCESS_REQUESTED    Event VA_RESP
02:10:49: [62]PPPoE 65: Vi2.1 interface obtained
02:10:49: [62]PPPoE 65: State PTA_BINDING    Event STAT_BIND
02:10:49: [62]PPPoE 65: data path set to Virtual Acess
02:10:49: [62]PPPoE 65: Connected PTA
02:10:49: [62]PPPoE 65: AAA get dynamic attrs
02:10:49: [62]PPPoE 65: AAA get dynamic attrs
02:10:49: RADIUS/ENCODE(0000003F):Orig. component type = PPoE
02:10:49: RADIUS/ENCODE(0000003F): Acct-session-id pre-pended with Nas Port = 0/0/0/200
02:10:49: RADIUS(0000003F): Config NAS IP: 0.0.0.0
02:10:49: RADIUS(0000003F): sending
02:10:49: RADIUS/ENCODE: Best Local IP-Address 10.0.58.141 for Radius-Server 
172.20.164.143
02:10:49: RADIUS(0000003F): Send Accounting-Request to 172.20.164.143:1646 id 1 646/42, 
len 117
02:10:49: RADIUS:  authenticator 57 24 38 1A A3 09 62 42 - 55 2F 41 71 38 E1 CC 24
02:10:49: RADIUS:  Acct-Session-Id     [44]  20  "0/0/0/200_0000004F"
02:10:49: RADIUS:  Framed-Protocol     [7]   6 PPP                       [1]
02:10:49: RADIUS:  User-Name           [1]   7   "peer1"
02:10:49: RADIUS:  Acct-Authentic      [45]  6 RADIUS                    [1]
02:10:49: RADIUS:  Acct-Status-Type    [40]  6 Start                     [1]
02:10:49: RADIUS:  NAS-Port-Type       [61]  6 Ethernet                  [15]
02:10:49: RADIUS:  NAS-Port            [5]   6   200
02:10:49: RADIUS:  NAS-Port-Id         [87]  22  "FastEthernet6/0.200:"
02:10:49: RADIUS:  Service-Type        [6]   6 Framed                    [2]
02:10:49: RADIUS:  NAS-IP-Address      [4]   6   10.0.58.141
02:10:49: RADIUS:  Acct-Delay-Time     [41]  6   0
02:10:49: RADIUS: Received from id 1646/42 172.20.164.143:1646, Accounting-resp onse, len 
20
02:10:49: RADIUS:  authenticator 34 84 7E B2 F4 40 B2 7C - C5 B2 4E 98 78 03 8B C0

Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature

This section contains the following examples:

Configuring PPPoE Circuit-Id Tag Processing: Example

Configuring BRAS to Include a NAS-Port-Id Attribute: Example

Removing the PPPoE Circuit-Id Tag: Example

Configuring PPPoE Circuit-Id Tag Processing: Example

In the following example, outgoing PADO and PADS packets will retain the incoming Vendor-Specific Circuit-Id tag:

radius-server attribute nas-port format d
!
bba-group pppoe pppoe-group
 sessions per-mac limit 50
 vendor-tag circuit-id service
!
interface FastEthernet0/0.1
 encapsulation dot1Q 120
 pppoe enable group pppoe-group

Configuring BRAS to Include a NAS-Port-Id Attribute: Example

In the following example, the feature TAL based on the NAS-Port-Id is configured. This configuration ensures that a NAS-Port-Id attribute is included in RADIUS authentication packets during the authentication phase to initiate PPP access and AAA accounting requests.

radius-server attribute nas-port
policy-map type control test
 class type control always event session-start
 1 authorize identifier nas-port

Removing the PPPoE Circuit-Id Tag: Example

In the following example, the BRAS will strip off incoming Vendor-Specific Circuit-Id tags from outgoing PADO and PADS packets:

bba-group pppoe pppoe-rm-tag
 sessions per-mac limit 50
 vendor-tag circuit-id service
 vendor-tag strip 

interface FastEthernet0/0.1
 encapsulation dot1Q 120
 pppoe enable group pppoe-group

Additional References

The following sections provide references related to the PPPoE Circuit-Id Tag Processing feature.

Related Documents

Related Topic
Document Title

Configuring Broadband and DSL

Cisco IOS XE Broadband Access Aggregation and DSL Configuration Guide

RADIUS attributes

Cisco IOS XE Security Configuration Guide

DSL Forum Line-Id tag solution

Broadband Forum


Standards

Standard
Title

None


MIBs

MIB
MIBs Link

None

To locate and download MIBs for selected platforms, Cisco IOS XE software releases, and feature sets, use Cisco MIB Locator found at the following URL:

http://www.cisco.com/go/mibs


RFCs


Technical Assistance

Description
Link

The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies.

To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds.

Access to most tools on the Cisco Support website requires a Cisco.com user ID and password.

http://www.cisco.com/techsupport


Feature Information for PPPoE Circuit-Id Tag Processing

Table 1 lists the release history for this feature.

Use Cisco Feature Navigator to find information about platform support and software image support. Cisco Feature Navigator enables you to determine which Cisco IOS XE software images support a specific software release, feature set, or platform. To access Cisco Feature Navigator, go to http://www.cisco.com/go/cfn. An account on Cisco.com is not required.


Note Table 1 lists only the Cisco IOS XE software release that introduced support for a given feature in a given Cisco IOS XE software release train. Unless noted otherwise, subsequent releases of that Cisco IOS XE software release train also support that feature.


Table 1 Feature Information for PPPoE Circuit-Id Tag Processing 

Feature Name
Releases
Feature Information

PPPoE Circuit-Id Tag Processing

Cisco IOS XE Release 2.1.

The PPPoE Circuit-Id Tag Processing feature provides a way to extract a Circuit-Id tag from the DSL as an identifier for the AAA access request on an Ethernet interface, thereby simulating ATM-based broadband access, but using cost-effective Ethernet instead. The tag is useful for troubleshooting the network, and is also used in RADIUS authentication and accounting processes.

This feature was introduced on Cisco ASR 1000 Series Aggregation Services Routers.

This feature was integrated into Cisco IOS XE
Release 2.3.1.

The following commands were introduced or modified: vendor-tag circuit-id service, vendor-tag strip.