Guest

Cisco ONS 15454 Series Multiservice Provisioning Platforms

ONS 15454 SDH MSPP Hardware and Software Compatibility Matrix

Document ID: 60599

Updated: Nov 18, 2004

   Print

Introduction

This document provides a hardware and software compatibility matrix for the Cisco ONS 15454.

Prerequisites

Requirements

Cisco recommends that you have knowledge of these topics:

  • Cisco Transport Manager (CTM)

  • Cisco Transport Controller (CTC)

  • Sun Java Runtime Environment (JRE)

Components Used

The information in this document is based on these software and hardware versions:

  • CTC version 3.30.0x through 4.6.0x

  • CTM version 3.1.x through 4.7

  • JRE version 1.3.1_01 and 1.4.2

The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.

Conventions

Refer to Cisco Technical Tips Conventions for more information on document conventions.

Hardware and Software Compatibility

ONS 15454 SDH Software Release/Hardware Compatibility: XC-VXL-2.5G Configurations

This table shows ONS 15454 Synchronous Digital Hierarchy (SDH) software and hardware compatibility for systems configured with XC-VXL-2.5G cards for Releases 3.4, 4.0, 4.1, 4.6, 5.0, 6.0 and 7.0.

Hardware 3.40.0x (3.4) 4.0.0x (4.0) 4.1.0x (4.1) 4.6.0x (4.6) 5.0.0x (5.0) 6.0.0x (6.0) 7.0.0x (7.0)
XC-VXL-2.5G Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
TCC2 Not Supported TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required
TCC2P Not Supported TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required TCC2 or TCC2P Required
AIC-I Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
E1N-14 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17
E1-42 Not Supported Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17
E3-12 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17
DS3i-N-12 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17 Supported in Slots 1–5, 13–17
STM1E-12 Not Supported Not Supported Not Supported Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17
E100T-G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
E1000-2-G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
G1000-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Not Supported Not Supported
G1K-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
ML100T-12 Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
ML-100X-8 Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
ML1000-2 Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC3 IR 4/STM1SH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC3IR/STM1SH 1310-8 Not Supported Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17
OC12 IR/STM4 SH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 LR/STM4 LH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 LR/STM4 LH 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 IR/STM4 SH 1310-4 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17 Supported in Slots 1–4, 14–17
OC48 IR/STM16 SH AS 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC48 LR/STM16 LH AS 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC48 ELR/STM16 EH 100 GHz Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13
OC192 SR/STM64 IO 1310 Not Supported Not Supported Not Supported Not Supported Not Supported Not Supported
OC192 IR/STM64 SH 1550 Not Supported Not Supported Not Supported Not Supported Not Supported Not Supported
OC192 LR/STM64 LH 1550 Not Supported Not Supported Not Supported Not Supported Not Supported Not Supported
OC192 LR/STM64 LH ITU 15xx.xx Not Supported Not Supported Not Supported Not Supported Not Supported Not Supported
OC192SR1/STM64 IO Short Reach, OC192/STM64 Any Reach1 Not Supported Not Supported Not Supported Not Supported Not Supported Not Supported
MRC-12 Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
FC_MR-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible

1 These cards are designated as STM64-XFP in CTC.

ONS 15454 SDH Software Release/Hardware Compatibility: XC10G and XC-VXL-10G Configurations

The table in this section shows ONS 15454 SDH software and hardware compatibility for systems configured with XC10G and XC-VXL-10G cards for Releases 3.4, 4.0, 4.1, 4.6, 5.0, 6.0 and 7.0. Release 4.5 is not supported on the XC10G and XC-VXL-10G cards.

Hardware 3.40.0x (3.4) 4.0.0x (4.0) 4.1.0x (4.1) 4.6.0x (4.6)      
XC-VXL-10G Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
XC-VXC-10G Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
XC10G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Not Supported Not Supported
TCC2/TCC2P Not Supported Required Required Required Required Required
AIC-I Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
E1N-14 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17
E1-42 Not Supported Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17
E3-12 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17
DS3i-N-12 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17 Fully Compatible, Slots 1–5, 13–17
STM1E-12 Not Supported Not Supported Not Supported Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17
E100T-G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
E1000-2-G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
G1000-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
G1K-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
ML100T-12 Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
ML-100X-8 Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
ML1000-2 Not Supported Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC3 IR 4/STM1 SH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC3IR/STM1SH 1310-8 Not Supported Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17
OC12 IR/STM4 SH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 LR/STM4 LH 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 LR/STM4 LH 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC12 IR/STM4 SH 1310-4 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17 Fully Compatible, Slots 1–4, 14–17
OC48 IR/STM16 SH AS 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC48 LR/STM16 LH AS 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC48 ELR/STM16 EH 100 GHz Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13 Supported in Slots 5–6, 12–13
OC192 SR/STM64 IO 1310 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC192 IR/STM64 SH 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC192 LR/STM64 LH 1550 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC192 LR/STM64 LH ITU 15xx.xx Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
OC192SR1/STM64I O Short Reach, OC192/STM64 Any Reach1 Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
MRC-12 Not Supported Not Supported Not Supported Not Supported Fully Compatible Fully Compatible
TXP_MR_10G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
MXP_2.5G_10G Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible
FC_MR-4 Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible Fully Compatible

1 These cards are designated as STM64-XFP in CTC.

JRE Compatibility

The following table shows ONS15454 SDH Software compatibility with various JRE versions.

ONS Software Release JRE 1.2.2 Compatible JRE 1.3 Compatible JRE 1.4 Compatible JRE 5.0 Compatible
ONS 15454 SDH Release 3.3 Yes Yes No No
ONS 15454 SDH Release 3.4 No Yes No No
ONS 15454 SDH Release 4.0 1 No Yes No No
ONS 15454 SDH Release 4.1 No Yes No No
ONS 15454 SDH Release 4.5 No Yes No No
ONS 15454 SDH Release 4.6 No Yes Yes No
ONS 15454 SDH Release 4.7 No Yes Yes No
ONS 15454 SDH Release 5.0 No No Yes No
ONS 15454 SDH Release 6.0 No No Yes No
ONS 15454 SDH Release 7.0 No No Yes Yes

ONS 15454 SDH CTM/NE Software Compatibility

This table shows ONS15454 SDH software compatibility with CTM.

NE Software Version CTM Software Version
R3.30.0x(3.3) CTM R3.1,3.2
R3.40.0x(3.4) CTM R3.2,4.0,4.1,4.6
R4.0.0x (4.0) CTM R4.0,4.1,4.6, 4.7
R4.1.0x(4.1) CTM R4.1,4.6, 4.7
R4.6.0x(4.6) CTM R4.6, 4.7
R5.0.0x (5.0) CTM R5.0, 6.0
R6.0.0x (6.0) CTM R6.0

Related Information

Updated: Nov 18, 2004