Field Notice: FN - 62419 - Catalyst 6500 Supervisor Engine 32 Running in Hybrid IOS Mode May Fail to Forward Traffic - Software Upgrade Required


May 26, 2006

NOTICE:

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.


Products Affected

Product

Comments

C6000 - WS-SUP32-GE-3B

Only hybrid mode is affected - CatOS versions earlier than 8.4(3) and MSFC versions earlier than 12.2(17d)SXB9 and 12.2(18)SXF

C6000 - WS-SUP32-GE-3B=

Only hybrid mode is affected - CatOS versions earlier than 8.4(3) and MSFC versions earlier than 12.2(17d)SXB9 and 12.2(18)SXF

CATOS - 8.4(3)

Versions earlier than 8.4(3) are affected

IOS - 12.2(17d)SXB9

Versions earlier than 12.2(17d)SXB9 are affected

IOS - 12.2(18)SXF

Versions earlier than 12.2(18)SXF with the exception of {12.2(17d)SXb9 or later} are affected

Problem Description

There is an initialization issue that may result in partial or total loss of conectivity for packets sourced by the inband, SC0 interface or the MSFC VLAN interfaces. This issue affects Supervisor Engine 32 in Hybrid IOS mode only.

Background

Customers running a Catalyst 6500 with a Supervisor Engine 32, may experience loss of connectivity to or from the SC0 interface of the supervisor and/or the VLAN interfaces of the MSFC. This is caused by a defect in the software initialization routines on this specific supervisor.

Supervisor Engines running in Native IOS mode are not affected by this issue. For software dependencies refer to the individual sections of this Field Notice.

Problem Symptoms

If the customer is running a supervisor image that has this software defect fixed (8.4(3) or later) but is running an MSFC image that is still impacted (earlier than 12.2(17d)SXB9 or earlier than 12.2(18)SXF), the following error message will be displayed:

Error message:

2006 Mar 01 01:06:04 %SYS-1-MOD_MSFC_FAILONLINE:MSFC Module 16 FAILED to come ONLINE 
2006 Mar 01 01:06:04 %SYS-1-MOD_MSFC_INCOMPATIBLEIMAGE:MSFC Module 16 Image Upgrade
Required to support Inband Port ASIC present in System 

If the customer is running a supervisor image that is impacted by this defect (earlier than 8.4(3)) and any MSFC image (impacted or not) no error message will be displayed, although loss of connectivity can be observed.

Workaround/Solution

Upgrade the Supervisor to CATOS release 8.4(3)or later versions, and for MSFC IOS release (also known as Hybrid) to 12.2(17d)SXB9 or 12.2(18)SXF or later versions.

DDTS

To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.

DDTS

Description

CSCse22998 (registered customers only)

Loss of Connectivity from NMP sc0 interface or MSFC Vlan interface.

Cisco IOS Versions Affected

  • CATOS release 8.4(2a) and earlier versions.

  • MSFC IOS release (Hybrid) 12.2(17d)SXB8 and earlier versions.

  • MSFC IOS release (Hybrid) earlier than 12.2(18)SFX

Note: 12.2(18)SXF is not affected.

Revision History

Revision

Date

Comment

1.0

26-MAY-2006

Initial Public Release