Field Notice: FN - 61902 - SPA-2GE-7304: Low Voltage Warning on 1.2V Rail


Revised October 25, 2005
November 16, 2004


NOTICE:

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.

Products Affected

Product Top Assembly Printed Circuit Assembly
Part # Rev. Part # Rev.
SPA-2GE-7304 68-2206-02 A0 73-8792-04 A0

Problem Description

The SPA-2GE-7304 has been identified with having a resistor that allows voltage to drop below tolerance.

This only pertains to the 68-2206-02 version stipulated in the Products Affected section of this field notice.

Background

The cause of the SPA-2GE-7304 voltage warning message (environmental monitor) is due to a faulty resistor and is hardware related.

This field notice will deal with voltage drops caused by the faulty Trim resistor thus causing the 1.2V rail to trim to 1.0V.

It is also possible for sporadic SPA packet drops to be experienced under the conditions of a lower voltage output, namely if the 1.2V power supply goes below or above the allowed range (0.984V - 1.416V) and could dip below the shutdown threshold causing the IOS to shutdown the SPA-2GE-7304. IOS running on the SPA-2GE-7304 regularly monitors various voltage rails on the board. Should any of those rails fall under or over preset thresholds, IOS will issue a WARNING or a CRITICAL messages.

Problem Symptoms

Below is an example of an output logging displayed:

%ENVM-2-CRITICAL: card in 4/1, SPA-2GE-7304 1.2V voltage measured at 1.003V

Note: The slot/final voltage may vary, when type inputing the following command manaully.

To identify the offending SPA you may execute the following IOS command:

sh env all
Card in subslot 2/0:
SPA-2GE-7304 1.8V measured at 1.807 V
SPA-2GE-7304 1.5V measured at 1.504 V
SPA-2GE-7304 2.5V measured at 2.486 V
SPA-2GE-7304 3.3V measured at 3.246 V
SPA-2GE-7304 1.2V measured at 1.003 V:Voltage in Critical range!

Workaround/Solution

Workaround:

None

Solution:

Customers that have a SPA-2GE-7304 (version 68-2206-02 only) can use the standard RMA process to have their card replaced.

Product ID Version
SPA-2GE-7304 68-2206-01
SPA-2GE-7304 68-2206-03

How To Identify Hardware Levels

Use the show diagnostic command as illustrated below in order to determine what Rev the SPA-2GE-7304 is. For the sake of this example Rev 1 is shown and highlighted in bold :


#show diag subslot 4/1
Subslot 4/1:
Shared port adapter: 2xGE SPA, 2 ports
Info: hw-ver=0x200, sw-ver=0x0 fpga-ver=0x0
State: ok
Insertion time: 00:13:48 ago
Bandwidth: 2000000 kbps
EEPROM contents:
EEPROM version : 4
Compatible Type : 0xFF
Controller Type : 1078
Hardware Revision : 2.0
Boot Timeout : 400 msecs
PCB Serial Number : JAB082506M2
PCB Part Number : 73-8792-03
PCB Revision : B0
Fab Version : 03
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Deviation Number : 74255
Product Identifier (PID) : SPA-2GE-7304
Version Identifier (VID) : V01
Top Assy. Part Number : 68-2206-01
PCB Revision : B0
System Clock Frequency : 00 00 00 00 00 00 00 00
00 00 00 00 00
CLEI Code : CNUIAA1AAA
Base MAC Address : 00 00 00 00 00 00
MAC Address block size : 0
Manufacturing Test Data : 00 00 00 00 00 00 00 00
Field Diagnostics Data : 00 00 00 00 00 00 00 00
Calibration Data : Minimum: 0 dBmV, Maximum: 0 dBmV
Calibration values :
Power Consumption : 160000 mWatts (Maximum)
Environment Monitor Data : 01 08 F6 48 43 34 F6 48
43 34 02 31 04 B0 B4 A0
8C 00 00 05 DC 64 46 32
00 00 07 08 64 46 32 00
00 09 C4 64 46 32 00 00
0C E4 64 46 32 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 FE 02 F2
A9
Asset ID :
Asset Alias :
EEPROM contents (hex):
0x000: 04 FF 40 04 36 41 02 00 46 01 90 C1 8B 4A 41 42
0x010: 30 38 32 35 30 36 4D 32 82 49 22 58 03 8A 42 30

....

0x1E0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x1F0: FF FF FF FF FF FF AA FF FF FF FF FF FF FF FF FF
FPGA version:
Software version : 4.18
Hardware version : 4.18